HomeMy WebLinkAbout20200 71st Ave Ne_BLD2121_2026 CITY OF ARLINGTON
238 N. OLYMPIC AVE -ARLINGTON, WA. 98223
PHONE; (360) 403-3551
BUILDING PERMIT
Address:20200 71st Avenue NE Permit#:2121
Parcel#:00769800000300 Valuation: 168429.00
OWNER APPLICANT CONTRACTOR
Name:RHINO VENTURES Name:Sound Roof Services Name:Sound Roof Services,Inc.
Address:20100 71 ST AVE NE Address:]8908 Hwy 99 Address: 19808 Hwy 99,Suite B
City,State Zip:ARLINGTON,WA 98223-7447 City,State Zip:Lynnwood,WA 98036 City,State Zip:Lynnwood,WA 98036
Phone: Phone:425-672-4730 Phone:425-672-4730
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Name: Name:
Address: Address:
City,State,Zip: City,State,Zip:
Phone: Phone:
LIC#: EXP: LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Commercial Re-Roof CODE YEAR: 2015
STORIES: CONST.TYPE:
DWELLING UNITS: OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;
NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S
COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRCI10.
SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form
and coded City )f Arlington#3101.
-�
Signalftre Print Name Date Released By DAG
CONDITIONS
Call for Inspections.
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION
ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
9/5/2018 Processing/Technology Fee $25.00
9/5/2018 Re-Roof $1,996.95
Total Due: $2,021.95
Total Payment: $0.00
Balance Due: $2,021.95
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
_..
I
• ,.,
I
rrjGt'� 3�!6
Permit Information
Date 8/27/2018
Permit Number 2121
Project Name AMT
Applicant Name Sound Roof Services
Applicant Address 18908 Hwy 99
City,State,Zip Lynnwood,WA 98036
Contact Brian Storey
Phone 425-672-4730
Email brian@soundroofservices.com
Permit Type Commercial Re-Roof
Site Address 20200 71 st Avenue NE
Valuation 168429.00
Status Applied
Permit Issued
Permit Expires
Square Feet 0
Type of Construction/Occupancy Load
Number of Stories 0
Proposed Use Commercial re-roof with partial tear-off
Assigned To Kristin Foster
Property
Parcel Address Legal Owner Owner Phone Zoning
0076980QOOp300 120200 71ST AVE NE 1RHINOVENTURES 1637 Warehousing&Storage Services
Contractors
Contractor Name Primary Contact Phone Email Contractor Type License License#
Sound Roof Services,Inc.03rian Store 425-672-4730 rian soundroofservices.com ONTRACTOR Labor and Industries'3OUNDRS932J3
Review
Date Type Description Target Date Completed Date Assigned To Status
3/27/2018 Re-Roof 3/4/2018 Ouilding Pn Review
Uploaded Files I Upload File
Date File 77= Uploaded B
8/27/2018 1:42:24 PM JZ121 Application and Specs.pdf Foster.Kristin
r -.
1
I
i
RE-ROOF
PERMIT APPLICATION
Department of Community& Economic Development
City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360) 403-3551
Type of permit:
'ry(c(heck one) 1 ( ) Residential Commercial Valuation: 9
Project Address:181%_1 �00 30ALO71"UMAxflf)t0`HW0WAParcel ID#:
Owner: 9 n%UA d V 42 M-y1 f e S L L.C ) ,/�
Address: llpaeox eaq;l � City:,�i,16iM..Ll G� State: ,_fA Zip Code:
Phone Number: ws_ , a q,J go) Email: yll�}10I'Lva vQtkttkfe 3 tLAe.}I
A <
Applicant:_ Roo 52v"V1GC� �, In,--
Address: �g�Q X W:4 .f��/tJ�P7�/tl City:1c 11 J�lllrjDLf/�� State: Wp Zip Code:
Phone Number: yt 7�' %���L,� Email: br,1G14�1/C3�- />itP
Contractor:
Address: City: State: Zip Code:
Phone Number: pp Email:
Contractor's License Number: Sou D S—I.� .�2 Expiration:
Type of Roofing Material:Cat-l1S1e 04 z>r1a��al��' Number of Existing Layers: LA
Class Class of Roofing: A ® B ❑ C ❑ Replacing existing sheathing: Yes ❑ No
cof tear off: ❑ Application over existing material:
����leu{'o�iThe fol owiis requi for NON-Residential Buildings: 'l �'
• Existing roof structure and material: !6A N-4LfILOA0 ) VP,0141 sa tM L1W rP-0L4 _lF+q M&4 jT)ed
• Two copies of the installation specifications and U.L.listed roof assembly. }+k
• Occupancy of Building: Office Z oa4-1 v
Retail
Church
Restaurant
School
trn a 0 M Pit e-ra `itq
I hereby certify the above information is correct and that the construction o nd the occupancy and the use of the above described
property will be accordance with the laws, rules and regulations of the State of Washington. The applicant will be responsible for
providing a method of safely accessing roof for inspection. A final inspection and approval shall be obtained when the re-roofing is
complete.
&44(VL
Applicants Signature Date
Print Applicants _J
N
FOR STAFF USE ONLY Received
AUG 0 9 2018
Permit# A pled By Amount Received Receipt# Date Received
Q
r
N
�J
N
-dr :
LLJ
-7t"%-
• _, 4 ' _ -+ter:,,. � + w -
�4.
low Home : Espanol Contact "IMENN&E-
La' b'o'r : Industries
COSafety&Health Claims&Insurance c Workplace Rightso Trades&Licensing IM
Washington State Department of
Labor & industries
SOUND ROOF SERVICES INC
Owner or tradesperson 18908 HWY 99 STE B
Principals LYNNWOOD,WA 98036
206-672-4730
STOREY,BRIAN D,PRESIDENT SNOHOMISH County
■ WILLIAMS,MICHAEL JAMES,VICE
PRESIDENT
Doing business as
SOUND ROOF SERVICES INC
WA UBI No. Business type
602 709 020 Corporation
Governing persons
BRIAN
DOUGLAS
STOREY
MIKE JAMES WILLIAMS;
License
Verify the contractor's active registration/license I certification(depending on trade)and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
ROOFING
License no.
SOUNDRS932J3
Effective—expiration
04/23/2007—05/01/2019
Bond
DEVELOPERS SURETY 8,INDEM CO $12,000.00
Bond account no.
746471C
Received by L&I Effective date
04/23/2007 04/17/2007
Expiration date
Until Canceled
Insurance
Continental Insurance Co $1,000,000.00
Policy no.
5084577283
Received by L&I Effective date
04/06/2018 04/17/2014
Expiration date
04/17/2019
Insurance history
Savings Help us , _
I
. _� ��
'f
_ i
�'�
i
No savings accounts during the previous 6 y period. ;
Lawsuits against the bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&1 Tax debts
No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts
may be recorded by other agencies.
License Violations
No license violations during the previous 6 year period.
Workers' comp
Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums.
L&I Account ID Account is current.
133,584-00
Doing business as
SOUND ROOF SERVICES INC
Estimated workers reported
Quarter 2 of Year 2018"11 to 20 Workers"
L&I account contact
T2 I KATHY ULRICH(360)902-4829-Email:WITE235@lni.wa.gov
Public Works Strikes and Debarments
Verify the contractor is eligible to perform work on public works projects.
Contractor Strikes
No strikes have been issued against this contractor.
Contractors not allowed to bid
No debarments have been issued against this contractor.
Workplace safety and health
No inspections during the previous 6 year period.
A"Washington«
1
EXPERIENCE THE CARLISLE DIFFERENCE
srrvr�c srs�'�rn.•s
Sure-71ex"' PVC
Membrane
Fully Adhered Roofing System
The fully adhered system starts with a suitable surface upon which the
Low-VOC PVC Bonding Adhesive or Hydragond-Water-Based PVC Bonding
Adhesive is applied.
Mechanically Fastened Roofing System
The mechanically fastened system starts with approved insulation
being fastened with a minimum of 5 fasteners per 4'x 8'board.The
PVC membrane is then mechanically fastened to the deck using HP-X-
Fasteners and Piranha Plates",or HP-XTRA Fasteners and Piranha
XTRA Plates.Adjoining sheets of PVC membrane are overlapped over
the fasteners and plates and joined together with a minimum IYz"-wide
hot-air weld.
Review Carlisle specifications and details for complete installation
information.
Overview
Carlisle's Sure-Flex PVC is an advanced-formula,heat-weldable PVC Precautions
thermoplastic membrane that is designed for long-term weatherability and » Sunglasses that filter out ultraviolet light are strongly recommended.as
performance.The physical properties of the membrane are enhanced by a the membrane's white surface is highly reflective to sunlight.Roofing
tenacious,weft-inserted polyester fabric that is encapsulated by thick PVC- technicians should dress appropriately and wear sunscreen.
based top and bottom plies.The smooth surface of the PVC membrane , Smooth surfaces may cause slippery conditions due to frost and ice
allows for a total-surface fusion and permanent weld,creating a consistent, buildup.Exercise caution during cold conditions to prevent falls.
watertight,monolithic roof assembly.PVC can be used in adhered and
I Care must be exercised when working close to a roof edge when
mechanically fastened systems.The gray-colored bottom ply provides a surrounding area is snow-covered,as the roof edge may not be
visual confirmation of a proper weld during the lap welding process.
clearly visible.
Features and Benefits Use proper stacking procedures to ensure sufficient stability of the
» Wide choice of membrane sizes,thicknesses and colors materials.
» Enhanced chemical resistance » Exercise caution when walking on wet membrane.Membranes may be
» Energy efficiency
slippery when wet.
» Store PVC membrane in the original undisturbed plastic wrap in a
Wide window of weltlability cool,shaded area and cover with light-colored,breathable,waterproof
» Flexibility in low temperatures tarpaulins.PVC membrane that has been exposed to the weather or
u Impact and puncture resistance contaminated with dirt must be prepared with PVC Membrane Cleaner
» UV,ozone and oxidation resistance CITY OF ARLINGTON
» Easy installation BUILDING DEPARTMENT
» Available in white,gray,and tan APPROVED
Installation DATE BY GO
With minimal labor and few components required,PVC is quirk;md easy to -Received
install.PVC systems are installed using an Automatic Heat Welder,making NO CHANGES AUTHORIZED
sheet welding fast,clean and consistent. UNLESS APPROVED BY THE A I G ® 9 2018
BUILDING INSPECTOR
800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntee.com
EXPERIENCE
• '
sure-Flex PVC
Membrane
TypicalProperties • Characteristics Radiative for R•
• ■ • Co • "
Physical Property ASTM 04434 50-rill 60-rill 30-mil
Requirement _ White Tan Gray
Thickness over scrim,in.(nim) 0.016 min 0.022 0,027(0.686) 0.037 Physical Property Test Method PVC PVC PVC
ASTM D4434 optical method (OAO) (0-559) (D,940)
average of areas ENERGY STAR-E-903 Solar Spectrum 0.86 0,73 0.59
weight,Ibsnt°(kgtm') No requirement 0.33 (1.61) 0.40 (1.95) os5 Initial Solar Reflectometer
(2,68) Reflectance
Breaking strength Imn x co),Mile 275 min 320 x 300 330 x 300(So U8 x 3311 ENERGY STAR-E-903 Solar Spectrum 0.63 Pending Pending
RN.m)AS1M 0751 grab method (48) (56 x 53) x 55) (63 x 58) Solar Reflectance after Reflectometer
Elongation hank of relnhnce nenl(M) 25 ruin 30 x 30 30 x 30 30 x 30 3 years (Uncleaned)
(CD),%ASTM(1751 grit)mntlm0
roaring strongih 1MD x r,Dl,Ibt IN) 90 nho too x 120 10o x 130 100 x 132 CRRC- ASTM C1549 0.86 0.73 0.59
ASTM 0751 pros.0,8[if.x 8 in. (4001 (445 x 5341 (445 x 57M (445 x 5871 Initial$niar
Low temperature bend,ASTM PASS PASS PASS PASS Reflectance
02135,no cracks SA at-4010 (-40°C) (40"c) (-401C)
Linear CRRC- ASTM C1549 0.63 0.60" 0.48'
012046houslat176*Fnal nge,%ASTM -_0.5max 0.4 0.4 0.4 Solar Reflectance
01204,6 hours at t76"F (uncleaned)
Ozone resistance,no cricks 7x ASTM I PASS PASS PASS PASS after 3 years
Dt149,100pphm,168 firs CRRC- AS I M C 1311 0.89 0.86 0.85
Water absorption resistance,mass% t3.0 max 2.0 20 2.0 Initial Thermal
ASTM D570,166 hours at 150"F water Emittanre
Field seam strength,VAR,(kN/m) No requirement 2S(d.4)min 25(4 4)min 25(4-4)min L'RRC- ASTM C7371 0.87 0.82' 0.81'
ASTM 01876 tested in pool 60110.5) 60(10-5)ryp. 60(1G.51
ryp- typ Thermal Emdtance (uncleaned)
Water vapor permeance,Perms, No requirement 0.10 nlax 0.10 max O.10 max after 3 years
ASTM E96 proc.8 0,05 typ 005 typ 0,05typ Solar Reflective Index ASTM E1980 108 89 69
Puncture reslslanco-Federal,lot(kN) No requirement 280 320 380 (SRI)
FTM 101C,method 2031 I
Puncture resistance-Dynamic,J 20(14.7) PASS PASS PASS Solar Reflective Index ASTM E1980 75 70' 53,
(It-lift)ASTM 05635 (SRI)SRI after 3 years
Puncture resistance-Static,Hit(N) 33(146) PASS PASS PASS
ASTM D5602 Rapid Ratings
Xenon-Arc resistance,no PASS PASS PASS PASS
crackslcrazing 10x,ASTM GIGS
0.35 W/m'at 340-0m,63°C 8.P.T. I s Information
12,600 kJlm1 total radiant exposure
10,00a hours Pre-consumer Recycled Content 10%
Properties altar heat aging 90 min 90 min 90 min 90 min -
ASTM 03045,56 days at 17611' 90 min 90 min 90 min 90 min Post-Consumer Recycled Content 0%
greakltion roing(t1,%rained Manulacturin Location Greenville,IL
Elongalibn raiM.,%retained g
Typical properties and characleristics are based on samples tested and are not guaranteed for ailSolar Reflectance Index(SRI),Initial White:108.Tan:89,Gray:69
samples of this product-This data and Information Is intended as a guide and does not reflect the
specification range for any particular property of this product. Supplemental Approvals, Statements
and Characteristics
' n Sure-flex PVC meets or exceeds the requirements of ASTM D4434
Standard Specification for Poly(Vinyl Chloride)Sheet Roofing.Sure-Flex
s PVC is classified as Type III and/or Type IV as defined by ASTM 04434.
