Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
17922 59th Drive NE_BLD1664_2026
AN COMMERCIAL PLUMBING PERMIT APPLICATION �t I N Cn 0� Department of Community&Economic Development City of Arlington - 18204 59th Ave NE-Arlington, WA 98223 - Phone (360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2) SETS OF CONSTRUCTION DRAWINGS, AND TWO(2) SETS OF FIXTURE SPECIFICATIONS (CUT SHEETS). CALCULATIONS ARE REQUIRED FOR GREASE INTERCEPTOR/F APPLICABLE. Type of Permit: 0 New Installation Addition/Alteration Industrial Project Address: /2�2 2 Parcel ID#: Lot#: Subdivision: Project Description: Valuation: , Owner: Phone Number: Address: City: State: ZiipI Code: Contact Person: Phone Number: Cell Phone: E-mail: Address: City: State: Zip Code: Contractor: /_� Phone Number: 2 lZ— Cell Phone: 2 U6-27Z' �Z�4 Email: / /��� Address:6 zZ �iXn 9�4 //��e2 City:Lti�c��>�y'�State:� Zip Code:,��i 2SU� Contractor License Number.ZZ W6_- 2E ', ,Z(2 D Expiration Date: 1214I/ 32 2, VZ—' Please indicate number of fixtures: Water Closet Floor Sink Sump Hose Bibb Miscellaneous Lavatory Laundry Tub 2 Washer Water Heater Z Grease Trap Urinal Interceptor Sink Med Gas _ Drinking Fountain_ Floor Drain Dishwasher Backflow Shower Other 6/16LP Page 2 of 3 COMMERCIAL PLUMBING ® PERMIT APPLICATION Department of Community&Economic Development City of Arlington • 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 WHEN is a PLUMBING PERMIT REQUIRED? The City of Arlington requires a plumbing permit before a plumbing system or fixture is installed, altered, or remodeled. This also includes replacement of a Hot Water Tank. The City of Arlington does not require a permit to stop leaks or clear stoppages, unless the piping being repaired is altered or replaced. PLUMBING PLAN REVIEW IS REQUIRED FOR THE FOLLOWING PROJECTS 1. New Commercial Buildings 2. New Multi-Family Buildings 3. Roof Drains and Overflow Systems 4. Tenant Improvements 5. Installation of Medical Gas Systems -6. ' Installation of Commercial Kitchen's and Deli's 7. Installation of Grease Traps 8. Installation of Grease Interceptors 9. Installation of Sumps 10. Installation of Cross Connection Backflow Devices SUBMIT TWO (2) COPIES OF THE FOLLOWING FOR PLUMBING PLAN REVIEW: ❑ Plumbing plans or drawings. (Minimum plan size is 18" X 24" scale, W scale for details.) ❑ Provide one set of plumbing drawings maximum size 11" X 17" ❑ Size of sanitary and potable water systems. ❑ Location, type and specifications (cut sheets) of proposed fixtures and equipment. ❑ Riser diagram of waste and vent, potable water and rain water systems, including sizes. ❑ Medical gas piping riser diagram indicating type of gas, storage room and size of piping. ❑ Location and type of all backflow assemblies for each fixture. I hereby certify that I have read and examined this application and know the same to be true and correct and I am authorized to apply for this permit. 6/16LP Page 1 of 3 COMMERCIAL PLUMBING Y o PERMIT APPLICATION LtNG`S Department of Community&Economic Development City of Arlington • 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 PROPOSED BUILDING USE New Commercial ❑ Restaurant ❑ Automotive Based ❑ Commercial Addition/Alteration ❑ Office ❑ Machine Shop Industrial ❑ Medical ❑ Other: CROSS CONNECTION Please check all appliances that are proposed or are permanently connected to the water supply. ❑ Ice Machine ❑ Dialysis Equip. ❑ Air washers ❑ Swimming ❑ Fire Sprinkler Pools ❑ Coffee Steam Sprinkler Urn/Espresso ❑ Hydrotherapy Equip. ❑ Generators ❑ Hot Tub/Spa ❑ w/chemicals ❑ Carbonated Bev. ❑ Dental Equip. ❑ Dye Vats ❑ Aquarium ❑ Lawn Irrigation ❑ Fume Hoods ❑ Laboratory Equip. ❑ Pressure ❑ Decorative ❑ Well on Washers Fountain property ❑ Degreasers ❑ Autoclave/Sterilizers ❑ Cooling Towers ❑ Other: WASTEWATER DISCHARGE 1. Does the plumbing system currently have a grease interceptor? ❑ Yes L� No ❑ Don't Know Date grease trap/interceptor was last cleaned (provide service record): 2. Does the plumbing system currently have an oil/water separator? ❑ Yes No ❑ Don't Know 3. Date oil/water separator was last cleaned (provide service record): 4. Is water used in the business process (washing, rinsing,cooling)? 0 Yes � No ❑ Don't Know 171 5. Does your business require a NPDES permit? L-aj Yes ❑ No ❑ Don't Know I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington. Applicants Signature Date Print Applicants Name FOR STAFF USE ONLY Received '017 Permit# Ac pted Amount Received Receipt# Date Received 6/16LP Page 3 of 3 i ,: ,. . � : 1 CADET° PROTM RIGHT HEIGHT° ELONGATED TOILET ® BARRIER FREE VITREOUS CHINA CADET° PROT' RIGHT HEIGHT° ELONGATED TOILET ❑ 215AA.004 • Features the Cadet" Flushing System : •Vitreous china •Low consumption (6.0 Lpf/1.6 gpf) toilet •Trade exclusive tank • PowerWashO rim scrubs bowl with each flush 4 • Robust metal trip lever& metal shank fill valve • Includes EZ-Install Tools w/color match bowl caps - • EverClean°surface included •3"flush valve • Fully-glazed 2-1/8"trapway • 16-1/2" rim height for accessible applications ; • 12" (305mm) rough-in r •Generous 9" x 8" water surface area •Chrome finish trip lever is supplied • 1,000g MaP Score" at 1.6 gpf .,_. •5 year warranty FINISHED WALL 30-1/6" �/3517A.101 Right Height°Elongated Bowl J= 8-718" (767mm) 17-318• 4188A.004 Tank (S) E c226mm) {441mm) N i0 Nominal Dimensions: 767 x 441 x 771mm (30-1/8" x 17-3/8" x 30-3/8") i' (<�o'm�,) i 30-3W '�C/l OF SEAT POST HOLES (771 mm) J. Fixture only, seat and supply sold separately 140mm(5-1/2'CENTERS) AS SUPPLY Alternative Tank Configuration Available: s 1 ❑ 4188A.054 Tank complete with Aquaguard Liner • Is.,W 35'6mm ❑ 4188A.064 Tank complete with tank cover (419mm) (254mm)I locking device , ❑ 4188A.074 Tank complete with Aquaguard Liner 1 I and tank cover locking device 7.7/t6' ,3-5/B'LLJ FINISHED S. k 4188A.005 Tan om lete with trip lever located "(Isue—'''—(347Mm) FLOOR (152mm) on right side ( p p (305mmi OF OUTLET 44m) ❑ 4188A.065 Tan complete with tank cover locking device and trip lever located on right side NOTES: THIS TOILET IS DESIGNED TO ROUGH-IN AT A MINIMUM DIMENSION OF 305MM(12")FROM FINISHED WALL TO C/L OF OUTLET. Compliance Certifications - SUPPLY NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED SEPARATELY. DIMENSION SHOWN FOR LOCATION OF SUPPLY IS SUGGESTED. Meets or Exceeds the Following Specifications: IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of •ASME A112.19.2-2008/CSA B45.1-08 for Vitreous tolerances established by ANSI Standard A112.19.2. China Fixtures These measurements are subject to change or cancellation.No responsibility is assumed for use of superseded or voided pages. "Maximum Performance(MaP)testing performed by ® MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND Maximum R&T Lab.MaP Report conducted or Ve by ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE Consulting, Inc.and Koeller and Company. BUILDING FACILITIES-CHECK LOCAL CODES. To Be Specified: ❑ Color:❑White ❑ Bone ❑Linen ❑ Black ❑ Seat: #5321.110 EverClean°Elongated Seat with Slow Close Snap-Off Hinges ❑ Supply with stop: Cadet' K188 ©2013 AS America Inc. Rev.5/13 LUCERNE TM WALL-HUNG LAVATORY VITREOUS CHINA BARRIER FREE LUCERNETM WALL-HUNG LAVATORY • Wall-hung sink • Vitreous china • Front overflow ''}� • D-shaped bowl _ • Self-draining deck area with contoured back and side splash shields • Faucet