Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
17608 Redhawk Dr_BLD1612_2026
CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address: 17608 Redhawk Drive Permit#: 1612 Parcel#:00809200004900 Valuation:2800,00 OWNER APPLICANT CONTRACTOR Name:BERGERON CAROLYN M Name: Blue Flame Heating and A/C Name:BLUE FLAME HEATING AND AIR Address: 17608 REDHAWK DR Address:7116 220th Street SW,#1 Address:7116 220 ST SW City,State Zip:ARLINGTON,WA 98223-5939 City,State Zip: Mountlake Terrace,WA 98043 City,State Zip:MOUNTLK TERRACE,WA 98043 Phone: Phone:425-771-7139 Phone:425-771-7139 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:BLUE FLAME HEATING AND AIR Name: Address:7116 220 ST SW Address: City,State,Zip:MOUNTLK TERRACE,WA 98043 City,State,Zip: Phone:425-771-7139 Phone: LIC#: BLUEFFH835MQ EXP: 7/20/2019 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL l AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. [BC110/IRCI10. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City ofArlingto re ed on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date WreasKry Date CONDITIONS Approved as submitted. Adhere to the installation of model #ADD1A060A9241A AFUE 80.0 THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC)WILL REQUIRE SEPARATE PERMISSION, PERMIT FEES Date Description Fee Amount 8/21/2017 Furnace $25.00 8/21/2017 Mechanical Permit Base Fee $25.00 8/21/2017 Processing/Technology Fee $25.00 Total Due: S75.00 Total Payment: $0.00 Balance Due: S7.5.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon COMMERCIAL MECHANICAL • PERMIT APPLICATION Department of Community & Economic Development City of Arlington• 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF CONSTRUCTION DRAWINGS AND ALL OTHER INFORMATION OUTLINED IN THE MECHANICAL PERMIT SUBMITTAL REQUIREMENTS, IF APPLICABLE. Type of Permit: ❑ New Installation ❑✓ Replacement F1 Alteration Project Address: 17608 REDHAWK DR Parcel #: 00809200004900 LIKE IN KIND FURNACE REPLACEMENT Project Description: Valuation:2800 Owner: CAROLYN BERGERON Phone#:360-403-8919 Address: 17608 REDHAWK DR City: ARLINGTON State:WA Zip:98223 Email Address: N/A KAILANA MUNIZ Contact Person: Phone #: 425-771-7139 Address: 7116 220TH ST SW#1 City:Mountlake State: WA Zip: 98043 Email Address:INFO@BLUEFLAMECOMFORT.COM Contractor Name:BLUE FLAME HEATING AND AIR Phone #: 425-771-7139 Contractor Address: 7116 220TH ST SW#1 City: Mountlake State:WA Zip: 98043 Email:SAME AS ABOVE Contact Person: KAILANA MONIZ Contractor License Number: BLUEFFH865MQ Expiration: 03/18 Please indicate type of number of appliances: FURNACE 1 CONDENSING UNIT GAS PIPING OUTLET BOILER HEAT PUMP(multi-split) UNIT HEATER CHILLER HEAT PUMP(mini-split) PAINT BOOTH COOLER HEAT PUMP(other) TYPE I HOOD AC(air cooled) HEAT REJECTION EQUIP TYPE II HOOD AC(water cooled) VENTILATION SYSTEM AST AC(evaporator) PACKAGED UNIT UST AC(VRF) DRYER OTHER I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- .. ,m .�. described property will b rules and regulation of the fate of Washington. I '���Gn�c� 08/17/2017 Applicants Signature: Date Applicants Printed Name: KAILANA MONIZ FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received 6/16LP Page 1 of 1 Community and Economic Development , Building Division INSPECTION RECORD SHALL REMAIN AT JOB Building construction shall not commence until permit SITE holder or agent has posted this Inspection Record Card in a conspicuous place on the premises. OWNER: Carolyn Bergeron CONTRACTOR: Blue Flame Heating and Air JOB ADDRESS:17608 Redhawk Drive NE OWNERADDRESS: 17608 Redhawk Drive NE