Loading...
HomeMy WebLinkAbout19417 45TH DR NE_BLD2183_2026 �'_Goodman GMEC96 Air Conditioning& Heating HEATING INPUT. 30,000-120,000 BTU/H Two-STAGE, MULTI-SPEED ECM GAS FURNACE UP To 9016 AFUE _ Contents Nomenclature........................................2 Product Specifications...........................3 Dimensions............................................4 Airflow Specifications............................6 Wiring Diagrams..................................10 ... Accessories..........................................12 Standard Features Cabinet Features • Energy-efficient, multi-speed ECM blower motor • Designed for multi-position installation— • Heavy-duty,aluminized-steel tubular heat exchanger upflow, horizontal left or right • Stainless-steel secondary heat exchanger • Certified for direct vent(2-pipe) • Two-stage gas valve provides quiet,economical heating or on-direct vent(1-pipe) • Durable Silicon Nitride igniter • Easy-to-install top venting with optional side venting • Quiet two-speed induced draft blower • Convenient left or right connection • Self-diagnostic control board with constant for gas and electrical service memory fault code history output to a LED • Cabinet air leakage(QLeak)<_2% • Color-coded low-voltage terminals with provisions • Heavy-gauge steel cabinet with durable finish for electronic air cleaner and humidifier • Fully insulated heat exchanger and blower section • Low continuous fan speed options offer quiet air circulation • Airtight solid bottom or side return with easy-cut tabs • All models comply with California 40 ng/J for effortless removal in bottom air-inlet applications Low NOx emissions standard • AHRI Certified; ETL Listed ENERGY STAR®and the ENERGYSTAR mark are registered trademarks owned by thecaret third -party Protection Agency.ENERGY STAR � products are third-party certified byan EPA-recognized Certification Body. Products that earn the ENERGY STAR prevent greenhouse gas emissions by meeting strict energy efficiency guidelines set by the U.S.Environmental Protection Agency. LIFETIME 10 UNIT 10 PARTS ETA REPLACEMENT C V HEAT EXCHANGER LIMITED LIMITED c us 1509001 l LIMITED WARRANTY' YEAR WARRANTY' YEAR WARRANTY' Intertek f, * Complete warranty details available from your local dealer or at www.goodmanmfg.com.To receive the Lifetime Heat Exchanger Limited Warranty BBB' (good for as long as you own your home),10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty,online registration must be completed within 60 days of installation.Online registration is not required in California or Quebec. SS-GMEC96 www.goodmanmfg.com 7/16 Supersedes 8/15 NOMENCLATURE G M E C 96 060 3 B N A A 1 2 3 4 5,6 7,8,9 10 11 12 13 14 Brand I I Minor Revision G Goodman®Brand A-Initial Release B-1st Revision Configuration M Upflow/Horizontal Major Revision C Downflow/Horizontal A-Initial Release B-1st Revision Motor V Variable Speed ECM/ComfortNet NOx E Multi-Speed ECM N-Low NOx S Single Speed Cabinet Width Gas Valve B-17.5" M Modulating C-21" C Two Stage D-24.5" S Single Stage Maximum CFM AFUE 2- 800 CFM 92 92%AFUE 3-1200 CFM 96 96%AFUE 4-1600 CFM 97 97-98%AFUE 5-2000 CFM M BTU/h 040-40,000 BTU/h 080-80,000 BTU/h 120-120,000 BTU/h 060-60,000 BTU/h 100-100,000 BTU/h 2 www.goodmanmfg.com SS-GMEC96 PRODUCT SPECIFICATIONS HEATING DATA High Fire Input' 30,000 40,000 60,000 80,000 80,000 100,000 100,000 120,000 High Fire Output' 28,800 38,400 57,600 76,800 76,800 96,000 96,000 115,200 Low-Fire Input' 21,000 28,000 42,000 S6,000 56,000 70,000 70,000 84,000 Low-Fire Output' 20,160 26,880 40,320 53,760 53,760 67,200 67,200 80,640 AFUE2 96 96 96 96 96 96 96 96 Temp.Rise Range(7) 20-50 20-50 20-50 35-65 25-55 35-65 35-65 35-65 Vent Diameter' 2"-3" 2"-3" 2"-3" 2"-3" 2"-3" 2"-3" 2"-3" 2"-3" No.of Burners 2 2 3 4 4 5 5 6 CIRCULATOR BLOWER Available AC@0.5"ESP 1.5-2 1.5-3 1.5-3 1.5-3 2.5-4 1.5-4 3-5 3-5 Size (D x W) 10"x 8" 10"x 8" 11"x 8" 11"x 8" 11"x 10" 11"x 10" 11"x 10" 11"x 11" Horsepower @ 107S RPM 1/2 1/2 1/2 1/2 3/4 1 1 1 Speed 5 5 5 5 5 5 5 5 ELECTRICAL DATA Min.CircuitAmpacity° 8 8 8 8 11.6 13.3 13.3 13.3 Max.Overcurrent(amps)$ 15 15 15 15 15 15 15 15 SHIPPING WEIGHT(LBS) 111 112 115 118 123 140 140 154 Natural Gas BTU/h 2 DOE AFUE based upon Isolated Combustion System(ICS) s Installer must supply one or two PVC pipes:one for combustion air(optional)and one for the flue outlet(required).Vent pipe must be either 2"or 3"in diameter,depending upon furnace input,number of elbows,length of run and installation(1 or 2 pipes).The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2"or 3"diameter PVC. 4 Minimum Circuit Ampacity=(1.25 x Circulator Blower Amps)+ID Blower amps.Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sizes. 