Sure-Flex reinforced PVC was tested for dynamic puncture resistance
per ASTM D5635-04 using the most recently modified impact head-
_ ....�..�..____,.. 3TA0 50-mil thick membrane was watertight after an impact energy of 22.5 J
(16.6 ft-lbf),which passes the ASTM D4434 requirement.
ri » Sure-Flex reinforced PVC was tested for static puncture resistance per
ASTM D5602-98 and exceeded 33 Ibf(145 N),which passes the ASTM
04434 requirement.
800-479-6832 1 P.O.Box 7000 i Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntec.com
11.29.17(0 2017 Cadlsle Carlisle,HydroRend Sure-Flex,HP-X Fasteners and Piranha Plates am IrademaMs of Cadlc!e
REPRINT CODE:605245 "Sure Flex PVC Membrane Producl Data Shea!" ENERGY STAR is a reglstered trademarx owned by the U 5 Government.'ENERGY STAR qualification is only valid in the U.G
LEED is a registered Iradenark of the U 5 Green 0uddino Council
EXPERIENCE THE CARLISLE DIFFERENCE
SecurShield"' HD POLYIS®
Insulation
Product Characteristics
pp-pppppPanel sizes:
- 4'x 8'(1220 mm x 2440 mm)
q 4'x4'(1220mmx1220mm)
r.� Panel thickness:Y?(13 mm)
�a Weight; 0.343 Ibs/sq.ft.
11 Ibs(4.99 kg)per 4'x 8'panel
5.5 Ibs(2.49 kg)per 4'x 4'panel
�-s Installation
Mechanically Attached Single-Ply Systems
Each SecurShield HD panel must be secured to the substrate with approved
Overview Carlisle fasteners and plates.Butt edges and stagger joints of adjacent
panels.Install the roof membrane according to Carlisle specifications.
Carlisle's SecurShield HD Pnlyiso Insulation is a rigid roof insulation
panel composed of a high-density,closed-cell polyisocyanurate foam Fully Adhered Single-Ply Systems
core laminated to a premium-performance,coated glass facer(CGF). Carlisle's SecurShield HD may be secured to the roof deck using Carlisle's
Suitable for both re-roofing and new construction applications, FAST"and Flexible FAST adhesive,01yBond500rP'insulation adhesive,
SecurShield HD is specifically designed fnr use as a cover board over a fasteners and plates,or hot asphalt(appropriate to the deck type)-
variety of substrates.SecurShield HD delivers an R-value of 2.5, which For adhesive coverage or fastening patterns and requirements,please
is significantly higher than roof cover boards made with other materials contact Carlisle's Design Services group. Butt the edges of the insulation
such as wood fiber or gypsum. panels and stagger the joints.Install the membrane according to Carlisle
Features and Benefits specifications,
Review Carlisle specifications and details for complete installation
N High-density insulating cover board information,
» Exceptional protection against hail,rooftop traffic,mold,and moisture
High-density formulation achieves FM severe hail rating(SH) bodes and Compliances
»2 times higher R-value than wood fiber hoards ASTM C1289,Type II,Class 4,Grade 1 (109 psi max.)
»
» Compatible with all Carlisle single-ply roofing systems(Except Ballast) International Building Code(IBC)Section 2603
n Coated glass facer provides strong bond for adhered roofing applications UL Standard 790,263 and 1256:Component of Class A Roof Systems(refer to UL Roof Materials'system directory)
FM Standards 4450/4470:Class 1 approval for steel roof-deck
Productivity Boosting Features and Benefits: constructions(refer to FM RoofNav)
Lightweight and easy to cut,handle,and » Caiifomia Codes of Regulations,Title 2.4,Insulation Quality Standard
install-no crumbling of material License 9TI-1418
7 5 times higher R-value than gypsum cover _ n Third-party certification with PIMA Quality Mark for Lang-Term
boards Thermal Resistance(LTTR)values
p %s the weight of gypsum cover boards ' CAN/ULC S704,Type 3,Class 2 Received
Florida Building Code Approval
AUG 0 9 2018
800-479-6832 1 P.O.Sox 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 ; www.carlislesyntee.com
EXPERIENCE
♦ CARLISLE
DIFFERENCE -
.SY{V7-EG ,4YSTEM
SecurShield HD POLYISO
Insulation
Precautions
Insulation must be protected from open flame and kept dry at all times.Install Typical
only as much insulation as can he covered the same clay by completed roof- Physical Property Test Method Value
covering material.Carlisle will not he responsible for specific building and compressive strength ASTM 01621 109 psi max
roof design,for deficiencies in construction or workmanship.for dangerous Dimensional Stability ASTM 02126 <0.5%linear change
conditions on the lobsite,or for improper storage and handling.Technical (7 days)
specifications shown in this literature are intended to be used as general water Absorption_ ASTM C209 <1 IN,volume
guidelines only and are subject to change without notice.Call Carlisle for R-value ASTM C518 2.5
more specific details or refer to PIMA Technical Bulletin No. 109:Storage and Thickness
Handling Recommendations for Polyiso Roof Insulation.
Service Temperature 260°F(126°C)or less
Resistance to Maid ASTM D3273 Passed
Typical properties and characteristics are based on samples tested and are not guaranteed
for all samples of this product This data and information is intended as a guide and does not
reflect the specification range for any particular property of this product.
LEEDI Information
Pre-consumer Recycled Content 0%
Post-consumer Recycled Content : 9%
Manufacturing Locations Smithfield,PA
Franklin Park,IL
Tooele,UT
Montgomery,NY
Lake City,FL
Terrell,TX,
Puyallup,WA
Solar Reflectance Index(SRI) N/A �� w
04 11.1A 0201G Canisle. 800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislasynlec.com
REPRINT LODE:GG5D75-`SacarShleld Ili)Polyisa Pmducl Dala Sheer" Canisle,SeGUIShreiA.Helrlele FAST and FAST are trademarks of Cadisle
Oly9ond500 Is a registered trademark al 0MG.LEED IS a registered trademark of the U.S-Green Building Council
EXPERIENCE
/ CARLISLE
DIFFERENCE '
H PA Fastener
Precautions
n The strength of different roof decks varies widely and ran be adversely
affected by moisture and other conditions.Therefore,Carlisle
AAA recommends conducting a fastener pull test to help evaluate deck
conditions and fastener suitability.
MCare must be taken not to overdrive the fastener.
Eye protection is recommended during drilling and installation.
�'Packaging Information
Size Weight/Carton Thread Length Packaging
Inches(mm) (Kg) Inches(mm) Fasteners/Carton
2(50) 20 Ibs(9.08) Full 1,000
3(75) 291bs(13,16) Full 1,000
Overview 4(100) 381bs(17.25) 3(76) 1,000
Carlisle's HP-X Fastener is a specialized,high performance fastener 5(125) 24lbs(10.89) 4(102) 500
designed to secure Carlisle single-ply membrane and insulation.The 6(150) 28lbs(12.71) 4(102) 500
HP-X Fastener can be used on steel decks(20-gauge[0,91 mm]or 7(175) 34lbs(15.44) 4(102) 500
22-gauge[0.76 mmj or wood[minimum 15/az"[12 mml CDX plywood]).
The HP-X Fastener is designed to offer an optimum combination of 8(200) 38Ibs(17.25) 4(102) 500
driving performance,back-out,and corrosion resistance with excellent 9(230) 42 ibs(19.07) 4(102) 500
pull-out performance. 10(255) 47lbs(21.33) 4(102) 500
11 (280) 52 Ibs(23.61) 4(102) 500
Features and Benefits 12(305) 561bs(25.42) 4(102) 500
A Oversized heavy shank and#15 thread diameter for enhanced 14(355) 32 Ibs(14.52) 4(102) ?.50
pull-out resistance
16(405) 38 Ibs(1725) 4(102) 250
Miniature drill point penetrates decks quickly and contributes to
exceptional resistance to back-out as well as pull-out
Deep buttress threads further increase pull-out and back-out Typical Properties
resistance
Head 43 Phillips Truss Head
» Excellent corrosion resistance,surpassing the FM4470 corrosion test .435"(11.04 mm)diameter
Thread 265"(6.73 mm)diameter
Installation Shank .202"(5,13 mm)diameter
1. No pre-drilling is necessary for wood and steel decks.Simply insert coaling CH-110
the HP-X Fastener through an approved Carlisle plate and install
Typical properties and characteristics are based on samples tested and are not guaranteed
with a standard clutch drive electric screw gun(0-2,500 rpm). for all samples of this product.This data and information is intended as a guide and does not
2. Optimum fastener performance is achieved when the fastener is reflect the specification range for any particular properly of[his product.
installed perpendicular to the deck and into the top flutes of a steel
deck.
Review Carlisle specifications and details for complete installation Received
information.
AUG 0 9 M8
��721Z1
800-479-6832 1 P.0 Box 1000 1 Carlisle, PA 17013 1 Fax:717-245-7053 1 www.carlislesyntee.com
0114,16 t 2O16 Carhsle Carlisle,Sure-Weld and Sure-Flex are lradenrarks of Carlisle
WES ONLY:CSi-7O66"HPA Fastener Product Onta Sheet'
EXPERIENCE THE CARLISLE DIFFERENCE
SYNTSC SYSTEMS
Sure-Flex"' PVC
Low-VOC Bonding Adhesive
Application
I. The surface on or against which adhesive is to be applied shall
be clean,smooth,dry,free of fins,sharp edges,loose and foreign
materials,oil and grease,Depressions greater than�/4"(6 mm)
should be feathered using epoxy,mortar or other approved patching
material.All sharp projections shall be removed by sweeping,
blowing or vacuum cleaning.
2. After thorough stirring(minimum 5 minutes),apply PVC tow-VOC
Bonding Adhesive to substrate and membrane using a 9"(229 mm)
1 medium nap roller.Application shall be continuous and uniform,
° r avoiding globs or puddles.An open time of 5 to 50 minutes(based
on drying conditions)is recommended before assembly.PVC Low-
VOC Bonding Adhesive must be allowed to dry until it does not string
or stick to a dry finger touch.The membrane and substrate will be
dry(non-tacky)to the finger touch.Any coated area that has been
Overview exposed to rain should be allowed to dry and then recoated.Do not
Sure-Flex PVC Low-VOC Bonding Adhesive is a high-strength solvent- apply adhesive to splice areas to be hot-air welded.
based contact adhesive that allows bonding of PVC and KEE membranes 3. Roll the membrane onto the adhesive-coated substrate while
to various porous and non-porous substrates.It is specially formulated avoiding wrinkles.Immediately brush down the bonded portion
using a blend of VOC-exempt and non-exempt solvents to be in compliance of the sheet with a soft-bristle push broom or a clean dry roller
with the state of California Clean Air Act of 1988(updated in 1997)and applicator to achieve maximum contact.
as further regulated by California's Air Quality Control Districts listing
Review Carlisle specifications
VOC limitations.This product also meets the<250 gpl VOC content fications and details for complete application
requirements of the OTC Model Rule for Single-Ply Roofing Adhesives. information.
Features and Benefits precautions
• High-strength adhesive that allows quick bonding Review the applicable Material Safety Data Sheet for complete safety
information prior to use.
