Loading...
HomeMy WebLinkAbout20200 71st Ave Ne_BLD2121_2026 CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:20200 71st Avenue NE Permit#:2121 Parcel#:00769800000300 Valuation: 168429.00 OWNER APPLICANT CONTRACTOR Name:RHINO VENTURES Name:Sound Roof Services Name:Sound Roof Services,Inc. Address:20100 71 ST AVE NE Address:]8908 Hwy 99 Address: 19808 Hwy 99,Suite B City,State Zip:ARLINGTON,WA 98223-7447 City,State Zip:Lynnwood,WA 98036 City,State Zip:Lynnwood,WA 98036 Phone: Phone:425-672-4730 Phone:425-672-4730 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Re-Roof CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRCI10. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City )f Arlington#3101. -� Signalftre Print Name Date Released By DAG CONDITIONS Call for Inspections. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 9/5/2018 Processing/Technology Fee $25.00 9/5/2018 Re-Roof $1,996.95 Total Due: $2,021.95 Total Payment: $0.00 Balance Due: $2,021.95 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon _.. I • ,., I rrjGt'� 3�!6 Permit Information Date 8/27/2018 Permit Number 2121 Project Name AMT Applicant Name Sound Roof Services Applicant Address 18908 Hwy 99 City,State,Zip Lynnwood,WA 98036 Contact Brian Storey Phone 425-672-4730 Email brian@soundroofservices.com Permit Type Commercial Re-Roof Site Address 20200 71 st Avenue NE Valuation 168429.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 0 Proposed Use Commercial re-roof with partial tear-off Assigned To Kristin Foster Property Parcel Address Legal Owner Owner Phone Zoning 0076980QOOp300 120200 71ST AVE NE 1RHINOVENTURES 1637 Warehousing&Storage Services Contractors Contractor Name Primary Contact Phone Email Contractor Type License License# Sound Roof Services,Inc.03rian Store 425-672-4730 rian soundroofservices.com ONTRACTOR Labor and Industries'3OUNDRS932J3 Review Date Type Description Target Date Completed Date Assigned To Status 3/27/2018 Re-Roof 3/4/2018 Ouilding Pn Review Uploaded Files I Upload File Date File 77= Uploaded B 8/27/2018 1:42:24 PM JZ121 Application and Specs.pdf Foster.Kristin r -. 1 I i RE-ROOF PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360) 403-3551 Type of permit: 'ry(c(heck one) 1 ( ) Residential Commercial Valuation: 9 Project Address:181%_1 �00 30ALO71"UMAxflf)t0`HW0WAParcel ID#: Owner: 9 n%UA d V 42 M-y1 f e S L L.C ) ,/� Address: llpaeox eaq;l � City:,�i,16iM..Ll G� State: ,_fA Zip Code: Phone Number: ws_ , a q,J go) Email: yll�}10I'Lva vQtkttkfe 3 tLAe.}I A < Applicant:_ Roo 52v"V1GC� �, In,-- Address: �g�Q X W:4 .f��/tJ�P7�/tl City:1c 11 J�lllrjDLf/�� State: Wp Zip Code: Phone Number: yt 7�' %���L,� Email: br,1G14�1/C3�- />itP Contractor: Address: City: State: Zip Code: Phone Number: pp Email: Contractor's License Number: Sou D S—I.� .�2 Expiration: Type of Roofing Material:Cat-l1S1e 04 z>r1a��al��' Number of Existing Layers: LA Class Class of Roofing: A ® B ❑ C ❑ Replacing existing sheathing: Yes ❑ No cof tear off: ❑ Application over existing material: ����leu{'o�iThe fol owiis requi for NON-Residential Buildings: 'l �' • Existing roof structure and material: !6A N-4LfILOA0 ) VP,0141 sa tM L1W rP-0L4 _lF+q M&4 jT)ed • Two copies of the installation specifications and U.L.listed roof assembly. }+k • Occupancy of Building: Office Z oa4-1 v Retail Church Restaurant School trn a 0 M Pit e-ra `itq I hereby certify the above information is correct and that the construction o nd the occupancy and the use of the above described property will be accordance with the laws, rules and regulations of the State of Washington. The applicant will be responsible for providing a method of safely accessing roof for inspection. A final inspection and approval shall be obtained when the re-roofing is complete. &44(VL Applicants Signature Date Print Applicants _J N FOR STAFF USE ONLY Received AUG 0 9 2018 Permit# A pled By Amount Received Receipt# Date Received Q r N �J N -dr : LLJ -7t"%- • _, 4 ' _ -+ter:,,. � + w - �4. low Home : Espanol Contact "IMENN&E- La' b'o'r : Industries COSafety&Health Claims&Insurance c Workplace Rightso Trades&Licensing IM Washington State Department of Labor & industries SOUND ROOF SERVICES INC Owner or tradesperson 18908 HWY 99 STE B Principals LYNNWOOD,WA 98036 206-672-4730 STOREY,BRIAN D,PRESIDENT SNOHOMISH County ■ WILLIAMS,MICHAEL JAMES,VICE PRESIDENT Doing business as SOUND ROOF SERVICES INC WA UBI No. Business type 602 709 020 Corporation Governing persons BRIAN DOUGLAS STOREY MIKE JAMES WILLIAMS; License Verify the contractor's active registration/license I certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties ROOFING License no. SOUNDRS932J3 Effective—expiration 04/23/2007—05/01/2019 Bond DEVELOPERS SURETY 8,INDEM CO $12,000.00 Bond account no. 746471C Received by L&I Effective date 04/23/2007 04/17/2007 Expiration date Until Canceled Insurance Continental Insurance Co $1,000,000.00 Policy no. 5084577283 Received by L&I Effective date 04/06/2018 04/17/2014 Expiration date 04/17/2019 Insurance history Savings Help us , _ I . _� �� 'f _ i �'� i No savings accounts during the previous 6 y period. ; Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&1 Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 133,584-00 Doing business as SOUND ROOF SERVICES INC Estimated workers reported Quarter 2 of Year 2018"11 to 20 Workers" L&I account contact T2 I KATHY ULRICH(360)902-4829-Email:WITE235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. A"Washington« 1 EXPERIENCE THE CARLISLE DIFFERENCE srrvr�c srs�'�rn.•s Sure-71ex"' PVC Membrane Fully Adhered Roofing System The fully adhered system starts with a suitable surface upon which the Low-VOC PVC Bonding Adhesive or Hydragond-Water-Based PVC Bonding Adhesive is applied. Mechanically Fastened Roofing System The mechanically fastened system starts with approved insulation being fastened with a minimum of 5 fasteners per 4'x 8'board.The PVC membrane is then mechanically fastened to the deck using HP-X- Fasteners and Piranha Plates",or HP-XTRA Fasteners and Piranha XTRA Plates.Adjoining sheets of PVC membrane are overlapped over the fasteners and plates and joined together with a minimum IYz"-wide hot-air weld. Review Carlisle specifications and details for complete installation information. Overview Carlisle's Sure-Flex PVC is an advanced-formula,heat-weldable PVC Precautions thermoplastic membrane that is designed for long-term weatherability and » Sunglasses that filter out ultraviolet light are strongly recommended.as performance.The physical properties of the membrane are enhanced by a the membrane's white surface is highly reflective to sunlight.Roofing tenacious,weft-inserted polyester fabric that is encapsulated by thick PVC- technicians should dress appropriately and wear sunscreen. based top and bottom plies.The smooth surface of the PVC membrane , Smooth surfaces may cause slippery conditions due to frost and ice allows for a total-surface fusion and permanent weld,creating a consistent, buildup.Exercise caution during cold conditions to prevent falls. watertight,monolithic roof assembly.PVC can be used in adhered and I Care must be exercised when working close to a roof edge when mechanically fastened systems.The gray-colored bottom ply provides a surrounding area is snow-covered,as the roof edge may not be visual confirmation of a proper weld during the lap welding process. clearly visible. Features and Benefits Use proper stacking procedures to ensure sufficient stability of the » Wide choice of membrane sizes,thicknesses and colors materials. » Enhanced chemical resistance » Exercise caution when walking on wet membrane.Membranes may be » Energy efficiency slippery when wet. » Store PVC membrane in the original undisturbed plastic wrap in a Wide window of weltlability cool,shaded area and cover with light-colored,breathable,waterproof » Flexibility in low temperatures tarpaulins.PVC membrane that has been exposed to the weather or u Impact and puncture resistance contaminated with dirt must be prepared with PVC Membrane Cleaner » UV,ozone and oxidation resistance CITY OF ARLINGTON » Easy installation BUILDING DEPARTMENT » Available in white,gray,and tan APPROVED Installation DATE BY GO With minimal labor and few components required,PVC is quirk;md easy to -Received install.PVC systems are installed using an Automatic Heat Welder,making NO CHANGES AUTHORIZED sheet welding fast,clean and consistent. UNLESS APPROVED BY THE A I G ® 9 2018 BUILDING INSPECTOR 800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntee.com EXPERIENCE • ' sure-Flex PVC Membrane TypicalProperties • Characteristics Radiative for R• • ■ • Co • " Physical Property ASTM 04434 50-rill 60-rill 30-mil Requirement _ White Tan Gray Thickness over scrim,in.(nim) 0.016 min 0.022 0,027(0.686) 0.037 Physical Property Test Method PVC PVC PVC ASTM D4434 optical method (OAO) (0-559) (D,940) average of areas ENERGY STAR-E-903 Solar Spectrum 0.86 0,73 0.59 weight,Ibsnt°(kgtm') No requirement 0.33 (1.61) 0.40 (1.95) os5 Initial Solar Reflectometer (2,68) Reflectance Breaking strength Imn x co),Mile 275 min 320 x 300 330 x 300(So U8 x 3311 ENERGY STAR-E-903 Solar Spectrum 0.63 Pending Pending RN.m)AS1M 0751 grab method (48) (56 x 53) x 55) (63 x 58) Solar Reflectance after Reflectometer Elongation hank of relnhnce nenl(M) 25 ruin 30 x 30 30 x 30 30 x 30 3 years (Uncleaned) (CD),%ASTM(1751 grit)mntlm0 roaring strongih 1MD x r,Dl,Ibt IN) 90 nho too x 120 10o x 130 100 x 132 CRRC- ASTM C1549 0.86 0.73 0.59 ASTM 0751 pros.0,8[if.x 8 in. (4001 (445 x 5341 (445 x 57M (445 x 5871 Initial$niar Low temperature bend,ASTM PASS PASS PASS PASS Reflectance 02135,no cracks SA at-4010 (-40°C) (40"c) (-401C) Linear CRRC- ASTM C1549 0.63 0.60" 0.48' 012046houslat176*Fnal nge,%ASTM -_0.5max 0.4 0.4 0.4 Solar Reflectance 01204,6 hours at t76"F (uncleaned) Ozone resistance,no cricks 7x ASTM I PASS PASS PASS PASS after 3 years Dt149,100pphm,168 firs CRRC- AS I M C 1311 0.89 0.86 0.85 Water absorption resistance,mass% t3.0 max 2.0 20 2.0 Initial Thermal ASTM D570,166 hours at 150"F water Emittanre Field seam strength,VAR,(kN/m) No requirement 2S(d.4)min 25(4 4)min 25(4-4)min L'RRC- ASTM C7371 0.87 0.82' 0.81' ASTM 01876 tested in pool 60110.5) 60(10-5)ryp. 60(1G.51 ryp- typ Thermal Emdtance (uncleaned) Water vapor permeance,Perms, No requirement 0.10 nlax 0.10 max O.10 max after 3 years ASTM E96 proc.8 0,05 typ 005 typ 0,05typ Solar Reflective Index ASTM E1980 108 89 69 Puncture reslslanco-Federal,lot(kN) No requirement 280 320 380 (SRI) FTM 101C,method 2031 I Puncture resistance-Dynamic,J 20(14.7) PASS PASS PASS Solar Reflective Index ASTM E1980 75 70' 53, (It-lift)ASTM 05635 (SRI)SRI after 3 years Puncture resistance-Static,Hit(N) 33(146) PASS PASS PASS ASTM D5602 Rapid Ratings Xenon-Arc resistance,no PASS PASS PASS PASS crackslcrazing 10x,ASTM GIGS 0.35 W/m'at 340-0m,63°C 8.P.T. I s Information 12,600 kJlm1 total radiant exposure 10,00a hours Pre-consumer Recycled Content 10% Properties altar heat aging 90 min 90 min 90 min 90 min - ASTM 03045,56 days at 17611' 90 min 90 min 90 min 90 min Post-Consumer Recycled Content 0% greakltion roing(t1,%rained Manulacturin Location Greenville,IL Elongalibn raiM.,%retained g Typical properties and characleristics are based on samples tested and are not guaranteed for ailSolar Reflectance Index(SRI),Initial White:108.Tan:89,Gray:69 samples of this product-This data and Information Is intended as a guide and does not reflect the specification range for any particular property of this product. Supplemental Approvals, Statements and Characteristics ' n Sure-flex PVC meets or exceeds the requirements of ASTM D4434 Standard Specification for Poly(Vinyl Chloride)Sheet Roofing.Sure-Flex s PVC is classified as Type III and/or Type IV as defined by ASTM 04434. Sure-Flex reinforced PVC was tested for dynamic puncture resistance per ASTM D5635-04 using the most recently modified impact head- _ ....