Loading...
HomeMy WebLinkAbout427 N Olynmpic Ave_BLD1558_2026 �•�Y o� COMMERCIAL MECHANICAL • PERMIT APPLICATION �Lj� rt Department of Community& Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF CONSTRUCTION DRAWINGS AND ALL OTHER INFORMATION OUTLINED IN THE MECHANICAL PERMIT SUBMITTAL REQUIREMENTS, IF APPLICABLE. Type of Permit: n New Installation Replacement ZI Alteration Project Address: 4ft N OLYMPIC AVENUE Parcel#: STALL DUCTLESS HEAT PUMP Project Description: T Valuation:5350.00 Owner:NORMA KNUDSON Phone#:425-750-8886 Address: OLYMPIC AVENUE City:ARLINGTON State:WA Zip:98223 . Email Address: KNUDSON2014@OUTLOOK.COM _ Dtbbill- Contact Person: Phone#: 425-259-0550 Address: 1415 BROADWAY City:EVERETT State: WA Zip: 98201 Email Address:DEBBIE@CMHEATING.COM Contractor Name:C.M. HEATING INC _ Phone#: 425-259-0550 1415 BROADWAY EVERETT WA 98201 Contractor Address: _ City: State: Zip: Email:DEBBIE@CMHEAIING.COM Contact Person: DEBBIE Contractor License Number: CMHEAI*095R4 _ Expiration: 05/19 Please indicate type of number of appliances: FURNACE CONDENSING UNIT GAS PIPING OUTLET BOILER HEAT PUMP(multi-split) UNIT HEATER CHILLER HEAT PUMP(mini-split) I PAINT BOOTH COOLER HEAT PUMP(other) TYPE I HOOD AC(air cooled) HEAT REJECTION EQUIP TYPE II HOOD AC(water cooled) VENTILATION SYSTEM AST AC(evaporator) PACKAGED UNIT UST AC(VRF) DRYER OTHER I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in acc' '•y.;`•?`te laws rules and regulation of the State of Washington. Z)W-o,ta/0 tau!'.cZ Applicants Signature: Date 07/18/2017 Applicants Printed Name: Deborah Bauers FOR STAFF USE ONLY JUL. 18 2017 Permit# Accepted By Amount Received Receipt# Date Received 6/16LP Page 1 of 1 CITY OF ARLINGTON INSPECTION CARD No building construction shall be commenced until permit holder INSPECTION RECORD SHALL or his agent has posted this Inspection Record Card in a REMAIN AT JOB SITE conspicuous place on the premises. OWNER: Podner Properties, LLC CONTRACTOR: CM Heating Inc. JOB ADDRESS: 427 N Olympic Ave LOT NUMBER TYPE GROUP NATURE of WORK: Mechanical USE of BUILDING: Office PERMIT No: 1558 DATE ISSUED: 8.10.2017 INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB DEPARTMENT INSPECTION DATE(S) PASS FAIL INITIALS FOOTING BUILDING FOUNDATION (360)403-3417 UNDERFLOOR SHEARWALL PLUMBING(groundwork) ROUGH PLUMBING GAS PIPING ROUGH HEATING&VENTILATION FRAMING INSULATION WALLBOARD(SHEAR/RATED WALLS) CEILING GRID STRUCTURALSLAB CROSS CONNECTION CONTROL IN PREMISE PUBLIC WORKS GRADING (360)403-3457 TEMPORARY TECSP ASBUILTS APPROVED MAINTENANCE BOND STORM DRAINAGE SYSTEM PAVING,SIGNAGE&MARKINGS LANDSCAPING PLANNING CONDITIONS ONSITE UTILITIES WATER ONSITE UTILITIES SEWER Sewer OFFSITE UTILITIES WATER (360)403-3508 OFFSITE UTILITIES SEWER SEWER PRETREATMENT Water CROSS CONNECTION CONTROL PREMISE (360)403-3526 SIDE SEWER/CLEANOUT/FINAL WATER SERVICE INSTALLATION WATER SERVICE FINAL FIRE DEPARTMENT (360)403-3526 HYDRO/FLUSH (360)403-3607 UNDERGROUND""INCL FDC (360)403-3607 FIRE ALARM /AUTOMATIC SPRINKLER (360)403-3417 HOOD SUPPRESSION SYSTEM (360)403-3607 FINAL FIRE WALK-THROUGH (360)403-3417 FINAL INSPECTION ALL SIGNATURE BLOCKS MUST BE COMPLETE ' CITY OF ARLINGTON 238 N.OLYMPIC AVE-ARLINGTON, WA.98223 PHONE;(360)403-3551 BUILDING PERMT Address:427 N Olympic Ave Permit#:1559 Parcel#:00529900701701 Valuation;5350.00 OWNER APPLICANT CONTRACTOR Name:PODNER PROPERTIES LLC Name:CM Heating,Inc. Name:CM Heating Inc Address:427 N OLYMPIC AVENUE Address:1415 Broadway Address:1415 Broadway City,State Zip:ARLINGTON,WA 98223-1244 City,State Zip:Everett,WA 99201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Name; Address:1415 Broadway Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-259-0550 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Mechanical CODE YEAR: 2015 STORIES: 1 CONST.TYPE: DWELLING UNITS: 0 OCC GROUP: BUILDINGS: 1 OCC LOAD: PEMT APPROVAL 1 AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMENS COMPENSATION INSURANCE AND RCW 1827. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/1RC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in t ity of r t t n must be reported on your sales tax return form and ed City of Arlin ton#3101. Signature Print Name Date Released By Date CONDITIONS Approved as submitted.Additional requirements:seismic bracing is required,provide electrical disconnect, lines shall be insulated-the use of adhesive tape is not permitted. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC_)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 8/11/2017 Heal Pump $25.00 8/11/2017 Mechanical Permit Base Fee $25.00 8/11/2017 Mechanical Plan Review Fee $200.00 8/11/2017 ProcessinWTechnology Fee $25.00 Total Due: S275.00 Total Payment: $275.