• Can be easily applied with a medium nap roller PVC Low-VOC Bonding Adhesive is EXTREMELY FLAMMABLE.It
• Provides excellent adhesion between various substrates and PVC contains solvents that are dangerous fire and explosion hazards when
and/or KEE membranes exposed to heat,flame or sparks.Do not smoke while applying.Do not
use in a confined or unventilated area.Vapors are heavier than air and
Coverage Rate use
travel along ground or may be moved by ventilation and ignited by
60 112(5.6 m2)per gallon finished surface.Coverage rates are average and pilot lights,other flames,sparks,heaters,smoking,electrical motors,
may vary due to conditions on the jobsite.Porous surfaces and substrates static discharge,or other ignition sources at locations distant from
may require more bonding adhesive than the typical coverage rate. material handling point.All containers should be grounded when material
is transferred from one container to another.A red caution label is
Mixing required when shipping.A fire extinguisher should be available.In case
Stir thoroughly until the adhesive is uniform in color.Minimum 5 of fire,use water spray,foam,dry chemical or carbon dioxide.Do not
minutes stirring is recommended. use a solid stream of water because it can scatter and spread the fire,
r Avoid breathing vapors.Keep container closed when not in use.
Use with adequate ventilation.If inhaled,remove to fresh air. If not
breathing,perform artificial respiration.If breathing is difficult,give
oxygen.Call a physician immediately.During application,efforts must
800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislasyntec.com
EXPERIENCE ME CARLISLE DIFFERENCE AYX=j Ig
SYNTEC, SYS 7 Ears
Sure I ex PVC
Low-VOC Bonding Adhesive
be made to prevent fumes from entering the building via air ventilation Typical Properties and Characteristics
ducts.Do not place open containers or mix adhesive near fresh air
intake units.When possible,shut down or seal off the closest units. Base Synthetic rubber
If swallowed,DO NOT INDUCE VOMITING.Call a physician immediately. Color Pale yellow to orange to amber
n Avoid contact with eyes.Safety glasses or goggles are recommended. Solids 23.6-29.6%
If splashed in eyes,immediately flush eyes with plenty of clean water Flash Point -4°F(-20°C)SETA
for at least 15 minutes.Contact a physician immediately. Brookfield Viscosity 1500-4500 centipoises
n Avoid contact with skin.Wash hands thoroughly after handling.In case Average Net Weight 6.9-7.7 Ibs/gal(0.8—0.9 kgA)
of contact with skin,thoroughly wash affected area with soap and packaging 5-gal pail
water_Contact physician if irritation persists. Shelf Life 1 year
Note:Permeation-resistant gloves(that meet ANSI/ISEA 105-2005) Typical properties and characteristics are based an samples tested and are riot guaranteed
are recommended to be warn when using this product to protect hands for all samples of this product.This data and intormatlan is intended as a guide and does not
from irritating ingredients. reflect the specification range for any particular property of this product.
Do not thin PVC Low-VOC Bonding Adhesive-Thinning will affect
performance.Excessively thick or gelled material should be discarded. LEEDI Information
U Jobsite storage in excess of 90'F(32°C)may affect product shelf life. Pre-consumer Recycled Content 0%
Should the PVC Low-VOC Bonding Adhesive be stored at temperatures Past-consumer Recycled Content 0%
lower than 60'F(15'C),restore to roam temperature priorto use.
VOC Content <250 g/I
n Opened containers of PVC Low-VOC Bonding Adhesive should be used Manufacturing Location Carlisle,PA
within 48 hours,Adhesives will begin to thicken after this point,making
it difficult and eventually impossible to control applied thickness.In hot
weather,do not leave sealed containers on roof for prolonged periods
of time.In cold weather,keep material at room temperature until ready
to use_Stir adhesive occasionally while using.
Adhesive must be allowed to dry thoroughly.If membrane is mated
with the substrate prior to the adhesive being dry,blistering will occur
and will not subside over time.
KEEP OUT OF REACH OF CHILDREN,
Received
AUG 0 9 2018
Wr7 7,124
800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.Garlislesyntec.com
09-21.13®2013 Carlisle, Carlisle and Sure-Flex are trademarks of Carlisla
nEPDINTC,ODE:605666-"Sure-Flex PVC Low-VOC Bonding Adhesive Product Data Sheet' LEED is a registered trademark of fire U.S.Green Building Council
EXPERIENCE THE CARLISLE DIFFERENCE .�
SYNTEc -YSTkFNFF,
Sure—Flex"' PVC Cortilied
Fabricated y
Coated Metal Accessory
Installation
1 Install Sure-Flex PVC Coated Metal with a%"to;,4" (3-6 mm)gap
between adjoining sections.
2. Install 2"(5 cm)-wide foil tape over joints.
3. Heat-weld a 6"(15.5 cm)-wide piece of Sure-Flex PVC Flashing
over each joint.
4. Position Sure-Flex PVC membrane and heat-weld to the Sure-Flex
PVC Coated Metal with a minimum 1t/2" (4 cm)weld.
Review Carlisle specifications and details for complete installation
information.
Precautions
» Store Sure-Flex PVC Coated Metal in a cool,shaded area,and cover
with light-colored,breathable,waterproof tarpaulins.Sure-Flex PVC
Coated Metal that has been exposed to the weather must be prepared
Overviews with Carlisle's PVC Membrane Cleaner prior to hot-air welding.
Carlisle's Sure-Flex PVC Coated Metal is a galvanized steel sheet with a » Do not install Sure-Flex PVC Coated Metal in such a way that the
laminate of non-reinforced Sure-Flex PVC flashing.The sheet is cut into membrane side is in direct contact with asphalt,coal tar pitch,
the appropriate width and used to fabricate metal drip edges or other polystyrene,or other petroleum-based products.
roof perimeter edge profiles.Sure-Flex PVC membrane may be welded
directly to the coated metal,eliminating the need to strip in the metal with
Characteristics
a separate piece of membrane.The metal is available in 4-foot by 10-footProperties '
(1.2 m by 3.1 m)sheets and comes packaged 10 sheets per pallet. Sheet Sae 4 foot by 10 foot(1.2 in by 3.0 m)
Carlisle's Sure-Flex PVC Coated Metal is part of the Certified Fabricated weight 1.1 Ib/Itz(5.4 kg/mz)
Accessory(CFA)program.Certified Fabricated Accessories are the Color White,Gray and Tan
only factory-fabricated PVC accessories that meet the stringent quality Flashing Thickness 0.035 inches(0.9 mm)nominal
tolerances required to be included in a Carlisle warranted roofing system. Steel Thickness 0-024 inches(0.6 mm)nominal(24 gauge)
PVC coated aluminum and stainless steel are available in 4'x 10'sheets on —
a special order basis in white,gray,and tan.Contact customer service for Steel Type Ilot Dipped Galvanized Steel—GOO
minimum orders and lead times. Packaging 10 sheets per pallet
Typical properties and characteristics are based on samples tested and are not guaranteed
Features and Benefits for all samples of this product.This data and information is intended as a guide and does not
reflect the specificabon range for any particular property of this product.
» Allows direct welding of Sure-Flex PVC membrane to the coated metal,
eliminating the need to strip in edging with additional membrane
Easy to cut and form to Create a variety of edge sizes and profiles EED11 Information
» Practical and cost-effective way of flashing roof edges Pre consumer Recycled Content j 0%
,,Available in white gray,and tan colors Post-consumer Recycled Content mya
n Manufacturing Location Scranton,PA
» Matches membrane color to create a uniform look
Solar Reflectance Index White:ll I
Gray:43
Tan:50
600-479-6a32 I P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntee.com
09.0R.1e 6 2016 CarOsle.
REPRINT CODE 605539-'Sure-Flex PVC Coaled Metal Product Data Sheol" Carlisle and Sure-Flex are trademarks at Carlisle
EXPERIENCE THE CARLISLE DIFFERENCE
Sure-Flex"' PVC �jertified
Molded Pipe Flashing Accessory
Installation
1. Cut Pipe Seal between double-ribbed cutting guides,one size
smaller than the pipe diameter. Do not cut off raised ring.
2. Pull Pipe Seal over pipe until base flange is in contact with the
membrane.It may be necessary to apply heat to the top portion of
the Pipe Seal to allow installation over the pipe.
3. Mark pipe around the top of the Pipe Seal.
4. Pull Pipe Seal upwards on pipe until mark on the pipe is visible.
5. Apply Universal Single-Ply Sealant below the mark that indicates the
top of the installed Pipe Seal.
6. Pull Pipe Seal back down over pipe and into position.
Overview 7. Heat-weld the Pipe Seal base flange to deck membrane.
8. Install a stainless steel universal clamping ring to provide constant
Carlisle's Sure-Flex PVC Pipe Seals are injection-molded,pre-formed compression of the sealant.
flashings for pipes.75"(19 mm)to 8"(203 mm)in diameter.This labor-
saving accessory provides a quick and reliable way to waterproof round Review Carlisle specifications and details for corrrplete installation pipe penetrations. information.
Sure-Flex PVC Pipe Seals are part of Carlisle's Certified Fabricated Precautions
Accessory(CFA)program.Certified Fabricated Accessories are the
only factory-fabricated PVC accessories that meet the stringent quality Remove all lead and other flashing.
tolerances required to be included in a Carlisle warranted roofing system. A Temperature of pipe must not exceed 140*F(60°C).
Install a minimum of four fastening plates around pipe penetrations.
Features and Benefits Position fastening plates around the penetration so they are covered by
Provides a reliable method of waterproofing round pipe penetrations the Pipe Seal flange.A minimum 1.5"-wide weld must be maintained
Provides substantial labor savings compared to field-fabricating from around the outer edge of the flange beyond the plates.If fastening
non-reinforced flashing plates cannot be installed in a manner to allow a minimum 1.5"weld,
the plates must be placed outside the Pipe Seal flange and covered
Provides a more consistent appearance than field-fabricated pipe with a reinforced Sure-Flex membrane overlay.
flashings
Store Pipe Seals in a cool,shaded area and cover with light-colored,
Double-ribbed cutting guide facilitates easier,smoother,and breathable,waterproof tarpaulins.Sure-Flex Pipe Seals or membranes
straighter cuts that have been exposed to the weather must be prepared with PVC
:y Rib design holds the clamp in the proper position Membrane Cleaner prior to hot-air welding.
Typical . •-
Productivity Boosting Features and Benefits: Sizes 3l4"to 8"O.D.Pipe(19 to 203 mm)
� Up to 60°le labor savings compared to Packaging 8 per box __.____.
traditional field fabrication ` r Weight(each) 0.55 Ibs(0,25 kg)
xi Quick and simple installation with no _ Material PVC compound Received
stretching required Color White,Tan,and Gray A l fir' q pp
b Provides a consistent,finished appearance ' ' i ` Typical properties and characteristics are bused on samples tested and are not q nranCe P '" 2 O 1 "
for all samples of this product.This data and informahon is intended as a guide and does not
reflect the specification range for any particular property of this product, LA
800-479.6832 1 RO.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carl isle syntec.cam
DIFFERENCEEXPERIENCE THE CARLISLE ta x=:f 4gr
sYjv-mac SYOT P40
Sure-Flex PVC
Molded Pipe dashing
Please use the chart below to cross-reference your pipe size with the proper step to cut as shown.
Copper • •
Nominal Tube Sae A" 1" 1 1A, 1 1k" 2" 2,hN 3' 401 5• 6" all
88 1 13 138 1.63 2,13 2.63 3.13 4.13 5.13 6.13 NIA
Step of Boat Used I 1 1 1 h 2 2 3 4 5 6 N/A
ScheduleI .1 Steel PipePVC Standard Polyethylene Pipe IPS
Nominal Tube Sae 2A" 1" 1 1/4" 1 112" 2" 2112" 3" 4" 5" 6" all
Pipe O.D. 1.06 1.32 1.66 1.90 2.38 2.88 3.50 4.50 5.56 6.63 8.63
Step of Boat Used 1 1 1 'h 1'k 2 3 3 4 5 6 B
Pipe
Pit Class A&Spun 100-250 Pit Class B,C&0
Nominal Tube Sae 2" 3" 4" 614 8" 2" 3" 4" o"" 8"
Pipe Q.D. 2.50 3.96 4.80 6.90 9.50 N/A 3.96 5.00 71n 9.30
Step of Boot Used 2 4 5 6 NIA N/A 4 5 6 NIA
Sewer - Soil Pipe
PVC Plastic SDR 35&41...Cast Iron Soil Pipe no hub..,service weight&extra heavy
Nominal Tube Sae 4" 4" 4„ 4" 6" 6" 6" 6" 8" 8„ 8" 8„
Pipe H. ' 4.22 4.38 4.30 4.62 6.28 6.30 6.30 6.62 8.40 8,38 8.38 8.75
Step of Boot Used _ 4 4 4 4 6 6 6 6 8 8 8 8
Conduit EMT
Nominal Tube Sire }- 34 1" 1 1/4" 1'/a" 2" 2 h" 3" 3 h„ 4"
Pipe O.D. -922 1.16 1.51 1.74 2.19 2.88 3.50 4.00 4.50
Step of Boot Used 1 1 I 116 2 3 3 4 4
Conduit
Nominal Tube Size 35" 1" 1114.. 1 1/2 2" 2 /2" 3" 3,,4" 4"
Pipe O.D. 1.02 1.29 1.63 1,88 2.36 2.85 3.47 3.97 4.46
Step of Boot Used 1 1 1 h 1 %i 2 3 3 4 4
Conduit Rigid
Nominal Tube Sae + A" 1" 1'M" 1 W" 2" 21h" 3" 3 1h" 4" 5"
Pipe O.D. 1 1.05 1.32 1.66 1.90 2.37 2.87 3.5- 4 4.5 5.56
Step of Boot Used 1 1 1 '1h 1 i6 2 3 3 4 4 5
800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntec.com
01.10,16®2016 Catlisle
REPRINT CODE:605152-'Sure-Flex Pipe Seals PrDduC!Oala Sheet" Carlisle and Sure-Flex are Irdderuarks of Carlisle
EXPERIENCE THE CARLISLE DIFFERENCE
SYNTEC 8Y'BT�M,S
gi 4 Azi Id
Sure-Flex... PVC Cortrlied
Inside Corners l A�G s�o '
Installation
1. Position the PVC Inside Corner into the comer,begin welding at the
i innermost corner point and work away from the corner.