�..�..____,.. 3TA0 50-mil thick membrane was watertight after an impact energy of 22.5 J (16.6 ft-lbf),which passes the ASTM D4434 requirement. ri » Sure-Flex reinforced PVC was tested for static puncture resistance per ASTM D5602-98 and exceeded 33 Ibf(145 N),which passes the ASTM 04434 requirement. 800-479-6832 1 P.O.Box 7000 i Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntec.com 11.29.17(0 2017 Cadlsle Carlisle,HydroRend Sure-Flex,HP-X Fasteners and Piranha Plates am IrademaMs of Cadlc!e REPRINT CODE:605245 "Sure Flex PVC Membrane Producl Data Shea!" ENERGY STAR is a reglstered trademarx owned by the U 5 Government.'ENERGY STAR qualification is only valid in the U.G LEED is a registered Iradenark of the U 5 Green 0uddino Council EXPERIENCE THE CARLISLE DIFFERENCE SecurShield"' HD POLYIS® Insulation Product Characteristics pp-pppppPanel sizes: - 4'x 8'(1220 mm x 2440 mm) q 4'x4'(1220mmx1220mm) r.� Panel thickness:Y?(13 mm) �a Weight; 0.343 Ibs/sq.ft. 11 Ibs(4.99 kg)per 4'x 8'panel 5.5 Ibs(2.49 kg)per 4'x 4'panel �-s Installation Mechanically Attached Single-Ply Systems Each SecurShield HD panel must be secured to the substrate with approved Overview Carlisle fasteners and plates.Butt edges and stagger joints of adjacent panels.Install the roof membrane according to Carlisle specifications. Carlisle's SecurShield HD Pnlyiso Insulation is a rigid roof insulation panel composed of a high-density,closed-cell polyisocyanurate foam Fully Adhered Single-Ply Systems core laminated to a premium-performance,coated glass facer(CGF). Carlisle's SecurShield HD may be secured to the roof deck using Carlisle's Suitable for both re-roofing and new construction applications, FAST"and Flexible FAST adhesive,01yBond500rP'insulation adhesive, SecurShield HD is specifically designed fnr use as a cover board over a fasteners and plates,or hot asphalt(appropriate to the deck type)- variety of substrates.SecurShield HD delivers an R-value of 2.5, which For adhesive coverage or fastening patterns and requirements,please is significantly higher than roof cover boards made with other materials contact Carlisle's Design Services group. Butt the edges of the insulation such as wood fiber or gypsum. panels and stagger the joints.Install the membrane according to Carlisle Features and Benefits specifications, Review Carlisle specifications and details for complete installation N High-density insulating cover board information, » Exceptional protection against hail,rooftop traffic,mold,and moisture High-density formulation achieves FM severe hail rating(SH) bodes and Compliances »2 times higher R-value than wood fiber hoards ASTM C1289,Type II,Class 4,Grade 1 (109 psi max.) » » Compatible with all Carlisle single-ply roofing systems(Except Ballast) International Building Code(IBC)Section 2603 n Coated glass facer provides strong bond for adhered roofing applications UL Standard 790,263 and 1256:Component of Class A Roof Systems(refer to UL Roof Materials'system directory) FM Standards 4450/4470:Class 1 approval for steel roof-deck Productivity Boosting Features and Benefits: constructions(refer to FM RoofNav) Lightweight and easy to cut,handle,and » Caiifomia Codes of Regulations,Title 2.4,Insulation Quality Standard install-no crumbling of material License 9TI-1418 7 5 times higher R-value than gypsum cover _ n Third-party certification with PIMA Quality Mark for Lang-Term boards Thermal Resistance(LTTR)values p %s the weight of gypsum cover boards ' CAN/ULC S704,Type 3,Class 2 Received Florida Building Code Approval AUG 0 9 2018 800-479-6832 1 P.O.Sox 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 ; www.carlislesyntee.com EXPERIENCE ♦ CARLISLE DIFFERENCE - .SY{V7-EG ,4YSTEM SecurShield HD POLYISO Insulation Precautions Insulation must be protected from open flame and kept dry at all times.Install Typical only as much insulation as can he covered the same clay by completed roof- Physical Property Test Method Value covering material.Carlisle will not he responsible for specific building and compressive strength ASTM 01621 109 psi max roof design,for deficiencies in construction or workmanship.for dangerous Dimensional Stability ASTM 02126 <0.5%linear change conditions on the lobsite,or for improper storage and handling.Technical (7 days) specifications shown in this literature are intended to be used as general water Absorption_ ASTM C209 <1 IN,volume guidelines only and are subject to change without notice.Call Carlisle for R-value ASTM C518 2.5 more specific details or refer to PIMA Technical Bulletin No. 109:Storage and Thickness Handling Recommendations for Polyiso Roof Insulation. Service Temperature 260°F(126°C)or less Resistance to Maid ASTM D3273 Passed Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. LEEDI Information Pre-consumer Recycled Content 0% Post-consumer Recycled Content : 9% Manufacturing Locations Smithfield,PA Franklin Park,IL Tooele,UT Montgomery,NY Lake City,FL Terrell,TX, Puyallup,WA Solar Reflectance Index(SRI) N/A �� w 04 11.1A 0201G Canisle. 800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislasynlec.com REPRINT LODE:GG5D75-`SacarShleld Ili)Polyisa Pmducl Dala Sheer" Canisle,SeGUIShreiA.Helrlele FAST and FAST are trademarks of Cadisle Oly9ond500 Is a registered trademark al 0MG.LEED IS a registered trademark of the U.S-Green Building Council EXPERIENCE / CARLISLE DIFFERENCE ' H PA Fastener Precautions n The strength of different roof decks varies widely and ran be adversely affected by moisture and other conditions.Therefore,Carlisle AAA recommends conducting a fastener pull test to help evaluate deck conditions and fastener suitability. MCare must be taken not to overdrive the fastener. Eye protection is recommended during drilling and installation. �'Packaging Information Size Weight/Carton Thread Length Packaging Inches(mm) (Kg) Inches(mm) Fasteners/Carton 2(50) 20 Ibs(9.08) Full 1,000 3(75) 291bs(13,16) Full 1,000 Overview 4(100) 381bs(17.25) 3(76) 1,000 Carlisle's HP-X Fastener is a specialized,high performance fastener 5(125) 24lbs(10.89) 4(102) 500 designed to secure Carlisle single-ply membrane and insulation.The 6(150) 28lbs(12.71) 4(102) 500 HP-X Fastener can be used on steel decks(20-gauge[0,91 mm]or 7(175) 34lbs(15.44) 4(102) 500 22-gauge[0.76 mmj or wood[minimum 15/az"[12 mml CDX plywood]). The HP-X Fastener is designed to offer an optimum combination of 8(200) 38Ibs(17.25) 4(102) 500 driving performance,back-out,and corrosion resistance with excellent 9(230) 42 ibs(19.07) 4(102) 500 pull-out performance. 10(255) 47lbs(21.33) 4(102) 500 11 (280) 52 Ibs(23.61) 4(102) 500 Features and Benefits 12(305) 561bs(25.42) 4(102) 500 A Oversized heavy shank and#15 thread diameter for enhanced 14(355) 32 Ibs(14.52) 4(102) ?.50 pull-out resistance 16(405) 38 Ibs(1725) 4(102) 250 Miniature drill point penetrates decks quickly and contributes to exceptional resistance to back-out as well as pull-out Deep buttress threads further increase pull-out and back-out Typical Properties resistance Head 43 Phillips Truss Head » Excellent corrosion resistance,surpassing the FM4470 corrosion test .435"(11.04 mm)diameter Thread 265"(6.73 mm)diameter Installation Shank .202"(5,13 mm)diameter 1. No pre-drilling is necessary for wood and steel decks.Simply insert coaling CH-110 the HP-X Fastener through an approved Carlisle plate and install Typical properties and characteristics are based on samples tested and are not guaranteed with a standard clutch drive electric screw gun(0-2,500 rpm). for all samples of this product.This data and information is intended as a guide and does not 2. Optimum fastener performance is achieved when the fastener is reflect the specification range for any particular properly of[his product. installed perpendicular to the deck and into the top flutes of a steel deck. Review Carlisle specifications and details for complete installation Received information. AUG 0 9 M8 ��721Z1 800-479-6832 1 P.0 Box 1000 1 Carlisle, PA 17013 1 Fax:717-245-7053 1 www.carlislesyntee.com 0114,16 t 2O16 Carhsle Carlisle,Sure-Weld and Sure-Flex are lradenrarks of Carlisle WES ONLY:CSi-7O66"HPA Fastener Product Onta Sheet' EXPERIENCE THE CARLISLE DIFFERENCE SYNTSC SYSTEMS Sure-Flex"' PVC Low-VOC Bonding Adhesive Application I. The surface on or against which adhesive is to be applied shall be clean,smooth,dry,free of fins,sharp edges,loose and foreign materials,oil and grease,Depressions greater than�/4"(6 mm) should be feathered using epoxy,mortar or other approved patching material.All sharp projections shall be removed by sweeping, blowing or vacuum cleaning. 2. After thorough stirring(minimum 5 minutes),apply PVC tow-VOC Bonding Adhesive to substrate and membrane using a 9"(229 mm) 1 medium nap roller.Application shall be continuous and uniform, ° r avoiding globs or puddles.An open time of 5 to 50 minutes(based on drying conditions)is recommended before assembly.PVC Low- VOC Bonding Adhesive must be allowed to dry until it does not string or stick to a dry finger touch.The membrane and substrate will be dry(non-tacky)to the finger touch.Any coated area that has been Overview exposed to rain should be allowed to dry and then recoated.Do not Sure-Flex PVC Low-VOC Bonding Adhesive is a high-strength solvent- apply adhesive to splice areas to be hot-air welded. based contact adhesive that allows bonding of PVC and KEE membranes 3. Roll the membrane onto the adhesive-coated substrate while to various porous and non-porous substrates.It is specially formulated avoiding wrinkles.Immediately brush down the bonded portion using a blend of VOC-exempt and non-exempt solvents to be in compliance of the sheet with a soft-bristle push broom or a clean dry roller with the state of California Clean Air Act of 1988(updated in 1997)and applicator to achieve maximum contact. as further regulated by California's Air Quality Control Districts listing Review Carlisle specifications VOC limitations.This product also meets the<250 gpl VOC content fications and details for complete application requirements of the OTC Model Rule for Single-Ply Roofing Adhesives. information. Features and Benefits precautions • High-strength adhesive that allows quick bonding Review the applicable Material Safety Data Sheet for complete safety information prior to use. • Can be easily applied with a medium nap roller PVC Low-VOC Bonding Adhesive is EXTREMELY FLAMMABLE.It • Provides excellent adhesion between various substrates and PVC contains solvents that are dangerous fire and explosion hazards when and/or KEE membranes exposed to heat,flame or sparks.Do not smoke while applying.Do not use in a confined or unventilated area.Vapors are heavier than air and Coverage Rate use travel along ground or may be moved by ventilation and ignited by 60 112(5.6 m2)per gallon finished surface.Coverage rates are average and pilot lights,other flames,sparks,heaters,smoking,electrical motors, may vary due to conditions on the jobsite.Porous surfaces and substrates static discharge,or other ignition sources at locations distant from may require more bonding adhesive than the typical coverage rate. material handling point.All containers should be grounded when material is transferred from one container to another.A red caution label is Mixing required when shipping.A fire extinguisher should be available.In case Stir thoroughly until the adhesive is uniform in color.Minimum 5 of fire,use water spray,foam,dry chemical or carbon dioxide.Do not minutes stirring is recommended. use a solid stream of water because it can scatter and spread the fire, r Avoid breathing vapors.Keep container closed when not in use. Use with adequate ventilation.If inhaled,remove to fresh air. If not