ledge • Compliant with Texas accessibility standard (TAS) for children age group 13 and up Faucet holes on 203mm(8")centers(Illus.): ❑ 0356.028 For exposed bracket support Shown with 4801.862 Amarilis Heritage faucet with Triune Cross handles (not included) ❑ 0356.015 For wall hanger(included) or concealed arms support ❑ 0356.915 For wall hanger(included) or 0356.028 concealed arms support • Less overflow Faucet holes on 102mm (4")centers: 0355.027 For exposed bracket support 0355.012 For wall hanger(included) or concealed arms support . ❑ 0355.912 For wall hanger(included) or concealed arms support • Less overflow Single center faucet hole(Illus.): ❑ 0356.041 For exposed bracket support Shown with 1340.000 metering faucet low, (not included) ❑ 0356.421 For wall hanger(included) or concealed arms support ❑ 0356.921 For wall hanger(included) or concealed arms support • Less overflow 0356.041 ❑ 0356.439 For wall hanger(included) or concealed arms support SEE FOLLOWING PAGES FOR ROUGHING-IN DIMENSIONS •Single faucet hole on right ❑ 0356.066 For exposed bracket support •Single faucet hole on right To Be Specified: ❑ Color: ❑White Nominal Dimensions: ❑ Faucet": 521 x 464mm ❑ Faucet Finish: (20-1/2"x 18-1/4") ❑ Supplies: Bowl sizes: ❑ 1-1/4"Trap: 381mm (15")wide ❑ Nipple: 254mm (10")front to back ❑ Bracket Support(by others): 165mm (6-1/2") deep ❑ Concealed Arms Support(by others): Compliance Certifications - Meets or Exceeds the Following Specifications: • ASME Al12.19.2/CSA 1345.1 for Vitreous •See faucet section for additional models available China Fixtures ® MEETS THE AMERICANS WITH DISABILITIES ACT GUIDE- LINES AND ANSI Al17.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES-CHECK LOCAL CODES. Top of front rim mounted 864mm(34")from finished floor. - -- M37 ©2016 AS America Inc. spec_0355-0356 Lucerne WallHung Lays Rev.A 8/16 LUCERNE TM Su WALL-HUNG LAVATORY VITREOUS CHINA BARRIER FREE 0356.028 8"CTRS FOR EXPOSED BRACKET SUPPORT 0355.027 4"CTRS FOR EXPOSED BRACKET SUPPORT 0356.015 8" CTRS FOR WALL HANGER �-0355.012 4"CTRS FOR WALL HANGER OR OR CONCEALED ARMS CONCEALED ARMS 0356.915 LESS OVERFLOW 0355.912 LESS OVERFLOW � t 66mm � 96mm FINISHEU•1(4) (3-3/6') •-FIHISHED(4') 133/0) rIf�ISHEO WALL I 203mm WALL 207m WALL 152mm I 152mm (61 , (6•) I 464mm ION— 464mm 152 mm I 203mm (1e-114') 152mm 1 (4•) (16-1/4') (s•) I (e•t ls•1 1 I I 1 I r emm emm (5f16') (6)25mm (6)25mm (1')DIA 11')DIA ) ACCESS 1 t3mm ACCESS 13mm HOLES FOR 521mm (1r2 t HOLES FOR 521mm IIre CONE AflMS (20-112') CONC (20-1/2') ARMS 425mm 425mm (16-3/4•) (16-3/4') 267mm 267mm 110-112') 64mm(2•1/e7 DIA (10-1 i2•) 114mm HOLES FOR IIM1mm 14•N2') CONCEALEDARMS F (4.112') 64mm 12.1M'1 DIA HOLES IQ (44m ^_ _ CONCEALED ARMS 1-3/4") 25m' (1.34) 14 (1 (4') _ 26mm 2emm 1 I /��1 791 ♦ II i�1 131`1 f / •29emm 19a/e'1 T� ♦ £ mn 206mmm � (e•tfa') 30mm tOJ lnm(318•) I (1uj/2m (1-1/2') DIA.ANCHOR 1HO l (11-1/4'1 OIA,ANCHOR SCREW HOLES •352mm SCREW HOLES A 203mm 203mm S-9 HANGER I— (e,) 5-9 HANGER 27mm%14 T "+- ♦ 27mm x/1 ♦ T ♦ _ (1-1/16'If 5/16")SLOTS (1.1/16 z 5/16`) �.! SUPPLIES SLOTS / SUPPLIES J E E AS REQUIRED AS REQUIRED E E 767mm(31") 1-1/4'O.D WASTE �1-1/4'O D WASTE 684mm(34') 1•tN'00.WASTE �1•i/4'O.D.WASTE �n OUTLET FOR OUTLET FOR FINISHED OUTLET FOR OUTLET FOR FINISHED DRAIN PLUG POP-UP DRAIN FLOOR ® GRAIN PLUG POP-UP GRAIN FLOOR 18-1/4" FINISHED 18-1/4' /—FINISHED (464mm) WALL (464mm) / WALL 8"MIN. JFREE 34• - (203mm) 34' (864mm) (864mm) 27"MIN. 27"MIN. (686mm) (686mm)6"MAX- MAX. (152mm) 2mm) 9'MIN. MIN. BARRIER FREE (229mm) 9mm) .CLEARANCE 11' (279mm) (279mm) NOTES: *DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND"P"TRAP ARE SUGGESTED. PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS. FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY. CONCEALED ARM SUPPORT AS REQUIRED TO BE FURNISHED BY OTHERS. IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tole f'Inces est abl;,hed by ANSI Standard A112.19.2.These measurements are subject to change or cancellation No wsporlsibilly is assumed for use of superseded or voided pages. ®LAVATORY DESIGNED TO MEET ADA HANDICAPPED GUIDELINES WITH MOUNTING HEIGHT SET AT 864MM(34")ABOVE FINISHED FLOOR. - M38 ©2016 AS America Inc. PART OF `I X I l spec_0355-0356 Lucerne WallHung Lays Rev.A 8/16 RELIANT° 3 SINGLE CONTROL LAVATORY FAUCET <<Ts� MODEL NUMBER: ❑7385.000 Reliant 3 Single Control Centerset Metal Speed Connect°pop-up drain. Metal lever handle. ❑7385.003 Reliant 3 Single Control Centerset Indexed metal lever handle. Grid drain. LESS pop-up hole. ?` )(7385.004 Reliant 3 Single Control Centerset' Indexed metal lever handle. LESS drain &pop-up hole. ❑7385.007 Reliant 3 Single Control Centerset Indexed metal lever handle. LESS drain & pop-up rod. 142 mm J With pop-up hole. (5-5/8") ❑7385.008 Reliant 3 Single Control Centerset Indexed metal lever handle. Metal Speed Connect EXTRA LONG HANDLE pop-up drain. 154 mm (6-1/16") 117 mm__� (4-5/8") TANDARD HANDLE 143 mm (5-5/8") Z'S4 98 mm I 102 mm(3-7/8") (4") 123 mm-� 2-mm-7/8") t �32 mm 30 mm (1-114")DIA. 498 mm (1-1/4") MOUNTING (19-5/8") 63 mm HOLE (2-1/2") PRODUCT FEATURES: BRAIDED Cast Brass Waterway with Flexible Supply Hoses: FLEXIBLE -- Strong and durable. Less potential for leaks. SUPPLY HOSES i g WITH 3/8" Ceramic Disc Valve Cartridge:Assures smooth,precise valve COMPRESSION control and a lifetime of drip-free,free, maintenance-free performance. CONNECTORS � 32 mm OD-- � P- (1-1/4"OD) Adjustable Hot Limit Safety Stop: Limits the amount of hot GENERAL DESCRIPTION: water allowed to mix with cold. Reduces the risk of accidental scalding. All metal body with choice of metal lever, indexed metal Exclusive Speed Connect Metal Drain: lever handle or optional extra long lever handle. .Fewer parts. Installs in less time. Washerless 47 mm ceramic disc valve cartridge with .No adjustments required-seals the first time,every time. integral hot limit safety stop. Durable cast brass waterway. e Flexible stainless steel cable-installs effortlessly in tight spaces. Braided flexible supply hoses with 3/8" compression connections.20" (500 mm)long flexible stainless steel drain Lead Free: Faucet contains<_0.25%total lead content by cable is pre-assembled to faucet body. Metal Speed weighted average. Connect®drain body(on 7385.000&7385.008)with 1-1/4" Simple One-Person Installation: Faucet drops in from top. (32 mm)tail piece. 1.2 gpm/4.5 L/min.maximum flow rate. Quick spin nuts secure faucet in place. SUGGESTED SPECIFICATION Single control lavatory fitting shall feature an all metal body with metal lever handle.Shall feature a cast brass waterway with flexible hose connections.Shall also feature a washerless ceramic disc valve cartridge with integral hot limit safety stop. Shall also feature a metal drain body with stainless steel cable actuation. Fitting shall be American Standard Model#7385. ©2017 AS America,Inc. Revised 5/17 RELIANT® 3 SINGLE CONTROL LAVATORY FAUCET FLOW RATE* CODES AND STANDARDS 1." These products meet or exceed the following codes and standards: 1.0 0.8 ANSI A117.1 s 0.6 ASME A112.18.1 2 °A NSF 61/Section 9 and Annex G a 0.2 CSA 13125.1 0'00 20 ao so eo INLET PRESSURE (PSI) 'Flow.-races shown are for mixed W and cold Finish Options Polished PVD Chrome Brushed Product Nickel Number Description 002 295 7385.000 Reliant 3 Single Control Centerset. Metal lever handle. Metal Speed Connect°pop-up drain. 