Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3704 172ND ST NE_PA25-0082_2026
18204 59th Avenue NE • ' • 14 op Arlington, Washington 98223 to tt Phone: 360-403-3551 jNG� WASHINGTON C Sign - Sign Installation Permit Parcel:31052800201301 Permit#:25-0082 Permit Address:3704 172ND ST NE Date Issued:January 26,2026 Description of Work:New wall sign installation PERMIT EXPIRES 180 DAYS Valuation:$835.00 AFTER DATE OF ISSUANCE. Code Year: OWNER APPLICANT CONTRACTOR Northwest Sign&Design Northwest Sign&Design NORTHGATE STATION 17201 Beaton Rd SE PO BOX 6770 KETCHUM,ID,83340 172014-6415 ext.35 425-844-6415 ext.35 permits -6415 ext. 35 permits@nwsigns.com registration_number:602 156 837 PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. It is unlawful to use or occupy a building or structure until a final inspection has been made and approval or a Certificate of Occupancy has been granted. This permit authorizes only the work noted and covers work to be done on private property only. Any construction on public domain (curbs, sidewalks, driveways, marquees, etc.) will require a separate permit. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. CONDITIONS 1.) Attachment fasteners shall be inspected at time of installation (wall signs only) 2 ) Attachment to stucco, EIFS or dryvit type substrate will require sleeve details for each fastener used for said attachment 3.) Approved job copy shall be onsite for inspections. 4.) Adhere to approved plans 5.) Call for inspections. INSPECTIONS Inspection Line: 360-403-3417 Call for inspections by 3:30 pm for next day inspection. Please allow 48 hours for Fire Inspections. Please provide the following information when leaving a message: Permit Number, Type of Inspection, and provide preference of morning or afternoon inspection. Inspection Portal: Please login to customer portal and submit for the desired inspection type for the permit. Kevin Olander Building Official ASSOCIATED FEES Date Description Paid Date Amount Paid Balance December 1, Processing/Technology(320.341.43.00.02) $25.00 2025 December 1, Building Permit(006.322.10.00.01) $49.31 2025 December 1, Building Plan Review(006.345.83.00.02) $52.28 2025 TOTAL: Permit Fees $126.59 $126.59 Credit/Debit Card 238 Payment Successful January 26, 2026 $126.59 $0.00 i SIGN PERMIT APPLICATION ` Community and Economic Development City of Arlington- 18204 59th Ave NE-Arlington,WA 98223 - Phone(360) 403-3551 This application is for new, refaced, modification of existing sign, or removal of sign(s). If your building or development has a Master Sign Program,please use the Master Sign Application. ELECTRONIC FILES SUBMITTAL REQURIEMENTS: ❑STRUCTURAL CALCULATIONS (where applicable) 0 COMPLETE PLANS F1 SITE PLAN -All existing and proposed signs need to be shown on the site plan. MULTI-TENANT: ZI Is the building occupied by more than one tenant? 0 Yes ❑No ❑Number of tenants and/or available business spaces on property: ❑Is there a City-approved Master Signage Plan for the building?If so,what is the file number: IF A TENANT OR LESSEE: a letter from the property owner or Lease Agreement stating the following: ❑Permission for sign installation. IF HANGING,CANOPY,MARQUEE OR PROJECTING SIGNS OVER PUBLIC RIGHT-OF-WAY: ❑Distance from curb. ❑Measurement from grade to bottom of the sign. ❑Right-of-Way Hold Harmless Agreement. ❑Right-of-Way Use Permit. Type of Permit: 0 New Sign ❑ Modification of Existing Sign ❑ Sign Removal Type of Sign: 0 Wall Sign ❑ Window Sign ❑ Freestanding Sign ❑ Hanging Sign ❑ Marquee Sign ❑ Canopy Sign ❑ Projecting Sign Illumination: ❑ No Illumination 0 Interior Illumination ❑ External Illumination ❑ Readerboard Property Address: 3704 172nd St. NE Suite Number: Project Valuation: $3127.00 Preferred Contact: ❑ Owner 0 Contractor Scope of Work: Installation of QTY:1 Sign that reads Defensive Driving School with a small car logo.The sign is illuminated and being installed on the wall over the main entrance of a single story building. Business Name: Defensive Driving School Business Phone No.: 425-315-5436 Owner/Applicant Name: Jason Pierce Phone No.: 425-315-5436 Email Address: shiskibob@gmail.com Cell No.: Mailing Address: 3704 172nd ST NE STE I City:Arlington State: WA Zip: 98223 Contractor Name: Northwest Sign & Design Office No.: 425-844-6415 ext. 35 Email Address: permits@nwsigns.com Cell No.: N/A Mailing Address: 17201 Beaton RD SE City. Monroe State: WA Zip: 98272 L&I Contractor License Number: NWSIGS*84201 Expiration Date: 10/7/2026 REV2022 Page 1 of 3 BUILDING INFORMATION Zoning Designation: CITY Zoning Overlay Designation: 539 Other Retail Trade NEC Building Total Length: 907.86 Building Total Square Footage: 111,421 Total Number of Suites: 20 How many floors contain Suites for lease: 1 Is the development located on a corner lot? ❑ Yes 0 No Is the development located on a lot that is bordered by two public streets? ❑ Yes 0 No If yes, do the streets intersect at the lot's boundaries? ❑ Yes 0 No EXISTING SIGNS ASSOCIATED WITH THE BUSINESS WALL(W), CANOPY(C), HANGING(H), MARQUEE(M), PROJECTING(P) OR FREESTANDING(F) Suite# Type Facade Height x Width - Square Company Removal of Sign (N,S,E,W) Footage Name x = ❑Yes ❑No x = ❑Yes El No x = ❑Yes El No x = El Yes El No x = ❑Yes El No EXISTING SIGNS ON-SITE: Exclude Proposed Signs WALL(W), CANOPY(C), HANGING(H), MARQUEE(M), PROJECTING(P) OR FREESTANDING(F) Suite# Type Facade Height x Width - Square Company Removal of Sign (N,S,E,W) Footage Name x = ❑Yes ❑No x = ❑Yes ❑No x = ❑Yes ❑No x = ❑Yes ❑No x = ❑Yes ❑No x = ❑Yes ❑No x = ❑Yes ❑No x = ❑Yes ❑No x = ❑Yes ❑No x = ❑Yes ❑No x = ❑Yes ❑No x = ❑Yes ❑No Total Square Footage of Existing Signage: Total#Removed: REV2022 Page 2 of 3 PROPOSED SIGNS WALL(W), CANOPY(C), HANGING(H), MARQUEE(M), PROJECTING(P) OR FREESTANDING(F) Suite# Type Facade Height x Width = Square Company Replacement of Sin N,S,E,W Footage Name I W N 3' 2 3/4" x 9" 6" = 29.77 Defensive Driving School ❑Yes ONo x = ❑Yes ❑No x = ❑Yes ❑No x = ❑Yes ❑No x = ❑Yes ❑No Total Square Footage of Proposed Signage: 29.77 Total#Replaced: FREESTANDING SIGN ❑ Two-Sided ❑ Two-Sided"V" ❑ Multi-Sided ❑ Three Dimensional What is the length of public street frontage adjacent to the development? x 0.3= Sign Face (north,south,east,west) Height x Width x Length = Square Footage 1. x x = 2. x x = 3. x x = Total Square Footage: See Assistance Bulletin#34 for additional information on calculating allowed square footage of signs. Standard Calculation for single business sign allowance: First floor square footage(so of the space the business occupies: 111,421 x 0.025 = 2,785.52 Total sf allowed. Alternate Calculation for single business sign allowance: Lineal feet of the frontage space the business occupies: x 1.5= Total sf allowed. Freestanding Sign Calculation Length of public street frontage adjacent to the development: x 0.3 = Total sf allowed per side. Length of public street frontage adjacent to the development: x 