Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
8002 EAGLEFIELD DR_BLD1659_2026
RESIDENTIAL MECHANICAL PERMIT APPLICATION t�N Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:8002 EAGLEFIELD DRIVE Project Description:INSTALL DUCTLESS HEAT PUMP WITH 2 INDOOR HEADS Owner: GINA JONES Address. 8002 EAGLEFIELD DRIVE City. ARLINGTON State.WA Zip Code: 98223 Phone. 425-244-3184 Email:GINA6811@HOTMAIL.COM Applicant: BARRON HEATING Address: 5100 PACIFIC HIGHWAY City. FERNDALE State.WA Zip Code: 98248 Phone. 360-676-1131 Email: COLLEENM@BARRONHEATING.COM CONTRACTOR INFORMATION Contractor Name:BARRON HEATING Address: 5100 PACIFIC HIGHWAY City. FERNDALE State.WA Zip Code: 98248 License Number: BARROHA179D7 Expiration: 10/23/18 Phone: 360-676-1131 Email:COLLEENM@BARRONHEATING.COM STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 y. RESIDENTIAL MECHANICAL PERMIT APPLICATION SING Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES ❑ Furnace (80+) Model # AFUE Heat Pump Model #MXZ3C24NA AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: [El Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: Date: 09/15/2017 Applicant Printed Name: COLLEEN MYERS I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 ` PHONE; (360)403-3551 BUILDING PERMIT Address:8002 Eaglefield Drive Permit#:1659 Parcel#:00865900010600 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:JONES STEVE&MILLER GREGORY Name:Barron Heating Name:BARRON HEATING&A.C. LYNN Address:8002 EAGLEFIELD DR Address:5100 Pacific Highway Address:5100 Pacific Highway#103 City,State Zip:ARLINGTON,WA 98223 City,State Zip:Ferndale,WA 98248 City,State Zip:Femdale,WA 98248 Phone: Phone:360-676-1131 Phone:360-676-1131 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:BARRON HEATING&A.C. Name: Address:5100 Pacific Highway#103 Address: City,State,Zip:Ferndale,WA 98248 City,State,Zip: Phone:360-676-1131 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRC l 10. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the Ci -lingto ust be reported on your sales tax return form and coded City of Arlington#3101. L7—/ Signature Print Name Date 1—GleAsed By Date CONDITIONS Approved as submitted. Additional requirements: Provide 3" concrete pad with seismic bracing attached to pad; provide electrical disconnect; lines shall be insulated -the use of adhesive tape is not permitted. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC,)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 9/18/2017 Heat Pump $25.00 9/18/2017 Mechanical Permit Base Fee $25.00 9/18/2017 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Community and Economic Development , Building Division INSPECTION RECORD SHALL REMAIN AT JOB Building construction shall not commence until permit SITE holder or agent has posted this Inspection Record Card in a conspicuous place on the premises. OWNER: Steve Jones and Lynn Gregory Miller CONTRACTOR: Barron Heating and A/C JOB ADDRESS:8002 Eaglefield Drive OWNERADDRESS: 8002 Eaglefield Drive USE of BUILDING: SFR PLAT NAME: Description of Work: Install Ductless Heat PUMP LOT# PERMIT NO: 1 659 Sprinklered: CONDITIONS: See Permit DATE ISSUED:9.18.2017 TYPE GROUP DEPARTMENT INSPECTION DATE DATE PASS FAIL INITIALS FOOTING BUILDING FOUNDATION INSPECTION LINE UNDERFLOOR (360)403-3417 SHEARWALL PLUMBING (groundwork) GAS PIPING(groundwork) ROUGH PLUMBING ROUGH GAS PIPING ROUGH HEATING&VENTILATION FRAMING INSULATION WALLBOARD(SHEAR/RATING) ROOF DRAINAGE DEVELOPMENT STORM INFILTRATION SERVICES GRADING INSPECTION LINE CURB GUTTER&SIDEWALK (360)403-3417 LANDSCAPE DRIVEWAY UTILITIES SIDE SEWER INSPECTION LINE SEWER CLEANOUT/FINAL (360)403-3508 WATER SERVICE INSPECTION WATER SERVICE FINAL CROSS CONNECTION FINAL (360)403-3417 FINAL INSPECTION All sections must be signed off prior