Loading...
HomeMy WebLinkAbout208 N LENORE AVE_BLD1837_2026 NOTICE " ` TO PERMITEE AND/OR OWNER )k` ��`I ❑ PARTIAL APPROVAL O CORRECTIONS REQUIRED ❑ DO NOT OCCUPY O-OPROVED PERMIT#: ILOT#: I DATE: JOB ADDRESS: 1 Z \ TYPE OF INSPECTION: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT:AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK: MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE IT. ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. Cl CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION I THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE O BUILDING DEPT. 0 PLANNING DEPT. CITY OF ARLINGTON ' MISCELLANEOUS PERMIT APPLICATION Department of Community& Economic Development City of Arlington•18204 59th Ave NE•Arlington,WA 98223 • Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR INTERIOR ALTERATIONS FENCES, RETAINING WALLS, STORAGE TANKS, PLAYGROUND EQUIPMENT, POOLS, HOT TUBS, ETC. Project Address: Project Description: Valuation: Owner: ( I Q►'1 ��l ►' l Address: �/�� GVJ City: State: Zip Code: Phone: ��LLj'7 S - zi 15 Email: Applicant: �)CIMC G5 Nmne,f Address: City: State: Zip Code: Phone: Email: Contractor Name: Tfj OV 14 __ �TEi�P L C .S Address: J� ZUS 3 f�. �r 5 L City. Bc;f k e, State: �, Zip Code: Phone: '4 Z5- 2_2r? - / 7 4T2 Email: !'� �•. �' �t.S' /I Z'i�rl�c�c.I7 /1 License Number: RJr o'TE 126- /?-S Expiration Date: 2-0 19 I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. App,, �'gn�ur� Date Print Applicants Name FOR STAFF USE ONLY Received W FEB 1. 2 ?01R Permit# A cepted By Amount Received Receipt# Date Received IWORQ Systems Inc. Page 1 of 2 r ' CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:208 N.Lenore Avenue Permit#:1837 Parcel#:00455400 101100 Valuation:50000 00 OWNER APPLICANT CONTRACTOR Name:SMITH JOEL&ELLEN Name:Joel and Ellen Smith Name:RJ Thomas Enterprises,LLC Address:208 N LENORE AVE Address:208 N Lenore Ave Address: 15205 38th Drive SE City,State Zip:ARLINGTON,WA 98223-1414 City,State Zip:Arlington,WA 98223 City,State Zip:Bothell,WA 98012 Phone: Phone:425-971-2415 Phone:425-220-1782 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Alteration CODE YEAR: 2015 STORIES: 1 CONST.TYPE: `/B DWELLING UNITS: 1 OCC GROUP: R3 BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 1 IOARC 110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in th CityofArlington must be reported on your sales tax return form and co d City of Arlington 3101. �f/ 7 j� �Aom �v1111011,03 Signatu Print Name Date Released By Dat CONDITIONS See red lined drawings. Adhere to approved plans. THIS PERMIT AUTHORIZE ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 4/18/2018 Building Permit Fee $929.93 4/18/2018 Building Plan Review Fee $604.45 4/18/2018 Plumbing Permit Base Fee $25.00 4/18/2018 Plumbing Permit Fee(Enter Fixture Fee) $36.00 4/18/2018 Processing/Technology Fee $25.00 4/18/2018 State Building Code Surcharge Fee $4.50 Total Due: $1,624.88 Total Payment: $1,624 88 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 https://www.iworq.net/iworq/permit/popupPermitEditLetterPrint.asp?sid=OKGFBOOMP... 4/18/2018 NOTICE "'V` TO PERMITEE AND OR OWNER )x-,` C I I ❑ PARTIAL APPROVAL Cl CO�R ECTIONS REQUIRED ❑ DO NOT OCCUPY 'APPROVED PERMIT#: lq)7- LOT#: DATE: c� JOB ADDRESS: ' TYPE OF INSPECTION: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT:AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK: MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE IT. ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 Cl CALL FOR REINSPECTION THEACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BY LAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE Cl BUILDING DEPT. Cl PLANNING DEPT. CITY OF ARLINGTON • IWORQ Systems Inc. Page 1 of 2 CITY OF ARLINGTON �\ 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:208 N.Lenore Avenue Permit#:1837 Parcel#:00455400101100 Valuation:50000.00 OWNER APPLICANT CONTRACTOR Name:SMITH JOEL&ELLEN Name:Joel and Ellen Smith Name:RJ Thomas Enterprises,LLC Address:208 N LENORE AVE Address:208 N Lenore Ave Address: 15205 38th Drive SE City,State Zip:ARLINGTON,WA 98223-1414 City,State Zip:Arlington,WA 98223 City,State Zip:Bothell,WA 98012 Phone: Phone:425-971-2415 Phone:425-220-1782 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Alteration CODE YEAR: 2015 STORIES: I CONST,TYPE: VB DWELLING UNITS, 1 OCC GROUP: R3 BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in th Cit�,of Arlington must be reported on your sales tax return form ecoand d City of Arlin 3101. arn gtoi �v Signa.tu Print Name Date Released By Dat CONDITIONS See red lined drawings. Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 4/18/2018 Building Permit Fee $929.93 4/18/2018 Building Plan Review Fee $604.45 4/18/2018 Plumbing Permit Base Fee $25.00 4/18/2018 Plumbing Permit Fee(Enter Fixture Fee) $36.00 4/18/2018 Processing/Technology Fee $25.00 4/18/2018 State Building Code Surcharge Fee $4.50 Total Due: $1,624.88 Total Payment: $1,624 88 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 https://www.iworq.net/iworq/permit/popupPermitEditLetterPrint.asp?sid=OKGFBOOMP... 4/18/2018 IWORQ Systems Inc. Page 2 of 2 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon https://www.iworq.net/iworq/permit/popupPennitEditLetterPrint.asp?sid=OKGFBOOMP... 4/18/2018 Permit Information Date 2/13/2018 Permit Number 1837 Project Name Smith Applicant Name Joel and Ellen Smith Applicant Address 208 N Lenore Ave City,State,Zip Arlington,WA 98223 Contact Joel Smith Phone 425-971-2415 Email joelenplus3@yahoo.com Permit Type Residential Alteration Site Address 208 N.Lenore Avenue Valuation 50000.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 2 Proposed Use Interior remodel Assigned To Kristin Foster Property Parcel Address Legal Owner Owner Phone Zoning 00455400101100 208 N LENORE AVE SMITH JOEL&ELLEN 111 Single Family Residence-Detached Contractors Contractor Name Primary Phone Email Contractor License License# Contact Type RJ Thomas Enterprises, 425-220- Labor and ILLC 1782 robertthomasll@comcast.ne CONTRACTOR Industries IRJTHOTE905RS Review Date Type Description I Target Date I Completed Date I Assigned To I Status 2/13/2018 Residential Renovation 2/20/2018 1 lKevin Olander 111n Review Fees Fee Description Notes Amount Building Plan Review Feel 345.83.00.00 $604.46 Totall $604.4 Uploaded Files Upload File Date I File Uploaded By I 2/13/2018 10:38:55 AM 11837 Application.pdf Foster,Kristin �( ' MISCELLANEOUS PERMIT APPLICATION Department of Community&Economic Development City of Arlington•18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 TTTRTEAPPLICATION SIRET NQNP ALTERATIONS AII RETAINING WALLL , STOAG TANKS, PLAYGROUNDD WHEN APPLYING EQUIPMENT, POOLS, O TUBS, EC Project Address: Project Description: Valuation: �.�C>, ,� {� L Owner: I �' �✓)(F n t`� �'� Address: V } � J� City: State: Zip Code: Phone: �'Z'S 1 - 2'�1 J Email: Applicant: Sc4ntG5 0nef Address: City: State: Zip Code: Phone: Email: Contractor Name: klu T/_0_M r L �.;, 6/TEi(�f'n Address: j� ZD 4-� r . 5 City: 8c,f(�a State: Zip Code: �j Z Phone: �t7_S- zt;7 - / 7H_ - Email: License Number_R Tffv'r"0,S_ /?S Expiration Date: 17// 12-011-f 1 hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. App (ig ure Date m % h Print Applicants Name FOR STAFF USE ONLY Permit# A cepted By Amount Received Receipt# Date Received 2/13/2018 RJ THOMAS ENTERPRISES LLC r i 1 c...., y......A t,ua..t earch L&I A-Z h.d.