Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
526 French Ave Unit B_BLD1562_2026
RESIDENTIAL MECHANICAL PERMIT APPLICATION t�N Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:526 N French Ave Project Description-AC add Owner: Karla Swanson Address. 526 N French Ave City. Arlington State WA Zip Code: 98223 Phone. 4253207762 Email:N/A Applicant: Black Lion HVAC Address: 11001 118TH PL NE City. Kirkland State.WA Zip Code: 98033 Phone. 425-814-3944 Email. BRENDA@BLACKLIONHVAC.COM CONTRACTOR INFORMATION Contractor Name:BLACK LION HVAC Address: 11001 118TH PL NE City: Kirkland State WA Zip Code: 98033 License Number: BLACKLH873QQ Expiration: 11/17 Phone: 425-814-3944 Email:INFO@BLACKLION HVAC.COM STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 Y. RESIDENTIAL MECHANICAL PERMIT APPLICATION SING Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES ❑ Furnace (80+) Model # AFUE ❑ Heat Pump Model # AFUE HSPE AC Unit Model # Bryant 124 SEER 14 ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: ❑ Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Fe� ...Arzl Applicant Signature: Date: 07/20/2017 Applicant Printed Name: Brenda Lopez I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 PREFERRED 7M SERIESI' CONDITIONER WITII PURON@ REFRIGERANT NONUNAL TONSo Product Data INDUSTRY LEADING -munnunnumm�mmunnnnnnmrnn FEATURES/BENEFITS I I I I I I I I I I!!I I I I I I I I I I I I I I I I I I I I I I I I I!!I I I I I I II I I I I If 111111111111111111111111111111lllllllllllllllmllll Energy Efficient IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIm �I gy y IIIIIIIIIIIIIIIIIIIII[I!IlIIIIIIIIIIIIIIIIIIII • 14 SEER/11.7- 12.2 EER llllll111111111111lIlllliillllilillllll[IIlIII di (Based on tested combinations) llllllllllllllllllllllillllflf!Illyllllll]III Sound 1111111111111lIlilllllillllllllllll�llml� IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII��II�I 1 Levels as low as 66 dBA IIIIIIIIII�lIIn; ;Innm 11;illlll11, If lln Design Features N�IhlIIIIII,LIII�II�lI�I�iiiiiiiiiiiiiilll a • Small footprint • DuraGuard- cabinet Preferred TM —All steel cabinet construction Nron. 9051110FE50 —Mesh coil guard Reliability, Quality and Toughness Bryant air conditioners with Puron o refrigerant provide a • Scroll compressor collection of features unmatched by any other family of • Factory-supplied filter drier equipment. The 124ANS has been designed utilizing Bryant's Puron refrigerant.This environmentally sound refrigerant allows • High pressure switch you to make a responsible decision in the protection of the earth's • Low pressure switch ozone layer. • Accumulator NOTE: Ratings contained in this document are subject to • Line lengths up to 250'(76.2 m) change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up-to-date ratings • Low ambient operation information. (down to -20°F/-28.9°C with low ambient accessories) MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 14 N N N A A/N N N N N A/N A/N N A 1 2 4 A N S 0 3 6 0 0 0 A Product Tier SEER Variations Voltage Variations Cooling Open Open Open Series Family 2=Preferred 4=14 SEER S=Side Discharge N=208/230-1 S=Stan- Capacity O=Not O=Not O=Not A= 1 =AC P=208/230-3 dard Defined Defined Defined Original E=460-3 Series CERTIFIED- ruron C UL US Use of the AHRI Certified TM Mark indicates a manufacturer's participation in the program For verification of certification for individual products,go to www.ahridirectory.org. PHYSICAL DATA UNIT SIZE—SERIES(VOLTAGE) 18—A 24—A 30—A 36—A 48—A 60—A (N) (N) (N) (N,P,E) (N,P,E) (N,P,E) COMPRESSOR TYPE Scroll REFRIGERANT Puron®(R-410A) Charge lb(kg) 6.40(2.90) 6.50(2.95) 8.60(3.90) 8.90(4.04) 9.00(4.08) 10.60(4.81) COND FAN Propeller Type,Direct Drive Air Discharge Horizontal Air Qty(CFM) 1285 1285 1900 2615 2615 2785 Motor HP 1/12 1/12 1/10 1/4 1/4 1/4 Motor RPM 800 800 800 800 800 800 COND COIL Face Area(Sq ft) 7.3 7.3 12.1 12.1 12.1 14.1 Fins per In. 20 20 20 20 20 20 Rows 2 2 2 2 2 2 Circuits 3 3 3 3 3 4 VALVE CONNECT.(In.ID) Vapor 5/8 3/4 3/4 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES*(In.OD) Rated Vapor* 5/8 3/4 3/4 7/8 7/8 1 1/8 Max Liquid Linet 3/8 *Units are rated with 25 ft(7.6 m)of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. Note: See unit Installation Instruction for proper installation. t See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables. 2 REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line Sizing and Maximum Total Equivalent Lengthst for Cooling Only Systems with Puron®Refrigerant: The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units. See Table below for liquid line sizing and maximum lengths: Maximum Total Equivalent Length Outdoor Unit BELOW Indoor Unit Liquid AC with Puron Refrigerant Maximum Total Equivalent Lengtht: Outdoor unit BELOW Indoor Size Liquid Line Line Vertical Separation ft(m) Connection Diam. 0-5 6-10 11-20 21-30 31-40 41-50 51-60 61-70 71-80 W/TXV (0-1.5) (1.8-3.0) (3.4-6.1) (6.4-9.1) (9.4-12.2) (12.5-15.2) (15.5-18.3) (18.6-21.3) (21.6-24.4) 018 1/4 150 150 125 100 100 75 —— —— —— AC with 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 225* 150 Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 024 1/4 75 75 75 50 50 —— —— —— —— AC with 3/8 5/16 250* 250* 250* 250* 250* 225* 175 125 100 Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 030 1/4 30 -- -- -- -- AC with 3/8 5/16 175 225* 200 175 125 100 75 -- -- Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 036 5/16 175 150 150 100 100 100 75 —— —— AC with 3/8 Puron 3//8 250* 250* 250* 250* 250* 250* 250* 250* 250* 048 AC with 3/8 3/8 250* 250* 250* 250* 250* 250* 230 160 —— Puron 060 AC with 3/8 3/8 250* 250* 250* 225* 190 150 110 -- -- Puron * Maximum actual length not to exceed 200 ft(61 m) t Total equivalent length accounts for losses due to elbows or fitting.See the Long Line Guideline for details. -- =outside acceptable range Maximum Total Equivalent Length Outdoor Unit ABOVE Indoor Unit Liquid AC with Puron Refrigerant Maximum Total Equivalent Lengtht: Outdoor unit ABOVE Indoor Size Liquid Line Line Vertical Separation ft(m) Connection Diam. 25 26-50 51-75 76-100 101-125 126-150 151-175 176-200 W/TXV (7.6) (7.9-15.2) (15.5-22.9) (23.2-30.5) (30.8-38.1) (38.4-45.7) (46.0-53.3) (53.6-61.0) 018 1/4 175 250* 250* 250* 250* 250* 250* 250* AC with 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 024 1/4 100 125 175 200 225* 250* 250* 250* AC with 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 030 1/4 30 -- -- -- -- AC with 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 036 5/16 225* 250* 250* 250* 250* 250* 250* 250* AC with 3/8 Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 048 AC with 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250* Puron 060 AC with 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250* Puron *Maximum actual length not to exceed 200 ft(61 m) t Total equivalent length accounts for losses due to elbows or fitting.See the Long Line Guideline for details. -- =outside acceptable range 3 REFRIGERANT CHARGE ADJUSTMENTS Liquid Line Size Puron Charge oz/ft(g/m) 3/8 0.60(17.74) (Factory charge for lineset=9 oz/266.16 g) 5/16 0.40(11.83) 1/4 0.27(7.98) Units are factory charged for 15 ft(4.6 m)of 3/8"liquid line. The factory charge for 3/8"lineset 9 oz(266.16 g). When using other length or diameter liquid lines,charge adjustments are required per the chart above. Chareine Formula: [(Lineset oz/ft x total length)-(factory charge for lineset)]=charge adjustment Example 1: System has 15 ft of line set using existing 1/4"liquid line. What charge adjustment is required? Formula: (.27 oz/ft x 15ft)-(9 oz)=(-4.95)oz. Net result is to remove 4.95 oz of refrigerant from the system Example 2: System has 45 ft of existing 5/16"liquid line.What is the charge adjustment? Formula: (.40 oz/ft.x 45ft)-(9 oz.)=9 oz. Net result is to add 9 oz of refrigerant to the system LONG LINE APPLICATIONS An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter,actual length of the tubing,and vertical separation between the indoor and outdoor units. For Air Conditioner systems,the chart below shows when an application is considered Long Line. AC WITH PURONO REFRIGERANT LONG LINE DESCRIPTION ft(m) Beyond these lengths,long line accessories are required Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor 1/4 No accessories needed within allowed No accessories needed within allowed 175(53.3) lengths lengths 5/16 120(36.6) 50(15.2)vertical or 120(36.6)total 120(36.6) 3/8 80(24.4) 35(10.7)vertical or 80 24.4)total 80(24.4) Note: See Long Line Guideline for details VAPOR LINE SIZING AND COOLING CAPACITY LOSS LONG LINE APPLICATION: An application is considered vertical separation is 200 ft. (60.96 m) when outdoor unit is "Long line"when the total equivalent tubing length exceeds 80 above indoor unit, and up to 80 ft. (24.38 m)when the outdoor ft. (24.38 m)or when there is more than 20 ft. (6.09 m)vertical unit is below the indoor unit.Refer to Accessory Usage Guideline separation between indoor and outdoor units. These applications below for required accessories. See Longline Application require additional accessories and system modifications for Guideline for required piping and system modifications. Also, reliable system operation. The maximum allowable total refer to the table below for the vapor tube diameters based on the equivalent length is up to 250 ft. (76.2 m). The maximum total length to minimize the cooling capacity loss. Vapor Line Sizing and Cooling Capacity Losses—Puron®Refrigerant 1-Stage Air Conditioner Applications Unit Maximum Vapor Line Cooling Capacity Loss(%) Nominal Liquid Line Diameters Total Equivalent Line Length ft.(m) Size(Btuh) Diameters (in.CD) 26-50 51-80 81-100 101-125 126-150 151-175 176-200 201-225 226-250 (in.CD) (7.9-15.2) (15.5-24.4) (24.7-30.5) (30.8-38.1) (38.4-45.7) (46.0-53.3) (53.6-61.0) (61.3-68.6) (68.9-76.2) 018 1/2 1 2 3 5 6 7 8 9 11 1 Stage AC with 3/8 5/8 0 1 1 1 2 2 2 3 3 Puron 3/4 0 0 0 0 1 1 1 1 1 024 5/8 0 1 2 2 3 3 4 5 5 1 Stage AC with 3/8 3/4 0 0 1 1 1 1 1 2 2 Puron 7/8 0 0 0 0 0 1 1 1 1 030 5/8 1 2 3 3 4 5 6 7 8 1 Stage AC with 3/8 3/4 0 0 1 1 1 2 2 2 3 Puron 7/8 0 0 0 0 1 1 1 1 1 036 5/8 1 2 4 5 6 8 9 10 12 1 Stage AC with 3/8 3/4 0 1 1 2 2 3 3 4 4 Puron 7/8 0 0 0 1 1 1 1 2 2 048 3/4 0 1 2 3 4 5 5 6 7 1 Stage AC with 3/8 7/8 0 0 1 1 2 2 2 3 3 Puron 11/8 0 0 0 0 0 0 0 1 1 060 3/4 1 2 4 5 6 7 9 10 11 1 Stage AC with 3/8 7/8 0 1 2 2 3 4 4 5 5 Puron 11/8 0 0 0 1 1 1 1 1 1 Applications in this area may beog line and may hie heigWstrictions. See the Residential Piping and Long Line Guideline. 4 ACCESSORIES Unit Size(Voltage/Series) KIT NUMBER KIT NAME 018 024 030 036 036 036 048 048 048 060 060 060 (30) (30) (30) (30) (50) (60) (30) (50) (60) (30) (50) (60) KAACH1401AAA Crankcase Heater X X X X X KAACH1201AAA Crankcase Heater X X X X KAACH1501AAA Crankcase Heater X KAACH1901AAA Crankcase Heater X X KAAFT0101AAA Evaporator Freeze Stat X X X X X X X X X X X X KAATD0101TDR Time Delay Relay X X X X X X X X X X X X KAAWS0101AAA Winter Start Kit X X X X X X X X X X X X KSALA0801AAA MotorMaster®230v X X X X X X X X X KSALA0901AAA MotorMaster®460v X X X 53DS-900---087 Wind Baffle X X 53DS-900---071 Wind Baffle X X X X X X X 53DS-900---088 Wind Baffle X X X 53DS-900---075 Stacking Kit X X 53DS-900---076 Stacking Kit X X X X X X X X X X 53DS-900---077 Wall Mounting Kit X X 53DS-900———078 Wall Mounting Kit X X X X X X X X X X KAALP0401PUR Pressure Switch Kit X X X X X X X X X X X X KSASH2301COP Sound Blanket Kit X X X X X X KSASH2401COP Sound Blanket Kit X X X X X X KAALS0201LLS Solenoid Valve Kit X X X X X X X X X X X X KSAHS1501AAA Capacitor Relay Start X X X X X X Assist X=Accessory ACCESSORY THERMOSTATS PART NUMBER DESCRIPTION T6-WEM01 HousewiseM Wi-Fi®thermostat T6-PRH01-A Programmable Relative Humidity Thermostat T6-PAC01 Programmable Thermostat T6-NRH01 Non-Programmable Relative Humidity Thermostat T6-NAC01 Non-Programmable Thermostat T2-WHS01 Wi-Fi®Thermostat T2-PAC01 Programmable Thermostat T2-NAC01 Non-Programmable Thermostat T2SNAC01 Non-Programmable Standard Screen Thermostat THERMOSTAT ACCESSORIES PART NUMBER DESCRIPTION THERMOSTATS USED WITH T6-EXP EXP®Card T6-Pxx,T6-Nxx TSTATXXSEN01-B Outdoor Air Temperature Sensor T6-Pxx,T6-Nxx TSTATXXCNV10 Thermostat Conversion Kit(4 to 5 wire)-10 pack All Bryant®branded thermostats TX-MBP01 Medium Decorative Backplate T2-Nxx TX-LBP01 Large Decorative Backplate T6-Pxx,T6-Nxx,T2-Pxx 5 ACCESSORY USAGE GUIDELINE REQUIRED FOR LOW-AMBIENT REQUIRED FOR REQUIRED FOR Accessory COOLING APPLICATIONS LONG LINE APPLICATIONS* SEA COAST APPLICATIONS (Below 55°F/12.8°C) (Over 80 ft./24.38 m) (Within 2 miles/3.22 km) Ball Bearing Fan Motor Standard Standard Standard Compressor Start Assist Capacitor and Yes Yes No Relay Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Liquid Line Solenoid Valve No See Long-Line Application No Guideline Low Ambient Pressure Switch or Yes No No MotorMaster®Controller *For tubing line sets between 80 and 200 ft.