HomeMy WebLinkAbout18513 59TH AVE NE_BLD1774_2026 COMMERCIAL MECHANICAL
• PERMIT APPLICATION
IN Department of Community&Economic Development
City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone (360)403-3551
THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF CONSTRUCTION DRAWINGS AND ALL
OTHER INFORMATION OUTLINED IN THE MECHANICAL PERMIT SUBMITTAL REQUIREMENTS,IF APPLICABLE.
Type of Permit: New Installation W Replacement Alteration
Project Address: l Sl 3 5�t`N" Ate W G ,c1,121 IN GY1yJ" Parcel#: '31 05- 0721L�b
Project Description: 2W, INN�� Z�wc�Ipb�� tf-�-�� Valuation tZDoO
Owner: Ir k.t Phone#:
0
Address: City: State: Zip:
Email Address:
Contact Person: Phone#:
Address: 2l'?-D "�tt�� A c, �L City: State: Zip: R
Email Address: Nl.Hrww op, &i21 wA , C0—
/IT
Contractor Name: CU%A24 to-" 4 ow$t\/C_ Phone#:
Contractor Address: City: ""�'���'State: Zip:
Email: Contact Person: �(,AIA-
Contractor License Number: L142G 45 O 2z v i Expiration: o le
Please indicate type of number of appliances:
FURNACE CONDENSING UNIT GAS PIPING OUTLET
BOILER HEAT PUMP(multi-split) UNIT HEATER
CHILLER HEAT PUMP(mini-split) PAINT BOOTH
COOLER HEAT PUMP(other) TYPE I HOOD
AC(air cooled) HEAT REJECTION EQUIP TYPE II HOOD
AC(water cooled) VENTILATION SYSTEM AST
AC(evaporator) PACKAGED UNIT �_ UST
AC(VRF) DRYER OTHER
I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-
described property will be iv4c-64rdance with the laws, rules and regulation of the State of Washington. 1 2
Applicants Signature. o Date wd � t*
Applicants Printed Name: w
FOR STAFF USE ONLY
Permit# Accepted By Amount Received Receipt# Date Received
6/16LP Page 1 of 7
CITY OF ARLINGTON
238 N. OLYMPIC AVE -ARLINGTON, WA. 98223
42 PHONE; (360) 403-3551
BUILDING PERMIT
Address:18513 59th Ave NE Permit#:1774
Parcel#:3 1052200103 100 Valuation: 12000.00
OWNER APPLICANT CONTRACTOR
Name:ARLINGTON CITY OF Name:Evergreen State Heat and A/C Name:Evergreen State Heat and A/C
Address: 18204 59TH DRIVE NE Address:2120 Pacific Avenue Address:2120 Pacific Ave
City,State Zip:ARLINGTON,WA 98223 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201
Phone: Phone:425-252-3114 Phone:425-252-3114
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Name:Evergreen State Heat and A/C Name:
Address:2120 Pacific Ave Address:
City,State,Zip:Everett,WA 98201 City,State,Zip:
Phone:425-252-3114 Phone:
LIC#:EVERGSS0220T EXP: 10/10/2019 LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Commercial Mechanical CODE YEAR: 2015
STORIES: CONST.TYPE:
DWELLING UNITS: 0 OCC GROUP:
BUILDINGS: 1 OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED
THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO
WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC 110.
SALES4A NOTICE:Sales tax relating to construc�npd construction materials in the City of Arlington must be reported on your sales tax return form
nd dcd C of Arlington#3101.
l 6 /
Sign Print Name Date Released By Da e
CONDITIONS
Approved as submitted.
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY
CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
12/14/2017 Mechanical Fee(Enter Fixture Fee) $25.00
12/14/2017 Mechanical Permit Base Fee $25.00
12/14/2017 Mechanical Plan Review Fee $250.00
12/14/2017 Processing/Technology Fee $25.00
Total Due: $325.00
Total Payment: $0.00
Balance Due: $325.00
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
CITY OF ARLINGTON
238 N. OLYMPIC AVE-ARLINGTON,WA. 98223
PHONE; (360)403-3551
BUILDING PERMIT permit#:1774
Address:18513 59th Ave NE Valuation:12000.00
Parcel#:3 1052200103 100 CONTRACTOR
OWNER APPLICANT Name:Evergreen State Heat and A/C
Name:ARLINGTON CITY OF Name:Evergreen State Heat and A/C Address:2120 Pacific Ave
Address: 18204 59TH DRIVE NE Address:2120 Pacific Avenue City,State Zip:Everett,WA 98201
City,State Zip:ARLINGTON,WA 98223 City,State Zip:Everett,WA 98201 Phone:425-252-3114
Phone: Phone:425-252-3114
PLUMBING CONTRACTOR
MECHANICAL CONTRACTOR
Name:
Name:Evergreen State Heat and A/C Address:
Address:2120 Pacific Ave City,State,Zip:
City,State,Zip:Everett,WA 98201 phone:
Phone:425-252-3114 EXP:
LIC#:
LIC#:EVERGSS0220T EXP: 10/10/2019
JOB DESCRIPTION
CODE YEAR: 2,015
PERMIT TYPE: Commercial Mechanical CONST.TYPE:
STORIES:
OCC GROUP:
DWELLING UNITS: 0
OCC LOAD:
BUILDINGS: 1
pEgMIT APPROVAL
GTON RELATING TO
1 AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATITHE OABOR CODE OF THE SDOING
A IE OF WASHIN AUTHORI7.F
THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OFY AND ALL FEES PAID.
WORKMENS COMPENSATION INSURANCE AND RCW 18.27•
THIS APPLICATION IS NOT A PERMIT UNTIL SIG N ED BY THE BUILDING OFFICIAL OR HIS/HERN HAS BEEN MADE AND APPROVAL OR
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. our sales tax return form
AL A NOTICE:Sales tax relating to constructionRd construction materials in the City of Arlington must be reported on y
nd ded C of Arlington#3101. Da e
S Released By
Date
Sign a Print Name
CONDITIONS
Approved as submitted.
RS ON PRIVATE PROPERTY ONLY. ANY
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED•THISPERMIRTt COVE MO RQU ES,FT 1'0 BE C.)WILL REQUIRE SEPARATE PERMISSION'
R S
CONSTRUCTION ON THE PUBLIC DOMAIN(CUR
BS, SIDEWALK .
