Loading...
HomeMy WebLinkAbout17020 Smokey Point Blvd_BLD1992_2018 Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 59th Avenue NE • Arlington, WA 98223 • Phone (360) 403-3551 Page 1 of 1 Permit Number: Permit Type: Address/Parcel: Completed (Month/Year): Land Use ˆ Notice of Decision ˆ Staff Report ˆ Application ˆ Narrative ˆ Legal Description ˆ Vicinity Map ˆ Site Plan ˆ Landscape Plan ˆ Complete Streets Checklist ˆ Traffic Impact Analysis ˆ Snohomish County Traffic Mitigation Offer ˆ WSDOT Traffic Offer Form ˆ Tree Survey ˆ Stormwater Drainage Report ˆ Geotech Report ˆ Critical Area Evaluation Form ˆ SEPA Checklist ˆ Public Notice Material ˆ Noticing and Related Documents ˆ Water / Sewer Availability Certificate ˆ Unanticipated Discovery Plan Form ˆ Aerial Photo of Site ˆ Proposed Building Materials ˆ Lighting Plans and Lighting Cut Sheets ˆ Color Elevations ˆ Design Matrix ˆ Plat Map ˆ Title Report ˆ Lot Closures ˆ Preliminary Civil Plans ˆ Archaeological Survey o Confidential Documents. Contact the City to obtain. ˆ Topography (Existing Conditions) ˆ CC&R’s ˆ Deeds / Easements / Conveyances /Dedications ˆ Developer’s Agreement ˆ Recorded Copies ˆ Bonding or Assignment of Funds o Confidential Documents. Contact the City to obtain. ˆ Letters and Project Documents ˆ Other: Civil ˆ Issued Permit ˆ Application ˆ Other Applications ˆ Construction Calculation Worksheet ˆ Approved Plans ˆ Review Comment Form ˆ Letters and Project Documents ˆ Other Agency Permits ˆ Reports: o Drainage Report Pg: o Stormwater Pg: o Geotech Pg: o All Other Reports ˆ SEPA and Noticing Materials ˆ Inspections ˆ As-Builts ˆ Other: Building ˆ Issued Permit ˆ Application ˆ Additional Applications ˆ Approved Plans ˆ Site Plan ˆ Letters and Project Documents ˆ Calculations ˆ Project Specification Manuals ˆ Reports ˆ Certificate of Occupancy ˆ Inspections ˆ Other: BLD1992 Commercial Mechanical 17202 Smokey Point Blvd December 2018 ✔ ✔ ✔ ✔ ✔ 45,000 17020 S MOKEY POINT BLVD 00482800000104 S MOKEY POINT PROPERTY LLC 111-111-1111 PO BOX 528 MEDINA WA 98039 1234@S MOKEYPOINTLLC.COM 425-821-1293 PO BOX 3205 KIRKLAND WA 98083 JEREMY@CFM-HVACR.COM CFM HEATING AND COOLING 425-821-1293 PO BOX 3205 KIRKLAND WA 98083 S AME AS CONTACT CFMHEHC969CD 2 2 INS TALL 2 NEW ROOFTOP AC U NITS JEREMY MOELLER 02/28/2020 ✔ JEREMY MOELLER Jeremy Moeller 05/30/2018 A. CRITERIA 1.DESIGNED USING 2015 INTERNATIONAL BUILDING CODE (IBC) 2.RISK CATEGORY TYPE (IBC TABLE 1604.5) = II B. ROOF LOADS 1.GROUND SNOW LOAD = 25 PSF 2.ROOF SNOW/LIVE LOAD = 25 PSF 3.ROOF DEAD LOAD = 20 PSF 4.ROOF DEFLECTIONS TL = L/180 5.ROOF