breathing,perform artificial respiration.If breathing is difficult,give oxygen.Call a physician immediately.During application,efforts must 800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislasyntec.com EXPERIENCE ME CARLISLE DIFFERENCE AYX=j Ig SYNTEC, SYS 7 Ears Sure I ex PVC Low-VOC Bonding Adhesive be made to prevent fumes from entering the building via air ventilation Typical Properties and Characteristics ducts.Do not place open containers or mix adhesive near fresh air intake units.When possible,shut down or seal off the closest units. Base Synthetic rubber If swallowed,DO NOT INDUCE VOMITING.Call a physician immediately. Color Pale yellow to orange to amber n Avoid contact with eyes.Safety glasses or goggles are recommended. Solids 23.6-29.6% If splashed in eyes,immediately flush eyes with plenty of clean water Flash Point -4°F(-20°C)SETA for at least 15 minutes.Contact a physician immediately. Brookfield Viscosity 1500-4500 centipoises n Avoid contact with skin.Wash hands thoroughly after handling.In case Average Net Weight 6.9-7.7 Ibs/gal(0.8—0.9 kgA) of contact with skin,thoroughly wash affected area with soap and packaging 5-gal pail water_Contact physician if irritation persists. Shelf Life 1 year Note:Permeation-resistant gloves(that meet ANSI/ISEA 105-2005) Typical properties and characteristics are based an samples tested and are riot guaranteed are recommended to be warn when using this product to protect hands for all samples of this product.This data and intormatlan is intended as a guide and does not from irritating ingredients. reflect the specification range for any particular property of this product. Do not thin PVC Low-VOC Bonding Adhesive-Thinning will affect performance.Excessively thick or gelled material should be discarded. LEEDI Information U Jobsite storage in excess of 90'F(32°C)may affect product shelf life. Pre-consumer Recycled Content 0% Should the PVC Low-VOC Bonding Adhesive be stored at temperatures Past-consumer Recycled Content 0% lower than 60'F(15'C),restore to roam temperature priorto use. VOC Content <250 g/I n Opened containers of PVC Low-VOC Bonding Adhesive should be used Manufacturing Location Carlisle,PA within 48 hours,Adhesives will begin to thicken after this point,making it difficult and eventually impossible to control applied thickness.In hot weather,do not leave sealed containers on roof for prolonged periods of time.In cold weather,keep material at room temperature until ready to use_Stir adhesive occasionally while using. Adhesive must be allowed to dry thoroughly.If membrane is mated with the substrate prior to the adhesive being dry,blistering will occur and will not subside over time. KEEP OUT OF REACH OF CHILDREN, Received AUG 0 9 2018 Wr7 7,124 800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.Garlislesyntec.com 09-21.13®2013 Carlisle, Carlisle and Sure-Flex are trademarks of Carlisla nEPDINTC,ODE:605666-"Sure-Flex PVC Low-VOC Bonding Adhesive Product Data Sheet' LEED is a registered trademark of fire U.S.Green Building Council EXPERIENCE THE CARLISLE DIFFERENCE .� SYNTEc -YSTkFNFF, Sure—Flex"' PVC Cortilied Fabricated y Coated Metal Accessory Installation 1 Install Sure-Flex PVC Coated Metal with a%"to;,4" (3-6 mm)gap between adjoining sections. 2. Install 2"(5 cm)-wide foil tape over joints. 3. Heat-weld a 6"(15.5 cm)-wide piece of Sure-Flex PVC Flashing over each joint. 4. Position Sure-Flex PVC membrane and heat-weld to the Sure-Flex PVC Coated Metal with a minimum 1t/2" (4 cm)weld. Review Carlisle specifications and details for complete installation information. Precautions » Store Sure-Flex PVC Coated Metal in a cool,shaded area,and cover with light-colored,breathable,waterproof tarpaulins.Sure-Flex PVC Coated Metal that has been exposed to the weather must be prepared Overviews with Carlisle's PVC Membrane Cleaner prior to hot-air welding. Carlisle's Sure-Flex PVC Coated Metal is a galvanized steel sheet with a » Do not install Sure-Flex PVC Coated Metal in such a way that the laminate of non-reinforced Sure-Flex PVC flashing.The sheet is cut into membrane side is in direct contact with asphalt,coal tar pitch, the appropriate width and used to fabricate metal drip edges or other polystyrene,or other petroleum-based products. roof perimeter edge profiles.Sure-Flex PVC membrane may be welded directly to the coated metal,eliminating the need to strip in the metal with Characteristics a separate piece of membrane.The metal is available in 4-foot by 10-footProperties ' (1.2 m by 3.1 m)sheets and comes packaged 10 sheets per pallet. Sheet Sae 4 foot by 10 foot(1.2 in by 3.0 m) Carlisle's Sure-Flex PVC Coated Metal is part of the Certified Fabricated weight 1.1 Ib/Itz(5.4 kg/mz) Accessory(CFA)program.Certified Fabricated Accessories are the Color White,Gray and Tan only factory-fabricated PVC accessories that meet the stringent quality Flashing Thickness 0.035 inches(0.9 mm)nominal tolerances required to be included in a Carlisle warranted roofing system. Steel Thickness 0-024 inches(0.6 mm)nominal(24 gauge) PVC coated aluminum and stainless steel are available in 4'x 10'sheets on — a special order basis in white,gray,and tan.Contact customer service for Steel Type Ilot Dipped Galvanized Steel—GOO minimum orders and lead times. Packaging 10 sheets per pallet Typical properties and characteristics are based on samples tested and are not guaranteed Features and Benefits for all samples of this product.This data and information is intended as a guide and does not reflect the specificabon range for any particular property of this product. » Allows direct welding of Sure-Flex PVC membrane to the coated metal, eliminating the need to strip in edging with additional membrane Easy to cut and form to Create a variety of edge sizes and profiles EED11 Information » Practical and cost-effective way of flashing roof edges Pre consumer Recycled Content j 0% ,,Available in white gray,and tan colors Post-consumer Recycled Content mya n Manufacturing Location Scranton,PA » Matches membrane color to create a uniform look Solar Reflectance Index White:ll I Gray:43 Tan:50 600-479-6a32 I P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntee.com 09.0R.1e 6 2016 CarOsle. REPRINT CODE 605539-'Sure-Flex PVC Coaled Metal Product Data Sheol" Carlisle and Sure-Flex are trademarks at Carlisle EXPERIENCE THE CARLISLE DIFFERENCE Sure-Flex"' PVC �jertified Molded Pipe Flashing Accessory Installation 1. Cut Pipe Seal between double-ribbed cutting guides,one size smaller than the pipe diameter. Do not cut off raised ring. 2. Pull Pipe Seal over pipe until base flange is in contact with the membrane.It may be necessary to apply heat to the top portion of the Pipe Seal to allow installation over the pipe. 3. Mark pipe around the top of the Pipe Seal. 4. Pull Pipe Seal upwards on pipe until mark on the pipe is visible. 5. Apply Universal Single-Ply Sealant below the mark that indicates the top of the installed Pipe Seal. 6. Pull Pipe Seal back down over pipe and into position. Overview 7. Heat-weld the Pipe Seal base flange to deck membrane. 8. Install a stainless steel universal clamping ring to provide constant Carlisle's Sure-Flex PVC Pipe Seals are injection-molded,pre-formed compression of the sealant. flashings for pipes.75"(19 mm)to 8"(203 mm)in diameter.This labor- saving accessory provides a quick and reliable way to waterproof round Review Carlisle specifications and details for corrrplete installation pipe penetrations. information. Sure-Flex PVC Pipe Seals are part of Carlisle's Certified Fabricated Precautions Accessory(CFA)program.Certified Fabricated Accessories are the only factory-fabricated PVC accessories that meet the stringent quality Remove all lead and other flashing. tolerances required to be included in a Carlisle warranted roofing system. A Temperature of pipe must not exceed 140*F(60°C). Install a minimum of four fastening plates around pipe penetrations. Features and Benefits Position fastening plates around the penetration so they are covered by Provides a reliable method of waterproofing round pipe penetrations the Pipe Seal flange.A minimum 1.5"-wide weld must be maintained Provides substantial labor savings compared to field-fabricating from around the outer edge of the flange beyond the plates.If fastening non-reinforced flashing plates cannot be installed in a manner to allow a minimum 1.5"weld, the plates must be placed outside the Pipe Seal flange and covered Provides a more consistent appearance than field-fabricated pipe with a reinforced Sure-Flex membrane overlay. flashings Store Pipe Seals in a cool,shaded area and cover with light-colored, Double-ribbed cutting guide facilitates easier,smoother,and breathable,waterproof tarpaulins.Sure-Flex Pipe Seals or membranes straighter cuts that have been exposed to the weather must be prepared with PVC :y Rib design holds the clamp in the proper position Membrane Cleaner prior to hot-air welding. Typical . •- Productivity Boosting Features and Benefits: Sizes 3l4"to 8"O.D.Pipe(19 to 203 mm) � Up to 60°le labor savings compared to Packaging 8 per box __.____. traditional field fabrication ` r Weight(each) 0.55 Ibs(0,25 kg) xi Quick and simple installation with no _ Material PVC compound Received stretching required Color White,Tan,and Gray A l fir' q pp b Provides a consistent,finished appearance ' ' i ` Typical properties and characteristics are bused on samples tested and are not q nranCe P '" 2 O 1 " for all samples of this product.This data and informahon is intended as a guide and does not reflect the specification range for any particular property of this product, LA 800-479.6832 1 RO.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carl isle syntec.cam DIFFERENCEEXPERIENCE THE CARLISLE ta x=:f 4gr sYjv-mac SYOT P40 Sure-Flex PVC Molded Pipe dashing Please use the chart below to cross-reference your pipe size with the proper step to cut as shown. Copper • • Nominal Tube Sae A" 1" 1 1A, 1 1k" 2" 2,hN 3' 401 5• 6" all 88 1 13 138 1.63 2,13 2.63 3.13 4.13 5.13 6.13 NIA Step of Boat Used I 1 1 1 h 2 2 3 4 5 6 N/A ScheduleI .1 Steel PipePVC Standard Polyethylene Pipe IPS Nominal Tube Sae 2A" 1" 1 1/4" 1 112" 2" 2112" 3" 4" 5" 6" all Pipe O.D. 1.06 1.32 1.66 1.90 2.38 2.88 3.50 4.50 5.56 6.63 8.63 Step of Boat Used 1 1 1 'h 1'k 2 3 3 4 5 6 B Pipe Pit Class A&Spun 100-250 Pit Class B,C&0 Nominal Tube Sae 2" 3" 4" 614 8" 2" 3" 4" o"" 8" Pipe Q.D. 2.50 3.96 4.80 6.90 9.50 N/A 3.96 5.00 71n 9.30 Step of Boot Used 2 4 5 6 NIA N/A 4 5 6 NIA Sewer - Soil Pipe PVC Plastic SDR 35&41...Cast Iron Soil Pipe no hub..,service weight&extra heavy Nominal Tube Sae 4" 4" 4„ 4" 6" 6" 6" 6" 8" 8„ 8" 8„ Pipe H. ' 4.22 4.38 4.30 4.62 6.28 6.30 6.30 6.62 8.40 8,38 8.38 8.75 Step of Boot Used _ 4 4 4 4 6 6 6 6 8 8 8 8 Conduit EMT Nominal Tube Sire }- 34 1" 1 1/4" 1'/a" 2" 2 h" 3" 3 h„ 4" Pipe O.D. -922 1.16 1.51 1.74 2.19 2.88 3.50 4.00 4.50 Step of Boot Used 1 1 I 116 2 3 3 4 4 Conduit Nominal Tube Size 35" 1" 1114.. 1 1/2 2" 2 /2" 3" 3,,4" 4" Pipe O.D. 1.02 1.29 1.63 1,88 2.36 2.85 3.47 3.97 4.46 Step of Boot Used 1 1 1 h 1 %i 2 3 3 4 4 Conduit Rigid Nominal Tube Sae + A" 1" 1'M" 1 W" 2" 21h" 3" 3 1h" 4" 5" Pipe O.D. 1 1.05 1.32 1.66 1.90 2.37 2.87 3.5- 4 4.5 5.56 Step of Boot Used 1 1 1 '1h 1 i6 2 3 3 4 4 5 800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntec.com 01.10,16®2016 Catlisle REPRINT CODE:605152-'Sure-Flex Pipe Seals PrDduC!Oala Sheet" Carlisle and Sure-Flex are Irdderuarks of Carlisle EXPERIENCE THE CARLISLE DIFFERENCE SYNTEC 8Y'BT�M,S gi 4 Azi Id Sure-Flex... PVC Cortrlied Inside Corners l A�G s�o ' Installation 1. Position the PVC Inside Corner into the comer,begin welding at the i innermost corner point and work away from the corner. 