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: CITY OF ARLINGTON �\ 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 ` PHONE; (360)403 3551 BUILDING PERMIT Address:427 N Olympic Ave Permit#:1558 Parcel#:00529900701701 Valuation:5350.00 OWNER APPLICANT CONTRACTOR Name:PODNER PROPERTIES LLC Name:CM Heating,Inc. Name:CM Heating Inc Address:427 N OLYMPIC AVENUE Address:1415 Broadway Address: 1415 Broadway City,State Zip:ARLINGTON,WA 98223-1244 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Name: Address: 1415 Broadway Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-259-0550 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Mechanical CODE YEAR: 2015 STORIES: I CONST.TYPE: DWELLING UNITS: 0 OCC GROUP: BUILDINGS: I OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in ity.0 r t n must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Released By Date CONDITIONS Approved as submitted.Additional requirements: seismic bracing is required,provide electrical disconnect, lines shall be insulated-the use of adhesive tape is not permitted. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 8/11/2017 Heat Pump $25.00 8/11/2017 Mechanical Permit Base Fee $25.00 8/11/2017 Mechanical Plan Review Fee $200 00 8/11/2017 Processing/Technology Fee $25.00 Total Due: $275.00 Total Payment: $275.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Q ASS O 4` A S J tl\ 4` • 2 PS ) 12- r."'DAIKIN XIZ,N MVJ PrneAi S�e�e (1,]J Daikin City Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws. CAD CART(0) By Keyword All Categories>Single Zone Systems>Single Zone Heat Pump Outdoor Units>Single Zone Heat Pump Outdoor Units-RX Series>Model Number RX12NMVJU MODEL NUMBER RXI2NMVJU, 1.0-TON WALL MOUNTED UNIT Request Information Add to CAD Cart Printable Paae Download PDF Email This Pane DOWNLOADS Revit Family Download CAD DRAWING 3D Speafications Dimensions Features Benefits Frequency 60 Hz Voltage 208-230 V C_ 2D Front View Current 4.14-3.74/4.99-4.50 A Cooling Capacity 10900 Btu/h 1 31.3/26.1 m3/min U Airflow Rate(H) 1105/922 ft3/min 2D Left Side View Maximum Air Flow-Cooling 1105 ft3/min n Maximum Air Flow-Heating 922 ft3/min I I h Minimum Air Flow-Cooling 865 ft3/min 2D Right Side View Minimum Air Flow-Heating 777 ft3/min Compressor Type Hermetically Sealed Swing Type - 2D Too View Compressor Model lYC23AUXD Compressor Motor Output 790 W l�Refrigerant Oil Type FVC50K 2D Bottom View Refrigerant Type R-410A Refrigerant Charge 2.09 lb 0.95 kg Fan Type Propeller 2D Back View i C(lMµV3 ui r Gs �q 212 Fan Motor Output 18 W Power Consumption(Rated) 843-843/1013-1013 W I �i Power Factor 97.9-98,0/97.6-97.9% Revit Model Sound Pressure Level(H)-Cooling 49 dBA Sound Pressure Level(H)-Heating 49 dBA Drawing No. C:3D093559A Sensible Capacity 9480 Btu/h Heating Capacity 13500 Btu/h Cooling Input Power 0.874 kW Heating Input Power 1.041 kW Max/Min Cooling Capacity 13300/4400 Btu/h Max/Min Heating Capacity 16400/4400 Btu/h Ambient(°F DB/WB):95/75 Rated Cooling Conditions Indoor ff DB/WB):80/67 Rated Heating Conditions Ambient ff DB/WB):47/43 Indoor(°F DB/WB):70/60 Power Supply 208-230 V/60 Hz/1 Phase Heat Insulation Both Liquid and Gas Pipes Moisture Removal 0.45 gal/h Starting Current 5.24 A 60 Ib Weight 27 kg 71 lb Gross Weight 32 kg Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws. ■ ® This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2016. Certificate of Product Ratings AHRI Certified Reference Number: 8064266 Date: 7/18/2017 Product: Variable Speed Mini-Split Heat Pump,with Remote Outdoor Unit Air-Source, Free Delivery Outdoor Unit Model Number: RX12NMVJU r Indoor Unit Model Number: FTX12NMVJU Manufacturer: DAIKIN AC (AMERICAS), INC. Trade/Brand name: DAIKIN Series name: Manufacturer responsible for the rating of this system combination is DAIKIN AC (AMERICAS), INC. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source to Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third " party testing: Cooling Capacity (Btuh): 10900 EER Rating (Cooling): 12.50 �J SEER Rating (Cooling): 19.00 I• Heating Capacity(Btuh) @ 47 F: 13500 Region IV HSPF Rating (Heating): 9.00 Heating Capacity(Btuh) @ 17 F: 8100 I I r CERTIFIED RATINGS FOR VARIABLE-SPEED,MINI-AND MULTI-SPLIT SYSTEMS ARE VALID FOR ALL COMBINATIONS OF INDOOR UNITS (BASED ON COMBINATION TYPES)WITH THE SPECIFIC OUTDOOR UNIT LISTED ABOVE AND IN THE AHRI DIRECTORY OF CERTIFIED EQUIPMENT.VISIT WWW.AHRIDIRECTORY.ORG TO VERIFY THAT THIS COMBINATION IS AN ACTIVE LISTING AND THE DATA LISTED ON �I THIS CERTIFICATE IS ACC�IRATE. SEARCH ON THE AHRI F EF[RENCE#TO QUICKLY LOCATE THIS COMBINATION IN THE DIRECTORY. i Ratings fo lowed by an asterisk()mdica.to a voluntary rerate of previously r Iiic i, I !ata,unless accompanied with a WAS,whit in icates an involuntary ie;'Ai- DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS �� This Certificate and Its contents are proprietary products of AHRI.This Certificate shall only be used for Individual,personal and , confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; : -� entered Into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's Individual, personal and confidential reference. AIR-CONDmONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The Information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we make life better" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which Is listed above,and the Certificate No.,which is listed at bottom right. ©2014 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: f 31448693184161900 1 w6cc emphan6e ko' rm., Minimum Efflclem; Equipment Size Category Heating Section Sub-Category or Rating Test Type Type Condition Before After procedure 11112017 11112017 VRF <135,000 Btu/h VRF Multi-split System AIIRI 1230 Groundwater (cooling capacity) --- 50T entering water 3.6 COP source (heating mode) ?135,000 Btulh VRF Multi-split System (coolung capacity) --- 50T entering water 3.3 COP VRF <135,000 Btu/h VRF Mulli-split System AHRI 1230 Ground source (cooling capacity) ... 32°F entering water 3.1 COP (healing mode) >135,000 Btu/h VRF Multi-split System (cooling capacity) L --- 320F entering water 2.8 COP TABLE C403.2.3(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS EQUIPMENT TYPE SIZE CATEGORY HEATING SECTION SUBCATEGORY OR MINIMUM TEST a TYPE RATING CONDITION EFFICIENCY PROCEDURE Air cooled Split System 14.0 SEER <65,000 Btu/hb All (cooling mode) Single Packaged 14.0 SEER Through-the-wall, Split System 12.0 SEER AHRI g <30 000 Btu/fib 210/240 air cooled(codling mode) — Single Packaged 12.0 SEER Small duct high velocity,air cooled <65,000 Btu/hb All Split System 11.0 SEER Electric Resistance Split System and 11.0 EER >65,000 B(u/h and (or None) Single Package 12.2 IEER <135,000 Btu/h Split System and 10.8 EER All other Single Package 12.0 IEER Electric Resistance Split System and 10.6 EER > 1d<24 000 or None Single Package 11.6 IEER Air cooled ( ) g g AHRI and<240,000 (cooling mode) Btu/11 Split System and 10.4 EER 340/360 All other Single Package 11.41EER Electric Resistance Split System and 9.5 EER >240,000 Btu/h (or None) Single Package 10.61EER All other Split System and 9.3 EER Single Package 10.41EER <17,000 Btu/h All 86°F entering water 12.2 EER >_17 000 BtU/11 and Water source <�65,000 Btu/h All 86°F entering water 13.0 EER (cooling mode) >_65,000 Btu/h and All 86°F entering water 13.0 EER < 135,000 Btu/lr ISO 13256-1 Ground water source <135,000 Btu/h All 59°F entering water 18.0 EER (cooling mode) Ground source' <135,000 Btu/h . All 77°F entering water 14.1 F,ER (cooling mode) Water=source water to water <135,000 Btu/h All 86°F entering water 10.6 EER (cooling mode) 59°F entering water 16.3 EER Ground water source ISO 13256-2 Brine to water <135,000 BIu/h All 77°F entering fluid 12.1 EER (cooling[node) (cattlhrued) 2015 Washington Slate Energy Code CE-39 CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON,WA.98223 PHONE; (360)403-3551 BUILDING PERNIIT Address:427 N Olympic Ave Permit ll:1339 Parcel 0:00529900701701 Valuation:5350.00 OWNER APPLICANT CONTRACTOR ?game:PODNER PROPERTIES 1.1 C Name:CM Heating,Inc. Name:CM Heating Inc Address:427 N OLYMPIC AVENUE Address:1415 Broadway Address:1415 Broadway City,State Zip:ARLINGTON,WA 98223-1244 City,State Zip:Everett,WA 99201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Name: Address:1415 Broadway Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-259-0550 Phone: LIC N: EXP: LIC M EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Mechanical CODE YEAR: 2015 STORIES: 1 CONST.TYPE: DWELLING UNITS: 0 OCC GROUP: BUILDINGS: ] OCC LOAD: PERMT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMENS COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI10ARC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in th 'ity o r t n must be reported on your sales tax return form and co ed City of Arlin ton t13101. 1 .1-7 Signature Print Name Date Released By Date CONDITIONS Approved as submitted.Additional requirements:seismic bracing is required,provide electrical disconnect, lines shall be insulated-the use of adhesive tape is not permitted. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION, PERMIT FEES Date Description Fee Amount 8/11/2017 Heat Pump $25.00 8/11/2017 Mechanical Permit Base Fee $25.00 8/112017 Mechanical Plan Review Fee $200.00 8/112017 Processing/rechnology Fee $25.00 Total Due: $275.00 Total Payment: $275.00 Balance Due: E0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an iospectioo please leave the following information: / CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:427 N Olympic Ave Permit#:1558 Parcel#:00529900701701 Valuation:5350,00 OWNER APPLICANT CONTRACTOR Name:PODNER PROPERTIES LLC Name:CM Heating,Inc. Name:CM Heating Inc Address:427 N OLYMPIC AVENUE Address:1415 Broadway Address: 1415 Broadway City,State Zip:ARLINGTON,WA 98223-1244 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Name: Address: 1415 Broadway Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-259-0550 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Mechanical CODE YEAR: 2015 STORIES: I CONST.TYPE: DWELLING UNITS: 0 OCC GROUP: BUILDINGS: I OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRC 110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in th=On ported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Released By Date CONDITIONS Approved as submitted. Additional requirements: seismic bracing is required,provide electrical disconnect, lines shall be insulated-the use of adhesive tape is not permitted. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 8/11/2017 Heat Pump $25.00 8/11/2017 Mechanical Permit Base Fee $25.00 8/11/2017 Mechanical Plan Review Fee $200.00 8/11/2017 Processing/Technology Fee $25.00 Total Due: $275.00 Total Payment: $275,00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon • Permit Information Date 7/18/2017 Permit Number 1558 Project Name Knudson Applicant Name CM Heating, Inc. Applicant Address 1415 Broadway City, State,Zip Everett,WA 98201 Contact Deborah Bauers Phone 425-259-0550 Email debbie@cmheating.com Permit Type Commercial Mechanical Site Address 1427 N Olympic Ave Valuation 5350.00 Status Ready to Issue Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 1 Proposed Use Install Ductless Heat Pump Assigned To Kristin Foster Property Information Owner Information Parcel#:00529900701701 PODNER PROPERTIES LLC PODNER PROPERTIES LLC 427 N OLYMPIC AVENUE 427 N OLYMPIC AVENUE ARLINGTON,WA 98223-1244 Contractors Contractor Primary Phone Email Contractor Type License License# Name Contact (Meredith 425-259- MECHANICAL Labor& CM Heating Inc Silbert 0550 meredith@cmheating.com CONTRACTOR Industries �MHEAMH877DN Review Date Type Description I Target Date Completed Date I Assigned To Status 7/18/2017 lCommercial Mechanical 7/25/2017 JRick Karns JIn Review Fees Fee Descri tion Notes Amount Heat Pum 322.10.00.001 1 $25.00 Mechanical Permit Base Feel 322.10.00.01 $25.0 Mechanical Plan Review Fe 32Z 10,00.01 $200.0 ProcessingfTechnology Fe 341 A3.00,021 $25.0 Total $275.0 Notes Date Note 8/8/2017 No screening is required for the unit as it is located next to another existing unit Uploaded Files Upload File Date File Uploaded B 7/18l2017 4:20:05 PM 1558 Applicatjon.pddf IFoster, Kristin X 818/201/4:20:05 PM *1558 Specs&Plans.pdf IFoster,Kristin )( COMMERCIAL MECHANICAL • PERMIT APPLICATION •y r Department of Community& Economic Development City of Arlington• 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF CONSTRUCTION DRAWINGS AND ALL OTHER INFORMATION OUTLINED IN THE MECHANICAL PERMIT SUBMITTAL REQUIREMENTS, IF APPLICABLE. Type of Permit: F_� New Installation ❑ Replacement ❑ Alteration Project Address: WIN OLYMPIC AVENUE Parcel#: INSTALL DUCTLESS HEAT PUMP Project Description: Valuation:5350.00 Owner:NORMA KNUDSON Phone#:425-750-8886 Address: MOLYMPIC AVENUE City: State: Zip:ARLINGTON WA 98223 Email Address: KNUDSON2014@OUTLOOK.COM DEBBIE Contact Person: Phone#: 425-259-0550 Address:1415 BROADWAY City.EVERETT State: WA Zip: 98201 Email Address:DEBBIE@CMHEATING.COM Contractor Name.C.M. HEATING INC Phone#: 425-259-0550 Contractor Address: 1415 BROADWAY EVERETT WA 98201 City: _State: Zip: Email:DEBBIE@CMHEA-nNG.COM Contact Person:DEBBIE Contractor License Number: CMHEAI*095R4 Expiration: 05/19 Please indicate type of number of appliances: FURNACE CONDENSING UNIT GAS PIPING OUTLET BOILER HEAT PUMP(multi-split) UNIT HEATER CHILLER HEAT PUMP(mini-split) L_ PAINT BOOTH COOLER HEAT PUMP(other) TYPE I HOOD AC(air cooled) HEAT REJECTION EQUIP TYPE II HOOD AC(water cooled) VENTILATION SYSTEM AST AC(evaporator) PACKAGED UNIT UST AC(VRF) DRYER OTHER I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in taws rules and regulation