Loading...
HomeMy WebLinkAbout19215 46TH DR NE_BLD1982_2026 19 O J 'w vi 1 ID � t � Vi 01 i I 1 (J P A g CITY OF ARLINGTON 238 N. OLYMPIC AVE- ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:19215 46th Drive NE Permit#:1982 Parcel#:00928200000600 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:WILLIAMS CIIRISTOPHER M&CHERILYN C Name:Washington Energy Services Name:WASHINGTON ENERGY SERVICES Address: 19215 46TH DR NE Address:3909 196th Sheet SW Address:3909 196th Street SW City,State Zip:ARLINGTON,WA 98223-4762 City,State Zip:Lynnwood,WA 98036 City,State Zip:Lynnwood,WA 98036 Phone: Phone:206-378-6648 Phone:800-398-4663 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:WASHINGTON ENERGY SERVICES Name: Address:3909 196th Street SW Address: City,State,Zip:Lynnwood,WA 98036 City,State,Zip: Phone:800-398-4663 Phone: L1C#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: I OCC GROUP: BUILDINGS: I OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITI I CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL HE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S I COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE.AND APPROVAL OR i A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/1RC110. SALE5 TAX NOT1 :Sales tax relating to construction and construction materials in the City ofArlingtoymm I be eported on your sales tax return form and d City of Arbalwn#3101. Print Vne DaV VRel4iscd By Date ' CONDITIONS ADHERE TO APPROVED APPLIANCE. 3" CONCRETE PAD WITH SEISMIC BRACING REQUIRED. ELECTRICAL DISCONNECT REQUIRED. LINES SHALL BE INSULATED AND THE USE OF ADHESIVE TAPE IS NOT PERMITTED. CALL FOR FINAL INSPECTION. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 5/30/2018 A/C Unit $25.00 5/30/2018 Furnace $25.00 5/30/2018 Mechanical Permit Base Fee $25.00 5/30/2018 Processing/Technology Fee $25.00 Total Due: $100.00 Total Payment: $0.00 Balance Due: $100.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:19215 46th Drive NE Permit#:1982 Parcel#:00928200000600 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:WILLIAMS CHRISTOPHER M&CHERILYN C Name:Washington Energy Services Name:WASHINGTON ENERGY SERVICES Address: 19215 46TH DR NE Address:3909 196th Street SW Address:3909 196th Street SW City,State Zip:ARLINGTON,WA 98223-4762 City,State Zip:Lynnwood,WA 98036 City,State Zip:Lynnwood,WA 98036 Phone: Phone:206-378-6648 Phone:800-398-4663 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:WASHINGTON ENERGY SERVICES Name: Address:3909 196th Street SW Address: City,State,Zip:Lynnwood,WA 98036 City,State,Zip: Phone:800-398-4663 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRCI10. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington mu t be sported on your sales tax return form and coded City of Arlington#3101. '��l-&- I� Signature Print Name Date VRel scd By Date CONDITIONS ADHERE TO APPROVED APPLIANCE. 3" CONCRETE PAD WITH SEISMIC BRACING REQUIRED. ELECTRICAL DISCONNECT REQUIRED. LINES SHALL BE INSULATED AND THE USE OF ADHESIVE TAPE IS NOT PERMITTED. CALL FOR FINAL INSPECTION. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 5/30/2018 A/C Unit $25.00 5/30/2018 Furnace $25.00 5/30/2018 Mechanical Permit Base Fee $25.00 5/30/2018 Processing/Technology Fee $25.00 Total Due: $100.00 Total Payment: $0.00 Balance Due: $100.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON 238 N. OLYMPIC AVE- ARLINGTON, WA, 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:19215 46th Drive NE Permit#:1982 Parcel#:00928200000600 Valuation:0,00 OWNER APPLICANT CONTRACTOR Name:WILLIAMS CIiRISTOPHER M&CHERiLYN C Name:Washington Energy Services Name:WASHINGTON ENERGY SERVICES Address: 19215 46TII DR NE Address:3909 196th Street SW Address:3909 196th Street SW City,State Zip:ARLINGTON,WA 98223-4762 City,State Zip:Lynnwood,WA 98036 City,State Zip:Lynnwood,WA 98036 Phone: Phone:206-378-6648 Phone:800-3984663 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:WASHINGTON ENERGY SERVICES Name: Address:3909 196th Street SW Address: City,State,Zip:Lynnwood,WA 98036 City,State,Zip: Phone:800-398-4663 Phone: L1C#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL HE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL F'--NED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A B U I `IRE UNTIL A FINAL INSPECTION HAS BEEN MADF,AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN .SALES%TAX No'' rU Sales tax relating to coi ' _ 7 of Arlmgto mtl 1 he epurted on your sales tax return form and •od City of Ar IgLol1#3101. �r/ II r �r;SijnaMrc Rcl tsed By Date ADHERE TO APPROVED A_ kD WITH SEISMIC BRACING REQUIRED. ELECTRICAL DISCONNECT K_L;., ALL BE INSULATED AND THE USE OF ADHESIVE TAPE IS NOT PEKiv._ kLL FOR FINAL INSPECTION. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED,THIS PERMIT COVERS vw TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 5/30/2018 A/C Unit $25.00 5/30/2018 Furnace $25.00 5/30/2018 Mechanical Permit Base Fee $25.00 5/30/2018 Processing/Technology Fee $25.00 Total Due: S100.00 Total Payment: $0.00 Balance Due: $100.00 _CALL FOR INSPECTIONS 13UILDING(360)403-3417 When calling]or an inspection please leave the following information: Per mit Number,"Type of Inspection being requested,and whether you prefer morning;or afternoon ., I I I `\ UTY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:19215 46th Drive NE Permit#:1982 Parcel#:00928200000600 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:WILLIAMS CHRISTOPHER M& Name:Washington Energy Services Name:WASHINGTON ENERGY SERVICES CHERILYN C Address: 19215 46TH DR NE Address:3909 196th Street SW Address:3909 196th Street SW City,State Zip:ARLINGTON,WA 98223-4762 City,State Zip:Lynnwood,WA 98036 City,State Zip:Lynnwood,WA 98036 Phone: Phone:206-378-6648 Phone:800-3984663 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:WASHINGTON ENERGY SERVICES Name: Address:3909 196th Street SW Address: City,State,Zip:Lynnwood,WA 98036 City,State,Zip: Phone:800-398-4663 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: I OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlingto96�;a� tax return form and coded City of Arlington#3101. Vol; ^ Signature Print Name Date Vltel,46sed By Date CONDITIONS ADHERE TO APPROVED APPLIANCE. 3" CONCRETE PAD WITH SEISMIC BRACING REQUIRED. ELECTRICAL DISCONNECT REQUIRED. LINES SHALL BE INSULATED AND THE USE OF ADHESIVE TAPE IS NOT PERMITTED. CALL FOR FINAL INSPECTION. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 5/30/2018 A/C Unit $25.00 5/30/2018 Furnace $25.00 5/30/2018 Mechanical Permit Base Fee $25.00 5/30/2018 Processing/Technology Fee $25.00 Total Due: $100.00 Total Payment: $0.00 Balance Due: $100.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Y. ° RESIDENTIAL MECHANICAL } PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES, PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:19215 46th Dr NE Project Description:Installing furnace and heat pump. Owner: Chris Williams Address: 19215 46th Dr NE City:Arlington StateYVa Zip Code: 98223 Phone: 3606535997 Email:chris.williams@hotmail.com Applicant: Washington energy Services Address.3909 196th St SW City: Lynnwood Stated Zip Code: 98036 Phone: 2063786648 Email: NHyett-Schnell@washingtonenergy.com CONTRACTOR INFORMATION Contractor Name:Washignton energy services Address: 3909 196th St SW City: Lynnwood _ Statewa Zip Code: 98036 License Number:washies851ns i _ Expiration: 0907/19 Phone:2063786648 Email:NHyett-schnell@washingtonenergy.com STAFF USE ONLY Received /Permit # I �I v Accepted by. Date: MAY18H18 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223 • Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #315AAV036070 _ AFUE80% Heat Pump Model #286BNA024K AFUE80% HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other FGas Piping Information Not Applicable: ❑ Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: _ Date 05/18/2018 Applicant Printed Name: Nikki Hyett-Schnell I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 . . CombustionVatiable-Speed 4-Way N/lultipoise Induced I Product Data For even greater comfort and convenience, match the Plus 80V QQ,�ect hl�d� furnace with a two-speed Puron air conditioner or heat pump.This will create a fully communicating system, requiring only 4 EVOLUTION,' p thermostat wires between system components,and troubleshooting can even be done from the outdoor unit without entering the home. HUF Optional remote access through telephone or Internet is also available when combined with a remote connectivity kit. STANDARD FEATURES C!j © e!!Wn e!s� • Evolution" System-match with the Evolution " Control for Evolution " System benefits • Perfect Heat,Perfect Humidity— operation Including Super-dehumidify mode for maximum humidity control Two-stage heating even with single-stage thermostat-patented Adaptive Control Technology Reduced operating sound through low-stage operation and sound elimination combustion system • Variable-speed ECM blower motor Increased SEER ratings for A/C and H/P systems as compared to the Air Conditioning Heating and Refrigeration Institute's standard coil-only ratings when paired with selected Bryant evaporator coils. Matches CFM to cooling system over a wide range of static points • SmartEvap- can lower the humidity level in the home by nearly 10 percent • Four-position furnace:Upflow,Horizontal Right,Horizontal Left,Downflow Thirteen different vent options • Compact design only 33-1/3 in.