2. Use the edge of the roller to crease the corner flashing into any
1 membrane step-off to create a proper seal.
1 3. Probe all welded edges of the corner once the material has been
completely cooled to ensure watertight performance.
Review Carlisle specifications and details for complete installation
information.
Precautions
Store PVC Inside Corners in a cool,shaded area and cover with light-
F colored,breathable,waterproof tarpaulins.PVC Inside Comers or PVC
membranes that have been exposed to the weather or contaminated
Overview with dirt must be prepared with PVC Membrane Cleaner prior to hot-air
Sure-Rex PVC Inside Corners are pre-molded and are used for flashing welding.
the inside comers on a variety of details. Installation is fast and easy with
no cutting or stretching required.This product is available in white,gray
and tan. _
Carlisle's PVC Inside Comers are part of the Certified Fabricated Accessory Thickness D6o"(1.52 mm)
(CFA)program.Certified Fabricated Accessories are the only factory-
fabricated PVC accessories that meet the stringent quality tolerances Packaging 12/bag
required to be included in a Carlisle warranted roofing system. Material Injection-molded non-reinforced PVC flashing
Color White,Gray and Tan
Features and Benefits
Forms easily into out-of-square corners that are not exactly 90 degrees LEEDI Information
p Provides substantial labor savings compared to field-fabricating Pre-consumer nemicted Content D46
the flashing detail from non-reinforced flashing Post-consumer Recycled Content 11'I
>3 More consistent appearance than inside corners field-fabricated Manufacturing Location Bloomingdale,IL
from flashing
Solar Reflectance Index(SRI) White:111
Gray:43
Tan:50
Received
AUG 09 ?018
12? ',
800-479-6832 1 P.D.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntee.cam
1122 13 0 2013 Carlisle Carlisle and Sure Flex are trademarks of Carlisle
REPRINT CODE:605146-'Sure-Flex PVC Inside Corners Product Data Sheet" LEED Is a registered trademark of the U S.Green Building Council
EXPERIENCE THE CARLISLE DIFFERENCE
/ •
—SYNITEO sY.s=A4--
S u re-F!ex"' PVC Cje,nned
T Fbbrccated
i-Joint Covers Accessory
Installation
1. If membrane has been exposed to the weather,clean splice
intersection area with PVC Membrane Cleaner.
2, Use a lower temperature setting on the heat welder than that used
for welding reinforced membrane.(Typically a setting of 6-7 on a
I I scale of 10 is appropriate for welding PVC T-Joint Covers.)
3. Center the PVC T-Joint Cover over the splice intersection,begin
welding at the center point and work towards the outside.Use the
edge of the roller to crease the PVC T-Joint Cover into membrane
step-offs to achieve a proper seal.
4. Once the weld area is completely cool,check all splices for voids
and cold-welds with a seam probe.Make any needed repairs.
Review Carlisle specifications and details for complete installation
information.
Overview
Sure-Flex PVC T-Joint Covers are used to seal step-offs at splice Precautions
intersections.Installation is mandatory on all 60-and 80-mil PVC systems The PVC T-Joint Cover is not intended for use to overlay fasteners and
and air 50-mil systems where step-offs have not been property sealed.PVC plates as this requires the use of reinforced membrane.
T-Joint Covers are formed from 60-mil white and 40-mil gray and tan non
reinforced PVC cut into a perfect 4.5"-diameter circle.Packaged in a box Store the PVC T-Joint Covers in a cool,shaded area and cover with
containing 100 covers.Available in white,gray and tan. light-colored,breathable,waterproof tarpaulins.PVC T-Joint Covers
that have been exposed to the weather prior to use must be prepared
Carlisle's PVC T-Joint Covers are part of the Certified Fabricated Accessory with PVC Membrane Cleaner before hot-air welding.
(CFA)program.Certified Fabricated Accessories are the only factory-
fabricated PVC accessories that meet the stringent quality tolerances Typical Properties
required to be included in a Carlisle warranted roofing system.
Saes 4.5"(114 mm)
Features and Benefits Thickness 0.060"(1.52 mm)White
0.040"(1.02 mm)Tan and Gray
u More consistent appearance than hand-cut flashing -
Packaging 1001box
u Provides substantial labor savings compared to field-cut T-Joint covers Weight(per box) 3.5lbs(1.6 kg)
> Provides a more professional appearance than field-fabricated covers Material Non-Reinforcer]PVC
Seals channels at splice intersections created by seam step-offs Color White,Gray and Tan
Typical properties and characteristics are based on samples tested and are not guaranteed
for all samples of this product This data and information is intended as a guide and does not
rellect the specification range for any particular property of this product.
LEEDI Information
Pre-consumer Recycled Content 0°/a
Post-consumer Recycled Content 0%
Manufacturing Location Eugene,OR
Bloomingdale,IL
Solar Reflectance Index(SRI) White:111
Gray:43
Tan:50
800-479.6832 1 PA.Box 7000 l Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntee.com
11.22,13 0 2013 Carllsle
Carlisle and Sure-Flex are trademarks of Carlisle
REPRINT C00F 005150-'Sure-Flex PVC T-Joint Covers Producl Data Sheer" LEFT)is a regislered trademark of the U.S Green Building council
EXPERIENCE
e ! RLISLE DIFFERENCE !•
SYSTiEMS
Sure-Flex"' PVC
Non-Reinforced Flashing
Precautions
h Review the applicable Safety Data Sheet for complete safety information
prior to use.
Sunglasses that filter out ultraviolet light are strongly recommended,as
white surfaces are highly reflective.Roofing technicians should dress
appropriately and wear sunscreen.
Store PVC Flashing in a cool,shaded area and cover with light-colored,
breathable,waterproof tarpaulins.PVC Flashing that has been exposed
to the weather for approximately 7 days or longer must be prepared
with PVC Membrane Cleaner prior to hot-air welding.
PropertiesTypical
Properties ASTM Test Method Specification
Overview Tolerance on nominal Thickness ASTM D751 .8
Carlisle's Sure-Flex PVC Non-Reinforced Flashing is a 60-mil thermoplastic Weight,Ib/1`12(kglm2),typical 0.44 Ib/ft2
polyvinyl chloride(PVC)membrane enhanced with KEE HP plasticizer for Breaking strength,min,Ibflin.(N) ASTM D751 Proc.B 167.60(MD),
increased longevity and enhanced performance.Available in white,gray, 142-88(CD)
and tan,PVC Flashing is offered in 12"and 24"by 50'rolls.When the use Elongation at Break,min.,% ASTM D751 Proc.B 399.60(MD),
of prefabricated accessories is not feasible,PVC Flashing can be used to 420.27(CD)
create inside and outside comers,field-fabricated pipe flashings,curb Tear strength,min.,Ibf/in(kN/m) ASTM D1004 10
corners,and scuppers.
Heat aging:28 days 9'.Retention ASTM 04434 90
Features and Benefits Resistance to Xenon-Arc weathering ASTM D4434 "No cracking/
-Xenon-Arc„5,040 kJ/m2 total crazing,
KEE HP enhances flexibility,making it easier to field-fabricate details radiant negligible
-Exposure,visual condition at 7X discoloration"
:> KEE HP increases weatherability for added protection at critical
transition areas and maximum longevity Typical properties and characteristics are based on samples tested and are not guaranteed
for all samples of this product.This data and information is intended as a guide and does not
» Superior weldability allows for consistent,high-quality seams in reflect the specification range for any particular property of this product.
penetrations and other critical roof areas
» Available in white,gray,and tan to match Carlisle's Sure-Flex PVC and LEEDO Information
KEE HP membranes
Pre-consumer Recycled Content 10%
Installation Post-consumer Recycled Content 0%
1. PVC Flashing is used to flash various roofing system details and Manufacturing Location Mountain Top,PA
penetrations.The specific installation method will vary based on Solar Reflectance Index 111(white),69(gray),81(tan)
the situation.
2. Use a lower temperature setting on the heat welder than when
welding non-reinforced PVC membrane.Typically,a setting of 7 on
a scale of 10 is appropriate for welding PVC Flashing. Received
3. Use the edge of the roller to crease the flashing into any membrane AUG �
step-offs for a proper seal. ll 0 9 ?0 1 8
Review Carlisle specifications and details for complete installation �jY�"/I �JV�l'
l
information.
800-479-6832 1 R0.Box 7000 i Carlislo,PA 17013 1 Fax:717-245-7053 I www.carlislosyntec.com
05 23 17 0 2017 Carlisle, Carllsle and SUM-FIeK are trademarks of Carllsie
REPRINT COM:600319-'Sure-Flex PVC Non-neinforred Flashing Product Data Sheet" LEFn is a registered trademark LA the U S Green Building Council
EXPERIENCE THE CARLISLE DIFFERENCE ta
Sure#-Flek' PVC �ertirle�
Fabric3t.d
Walkway Rolls Accessory
3. Using an automated welder,weld all four sides of the PVC Walkway
Roll to the membrane.(Typically the same speed and temperature
settings will be used for this procedure as for welding membrane to
membrane.A test weld is always recommended prior to performing
welds to the installed membrane.)A hand-held welder may be
utilized;however,productivity will be decreased.
Review Carlisle specifications and details for complete installation
information.
Precautions
num I -L VParnvrar nU115 are a Illdll llCllFAIIGe Ilelll a11U ale Ildl GUVered under
the Carlisle membrane systems warranty.
This product is to be used as a walkway only and is not designed as a
Overview perimeter warning line or a substitute for ballast.PVC Walkway Rolls
Carlisle's Sure-Flex PVC Heat Weldable Walkway Roll is designed to protect cannot be installed within 10'(3 m)of the roof perimeter.
the PVC membrane in those areas exposed to repetitive foot traffic and If possible,allow the PVC Walkway Roll to relax prior to welding in place.
other hazards.
The PVC Walkway Rolls provide a defined path to walk on for those Packaging
servicing and repairing HVAC systems and other rooftop equipment found Each roll individually bagged.Fourteen rolls per skid,
on low-slope roofs. Size:36"wide x 60'long(91.4 rm x 18.3 m)
Walkways must be installed at all traffic concentration points(i.e. Weight:95 Ibs(roll)
roof hatches,access doors,rooftop ladders,etc.)regardless of traffic Color:Gray
frequency.Walkways must also be installed if regular maintenance(once a Thickness:80 mils
month or more)is necessary to service rooftop equipment.
Carlisle's PVC Walkway Rolls are part of the Certified Fabricated Accessory Typical Properties • Chairacteristics
(CFA)program.Certified Fabricated Accessories are the only factory- Typical
fabricated PVC accessories that meet the stringent quality tolerances Physical Property Test Method Properties Maximum
required to be included in a Carlisle warranted roofing system. Minimum
Dimensional Conformance ASTM D412 0.072(1.83) 0,088(2.24)
Features and Benetits Thickness,in.(mm)
Increased slip resistance created with a diamond tread pattern Density,lbs./ft3(gr/cm3) ASTM 0792 80.5(1-29) 84.3(1.35)
Enhanced PVC formulation Tensile Strength,psi(MPa) ASTM D638 600(4.1)
Tear Strength,Ibflin(kN/m) ASTM D624 100(17.5)
Superior weathering package for long-term performance - -
Typical properties and characteristics are based on samples tested and are not guaranteed
Installation for all samples of this product.This data and information is intended as a guide and does not
reflect the specification range for any particular property of this product-
1- Use PVC Membrane Cleaner to prepare the membrane to be welded
to the walkway material. Information
2. Position the PVC Walkway Rolls. Cut the PVC Walkway Roils into Pre consumer Recycled Content 45%
maximum 10' lengths and position with a minimum 1"gap between —
adjacent pieces to allow for water drainage.Cut the PVC Walkway Post consumer Recycled Content 20%
Roll so a 4"minimum gap is created over any field splices.(As the Manufacturing Location Mountain Top,PA
attachment of the walkway to the membrane is permanent,this will Solar Reflectance Index(SRI) N/A
_allow accesstto the field seams.)