of the State of Washington. Applicants Signature: Date 07/18/2017 Applicants Printed Name: Deborah Bauers FOR STAFF USE ONLY Ism JUL 18 2017 Permit# pted 89 Amount Received Receipt# Date Received 6116LP Page 1 of 1 :��.a� t '��'t � _ 1 7/18/2017 C M HEATING INC m;r spuFol FS. L&I A-r Bider Ihd1) M�l I&r Safety& Health Claims& Insurance V/carkplace Rights i Fades&Licensing A^ Washington State Department of " Labor & Industries C M HEATING INC Owner or tradesperson 1415 BROADWAY EVERETT,WA 98201 Principals 425-259-0550 GARNER,JAMES NICHOLAS,PRESIDENT SNOHOMISH County GARNER,JAMES NICHOLAS,VICE PRESIDENT GARNER,KATHLEEN DIANE,SECRETARY GARNER,KATHLEEN DIANE,TREASURER GARNER,JAMES NICHOLAS,AGENT SMITH,PAMELA (End:01/01/1980) GARNER,PAUL MILTON,PRESIDENT (End: 10/01/2012) Doing business as C M HEATING INC WA UBI No. Business type 601 114 652 Corporation Governing persons JAMES GARNER PAUL M GARNER; KATHLEEN GARNER; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. CMHEAI"095R4 Effective—expiration 12/24/1991—05/03/2019 Bond CBIC $12,000.00 Bond account no. 655840 Received by L&I Effective date 04/24/2002 12/01/2001 Expiration date Until Canceled Insurance Ohio Security Ins Co $1,000,000.00 Policy no. Help us improve https://secure.ini.wa.gov/verify/Detail.aspx?UBI=601114652&LIC=CMHEAI*095R4&SAW= 1/3 7/18/2017 C M HEATING INC BKS55127154 Received by L&I Effective date 04/20/2017 05/03/2016 Expiration date 0 510 3/2 01 8 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No W tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations Infraction no. PBATI01045 Satisfied Issue date RCW/1NAC 06/16/201 d 18.106.020 Violation city Violation amount MOUNTLAKE TERRACE $250.00 Type of violation PLUMBER INFRACTION Description Contractor employed a person to engage in the trade of plumbing without a current journeyman,specialty or trainee certificate, temporary permit or medical gas endorsement as required.C M Heating employed Thomas Andrew Holden to perform plumbing installation work;Installed a new gas water heater,when not certified as a plumber as required. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 490,794-01 Doing business as CHIMNEY MASTERS Estimated workers reported Quarter 1 of Year 2017"31 to 50 Workers" L&I account contact T2 I MATT PEDERSEN(360)902-5476-Email:PEDM235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ................................................... No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 0 3/1 612 01 5 No violations Inspection no. 317935327 Location 1415 Broadway Everett,WA 98201 https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=601114652&LIC=CMHEAI*095R4&SAW= 2/3 7/18/2017 C M HEATING INC Inspection results date 08/01/2011 Violations Inspection no. 315054981 Location 912 Rucker Everett,WA 98201 ©Washington State Dept,of Labor&Industries.Use of this site Is subject to the laws of the state of Washington. Help us improve https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=601114652&LIC=CMHEAI*095R4&SAW= 3/3 i Goc.lgleMaps Olympic Ave �s Goog : • • Maps 425 N Olympic Ave Goog _ �- i v . P cx CL F � H .J I b ZI- N deceived JUL. 1. 8 2017 Ps I /Z- VDAIKIN V,X 12,N M VJ LA �P��O ! P M'C�b �9 [QJ Daikin City Your access to and use of the Daikin web site is subject to the Terms pad Conditions and all applicable laws. CAD CART(0) By Keyword All Cat odes>Sin41e Zone Systems>Sinq a Zone Hcat Py,r�,_qutdoor Unit>5(nafe Zone Heat Pumo Outdoor Units-RX Series>Model Number RX12NMVJU MODEL NUMBER RXI2NMVIU, 1.0-TON WALL MOUNTED UNIT Request Information I Add to CAD Cart Printable Pane Download POF Email This Paao DOWNLOADS �I Qsvit Famiiv Download I I VIEW CAD DRAWING I - - - 113 Specifications Dimensions Features Benefits Frequency - -- - 60 Hz -- --— — - - — - Voltage 208-230 V 2D Front View Current 4.14-3,74/4.99-4,50 A Cooling Capacity 10900 Btulh Airflow Rate(H) 31.3/26-1 m3/min 1105/922 ft3/min 2D Left Side View Maximum Air Flow-Cooling 1105 ft3/min Maximum Air Flow-Heating 922 W/min I 1 h Minimum Air Flow-Cooling 865 ft3/min 2D Riuht Side View Minimum Air Flow-Heating 777 ft3/min _ Compressor Type Hermetically Sealed Swing Type -— 2D Too View Compressor Model 1YC23AUXD Compressor Motor Output 790 W I � Refrigerant Oil Type FVC50K 1111--Illl _ 2D Bottom View Refrigerant Type R-410A Refrigerant Charge 2.09 lb 0 95 kg Fan Type Propeller 2A_8ack Viey+ 14 r 1 i/ !Y ICI24q µUS CQ6)- keAk cis �' Pq 2-12 Fan Motor Output 18 W Power Consumption(Rated) 843-843/1013-1013 W - ( � Power Factor 97.9-98.0/97.6-97.9% Sound Pressure Level(H)-Cooling 49 dBA Sound Pressure Level(H)-Heating 49 dBA Drawing