0.75 = Total sf allowed per side Highway Commercial Zone Only. 1 hereby certify that 1 am the ❑ Owner, ✓❑ Contractor and authorized to sign this application and that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be accordance with the laws, rules and regulations of the State of Washington and the City ofArlington. Digitally signed Adrie Ad ri e l Blake Date:2025.11 25 15:22 I341ake 08'00' Ad ri e l Blake 11/25/2025 Signature Print Name Date REV2022 SAVE PRINT Page 3 of 3 11/25/2025 Erin Perry Azose Commercial Properties 8451 SE 68' St Mercer Island,WA 98040 Re:Approval of Signage Design for Defensive Driving at 3704 172nd ST, STE I,Arlington WA To whom it may concern, I, Erin Perry, on behalf of Northgate Station LP, hereby confirm my relation to the tenant as Property Manager. I manage the space located at 3704 172nd St,Arlington WA where the proposed signage is to be installed. I have reviewed the attached production drawings for the signage design(s) provided by Northwest Sign & Design. I hereby approve the designs as presented and confirm that they meet all requirements as established in the lease agreement and design criteria as established in the design standards set forth bythe property owner.All submittals are subject to compliance with all applicable local codes and regulations. If there are any questions or additional information required, please contact me at 206- 608-0521 or eperry@azose.com. Sincerely, Erin Perry Property Manager 11/25/2025 Erin Perry Azose Commercial Properties 8451 SE 68' St Mercer Island,WA 98040 Re:Approval of Signage Design for Defensive Driving at 3704 172nd ST, STE I,Arlington WA To whom it may concern, I, Erin Perry, on behalf of Northgate Station LP, hereby confirm my relation to the tenant as Property Manager. I manage the space located at 3704 172nd St,Arlington WA where the proposed signage is to be installed. I have reviewed the attached production drawings for the signage design(s) provided by Northwest Sign & Design. I hereby approve the designs as presented and confirm that they meet all requirements as established in the lease agreement and design criteria as established in the design standards set forth bythe property owner.All submittals are subject to compliance with all applicable local codes and regulations. If there are any questions or additional information required, please contact me at 206- 608-0521 or eperry@azose.com. Sincerely, Erin Perry Property Manager SIGNAGE OVERVIEW - NOT TO SCALE m3m PROJECT PAGE I of 3 PROJECT: Def.Driv.School Install-Arlington CLIENT: I Defensive Driving School CONTACT: Jason Pierce INSTALL ADDRESS: 3704172nd St.NE,Ste I Arlington,WA 98223 PROJECT MANAGER: Gabe Stoddard SALES: Shawn Hamilton DRIVING SCHOOL ���` DESIGNER: N/A PRODUCTION DESIGNER: • Michael Wells �• DATE: 08/27/25 REVISIONS MW Permit 08/27/25 COLORS/FINISHES ST-02 MP to Match Beam?? FINAL FOR PRODUCTION NOTES/OTHER File Name: Def_Driving_Arlington_S08361_PermitPack 1 Survey& installation of sign(multiple components)from another location + Painting raceway I I 1 RELEASE FOR PRODUCTION NORTHWEST SIGN & DESIGN PROJECT MANAGER: 172o1 Beaton Rd.SE Monroe,WA 98272 vciww.NWSigns.com (425)844-6415 CLIENTAPPROVAL APPROVED AS-IS ❑ APPROVED With Changes ❑ Please carefully review all contents contained herein.Your signature indicates approval of all 0 2023 NW Sign&Design,all rights reserved.These drawings are the property solely of NW Sign&Design and are not to be used or Contractors