5 Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size.May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 115 VAC,60 Hz,single-phase electrical supply. • Gas Service Connection''/:"FPT • Important:Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. • For bottom return:Failure to unfold flanges may reduce airflow by up to 18%.This could result in performance and noise issues. • For servicing or cleaning,a 24"front clearance is required.Unit connections(electrical,flue and drain)may necessitate greater clearances than the minimum clearances listed above.In all cases,accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. SS-GMEC96 www.goodmanmfg.com 3 DIMENSIONS J�SAir Air DIcharge Discharge 28'% A 6F Dim B % 2 Discharge 6Y Air Intake 2"Pipe 2� C 13' 19y/ 2 2 Left-Side enter Dimple Vent/Flue Pipe For Alternate 2"PVC Alternate Drain Trap Air Intake Pipe Vent/Flue Exterior Holes 3"OD Hole I Location High-Voltage Right-Side Electrical Outlet Drain Trap 0 Exterior Holes 0 Standard 0 High-Voltage Gas Supply Electrical Outlet Location Alternate Gas Supply 0 34% O 0 31% 26% 24% 23 23 19% 21 19% 14 Side Cut-out Side Cut-Out 9Y. 5 5 1'/: LEFTSIDE VIEW 1% FRONT VIEW RIGHT SIDE VIEW Low-voltage 2% Low-Voltage 2% Electrical Outlet 2% D Electrical Outlet 2Y. 1% Flanges Folded Condensate Drain 22 23 0 Trap Exterior E Folded Flanges Connection Unfolded Flanges (Right or Left Side) 23Y� %PVC Unfolded Flanges MODEL GMEC960302BNA 17%2" 16" 133/s" 12%s" 13%" GMEC960402BNA 17%2" 16" 133/s" 12%s" 13%" GMEC960603BNA 17%2" 16" 133/s" 12%s" 13%" GMEC960803BNA 17%2" 16" 133/s" 12%s" 13%" GMEC960804CNA 21" 19%2" 17%" 16" 17Y22" GMEC961004CNA 21" 19%2" 17%" 16" 17Y22" GMEC961004CNA 21" 19%2" 17%" 16" 17Y22" GMEC961205DNA 24% 23" 20%s" 19%" 20%8' MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS POSITION SIDES REAR FRONT BOTTOM .• Upflow 0" 0" 3" C 0" 1" Horizontal 6" 0" 3" C 0" 6" C=If placed on combustible floor,the floor MUST be wood ONLY. 4 www.goodmanmfg.com SS-GMEC96 AIRFLOW DATA - GMEC960302BN COOLING DIPSWITCH SETTING: 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 STATIC SWITCH BANK 2 CFM CFM Cl Cl Cl CFM CFM CFM SWITCH 12 3 G 870 658 548 469 413 349 293 N/A Ylo 874 697 612 533 470 414 361 303 **OFF OFF OFF Y 1146 1097 1049 1002 941 895 846 787 Ylo 874 697 612 533 470 414 361 303 ON OFF OFF Y 928 868 810 743 670 614 560 505 Ylo 928 868 810 743 670 614 560 505 ON ON OFF Y 1146 1097 1049 1002 941 895 846 787 Ylo 874 697 612 533 470 414 361 303 OFF ON ON Y 1146 1097 1049 1002 941 895 846 787 Ylo 885 821 755 684 621 557 508 461 ON OFF ON Y 1146 1097 1049 1002 941 895 846 787 Ylo 885 821 755 684 621 557 508 461 ON ON ON Y 874 697 612 533 470 414 361 303 ** Factory Default HEATING DIPSWITCH SETTING: 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 SWITCH BANK 3 STATIC SWITCH 12 CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM W1 870 21 658 28 548 34 469 40 413 45 349 293 N/A **OFF OFF W2 885 30 821 32 755 35 684 39 621 43 557 508 461 W1 874 21 697 27 612 31 533 35 470 40 414 361 303 ON OFF W2 885 30 821 32 755 35 684 39 621 43 557 508 461 W1 874 21 697 27 612 31 533 35 470 40 414 361 303 ON ON W2 928 29 868 31 810 33 743 36 670 40 614 560 505 W1 928 20 868 22 810 23 743 25 670 28 614 560 505 OFF ON W2 1146 23 1097 24 1049 25 11002 27 1941 28 895 846 787 ** Factory Default NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. MINIMUM FILTER SIZES 0402BNA 0603B 0803BNA 1004CNA Filter Size(in2)(Qty) 1 7(1)16 x 25(side or bottom) (1)20 x 25(bottom) or(2)16 x 25(side) Note:Other size filters of equal or greater dimensions may be used.Filters may also be centrally located. SS-GMEC96 www.goodmanmfg.com 5 AIRFLOW DATA — GMEC960402BN COOLING 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 DIPSWITCH SETTING: STATIC SWITCH BANK 2 CFM CFM CFM CFM CFM CFM CFM CFM SWITCH 12 3 G 847 694 611 535 471 415 357 313 YIo 856 667 546 466 413 357 302 N/A **OFF OFF OFF Y 1143 1095 1046 996 946 890 834 778 YIo 856 667 546 466 413 357 302 N/A ON OFF OFF Y 960 898 840 780 711 659 596 547 YIo 960 898 840 780 711 659 596 547 ON ON OFF Y 1143 1095 1046 996 946 890 834 778 YIo 960 898 840 780 711 659 596 547 OFF OFF ON Y 989 932 882 819 773 695 650 586 YIo 856 667 546 466 413 357 302 N/A OFF ON ON Y 1143 1095 1046 996 946 890 834 778 YIo 989 932 882 819 773 695 650 586 ON OFF ON Y 1143 1095 1046 996 946 890 834 778 ** Factory Default HEATING DIPSWITCH SETTING: 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 SWITCH BANK 3 STATIC SWITCH 12 CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM W1 847 29 694 36 611 41 535 47 471 53 415 357 313 **OFF OFF W2 989 36 932 38 882 40 819 43 773 46 695 650 586 W1 856 29 667 37 546 46 466 53 413 N/A 357 302 N/A ON OFF W2 989 36 932 38 882 40 819 43 773 46 695 650 586 W1 856 29 667 37 546 46 466 53 413 N/A 357 302 N/A ON ON W2 960 37 898 40 840 42 780 46 711 50 659 596 547 W1 960 26 898 28 840 30 780 32 711 35 659 596 547 OFF ON W2 1143 31 1095 32 1046 