HomeMy WebLinkAbout19322 VISTA DR_BLD1730_2026 RESIDENTIAL PLUMBING
PERMIT APPLICATION
Department of Community& Economic Development
City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551
THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW PLUMBING INSTALLATION FOR
EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL
INFORMATION.
Project Address: Z?3 22 U)S !'�✓'
Project Description:
Owner: JU a,✓► Cd.r
Address- /9,322- Vpgj(;�- JDy- City:�,Y�¢a,., State:t,//.)- Zip Code: 9b�2 3
Phone: W5 6/® ��� - Email:
Applicant: —Juao C&"✓las C'C'k%e-V-i/C'C -
Addres&/1✓Tz City: State: Zip Code:
Phone: Email-
CONTRACTOR INFORMATION
Contractor Name: _� C1 Vl-"(!,
Address: City: State- Zip Code:
License Number: Expiration:
Phone: Email:
STAFF USE ONLY
Permit �L �) Accepted by: Date
REV 2015 Page 1 of 2
'Y RESIDENTIAL PLUMBING
PERMIT APPLICATION
y�l�NG1� Department of Community& Economic
p y co om►c Development
City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551
Plumbing Section (check all that apply)
(Check all that apply and indicate the number of fixtures proposed)
❑ Bath/Shower Combo (4.0) x 0 Sink(1.5) x j
Shower(2.0) x LJ Lavatory(1.0) x
❑ Clothes Washer(4.0) x ❑ Water Closet(2.5) x 1
I
❑ Dishwasher(1.5) x 0 Water Heater x
[j Hose Bibb (2.5) x
Water Heater Model#
Other(list) x
Proposed Water Piping Size:
Proposed Piping Material:
Proposed DWV Material:
Proposed DWV Size:
• All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019
• All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV)
• Cross-Connection-Control may be required
Applicant Signature. Date:
I hereby certify that the nfo ation is correct and that the construction, installation for the above mentioned
property will be in acc ce with the applicable laws of the City of Arlington and the State of Washington.
REV 2015 Page 2 of 2
- ° CITY OF ARLINGTON
238 N. OLYMPIC AVE-ARLINGTON, WA. 98223
PHONE; (360)403-3551
BUILDING PERMIT
Address:19322 Vista Drive Permit#:1730
Parcel#:00898100007400 Valuation:0.00
OWNER APPLICANT CONTRACTOR
Name:GUTIERREZ JUAN Name:Juan Carlos Gutierrz Name:Juan Carlos Gutierrz
CARLOS/EVANGELINA
Address: 19322 VISTA DRIVE Address:19322 Vista Drive Address: 19322 Vista Drive
City,State Zip:ARLINGTON,WA 98223 City,State Zip:Arlington,WA 98223 City,State Zip:Arlington,WA 98223
Phone: Phone: Phone:
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Name: Name: Juan Carlos Gutierrz
Address: Address: 19322 Vista Drive
City,State,Zip: City,State,Zip:Arlington,WA 98223
Phone: Phone:
LIC#: EXP: LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Residential Plumbing CODE YEAR: 2015
STORIES: CONST.TYPE:
DWELLING UNITS: 1 OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED
THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO
WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110.
SA TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form
�ndd d Ci f Ar ton#3101,
Van Cor �vjy'e✓rCL //-/;Z•( j f
Signature Print Name Date Released By tc
CONDITIONS
See red-lined drawings and attached Uniform Plumbing Code section 402.5. Adhere to approved plans.
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY, ANY
CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
11/15/2017 Plumbing Permit Base Fee $25.00
11/15/2017 Plumbing Permit Fee(Enter Fixture Fee) $24.00
11/15/2017 Processing/Technology Fee $25.00
Total Due: $74.00
Total Payment: $0.00
Balance Due: $74.00
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
CITY OF ARLINGTON
-ARLINGTON, WA. 98223 238 N. OLYMPIC AVE
PHONE; (360) 403-3551
BUILDING PERMIT
Address:19322 Vista Drive Permit#:1730
Parcel#:00898100007400 Valuation:0.00
OWNER APPLICANT CONTRACTOR
Name:GUTIEERREZ JUAN Name:Juan Carlos Gutierrz Name:Juan Carlos Gutierrz
CARLOS/EVANGELINA
Address: 19322 VISTA DRIVE Address:19322 Vista Drive Address: 19322 Vista Drive
City,State Zip:ARLINGTON,WA 98223 City,State Zip:Arlington,WA 98223 City,State Zip:Arlington,WA 98223
Phone: Phone: Phone:
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Name: Name: Juan Carlos Gutierrz
Address: Address: 19322 Vista Drive
City,State,Zip: City,State,Zip:Arlington,WA 98223
Phone: Phone:
LIC#: EXP: LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Residential Plumbing CODE YEAR: 2015
STORIES: CONST.TYPE:
DWELLING UNITS: 1 OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED
THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO
WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRCI10.