P>LiRMIT FEES Fee Amount
$25.00
Date Description $25.00
12/14/2017 Mechanical Fee(Enter Fixture Fee) $250.00
12/14/2017 Mechanical Permit Base Fee $25.00
12/14/2017 Mechanical Plan Review Fee $325.00
12/14/2017 Processing/Technology Fee Total Due:
$0.00
Total payment:
$325.00
Balance Due:
CALL FOR INSPECTIONS u13LDING(360)403-3417
ing on please leave the t prefer When calling Fos- an in: morning or afternoon
Permit Number,Type of I n s pection be
ing requested,and whetherhen You p y
a
I
�I
Permit Information
Date 12/12/2017
Permit Number 1774
Project Name Arlington Boys and Girls Club
Applicant Name Everegreen State Heat and A/C
Applicant Address 2120 Pacific Avenue
City, State,Zip Everett,WA 98201
Contact Mark Payne
Phone 425-252-3114
Email mark@essmwa.com
Permit Type Commercial Mechanical
Site Address 18513 59th Ave NE
Valuation 12000.00
Status Applied
Permit Issued
Permit Expires
Square Feet 0
Type of Construction/Occupancy Load
Number of Stories 0
Proposed Use Replace Packaged Unit
Assigned To Kristin Foster
-------------------------------
Property
Parcel Address Legal Owner Owner Phone Zoning
31052200103100 18513 59TH AVE NE ARLINGTON CITY OF 431 Airports&Flying Fields
Contractors
Contractor Name Primary Phone Email Contractor Type License License#
Contact
Evergreen State Heat Mark Payne mark@essmwaco MECHANICAL Labor and EVERGSS0220
and A/C 3114 14 . CONTRACTOR Industries
Review
Date Type Descri lion Tar et Date Completed Date Assigned To Status
12/12/2017 lCornmercial Mechanical 12/19I2017 JKevin Olander lin Review
Uploaded Files Upload File
Date File Uploaded B
12/12/2017 4:16:14 PM 11714 Application.pdf Foster, Kristin X
COMMERCIAL MECHANICAL
• PERMIT APPLICATION
�'I N C.'10 Department of Community&Economic Development
City of Arlington • 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551
THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF CONSTRUCTION DRAWINGS AND ALL
OTHER INFORMATION OUTLINED IN THE MECHANICAL PERMIT SUBMITTAL REQUIREMENTS, IF APPLICABLE.
Type of Permit: ❑ New Installation FKI Replacement ❑ Alteration
Project Address: l 6 Sl 3 S�t4 Aw N G A 04
10 6f1k)wt Parcel#: �71 05 to [xj
Project Description: 2 0, I)N 1,T -L4 Z(tnt,00 J e V_,_` l Valuation: l 2, Pa.)
Owner:_6 AA 44 1Ir 18-/L-' Phone#:
0
Address: City: State: Zip:
Email Address:
Contact Person: Phone#:
Address: -2-n-o eA-Lk City: A�5jy ym State: DNA- Zip: I za 1
XrEmailAddress: MAC- (� �55M . t&A, I
Contractor Name: au WL6 ky" 2T4177 t Phone#:
Contractor Address: City: ""���/1``State: Zip:
Email: Contact Person: �l AIPA
Contractor License Number: I ALA 4S O ZZo'r Expiration: F` y le
Please indicate type of number of appliances:
FURNACE CONDENSING UNIT GAS PIPING OUTLET
BOILER HEAT PUMP(multi-split) UNIT HEATER
CHILLER HEAT PUMP(mini-split) PAINT BOOTH
COOLER HEAT PUMP(other) TYPE I HOOD
AC(air cooled) HEAT REJECTION EQUIP TYPE II HOOD
AC(water cooled) VENTILATION SYSTEM AST
AC(evaporator) PACKAGED UNIT �_ UST
AC(VRF) DRYER OTHER
I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-
described property will be i cc dance with the laws, rules and regulation of the State of Washington. �•2
Applicants Signature. Date 1 �
Applicants Printed Name:
- FOR STAFF USE ONLY ecel Ved
Permit# AC to y Amount Received Receipt# Date ecei d
6116LP Page 7 of 7
i
._ ` r- -�
. � , ,
12/14/2017 EVERGREEN STATE SHEET MTL INC
(Search L&I
Washington State Department of
" Labor & Industries
EVERGREEN STATE SHEET MTL INC
Owner or tradesperson 2120 PACIFIC AVE
EVERETT,WA 98201
Principals 425-252-3114
KIMBALL,RUSSELL Dron,PRESIDENT SNOHOMISH County
KIMBALL,PAM,VICE PRESIDENT
(End:09/27/2013)
Doing business as
EVERGREEN STATE SHEET MTL INC
WA UBI No. Business type
601 724 357 Corporation
Governing persons
RUSSELL
KIMBALL
PAM KIMBALL;
License
Verify the contractor's active registration/license/certification(depending on trade)and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
EVERGSS0220T
Effective—expiration
09/30/1998-10110/2019
Bond
RLI Ins Co $12,000.00
Bond account no.
LSM0782384
Received by L&I Effective date
11124/2015 11/25/2015
Expiration date
Until Canceled
Bond history
Insurance
Ohio Cas Ins Co $1,000,000.00
Policy no.
BKS57111316
Received by L&I Effective date
08/04/2017 09/30/2016
Expiration date
09/30/2018
Insurance history
https://secure.Ini.wa.gov/verify/Detaii.aspx?UBI=601724357&LIC=EVERGSS022OT&SAW= 1/2
12/14/2017 EVERGREEN STATE SHEET MTL INC
Savings
No savings accounts during the previous ar period.
Lawsuits against the bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&I Tax debts
No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts
may be recorded by other agencies.
License Violations
No license violations during the previous 6 year period.
Workers' comp
Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums.
This company has multiple workers'comp accounts.
Active accounts
Account no. Account is current.
959,941-00
Doing business as
EVERGREEN STATE SHEETMETAL
Certificate of Workers'Comp Coverage A
Track this contractor A
Account no. Account is current.
959,941-01
Doing business as
EVERGREEN STATE SHEET METAL
Certificate of Workers'Comp Coverage 0
Track this contractor A
Public Works Strikes and Debarments
Verify the contractor is eligible to perform work on public works projects.
Contractor Strikes
No strikes have been issued against this contractor.
Contractors not allowed to bid
No debarments have been issued against this contractor.
Workplace safety and health
No inspections during the previous 6 year period.
0 Washington State Dept.of Labor&Industries.Use of this site is subject to the laws of the state of Washington.
hftps://secure.Ini.wa.gov/verify/Detail.aspx?UBI=601724357&LIC=EVERGSS022OT&SAW= 2/2
to Small Sunline (3-6 Ton Page:3
Package) N543
Single Package R-410A Air Conditioner
Project Name: BOYS&GIRLS CLUB-ARLINGTON,WA REV1 Unit Model#: ZE060H12A1C1AAA1A1
Quantity: 3 Tag#:IN STOCK SEATTLE System: ZE060H12A1ClAAAlAl(3)
AND TIGARD
11 Cooling Performance
Total gross capacity 61.1 MBH
Sensible gross capacity 45.4 MBH
Seasonal Efficiency(at ARI) 14.00 SEER 'ARK,
Efficiency(at ARI) 11.80 EER
Ambient DB temp. 95.0 °F 1
Entering DB temp. 80.0 °F
Entering WB temp. 67.0 °F
Leaving DB temp. 59.0 °F
Leaving WS temp. 57.3 °F ~`
Power input(w/o blower) 4.28 kW
Sound power 82 dB(A)
Refrigerant
Refrigerant type R-410A ' ,+
Gas HeatingPerformance
Entering DB temp. 60 °F
Heating output capacity(Max) 100 MBH
Supply air 2000 CFM 5 Ton
Heating input capacity(Max) 125 MBH
Leaving DB temp. 106.3 °F • York Units are Manufactured at an ISO 9001 Registered Facility and Each
Air temp.rise 46.3 °F Rooftop is Completely Computer-Run Tested Prior to Shipment.
AFUE 80.3 %Stages 1 Unit Features
Supply Air Blower Performance • Single Stage Cooling
• Single Stage Gas Aluminum Steel
Supply air 2000 CFM . 125 MBH Input
Ext. nit pressure IWG
Addl..Unit Losses(Options/Accessories) 0.15 IWG . Unit Cabinet Constructed of Powder Painted Steel,Certified At 1000 Hours
.15
Blower speed 1103 RPM Salt Spray Test(ASTM B-117 Standards)
Duct location Bottom • Either Supply and/or Return can be Field Converted from Vertical to
Motor rating 1.00 HP Horizontal Configuration without Cutting Panels.