34 996 36 946 38 890 834 778 ** Factory Default NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 6 www.goodmanmfg.com SS-GMEC96 AIRFLOW DATA — GMEC960603BN COOLING 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 DIPSWITCH SETTING: STATIC SWITCH BANK 2 CFM CFM CFM CFM CFM CFM CFM CFM SWITCH 12 3 G 894 846 780 720 660 603 554 505 Ylo 782 629 547 469 396 333 N/A N/A **OFF OFF OFF Y 1236 1189 1149 1101 1066 1017 969 928 Ylo 782 629 547 469 396 333 N/A N/A ON OFF OFF Y 1149 1104 1057 1017 963 918 865 822 Ylo 1149 1104 1057 1017 963 918 865 822 ON ON OFF Y 1236 1189 1149 1101 1066 1017 969 928 Ylo 1149 1104 1057 1017 963 918 865 822 OFF OFF ON Y 1328 1287 1249 1215 1170 1131 1085 1046 Ylo 782 629 547 469 396 333 N/A N/A OFF ON ON Y 1236 1189 1149 1101 1066 1017 969 928 ** Factory Default HEATING DIPSWITCH SETTING: 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 SWITCH BANK 3 STATIC SWITCH 12 CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM W1 894 41 846 44 780 47 720 51 660 56 603 554 505 **OFF OFF W2 1328 40 1287 41 1249 42 1215 43 1170 45 1131 1085 1046 W1 782 47 629 59 547 N/A 469 N/A 396 N/A N/A N/A N/A ON OFF W2 1328 40 1287 41 1249 42 1215 43 1170 45 1131 1085 1046 W1 782 47 629 59 547 N/A 469 N/A 396 N/A N/A N/A N/A ON ON W2 1149 46 1104 48 1057 50 1017 52 963 55 918 86S 822 W1 1149 32 1104 33 1057 35 1017 36 963 38 918 86S 822 OFF ON W2 1236 43 1189 144 1149 146 11101 148 11066 50 1017 969 928 ** Factory Default NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. SS-GMEC96 www.goodmanmfg.com 7 AIRFLOW DATA — GMEC960803BN COOLING 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 DIPSWITCH SETTING: STATIC SWITCH BANK 2 CFM CFM CFM CFM CFM CFM CFM CFM SWITCH 12 3 G 1221 1172 1128 1087 1049 1005 959 922 Ylo 750 644 569 507 442 388 328 N/A **OFF OFF OFF Y 1111 1068 1025 984 941 885 N/A 801 Ylo 750 644 569 507 442 388 328 N/A ON OFF OFF Y 894 842 784 726 682 618 562 519 Ylo 894 842 784 726 682 618 562 519 ON ON OFF Y 1111 1068 1025 984 941 885 N/A 801 Ylo 894 842 784 726 682 618 562 519 OFF ON OFF Y 1221 1172 1128 1087 1049 1005 959 922 Ylo 894 842 784 726 682 618 562 519 OFF OFF ON Y 1311 1293 1249 1203 1172 1122 1088 1041 Ylo 750 644 569 507 442 388 328 N/A OFF ON ON Y 1111 1068 1025 984 941 885 N/A 801 ** Factory Default HEATING DIPSWITCH SETTING: 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 SWITCH BANK 3 STATIC SWITCH 12 CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM W1 1221 40 1172 42 1128 44 1087 45 1049 47 1005 959 922 **OFF OFF W2 1311 54 1293 54 1249 56 1203 58 1172 60 1122 1088 1041 W1 750 66 644 N/A 569 N/A 507 N/A 442 N/A 388 328 N/A ON OFF* W2 1311 54 1293 54 1249 56 1203 58 1172 60 1122 1088 1041 W1 750 66 644 N/A 569 N/A 507 N/A 442 N/A 388 328 N/A ON ON* W2 894 N/A 842 N/A 784 N/A 726 N/A 682 N/A 618 562 519 W1 894 55 842 59 784 63 726 68 682 N/A 618 562 519 OFF ON W2 11111 63 1068 66 1025 69 1 984 172 1941 75 1 885 N/A 801 * NOTRECOMMENDED ** Factory Default NOTES • All furnaces ship as high speed for cooling.Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 8 www.goodmanmfg.com SS-GMEC96 AIRFLOW DATA — GMEC960804CN COOLING 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 DIPSWITCH SETTING: STATIC SWITCH BANK 2 CFM CFM CFM CFM CFM CFM CFM CFM SWITCH 12 3 G 1281 1220 1152 1096 1031 978 914 856 Ylo 1408 1337 1279 1218 1167 1112 1062 999 **OFF OFF OFF Y 1727 1691 1642 1600 1545 1504 1449 1410 Ylo 1185 1121 1058 992 933 868 808 750 ON ON OFF Y 1727 1691 1642 1600 1545 1504 1449 1410 Ylo 1185 1121 1058 992 933 868 808 750 OFF ON OFF Y 1281 1220 1152 1096 1031 978 914 856 Ylo 1185 1121 1058 992 933 868 808 750 OFF OFF ON Y 1839 1790 1757 1699 1665 1615 1568 1527 Ylo 1408 1337 1279 1218 1167 1112 1062 999 OFF ON ON Y 1727 1691 1642 1600 1545 1504 1449 1410 ** Factory Default HEATING DIPSWITCH SETTING: 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 SWITCH BANK 3 STATIC SWITCH 12 CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM W1 1281 38 1220 40 1152 43 1096 45 1031 48 978 914 856 **OFF OFF W2 1839 38 1790 39 1757 40 1699 41 1665 42 1615 1568 1527 W1 1408 35 1337 37 1279 39 1218 40 1167 42 1112 1062 999 ON OFF W2 1839 38 1790 39 1757 40 1699 41 1665 42 1615 1568 1527 W1 1408 35 1337 37 1279 39 1218 40 1167 42 1112 1062 999 ON ON* W2 1185 N/A 1121 N/A 1058 N/A 992 N/A 933 N/A 868 808 750 W1 1185 42 1121 44 1058 47 992 50 933 53 868 808 519 OFF ON W2 1727 41 11691 42 1642 43 1600 44 1545 46 1504 1449 1410 * NOTRECOMMENDED ** Factory Default NOTES • All furnaces ship as high speed for cooling.Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. SS-GMEC96 www.goodmanmfg.com 9 AIRFLOW DATA — GMEC961004CN COOLING 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 DIPSWITCH SETTING: STATIC SWITCH BANK 2 CFM CFM CFM CFM CFM CFM CFM CFM SWITCH 12 3 G 1522 1464 1402 1338 1280 1230 1167 1101 Ylo 1004 890 805 710 620 553 474 406 **OFF OFF OFF Y 1772 1713 1662 1609 1540 1498 1452 1399 Ylo 1004 890 805 710 620 553 474 406 ON OFF OFF Y 1312 1235 1170 1101 1037 962 880 820 Ylo 1312 1235 1170 1101 1037 962 880 820 ON ON OFF Y 1772 1713 1662 1609 1540 1498 1452 1399 Ylo 1312 1235 1170 1101 1037 962 880 820 OFF ON OFF Y 1522 1464 1402 1338 1280 1230 1167 1101 Ylo 1312 1235 1170 1101 1037 962 880 820 OFF OFF ON Y 1861 1803 1749 1698 1653 1594 1549 1504 Ylo 1004 890 805 710 620 553 474 406 OFF ON ON Y 1772 1713 1662 1609 1540 1498 1452 1399 ** Factory Default HEATING DIPSWITCH SETTING: 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 SWITCH BANK 3 STATIC SWITCH 12 CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM W1 1522 40 1464 42 1402 44 1338 46 1280 48 1230 1167 1101 **OFF OFF W2 1861 47 1803 49 1749 50 1698 52 1653 53 1594 1549 1504 W1 1004 61 890 69 805 N/A 710 N/A 620 N/A 553 474 406 ON OFF W2 1861 47 1803 49 1749 50 1698 52 1653 53 1594 1549 1504 W1 1004 61 890 69 805 N/A 710 N/A 620 N/A 553 474 406 ON ON* W2 1312 67 1235 N/A 1170 N/A 1101 N/A 1037 N/A 962 880 820 W1 1312 47 1235 50 1170 53 1101 56 1037 59 962 880 820 OFF ON W2 1772 150 1713 51 1662 153 1609 1 55 1540 1 57 1498 1452 1399 * NOTRECOMMENDED ** Factory Default NOTES • All furnaces ship as high speed for cooling.Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 10 www.goodmanmfg.com SS-GMEC96 AIRFLOW DATA — GMEC961005CN COOLING 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 DIPSWITCH SETTING: STATIC SWITCH BANK 2 CFM CFM CFM CFM CFM CFM CFM CFM SWITCH 12 3 G 1283 1219 1162 1101 1036 974 917 864 Y10 1438 1366 1309 1254 1163 1133 1077 1013 **OFF OFF OFF Y 2008 1963 1964 1916 1876 1839 1801 1759 Y10 1384 1324 1271 1204 1145 1088 1029 985 ON ON OFF Y 2008 1963 1964 1916 1876 1839 1801 1759 Y10 1384 1324 1271 1204 1145 1088 1029 985 OFF OFF ON Y 1811 1772 1733 1690 1644 1590 1551 1492 Y10 1438 1366 1309 1254 1163 1133 1077 1013 OFF ON ON Y 2008 1963 1964 1916 1876 1839 1801 1759 Y10 1811 1772 1733 1690 1644 1590 1551 1492 ON OFF ON Y 2008 1963 1964 1916 1876 1839 1801 1759 ** Factory Default HEATING DIPSWITCH SETTING: 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 SWITCH BANK 3 STATIC SWITCH 12 CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM W1 1283 48 1219 51 1162 53 1101 56 1036 59 974 917 864 **OFF OFF W2 1811 49 1772 50 1733 51 1690 52 1644 54 1590 1551 1492 W1 1438 43 1366 45 1309 47 1254 49 1163 53 1133 1077 1013 ON OFF W2 1811 49 1772 50 1733 51 1690 52 1644 54 1590 1551 1492 W1 1438 43 1366 45 1309 47 1254 49 1163 53 1133 1077 1013 ON ON* W2 1384 64 1324 N/A 1271 N/A 1204 N/A 1145 N/A 1088 1029 985 W1 1384 44 1324 47 1271 48 1204 51 1145 54 1088 1029 985 OFF ON W2 2008 44 1963 45 1964 45 1 1916 46 1876 47 11839 1801 1759 * NOTRECOMMENDED ** Factory Default NOTES • All furnaces ship as high speed for cooling.Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. SS-GMEC96 www.goodmanmfg.com 11 AIRFLOW DATA — GMEC961205DN COOLING 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 DIPSWITCH SETTING: STATIC SWITCH BANK 2 CFM CFM CFM CFM CFM CFM CFM CFM SWITCH 12 3 G 1796 1753 1697 1645 1589 1536 1478 1425 Ylo 1106 1017 946 855 764 681 605 N/A **OFF OFF OFF Y 1683 1628 1565 1511 1445 1387 1340 1276 Ylo 1106 1017 946 855 764 681 605 N/A ON OFF OFF Y 1399 1327 1259 1185 1118 1051 980 913 Ylo 1399 1327 1259 1185 1118 1051 980 913 ON ON OFF Y 1683 1628 1565 1511 1445 1387 1340 1276 Ylo 1399 1327 1259 1185 1118 1051 980 913 OFF ON OFF Y 1796 1753 1697 1645 1589 1536 1478 1425 Ylo 1399 1327 1259 1185 1118 1051 980 913 OFF OFF ON Y 2211 2162 2122 2076 2029 1986 1984 1942 Ylo 1106 1017 946 855 764 681 605 N/A OFF ON ON Y 1683 1628 1565 1511 1445 1387 1340 1276 ** Factory Default HEATING DIPSWITCH SETTING: 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 SWITCH BANK 3 STATIC SWITCH 12 CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM W1 1796 41 1753 42 1697 44 1645 45 1589 47 1536 1478 1425 **OFF OFF W2 2211 48 2162 49 2122 50 2076 51 2029 52 1986 1984 1942 W1 1106 67 1017 73 946 N/A 855 N/A 764 N/A 681 605 N/A ON OFF W2 2211 48 2162 49 2122 50 2076 51 2029 52 1986 1984 1942 W1 1106 67 1017 73 946 N/A 855 N/A 764 N/A 681 605 N/A ON ON* W2 1399 75 1327 N/A 1259 N/A 1185 N/A 1118 N/A 1051 980 913 W1 1399 53 1327 56 1259 59 1185 62 1118 66 1051 980 913 OFF ON W2 1683 163 11628 65 1565 67 1511 70 1445 73 1387 1340 1276 * NOTRECOMMENDED ** Factory Default NOTES • All furnaces ship as high speed for cooling.Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 12 www.goodmanmfg.com SS-GMEC96 TEMPERATURE RISE RANGE CHART O LO - O L - x 00 Q - N - O Q x Z3 C _ (M LL Q Q - U I O x - O - \ 2 LL Q LL - U O Z3 CO - N O t - � - D a - m iTf _ H - p� - O Q - � _ _ W V1 LL - - GC U - O O O O o O O N N - rl Q O N _ X O N - 2 W °r°V - a o - o � o w H c - > o - a H C) d 00 00 _ O F- O - O o -_ D - O H o - ti pp ao - o - o - L U - O o - O cn - - O LO NA\ - O L_j 1 11 1 1 1 11 1 1 11 1 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1\1� I I — III O O O M O O O O O O O O 00 1` co LO M N isw 3bjnivd3dW31 SS-GMEC96 www.goodmanmfg.com 13 WIRING DIAGRAM — GMEC96******AA 0 r� --III GND TO C 115 VAC/1 0/60 HZ r 1 POWER SUPPLY WITH ID BLOWER TWO STAGE PRESSURE ti OVERCURRENT HOT SWITCH ASSEMBLY < Z V L PROTECTION DEVICE O SURFACE C { IGNITER OR HIGH FIRE O K r 1 WARN ING:DISCON NECT PRESSURE 4 POWER BEFORE 9 LOW FIRE p p SWITCH 1 —N SERVICING.WIRING PRESSURE Np N O W TO UNIT MUST BE SWITCH DISCONNECT PROPERLY POLARIZED 2 CIRCUIT AND GROUNDED. CONNECTOR OR TO 115VAC/10/60 HZ POWER SUPPLY WITH �0 Hr PU OVERCURRENT PROTECTION DEVICE 0 FLAME L GND N CY GY SENSOR WARNING:TWO STAGE DISCONNECT POWER GAS VALVE PM FRONT COVER BEFORE SERVICING. T I (WHITE RODGERS) PRESSURE SWITCH WIRING TO UNIT MUST BE PROPERLY v MANUAL RESET ROLLOUT LIMIT POLARIZED AND GROUNDED. DISCONNECT O N CONTROLS(SINGLE CONTROL ON 30 kBTU AND 40 kBTU) N O BL PK OR rI "� DOOR SWITCH AUTO RESET PRIMARY ani JUNCTION BOX LIMIT CONTROL PU Y O E O G D INDUCED �y� IN DOROF Q WH DRAFT I c CIRCULATOR ,�., 2 RD LBLOWER Z BLWR N� BK C GND BURNER COMPARTMENT GND LINE O NEUTRAL H -p BLOWER COMPARTMENT PU Y N AUTO RESET -Q\-��"F/� / T�-/\gyp UM-OUT O p- T. AUXILIARY V/ YL V/ K �UMIDIFI�R NEUTRAL b0 O LIMITCONTROL HUM C !Z z ELECTRONIC NEUTRAL AlR CLEANER i ti p IND HI N NEUTRAL Q D O BLWR O N ND LO NEUTRAL E HOT SURFACE IGNITER O 0! -O BK 3 BLOR RD BK w `L s o LAME F SENSOR O Q N LINE 115 VAC NEUTRAL TLINE 1rJg 0 U 3 ti NEUTRAL SE 3 A 40 VA FU ++ s y <G B TH 5 TRANSFORMER li 24 VAC AUTO RESET PRIMARY O W TO O v I LIMIT CONTROL N O n Y1 EL -DC IHLO 11 ✓pi N AUTO RESET AUXILIARY LIMIT pj O O I CONTROLS p tea O D D W1 PS1(12) C NO S1� �OO g WZ I PS2(2) NO SWITCHE PRESS V2 I HIGH FIRE O MI = ON S2R R PRESS..—I., MANUAL RESET ROLLOUT LIMIT CONTROLS I GV BR � O HLI 6) fl G DIAGNOSTIC FHUM YL ' O Si I MVL(]) PM O LED'S VL PK I �MVH(1) D BR m C MVC(8) NO Q HI OR F GND(4) C FRONT COVER GAS 5 VLO V W1 W2 R G C TWIN PRESSURE VALVE N.E.C.CLASS 2 WIRE 24 V 3 A TR(9) GND SWITCH Q FUSE Q TO ® n A n N R a ECM MTR G) IP R OR HARNESS II H TO ICAOROR CIRCULATOR FITO MICRO BLWR GND > y q W H y'o 6 L C 3 BK �� BK INTEGRATED CONTROL MODULE 3 C Y 2 G� O ?i 1 O Z B NOTES: N E 1.SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT AMPS. � D 2.MANUFACTURER MUST SPECIFIED REPLACEMENT PARTS MUST BE USED C 12 'O `2 9 WHEN OF THEIORI = BLOWER 3.IF MUST BE REPLACED IT M ST BEIRE REPLASUPPLCED WITH THE FURNACE L CIRCULATOR BLOWER COMPARTMENT MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATERIAL p d DOOR SWITCH HAVING A TEMPERATURE RATING OF AT LEAST 108M.USE COPPER y0 h9 (OPEN WHEN CONDUCTORS ONLY. C ++ DOOR OPEN) 4,UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. NO AND LOCAL CODES. 5.TO RECALL THE LAST 8 FAULTS,MOST RECENT TO LEAST RECENT, 3 E RED LED FLASH CODE DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY H L N STEADY ON=INTERNAL GV ERROR,MICRO AND FREQUENCY CHECK AMBER LED FLASH CODE NO THERMOSTAT INPUTS y y COLOR CODES: EQUIPMENT GND /fib O RAPID =TWINNING ERROR RAPID =LOW FLAME SENSE CURRENT m+'0 1 FLASH =FLAME SENSED WHEN NO FLAME SHOULD BE PRESENT 1 FLASH=NORMAL OPERATION WITH CALL FOR PK PINK FIELD GND w ++ 1STSTAGEHEAT(WD BR BROWN FIELD SPLICE v j 2 FLAB HES=PRESSURE SWITCH STUCK CLOSED/INDUCER ERROR �2 FLASHES=NORMAL OPERATION WITH WH WHITE 3 FLASHES=1ST STAGE PRESSURE SWITCH STUCK CALL FOR 2ND STAGE HEAT BL BLUE SWITCH(TEMP.) 6 CLOSED/INDUCER ERROR 3 FLASHES=W2 PRESENT WITH NO Wt GY GRAY IGNITER ZFI-FLI 4 FLASHES=OPEN LIMIT SWITCH RD RED 4 FLASHES=V PRESENT WITH NO G CALL,VLO VL YELLOW SW ITCH(PRESS.) 5 FLASHES=OPEN ROLLOUT/OPEN FUSE DETECTED PRESENT WITH NO G CALL OR ORANGE OVERCURRENT 6 FLASHES=PRESSURE SWITCH CYCLE LOCKOUT GREEN LED FLASH CODE PU PURPLE PROT.DEVICE ]FLASHES=EXTERNAL LOCKOUT(RETRIES) GINGREEN ,JUNCTION STEADY ON=STANDBY BK BLACK e FLASHES=EXTERNAL LOCKOUT(RECYCLES) RAPID=NORMAL OPERATION WITH CALL FOR FAN(G) TERMINAL B FLASHES+GROUNDING OR REVERSED POLARITY INTERNAL 1 FLASH=NORMAL OPERATION WITH CALL FOR INTEGRATED CONTROL 10 FLASHES=GAS FLOW WITH NO CALL FOR HEAT LOW STAGE COOL(VLO+G) � 7 11 FLASHES=LIMIT SWITCH OPEN-BLOWER FAILURE *2 FLASHES=NORMAL OPERATION WITH CALL FOR HIGH r' I PLUG CONNECTION STAGE COOV OR SINGLE STAGE COOLING(V+G) y+ LOW VOLTAGE(24V) 12 FLASHES=IGNITOR RELAY FAILURE LOW VOLTAGE FIELD — 3 DOUBLE FLASHES=2ND STAGE PRESSURE SWITCH HI VOLTAGE(115V) STUCK OPEN/INDUCER ERROR 0140F02011-A HI VOLTAGE FIELD 14 www.goodmanmfg.com SS-GMEC96 WIRING DIAGRAM —GMEC96******AB 0 r� GND 1 5 VAC/10/60 HZ r POWER SUPPLY WITH ID BLOWER TWO-STAGE PRESSURE z L, OVERCURRENT HOT SWITCH ASSEMBLY j J� L PROTECTION DEVICE 11_ V j A IGNITER OR HIGH FIREr 0 K r