(847 mm)tall • High-Efficiency Media Filtration Cabinet included The Plus 80V Variable-Speed 4-Way Multipoise Gas Furnace • Washable filter included offers outstanding comfort and electrical efficiency in an 80% • Microprocessor based"smart"control center AFUE furnace.You get all of the benefits of Perfect Heat' and Fan on Plus"-Continuous Fan speed adjustable from thermostat Perfect Humidity-: reduced drafts, reduced sound levels, longer, Adjustable heating air temperature rise more gentle cycles, and less temperature differences between Adapts heating stages to meet demand rooms. Also, it improves indoor air quality, plus provides Up to 12 cooling airflow selections with a wide range of capability outstanding electrical efficiency all year long: Homeowners can Dehumidify mode now economically run constant fan to help eliminate temperature LED diagnostics,non-volatile fault code memory,and self test differences throughout the house and to get better indoor air quality.This Perfect Humidity furnace also increases comfort in the feature summer by wringing out extra humidity. The 315AAV/JAV On-board fuse for transformer protection furnaces are approved for use with natural or propane gas, and the • Patented blocked vent safeguard to ensure proper furnace 315JAV is approved for use in Low NOx Air Management venting Districts. • Insulated blower compartment Bryant Evolution® System When this Plus 80V gas furnace is • HYBRID HEAT®Dual Fuel System compatible matched with the Evolution Control and an air conditioner or heat pump,you will experience the ultimate in Perfect Heat and Perfect • All models are chimney friendly when used with accessory vent kit Humidity through unmatched control of temperature, humidity, • Perfect Light- Igniter indoor air quality, and zoning. The Bryant Evolution System also . Residential installations eligible for consumer financing through allows for worry-free operation through on-screen, text-based the Comfort Credit Program service reminders and equipment malfunction alerts. Received MAY 18 2018 (664mm) (733mm) 26-1/8" 2B-7/B" (FLUI•COLLAR) (641mm) 25-1/4" 22•9118' A (62mm) AIRFLOW (573mm) 1-5/1'. JUNCTION BOX (33mm) tff 13n6" LOCATION p 13/16" 1.118^ (4(43mm) (21mm) 5-15116" C (21mm) 29mm) OUTLET It35mm) r (122mm ( 12'DIA K.O.TNERMOSTAT (22mm) WIRE ENTRY(l7mm) I1NE'7-3/4' 9&♦r ACCESSORY 7/ 'DIA9•�16' t 1-3/4"DIA.RI(i 111) (77mm)(19Tmm�2a^I^t) 7?03 mm)DtA 1217mm) GAS ENTRY(44MM) THERMOSTAT WIRE F. Ar, 1111-Irr 3-15AG'(B4mm) LEFT HANG fiA4 7fir DIA KO WIREENTRY ENTRY ALTERNATE (221nm1 _ 33-5/16" p_ --.—..—._—._— _ 247/B" JUNCTION 8O% 'V (B46mm) (632mm) LOCATIONS(TYP) VENT OUTLET 5 PLACES(TYP) t47l6' L I IM 7/B"(22mm)DIA 7A"DIA ACCESSORY (378mm) ACCESSORY (22mm) 17.m (549mm) 140m --f .11/16" (3Bmm) (17mm) 21-5/6" —1-11/16" (140mm) E 11/1 3-YA' ` �—BOTTOM INLET—_ (43mm) ( ) (95—) (560mm) � 132.mt 22-1/16 I 24^ SIDE INLET i25mm1 CASING (610mm) A04037 NOTES: 1.Two additional 7/8—in.(22 mm)diameter holes are located in the top plate. 2.Minimum return—air openings at furnace,based on metal duct.If flex duct is used,see flex duct manufacturer's recommendations for equivalent diameters. a.For 800 CFM-16—in.(406 mm)round or 14 1/2 x 12—in.(368 x 305 mm)rectangle. b.For 1200 CFM-20—in.(508 mm)round or 14 1/2 x 19 1/2—in.(368 x 495 mm)rectangle. c.For 1600 CFM-22—in.(559 mm)round or 14 1/2 x 22 1/16—in.(368 x 560mm)rectangle. d.For airflow requirements above 1800 CFM,see Air Delivery table in Product Data literature for specific use of single side inlets.The use of both side inlets,a cnmhinatinn of 1 side and the bottom,or the bottom only will ensure adequate return air openings for airflow roquiromontc abovo 1800 CFM. A D E F FLUE SHIPPING FILTER MEDIA FURNACE SIZE CABINET SUPPLY— RETURN— CENTER LINE TOP AND COI I AR* WT CABINET SIZE WIDTH AIR WIDTH AIR WIDTH BOTTOM FLUE COLLAR IN.(mm) LB(KG) IN.(mm) IN.(mm) IN.(mm) IN.(mm) IN.(mm) 036070 14-3/16 12-9/16 12(322) (360) (319) (322) 9-5/16(237) 4(102) 127(58) 16(406) 048090 17-1/2(445) 1403)( 16-1/8(410) 11-9/16(294) 4(102) 151 (68) 16(406) 403) 060110 9-3 21 (533) 1(492) 19-1/2(495) 13-5/16(338) 4(102) 163(74) 20(50B) 066135 24-1/2(622) 22-7/ 23(584) 15-1/16(383) 4(102)t 177(80) 24(610) 066155 24-1/2(622) 2581)( 23(584) 15-1/16(383) 4(102)t 183(83) 24(610) 581) *5 in.or 6 in.(127 or 152 mm)vent connector may be.required in some cases. t5 in.(127 mm)or larger vent is required.Use a 4-5(102-127 mm)or 4-6(102-152 mm)in.vent adapter between furnace and vent connector. t1 mml • 23 ih' i 1600 mm) �4Tnu • 23'1" Wllh Flan�n4 Bmt Oul Mm 1 ( 23 r — Sa/nue)Ounwrm I ) I t 4 A I I I I I I � 1 Fwnace Side I Dutt&4e ) • t Za ri COMCfIM1R�1uC! 61o1s I•-'S' y 1:M.mm7 Media/ Filter Cabinel A B C 16'(406 mm) 17"(432) 61/e(413) 15'(3B1) 20'(505 mm) 21"(533) 01/4"(5141 19'(4B3) 24"(610 mm) 25"(635) 41/4'(6161 23-(SB41 2 A 'ifl'IARNNG, INSTALLATION A AVERTg SEWIff MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION FIR 10 E,EXPLOSN,ASPHMTION HAZARD DISTANCE MINIMALE EN POUCES AUX CONSTRUCTIONS COMBUSTIBLES RISQUE DINCEN D'DiPLOSION ETASPHYXE This faced air furnace is equipped for use with This furnace is approved far UPFLOW,DOWNFLOW,and natural gas at altitudes 0-10,000 It(0-3,050m). HORIZONTAL installations Improper adjustment,alteration,service, An accessory Idt, supplied by the Oetrefoumaiseestappmuvee pour PinstallationHORIZONTALE maintenance,or installation can cause serious manufacturer,shall be used to convert to propane et la circulation d'air VERS LE HAUTetVERS LE BAS. injury or death. gas use or may be required for some natural gas applications. Clearance arrows 1 p Los Whesde Read and follow instructions and precautions in This furnace is for indoor installation in a do not change with nodwWam User's Information Manual provided with this %building constructed on site. furnace Orientation. o I�rf b§mdeISbwai� furnace. Installation and service must be performed This furnace may be installed on combustible by a qualified service agency or the gas supplier. flooring in above or closet at minimum clearance t tine reglage,une modification,un reparation,un as indicated by the diagram from combustible to",Ae tt 0" enretien ou une installation incorrect puet entrainer This furnace may be used with a Type B-1Vent ARRrcK fl 9ptE5 des blessures graves ou la mort. and may be vented in common with other gas ERE a��cr 5e c Suivre les Instructions et les consignes qui figurent fired appliances. fo�k`AON dans la notice d'utilisation qui accompagne ce Cettefoumasea air pulseestequipee Eo sE RV generateur d'air chaud. L'installatlon et 1'entretien pour utilisation aver gaz natural at altitudes `Enf% c oulvar le fournisseur dds e par un reparateur qualifie comprises antra"'050m(0.10,000 pi). 5co e5 Av ON RETIEN p le fabncant,Lifiliser ne trousse de pour passer au gaz propane ou pour version,foumie par (r co ANT 3 M A CAUTION certaines installations au gaz natural. A MISE EN GARDE Celle foumaiseestprevue pour etre `3 Check entire as assembly for leaks after lighting installee dans un batiment ccnstruit sur place. g y g g Cette fournaise titre installee Sur Clearance in inches this appliance. 