800-479-6832 i P.0-Box 7000 1 Carlisle, PA 17013 I Fax:717-245-7053 ; www.carlislosyntec.com
01.20.14 s-2014 cadlsle varllsle and Sure-Flex are trademarks of Carlisle
REPAINT CODE:605536-'Sure-Flex PVC Walkway Rolls Product Data Sheet" LEER is a registered trademark of the If S-Green Building Council
R E-ROOF
PERMIT APPLICATION
°" Department of Community& Economic Development
City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403--3551
Type of permit: (check one) 't ( ) Residential Commercial Valuation: 8 /M` ®
Project Address: )� � ' I� �C� 'xy��7�r 1't N�ftf1,�`)�,(�!}�Parcel ID#:
Owner: 'A G L�� \ri.1�c?S , L 1.L ,, �
Address: P P a eox call a city:5.1.�Gtvinti►S tl t S ''
State:� Zip Code:q��4
Phone Number: `1 _h-�c�o�(�' LCL� Email:-M ��G>> 7 yet�fitnC�5 , b�le_t
Applicant: �,\� �c?OT SC�V Uc1�C� S t l oz Address: i ggC?1� W,1 qq�} SG JIJfe—f7 City: '! 't " '' 64 State: `laJ`r Zip Code: e7f ®_l b
Phone Number: Email: i 1l�Ul �i Ltltct ��^�c>�_��l�i/iG�Lz,:f� lbt
Contractor: ��L
Address: City. State: Zip Code:
Phone Number: nn Email:
_)
Contractor's License Number:-, G n T►= 9 Expiration:
Type of Roofing Material: Grxr�l�ln ��tL i �Ls+���Al�l e Number of Existing Layers:
Class of Roofing: A ® B ❑ C ❑ Replacing existing sheathing: Yes ❑ No
oof tear off: ❑ Application over existing material:
The following is recidifor NON-Residential Buildings:
• Existing roof structure and material: b)(;10A Qw_ C ���n{�, --�� �411�i;�n j�,l j�,t)a-t loo; 3-4[i AC��)ed
�Q c
• Two copies of the installation specifications and U.L.listed roof assembly.
• Occupancy of Building: Office Zoo I [
Retail
Church
Restaurant
School
frylCtvtytTrJtG�ilr`ibt�
I hereby certify the above information is correct and that the construction o nd the occupancy and the use of the above described
property will be accordance with the laws, rules and regulations of the State of Washington. The applicant will be responsible for
providing a method of safely accessing roof for inspection. A final inspection and approval shall be obtained when the re-roofing is
complete.
Applicants Signature Date
� l V, -S
Print Applicants N
FOR STAFF USE ONLY ReceiveM
?� _ _ AUG 0 9 2018
Permit J1 Ac pied By Amount Received Receipt# Date Received
f f �.•: 'r 1'T �, ;� -.�'�'l1�ri��'�'j 1' - � r�.�!fy4Nr�fir.*'Y'
1
Z '
a�
w
N
v �
•
•law
EXPERIENCE THE CARLISLE DIFFERENCE
S re l ex'" PVC
Membrane
Fully Adhered Roofing System
The fully adhered system starts with a suitable surface upon which the
Low-VOG PVC Bonding Adhesive or HydroBond-Water-Based PVC Bonding
Adhesive is applied.
� T
Mechanically Fastened Roofing System
The mechanically fastened system starts with approved insulation
i being fastened with a minimum of 5 fasteners per 4'x 8'board.The
PVC membrane is then mechanically fastened to the deck using HP-X-
Fasteners and Piranha Plates—,or HP-XTRA Fasteners and Piranha
XTRA Plates.Adjoining sheets of PVC membrane are overlapped over
the fasteners and plates and joined together with a minimum 1Yz"-wide
hot-air weld.
Review Carlisle specifications and details for complete installation
information.
Overview
Carlisle's Sure-Flex PVC is an advanced-formula,heat-weldable PVC Precautions
thermoplastic membrane that is designed for long-term weatherability and » Sunglasses that filter out ultraviolet light are strongly recommended,as
performance.The physical properties of the membrane are enhanced by a the membrane's white surface is highly reflective to sunlight.Roofing
tenacious,weft-inserted polyester fabric that is encapsulated by thick PVC- technicians should dress appropriately and wear sunscreen.
based top and bottom plies.The smooth surface of the PVC membrane » Smooth surfaces may cause slippery conditions due to frost and ice
allows for a total-surface fusion and permanent weld,creating a consistent, buildup.Exercise caution during cold conditions to prevent falls.
watertight,monolithic roof assembly.PVC can be used in adhered and
mechanically fastened systems.The gray-colored bottom ply provides a Care muss be exercised when working close to a roof edge when
visual confirmation of a proper weld during the la welding surrounding area is snow-covered,as the roof edge may not be
P p 9 p g process. clearly visible.
Features and Benefits n Use proper stacking procedures to ensure sufficient stability of the
Wide choice of membrane sizes,thicknesses and colors materials_
Enhanced chemical resistance Exercise caution when walking on wet membrane.Membranes may be
slippery when wet.
� Energy efficiency
Store PVC membrane in the original undisturbed plastic wrap in a
ll Wide window of weldability cool,shaded area and cover with light-colored,breathable,waterproof
» Flexibility in low temperatures tarpaulins.PVC membrane that has been exposed to the weather or
Impact and puncture resistance contaminated with dirt must be prepared with PVC Membrane Cleaner
u UV,ozone and oxidation resistance prior to clot-air welding.
n Easy installation
u Available in white,gray,and tan
Installation
With minimal labor and few components required,PVC is quick and easy to Received
install.PVC systems are installed using an Automatic Heat Welder,making
sheet welding fast,clean and consistent. AUG ® q 2018
800-479-6832 1 P.0_Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntee.com
EXPERIENCE
1 DIFFERENCE
'
sYhrr�� sus i sn�as
Sure-Flex PVC
Membrane
Typical Properties and Characteristics 1 Radiative Properties for ENERGY STARO*, ..
Physical Property I ASTM 04434 50-rail 60-rail 80-rail Roof RatingCouncil . , `
Requirement __ _ White Tan Gray
Thicknessoverscnm,in.(nun) 0.016min 0-022 0.027(0,686) 0,037 Physical Property Test Method PVC PVC PVC
ASTM D4434 optical method (0.40 (0,940)
average of 3 areas ) (0.559) ENERGY STAR-E-903 Solar Spectrum 0.86 0.73 0.59
Welght,Ibsttt2(kghn7) No requirement 0.33 (1.61) 0.40 (1,95) 0,55 Initial Solar Reflectometer
(2.68) Reflectance
Breaking 6treuglh(MD x CD),flit/In 275 min 320 x 300 330 x 300(So 360 x 330 ENERGY STAR-E-903 Solar Spectrum 0.63 Pending Pending
(kN/m)ASTM D751 grab method (48) (56 x 53)__x 55) _ (63 x 58) Solar Reflectance after Reflectometer
Elangatlon break of reinfurcement(MD 25 min 30 x 3g 30 x 30 30 x 30 3 years (Uncleaned)
_x CD),%ASTM D7- grab method _
Tearing strength(MD x CD),Ibf(N) 90 min 100 x 120 100 x 130 100 x 132 CRRC- ASTM C1549 0.86 0.73 0.59
ASTM 0751 pros.B,8 In x 81n. (400) (445 x 534) (445 x 578) (445 x 587) Initial Solar
Low temperature bead,ASTM PASS PASS PASS PASS Reflectance
02135,no cracks 5xat-40°C (-401C) (-40oc) (40113)
Unear - CRRC- ASTM C1549 0.63 0.60' 0.48`
01204 dimensionalchange,%ASTM m0.5 max 0.4 0.4 Solar Reflectance
D1204,6 hours att176"P t1.A (Uncleaned)
Ozone resistance,no cracks 7x ASTM PASS PASS PASS PASS after 3 years
D1149,100pphm,168 hrs CRRC- ASTM C1371 0.89 0.86 0.85
Water absorption resistance,mass% ±3.0 max 2.0 20 ?_A Initial Thermal
ASTM D570,166 hours at 156^F xater Emittanre
Reid soam strength,mflln.(kN/m) No reanaremnnl 25(4.4)min 25(4.4)min 25(4,41 min CRRC ASTM C1371 0.87 0.82` 0.81'
ASTM 01676 tested in peel 60110.51 Go(10.5)typ, 60 it 0.51
typ _ typ. Thermal Emittance (uncleaned)
Water vapor permeance,Perms, No requirement 0.10 max 0.10 max OAD max after 3 years
ASTM E96 proc B 0.05 typ 0.05 typ 0.05 typ Solar Reflective Index ASTM E1980 108 89 69
Puncture reslstanco-Federal,lbf(kN)i No requirement 260 320 380 (SRI)
FTM 101C,method 2031
Puncture resistance-Dynamic,J 20(14.71 PASS PASS PASS Solar Reflective Index ASTM E1980 75 70' 53'
(N-Ib0 ASTM 05635
(SRI)SRI after 3 years
Puncture resistance-Static,Ibf IN) 33(145) PASS PASS PASS
ASTM D5602 Rapid Ratings
Xenon-Arc resistance,no i PASS PASS PASS PASS
cracks?crazing lox,ASTM G155
0.35 Wrm'at 340-nm,63°C B.P.T. LEED Information
12,600 kJyml total radiant exposure
10,000hOtirs _ Pre-consumer Recycled Content 10%
Properties after heat aging 90 min 90 min 90 min 90 min l -
ASTM D3045,56 daysat 176°F 1 90 min 90 min 90 min 90 min Post-consumer Recycled Content 0%
Bongalgstroird., %retained Manufacturing Location Greenville,IL
FJongalian rairll.,%retained 9
Typical properties and characteristics are based an samples tested and are not guaranteed for all Solar Reflectance Index(SRI),Initial White:108,Tan:89,Gray:69
samples of this product.This data and information is intended as a guide and does not reflect the
specification range for any particular property of this product. Supplemental Approvals, Statements
and Characteristics
D Sure-Flex PVC meets or exceeds the requirements of ASTM D4434
Standard Specification for Poly(Vinyl Chloride)Sheet Roofing.Sure-Flex
PVC is classified as Type III and/or Type IV as defined by ASTM D4434.
» Sure-Flex reinforced PVC was tested for dynamic puncture resistance
per ASTM D5635-04 using the most recently modified impact head.
50-mil thick membrane was watertight after an impact energy of 22.5 J
(16.6 ft-)bf),which passes the ASTM 04434 requirement.
>1 Sure-Flex reinforced PVC was tested for static puncture resistance per
ASTM D5602-98 and exceeded 33 Ibf(145 N),which passes the ASTM
1 D4434 requirement.
800-479.6832 I P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntec.com
11.29.11 T3 2017 Carlisle. Carlisle.HydroRond."sure-Flex,HP-X F.uteri and Piranha Plates are trademarks of Carlisle
REPAINT CODE:605245.'Sure Flex PVC Membrane Product Data Sheet" ENERGY STAR is a registered trademark awned by the US Govemment.*ENERGY STAR qualification is only valid in the US
LEED is a registered Trademark of the U S Green Oulluri Councll
11 '.-lecurShield' HD POLYISO
Insulation
-qqqN Product Characteristics
pppppppPanel sizes:
- 4'x 8'(1220 mm x 2440 min)
4'x 4'(1220 min x 1220 mm)
* Panel thickness:Y2'(13 mm)
Weight: 0.343 Ibs/sq.ft,
11 Ibs(4.99 kg)per 4'x 8'panel
5.5 Ibs(2.49 kg)per 4'x 4'panel
Installation
Mechanically Attached Single-Ply Systems
Each SecurShield HD panel must be secured to the substrate with approved
Overview Carlisle fasteners and plates.Butt edges and stagger joints of adjacent
panels.Install the roof membrane according to Carlisle specifications.
Carlisle's SecurShield HD Fnlyiso Insulation is a rigid roof insulation
panel composed of a high-density,closed-cell polyisocyanu rate foam Fully Adhered Single-Ply Systems
core laminated to a prernium-performance,coated glass facer(CGF). Carlisle's SecurShield HD may be secured to the roof deck using Carlisle's
Suitable for both re-roofing and new construction applications, FAST`"and Flexible FAST adhesive, UiyBond500r11 insulation adhesive,
SecurShield HD is specifically designed for use as a cover board over a fasteners and plates,or hot asphalt(appropriate to the deck type).
variety of substrates.SecurShield HD delivers an R-value of 2.5,which For adhesive coverage or fastening patterns and requirements,please
is significantly higher than roof cover boards made with other materials contact Carlisle's Design Services group. Butt the edges of the insulation
such as wood fiber or gypsum_ panels and stagger the joints. Install the membrane according to Carlisle
Features and Benefits specifications.
Review Carlisle specifications and details for complete installation
» High-density insulating cover board information.
:> Exceptional protection against hail,rooftop traffic,mold,and moisture
;> High-density formulation achieves FM severe hail rating(SN) Codes and Compliances
n 2 times higher R-value than wood fiber hoards ASTM C1289,Type II,Class 4,Grade 1 (109 psi max.)