to final inspection Electrical must be signed off prior to final inspection COMMENTS: SUBMITTAL DATA: 1 1 I M-SERIES MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM AWlk ELECTRIC Job Name: System Reference: Date: 0 ���IiIIIIIIIIIIIIIIIIIIImI��, � dIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII ij IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII6 h 'ILIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIP' Outdoor Unit:MXZ-3C24NA ACCESSORIES ❑ 3/8"x 1/2"Port Adapter(MAC-A454JP-E) ❑ 1/2"x 3/8"Port Adapter(MAC-A455JP-E) ❑ 1/2"x 5/8"Port Adapter(MAC-A456JP-E) ❑ M-NET Adapter(PAC-IF01 MNT-E) ❑ Base Heater(PAC-645BH-E) (For data on specific indoor units,see the MXZ-C Technical and Service Manual.) Specifications Model Name Unit Type MXZ-3C24NA Rated Capacity Btu/h 22,000/23,600 Cooling* Capacity Range Btu/h 12,600-22,000/12,600-25,500 (Non-ducted/Ducted) Rated Total Input W 1,620/2,100 Rated Capacity Btu/h 25,000/24,600 Heating at 47°F* Capacity Range Btu/h 11,400-30,600/11,400-29,400 (Non-ducted/Ducted) Rated Total Input W 1,750/1,900 Heating at 17°F* Rated Capacity Btu/h 14,000/14,000 (Non-ducted/Ducted) Rated Total Input W 2,120/2,230 Energy Star®(ENERGY STAR products are third-party certified by an EPA-recognized Certification Body.) Yes Power Supply Voltage,Phase,Hertz 208/230V, 1-Phase,60 Hz Electrical Requirements Recommended Fuse/Breaker Size A 25 MCA A 22.1 Voltage Indoor-Outdoor S1-S2 V AC 208/230 Indoor-Outdoor S2-S3 V DC±24 Compressor INVERTER-driven Scroll Hermetic Fan Motor(ECM) F.L.A. 1.9 Sound Pressure Level Cooling dB(A)A) 51 (Non-ducted/Ducted) Heating 55 External Dimensions(H x W x D) In(mm) 31-11/32 x 37-13/32 x 13 (796 x 950 x 330) Net Weight Lbs(kg) 135(61) External Finish Munsell 3.OY 7.8/1.1 Refrigerant Pipe Size O.D.— Liquid(High Pressure) In(mm) 1/4(6.35) Eight Ports I Gas(Low Pressure) A Port: 1/2(12.7);Other:3/8(9.52) Max.Refrigerant Line Length Ft(m) 230(70) Max.Piping Length for Each Indoor Unit Ft(m) 82(25) Max.Refrigerant Pipe Height If IDU is Above ODU 49(15) Difference If IDU is Below ODU Ft(m) 49(15) Connection Method 111 hL I Flared/Flared Refrigerant R41 OA *Rating Conditions per AHRI Standard: Cooling I Indoor:80'F(271 C)DB/67*F(19'C)WB Heating at 47T I Indoor:700 F(21'C)DB/60'F(160 C)WB Heating at 17D F Indoor:70'F(21°C)DB Cooling I Outdoor:950 F(350 C)DB/23.9°C(75'F)WB Heating at 47DF I Outdoor:470 F(80 C)DB/430 F(60 C)W B Heating at 170 F Outdoor:170 F(8°C)DB/150 F(9°C)WB Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. SPECIFICATIONS: • I 1 OPERATING RANGE ENERGY EFFICIENCIES Outdoor Indoor Unit Type SEER EER HSPF COP @ COP 47°F @ 17°F Cooling 14 to 115°F(-10 to 46°C)DB Non-ducted 20.0 13.6 9.8 4.2 2.97 Heating 5 to 65°F(-15 to 18°C)WB (06+06+09) Ducted and 18.0 12.4 9.5 4.0 2.79 Non-ducted Ducted 16.0 11.2 9.2 3.8 2.61 (09+09+09) NOTES: • Minimum of two Indoor Units must be connected to the MXZ-3C24NA. • Minimum installed capacity cannot be less than 12,000 Btu/h. • Total connected capacity must not exceed 130%of outdoor unit capacity. • System can operate with only one Indoor Unit turned on. • Information provided at 208/230V. • For Reference: MXZ-C Technical&Service Manual for detailed specifications and additional information per Indoor Unit Combination. MXZ Series Multi-Zone Indoor/Outdoor Combination Table for allowed unit combinations. MVZ CONNECTION RULES: • Only 1 MVZ may be used on any system. • When an MVZ is connected,total connected capacity must be 100%or less. • When an MVZ is connected,no P-Series indoor units can be used(PCA,PLA,or PEAD). Notes: Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. I 1 OPERATIONAL 1 • 1 PERFORMANCE DUCTED: Operational Cooling IndoorPerformance for Unit Combinations Unit A Unit B Unit C 9 9000 0 1 0 