0 Degagement(po). un plancher combustible clans une alcove ou t Q Verifier tous les elements a gaz pour rechercher dans un garde♦obe an respedant le minimum les futtes apres avoir allume cet appareil. d'espace fibre des matariaux combustibles,tel Vent Clearance to combustibles: qu'indique Sur Is diagramme. For Single Wall vents 6 inches(6 po). N STAL LATION Calls foumaise peut etie utilisee aver un For Type&1 vent type 1 inch(1 po). conduit d'evaaiatlat de Type B-1 ou oonnedee Degagement de Mvent aver combustibles: 1.This furnace must be installed in accordance with the au conduit ommun d'autres apparels a gaz. Pour conduit d'evacuation a pami simple s po(s inches). PP g Pour mndud d'evacuation&T B-11 01inc . manufacturer's instructions and local codes. In the absence of local codes,follow the National Fuel Gas Code ANSI MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION Z223.1/NFPA54 or CSA B-149.1 Gas Installation Code. DOWNFLOW POSITIONS: Ce foumaise a air chaud dolt titre installe eonfommement t Installation on non corbustible floors only. aux instruclions du fabricant et aux codes Iocaux. En For Installation on combustible flooring only when installed on special base,Part No.KGASB0201ALL or I'absence de ces demiers,la norme.ANSI Z223.1/NFPA54 NAHAO1101SB,Coil Assembly,Part No.CAR,CAP,CNPV,CNRV,WENC or WTNC. intitulee National Fuel Gas Code ou les code d'installabon O 18 inches front clearance required for alcove. CSA B149.1. * Indicates supply or return sides when furnace is in the horizontal position.Line contact only permissible 2.This furnace must be installed so there are provisions for beMeen lines formed by intersections of the Top and two Sides of the fumace jacket,and building joists, combustion and ventilation air. See manufacturer's studs or framing. installation information provided with this appliance. DEGAGEMENT MINIMUM EN POUCES AVEC ELEMENTS Ce foumaise a air chaud doit titre installe de maniere a DE CONSTRUCTION COMBUSTIBLES ce qu'ilyait aft suffisamment d'air de ventilation et POUR LA POSITION COURANT DESCENDANT: combustion. Consulter les instructor d'installation du fabricant fournies aver cet appareil. t Pour I'instalation Sur plancher non combustible seulernertL Pour l'installatien Sur un plancher combustible seulement quand on ulilise IS base spedale,piece OPERATION n° KGASBO201ALLcuNAHA01101SB, 1'ensembleserpentin,pieoen°CAR,CAP,CNPV,CNRV, WENC ou WTNC,ou le carter de serperttin. This furnace is equipped with manual reset limit 0 Dens une above,on dolt maintenir un degagement a I'avant de 18 po(450mm). switch(es)in burner compartment to protect against overreat conditions that can resuR from inadequate * La poistion indiquee conceme Is Dote d'entree ou de retour quand IS foumaise est clans la comt;usdon air supply or blocked vent Conditions. position horizontale. 1.Do not bypass limit switches. Le contact nest permis qu'entre les;lignes formees par les intersections du dessus at des 2.If a limit opens,call a quallified serviceman to correct deux cotes de la chemise de la foumaise at lea solives,montant sous cadre de charpente. the condition and reset limit switch. 335137-101 REV. A A08471 ISO 9001:2000 OEWN MEETS DOE RESIDENTIAL CONSERVATION EFFICIENCY I SERVICES PROGRAM STANDARDS. RATING CERTIFIED � ' Before purchasing this appliance,read important eE0t5TERE0 energy cost and efficiency information available r�Ev cenrc¢o from your retailer. 3 SPECIFICATIONS UNIT SIZE 036070 046090 060110 066135 066156 PERFORMANCERATINGS AND 315JAV Upflow;all 315AAV High 66,000 88,000 110,000 132,000 154,000 Input Btuh* Low 43,500 58,000 72,500 87,000 101,500 Nonweatherized ICS 315JAV Downflow/Horizontal High 63,000 84,000 105,000 126,000 147,000 Lo.v 43,500 58,000 72,500 67,000 101,500 315JAV Upflow;all 315AAV High 54,000 71,000 89,000 107,000 125,000 Output Capacity(Btuh)t Low 35,000 47,000 59,000 70,000 82,000 Nonweatherized ICS 315JAV Downflow/Horizontal High 51,000 68,000 85,000 102,00-0 119,000 Low 35,000 47,000 59,000 70,000 82,000 AFUEt 80.0 80.0 80.0 80.0 80.0 High 30-60 40-70 40-70 40-70 45-75 Certified Temperature Rise Range -°F(°C) (17-33) (22-39) (22-39) (22-39) (25-42) Low 30-60 30-60 25-55 25-55 30-60 (17-33) (17-33) (14-30) (14-30) (17-33) Certified External Static Pressure Heat/Cool 0.12/0.50 0.15/0.50 0.20/0.50 0.20/0.50 0.20/0.50 Airflow CFM$ Heating High/Low 1060/615 1090/825 1330/1110 1725/1430 1775/1440 Cooling 1225 1400 2095 2100 2095 Unit Volts-Hertz-Phase 1 15-60-1 Operating Voltage Range Min-Max 104-127 Maximum Unit Amps 9.0 9.6 15.1 14.9 15.0 Maximum Wire Length(Measure 1 Way in Ft(M) 30(9.1) 29(8.8) 29(8.8) 30(9.1) 29(8.8) Minimum Wire Size 14 12 Maximum Fuse or Ckt Bkr Size(Amps)** 15 20 Transformer(24v) 40va External Control Heating 12va Power Available Cooling 35va Air Conditioning Blower Relay Standard CONTROLS Limit Control SPST Heating Blower Control Solid-State Time Operation Burners(Monoport) 3 4 5 6 7 Gas Connection Size 12.3n.NPT GA3 CONTROLS Gas Valve(Redundant) Mfr. White-Rodgers Min.inlet pressure(in.wc) 4.5(Natural Gas) Max.inlet pressure(in.wc) 13.6(Natural Gas) Ignition Device Hot Surface Factory-installed orifice Size 43 BLOWER DATA Direct-Drive Motor HP(PSC) 1/2 1/2 1 Motor Full Load Amps 7.7 7.7 12.8 12.8 12.8 RPM(Nominal)-Speeds 300-1300 300-1300 300-1300 300-1300 300-1300 Blower Wheel Diameter x Width-In.(mm) 10 x 6 10 x 8 11 x 10 11 x 11 11 x 11 (254 x 152) (254 x 203) (279 x 254) (279 x 279) (279 x 279) * Gas input ratings are certified for elevations to 2000 ft.(610 M) In USA for elevations above 2000 ft(610 M),reduce ratings 4 percent for each 1000 ft(305 M)above sea level.Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1-2006 Table F.1 (d)or furnace installation instructions.In Canada,derate the unit 10 percent for elevations 2000 ft to 4500 ft(610 to 1372 M)above sea level. t Capacity in accordance with U.S.Government DOE test procedures. $ Airflow shown is for bottom only return-air supply for the as-shipped speed tap.For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required for each return-air supply.An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16 in.(110 mm)wide,high efficiency media filter. ** Time-delay type is recommended. ICS Isolated Combustion System 4 AIR DELIVERY - CFM (With Filter)* External CFM Static External Static Pressure(ESP)(IN WC) Unit Size Operating Mode Airflow Pressure Setting Range" 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 (In.we) 0w Heat High Heat 1180(1060)t 0-1.0 1160 1165 1175 1180 1180 1180 11 BO 11 B0 1180 1175 TT 1-1/2-Ton Cooling 5 5 - 48 tt 2-Ton Cooling 700 - 0# $ 6 0 -1 - on oo nng - - on KIC Cooling- - 3-1/2-Ton A/C aximum 0-1.0 1395 1400 1 a ow Heat 9B5(825)t 0-1.0 High Heat (1090)t 0-1.0 1190 1205 1210 1210 1210 1210 1210 1210 1210 1200 -1 12-Ton AIC C`ooT-ing__ 2 - # 25 -475-- tt 2-Ton A/C Cooling 70 0-0. 0 675 7 2-1/2-Ton A7G Cooling -1. -Ton�IC Coo ing0-1.01 1005 1005 1015 1035 3-1/2-Ton ooing - 11 0 1 10 4-Ton oo mg 14 - aximum - 1 Low Heat (1110)t 0-1.0 1275 1295 1315 1320 1320 1320 1320 1320 1320 1315 High Heat (1330)t 0-1.0 1460 1465 1475 1475 1475 1475 1475 1475 1465 1465 -TonCoo-ing 700 0-0. 0 00 700 2-1/2-Ton AfC C-667in-g 8 55 - 0# 875 M 875 875 87 T 3-Ton ooing - 1 105 1 69U- 3-1/2-Ton oo in - - on Cooling 1400 14130 1400 1400 1400 1 5-Ton AIC Cooling - . - on oo ing 2100 0-1.0 aximum 22DO 0-1.01 1 Low Heat (1430)t 0-1.0 1700 1700 1700 1700 1700 1695 1700 1695 1685 1670 High Heat (1725)t 0-1.0 1900 1905 1915 1915 1915 1915 1915 1915 1915 1915 tt 2-Ton Cooling 665 2-1/2-Ton ooing 875 0-0.50 870 87 6 8 3-Ton A/C cooTin-g 10 0 0-0.50 10 b - - onCooling -1. 11 -Ton Cooling-- - 1 1 1 -Ion ooing - 1 -T7 o -Ton AIG Coolingf__ - aximum 2200 0-T_.01 2z •z Low Heat 7ri 0-1.0 1715 1715 1715 1715 1715 1705 1710 1705 1705 1695 High Heat (1 )t 0-1.0 1955 1965 1965 1970 1970 1970 1970 1970 1970 1960 t 2-Ton Cooling 700 �__T__ffT0T_ 00 700 ft 2- - on ooing 875 0-0.50t - on A/C Coo-rin-g 10 0- - - on oo ing 1 - - on A/C Cooling- 4 - 1 - on co ing 1 - 1 6-Ton / oo ing - d 1 Maximum 6 - z200 00 'z 0 22 *Actual external static pressure(ESP)can be determined by using the fan laws(CFM 2 proportional to ESP);such as,a system with 1180 CFM at 0.5 ESP would operate at cooling airflow of 1050 CFM at 0.4 ESP and low-heating airflow of 735 CFM at 0.19 ESP. tComfort airflow values are shown in parenthesis. Comfort airflow is selected when the low-heat rise adjustment switch (SWi-3)is OFF and the comfort/efficiency switch(SWi-4)is ON. #Ductwork must be sized for high-heating CFM within the operational range of ESP. **Wattage data provided is for the circulating blower with bottom return and does not include draft inducer,accessories,or gas controls. ttOperation within the blank areas of the chart is not recommended because high-heat operation will be above 1.0 ESP. ***All airflows on 110 size furnace are 5%less on side return only installations. 5 ACCESSORIES L1L;5CR1PT1F)N PART NO. 03�k7c 8010 060110 066135 065155 I-ILB13CAR0016 X X Cartridge Media Filter FILBBCAR0020 X FILBBCAR0024 X X EXPXXUNVO016 X X EZ Flex Media Filter with End Caps EXPXXUNVO020 X EXPXXUNVO024 X X EXPXXFIL0016 X X Replacement EZ Flex Filter Media EXPXXFIL0020 X EXPXXFIL0024 X X KGAFR04OlBl4 X KGAFR0501B17 X External Bottom Return Filter Rack KGAFRO601 B21 X KGAFR0701B24 X X External Side Return Filter Rack KGAFROB01 SRE X X X X X KGAWF1301UFRt S S KGAWF1401 UFR S KGAWF1 Sol UFR S S Unframed Filter,3/4-in.