USE of BUILDING: SFR PLAT NAME: Description of work: Replace Gas Furnace LOT# PERMIT NO: 1612 Sprinklered: CONDITIONS: See Permit DATE ISSUED:8.21.2017 TYPE GROUP DEPARTMENT INSPECTION DATE DATE PASS FAIL INITIALS FOOTING BUILDING FOUNDATION INSPECTION LINE UNDERFLOOR (360)403-3417 SHEARWALL PLUMBING (groundwork) GAS PIPING(groundwork) ROUGH PLUMBING ROUGH GAS PIPING ROUGH HEATING&VENTILATION FRAMING INSULATION WALLBOARD(SHEAR/RATING) ROOF DRAINAGE DEVELOPMENT STORM INFILTRATION SERVICES GRADING INSPECTION LINE CURB GUTTER&SIDEWALK (360)403-3417 LANDSCAPE DRIVEWAY UTILITIES SIDE SEWER INSPECTION LINE SEWER CLEANOUT/FINAL (360)403-3508 WATER SERVICE INSPECTION WATER SERVICE FINAL CROSS CONNECTION FINAL (360)403-3417 FINAL INSPECTION All sections must be signed off prior to final inspection Electrical must be signed off prior to final inspection COMMENTS: 4kaiea" S odwid ADD1 A060-SPEC-2 HEATING & AIR C O N D I T I O N I N G TAG: • - • Downf low / Horizontal Induced Draft 5,$„ Gas Furnace 14-1/2" �13-1/4" 24-1/2° 28" ADD1 A060A9241 A 19-5/8" 5/8" SIDE PANEL 1/2" CUTOUT FOR 5"0 SIDE PANEL CUTOUT y HORIZONTAL FOR HORIZONTAL VENTING VENTING THROUGH THE CABINET 9 5/8" THROUGH 7/8"DIA.HOLES THE CABINET ELECTRICAL 3-1/2 5" 1 CONNECTION 1 i 40" 7/8"DIA.K.O. 3-3/8 i ELECTRICAL ` T' CONNECTION FLUE - (ALTERNATE) 3/4 )I \ 2_1/8" OPENING 31 2-1/8" 13' 29-1/2" 04 O 0 0 1-1/2"DIA. O 0 0 20-1/4" K.O.GAS (LTERNATOE) 3/4" . 3-15/16" 0 10" 12-3/8" ` 10.. 0 19" 0 5-5/16" 1/2" 2-1/16" 1-1/2"DIA.HOLE GAS CONNECTION FURNACE AIRFLOW(CFM)VS.STATIC PRESSURE (ins.w.g.) MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 ADD1A060A9241A 4- HIGH - Black 1200 1155 1111 1056 1001 924 848 774 701 3- MED.-HIGH - Blue 1025 988 951 905 859 797 735 646 558 2 - MED.-LOW-Yellow 838 808 779 742 704 646 588 502 415 1 - LOW- Red 722 689 656 618 579 528 478 376 275 CFM VS.TEMPERATURE RISE MODEL CFM (CUBIC FEET PER MINUTE) 700 1 800 1 900 1 1000 1100 ADD1 A060A9241 A 63 156 1 49 1 44 1 40 0 2008 American Standard Heating & Air Conditioning General Data o TYPE Downf low/Horizontal VENT COLLAR—Size(in.) 4 Round RATINGS s HEAT EXCHANGER Input BTUH 60,000 Type-Fired Alum.Steel Capacity BTUH(ICS) O 48,000 -Unfired AFUE 80.0 Gauge(Fired) 20 Temp.rise(Min.-Max.)'F. 35-65 ORIFICES—Main BLOWER DRIVE DIRECT Nat.Gas.Qty.—Drill Size 3-45 Diameter-Width(In.) 10 x 7 L.P.Gas Qty.—Drill Size 3—56 No.Used 1 GAS VALVE Redundant-Single Stage Speeds(No.) 4 PILOT SAFETY DEVICE CFM vs.in.w.g. See Fan Performance Type Hot Surface Ignition Motor HP 1/5 BURNERS—Type Multiport Inshot R.P.M. 1075 Number 3 Volts/Ph/Hz 115/1/60 POWER CONN.—V/Ph/Hz < 115/1/60 COMBUSTION FAN-Type Centrifugal Ampacity(In Amps) 5.5 Drive-No.Speeds Direct-1 Max.Overcurrent Protection(amps) 15 Motor HP-RPM 1/50-3180 PIPE CONN.SIZE(IN.) 1/2 Volts/Ph/Hz 115/1/60 DIMENSIONS H x W x D F.L.Amps 1.09 Crated(In.) 41 x 15-1/2 x 29-1/2 FILTER—Furnished? No Uncrated(In.) 40 x 14-1/2 x 28-1/2 Type Recommended High Velocity WEIGHT Hi Vel.(No.-Size-Thk.) 2- 14 x 20- 1 in. Shipping(Lbs.)/Net(Lbs) 129/119 O Central Furnace heating designs are certified by the American Gas Association Inc.Laboratories. ®Ratings shown are for elevations up to 2000 feet.For elevations above 2000 feet;Ratings should be reduced at the rate of 4%for each 1000 feet above sea level. (D Based on U.S.Government Standard Tests. ®The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. Mechanical Specifications NATURAL GAS MODELS—Central heat- BURNERS — Multi-port, in-shot burners STYLING — Heavy gauge steel and ing furnace designs are certified by the will give years