(24.38 and 60.96 m) and/or 20 ft.(6.09 m)vertical differential,refer to Residential Split-System Longline Application Guideline. Accessory Description and Usage (Listed Alphabetically) 1.Ball-Bearing Fan Motor 4.Evaporator Freeze Thermostat A fan motor with ball bearings which permits speed reduction An SPST temperature-actuated switch that stops unit operation while maintaining bearing lubrication. when evaporator reaches freeze-up conditions. Usage Guideline: Usage Guideline: Required on all units when using MotorMaster@ Required when low ambient kit has been added. 2.Compressor Start Assist-Capacitor and Relay 5.Low-Ambient Pressure Switch Kit Start capacitor and relay gives a "hard" boost to compressor A long life pressure switch which is mounted to outdoor unit motor at each start up. service valve. It is designed to cycle the outdoor fan motor in Usage Guideline: order to maintain head pressure within normal operating limits. Required for reciprocating compressors in the The control will maintain working head pressure at low-ambient following applications: temperatures down to WIT(-18°C)when properly installed. Long line Usage Guideline: Low ambient cooling A Low-Ambient Pressure Switch or MotorMaster@ Low-Ambient Controller must be used when cooling Hard shut off expansion valve on indoor coil operation is used at outdoor temperatures below 55°F Liquid line solenoid on indoor coil (12.8°C). Required for single-phase scroll compressors in the Suggested for all commercial applications. following applications: 6.MotorMaster Low-Ambient Controller Long line A fan-speed control device activated by a temperature sensor, Low ambient cooling designed to control condenser fan motor speed in response to the Suggested for all compressors in areas with a history of saturated condensing temperatures down to -20°F(-28.9°C),it low voltage problems. maintains condensing temperature at 100°F +/- 10°F (37.8°C 3.Crankcase Heater +/-6°C) An electric resistance heater which mounts to the base of the Usage Guideline: compressor to keep the lubricant warm during off cycles. A MotorMaster Low-Ambient Controller or Improves compressor lubrication on restart and minimizes the Low-Ambient Pressure Switch must be used when chance of liquid slugging. cooling operation is used at outdoor temperatures Usage Guideline: below 55°F(12.8°C). Required in low ambient cooling applications. Suggested for all commercial applications. Required in long line applications. Suggested in all commercial applications. 6 ELECTRICAL DATA UNIT SIZE OPER VOLTS* COMPR FAN MAX FUSE**or SER(VOLTAGE) MAX MIN LRA FLA FLA CKTBRKAMPS 018-A(N) 56.3 9.0 0.50 11.8 20 024-A(N) 62.9 10.9 0.50 14.1 25 030-A(N) 73.0 14.1 0.70 18.3 30 036-A(N) 208/230/1 253 197 77.0 14.1 1.20 18.8 30 048-A(N) 124.0 18.5 1.20 24.3 40 060-A(N) 152.5 23.7 1.45 31.1 50 036-A(P) 71.0 9.0 1.20 12.5 20 048-A(P) 208/230/3 253 197 83.1 13.7 1.20 18.3 30 060-A(P) 110.0 15.9 1.45 21.4 35 036-A(E) 38.0 5.6 0.60 7.6 15 048-A(E) 460/3 506 414 41.0 6.2 0.60 8.4 15 060-A(E) 52.0 7.1 0.80 9.7 15 LEGEND: FLA -Full Load Amps HACK -Heating,Air Conditioning,Refrigeration LRA -Locked Rotor Amps NEC -National Electrical Code RLA -Rated Load Amps(compressor) Permissible limits of the voltage range at which the unit will operate satisfactorily * Time-Delay fuse. Complies with 2007 requirements of ASHRAE Standards 90.1 A-WEIGHTED SOUND POWER (dBA) Standard Typical Octave Band Spectrum(dBA,without tone adjustment) Unit Size Rating (dBA) 125 250 500 1000 2000 4000 8000 18 69 50.5 57.0 59.5 64.5 60.5 53.5 43.0 24 66 50.5 58.5 60.5 59.5 56.5 51.0 41.5 30 68 55.5 59.5 61.5 63.5 60.0 58.0 49.5 36 71 59.5 59.5 62.0 65.5 63.5 62.0 55.0 48 70 57.5 59.5 64.0 66.0 63.0 60.5 54.5 60 73 60.0 61.5 64.5 67.0 66.0 65.5 58.0 NOTE: Tested in accordance with AHRI Standard 270-08(not listed in AHRI). A-WEIGHTED SOUND POWER (dBA) WITH ACCESSORY SOUND SHIELD Standard Typical Octave Band Spectrum(dBA,without tone adjustment) Unit Size Rating (dBA) 125 250 500 1000 2000 4000 8000 18 68 52.5 58.0 58.5 64.5 59.5 52.5 42.5 24 65 54.5 57.5 59.5 59.0 56.0 50.5 40.5 30 68 55.0 60.0 61.5 62.5 60.0 58.0 49.5 36 71 59.5 59.5 62.5 65.0 63.0 61.5 55.0 48 70 57.5 59.5 63.0 65.0 62.5 60.0 54.0 60 73 61.0 62.0 64.0 67.0 65.5 65.5 57.5 NOTES: Tested in accordance with AHRI Standard 270-08(not listed in AHRI). Accessory sound shield will not accommodate unit sizes 18 and 24. CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) UNIT SIZE-SERIES REQUIRED SUBCOOLING°F(°C) 18 12(6.7) 24 12(6.7) 30 12(6.7) 36 8(4.4) 48 12(6.7) 60 10(5.6) 7 d° - E m - ¢ E E _ X �� Ems'" _2Eu� _ aid E`D co$ - a1Oi E>>u S m M C7 Sm X x oz am"ovmi� =Z x o0 o EE .o 2a 2 a'S Es EE RE,9 E cEt Z - -��EE W U IEtEm O v o000 `oo � 'o `E�-b om N - w o d`m 'o c E aai ¢< CL `-j L°3V�� - ccT000E 2 W 'I EaF-I _ C7 y rA EEaN. oo_ v mE EE``Ec = = d EE�m.c m'^° w W f a E �3 ¢g o`.1 E.0-c a gam= -E <E'o N c`-'n 1 c E y rn Li d A E 3 m=E a -m E u"icu--c m3r mo ca � s o c m ER J m O O II 2 w w N a m CA a xo w a N cyi...... 09-E-094 z ¢N _ W ..... 09-E-OCZ/80Z - a 1 Ln JQ000000 09IOEZ 3 ��, X U1 LU �Zz z 09-1 OEZ 80Z " g _ O w o �o w 0: o 0 0 0 0 o LL N N o z w o0000 A s ENS 3° X'� E �`� E`aE =2E U. X x -" EEn E.a� d Ec !a N�a z . Ln x EE oEo�o t Ev @d O- NEyoE�`O Zn 0 o Ego °E —El z mo E'--" _ W - m o`m'E V E a _ - sc2ao�Eo6N cm 00 m a Eco dE ;o3- z Y 3�a EEaE cL.o E20._a E m m(=j a 'mE E Efa -_°a d W n�E EEoim_-=_ m 03 aE g2,w a E of v E.3 m- 00 12 Z o00000 �o�AN-�$� AzEQE�o � � 4 Ay°' wEo�v r2 rco 33 o`o g 2 So`u J o�� Y 7 m o 2 fA o 00 _ 7 LL 4 � W IL U o0000o z � m o 0 0 0 o J Q o o xo W U 09-E-09b Q l~A LL s L)w o 0 0 0 0 0 09-£-0£Z/80Z a„, ICI V1 L'<...... 09-1-0£Z �CDZ x x WQ zz ED L) 09-1-0£Z-80Z E o z W OU) LL Z w A 9 TESTED AHRI COMBINATION RATINGS* NOTE: Ratings contained in this document are subject to change at any time. For AHRI ratings certificates,please refer to the AHRI directory www.ahridirectory.org Additional ratings and system combinations can be accessed via the Bryant database at:www.MyBryantRatings.com For performance data at specific application&/or design conditions with various indoor unit combinations,the equipment performance calculator can be accessed at: http://rpmobbmwrightsoft.com/ Outdoor Model Number— Indoor Coil Model Number Furnace Model Number Capacity EER SEER Series(voltage) 124ANS018—A(N) CNPV*3014AL*+TDR 18,000 12.2 14 124ANS024—A(N) CNPV*3117AL*+TDR 24,000 12.2 14 124ANS030—A(N) CNPV*3117AL*+TDR 29,600 12.2 14 124ANS036—A(N,P,E) CNPV*3717AL*+TDR 35,400 12.2 14 124ANSO48—A(N,P,E) CNPV*6024AL*+TDR 45,000 11.7 14 124ANS060—A(N,P,E) CNPV*6124AL*+TDR 57,000 11.7 14 EER —Energy Efficiency Ratio SEER—Seasonal Energy Efficiency Ratio TXV —Thermostatic Expansion Valve NOTES: 1.Ratings are net values reflecting the effects of circulating fan motor heat.Supplemental electric heat is not included. 2.Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners.Ratings for other combinations are determined under DOE computer simulation procedures. 3.Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 4.Do not apply with capillary tube coils as performance and reliability are significantly affected. 10 �p y x O O O O O M M M M M c0 c0 N t0 t0 �p y x I� t` O O O 0 0 0 0 N 7 7 7 7 0 �'3 000000000000000 0 �'3 tOtOtOtOtOnnnnnnnnn � n n 7 C O M OD t0 t0 N N t0 O O V N C 1� m M M M V 6 V m m c N V V M N N D) - O M M 0j N — 7 7 0 M 4 N 7 7 N y — 7 7 O M N — —6 6 M M M — O m m c m WW N r O m M N O m L0 M w 7 w m W M m M 7 7 M O 0p N m W N 7 t0 t0 (M Il O 7 m M l0 N W W N M m (M M 7 L0 N m m l0 Il (M 7 (M U h ro a m m m 16 It m a a ID a m a a U h of ad ad of ad a2 a2 of a2 of of N N N {p y K m m m m m N N N N N m m 7 7 7 W y x O M O OD O M M N N N I- O O O O O T 3 r r r r r . . . . . . . . . . O T 3 V M M M M 7 7 7 7 7 7 7 7 7 7 N Y f N Y N N N N N N N N N N N N N N N aLn Ly M N m M t0 O O N N O N M m L O O aD m 7 0 0 1� m 1� N N M 7 C 7 0 N 7 7 m I C N L0 m N 7 m I� O N t0 CD O Il 1` N 0j 7 7 N N N N O M N N N `y N N 7 m m N t0 t0 N N M n n N N p, c0 a0 a0 a0 c0 M N N N a0 N O m p, y W fM t0 a s 7 t0 m 1� O O t` m N 7 y W m LV 7 N 7 t0 N (M (M CD Il 1` {p y� 7 M M M M t0 t0 t0 t0 t0 W y x N 7 7 7 7 m M M M M M N N N �. — — — — — — — t0 t0 t0 t0 t0 t0 t0 t0 7� N N N N N A N Y f N Y N N N N N N N N N N N N N N N U U LL Iq LL ° a L y M N m c0 aD c0 7 I� O a0 c0 ° a L O m 7 a0 N M a0 N c0 N 7 M a0 N C M N t0 N N M N M M m m M M M (n C OD 0 7 N N N N N M M N 7 t0 m m W� C m to N 7 m 0 M N 6 6 0 M M w w W� C m to N O N N N M n O N N 4 M ^ N N W eL O M w m O O w 7 O N w 0W p, a0 O M a0 N O N c0 N 7 a0 a0 N 1 W W N I� 7 N N r O r m M O N m M M a y W 7 M Il N N OD t0 O M M O OD N m m Lu U O OD t0 N N N OD I� N N N m 1� N t0 t0 U O 7 N 0 0 0 7 N N N W f W f N N N N N N N N N N N N N N N f f Q Q Z W y x N N N N N M M o o o o o m m m O O O Wf `J.3 7 7 7 7 7 7 7 7 7 7 m m m m N W H >.3 m m m m m m m m m m 0 0 0 0 0 F N Y F N Y — N N N N N W W Ix Lu N Ln v O c0 c0 I� O O m O a0 N N v 0 0 7 M M 7 0 w N m w w 7 aD W N C N N m c0 N M It- I� W N C M t0 m CD N O CD 0 7 M Il m 0 G m m W O N N 7 L0 0 M N t0 t0 7 M I� r o m m W M t0 L0 N a O O N N Z N Z N U U u n WW • O r O O M m N N t0 0p N W • N M t0 N M M O M N m m I� O aD W l0 t0 fM m m 0 t0 c0 l0 N CD W W m 0 m 0m M O M 7 M m N 0O U O 0j 1� t0 t0 N m aD t0 t0 t0 O aD t0 I� t` U O N M t0 7 N N N t0 7 N M M {p y 7 7 M M M t0 t0 t0 t0 t0 W y x N 7 7 M M m M 1� r r M N N r M`♦. r r r r r r r r- r — M M M �yY ANY a' In M M Lq a n M m m a m N m ++ n m N a M m a o c0 ul c0 M c0 M N q m 7 M � OD N N N w1� O m aD V1 pNp N O N N — — - M M — — — 7 7 — t` � 2 N W2.1 y W N N W O M O WN p, N t0 M y (M LV I� 7 M N V M O (0 (V U U O O aD O O O m m U O 7 M N N m M M M O m M 7 7 — 77 W y x M M M M M 7 7 7 7 7 W y i*i OD I� r r r N t0 N N N N N N N N N N N N N N t0 t0 t0 t0 t0 t0 t0 t0 t0 t0 �U HVIY ANY M N r O N M N N N M O M M M I� m m m N N 0p N M N C m M 10 w Iwo0 m N w m m o 7 t0 t0 v C N m O I- N m F- 0 7 N IZ m n m N C M N 6 1' 7 M t0 Il N N 7 O O n m to 7 I� O N N 7 CD O N N 6 m m N N O W 1� V V V N N V M O W (0 O O m M M m M (0 M V N m M w M M N N O W W a v m t0 m M M m N t0 t0 t0 W W O O N m N N t0 M N 7 O O r r UU O O r r r O OD OD N O m m m U O Op p 7 M M m 0 a a a m 0 N N N W 3 N 7 N m N 7 N m N 7 N m a �FQ Uv�vvvmvvvmvv �F W LL° NvNI� 7rO NMO INO mrN NvNI� 7rO NMO .NO mrN NvNI� .rO NMO NO m O O rN aC O C-' O O W o Q LL N c tn0 Q LL n c o C A � U � U � U) 11 q E* jp y* M N N N N y r M M M O W W x M N N N N 7 N N O M I- M M M M M M M 7 M M M M 7 7 7 M M M M M m m m m m O m m m m FyFy ai m m m m m m m m m m m m m m FyY m m m m m m m m m m a m m mm n n a m n M e N NL C M O M O M O M N M M N M7 MN O N M M N M 0 - N NN OMN N NI- N N m yN M N NN NN 7 M Mc6 MN MNNONyMN MN NN WC N O N N M M y N N N N N N N N N N N N N CL M N N 7 M O M M N 7 CL N M M O N N M M M M O M M 7 M I. M N M M W W N m 0 Il r M N M N N 0 7 N N N U F t0 (M N N N N 7 N M M N 7 N M M U O E O M N N N N M N M M N y M y y rW«• ««• O O m m m 0 0 0 0 0 0 0 0 0 0 `J. N 7 7 7 7 N N N N N N N N N N .0 L C 7 N 7 M Il M N Il t` t` � m m 7 7 � C m � � N N � O M N N N I� 7 M M MN M m y � N U p_ 7 I� O t` N M M 0 7 0 M M N a In M M M M I- I- N N 7 M N W W N N M M Il N O N Il t` m 7 N 7 7 W W M 7 M N N I` N N IN y 0 y (M (M U F OD N M M M M N 7 7 7 M N 7 N N U O (M O M M M M O M y y M M O O E. E. «I* N N N N N N N F y[ F y[ N N N N N N N N N N N N N N N F inY M M M M M M M M M M M M M M M U LL a M M L C .