(19 mm) KGAWF1306UFRt X X KGAWF1406UFR X KGAWF1506UFR X X Flue Extension KGAFE0112UPH X X X X X Combustible Floor Base KGASB0201ALL X X X X X Downflow Vent Guard KGAVG0101 DFG X X X X X Vent Extension Kt KGAVE0101 DNH X X X X X Chimney Adapter Kit KGACA02014FC X X X Chimney Adapter Kit KGACA02015FC MX X Natural-to-Propane Conversion Kit* KGANP4601 ALL X X XX Propane-to-Natural Conversion Kit KGAPN3901 ALL X X XX Label Kit KGALB0101 KIT X X XX Air Leakage Kit(Oty 10) KGBAC011 DDGK X X XX ECM Motor Simulator KGASD0301 FMS X X XX Advanced Product Monitor KGAFP0301APM X X X X X KGAHA015ON42 KGAHA025ON43 (factory supplied) KGAHA035ON44 KGAHA045ON45 KGAHAO55ON46 Gas Orifice Kit(Oty 50) KGAHA15SON47 See Installation Instructions for model,altitude,and heat value usages. KGAHA16SON48 KGAHAO65OP54 KGAHA075OP55 KGAHAO85OP56 KGAHA5750125 KGAHA5750130 UV Lights Model UVL Heat/Energy Recovery Ventilator Models HRV or ERV Humidifier Model HUM Electronic or Mechanical Air Cleaner Model EACA or EZXCAB * Factory authorized,field installed.Fuel conversion kits are CSA recognized. t Suitable for Side Return Filter Rack(KGAFROB01 SRE) X=Accessory S=Standard 6 CONTROLS - THERMOSTAT AND ZONING DESCRIPTION PART NO. NON-PROGRAMMABLE For use with 1-speed Air Conditioner-deg.F/C,Auto Changeover T6-NAC,T2-NAC For use with 1-speed Heat Pump-deg.F/C,Auto Changeover T6-NHP T2-NHP* For use with 2-speed Air Conditioner-deg.F/C,Auto Changeover T6-NRH* For use with multi-use/stage configurations-deg.F/C,Auto Changeover/Temperature and Humidity Control T6-PRHT PROGRAMMABLE • SELECTION For use with 1-speed Air Conditioner-deg.F/C,Auto Changeover,7-Day Programmable T6-PAC For use with 1-speed Heat Pump-deg.F/C,Auto Changeover,7-Day Programmable T6-PHP* For use with 2-speed Air Conditioner-deg.F/C,Auto Changeover,7-Day Programmable T6-PRH* For use with 1-speed Air Conditioner-deg.F/C,5-2 Day Programmable T6-PAC For use with multi-stage applications-deg.F/C,Auto Changeover,7-Day Programmable T2-PHP$ For multi-use/stage configurations-deg.F/C,Auto Changeover,7-Day Programmable/Temperature and T6-PRHt Humidity Control ZONING • •• SELECTION Zone Perfect 3-Zone it ZONEBB3ZAC01,ZONEBB3ZHP01 Zone Perfect Plus 2-Zone kit/Temperature and Humidity Control ZONEBB2KIT01-B Zone Perfect Plus 4-Zone kit/Temperature and Humidity Control ZONEBB4KI T 01-B Zone Perfect Plus B-Zone kit/Temperature and Humidity Control ZONEBB8KIT01-B • •N`CONTROLS Evolution" Control Deluxe 7-Day Programmable(Well-mounted system control.) SYSTXBBUID01 Evolution` Control Deluxe Zoning 7-Day Programmable(Wall-mounted control for a multi-zone system.) SYSTXBBUIZ01 Evolution'"' 4-Zone Damper Control Module(Wall-mounted control for a four-zone system.) SYSTXBB4ZCO2 Evolution' Smart Sensor(Optional wall control used to monitor temperature and/or fan control in SYSTXBBSMS01 an individual zone.) Evolution"" Remote Room Sensor(Monitors temperature in an individual zone.) SYSTXBBRRS01 Evolution' System Access Module(Hardware for wireless access and control via phone or internet.) SYSTXBBSAM01 Evolution"" Network Interface Module(Connects Heat Recovery and Energy Recovery Ventilators SYSTBBNIM01tt or older two-speed outdoor models to system.) Decorative Back Plate for Evolution- Control(Decorative wall plate.) SYSTXXXBPU01 * Model HP and 2S thermostat must be field converted to air conditioner operation. t Thermidistat Control can be configured for multiple use and staging.It must be configured for each specific application. t Dual Fuel thermostat is used with furnace and heat pump application. ** When applied with Bryant's Perfect Humidity-series 355AAV,315AAV/JAV and FIE Indoor Models tt Must be installed in Dual-Fuel Evolution system applications. 7 I 14 SEE NOTES:1,2,4,7,8,9 SEE NOTES:1,2,3,4,7,8,9 SEE NOTES:1,2,4,5,7,8,9 UPFLOW UPFLOW DOWNFLOW A02050 A02059 A02061 1 SEE NOTES:1,2,3,4,5,7,8,9 SEE NOTES: 1,2,3,4,5,7,8,9 SEE NOTES: 1,2,4,5,6,7,8,9 DOWNFLOW DOWNFLOW DOWNFLOW A02060 A02063 A02062 Venting Notes 1. For common vent,vent connector sizing and vent material:United States,latest edition of the National Fuel Gas Code(NFGC),ANSI Z223.1/NFPA 54. In Canada,latest edition of the National Standards of Canada,Natural Gas and Propane Installation Code(NSCNGPIC),CSA B149.1. 2. Immediately increase to 5-in.(127 mm)vent connector outside furnace casing when 5-in.(127 mm)vent connector required,refer to Note 1. 3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when KGAVG0101 DFG is used in downflow position. 4. Type B vent where required,refer to Note 1. 5. 4—in. (102 mm)single wall vent must be used inside furnace casing and the KGAVG0101 DFG Downflow Vent Guard Kit. 6. Accessory Downflow Vent Guard Kit,KGAVG0101 DFG required in downflow installations with bottom vent configuration. 7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kit, KGACA02014FC and KGACA02015FC for sizin and complete application details. 8. Secure vent connector to furnace elbow with(2?corrosion-resistant sheet metal screws,space approximately 180' apart. 9. Secure all other single wall vent connector joints with(3)corrosion-resistant screws spaced approximately 120° apart. Secure Type B vent connectors per vent connector manufacturer's recommendations. 8 GUIDE SPECIFICATION S Gas Furnace Inducer Motor 315AAV/JAV Inducer motor shall be soft mounted to reduce vibration General transmission. Draft Safeguard Switch SYSTEM DESCRIPTION Draft Safeguard Switch (blocked vent safeguard) shall Furnish a fixed capacity gas-fired be factory installed to reduce the possibility of vent gas furnace for use with natura gas or propane (factory infiltration due to a blocked or restricted vent pipe. authorized conversion kit required for propane); furnish Heat Exchangers cold air return plenum;furnish side(external)filter rack. Heat exchangers shall be a 4-Pass 20 gage aluminized QUALITY ASSURANCE steel of fold-and-crimp sectional design when applied Unit will be designed, tested and constructed to the operating under negative pressure. current ANSI Z 21.47/CSA 2.3 design standard for Controls gas-fired central furnaces. Control shall include a micro-processor based Unit will be 3rd party certified by CSA to the current integrated electronic control board with at least 11 service ANSI Z 21.47/CSA 2.3 design standard for gas-fired troubleshooting codes displayed via diagnostic flashing central furnaces. LED light on the control, a self-test feature that checks all Unit will carry the CSA Blue StarOR and Blue Flame@ major functions of the furnace within one minute, and a labels. replaceable automotive-type circuit protection fuse. Unit efficiency testing will be performed per the current Multiple operational settings available including, separate DOE test procedure as listed in the Federal Register. blower speeds for low heat, high heat, low cooling, high Unit will be certified for capacity and efficiency and cooling and continuous fan. Continuous fan speed may be listed in the latest GAMA Consumer's Directory of adjusted from the thermostat. Cooling airflow will be Certified Efficiency Ratings. selectable between 350 or 400 CFM per ton of air Unit shall carry the current Federal Trade Commission conditioning.Features will also include temporary reduced Energy Guide efficiency label. airflow in the cooling mode for improved DELIVERY,STORAGE AND HANDLING dehumidification when an Evolution'" Control or Unit shall be shipped as single package only and is Thermidistat@ is selected as the thermostat. stored and handled per unit manufacturer's OPERATING CHARACTERISTICS recommendations. Heating Capacity shall be Btuh input; WARRANTY(for inclusion by specifying engineer)r) Btuh output capacity. U.S. and Canada only. Warranty certificate available Fuel Gas Efficiency shall be 80%AFUE. upon request. Air delivery shall be cfm minimum at Products 0.50 in.we external static pressure. Dimensions shall be: depth in. (mm); EQUIPMENT width in. (mm); heig' i1 t in. (mm) Components shall include: slow-opening gas valve to (casing only). Height shall be in. (mm) with reduce ignition noise, regulate gas flow, with electric A/C coil and in. (mm) overall with switch gas shut-off; flame proving sensor, hot surface plenum. igniter, pressure switch assembly, flame rollout switch, ELECTRICAL REOUIREMENTS blower and inducer assembly, 40va transformer; Electrical supply shall be 115 volts, 60 Hz, low-voltage(heating)(heating/cooling)thermostat. single-phase (nominal). Minimum wire size shall Blower Wheel and Blower Motor be A G; maximum fuse size or circuit breaker Galvanized blower wheel shall be centrifugal type, shall be Amps. statically and dynamically balanced. Blower motor of PSC SPECIAL FEATURES type shall be permanently lubricated with sealed bearings, Refer to section of the product data sheet identifying of hp, and shall be multiple-speed direct drive. accessories and descriptions for specific features and Blower motor shall be soft mounted to the blower scroll to available enhancements. reduce vibration transmission. Filters Furnace may have reusable-type filters. Filter shall be in. (mm)(x) in. (mm). Casing Casing shall be of .030-in. (.76 mm) thickness minimum,pre-painted galvanized steel. 