DEFLECTIONS LL = L/240 C. SEISMIC LOADS 1.MAPPED SPECTRAL RESPONSE ACC. FOR SHORT PERIOD, SS = 1.089 G 2.MAPPED SPECTRAL RESPONSE ACC. FOR 1-SEC PERIOD, S1 = 0.425 G 3.DESIGN SPECTRAL RESPONSE ACC. COEFF. AT SHORT PERIOD, SDS = 0.773 G 4.DESIGN SPECTRAL RESPONSE ACC. COEFF. AT 1-SEC PERIOD, SD1 = 0.446 G 5.BUILDING SITE CLASS (IBC TABLE 1613.5.2)= D 6.SEISMIC DESIGN CATEGORY (IBC TABLE 1613.5.6(1 & 2))= D 7.SITE COEFFICIENT, FA (IBC TABLE 1613.5.3(1))= 1.064 8.SITE COEFFICIENT, FV (IBC TABLE 1613.5.3(1))= 1.575 9.SEISMIC IMPORTANCE FACTOR, IE = 1.00 10.RESPONSE MODIFICATION FACTOR, R = 6.5 (RTU) 11.ANALYSIS PROCEDURE USED = EQUIVALENT LATERAL FORCE PROCEDURE D. WIND LOADS 1. WIND IMPORTANCE FACTOR, IW = 1.00 2. BASIC WIND SPEED (3-SECOND GUST)= 110 MPH 4.DESIGN WIND PRESSURE (RTU)= 47.8 PSF 3. WIND EXPOSURE = C A. ALL STEEL CONSTRUCTION SHALL CONFORM TO REQUIREMENTS SET FORTH IN THE LATEST EDITIONS OF AISC, " AMERICAN INSTITUTE OF STEEL CONSTRUCTION", AISC 341-10, " SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS, INCLUDING SUPPLEMENT NO 1, DATED 2010" AND AISC 360-10, "SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS". B. STEEL DESIGNATIONS: 1. WIDE FLANGE SHAPES (BEAMS & COLUMNS)= ASTM A992 (GRADE 50) 2. OTHER ROLLED SHAPES & PLATE = ASTM A36 (U.N.O.) PIPE 3. COLUMNS = ASTM A53, GRADE 'B' 4. STRUCTURAL HSS TUBING = ASTM A500, GRADE 'B' 46 KSI C. ALL ANCHOR BOLTS, BOLTS AND LAGS IN WOOD SHALL CONFORM TO ASTM A307 STEEL U.N.O. AND SHALL HAVE STEEL WASHERS BENEATH ALL NUTS AND BOLT HEADS. IF A CERTAIN SITUATION IS NOT DETAILED USE A SIMILAR DETAIL. ALL STRUCTURAL BOLTS SHALL CONFORM TO ASTM A325-N. CONNECTIONS SHALL GENERALLY FOLLOW THE TYPES SHOWN IN AISC MANUAL OF STEEL CONSTRUCTION. D. STEEL FABRICATOR SHALL ALSO INCLUDE AND COORDINATE ALL STRUCTURAL STEEL SHOWN ON ARCHITECTURAL SHEETS WITH THAT OF THE STRUCTURAL SHEETS, COORDINATE ANY STEEL NOT SHOWN ON STRUCTURAL DRAWINGS, CONTRACTOR TO VERIFY. E. ALL BEAMS ELEVATIONS FOR JOISTS, BEAMS, AND COLUMN HEIGHTS SHALL BE COORDINATED AND VERIFIED BY THE CONTRACTOR. cw/ ARCH. ALL ELEVATIONS MUST BE APPROVED BY ENGINEER AND ARCHITECT OF RECORD IN THE SHOP DRAWING REVIEW PROCESS. F. ALL STEEL WELDING SHALL CONFORM TO AWS D1.1 WITH E70XX ELECTRODES. G. PROVIDE HIGH STRENGTH GROUT UNDER ALL STEEL BASE PLATES, F'c = 5,000 PSI, MIN. A. ALL WELDS ON MEMBERS COMPRISING THE SEISMIC-FORCE-RESISTING SYSTEM (MOMENT AND BRACE FRAMES) SHALL EMPLOY WELD FILLER METALS CLASSIFIED FOR NOMINAL 70 KSI TENSILE STRENGTH, REFERRED TO AS E70 ELECTRODES, MEETING THE FOLLOWING MINIMUM MECHANICAL PROPERTY REQUIREMENTS: 1. CVN TOUGHNESS OF 20 FT-LB AT 0°F, USING AWS A5 CLASSIFICATION TEST METHODS. 