- M m O m N 7 I- N N m m y C y N m IN 7 6 6 N IN N M Il N N R O m y N N - N - N N - N N N N ¢ O m y N N M M N N N M M N N N M M k Q W C W L M a N M m N N � N M M y N a a M M r- M In O N N O O m N 1 W W 7 7 O N m M a a O N N m M a W W • M Il 7 (M (M (M M N 7 N N N M M W F M N N N N N M N N N N N M N N N N F F M M M M M M M M M M M M M M M Q Q Q «O b 3 «O 3 7 7 M M M 7 7 7 7 7 7 7 7 7 7 C `♦.3 M M M M M y y M M M y y y y y F F N 1[ F y Y N N N N N N N N N N N N N N N � F y Y N N N N N N N N N N N N N N N W Z ¢ W Ln W M a s M y O N M y M N 7 Z t N M N M O N O � O O N N y 0 7 M 7 N N M M W N C r m M M m M M N N O N M N Z pl N N M M M N N O O I- t` t` N O m y � N N � N N N N N N N N Z y N N N M M N N N M M N N N M M U O Cl) N M M N O M M M 7 M V CL O M O N V O N O LN O M O N M IN N IN N 7 7 (M y O M fM M W W M M 7 0 M M 7 M N N I'- M N U f m W W W N M I- N O I- M M U O w 7 N N M N N M M M N M 7 7 M N N N N M N N N N M M N N N M M M M M M M M M M M M M M M r • E E� N N M N N N 7 M M M W W K O M N N N N 7 N N N N O M M M n «« d•3 N N N N N I- I- N N N F y[ F Y M N M N N N N N N N N N N N N N N N F y Y N N N N N N N N N N N N N N N vM M N N N O m M Il r O N M M N y y N N N N N M M N N N M M N M N M M W CD m y N N N N N N N N N N N co y T ¢ N N V N 1� N 1� M N N M V M m N CL 1� V M 1� M 1� M 1� M N M 1� M m « N N M M M N M N N I� N M N N W W N M M r 7 M LN M N M M UU 10 q y y M N N O O y M N M M M M N N N W W x N 7 N N N O M M M M N 7 7 7 « M m m m M m m m m m O m m m m >. M M M M M 7 7 M M M 7 7 7 7 7 UF y[ F y[ N F y Y N N N N N N N N N N N N N N N z N N N M O N O N M M ° O 1� ,N,,, L C M N M fM fM I� O N N N M 7 1� t` C N 7 7 N 1� 7 M N O N N M 7 M N N N O m 7 M N N m M M N 6 0 y y N I- N N 7 M m M N N 7 m I` I` O � O U p, O M N M M O IN 0 7 IN 7 M N N Wp, M M N M M M 7 I4 t` M 7 mM N N M N M m N m � m 7 r M Il t` W W N I, M N 7 N N M 7 M y I� � m � U U O N M M M N N O M M N M 0 0 0 U O N M N N 7 M M N N N M M t` t` M M N N N M M M N N M M M M M f 7 M M M 777 7 MM M M V M M M M W N 7 N N N 7 N N N 7 N m ¢ N 7 N N N 7 N N N 7 N m Q W LL N I- M N r N r M N r N r M N r O W LL N r M N r N r M N r N r M N r O_ [� Q O O W w N o a N o N V m U C AW 12 W W x O 0 M 7 7 M 7 M M 0N M N (0 W x N M M 0 M M M 0 7 V O `�•3 M N N N N M M M M M 7 7 M 7 7 `J.3 r (q l0 tO t0 a. r r r r O) cq cq cq M F N Y N N N N N N N N N N N N N N ui H N Y O O O O O O O O O O O O O O O A A v t r m O O O M 1� M O) O) M O 0 0 v L 0 0 0 0 0 0 7 1� r N O O m m 0 C N M (O OD t` O O ow t` ow m (O (O C N 7 M O M 0. r M N N 7 w (O N N N W M O) cD 7 7 7 N O (0 (0 (0 7 N 6 6 N W M O (V (n N N N M M N M M M M N M M M M N mm N M M 7 7 N M M 7 7 M 7 M 7 V cL W 7 0 w M w O M m 0 7 0 M M w 0 7 w m N N t` M m N O W r M (0 0 00 cq 7 cq t` M 1� (P (P W r N O O) O q (0 7 7 N N Il t` t` N N C C O W W K w N 0) 0 0 7 I- 0) 0) N O) (O OD t` W W x 7 0D M 7 7 N OD M w m m M ca3 n m . n . a. nn . . . ao 0 >3 ornrnrnrn � o00oN � � � � m h N Y v a a a a a a a a a a a a a a h N Y ro N N N ui ro ro ro ro ro ro ro ro ro � t m y W 1� O r N r M m M N I� N O r O N m w N M m M M I� M r m C V cq N cq M q 7 M (0 cq M M C r q 7 0 7 (O q (O (0 q N M 00 Il p N M M M o) N W M 1� O t` t` O M M M N M m m o (n N M N M M N M M M M N M M (n N M M V V M V M 7 V M V V V V O lj lj O p, O O O N I� N N N N n n I- m w N p, N N O N O 7 O N M n a 00 (O N j W W M (O q N I� O M 7 M g M (O M M W W O O t` O N N (O N 7 O) (O OD t` p M O I- w w M O I- m m U �O 7 0 w I- t` N O t` w w m 0 1� m m d N N 7 7 7 N N 7 7 7 N N 7 7 7 U W I� N v i0 LL p W W K m m N N N I- 7 m N m 0 0 W W x m 0) 7 7 7 w 0) 7 w w w m m 1� r W y 0w N N N N N M M M M M 7 7 M 7 7 0w 7 M M M M . 7 7 7 7 (O N N N N H N Y a a a a a a a a a a a a a a a h N Y N N N N N N N N N N N N N N N > 'C O U U co `o o o LL LL N C a0 a0 I� N (O M a0 M n n O) (O (O ° a N 7 a0 M (O O 7 N a n (O O m (n C m N 0 M M m m 0 I- (o N (o O cq r y C M 0) w M M O (0 7 I� r O M O W (0 W 6 N 0 6 O) t0 7 M 0 0 aD O m W I(1 y 6 6 6 N N O r m 0 m 0 W 0I a a W M M N I- N O I- N M n n (p t0 a a W M O O M (O N 7 N M M N w O o N W 7 7 (0 M M q q O Il O M M 7 OD t` W (O (O O q cq M M I� O l0 I� OD N 0) M U O t0 N O) O) O) t0 N O O O I� M O U O op (M O O) O) O) 7 O O) 7 N N j p CI H � 7 7 M M M 7 7 7 7 7 7 7 7 7 7 H � N N N 7 7 N N N N N N N N N N m 'O J Q Q M p C U Z W W x M N N (O M 0 0 0 7 M M M Z cq 00 0o m m rn rn rn m rn o o rn rn rn a, rn cq cq cq cq O g m m m . . 0 0 0 FF N Y M M M M M M M M M M 7 7 M M M F N Y 7 7 7 7 7 N 7 7 7 7 N N N N N "O N W W W U OD N m m N LL O N W N W N O N O Z m t N O O N ? O) N O) M 7 (O M O M Z v t O O M O) N O O N a0 O N (O O) O) N LL O C (O M O cq N O M — I� t` M I� O O) C 7 (O C M. M 3. w N N I� O O I� I� o0 Oca 0Nj W (0 M N 0) 06 L0 7 N N 6 Il O 7 M G ON! W N 0 0) w N 7 M 7 7 N t0 7 (0 N W N C Z m N M M M 7 N M M 7 7 N M M 7 7 Z y M 7 M 7 N M 7 7 N N M 7 7 N N W U U 2 ca a cli °c 3 -o w eL W O M M 7 N V 0 M O O M O m p, 1� O M N V w I� M O M M M m N L Y C W W N O M V N M (O N 1l r M M 0 m. W W M O (0 M I� M N N (0 M 7 1l r O N C O H V 7 7 7 7 7 7 7 7 7 N 7 7 7 7 O N N N N 10 N N N N O N N N N W N O 01, S o. W I- O O r m m m m m M M M W W x M N OD r r w M w w w w M w M M N o. 'O 0w . 7 7 7 7 ( N N N N (0 (O (O (O (O F N Y ri M M M M M o E O .0 > CL U 00 W 0 7 N I� O) N O) 7 0 N N N 0) M A r O r N M O O O 00 7 00 O a n �j LL n >, C N N 0) w g q m 0 w w M I' M. 0) C N r OD N M N OD O m 0) N N M N (tl_ y W In W I- 7 N O N 06 (0 l0 7 7 O w I` 0 m. In W M O 6 7 6 7 N 6 6 6 I' 6 06 06 W pp m ,n N M M 7 7 N M M 7 7 M M M 7 7 pp m ,n M 7 7 7 N M 7 7 N N M 7 7 N N L 00 LL 0) c rL rL p O « 0 0 3 W W FO m m M V 0 V O O N O O M M M M O M O W M O 0 V pEL W W aD M O N M (O O Il O O O M M M W W t` O OD N (O M I- O N M N 7 M N .«d Y U U O 1� 7 M N N OD 7 7 7 M OD N N N U O N O N N 7 (O O (O 10 w 1� r OD OD W 0) 0 C H N 7 7 7 7 N 7 7 7 7 N 7 7 7 7 w w N N N (0 (0 N N N (0 (0 N N N 0 'W o o m O C U C O N O (O (0 (0 0 1- 7 7 7 w N N N N W W x O) M O) OD r m 7 m m m m 7 0) 0 0 m y W N �V O `♦.� N M N N N N M M M M M `J.� O O O O O O O O N N N N U F N Y ri ri ri ri ri ri ri ri ri ri ri ri ri ri ri F N Y v a ri ri ri a a a a a a a a a a � a�i o� o d r'`] o V'm 3 c a V m N O O ` Ol Ol m LL U r C C O (0 M m O N M V O 7 M M N V M M V O O 1� w O N N w M O o N W C 7 OD t` N M 7 W O cq N M (0 7 I- M w F- 7 7 (O (0 'V 500 O W 3 1() W M IO M 7 O) Il 10 7 (O 6 06 1` N: N W V N O (O (O N M 7 OD OD OD O O O W n (n N M M 7 7 N M M 7 7 M M M 7 7 n 0) M 7 7 m m M 7 7 m m M 7 7 w w 0-C C p d .0 U 0 "O W O � �O N 5 N C N U) O r w O O. N 7 W 7 V 1� O O O M M t` 0 7 O. O M 7 7 M M w O aD O aD -a C - «� W W M m 0 7 m — M w (0 M 1- 0) 7 00 I- W W M O. . (. (0 q cq 7 q In In (O (O m W O W W N M ta0 � (p V V V V (f N 7 7 7 N N 7 7 7 O O N N N O O N N N r O O O O 0) W 0 UO C O oLL Fo d Ca 's A _ m yv om o('0 N N 7 N I�m N 7 N I�m N 7 N 1�m (,� y CO, p W Q m U N o ro r v o ro r v o ro r Q m3 U N of w 0 v o ro r v o w 0 d d OE d A W LL N I� M N r N r M N r N r M N r W LL N r M N r N r M N r N r M N r y 0-- W O C Q ° r O O O N I� O O O N 1� O O O N Q 1 0 1 0 N 1� 1 0 1 0 1 0 N N a C Q A O O °Y E wc N a 0 0 0 a 0 0 o W a W U a U N N �m Lu H A �30 W Z 13 CONDENSER ONLY RATINGS SST CONDENSER ENTERING AIR TEMPERATURES°F(°C) °F(°C) 55(12.78) 65(18.33) 75(23.89) 85(29.44) 95(35.0) 105(40.56) 115(46.11) 125(51.67) 30 TCG 16.60 15.60 14.70 13.80 12.90 12.00 11.10 10.10 SDT 68.50 78.00 87.50 97.00 106.50 116.00 125.40 134.70 KW 0.76 0.87 0.99 1.11 1.25 1.40 1.59 1.80 35 TCG 18.30 17.20 16.30 15.30 14.30 13.30 12.30 11.20 (167) SDT 69.70 79.20 88.70 98.20 107.60 117.00 126.30 135.50 KW 0.76 0.87 0.99 1.11 1.25 1.41 1.59 1.80 40 TCG 20.00 19.00 17.90 16.90 15.80 14.70 13.60 12.40 (4.44) SDT 71.10 80.50 89.90 99.40 108.70 118.00 127.20 136.30 KW 0.77 0.88 0.99 1.11 1.25 1.41 1.59 1.80 45 TCG 22.00 20.80 19.70 18.50 17.40 16.20 14.90 13.60 (7.22) SDT 72.50 81.90 91.30 100.60 109.80 119.00 128.20 137.20 KW 0.77 0.88 0.99 1.12 1.26 1.41 1.59 1.80 50 TCG 24.00 22.80 21.60 20.40 19.10 17.80 16.40 15.00 (10.0) SDT 74.00 83.40 92.60 101.90 111.00 120.10 129.20 138.20 KW 0.77 0.88 0.99 1.12 1.26 1.41 1.59 1.80 55 TCG 26.30 25.00 23.60 22.30 20.90 19.50 18.00 16.40 (12.78) SDT 75.60 84.80 94.10 103.20 112.30 121.30 130.30 139.20 KW 0.78 0.88 1.00 1.12 1.26 1.42 1.60 1.80 30 TCG 21.40 20.20 19.00 17.80 16.60 15.40 14.20 12.90 (-1.11) SDT 71.90 81.30 90.70 100.00 109.30 118.50 127.70 136.80 KW 1.01 1.15 1.30 1.46 1.64 1.85 2.09 2.36 35 TCG 23.50 22.20 20.90 19.60 18.30 17.00 15.60 14.20 (167) SDT 73.50 82.80 92.10 101.30 110.50 119.60 128.70 137.70 KW 1.02 1.16 1.30 1.47 1.65 1.86 2.09 2.37 40 TCG 25.70 24.40 23.00 21.60 20.20 18.70 17.20 15.60 (4.44) SDT 75.10 84.30 93.50 102.60 111.80 120.80 129.80 138.80 KW 1.02 1.16 1.31 1.47 1.66 1.86 2.10 2.38 45 TCG 28.20 26.70 25.20 23.70 22.10 20.50 18.90 17.10 (7.22) SDT 76.70 85.90 95.00 104.10 113.10 122.10 131.00 139.80 KW 1.03 1.17 1.32 1.48 1.66 1.87 2.11 2.39 50 TCG 30.80 29.20 27.50 25.90 24.20 22.40 20.60 18.70 (10.0) SDT 78.50 87.50 96.60 105.60 114.60 123.40 132.20 140.90 KW 1.04 1.18 1.32 1.49 1.67 1.88 2.12 2.39 55 TCG 33.60 31.80 30.10 28.30 26.40 24.50 22.40 20.30 (12.78) SDT 80.30 89.30 98.30 107.20 116.10 124.90 133.50 142.00 KW 1.05 1.18 1.33 1.50 1.68 1.89 2.13 2.40 30 TCG 27.20 25.80 24.40 22.90 21.40 19.70 17.90 16.00 (_1.11) SDT 69.90 79.20 88.60 98.00 107.30 116.60 125.80 134.80 KW 1.22 1.39 1.57 1.77 2.00 2.27 2.58 2.94 35 TCG 30.10 28.50 27.00 25.40 23.70 21.90 20.00 17.90 (167) SDT 71.20 80.60 89.90 99.20 108.50 117.70 126.80 135.80 KW 1.22 1.40 1.58 1.78 2.01 2.28 2.58 2.94 40 TCG 33.10 31.40 29.70 28.00 26.20 24.30 22.20 20.00 (4.44) SDT 72.70 82.00 91.20 100.50 109.70 118.90 127.90 136.90 KW 1.23 1.41 1.59 1.80 2.03 2.29 2.59 2.94 45 TCG 36.50 34.50 32.70 30.80 28.80 26.80 24.50 22.10 (7.22) SDT 74.30 83.50 92.70 101.90 111.00 120.10 129.10 137.90 KW 1.25 1.43 1.61 1.82 2.05 2.31 2.60 2.95 50 TCG 40.00 37.90 35.80 33.80 31.60 29.40 27.00 24.40 (10.0) SDT 76.00 85.10 94.20 103.40 112.40 121.40 130.30 139.00 KW 1.27 1.45 1.64 1.84 2.07 2.33 2.62 2.95 TCG 43.80 41.40 39.20 36.90 34.60 32.10 29.50 26.70 55 SDT 77.90 86.90 95.90 104.90 113.90 122.80 131.50 140.20 (12.78) KW 1.29 1.47 1.66 1.87 2.09 2.35 2.64 2.97 See notes on page 15 14 CONDENSER ONLY RATINGS CONTINUED SST CONDENSER ENTERING AIR TEMPERATURES°F(°C) °F(°C) 55(12.78) 65(18.33) 75(23.89) 85(29.44) 95(35.0) 105(40.56) 115(46.11) 125(51.67) 30 TCG 31.40 29.80 28.20 26.40 24.60 22.70 20.60 18.50 (-1.11) SDT 68.70 78.10 87.50 96.80 106.20 115.50 124.70 134.00 KW 1.48 1.69 1.91 2.14 2.40 2.69 3.04 3.44 35 TCG 34.70 32.90 31.10 29.20 27.20 25.10 22.80 20.50 (167) SDT 70.00 79.30 88.60 97.90 107.20 116.40 125.60 134.80 7 KW 1.48 1.70 1.91 2.15 2.41 2.70 3.05 3.45 40 TCG 38.20 36.20 34.20 32.10 29.90 27.60 25.20 22.60 (4.44) SDT 71.30 80.50 89.80 99.10 108.30 117.40 126.50 135.60 KW 1.49 1.70 1.92 2.16 2.42 2.72 3.06 3.45 45 TCG 42.00 39.80 37.60 35.30 32.90 30.30 27.70 24.80 (7.22) SDT 72.80 81.90 91.10 100.30 109.40 118.50 127.50 136.40 KW 1.50 1.72 1.94 2.18 2.44 2.73 3.07 3.46 50 TCG 46.00 43.60 41.10 38.60 36.00 33.20 30.20 27.20 (10.0) SDT 74.40 83.40 92.50 101.60 110.60 119.60 128.50 137.30 KW 1.52 1.74 1.96 2.20 2.46 2.75 3.08 3.47 55 TCG 50.20 47.60 44.90 42.10 39.20 36.20 32.90 29.60 (12.78) SDT 76.10 85.00 94.00 103.00 111.90 120.80 129.50 138.20 KW 1.54 1.76 1.98 2.22 2.48 2.77 3.10 3.48 30 TCG 41.50 39.50 37.40 35.40 33.20 30.80 28.20 25.40 (_1.11) SDT 73.40 82.60 91.90 101.20 110.40 119.50 128.60 137.50 KW 2.05 2.30 2.57 2.87 3.21 3.60 4.05 4.56 35 TCG 45.70 43.40 41.20 38.90 36.50 33.90 31.10 28.10 (167) SDT 75.10 84.30 93.40 102.60 111.70 120.80 129.70 138.60 KW 2.08 2.33 2.60 2.90 3.24 3.63 4.08 4.60 40 TCG 50.10 47.70 