No. C:3D093559A Sensible Capacity 9480 Btu/h Heating Capacity 13500 Btu/h Cooling Input Power 0.874 kW Heating Input Power 1.041 kW Max/Mln Cooling Capacity 13300/4400 Btu/h Max/Min Heating Capacity 16400/4400 Btu/h — — — -- Rated Cooling Conditions Ambient ff DBIWB):95/75 Indoor IT DB/WB):80/67 Rated Heating Conditions Ambient(T DBIWB):47 143 Indoor(°F DB/WBJ:70/60 Power Supply 208-230 V/60 Hz/1 Phase Heat Insulation Both Liquid and Gas Pipes Moisture Removal 0.45 gaith Starting Current 5.24 A Weight 60 Ib 27 kg Gross Weight 71 lb 32 kg Your access to and use of the Daikin web site is subject to the Terms and Conditions and all applicable laws. II IMF This combination qualifies for a Federal Energy Pau an ILI CERTIFIED' Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2016. Certificate of Product Ratings AHRI Certified Reference Number: 8064266 Date: 7/18/2017 Product:Variable Speed Mini-Split Heat Pump,with Remote Outdoor Unit Air-Source, Free Delivery Outdoor Unit Model Number: RX12NMVJU Indoor Unit Model Number: FTX12NMVJU Manufacturer: DAIKIN AC(AMERICAS), INC. jt Trade/Brand name: DAIKIN Series name: Manufacturer responsible for the rating of this system combination is DAIKIN AC (AMERICAS), INC. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source w Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity(Btuh): 10900 EER Rating (Cooling): 12.50 _ J13500 SEER Rating (Cooling):tHeafing ng Capacity(Btuh) @ 47 F:7IVHSPF Rating (Heating city(Stuh) @ 17 F: 6100 I ! II CERTIFIED RATINGS FOR VARIABLE—SPEED,MINI—AND MULTI—SPLIT SYSTEMS ARE VALID FOR ALL COMBINATIONS OF INDOOR UNITS (BASED ON COMBINATION TYPES)WITH THE SPECIFIC OUTDOOR UNIT LISTED ABOVE AND IN THE AHRI DIRECTORY OF CERTIFIED EQUIPMENT.VISIT WWW.AHRIDIRECTORY.ORG TO VERIFY THAT THIS COMBINATION IS AN ACTIVE LISTING AND THE DATA LISTED ON 1 THIS CERTIFICATE IS ACQYH,1 F SF,eft,:;I ON THE AHRI ?i i-IL=! _-ICE#TO QUk .L(LOCATE THIS CpMBINP�TIQN IN FiiF— DIRECTORY. Ratings followed by an aster sk O " + a rerate of previously II; ,i- da,unless accon . :,.l wd11 a'NAS,whit r;scales an nv untary DISCLAIMER -� - '� ••---------__..� AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridIreotory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI.This Certificate shall only be used for Individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered Into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's Individual, .o +R personal and confidential reference. AMCONDRIONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The Information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we make life better" � and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which Is listed above,and the Certificate No.,which is listed at bottom right. ©=4 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 131448693184161900 q WS�C eompkn,ce Form, Equipment Size Category Minimum Efticlency Heating Section Sub-Category or Rating Teat Type Type Condition Before After procedure 11112017 111/2017 VRF <135,000 Btu/h VRF Multi-split System ARR1 1230 Groundwater (cooling Capacity) 50°F entering water 3.6 COP source (healing mode) ?135,000 Btuth VRF Multi-split System (cooling capacity) ... 50°F entering water 3.3 COP VRF <135,000 Btu/h VRF Multi-split System AHRI 1230 Ground source (cooling capacity) - 32°F entering water 3.1 COP (healing mode) 1135,000 Btu/h VRF Multi-split System (cuoling capacity) 32°F entering water 2.8 COP TABLE C403.2.3(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS EQUIPMENT TYPE SIZE CATEGORY HEATING SECTION SUBCATEGORY OR MINIMUM TEST TYPE RATING CONDITION EFFICIENCY PROCEDURE' Air cooled Split System 14.0 SEER <65,000 Btu/h' Ali (cooling mode) Single Packaged 14.0 SEER Through-the-wall, n Split System 12.0 SEER ARRI air cooled(cooling mode) <30,000 Btu/h All 210/240 Single Packaged 12.0 SEER Small duct high velocity,air coo led <65,000 Btu/hb All Split System I I.0 SEER Electric Resistance Split System and 11.0 EER >65,000 Btulh and (or None) Single Package 12,2 LEER <135,000 Btu/h Split System and 10.8 EER All other Single Package 12.0 TEER Electric Resistance Split System and 10.6 EER Air cooled ? I35,060 Btu/h (or None) Single Package 11.61EER AHRI (cooling mode) and<240,000 — — 340/360 Btu/11 All other Split System and 10.4 EER Single Package 11.4IEER Electric Resistance Split System and 9.5 EER z4o,000 Bn,n� (or None) Single Package 10.6 LEER > All other Split System and 9.3 EER Single Package 10.4 LEER <17,000 Btu/h All 86°F entering water 12.2 EER >_17 000 Bttl/li and Water source <65,000 Bluth All 86°F entering water 13.0 EER (cooling