Lic#NWWHOS'929M9 stakeholders for materials,design,colors,spelling,sizes,and fabrication and installation methods reproduced in any manner without prior written permission.Penalties of$5,000 will be charged for each page of this drawing set and/or • including responsibility for errors and omissions.The client will hold Northwest Sign&Design harmless each instance of product designs that are displayed and/or produced with unlawfully used artwork. ELECTRIC SIGNS PRODUCED AT NW SIGNS and will be responsible for compensation for changes or corrections made after approval No work will U` CONFORM TO UL48 AND DISPLAYTHE SIGN: DATE: be started without signed approval or an appropriate waiver from the client. o UNDERWRITERS LABORATORIES LABEL. EMM PRODUCTION 9'-6" PACK PAGE 2 of 3 ----------- - 1 , II— ----Sign Area:29.77 sq/ft SCALE N/A U o ST 02 ILLUM. WALL SIGN - SURVEY CY) & INSTALL o DRS r Qty. 1 IN SC 00L] COLOR SUMMARY - 8`-2114M L�—Sn PAINT Q ��_� 3I4" MP TO MATCH BEAM?? SATIN FINISH Front View - Existing Sign Components - Sign is in internally illuminated by LEDs. f - Existing sign components(Channel letters on raceway+(2)channel clouds), rA ra) mounted to beam with 3/8"lag bolts+ #12 screws(see diagram below) HOME FURNISHING$ - Raceway to be paintedfj, to match beam at new location - Connected to existing power provided by others 1 Attachment Details N.T.S. _ INSTALL 1 DRIVING HOOL , PER UL-48 REQUIREMENTS: . THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE RECUIRETHE 3/8"lags NATIONAL ELECTRICAL ODELE AND OR // NATIONAL ELECTRICAL CODE AND/OR into wood structure INCLUDESPLICABLE PROPER GROUNDINOG AND HIS ' type OF THE SIGN. `7 6 S per raceway 2. THE LOCATION OF THE DISCONNECT SWITCH AFTER INSTALLATION SHALL / #12 SIDS screws k ,�; THE NACOMPL IONALEWITH ELECTRICAL CTRICALCODELE OF r � THE NATIONAL ELECTRICAL CODE. into wood structure CLIENT INITIAL/DATE: - ICI Proposed Install Location - No Scole NORTHWEST (� (� SIGN&DESIGN Center on Windows / Center Vertically on Facade NWSIgn Deslgn.all rights reserved. � SO#: 8361 SITE . , DEF.DRIVING SCHOOL ADDRESS: — - , 3704172nd St.NE,Ste 1 — - — Arlington,WA 98223 PARCEL: ' 3105280020130 -1'300 31052800201301 ♦ 3105280020130 31052800201303 31052800201304 ZONING: i Tzw sr K - row 3704 F2 Z 3701 G -, 3704 J 3704 L 3704 N 3704 K _ iL J 1 v ,�04 I< k 4W PS 1 I i CLIENT INITIAL/DATE: I 1 I NORTHWEST SIGN&DESIGN ©2023 NW Sign&Design.all rights reserved. � SO#: 8361 SITE . , DEF.DRIVING SCHOOL ADDRESS: — - , 3704172nd St.NE,Ste 1 — - — Arlington,WA 98223 PARCEL: ' 3105280020130 -1'300 31052800201301 ♦ 3105280020130 31052800201303 31052800201304 ZONING: i Tzw sr K - row 3704 F2 Z 3701 G -, 3704 J 3704 L 3704 N 3704 K _ iL J 1 v ,�04 I< k 4W PS 1 I i CLIENT INITIAL/DATE: I 1 I NORTHWEST SIGN&DESIGN ©2023 NW Sign&Design.all rights reserved. 11/25/2025 Jason Pierce Defensive Driving School 3704 172nd ST Suite I Arlington, WA 98223 United States of America Earth Sol System Milky Way Galaxy Local Group Virgo Supercluster Laniakea Supercluster Known Universe Re: Approval of Signage Design for Defensive Driving at 3704 172nd ST Suite I Arlington, WA To whom it may concern, 1, Jason Pierce, am the tenant at the space located at Defensive Driving School 3704 172nd ST Suite I Arlington,WA 98223 where the proposed signage is to be installed. I have reviewed the attached production drawings for the signage design(s) provided by Northwest Sign & Design. I hereby approve the designs as presented