•c Ih•II. ?1 ]&C S�fe[y R He lFlj simrns&Inui nce Yforkf)lace RigWks Trdde5 Licensing Washington State Department of " Labor & Industries RJ THOMAS ENTERPRISES LLC Owner or tradesperson 15205 38TH DR SE THOMAS,ROBERT JAMES BOTHELL,WA 98012 425-220-1782 Principals SNOHOMISH County THOMAS,ROBERT JAMES,PARTNER/MEMBER THOMAS,ROBERT JAMES,AGENT THOMAS,ANN MARCIA,PARTNER/MEMBER (End:09/01/2017) WA UBI No. Business type 603 049 684 Limited Liability Company License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. RJTHOTE905RS Effective—expiration 12/10/2010—09/01/2019 Bond CBIC $12,000.00 Bond account no. S10483 Received by L&I Effective date 12/10/2010 11/22/2010 Expiration date Until Canceled Insurance Security National Insurance $1,000,000.00 Policy no. NA109222203 Received by L&I Effective date 09/19/2017 09/24/2017 Expiration date 09/24/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings https://secure.ini.wa.gov/verify/Detail.aspx?UBI=603049684&LIC=RJTHOTE905RS&SAW= 1/2 2/13/2018 RJ THOMAS ENTERPRISES LLC No lawsuits against the bond or savings unts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp No active workers'comp accounts during the previous 6 year period. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. ©Washington State Dept.of Labor&Industries.Use of this site is subject to the laws of the state of Washington. hftps://secure.Ini.wa.gov/verify/Detail.aspx?UBI=603049684&LIC=RJTHOTE905RS&SAW= 2/2 Alterations Worksheet 2015 Washington State Energy Code Project Information Contact Information ;woe I Olen 366 - 13 - 00&lc, The Washington State Energy Code requirements for alterations are located in Chapter 5 Alterations (remodels) do not need to obtain energy credits from Table R406.2 Additions must meet the requirements for new construction. This includes nonconditioned space being altered to become conditioned space. Will the wall cavities be exposed? Fv Yes >- No If yes: Exposed wail cavities must be insulated - 2 X 4 wall studs require R-15 insulation 2 X 6 wall studs require R-21 insulation Will the roof/ceiling framing cavities or attic be exposed? R Yes F' No If yes: Exposed roof/ceiling assemblies must be insulated - Vaulted ceilings: Insulate to the full depth of the framing member while allowing for the minimum 1" ventilated space Flat ceilings: Install R-49 insulation or what the attic space can accommodate based on the roof pitch Will the floor framing cavities be exposed? I✓ Yes 1- No If yes: Exposed floor cavities must be insulated to R-30 Are the windows and/or doors being replaced? R Yes f- No (includes both window or door and frames) If yes: New windows and doors must have an area weighted average U-factor of:50.30 Will the heating or cooling system be replaced? F Yes R No I ns�r-llecl r,e w r,mey � na+uMl as If yes: New equipment must meet current requirements and Corak 5 ducts need to be tested Will the hot water system be altered? F Yes F,, No I ns+r,IIe"A Jv e(1 5//9�/7 8r,Ac1 4,-rpl 6-0 g4/!cw) �-- ec-tr,t.:. If yes: New water heating equipment must meet current code requirements Are more than 50% of the light fixtures being changed? (�SO� g 9 g � Yes �` No If yes: 75% of all lamps must be high efficacy (LED or CFL) un i . , Jk LOLO If 1 /1 M M M M M M A- h1 I, II N 4 LU w o Rf1NaAV ElHON3'I a o w J m m Z Z S --- S - _ S S I � 0 ,91'LL� .9L'9Z ; ' _ (.0092) I ' C� $ W { ;a c) 00 0L N N r IW / A m 00 ,g� w � Coi DW I- V) o W I0) O N O L ^p N W CO 0 (- I I o � V! _ O 'cz I IM '9 I o .L I o S O N Q, -- co A .Z6'L I N 3„Z9,8 i.ON N W O Vl Ifn LO Z Z J I W Q I N i -d U_ 0 cr Q, '*I o ¢ z N 0 w� A W o]_ 00 ¢ m0 W �� C� Q � w o c� I ca Z (,00-IRO (,00.90 rn �� I (D � o 8l .0 `V N 1 I I I F_- LEGAL DESCR PTIONS LOT 11 BEFORE ADJUSTMENT LOT 11. BLOCK 1, GIFFORDS FIRST ADDITION TO ARLINGTON, ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 2 OF PLATS, PAGE 66, ftF!