mode) >_65,000 Btu/h and All 86°F entering water 13.0 EER < 135,000 Btu/h ISO 13256-1 Ground water source <135,000 Btu/h All 59°F entering water 18.0 EER (cooling mode) Ground source <135,000 Btu/h . All 77°F entering water 14.1 EER (cooling made) g Water=sourcc water to water <135000 Btu/h All 86°F entering water 10.6 EER , (cooling mode) 59°F entering water 1G.3 EER Ground water source ISO 13256-2 Brine to water <135,000 Btu/h All 77°F entering fluid 12.1 EER (cooling mode) (�:otNnruerl� 2015 Washington Stale Energy Code CE-39 � I 0 � A�A VI 2 4 � H 440 -Z L I � T a 2 ► �: i Receive JUL 1-8 201 ;�,9 199b PS 1 /Z !"'DAIK/N M YV L1 GQV ( PM-e JSpeQ$ [M Daikin City Your access to and use of the Daikin web site is subject to the Terfns.3nsiConditions and all applicable laws. CAD CART(0) I By Keyword- All Categories>8inglt`Zgng_Svstems>Sinale Zone Heat Pump Outdoor Units> gI�Z94e Heat Pumy Qutdoor Units-RX Series>Model Number RX12NMVJU MODEL NUMBER RXI2NMVJU, 1.0-TON WALL MOUNTED UNIT Request Information Add to CAD Cart Printable aan° Download PDF Email Tins Pa --- DOWNLOADS---A �� Bsril.EatnilY Rgxmis�d li �.- LVIEW CAD DRAWING Y , i F ��= Specifications Dimensions Features Benefits J Frequency 60 Hz Voltage 208-230 V 2D Fiont View Current 4.14-3.74/4.99-4.50 A Cooling Capacity — 10900 Btu/h �) Airflow Rate(H) 31.3/26.1 m3/min JI JI 1105/922 ft3/min 20 Left S de View Maximum Air Flow-Cooling 1105 ft3/min Maximum Air Flow-Heating 922 ftYrnin PB Minimum Air Flow-Cooling 865 ft3/min 2D Right Side View Minimum Air Flow-Heating 777 ft3/min — Compressor Type Hermetically Sealed Swing Type 2D Top View Compressor Model IYC23AUXD Compressor Motor Output 790 W if Refrigerant Oil Type FVC50K I _ 2D Bottom View Refrigerant Type R-410A Refrigerant Charge 2.09 lb tt 0.95 kg f Fan Type Propeller 20-Back View �t i r ICI Z.N AVs q c�.s 2-12 r:QVrzKk Fan Motor Output 18 W Power Consumption!Rated( 843-843/1013-1013 W ' tm _ r Power Factor 97.9-98.0/97.6-97.9% f{4y1tM4d Sound Pressure Level(H)-Cooling 49 dBA Sound Pressure Level(H)-Heating 49 dBA Drawing No. C:3D093559A Sensible Capacity 9480 Btu/h Heating Capacity 13500 Btu/h Cooling Input Power 0.874 kW Heating Input Power 1.041 kW Mex/Mln Cooling Capacity 13300/4400 Btu/h Max/Min Heating Capacity 16400/4400 Btu/h Ambient IT DB/WB):95/75 Rated Cooling Conditions Indoor(°F DB/WB):80/67 Rated Heating Conditions Ambient(°F DB/WB):47/43 Indoor(°F DB/WB):70/60 Power Supply 208-230 V/60 Hz/1 Phase Heat Insulation Both Liquid and Gas Pipes Moisture Removal 0.45 gal/h Starting Current 5.24 A Weight 60 Ib 27 kg 71 lb Gross Weight 32 kg Your access to and use of the Daikin web site Is subject to the IeLIl7s_.,' o Conditions and all applicable laws. ■ This combination qualifies for a Federal Energy Alta 00 *1 CERTIFIED" Efficiency Tax Credit when placed in service wwmatiri(lirecr between Feb 17,2009 and Dec 31, 20% Certificate of Product Ratings x AHRI Certified Reference Number: 8064266 Date: 7/18/2017 � Product: Variable Speed Mini-Split Heat Pump,with Remote Outdoor Unit Air-Source, Free Delivery i Outdoor Unit Model Number: RX12NMVJU Indoor Unit Model Number: FTX12NMVJU Manufacturer: DAIKIN AC (AMERICAS), INC. { Trade/Brand name: DAIKIN Series name: J Manufacturer responsible for the rating of this system combination is DAIKIN AC (AMERICAS), INC. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 10900 EER Rating (Cooling): 12.50 SEEpCapaceity(Btuh) "17F: 9.00 Hea3500 Reg .00 Hea100 =S CERTIFIED RATINGS FOR VARIABLE-SPEED,MINI-AND MULTI-SPLIT SYSTEMS ARE VALID FOR ALL COMBINATIONS OF INDOOR UNITS I (BASED ON COMBINATION TYPES)WITH THE SPECIFIC OUTDOOR UNIT LISTED ABOVE AND IN THE AHRI DIRECTORY OF CERTIFIED EQUIPMENT.VISIT WWW.AHRIDIRECTORY.ORG TO VERIFY THAT THIS COMBINATION IS AN ACTIVE LISTING AND THE DATA LISTED ON TH4S CERTIFICATE IS ACC�IRATE.SEARCH ON THE�HRI REFERPNCE#TO QUICKLY LOCATE�THI�C2MBINATION IN THE DIRECTORY. atings followed by an asterisk O mdtcane a voluntary rerate of prev ously Publisher data,unless accompanied with a WAS,whit In icales an Involuntary(Grata, IJ DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warrantles or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certlfled ratings are valid only for models and configurations listed In the directory at www.ahridirectory.org. TERMS AND CONDITIONS � "Imp This Certificate and Its contents are proprietary products of AHRI.This Certificate shall only be used for Individual,personal and ' confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; - �` , entered Into a computer database;or otherwise utilized,In any form or manner or by any means,except for the user's Individual, personal and confidential reference. AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The Information for the model cited on this certificate can be verified at www_ahrldlrectory.org,click on"Verify Certificate"link Ne make life better'° .