SA TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form
nd cod d Cit 'f Ar ton#3101.
75'vah C' 1 tarely'Cr�CL ///�•l
Signature Print Name Date Released By Ddte
CONDITIONS
See red-lined drawings and attached Uniform Plumbing Code section 402.5. Adhere to approved plans.
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY
CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
11/15/2017 Plumbing Permit Base Fee $25.00
11/15/2017 Plumbing Permit Fee(Enter Fixture Fee) $24.00
11/15/2017 Processing/Technology Fee $25.00
Total Due: $74.00
Total Payment: $0.00
Balance Due: $74.00
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
Permit Information
Date 11/6/2017
Permit Number 1730
Project Name Gutierrez
Applicant Name Juan Carlos Gutierrz
Applicant Address 19322 Vista Drive
City,State,Zip Arlington,WA 98223
Contact Juan Carlos Gutierrez
Phone
Email evita_balderas@hotmail.com
Permit Type Residential Plumbing
Site Address 19322 Vista Drive
Valuation 0.00
Status Applied
Permit Issued
Permit Expires
Square Feet 0
Type of Construction/Occupancy Load
Number of Stories 1
Proposed Use Add sink and toilet to garage
Assigned To Launa Peterson
Property
Parcel Address Subdivision Lot Owner
00898100007400 19322 VISTA DR ICROWN RIDGE ESTATES DIV 1 174 IGUTIERREZ JUAN CARLOS/EVANGELINA
Review
Date Type Description I Tar et Date Completed Date Assigned To Status
11/6/2017 lResidential Plumbing 11/20/2017 <evin Olander n Review
Uploaded Files Upload File
Date File Uploaded By I
11/6/2017 10:21:55 AM 11730 Aoplication.udf Peterson,Launa I x
RESIDENTIAL PLUMBING
PERMIT APPLICATION
lr ' Department of Community& Economic Development
City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551
THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW PLUMBING INSTALLATION FOR
EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL
INFORMATION.
Project Address-_ S�+ I"DV-
Project Description:
Owner: -Jig owlc�r 1 c� �'��l'eV'✓L'2
Address: /f322. ViQk6- Dv- City:,q�,�,„y �vh State:l,v/� Zip Code. 9822 3
Phone: y-5 (a/c, Email:
Applicant: Juan C&/L aS Q��llerec-c
Address:,4 5�a4-lam City: State: Zip Code:
Phone: Email:
CONTRACTOR INFORMATION
Contractor Name: q V"e'
Address- City- State: Zip Code:
License Number: Expiration.
Phone: Email:
STAFF USE ONLY Received
Permit#: J Accepted by: Date NOV 92 2017
REV 2015 Page 1 of 2
I
RESIDENTIAL PLUMBING
PERMIT APPLICATION
De
pCommunity&Economic Development
City of Arlington • 18204 59th Ave NE •Arlington, WA 98223• Phone(360)403-3551
Plumbing Section (check all that apply)
(Check all that apply and indicate the number of fixtures proposed)
❑ Bath/Shower Combo (4.0) x ❑ Sink(1.5) x
❑ Shower(2.0) x ❑ Lavatory(1.0) x
❑ Clothes Washer(4.0) x ❑ Water Closet(2.5) x '
I
❑ Dishwasher(1.5) x ❑ Water Heater x
Hose Bibb (2.5) x
Water Heater Model#
Other(list) x
Proposed Water Piping Size:
Proposed Piping Material:
Proposed DWV Material:
Proposed DWV Size:
• All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019
• All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV)
• Cross-Connection-Control may be required
Applicant Signature: Date: 2-
I hereby certify that the a nfo mation is correct and that the construction, installation for the above mentioned
property will be in acc oce with the applicable laws of the City of Arlington and the State of Washington.
REV 2015 Page 2 of 2
l +
_ i•lith8100007A00 '�
04
IL
if 1,liri
RD
sr
l � V
.w,.�, CITY OF ARLINGTON
- • � f., ��� ���� NG DEPARTMENT
APPROVED
I:
/e Of Your Building
_ NO CHANGES AUTHORIZES --
ANTI.