2. Use the edge of the roller to crease the corner flashing into any 1 membrane step-off to create a proper seal. 1 3. Probe all welded edges of the corner once the material has been completely cooled to ensure watertight performance. Review Carlisle specifications and details for complete installation information. Precautions Store PVC Inside Corners in a cool,shaded area and cover with light- F colored,breathable,waterproof tarpaulins.PVC Inside Comers or PVC membranes that have been exposed to the weather or contaminated Overview with dirt must be prepared with PVC Membrane Cleaner prior to hot-air Sure-Rex PVC Inside Corners are pre-molded and are used for flashing welding. the inside comers on a variety of details. Installation is fast and easy with no cutting or stretching required.This product is available in white,gray and tan. _ Carlisle's PVC Inside Comers are part of the Certified Fabricated Accessory Thickness D6o"(1.52 mm) (CFA)program.Certified Fabricated Accessories are the only factory- fabricated PVC accessories that meet the stringent quality tolerances Packaging 12/bag required to be included in a Carlisle warranted roofing system. Material Injection-molded non-reinforced PVC flashing Color White,Gray and Tan Features and Benefits Forms easily into out-of-square corners that are not exactly 90 degrees LEEDI Information p Provides substantial labor savings compared to field-fabricating Pre-consumer nemicted Content D46 the flashing detail from non-reinforced flashing Post-consumer Recycled Content 11'I >3 More consistent appearance than inside corners field-fabricated Manufacturing Location Bloomingdale,IL from flashing Solar Reflectance Index(SRI) White:111 Gray:43 Tan:50 Received AUG 09 ?018 12? ', 800-479-6832 1 P.D.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntee.cam 1122 13 0 2013 Carlisle Carlisle and Sure Flex are trademarks of Carlisle REPRINT CODE:605146-'Sure-Flex PVC Inside Corners Product Data Sheet" LEED Is a registered trademark of the U S.Green Building Council EXPERIENCE THE CARLISLE DIFFERENCE / • —SYNITEO sY.s=A4-- S u re-F!ex"' PVC Cje,nned T Fbbrccated i-Joint Covers Accessory Installation 1. If membrane has been exposed to the weather,clean splice intersection area with PVC Membrane Cleaner. 2, Use a lower temperature setting on the heat welder than that used for welding reinforced membrane.(Typically a setting of 6-7 on a I I scale of 10 is appropriate for welding PVC T-Joint Covers.) 3. Center the PVC T-Joint Cover over the splice intersection,begin welding at the center point and work towards the outside.Use the edge of the roller to crease the PVC T-Joint Cover into membrane step-offs to achieve a proper seal. 4. Once the weld area is completely cool,check all splices for voids and cold-welds with a seam probe.Make any needed repairs. Review Carlisle specifications and details for complete installation information. Overview Sure-Flex PVC T-Joint Covers are used to seal step-offs at splice Precautions intersections.Installation is mandatory on all 60-and 80-mil PVC systems The PVC T-Joint Cover is not intended for use to overlay fasteners and and air 50-mil systems where step-offs have not been property sealed.PVC plates as this requires the use of reinforced membrane. T-Joint Covers are formed from 60-mil white and 40-mil gray and tan non reinforced PVC cut into a perfect 4.5"-diameter circle.Packaged in a box Store the PVC T-Joint Covers in a cool,shaded area and cover with containing 100 covers.Available in white,gray and tan. light-colored,breathable,waterproof tarpaulins.PVC T-Joint Covers that have been exposed to the weather prior to use must be prepared Carlisle's PVC T-Joint Covers are part of the Certified Fabricated Accessory with PVC Membrane Cleaner before hot-air welding. (CFA)program.Certified Fabricated Accessories are the only factory- fabricated PVC accessories that meet the stringent quality tolerances Typical Properties required to be included in a Carlisle warranted roofing system. Saes 4.5"(114 mm) Features and Benefits Thickness 0.060"(1.52 mm)White 0.040"(1.02 mm)Tan and Gray u More consistent appearance than hand-cut flashing - Packaging 1001box u Provides substantial labor savings compared to field-cut T-Joint covers Weight(per box) 3.5lbs(1.6 kg) > Provides a more professional appearance than field-fabricated covers Material Non-Reinforcer]PVC Seals channels at splice intersections created by seam step-offs Color White,Gray and Tan Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product This data and information is intended as a guide and does not rellect the specification range for any particular property of this product. LEEDI Information Pre-consumer Recycled Content 0°/a Post-consumer Recycled Content 0% Manufacturing Location Eugene,OR Bloomingdale,IL Solar Reflectance Index(SRI) White:111 Gray:43 Tan:50 800-479.6832 1 PA.Box 7000 l Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntee.com 11.22,13 0 2013 Carllsle Carlisle and Sure-Flex are trademarks of Carlisle REPRINT C00F 005150-'Sure-Flex PVC T-Joint Covers Producl Data Sheer" LEFT)is a regislered trademark of the U.S Green Building council EXPERIENCE e ! RLISLE DIFFERENCE !• SYSTiEMS Sure-Flex"' PVC Non-Reinforced Flashing Precautions h Review the applicable Safety Data Sheet for complete safety information prior to use. Sunglasses that filter out ultraviolet light are strongly recommended,as white surfaces are highly reflective.Roofing technicians should dress appropriately and wear sunscreen. Store PVC Flashing in a cool,shaded area and cover with light-colored, breathable,waterproof tarpaulins.PVC Flashing that has been exposed to the weather for approximately 7 days or longer must be prepared with PVC Membrane Cleaner prior to hot-air welding. PropertiesTypical Properties ASTM Test Method Specification Overview Tolerance on nominal Thickness ASTM D751 .8 Carlisle's Sure-Flex PVC Non-Reinforced Flashing is a 60-mil thermoplastic Weight,Ib/1`12(kglm2),typical 0.44 Ib/ft2 polyvinyl chloride(PVC)membrane enhanced with KEE HP plasticizer for Breaking strength,min,Ibflin.(N) ASTM D751 Proc.B 167.60(MD), increased longevity and enhanced performance.Available in white,gray, 142-88(CD) and tan,PVC Flashing is offered in 12"and 24"by 50'rolls.When the use Elongation at Break,min.,% ASTM D751 Proc.B 399.60(MD), of prefabricated accessories is not feasible,PVC Flashing can be used to 420.27(CD) create inside and outside comers,field-fabricated pipe flashings,curb Tear strength,min.,Ibf/in(kN/m) ASTM D1004 10 corners,and scuppers. Heat aging:28 days 9'.Retention ASTM 04434 90 Features and Benefits Resistance to Xenon-Arc weathering ASTM D4434 "No cracking/ -Xenon-Arc„5,040 kJ/m2 total crazing, KEE HP enhances flexibility,making it easier to field-fabricate details radiant negligible -Exposure,visual condition at 7X discoloration" :> KEE HP increases weatherability for added protection at critical transition areas and maximum longevity Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product.This data and information is intended as a guide and does not » Superior weldability allows for consistent,high-quality seams in reflect the specification range for any particular property of this product. penetrations and other critical roof areas » Available in white,gray,and tan to match Carlisle's Sure-Flex PVC and LEEDO Information KEE HP membranes Pre-consumer Recycled Content 10% Installation Post-consumer Recycled Content 0% 1. PVC Flashing is used to flash various roofing system details and Manufacturing Location Mountain Top,PA penetrations.The specific installation method will vary based on Solar Reflectance Index 111(white),69(gray),81(tan) the situation. 2. Use a lower temperature setting on the heat welder than when welding non-reinforced PVC membrane.Typically,a setting of 7 on a scale of 10 is appropriate for welding PVC Flashing. Received 3. Use the edge of the roller to crease the flashing into any membrane AUG � step-offs for a proper seal. ll 0 9 ?0 1 8 Review Carlisle specifications and details for complete installation �jY�"/I �JV�l' l information. 800-479-6832 1 R0.Box 7000 i Carlislo,PA 17013 1 Fax:717-245-7053 I www.carlislosyntec.com 05 23 17 0 2017 Carlisle, Carllsle and SUM-FIeK are trademarks of Carllsie REPRINT COM:600319-'Sure-Flex PVC Non-neinforred Flashing Product Data Sheet" LEFn is a registered trademark LA the U S Green Building Council EXPERIENCE THE CARLISLE DIFFERENCE ta Sure#-Flek' PVC �ertirle� Fabric3t.d Walkway Rolls Accessory 3. Using an automated welder,weld all four sides of the PVC Walkway Roll to the membrane.(Typically the same speed and temperature settings will be used for this procedure as for welding membrane to membrane.A test weld is always recommended prior to performing welds to the installed membrane.)A hand-held welder may be utilized;however,productivity will be decreased. Review Carlisle specifications and details for complete installation information. Precautions num I -L VParnvrar nU115 are a Illdll llCllFAIIGe Ilelll a11U ale Ildl GUVered under the Carlisle membrane systems warranty. This product is to be used as a walkway only and is not designed as a Overview perimeter warning line or a substitute for ballast.PVC Walkway Rolls Carlisle's Sure-Flex PVC Heat Weldable Walkway Roll is designed to protect cannot be installed within 10'(3 m)of the roof perimeter. the PVC membrane in those areas exposed to repetitive foot traffic and If possible,allow the PVC Walkway Roll to relax prior to welding in place. other hazards. The PVC Walkway Rolls provide a defined path to walk on for those Packaging servicing and repairing HVAC systems and other rooftop equipment found Each roll individually bagged.Fourteen rolls per skid, on low-slope roofs. Size:36"wide x 60'long(91.4 rm x 18.3 m) Walkways must be installed at all traffic concentration points(i.e. Weight:95 Ibs(roll) roof hatches,access doors,rooftop ladders,etc.)regardless of traffic Color:Gray frequency.Walkways must also be installed if regular maintenance(once a Thickness:80 mils month or more)is necessary to service rooftop equipment. Carlisle's PVC Walkway Rolls are part of the Certified Fabricated Accessory Typical Properties • Chairacteristics (CFA)program.Certified Fabricated Accessories are the only factory- Typical fabricated PVC accessories that meet the stringent quality tolerances Physical Property Test Method Properties Maximum required to be included in a Carlisle warranted roofing system. Minimum Dimensional Conformance ASTM D412 0.072(1.83) 0,088(2.24) Features and Benetits Thickness,in.(mm) Increased slip resistance created with a diamond tread pattern Density,lbs./ft3(gr/cm3) ASTM 0792 80.5(1-29) 84.3(1.35) Enhanced PVC formulation Tensile Strength,psi(MPa) ASTM D638 600(4.1) Tear Strength,Ibflin(kN/m) ASTM D624 100(17.5) Superior weathering package for long-term performance - - Typical properties and characteristics are based on samples tested and are not guaranteed Installation for all samples of this product.This data and information is intended as a guide and does not reflect the specification range for any particular property of this product- 1- Use PVC Membrane Cleaner to prepare the membrane to be welded to the walkway material. Information 2. Position the PVC Walkway Rolls. Cut the PVC Walkway Roils into Pre consumer Recycled Content 45% maximum 10' lengths and position with a minimum 1"gap between — adjacent pieces to allow for water drainage.Cut the PVC Walkway Post consumer Recycled Content 20% Roll so a 4"minimum gap is created over any field splices.(As the Manufacturing Location Mountain Top,PA attachment of the walkway to the membrane is permanent,this will Solar Reflectance Index(SRI) N/A _allow accesstto the field seams.) 