2. CVN TOUGHNESS OF 40 FT-LB AT 70°F, USING THE TEST PROCEDURES PRESCRIBED IN APPENDIX A. 3. YIELD STRENGTH: 58 KSI MINIMUM, USING BOTH THE AWS A5 CLASSIFICATION TEST (FOR E70 CLASSIFICATION ELECTRODES) AND THE TEST PROCEDURES PRESCRIBED IN APPENDIX A. 4. TENSILE STRENGTH: 70 KSI MINIMUM, USING BOTH THE AWS A5 CLASSIFICATION TEST ( FOR E70 CLASSIFICATION ELECTRODES" AND THE TEST PROCEDURES PRESCRIBED IN APPENDIX A. 5. ELONGATION: 22% MINIMUM, USING BOTH THE AWS A5 CLASSIFICATION TEST AND THE TEST PROCEDURES PRESCRIBED IN APPENDIX A. A. ALL ELEVATIONS AND HEIGHTS GIVEN ARE FROM THE FINISHED FLOOR DATUM ELEVATION, WHICH IS SET AT 100'-0". B. DO NOT SCALE DRAWINGS, CONTACT A.O.R. OR E.O.R. FOR DIMENSION CLARIFICATIONS PRIOR TO CONSTRUCTION. C. VERIFY ALL OPENINGS, BUILDING DIMENSIONS, COLUMN GRID LOCATIONS AND DIMENSIONS WITH OWNER PRIOR TO POURING OF ANY CONCRETE FOUNDATIONS OR CONSTRUCTION. D. THE ENGINEER OF RECORD IS NOT RESPONSIBLE FOR ANY DEVIATIONS FROM THESE PLANS UNLESS SUCH CHANGES ARE AUTHORIZED IN WRITING TO THE STRUCTURAL ENGINEER OF RECORD. E. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING SAFE AND ADEQUATE SHORING AND/OR TEMPORARY STRUCTURAL STABILITY FOR ALL PARTS OF THE STRUCTURE DURING CONSTRUCTION. THE STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR FINAL CONFIGURATION. F. NOTCHING AND/OR CUTTING OF ANY STRUCTURAL MEMBER IN THE FIELD IS PROHIBITED, UNLESS PRIOR CONSENT IS GIVEN BY THE STRUCTURAL ENGINEER OF RECORD. G. IT IS NECESSARY THAT THE STRUCTURAL DRAWINGS BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS TO HAVE A COMPLETE SCOPE OF WORK INVOLVED IN THIS PROJECT. A. PER IBC SECTION 1709, STRUCTURAL OBSERVATIONS SHALL BE PERFORMED BY A REPRESENTATIVE FROM THE ENGINEER OF RECORD'S OFFICE (TAMARACK GROVE ENGINEERING, PLLC) OR AN APPOINTED REPRESENTATIVE TO PERFORM ON-SITE STRUCTURAL OBSERVATION VISITS DURING SIGNIFICANT TIMES OF CONSTRUCTION-RELATED TO OUR DEFERRED SUBMITTAL SCOPE OF WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL SIGNIFICANT TIMES OF CONSTRUCTION WITH THE ENGINEER OF RECORD'S OFFICE PRIOR TO THE COMPLETION POINT REQUIRING SITE OBSERVATIONS FOR THE CONSTRUCTION AND/OR PLACEMENT (MINIMUM OF 4 CALENDAR DAYS). SIGNIFICANT TIMES OF CONSTRUCTION ARE AS FOLLOWS: 1. CONCRETE FOUNDATION AND REBAR PLACEMENT. 2. PLACEMENT OF PERIMETER LOAD BEARING WALLS, LOAD SUPPORTING BEAMS, FLOOR FRAMING AND/OR HEADERS AND LATERAL RESISTING CONNECTION ELEMENTS. 3. COMPLETION OF ROOF FRAMING AND LATERAL BRACING (SHEAR WALLS), PRIOR TO COVERING WITH ANY ARCHITECTURAL FINISHES. 