>�
» Compatible with all Carlisle single-ply roofing systems(Except Ballast) International Building Code(IBC)Section 2603
UL Standard 790,263 and 1256:Component of Class A Roof Systems
» Coated glass facer provides strong bond far adhered roofing applications (refer to UL Roof Materials'system directory)
FM Standards 4 4 5 014 47 0:Class 1 approval for steel roof-deck
Productivity Boosting Features and Benefits. constructions(refer to FM RoofNav)
Lightweight and easy to cut;handle,and » California Codes of Regulations,Title 24,Insulation Quality Standard
install-no crumbling of material License#TI-1418
» 5 times higher R-value than gypsum cover _ >> rhird-party certification with PIMA Quality Mark for Lang-Term
boards Thermal Resistance(LTTR)values
* Vs the weight of gypsum cover boards � r � CAN/ULC S704,Type 3,Class 2
Received
:} Florida Building Code Approval
AUG 0 9 HIS
�1b21zt
300-479-6832 1 R0.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntee.com
EXPERIENCEs
RLISLE DIFFERENCE loop;If-if
Sl'fVTEC SYSTFr\,r.
SecurShield HD POLYISO
Insulation
Precautions
Insulation must be protected from open flame and kept dry at all times.Install Typical Properties and Characteristics
only as much insulation as can be covered the same day by completed roof- Physical Property Test Method Value
covering material.Carlisle will not he responsible for specific building and Compressive Strength ASTM D162.1 109 psi max
root design,for deficiencies in construction or workmanship,for dangerous Dimensional Stability ASTM D2126 <0.5%linear change
conditions on the jobsite.or for improper storage and handling.Technical (7 days)
specifications shown in this literature are intended to be used as general Water Absorption ASTM C209 <1%volume
guidelines only and are subject to change without notice.Call Carlisle for R-value ASTM C518 2.5
more specific details or refer to PIMA Technical Bulletin No.109:Storage and Thickness Y2
Handling Recommendations for Polyiso Roof Insulation,
Service Temperature 260°F(1261G)or less
Resistance to Mold ASTM D3273 Passed
Typical properties and characteristics are based on samples tested and are not guaranteed
for all samples of this product.This data and information is intended as a guide and does not
reflect the specification range for any particular property of this product.
Information
Pre-consumer Recycled Content 0%
Post-consumer Recycled Content 9%
Manufacturing Locations Smithfield,PA
Franklin Park,IL
Tooele,UT
Montgomery,NY
Lake City,FL
Terrell,TX,
Puyallup,WA
Solar Reflectance Index(SRI) N/A
04 11 19®2alB Carlisle. 800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 I www.carlislesyntec.com
GaMft
HEPRINT CODE:605075-"SecurShleld UD Pelyiso Product Data Sheet" ulyBondSDG is a registered Imdemark at MI LEEp qhI HIM*FAST and FAST are trademarks ot canisle
lyESIM)Irademark al the D.S.Green Buiimnu.,aunt
DIFFERENCEEXPERIENCE THE CARLISLE s
SYr\1_rF0 SY 5T 7B
HPA Fastener
Precautions
n The strength of different roof decks varies widely and can be adversely
affected by moisture and other conditions.Therefore,Carlisle
recommends conducting a fastener pull test to help evaluate deck
conditions and fastener suitability.
Care must be taken not to overdrive the fastener,
Eye protection is recommended during drilling and installation.
InformationPackaging
Size Weight/Carton Thread Length Packaging
Inches(mm) (Kg) Inches(mm) Fasteners/Carton
2(50) 20 Ibs(9.08) Full 1,000
3(75) 29 Ibs(13.16) Full 1,000
Overview 4(100) 38 lbs(17,25) 3(76) 1,000
Carlisle's HP-X Fastener is a specialized,high performance fastener 5(125) 24lbs(10.89) 4(102) 500
designed to secure Carlisle single-ply membrane and insulation.The 6(150) 28 Ibs(12,71) 4(102) 500
HP-X Fastener can be used on steel decks(20-gauge[0.91 mmi or 7(175) 34 Ibs(15.44) 4(102) 500
22-gauge[0.76 mm]or wood[minimum 11/32"[12 mm]COX plywood]). - -
The HP-X Fastener is designed to offer an optimum combination of 8(200) 38 Ibs(17.25) 4(102) 500
driving performance,back-out,and corrosion resistance witti excellent 9(230) 42lbs(19.07) 4(102) 500
pull-out performance. 10(255) 47 Ills(21.33) 4(102) 500
11(280) 52 ibs(23.61) 4(102) 500
Features and Benefits12(305) 56 Ibs(25.42) 4(102) 500
» Oversized heavy shank and#15 thread diameter for enhanced 14(355) 32 Ibs(14.52) 4(102) ?5r!
pull-out resistance
16(405) 38 Ibs(17.25) 4(102) 250
Miniature drill paint penetrates decks quickly and contributes to
exceptional resistance to back-out as well as pull-out
Deep buttress threads further increase pull-out and back-out Typical Properties
resistance
Head #3 Phillips Truss Head
Excellent corrosion resistance,surpassing the FM4470 corrosion test .435"(11.04 mm)diameter
Thread .265"(6.73 mm)diameter
Installation Shank 202' (5.13 mm)diameter
1. No pre-drilling is necessary for wood and steel decks.Simply insert Coating CR-10
the HP-X Fastener through an approved Carlisle plate and install
Typical properties and characteristics are based on samples tested and are not guaranteed
with a standard clutch drive electric screw gun(0—2,500 rpm). for all samples of this product.This data and information is intended as a guide and does not
2. Optimum fastener performance is achieved when the fastener is reflect the specification range for any particular property of this product.
installed perpendicular to the deck and into the top flutes of a steel
deck.
Review Carlisle specifications and details for complete installation Received
information.
AUG 0 9 H18
- _.-
PArZ►zI
Amw
800-479-6832 I P.O. Box 7000 l Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntec.com
0714.16 0 7016 Carlisle, Carlisle,Sure-Weld and Sure-Flex are Irademarks of Carhsoe-
WEO ONLY:CS1-7066:"HP-x Fastener Product Data Sheet'
DIFFERENCEEXPERIENCE THE CARLISLE
SYrVTEC:, SY.STti+1�1S
Sure-Flex"' PVC
Low-VOC Bonding Adhesive
Application
I. The surface on or against which adhesive is to be applied shall
be clean,smooth,dry,free of fins,sharp edges,loose and foreign
materials,oil and grease.Depressions greater than W(6 mm)
should be feathered using epoxy,mortar or other approved patching
material_All sharp projections shall be removed by sweeping,
blowing or vacuum cleaning.
rswcr.�rr _ - 9 9
2. After thorough stirring(minimum 5 minutes),apply PVC Low-VOC
Bonding Adhesive to substrate and membrane using a 9"(229 mm)
p� medium nap roller.Application shall be continuous and uniform,
° avoiding globs or puddles.An open time of 5 to 50 minutes(based
on drying conditions)is recommended before assembly.PVC Low-
VOC Bonding Adhesive must be allowed to dry until it does not string
or stick to a dry finger touch.The membrane and substrate will be
dry(non-tacky)to the finger touch_Any coated area that has been
Overview exposed to rain should be allowed to dry and then recoated. Do not
Sure-Flex PVC Low-VOC Bonding Adhesive is a high-strength solvent- apply adhesive to splice areas to be hot-air welded.
based contact adhesive that allows bonding of PVC and KEE membranes 3. Roll the membrane onto the adhesive-coated substrate while
to various porous and non-porous substrates.It is specially formulated avoiding wrinkles.Immediately brush down the bonded portion
using a blend of VOC-exempt and non-exempt solvents to be in compliance of the sheet with a soft-bristle push broom or a clean dry roller
with the state of California Clean Air Act of 1988(updated in 1997)and applicator to achieve maximum contact.
as further regulated by California's Air Quality Control Districts listing Review Carlisle specifications and details for complete application
VOC limitations.This product also meets the<250 gpl VOC content
requirements of the OTC Model Rule for Single-Ply Hoofing Adhesives. information.
Features and Benefits Precautions
> High-strength adhesive that allows quick bonding Review the applicable Material Safety Data Sheet for complete safety
information prior to use.
» Can be easily applied with a medium nap rollerPVC Low-VOC Bonding Adhesive is EXTREMELY FLAMMABLE.It
» Provides excellent adhesion between various substrates and PVC contains solvents that are dangerous fire and explosion hazards when
and/or KEE membranes exposed to heat,flame or sparks.Do not smoke while applying.Do not
use in a confined or unventilated area.Vapors are heavierthan air and
Coverage Rate may travel along ground or may be moved by ventilation and ignited by
60 ft2(5.6 Wz per gallon finished surface.Coverage rates are average and pilot lights,otherflames,sparks,heaters,smoking,electrical motors,
may vary due to conditions on the jobsite.Parous surfaces and substrates static discharge,or other ignition sources at locations distant from
may require more bonding adhesive than the typical coverage rate. material handling point.All containers should be grounded when material
is transferred from one container to another.A red caution label is
Mixing required when shipping.A fire extinguisher should be available.In case
Stir thoroughly until the adhesive is uniform in color.Minimum 5 of fire,use water spray,foam,dry chemical or carbon dioxide.Do not
minutes stirring is recommended. use a solid stream of water because it can scatter and spread the fire.
Avoid breathing vapors.Keep container closed when not in use.
Use with adequate ventilation.If inhaled,remove to fresh air. It not
breathing,perform artificial respiration.If breathing is difficult,give
oxygen.Call a physician immediately.During application,efforts must
800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntee.com
EXPERIENCE CARLISLE DIFFERENCE
SY'NTEC SYSTF_�.sP.S
Sure-Flex PVC
Low-VOC Bonding Adhesive
be made to prevent fumes from entering the building via air ventilation Typical Properties and Characteristics
ducts.Do not place open containers or mix adhesive near fresh air
intake units.When possible,shut down or seal off the closest units. Base Synthetic rubber
a if swallowed,DO NOT INDUCE VOMITING.Call a physician immediately. Color Pale yellow to orange to amber
Sands 23.6-29.6%
n Avoid contact with eyes.Safety glasses or goggles are recommended.
If splashed in eyes,immediately flush eyes with plenty of clean water Flash Point -4°F(-20°C)SETA
for at least 15 minutes.Contact a physician immediately. Brookfield viscosity 1500—4500 centipoises
„ Avoid contact with skin.Wash hands thoroughly after handling.In case Average Net Weight 6.9-7.7 Ibs/gal(0.8—0.9 kq/l)
of contact with skin,thoroughly wash affected area with soap and Packaging 5-gal pail
water.Contact physician if irritation persists. Shelf Life 1 year
Note:Permeation-resistant gloves(that meet ANSI/ISEA 105-2005) Typical properties and characteristics are based on samples tested and are not guaranteed
are recommended to be worn when using this product to protect hands for all samples of this product.This data and informatian is intended as a guide and does not
from Irritating ingredients. reflect the specification range for any particular property of this product.
» Do not thin PVC Low-VOC Bonding Adhesive.Thinning will affect
performance.Excessively thick or gelled material should be discarded. LEEW Information
u Jobsite storage in excess of 90°F(32'C)may affect product shelf life. Pre-consumer Recycled Content 0%
Should the PVC Low-VOC Bonding Adhesive be stored at temperatures Post-consumer Recycled Content 0%
lower than 60'F(15°C),restore to room temperature prior to use.
UOC Content <250 g<I
n Opened containers of PVC Low-VOC Bonding Adhesive should be used Manufacturing Location Carlisle,PA
within 48 hours.Adhesives will begin to thicken after this point,making
it difficult and eventually impossible to control applied thickness.In hot
weather,do not leave sealed containers on roof for prolonged periods
of time.In cold weather,keep material at roam temperature until ready
to use-Stir adhesive occasionally while using,
> Adhesive must be allowed to dry thoroughly.If membrane is mated
with the substrate prior to the adhesive being dry,blistering will occur
and will not subside over time.
KEEP OUT OF REACH OF CHILDREN.
Received
AUG 0 9 2018
1��"IZI�I
800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7059 1 www.carlislesyntec.com
G9.2b13®201a Cadisle Carlisle and Sure-Flee are trademarks of Carlisk)
REPRINT CODE 6056Gri-"Sure-Flex PVC Low-VOC Bonding Adhesive Product Bata Sheet' LEED is a registered trademark of the u.5 Green Building Council
EXPERIENCE THE CARLISLE DIFFERENCE 1rJ#A;:f Af aF
SYNTEC SYSTEM r.S
Sure-Flex"' PVC Certified
Coated Metal Aceassary
Installation
I. Install Sure-Flex PVC Coated Metal with a W'to (3-6 mm)gap
between adjoining sections.
2. Install 2"(5 cm)-wide foil tape over joints.
3. Heat-weld a 6"(15.5 cm)-wide piece of Sure-Flex PVC Flashing
over each joint.
4. Position Sure-Flex PVC membrane and heat-weld to the Sure-Flex
PVC Coated Metal with a minimum 11/z"(4 cm)weld.
Review Carlisle specifications and details for complete installation
information.
Precautions
a Store Sure-Flex PVC Coated Metal in a coal,shaded area,and cover
with light-colored,breathable,waterproof tarpaulins.Sure-Flex PVC
Coated Metal that has been exposed to the weather must he prepared
Overview with Carlisle's PVC Membrane Cleaner prior to hot-air welding.