800-479-6832 i P.0-Box 7000 1 Carlisle, PA 17013 I Fax:717-245-7053 ; www.carlislosyntec.com 01.20.14 s-2014 cadlsle varllsle and Sure-Flex are trademarks of Carlisle REPAINT CODE:605536-'Sure-Flex PVC Walkway Rolls Product Data Sheet" LEER is a registered trademark of the If S-Green Building Council R E-ROOF PERMIT APPLICATION °" Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403--3551 Type of permit: (check one) 't ( ) Residential Commercial Valuation: 8 /M` ® Project Address: )� � ' I� �C� 'xy��7�r 1't N�ftf1,�`)�,(�!}�Parcel ID#: Owner: 'A G L�� \ri.1�c?S , L 1.L ,, � Address: P P a eox call a city:5.1.�Gtvinti►S tl t S '' State:� Zip Code:q��4 Phone Number: `1 _h-�c�o�(�' LCL� Email:-M ��G>> 7 yet�fitnC�5 , b�le_t Applicant: �,\� �c?OT SC�V Uc1�C� S t l oz Address: i ggC?1� W,1 qq�} SG JIJfe—f7 City: '! 't " '' 64 State: `laJ`r Zip Code: e7f ®_l b Phone Number: Email: i 1l�Ul �i Ltltct ��^�c>�_��l�i/iG�Lz,:f� lbt Contractor: ��L Address: City. State: Zip Code: Phone Number: nn Email: _) Contractor's License Number:-, G n T►= 9 Expiration: Type of Roofing Material: Grxr�l�ln ��tL i �Ls+���Al�l e Number of Existing Layers: Class of Roofing: A ® B ❑ C ❑ Replacing existing sheathing: Yes ❑ No oof tear off: ❑ Application over existing material: The following is recidifor NON-Residential Buildings: • Existing roof structure and material: b)(;10A Qw_ C ���n{�, --�� �411�i;�n j�,l j�,t)a-t loo; 3-4[i AC��)ed �Q c • Two copies of the installation specifications and U.L.listed roof assembly. • Occupancy of Building: Office Zoo I [ Retail Church Restaurant School frylCtvtytTrJtG�ilr`ibt� I hereby certify the above information is correct and that the construction o nd the occupancy and the use of the above described property will be accordance with the laws, rules and regulations of the State of Washington. The applicant will be responsible for providing a method of safely accessing roof for inspection. A final inspection and approval shall be obtained when the re-roofing is complete. Applicants Signature Date � l V, -S Print Applicants N FOR STAFF USE ONLY ReceiveM ?� _ _ AUG 0 9 2018 Permit J1 Ac pied By Amount Received Receipt# Date Received f f �.•: 'r 1'T �, ;� -.�'�'l1�ri��'�'j 1' - � r�.�!fy4Nr�fir.*'Y' 1 Z ' a� w N v � • •law EXPERIENCE THE CARLISLE DIFFERENCE S re l ex'" PVC Membrane Fully Adhered Roofing System The fully adhered system starts with a suitable surface upon which the Low-VOG PVC Bonding Adhesive or HydroBond-Water-Based PVC Bonding Adhesive is applied. � T Mechanically Fastened Roofing System The mechanically fastened system starts with approved insulation i being fastened with a minimum of 5 fasteners per 4'x 8'board.The PVC membrane is then mechanically fastened to the deck using HP-X- Fasteners and Piranha Plates—,or HP-XTRA Fasteners and Piranha XTRA Plates.Adjoining sheets of PVC membrane are overlapped over the fasteners and plates and joined together with a minimum 1Yz"-wide hot-air weld. Review Carlisle specifications and details for complete installation information. Overview Carlisle's Sure-Flex PVC is an advanced-formula,heat-weldable PVC Precautions thermoplastic membrane that is designed for long-term weatherability and » Sunglasses that filter out ultraviolet light are strongly recommended,as performance.The physical properties of the membrane are enhanced by a the membrane's white surface is highly reflective to sunlight.Roofing tenacious,weft-inserted polyester fabric that is encapsulated by thick PVC- technicians should dress appropriately and wear sunscreen. based top and bottom plies.The smooth surface of the PVC membrane » Smooth surfaces may cause slippery conditions due to frost and ice allows for a total-surface fusion and permanent weld,creating a consistent, buildup.Exercise caution during cold conditions to prevent falls. watertight,monolithic roof assembly.PVC can be used in adhered and mechanically fastened systems.The gray-colored bottom ply provides a Care muss be exercised when working close to a roof edge when visual confirmation of a proper weld during the la welding surrounding area is snow-covered,as the roof edge may not be P p 9 p g process. clearly visible. Features and Benefits n Use proper stacking procedures to ensure sufficient stability of the Wide choice of membrane sizes,thicknesses and colors materials_ Enhanced chemical resistance Exercise caution when walking on wet membrane.Membranes may be slippery when wet. � Energy efficiency Store PVC membrane in the original undisturbed plastic wrap in a ll Wide window of weldability cool,shaded area and cover with light-colored,breathable,waterproof » Flexibility in low temperatures tarpaulins.PVC membrane that has been exposed to the weather or Impact and puncture resistance contaminated with dirt must be prepared with PVC Membrane Cleaner u UV,ozone and oxidation resistance prior to clot-air welding. n Easy installation u Available in white,gray,and tan Installation With minimal labor and few components required,PVC is quick and easy to Received install.PVC systems are installed using an Automatic Heat Welder,making sheet welding fast,clean and consistent. AUG ® q 2018 800-479-6832 1 P.0_Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntee.com EXPERIENCE 1 DIFFERENCE ' sYhrr�� sus i sn�as Sure-Flex PVC Membrane Typical Properties and Characteristics 1 Radiative Properties for ENERGY STARO*, .. Physical Property I ASTM 04434 50-rail 60-rail 80-rail Roof RatingCouncil . , ` Requirement __ _ White Tan Gray Thicknessoverscnm,in.(nun) 0.016min 0-022 0.027(0,686) 0,037 Physical Property Test Method PVC PVC PVC ASTM D4434 optical method (0.40 (0,940) average of 3 areas ) (0.559) ENERGY STAR-E-903 Solar Spectrum 0.86 0.73 0.59 Welght,Ibsttt2(kghn7) No requirement 0.33 (1.61) 0.40 (1,95) 0,55 Initial Solar Reflectometer (2.68) Reflectance Breaking 6treuglh(MD x CD),flit/In 275 min 320 x 300 330 x 300(So 360 x 330 ENERGY STAR-E-903 Solar Spectrum 0.63 Pending Pending (kN/m)ASTM D751 grab method (48) (56 x 53)__x 55) _ (63 x 58) Solar Reflectance after Reflectometer Elangatlon break of reinfurcement(MD 25 min 30 x 3g 30 x 30 30 x 30 3 years (Uncleaned) _x CD),%ASTM D7- grab method _ Tearing strength(MD x CD),Ibf(N) 90 min 100 x 120 100 x 130 100 x 132 CRRC- ASTM C1549 0.86 0.73 0.59 ASTM 0751 pros.B,8 In x 81n. (400) (445 x 534) (445 x 578) (445 x 587) Initial Solar Low temperature bead,ASTM PASS PASS PASS PASS Reflectance 02135,no cracks 5xat-40°C (-401C) (-40oc) (40113) Unear - CRRC- ASTM C1549 0.63 0.60' 0.48` 01204 dimensionalchange,%ASTM m0.5 max 0.4 0.4 Solar Reflectance D1204,6 hours att176"P t1.A (Uncleaned) Ozone resistance,no cracks 7x ASTM PASS PASS PASS PASS after 3 years D1149,100pphm,168 hrs CRRC- ASTM C1371 0.89 0.86 0.85 Water absorption resistance,mass% ±3.0 max 2.0 20 ?_A Initial Thermal ASTM D570,166 hours at 156^F xater Emittanre Reid soam strength,mflln.(kN/m) No reanaremnnl 25(4.4)min 25(4.4)min 25(4,41 min CRRC ASTM C1371 0.87 0.82` 0.81' ASTM 01676 tested in peel 60110.51 Go(10.5)typ, 60 it 0.51 typ _ typ. Thermal Emittance (uncleaned) Water vapor permeance,Perms, No requirement 0.10 max 0.10 max OAD max after 3 years ASTM E96 proc B 0.05 typ 0.05 typ 0.05 typ Solar Reflective Index ASTM E1980 108 89 69 Puncture reslstanco-Federal,lbf(kN)i No requirement 260 320 380 (SRI) FTM 101C,method 2031 Puncture resistance-Dynamic,J 20(14.71 PASS PASS PASS Solar Reflective Index ASTM E1980 75 70' 53' (N-Ib0 ASTM 05635 (SRI)SRI after 3 years Puncture resistance-Static,Ibf IN) 33(145) PASS PASS PASS ASTM D5602 Rapid Ratings Xenon-Arc resistance,no i PASS PASS PASS PASS cracks?crazing lox,ASTM G155 0.35 Wrm'at 340-nm,63°C B.P.T. LEED Information 12,600 kJyml total radiant exposure 10,000hOtirs _ Pre-consumer Recycled Content 10% Properties after heat aging 90 min 90 min 90 min 90 min l - ASTM D3045,56 daysat 176°F 1 90 min 90 min 90 min 90 min Post-consumer Recycled Content 0% Bongalgstroird., %retained Manufacturing Location Greenville,IL FJongalian rairll.,%retained 9 Typical properties and characteristics are based an samples tested and are not guaranteed for all Solar Reflectance Index(SRI),Initial White:108,Tan:89,Gray:69 samples of this product.This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. Supplemental Approvals, Statements and Characteristics D Sure-Flex PVC meets or exceeds the requirements of ASTM D4434 Standard Specification for Poly(Vinyl Chloride)Sheet Roofing.Sure-Flex PVC is classified as Type III and/or Type IV as defined by ASTM D4434. » Sure-Flex reinforced PVC was tested for dynamic puncture resistance per ASTM D5635-04 using the most recently modified impact head. 50-mil thick membrane was watertight after an impact energy of 22.5 J (16.6 ft-)bf),which passes the ASTM 04434 requirement. >1 Sure-Flex reinforced PVC was tested for static puncture resistance per ASTM D5602-98 and exceeded 33 Ibf(145 N),which passes the ASTM 1 D4434 requirement. 800-479.6832 I P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntec.com 11.29.11 T3 2017 Carlisle. Carlisle.HydroRond."sure-Flex,HP-X F.uteri and Piranha Plates are trademarks of Carlisle REPAINT CODE:605245.'Sure Flex PVC Membrane Product Data Sheet" ENERGY STAR is a registered trademark awned by the US Govemment.*ENERGY STAR qualification is only valid in the US LEED is a registered Trademark of the U S Green Oulluri Councll 11 '.-lecurShield' HD POLYISO Insulation -qqqN Product Characteristics pppppppPanel sizes: - 4'x 8'(1220 mm x 2440 min) 4'x 4'(1220 min x 1220 mm) * Panel thickness:Y2'(13 mm) Weight: 0.343 Ibs/sq.ft, 11 Ibs(4.99 kg)per 4'x 8'panel 5.5 Ibs(2.49 kg)per 4'x 4'panel Installation Mechanically Attached Single-Ply Systems Each SecurShield HD panel must be secured to the substrate with approved Overview Carlisle fasteners and plates.Butt edges and stagger joints of adjacent panels.Install the roof membrane according to Carlisle specifications. Carlisle's SecurShield HD Fnlyiso Insulation is a rigid roof insulation panel composed of a high-density,closed-cell polyisocyanu rate foam Fully Adhered Single-Ply Systems core laminated to a prernium-performance,coated glass facer(CGF). Carlisle's SecurShield HD may be secured to the roof deck using Carlisle's Suitable for both re-roofing and new construction applications, FAST`"and Flexible FAST adhesive, UiyBond500r11 insulation adhesive, SecurShield HD is specifically designed for use as a cover board over a fasteners and plates,or hot asphalt(appropriate to the deck type). variety of substrates.SecurShield HD delivers an R-value of 2.5,which For adhesive coverage or fastening patterns and requirements,please is significantly higher than roof cover boards made with other materials contact Carlisle's Design Services group. Butt the edges of the insulation such as wood fiber or gypsum_ panels and stagger the joints. Install the membrane according to Carlisle Features and Benefits specifications. Review Carlisle specifications and details for complete installation » High-density insulating cover board information. :> Exceptional protection against hail,rooftop traffic,mold,and moisture ;> High-density formulation achieves FM severe hail rating(SN) Codes and Compliances n 2 times higher R-value than wood fiber hoards ASTM C1289,Type II,Class 4,Grade 1 (109 psi max.) >� » Compatible with all Carlisle single-ply roofing systems(Except Ballast) International Building Code(IBC)Section 2603 UL Standard 790,263 and 1256:Component of Class A Roof Systems » Coated glass facer provides strong bond far adhered roofing applications (refer to UL Roof Materials'system directory) FM Standards 4 4 5 014 47 0:Class 1 approval for steel roof-deck Productivity Boosting Features and Benefits. constructions(refer to FM RoofNav) Lightweight and easy to cut;handle,and » California Codes of Regulations,Title 24,Insulation Quality Standard install-no crumbling of material License#TI-1418 » 5 times higher R-value than gypsum cover _ >> rhird-party certification with PIMA Quality Mark for Lang-Term boards Thermal Resistance(LTTR)values * Vs the weight of gypsum cover boards � r � CAN/ULC S704,Type 3,Class 2 Received :} Florida Building Code Approval AUG 0 9 HIS �1b21zt 300-479-6832 1 R0.