and authorize Northwest Sign & Design to install the signage in accordance with all applicable codes and regulations. If there are any questions or additional information required, please contact me at 425- 377-1837 or Jason@driving-school.com Sincerely, Co-Owner SIGNAGE OVERVIEW - NOT TO SCALE m3m PROJECT PAGE I of 3 PROJECT: Def.Driv.School Install-Arlington CLIENT: I Defensive Driving School CONTACT: Jason Pierce INSTALL ADDRESS: 3704172nd St.NE,Ste I Arlington,WA 98223 PROJECT MANAGER: Gabe Stoddard SALES: Shawn Hamilton DRIVING SCHOOL ���` DESIGNER: N/A PRODUCTION DESIGNER: • Michael Wells �• DATE: 08/27/25 REVISIONS MW R1 01/15/25 COLORS/FINISHES r_ ST-02 City of Arlington MP toMotchBearn BuildingDepartment PPG 1006-7 p APPROVED FINAL FOR PRODUCTION NOTES/OTHER Kevin Olander - 01 /21 /2026 File Name: Def_Driving_Arlington_S08361_PermitPack No changes authorized unless approved by 1 Survey& installation of sign(multiple components)from another location + Painting raceway I I the Building Official 1 RELEASE FOR PRODUCTION NORTHWEST SIGN & DESIGN PROJECT MANAGER: 172o1 Beaton Rd.SE Monroe,WA 98272 vciww.NWSigns.com (425)844-6415 CLIENTAPPROVAL APPROVED AS-IS ❑ APPROVED With Changes ❑ Please carefully review all contents contained herein.Your signature indicates approval of all 02023NW Sign&Design.all rights reserved.These drawings are the property solely of NW Sign&Design and are not to be used or Contractors Lic#NWWHOS'929M9 stakeholders for materials,design,colors,spelling,sizes,and fabrication and installation methods reproduced in any manner without prior written permission.Penalties of$5,000 will be charged for each page of this drawing set and/or • including responsibility for errors and omissions.The client will hold Northwest Sign&Design harmless each instance of product designs that are displayed and/or produced with unlawfully used artwork. ELECTRIC SIGNS PRODUCED AT NW SIGNS and will be responsible for compensation for changes or corrections made after approval.No work will U` CONFORM TO UL48 AND DISPLAYTHE SIGN: DATE: be started without signed approval or an appropriate waiver from the client. UNDERWRITERS LABORATORIES LABEL. EMM PRODUCTION 9'-6'1 PACK PAGE 2 of 3 ------------ ------------------------------------------- - -------- V-7 ILLUMINATI Sign Area:29.77 sq/ft PSCALF N/A O U ST 02 ILLUM. WALL SIGN - SURVEY City of Arlington & INSTALL DR IN SC 00L] g r Building Department Oty. 1 ---------------------------------------------------------- --- ------' APPROVED COLOR SUMMARY PAINT 8`-21/4" 2'-8" Kevin Olander - 01 /21 /2026 e 10'-11 3/4" No changes authorized unless approved by MP PPGTOME TCHBEAM the Building Official SATIN FINISH Front View - Existing Sign Components w.r w dw _J11► - Existing sign components(Channel letters on raceway+(2)channel clouds), mounted to beam with 3/8"lag bolts+ #12 screws(see diagram below) HIM FURNISHINGS' © - Raceway to be paintli to match beam at new location © - Connected to existing power provided by others 1 - I Attachment Details N.T.S. _ INSTALL 1 DRIVING HOOL , PER UL-48 REQUIREMENTS: . THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE '-- REQUIREMENTS OF ARTICLE 600 OFTHE �r 3/8"lags NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES.THIS Into WOOd structure INCLUDES PROPER GROUNDING AND type 6-8 per raceway ) BONDING OFTHESIGN. 