WARNING:DISCONNECT PRESSURE 4 % POWER BEFORE z LOW FIRE c SWITCH 1 �N SERVICING.WIRING W TO UNIT MUST BE PRESSURE PROPERLY POLARIZED 2 CIRCUIT SWITCH NO N DISCONNECT AND GROUNDED. CONNECTOR OR TO 115VAC/10/60 HZ POWER SUPPLY WITH HI 3 U P OVERCURRENT PROTECTION DEVICE GND FLAME WARNING: $ I TWO STAGE C 2 GY GY SENSOR DISCONNECT POWER T GAS VALVE PM 1 BR FRONTCOVER BEF I N. ORE SERVICING. (WHITE RODGERS) PRESSURE SWITCH W IRING TO UNIT MUST BE PROPERLY POLARIZED AND w z MANUAL RESET ROLLOUT LIMIT GROUNDED. DISCONNECt o CONTROLS(SINGLE CONTROL ON O--O 30 kBTU AND 40 kBTU) N o OR I O BL pK m DOOR 'T rf � O SWITCH L J L J L J O J AUTO RESET PRIMARY > JUNCTION Box LIMIT CONTROL PU u1 N C O 0 GND C INDUCED A INDOOR FFr: 3 WH DRAFT C CIRCUILATOR I N 2 RD BLOWER Z p BLWR N BK oC0 GND BURNER COMPARTMENT GND LINE C4SENSOR NEUTRAL m �'o BLOWER COMPARTMENT pU > AUTO RESET F-Q\-���/� /\/��F\/� ,vm UTLOUTO d AUXILIARY \Y YL \- PK y FIER NEUTRAL UO O LIMIT CONTROL HUM C NIC,i NR,INNEUTRALR > INNEUTRALFACEO ERO BBK SOR O.�O O LIN x I LINE 115 VAC NEUTRAL `1 3 ti N O �� NEUTRAL FUSE 40 VA O O TRANSFORMER - = R TH 5[] li O A 24 VAC AUTO RESET PRIMARY C C O TO IaLQ LIMIT CONTROL C h Al I +VDC � r '< Y1 ===I " _ a AUTO RESET AUXILIARY LIMIT S S1 CONTROLS 171 �. 11NO r 19 �/��)��J/ PSt(12) C S3 V A W2 I LOW FIRE PRESS T. P52(2) N SWITCH = � ❑ 12 N cao O C 52 HIGH FIRE _ in O� O PRESS.SWTICH MANUAL RESET ROLLOUT LIMIT CONTROLS Z C'y BR O HLI 8 1n DIAGNOSTIC y DEHU I MVL(]) �Vr� O LED'S PU PM YL PK * I MVH(t) c BR m c wC(8) NO e O HI C FRONT COVER YLO Y W1 W2 R G C TWIN GND 4 PRESSURE GAS VALVE O N.E.C.CLAS82WIRE 24V3A ITR 9 GND SWITCH F GN G� TO a ECM MTR G) m R ORK HARNESS II H TO LL INDOOR BL O MICRO CIR LLARTOR A GND 4 W za N Y D 3 B OGD BK INTEGRATED CONTROL MODULE 3 C ,� 2 GN� Q O 3 1 O = NOTES: N 1,SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT AMPS. N GND � A 2.MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED BLOWER WHEN SERVICING. b0� 3.IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE L N y0 CIRCULATOR BLOWER COMPARTMENT MUST BE REPLACED IT MUST BE REPLACED WITH WIRI NG MATERIAL V-O DOOR SWITCH HAVING A TEMPERATURE RATING OF AT LEAST 105$C.USE COPPER O p0 a (OPEN WHEN CONDUCTORS ONLY. Y C �, DOOR OPEN) q.UNIT MUSTBE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. N '3 O 5.TO RECALL THE LAST 6 FAULTS,MOST RECENT TO LEAST RECENT, 9 E RED LED FLASH CODE DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY W Y Y STEADY ON=INTERNAL IV ERROR,MICRO AND FREQUENCYAMBER LED FLASH CODE NO THERMOSTAT INPUTS) CHECK in RAPID =TWINNING ERROR *RAPID =LOW FLAME SENSE CURRENT COLOR CODES: EQUIPMENT GND r7­71 by++ 1 FL PK PINK FIELD GNDASH =FLAME SENSED WHEN NO FLAME SHOULD BE PRESENT 1 FLASH=NORMAL OPERATION WITH CALL FOR ION BR BROWN FIELD SPLICE a/ 2 FLASHES=PRESSURE SWITCH STUCK CLOSED/INDUCER ERROR 1ST STAGE HEAT�2 2 FLASHES=NORMAL OPERATION WITH W H WHITE � C 3 FLASHES=ISTSTAGEPR ESSURE SWITCH STUCK CALL FOR 2ND STAGE HEAT BLBLUE SWITCH(TEMP.) OPEWINDUCER ERROR 3 FLASHES=W2 PRESENT WITH NO W1 GY GRAY IGNITER RD RED L T 4 FLASHES=OPEN LIMIT SWITCH 4 FLASHES=V PRESENT WITH NO G CALL,YLO YL YELLOW SWITCH(PRESS.) p- $ 5 FLASHES OPEN ROLLOUT/OPEN FUSE DETECTED PRESENT WITH NOG CALL OR ORANGE QVERQURRENT 6 FLASHES=PRESSURE SWITCH CYCLE LOCKOUT GREEN LED FLASH CODE PU PURPLE pROT.DEVICE ]FLASHES EXTERNAL LOCKOUT(RETRIES) G BK BLACK N GREEN JUNCTION AN 8 FLASHES=EXTERNAL LOCKOUT(RECYCLES) RgpID=NORMAL OPERATION WITH CALL FOR FAN(G) TERMINAL -C'8 FLASHES+GROUNDING OR REVERSED POLARITY INTERNAL TO_ TSTEADYOM= ST DBY 1 FLASH=NORMAL OPERATION WITH CALL FOR INTEGRATED CONTROL 1 10 FLASHES=GAS FLOW WITH NO CALL FOR HEAT LOW STAGE COL(YLO+G) 1 11 FLASHES=LIMIT SWITCH OPEN-BLOWER FAILURE *2 FLASHES =NORMAL OPERATION WITH CALL FOR HIGH PLUG CONNECTION STAGE COOL/OR SINGLE STAGE COOLING(Y+G) LOW VOLTAGE(24V) 1 12 FLASHES=IGNITOR RELAY FAILURE LOW VOLTAGE FIELD— 3 DOUBLE FLASHES=2ND STAGE PRESSURE SWITCH HI VOLTAGE(115V) STUCK OPEN/INDUCER ERROR 0140F02058-A HI VOLTAGE FIELD SS-GMEC96 www.goodmanmfg.com 15 ACCESSORIES MODEL CVENT-2 Concentric Vent Kit(2") V V V V V V V CVENT-3 Concentric Vent Kit(3") V V V V V V V V RF000142 Drain Kit-Horizontal Left Vertical Flue V V V V V V V V External Filter Rack with EFR02 16"x25"Permanent Filter V V V V V V V 0170KOOOOOS Flush Mount Vent Kit-3"or 2" V V V V V V V V 0170K00001S Flush Mount Vent Kit-2" V V V V V V V V AFE18-60A Fossil Fuel(Dual Fuel)Kit V V V V V V V V HASFK High-Altitude Natural Gas Kit N/A HASFK-1 HASFK-1 HASFK-2 HASFK-2 HASFK-2 HASFK-3 HASFK-3 HASFK High-Altitude LP Gas Kit N/A HASFK-1 HASFK-1 HASFK-2 HASFK-2 HASFK-2 HASFK-2 HASFK-2 LPLP03 Low LP Gas Pressure Switch V V V V V V V V LPM-08 LP Conversion Kits --- V V V V V V V LPM-30 LP Conversion Kit V --- --- --- --- --- --- --- Goodman Manufacturing Company,L.P.,reserves the right to discontinue,or change at any time,specifications or designs without notice or without incurring obligations.