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntee.com EXPERIENCEs RLISLE DIFFERENCE loop;If-if Sl'fVTEC SYSTFr\,r. SecurShield HD POLYISO Insulation Precautions Insulation must be protected from open flame and kept dry at all times.Install Typical Properties and Characteristics only as much insulation as can be covered the same day by completed roof- Physical Property Test Method Value covering material.Carlisle will not he responsible for specific building and Compressive Strength ASTM D162.1 109 psi max root design,for deficiencies in construction or workmanship,for dangerous Dimensional Stability ASTM D2126 <0.5%linear change conditions on the jobsite.or for improper storage and handling.Technical (7 days) specifications shown in this literature are intended to be used as general Water Absorption ASTM C209 <1%volume guidelines only and are subject to change without notice.Call Carlisle for R-value ASTM C518 2.5 more specific details or refer to PIMA Technical Bulletin No.109:Storage and Thickness Y2 Handling Recommendations for Polyiso Roof Insulation, Service Temperature 260°F(1261G)or less Resistance to Mold ASTM D3273 Passed Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product.This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. Information Pre-consumer Recycled Content 0% Post-consumer Recycled Content 9% Manufacturing Locations Smithfield,PA Franklin Park,IL Tooele,UT Montgomery,NY Lake City,FL Terrell,TX, Puyallup,WA Solar Reflectance Index(SRI) N/A 04 11 19®2alB Carlisle. 800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 I www.carlislesyntec.com GaMft HEPRINT CODE:605075-"SecurShleld UD Pelyiso Product Data Sheet" ulyBondSDG is a registered Imdemark at MI LEEp qhI HIM*FAST and FAST are trademarks ot canisle lyESIM)Irademark al the D.S.Green Buiimnu.,aunt DIFFERENCEEXPERIENCE THE CARLISLE s SYr\1_rF0 SY 5T 7B HPA Fastener Precautions n The strength of different roof decks varies widely and can be adversely affected by moisture and other conditions.Therefore,Carlisle recommends conducting a fastener pull test to help evaluate deck conditions and fastener suitability. Care must be taken not to overdrive the fastener, Eye protection is recommended during drilling and installation. InformationPackaging Size Weight/Carton Thread Length Packaging Inches(mm) (Kg) Inches(mm) Fasteners/Carton 2(50) 20 Ibs(9.08) Full 1,000 3(75) 29 Ibs(13.16) Full 1,000 Overview 4(100) 38 lbs(17,25) 3(76) 1,000 Carlisle's HP-X Fastener is a specialized,high performance fastener 5(125) 24lbs(10.89) 4(102) 500 designed to secure Carlisle single-ply membrane and insulation.The 6(150) 28 Ibs(12,71) 4(102) 500 HP-X Fastener can be used on steel decks(20-gauge[0.91 mmi or 7(175) 34 Ibs(15.44) 4(102) 500 22-gauge[0.76 mm]or wood[minimum 11/32"[12 mm]COX plywood]). - - The HP-X Fastener is designed to offer an optimum combination of 8(200) 38 Ibs(17.25) 4(102) 500 driving performance,back-out,and corrosion resistance witti excellent 9(230) 42lbs(19.07) 4(102) 500 pull-out performance. 10(255) 47 Ills(21.33) 4(102) 500 11(280) 52 ibs(23.61) 4(102) 500 Features and Benefits12(305) 56 Ibs(25.42) 4(102) 500 » Oversized heavy shank and#15 thread diameter for enhanced 14(355) 32 Ibs(14.52) 4(102) ?5r! pull-out resistance 16(405) 38 Ibs(17.25) 4(102) 250 Miniature drill paint penetrates decks quickly and contributes to exceptional resistance to back-out as well as pull-out Deep buttress threads further increase pull-out and back-out Typical Properties resistance Head #3 Phillips Truss Head Excellent corrosion resistance,surpassing the FM4470 corrosion test .435"(11.04 mm)diameter Thread .265"(6.73 mm)diameter Installation Shank 202' (5.13 mm)diameter 1. No pre-drilling is necessary for wood and steel decks.Simply insert Coating CR-10 the HP-X Fastener through an approved Carlisle plate and install Typical properties and characteristics are based on samples tested and are not guaranteed with a standard clutch drive electric screw gun(0—2,500 rpm). for all samples of this product.This data and information is intended as a guide and does not 2. Optimum fastener performance is achieved when the fastener is reflect the specification range for any particular property of this product. installed perpendicular to the deck and into the top flutes of a steel deck. Review Carlisle specifications and details for complete installation Received information. AUG 0 9 H18 - _.- PArZ►zI Amw 800-479-6832 I P.O. Box 7000 l Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntec.com 0714.16 0 7016 Carlisle, Carlisle,Sure-Weld and Sure-Flex are Irademarks of Carhsoe- WEO ONLY:CS1-7066:"HP-x Fastener Product Data Sheet' DIFFERENCEEXPERIENCE THE CARLISLE SYrVTEC:, SY.STti+1�1S Sure-Flex"' PVC Low-VOC Bonding Adhesive Application I. The surface on or against which adhesive is to be applied shall be clean,smooth,dry,free of fins,sharp edges,loose and foreign materials,oil and grease.Depressions greater than W(6 mm) should be feathered using epoxy,mortar or other approved patching material_All sharp projections shall be removed by sweeping, blowing or vacuum cleaning. rswcr.�rr _ - 9 9 2. After thorough stirring(minimum 5 minutes),apply PVC Low-VOC Bonding Adhesive to substrate and membrane using a 9"(229 mm) p� medium nap roller.Application shall be continuous and uniform, ° avoiding globs or puddles.An open time of 5 to 50 minutes(based on drying conditions)is recommended before assembly.PVC Low- VOC Bonding Adhesive must be allowed to dry until it does not string or stick to a dry finger touch.The membrane and substrate will be dry(non-tacky)to the finger touch_Any coated area that has been Overview exposed to rain should be allowed to dry and then recoated. Do not Sure-Flex PVC Low-VOC Bonding Adhesive is a high-strength solvent- apply adhesive to splice areas to be hot-air welded. based contact adhesive that allows bonding of PVC and KEE membranes 3. Roll the membrane onto the adhesive-coated substrate while to various porous and non-porous substrates.It is specially formulated avoiding wrinkles.Immediately brush down the bonded portion using a blend of VOC-exempt and non-exempt solvents to be in compliance of the sheet with a soft-bristle push broom or a clean dry roller with the state of California Clean Air Act of 1988(updated in 1997)and applicator to achieve maximum contact. as further regulated by California's Air Quality Control Districts listing Review Carlisle specifications and details for complete application VOC limitations.This product also meets the<250 gpl VOC content requirements of the OTC Model Rule for Single-Ply Hoofing Adhesives. information. Features and Benefits Precautions > High-strength adhesive that allows quick bonding Review the applicable Material Safety Data Sheet for complete safety information prior to use. » Can be easily applied with a medium nap rollerPVC Low-VOC Bonding Adhesive is EXTREMELY FLAMMABLE.It » Provides excellent adhesion between various substrates and PVC contains solvents that are dangerous fire and explosion hazards when and/or KEE membranes exposed to heat,flame or sparks.Do not smoke while applying.Do not use in a confined or unventilated area.Vapors are heavierthan air and Coverage Rate may travel along ground or may be moved by ventilation and ignited by 60 ft2(5.6 Wz per gallon finished surface.Coverage rates are average and pilot lights,otherflames,sparks,heaters,smoking,electrical motors, may vary due to conditions on the jobsite.Parous surfaces and substrates static discharge,or other ignition sources at locations distant from may require more bonding adhesive than the typical coverage rate. material handling point.All containers should be grounded when material is transferred from one container to another.A red caution label is Mixing required when shipping.A fire extinguisher should be available.In case Stir thoroughly until the adhesive is uniform in color.Minimum 5 of fire,use water spray,foam,dry chemical or carbon dioxide.Do not minutes stirring is recommended. use a solid stream of water because it can scatter and spread the fire. Avoid breathing vapors.Keep container closed when not in use. Use with adequate ventilation.If inhaled,remove to fresh air. It not breathing,perform artificial respiration.If breathing is difficult,give oxygen.Call a physician immediately.During application,efforts must 800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntee.com EXPERIENCE CARLISLE DIFFERENCE SY'NTEC SYSTF_�.sP.S Sure-Flex PVC Low-VOC Bonding Adhesive be made to prevent fumes from entering the building via air ventilation Typical Properties and Characteristics ducts.Do not place open containers or mix adhesive near fresh air intake units.When possible,shut down or seal off the closest units. Base Synthetic rubber a if swallowed,DO NOT INDUCE VOMITING.Call a physician immediately. Color Pale yellow to orange to amber Sands 23.6-29.6% n Avoid contact with eyes.Safety glasses or goggles are recommended. If splashed in eyes,immediately flush eyes with plenty of clean water Flash Point -4°F(-20°C)SETA for at least 15 minutes.Contact a physician immediately. Brookfield viscosity 1500—4500 centipoises „ Avoid contact with skin.Wash hands thoroughly after handling.In case Average Net Weight 6.9-7.7 Ibs/gal(0.8—0.9 kq/l) of contact with skin,thoroughly wash affected area with soap and Packaging 5-gal pail water.Contact physician if irritation persists. Shelf Life 1 year Note:Permeation-resistant gloves(that meet ANSI/ISEA 105-2005) Typical properties and characteristics are based on samples tested and are not guaranteed are recommended to be worn when using this product to protect hands for all samples of this product.This data and informatian is intended as a guide and does not from Irritating ingredients. reflect the specification range for any particular property of this product. » Do not thin PVC Low-VOC Bonding Adhesive.Thinning will affect performance.Excessively thick or gelled material should be discarded. LEEW Information u Jobsite storage in excess of 90°F(32'C)may affect product shelf life. Pre-consumer Recycled Content 0% Should the PVC Low-VOC Bonding Adhesive be stored at temperatures Post-consumer Recycled Content 0% lower than 60'F(15°C),restore to room temperature prior to use. UOC Content <250 g<I n Opened containers of PVC Low-VOC Bonding Adhesive should be used Manufacturing Location Carlisle,PA within 48 hours.Adhesives will begin to thicken after this point,making it difficult and eventually impossible to control applied thickness.In hot weather,do not leave sealed containers on roof for prolonged periods of time.In cold weather,keep material at roam temperature until ready to use-Stir adhesive occasionally while using, > Adhesive must be allowed to dry thoroughly.If membrane is mated with the substrate prior to the adhesive being dry,blistering will occur and will not subside over time. KEEP OUT OF REACH OF CHILDREN. Received AUG 0 9 2018 1��"IZI�I 800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7059 1 www.carlislesyntec.com G9.2b13®201a Cadisle Carlisle and Sure-Flee are trademarks of Carlisk) REPRINT CODE 6056Gri-"Sure-Flex PVC Low-VOC Bonding Adhesive Product Bata Sheet' LEED is a registered trademark of the u.5 Green Building Council EXPERIENCE THE CARLISLE DIFFERENCE 1rJ#A;:f Af aF SYNTEC SYSTEM r.S Sure-Flex"' PVC Certified Coated Metal Aceassary Installation I. Install Sure-Flex PVC Coated Metal with a W'to (3-6 mm)gap between adjoining sections. 2. Install 2"(5 cm)-wide foil tape over joints. 3. Heat-weld a 6"(15.5 cm)-wide piece of Sure-Flex PVC Flashing over each joint. 