02009 Bryant Heating&Cooling Systems e 7310 W.Morris St.-Indianapolis,IN 46231 Printed in U.S.A. Edition Date:2/09 Catalog No. PDS315A.45.6 Manufacturer reserves the right to discontinue,or change at any time,specifications or designs without notice and without incurring obligations. Replaces:PDS 315A.45.5 10 i I' I � o I. SEE NOTES: 1,2,4,5,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL RIGHT HORIZONTAL RIGHT A02068 A02070 I SEE NOTES:1,2,4,7,8,9 HORIZONTAL RIGHT A02009 t' J o � � O SEE NOTES: 1,2,4,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT A02064 A02065 O It SEE NOTES: 1,2,4,5,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT A02066 A02067 9 Launa Peterson From: Launa Peterson Sent: Tuesday, May 29, 2018 1:42 PM To: 'nhyett-schnell@washingtonenergy.com' Cc: Kristin Foster Subject: 19215 46th Drive NE,Arlington,WA 98223 When installing a heat pump we need a site plan showing the location and distance to the property line. Please provide a site plan for the above address. Thank you, Launa Peterson Permit Techncian City of Arlington 18204 59th Avenue NE Arlington, WA 98223 360-403-3551 ti I 1 1 � S ' 4Ln T M 1} A ce A tJ1 A i i Vairiable-Speed 4-Way Multipoise Induced Combustion Gas Fumace ]=®R Sizes 04 Product Data For even greater comfort and convenience, match the Plus 80V 4e y0�� furnace with a two-speed Puron air conditioner or heat pump.This will create a fully communicating system, requiring only 4 EVOLUTION thermostat wires between system components,and troubleshooting can even be done from the outdoor unit without entering the home. ,Ct Firl, Optional remote access through telephone or Internet is also available when combined with a remote connectivity kit. _ _o NEI 1!!!� STANDARD FEATURES • Evolution System-match with the Evolution- Control for Evolution"" System benefits • Perfect Heat,Perfect Humidity- operation 1!!� lftw�0 Including Super-dehumidify mode for maximum humidity control Two-stage heating even with single-stage thermostat-patented Adaptive Control Technology Reduced operating sound through low-stage operation and rti sound elimination combustion system tom✓ • Variable-speed ECM blower motor Increased SEER ratings for A/C and H/P systems as compared to the Air Conditioning Heating and Refrigeration Institute's standard coil-only ratings when paired with selected Bryant evaporator coils. Matches CFM to cooling system over a wide range of static points • SmartEvap- can lower the humidity level in the home by nearly 10 percent • Four-position furnace:Upflow,Horizontal Right,Horizontal Left,Downflow Thirteen different vent options • Compact design only 33-1/3 in.(847 mm)tall • High-Efficiency Media Filtration Cabinet included The Plus 80V Variable-Speed 4-Way Multipoise Gas Furnace • Washable filter included offers outstanding comfort and electrical efficiency in an 80%n • Microprocessor based"smart"control center AFUE furnace. You get all of the benefits of Perfect Heat' and Fan on Plus' -Continuous Fan speed adjustable from thermostat Perfect Humidity-: reduced drafts, reduced sound levels, longer, Adjustable heating air temperature rise more gentle cycles, and less temperature differences between Adapts heating stages to meet demand rooms. Also, it improves indoor air quality, plus provides Up to 12 cooling airflow selections with a wide range of capability outstanding electrical efficiency all year long: Homeowners can Dehumidify mode now economically run constant fan to help eliminate temperature LED diagnostics,non-volatile fault code memory,and self test differences throughout the house and to get better indoor air quality.This Perfect Humidity furnace also increases comfort in the feature summer by wringing out extra humidity. The 315AAV/JAV On-board fuse for transformer protection furnaces are approved for use with natural or propane gas, and the • Patented blocked vent safeguard to ensure proper furnace 315JAV is approved for use in Low NOx Air Management venting Districts. • Insulated blower compartment Bryant Evolution® System When this Plus 80V gas furnace is • HYBRID HEAT@ Dual Fuel System compatible matched with the Evolution Control and an air conditioner or heat pump,you will experience the ultimate in Perfect Heat and Perfect • All models are chimney friendly when used with accessory vent kit Humidity through unmatched control of temperature, humidity, • Perfect Light"" Igniter indoor air quality, and zoning. The Bryant Evolution System also • Residential installations eligible for consumer financing through allows for worry-free operation through on-screen, text-based the Comfort Credit Program service reminders and equipment malfunction alerts. (664mm) (733mm) 26-1/8" 28-7/8" (FLUE COLLAR) (41 25-5-11/4. U 2-7/16" 22-9/16" A (62mm) (573mm) 1-5/16" AIRFLOW JUNCTION BOX (33mm) 19" 13/16" LOCATION D m 13/16" 1-1/8" E(48TMM) (21mm) 5-15/16" C (21mm) 413/16„ 29m ) ULET (135mm) r (122mm i o i 1/2"DIA.K.O.THERMOSTAT (22 mm) WIRE EN TRY(13mm) 9-5/8" 7W DIA 8-9116" I 11 rn)(193/4" 244mm ACCESSORY (217mm) GAS ENTRY 4mmAND (17mm)(197mm)( ) 1/2"(13 mm)DIA. BBI� it 1/2" THERMOSTAT WIRE ENTRY (292mm) 0000 3-15/i6"(84mm) LEFT HAND GAS 7/8"DIA.K.O.WIRE ENTRY ENTRY ALTERNATE (22f001)_-.—_.—_--.- 33-5/16" f�----'—'---------- 24-7/8" JUNCTION BOX P (846mrn) i (632mm) LOCATIONS(TYP) VENT OUTLET I 5 PLACES(TYP) 14-7/8" 7/8"(22mm)DIA. 7/8"DIA.ACCESSORY (378mm) ACCESSORY (22mm) 5-1/2"(140mm) 11/16" 5-1/2" (17mm) (549mm) (140mm) E 11/16" 3-3/4" �1-1/2"(38mm) 1-1/4" 21-5/8" 1-11116" (17mm) (g5mm) (560mm) (32mm) BOTTOM INLET (43mm) 22-1/16" 1" 24• _ SIDE INLET (25mm) CASING (610mm) A04037 NOTES: 1.Two additional 7/8—in.(22 mm)diameter holes are located in the top plate. 2.Minimum return—air openings at furnace,based on metal duct.If flex duct is used,see flex duct manufacturer's recommendations for equivalent diameters. a.For 800 CFM-16—in.(406 mm)round or 14 1/2 x 12—in.(368 x 305 mm)rectangle. b.For 1200 CFM-20—in.(508 mm)round or 14 1/2 x 19 1/2—in.(368 x 495 mm)rectangle. c.For 1600 CFM-22—in.(559 mm)round or 14 1/2 x 22 1/16—in.(368 x 560mm)rectangle. d.For airflow requirements above 1800 CFM,see Air Delivery table in Product Data literature for specific use of single side inlets.The use of both side inlets,a combination of 1 side and the bottom,or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM. A D E F FLUE SHIPPING FILTER MEDIA CABINET SUPPLY— RETURN— CENTER LINE TOP AND FURNACE SIZE WIDTH AIR WIDTH AIR WIDTH BOTTOM FLUE COLLAR COLLAR* WT. CABINET SIZE IN.(mm) IN.(mm) IN.(mm) IN.(mm) IN.(mm) LB(KG) IN.(mm) 036070 14-3/16 12-9/16 12-11/16 9-5/16(237) 4(102) 127(58) 16(406) (360) (319) (322) 048090 17-1/2(445) 15-7/8 16-1/8(410) 11-9/16(294) 4(102) 151 (68) 16(406) (403) 060110 21 (533) 19-3/8 19-1/2(495) 13-5/16(338) 4(102) 163(74) 20(508) (492) 066135 24-1/2(622) 22-7/8 23(584) 15-1/16(383) 4(102)t 177(80) 24(610) (581) 066155 24-1/2(622) 22-7/8 23(584) 15-1/16(383) 4(102)t 183(83) 24(610) (581) *5 in.or 6 in.(127 or 152 mm)vent connector may be required in some cases. t5 in.