UNLESSL'�4PFfRF VED BY 7Hfi
8�G.bE9.52�_ Nvmn-�.iTic�:i in CO BUILDING INSftCTOR
�- (A
Z,
r �
4�e 51�6 - � \W
fit, Ohl 17'—
CD;
-� ` N -P
W N
<
J cD.
G hmL IL
CHAPTER 4
PLUMBING FIXTURES AND FIXTURE FITTINGS
401.0 Materials—General Requirements. material and designed to accommodate an adequately sized
401.1 Quality of Fixtures.Plumbing fixtures shall be con- gasket. Gasket material shall be neoprene, felt, or similar
structed of dense,durable,non-absorbent materials and shall approved types.
have smooth, impervious surfaces, free from unnecessary 402.6.1 Closet Rings (Closet Flanges). Closet
concealed fouling surfaces.Except as permitted elsewhere in rings(closet flanges)for water closets or similar fixtures
this code,fixtures shall comply with the quality and design of shall be of an approved type and shall be bronze,copper,
nationally recognized applicable standards referenced in hard lead, cast-iron, galvanized malleable iron, ABS,
Table 1401.1. PVC,or other approved materials.Each such closet ring
401.2 Lead. Sheet lead shall be not less than the following: (closet flange)shall be approximately 7 inches(178 mm)
For safe pans not less than 4 pounds per square foot (lb/ft2) in diameter and,where installed,shall,together with the
(19 kg/mz) or ''/16 of an inch (1.6 mm.) thick. (See Table soil pipe,present a 11/2 inch(38 mm)wide flange or face
1401.1) to receive the fixture gasket or closet seal.
Caulked-on closet rings(closet flanges)shall be not
402.0 Installation. less than 1/4 of an inch(6.4 mm)thick and not less than 2
inches(51 mm)in overall depth.
402.1 Cleaning. Plumbing fixtures shall be installed in a Closet rings(closet flanges)shall be burned or sol-
manner to afford easy access for repairs and cleaning.Pipes dered to lead bends or stubs,shall be caulked to cast-iron
from fixtures shall be run to the nearest wall. soil pipe, shall be solvent cemented to ABS and PVC,
402.2 Joints.Where a fixture comes in contact with the wall and shall be screwed or fastened in an approved manner
or floor, the joint between the fixture and the wall or floor to other materials.
shall be made watertight. Closet bends or stubs shall be cut off so as to pres-
402.3 Securing Fixtures. Floor-outlet or floor-mounted ent a smooth surface even with the top of the closet ring
fixtures shall be rigidly secured to the drainage connection before rough inspection is called.
and to the floor,where so designed,by screws or bolts of cop- Closet rings (closet flanges) shall be adequately
per,brass,or other equally corrosion-resistant material.
designed and secured to support fixtures connected
402.4 Wall-Hung Fixtures. Wall-hung fixtures shall be thereto.
rigidly supported by metal supporting members so that no 402.6.2 Securing Closet Flanges. Closet screws,
strain is transmitted to the connections.Flush tanks and sim-
ilar appurtenances shall be secured by approved non-corro- bolts, washers, and similar fasteners shall be of brass,
sive screws or bolts. copper,or other listed,equally corrosion-resistant mate-
402.5 Setting.Fixtures shall be set level and in proper align- rials. Screws and bolts shall be of a size and number to
ment with reference to adjacent walls. No water closet or properly support the fixture installed.
bidet shall be set closer than 15 inches(381 mm)from its cen- 402.6.3 Securing Floor-Mounted, Back-Outlet
ter to a side wall or obstruction nor closer than 30 inches(762 Water Closet Bowls. Floor-mounted, back-outlet
mm) center to center to a similar fixture. The clear space in water closet bowls shall be set level with an angle of 90
front of a water closet or bidet shall be not less than 24 inches degrees(1.57 rad)between the floor and wall at the cen-
(610 mm).No urinal shall be set closer than 12 inches (305 terline of the fixture outlet.The floor and wall shall have
mm)from its center to a side wall or partition nor closer than a flat mounting surface not less than 5 inches(127 mm)to
24 inches(610 mm)center to center. the right and left of the fixture outlet centerline.The fix-
Exception: The installation of paper dispensers or accessi- ture shall be secured to the wall outlet flange or drainage
bility grab bars shall not be considered obstructions. connection and to the floor by corrosion-resistant screws
402.E Flanged Fixture Connections. Fixture connec-
or bolts.The closet flange shall be secured to a firm base.