_)oi?DS OF SNOHOAIISIT COUNTY, WASHINGTON. SITUATE IN THE COUNTY OF SNOHOMISH. STATE OF WASHINGTON. LOT 12 BEFORE ADJUSTMENT LOT 12. BLOCK 1, GIFFORDS FIRST ADDITION TO ARLINGTON, ACCORDING TO THE PLAT THEREOF, RECORDED I'I VOLUME 2 OF PLATS, PAGE 66, RECORD SNOHOMISH COUNTY, WASHIIIGTON, S OF SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON. LOT 11 AFTER ADJUSTMENT -1!!E"�. ALL THAT PORTION OF LOTS 11 AND 12, BLOCK I. GIFFORDS FIRST ADDITION TO ARLINGTON, ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 2 OF PLATS, PAGE 66, RECORDS OF SNOHOMISH COUNTY, WASHINGTON, LUNG SOUTH AND EAST OF THE FOLLOWING DESCRIBED LINE: COMMENCING AT THE SOUTHEAST CORNER OF SAID LOT 11; THENCE NO18'52"E ALONG 111E EAST LINE OF SAID LOT 11 AND ITS NORTHERLY EXTENSION A DISTANCE OF 64.66 FEET TO THE TRUE POINT OF BEGINNING; 11-IENCF N89'37'00"W A DISTANCE OF 69.82 FEET; THENCE S45 20'56"W/ A DISTANCE OF 6.32 FEET; THENCE SO'18'S7."W A DISTANCE OF 60.21 FEET TO THE SOUTH LINE OF SAID LOT 11 AND THE TERMINUS OF HEREIN DESCRIBED LINE. BEING A PORTION OF THE NORTHEAST QUARTER OF THE NORTHEAST QUARTER OF SECTION 11. TOWNSHIP 31 NORTH, RANGE 5 EAST, W.M. SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON. LOT 12 AFTER ADJUSTMENT ALL THAT PORTION OF LOTS 11 AND 12, BLOCK 1. GIFFORDS FIRST ADDITION TO ARLINGTON. ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 2 OF PLATS, PAGE 66, RECORDS OF SNOHOMISH COUNTY, WASHINGTON, LYING NOR AND 1t�ST OF THE FOLLOWANG DESCRIBED LINE: TH COMMENCING AT THE SOUTHEAST CORNER OF SAID LOT 11; THENCE NO18'52"E ALONG THE EAST LINE OF SAID LOT 11 AND ITS NORTHERLY EXTENSION A DISTANCE OF 64.66 FEET TO THE TRUE POINT OF BEGINNING; THENCE N89'37'00"W A DISTANCE OF 69.82 FEET- THENCE S4520'56"W A DISTANCE OF 6.32 FEET; THENCE SO'18'52"Vl A DISTANCE OF 60.21 FEET TO THE SOUTH LINE OF SAID LOT 1) AND THE TERMINUS OF HEREIN DESCRIBED LINE. BEING A PORTION OF THE NORTHEAST QUARTER OF THE NORTHEAST QUARTER OF SECTION 11, TOWNSHIP 31 NORTH, RANGE 5 EAST, W.M. SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON_ 1 Recenved TR 1 [ Permit#: 1837 Permit Date: 02/13/18 Permit Type: RESIDENTIAL ALTERATION Project Name: Smith Applicant Name: Joel and Ellen Smith Applicant Address: 208 N Lenore Ave Applicant, City, State, Zip: Arlington,WA 98223 Contact: Joel Smith Phone: 425-971-2415 Email:joelenplus3@yahoo.com Scope of Work: Interior remodel Valuation: 50000.00 Square Feet: 0 Number of Stories: 2 Construction Type: Occupancy Group: ID Code: Permit Issued: 04/18/2018 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00455400101100 208 N LENORE AVE SMITH JOEL& 111 Single Family ELLEN Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# RJ Thomas Enterprises, 425-220 1782 15205 38th Drive CONSTRUCTION Labor and RJTHOTE905RS LLC SE CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 04/26/2018 R20.SFR/DUPLEX Approved FINAL Plan Reviews Date Review Type Description Assigned To Review Status 02/13/2018 RESIDENTIAL BUILDING ALTERATION Fees Fee Description Notes Amount Building Plan Review Table 4-2 $604.45 Building Permit Table 4-1 $929.93 Plumbing Base Permit Fee $25.00 Mechanical Commercial Permit Table 4-7;Per Unit $36.00 Processing/Technology $25.00 State Surcharge- 1st DU Residential- 1st Unit $4.50 Total $1,624.88 Attached Letters Date Letter Description 04/18/2018 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 04/13/2018 Joel Smith 69430911 cc $1,624.88 Outstanding Balance $0.00 Uploaded Files Date File Name 11/09/2018 4183877-1837 10-29-2018 Inspection Card.pdf 11/05/2018 4153977-External-Joel Smith for final inspection.msg 04/18/2018 3280498-1837 Issued Permit.pdf 02/13/2018 3035205-1837 Application.pdf • C Z %L � 4 x .,t Sfdr 91t1713D GxZ--y � LX ,. kU a41 r k40.