7385.003 Reliant 3 Single Control Centerset. Indexed(Red/Blue)metal lever handle. Grid drain. LESS pop-up hole. 7385.004 Reliant 3 Single Control Centerset. Indexed(Red/Blue)metal lever handle. LESS drain. LESS pop-up hole. 7385.007 Reliant 3 Single Control Centerset. Indexed(Red/Blue)metal lever handle. LESS drain and pop-up rod.With pop-up hole. 7385.008 Reliant 3 Single Control Centerset. Indexed(Red/Blue)metal lever handle. Metal Speed Connect pop-up drain. Meets the American Disabilities Act� Guidelines and ANSI A117.1 Requirements 7385.000 7385.003 7385.004 7385.007 7385.008, for the physically challenged. Cy' Cam' "PCA—Pressure Compensating ""To modify a product,add suffix after the 4th digit •Indexed(Red/Blue) (ex.2064F05101.002) •Motal Lever Handle •Indexed(Red/Blue) •Indexed(Red/Blue) metal lever handle •Indexed(Red/Blue) SedESS drain, met lever —Modified product models are NOT WaterSense •metall drainnecY' .LESSmetallever drainhandle ,LESSmetalIever d ainhandle •LESS pop-up rod •Speed Conne tie certified. LESS pop-up hole LESS pop-up hole •With pop-up hole metal drain AERATORMODIFICATIONS— Parts Suffix" Parts Suffix" Parts Suffix" Parts Suffix— Parts Suffix Nl `o LESS pop-up drain; XPR XPR 0 o with hole and pop-up rod — — oExtra long handle —LH —LH —LH —LH —LH 0.5 gpm(1.9 Lpm)PCA*Spray F05 —F05 F05 F05 F05 Vandal-Resistant V05 V05 V05 V05 V05 0.5 gpm/1.9 Umin.PCA Aerator — — — — — Vandal-Resistant F10 F10 F10 F10 F10 rn 1.0 gpm(3.8 Umin.)PCA Aerator — — — — — 0 Vandal-Resistant Z. 1.0 gpm(3.8 Umin.)PCA Aerator _V10 —V10 —V10 —V10 —V10 0 Q Vandal-Resistant V12 V12 V12 V12 V12 = 1.2 gpm(4.5 Umin.)PCA Aerator — — — — — 0 v Vandal-Resistant V15 V15 V15 V15 V15 c 1.5 gpm/5.7 Umin.PCA"Aerator — — — — aL Non-Aerated Laminar 1.5 gpm/5.7 Umin.PCA Flow Outlet _L15 _L15 —L15 —L15 —L15 Non-Aerated Vandal-Resistant V05 V05 See 7382.050 V05 V05 0.5 gpm/1.9 Umin.PCA Spray — — — — 2.2 gpm/8.3 Umin Aerator F22 F22 F22 F22 F22 ©2017 AS America,Inc. Revised 5/17 L6AN Wall Mount Wafer Cooler SPEC/FICA T/OHS Models EZ(S)4, EZ(S)8 and EZ(S)D PRODUCT SPECIFICATION RATED FOR INDOOR USE ONLY Self-contained,wall mount electric water cooler.Refrigerated EZ(S)8 models offer a chilling capacity of 8 gallons per hour of 50*F drinking water, based _ upon 80°F inlet water and 90*F ambient. Models EZ(S)D are non-refrigerated ��� and shall deliver non-chilled drinking water. Unit shall meet ADA guidelines. Unit shall be lead-free design which is certified to NSF/ANSI 61 and 372 and meets Federal and State low-lead requirements.Unit shall be certified to ; UL399 and CAN/CSA 22.2 No. 120. Models EZS4 AND EZS8 have self-closing Easy-Touch pushbar controls on front&sides. SM Models EZ4 AND EZ8 have self-closing Easy-Touch pushbar controls on front only. Models EZ(S)D are non-refrigerated.Requires outlet for power cord. STANDARD FEATURES • Easy-Touch pushbar activation • Extra deep basin minimizes splashing;with integral drain • Available with Flexi-Guard"Safety bubbler or Vandal-resistant'bubbler ('includes"VR"code in model no.see chart below) • Valve with built-in flow regulator to provide constant stream from 20 to 105 psi water pressure • Finish options:Impact-resistant vinyl coating or stainless steel wrapper • Rated for Indoor use COOLING SYSTEM (Models EZ(S)(VR)B*(F) and EZ(S)4*(F)only) CONSTRUCTION • Compressor:Hermetically-sealed,reciprocating type,single phase. Stainless Steel basin with integral drain Sealed-in lifetime lubrication. Galvanized structural steel cooler chassis provides structural integrity • Condenser:Fan coaled,copper tube with aluminum fins.Fan motor is Cooler cabinet available as Light Gray Granite Vinyl Clad Steel or permanently lubricated. Stainless Steel(additional cost)construction • Cooling Unit:Combination tube-tank type.Self-cleaning.Continuous Exclusive Flexi-Guard'Safety bubbler(option)utilizes an infused copper tubing with stainless steel tank.Fully insulated with EPS foam anti-microbial pliable polyester elastomer to prevent accidental mouth that meets UL requirements for self-extinguishing material. injuries.Flexes on impact. • Refrigerant Control: Refrigerant R134a is controlled by accurately Vandal-resistant'bubbler(option)is one-piece,heavy duty construction calibrated capillary tube. Warranty: 5 year limited warranty on the unit's refrigeration system. • Temperature Control: Easily accessible enclosed adjustable thermostat Electrical components and water system are warranted for 12 months from is factory preset. Requires no adjustment other than for altitude date of installation or 18 months from factory shipment,whichever date falls requirements. first. Glass Filler I o\ CAPACITIES CHART (option) F O "'U"! us available at extra costA Requires UL399 and Approx. NSF/ANSI Voltage! Chilling** F.L. Rated Factory prep to CAN/CSA 22.2 ADA Model Hertz Capacity Amps Watts Ship receive glass filler No.120 COMPLIANT 61 and 372 Wt. Certified Certified t EZ(S)4*(F) 115V/60Hz 4 GPH 2.0 370 50 lbs. YES t EZ(S)8*(F) 115V/60Hz 8 GPH 4.0 370 51 lbs. YES t EZS8*(F)2JO 220V/50Hz 6.7 GPH 2.0 370 51 lbs. YES ++ t EZS8*(F)3JO 220V/60Hz 8 GPH 2.0 370 51 lbs. YES ++ - t EZSD*(F) 115V/60Hz — — — 25 lbs. I YES t EZD*(F) 115V/60 Hz — — — 25 lbs. YES EZ4* 115V/60Hz 4 GPH 2.0 370 50 lbs. NO EZ8L3JO 220V/60Hz 8 GPH 2.0 370 51 lbs. NO ++ EZSVR8* 115V/60Hz 8 GPH 4.0 370 51 lbs. NO EZSVRD* 115V 160Hz — — I — 125 lbs. I NO •Color code of(L)Light Gray Granite,or(S)Stainless Steel cooler wrapper. '*Based on 80°F inlet water&90•F ambient air temp for 50T chilled drinking water. ++Complies;not third party certified. This specification describes an Elkay product with design,quality and functional t Glass filler available at extra cost,add code(F).Requires factory preparation to receive benefits to the user. When making a comparison of other producer's offerings, glass filler. Note:Vandal-Resistant bubbler models do not have glass filler option. be certain these features are not overlooked. In keeping with our policy of continuing product improvement, 2222 Camden Court Elkay reserves the right to change specification without notice. Oak Brook,IL 60523 ©2016 Elkay Please visit elkay.com for the most current version. 630-572-3192 SPEC12-23 (01/2016) elkay.com Wall Mount Water Cooler ELKAY Models EZ(S)4, EZ(S)8 and EZ(S)D ROUGH-IN DIMENSIONS RATED FOR INDOOR USE ONLY Open space rough-in design permits new installation or replacement of existing fountains and coolers with this Elkay cooler when rough-in is within the outline shown. IMPORTANT! INSTALLER PLEASE NOTE: NOTICE This water cooler has been designed and built to provide water to the user which has This water cooler must be connected to the water supply using a dielectric coupling. not been altered by materials in the cooler waterways. The cooler is furnished with a non-metallic strainer which meets this requirement. The drain trap,which is provided by the installer,should also be plastic to completely The grounding of electrical equipment such as telephone, computers, etc to water isolate the cooler from the building plumbing system. lines is a common procedure. This grounding may be in the building or occur away from the building. This grounding can cause electrical feedback into a water cooler creating an electrolysis which creates a metallic taste or causes an increase in the metal content of the water. This condition is avoidable by installing the cooler using the proper materials as shown below. Model shown with Flexi-Guards'bubbler. FRONT VIEW SIDE VIEW 18 3/8" 191, 467mm 484mm 6 3/8" 6 3/8" HANGER BRACKET 7mm 161 162mm 162mm 2" 51mm B L T E r 1 L E 32 7/8" �{� 835mm 81/16" Lb ORIFICE 205mnn L.