Actual required BHP 1.02 HP . Full Perimeter Base Rails with Built in Rigging Capabilities
Power input 0.95 kW . S Compressor
Com
Elevation 0 ft. p
Drive type DIRECT • Dry Bulb Economizer and Hood(No Barometric Relief Damper)with
Speed tap 5 Economizer Fault Detection&Diagnostic(Meets ASHRAE 90.1-2013,IECC
Electrical Data 2015,California Title 24,AMCA 511)
Power supply 230-1-60 • 1 HP Direct Drive Blower
Unit min circuit ampacity 42.5 Amps • Solid Core Liquid Line Filter Driers
Unit max over-current protection 60 Amps • Unit Ships with 1"Throwaway Filters
Dimensions&Weight • Replacement Filters:2-(15"x 20"x 1"or 2")and 1 -(14"x 25"x 1"or 2").
Hgt 33 in. Len 83 in. Wth 45 in. Unit accepts 1"or 2"wide filters.
Wei ht w c ory installed options 694 lbs. • Single Point Power Connection
Clearances • Short Circuit Current:5kA RMS Symmetrical
Right 24 in. Front 32 in. Back 36 in. Through-the-Curb and Through-The-Base Utility Connections
Top 72 in. Bottom 0 in. Left 36 in. Microchannel All Aluminum Condenser Coil,Copper tube/Aluminum fin
Evaporator Coil
Note: Please refer to the tech guide for listed maximum static pressures Galvanized Steel Drain Pan
Standard Access Doors
109"Opy Standard Unit Controller: Simplicity Control Board
• An Integrated Low-Ambient Control,Anti-Short Cycle Protection,Lead-Lag,
Fan On and Fan off Delays,Low Voltage Protection,On Board Diagnostic
and Fault Code Display.Allows all units to operate in the cooling made down
to 0°F outdoor ambient without additional components or intervention.
• Safety Monitoring-Monitors the High and Low-Pressure Switches,the
Freezestats,the Gas Valve,if Applicable,and the Temperature Limit Switch
CITY OF ARLINGTON
on Gas and Electric Heat Units.The Unit Control Board pill Alarm on Ignition
BUILDING DEPARTMENT
Failures,Safe Lockouts and Repeated Limit Switch Trips.
APP OVED BAS Controller
• Simplicity SE Controller including Discharge Air,Return Air,and Outdoor Air
DATE Z Temperature Sensors
Warranty
NO CHANGER AUTHORIZED . One(1)Year Limited Warranty on the Complete Unit
UNLESS APPROVED ZEDTHM . Five(5)Year Warranty-Compressors and Electric Heater Elements
' Ten(10)Year Warranty-Aluminized Heat Exchanger
BUILDING INSPECTOR
Unitary Sales Tool 0.5.9.0 Information is subject to change without notice.Check local codes. Printed 11/22/2017
jI•J
"iJ2`Y0FK
Small Sunline (3-6 I Page:4
Package) N543
Single Package R-410A Air Conditioner
Project Name: BOYS&GIRLS CLUB-ARLINGTON,WA REV1 Unit Model#: ZE06OH12A1ClAAAlAl
Quantity: 3 Tag#:IN STOCK SEATTLE System: ZE060H12AIClAAAlAl (3)
AND TIGARD
Factory Installed Options
ZE060HUA1C1AAA1A1
York Small Sunline Single Packaged R-410A Air
Product Category: ZE Conditioner
11.8 EER/14.0 SEER
Nominal Cooling Capacity: 060 5 Ton
Single Stage Cooling
Heat Type and Nominal Heat Capacity: H12 Single Stage Gas Aluminum Steel125 MBH Input
Blower Option: A 1 HP Direct Drive Blower
Direct Drive
Voltage: 'I 208/230-1-60
Dry Bulb Economizer and Hood(No Barometric Relief
Economizer/Damper: C Damper)with Economizer Fault Detection&Diagnostic
(Meets ASHRAE 90.1-2013, IECC 2015, California Title
24,AM CA 511)
Service Options: 1
Sensor Options: A
Controls: A Simplicity®SE Controller including Discharge Air, Return
Air, and Outdoor Air Temperature Sensors.
Refrigeration: A
Microchannel All Aluminum Condenser Coil,Copper
tube/Aluminum fin Evaporator Coil
Additional Options: 1 1"Throwaway Filters
Galvanized Steel Drain Pan
Cabinet Options: A Standard Access Doors
Product Generation: 1
Field Installed Accessories
(D 1 RD0410-Barometric Relief
Damper with Hood Kit(Downflow
Unit or Duct Mounted) (6.0 Ibs)
Unitary Sales Tool 0.5.9.0 Information is subject to change without notice.Check local codes. Printed 11/22/2017
t
M Bon
y0JK Small Sunline (3-6 Ton Package) N543 Page:5
Single Package R-41OA Air Conditioner
Project Name: BOYS&GIRLS CLUB-ARLINGTON,WA REV1 Unit Model#: ZEO6OH12A1C1AAA1A1
Quantity: 3 Tag#:IN STOCK SEATTLE AND TIGARD System: ZEOGOH12AIClAAAlAl(3)
Consolidated Drawing
NOTES: V OPERATING
1. FOR OUTDOOR USE ONLY. IT WEIGHT OF GRAVITY 4 POINT CORNER LOADS LBS BASE UNIT
2.WEIGHTS SHOWN ARE FOR COOLING ONLY UNITS. TONNAGE WEIGHT(LBS LOCATION BASE UNIT ( ) ( )
3. MIN. CLEARANCES TO BE: (BASE Lim) K Y A 8 C D
RIGHT SIDE:24 669,6 3 ZE 470 213 34.5 876 3 18,25[463,6 ILL SB 80 76 117 53 162 73 LE SIDE: 24 609,6 LESS
ECOHB2ER
36 914,4 ONJM 4 2E 598 271 36 914,1 18.50 469,91 139 1631 108 49 154(701 198 9e
FRONT: 24 605,6 ICWIWTLNINEC6/[LEMCIZTERRlCiHEAT))HEAT) 5 Zf 632 m 37.5 9S2,S 18.2[4623 139 63 117 531 171 78 204 93
REAR: 12 30432 .8 LESS EECOilONIng) 3 ZF 468 212 33 1838.2) 11.25 463,E 114 52 76 35 ILL 50 167 76
36 934,4 KITH ECOIVd4IZEA OR FIXED 4 ZF 541 245 31.50 800 1 18.56 469,9 138 63 85 39 122 SS 196 89
AIRINDTONI2ED DAMPER)
TOP: 72 1828,8] S ZF 569 1258 1 37(939.81 15 13811 105 48 86 39 170 f771 10$1941