of quiet and efficient service. "wraparound" cabinet construction is American Gas Association for both natu- All models can be converted to L.P. gas used in the cabinet with baked-on enamel ral and L.P. gas. Limit setting and rating without changing burners. finish for strength and beauty. The heat data were established and approved un- INTEGRATED SYSTEM CONTROL—Ex- exchanger section of the cabinet is com- der standard rating conditions using Ameri- clusively designed operational program pro- pletely lined with foil-faced fiberglass insu- can National Standards Institute standards. vides total control of furnace limit sensors, lation. This results in quiet and efficient SAFE OPERATION — The Integrated blowers, gas valve, flame control and in- operation due to the excellent acoustical System Control has solid state devices, cludes self diagnostics for ease of service. and insulating qualities of fiberglass. which continuously monitor for presence FEATURES AND GENERAL OPERA- AIR DELIVERY—The multispeed,direct- offlame,when the system is in the heating drive blower motor, with sufficient airflow TION —These High Efficiency Gas Fur- mode of operation. Dual solenoid combi- range for most heating and cooling re- naces employ a Hot Surface Ignition sys- nation gas valve and regulator provide tem, which eliminates the waste of a con- extra safety. cooling will switch from heating m stantly burning pilot. The integrated sys- cooling speeds on demand from room tem control lights the main burners upon a QUICK HEATING—Durable,cycle tested, thermostat. The blower door safety switch demand for heat from the room thermo- heavy gauge aluminized steel heat ex- will prevent or terminate furnace operation seat. Complete front service access. changer quickly transfers heat to provide when the blower door is removed. (Fan warm conditioned air to the structure. Low relay and 35VA control transformer is stan- a. Low energy power venter. energy power vent blower, to increase dard). b. Vent proving differential switch. efficiency and provide discharge of gas fumes to the outside,allows common vent- ing with hot water heater. /♦m I " hm,� S*"t rd wp Library HEATING & AIR CERTIFIED Product Section - C O N D I T 1 O N I N G ® Product Furnace American Standard Model ADD1 Heating&Air Conditioning 1) S I GN Literature Type Submittal 6200 Troup Highway Sequence - Tyler,TX 75707 sA Date 02/08 Since American Standard Heating&Air Conditioning hasa File No. ADDlA060-SPEC-2 policy of continuous product and product data improvement,it C Q Supersedes ADD1A060A9241A reserves the rightto change specifications and design without notice. CITY OF ARLINGTON 23 8 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address: 17608 Redhawk Drive Permit 4: 1612 Parcel#:00809200004900 Valuation:2800 00 OWNER APPLICANT CONTRACTOR Name:BERGERON CAROLYN M Name: Blue Flame Heating and A/C Name:BLUE FLAME HEATING AND AIR Address: 17608 REDHAWK DR Address:71 l6 220th Street SW,#1 Address:7116 220 ST SW City,State Zip:ARLINGTON,WA 98223-5939 City, State Zip:Mountlake Terrace,WA 98043 City,State Zip:MOUNTLK TERRACE,WA 98043 Phone: Phone:425-771-7139 Phone:425-771-7139 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:BLUE FLAME HEATING AND AIR Name: Address:7116 220 ST SW Address: City,State,Zip:MOUNTLK TERRACE,WA 98043 City,State,Zip: Phone:425-771-7139 Phone: LIC#:BLUEFFH835MQ EXP: 7/20/2019 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: ] OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI l0/IRCI 10. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlingto re ed on your sales tax return form and coded City ofArlington#3101, Signature Print Name Date easy I y t7o Date CONDITIONS Approved as submitted. Adhere to the installation of model #ADDIA06OA9241A AFUE 80.0 THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC_)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 8/21/2017 Furnace $25.00 8/21/2017 Mechanical Permit Base Fee $25.00 8/21/2017 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: S75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon r ....,� .. ;:. 1 - �' C :M- -E-RC4 AL M E C f _ .XN 1 CAL y PERMIT APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE- Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF CONSTRUCTION DRAWINGS AND ALL OTHER INFORMATION OUTLINED IN THE MECHANICAL PERMIT SUBMITTAL REQUIREMENTS, IF APPLICABLE. Type of Permit: New Installation ❑✓ Replacement ❑ Alteration Project Address: 17608 REDHAWK DR Parcel #: 00809200004900 LIKE IN KIND FURNACE REPLACEMENT Project Description: Valuation:2800 Owner: CAROLYN BERGERON Phone#:360-403-8919 Address: 17608 REDHAWK DR City:ARLINGTON State:WA Zip:98223 Email Address: N/A Contact Person: Phone#: 425-771-7139 Address: 7116 220TH ST SW#1 City:Mountlake State: WA Zip: 98043 Email Address:INFO@BLUEFLAMECOMFORT.COM Contractor Name:BLUE FLAME HEATING AND AIR Phone #: 425-771-7139 Contractor Address: 7116 220TH ST SW#1 ----City:Mountlake State:WA Zip:98043 Email-SAME AS ABOVE Contact Person: KAILANA MONIZ Contractor License Number: BLUEFFH865MQ Expiration: 03/18 Please indicate type of number of appliances: FURNACE 1 CONDENSING UNIT GAS PIPING OUTLET BOILER HEAT PUMP(multi-split) UNIT HEATER CHILLER HEAT PUMP(mini-split) PAINT BOOTH COOLER HEAT PUMP(other) TYPE I HOOD AC(air cooled) HEAT REJECTION EQUIP TYPE II HOOD AC(water cooled) VENTILATION SYSTEM AST AC(evaporator) PACKAGED UNIT UST AC(VRF) DRYER OTHER I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in acc?- e- "•'tie laws,rules and regulation of the State of Washington. Applicants Signature: Date 08/17/2017 Applicants Printed Name: KAIIANA MONIZ FOR STAFF USE ONLY Received Permit# Apteid- Amount Received Receipt# 0 t 6116LP Page 1 of 1 . „ s �,i ' h i '� 1 AAw? o S-Azod"d ADD1 A060-SPEC-2 HEATING & AIR C O N D I T I O N I N G TAG: - Downflow / Horizontal Induced Draft Gas Furnace 5!8" 14-1/2' 13-1l4" 24-1/2" 28" ADD1 A060A9241 A / 19-5/8` 518" SIDE PANEL 112 CUTOUT FOR 5"0 SIDE PANEL CUTOUT HORIZONTAL FOR HORIZONTAL VENTING VENTING THROUGH THE CABINET 9-5/8" THROUGH 7/8"DIA.HOLES \ THE CABINET ELECTRICAL 3-1/2 5" 1 � CONNECTION 1 3-3/8 1 40" 7/8"DIA.K.O. . ELECTRICAL ` 7'. 1�� � CONNECTION FLUE (ALTERNATE) 3!� `` 2-1/8` OPENING 3 _ 1 cc _ ` i. r91 �a 2-1/8" 13 d 29 112" ` A Q 1-1/2"DIA. G:Q 20-1/a` K.O.GAS CONNECTION Q 0 0 0 (ALTERNATE) 10" 12-3/8" Q 10' 19" � 8-1/4" 5-5118" 1/2" 2-1/16" 1-1/2"DIA.HOLE V-1 GAS CONNECTION FURNACE AIRFLOW(CFM)VS.STATIC PRESSURE(ins.w g.) MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 ADD1A060A9241A 4- HIGH- Black 1200 1155 1111 1056 1001 924 848 774 701 3- MED.-HIGH- Blue 1025 988 951 905 859 797 735 646 558 2- MED.-LOW-Yellow 838 808 779 742 704 646 588 502 415 1 - LOW- Red 722 689 656 618 579 528 478 376 275 CFM VS.TEMPERATURE RISE MODEL CFM (CUBIC FEET PER MINUTE) 700 800 900 1000 1100 Received ADD1 A06OA9241 A 63 1 56 1 49 1 44 40 AUG 17 2017 0 2008 American Standard Heating & Air Conditioning General Data o TYPE Downflow/Horizontal VENT COLLAR—Size(in.) 4 Round RATINGS V HEAT EXCHANGER Input BTUH 60,000 Type-Fired Alum.Steel Capacity BTUH(ICS) O 48,000 -Unfired AFUE 80.0 Gauge(Fired) 20 Temp.rise(Min:Max.)