� I A HEIGHT _ l RIM C 2813116 HEIGHT D — 732mrr 27" 21 7/8" 686nrrn 556mm F 2„ ADA 51mm REOl16�EMFNT 5 7/8" 1 3 7/8" 150mm 483rrm 98mrn 13151I6" 3„ a43mm 146/rrrn 354mm, 12 1/2" 77mm 318mm 2„ 7" 7" 51 mm 178mm 178mm FINISHED FLOOR REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER LEGEND: A=Recommended Water Supply location.Shut-off Valve(not furnished)to accept 318"O.D.unplated copper tube.Up to 3"(76mm)maximum out from wall. Job Name: B=Recommended Waste Outlet location.To accommodate 1-1/4"nominal drain. Model: Qty. Drain stub 2"(51 mm)out from wall. Contact: C=1-1/4"Trap(not furnished). D=Electrical Supply(3)Wire Recessed Box Duplex Outlet. Approval Signature: E=Insure proper ventilation by maintaining 6"(152mm)minimum clearance from cabinet Notes: louvers to wall. F=7116"(11mm)Bolt Holes forfastening to wall. NOTE:New Installations Must Use Ground Fault Circuit Interrupter(GFCI) 2222 Camden Court Printed in U.S.A, Oak Brook,IL 60523 ©2016 Elkay 630-572-3192 elkay.com /. o NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY ;eAPPROVED PERMIT#: LOT#: DATE: (_o %:; =j JOB ADDRESS: (1q Z Z ' 0 -1 , TYPE OF INSPECTION: ❑ NO PERMIT-STOP WORK-UBTAIN PERMIT.AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH.APPROVED PLANS AND PERMIT -STOP WORK:MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE IT. ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION r THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE/ CI BUILDING DEPT. O PLANNING DEPT. CITY OF ARLINGTON CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:17922 59th Drive NE Permit#:1664 Parcel#:31052200300100 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:City of Arlington Name:Flow Control Plumbing Name:Flow Control Plumbing,LLC Address: 18204 59th Drive NE Address:621 State Route 9 NE PMB C2 Address:621 State Route 9 NE PMB C2 City,State Zip:Arlington,WA 98223 City,State Zip:Lake Stevens,WA 98258 City,State Zip:Lake Stevens,WA 98258 Phone: Phone:425-512-9495 Phone:425-512-9495 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name:Flow Control Plumbing,LLC Address: Address:621 State Route 9 NE PMB C2 City,State,Zip: City,State,Zip:Lake Stevens,WA 98258 Phone: Phone:425-512-9495 LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Plumbing CODE YEAR: 2015 STORIES: 1 CONST.TYPE: DWELLING UNITS: 0 OCC GROUP: BUILDINGS: I OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1I0/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. D 7 Signature Print Name Date R eased By' Date CONDITIONS SEE RED LINED DRAWINGS. ADHERE TO APPROVED PLANS. ADDITIONAL REQUIREMENTS: A RPBA IS REQUIRED BEFORE ANY BRANCHED CONNECTIONS AND MAY BE INSTALLED INSIDE OF THE BUILDING. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 9/27/2017 Plumbing Permit Fee(Enter Fixture Fee) $180.00 9/27/2017 Plumbing Plan Review Fees $350.00 9/27/2017 Processingfrechnology Fee $25.00 9/27/2017 Water Heater $50.00 Total Due: $605.00 Total Payment: $0.00 Balance Due: $605.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 25'-0" ❑ ❑ PWATE BALCONY O O 200'-0" ro 25'-0" 15'-6"� 50'-0" 1' 3" �'-3'6'-0" 11'-0" 11'0"� 50'-0" 34'-0" 6'4'1* EXIT T --� of ---� c 0 in I ILD � In / m J m q J cn Ld , / Z Z 0 \ / � 0) 2 M Q Q O O Lu C c LLj Ln O 3--s-xs--VINSULATED I � I / ~ O /PAINTED METAL DOOR,TYP. I H co TYP.FULLiIFlGHT fl-19 I R-30 FLOOR INSULATION INSULATED IMEflIDfl WALL I ABOVE-WALLTDWAl1D I / 2 r-I Q co I � ml § &HEIGHT GUARDRAIL I I / I ` I / X N � 7'-4" I ' O N 3 X Oa p i €+ t0 Q C -----J Ln J �flp�� �GR �QR"q F� _._ .....,.r... _ _ N''� t - -1 C7 I v' 1 , q DRINKING FOONrAIN r., ._.._....__ U FATU R I N G -----_—_-- M tto in Lu t ------I / I .L N m+' REF. I UTILITY SINK AND I / ��,; Q u a to I DRINKING FOUNTAIN , Q` LLi/ 9 Z 'a�-io OC N�{ Q D U cto LO S C V CO v I / \ All 0 0 rn .N-4 c I ———————————————————————————————— ———————————————— � r^ C c0� I I \ I I PO#: ml in I \ I I I I / OCCUPANCY TYPE: AREA FTz OCC.FACTOR OCC.TOTAL MAX.TRAVEL I 1453 I / ' F-1 25,475 FTz 1/200 128 250' / B-1(MAIN) 585 FT2 1/100 6 300' \ j B-1(MEZZ) 2725 FTz 1/100 28 300, ALIGNW/W END OF WALL I I \ I W/ ALL BELOW 110'-0" \ ev 60 MIN.HOLLOW METAL DOOR W/CLOSER 1-HOUR RATED WALL ASSEMBLY: P TYPE T OWE $ • 6'METAL STUD FRAMING CAVITY INSULATION - UTILITY SINI' . I \ HIM IELEC • I'TYPETGWB I Z I � J 1HIOUfl RATED DO CEILING EXIT E�IT EXIT a 1 Q � E IT � IA Z -Yf 12'-0" G 0 �j m 4'-6" 4'-6" > 2 W 3'-0" CC n a W 17'-0" H Drawn By: LRO U GROUND FLOOR AND MEZZANIN PLANS Stamp LL ID942� FLOOR PLAN O REGISTERED g ARCHITECT Y SCALE:1/8"=1' 0-3 W GARIN A.HCHeNR A� a BTATE OF NANHINGTON O a CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:17922 59th Drive NE Permit#:1664 Parcel#:31052200300100 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:City of Arlington Name:Flow Control Plumbing Name:Flow Control Plumbing,LLC Address: 18204 59th Drive NE Address:621 State Route 9 NE PMB C2 Address:621 State Route 9 NE PMB C2 City,State Zip:Arlington,WA 98223 City,State Zip:Lake Stevens,WA 98258 City,State Zip:Lake Stevens,WA 98258 Phone: Phone:425-512-9495 Phone:425-512-9495 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name:Flow Control Plumbing,LLC Address: Address:621 State Route 9 NE PMB C2 City,State,Zip: City,State,Zip:Lake Stevens,WA 98258 Phone: Phone:425-512-9495 LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Plumbing CODE YEAR: 2015 STORIES: I CONST.TYPE: DWELLING UNITS: 0 OCC GROUP: BUILDINGS: I OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to constructinn And the City ofArll n-must be reported on your sales tax return form and coded City of Arlington#3101. Signature ^ R leased Date SEE RED LINED DRAWIN( ►PLANS.ADDITIONAL REQUIREMENTS: A RPBA IS REQUIRED BE NNECTIONS AND MAY BE INSTALLED DING. THIS PERMIT AUTHORIZS ONLY T ✓ORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOI __ ...,. .VIARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 9/27/2017 Plumbing Permit Fee(Enter Fixture Fee) $180.00 9/27/2017 Plumbing Plan Review Fees $350.00 9/27/2017 Processing/Technology Fee $25.00 9/27/2017 Water Heater $50.00 Total Due: $605.00 Total Payment: $0.00 Balance Due: $605.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit Information Date 9/20/2017 Permit Number 1664 Project Name Top Cub Aircraft,LLC Applicant Name Flow Control Plumbing Applicant Address 621 State Route 9 NE PMB C2 City,State,Zip Lake Stevens,WA 98258 Contact Paul Rendon Phone 425-512-9495 Email flowcontrolplumbing@comcast.net Permit Type Commercial Plumbing Site Address 17922 59th Drive NE Valuation 0.