BOTTOM: 0[01 31.62 6 ZF 640 IMI 37[M.01 15 13811118 S+ 96 44 192 87 234 106
4. FOR SMALLER SERVICEIC AND OPERATIONAL IN CLEARANCES [803,3] 3 ZR 575 Z61 40 3016 20 SOS 132 60 125 57 1S5 70 164 74
CONTACT YOUR S DESIGNED ENGINEERING DEPARTMENT. 6.12
S.ROOF CURLOW DUCTS DESIGNED TO BE ATTACHED TO ACCESSORY [155,51 4 2A 585 265 40 1016 20[Seal 134 61 127 SB 158 72 167 76 ROOF CURE ONLY, IF UNIT IS MOUNTED SIDE SUPPLY,IT 7.25 18.26
IS 6ECOKMEMDED THAT THE DUCTS ARE SUPPORTED BY [184,01 [463,73
5 590 268 48 1016 20 508 135 61 128 58 159 72 168 76
CROSS BRACES,AS DONE ON ACCESSORY ROOF CURBS. 3 IN 1 610(I771 38.3 1972,81 18.75 1476,31 136 161 119(S41 16$1751 190 1861
6.SIDE DUCT FLANGES ARE 0.875"(22,21 HIGH. 1.88 27.54
BOTTOM DUCTS DO NOT HAVE FLANGES. 145,81 [699,61 4 $111616 Ill 1.2 910,3 18.4 467.4 135 61 117 S3 169 77 195 198
7.N�1MH1STNNEFGA TrvONSTRAOCHEIGHT SHALL BE 1.5 TIMES 1 5 20(281 38.6 960,1 18 457,2 132 60 117 53 174 79 197 891REAR 1 ( ] ) ( )8.OINEHSIQVS IN ARE IN MILLIMETERS OR KILOGRAMS. 3 75 261 39 998 6 20 508 135 6l12155151 69 168 769.GPiIONAt COIL UA� GAS HEAT,FCONOMI2ER HOOD, 5.8985 265 39 99B 6 20 Se8 137 62 124 56 154 N 171 76DISCONNECT SWITCH,CONVENIENCE OUTLET,ANDOUTLET/INLET HOOD SHOWN. 5.51 [14940 266 39 1990.61 28 588 130 63 125 S7 155[701. 172 78
®EXCEPT XN& XP(HEAT PUMP)UNITS. [140,0] L � $
—► DIRECTION OF AIRFLOW jy
CENTER OF GRAVITY 13U 31 [ (292 11
POWER WIRING BOTTOM ENTRY ///
[1 106 62.00(58,8] T �(Na 9 RIGHT 0°/1 / t _ (16 Z1(292 1]
4. ] �— RETURN. II.SB 19.08
8.23 Y SUPPLY B/A 1292 1)14841,61
D L 6.48 C 6'50 4.58 116,3
(2$1,e1 [164,7] 17.50 7,62
CONTROL WIRING BOTTOM ENTRY 32.09 GAS SUPPLY BOTTOM ENTRY01.50[38,11 K.O. (444,51 1193,61
00.80 122,21 [815,2] (0.50 112.71 BPT AT GAS VALVE 17.50 31.62
ECON0412ER HOCO 01.97 K.a % VENT AIR OUTLET HOOD [444,51 [803,21
(OPTIONAL) (S0, COMBUSTION AIR INLET HOOD REAR(PARTIAL VIEW)
DISCONNECT SWI/CH (RAIN HOOD NOT$H"IN THIS VIEW)
COVER(OPTIONAL) yypp
FILTER yy �CFSS
I11�' ACCESS A��ESS v CONVENERNCE OUTTLE Cr` g�9pHEp t
27.35 ) [865�1
(694.71 0.88 K.O. AACCCCff
�22'21
3.78 4.38 6.9d
18.58 I— (96,01 [111,1] [176,2] 44.88
[471,91 0.75(19,1 4112,3 31,89 —GAS SUPPLY ENTRY [1139,8] (OIL GUARD
PVC FM 19.67 [112,31 [810,a] 01.63(41,41
Cow.DRAIN [499,71 2.55 $2.19 RIGHT VIEW (OPTIONAL)
LEFT VIE (64,71 (2081,6] FRONT VIEW
Unitary Sales Tool v1.5.9.0 Information is subject to change without nolice.Check local codes, Printed 1122/2017
WYORKSmall Sunline (3-6 Ton Page:6
Package) N543
Single Package R-410A Air Conditioner
Project Name: BOYS&GIRLS CLUB-ARLINGTON,WA REV1 Unit Model#: ZE060H12AIClAAAlAl
Quantity: 3 Tag#:IN STOCK SEATTLE System: ZE060H12A1ClAAAlAl (3)
AND TIGARD
Component Location
Component Location
Gas/Electric
Power Venter Motor With
2T Gauge eat Excha Post Pwgo Cycle
Steel Tubular Heal Exchanger
14gh Efficiency
HACR Compressor
Economizer Bto ker t
Hood
Highly Efficient
Enhanced Copper
Tube/Enhanced
a Aluminum Fin
Knockout 01
For Sido Micro-Channel
Power Entry c,_ ® Aluminum
TubelAl nminum
Slide-In Fin Condenser
Economizer
Smoke S
Detector i cf
Q Full Perimeter Baserails
e With Forklift Slots And
3I PVC Femolo nakaut Fa side Lifting Holes
Condensate Drain - Gas Supply En
GFCI S7mpgcily®Life*'�. PP Y kY
Convenience Outlet Or Simplicity BE
Knockout Belt Oriva Or Control Board
For Side Direct Drive
Control Entry Blower
Unitary Sales Tool 0.5.9.0 Information is subject to change without notice.Check local codes. Printed 11/22/2017
ov'YORK
Small Sunline (3-6 Ton Page:7
Package) N543
Single Package R-410A Air Conditioner
Project Name: BOYS&GIRLS CLUB-ARLINGTON,WA REV1 Unit Model#: ZE060H12A1ClAAA1A1
Quantity: 3 Tag#:IN STOCK SEATTLE System: ZE060H12AIClAAAlAl (3)
AND TIGARD
Typical Application
ROOFJACK
saw j INSTALLATION
r
I < <a
I I
I 1
ROOFCURB
INSTALLATION
a
t
I I I I
I I I I
SLAB ON GROUND
INSTALLATION
FIELD-SUPPLIED
DISCONNECT SWITCH
t I h;
zt�"P?T •i�I' �1��t I I � i'i � �
DRIP LEG
=�. `t�� I ✓ a hF' ' ." MANUAL
•I yyw... r l 4;::. emu.�/,5.�•'.•:',
C�tx I �: •3 I I :"'''••• _ GAS SHUT-OFF
VALVE
t._ I
1 ROOF CURB
j CONDENSATE
TRAP y` TO GAS SUPPLY LINE
jYN•cx:
� SUPPLY AIR
DUCT
TO CONTROL WIRING rr:
POWER TO INDOOR / RETURN AIR
SUPPLY THERMOSTAT +f'l DUCT
Unitary Sales Tool 0.5.9.0 Information is subject to change without notice.Check local codes. Printed 11/22/2017
� �L
18513 59th Ave NE - Arlington_�A- MapQuest Page 1 of 2
1
18513 59th Ave NE
Arlington I WA 98223-7846
r
•
Book a hotel tonight and Car trouble mid-trip?
save With some great deals! MapQuest Roadside
(1-877-577-5766)
Assistance is here:
(1-888-461-3625)
https://www.mapquest.com/us/wa/arlington/98223-7846/18513-59th-ave-ne-48.164708,... 12/12/2017
_'
I
01
TEXAS •fie �� , , `4
LLAS, y 1,,11,,1 •,f1Y11`,
T . ►, 1;cm 1IR �i. A11; CHAT
FNS lei. db-1989 GRS '?"''' 1kv UlfIt R�. h � "�t;�1Nf
CEHIRAI_ FURNACE ' 9f A ,i;}1�, 'F „ l A1. rT ;11h's ►� ..