45.20 42.70 40.10 37.20 34.20 30.90 (4.44) SDT 77.00 86.00 95.10 104.10 113.20 122.10 131.00 139.70 KW 2.12 2.36 2.63 2.93 3.27 3.67 4.12 4.64 45 TCG 54.80 52.20 49.50 46.70 43.80 40.70 37.40 33.80 (7.22) SDT 78.90 87.80 96.80 105.80 114.70 123.50 132.20 140.80 KW 2.15 2.39 2.66 2.96 3.31 3.71 4.16 4.69 50 TCG 59.90 56.90 54.00 51.00 47.80 44.40 40.70 36.80 (10.0) SDT 80.90 89.80 98.60 107.50 116.30 125.00 133.60 142.00 KW 2.19 2.43 2.70 3.00 3.34 3.74 4.20 4.72 55 TCG 65.20 62.00 58.80 55.40 51.90 48.20 44.20 39.90 (12.78) SDT 83.10 91.80 100.50 109.30 117.90 126.50 134.90 143.20 KW 2.24 2.47 2.73 3.03 3.38 3.78 4.24 4.76 0.0 30 TCG 53.00 50.30 47.70 45.10 42.40 39.40 36.00 32.40 (-1.11) SDT 76.00 85.10 94.30 103.50 112.70 121.70 130.60 139.40 KW 2.59 2.90 3.23 3.61 4.03 4.52 5.08 5.71 35 TCG 58.30 55.30 52.50 49.70 46.60 43.30 39.70 35.70 (167) SDT 78.00 87.00 96.10 105.20 114.20 123.10 131.90 140.60 KW 2.64 2.94 3.28 3.65 4.08 4.58 5.14 5.78 40 TCG 63.90 60.70 57.60 54.50 51.10 47.50 43.60 39.30 (4.44) SDT 80.00 88.90 97.90 106.90 115.80 124.70 133.30 141.90 KW 2.69 2.99 3.32 3.70 4.14 4.63 5.20 5.84 45 TCG 70.00 66.50 63.10 59.60 55.90 51.90 47.60 42.90 (7.22) SDT 82.20 91.00 99.90 108.80 117.60 126.30 134.80 143.20 KW 2.74 3.04 3.38 3.76 4.19 4.69 5.27 5.91 50 TCG 76.40 72.60 68.80 65.00 60.90 56.50 51.80 46.70 (10.0) SDT 84.60 93.30 102.00 110.70 119.40 127.90 136.30 144.50 KW 2.80 3.10 3.43 3.81 4.25 4.76 5.33 5.97 TCG 83.30 79.10 74.90 70.60 66.10 61.30 56.10 50.60 55 SDT 87.00 95.60 104.20 112.80 121.20 129.60 137.80 145.80 (12.78) KW 2.86 3.15 3.49 3.87 4.31 4.82 5.39 6.04 *AHRI listing applies only to systems shown in Combination Ratings table. KW - Outdoor Unit Kilowatts Only. SDT - Saturated Temperature Leaving Compressor(°F) SST - Saturated Temperature Entering Compressor(°F/°C) TCG - Gross Cooling Capacity(1000 Btuh) 15 GUIDE SPECIFICATIONS AIR-COOLED,SPLIT-SYSTEM AIR CONDITIONER 124ANS GENERAL 1-1/2 TO 5 NOMINAL TONS System Description — Condenser fan motors will be totally enclosed,1-phase Outdoor-mounted,air-cooled, split-system air conditioning unit type with class B insulation and permanently lubricated suitable for ground or rooftop installation. Unit consists of a bearings.Shafts will be corrosion resistant. scroll-type hermetic compressor, an air-cooled coil, — Fan blades will be statically and dynamically balanced. propeller-type condenser fan, and a control box. Unit will — Condenser fan openings will be equipped with coated discharge supply air horizontally as shown on contract drawings. steel wire safety guards. Unit will be used in a refrigeration circuit to match up to a Compressor packaged fan coil or furnace. — Compressor will be a scroll-type,hermetically sealed. Quality Assurance — Compressor will be mounted on rubber vibration — Unit will be rated in accordance with the latest edition isolators. of AHRI Standard 210. Condenser Coil — Unit will be certified for capacity and efficiency, and l — Condenser coil will be air cooled. listed in the latest AHRI directory. — Unit construction will comply with latest edition of — Coil will be constructed of aluminum fins mechanically ANSI/ASHRAE and with NEC. bonded to copper tubes which are then cleaned, — Unit will be constructed in accordance with UL dehydrated,and sealed. standards and will carry the UL label of approval.Unit Refrieeration Components will have c-UL approval. — Refrigeration circuit components will include — Unit cabinet will be capable of withstanding Federal liquid-line front-seating shutoff valve with sweat Test connections, vapor-line front-seating shutoff valve Method Standard No. 141 (Method 6061) 500-hr salt with sweat connections, system charge of Puron@ spray test. (R-410A)refrigerant,and compressor oil. — Air-cooled condenser coils will be leak tested and — Unit will be equipped with high-pressure switch, low pressure tested pressure switch and filter drier for Puron refrigerant. — Unit constructed in IS09001 approved facility. Operating Characteristics Delivery,Storage,and Handling — The capacity of the unit will meet or exceed Btuh at a suction temperature of °F/°C. The — Unit will be shipped as single package only and is power consumption at full load will not exceed stored and handled per unit manufacturer's kW recommendations. — Combination of the unit and the evaporator or fan coil Warranty(for inclusion by specifying engineer) unit will have a total net cooling capacity of — U.S.and Canada only. Btuh or greater at conditions of CFM entering PRODUCTS air temperature at the evaporator at °F/°C wet bulb and °F/°C dry bulb, and air entering the Equipment unit at °F/°C. — Factory assembled, single piece, air-cooled air — The system will have a SEER of Btuh/watt or conditioning unit. Contained within the unit enclosure greater at DOE conditions. is all factory wiring, piping, controls, compressor, Electrical Requirements refrigerant charge Puron@ (R-410A), and special features required prior to field start-up. — Nominal unit electrical characteristics will be v, Unit Cabinet single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of v — Unit cabinet will be constructed of galvanized steel and to V. bonderized. — Nominal unit electrical characteristics will be v, Fans three phase, 60 hz. The unit will be capable of — Condenser fan will be direct-drive propeller type, satisfactory operation within voltage limits of v discharging air horizontally. to V. — Unit electrical power will be single point connection. — Control circuit will be 24v. Special Features Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. 16 Copyright 2015 Bryant Heating&Cooling Systems• 7310 W.Morris St.• Indianapolis,IN 46231 Edition Date:01/15 Catalog No:PDS124ANS-01 Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. Replaces:New 17 � CITY OF ARLINGTON 238 N. OLYMPIC AVE- ARLINGTON, WA. 95223 PHONE; (360)403-3551 BUILDING PERMIT Address:526 N French Avenue Parcel#:0 1119852600200 Permit 0:1562 OWNER Valuation:0.00 APPLICANT CONTRACTOR Name:SWANSON KARLA J Name:Black[.ion HVAC Address:526 B FRENCH ST NE Names Black Lion Heating and Air Conditioning Address:)1001 118th Place NE Address: 11001 118th Place NG City,State Zip:ARLINGTON,WA 98223 City,State Zip:Kirkland,WA 98033 Phone: City.State 7,ip:Kirkland,WA 98033 Phone:425-814-3944 Phone:425-814-3944 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Black Lion Heating and Air Conditioning Name: Address: 11001 118th Place NE Address: City,State,Zip:Kirkland,WA 98033 City,State,Zip: Phone:425-814-3944 LIC#:BLACKLI1873 Phone: QQ E:{P: I!/l8/2017 LIC##7: EXY: JOB DESCRIPTION PERMTT'TYPE Residential Mechanical CODE YEAR: 2015 STORIES: 2 CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND S7ATF,LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF'I HE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 1827. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/IIER DEPUI'Y AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL.INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF PANCY HAS BEEN GRANTED. IBCI l0/1RC110. SALES T s tax relating to construction and construction materials in the(-iq of Nrliokt n must be rgpnrted on your sales tax return form and t I. � — Signat Print Name Date Rcicnsed By Date CONDITIONS Approve s Submit stallation requirements: 3" concrete pad with seismic bracing attached to pad, provide electrical disconnect, lines shall be insulated -the use of adhesive tape is not permitted. THIS PERMIT AUT)lORIZS ONLY THE WORK NOTED THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY ANY CONSTRUCTION ON TI[E PUBLIC DOMAIN(CURBS.SIDEWALKS,DRIVEWAYS,MARQUEES,ETC i WILL REQUIRE SEPARATE.PERMISSION PERMIT FEES Date Description 7/21/2017 A/C Unit Fee Amount 7/21/2017 Mechanical Permit Base Fee $25.00 7/21/2017 Processingrrechnology Fee $25.00 $25.00 Total Due: $75.00 Total Payment: $75 00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Community and Economic Development Building Division INSPECTION RECORD SHALL REMAIN AT JOB Building construction shall not commence until permit SITE holder or agent has posted this Inspection Record Card in a conspicuous place on the premises. OWNER: Karla Swanson CONTRACTOR: Black Lion Heating &Air Conditioning JOB ADDRESS:526 N French Avenue OWNERADDRESS: 526 N French Avenue USE of BUILDING: SFR PLAT NAME: Description of Work: Mechanical/Install A/C LOT# PERMIT NO: 1562 S rinklered:NO CONDITIONS: See Permit DATE ISSUED:7.21.2017 TYPE GROUP DEPARTMENT INSPECTION DATE DATE PASS FAIL INITIALS FOOTING BUILDING FOUNDATION INSPECTION LINE UNDERFLOOR (360)403-3417 SHEARWALL PLUMBING(groundwork) GAS PIPING(groundwork) ROUGH PLUMBING ROUGH GAS PIPING ROUGH HEATING&VENTILATION FRAMING INSULATION WALLBOARD(SHEAR/RATING) ROOF DRAINAGE DEVELOPMENT STORM INFILTRATION SERVICES GRADING INSPECTION LINE CURB GUTTER&SIDEWALK (360)403-3417 LANDSCAPE DRIVEWAY UTILITIES SIDE SEWER INSPECTION LINE SEWER CLEANOUT/FINAL (360)403-3508 WATER SERVICE INSPECTION WATER SERVICE FINAL CROSS CONNECTION FINAL (360)403-3417 FINAL INSPECTION All sections must be signed off prior to final inspection Electrical must be signed off prior to final inspection COMMENTS: CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:526 N French Avenue Permit#:1562 Parcel#:01119852600200 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:SWANSON KARLA J Name:Black Lion HVAC Name:Black Lion Heating and Air Conditioning Address:526 B FRENCH ST NE Address:11001 118th Place NE Address: 11001 118th Place NE City,State Zip:ARLINGTON,WA 98223 City,State Zip:Kirkland,WA 98033 City,State Zip:Kirkland,WA 98033 Phone: Phone:425-814-3944 Phone:425-814-3944 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Black Lion Heating and Air Conditioning Name: Address: 11001 118th Place NE Address: City,State,Zip:Kirkland,WA 98033 City,State,Zip: Phone:425-814-3944 Phone: LIC#:BLACKLH873QQ EXP: 11/18/2017 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: 2 CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials i hwlT �it.r-ffiliflin t n must be reported on your sales tax return form and coded City of Arlington#3101. �� / Signature Print Name Date Released By Date CONDITIONS Approved as submitted. Installation requirements: 3" concrete pad with seismic bracing attached to pad, provide electrical disconnect, lines shall be insulated-the use of adhesive tape is not permitted. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 7/21/2017 A/C Unit $25.00 7/21/2017 Mechanical Permit Base Fee $25.00 7/21/2017 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $75.