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 0 Proposed Use New Installation for Industrial Building Assigned To Kristin Foster Property Information Owner Information Parcel#:31052200300100 City of Arlington City of Arlington 18204 59th Drive NE 17922 59th Drive NE Arlington,WA 98223 Contractors Contractor Name Primary Phone Email Contractor Type License License# Contact Flow Control Paul 425-512- 9@comcast.ne llowcontrol lumbin PLUMBING ILabor and FLOWCCP837LE Plumbing,LLC Rendon 9495 p CONTRACTOR Industries Review Date Type Description Target Date Completed Date Assigned To Status 9/20/2017 Commercial Plumbing 9/27/2017 PW Admin Rev In Review /20/2017 Commercial Plumbing 3/27/2017 PW-Sew-Rev In Review 9/20/2017 Commercial Plumbing 9/27/2017 PW-Wat-Rev In Review 9/20/2017 Commercial Plumbing 3/27/2017 Rick Karns In Review Notes Date Note 9/20/2017 Waiting for plans and specs,need valuation. Uploaded Files i Upload File Date File Uploaded B 9/20/2017 4:47:51 PM 1664 Fixture Sgg_s df Foster, Kristin x 9/20/2017 4:47:50 PM 1664 Apptication.pdf Foster,Kristin ( 9/20/2017 4:47:50 PM 1664 Plan.pdf Foster,Kristin x 4`A' COMMERCIAL PLUMBING PERMIT APPLICATION Department of Community&Economic Development City of Arlington - 18204 59th Ave NE -Arlington, WA 98223 - Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF CONSTRUCTION DRAWINGS, AND TWO(2) SETS OF FIXTURE SPECIFICATIONS (CUT SHEETS). CALCULATIONS ARE REQUIRED FOR GREASE INTERCEPTOR IF APPLICABLE. Type of Permit: 0 New Installation '/Addition/Alteration [ Industrial Project Address: 12922 SyZ.4 p, Parcel ID#: Lot#: Subdivision: Project Description: Valuation: �, Owner: TU"o Phone Number: Address: City: State: Zip Code: Contact Person: "V\ �� Phone Number: Cell Phone: E-mail: Address: City: State: Zip Code: Contractor: /!'Gym LI�yJD�/c�/ /,I`�7d/�ti Phone Number: Cell Phone:2 4)6-Z 7Zr 3, �47 Email: Address:6 PilBG2 State:. zip code: Contractor License Number: ,Z 61 Q Expiration Date: l Please indicate number of fixtures: Water Closet Floor Sink Sump Hose Bibb Miscellaneous Lavatory Laundry Tub 2 Washer Water Heater Z Grease Trap Urinal Interceptor Sink . Med Gas Drinking Fountain` Floor Drain Dishwasher Backflow Shower Other 6/16LP Page 2 of 3 46vo COMMERCIAL PLUMBING PERMIT APPLICATION Department of Community&Economic Development City of Arlington • 18204 59th Ave NE•Arlington,WA 98223 • Phone(360)403-3551 WHEN is a PLUMBING PERMIT REQUIRED? The City of Arlington requires a plumbing permit before a plumbing system or fixture is installed, altered, or remodeled. This also includes replacement of a Hot Water Tank. The City of Arlington does not require a permit to stop leaks or clear stoppages, unless the piping being repaired is altered or replaced. PLUMBING PLAN REVIEW IS REQUIRED FOR THE FOLLOWING PROJECTS 1. New Commercial Buildings 2. New Multi-Family Buildings 3. Roof Drains and Overflow Systems 4. Tenant Improvements 5. Installation of Medical Gas Systems 6. Installation of Commercial Kitchen's and Deli's 7. Installation of Grease Traps 8. Installation of Grease Interceptors 9. Installation of Sumps 10. Installation of Cross Connection Backflow Devices SUBMIT TWO (2) COPIES OF THE FOLLOWING FOR PLUMBING PLAN REVIEW: ❑ Plumbing plans or drawings. (Minimum plan size is 18" X 24" scale, '/4" scale for details.) ❑ Provide one set of plumbing drawings maximum size 11" X 17" ❑ Size of sanitary and potable water systems. ❑ Location, type and specifications (cut sheets) of proposed fixtures and equipment. ❑ Riser diagram of waste and vent, potable water and rain water systems, including sizes. ❑ Medical gas piping riser diagram indicating type of gas, storage room and size of piping. ❑ Location and type of all backflow assemblies for each fixture. I hereby certify that I have read and examined this application and know the same to be true and correct and I am authorized to apply for this permit. 6/16LP Page 1 of 3 t COMMERCIAL PLUMBING PERMIT APPLICATION Department of Community&Economic Development City of Arlington • 18204 59th Ave NE•Arlington,WA 98223 • Phone(360)403-3551 PROPOSED BUILDING USE IT New Commercial ❑ Restaurant ❑ Automotive Based ❑ Commercial Addition/Alteration ❑ Office ❑ Machine Shop El Industrial ❑ Medical ❑ Other: CROSS CONNECTION Please check all appliances that are proposed or are permanently connected to the water supply. ❑ Ice Machine ❑ Dialysis Equip. ❑ Air washers ❑ Swimming ❑ Fire Sprinkler Pools ❑ Coffee Steam Sprinkler ❑ Hydrotherapy Equip. ❑ ❑ Hot Tub/Spa ❑ Urn/Espresso Generators w/chemicals ❑ Carbonated Bev. ❑ Dental Equip. ❑ Dye Vats ❑ Aquarium ❑ Lawn Irrigation Fume Hoods ❑ Laboratory Equip. ❑ Pressure ❑ Decorative ❑ Well on Washers Fountain property ❑ Degreasers ❑ Autoclave/Sterilizers ❑ Cooling Towers ❑ Other:_ WASTEWATER DISCHARGE 1. Does the plumbing system currently have a grease interceptor? ❑ Yes No ❑ Don't Know Date grease trap/interceptor was last cleaned (provide service record): 2. Does the plumbing system currently have an oil/water separator? ❑ Yes No ❑ Don't Know 3. Date oil/water separator was last cleaned (provide service record): 4. Is water used in the business process(washing, rinsing, cooling)? ❑ Yes No ❑ Don't Know 5. Does your business require a NPDES permit? ❑ Yes ❑ No ❑ Don't Know I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above-described property will Mb in accordance with the laws, rules and regulation of the State of Washington Applicants Signature Date Print Applicants Name FOR STAFF USE ONLY lw+ 1/ SEP 18 2017 Permit# Ac pled Amount Received Receipt# Date Received 6/16LP Page 3 of 3 9/20/2017 FLOW CONTROL PLUMBING LLC Search L&I —� 1 Z fndi flclp Nty L&I Safety&Health Clalsns&Insurance rAtnrkplace Righte rr des !_icens;ng Washington State Department of " Labor & Industries FLOW CONTROL PLUMBING LLC Owner or tradesperson 621 SR 9 NE PMB C2 Principals LAKE STEVENS,WA 98258 425-512-9495 RENDON,PAUL ANTHONY,MANAGER SNOHOMISH County Doing business as FLOW CONTROL PLUMBING LLC WA UBI No. Business type 604117 480 Limited Liability Company License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties PLUMBING License no. FLOWCCP837LE Effective—expiration 06/05/2017—06/05/2019 Bond Ironshore Indemnity Inc $6,000.00 Bond account no. SUR40005751 Received by L&I Effective date 06/05/2017 05/31/2017 Expiration date Until Canceled Insurance Ohio Security Ins Co $1,000,000.00 Policy no. BLS57963962 Received by L&I Effective date 06/05/2017 04/17/2017 Expiration date 04/17/2018 Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. HOp us improve hftps://secure.Ini.wa.gov/verify/Detail.aspx?UBI=604117480&LIC=FLOWCCP837LE&SAW= 1/2 �� I ,r 9/20/2017 FLOW CONTROL PLUMBING LLC Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 588,170-01 Doing business as FLOW CONTROL PLUMBING LLC Estimated workers reported Quarter 2 of Year 2017"Less than 1 Workers" L&I account contact T5/JAVIER PAREDES(360)902-4639-Email:PAJB235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. hftps://secure.Ini.wa.gov/verify/Detail.aspx?UBI=604117480&LIC=FLOWCCP837LE&SAW= 2/2 r- � �� � 3. , I W CADET° PROT" RIGHT HEIGHT° ELONGATED TOILET ® BARRIER FREE VITREOUS CHINA CADET®PRO"" RIGHT HEIGHT® ELONGATED TOILET ❑ 215AA.004 • Features the Cadet®Flushing System •Vitreous china •Low consumption (6.0 Lpf/1.6 gpf)toilet •Trade exclusive tank • PowerWashO rim scrubs bowl with each flush — - • Robust metal trip lever& metal shank fill valve • Includes EZ-Install Tools w/color match bowl caps • EverClean®surface included •3" flush valve • Fully-glazed 2-1/8" trapway • 16-1/2" rim height for accessible applications • 12" (305mm) rough-in •Generous 9" x 8"water surface area • Chrome finish trip lever is supplied • 1,000g MaP Score**at 1.6 gpf •5 year warranty FINISHED WALL 3517A.101 Right Height°Elongated Bowl 8-7/8" (767mm) t7.3,6 4188A.004 Tank ( � (226mm) 44tmrn)— Nominal Dimensions: 767 x 441 x 771mm (30-1/8" x 