IN W-Whi
t `MOM AIR FURIdAM / MU NI-' �` ���'' .���' IiJDEL1:
`l;1 T ZGUIPPED FOR" NATURAL
' t� 7�/.'�ti• � r ' �y , �j ' 1 vF .•► i �• ;'sya�•.'�•'•�._. • ? APP1t0'/f.l ,i
�. is�d1.'��6�V.If 1�7/4$� �' 1'` /� `*,. �'-...-j�G'.•�Cfi.4a1 Ft��l.•=,' '! �'=,•t' •�
#. _D 1'54 %0,4IF EGcI.;E ��' '.'• +?n`� _�i
fir•
.0� /BTUH ` '1 ^a 4`1'� 'iWOL�Ii�t ,�,
} �' `AL1r1ENTAii►7j!'.EN' CA1. 1111VIME 9{1110
4,11FOLD PRk �s .<<.. 'i 37' It!l. W. C. , J �` zYUD� og '•0 .�5t)Q ^
�Y •GiNs- SUPPLY PF I0.- r TN W. C.
> �x ALT
�� t• �, :1 ' iI`':::' N, -i,T !rR.RECQ1111AMdrE' PAR 1,F rARRICA;1"
r:GAS SUPPLY RPUS. 1<':a THE-{ _., _ l- �'•1 DE TEMP. 20-50 { .ill f�l.l t
� .JPP4SE OF iriPll.1 h•7JUS t,t� . r im. W. C. ,E � ��,, ,,, a• . TO
t
I OU11ET AIR T�EP1P. :
R:�SE 20-5A. WITF � Hi? FOR 1'�� 4E`;�kIF.r rOv IlU REF�FtOItlI55EA1t
� '?N. 5TAT1C PRESS. =1. r �' ► ,, ';t 1� SEE :r 1�5IME 7i LSS; '
1 7. COOI.IAjEy D <A / �'F� b r a_ESAIJT .P'.=.C.
j � FACTORY 'CHARGED: '7 L 'F 0 {�':S �s a<�.-A , Tiy�' q {E'v 'tl" ;zC' u7Uz : I -
! a E g rIR !�( �. �}_ ..W a M6�
„ R?LSSY 3Q0 PSI-HIGH; 1 �PSi -!_ 1W �t ire, .r '�A1+tT'
art jjOL ,,
,E;LF-CT91CAIL RATING � ,N���;���tNaRlja =bTF1'�.':1E 0.7 s�L► A n..�l
34/2+ T [� 60 HZ.1. PH. NOT .TO B ' PERATED
MORE .TRAM 53 ( TS. ,r ,cif? 7i `''"'"r t�. `:11�I5 LE C.LRCUIT r,�\� ,
42. 0 ,t t3LE (MDL) b.+) t?,1. a
CKT: BKR. bu AI�Pg' J� �ANt;E nll MO'TEUE? 1•�•
6Y� MOTOR' RLto GV PH FI-A LRA �
Wr HP Pii, FLA LRA ` f:=i'f>> 1ctlk a'. b
_� t��,�.Sl]R •: �7. i; • _ _ 1 '� - -°�� '' �:.' s=�.':cl�'Z� a• .Y.:i.�3/�!• [ { � �� 1
�FF'BLU'' ER ''�s .��� 0
DENSER FAN 1,{'i: L 2. i x :« ;Q1IEFGAC D, �t,, _ 1 Q. 7«
(. nh $TION Alf, SLO14ER -1 0. 75) • i/ u;DSO J -
208/230 V ALL UNI
LAY; _,j`.4 XT'ERIEUR SELtF't' !... �i-
i�'s3El NO. & SERIAL K.'' IR._GRGERIHG,f:FPA1R �. 1 1*:-4,?jBiAPITE !;[N, 401,5' LAQ,UELLE
jx 'O=,1TD-3OR INSTALLATkP,!' fc=,gLY ... , AA'fiE14 PELIT FQ'l,,y7'T�0NNER: N
f� AntsNCES TO CL11161lSTIBIE GC1i51F CTIGN (IN_) `�. , '� �� ; : C: Yri� `.,y
- t q ,l: 1 + �, cF(laF Ar1T �,,A,, a� _
36: REAR: 12, FtIG11 a10F 16, TOP: t• T ,;_
> �r L -60 r A C CI.IAUFF tl
IT�.I(f+TEO �, .,,: + t� � � 1~�� 1 ICNAit?�r:c, ' S
t aT tL•ATION ON U00L1' 1rOGt�1,0G O A CLASS A ' ' l� Sk 01- -6P° 99.E r f
�,Ufi CLASS C FOGf CGi1tR111G,3A, L IiITH ' , :EVENTS 1�[N POUFS( 1NSTriLL TAN (COlfitl�lflf: 3c-��
o+ :.PAREIL Ot:UANT) CO(E i►AUC}t CO'lf� ORO�j
FC,� O�g�l'.01A{ tI`GN.N,�I congUITI FL NIT`E � ►'' ; �R€ '.�.AO. .OESSUS HON OB$TRUE. `i !
'sOTTOtt�'01:;"f OE.>t •� J 'C�iLLr�TXON SUR'IJN PLANCHER CQhf��15F1' L�j
!F(^ r CaCTRC� L TION I) ' IR HORrZONI'AL ET :1t�1 ;# I
5 OR GN Ati �: : lCHER N OMRUST12; �-
r� rEL 8., 1,94LASS C` OF', Fi ITH 90TTOn [1 . +�, 4E A�,LC 1;yiRl,IJ} =,!'aa�l
Ilt„97ALCEO qli SPELTt�!1r;L s� PART NO. R11F16 r� ^�XR DE5Cr�1 73 TE31
,S dFib%&� 1' . s+p�,l�r 1'NiTkll,(AZ , Suk (lN1PL F CAl1HUSt;�I: '
ERVX(:� Cp; Ell � IN ;. "'�'- 1:I1�11 Abl bl'J) kIk O�ac.4r� 1E aIJn1Yt! ALA 3
jON f . ,.RhElb?�! QU
1 R tiRTlb'i OR tlOR NFuhnATt �. ;.Tl �t DF i '
s A).
L'$1.:9E INSTALLE co CE WTH hFR t �:JRt?^'" �' i F ti , �;q, 1 �
L 0001�ei, 'tl °, 'CE OF LOCAL
I Z2V.141 *
' -4 �.�•. ' :'L .!• •_._mil: •
• 1�1:`•'1` i:` "�-.-r._I .�._ � wn; f� I� ...._..r•AtlE�f 5,.;1
`•f' �. s ��:�,�,(1 ' �'' RONTO, ONTARIOR. 1 i
�. U 1A F RNACF. {l I fH i Ja?L[NC
' I{FPf,O"FOR,NATURAL CAS ` t
1
Model No. GCS16-511-75 GCS10-511-125 GCS16-651-75 r (3CS16-661-1p
GCS16.513-75 GCS18-513.125 GCS16-653-75 _6C$16-653.125
Heating capacity input 18tu_hl -- Natural Gas /6,000 125,000 15,000 125,000
Heating capacity output (Btuh) Natural Gas _ 58,000 95,0W 58,000 95,000
Heating capacittinput (Btuh) - 'LPG 67,5W 112,600 67,600 _ 112,500
Heating caeacity output (Stuh) - "'LPG 52,000 85,000 62,000 S5 000
Natural Gas 78,4% 78.3% 78.4% 78.3%
1A f.U.E "LPG _79.9% �78.6% -'_ ___.. 7B.4% 70.59L -`
California Seasonal Efficiency Natural Gas 72.7% 75.0% __ 72.7% 75.0% _
""LPG 73.7% 75.0% 72.3% 75.0%
*ARI Standard 210 SRN Ibelsl 8.2 8.2
'ARI city Wtuh) _ 46,500 58,EW
Standard Total unit watts 4890 6570
210/240 SEER (Btuh/Watts) � _ � �.. _10.35 10.00 �~--
Ratings EER (Btuh/Waits) 9.5 8.90
Refrigerant(R-27.) char e 6 lbs.0 oz. 7 lbs. 0 oz.