4. COMPLETION OF ALL STRUCTURAL SYSTEMS AS REQUIRED AND/OR DEFINED BY THE LOCAL JURISDICTION. B. STRUCTURAL OBSERVATIONS DO NOT INCLUDE OR WAIVE THE RESPONSIBILITY FOR THE SPECIAL INSPECTIONS REQUIRED BY THE IBC SECTION 1704 OR OTHER SECTIONS OF THE CODE AS REQUIRED BY THE LOCAL BUILDING JURISDICTION. C. STRUCTURAL OBSERVATIONS REQUIRED IN OBSERVANCE OF SECTION 1704 OR PER LOCAL JURISDICTION. A. CONTRACTOR SHALL VERIFY ANY AND ALL APPLICABLE EXISTING CONDITIONS, CONSTRUCTION, DIMENSIONS AND ELEVATIONS AND IMMEDIATELY NOTIFY ARCH. AND EOR OF ANY DISCREPANCIES BEFORE PROCEEDING WITH ANY CONSTRUCTION. A. AS REQUIRED BY THE LOCAL JURISDICTION. ABBREVIATIONS LC INCH INSULATION INTERIOR JOINT KNOCKOUT CENTERLINE DIAMETER OR ROUND RENOVATE NEW FUTURE EXISTING HEATING VENTILATING AND AIR CONDITIONING LINEAL FEET OR FOOT LAMINATE LOW POINT MACHINE BOLT POUNDS MANHOLE SQUARE MECHANICAL MAXIMUM METAL MANUFACTURER MISCELLANEOUS MINIMUM BOTTOM OF BETWEEN BOTTOM OF CONCRETE ARCHITECTURAL ALTERNATIVE ADJUSTABLE ALUMINUM AGGREGATE ABOVE APPROXIMATE NUMBER OR POUND AT ANCHOR BOLT ABOVE FINISH FLOOR NOT IN CONTRACT MATERIAL NORTH NOT TO SCALE NUMBER NOMINAL NEAR SIDE OVER OVER ALL OVERHEAD OUTSIDE DIAMETER OPPOSITE HAND OPENING ON CENTER NEAR SIDE BOTTOM COLUMN CONCRETE OPENING CONCRETE MASONRY UNIT CAST IRON CAST IN PLACE CENTER TO CENTER CLEAR COUNTERSUNK CEILING BEAM BLOCK BUILDING BOARD BUILT-UP MOUNTED LAMINATED VENEER LUMBER LONG LEG VERTICAL LONG LEG HORIZONTAL MASONRY OPENING PERPENDICULAR PROPERTY LINE PARTICLE OPPOSITE OUNCE POINT PLATE PLYWOOD RADIUS OR RISER ROOF DRAIN REINFORCE(D) REQUIRED ROUGH OPENING CORRIDOR ECCENTRICALLY BRACED FRAME EACH DRAWING DOWN DIMENSION EXPANSION JOINT EXPANSION BOLT DEFORMED BAR ANCHOR DETAIL DEEP DIAGONAL DIAMETER COORDINATE WITH CONTINUOUS STAINLESS STEEL SOLID CORE SECTION SHEET SCHEDULE STRUCTURAL SQUARE STANDARD SYMMETRICAL TOP OF BEAM SUSPENDED SPECIFICATIONS FACE OF MASONRY FACE OF TREAD FACE OF STUDS ELEVATOR FACE OF CURB/CONCRETE FACE OF FLAT BAR EXTERIOR EXPANSION EQUIPMENT FACE OF FINISH FLOOR DRAIN EQUAL ELECTRICAL ELEVATION ROOM SQUARE FEET OR FOOT REFERENCE (CW/) TONGUE & GROOVE SIMILAR OR SIMILAR TO PRE-ENGINEERED METAL BUILDING PARALLEL STRAND LUMBER TOP OF DECK TOP OF SLAB TOP OF MASONRY TYPICAL THICKNESS TOP OF WALL VERIFY IN FIELD VERTICAL WITHOUT WIDE WOOD WITH HIGH HEADED CONCRETE ANCHOR HORIZONTAL HIGH POINT GALVANIZED FURRING GAUGE OR GAGE FIRE TREATED WOOD GYPSUM FLOOR(ING) FOOTING FLASHING FINISH FAR SIDE FOOT OR FEET WORK POINT HEIGHT INSIDE DIAMETER HOUR WELDED WIRE FABRIC