2. THE LOCATION OFTHE DISCONNECT SWITCH AFTER INSTALLATION SHALL COMPLY WITH ARTICLE600.6(AN1)OF #12 SDS screws THE NATIONAL ELECTRICAL CODE. into wood structure " CLIENT INITIAL/DATE: - ICI Proposed Install Location - No Scole NORTHWEST Center on Windows / Center Vertically on Facade SIGN&DESIGN ©2023 NW Sign&Design.all rights reserved. � SO#: 8361 SITE . , PAGE 3 of DEF.DRIVING SCHOOL ADDRESS: 3704172nd St.NE,Ste I Arlington,WA 98223 PARCEL: 31052800201300 cu l'300 31052800201301 31052800201302 31052800201303 31052800201304 ZONING: �n+o sT rrt - q ] 1 r row 4 31 G52oUO2^ 1 � ��� �• � � � 3704 F2 2 37016 3704 J 3704 L 3704 N , !" 3704 K _ N W04 k r l • CLIENT INITIAL/DATE: City of Arlington I 1 I Building Department 1 APPROVED NORTHWEST Kevin Olander - 01/21/2026 SIGN&DESIGN �zoz3 NW Sign&Design,all rights reserved. No changes authorized unless approved by the Building Official SIGNAGE OVERVIEW - NOT TO SCALE m3m PROJECT PAGE I of 3 PROJECT: Def.Driv.School Install-Arlington CLIENT: I Defensive Driving School CONTACT: Jason Pierce INSTALL ADDRESS: 3704172nd St.NE,Ste I Arlington,WA 98223 PROJECT MANAGER: Gabe Stoddard SALES: Shawn Hamilton DRIVING SCHOOL ���` DESIGNER: N/A PRODUCTION DESIGNER: • Michael Wells �• DATE: 08/27/25 REVISIONS MW R1 01/15/25 COLORS/FINISHES ST-02 MP to Match Beam PPG 1006-7 FINAL FOR PRODUCTION NOTES/OTHER File Name: Def_Driving_Arlington_S08361_PermitPack 1 Survey& installation of sign(multiple components)from another location + Painting raceway I I 1 RELEASE FOR PRODUCTION NORTHWEST SIGN & DESIGN PROJECT MANAGER: 172o1 Beaton Rd.SE Monroe,WA 98272 vciww.NWSigns.com (425)844-6415 CLIENTAPPROVAL APPROVED AS-IS ❑ APPROVED With Changes ❑ Please carefully review all contents contained herein.Your signature indicates approval of all 02023NW Sign&Design.all rights reserved.These drawings are the property solely of NW Sign&Design and are not to be used or Contractors Lic#NWWHOS'929M9 stakeholders for materials,design,colors,spelling,sizes,and fabrication and installation methods reproduced in any manner without prior written permission.Penalties of$5,000 will be charged for each page of this drawing set and/or • including responsibility for errors and omissions.The client will hold Northwest Sign&Design harmless each instance of product designs that are displayed and/or produced with unlawfully used artwork. ELECTRIC SIGNS PRODUCED AT NW SIGNS and will be responsible for compensation for changes or corrections made after approval.No work will U` CONFORM TO UL48 AND DISPLAYTHE SIGN: DATE: be started without signed approval or an appropriate waiver from the client. o UNDERWRITERS LABORATORIES LABEL. EMM PRODUCTION 9'-6" PACK PAGE 2 of 3 ----------- - 1 , II— ----Sign Area:29.77 sq/ft SCALE N/A 0 ST 02 ILLUM. WALL SIGN - SURVEY 01 & INSTALL o DRS r Qty. 1 IN SC 00 COLOR SUMMARY 8`--21/4" 2�-8" PAINT 0'-11 3/4„ MP TO MATCH BEAM PPG 1006-7 SATIN FINISH Front View - Existing Sign Components - Existing sign components(Channel letters on raceway+(2)channel clouds), —0.FAU,�D�L�r$� mounted to beam with 3/8"lag bolts+ #12 screws(see diagram below) - Raceway to be painted(j►to match beam at new location - Connected to existing power provided by others Attachment Details N.T.S. —431/2" _ INSTALL DRIVING HOOL �—`� PER UL-48 REQUIREMENTS: 1. THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE RECUIRETHE 3/8"lags NATIONAL ELECTRICAL ODELE AND OR // NATIONAL ELECTRICAL CODE AND/OR LOCAL CODES. into wood structure INCLUDESHERPLICABLE PROPER GROUNDING AND HIS ' type OF THE SIGN. `7 6 S per raceway 2. THE LOCATION OFTHE DISCONNECT SWITCH AFTER