[10 9 d Od 'W -� Zt 03 v) 16WILm, OD .. O Q a ' rz � 11 fl QcJ " � ) t U ( � kJ rf pM, , VN ev �f 3 , Q ry N ty Z •��d �iM r�aan/�rn '� J Z 4 , old 1 g / I �w o ,, 4 0 1 N.71�35�� a� a E h 00 QL E LLJ co OD, le _ 4 cc lk a .' w N j-j d 4 � N z¢ x ° V uj ` mod -O 's tea, N x � 3 � w x w W 3 -J W W " ;.. t J .d. �* .. n 1211, mm � q R - LU IUD l ,1.N3 f oX a�Qs �b7d3dJ-4 ,,, . 0 CL , u CL o 3/1 Ou3& 3 NV NV-7? t fn ID N i 71 svw .: V.� 9 00 .�e IT i �'� '4-S '7 1 d NI CV 17- u, t� h ODoc M •d+s g.7z N _ � p VNII.17d©,,b`,'£ .7/1 V�-1 OS O 4Z 9Z q M � 01. !9IVINIQ i , - (M7M2 OH b 0 x ' RO OX N try .,y Q ti fl0 u, (r13N� �7N 9 X�r N 00 i w M CD ` ,. O0 Q ,p N ..: 1rWO u� ------------- .,..ems.....,.�.........,..�..�.........e..�.,� ......,....�.......+.�.+n.«.�.-�.,,...........sm.�,...,.......a......-...u.......�-•.a. ,�.�.a..,.�..e..�.....,......�-.+�.- ..,..+ar....--....-.—..-..�...e : SECTION R406 2. Medium Dwelling Unit: .................. 3.5 credits ADDITIONAL ENERGY EFFICIENCY All dwelling units that are not included in#1 or REQUIREMENTS #3. i R406.1 Scope.This section establishes options for Exception: Dwelling units serving R-2 additional criteria to be met for one-and two-family occupancies shall require 2.5 credits. dwellings and townhouses,as defined in Section 101.2 3. Large Dwelling Unit: 4.5 credits of the International Residential Code to demonstrate Dwelling units exceeding 5000 square feet of compliance with this code. conditioned floor area. R406.2 Additional energy efficiency requirements Exception: Dwelling units serving R-2 (Mandatory).Each dwelling unit in a residential occupancies shall require 2.5 credits. building shall comply with sufficient options from 4. Additions less than 500 square feet:. 0.5 credits Table R406.2 so as to achieve the following minimum number of credits: The drawings included with the building permit application shall identify which options have been 1. Small Dwelling Unit: ........................1.5 credits selected and the point value of each option,regardless Dwelling units less than 1500 square feet in of whether separate mechanical,plumbing,electrical, conditioned floor area with less than 300 square or other permits are utilized for the project. feet of fenestration area. Additions to existing building greater than 500 square feet of heated floor area but less than 1500 square feet. TABLE 406.2 ENERGY CREDITS OPTION DESCRIPTION CREDIT(S) la EFFICIENT BUILDING ENVELOPE 1 a: 0.5 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U =0.28 Floor R-38 Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total UA by 5%. lb EFFICIENT BUILDING ENVELOPE lb: 1.0 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U =0.25 Wall R-21 plus R-4 Floor R-38 Basement wall R-21 int plus R-5 ci Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total UA by 15%. lc EFFICIENT BUILDING ENVELOPE lc: 2.0 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U =0.22 Ceiling and single-rafter or joist-vaulted R-49 advanced Wood frame wall R-21 int plus R-12 ci Floor R-38 Basement wall R-21 int plus R-12 ci Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total UA by 30%. Id' EFFICIENT BUILDING ENVELOPE 1d: 0.5 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U=0.24 RE-34 2015 Washington State Energy Code OPTION DESCRIPTION CREDIT(S) 2a AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2a: 0.5 Compliance based on R402.4.1.2: Reduce the tested air leakage to 3.0 air changes per hour maximum and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code shall be met with a high efficiency fan(maximum 0.35 watts/cfm),not interlocked with the furnace fan.Ventilation systems using a furnace including an ECM motor are allowed,provided that they are controlled to operate at low speed in ventilation only mode. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the maximum tested building air leakage and shall show the qualifying ventilations stem. 2b AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2b: 1.0 Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 2.0 air changes per hour maximum and All whole house ventilation requirements as determined by Section M 1507.3 of the International Residential Code shall be met with a heat recovery ventilation system with minimum sensible heat recovery efficiency of 0.70. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the maximum tested building air leakage and shall show the heat recove ventilations stem. 2c AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2c: 1.5 Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 1.5 air changes per hour maximum and All whole house ventilation requirements as determined by Section M 1507.3 of the International Residential Code shall be met with a heat recovery ventilation system with minimum sensible heat recovery efficiency of 0.85. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the maximum tested building air leakage and shall show the heat recovery ventilations stem. 3a HIGH EFFICIENCY HVAC EQUIPMENT 3a: 1.0 Gas,propane or oil-fired furnace with minimum AFUE of 94%,or Gas,propane or oiled-fired boiler with minimum AFUE of 92% To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 3b HIGH EFFICIENCY HVAC EQUIPMENT 3b: 1.0 Air-source heat pump with minimum HSPF of 9.0 To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 3c HIGH EFFICIENCY HVAC EQUIPMENT 3c: 1.5 Closed-loop ground source heat pump;with a minimum COP of 3.3 or Open loop water source heat pump with a maximum pumping hydraulic head of 150 feet and minimum COP of 3.6 To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 3d° HIGH EFFICIENCY HVAC EQUIPMENT 3d: 1.0 Ductless Split System Heat Pumps,Zonal Control: In homes where the primary space heating system is zonal electric heating,a ductless heat pump system shall be installed and provide heating to the largest zone of the housing unit. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 2015 Washington State Energy Code RE-35 OPTION DESCRIPTION CREDIT(S) 4 HIGH EFFICIENCY HVAC DISTRIBUTION SYSTEM: 1.0 All heating and cooling system components installed inside the conditioned space.This includes all equipment and distribution system components such as forced air ducts, hydronic piping,hydronic floor heating loop,convectors and radiators. All combustion equipment shall be direct vent or sealed combustion. For forced air ducts:A maximum of 10 linear feet of return ducts and 5 linear feet of supply ducts may be located outside the conditioned space.All metallic ducts located outside the conditioned space must have both transverse and longitudinal joints sealed with mastic.If flex ducts are used,they cannot contain splices.Flex duct connections must be made with nylon straps and installed using a plastic strapping tensioning tool. Ducts located outside the conditioned space must be insulated to a minimum of R-8. Locating system components in conditioned crawl spaces is not permitted under this option. Electric resistance heat and ductless heat pumps are not permitted under this option. Direct combustion heating equipment with AFUE less than 80%is not permitted under this option. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the heating equipment type and shall show the location of the heating and cooling equipment and all the ductwork. 5a EFFICIENT WATER HEATING 5a: 0.5 All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 GPM or less.All other lavatory faucets shall be rated at 1.0 GPM or less.` To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the maximum flow rates for all showerheads,kitchen sink faucets and other lavatory faucets. 