Carlisle's Sure-Flex PVC Coated Metal is a galvanized steel sheet with a " Do not install Sure-Flex PVC Coated Metal in such a way that the
laminate of non-reinforced Sure-Flex PVC flashing.The sheet is cut into membrane side is in direct contact with asphalt,coal tar pitch,
the appropriate width and used to fabricate metal drip edges or other polystyrene,or other petroleum-based products.
roof perimeter edge profiles.Sure-Flex PVC membrane may be welded
directly to the coated metal,eliminating the need to strip in the metal with
a separate piece of membrane.The metal is available in 4-foot by 10-foot Typical Properties '
Characteristics
(1.2 in by 3.1 m)sheets and comes packaged 10 sheets per pallet. Sheet Size 4 foot by 10 foot(1.2 m by 3.0 m)
Carlisle's Sure-Flex PVC Coated Metal is part of the Certified Fabricated weight 1.1 IblfV(5.4 kgfmz)
Accessory(CFA)program.Certified Fabricated Accessories are the Color white,Gray and Tan
only factory-fabricated PVC accessories that meet the stringent quality Flashing Thickness 0.035 inches(0.9 mm)nominal
tolerances required to be included in a Carlisle warranted roofing system. Steel Thickness 0.024 inches(0.6 mm)nominal(24 gauge)
PVC coated aluminum and stainless steel are available in 4'x 10'sheets on - - -
a special order basis in white,gray,and tan.Contact customer service for Steel Type Hot Dipped Galvanized Steel-G90
minimum orders and lead times. Packaging 10 sheets per pallet
Typical properties and characteristics are based on samples tested and are not guaranteed
Features and Benefits for all samples of this product.This data and information is intended as a guide and does not
reflect the specification range for any particular property of this product.
Allows direct welding of Sure-Flex PVC membrane to the coated metal,
eliminating the need to strip in edging with additional membrane
]3 Easy to cut and form to create a variety of edge sizes and profiles ° Information
u Practical and cost-effective way of flashing roof edges Pre-consumer Recycled Content 0%
Available in white,gray,and tan colors Post-consumer Recycled Content 0%
� Manufacturing Location Scranton,PA
Matches membrane color to create a uniform look
Solar Reflectance Index whde:111
Gray:43
Tan:50
300-479-6032 1 P.O.Box 7000 1 Carlisle, PA 17013 1 Fax:717-245-7053 1 www.carlislesyntec.com
09 0R.16 0 2016 Carlisle,
REPRINT CDnE;G05639-'Sure-Flex PVC Coated Metal Product Data Sheet" Carlisle and Sure Rex are trademarks of Carlisle
EXPERIENCE CARLISLE
DIFFERENCE
LM
.s�-nr•r�c .s�sr-�n.ra
re _ d ex PVC `jertlfied r
Molded Pi Fl i' Fpacic oesedy
t'� ���°�� fyccessory
Installation
1. Cut Pipe Seal between double-ribbed cutting guides,one size
smaller than the pipe diameter. Do not cut off raised ring.
2. Pull Pipe Seal over pipe until base flange is in contact with the
membrane.It may be necessary to apply heat to the top portion of
the Pipe Seal to allow installation over the pipe.
3. Mark pipe around the top of the Pipe Seal.
4. Pull Pipe Seal upwards on pipe until mark on the pipe is visible.
5. Apply Universal Single-Ply Sealant below the mark that indicates the
top of the installed Pipe Seal.
6. Pull Pipe Seal back down over pipe and into position.
Overview 7. Heat-weld the Pipe Seal base flange to deck membrane.
B. Install a stainless steel universal clamping ring to provide constant
Carlisle's Sure-Flex PVC Pipe Seals are injection-molded,pre-formed compression of the sealant.
[lashings for pipes.75"(19 mm)to 8"(203 mm)in diameter.This labor-
savin Review Carlisle specifications and details for complete installation
g accessn ry provides a quick and reliable way to waterproof round information.
pipe penetrations.
Sure-Flex PVC Pipe Seals are part of Carlisle's Certified Fabricated Precautions
Accessary(CFA)program.Certified Fabricated Accessories are the
only factory-fabricated PVC accessories that meet the stringent quality Remove all lead and other flashing.
tolerances required to be included in a Carlisle warranted roofing system. Temperature of pipe must not exceed 140oF(60'C).
» Install a minimum of four fastening plates around pipe penetrations.
Features and Benefits Position fastening plates around the penetration so they are covered by
Provides a reliable method of waterproofing round pipe penetrations the Pipe Seal flange.A minimum 1.5"-wide weld must be maintained
Provides substantial labor savings compared to field-fabricating from around the outer edge of the flange beyond the plates.If fastening
non-reinforced flashing plates cannot be installed in a manner to allow a minimum 1.5"weld,
the plates must be placed outside the Pipe Seal flange and covered
> Provides a more consistent appearance than field-fabricated pipe with a reinforced Sure-Flex membrane overlay.
(lashings
u Store Pipe Seals in a cool,shaded area and cover with light-colored,
Double-ribbed cutting guide facilitates easier,smoother,and breathable,waterproof tarpaulins.Sure-Flex Pipe Seals or membranes
straighter cuts that have been exposed to the weather must be prepared with PVC
» Rib design holds the clamp in the proper position Membrane Cleaner prior to hot-air welding.
Typical PropertiesP Characteristics
Productivity Boosting Features and Benefits: Sizes 3/4"to B"O.D.Pipe(19 to 203 mm)
Packaging 8 per box
Up to 60%labor savings compared to — -- —
traditional field fabrication ` , Weight(each) 0.55 Ibs(0.25 kg)
n Quick and simple installation with no Material PVC compound Received
stretching required ) Color White,Tan,and Gray
Provides a consistent,finished a Pp earance ' t ?ypical properties and characteristics are based Al.)on samples tested and are not suarnn�J 9 2018
Wall samples of this product This data and information is intended as a guide and does not
reflect the specification range for any particular property of this product. 112-At/2l 21
is � -I//�
800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.earlisiesyntec.com
EXPERIENCE
■ DIFFERENCE ' .
srrvrFc srsrsvrs
Sure-Flex PVC
Molded Pipe Flashing
Please use the chart below to cross-reference your pipe size with the proper step to cut as shown.
Copper • .
Nominal Tulle Size T '/e" l" 1 W. t 1h" 2` 21h" 3" 4u 5" 6" 8"
Pipe O.D. 88 1.13 1,38 1.63 2.13 2.63 3.13 4.13 5.13 6.13 N/A
Step of Boat Used I 1 1 1 1h 2 T2� 3 4 5 6 N/A
Schedule 40/80 Steel Pipe - PVC Standard - Polyethylene Pipe IPS
Nominal Tube Size 7A" 1" 1 1/4" 1 1h" 2" 21h" 3" 41' 5" 6" 8"
Pipe Q.D. 1.05 1.32 1.66 1.90 2.38 2.88 3.50 4.50 5.56 6.63 8.63
Step of Boot Used t 1 1 1h 1 'h 2 3 3 4 5 6 8
•-
Pit Class A&Spun 100-250 Pit Class B,C&0
Nominal Tube Size 2" 3" 4" 6" B. 2" 3" 4" 6" 8"
Pipe O.D ?`10 3.96 4.80 6.90 9.50 NIA 3.96 5,00 7.10 9.30
Step of Boot Used 2 4 5 G NIA N/A 4 5 6 NSA
Sewer - Soil • r-
PVC Plastic SDR 35&41...Cast iron Soil Pipe no hub...service weight&extra heavy
Nominal Tube Size 4" 4" 4" W. 6" 6" 6" 6" 8" 8" 811 8"
Pipe O.D. 1 4.22 4.38 4.30 4,62 6.28 6,30 6.30 6,62 8.40 8,38 8.38 8.75
Step of Boot Used 4 4 4 4 6 6 6 6 a 8 8 8
Conduit
Nominal Tube Size 3'4" 1" 1 1/d' 1,h" 2" 21h" 3" 3,h" 4"
Pipe O.D. .922 1,16 1.51 1.74 2.19 2.88 3.50 4.00 4.50
Step of Boot Used 1 t I 1 'i 2 3 3 4 4
Conduit IMC
Nominal Tube Size 1 1h" 2" 21/2 311 31/z" 4"
Pipe O.D. 1.02 1.29 11,63 1.88 2.36 2.85 3.47 3,97 4.46
Step of Boot Used 1 1 1 'h 1 'h ?_ 3 3 4 4
Conduit Rigid
Nominal Tube Size 3W 1° 1 1/n" 1 h" 2" 2 1h" 3" 31h" 4" 5"
Pipe O.D. I 1,05 1.32 1,66 1.90 2.37 2.87 3.5 4 4.5 5.56
Step of Boot Used 1 I 1 h 1 V2 2 3 3 4 4 5
I ..
800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntec,com
07 1 D,1II®2018 Carlisle
REPRINT CODE:605152 'Sure-Flex Pipe Seals Product Data Sheet" Carlisle and Sure-Flex are trademarks of Carlisie
EXPERIENCE
! CARLISLE
DIFFERENCE '
SYIV_rEC SYSTEMS
Sure-Flex"' PVC 6ertined
Inside Corners ,FAccessory
Installation
I. Position the PVC Inside Corner into the corner,begin welding at the
innermost corner point and work away from the corner.
2. Use the edge of the roller to crease the corner flashing into any
membrane step-off to create a proper seal.
3. Probe all welded edges of the corner once the material has been
completely cooled to ensure watertight performance.
Review Carlisle specifications and details for complete installation
informatlan.
Precautions
v Store PVC Inside Comers in a cool,shaded area and cover with light-
colored,breathable,waterproof tarpaulins.PVC Inside Corners or PVC
membranes that have been exposed to the weather or contaminated
Overview with dirt must be prepared with PVC Membrane Cleaner prior to hot-air
Sure-Flex PVC Inside Corners are pre-molded and are used forflashing welding.
the inside comers on a variety of details.Installation is fast and easy with
no cutting or stretching required.This product is available in white,gray
and tan.
Typical Properties and Characteristics PVC Inside Comers are part of the Certified Fabricated Accessory Thickness i .060"(1.52 mm)
(CFA)program.Certified Fabricated Accessories are the only factory-
Packaging 12/bag
fabricated PVC accessories that meet the stringent quality tolerances
required to be included in a Carlisle warranted roofing system. Material Injection-molded non-reinforced PVC flashing
Color White,Gray and Tan
Features and Benefits
�+ Forms easily into out-of-square comers that are not exactly 90 degrees LEEDO Information
Provides substantial labor savings compared to field-fabricating Pre-consumer Recycled Content 0%
the flashing detail from non-reinforced flashing Post-consumer Recycled Content 0%
More consistent appearance than inside corners field-fabricated Manufacturing Location Bloomingdale,IL
from flashing
Solar Reflectance Index(SRI) White:111
Gray:43
Tan:50
Received
AUK A ,, 2nI8
800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntec.com
11 22 13®2013 Cadlsle Carlisle and Sure-Flex are trademarks at Carlisle.
REPRINT CODE:605148-"Sure-Flex PVC Inside Corners Pmducl Data Sheel" LEED Is a registered trademark of the D S.Green Building Council
EXPERIENCE THE CARLISLE DIFFERENCE
SYNTEC SY;�.TEM..r-
Sure-Flex"' PVC Certltfed
Fabrlcated�
T—Joint Covers Accessory
Installation
1. If membrane has been exposed to the weather,clean splice
intersection area with PVC Membrane Cleaner.
2. Use a lower temperature setting on the heat welder than that used
for welding reinforced membrane.(Typically a setting of 6-7 on a
l scale of 10 is appropriate for welding PVC T-Joint Covers.)
3. Center the PVC T-Joint Cover over the splice intersection,begin
welding at the center point and work towards the outside.Use the
edge of the roller to crease the PVC T-Joint Cover into membrane
step-offs to achieve a proper seal.
4. Once the weld area is completely cool,check all splices for voids
and cold-welds with a seam probe.Make any needed repairs.
Review Carlisle specifications and details for complete installation
intom7ation.
Overview
Sure-Flex PVC T-Joint Covers are used to seal step-offs at splice Precautions
intersections.Installation is mandatory on all 60-and 80-mil PVC systems D The PVC T-Joint Cover is not intended for use to overlay fasteners and
and on 50-mil systems where step-offs have not been property sealed.PVC plates as this requires the use of reinforced membrane.
T-Joint Covers are formed from 60-mil white and 40-mil gray and tan non-
reinforced PVC cut into a perfect 4-5"-diameter circle.Packaged in a box " Store the PVC T-Joint Covers in a cool,shaded area and cover with
containing 100 covers.Available in white,gray and tan. light-colored,breathable,waterproof tarpaulins.PVC T-Joint Covers
that have been exposed to the weather prior to use must be prepared
Carlisle's PVC T-Joint Covers are part of the Certified Fabricated Accessory with PVC Membrane Cleaner before hot-air welding.