UNLESS OTHERWISE NOTED UNLESS NOTED OTHERWISE UNIFORM BUILDING CODE FOUNDATION TOP OF CURB/CONCRETE CONCRETE PART. CORR. U.B.C. U.N.O. U.O.N. P.S.L. PRE-ENG. W/ H. HR. HT. I.D. H.C.A. HORIZ. H.P. W.W.F. WD. W.P. W. W/O F.O.M. GALV. FURR. GA. FTW. GYP. FL. FTG. FLASH. FDN. FIN. F.S. FT. F.O.T. F.O.S. ELEV. F.O.C. F.O. F.B. EXT. EXP. EQUIP. F.O.F. F.D. EQ. E.B.E. ELEC. EL. EA. DWG. DN. DIM. E.J. E.B D.B.A. DET. D. DIAG. DIA. CW/ SIM. T.O.M. T.O.S. V.I.F. TYP. THK. T.O.W. VERT. SYM. T&G T.O.C. T.O.D. T.O.B. SUSP. STRUC. STD. SQ. SPECS. RE: S.F. S.S. S.C. RM. REQ'D. REINF. SHT. SECT. SCHED. PLYWD. PL. P/L R.O. R.D. R. PT. HVAC LVL BOT. COL. CONT. CONC. C.O. CMU C.I. C.I.P. C.C. CLR. CNTRSK. CLG. # B.O. B/T BM. BLK. BLDG. BD. B.U. B.O.C. ARCH. @ ALT. ADJ. ALUM. AGG. ABV. APPROX. A.F.F. A.B. (R) (N) (F) (E) MIN. N.S. O.A. O/ O/H OZ. OPP. OPNG. O.H. O.D. O.C. NOM. NO. MISC. N.T.S. N.I.C. N MTRL N.S. MT'D L.P. LAM. MFR. MET. MECH. MAX. M.O. M.H. M.B. LBS. L.F. K.O. JT. INT. INSUL. IN. L.L.H. L.L.V. TRUSS JOIST I-JOISTTJI EDGE NAIL(ING)E.N. DOUGLAS FIRD.F. BOUNDARY NAIL(ING)B.N. LAMINATED STRAND LUMBERLSL ∅ □ T HOLLOW STRUCTURAL STEELH.S.S. GENERAL STRUCTURAL NOTESGSN ENGINEER OF RECORDEOR EDGE SCREWES. TGE fax web The drawings and plans set forth on this set as instrument of service are, and shall remain, the property of Tamarack Grove Engineering. Use of this drawing is limited to a specified project for persons named hereon. Any use or reuse of said drawings is strictly prohibited without written permission of Tamarack Grove Engineering. sheet title: symbol revision date 812 S. La Cassia Drive Boise, ID 83705 (208) 345-8941 (208) 345-8946 www.tamarackgrove.com FIRM NO. 603490470 Drawn By: Dwg Date: Checked By: Job No: firm GENERAL STRUCTURAL NOTES 17020 SMOKEY POINT BLVD. ARLINGTON, WA 98223 SMOKEY POINT HABITAT FOR HUMANITY S1.0 DDH AJB 4-24-18 TGE18-10181 1 DESIGN CRITERIA 2 STRUCTURAL STEEL 3 STRUCTURAL WELDS 4 GENERAL STRUCTURAL NOTES 5 STRUCTURAL OBSERVATIONS 6 EXISTING CONDITIONS 7 SPECIAL INSPECTIONS AND TESTING SHEET LIST SHEET NUMBER SHEET NAME S1.0 GENERAL STRUCTURAL NOTES S2.0 PARTIAL ROOF FRAMING PLAN S3.0 STRUCTURAL DETAILS 18 04/24/18 UP (E ) O W S J @ 6 ' -0" O . C . (G . C . T O V E R I F Y ) , T Y P . WEB STIFFENERS @ ANGLE BLOCKING BEARING LOCATIONS, TYP., RE: /5 S3.0 (E) COLUMN TO REMAIN, TYP. (E ) J O I S T G I R D E R (G . C . T O V E R I F Y ) (E ) J O I S T G I R D E R (G . C . T O V E R I F Y ) (E ) J O I S T G I R D E R (G . C . T O V E R I F Y ) (E ) J O I S T G I R D E R (G . C . T O V E R I F Y ) (E ) J O I S T G I R D E R (G . C . T O V E R I F Y ) (E ) J O I S T G I R D E R (G . C . T O V E R I F Y ) (E ) J O I S T G I R D E R (G . C . T O V E R I F Y ) (E ) J O I S T G I R D E R (G . C . T O V E R I F Y ) (E ) J O I S T G I R D E R (G . C . T O V E R I F Y ) (E ) J O I S T G I R D E R (G . C . T O V E R I F Y ) (E ) J O I S T G I R D E R (G . C . T O V E R I F Y ) (E ) J O I S T G I R D E R (G . C . T O V E R I F Y ) (E ) J O I S T G I R D E R (G . C . T O V E R I F Y ) (E ) J O I S T G I R D E R (G . C . T O V E R I F Y ) (E ) J O I S T G I R D E R (G . C . T O V E R I F Y ) (E ) J O I S T G I R D E R (G . C . T O V E R I F Y ) (E ) J O I S T G I R D E R (G . C . T O V E R I F Y ) (E ) J O I S T G I R D E R (G . C . T O V E R I F Y ) (N) RTU #3 WEIGHING APPROX.=1,450 lbs., w/ (N) L4x4x1/4 MECHANICAL UNIT SUPPORT FRAMING, TYP., RE: FOR ROOF DECK SUPPORT FRAMING AT OPENINGS, RE: FOR CURB ATTACHEMENT, RE: /1 S3.0 (N) RTU #3 WEIGHING APPROX.=1,450 lbs., w/ (N) L4x4x1/4 MECHANICAL UNIT SUPPORT FRAMING, TYP., RE: FOR ROOF DECK SUPPORT FRAMING AT OPENINGS, RE: FOR CURB ATTACHEMENT, RE: /1 S3.0 /3 S3.0 /3 S3.0 /4 S3.0 /4 S3.0 WEB STIFFENERS @ ANGLE BLOCKING BEARING LOCATIONS, TYP., RE: /5 S3.0 G.C. TO VERIFY 55' - 7 7/8" G.C. TO VERIFY 46' - 8" G.C. TO VERIFY 30' - 1 3/4" G.C. TO VERIFY 24' - 0" G.C. TO VERIFY 29' - 7 1/4" G. C . T O V E R I F Y 20 ' - 1 0 1 / 4 " G. C . T O V E R I F Y 40 ' - 2 1 / 4 " G. C . T O V E R I F Y 40 ' - 8 1 / 4 " G. C . T O V E R I F Y 31 ' - 5 3 / 8 " G. C . T O V E R I F Y 71 ' - 9 " TGE fax web The drawings and plans set forth on this set as instrument of service are, and shall remain, the property of Tamarack Grove Engineering. Use of this drawing is limited to a specified project for persons named hereon. Any use or reuse of said drawings is strictly prohibited without written permission of Tamarack Grove Engineering. sheet title: symbol revision date 812 S. La Cassia Drive Boise, ID 83705 (208) 345-8941 (208) 345-8946 www.tamarackgrove.com FIRM NO. 603490470 Drawn By: Dwg Date: Checked By: Job No: firm PARTIAL ROOF FRAMING PLAN 17020 SMOKEY POINT BLVD. ARLINGTON, WA 98223 SMOKEY POINT HABITAT FOR HUMANITY S2.0 DDH AJB 4-24-18 TGE18-10181 N SHEET NOTES: ·REFER TO GENERAL STRUCTURAL NOTES ON SHEET S1.0 FOR ADDITIONAL INFORMATION. ·REFER TO MECHANICAL PLANS FOR EXACT LOCATIONS OF ALL MECHANICAL UNITS. ·COORDINATE LOCATION OF ALL RTU'S WITH MECHANICAL E.O.R. SO THAT THE OPENINGS DO NOT INTERFERE WITH (E) FRAMING. ·G.C. TO VERIFY JOIST SIZE AND SPACING. IT IS THE G.C.'S RESPONSIBILITY TO NOTIFY THE EOR OF ANY DISCREPANCY IN THE MEMBER SIZES NOTED IN PLANS. ·G.C. TO VERIFY COLUMN LOCATIONS AND SIZES, TYP. 3/32" = 1'-0"1 PARTIAL ROOF FRAMING PLAN 18 04/24/18 2A S3.0 2B S3.0 (E) ROOF JOIST OR GIRDER (N) L4x4x1/4 PERIMETER ROOF TOP UNIT SUPPORT BLOCKING, TYP., CENTERED ON UNIT CURB, TYP. CENTERLINE OF MECHANICAL UNIT CURB FOR DECK SUPPORT FRAMING AT MECHANICAL OPENINGS LARGER THAN 12" DIA. OR 12"x12" SQ., RE: FOR MECHANICAL OPINING LOCATIONS, RE: MECHANICAL /3 S3.0 3/16 TYP. PERIMETER ROOF TOP UNIT BLOCKING (E) ROOF DECK (E) ROOF JOIST OR GIRDER, TYP. NOTE: FOR JOIST WEB STIFFENERS AS REQUIRED FOR UNITS INDICATED ON PLANS, RE: (NOT SHOWN FOR CLARITY)/5 S3.0 COPE (N) ANGLE @ EACH END TO ENSURE FULL LENGTH WELDS @ (E) JOIST 3/16 TYP. PERIMETER ROOF TOP UNIT BLOCKING (E) ROOF DECK GREATER THAN 6" (E)OPEN-WEB STEEL JOIST L2x2x1/4 FROM TOP LOAD POINT TO BOTTOM CHORD PANEL POINT, BOTH SIDESTO P C H O R D LO A D P O I N T 1/4TYP. NOTE: TYPICAL STEEL JOIST REINFORCING WHERE CONCENTRATED LOADS EXCEED 100LBS BETWEEN PANEL POINTS . HANGING THE LOAD IF NOT AT BOTTOM CHORD PANEL POINT L2x2x1/4 FROM BOTTOM LOAD POINT TO TOP CHORD PANEL POINT, BOTH SIDES BOTTOM CHORD LOAD POINT PRE-FABRICATED CURB FASTEN TO STRUCTURE w/ #10 SCREWS @ 12" O.C. OR 1/2" DIA.x6" LONG LAG SCREW @ EA. CORNER DECKING ROOFING BLOCKING COUNTER FLASHING FASTEN EQUIPMENT BASE TO PRE-FABRICATED CURB w/ #10 TEK SCREWS @ 12" O.C. WOOD NAILER 1/4" NEOPRENE FOAM GASKET ROOF TOP UNIT 2A S3.0 2B S3.0 (E) ROOF JOIST OR GIRDER NOTE: REFER TO ARCHITECTUAL AND MECHANICAL DRAWINGS FOR NUMBER SIZE AND LOCATION OF ROOF OPENINGS, PROVIDE STEEL FRAME FOR ALL OPENIGS LARGER THAN 12" DIA. OR 12"x12" SQ. (N) L2 1/2x2 1/2x3/16 DECK SUPPORT FRAMING, TYP. SIM. SIM. TGE fax web The drawings and plans set forth on this set as instrument of service are, and shall remain, the property of Tamarack Grove Engineering. Use of this drawing is limited to a specified project for persons named hereon. Any use or reuse of said drawings is strictly prohibited without written permission of Tamarack Grove Engineering. sheet title: symbol revision date 812 S. La Cassia Drive Boise, ID 83705 (208) 345-8941 (208) 345-8946 www.tamarackgrove.com FIRM NO. 603490470 Drawn By: Dwg Date: Checked By: Job No: firm STRUCTURAL DETAILS 17020 SMOKEY POINT BLVD. ARLINGTON, WA 98223 SMOKEY POINT HABITAT FOR HUMANITY S3.0 DDH AJB 4-24-18 TGE18-10181 1" = 1'-0"1 MECHANICAL UNIT/CURB SUPPORT FRAMING 1" = 1'-0"2A UNIT/CURB SUPPORT FRAMING SECTION 1" = 1'-0"2B UNIT/CURB SUPPORT FRAMING SECTION 1" = 1'-0"5 JOIST WEB STIFFENERS 1 1/2" = 1'-0"4 EQUIPIMENT TO CURB DETAIL (STEEL) 1" = 1'-0"3 ROOF DECK SUPPORT FRAMING 18 04/24/18