Evaporator Blower whool nominal diameter x width (in.) 11-1/2 x 9 -� 11-1/2 x 9
Blower Motor horse iowor 3/4 3/4
Not faco area (sq. ft.1 6.3 6.2 _____ _
Evaporator Tube diem. lint& nurnbar of rows 3/8 - 2 3/8 - 2 T _
Coil Fins par Inch -�� 16� 15
Net face Outer coil 14.3 14.3
Condenser area_lsq. ft.) Inner coil _ 5.9 13.7
Coil Tube diem. (in.)& number of rows 3/8- 1.4 3/8 -2 _
Fins par inch 20 20
Diameter tin.)& number of blades 24 4 24-_4
Condenser Air volume(cfrn) _ 3880 3770
Fan Motor horsepower 1/4_- 1/4
Motor watts 340 360
Gas Supply Connection t t(in.) -- Natural& "LPG 1/2 1/2
Recommended Gas Natural 7 7
Sup Iv Pressure(wc. In.) "'LPG - 11 11
Condensate drain slzo mpptt (in.) 4 /4
Number and size of filters(in.) _ (1).20 x 25 x_1 oil urethane) _.
Not weight of basic unit ilbs.) _^ 65D 590 5.9f1 560
Shp�in�waA�f of basic unit(lbs.) 1 ack��kego - 660 710 ___� J 620
Electrical characteristics(50 hz) _208/230v - 60 hz - 1 or 3 phase or 460v - 60 hz --- 3 phase _
""Optional LPG convorsion kit LB-62090DB LB-62090DD LET'2090DI3 LB-62090DD
Optional Condenser Coil Guards _ LB-82199CC
Optional Outdoor Air Dampers (Manuel) - iNet Weight) OAD16-65(12 lbs.)
filter media size(in.) -_� _.�m 8 x 17 x 1
Optional Roof Curb Power End Kit (conduit size) _ �181-170(1/2") _
Optional Roof Mountieg Framo - (Not Weight) _ RMF16 41 (75 Ibs.) or RMF16.65( lbs.)
Optional Model 3 posttlor (Net _ REMD16-65 66 lbs-1_
Economizer Dampers No. Moduloti (Net Weight) _ RFMDI61VII-65 166 Ibs.l
with Number and size Indoor •(/1 20 x 25 x 1
Gravity Exhaust of filters (in.) Outdoor 11) 18 x 25 x 1 (alu inum(nosh)
Optional Model 13 position (Not Weight) EMDH16-6
Horizontal No. [Modulating(Not Weight) EMDHI6M-65 -10 bs.)
Economizer Number and size Indoor _ (1) 16 x 25 x 1_& (1) 14 x 25 x 1 (fiberglass)
Dampers of filters (in.) Outdoor (1)8 x 28 x 1(aluminum mesh)
Optional Gravity Exhaust Dampers - (Net Weight) GEDH16 65(4 lbs.) Use with EMDH16
Optional Ceiling�w Supply and Step down RTD9.65 (67 lbs.) Lis
Return Air Diffusers Flush FD9.65(37 lbs.)
(Net Weight) Transition SRT16.65(20 Ibs.l
_ Electro-Mechanical Thann_ostat Controls _
W973 Controls _
Optional Controls Selection --w W7400 Controls
Pru-stdi Thermostat Cuntruls
T7300 Thermostat Controls
Optional Down-flo Units Commercial Controls Box _ _ _23H14
tttCommercial Controls Platform Furnished and Factory Installled
tAnnual Fuel Utilization Efficiency based on DOE test procedures and FTC labeling regulations.
*Sound Rating Number in accordance with ARI Standard 270.
'Rated In accordance with ARI Stendard 210/240 and DOE;95°F outdoor air temperature and 60°F db/67°F wb entering evaporator air.
"For LPG units a field changeovar kit is required and must be ordered extra.
t1tFurnlshed as standard.Consists of:factory installed controls system and economizer wiring harness.
4Indoor filter is not furnished With'oconomizer. REMD16 utilizes existing filter furnished with GC516 unit,
-10-
2015 Washington State "argy Code Compliance Forms for Commercial, R2 ",R3 over 3 stories and all R1
, Mechanical Summary MECH-SUM
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017
Project Information Project Title: Boys&Girls Club-Arlington Date 4/3/2017
Applicant Information. Provide contact information for individual who can respond to For Building Dept, Use
inquiries about compliance form information provided.
Company Name: Evergreen State Heat&A/C
Company Address: 2120 Pacific Ave,Everett,WA 98201
Applicant Name: Mark Payne
Applicant Phone: 425-252-3114
Project Description ❑ New Building ❑ Building Addition ❑ Tenant Improvement ❑� System Retrofit ❑ No System Changes
Briefly describe mechanical systems in Replacing like for like with same capacity,power requirements and gas heat as old unit. old unit provided
the text box provided sufficent heating and cooling.Unit is a single phase 5 ton RTU.
❑ Total Bldg Performance(TBP)
This path includes all mandatory
provisions perC401.2 Option 2.
MECH-SUM,MECH-CHK,and C407
Energy Analysis forms required.
❑ Load calculation summary 0 MECH-LOAD-CALC Form
Design Load Calculations Provide design load calculations for all mechanical systems and equipment serving the building heating,cooling or
ventilating needs.If a load calculation summary is provided with the permit documents that includes all applicable
compliance information then the MECH-LOAD-CALC form is not required.
❑✓ Mechanical Plans ❑ MECH-EQ Forms(TBD)
Mechanical Schedules Indicate location of equipment compliance information.If provided on plans then MECH-EQ forms are not required,
however,include on plans all applicable compliance information listed in MECH-EQ tables.
❑ DOAS is required per C403.6 effective July 1,2017(office,retail,education,library and fire station occupancies)
All occupied,conditioned areas shall be served by a DOAS that delivers required ventilation air in a manner that does
not require space conditioning fan operation. Space conditioning fans cycled off when no heating or cooling is required.
Dedicated Outdoor Air ❑ Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS(C403.6,Exception 1)
System Requirements and ❑ ventilation and space conditioning provided by a HEVAV system per C403.7 in lieu of DOAS(C403.6,Exception
High Efficiency VAV ❑ DOAS included in project,although not required(occupancy not office,retail,education,library or fire station)
Alternate ❑ DOAS related allowances included in project:
❑ Prescriptive vertical fenestration maximum area allowance increased to 40%per C402.4.1.4 with 100%of
conditioned floor area in building served by DOAS.
❑ Exception to air economizer per C403.3 Exception 1,include MECH-ECONO form.
❑✓ Project includes HVAC air distribution systems that provide heating and/or cooling
If yes,provide a MECH-FANSYS-SUM form.