4. Position Sure-Flex PVC membrane and heat-weld to the Sure-Flex PVC Coated Metal with a minimum 11/z"(4 cm)weld. Review Carlisle specifications and details for complete installation information. Precautions a Store Sure-Flex PVC Coated Metal in a coal,shaded area,and cover with light-colored,breathable,waterproof tarpaulins.Sure-Flex PVC Coated Metal that has been exposed to the weather must he prepared Overview with Carlisle's PVC Membrane Cleaner prior to hot-air welding. Carlisle's Sure-Flex PVC Coated Metal is a galvanized steel sheet with a " Do not install Sure-Flex PVC Coated Metal in such a way that the laminate of non-reinforced Sure-Flex PVC flashing.The sheet is cut into membrane side is in direct contact with asphalt,coal tar pitch, the appropriate width and used to fabricate metal drip edges or other polystyrene,or other petroleum-based products. roof perimeter edge profiles.Sure-Flex PVC membrane may be welded directly to the coated metal,eliminating the need to strip in the metal with a separate piece of membrane.The metal is available in 4-foot by 10-foot Typical Properties ' Characteristics (1.2 in by 3.1 m)sheets and comes packaged 10 sheets per pallet. Sheet Size 4 foot by 10 foot(1.2 m by 3.0 m) Carlisle's Sure-Flex PVC Coated Metal is part of the Certified Fabricated weight 1.1 IblfV(5.4 kgfmz) Accessory(CFA)program.Certified Fabricated Accessories are the Color white,Gray and Tan only factory-fabricated PVC accessories that meet the stringent quality Flashing Thickness 0.035 inches(0.9 mm)nominal tolerances required to be included in a Carlisle warranted roofing system. Steel Thickness 0.024 inches(0.6 mm)nominal(24 gauge) PVC coated aluminum and stainless steel are available in 4'x 10'sheets on - - - a special order basis in white,gray,and tan.Contact customer service for Steel Type Hot Dipped Galvanized Steel-G90 minimum orders and lead times. Packaging 10 sheets per pallet Typical properties and characteristics are based on samples tested and are not guaranteed Features and Benefits for all samples of this product.This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. Allows direct welding of Sure-Flex PVC membrane to the coated metal, eliminating the need to strip in edging with additional membrane ]3 Easy to cut and form to create a variety of edge sizes and profiles ° Information u Practical and cost-effective way of flashing roof edges Pre-consumer Recycled Content 0% Available in white,gray,and tan colors Post-consumer Recycled Content 0% � Manufacturing Location Scranton,PA Matches membrane color to create a uniform look Solar Reflectance Index whde:111 Gray:43 Tan:50 300-479-6032 1 P.O.Box 7000 1 Carlisle, PA 17013 1 Fax:717-245-7053 1 www.carlislesyntec.com 09 0R.16 0 2016 Carlisle, REPRINT CDnE;G05639-'Sure-Flex PVC Coated Metal Product Data Sheet" Carlisle and Sure Rex are trademarks of Carlisle EXPERIENCE CARLISLE DIFFERENCE LM .s�-nr•r�c .s�sr-�n.ra re _ d ex PVC `jertlfied r Molded Pi Fl i' Fpacic oesedy t'� ���°�� fyccessory Installation 1. Cut Pipe Seal between double-ribbed cutting guides,one size smaller than the pipe diameter. Do not cut off raised ring. 2. Pull Pipe Seal over pipe until base flange is in contact with the membrane.It may be necessary to apply heat to the top portion of the Pipe Seal to allow installation over the pipe. 3. Mark pipe around the top of the Pipe Seal. 4. Pull Pipe Seal upwards on pipe until mark on the pipe is visible. 5. Apply Universal Single-Ply Sealant below the mark that indicates the top of the installed Pipe Seal. 6. Pull Pipe Seal back down over pipe and into position. Overview 7. Heat-weld the Pipe Seal base flange to deck membrane. B. Install a stainless steel universal clamping ring to provide constant Carlisle's Sure-Flex PVC Pipe Seals are injection-molded,pre-formed compression of the sealant. [lashings for pipes.75"(19 mm)to 8"(203 mm)in diameter.This labor- savin Review Carlisle specifications and details for complete installation g accessn ry provides a quick and reliable way to waterproof round information. pipe penetrations. Sure-Flex PVC Pipe Seals are part of Carlisle's Certified Fabricated Precautions Accessary(CFA)program.Certified Fabricated Accessories are the only factory-fabricated PVC accessories that meet the stringent quality Remove all lead and other flashing. tolerances required to be included in a Carlisle warranted roofing system. Temperature of pipe must not exceed 140oF(60'C). » Install a minimum of four fastening plates around pipe penetrations. Features and Benefits Position fastening plates around the penetration so they are covered by Provides a reliable method of waterproofing round pipe penetrations the Pipe Seal flange.A minimum 1.5"-wide weld must be maintained Provides substantial labor savings compared to field-fabricating from around the outer edge of the flange beyond the plates.If fastening non-reinforced flashing plates cannot be installed in a manner to allow a minimum 1.5"weld, the plates must be placed outside the Pipe Seal flange and covered > Provides a more consistent appearance than field-fabricated pipe with a reinforced Sure-Flex membrane overlay. (lashings u Store Pipe Seals in a cool,shaded area and cover with light-colored, Double-ribbed cutting guide facilitates easier,smoother,and breathable,waterproof tarpaulins.Sure-Flex Pipe Seals or membranes straighter cuts that have been exposed to the weather must be prepared with PVC » Rib design holds the clamp in the proper position Membrane Cleaner prior to hot-air welding. Typical PropertiesP Characteristics Productivity Boosting Features and Benefits: Sizes 3/4"to B"O.D.Pipe(19 to 203 mm) Packaging 8 per box Up to 60%labor savings compared to — -- — traditional field fabrication ` , Weight(each) 0.55 Ibs(0.25 kg) n Quick and simple installation with no Material PVC compound Received stretching required ) Color White,Tan,and Gray Provides a consistent,finished a Pp earance ' t ?ypical properties and characteristics are based Al.)on samples tested and are not suarnn�J 9 2018 Wall samples of this product This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. 112-At/2l 21 is � -I//� 800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.earlisiesyntec.com EXPERIENCE ■ DIFFERENCE ' . srrvrFc srsrsvrs Sure-Flex PVC Molded Pipe Flashing Please use the chart below to cross-reference your pipe size with the proper step to cut as shown. Copper • . Nominal Tulle Size T '/e" l" 1 W. t 1h" 2` 21h" 3" 4u 5" 6" 8" Pipe O.D. 88 1.13 1,38 1.63 2.13 2.63 3.13 4.13 5.13 6.13 N/A Step of Boat Used I 1 1 1 1h 2 T2� 3 4 5 6 N/A Schedule 40/80 Steel Pipe - PVC Standard - Polyethylene Pipe IPS Nominal Tube Size 7A" 1" 1 1/4" 1 1h" 2" 21h" 3" 41' 5" 6" 8" Pipe Q.D. 1.05 1.32 1.66 1.90 2.38 2.88 3.50 4.50 5.56 6.63 8.63 Step of Boot Used t 1 1 1h 1 'h 2 3 3 4 5 6 8 •- Pit Class A&Spun 100-250 Pit Class B,C&0 Nominal Tube Size 2" 3" 4" 6" B. 2" 3" 4" 6" 8" Pipe O.D ?`10 3.96 4.80 6.90 9.50 NIA 3.96 5,00 7.10 9.30 Step of Boot Used 2 4 5 G NIA N/A 4 5 6 NSA Sewer - Soil • r- PVC Plastic SDR 35&41...Cast iron Soil Pipe no hub...service weight&extra heavy Nominal Tube Size 4" 4" 4" W. 6" 6" 6" 6" 8" 8" 811 8" Pipe O.D. 1 4.22 4.38 4.30 4,62 6.28 6,30 6.30 6,62 8.40 8,38 8.38 8.75 Step of Boot Used 4 4 4 4 6 6 6 6 a 8 8 8 Conduit Nominal Tube Size 3'4" 1" 1 1/d' 1,h" 2" 21h" 3" 3,h" 4" Pipe O.D. .922 1,16 1.51 1.74 2.19 2.88 3.50 4.00 4.50 Step of Boot Used 1 t I 1 'i 2 3 3 4 4 Conduit IMC Nominal Tube Size 1 1h" 2" 21/2 311 31/z" 4" Pipe O.D. 1.02 1.29 11,63 1.88 2.36 2.85 3.47 3,97 4.46 Step of Boot Used 1 1 1 'h 1 'h ?_ 3 3 4 4 Conduit Rigid Nominal Tube Size 3W 1° 1 1/n" 1 h" 2" 2 1h" 3" 31h" 4" 5" Pipe O.D. I 1,05 1.32 1,66 1.90 2.37 2.87 3.5 4 4.5 5.56 Step of Boot Used 1 I 1 h 1 V2 2 3 3 4 4 5 I .. 800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntec,com 07 1 D,1II®2018 Carlisle REPRINT CODE:605152 'Sure-Flex Pipe Seals Product Data Sheet" Carlisle and Sure-Flex are trademarks of Carlisie EXPERIENCE ! CARLISLE DIFFERENCE ' SYIV_rEC SYSTEMS Sure-Flex"' PVC 6ertined Inside Corners ,FAccessory Installation I. Position the PVC Inside Corner into the corner,begin welding at the innermost corner point and work away from the corner. 2. Use the edge of the roller to crease the corner flashing into any membrane step-off to create a proper seal. 3. Probe all welded edges of the corner once the material has been completely cooled to ensure watertight performance. Review Carlisle specifications and details for complete installation informatlan. Precautions v Store PVC Inside Comers in a cool,shaded area and cover with light- colored,breathable,waterproof tarpaulins.PVC Inside Corners or PVC membranes that have been exposed to the weather or contaminated Overview with dirt must be prepared with PVC Membrane Cleaner prior to hot-air Sure-Flex PVC Inside Corners are pre-molded and are used forflashing welding. the inside comers on a variety of details.Installation is fast and easy with no cutting or stretching required.This product is available in white,gray and tan. Typical Properties and Characteristics PVC Inside Comers are part of the Certified Fabricated Accessory Thickness i .060"(1.52 mm) (CFA)program.Certified Fabricated Accessories are the only factory- Packaging 12/bag fabricated PVC accessories that meet the stringent quality tolerances required to be included in a Carlisle warranted roofing system. Material Injection-molded non-reinforced PVC flashing Color White,Gray and Tan Features and Benefits �+ Forms easily into out-of-square comers that are not exactly 90 degrees LEEDO Information Provides substantial labor savings compared to field-fabricating Pre-consumer Recycled Content 0% the flashing detail from non-reinforced flashing Post-consumer Recycled Content 0% More consistent appearance than inside corners field-fabricated Manufacturing Location Bloomingdale,IL from flashing Solar Reflectance Index(SRI) White:111 Gray:43 Tan:50 Received AUK A ,, 2nI8 800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntec.com 11 22 13®2013 Cadlsle Carlisle and Sure-Flex are trademarks at Carlisle. REPRINT CODE:605148-"Sure-Flex PVC Inside Corners Pmducl Data Sheel" LEED Is a registered trademark of the D S.Green Building Council EXPERIENCE THE CARLISLE DIFFERENCE SYNTEC SY;�.TEM..r- Sure-Flex"' PVC Certltfed Fabrlcated� T—Joint Covers Accessory Installation 1. If membrane has been exposed to the weather,clean splice intersection area with PVC Membrane Cleaner. 2. Use a lower temperature setting on the heat welder than that used for welding reinforced membrane.(Typically a setting of 6-7 on a l scale of 10 is appropriate for welding PVC T-Joint Covers.) 