(127 mm)or larger vent is required.Use a 4-5(102-127 mm)or 4-6(102-152 mm)in.vent adapter between furnace and vent connector. �25 k" 651 mm) � 23'b" (600 mm) (b P4mhm�� 23 W i With FIa2ngQ Bent Out (594 mm) ,2 ~ O 587 mm)Opening I I I I I I I rn I I O A I I I I I I Furnace Sitle I Duct Side I 23'h" mm Centerfne39cre)w Slots f5"/."i (146 mm) Media/ Filter Cabinet A B C 16"(406 mm) 17'(432) 61/4'(413) 15"(381) 20"(508 mm) 21'(533) 20 V4''(514) 19"(483) 24"(610 mm) 25'(635) 241/4"(616) 23"(584) 2 A WARNING INSTALLATION A AVERTISSEMENT MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION FIRE,EXPLOSION,ASPHYXIATION HAZARD DISTANCE MINIMALE EN POLICES AUX CONSTRUCTIONS COMBUSTIBLES This forced air furnace is equipped for use with This furnace is approved for UPFLOW,DOWNFLOW,and RISQUE D'INCENDIE D'EXPLOSION ET ASPHYXIE natural gas at altitudes 0-10,000 It(0-3,050m). HORIZONTAL installations. Improper adjustment,alteration,service, An accessory kit, supplied by the Cettefoumaise est approuvee pour l'installationHORIZONTALE maintenance,or installation can cause serious manufacturer,shall be used to convert to propane et la circulation d'airVERS LE HAUTet VERS LE BAS. injury or death. gas use or may be required for some natural gas applications. Clearance arrows zsanm Les fleshes de d6gagement Read and follow instructions and precautions in This furnace is for indoor installation in a do not changewth ne change pas avec User's Information Manual provided with this ? I'orienration de la foumaise. P building constructed on site. furnace orientation. o furnace. Installation and service must be performed This furnace may be installed on combustible by a qualified service agency or the gas supplier. flooring in alcove or closet at minimum clearance as indicated by the diagram from combustible tt 09 Une r&glage,une modification,un reparation,un material. OB �' of 0" enretien ou une installation incorrect puet entrainer This furnace may be used with a Type B-1 Vent A R R'ERE K Soj ES des blessures graves ou la mort. and may be vented in common with other gas ERE �NPP\SE Suivre les instructions et les consignee qui figurent fired appliances. Fo\SQ` 0,A1 dans la notice d'utilisation qui accompagne ce Cette foumaise A air pulsb est 6quip6e FP�pN SE gen&rateur d'air chaud. L'installation et 1'entretien pour utilisation aver gaz nature) et altitudes L6NTRE G oulvar le fournisseuu&dpar a azn r&parateur qualifi& comprises entre 0 3,050m(010,000 pi). Sao es AV oN RETIEN 24' p 9 Utiliser une trousse de conversion,foumie par Go ANT IBM— A CAUTION le fabr cant,pour passer au gaz propane ou pour 0„ T MI certaines installations au gaz naturel. § y (7612M.) A M IS E EN GARDE Cette foumaise Est pr6vue pour titre o 0 installee dans un batiment constmit Sur place. o w Check entire gas assembly for leaks after lighting m o Clearance in inches this appliance. Cette foumaise peut titre installee Sur 0" D6gagement(po). un plancher combustible clans une alcove ou t 0 Verifier tous les elements a gaz pour rechercher clans un garde-robe en respectant le minimum les fuites apr&s avoir allume cet appareil. d'espace fibre des mat6riaux combustibles,tel Vent Clearance to combustibles: qu"indiqu6 Sur le diagramme. For Single Wall vents 6 inches(6 po). N STAL LATI C N Cette foumaise peut titre utilis6e avec un For Type B-1 vent type 1 inch(1 po). conduit d"6vacuation de Type B-1 ou connectbe D6gagement de 1"6vent avec combustibles: Pour conduit d"evacuation a paroi simple 6 po(6 inches). 1.This furnace must installed in accordance with the au conduit ommun d'autres appareils a gaz. Pour conduit d"evacuation de Type B-1 1 po 1 inch). manufacturer's instructions and local codes. In the absence of local codes,follow the National Fuel Gas Code ANSI MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION Z223.1/NFPA54 or CSA B-149.1 Gas Installation Code. DOWNFLOw POSITIONS: Ce foumaise a air chaud dolt titre install&conform&ment t Installation on noncombustible floors only. aux instructions du fabricant et aux codes locaux. En For Installation on combustible flooring only when installed on special base,Part No.KGASBO201ALL or ('absence de ces demiers,la nonme.ANSI Z223.1/NFPA54 NAHA01101 SB,Coil Assembly,Part No.CAR,CAP,CNPV,CNRV,WENC or WTNC. intitul&e National Fuel Gas Code ou les code d'installation 0 18 inches front clearance required for alcove. CSA B149.1. * Indicates supply or return sides when furnace is in the horizontal position. Line contact only permissible 2.This furnace must be installed so there are provisions for between lines formed by intersections of the Top and two Sides of the furnace jacket,and building joists, combustion and ventilation air. See manufacturer's studs or Taming. installation information provided with this appliance. DEGAGEMENT MINIMUM EN POUCES AVEC ELEMENTS Ce foumaise a air chaud doit titre install&de mani&re a DE CONSTRUCTION COMBUSTIBLES ce qu"ilyait aft suffisamment d'air de ventilation et POUR LA POSITION COURANT DESCENDANT: combustion. Consulter les instructions d'installation du fabricant foumies avec Cet apparel. t Pour Pinstallation sur plancher non combustible seulement. Pour('installation sur un plancher combustible seulement quand on utilise la base sp6aale,piece OPERATION rP KGASBO201ALLou NAHA01101SB, 1"ensemble serpentin,piece rf CAR,CAP,CNPV,CNRV, WENC ou WTNC,ou le carter de serpentin. This furnace is equipped with manual reset limit 0 Dans une alcove,on dolt maintenir un d6gagement A I"avant de 18 po(450mm). switch(es)in bumer compartment to protect against * La poistion indiqu6e conceme le c6t6 d'entr6e ou de retour quand la foumaise est dans la overheat conditions that can result from inadequate combustion air supply or blocked vent conditions. position horzontale. 1.Do not bypass limit switches. Le contact nest penmis qu"entre les;Iignes form6es par les intersections du dessus et des 2.If a limit opens,call a quallified serviceman to correct deux sates de la cherrise de la foumaise et les solives,montant sous cadre de charpente. the condition and reset limit switch. 335137-101 REV. A A08471 ISO 9001:2000 oESIG/y MEETS DOE RESIDENTIAL CONSERVATION SP cmEFFICIENCY I SERVICES PROGRAM STANDARDS. RATING , CERTIFIED ama $A' Before purchasing this appliance,read important REGISTERED energy cost and efficiency information available �ERTIFlEO cean Fieo from your retailer. 3 SPECIFICATIONS UNIT SIZE 036070 048090 060110 066135 066155 PERFORMANCERATINGS AND 315JAV Upflow;all 315AAV High 66,000 88,000 110,000 132,000 154,000 Input Btuh* Low 43,500 58,000 72,500 87,000 101,500 Nonweatherized ICS 315JAV Downflow/Horizontal High 63,000 84,000 105,000 126,000 147,000 Low 43,500 58,000 72,500 87,000 101,500 315JAV Upflow;all 315AAV High 54,000 71,000 89,000 107,000 125,000 Output Capacity(Btuh)t Low 35,000 47,000 59,000 70,000 82,000 Nonweatherized ICS 315JAV Downflow/Horizontal High 51,000 68,000 85,000 102,000 119,000 Low 35,000 47,000 59,000 70,000 82,000 AFUEt 80.0 80.0 80.0 80.0 80.0 High 30-60 40-70 40-70 40-70 45-75 Certified Temperature Rise Range -°F(°C) (17-33) (22-39) (22-39) (22-39) (25-42) Low 30-60 30-60 25-55 25-55 30-60 (17-33) (17-33) (14-30) (14-30) (17-33) Certified External Static Pressure Heat/Cool 0.12/0.50 0.15/0.50 0.20/0.50 0.20/0.50 0.20/0.50 Airflow CFM$ Heating High/Low 1060/615 1090/825 1330/1110 1725/1430 1775/1440 Cooling 1225 1400 2095 2100 2095 ELECTRICAL Unit Volts-Hertz-Phase 115-60-1 Operating Voltage Range Min-Max 104-127 Maximum Unit Amps 9.0 9.6 15.1 14.9 15.0 Maximum Wire Length(Measure 1 Way in Ft(M) 30(9.1) 29(8.8) 29(8.8) 30(9.1) 29(8.8) Minimum Wire Size 14 12 Maximum Fuse or Ckt Bkr Size(Amps)** 15 20 Transformer(24v) 40va External Control Heating 12va Power Available Cooling 35va Air Conditioning Blower Relay Standard • -• Limit Control SPST Heating Blower Control Solid-State Time Operation Burners(Monoport) 3 4 5 6 7 Gas Connection Size 1/2-in.NPT GAS CONTROLS Gas Valve(Redundant) Mfr. White-Rodgers Min.inlet pressure(in.wc) 4.5(Natural Gas) Max.inlet pressure(in.wc) 13.6(Natural Gas) Ignition Device Hot Surface Factory-installed orifice Size 43 BLOWERDATA Direct-Drive Motor HP(PSC) 1/2 1/2 1 1 1 Motor Full Load Amps 7.7 7.7 12.8 12.8 12.8 RPM(Nominal)-Speeds 300-1300 300-1300 300-1300 300-1300 300-1300 Blower Wheel Diameter x Width- In.(mm) 10 x 6 10 x 8 11 x 10 11 x 11 11 x 11 (254 x 152) (254 x 203) (279 x 254) (279 x 279) (279 x 279) * Gas input ratings are certified for elevations to 2000 ft.(610 M) In USA for elevations above 2000 ft(610 M),reduce ratings 4 percent for each 1000 ft(305 M)above sea level.Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1-2006 Table F1 (d)or furnace installation instructions.In Canada,derate the unit 10 percent for elevations 2000 ft to 4500 ft(610 to 1372 M)above sea level. t Capacity in accordance with U.S.Government DOE test procedures. $ Airflow shown is for bottom only return-air supply for the as-shipped speed tap.For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required for each return-air supply.An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16 in.(110 mm)wide,high efficiency media filter. ** Time-delay type is recommended. ICS Isolated Combustion System 4 AIR DELIVERY - CFM (With Filter)* External CFM Static External Static Pressure(ESP) (IN WC) Unit Size Operating Mode Airflow Pressure Setting Range* 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 (in.wc) 36070 TT Low Heat 735 615 t 0-0.50 735 735 735 735 7 5 High Heat 1180 0-1.0 1160 1165 1175 1180 1180 1180 1180 1180 1180 1175 (1060)t tt 1-1/2-Ton Cooling 525 0-0.50t 515 500 500 490 485 tt 2-Ton A/C Cooling 700 0-0.50t 690 680 675 680 675 2-1/2-TonCooling 875 0-1.0t 875 875 875 870 865 855 850 835 825 820 3-TonCooling 1050 0-1.0t 1050 1050 1050 1050 1050 1050 1045 1035 1020 1000 3-1/2-TonCooling 1225 0-1.0 1220 1225 1225 1225 1225 1220 1205 1190 1185 1170 Maximum 1400 0-1.0 1395 1400 1400 1400 1395 1385 1370 1340 1300 1245 048090 Low Heat 985 825 t 0-1.0 950 970 985 985 985 985 985 985 985 980 High Heat 1210 0-1.0 1190 1205 1210 1210 1210 1210 1210 1210 1210 1200 (1090)t tt 1-1/2-Ton A/C Cooling 525 0-0.50t 525 520 525 495 475 tt 2-Ton A/C Cooling 700 0-0.50t 680 680 680 675 670 2-1/2-TonCooling 875 0-1.0t 815 845 845 855 850 850 845 835 820 805 3-TonCooling 1050 0-1.0t 1005 1005 1015 1035 1040 1040 1035 1030 1025 1010 3-1/2-Ton ACooling 1225 0-1.0 1190 1200 1200 1205 1205 1215 1205 1200 1185 1170 4-Ton A/C Cooling 1400 0-1.0 1350 1370 1390 1390 1400 1390 1380 1380 1360 1340 Maximum 1600 0-1.0 1595 1600 1600 1600 1595 1555 1505 1465 1430 1390 060110*** Low Heat 1320 0-1.0 1275 1295 1315 1320 1320 1320 1320 1320 1320 1315 (1110)T High Heat 1475 0-1.0 1460 1465 1475 1475 1475 1475 1475 1475 1465 1465 (1330)t tt 2-Ton A/C Cooling 700 0-0.50t 700 700 700 700 700 tt 2-1/2-Ton A/C Cooling 875 0-0.50t 875 875 875 875 875 tt 3-Ton A/C Cooling 1050 0-0.50t 1050 1050 1050 1050 1050 3-1/2-Ton ACooling 1225 0-1.0t 1225 1225 1225 1225 1225 1225 1225 1225 1225 1225 4-TonCooling 1400 0-1.0t 1400 1400 1400 1400 1400 1400 1400 1400 1400 1400 5-TonCooling 1750 0-1.0t 1750 1750 1750 1750 1750 1750 1750 1750 1740 1725 6-Ton ACooling 2100 0-1.0 2100 2100 2100 2100 2090 2075 2055 2040 2005 1970 Maximum 2200 0-1.0 2200 2190 2190 2180 2155 2145 2125 2100 2080 2020 066135 Low Heat 1700 0-1.0 1700 1700 1700 1700 1700 1695 1700 1695 1685 1670 (1430)t High Heat 1915 0-1.0 1900 1905 1915 1915 1915 1915 1915 1915 1915 1915 (1725)t tt 2-Ton A/C Cooling 700 0-0.50t 700 700 700 700 665 tt 2-1/2-Ton A/C Cooling 875 0-0.50t 870 870 865 865 865 tt 3-Ton A/C Cooling 1050 0-0.50t 1010 1030 1050 1050 1050 3-1/2-Ton ACooling 1225 0-1.0t 1155 1180 1200 1210 1220 1225 1225 1225 1225 1225 4-TonCooling 1400 0-1.0t 1395 1400 1400 1400 1400 1400 1400 1390 1375 1355 5-TonCooling 1750 0-1.0t 1740 1750 1750 1750 1735 1740 1735 1730 1715 1700 6-Ton ACooling 2100 0-1.0 2075 2085 2090 2100 2100 2100 2090 2080 2055 2025 Maximum 2200 0-1.0 2180 2195 2200 2200 2200 2200 2185 2165 2140 2095 155 Low Heat 1715 0-1.0 1715 1715 1715 1715 1715 1705 1710 1705 1705 1695 (1440)t High Heat 1970 0-1.0 1955 1965 1965 1970 1970 1970 1970 1970 1970 1960 (1775)t tt 2-Ton A/C Cooling 700 0-0.50t 700 700 700 700 680 tt 2-1/2-Ton A/C Cooling 875 0-0.50t 865 875 875 865 865 tt 3-Ton A/C Cooling 1050 0-0.50t 1015 1020 1035 1045 1050 3-1/2-Ton ACooling 1225 0-1.0t 1160 1185 1215 1225 1225 1225 1225 1225 1225 1225 4-TonCooling 1400 0-1.0t 1385 1400 1400 1400 1400 1400 1395 1395 1380 1360 5-TonCooling 1750 0-1.0t 1745 1750 1750 1750 1745 1740 1745 1745 1740 1735 6-TonCooling 2100 0-1.0 2055 2070 2080 2085 2095 2100 2100 2100 2090 2065 Maximum 2200 0-1.0 2175 2190 2200 2200 2200 2200 2200 2200 2180 2160 *Actual external static pressure(ESP)can be determined by using the fan laws(CFM 2 proportional to ESP);such as,a system with 1180 CFM at 0.5 ESP would operate at cooling airflow of 1050 CFM at 0.4 ESP and low-heating airflow of 735 CFM at 0.19 ESP. tComfort airflow values are shown in parenthesis. Comfort airflow is selected when the low-heat rise adjustment switch(SWi-3)is OFF and the comfort/efficiency switch(SWi-4)is ON. #Ductwork must be sized for high-heating CFM within the operational range of ESP. **Wattage data provided is for the circulating blower with bottom return and does not include draft inducer,accessories,or gas controls. ttOperation within the blank areas of the chart is not recommended because high-heat operation will be above 1.0 ESP ***All airflows on 110 size furnace are 5%less on side return only installations. 5 ACCESSORIES DESCRIPTION PART NO. 036070 060110 066135 066155 FILBBCAR0016 X X Cartridge Media Filter FILBBCAR0020 X FILBBCAR0024 X X EXPXXUNVO016 X X EZ Flex Media Filter with End Caps EXPXXUNVO020 X EXPXXUNVO024 X X EXPXXFIL0016 X X Replacement EZ Flex Filter Media EXPXXFIL0020 X EXPXXFIL0024 X X KGAFR0401B14 X KGAFR0501B17 X External Bottom Return Filter Rack KGAFR0601B21 X KGAFR0701B24 X X External Side Return Filter Rack KGAFR0801 SRE X X X X X KGAWF1301UFRt S S KGAWF1401UFR S KGAWF1501UFR S S Unframed Filter,3/4-in.(19 mm) KGAWF1306UFRt X X KGAWF1406UFR X KGAWF1506UFR X X Flue Extension KGAFE0112UPH X X X X X Combustible Floor Base KGASB0201ALL X X X X X Downflow Vent Guard KGAVG0101 DFG X X X X X Vent Extension Kit KGAVE0101 DNH X X X X X Chimney Adapter Kit KGACA02014FC X X X Chimney Adapter Kit KGACA02015FC X X Natural-to-Propane Conversion Kit* KGANP4601ALL X X X X X Propane-to-Natural Conversion Kit KGAPN3901ALL X X X X X Label Kit KGALB0101 KIT X X X X X Air Leakage Kit(Qty 10) KGBAC011ODGK X X X X X ECM Motor Simulator KGASD0301 FMS X X X X X Advanced Product Monitor KGAFP0301 APM X X X X X KGAHAO15ON42 KGAHA025ON43 (factory supplied) KGAHA035ON44 KGAHA045ON45 KGAHA055ON46 Gas Orifice Kit(Qty 50) KGAHA1550N47 See Installation Instructions for model,altitude,and heat value usages. KGAHA1650N48 KGAHA065OP54 KGAHA075OP55 KGAHA085OP56 KGAHA5750125 KGAHA5750130 UV Lights Model UVL Heat/Energy Recovery Ventilator Models HRV or ERV Humidifier Model HUM Electronic or Mechanical Air Cleaner Model EACA or EZXCAB * Factory authorized,field installed.Fuel conversion kits are CSA recognized. t Suitable for Side Return Filter Rack(KGAFR0801 SRE) X=Accessory S=Standard 6 CONTROLS - THERMOSTAT AND ZONING DESCRIPTION PART NO. NON-PROGRAMMABLE For use with 1-speed Air Conditioner—deg.F/C,Auto Changeover T6—NAC,T2—NAC For use with 1-speed Heat Pump—deg.F/C,Auto Changeover T6—NHP,T2—NHP* For use with 2-speed Air Conditioner—deg.F/C,Auto Changeover T6—NRH* For use with multi-use/stage configurations—deg.F/C,Auto Changeover/Temperature and Humidity Control T6—PRHt PROGRAMMABLE • SELECTION For use with 1-speed Air Conditioner—deg.F/C,Auto Changeover,7-Day Programmable T6—PAC For use with 1-speed Heat Pump—deg.F/C,Auto Changeover,7-Day Programmable T6—PHP* For use with 2-speed Air Conditioner—deg.F/C,Auto Changeover,7-Day Programmable T6—PRH* For use with 1-speed Air Conditioner—deg.F/C,5-2 Day Programmable T6—PAC For use with multi-stage applications—deg.F/C,Auto Changeover,7-Day Programmable T2—PHP# For multi-use/stage configurations—deg.F/C,Auto Changeover,7-Day Programmable/Temperature and T6—PRHt Humidity Control ZONING • -• SELECTION Zone Perfect 3-Zone kit ZONEBB3ZAC01,ZONEBB3ZHP01 Zone Perfect Plus 2-Zone kit/Temperature and Humidity Control ZONEBB2KIT01-B Zone Perfect Plus 4-Zone kit/Temperature and Humidity Control ZONEBB4KIT01-B Zone Perfect Plus 8-Zone kit/Temperature and Humidity Control ZONEBB81KIT01-B • •N-**CONTROLS Evolution" Control Deluxe 7-Day Programmable(Wall-mounted system control.) SYSTXBBUID01 Evolution" Control Deluxe Zoning 7-Day Programmable(Wall-mounted control for a multi-zone system.) SYSTXBBUIZ01 Evolution" 4-Zone Damper Control Module(Wall-mounted control for a four-zone system.) SYSTXBB4ZCO2 Evolution" Smart Sensor(Optional wall control used to monitor temperature and/or fan control in SYSTXBBSMS01 an individual zone.) Evolution" Remote Room Sensor(Monitors temperature in an individual zone.) SYSTXBBRRS01 Evolution" System Access Module(Hardware for wireless access and control via phone or internet.) SYSTXBBSAM01 Evolution" Network Interface Module(Connects Heat Recovery and Energy Recovery Ventilators SYSTBBNIM01tt or older two-speed outdoor models to system.) Decorative Back Plate for Evolution" Control(Decorative wall plate.) SYSTXXXBPU01 * Model HP and 2S thermostat must be field converted to air conditioner operation. t Thermidistat Control can be configured for multiple use and staging.It must be configured for each specific application. t Dual Fuel thermostat is used with furnace and heat pump application. ** When applied with Bryant's Perfect Humidity"" series 355AAV,315AAV/JAV and FE Indoor Models tt Must be installed in Dual-Fuel Evolution system applications. 7 -uu= �JLLULL11 :7-A I I II it Ki i i li ii ill G� i i O O •o• SEE NOTES: 1,2,4,7,8,9 SEE NOTES: 1,2,3,4,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 UPFLOW UPFLOW DOWNFLOW A02058 A02059 A02061 uuuul I I O O I O I I I = I e e e e I e e I I I I I I I I I I I lri I SEE NOTES:1,2,3,4,5,7,8,9 SEE NOTES: 1,2,3,4,5,7,8,9 SEE NOTES: 1,2,4,5,6,7,8,9 DOWNFLOW DOWNFLOW DOWNFLOW A02060 A02063 A02062 Venting Notes 1. For common vent,vent connector sizing and vent material: United States,latest edition of the National Fuel Gas Code(NFGC),ANSI Z223.1/NFPA 54. In Canada,latest edition of the National Standards of Canada,Natural Gas and Propane Installation Code(NSCNGPIC),CSA B149.1. 2. Immediately increase to 5-in. (127 mm)vent connector outside furnace casing when 5-in. (127 mm)vent connector required,refer to Note 1. 3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when KGAVG0101 DFG is used in downflow position. 4. Type B vent where required,refer to Note 1. 5. 4—in. (102 mm)single wall vent must be used inside furnace casing and the KGAVG0101 DFG Downflow Vent Guard Kit. 6. Accessory Downflow Vent Guard Kit, KGAVG0101 DFG required in downflow installations with bottom vent configuration. 7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kit, KGACA02014FC and KGACA02015FC for sizing and complete application details. 8. Secure vent connector to furnace elbow with (2)corrosion-resistant sheet metal screws,space approximately 180' apart. 9. Secure all other single wall vent connector joints with (3)corrosion-resistant screws spaced approximately 120' apart. Secure Type B vent connectors per vent connector manufacturer's recommendations. 8 Ili WW o° o. �� I Ig II II I o° o. SEE NOTES: 1,2,4,5,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL RIGHT HORIZONTAL RIGHT A02068 A02070 o° loll II�I I � III III I II I I i 00, SEE NOTES: 1,2,4,7,8,9 HORIZONTAL RIGHT A02069 LLLU11111111 �\ I III III II I A ° I 0 0 SEE NOTES: 1,2,4,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT A02064 A02065 LLWWII Lo i I Iq Ii�Ii I U III�I I 0 0 0 o 0° SEE NOTES: 1,2,4,5,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT A02066 A02067 9 GUIDE SPECIFICATIONS Gas Furnace Inducer Motor 315AAV/JAV Inducer motor shall be soft mounted to reduce vibration General transmission. Draft Safeguard Switch SYSTEM DESCRIPTION Draft Safeguard Switch (blocked vent safeguard) shall Furnish a fixed capacity gas-fired be factory installed to reduce the possibility of vent gas furnace for use with natural gas or propane (factory infiltration due to a blocked or restricted vent pipe. authorized conversion kit required for propane); furnish Heat Exchangers cold air return plenum;furnish side(external)filter rack. Heat exchangers shall be a 4-Pass 20 gage aluminized QUALITY ASSURANCE steel of fold-and-crimp sectional design when applied Unit will be designed, tested and constructed to the operating under negative pressure. current ANSI Z 21.47/CSA 2.3 design standard for Controls gas-fired central furnaces. Control shall include a micro-processor based Unit will be 3rd party certified by CSA to the current integrated electronic control board with at least 11 service ANSI Z 21.47/CSA 2.3 design standard for gas-fired troubleshooting codes displayed via diagnostic flashing central furnaces. LED light on the control, a self-test feature that checks all Unit will carry the CSA Blue Star@ and Blue Flame@ major functions of the furnace within one minute, and a labels. replaceable automotive-type circuit protection fuse. Unit efficiency testing will be performed per the current Multiple operational settings available including, separate DOE test procedure as listed in the Federal Register. blower speeds for low heat, high heat, low cooling, high Unit will be certified for capacity and efficiency and cooling and continuous fan. Continuous fan speed may be listed in the latest GAMA Consumer's Directory of adjusted from the thermostat. Cooling airflow will be Certified Efficiency Ratings. selectable between 350 or 400 CFM per ton of air Unit shall carry the current Federal Trade Commission conditioning. Features will also include temporary reduced Energy Guide efficiency label. airflow in the cooling mode for improved DELIVERY,STORAGE AND HANDLING dehumidification when an Evolution- Control or Unit shall be shipped as single package only and is ThermidistatO is selected as the thermostat. stored and handled per unit manufacturer's OPERATING CHARACTERISTICS recommendations. Heating Capacity shall be Btuh input; WARRANTY(for inclusion by pecifying engineer) Btuh output capacity. U.S. and Canada only. Warranty certificate available Fuel Gas Efficiency shall be 80%AFUE. upon request. Air delivery shall be cfm minimum at Products 0.50 in.we external static pressure. EQUIPMENT Dimensions shall be: depth in. (mm); width in. (mm); height in. (mm) Components shall include: slow-opening gas valve to (casing only). Height shall be in. (mm) with reduce ignition noise, regulate gas flow, with electric A/C coil and in. (mm) overall with switch gas shut-off; flame proving sensor, hot surface plenum. igniter, pressure switch assembly, flame rollout switch, ELECTRICAL REQUIREMENTS blower and inducer assembly, 40va transformer; Electrical supply shall be 115 volts, 60 Hz, low-voltage(heating)(heating/cooling)thermostat. single-phase (nominal). Minimum wire size shall Blower Wheel and Blower Motor be AWG; maximum fuse size or circuit breaker Galvanized blower wheel shall be centrifugal type, shall be Amps. statically and dynamically balanced. Blower motor of PSC SPECIAL FEATURES type shall be permanently lubricated with sealed bearings, Refer to section of the product data sheet identifying of hp, and shall be multiple-speed direct drive. accessories and descriptions for specific features and Blower motor shall be soft mounted to the blower scroll to available enhancements. reduce vibration transmission. Filters Furnace may have reusable-type filters. Filter shall be in. (mm)(x) in. (mm). Casing Casing shall be of .030-in. (.76 mm) thickness minimum,pre-painted galvanized steel. ©2009 Bryant Heating&Cooling Systems a 7310 W.Morris St.a Indianapolis,IN 46231 Printed in U.S.A. Edition Date:2/09 Catalog No. PDS315A.45.6 Manufacturer reserves the right to discontinue,or change at any time,specifications or designs without notice and without incurring obligations. Replaces:PDS 315A.45.5 10 Permit#: 1982 Permit Date: 05/30/18 Permit Type: RESIDENTIAL MECHANICAL Project Name: Wiliams Applicant Name: Washington Energy Services Applicant Address: 3909 196th Street SW Applicant, City, State, Zip: Lynnwood, WA 98036 Contact: Nikki Hyett-Schnell Phone: 206-378-6648 Email: nhyett-schnell@washingtonenergy.com Scope of Work: Install furnace &heat pump Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 05/30/2018 Permit Expires: Form Permit Type: Status: IN PROCESS Assigned To: Launa Black Property Parcel# Address Legal Description Owner Name Owner Phone Zoning WILLIAMS 00928200000600 19215 46TH DR NE CHRISTOPHER M Residence Single Family -Detached &CHERILYN C Contractors Contractor Primary Contact Phone Address Contractor Type License License# WASHINGTON Karen Matheney 2063786648 3909 196th Street CONSTRUCTION COA 603 522 032 ENERGY SERVICES SW CONTRACTOR WASHINGTON Karen Matheney 2063786648 3909 196th Street CONSTRUCTION Labor&WASHIES85INS ENERGY SERVICES SW CONTRACTOR Industries Fees Fee Description Notes Amount Air Cond.Unit Btu/h<100>; $25.00 Btu/hp>500 Forced Air Heat fee per Btu $25.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Total $100.00 Attached Letters Date Letter Description 05/30/2018 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 05/30/2018 Craig Olson 70196893 cc $100.00 Outstanding Balance $0.00 Notes Date Note Created By: 02/20/2019 Expired.Filed in address files.No final was done. Raelynn Jones Uploaded Files Date File Name 05/30/2018 3549502-1982 Issued Permit.pdf 05/30/2018 3546903-Residential Mechanical 1J4XjEiA2Eowz5.pdf 05/30/2018 3546904-19215 46th Dr NE site plan.pdf 05/30/2018 3546905-attachments C015031000017664943 059nzJRCeFxIFk410WZQ 315AAV036070.pdf RESIDENTIAL MECHANICAL PERMIT APPLICATION t�N Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: 19215 46th Dr NE Project Description-Installing furnace and heat pump. Owner: Chris Williams Address. 19215 46th Dr NE City. Arlington State:wa Zip Code: 98223 Phone: 3606535997 Email:chris.williams@hotmail.com Applicant: Washington energy Services Address: 3909 196th St SW City: Lynnwood State.wa Zip Code: 98036 Phone. 2063786648 Email. NHyett-Schnell@washingtonenergy.com CONTRACTOR INFORMATION Contractor Name:Washignton energy services Address: 3909 196th St SW City: Lynnwood State vva Zip Code: 98036 License Number:washies851ns Expiration: 0907/19 Phone: 2063786648 Email:NHyett-schnell@washingtonenergy.com STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 Y. RESIDENTIAL MECHANICAL PERMIT APPLICATION SING Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #315AAV036070 AFUE 80% Heat Pump Model #286BNA024K AFUE80% HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: ❑ Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: d5a513bei e6' Date: 05/18/2018 Applicant Printed Name: Nikki Hyett-Schnell I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2