Fan Power ❑ For one or more systems,the total fan motor nameplate hp of all fans in HVAC system exceeds 5hp.
If yes,provide a seperate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold.
Refer to Section C403.2.11 and MECH-FANSYS-DOC for requirements and exceptions.
❑HVAC Hydronic Systems Hydronic chilled water ❑ Water-loop heat pump ❑ No hydronic systems
❑ Hydronic heating water ❑ Geothermal
❑ C406.2 More efficient HVAC equipment and fan systems
Requires 90%of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9)or air-to-water heat
pumps and heat recovery chillers.All equipment listed in tables C403.2.3(1)-(7)must be 15%more efficient than
minimum requirements.All stand alone supply,return,and exhaust fans over 1hp must have FEQ z 71 and must be
C406 Additional Efficiency selected within 10%of maximum total or static pressure.
❑ C406.6 Dedicated outdoor air system(DOAS)
Options-Mechanical Requires 90%of conditioned floor area to be served by a DOAS per C403 6 that delivers required ventilation air in a
manner that does not require space conditioning fan operation.
❑ C406.7 Reduced energy in service water heating
Requires 90%of floor area be in occupancy types listed in C406.7.I and that 60%of annual hot water energy use be
provided by heat pump,waste heat recovery or solar water-heating systems.
.�
.' �
I
I
2015 Washington Statf rgy Code Compliance Forms for Commercial, R2 R3 over 3 stories and all R1
Mechanical Summary, • •
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017
Equipment Type(s)
❑ Hot water heating tank(s) ❑ Instantaneous ❑ No service water systems
Service Water Heating El Dedicated boiler ❑ Heat exchange from space heat boiler or
Systems central hot water/steam
Distribution Type(s)
❑ Circulation System ❑ On-demand
Commissioning Commissioning is required for:
❑ Mechanical systems per C408.2 ❑Service water heating systems per C408.4
If required,commissioning shall be performed for all applicable systems regardless of individual equipment capacity.
Exceptions to commissioning requirements:
O Total output capacity of all mechanical space conditioning systems in the building do not exceed 240,000 Btu/h
cooling or 300.000 Btu/h heating.Mechanical systems commissioning not required.
❑ Capacity of largest service water heating system in building does not exceed 200,000 Btu/h.Service water heating
systems commissioning not required.
Low Energy and Semi-Heated Spaces (Note 6 and 7)
Peak Space
Heating Cooling Conditioning
Space Area Served, Capacity,Btu/h Capacity,Btu/h Capacity, Compliance
Type Location in Plan(s) Space(s)Served square feet (Note 4) (Note 5) Btulh-sf Check Notes
Note 4-Provide total installed heating output capacity of systems serving Low Energy or Semi-Heated space(s)in btuh.
Note 5-Provide total installed cooling capacity of system serving Low Energy space(s)in Btu/h.Not allowed for semi-heated spaces.Enter 0 if no cooling.
Note 6-Refer to Section C402 I Low Energy Building.Intalled peak space conditioning capacity,heating or cooling,may not exceed 3.4 Btu/h"sf.
Note 7-Refer to Section C402 1 1 1 and Semi-Heated Space definition in Chapter 2. Total heating output capacity may not exceed 8 Btu/h sf. Only systems without
electric resistance heating and no cooling are eligible for the wall insulation exception under semi-heated.
2015 Washington State Energv bode Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017
Project Title: Boys&Girls Club-Arlington Date 4/3/2017
For Building Dept. Use
HVAC Air Distribution System Schedule
List all HVAC systems that have the capability to provide heating and/or cooling to the spaces they serve.
Fan Power
System or System Total Calculation
Primary Supply Speed Control Description Nameplate HP Required
Fan ID (Note 1) (Note 2) (Note 3) (Note 4)
Unit 1 CV Supply fan included in equipment cut sheet 1 No
Note 1-Constant Volume(CV), Variable Air Volume(VAV),or Hospital/Lab CV system that qualifies for VAV budget per C403.2.11.1 Exception 1.
Single zone VA systems shall comply as CV.
Note 2-Describe system type and list all fans(or groups of fans)associated with the delivery and removal of conditioned air by the system.Include
all supply,return/relief,exhaust and exhaust hoods(>1 hp),make-up air,dedicated outside air(DOHS),booster fans,and series fan-powered
terminals VAV parallel fan-powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak
conditions.
Note 3-Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air by the system
Note 4-This form automatically identifies whether a MECH-FANSYS form is required to demonstrate compliance with the fan power allowance(Yes),
or this information is not required because the system has a combined total nameplate motor hp that is 5 hp or less(No)
MECH-FANSYS Forms
A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 5 hp. Select(Add Fan
System Form)to generate an additional form. Added forms can be deleted with button in cell E32 of the added form.
r I � �� `b
i� .
2015 Washington State Energy"ode Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1
St ower Allowance MECH-FANSYS
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017
Project Title: Boys&Girls Club-Arlington Date 4/3/2017
A separate MECH-FANSYS form must be completed for every HVAC system that exceeds the 5 hp threshold. For Building Dept. Use
Fan System ID
System Supply Fan Constant Volume(CV), Variable Air
y pp y CV Volume(VAV),or Hospital/Lab CV
Speed Control system that qualifies for VA budget per
C403.211.1,Exception 1
Compliance is based upon either the fan motor nameplate horse power
Compliance Option Nameplate HP (Option 1), the fan brake horsepower(Option 2), or C403.7 high efficieny
VA fan brake horsepower(10%less than Option 2). The bhp calculation
provides adjustments for special equipment per Table C403.2.11.1(2).
In Fan Equipment Schedule below,provide maximum design supply airflow
rate(CFM)of all supply fans serving the conditioned space in Fan
Fan System Supply Equipment Schedule below. Fan System CFM Total is the supply airflow of
y pp y 2000 the central air handler at peak design conditions.Additional volumetric air
,
CFM Total flow provided at zone fan terminals,booster fans,or through induction is
not included in the supply CFM total.However, the fan power of this
equipment is included in the HP and BHP calculations.Fan System
Supply CFM Total is automatically calculated by the form.
Fan Equipment Schedule
Total CFM Total Nameplate Total BHP
Fan ID and Location Fan Type Quantity of Fan Type (Note 1) HP(Note 2) (Note 3)
Unit Supply 1000 2,000 1 1
1 i i i
Note 1-Total CFM is the maximum CFM of the listed fan(s)when Total Proposed: 1.0 1.0
operating at peak design operating conditions
Note 2-Total namplate hp of the listed fan(s). Total Allowance: 2.2 1.9
Note 3-Total brake horsepower(bhp)of the listed fan(s)at peak
design operating conditions. Not required
if Nameplate HP compliance option chosen. Compliance Message:F
COMPLIES
Brake Horsepower Allowance Adjustments
Assigned Pressure CalculatedAdjustment,
Device Type Description and Location CFM thorough this Drop, PD in w.c. Pressure Drop, A in bhp
device(CFMD) (Note 6) PD in W.C. (Note 8)
(Note 7)
Note 4-Bhp allowance for energy recovery devices and run around coil loops includes both air Total Adjustment(bhp): 0.00
streams,so the CFMD is the sum of the supply CFM and exhaust CFM if both go through
the device.
Note 5-Energy recovery effectiveness is defined as change in the enthappy of the outdoor air supply
divided by the enthaply difference between the outdoor air and return air at design conditions.