� and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which Is listed above,and the Certificate No.,which is listed at bottom right. ©2014 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 131448693184161900 ft 4 W 5 C ovylian6e Form., Equipment Heating Section Sub-Category or Rating Test Type Size Category Minimum Eflletertcy Type Condition Before After Procedure 11i12017 1/1/2017 VRF <135,000 Btu/h VRF'Multi-split System ARRI 1230 Groundwater (cooling capacity) 50°F enterLtg water 3.6 COP source — -- (healing mode) >_135,000 Btuth VRF Multi-split System (coolhtg capacity) -- 50°F entering water 3.3 COP VRF <135,000 Bhdh VRF Multi-split System AHRI 1230 Ground source (cooling capacity) ••- 32°F en(eringwater 3.1 COP (healing mode) 1I35,000 Bhilh VRF Multi-split System (cooling capacity) - 32°F entering water 2.8 COP TABLE C403.2.3(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS EQUIPMENT TYPE SIZE CATEGORY HEATING SECTION SUBCATEGORY OR MINIMUM TEST a TYPE RATING CONDITION EFFICIENCY PROCEDURE Air cooled <65,000 Btu/hl' All Split System 14.0 SEER (cooling mode) Single Packaged 14.0 SEER Through-the-wall, b Split System 12.0 SEER A-HRI air cooled(cooling mode) <30,00013tu/lt All 210/240 Single Packaged 12.0 SEER Small duct high velocity,air cooled <65,000 Btu/hb All Split System 11.0 SEER Electric Resistance Split System and 11.0 EER >65,000 BtMi and (or None) Single Package 12.2 IEER <135,000 Btu/h Split System and 10.8 EER All other Single Package 12.0 IEER 135 Electric Resistance Split System and 10.6 EER Air cooled �000 Btu/h and<240,000 (or None) Single Package 11.6 IEER AH[u (cooling mode) Btu/11 Split System and 10.4 EER 340/360 All other Single Package 11.41EER Electric Resistance Split System and 9.5 EER >240,000 Btu/h (or None) Single Package 10.6 IEER All other Split System and 9.3 EER Single Package I0.4 LEER <17,000 Blu/h All 86°F entering water 12.2 EER >_17 000 Btll/I1 and Water source <�65,000 Blu/h All 86°F entering water 13.0 EER (cooling mode) 65,000 Btu/h and All 86°F entering water 13.0 EER < 135,000 Btu/h ISO 13256-1 Ground water source <135,000 Btu/h All 59°F entering water 18.0 EER (cooling mode) Ground source(cooling mode) <135,000 Btu/h . All 77°F entering water 14.1 EER Water source water to water <135,000 Btu/h All 86°F entering water 10.6 EER (cooling mode) 59°F entering water 16.3 EER ISO 13256-2 Ground water source Brine to water <135,000 Btu/h All 77°F entering fluid 12.1 EER (cooling mode) (emah"Wo 2015 Washington Stale Energy Code CE-39 Permit#: 1558 Permit Date: 07/18/17 Permit Type: COMMERCIAL MECHANICAL Project Name: Knudson Applicant Name: CM Heating, Inc. Applicant Address: 1415 Broadway Applicant, City, State, Zip: Everett,WA 98201 Contact: Deborah Bauers Phone: 425-259-0550 Email: debbie@cmheating.com Scope of Work: Install Ductless Heat Pump Valuation: 5350.00 Square Feet: 0 Number of Stories: 1 Construction Type: Occupancy Group: ID Code: Permit Issued: 08/11/2017 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00529900701701 427 N OLYMPIC AVENUE PODNER 539 Other Retail PROPERTIES LLC Trade NEC Contractors Contractor Primary Contact Phone Address Contractor Type License License# CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Plumbing CMHEAHL750LP ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Construction CMHEAHL751 W ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION UBI 605890285 ST STE 200 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status C10. 08/25/2017 MECHANICAL 08/25/2017 z.Rick Karns Approved ROUGH-IN Plan Reviews Date Review Type Description Assigned To Review Status 07/18/2017 COMMERCIAL z.Rick Karns MECHANICAL Fees Fee Description Notes Amount Heat Pump/Heat Exchangers $25.00 Mechanical Base Permit Fee $25.00 Mechanical Commercial Plan Review Table 4-1 $200.00 Processing/Technology $25.00 Total $275.00 Attached Letters Date Letter Description 08/11/2017 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 08/08/2017 Debbie Bauers 65852724 cc $275.00 Outstanding Balance $0.00 Notes Date Note Created By: 08/08/2017 No screening is required for the unit as it is located next to another existing unit. Kristin Foster Uploaded Files Date File Name 08/14/2017 2523420-1558 Issued Permit.pdf 07/18/2017 2456892-1558 Specs&Plans.pdf 07/18/2017 2456893-1558 Application.pdf