17-3/8" x 30-3/8") E (470 m) 30.3r8' GL OF SEAT POST HOLES (771mm) �140mm(5-1/2'CENTERS) Fixture only, seat and supply sold separately SUPPLY Alternative Tank Configuration Available: E RE ❑ 4188A.054 Tank complete with Aquaguard Liner 'S.tn i 358mm, ❑ 4188A.064 Tank complete with tank cover (4191.1m) (254mm) locking device ❑ 4188A.074 Tank complete with Aquaguard Liner 1 I and tank cover locking device 7.7/16' r 13-5/8' FINISHED) 6 4188A.005 Tan complete with trip lever located (189mmj —(347mm) FLOOR (152mm) 12° I\C/L OF OUTLET 9-5/8 on right side (305mm) (244mm)~ ❑ 4188A.065 Tank complete with tank cover locking device and trip lever located on right side NOTES: THIS TOILET IS DESIGNED TO ROUGH-IN AT A MINIMUM DIMENSION OF 305MM(12")FROM FINISHED WALL TO C/L OF OUTLET. Compliance Certifications- SUPPLY NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED SEPARATELY Meets or Exceeds the Following Specifications: *DIMENSION SHOWN FOR LOCATION OF SUPPLY IS SUGGESTED, IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of •ASME A112.19.2-2008/CSA B45.1-08 for Vitreous tolerances established by ANSI Standard A112.19.2. China Fixtures These measurements are subject to change or cancellation.No responsibility is assumed for use of superseded or voided pages. Maximum Performance(MaP)testing performed by ® MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND IAPMO R&T Lab.MaP Report conducted by Veritec ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE Consulting, Inc.and Koeller and Company. BUILDING FACILITIES-CHECK LOCAL CODES. To Be Specified: ❑ Color:❑White ❑Bone ❑Linen ❑Black ❑ Seat:#5321.110 EverCleanO Elongated Seat with Slow Close Snap-Off Hinges ❑ Supply with stop: f7� Cadet K188 ©2013 AS America Inc. Rev.5/13 ti LUCERNE TM WALL-HUNG LAVATORY BARRIER FREE VITREOUS CHINA LUCERNEI'm WALL-HUNG LAVATORY • Wall-hung sink • Vitreous china • Front overflow • D-shaped bowl • Self-draining deck area with contoured back and side splash shields -o Y • Faucet ledge • Compliant with Texas accessibility standard (TAS) for children age group 13 and up Faucet holes on 203mm(8")centers(Illus.): �. ❑ 0356.028 For exposed bracket support Shown with 4801.862 Amarilis Heritage faucet with Triune Cross handles (not included) ❑ 0356.015 For wall hanger (included)or concealed arms support ❑ 0356.915 For wall hanger(included) or 0356.028 concealed arms support •Less overflow Faucet holes on 102mm(4")centers: 0355.027 For exposed bracket support 0355.012 For wall hanger (included) or concealed arms support ❑ 0355.912 For wall hanger(included) or concealed arms support ` • Less overflow Single center faucet hole(111us.): ❑ 0356.041 For exposed bracket support Shown with 1340.000 metering faucet (not included) ❑ 0356.421 For wall hanger(included) or > concealed arms support ❑ 0356.921 For wall hanger(included) or concealed arms support •Less overflow 0356.041 ❑ 0356.439 For wall hanger(included) or concealed arms support SEE FOLLOWING PAGES FOR ROUGHING-IN DIMENSIONS •Single faucet hole on right ❑ 0356.066 For exposed bracket support •Single faucet hole on right To Be Specified: ❑ Color: ❑White Nominal Dimensions: ❑ Faucet*: 521 x 464mm ❑ Faucet Finish: (20-1/2"x 18-1/4") ❑ Supplies: Bowl sizes: ❑ 1-1/4"Trap: 381mm (15") wide ❑ Nipple: 254mm (10")front to back ❑ Bracket Support(by others): 165mm (6-1/2") deep ❑ Concealed Arms Support(by others): Compliance Certifications- Meets or Exceeds the Following Specifications: •See faucet section for additional models available • ASME A112.19.2/CSA 1345.1 for Vitreous China Fixtures ® MEETS THE AMERICANS WITH DISABILITIES ACT GUIDE- LINES AND ANSI All 17.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES-CHECK LOCAL CODES. Top of front rim mounted 664mm(34")from finished floor. M37 02016 AS America Inc. spec_0355-0356 Lucerne WallHung Lays Rev.A 8/16 I LUCERNE TM WALL-HUNG LAVATORY BARRIER FREE VITREOUS CHINA ® 0356.028 8"CTRS FOR EXPOSED BRACKET SUPPORT 0355.027 4"CTRS FOR EXPOSED BRACKET SUPPORT 0356.015 8"CTRS FOR WALL HANGER �-0355.012 411 CTRS FOR WALL HANGER OR OR CONCEALED ARMS CONCEALED ARMS 0356.915 LESS OVERFLOW 0355.912 LESS OVERFLOW 1 \02mm Bfimm 1 102mrti Bfimm FINISHED1 1<'1 (3-3:8') I t3.7/0'1 \ WALL F(N15HE0 14•) `FINISHED 1 20.1mm WALL � 203m WALL 152mm ) \ (0•) / ��\�\/} 152mm I (6•) T I I 9£frn 1D2mm 464mm t52 mm I 203m 152Inm I (4') (18-1/4-) (61 I tfl') (6•) I I I flm ( I (61 25mm (S)25mm, C(5116') (1')DIA, I1'1 UTA ACCESS 1 13m1n ACCESS t HOLES 13mm.--- HOLES FOR n r;•) (1 �.J CO NC.ARMS 521mm FOR �—521mm (2D-1/2') CONC- (20.1/2-) ARMS 4Z5mm 425mm-- (16-3/4') (18-3/4•) 267mm 267mm (10-1/2-) 54mm 17.1l0')DIA. (70 ) Hamm HOLES FOR Hamm (a-tr2') CONCEALED ARMS (a1/;') S4mm(2-1/0')DIA 107mm 44mm 25mm _f I f m HOLES FOR (a.I (1.314 MT m J I I /.- 1 102 m (1.1+d) I „ CONCEALEDARMS . - 1 qz� _ ro (J9i m1 �-- 1---I---a .I I '19mm T__ T 1 •298mm (14re'I (— q �� 30mm lOJ mn,(yg•) I '' 3Bmm� >+ 4: (1-112-) DIA ANCHOR �'266mm) I1 U2)DIA ANCHOR SCREW HOLES �152mm SCREW HOLES t S•9 HANGER I—203mm—.•) 03-710') I—204mm (6'1 S-9 HANGER (6') 27mm X 14mm ♦' ♦' 27mm x 14mm •+- (1-1/16'x WIV)SLOTS / 11-1116 x 5116') m y SUPPLIES) SLOTS / w AS REQUIRED SUPPLIES J E F 707mm(31') AS REOi O W 1-1/4'O.D.WASTE `-1-1l4'O.D.WASTE 85dmm 34 - o OUTLET FOR OUTLET FOR FINISHED ( 1•t/a'O.O.WASTE UTL 1O,WASTE DRAIN PLUG POP-UP DRAIN FLOOR ® ORAIN PLUGLET FOR POP-UP FOR PINIONED POP-UP DRAIN FLUOR 18.1/4' FINISHED 18.1/4 FINISHED (464mm) WALL (464mm) WALL 8"MIN. 8"MIN. 34" (203mm) 34" (203mm) (864mm) (864mm) 27"MIN. 27•%1,1N (686mm) - (6A6mrn) - 6"MAX. 6"MAX. (152mm) (152mm) HARMER FREE 9"MIN. - � 9"MIN. (229mmj BARRIER FREE (224mm) .CLEARANCE II CLEARANCE 11• 11' _� 1 (279mm) (274mm} NOTES: *DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND"P"TRAP ARE SUGGESTED. PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS. FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY. CONCEALED ARM SUPPORT AS REQUIRED TO BE FURNISHED BY OTHERS. IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard Al12,19.2.These measurements are subject to change or cancellation.No responsibility is assumed for use of superseded or voided pages. ❑LAVATORY DESIGNED TO MEET ADA HANDICAPPED GUIDELINES WITH MOUNTING HEIGHT SET AT 864MM(34")ABOVE FINISHED FLOOR. M38 ®2016 AS America Inc PART OF L I X I L spec_0355-0356 Lucerne WallHung Lays Rev.A 8/16 I I I RELIANT® 3 S SINGLE CONTROL LAVATORY FAUCET v MODEL NUMBER: ❑7385.000 Reliant 3 Single Control Centerset Metal Speed Connect®pop-up drain. Metal lever handle. �e ❑7385.003 Reliant 3 Single Control Centerset Indexed metal lever handle. Grid drain. LESS pop-up hole. X7385.004 Reliant 3 Single Control Centerset Indexed metal lever handle. LESS drain &pop-up hole. �J— ❑7385.007 Reliant 3 Single Control Centerset Indexed metal lever handle. LESS drain&pop-up rod. 142 mm I With pop-up hole. kik= ❑7385.008 Reliant 3 Single Control Centerset Indexed metal lever handle.Metal Speed Connect E pop-up drain. 