©2016 Goodman Manufacturing Company,L.P. • Houston,Texas 16 www.goodmanmfg.com SS-GMEC96 RESIDENTIAL MECHANICAL PERMIT APPLICATION t�N Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: 19417 45th Drive Northeast Project Description:install gas furnace Owner: Joe Recchi Address. 19417 45th Drive Northeast City. Arlington State.WA Zip Code: 98223 Phone: (425) 232-8185 Email:Jrecchi@yahoo.com Applicant: CM Heating Address: 1415 Broadway City: Everett State.wa Zip Code: 98201 Phone. 4252590550 Email: meredith@cmheating.com CONTRACTOR INFORMATION Contractor Name:cm heating Address: 1415 broadway City: everett State vva Zip Code: 98201 License Number:cmheai*095r4 Expiration. 5/19 Phone: 4252590550 Email:meredith@cmheating.com STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 Y. RESIDENTIAL MECHANICAL PERMIT APPLICATION SING Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #GMEC960402BN AFUE96% ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: [El Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Ly�ce� Applicant Signature: d5a513b"a92O "'e`1e6 Date: 09/24/2018 Applicant Printed Name: meredith gilbert I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 NOTICE II8 TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY mrAPPROVED PERMIT#: LOT#: DATE: JOB ADDRESS: TYPE OF INSPECTION: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT:AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK:MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE I1 ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THEACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BY LAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR 0AYt ����� C399!kDING DEPT. Cl PLANNING DEPT. CITY OF ARLINGTON '� - i CITY O ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:19417 45th Drive NE Permit#:2193 Parcel#:00928200007300 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:RECCHI JOSEPH P JR Name:CM Heating Name:CM Heating Inc Address: 19417 45TH DR NE Address:1415 Broadway Address: 1415 Broadway City,State Zip:ARLINGTON,WA 98223-4758 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Name: Address:1415 Broadway Address: City,Slate,Zip:Everett,WA 98201 City,Stale,Zip: Phone:425-259-0550 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE.TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1 t0/IRCI I0. SA .<S TAX NOTICE:Salcs tax relating to construction and construction materials in the City of A ingot o tst be reported on your sales tax rut m funn atul coded City Arlie pion#3101. p� 'Ib � •r (l�j Signature Print Name Dale elcascd By Vale CONDITIONS Cali for final inspection. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY, ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 9/25/2018 Mechanical Fee(Enter Fixture Fee) $25.00 9/2 512 01 8 Mechanical Permit Base Fee $25.00 912512018 Processing/Technotogy Fee $25.00 Total Due: $75,00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon i I GITY of ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 ` PHONE; (360) 403-3551 BUILDING PERMIT Address:19417 45th Drive NE Permit#:2183 Parcel#:00928200007300 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:RECCHI JOSEPH P JR Name:CM Heating Name:CM Heating Inc Address: 19417 45TH DR NE Address:1415 Broadway Address: 1415 Broadway City,State Zip:ARLINGTON,WA 98223-4758 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Name: Address: 1415 Broadway Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-259-0550 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: I OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI l0/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of At ingt( n tst be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date elcased By v oate CONDITIONS Call for final inspection. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 9/25/2018 Mechanical Fee(Enter Fixture Fee) $25.00 9/25/2018 Mechanical Permit Base Fee $25.00 9/25/2018 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon r �. RLSIDENTIAL MECHANICAL ? PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223 • Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:19417 45th Drive Northeast Project Description:install gas furnace Owner: Joe Recchi Address: 19417 45th Drive Northeast City: Arlington StateYVA Zip Code: 98223 Phone: (425) 232-8185 Email:jrecchi@yahoo.com Applicant: CM Heating Address: 1415 Broadway City: Everett Stated Zip Code: 98201 Phone: 4252590550 Email: meredith@cmheating.com CONTRACTOR INFORMATION Contractor Name:cm heating Address: 1415 broadway City: everett State.wa Zip Code: 98201 License Number:cmheai*095r4 Expiration: 5/19 Phone:4252590550 Email:meredith@cmheating.com STAFF USE ONLY Permit #: Accepted b Date: p y 6/16LP Page 1 of 2 RLSIDENTIAL MEChANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223 • Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES [� Furnace (80+) Model #GMEC960402BN AFUE96% ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert L-1; Outdoor BBQ ❑ Gas Piping a; Solid-Fuel Appliance Other Gas Piping Informatio�i Not Applicable: d Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances 95a ti.,s,ome_oaae � �t��editk•�iltle�t Applicant Signature: Date: 09/24/2018 Applicant Printed Name: meredith gilbert I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 NOTICE tA TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY 04PPROVED PERMIT#: Z LOT#: DATE: JOB ADDRESS: 1. �- � K .