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Community and Economic Development , Building Division INSPECTION RECORD SHALL REMAIN AT JOB Building construction shall not commence until permit SITE holder or agent has posted this Inspection Record Card in a conspicuous place on the premises. OWNER: Karla Swanson CONTRACTOR: Black Lion Heating & Air Conditioning JOB ADDRESS:526 N French Avenue OWNERADDRESS: 526 N French Avenue USE of BUILDING: SFR PLAT NAME: Description of Work: Mechanical/Install A/C LOT# PERMIT NO: 1 562 Sprinklered:No CONDITIONS: See Permit DATE ISSUED:7.21.2017 TYPE GROUP DEPARTMENT INSPECTION DATE DATE PASS FAIL INITIALS FOOTING BUILDING FOUNDATION INSPECTION LINE UNDERFLOOR (360)403-3417 SHEARWALL PLUMBING (groundwork) GAS PIPING(groundwork) ROUGH PLUMBING ROUGH GAS PIPING ROUGH HEATING&VENTILATION FRAMING INSULATION WALLBOARD(SHEAR/RATING) ROOF DRAINAGE DEVELOPMENT STORM INFILTRATION SERVICES GRADING INSPECTION LINE CURB GUTTER&SIDEWALK (360)403-3417 LANDSCAPE DRIVEWAY UTILITIES SIDE SEWER INSPECTION LINE SEWER CLEANOUT/FINAL (360)403-3508 WATER SERVICE INSPECTION WATER SERVICE FINAL CROSS CONNECTION FINAL (360)403-3417 FINAL INSPECTION All sections must be signed off prior to final inspection Electrical must be signed off prior to final inspection COMMENTS: CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA.98223 PHONE; (360)403-3551 _ BUILDING PERMIT Address:576 N French Avenue — ---- Parcel k:0 1119832600200 Permit#-.1562 -- OwNER Valuation:0,00 APPLICANT CONTRACTOR Name:SWANSON KARLA J Name:Black Lion HVAC Address:526 B FRENCH ST NE Name:Black 1 Heating and Air Conditioning Name: 118th Place NE Address:liOU 1 11 8th Place NE City,State Zip:ARLINGTON,WA 98223 City,State"Zip:Kirkland,WA 98033 Phone: City,StateZip:Kirkland,WA 98033 Phone:425-814-3944 Phone:425-814-3944 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Black Lion Heating and Air Condiloning Address:11001 I I801 Place NE Name: City,State,Zip:Kirkland,WA 98033 Address: Phone:425-814-3944 City,State,Zip: LIC#:BLACKLHR73 Phone: QQ EXP: 1 1/1 81201 7 LIC N: FXP: JOB DESCRIPTION _ PERMIT'fYPE: Residential Mechanical CODE YEAR: 2015 STORIES: 2 CONST.TYPE: DWELLING UNITS: I OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL !AGREI:TO COMPLY WITH CITY AND ST A'1'[i LAWS REGULATING C(Nd5'rRl11171 11 N AND IN DOING TILL'WORK AUTI IORIZ(iD rH1:REBY;NO PERSON WILL BE EMPLOYED 1N VIOLATION OP T'HE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCF AND RCW 18 27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE,BUILDING OFFICIAL OR HIS/IFER DEPUTY AND ALL FEES ARE,PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF PANCY HAS BEEN GRANTED, IBC 110/IRC 110. SA .ES T tar relating to construction and construction materials 4 the tatg of A'rhnLtltm must be rupnneJ on your sales tax return form ind t 1. Print Name Date Released By Date CONDITIONS Approve S submit stallation requirements: 3"concrete pad with seismic bracing attached to pad, provide electrical disconnect, lines shall be insulated -the use of adhesive tape is not permitted. THIS PERMIT At1TTIORIZS ONI.Y THE WORK NOmiU THIS PERMIT COVERS WORK TO 1IF DONE ON PRIVATE PROPERTY ONLY ANY CONSTRUCTION ON m1E PUBLIC DOMAIN(CURBS.SIDEWALKS,DRIVEWAYS,MARQUIMS,L•TC I WILL R1iQUIRL SEPARATES PINUMISSION _ PERMIT FEES Date Description 7/21/2017 A/C Unit Fee Amount 7/21/2017 Mechanical Permit Base Fee $25.00 7/21/2017 Processing/Technology Fee S25.00 $25,00 Total Due; S75.00 Total Payment: $75.00 Balance one: 80,00 CALL FOR INSPECTIONS BUILDING(3(0)4113-341' When calling for an inspection please leave the following informatinn: Community and Economic Development Building Division INSPECTION RECORD SHALL REMAIN AT JOB Building construction shall not commence until permit SITE holder or agent has posted this Inspection Record Card in a conspicuous place on the premises. OWNER: Karla Swanson CONTRACTOR: Black Lion Heating &Air Conditioning Jos ADDRESS:526 N French Avenue OWNER ADDRESS: 526 N French Avenue USE of BUILDING: SFR PLAT NAtL Description of work: Mechanical/Install A/C LOT# PERMIT NO: 1�6` No CONDITIONS: See Permit DATE ISSUED:7.21.2017 TYPE GROUP DEPARTMENT INSPECTION FOOTINGDATE DATE PASS FAIL INITIALS BUILDING FOUNDATION INSPECTION LINE UNDERFLOOR (360)403-3417 SHEARWALL PLUMBING(groundwork) GAS PIPING(groundwork) ROUGH PLUMBING ROUGH GAS PIPING ROUGH HEATING&VENTILATION FRAMING INSULATION WALLBOARD(SHEAR/RATING) ROOF DRAINAGE DEVELOPMENT STORM INFILTRATION SERVICES GRADING INSPECTION LINE CURB GUTTER&SIDEWALK (360)403-3417 LANDSCAPE DRIVEWAY UTILITIES SIDE SEWER INSPECTION LINE SEWER CLEANOUT/FINAL (360)403-3508 WATER SERVICE INSPECTION WATER SERVICE FINAL CROSS CONNECTION FINAL (360)403-3417 FINAL INSPECTION All sections must be signed off prior to final inspection Electrical must be signed off prior to final inspection COMMENTS. ° CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:526 N French Avenue Permit#:1562 Parcel#:0 1119852600200 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:S WANSON KARLA J Name:Black Lion HVAC Name:Black Lion Heating and Air Conditioning Address:526 B FRENCH ST NE Address:1100 1 118th Place NE Address:11001 118th Place NE City,State Zip:ARLINGTON,WA 98223 City,State Zip:Kirkland,WA 98033 City,State Zip:Kirkland,WA 98033 Phone: Phone:425-814-3944 Phone:425-814-3944 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Black Lion Heating and Air Conditioning Name: Address: 11001 118th Place NE Address: City,State,Zip:Kirkland,WA 98033 City,State,Zip: Phone:425-814-3944 Phone: LIC#:BLACKLH873QQ EXP: 11/18/2017 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: 2 CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRCI10. SALES TAX NOTICE:Sales tax relating to construction and construction materials i F;iiy 'Fin n must be ported on your sales tax return form and coded City of Arlington#3101. C Signature Print Name Date Rele By Date CONDITIONS Approved as submitted. Installation requirements: 3" concrete pad with seismic bracing attached to pad, provide electrical disconnect, lines shall be insulated -the use of adhesive tape is not permitted. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 7/21/2017 A/C Unit $25.00 7/21/2017 Mechanical Permit Base Fee $25.00 7/21/2017 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $75.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit Information Date 7/21/2017 Permit Number 1562 Project Name Swanson Applicant Name Black Lion HVAC Applicant Address 11001 118th Place NE City,State,Zip Kirkland,WA 98033 Contact Brenda Lopez Phone 425-814-3944 Email brenda@blacklionhvac.com;info@blacklionhvac.com Permit Type Residential Mechanical Site Address 526 N French Avenue Valuation 0.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 0 Proposed Use Install A/C Assigned To Kristin Foster Property Information Owner Information Parcel#:01119852600200 SWANSON KARLA J SWANSON KARLA J 526 B FRENCH ST NE 526 FRENCH AVE UNIT B ARLINGTON,WA 98223 Contractors Contractor Name Primary Phone Email Contractor License License# Contact Type Black Lion Heating and Air 425-814- Labor and Conditioning Brenda Lopez:3944 nfo@blacklionhvac.co CONTRACTOR Industries BLACKLH873QQ Review DaEe=F Type Description I Target Date Completed Date Assigned To r Status 7/21/2017 Residential Mechanical -7/28/2017 (Rick Karns In Review Fees Fee Description Notes Amount A/C Uni 322.10.00.0 $25.0 Mechanical Permit Base Fe 322.10.00.0 $25 0 Processing/Technology Fe 341.43.00.021 $25.0 Total $75.0 Notes Date Note 7/21/2017 Out of City has expired.KF Uploaded Files Upload File Date File Uploaded B 7/21/2017 9:28:00 AM 1562 Specs Partl.pdf Foster, Kristin I x 7/21/2017 9:28:00 AM 1562 Specs Part3.pdf Foster,Kristin X 7/21/2017 9:28:00 AM 1562 Specs Part2.pdf Foster,Kristin x 7/21/2017 9:26:36 AM 1562 Application.pdf Foster,Kristin RESIDENTIAL MECHANICAL • 4 PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:526 N French Ave Project Description-AC add Owner: Karla Swanson Address: 526 N French Ave City:Arlington State'.WA Zip Code: 98223 Phone: 4253207762 Email:N/A Applicant: Black Lion HVAC Address: 11001 118TH PL NE City: Kirkland State WA Zip Code: 98033 Phone: 425-814-3944 Email: BRENDA@BLACKLIONHVAC.COM CONTRACTOR INFORMATION Contractor Name:BLACK LION HVAC Address: 11001 118TH PL NE City: Kirkland State WA Zip Code: 98033 License Number:BLACKLH873QQ Expiration: 11/17 Phone:425-814-3944 Email:INFO@BLACKLION H VAC.COM Received STAFF USE ON JUL 20 2017 Permit#: a7, Accepted by: Date: 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL (f`Ov PERMIT APPLICATION jM1' Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES ❑ Furnace (80+) Model # AFUE ❑ Heat Pump Model # AFUE HSPE AC Unit Model # Bryant 124 SEER 14 Freestanding Stove Fire Place Insert Ij Outdoor BBQ �l Gas Piping Solid-Fuel Appliance 1 � Other Gas Piping Information Not Applicable: Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances _c�t essacr,o�sr� Applicant Signature: Date: 07/20/2017 Applicant Printed Name: Brenda Lopez I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable,laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 7/21/2017 BLACK LION HEATING&A/C LLC �Fr�ni nn!,ul Search L&I \-7 rnrLre fldp M', L&i Safety Health Claims&Insurance 'nlarkplace Rights Trades&Licensing *110*4 Washington State Department of `J Labor & Industries BLACK LION HEATING &A/C LLC Owner or tradesperson 11001 118th PI NE KIRKLAND,WA 98033 Principals 425-814-39" BURGE,JASON ROBERT,PARTNER/MEMBER KING County WARD,BENJAMIN PATRICK,PARTNER/MEMBER BURGE,JASON ROBERT,MANAGER BURGE,JASON ROBERT,AGENT Doing business as BLACK LION HEATING&A/C LLC WA UBI No. Business type 603 615 990 Limited Liability Company Governing persons BENJAMIN PATRICK WARD JASON R BURGE; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. BLACKLH873QQ Effective—expiration 11/18/2013-11/18/2017 Bond Hartford Fire Ins Co $12,000.00 Bond account no. 52BSBHF4778 Received by L&I Effective date 06/24/2016 07101/2016 Expiration date Until Canceled Bond history Insurance Federated Mutual Ins Co $1,000,000.00 Policy no. 89167352 Received by L&I Effective date 06/05/2017 05/31/2017 Help us improve hftps://secure.ini.wa.gov/verify/Detail.aspx?UBI=603615990&LIC=BLACKLH873QQ&SAW= 1/2 7/21/2017 BLACK LION HEATING&A/C LLC Expiration date 08/01/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savin.9s No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&1 tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 525,786-01 Doing business as BLACK LION HEATING&AIR CO Estimated workers reported Quarter 1 of Year 2017"21 to 30 Workers" L&I account contact T7/JAN BENTLEY(360)902-4652-Email:STR0235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. ©Washington State Dept.of Labor&Industries.Use of this site is subject!o the laws of the state of Washington. Help us improve https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=603615990&LIC=BLACKLH873QQ&SAW= 2/2 �1 WITH PUROW REFRIGERANT 1-1/2 TO 55 NOMINALTONS Awe Product Data INDUSTRY LEADING atr,1'1 ui to n FEATURES/BENEFITS l�lll Energy Efficiency • .14 SEER/11.7-12.2 EER (Based on tested combinations) Sound • Levels as low as 66 dBA Design Features • Small footprint • DuraGuard- cabinet 6oPreferred TM —All steel cabinet construction �n _ —Mesh coil guard Reliability, Quality and Toughness Bryant air conditioners with Puron o refrigerant provide a • Scroll compressor collection of features unmatched by any other family of • Factory-supplied filter drier equipment. The 124ANS has been designed utilizing Bryant's Puron refrigerant.This environmentally sound refrigerant allows • High pressure switch you to make a responsible decision in the protection of the earth's • Low pressure switch ozone layer. • Accumulator NOTE: Ratings contained in this document are subject to • Line lengths up to 250'(76.2 m) change at any time. Always refer to the AI#RI directory (www.ahridircctory.orgJ for the most up-to-date ratings • Low ambient operation information. (down to -20°F/-28.9°C with low ambient accessories) Received JUL 21 2017 W r-407- MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 14 N N N A AN N N N N A/N AIN N A 1 2 4 A N S 0 3 6 0 0 0 A Product Tier SEER Variations Voltage Variations Cooling Open Open Open Series Family 2=Preferred 4=14 SEER S=Side Discharge N=208/230-1 S=Stan- Capacity O=Not O=Not O=Not A= 1 =AC P=208/230-3 dard Defined Defined Defined Original E=460-3 Seres CERTIFIED Ptiron. C UL US Use of the AHRI Certified TM Mark indicates a manufacturer's participation In the program For verification of certification fir individual products,go to w ..ahridirectory.org PHYSICAL DATA UNIT SIZE—SERIES(VOLTAGE) 18—A 24—A 30—A 36—A 48—A 60—A (N) (N) (N) (N,P,E) (N,P,E) (N,P,E) COMPRESSOR TYPE Scroll REFRIGERANT Puron®(R-410A) Charge Ib(kg) 6.40(2.90) 6.50(2.95) 8.60(3.90) 8.90(4.04) 9.00(4.08) 10.60(4.81) COND FAN Propeller Type,Direct Drive Air Discharge Horizontal Air City(CFM) 1285 1285 1900 2615 2615 2785 Motor HP 1/12 1/12 1/10 1/4 1/4 1/4 Motor RPM 800 800 800 800 800 800 COND COIL Face Area(Sq ft) 7.3 7.3 12.1 12.1 12.1 14.1 Fins per In. 20 20 20 20 20 20 Rows 2 2 2 2 2 2 Circuits 3 3 3 3 3 4 VALVE CONNECT.(In.ID) Vapor 5/8 3/4 3/4 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES*(In.OD) Rated Vapor* 5/8 3/4 3/4 1 7/8 7/8 1 1/8 Max Liquid Linet 3/8 *Units are rated with 25 fit(7.6 m)of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. Note: See unit Installation Instruction for proper installation. I See Liquid Line Sizing For Cooling Only Systems with Purun Refrigerant tables. 