(CFA)program.Certified Fabricated Accessories are the only factory-
fabricated PVC accessories that meet the stringent quality tolerancesTypical _
required to be included in a Carlisle warranted roofing system-
Sizes 4.5"(114 mm)
Features and Benefits Thickness 0.060"(1.52 mm)White
0.040"(1.02 mm)Tan and Gray
» More consistent appearance than hand-cut flashing
Packaging 100/box
u Provides substantial labor savings compared to field-cut T-Joint covers Weight(per box) 3.5 Itis(1.6 kg)
> Provides a more professional appearance than field-fabricated covers Material Non-Reinforced PVC
r Seals channels at spline intersections created by seam step-offs Color White,Gray and Tan
Typical properties and characteristics are based on samples tested and are not guaranteed
for all samples of this product.This data and information is intended as a guide and does not
reflect the specificalion range for any particular property of this product.
LEED"Information
Pre-consumer Recycled Content + 0%
Post-consumer Recycled Content 0%
Manufacturing Location Eugene,OR
Bloomingdale,IL
Solar Reflectance Index(SRI) White:111
Gray:43
Tan:50
800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www,carlislesyntec.com
11 22.13 0 2013 Carlisle Carlisle and Sure Flex are trademarks of Carlisle
REPRINT CODE:605150-'Sure-Flex PVC T-Joint Covers Product Data Sheer' LEFD is a registered Irarlenurk of the 115 Green eruldurg Couuui
EXPERIENCE THE CARLISLE DIFFERENCE
131"PlITEc
Sa ire-Flex... PVC
Non-Reinforced Flashing
Precautions
r Review the applicable Safety Data Sheet for complete safety information
prior to use.
Sunglasses that filter out ultraviolet light are strongly recommended,as
white surfaces are highly reflective.Roofing technicians should dress
appropriately and wear sunscreen.
H Store PVC Flashing in a cool,shaded area and cover with light-colored,
breathable,waterproof tarpaulins.PVC Flashing that has been exposed
=" to the weather for approximately 7 days or longer must be prepared
with PVC Membrane Cleaner prior to hot-air welding.
t
TypicalProperties ane Characteristics
Properties ASTM Test Method Specification
Overview Tolerance on nominal Thickness ASTM D751 8
Carlisle's Sure-Flex PVC Non-Reinforced Flashing is a 60-mil thermoplastic Weight,Ib/ftl(kg/mz),typical 0.441b1ft7
polyvinyl chloride(PVC)membrane enhanced with KEE HP plasticizer for Breaking strength,min,Ibf/in.(N) ASTM D751 Proc.B 167.60(MD),
increased longevity and enhanced performance-Available in white,gray, 142.88(CD)
and tan,PVC Flashing is offered in 12"and 24"by 50'rolls.When the use Elongation at Break,min.,% ASTM 9751 Proc,B 399.60(MO),
of prefabricated accessories is not feasible,PVC Flashing can be used to 420.27(CD)
create inside and outside comers,field-fabricated pipe flashings,curb Tear strength,min.,Ibf/in(kN/m) ASTM 01004 10
corners,and scuppers. Heat aging:28 days%Retention ASTM 04434 90
Features and Benefits Resistance to Xenon-Arc weathering ASTMD4434 "No cracking/
-Xenon-Arc,5,040 kJ/m2 total crazing,
n KEE HP enhances flexibility,making it easier to field-fabricate details radiant negligihle
--Exposure,visual condition at 7X discoloration"
KEE HP increases weatherability for added protection at critical — —— —
transition areas and maximum longevity Typical properties and characteristics are based on samples tested and are not guaranteed
for all samples of this producL This data and information is intended as a guide and does not
» Superior weldability allows for consistent,high-quality seams in reflect the specification range for any particular property of this product.
penetrations and other critical roof areas
>t Available in white,gray,and tan to match Carlisle's Sure-Flex PVC and LEED*1 Information
KEE HP membranes
Pre-consumer Recycled Content 10%
Installation Post-consumer Recycled Content 0%
1. PVC Flashing is used to flash various roofing system details and Manufacturing Location Mountain Top,PA
penetrations.The specific installation method will vary based on Solar Reflectance Index 111(white),69(gray),81(tan)
the situation.
2- Use a lower temperature setting on the heat welder than when
welding non-reinforced PVC membrane.Typically,a setting of 7 on
a scale of 10 is appropriate for welding PVC Flashing. Received
3. Use the edge of the roller to crease the flashing into any membrane F�
step-offs for a proper seal. AUG 0 9 ?0 1 8
Review Gadisle specifications and details for complete installation %n I ?
information. Y��""//II
800-479-6832 1 P.O.Box 7000 i Carlisle, PA 17013 1 Fax:717-245-7053 i www.carlislesyntec.cam
06.23.17 rt9 2017 Carlisle. Carlisle and Sure-Flax are trademarks al Carlisle
nEPRINT CODE:600319-"Sure-Flex PVC Non-Relnforred Flashing Product Data Sheer" Lr_re is a regislered tmderramrk of the 0 S Green Building Council
EXPERIENCE THE CARLISLE DIFFERENCE /
sr,�t�-�r; .���s•r�,�r
Sure-Flex"' PVC
CFardd
Walkway
Rolls
brica ted
Accessory V
3_ Using an automated welder,weld all four sides of the PVC Walkway
Roll to the membrane.(Typically the same speed and temperature
settings will be used for this procedure as for welding membrane to
membrane.A test weld is always recommended prior to performing
welds to the installed membrane.)A hand-held welder may be
utilized;however,productivity will be decreased.
Review Carlisle specifications and details for complete installation
information.
Precautions
PVC Walkway Rolls are a maintenance item and are not covered under
the Carlisle membrane systems warranty.
» This product is to be used as a walkway only and is not designed as a
Overview perimeter warning line or a substitute for ballast.PVC Walkway Rolls
Carlisle's Sure-Flex PVC Heat Weldable Walkway Roll is designed to protect cannot be installed within 10' (3 m)of the roof perimeter.
the PVC membrane in those areas exposed to repetitive foot traffic and 0 If possible,allow the PVC Walkway Roll to relax prior to welding in place.
other hazards.
The PVC Walkway Rolls provide a defined path to walk on for those Packaging
servicing and repairing HVAC systems and other rooftop equipment found Each roll individually bagged.Fourteen rolls per skid.
on low-slope roofs. Size:36"wide x 60'long(91.4 cm x 18.3 m)
Walkways must be installed at all traffic concentration points(i,e. Weight:95 Ibs(roll)
roof hatches,access doors,rooftop ladders,etc.)regardless of traffic Color:Gray
frequency.Walkways must also be installed if regular maintenance(once a Thickness:80 mils
month or more)is necessary to service rooftop equipment.
Carlisle's PVC Walkway Rolls are part of the Certified Fabricated Accessory Typical Propertiesand Characteristics program.Certified Fabricated Accessories are the only factory- Typical
fabricated PVC accessories that meet the stringent quality tolerances Physical Property Test Method Properties Maximum
required to be included in a Carlisle warranted roofing system. _ Minimum
Dimensional Conformance ASTM D412 0.072(1.83) 0.088(2.24)
Features and Benefits Thickness,in.(trim)
» Increased slip resistance created with a diamond tread pattern Density,lbs./1113 wrlcm') ASTM D792 80.5(1.29) 84.3(i.35)
Enhanced PVC formulation Tensile Strength,psi(Mils) ASTM D63B 600(4.1)
:> Superior weathering package for long-term performance Tear Strength,Ibt/in(kNim) ASTM D624 100(17.5)
Typical properties and characteristics are based on samples tested and are not guaranteed
Installation for all samples of this product.This data and information is intended as a guide and doss not
reflect the specification range for any particular property of this product.
1. Use PVC Membrane Cleaner to prepare the membrane to be welded
to the walkway material. LEEW Information
2. Position the PVC Walkway Rolls, Cut the PVC Walkway Rolls into Pre-consumer Recycled Content 45%
maximum 10' lengths and position with a minimum 1"gap between
adjacent pieces to allow for water drainage.Cut the PVC Walkway Post-consumer Recycled Content 20%
Roll so a 4"minimum gap is created over any field splices.(As the Manufacturing Location Mountain Top,PA
aKachme.ntof the walkway to the membrane is permanent,this will Solar Reflectance index(SRI) N/A
allow ac'esstto the field seams.) --
800-479-6832 i P.0_Box 7000 I Carlisle, PA 17013 ± Fax: 717-245-7053 www.carlislesyntee.com
01,20.14�b 2014 Caritslo. Cadlsle and Surr.-Flat are trademarks of Carlisle
REPRINT CODE:605536-"Sure-FIeX PVC Walkway Rolls Product Data Sheol" LFED is a registered trademark of the U_5.Green RuMing Cmincd
CITY OF ARLINGTON
1
238 N. OLYMPIC AVE - ARLINGTON, WA. 98223
PHONE; (360) 403-3551
BUILDING PERMIT
Address:20200 71st Avenue NE Permit#:2121
Parcel#:00769800000300 Valuation: 168429.00
OWNER APPLICANT CONTRACTOR
Name:RHINO VENTURES Name:Sound Roof Services Name:Sound Roof Services,Inc.
Address:20100 71 ST AVE NE Address:18908 Hwy 99 Address: 19808 Hwy 99,Suite B
City,State Zip:ARLINGTON,WA 98223-7447 City,State Zip:Lynnwood,WA 98036 City,State Zip:Lynnwood,WA 98036
Phone: Phone:425-672-4730 Phone:425-672-4730
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Name: Name:
Address: Address:
City,State,Zip: City,State,Zip:
Phone: Phone:
LIC#: EXP: LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Commercial Re-Roof CODE YEAR: 2015
STORIES: CONST.TYPE:
DWELLING UNITS: OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;
NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S
COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110.
SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form
an coded City f Arlington#3101.eliLi i -I
Signalfre Print Name Date Released By D to
CONDITIONS
Call for Inspections.
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION
ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
9/5/2018 Processing/Technology Fee $25.00
9/5/2018 Re-Roof $1,996.95
Total Due: $2,021.95
Total Payment: $0.00
Balance Due: $2,021.95
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
l�
CITY OF ARLINGTON
' 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223
PHONE; (360)403-3551
BUILDING PERMIT
Address:20200 71st Avenue NE Permit#:2121
Parcel#:00769800000300 Valuation: 168429.00
OWNER APPLICANT CONTRACTOR
Name:RHINO VENTURES Name:Sound Roof Services Name:Sound Roof Services,Inc.
Address:20100 71 ST AVE NE Address:]8908 Hwy 99 Address: 19808 Hwy 99,Suite B
City,State Zip:ARLINGTON,WA 98223-7447 City,State Zip:Lynnwood,WA 98036 City,State Zip:Lynnwood,WA 98036
Phone: Phone:425-672-4730 Phone:425-672-4730
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Name: Name:
Address: Address:
City,State,Zip: City,State,Zip:
Phone: Phone:
LIC#: EXP: LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Commercial Re-Roof CODE YEAR: 2015
STORIES: CONST.TYPE:
DWELLING UNITS: OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,
NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S
COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110.
SALES"TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form
and coded City of Arlington#3101.
Signature Print Name Date Released By Dale
CONDITIONS
Call for Inspections.
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION
ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
9/5/2018 Processing/Technology Fee $25.00
9/5/2018 Re-Roof $1,996.95
Total Due: $2,021.95
Total Payment: $0.00
Balance Due: $2,021.95
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
Permit#: 2121
Permit Date: 08/27/18
Permit Type: COMMERCIAL RE-ROOF
Project Name: AMT
Applicant Name: Sound Roof Services
Applicant Address: 18908 Hwy 99
Applicant, City, State, Zip: Lynnwood, WA 98036
Contact: Brian Storey
Phone: 425-672-4730
Email: brian@soundroofservices.com
Scope of Work: Commercial re-roof with partial tear-off
Valuation: 168429.00
Square Feet: 0
Number of Stories: 0
Construction Type:
Occupancy Group:
ID Code:
Permit Issued: 09/06/2018
Permit Expires:
Form Permit Type:
Status: COMPLETE
Assigned To: Kristin Foster
Property
Parcel# Address Legal Description Owner Name Owner Phone Zoning
00769800000300 20200 71 STAVE NE RHINO VENTURES 637 Warehousing&
Storage Services
Contractors
Contractor Primary Contact Phone Address Contractor Type License License#
Sound Roof Services, 19808 Hwy 99, CONSTRUCTION Labor and SOUNDRS932J3
Inc Brian Storey 425-672-4730 Suite B CONTRACTOR Industries
Inspections
Date Inspection Type Description Scheduled Date Completed Date Inspector Status
R20.ACCESSORY No inspections called in for
11/12/2019 STRUCTURE this project was complete at Completed
FINAL site visit
Plan Reviews
Date Review Type Description Assigned To Review Status
08/27/2018 RESIDENTIAL RE-ROOF BUILDING
Fees
Fee Description Notes Amount
Processing/Technology $25.00
Re-Roof Residential Residential $1,996.95
Total $2,021.95
Attached Letters
Date Letter Description
09/05/2018 Building Permit
Payments
Date Paid By Description Payment Type Accepted By Amount
09/06/2018 Sound Roof Services check#10753 Launa Black $2,021.95
Outstanding Balance $0.00
Uploaded Files
Date File Name
09/06/2018 3906669-2121 Issued Permit.pdf
08/27/2018 3869341-2121 Application and Specs.pdf