3. Center the PVC T-Joint Cover over the splice intersection,begin welding at the center point and work towards the outside.Use the edge of the roller to crease the PVC T-Joint Cover into membrane step-offs to achieve a proper seal. 4. Once the weld area is completely cool,check all splices for voids and cold-welds with a seam probe.Make any needed repairs. Review Carlisle specifications and details for complete installation intom7ation. Overview Sure-Flex PVC T-Joint Covers are used to seal step-offs at splice Precautions intersections.Installation is mandatory on all 60-and 80-mil PVC systems D The PVC T-Joint Cover is not intended for use to overlay fasteners and and on 50-mil systems where step-offs have not been property sealed.PVC plates as this requires the use of reinforced membrane. T-Joint Covers are formed from 60-mil white and 40-mil gray and tan non- reinforced PVC cut into a perfect 4-5"-diameter circle.Packaged in a box " Store the PVC T-Joint Covers in a cool,shaded area and cover with containing 100 covers.Available in white,gray and tan. light-colored,breathable,waterproof tarpaulins.PVC T-Joint Covers that have been exposed to the weather prior to use must be prepared Carlisle's PVC T-Joint Covers are part of the Certified Fabricated Accessory with PVC Membrane Cleaner before hot-air welding. (CFA)program.Certified Fabricated Accessories are the only factory- fabricated PVC accessories that meet the stringent quality tolerancesTypical _ required to be included in a Carlisle warranted roofing system- Sizes 4.5"(114 mm) Features and Benefits Thickness 0.060"(1.52 mm)White 0.040"(1.02 mm)Tan and Gray » More consistent appearance than hand-cut flashing Packaging 100/box u Provides substantial labor savings compared to field-cut T-Joint covers Weight(per box) 3.5 Itis(1.6 kg) > Provides a more professional appearance than field-fabricated covers Material Non-Reinforced PVC r Seals channels at spline intersections created by seam step-offs Color White,Gray and Tan Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product.This data and information is intended as a guide and does not reflect the specificalion range for any particular property of this product. LEED"Information Pre-consumer Recycled Content + 0% Post-consumer Recycled Content 0% Manufacturing Location Eugene,OR Bloomingdale,IL Solar Reflectance Index(SRI) White:111 Gray:43 Tan:50 800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www,carlislesyntec.com 11 22.13 0 2013 Carlisle Carlisle and Sure Flex are trademarks of Carlisle REPRINT CODE:605150-'Sure-Flex PVC T-Joint Covers Product Data Sheer' LEFD is a registered Irarlenurk of the 115 Green eruldurg Couuui EXPERIENCE THE CARLISLE DIFFERENCE 131"PlITEc Sa ire-Flex... PVC Non-Reinforced Flashing Precautions r Review the applicable Safety Data Sheet for complete safety information prior to use. Sunglasses that filter out ultraviolet light are strongly recommended,as white surfaces are highly reflective.Roofing technicians should dress appropriately and wear sunscreen. H Store PVC Flashing in a cool,shaded area and cover with light-colored, breathable,waterproof tarpaulins.PVC Flashing that has been exposed =" to the weather for approximately 7 days or longer must be prepared with PVC Membrane Cleaner prior to hot-air welding. t TypicalProperties ane Characteristics Properties ASTM Test Method Specification Overview Tolerance on nominal Thickness ASTM D751 8 Carlisle's Sure-Flex PVC Non-Reinforced Flashing is a 60-mil thermoplastic Weight,Ib/ftl(kg/mz),typical 0.441b1ft7 polyvinyl chloride(PVC)membrane enhanced with KEE HP plasticizer for Breaking strength,min,Ibf/in.(N) ASTM D751 Proc.B 167.60(MD), increased longevity and enhanced performance-Available in white,gray, 142.88(CD) and tan,PVC Flashing is offered in 12"and 24"by 50'rolls.When the use Elongation at Break,min.,% ASTM 9751 Proc,B 399.60(MO), of prefabricated accessories is not feasible,PVC Flashing can be used to 420.27(CD) create inside and outside comers,field-fabricated pipe flashings,curb Tear strength,min.,Ibf/in(kN/m) ASTM 01004 10 corners,and scuppers. Heat aging:28 days%Retention ASTM 04434 90 Features and Benefits Resistance to Xenon-Arc weathering ASTMD4434 "No cracking/ -Xenon-Arc,5,040 kJ/m2 total crazing, n KEE HP enhances flexibility,making it easier to field-fabricate details radiant negligihle --Exposure,visual condition at 7X discoloration" KEE HP increases weatherability for added protection at critical — —— — transition areas and maximum longevity Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this producL This data and information is intended as a guide and does not » Superior weldability allows for consistent,high-quality seams in reflect the specification range for any particular property of this product. penetrations and other critical roof areas >t Available in white,gray,and tan to match Carlisle's Sure-Flex PVC and LEED*1 Information KEE HP membranes Pre-consumer Recycled Content 10% Installation Post-consumer Recycled Content 0% 1. PVC Flashing is used to flash various roofing system details and Manufacturing Location Mountain Top,PA penetrations.The specific installation method will vary based on Solar Reflectance Index 111(white),69(gray),81(tan) the situation. 2- Use a lower temperature setting on the heat welder than when welding non-reinforced PVC membrane.Typically,a setting of 7 on a scale of 10 is appropriate for welding PVC Flashing. Received 3. Use the edge of the roller to crease the flashing into any membrane F� step-offs for a proper seal. AUG 0 9 ?0 1 8 Review Gadisle specifications and details for complete installation %n I ? information. Y��""//II 800-479-6832 1 P.O.Box 7000 i Carlisle, PA 17013 1 Fax:717-245-7053 i www.carlislesyntec.cam 06.23.17 rt9 2017 Carlisle. Carlisle and Sure-Flax are trademarks al Carlisle nEPRINT CODE:600319-"Sure-Flex PVC Non-Relnforred Flashing Product Data Sheer" Lr_re is a regislered tmderramrk of the 0 S Green Building Council EXPERIENCE THE CARLISLE DIFFERENCE / sr,�t�-�r; .���s•r�,�r Sure-Flex"' PVC CFardd Walkway Rolls brica ted Accessory V 3_ Using an automated welder,weld all four sides of the PVC Walkway Roll to the membrane.(Typically the same speed and temperature settings will be used for this procedure as for welding membrane to membrane.A test weld is always recommended prior to performing welds to the installed membrane.)A hand-held welder may be utilized;however,productivity will be decreased. Review Carlisle specifications and details for complete installation information. Precautions PVC Walkway Rolls are a maintenance item and are not covered under the Carlisle membrane systems warranty. » This product is to be used as a walkway only and is not designed as a Overview perimeter warning line or a substitute for ballast.PVC Walkway Rolls Carlisle's Sure-Flex PVC Heat Weldable Walkway Roll is designed to protect cannot be installed within 10' (3 m)of the roof perimeter. the PVC membrane in those areas exposed to repetitive foot traffic and 0 If possible,allow the PVC Walkway Roll to relax prior to welding in place. other hazards. The PVC Walkway Rolls provide a defined path to walk on for those Packaging servicing and repairing HVAC systems and other rooftop equipment found Each roll individually bagged.Fourteen rolls per skid. on low-slope roofs. Size:36"wide x 60'long(91.4 cm x 18.3 m) Walkways must be installed at all traffic concentration points(i,e. Weight:95 Ibs(roll) roof hatches,access doors,rooftop ladders,etc.)regardless of traffic Color:Gray frequency.Walkways must also be installed if regular maintenance(once a Thickness:80 mils month or more)is necessary to service rooftop equipment. Carlisle's PVC Walkway Rolls are part of the Certified Fabricated Accessory Typical Propertiesand Characteristics program.Certified Fabricated Accessories are the only factory- Typical fabricated PVC accessories that meet the stringent quality tolerances Physical Property Test Method Properties Maximum required to be included in a Carlisle warranted roofing system. _ Minimum Dimensional Conformance ASTM D412 0.072(1.83) 0.088(2.24) Features and Benefits Thickness,in.(trim) » Increased slip resistance created with a diamond tread pattern Density,lbs./1113 wrlcm') ASTM D792 80.5(1.29) 84.3(i.35) Enhanced PVC formulation Tensile Strength,psi(Mils) ASTM D63B 600(4.1) :> Superior weathering package for long-term performance Tear Strength,Ibt/in(kNim) ASTM D624 100(17.5) Typical properties and characteristics are based on samples tested and are not guaranteed Installation for all samples of this product.This data and information is intended as a guide and doss not reflect the specification range for any particular property of this product. 1. Use PVC Membrane Cleaner to prepare the membrane to be welded to the walkway material. LEEW Information 2. Position the PVC Walkway Rolls, Cut the PVC Walkway Rolls into Pre-consumer Recycled Content 45% maximum 10' lengths and position with a minimum 1"gap between adjacent pieces to allow for water drainage.Cut the PVC Walkway Post-consumer Recycled Content 20% Roll so a 4"minimum gap is created over any field splices.(As the Manufacturing Location Mountain Top,PA aKachme.ntof the walkway to the membrane is permanent,this will Solar Reflectance index(SRI) N/A allow ac'esstto the field seams.) -- 800-479-6832 i P.0_Box 7000 I Carlisle, PA 17013 ± Fax: 717-245-7053 www.carlislesyntee.com 01,20.14�b 2014 Caritslo. Cadlsle and Surr.-Flat are trademarks of Carlisle REPRINT CODE:605536-"Sure-FIeX PVC Walkway Rolls Product Data Sheol" LFED is a registered trademark of the U_5.Green RuMing Cmincd CITY OF ARLINGTON 1 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:20200 71st Avenue NE Permit#:2121 Parcel#:00769800000300 Valuation: 168429.00 OWNER APPLICANT CONTRACTOR Name:RHINO VENTURES Name:Sound Roof Services Name:Sound Roof Services,Inc. Address:20100 71 ST AVE NE Address:18908 Hwy 99 Address: 19808 Hwy 99,Suite B City,State Zip:ARLINGTON,WA 98223-7447 City,State Zip:Lynnwood,WA 98036 City,State Zip:Lynnwood,WA 98036 Phone: Phone:425-672-4730 Phone:425-672-4730 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Re-Roof CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form an coded City f Arlington#3101.eliLi i -I Signalfre Print Name Date Released By D to CONDITIONS Call for Inspections. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 9/5/2018 Processing/Technology Fee $25.00 9/5/2018 Re-Roof $1,996.95 Total Due: $2,021.95 Total Payment: $0.00 Balance Due: $2,021.95 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon l� CITY OF ARLINGTON ' 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:20200 71st Avenue NE Permit#:2121 Parcel#:00769800000300 Valuation: 168429.00 OWNER APPLICANT CONTRACTOR Name:RHINO VENTURES Name:Sound Roof Services Name:Sound Roof Services,Inc. Address:20100 71 ST AVE NE Address:]8908 Hwy 99 Address: 19808 Hwy 99,Suite B City,State Zip:ARLINGTON,WA 98223-7447 City,State Zip:Lynnwood,WA 98036 City,State Zip:Lynnwood,WA 98036 Phone: Phone:425-672-4730 Phone:425-672-4730 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Re-Roof CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES"TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Released By Dale CONDITIONS Call for Inspections. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 9/5/2018 Processing/Technology Fee $25.00 9/5/2018 Re-Roof $1,996.95 Total Due: $2,021.95 Total Payment: $0.00 Balance Due: $2,021.95 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 2121 Permit Date: 08/27/18 Permit Type: COMMERCIAL RE-ROOF Project Name: AMT Applicant Name: Sound Roof Services Applicant Address: 18908 Hwy 99 Applicant, City, State, Zip: Lynnwood, WA 98036 Contact: Brian Storey Phone: 425-672-4730 Email: brian@soundroofservices.com Scope of Work: Commercial re-roof with partial tear-off Valuation: 168429.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 09/06/2018 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00769800000300 20200 71 STAVE NE RHINO VENTURES 637 Warehousing& Storage Services Contractors Contractor Primary Contact Phone Address Contractor Type License License# Sound Roof Services, 19808 Hwy 99, CONSTRUCTION Labor and SOUNDRS932J3 Inc Brian Storey 425-672-4730 Suite B CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status R20.ACCESSORY No inspections called in for 11/12/2019 STRUCTURE this project was complete at Completed FINAL site visit Plan Reviews Date Review Type Description Assigned To Review Status 08/27/2018 RESIDENTIAL RE-ROOF BUILDING Fees Fee Description Notes Amount Processing/Technology $25.00 Re-Roof Residential Residential $1,996.95 Total $2,021.95 Attached Letters Date Letter Description 09/05/2018 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 09/06/2018 Sound Roof Services check#10753 Launa Black $2,021.95 Outstanding Balance $0.00 Uploaded Files Date File Name 09/06/2018 3906669-2121 Issued Permit.pdf 08/27/2018 3869341-2121 Application and Specs.pdf