Note 6-Assigned pressure drop(PD)adjustment per Table C403.2.11 1(2).
Note 7-Pressure drop(PD)adjustment shall be calculated per the applicable method
defined in Table C403 2 11.1(2)based on specific system conditions.
Note 8-A=PD'CFMD14131 where A is the allowed system brake horse power
adjustment, PD is pressure drop allowance,and CFMD is the cfm through the device.
2015 Washington State Energy rode Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1
General Instructions:
A. Include all fans directly associated with the delivery and removal of conditioned air to the zones served by the system.Enter CFM and brake
horsepower(bhp)of each fan at peak design conditions and the nameplate horsepower(hp). Include supply,return and relief fans,exhaust
and exhaust hood fans(>t hp), booster fans and fans included as part of make-up air units,dedicated outside air systems(DOAS),energy
recovery ventilators(ERV),and series fan-powered terminal equipment.
B. VA parallel fan-powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak conditions.
C.Fans not directly associated with the delivery and removal of conditioned air,such as condenser fans, do not need to be included in the fan
power total.
D. Fan power calculations are not required for non-central air HVAC systems such as 4-pipe fan coils and variable refrigerant flow(VRF)systems
unless individual fan systems are greater than 5hp.
E. In the Brake Horsepower Allowance Adjustments table,if a Device Type is selected that has an Assigned Pressure Drop,this value will autofill
into the Assigned Pressure Drop cell and the Calculated Pressure Drop cell will be write-protected.If the Device Type requires a Calculated
Pressure Drop, then enter this value into the Calculated Pressure Drop cell and the Assigned Pressure Drop cell with be write-protected.
F.Refer to FAQ section of MECH-FANSYS-DOC for additional instructions.
2015 Washington State Energv Lode Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1
' Design • • Calculatl% • ' '
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all RRevised January 2017
Project Title: Boys&Girls Club-Arlington Date 4/3/2017
The following information shall be included in the load calculation program summary submitted with For Building Dept. Use
the permit documents. If a load calculation summary is not available,provide the required information
below.
Heating Design Cooling Design
Load in Btu/h(Note Load in Btu/h(Note Calculation Method
Equip.ID Area(s)Served 1) 1) (Note 2) Notes
1 Office 100,000 61,100 Existing unit old unit provided sufficient
Note 1-Design load shall account for the building envelope,lighting, ventilation and occupancy loads of the space(s)served by the
mechanical system.Heating and cooling loads shall be adjusted to account for load reduction achieved by an energy recovery
system,if applicable.
Note 2-Computer load calculation program, worksheet(identify source),or equivalent computation procedure in accordance with ASHRAE
Standard 183.
�.� ri
�L.• .1 ;'
M
LWZIMU4 MUM -sapoo leool Noago•aopou jnogflm abuego of joafgns si uopewjo;ul 0'6'9'h loot'sales tieflun
eouepinb �R uolleuaaolul Ieuolllppe JO;anilelueseidai sales ao aolncip1slp bulAlddns anoA Ioeluo0
-papuauauaooaa sl uelolugoal pauleil Ajoloe;e Aq buluolssiwwoo pue do-Iaels luawdlnb3
(aau!l Ion(] .,i,) palelnsul Alin
d '(paalnbaa
aaagnn) hued a9suapuo0 palelnsul 'ame dol
0903Z :IapOVV m@N
(99
-91,-AM '2AgiMPA3d -i-ifld) 6999me :IapoW PIO
aaldepy gan0 9009-90OZ-1,100 SLl`da 9 £
(palunoVV
Iona ao IIun mol}umoa)Il>i POOH ql!m aadwea jalle2j oulawoaeg 0I,1,OGH 6 >1001S NI £
Savo(] ssaooy PiepuelS .
ued idea(] I99IS pazluenle(] .
IIoO a0leaOden3 ul;wnuluanly/egnl
aaddo0 'IIoO aasuepuo0 wnulwnld IId Iauuegooao1V4
saosuaS ainleaadwal jiV aoopin0
pue 'alb'uanla�A 'alb'ebjegosl(] bulpnloul aalloiluo0 3S®4IlolldwiS .
saalll3 Aememoagl"i,
J9MO19 anla(]Ioaal(] dH 6
(669 VOVVb 'tbZ 8III1 eluAOhE0 '960Z 0031 '£b0Z-V06
3`d IHSV slaaVV) O!Isou6el(] '8 uolloala(] Ilned aazlu.fouoo3 gl!m
(aadwe(]3alla�l oujewoaeg ON) POOH pue aazluaouoo3 glne Aj(] • G?IVE)Il
09-b-0£Z/80Z 'laalS wnuluanly se(] 96elS albulS (]NV
'Indul HEIN 9ZI '2J33S O'K/b33 8'bl- 'uol 9 'aau011lPuOO JIV 3-Il1d3S
y01,-,-�] pa6e){0ed albulS eullunS IlewS �aok '6u11000 e6elS albulS l,Vl,VvVl,01-` UH0903Z >IOOlS NI £
uolldlaosaa #IapoW #Bel Alt)
afied /uemwnS lejj!wgnS
MM-WSS3
aasegoand/Iua110
60960MM
aagwnN Ioafoad
6A38 b'M'N0i9Ni-fav-omo sidie'8 SA08
z Gw8N loafoad
96MZlMM
(]lea
Permit#: 1774
Permit Date: 12/12/17
Permit Type: COMMERCIAL MECHANICAL
Project Name: Arlington Boys and Girls Club
Applicant Name: Evergreen State Heat and A/C
Applicant Address: 2120 Pacific Avenue
Applicant, City, State, Zip: Everett,WA 98201
Contact: Mark Payne
Phone: 425-252-3114
Email: mark@essmwa.com
Scope of Work: Replace Packaged Unit
Valuation: 12000.00
Square Feet: 0
Number of Stories: 0
Construction Type:
Occupancy Group:
ID Code:
Permit Issued: 12/18/2017
Permit Expires:
Form Permit Type:
Status: COMPLETE
Assigned To: Kristin Foster
Property
Parcel# Address Legal Description Owner Name Owner Phone Zoning
31052200103100 18513 59TH AVE NE ARLINGTON CITY 431 Airports&
OF Flying Fields
Contractors
Contractor Primary Contact Phone Address Contractor Type License License#
Evergreen State Heat MECHANICAL Labor and
Mark Payne 425-252-3114 2120 Pacific Ave EVERGSS928RN
and A/C CONTRACTOR Industries
Inspections
Date Inspection Type Description Scheduled Date Completed Date Inspector Status
C10.
12/21/2017 MECHANICAL 12/21/2017 BUILDING Approved
ROUGH-IN
Plan Reviews
Date Review Type Description Assigned To Review Status
12/12/2017 COMMERCIAL BUILDING
MECHANICAL
Fees
Fee Description Notes Amount
Mechanical Fee(Enter Fixture Fee) $25.00
Mechanical Base Permit Fee $25.00
Mechanical Commercial Plan Review Table 4-1 $250.00
Processing/Technology $25.00
Total $325.00
Attached Letters
Date Letter Description
12/14/2017 Building Permit
Payments
Date Paid By Description Payment Type Accepted By Amount
12/18/2017 Darlene Sallo 67730748 cc $325.00
Outstanding Balance $0.00
Uploaded Files
Date File Name
12/18/2017 2861837-1774 Issued Permit.pdf
12/12/2017 2849743-1774 Application.pdf