10900 0 0 12 12000 0 0 13600 0 0 15 15000 0 0 18000 0 0 18 17200 0 0 21600 0 0 9+9 9000 9000 0 10900 10900 0 9000 12000 0 9+12 TBD 9429 12571 0 9+15 8175 13625 0 9000 15000 0 9+18 7267 14533 0 8000 16000 0 12+ 12 10900 10900 0 12000 12000 0 12+ 15 9689 12111 0 10667 13333 0 9+9+9 7867 7867 7867 8200 8200 8200 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. NON-DUCTED: Operational Cooling IndoorPerformance for •. is O Unit Combinations Unit A Unit B Unit C 6 6000 0 0 7400 0 0 9 9000 0 0 11000 0 0 12 12000 0 0 14400 0 0 15 14000 0 0 18000 0 0 18 17200 0 0 21600 0 0 6+6 6000 6000 0 7400 7400 0 6+9 6000 9000 0 7360 11040 0 6+ 12 6000 12000 0 7333 14667 0 6+15 5714 14286 0 6286 15714 0 6+18 5450 16350 0 6000 18000 0 9+9 9000 9000 0 11000 11000 0 8571 11429 0 9+ 12 TBD 9429 12571 0 9+ 15 8175 13625 0 9000 15000 0 9+18 7267 14533 0 8000 16000 0 12+ 12 10900 10900 0 12000 12000 0 12+ 15 9689 12111 0 10667 13333 0 6+6+6 6000 6000 6000 7400 7400 7400 6+6+9 6000 6000 9000 7086 7086 10629 6+6+ 12 5500 5500 11000 6250 6250 12500 6+6+ 15 5333 5333 13333 5556 5556 13889 6+9+9 5500 8250 8250 6250 9375 9375 6+9+ 12 5333 8000 10667 5556 8333 11111 9+9+9 8000 8000 8000 8333 8333 8333 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. DIMENSIONS: 1 Unit: inch (mm) 6-7/8' 23-5/8' 6-7/8' OR—Air fake 2-13/16' 9-1/16' 4-19/32" 2-1/32" 3-1/16' 2-U Shaped Notched Hole 13/32" (Foundation Bolt 11101 Sid.Air Intake b m 6-m1-5/16"Drain Hole N 13/32" b o s�hnrge 2-(15/32"x1-13/32")Oval Hole 1-1/32" 2-07/8'knockout hole (Foundation Bolt H10) 1-1/2' 1 ...cfin wire hole) 1-5/8' 37-13/32' 31/32' 13" 19/32" rl'lonn/. 78punched holecting wire hole) Hnnd(e \ Handle Ol P V Hantlle Hontlle 0 2-3/4" O® Air Intake =CalGAS}Unif C Llp 1/L'(06.351FLARE O® GAS}Unif g GAS 1/1109.52IFLARE O® Lla 1 LIG 1/L'(012.7)FLARE ,fU�IrBP11 GAS}Unil A— GAS 1/2'(012.]IFLARE v1-11131 14-7/32' 1.FREE SPACE E E E 3-15/16" or more LIQ 777T7 3-15/16' or more7r,325,32' or more Conduit plates 2.SERVICE SPACE E2. v L L Conduit connector _ yy� Lock nut 3-15116" or more FF SERVICE SPACE 13-25132" or more 13-25/32" or more MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com ETA us FORM#MXZ-3C24NA for Multiple Indoor Unit Styles-201605 Intertek Specifications are subject to change without notice. ©2015 Mitsubishi Electric US,Inc. Permit#: 1659 Permit Date: 09/18/17 Permit Type: RESIDENTIAL MECHANICAL Project Name: Jones Applicant Name: Barron Heating Applicant Address: 5100 Pacific Highway Applicant, City, State, Zip: Ferndale, WA 98248 Contact: Colleen Myers Phone: 360-676-1131 Email: colleenm@barronheating.com Scope of Work: Install Ductless Heat Pump Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning JONES STEVE& 111 Single Family 00865900010600 8002 EAGLEFIELD DR MILLER GREGORY Residence-Detached LYNN Contractors Contractor Primary Contact Phone Address Contractor Type License License# BARRON HEATING MAKENNA 5100 PACIFIC CONSTRUCTION &AC INC STEINKAMP 360-676-1131 HWY STE 103 CONTRACTOR COA 600092564 BARRON HEATING MAKENNA 5100 PACIFIC CONSTRUCTION LABOR& &AC INC STEINKAMP 360-676-1131 HWY STE 103 CONTRACTOR INDUSTRIES BARROHA179D7 Plan Reviews Date Review Type Description Assigned To Review Status 09/18/2017 RESIDENTIAL z.Rick Karns MECHANICAL Fees Fee Description Notes Amount Heat Pump/Heat Exchangers $25.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Total $75.00 Attached Letters Date Letter Description 09/18/2017 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 09/18/2017 WILLIAM PINKEY 66443961 cc $75.00 Outstanding Balance $0.00 Uploaded Files Date File Name 10/04/2017 2673863-Please cancel permit- 1659.msg 09/18/2017 2610237-1659 Apnlication.pdf 09/18/2017 2610238-1659 Specs.pdf 09/18/2017 2610178-1659 Specs.pdf 09/18/2017 2610179-1659 Apnlication.pdf