INSTALLATION SHALL / #12 SIDS screws k ,�; THE NACOMPL IONALEWITH ELECTRICAL CTRICALCODELE OF r THE NATIONAL ELECTRICAL CODE. into wood structure CLIENT INITIAL/DATE: I © z ! :JIr - ICI Proposed Install Location - No Scale NORTHWEST (� (� SIGN&DESIGN Center on Windows / Center Vertically on Facade NWSIgn Deslgn.all rights reserved. � SO#: 8361 SITE . , DEF.DRIVING SCHOOL ADDRESS: — - , 3704172nd St.NE,Ste 1 — - — Arlington,WA 98223 PARCEL: ' 3105280020130 -1'300 31052800201301 ♦ 3105280020130 31052800201303 31052800201304 ZONING: i Tzw sr K - row 3704 F2 Z 3701 G -, 3704 J 3704 L 3704 N 3704 K _ iL J 1 v ,�04 I< k 4W PS 1 I i CLIENT INITIAL/DATE: I 1 I NORTHWEST SIGN&DESIGN ©2023 NW Sign&Design.all rights reserved. 4rtk( tot( WASHINGTON Permit Information - - , 1 'nformat;^ Permit# 25-0082 Parcel # 31052800201301 Building ID Location 3704 172ND ST NE Permit Type Sign Permit Use Sign Installation Zone Permit # Subdivision Applicant Name Northwest Sign & Design Address 17201 Beaton Rd SE Applicant Email permits@nwsigns.com Phone 425-844-6415 ext. 35 Cell Owner Name NORTHGATE STATION Address PO BOX 6770 KETCHUM, ID, 83340 Owner Email Phone Cell Contractor Northwest Sign & Design Address , Contractor Email permits@nwsigns.com Phone 425-844-6415 ext. 35 Cell Property Information Type/Improveme Minor Improvement Accessory/Struct nt ure Current Use B Business Proposed Use Current Zoning 13 Proposed Zoning Project Cost 835.00 Project Value 835.00 Current Use And New wall sign installation Proposed Changes Lot Width Lot Depth Map Number Total Area of Building & Accessory Total Area of All Man-made Improvements Structures (Sq Ft) (Sq Ft) General Notes Restrictions/ Variances @ Community Development Online Portal Page 1 of 6 March 20, 2026 04:45PM WASHINGTON Structure Information Structure Type # of Stories 1 Usable Floor Area (Sq Ft) Structure Height null # of Units 0 Load per Floor (Lbs) Sign Dimensions # of Bedrooms null # of Bathrooms null Occupancy With Chairs Tables & Chairs Empty Room Foundation Foundation Type Footing Depth null Material Foundation Information Setbacks Front& 0 0 Setbacks Right & 0 0 Rear Left Sides Setbacks Information Water Utility Public Sewage Utility Public Gas Utility Public Electric Utility Public Driveway Width null # of Off Street null # of Off Street null Parking Loading Miscellaneous Information ©Community Development Online Portal Page 2 of 6 March 20, 2026 04:45PM WASHINGTON Contractors License # Business Name Type Contact 602 156 837 Northwest Sign & Design Out of City Adriel Blake ©Community Development Online Portal Page 3 of 6 March 20,2026 04:45PM WASHINGTON Inspections Inspection # Inspection Type Status Date Inspector 26-0076 Sign - Final Pass February 6, 2026 Kevin Olander ©Community Development Online Portal Page 4 of 6 March 20,2026 04:45PM 4rtk( tot( WASHINGTON Contacts Contact Name Type Project Address Phone NORTHGATE STATION Owner PO BOX 6770 KETCHUM, ID, 83340 Northwest Sign & Design Applicant 17201 Beaton Rd SE 425-844-6415 ext. 35 Defensive Driving School Occupant 3704 172nd St NE, STE 1 425-315-5436 Northwest Sign & Design Contractor 17201 Beaton Rd SE, 425-844-6415 ext. 35 Monroe, WA 98272 ©Community Development Online Portal Page 5 of 6 March 20, 2026 04:45PM 4rtk( tot( WASHINGTON Fees Fee Type Date Debit Credit Balance Permit Fees December 1, 2025 $126.59 $126.59 $126.59 $0.00 T O T A L $126.59 $126.59 $0.00 ©Community Development Online Portal Page 6 of 6 March 20, 2026 04:45PM