°F. 35-65 ORIFICES—Main BLOWER DRIVE DIRECT Nat.Gas.Qty.—Drill Size 3—45 Diameter-Width(In.) 10 x 7 L.P.Gas Oty.—Drill Size 3—56 No.Used 1 GAS VALVE Redundant-Single Stage Speeds(No.) 4 PILOT SAFETY DEVICE CFM vs.in.w.g. See Fan Performance Type Hot Surface Ignition Motor HP 1/5 BURNERS—Type Multiport Inshot R.P.M. 1075 Number 3 Volts/Ph/Hz 115/1/60 POWER CONN.—V/Ph/Hz (D 115/1/60 COMBUSTION FAN-Type Centrifugal Ampacity(In Amps) 5.5 Drive-No.Speeds Direct-1 Max.Overcurrent Protection(amps) 15 Motor HP-RPM 1/50-3180 PIPE CONN.SIZE(IN.) 112 Volts/Ph/Hz 115/1/60 DIMENSIONS H x W x D F.L.Amps 1.09 Crated(In.) 41 x 15-1/2 x 29-1/2 FILTER—Furnished? No Uncrated(In.) 40 x 14-1/2 x 28-1/2 Type Recommended High Velocity WEIGHT Hi Vel.(No.-Size-Thk.) 2-14 x 20-1 in. Shipping(Lbs.)/Net(Lbs) 129/119 O Central Furnace heating designs are certified by the American Gas Association Inc.Laboratories. ®Ratings shown are for elevations up to 2000 feet.For elevations above 2000 feet;Ratings should be reduced at the rate of 4%for each 1000 feet above sea level. ®Based on U.S.Government Standard Tests. ®The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. Mechanical Specifications NATURAL GAS MODELS—Central heat- BURNERS — Multi-port, in-shot burners STYLING — Heavy gauge steel and ing furnace designs are certified by the will give years of quiet and efficient service. "wraparound" cabinet construction is American Gas Association for both natu- All models can be converted to L.P. gas used in the cabinet with baked-on enamel ral and L.P. gas. Limit setting and rating without changing burners. finish for strength and beauty. The heat data were established and approved un- INTEGRATED SYSTEM CONTROL—Ex- exchanger section of the cabinet is com- derstandard rating conditions using Ameri- clusively designed operational program pro- pletely lined with foil-faced fiberglass insu- can National Standards Institute standards. vides total control of furnace limit sensors, lation. This results in quiet and efficient SAFE OPERATION — The Integrated blowers, gas valve, flame control and in- operation due to the excellent acoustical System Control has solid state devices, eludes self diagnostics for ease of service. and insulating qualities of fiberglass. which continuously monitor for presence FEATURES AND GENERAL OPERA- AIR DELIVERY—The multispeed,direct- of flame,when the system is in the heating drive blower motor, with sufficient airflow TION —These High Efficiency Gas Fur- mode of operation. Dual solenoid combi- range for most heating and cooling re- naces employ a Hot Surface Ignition sys- nation gas valve and regulator provide tem,which eliminates the waste of a con- extra safety. coolie ents, will switch from heating m stantly burning pilot. The integrated sys- ooling speeds on demand from room tem control lights the main burners upon a QUICK HEATING—Durable,cycle tested, thermostat. The blower door safety switch demand for heat from the room thermo- heavy gauge aluminized steel heat ex- will prevent or terminate furnace operation seat. Complete front service access. changer quickly transfers heat to provide when the blower door is removed. (Fan warm conditioned air to the structure. Low relay and 35VA control transformer is stan- a. Low energy power venter. energy power vent blower, to increase dard). b. Vent proving differential switch. efficiency and provide discharge of gas fumes to the outside,allows common vent- ing with hot water heater. SrA. ��N,cel�,`1/C�aw! fl dSP Library HEATING & AIR CERTIFIED Product Section CONN DITIONIN G ® Product Furnace American