1 2 REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line Sizing and Maximum Total Equivalent Lengthst for Cooling Only Systems with Puron®Refrigerant: The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units. See Table below for liquid line sizing and maximum lengths: Maximum Total Equivalent Length Outdoor Unit BELOW Indoor Unit Liquid AC with Puron Refrigerant Maximum Total Equivalent Lengtht: Outdoor unit BELOW Indoor Size Liquid Line Line Vertical Separation It(m) Connection Diem. 0-5 6-10 11-20 21-30 31-40 41-50 51-W 61-70 71-W w/TXV 0-1.5 1.8-3.0 3.4-6.1 6.4-9.1 9.4-12.2 12.5-152 15.5-18.3 18.6-21.3 21.6-24.4 018 1/4 150 150 125 100 100 75 -- -- -- AC with 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 225* 150 Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 024 1/4 75 75 75 50 50 -- -- AC with 3/8 5/16 250* 250* 250* 250* 250* 225* 175 125 100 Puron 318 250* 250* 250* 250* 250* 250* 250* 250* 250* 030 1/4 30 -- -- -- -- -- -- -- AC with 3/8 5/16 175 225* 200 175 125 100 75 -- Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 036 5/16 175 150 150 100 100 100 75 -- -- AC with 3/8 Puron 3//8 250* 250* 250* 250* 250* 250* 250* 250* 250* 048 AC with 3/8 3/8 250* 250* 250* 250* 250* 250* 230 160 -- Puron _ o60 AC with 3/8 3/8 250* 250* 250* 225* 190 150 110 -- -- Puron * Maximum actual length not to exceed 200 It(61 m) t Total equivalent length accounts for losses due to elbows or fitting.See the Long Line Guideline for details. -- =outside acceptable range Maximum Total Equivalent Length Outdoor Unit ABOVE Indoor Unit Liquid AC with Puron Refrigerant Maximum Total Equivalent Lengtht: Outdoor unit ABOVE Indoor Size Liquid Line Line Vertical Separation it(m) Connection Diem. 25 26-50 51-75 76-100 101-125 12s-150 151-175 178-200 w/T .6 7.9-15.2 15.5-22.9 32-30.5 30.8-36.1 3e.4-a5. 46.0-53.3 63.8-61.0 018 1/4 175 250* 250* 250* 250* 250* 250* 250* AC with 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* Puron_ 3/8 250* 250* 250* 250* 250* 250* 250* 250* 024 1/4 100 125 175 200 225* 250* 250* 250* AC with 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 030 1/4 30 -- -- -- -- -- -- AC with 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 036 5/16 225* 250* 250* 250* 250* 250* 250* 250* AC with 3/8 Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 048 AC with 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250* Puron 060 — AC with 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250* Puron *Maximum actual length not to exceed 200 It(61 m) t Total equivalent length accounts for losses due to elbows or fitting.See the Long Line Guideline for details. -- =outside acceptable range 3 REFRIGERANT CHARGE ADJUSTMENTS Liquid Line Size Puron Charge oz/ft(g/m) 3/8 0.60(17.74) (Factory charge for lineset=9 oz/266.16 g) 5/16 0.40(11.83) 1/4 0.27(7.98) Units are factory charged for 15 ft(4.6 m)of 3/8"liquid line. The factory charge for 3/8"lineset 9 oz(266.16 g). When using other length or diameter liquid lines,charge adjustments are required per the chart above. Cbaraina formula: [(Lineset oz/ft x total length)—(factory charge for lineset)]=charge adjustment Example 1:System has 15 ft of line set using existing 1/4"liquid line. What charge adjustment is required? Formula: (.27 oz/ft x 15ft)—(9 oz)=(4.95)oz. Net result is to remove 4.95 oz of refrigerant from the system Example 2: Systeiu has 45 11 of existhig 5/16"liquid lino.Wl1at is die ulia,ge adjustment? Formula: (.40 oz/ft.x 45ft)—(9 oz.)=9 oz. Net result is to add 9 oz of refrigerant to the system LONG LINE APPLICATIONS An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter,actual length of the tubing,and vertical separation between the indoor and outdoor units. For Air Conditioner systems,the chart below shows when an application is considered Long Line. AC WITH PURONS REFRIGERANT LONG LINE DESCRIPTION tt(m) Beyond these lengths,long line accessories are required Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor No accewo needed within allowed No accewor;es needed w;th;n'll.^.4 1/4 lengths c lengths c 175(53.3) 5/16 120(36.6) 50(15.2)vertical or 120(36.6)total 120(36.6) 3/8 80(24.4) 35(10.7)vertical or 80 24.4)total 80(24.4) Note: See Long Line Guideline for details VAPOR LINE SIZING AND COOLING CAPACITY LOSS LONG LINE APPLICATION: An application is considered vertical separation is 200 ft. (60.96 m) when outdoor unit is "Long line" when the total equivalent tubing length exceeds 80 above indoor unit, and up to 80 ft.(24.38 m)when the outdoor ft.(24.38 m)or when there is more than 20 ft. (6.09 m)vertical unit is below the indoor unit.Refer to Accessory Usage Guideline separation between indoor and outdoor units.These applications below for required accessories. See Longline Application require additional accessories and system modifications for Guideline for required piping and system modifications. Also, reliable system operation. The maximum allowable total refer to the table below for the vapor tube diameters based on the equivalent length is up to 250 ft. (76.2 m). The maximum total length to minimize the cooling capacity loss. Vapor Line Sizing and Cooling Capacity Losses—Puron®Refrigerant 1-Stage Air Conditioner Applications Unit Vapor Line Cooling Capacity Loss(%) Liquid Line Total Equivalent Line Length ft.(m) Nominal Diameters 26-50 51-00 81-100 101-125 126-150 151-175 176-200 201-225 226-250 Size final Diameters is OD) (in.OD) .9-16.2 1SA-24A (24.7-30.5) (30.8-38.1) 38.4-45.7) (46.0-83.3) (53.6-61.0) (61.3-68.8 68.9-76.2 016 1/2 1 2 1 3 5 6 7 a 9 11 1 Stage AC with 3/8 5/8 0 1 1 1 1 2 2 2 3 3 Puron 1 3/4 0 0 0 0 1 1 1 1 1 024 5/8 0 1 2 2 3 3 4 5 5 1 Stage AC with 3/8 3/4 0 0 1 1 1 1 1 2 2 Puron 7/8 0 1 0 0 0 0 1 1 1 1 030 5/8 1 2 3 3 4 5 6 7 6 1 Stage AC with 3/8 3/4 0 0 1 1 1 2 2 2 3 Puron 1 7/8 0 0 0 0 1 1 1 1 1 1 036 5/8 1 2 4 5 a 6 9 10 12 1 Stage 3/8 3/4 0 1 1 2 2 3 3 4 4 AC with Puron 7/8 0 0 0 1 1 1 1 2 2 048 3/4 0 1 2 3 4 5 5 6 7 1 Stage AC with 3/8 7/8 0 0 1 1 2 2 2 3 3 Puron 11/8 0 0 0 0 0 0 0 1 1 050 3/4 1 2 4 5 6 7 9 10 11 1 Stage AC with 3/8 7/8 0 1 1 2 2 3 4 4 5 5 Puron 11/8 0 0 0 1 1 1 1 1 1 Applications in this area may be long line and may have height restrictions. See the Res/dentlaf Piping and Long Line Guideline. 4 ACCESSORIES Unit Size(Voltage/Series) KIT NUMBER KIT NAME 018 024 030 036 036 036 048 048 048 060 060 080 (30) (30) (30) (30) (50) (80) (30) (50) (60) (30) (50) (60) KAACH1401AAA Crankcase Heater X X X X X KAACH1201AAA Crankcase Heater X X X X KAACH1501AAA Crankcase Heater X KAACH1901AAA Crankcase Heater X X KAAFT0101AAA Evaporator Freeze Stat X X X j X X X X X X X X X KAATD0101TDR Time Delay Relay X X X X X X X X X X X X KAAWS0101AAA Winter Start Kit X X X X X X X X X X X X KSALA0601AAA MotorMaster©230v X X X X X X X X X KSALA0901AAA MotorMaster®460v X X X 53DS-900———087 Wind Baffle X X 53DS-900———071 Wind Baffle X I X X X X X X 53DS-900———088 Wind Baffle X X X 53DS-900---075 Stacking Kit X X 53DS-900———076 Stacking Kit X X X X X X X X X X 53DS-900———077 Wall Mounting Kit X X 53DS-900———078 Wall Mounting Kit X X X X X X X X X X KAALP0401PUR Pressure Switch Kit X X X X X X X X X X X X KSASH2301COP Sound Blanket Kit X X X X X X KSASH2401COP Sound Blanket Kit X X X X X X KAALS0201LLS Solenoid Valve Kit X X X X X X X X X X X X KSAHS1501AAA Capacitor Relay Start X X X X X X Assist X=Accessory ACCESSORY THERMOSTATS PART NUMBER DESCRIPTION T6-WEM01 HousewiseTm Wi-Fi®thermostat T6-PRH01-A Programmable Relative Humidity Thermostat T6-PAC01 Programmable Thermostat T6-NRH01 Non-Programmable Relative Humidity Thermostat T6-NAC01 Non-Programmable Thermostat T2-WHS01 Wi-Fi®Thermostat T2-PAC01 Programmable Thermostat T2-NAC01 Non-Programmable Thermostat T2SNAC01 Non-Programmable Standard Screen Thermostat THERMOSTAT ACCESSORIES PART NUMBER DESCRIPTION THERMOSTATS USED WITH T6-EXP EXPO Card T6-Pxx,T6-Nxx TSTATXXSEN01-B Outdoor Air Temperature Sensor T6-Pxx,T6-Nxx TSTATXXCNV10 Thermostat Conversion Kit(4 to 5 wire)-10 pack All Bryant®branded thermostats TX-MBP01 Medium Decorative Backplate T2-Nxx TX-LBP01 Large Decorative Backplate T6-Pxx,T6-Nxx,T2-Pxx 5 ACCESSORY USAGE GUIDELINE REQUIRED FOR LOW—AMBIENT REQUIRED FOR REQUIRED FOR Accessory COOLING APPLICATIONS LONG LINE APPLICATIONS* SEA COAST APPLICATIONS (Below 551F/12.8°C) (Over 80 ft./24.38 m) (Within 2 miles/3.22 km) Bell Bearing Fan Motor Standard Standard Standard Compressor Start Assist Capacitor and Yes Yes No Relay Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Liquid Line Solenoid Valve No See Long-Line Application No Guideline Low Ambient Pressure Switch or MotorMaster®Controller Yes No No *For tubing line sets between 80 and 200 ft.(24.38 and 60.96 m) and/or 20 ft.(6.09 m)vertical differential,refer to Residential Split-System Longline Application Guideline. Accessory Description and Usage(Listed Alphabetically) 1.Ball-Bearing Fan Motor 4.Evaporator Freeze Thermostat A fan motor with ball bearings which permits speed reduction An SPST temperature-actuated switch that stops unit operation while maintaining bearing lubrication. when evaporator reaches freeze-up conditions. Usage Guideline: Usage Guideline: Required on all units when using MotorMaster® Required when low ambient kit has been added. 2.Compressor Start Assist-Capacitor and Relay 5.Low-Ambient Pressure Switch Kit Start capacitor and relay gives a "hard" boost to compressor A long life pressure switch which is mounted to outdoor unit motor at each start up. service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal tt� Usage Guideline-. order operating"g ltm �• Required for reciprocating compressors in the The control will maintain working head pressure at low-ambient following applications: temperatures down to 0°F(-18°C)when properly installed. Long line Usage Guideline: Low ambient cooling A Law-Ambient Pressure Switch or MotorMaster® Low-Ambient Controller must be used when cooling Hard shut off expansion valve on indoor coil operation is used at outdoor temperatures below 55°F Liquid line solenoid on indoor coil (12.8°C). Required for single-phase scroll compressors in the Suggested for all commercial applications. following applications: 6.MotorMaster Low-Ambient Controller Long line A fan-speed control device activated by a temperature sensor, Low ambient cooling designed to control condenser fan motor speed in response to the Suggested for all compressors in areas with a history of saturated condensing temperatures down to -20°F(-28.9*C),it low voltage problems. maintains condensing temperature at 100°F +/- 10°F (37.8°C 3.Crankcase Heater +/-6°C) An electric resistance heater which mounts to the base of the Usage Guideline: compressor to keep the lubricant warm during off cycles, A MotorMaster Low-Ambient Controller or Improves compressor lubrication on restart and minimizes the Low-Ambient Pressure Switch must be used when chance of liquid slugging. cooling operation is used at outdoor temperatures Usage Guideline: below 55°F(12.8°C). Required in low ambient cooling applications. Suggested for all commercial applications. Required in long line applications. Suggested in all commercial applications. 