154 mm (6-1/16") 117 mm _I (4-5/8") ANDARD HANDLE 143 mm 11;(4 102 mm(3-7/8") (4)mm--—.J 66 mm I 1 I 30 mmJ f 32 mm (1-114") (1-1/4")DIA. 498 mm I63 mm MOUNTING (19-5/8") (2-1/2") HOLE PRODUCT FEATURES: BRAIDED =`'-' Cast Brass Waterwaywith Flexible Supply Hoses: FLEXIBLE _ pp y SUPPLY HOSES _ Strong and durable.Less potential for leaks. WITH RE Ceramic Disc Valve Cartridge:Assures smooth,precise valve COMPRESSION� 9 CONNECTORS 32 mm OD-- control and a lifetime of drip-free,maintenance-free performance. (1-1/4"OD) Adjustable Hot Limit Safety Stop: Limits the amount of hot GENERAL DESCRIPTION: water allowed to mix with cold.Reduces the risk of accidental scalding. All metal body with choice of metal lever, indexed metal Exclusive Speed Connect Metal Drain: lever handle or optional extra long lever handle. •Fewer parts. Installs in less time. Washerless 47 mm ceramic disc valve cartridge with .No adjustments required-seals the first time,every time. integral hot limit safety stop. Durable cast brass waterway.Braided flexible supply hoses with 3/8"compression .Flexible stainless steel cable-installs effortlessly in tight spaces. connections.20" (500 mm) long flexible stainless steel drain Lead Free: Faucet contains<0.25%total lead content by cable is pre-assembled to faucet body. Metal Speed weighted average. Connect®drain body(on 7385.000&7385.008)with 1-1/4" Simple One-Person Installation: Faucet drops in from top. (32 mm)tail piece. 1.2 gpm/4.5 L/min.maximum flow rate. Quick spin nuts secure faucet in place. SUGGESTED SPECIFICATION Single control lavatory fitting shall feature an all metal body with metal lever handle.Shall feature a cast brass waterway with flexible hose connections.Shall also feature a washerless ceramic disc valve cartridge with integral hot limit safety stop. Shall also feature a metal drain body with stainless steel cable actuation.Fitting shall be American Standard Model#7385. 0 2017 AS America,Inc. Revised 5/17 I I I I RELIANT® 3 SINGLE CONTROL LAVATORY FAUCET CODES AND STANDARDS 1.4 FLOW RATE' These products meet or exceed the following 1.2 codes and standards: a 1•0 � o.a ANSI A117.1 a 0,6 ASME A112.18.1 p 0.4 NSF 61/Section 9 and Annex G 0.2 CSA B125.1 0.0 (77 0 20 40 60 80 INLET PRESSURE(PSI) 'Fow rates shown ere for mixed hot and cold. Finish Options Polished PVD Chrome Brushed Product Nickel Number Description 002 295 7385.000 Reliant 3 Single Control Centerset.Metal lever handle. Metal Speed Connect®pop-up drain. 7385.003 Reliant 3 Single Control Centerset.Indexed(Red/Blue)metal lever handle. Grid drain.LESS pop-up hole. 7385.004 Reliant 3 Single Control Centerset. Indexed(Red/Blue)metal lever handle. LESS drain. LESS pop-up hole. 7385.007 Reliant 3 Single Control Centerset. Indexed(Red/Blue)metal lever handle. LESS drain and pop-up rod.With pop-up hole. 7385.008 Reliant 3 Single Control Centerset.Indexed(Red/Blue)metal lever handle. Metal Speed Connect pop-up drain. Meets the American Disabilities Act� Guidelines and ANSI A117.1 Requirements 7385.000 7385.003 7385.004 7385.007 7385.008, for the physically challenged. JP "PCA—Pressure Compensating rlwl `!►� "`To modify a product,add suffix after the 4th digit L:• c�- •Indexed(Red/Blue) (ex.2064F05101.002) •Metal Lever Handle •Indexed(Red Bh o) •Indexed(Red'B!uo) metal lever handle •Indoxeo(Red elue) —Modified product models are NOT WaterSense •speed connect" metal lever handle metal lever handle •LESS drain, metal love,handle metal drain •LESS drain, •LESS drain, LESS pop-up rod •Speed Connect certified. LESS pop-up hale LESS pop-up hole •With pop-up hole metal drain AERATOR • e • € LESS pop-up drain; c c with hole and pop-up rod _XPR —XPR N =c '� Extra long handle _LH _.LH —LH —LH —LH 0.5 gpm(1.9 Lpm)PCA*Spray _F05 F05 _F05 1705 _F05 Vandal-Resistant V05 V05 V05 V05 V05 0.5 gpm/1.9 Umin.PCA Aerator — — — —. Vandal-Resistant F10 F10 F10 F10 F10 to 1.0 gpm(3.8 Umin.)PCA Aerator — — — — — ° Vandal-Resistant 0 1.0 gpm(3.8 Umin.)PCA Aerator —V10 _V10 _V10 —V10 —V10 P Vandal-Resistant V12 V12 V12 V12 V72 1.2 gpm(4.5 Umin.)PCA Aerator — — — — — 0 v Vandal-Resistant 0 1.5 gpm/5.7 Umin.PCA*Aerator _V15 —V15 _V15 _V15 —V15 a Non-Aerated Laminar 1.5 gpm/5.7 Umin.PCA Flow outlet _1_15 —L15 _1_15 _L15 _L15 Non-Aerated Vandal-Resistant V05 V05 See 7382.050 V05 V05 0.5 gpm/1.9 Umin.PCA Spray — — — — 2.2 gpm/8.3 Umin Aerator F22 F22 F22 1722 F22 0 2017 AS America,Inc. Revised 5/17 ELK.4Y Wall Mount Water Cooler SPEC/FICA TONS Models EZ(S)4, EZ(S)8 and EZ(S)D PRODUCT SPECIFICATION RATED FOR INDOOR USE ONLY Self-contained,wall mount electric water cooler.Refrigerated EZ(S)8 models offer a chilling capacity of 8 gallons per hour of 50•F drinking water, based upon 80'F inlet water and 90"F ambient. Models EZ(S)D are non-refrigerated and shall deliver non-chilled drinking water. Unit shall meet ADA guidelines. � • '?` ° USA Unit shall be lead-free design which is certified to NSF/ANSI 61 and 372 �>< and meets Federal and State low-lead requirements.Unit shall be certified to .. UL399 and CAN/CSA 22.2 No.120. - Models EZS4 AND EZS8 have self-closing Easy-Touch pushbar controls on - front&sides. Models EZ4 AND EZ8 have self-closing Easy-Touch pushbar controls on front only. "« x X'!�=';'� • i1 Models EZ(S)D are non-refrigerated.Requires outlet for power cord. STANDARD FEATURES • Easy-Touch pushbar activation • Extra deep basin minimizes splashing;with integral drain • Available with Flexi-GuardO Safety bubbler or Vandal-resistant'bubbler ('includes"VR"code in model no.see chart below) • Valve with built-in flow regulator to provide constant stream from 20 to 105 psi water pressure • Finish options:Impact-resistant vinyl coating or stainless steel wrapper • Rated for Indoor use COOLING SYSTEM (Models EZ(S)(VR)8*(F) and EZ(S)4*(F)only) CONSTRUCTION • Compressor:Hermetically-sealed,reciprocating type,single phase. Stainless Steel basin with integral drain Sealed-in lifetime lubrication. Galvanized structural steel cooler chassis provides structural integrity • Condenser:Fan cooled,copper tube with aluminum fins.Fan motor is Cooler cabinet available as Light Gray Granite Vinyl Clad Steel or permanently lubricated. Stainless Steel(additional cost)construction • Cooling Unit:Combination tube-tank type.Self-cleaning.Continuous Exclusive Flexi-Guarde Safety bubbler(option)utilizes an infused copper tubing with stainless steel tank.Fully insulated with EPS foam anti-microbial pliable polyester elastomer to prevent accidental mouth that meets UL requirements for self-extinguishing material. injuries.Flexes on impact. • Refrigerant Control: Refrigerant R134a is controlled by accurately Vandal-resistant'bubbler(option)is one-piece,heavy duty construction calibrated capillary tube. Warranty: 5 year limited warranty on the unit's refrigeration system. • Temperature Control: Easily accessible enclosed adjustable thermostat Electrical components and water system are warranted for 12 months from is factory preset.Requires no adjustment other than for altitude date of installation or 18 months from factory shipment,whichever date falls requirements. first. Glass Filler e CAPACITIES CHART (option)(F) US G O tl.: ,•i available L at extra cost `USA Voltage/ Chillin ** F.L. Rated Approx. Requires UL399 and NSF/ANSI Model 9 9 Ship Factory prep to CAN/CSA 22.2 ADA Hertz Capacity Amps Watts wt. receive glass filler No.120 COMPLIANT 6Cert Cert1 and ified Certified t EZ(S)4*(F) 115V/60Hz 4 GPH 2.0 370 50 lbs. YES t EZ(S)8*(F) 115V/60Hz 8 GPH 4.0 370 51 lbs. YES t EZS8'(F)2JO 220V/5OHz 6.7 GPH 2.0 370 51 lbs. YES ++ t EZS8*(F)3JO 220V/60Hz 8 GPH 2.0 370 51 lbs. YES ++ t EZSD*(F) 115V/60Hz - - - 25 lbs. YES t EZD*(F) 115V/60 Hz - - - 25 lbs. YES EZ4* 115V/60Hz 4 GPH 2.0 370 50 lbs. NO EZ8L3JO 220V/60Hz 8 GPH 1 2.0 1 370 51 lbs. NO ++ EZSVRB* 115V/6OHz 8 GPH 4.0 370 51 lbs. NO EZSVRD* 115V/60Hz I - I - 25 lbs. NO 'Color code of(L)Light Gray Granite,or(S)Stainless Steel cooler wrapper. **Based on 60•F inlet water&90•F ambient air temp for 50•F chilled drinking water. ++Complies;not third party certified. This specification describes an Elkay product with design,quality and functional t Glass filler available at extra cost,add code(F).Requires factory preparation to receive benefits to the user.When making a comparison of other producer's offerings, glass filler. Note:Vandal-Resistant bubbler models do not have glass filler option. be certain these features are not overlooked. In keeping with our policy of continuing product improvement, 2222 Camden Court Elkay reserves the right to change specification without notice. Oak Brook,IL 60523 ©2016 Elkay Please visit elkay.com for the most current version. 