Standard Model ADD1 Heating&Air Conditioning So Literature Type Submittal 6200 Troup Highway Sequence - Tyler,TX 75707 Date 02/08 Since American Standard Heating&Air Conditioning has a File No. ADDlA060-SPEC-2 policy of continuous product and product dataimprovement,it Supersedes ADD1A060A9241A reservestherighttochangespecilicationsanddesignwithout not ce. 8/21/2017 BLUE FLAME HEATING AIR&ELCTR I Iluur 1?si�anl Cuntz:ct Search L&I \-Z I71dCr I Idp- NIV I,&f Safety&Health Claims&Insurance Workplace Rights Trades &Licensing Washington State Department of " Labor & industries BLUE FLAME HEATING AIR & ELCTR Owner or tradesperson 7116 220TH ST SW#1 MOUNTLAKE TERRACE,WA 98043 Principals 425-771-7139 DONALDSON,GEORGE,PRESIDENT SNOHOMISH County CHAISSON,DENNIS J,TREASURER Doing business as BLUE FLAME HEATING AIR&ELCTR WA UBI No. Business type 604105 991 Corporation Governing persons DENNIS CHAISSON GEORGE DONALDSON; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. BLUEFFH835MQ Effective—expiration 07/20/2017—07/20/2019 Bond Nationwide Mutual Ins Co $12,000.00 Bond account no. 7900456789 Received by L&I Effective date 07/20/2017 07/06/2017 Expiration date Until Canceled Insurance American Fire&Casualty Co $1,000,000.00 Policy no. BKA57145709 Received by L&I Effective date 07/20/2017 03/17/2017 Expiration date 03/17/2018 Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings Help us irnpro fe https://secure.ini.wa.gov/verify/Detail.aspx?UBI=604105991&LIC=BLUEFFH835MQ&SAW= 1/2 I I 8/21/2017 BLUE FLAME HEATING AIR&ELCTR No lawsuits against the bond or savings accot"_")luring the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 644,698-00 .. .................... Doing business as BLUE FLAME HEATING AIR&ELEC Estimated workers reported Quarter 2 of Year 2017"21 to 30 Workers" L&I account contact T1/IDA HAYNES(360)902-5635-Email:HAYN235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. ©Washington State Dept.of Labor&Industries,Use of this site is subject to the laws of the state of Washington. Help us irnprove https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=604105991&LIC=BLUEFFH835MQ&SAW= 2/2 1 Permit#: 1612 Permit Date: 08/21/17 Permit Type: RESIDENTIAL MECHANICAL Project Name: Bergeron Applicant Name: Blue Flame Heating and A/C Applicant Address: 7116 220th Street SW, #I Applicant, City, State, Zip: Mountlake Terrace,WA 98043 Contact: Kailana Montz Phone: 425-771-7139 Email: info@blueflamecomfort.com Scope of Work: Replace Gas Furnace Valuation: 2800.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: Permit Expires: Form Permit Type: Status: EXPIRED Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00809200004900 17608 REDHAWK DR BERGERON 111 Single Family CAROLYN M Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# BLUE FLAME RODNEY CONSTRUCTION HEATINGANDAIR WALKER 425-771-7139 7116 220 ST SW CONTRACTOR COA 601 837 949 BLUE FLAME RODNEY CONSTRUCTION Labor&BLUEFFH825RM HEATING AND AIR WALKER 425-771-7139 7116 220 ST SW CONTRACTOR Industries Fees Fee Description Notes Amount Forced Air Heat fee per Btu $25.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Total $75.00 Attached Letters Date Letter Description 08/21/2017 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 08/21/2017 KAILANA MONIZ 66021305 cc $75.00 Outstanding Balance $0.00 Notes Date Note Created By: 12/12/2019 Permit not signed.Filed under address Raelynn Jones 08/21/2017 Emailed permit for signature.KF Kristin Foster Uploaded Files Date File Name 08/21/2017 2541854-1612 Specs.pdf 08/21/2017 2541855-1612 Residential Mechanical Apnlication.pdf