5b EFFICIENT WATER HEATING 5b: 1.0 Water heating system shall include one of the following: Gas,propane or oil water heater with a minimum EF of 0.74 or Water heater heated by ground source heat pump meeting the requirements of Option 3 c. : • or For R-2 occupancy,a central heat pump water heater with an EF greater than 2.0 that would supply DHW to all the units through a central water loop insulated with R-8 minimum pipe insulation. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the water heater equipment type and the minimum equipment efficiency. 5c EFFICIENT WATER HEATING 5c: 1.5 Water heating system shall include one of the following: Gas,propane or oil water heater with a minimum EF of 0.91 or Solar water heating supplementing a minimum standard water heater. Solar water heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the Solar Rating and Certification Corporation(SRCC)Annual Performance of OG-300 Certified Solar Water Heating Systems. or Electric heat pump water heater with a minimum EF of 2.0 and meeting the standards of NEEA's Northern Climate Specifications for Heat Pump Water Heaters. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the water heater equipment type and the minimum equipment efficiency and,for solar water heating systems,the calculation of the minimum energy savings. RE-36 2015 Washington State Energy Code OPTION DESCRIPTION CREDIT(S) 5d EFFICIENT WATER HEATING 5d: 0.5 1 A drain water heat recovery unit(s)shall be installed,which captures waste water heat from all the showers,and has a minimum efficiency of 40%if installed for equal flow or a minimum efficiency of 52%if installed for unequal flow. Such units shall be rated in accordance with CSA B55.1 and be so labeled. To qualify to claim this credit,the building permit drawings shall include a plumbing diagram that specifies the drain water heat recovery units and the plumbing layout needed to install it and labels or other documentation shall be provided that demonstrates that the unit complies with the standard. 6 RENEWABLE ELECTRIC ENERGY: 0.5 For each 1200 kWh of electrical generation per housing unit provided annually by on-site wind or solar equipment a 0.5 credit shall be allowed,up to 3 credits.Generation shall be calculated as follows: For solar electric systems,the design shall be demonstrated to meet this requirement using the National Renewable Energy Laboratory calculator PVWATTs. Documentation noting solar access shall be included on the plans. For wind generation projects designs shall document annual power generation based on the following factors: The wind turbine power curve;average annual wind speed at the site;frequency distribution of the wind speed at the site and height of the tower. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall show the photovoltaic or wind turbine equipment type,provide documentation of solar and wind access,and include a calculation of the minimum : annual energy power production. a. Projects using this option may not use Option la, I or lc. b. Projects may only include credit from one space heating option,3a,3b,3c or 3d.When a housing unit has two pieces of equipment(i.e.,two furnaces)both must meet the standard to receive the credit. C. Plumbing Fixtures Flow Ratings.Low flow plumbing fixtures(water closets and urinals)and fittings(faucets and showerheads)shall comply with the following requirements: 1. Residential bathroom lavatory sink faucets:Maximum flow rate-3.8 L/min(1.0 gal/min)when tested in accordance with ASME Al 12.18.1/CSA B125.1. 2. Residential kitchen faucets:Maximum flow rate-6.6 L/min(1.75 gal/min)when tested in accordance with ASME Al 12.18.1/CSA B125.1. 3. Residential showerheads:Maximum flow rate-6.6 L/min(1.75 gal/min)when tested in accordance with ASME Al 12.18.1/CSA B 125.1. 2015 Washington State Energy Code RE-37