-5 TYPE OF INSPECTION: ! i � ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT:AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK:MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE IT. ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR ATE 1313 1LDING DEPT. O PLANNING DEPT. r > CITY OF ARLINGTON :,M1�• CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:19417 45th Drive NE Permit#:2183 Parcel#:00928200007300 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:RECCHI JOSEPH P JR Name:CM Heating Name:CM Heating Inc Address: 19417 45TH DR NE Address:1415 Broadway Address: 1415 Broadway City,State Zip:ARLINGTON,WA 98223-4758 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Namc Address: 1415 Broadway Address: City,State,Zip:Everett,WA 98201 City.State,Zip: Phone:425-259-0550 Phone: LIC#: EXP LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: I OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110, SALES TAX N01*1CF.:Saks tax relating to construction and construction materials in the City of A%ingt( hbe reported on your sales tax ren rn funn a coded City i Arlii glon#3101, '6,1,/,4Z e 'Ib i L Signatu;cl Print Name Date elcascd By atc CONDITIONS Call for final inspection. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 9/25/2018 Mechanical Fee(Enter Fixture Fee) $25.00 9/25/2018 Mechanical Permit Base Fee $25.00 9/25/2018 Process!ng/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS - BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 4P PHONE; (360) 403-3551 BUILDING PERMIT Address:19417 45th Drive NE Permit#:2183 Parcel#:00928200007300 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:RECCHI JOSEPH P JR Name:CM Heating Name:CM Heating Inc Address: 19417 45TH DR NE Address:1415 Broadway Address: 1415 Broadway City,State Zip:ARLINGTON,WA 98223-4758 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Name: Address: 1415 Broadway Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-259-0550 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: I OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC l0/IRCI10. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of ingt i st be reported on your sales tax retyrn form and coded City of Arlington#3101. Signature Print Name Date eleased By ate CONDITIONS Call for final inspection. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 9/25/2018 Mechanical Fee(Enter Fixture Fee) $25.00 9/25/2018 Mechanical Permit Base Fee $25.00 9/25/2018 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 2183 Permit Date: 09/25/18 Permit Type: RESIDENTIAL MECHANICAL Project Name: Recchi Applicant Name: CM Heating Applicant Address: 1415 Broadway Applicant, City, State, Zip: Everett,WA 98201 Contact: Meredith Gilbert Phone: 425-259-0550 Email: meredith@cmheating.com Scope of Work: Replace gas furnace Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 11/09/2018 Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Launa Black Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00928200007300 19417 45TH DR NE RECCHI JOSEPH P 111 Single Family JR Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Plumbing CMHEAHL750LP ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Construction CMHEAHL751 W ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION UBI 605890285 ST STE 200 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status C10. 11/09/2018 MECHANICAL 11/09/2018 11/09/2018 BUILDING Approved ROUGH-IN Fees Fee Description Notes Amount Mechanical Fee(Enter Fixture Fee) $25.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Total $75.00 Attached Letters Date Letter Description 09/25/2018 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 09/26/2018 debbie bauers 71920604 cc $75.00 Outstanding Balance $0.00 Notes Date Note Created By: 09/26/2018 Emailed permit for signature. Kristin Foster Uploaded Files Date File Name 11/20/2018 4210921-2183 11-9-2018Inspection Card.pdf 11/09/2018 4179983-2183 Issued Permit.pdf 09/25/2018 3976845- 19417 attachments CO15031000017664943 B3i1KR7gSj2LrkmglLx8 Goodman+GMEC96+Spec+Sheet+recchi.pdf 09/25/2018 3976846-19417 Residential Mechanical 29EOAPtCZ4jVZb.pdf