630-572-3192 SPEC12-23 (01/2016) elkay.com r I I I e I Wall Mount Water Cooler L.1< Models EZ(S)4, EZ(S)8 and EZ(S)D ROUGH-IN DIMENSIONS RATED FOR INDOOR USE ONLY Open space rough-in design permits new installation or replacement of existing fountains and coolers with this Elkay cooler when rough-in is within the outline shown. IMPORTANT! INSTALLER PLEASE NOTE: NOTICE This water cooler has been designed and built to provide water to the user which has This water cooler must be connected to the water supply using a dielectric coupling. not been altered by materials in the cooler waterways. The cooler is furnished with a non-metallic strainer which meets this requirement. The drain trap,which is provided by the installer,should also be plastic to completely The grounding of electrical equipment such as telephone, computers, etc to water isolate the cooler from the building plumbing system. lines is a common procedure. This grounding may be in the building or occur away from the building. This grounding can cause electrical feedback into a water cooler creating an electrolysis which creates a metallic taste or causes an increase in the metal content of the water. This condition is avoidable by installing the cooler using the proper materials as shown below. Model shown with Flexi-Guard'bubbler. FRONT VIEW SIDE VIEW 18 3/8" 191, 467mm 484mm 6 3/8" 6 3/8" 7mm If'1 162mm 162mm HANGER BRACKET 2" 51mm E r 1 L E 32718" r� 835mm ORIFICE 81/16" Ll! 205mm L, I A HEIGHT / — -, 31 5/I6" 796mm RIM C HEIGHT 2II 13/I6" — — 732mm 27- 21 718" 1 686mm 556mm F _ 2„ ADA 19" 51mm REQUIREMENT 5 7/8" 483mm 3 7/8" 150mm 98mm 1315116" 1 3" 17 7/16" 5 3/4" 354mm 12 Il2` 77mm 443mm 146mm 318rrm 2" 7" 7" 51mm 178mm 178mm LL, FNJISHED FLOOR REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER LEGEND: A=Recommended Water Supply location.Shut-off Valve(not furnished)to accept 3/8"O.D.unplated copper tube.Up to 3"(76mm)maximum out from wall. Job Name: B=Recommended Waste Outlet location.To accommodate 1-1/4"nominal drain. Model: Qty. Drain stub 2"(51 mm)out from wall. Contact: C=1-1/4"Trap(not furnished). Approval Signature: D=Electrical Supply(3)Wire Recessed Box Duplex Outlet. E=Insure proper ventilation by maintaining 6"(152mm)minimum clearance from cabinet Notes: louvers to wall. F=7/16"(11 mm)Bolt Holes for fastening to wall. NOTE:New Installations Must Use Ground Fault Circuit Interrupter(GFCI) 2222 Camden Court Printed in U.S.A. Oak Brook,IL 60523 ©2016 Elkay 630-572-3192 elkay.com � � L 1 i i A GV J=„8/i:3lv35 SNtlld NINtlZZ3W ONd 8001i ONf1089 Nmd aoo-IA dWas 11OG ® G d3S Q OUl :Ag uM6JpT30HAO.£ a/� MOO m Ia�a �s W C o o „0•,ZT b o 3DNVa1N3 N N r N M a IIX3 11X o n D A� �,y} ` 1 1�{ v D NNISAlllllfl �1`�! ((1� �L1�'V 11y�`� 1/U _ o - - 1N3do V V I !!! Ol N3d0 HOIL03dSNI ONicnin9 „o,oi o- >aFu.As a3noaddv ss3rlNn 03zlHOHMV SWNVHo ON ES171 V'a :#od C33AOUddd o $ - g � ;, 1N31NIHVd34 ONlaltn9 \1/ o o NOIDNI'I'� 3O )MO �• Nr � °�' A C � cm � p �. °' bo maA 1 y CL NNIS Almingr , m w 01 �P W 3,- 9NlanndjnNeW74 aooij aNnoag — a, u, 1 LD x N ��� N 0 W � hl N HOOIJ aNOJ3S „3NINVZZ3W„ rn D 4 n o �• w _ w � w O In m b � r- o * sW O D D C D l�� INzv_ 2 o w m Z N w 0-,Oi -in c V1 c 03 r x W r u+ - Ln 00 A 6 o v m o IIX3 1 X3 z 1 'V V „O-,ODZ o ^' o c ANO:)lV9 31VAlad 0 0 —� d Date: 03/19/2026 Permit#: 1664 Permit Date: 09/20/2017 Review Date: 09/20/2017 Permit Type: COMMERCIAL PLUMBING Review Type: COMMERCIAL PLUMBING Target Date: 09/27/2017 Scheduled Time: 00:00 Completed Date: 09/27/2017 Description: RPBA required can be installed inside the building before any branched connections. GUS Review Status: Assigned To: PW-WAT REV Time In: 00:00 Time Out: 00:00 Hours: 0.0 Property Information Parcel#: 31052200300100 City of Arlington City of Arlington 18204 59th Drive NE 17922 59th Drive NE Arlington,WA 98223 Zoning: Lot: Block: Date: 03/19/2026 Permit#: 1664 Permit Date: 09/20/2017 Review Date: 09/20/2017 Permit Type: COMMERCIAL PLUMBING Review Type: COMMERCIAL PLUMBING Target Date: 09/27/2017 Scheduled Time: 00:00 Completed Date: 09/21/2017 Description: Approved with red lines Review Status: Assigned To: z.Rick Karns Time In: 00:00 Time Out: 00:00 Hours: 0.0 Property Information Parcel#: 31052200300100 City of Arlington City of Arlington 18204 59th Drive NE 17922 59th Drive NE Arlington,WA 98223 Zoning: Lot: Block: Permit#: 1664 Permit Date: 09/20/17 Permit Type: COMMERCIAL PLUMBING Project Name: Top Cub Aircraft, LLC Applicant Name: Flow Control Plumbing Applicant Address: 621 State Route 9 NE PMB C2 Applicant, City, State, Zip: Lake Stevens, WA 98258 Contact: Paul Rendon Phone: 425-512-9495 Email: flowcontrolplumbing@comcast.net Scope of Work: New Installation for Industrial Building Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 09/27/2017 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 31052200300100 17922 59th Drive NE City of Arlington Contractors Contractor Primary Contact Phone Address Contractor Type License License# Flow Control Plumbing, Paul Rendon 425-512-9495 9010 Market PI PLUMBING UBI 604 117 480 LLC CONTRACTOR Flow Control Plumbing, Paul Rendon 425-512-9495 9010 Market P1 PLUMBING Labor and FLOWCCP784CW LLC CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 06/13/2019 C04.PLUMBING AM 06/13/2019 BUILDING Completed GROUNDWORK Plan Reviews Date Review Type Description Assigned To Review Status 09/20/2017 COMMERCIAL No comments,LT PW-ADMIN-GIS PLUMBING 09/20/2017 COMMERCIAL No comments.FR PW-SEW-REV PLUMBING COMMERCIAL RPBA required can be installed inside the building before 09/20/2017 PLUMBING any branched connections.GUS PW-WAT-REV 09/20/2017 COMMERCIAL Approved with red lines z.Rick Karns PLUMBING Fees Fee Description Notes Amount Mechanical Commercial Permit Table 4-7;Per Unit 15 @$12 $180.00 Plumbing Plan Review Fees $350.00 Processing/Technology $25.00 Water Heater(Tank) 2 @$25 $50.00 Total $605.00 Attached Letters Date Letter Description 09/27/2017 Building Permit 09/27/2017 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 09/27/2017 Paul Rendon 66602225 cc $605.00 Outstanding Balance $0.00 Notes Date Note Created By: 02/20/2019 Expired.Filed in address files.No final was done. Raelynn Jones 09/20/2017 Waiting for plans and specs,need valuation. Kristin Foster Uploaded Files Date File Name 09/30/2021 9798630-1664 IC 6.13.2019.pdf 09/27/2017 2655318-1664 Issued Permit.pdf 09/20/2017 2638504-1664 Fixture Specs.pdf 09/20/2017 2638502-1664 Plan.pdf 09/20/2017 2638503-1664 Application.pdf