6 ELECTRICAL DATA U SERIES V/PH SIZE- OPER VOLTS* COMPR FAN MCA MAX FUSE**or (VOLTAGE) MAX MIN LRA RLA FLA CKTBRKAMPS 018-A N 56.3 9.0 0.50 11.8 20 024-A(N) 02.9 10.9 0.50 14.1 25 030-A(N) 73.0 14.1 0.70 18.3 30 036-A(N) 208/230/1 253 197 77.0 14.1 1.20 18.8 30 048-A(N) 124.0 18.5 1.20 24.3 40 060-A(N) 152.5 23.7 1.45 31.1 50 036-A(P) - 71.0 9.0 1.20 12.5 20 040-A(P) 208/230/3 253 197 83.1 13.7 1.20 18.3 30 060-A(P) 110.0 15.9 1.45 21.4 35 036-A E) 5.6 0.60 7.6 15 048-A(E) 460/3 506 414 41.0 6.2 0.60 8.4 1 15 060-A(E) 52.0 7.1 0.80 9.7 15 LEGEND: FLA -Full Load Amps HACR -Heating,Air Conditioning,Refrigeration LRA -Locked Rotor Amps NEC -National Electrical Code RLA -Rated Load Amps(compressor) * Permissible limits of the voltage range at which the unit will operate satisfactorily ** Time-Delay fuse. Complies with 2007 requirements of ASHRAE Standards 901 A-WEIGHTED SOUND POWER (dBA) Standard Typical Octave Band Spectrum(dBA,without tone adjustment) Unit Size Rating (dBA) 125 250 500 1000 2000 4000 8000 18 69 50.5 57.0 59.5 64.5 60.5 53.5 43.0 24 66 50.5 58.5 60.5 59.5 56.5 51.0 41.5 30 68 55.5 59.5 61.5 63.5 60.0 58.0 49.5 36 71 59.5 59.5 62.0 65.5 63.5 62.0 55.0 48 70 57.5 59.5 64.0 66.0 63.0 60.5 54.5 60 73 1 60.0 61-.5---r 64.5 67.0 66.0 65.5 58.0 NOTE: Tested in accordance with AHRI Standard 270-08(not listed in AHRI). A-WEIGHTED SOUND POWER (dBA) WITH ACCESSORY SOUND SHIELD Standard Typical Octave Band Spectrum(dBA,without tone adjustment) Unit Size Rating (dBA) 125 250 500 1000 2000 4000 8000 18 68 52.5 58.0 58.5 64.5 59.5 52.5 42.5 24 65 54.5 57.5 59.5 59.0 56.0 50.5 40.5 30 68 55.0 60.0 61.5 62.5 60.0 58.0 49.5 36 71 59.5 59.5 62.5 65.0 63.0 61.5 55.0 48 70 57.5 59.5 0.0 65.0 62.5 60.0 54.0 80 73 61.0 62.0 64.0 67.0 65.5 65.5 57.5 NOTES: Tested in accordance with AHRI Standard 270-08(not listed in AHRI). Accessory sound shield will not accommodate unit sizes 18 and 24. CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) UNIT SIZE-SERIES REQUIRED SUBCOOLING°F(C) 1B 12(6.7) 24 12(6.7) 30 12(6.7) 36 8(4.4) 46 12(6.7) W 10(5.6) 7 A2. ••� - — .1 'Tf- _ pp3ti Ra4,a see- € J_ ;Q �n io:om 43' 0l9 d m 2i w ` Uo �han4 G�Q,� oc ms e.•umo<eo momm o - �gm_ IO m ie000aro _ _ .+•n a �ww 0 4 � W oti : e 0o d moe`room W J_ a a xo M Vo 0 0 0 0 0 09•E•00 W L o00000 09•E•OEZ/BOZ a d 1 u o00000 09+0EZ W 2 �. .... 09.1-OEZ-80Z A s t! -- a!ED 13 a � x � Jo CL J ~~ Y f L o L - -I o�o TF- 1�_Y U Z 7 m Q n o W ccni 09.E-194 09-E-OEZ/90Z LL;� C/� w a "a".. 09i-OEZ 1 d L)' MI-OCZ-90Z a z � � w - A 9 TESTED AHRI COMBINATION RATINGS* NOTE: Ratings contained in this document are subject to change at any time. For AHRI ratings certificates,please refer to the AHRI directory www.ahriditvctor,'.org Additional ratings and system combinations can be accessed via the Bryant database at:w�.MyBtyantRatings com For performance data at specific application&/or design conditions with various indoor unit combinations,the equipment performance calculator can be accessed at: http://romonhry.wrightsoft.com/ Outdoor Model Number—Series(voltage) Indoor Coll Model Number Furnace Model Number Capacity EER SEER 124ANS016—A(N) CNPV*3014AL*+TDR 16,000 12.2 14 124ANS024—A(N) CNPV*3117AL*+TDR 24,000 12.2 14 124ANS030—A(N) CNPV*3117AL*+TDR 29,600 12.2 14 124ANS036—A(N,P,E) CNPV*3717AL*+TDR 35,400 12.2 14 124ANSO48—A(N,P,E) CNPV*6024AL*+TDR 45,000 11.7 14 _124ANS060—A(N,P,E) I CNPV*6124AL*+TDR 57,000 11,7 14 EER —Energy Efficiency Ratio SEER—Seasonal Energy Efficiency Ratio TXV —Thermostatic Expansion Valve NOTES: 1.Ratings are net values reflecting the effects of circulating fan motor heat.Supplemental electric heat is not included. 2.Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners.Ratings for other combinations are determined under DOE computer simulation procedures. 3.Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 4.Do not apply with capillary tube coils as performance and reliability are significantly affected. 10 w oog oommm mmmf8 inm STY 000 T O O O O O O O O O O O O O N N N N N N N N N N N N N N N N F M N N N N N N N N N N N N N N N vy m 08 N O O Q ttpp f m N 0fQr� oQ opNfoNfMV � NNa; � ) f � w N N V N fD V N m W 0 N N Ol N t7 R N N N O1 LQ N U fd a m of vi fo a fi a s fd a m v v V of is W fc of fd m w oI m fri fri N — N r N m #3 m m m m m N N N N N N m C Q 7 i3 p m m m m m m N N N n !p Fy 3 r r I, I, r m m m m m m m m m fo y Y N N N N N N N N N N N N N N N SC — — r — r — — — — — — — r L w m y n L o n in m o e a `�. cm & f� moof� c� $ u� � � i `3irn �'n , ngN °dm `f4 � r V V aj N N YI i2 O [2 fV ff) fN ' NI f(1 Q N of V N tC tC N N m r r N N pQu q w t7 Q R V f0 T n O O r N m N C W of m a N V fro N N f�J m n r V n N a a a r V A N fl� W Q fn N (� N N m m m N N m N N N N m N N (p (p W a Y In Q V Q m m m m m m N N N N m m m m m m m m m m m t0 f0 m m ��' N N N N N N N N N N N N N N N r �- V LL � mm (�pp ((pp pp m tp LL � pp pp�� aa (fpp Nf� mf� mm y L C m N b N N N fn m N W t0 N NC 0 0 Q fN N N fN m m N Q fo m o01. m (V Q t2 f] m N T N O m -6 16— w � � � p N f0 �[) N N f7 1� m N N V m n N N O pp f� pp (fpp pp m �p Y pp m p {p �y p m N N r O � m N O N � 8 A a' � O w m r N 2 m t0 O 8 N O m N 3i, o V m m �[) N m r N N N of r N tO LD U B N N N N N N N N N N N N N N N Q Q a Z m a i m fn N fn n n n o 0 0 0 0 2 Y T3 : v a v a a s u� in in �n u� ¢ a m N N N m r m m o 0 0 N . rnrnmrnrnrnrnfn �i, rn00000 H F H f y — N N N N N W Z ¢¢W pp {p (fpp ^f� pp W v L w N fo O of m n m f0 N O] m 7 C z y O N N R N O N N — T — Q N n A � � y m t0 YI of N a n r N N a m m N N }^Z V S — . pp p � � — — f op kS. . t ip � pp� m fro 0I � Ol m 8@ z � r N m m .N- 4 Y Omf fm0 Ol_ fmo_ N N O N V t7 m N fp O w w V F m I� m lf) N of m 0 10 16 fJ w w fA fA (� � M t7 fG 7 N F N N N N N N N N N N N N N N N m i v a m m m m m m m a a: of a a m m m m r r n m m - m m m m m m m �T - y F N� `a, oi 'n � T O (V N fN f0 NPl fGa a r A y m r (D 6 N a lU r m N N fA m V Q VI m 2 y tl N UW �■p...w N mN N ONaf N N — N N k Nmm pNa G 8NN r p 9 z NN v (m V � N N N N N N N N N N N N m m m m m n a a a 7 V m a: m n n n N {p fn fn fn fn .- N N N N N N N N N N N io fo N w m t0 f0 f0 f0 f0 t0 f0 f0 f0 �Uy7 V a a �j l'j (Ny m mm ^ pp N mm NN m p m m r m p� N N m N m t �y FL C W f7 r f0 m N (O S W t0 f0 C N N r m N m n O a N n m fA O m N m r r v m LD r N fN a m m le �T H a r m N N v m m N N N m m N N u ON m N WN Nai r fD V fi m a Ol m A U a v v O G N N Yf N N N N N N N N N N N N N N N WR a^N m N R N I�m N Q N T Q N v N�rn N Q N n m N a N Ol m Q V m r fC ....(V 'f ...m V -4 12 f� f0 o Q m IL .car ((�� ff�� � � WW3 (mayy .r...N..�((��� Nam_ 0 1°L n m N n N r m to I[ r fr0 fo fNo fro LL n fro fm0 fND frn n tr0 fmo fo Yr1 n fro to f0 N O mmmfnrmm ° O EI a P it m m O m N OmI N F y� H�.� of of of of of of of of �i of (o (o of ni L7 H M� t7 m m m m m of of of (o a ni of of of N m m `�' L7+ C O N N n m O m w N Co r V N N N Ol 00 A m N N � m m N N m N m N N N m m m Pl N N N — N N N A C m ((f m m y w N N N N 0 N N N N N N N N N Uq N m N N N m 7 N L7 Pi (6 Q N 6 6 (U w (O O m 6 (.: r m N m m O O m m mi O O O O O O O O O O g N m N (N N N H N H N L•i L•) w N LV L.) L•) L7 L7 0 L7 L L7 L7 to f y o l•] L7 to to Vi L7 to Ll VI N l) L7 to .- m t N C m 6 m m A A A m m m (O O (O v mnn o ai m � � m NN N N NN N o oo N A Nv 0N 0N moNf ncNn N mN NN nN N N ppNR N((1 N NV �■a m , . z AI m O 9 9 9 md c c v mN v NN mommmo 00666 moo o m m m m v m m W A V N N N m p('� m v N N N N O m m m m m v m m A m m f0 (O A .g Ali N N N N N N N N N N N N N N N (A tllto tlI m (7 (7 Ol m N (7 O] (7 (7 L7 N L7 U U m LL m � m � m o mi cmv o � � n � (� �i m y g m m � (�i lgi o A � `� 1(P(P1��yy LU N m m m N N N O N N m N N N N ? (A m N N N N N N N N N a a' mLU 4 'a, m $', (`Srnrn1O � oNNFi'irn a � m �i,, � `alg'ioaimmm � , `(Suoi. noi. mm U H 0 1A m N m O A ui N N m m N m U m N O O O (p (7 O N Co N N W m N N N N m N N N N m N N N N F H m m (7 m m (7 (7 (7 (7 (7 (7 (7 (7 t(77 m Q Q Q U O R 9 9 (�, m m m m v m m = 0 3 o m3 N ui g�, m m m m m m m m m m m rn rn m m F y F y N N N N N N N N N N N N N N N N N N f H N N N N [V N N N N N N N N (V N W W W pp ((�� pp�� R 1y7� p pp pp LU WO '�'' L WC • r r N N N m O V (�l Q N N g (7 Z C • r m N m m m m (NO N � O G 9 N � O m 0 m of m (7 m m O O n n A N CO CO m O m a m N N N N N N N N N N Z y N N N t'1 (7 N N N N N N N N (7 W U U qa& p p p p F U $ • OA1 O Omf N N (O V V t7 O m (7 m W • (� m 7 O m V m �2 (7 N m m N N N � r r N 6 I O n m m U � m 7 N N m N N m (N N N (7 l . O. . . (7 N N N N (7 N N N N () N N N N (7 P] N O (7 m N O O co co co m m (7 F E m m 7 N N m m m m v m m m a q« O m to m m m 7 N N N N O m N N m m r�i• .�. N T3 m m m N m m m (O m m (: N� (O (O (O H y( F y( N N N N N N N (V N N N N N N N y Y N N N N N N (V N N N N N N N N O � a of m o A m m +� A r m A (n i NmCOm A o � $ `d m mvgma`am n n � mn m ammaAnm � � mm m ro0of Co r� 0NmmN mof m NN (i NNra Hoof NN Wm m N N N N N N N N N N N m y N N N 0 0 N N N m N m N m m H3 (p (� A m Ol (O r f0 tO m N Lip LYE u] m N r (9 a m N 1� i[f m N m m q �O Lm{ N Ol 1� a m CO CO Q m m Oi U L+ m V Co Co A V V V I� N N 1f1 UU b5 m N N N (7 O N N N 0 7 N N N H 7 7 m m V o] m m m a m m m n mmrnmrnrnrnrnrn `ornSrnB s�' moimmma � mmm � — N T ITFI aa (�pp mm ((�� m cl A (p p p m v C•C m m W W n O m N (O N a n L N Q ? (O 1� V t7 N O A f0 N Ol V N N d m O m N m I� N m m m N N O O y( 0 N N N m N N m m N N N A fo A y w N � N N N N N N C4 N N 0 S A � y N N N L7 1 N N N Pl O N L7 N co co O TT O C3 N Ol m 6 m 0 � 6 6 6 7 m m r n 0 W N r N 6 4 N V (O N a m Oml r V t7 U c3 N Oi 0 m N N O N O N N 0 0 0 U N m N (i a N 01 O O {pp (7 Of A N Co Co m m M V m m co co V (n co m (7 V co v] (n L7 AQ N A m N a N f�m N Q N Ol ¢ N a N A W N C N f�m N Q N 1�W m mU oirN _V Voi r_ Noi .NN..oinNni G m3� of r (_d v_ vof n (d v_ Vof A (o (Li 6 0 in n d m m IS A ' 12 IN N mt�l m N myl 0 0 N ill N m 6 (p p p ppppv N8 8m a (o, N `cy fa0 (P NNNNOpIcalNC7mNNNmmmm cm NmOaly aNcm7mvvcnam.m& ppp pp .kgc� m p �p �O (� f� p�IN N a m n m a m r cr7 - f0 q a N O 2 O g s a v N N 1z � P� N N o m : m N m o o v r m m N m m m r m s v m m v v N m m m N N 8 rr (nrrmmr rr- mmmmm ��. ommmm oaaoN r H v a v v v v v a a a v v v a v fA (d ui 6 yi ui fd f6 (d (d (d (d f6 fd (d fd � _m N - r m r cy r m r N O r (� - N N pp�� p� cm� (� r r w C C a m N m m m m N m m Ol C r m & .- O v fp0 0 f0 N Ol N c7 m r O rn Nft) Nmo ui NcmnmmNmcmnmm y Nfr7mQVslamWilm � a � � s o ill {Sj o m c4 $ $ cO1v � nb' m amrnoi � m `f3 m l3oN m . .Fd Smn o O F vmmmfravvOr) mmv � mmm U N Nv a a w a a v v o a v m m U a N 8 pN� p �r�p 1� p� ) �p LL p y* ♦ 4 N N a V a v < a a a a s V T Y c7 m m fao im0 °V, a `� fm0, fm0 N N N m y M [ H(A W f0 o w w m N N yi yl N N N f6 6 'C O U ✓j °o pLL c pp�� N mm N 84 m 2 m m O ro t C � N A mW (pm A 7 �C O mm m N Zt � p pN m Q v av p N N A A (Opf pOf � cO 4 Q 2 N d q m q (� (y c� �p �p p .Wo a N cr�l cal 2 T O m fro m m V m � q • t0 fmn O ON) m (7 c�i n !n N n � N Ol Oi Y _m . w vmmmvag vavvaa U . WmifsvaNTNi[IwwwoN Q y m R m O Co cad Z Y i. m m m m m m al p01 m m 0 O1 pmf pmf z O 4 t7 r N N N v m N v c7 a m m N N V m �0s. m m m m m o m rn m m r o 0 o o a w H m of of ai m of m m of m a m of of w N1 a a a a a ui v v v v vi fd yi fd yi v m w 6 �y p p p �fOO p pp cc�� pp�� p (y ((pp pp�� fA C • a 8 8 m N O m .N- n � � N � O Of � � C • a f0 O 10 m � a fD N N r O O N r °v N 2. rn � � mvNm aaN ; m � a om m� gmv mcl) It mmmv < ymi ymicl U >� U •b c� c ■a pp mm ((�� p �O �O !O fy T?l, O cN fp m m N N (O 2 a m O N o 7Q Q U c1lw yr) N N N m N N N N fm0 N 1mY m ymy—N o G� Q �\ p �(pp �fpp mm mm mm m c� �pcmr� Q o T N v v V V tp o Lq fo fmp fm0 (m0 fm0 (m0 tmY m m m u v m v v N Q Q ? f0 m N m N p C of ii U Hy m m of m of m of m m of m of m of FU1 Yvvvv vvvv v vv o 0 O n0� m o y�O� p� pp p� c� �� m iY = N N �i m N m N 0 (a0 f0 c7 r Ol N LV L m yrI n r �Ny c� p� ��pp m N N fa7 N C p (� p C .- m N (7 m N fp m _... m � (� Nfa� mavNm m 44 9mfr� vv � � �, a � aNm � a � mma � NN go Aso o £ & — e 3 a oRvnoy3rm � S � w OFac� � `a a Nome `y3 `f89? fe `SfM536mi. A . � a - m UU na � (aau� vvaay`�ivvvv U m $ mmifayfmY (opymimmnro ouriymim .28 o Q �y cy p p p� Q� o y* m_ m_ N_ N_ ta7Nca� ryrymmcomt'1 T� o orn mm °' ao `, 8 N ry m NN t51 o L U F 53C t 1 of m of m of of of m m of m of f/l v v of of e a a a a v a a a m o c o c a V m g o £ p C Q ^ m a m rr �cp7 N t0 m n E. C tD m N m N pl fro r ma {ap cpp0 yppI A y N m m v V N c0 m 7 a m m m 2 ,, m a 7 N N m a v N m m V V 8 N �CO w O � � p u � IF o w Y fp tp cp fp pp y C f/1 a O U cd m m a v N O m (O fO f6 a r m r V m N m am m Ol c�c�� m m m m O a O O O N�N ttl U N N N N a Q a m m N N N m fD N N N r m m m m m U 9 n m g N�Of N v^N(�m N�N 01 g Q m E.. v v... ..`_......... ...v..J Q Ol ri f6 m N m r w m N m � m t7 m �O i~m m fll r fcyd Ol N OI c1r cG c7 N (T I� cd N m U LS v.N.i .r.J cry v N c� .r.. Q OLL r fr0 fm0 (O N r fr0 f0 tN0 N r fro fm0 fN0 yr1 IL r w co (NO N r (rY (mY c0 0 N tr0 @ cN0 if c���� �p, HO O c E w® 8Y7N m um LL n v mG A $ emlpmV� �� }{} M Z 13 CONDENSER ONLY RATINGS CONDENSER ENTERING AIR TEMPERATURES°F(-C) °FCC) 55(12.76) 1 65(18.33) 1 75(23 89) 1 66(29.44) 95(35.0) 105(40.56) 115(46.11) 125(51.87) 30 TOG 16.60 15.60 14.70 13.80 12.90 12.00 11.10 10.10 (_111) SDT 68.50 78.00 87.50 97.00 106.50 116.00 125.40 134.70 KW 0.76 0.87 0.99 1.11 1.25 1.40 1.59 1.80 35 TCG 18.30 17.20 16.30 15.30 14.30 13.30 12.30 11.20 (167) SDT 69.70 79.20 88.70 98.20 107.60 117.00 126.30 135.50 KW 0.76 0.87 0.99 1.11 1.25 1.41 1.59 1.80 40 TCG 20.00 19.00 17.90 16.90 15.80 14.70 13.60 12.40 (4.44) SDT 71.10 80.50 89.90 99.40 108.70 118.00 127.20 136.30 KW 0.77 0.88 0.99 1.11 1.25 1.41 1.59 1.80 45 TCG 22.00 20.80 19.70 18.50 17.40 16.20 14.90 13.00 (7,22) SDT 72.50 81.90 91.30 100.60 109.80 119.00 128.20 137.20 KW 0.77 0.88 0.99 1.12 1.26 1.41 1 1.59 1.80 60 TCG 24.00 22.80 21.60 20.40 19.10 17.80 16.40 15.00 (10.0) SDT 74.00 83.40 92.60 101.90 111.00 120.10 129.20 138.20 KW 0.77 0.68 0.99 1.12 1.26 1.41 1.59 1.80 55 TCG 26.30 25.00 23.60 22.30 20.90 19.50 18.00 16.40 (12.78) SDT 75.60 84.80 94.10 103.20 112.30 121.30 130.30 139.20 KW 0.78 0.88 1.00 1.12 1.26 1.42 1.60 1.80 , 30 TCG 21.40 20.20 19.00 17.80 16.60 15.40 14.20 12.90 (_111) SDT 71.90 81.30 90.70 100.00 109.30 118.50 127.70 136.80 KW 1.01 1.15 1.30 1.46 1.64 1.85 2.09 2.36 35 TCG 23.50 22.20 20.90 19.60 18.30 17.00 15.60 14.20 (167) SDT 73.50 62.80 92.10 101.30 110.50 119.60 126.70 137.70 KW 1.02 1.16 1.30 1.47 1.65 1.86 2.09 2.37 40 TCG 25.70 24.40 23.00 21.60 20.20 18.70 17.20 15.60 (4.44) SDT 75.10 84.30 93.50 102.60 111.80 120.60 129.80 138.80 KW i.02 1.i 6 1.31 1.47 1 1.66 1.66 2.10 2.38 45 TCG 28.20 26.70 25.20 23.70 22.10 20.50 18.90 17.10 (7.22) SDT 76.70 85.90 95.00 104.10 113.10 122.10 131.00 139.80 KW 1.03 1.17 1.32 1.48 1.66 1.87 2.11 2.39 50 TCG 30.80 29.20 27.50 25.90 24.20 22.40 20.60 18.70 (10.0) SDT 78.50 87.50 96.60 105.60 114.60 123.40 132.20 140.90 KW 1.04 1.18 1.32 1.49 1.67 1.88 2.12 2.39 55 TCG 33.60 31.80 30.10 28.30 26.40 24.50 %40 20.30 (12.78) SDT 80.30 89.30 98.30 107.20 116.10 124.90 133.50 142.00 KW 1.05 1.18 1.33 1.50 1.68 1.89 2.13 2.40 30 TCG 1 27.20 1 25.80 24.40 22.90 21.40 19.70 17.90 16.00 SDT 69.90 79.20 88.60 98.00 107.30 116.60 125.80 134.80 KW 1.22 1.39 1.57 1.77 2.00 2.27 2.58 2.94 35 TCG 30.10 28.50 27.00 25.40 23.70 21.90 20.00 17.90 (167) SDT 71.20 80.60 89.90 99.20 108.50 117.70 126.80 135.80 KW 1.22 1.40 1.58 1.78 2.01 2.28 2.58 2.94 40 TCG 33.10 31.40 29.70 28.00 26.20 24.30 22.20 20.00 (4.44) SDT 72.70 82.00 91.20 100.50 109.70 118.90 127.90 136.90 KW 1.23 1.41 1.59 1.80 2.03 2.29 2.59 2.94 45 TCG 36.50 34.50 32.70 30.80 20.80 26.80 24.50 22.10 (7.22) SDT 74.30 83.50 92.70 101.90 111.00 120.10 129.10 137.90 KW 1.25 1.43 1.61 1.82 2.05 2.31 2.60 2.95 50 TCG 40.00 37.90 35.80 33.80 31.60 29.40 27.00 24.40 (10.0) SDT 76.00 85.10 94.20 103.40 112.40 121.40 130.30 139.00 KW 1.27 1.45 1.64 1.84 2.07 2.33 2.62 2.95 TCG 43.80 41.40 3920 36.90 34.60 32.10 29.50 26.70 55 SDT 77.90 86.90 95.90 104.90 113.90 122.80 131.50 140.20 (12.78) KW 1.29 1.47 1.66 1.87 2.09 2.35 2.64 2.97 See notes on page 15 14 CONDENSER ONLY RATINGS CONTINUED SST CONDENSER ENTERING AIR TEMPERATURES°F(°C) °F(°C) 55(12.78) 85(18.33) 75 23.89 85(29.44) 95 35.0 106(40.58) 115 45.11 125(51.67) 30 TCG 31.40 29.80 28.20 26.40 24.60 22.70 20.60 18.50 (_111) SDT 68.70 78.10 87.50 96.80 106.20 115.50 124.70 134.00 KW 1.48 1.69 1.91 2.14 2.40 2.69 3.04 3.44 35 TCG 34.70 32.90 31.10 29.20 27.20 25.10 22.80 20.50 (167) SDT 70.00 79.30 88.60 97.90 1 107.20 116.40 125.60 134.80 KW 1.48 1.70 1.91 2.15 2.41 2.70 3.05 3.45 40 TCG 38.20 36.20 34.20 32.10 29.90 27.60 25.20 22.60 (4.44) SDT 71.30 80.50 89.80 99.10 108.30 117.40 126.50 135.60 KW 1.49 1.70 1.92 2.16 2.42 2.72 3.06 3.45 45 TCG 42.00 39.80 37.60 35.30 32.90 30.30 27.70 24.60 (7.22) SDT 72.80 81.90 91.10 100.30 109.40 118.50 127.50 136.40 KW 1.50 1.72 1.94 2.18 2.44 2.73 3.07 3.46 50 TCG 46.00 43.60 41.10 38.60 1 36.00 33.20 30.20 27.20 (10.0) SDT 74.40 83.40 1 92.50 101.60 1 110.60 119.60 128.50 137.30 KW 1.52 1.74 1.96 2.20 2.46 2.75 3.08 3.47 55 TCG 50.20 47.60 44.90 42.10 39.20 36.20 32.90 29.60 (12.78) SDT 76.10 85.00 94.00 103.00 111.90 120.80 129.50 138.20 KW 1 1.54 1.76 1.98 2.22 2.48 1 2.77 1 3.10 3.48 30 TCG 41.50 39.50 37.40 35.40 33.20 30.80 28.20 25.40 SDT 73.40 82.60 91.90 101.20 110.40 119.50 128.60 137.50 KW 2.05 2.30 2.57 2.87 3.21 3.60 4.05 4.56 35 TCG 45.70 43.40 41.20 38.90 36.50 33.90 31.10 28.10 (167) SDT 75.10 84.30 93.40 102.60 111.70 120.80 129.70 138.60 KW 2.08 2.33 2.60 2.90 3.24 3.63 4.08 4.60 40 TCG 50.10 47.70 45.20 42.70 40.10 37.20 34.20 30.90 (4.44) SDT 77.00 86.00 95.10 104.10 113.20 122.10 131.00 139.70 KW 2.12 2.36 2.63 2.93 3.27 3.67 4.12 4.64 45 TCG 54.80 52.20 49.50 46.70 43.80 40.70 37.40 33.80 (7.22) SDT 78.90 87.80 96.80 105.80 114.70 123.50 132.20 140.80 KW 2.15 2.39 2.66 2.96 3.31 3.71 4.16 4.69 10 TCG 59.90 56.90 1 54.00 51.00 47.80 44.40 40.70 36.80 (10.0) SDT 80.90 89.80 98.60 107.50 116.30 125.00 133.60 1 142.00 KW 2.19 2.43 2.70 3.00 3.34 3.74 4.20 4.72 68 TCG 65.20 62.00 58.80 55.40 51.90 48.20 44.20 39.90 (12.78) SDT 83.10 91.80 100.50 109.30 117.90 126.50 134.90 143.20 KW 2.24 2.47 2.73 3.03 3.38 3.78 4.24 4.76 0.0 30 TCG 53.00 50.30 47.70 45.10 42.40 39.40 36.00 32.40 SDT 76.00 85.10 94.30 103.50 112.70 121.70 130.60 139.40 KW 2.59 2.90 3.23 3.61 4.03 4.52 5.08 5.71 35 TCG 58.30 55.30 52.50 49.70 46.60 43.30 39.70 35.70 (167) SDT 78.00 87.00 96.10 105.20 114.20 123.10 131.90 140.60 KW 2.64 2.94 3.28 3.65 4.08 4.58 5.14 5.78 40 TCG 63.90 60.70 57.60 54.50 51.10 47.50 43.60 39.30 (4.44) SDT 80.00 88.90 97.90 106.90 115.80 124.70 133.30 141.90 KW 2.69 2.99 3.32 3.70 4.14 4.63 5.20 5.84 45 TCG 70.00 66.50 63.10 59.60 55.90 51.90 47.60 42.90 (7.22) SDT 82.20 91.00 99.90 108.80 117.60 126.30 134.80 143.20 KW 2.74 3.04 3.38 3.76 4.19 4.69 5.27 5.91 50 TCG 76.40 72.60 68.80 65.00 60.90 1 56.50 51.80 46.70 (10.0) SDT 84.60 93.30 102.00 110.70 119.40 127.90 136.30 144.50 KW 2.80 3.10 3.43 3.81 4.25 4.76 5.33 5.97 TCG 83.30 79.10 74.90 70.60 66.10 61.30 56.10 50.60 55 SDT 87.00 95.60 104.20 112.80 121.20 129.60 137.80 145.80 (12.78) KW 2.86 3.15 3.49 3.87 4.31 4.82 5.39 6.04 "AHRI listing applies only to systems shown in Combination Ratings table. KW - Outdoor Unit Kilowatts Only. SDT - Saturated Temperature Leaving Compressor(°F) SST - Saturated Temperature Entering Compressor(°F/°C) TCG - Gross Cooling Capacity(1000 Btuh) 15 GUIDE SPECIFICATIONS AIR-COOLED,SPLIT-SYSTEM AIR CONDITIONER 124ANS GENERAL 1-1/2 TO 5 NOMINAL TONS System Description — Condenser fan motors will be totally enclosed,1-phase Outdoor-mounted,air-cooled, split-system air conditioning unit type with class B insulation and permanently lubricated suitable for ground or rooftop installation. Unit consists of a bearings.Shafts will be corrosion resistant. scroll-type hermetic compressor, an air-cooled coil, — Fan blades will be statically and dynamically balanced. propeller-type condenser fan, and a control box. Unit will — Condenser fan openings will be equipped with coated discharge supply air horizontally as shown on contract drawings. steel wire safety guards. Unit will be used in a refrigeration circuit to match up to a Compressor packaged fan coil or furnace. Quality Assurance — Compressor will be a scroll-type,hermetically sealed. Compressor will be mounted on rubber vibration — Unit will be rated in accordance with the latest edition isolators. of AHRI Standard 210. — Unit will be certified for capacity and efficiency, and Condenser Coil listed in the latest AHRI directory. — Condenser coil will be air cooled. — Unit construction will comply with latest edition of — Coil will be constructed of aluminum fins mechanically ANSI/ASHRAE and with NEC. bonded to copper tubes which are then cleaned, — Unit will be constructed in accordance with UL dehydrated,and sealed. standards and will carry the UL label of approval.Unit Refrigeration Cmnonents will have c-UL approval. — Refrigeration circuit components will include — Unit cabinet will be capable of withstanding Federal liquid-line front-seating shutoff valve with sweat Test connections, vapor-line front-seating shutoff valve Method Standard No. 141 (Method 6061)500-hr salt with sweat connections, system charge of Puron® spray test. (R-410A)refrigerant,and compressor oil. — Air-cooled condenser coils will be leak tested and — Unit will be equipped with high-pressure switch, low pressure tested pressure switch and filter drier for Puron refrigerant. — Unit constructed in IS09001 approved facility. Operating Characteristics Delivery,Storage,and Handling — The capacity of the unit will meet or exceed Btuh at a suction temperature of °F/°C. The Unit will be shipped as single package only and is power consumption at full load will not exceed stored and handled per unit manufacturer's kW recommendations. Combination of the unit and the evaporator or fan coil Warranty(for inclusion by specifying engineer) unit will have a total net cooling capacity of — U.S.and Canada only. Btuh or greater at conditions of CFM entering PRODUCTS air temperature at the evaporator at °F/°C wet bulb and °F/°C dry bulb, and air entering the Equipment unit at °F/°C. — Factory assembled, single piece, air-cooled air — The system will have a SEER of Btuh/watt or conditioning unit. Contained within the unit enclosure greater at DOE conditions. is all factory wiring, piping, controls, compressor, refrigerant charge Puron® (R-410A), and special Electrical Requirements features required prior to field start-up. — Nominal unit electrical characteristics will be v, Unit Cabinet single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of v — Unit cabinet will be constructed of galvanized steel and to V. bonderized. — Nominal unit electrical characteristics will be v, Fans three phase, 60 hz. The unit will be capable of — Condenser fan will be direct-drive propeller type, satisfactory operation within voltage limits of v discharging air horizontally. to V. — Unit electrical power will be single point connection. — Control circuit will be 24v. Special Features Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. 16 Copyright 2015 Bryant Heating&Cooling Systems•7310 W.Morris St.• Indianapolis,IN 45231 Edition Date:01/15 Catalog No:PDS124ANS-01 Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. Replaces:New 17 �_ ., I� Permit#: 1562 Permit Date: 07/21/17 Permit Type: RESIDENTIAL MECHANICAL Project Name: Swanson Applicant Name: Black Lion HVAC Applicant Address: 11001 118th Place NE Applicant, City, State, Zip: Kirkland, WA 98033 Contact: Brenda Lopez Phone: 425-814-3944 Email: brenda@blacklionhvac.com; info@blacklionhvac.com Scope of Work: Install A/C Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 07/21/2017 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 142 Single Family 01119852600200 526 FRENCH AVE UNIT B SWANSON KARLA Residence J Condominium Common Wal Contractors Contractor Primary Contact Phone Address Contractor Type License License# BLACK LION HVAC BLACK LION 425-814-3944 11001 118TH PL CONSTRUCTION LABOR&BLACKLH873QQ HVAC NE CONTRACTOR INDUSTRIES Plan Reviews Date Review Type Description Assigned To Review Status 07/21/2017 RESIDENTIAL z.Rick Karns MECHANICAL Fees Fee Description Notes Amount Air Cond.Unit Btu/h<100>; $25.00 Btu/hp>500 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Total $75.00 Attached Letters Date Letter Description 07/21/2017 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 07/21/2017 Lynai Clark 65619394 cc $75.00 Outstanding Balance $0.00 Notes Date Note Created By: 07/21/2017 Out of City has expired.KF Kristin Foster 07/21/2017 Emailed permit for signature and inspection card.KF Kristin Foster Uploaded Files Date File Name 07/21/2017 2466798-1562 Issued Permit.pdf 07/21/2017 2466310-1562 BRYANT 124 SPECS.pdf 07/21/2017 2465870-1562 Application.pdf