tions between drainage pipes and water closets, floor outlet Where floor-mounted,back-outlet water closets are
service sinks and urinals shall be made by means of approved used,the soil pipe shall be not less than 3 inches(80 mm)
brass,hard lead,ABS,PVC,or iron flanges caulked,soldered, in diameter. Offset, eccentric, or reducing floor flanges
solvent cemented;rubber compression gaskets;or screwed to shall not be used.
the drainage pipe. The connection shall be bolted with an 402.7 Accessible Plumbing Facilities. Where accessi-
approved gasket, washer, or setting compound between the ble facilities are required in applicable building regulations,
fixture and the connection.The bottom of the flange shall be the facilities shall be installed in accordance with those reg-
set on an approved firm base. ulations.
Wall-mounted water closet fixtures shall be securely 402.8 Supply Fittings. The supply lines and fittings for
bolted to an approved carrier fitting. The connecting pipe every plumbing fixture shall be so installed as to prevent
between the carrier fitting and the fixture shall be an approved backflow in accordance with Chapter 6.
UNIFORM PLUMBING CODE 25
Permit#: 1730
Permit Date: 11/06/17
Permit Type: RESIDENTIAL PLUMBING
Project Name: Gutierrez
Applicant Name: Juan Carlos Gutierrz
Applicant Address: 19322 Vista Drive
Applicant, City, State, Zip: Arlington,WA 98223
Contact: Juan Carlos Gutierrez
Phone:
Email: evita balderas@hotmail.com
Scope of Work: Add sink and toilet to garage
Valuation: 0.00
Square Feet: 0
Number of Stories: 1
Construction Type:
Occupancy Group:
ID Code:
Permit Issued: 11/17/2017
Permit Expires:
Form Permit Type:
Status: COMPLETE
Assigned To: Launa Black
Property
Parcel# Address Legal Description Owner Name Owner Phone Zoning
Section 14 Township 31
Range 05 CROWN RIDGE GUTIERREZ JUAN Single Family
00898100007400 19322 VISTA DR ESTATES DIV 1 BLK 000 CARLOS/EVANGELINA Residence-
D-00 LOT 74 Detached
Contractors
Contractor Primary Contact Phone Address Contractor Type License License
#
Juan Carlos Gutierrz Juan CarlosGutierrz 19322 Vista Drive OWNER
Inspections
Date Inspection Type Description Scheduled Date Completed Date Inspector Status
R20.
11/27/2017 ADDITION/ALTERATION 11/27/2017 BUILDING Completed
FINAL
Plan Reviews
Date Review Type Description Assigned To Review Status
11/06/2017 RESIDENTIAL See red-lined drawing and attached information. BUILDING
PLUMBING
Fees
Fee Description Notes Amount
Plumbing Base Permit Fee $25.00
Mechanical Commercial Permit Table 4-7;Per Unit 2 @$12 $24.00
Processing/Technology $25.00
Total $74.00
Attached Letters
Date Letter Description
11/15/2017 Building Permit
Payments
Date Paid By Description Payment Type Accepted By Amount
11/17/2017 Juancarlos Gutierrez 67351102 cc $74.00
Outstanding Balance $0.00
Notes
Date Note Created By:
11/16/2017 Entailed that permit is ready to issue. KF Kristin Foster
Uploaded Files
Date File Name
11/17/2017 2787155-1730 Issued Permit.pdf
11/06/2017 2756674-1730 Application.pdf
Date: 03/19/2026
Permit#: 1730
Permit Date: 11/06/2017
Review Date: 11/06/2017
Permit Type: RESIDENTIAL PLUMBING
Review Type: RESIDENTIAL PLUMBING
Target Date: 11/20/2017
Scheduled Time: 00:00
Completed Date: 11/15/2017
Description: See red-lined drawing and attached information.
Review Status:
Assigned To: BUILDING
Time In: 00:00
Time Out: 00:00
Hours: 0.0
Property Information
Parcel#: 00898100007400 GUTIERREZ JUAN CARLOS/EVANGELINA
GUTIERREZ JUAN CARLOS/EVANGELINA 19322 VISTA DRIVE
19322 VISTA DR ARLINGTON, WA 98223
Zoning: 111 Single Family Residence -
DetachedLot: 74131ock: