Loading...
HomeMy WebLinkAbout17823 31st Dr Ne_BLD1546_2026 (174 Z- SNOHOMISH HEALTH DISTRICT WWW.SNOHD.ORG Environmental Health Division August 18, 2017 006213 000 07500 Property Tax Account Number Nick & Maria Median David & Maria Harmon 17823 31st Dr NE Arlington, WA 98223 Subject: Snohomish Health District Clearance for a Building or Mobile Home Permit Site Address: 17823 31 It Drive, Arlington Dear Sir/Madam: This is to inform you that the Snohomish Health District (Health District) Water and Wastewater Section has received an application for a Building or Mobile Home Permit Clearance concerning your proposed development project. The Health District reviews construction permit requests to determine if the proposed project is in compliance with applicable onsite sewage disposal regulations, and if required by the Building Department, compliance with rules regarding an adequate water supply. The Health District has determined that your proposed project does not under present conditions meet the minimum requirements of Snohomish Health District Sanitary Code, Chapter 8.1 (WAC 246-272A) and Snohomish Health District Sanitary Code, Chapter 8.1.2 for a building clearance for the following reason(s): 1. The submitted construction clearance site plan is not consistent with the septic system as-built drawing on record with the Snohomish Health District. SHD records indicate that the area listed as "reserve area" on the construction clearance is indeed the existing primary drainfield. The area listed as "existing drainfield" on the construction clearance is the proposed reserve drainfield documented on an updated as-built drawing dated 3/15/1995. This as-built drawing describes that the original system was not altered or replaced at time of as-built drawing. 2. The location of the proposed shop encroaches on the primary drainfield on record. In addition, areas of the primary drainfield and the designated reserve drainfield have been subject to cover by impervious material and vehicle parking. In accordance with WAC 246-272A-0270, the OSS owner is responsible for protecting the onsite sewage system area and reserve area from cover by structures or impervious material, soil compaction, for example by vehicular traffic, and damage by soil removal and grade alteration. See copy of the septic as-built drawing depicting the location of the proposed shop scaled at V=20'. 3. Contact a licensed onsite sewage system designer or professional engineer to evaluate the property, and address the issues listed above. 3020 Rucker Avenue, Suite 104 0 Everett, WA 98201-3900 ■ tel: 425.339.5250 v fax: 425.339.5254 ALLPNA5E DRAIIVFIC-Lt) DE 5A1 ZZ.6-06 - Bq-'b NE GRANITE FALCS, WA CoNGRETE c3�o> �91-s y�� 9EZsz ° SLAB ��OFaSED RESErZVE pREl9 % 3-1s-4s sLgLE: zo, wR. IJ►uc rvsbWA TAX &)o. �213-ooa-o�S-000O �zv.00� rill 1 f F-r-1 Sh'f� �N/N Gr 7ll 6 1, CCiN C KE-IC C1 Su9H JFREVIOi 52 DRIVEWAY N SL3 D>z��Iw�� D?wlNr-Icw DastGNER' t-wY D TANNER 2-AJ sT7�u_E R R MY T/L.LET co v-L3-G9 RESERUC ReQkAjREAAEj�TS yso /oo l Zo �ncUn,be� J>���{eJc�l`h'eG (ZeSer,Ie S-�O 4� TUTTt L- oR 2-8 S LI�J E,q� yEcT J7eENCtl C At>b 7al, 5Ela/7C, T.9�lJK G`1Y. RESIDENTIAL PERMIT APPLICATION Department of Community & Economic Development O' City of Arlington• 18204 59th Ave NE •Arlington, WA 98223 - Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE, ADDITION, HECK, OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BYTWO(2)SETS OF CONSTRUCTION DRAWINGS AND TWO SETS OF STRUCTURAL CALCULATIONS. THE APPLICATION MUST ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS. THE ZONING VERIFICATION MAY BE SUBMITTED PRIOR. Project Address: 17823 31st Dr NE, Arlington, WA 98223 Plat: ❑ Single-family ❑ Duplex Cl Townhouse ❑ Addition 1�3 Accessory structure Proposed Area: 1" Floor: 21d Floor: Garage: 484sf Total SF: 484sf Describe Proposal (include cross street): Construct detached, post-frame, workshop, shell only, 22 ' x 22 ' with 8 ' eave height. Existing gravel access off 31st Dr. NE, cross street 179th St NE. Valuation: $17, 962 Owner. Nick and Maria Medina/ P°&J(p vOPdZ4Pr OdEPMa&1 Address: 17823 31st Dr. NE City. Arlington State: WA Zip Code: 98223 Phone: 425-876-5369 Email: Applicant, Theresa @ Town & Country Post Frame Bldgs Address: 16521 Hwy 99 #C City: Lynnwood Mate: WA Zip Code: 98037 Phone: 425-743-1555 Email: permits@permabilt.com Contractor: Town & Country Post Frame Bldgs Address: 16521 Hwy 99 #C City: Lynnwood State: WA Zip Code. 98037 Phone: 425-743-1555 Email: permits@permabilt.com Contact Person: Theresa License Number: TOWNCPF099LT Expiration: 6/30/19 6i16LP Page 1 of 3 V RESIDENTIAL PERMIT APPLICATION • • Department of Community & Economic Development City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 Plumbing Section (continue filling out if plumbing is involved) (Check all that apply and indicate the number of fixtures proposed) n/a - if plumbing, owner to obtain Bath/Shower Combo (4.0) x ❑ Sink (1.5) x ❑ Shower (2.0) x ❑ Lavatory (1.0) x U Clothes Washer (4.0) x ❑ Water Closet(2.5) x ❑ Dishwasher (1.5) x ❑ Water Heater x ❑ Hose Bibb(2.5) x Water Heater Model # FJ Other (list) x Plumbing Section Continued Proposed Water Piping Size: Proposed DWV Material: Proposed Piping Material: Proposed DWV Size: • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) 6/16LP age 2 of 3 INV -I .OF RESIDENTIAL PERMIT APPLICATION .y > Department of Community & Economic Development City of Arlington - 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 Mechanical Section (continue filling out if mechanical equipment is involved) Select proposed appliances: n/a U Furnace(80+) Model# AFUE Heat Pump Model# SEER HSPE AC Unit Model# SEER La Type II Hood ❑ Commercial Choking Appliance U Hydronic Piping Boiler Solid-Fuel Appliance U PV System U Fireplace Insert Outdoor BBQ Ft Storage Tank 0' Freestanding Stove U Gas Piping U other Gas Piping Information Not Applicable: U Pipe Material: Pipe Size: Total BTU's of all Appliances: Distance from Meter to Furthest Appliance:_ • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper combustion air and venting required for all appliances • A shut-off is required within 6 feet of all appliances Applicant Signature: � Date: 6-19-17 Print Applicants Name: J 6/16LP Page 3 of 3 RECEIVED JUL 112017 DETAIL7/2 METAL ROOFING PER "w a (OR) DETAIL (29 GAUGE) ST. NOTE #4, SHEET 3, m cJi o W/ NO POST. GENERAL NOTES m DETAIL 2 — 1. BUILDING MAY BE CONSTRUCTED OF ANY SIDEWALL LENGTH AND SPAN MEETING THE REQUIREMENTS OF THESE BASIC PLANS WHERE RATIO OF LENGTH TO SPAN c o,;y o IS EQUAL TO OR LESS THAN 3. 12 ,o � o_ 7 (MAXIMUM) 2. SPECIFIC BUILDING DIMENSIONS, WALL OPENINGS AND ACCESSORIES ARE INDICATED ON PERMABILT BUILDING DESIGN SHEET. (ATTACHED) DETAIL 9/2 3. BUILDING MAY BE A COMBINATION OF CLEARSPAN AND GRID SYSTEM SIMILAR TO PLAN. a 4. CONSTRUCTION OPTIONS WHERE SHOWN ARE AT THE BUILDER'S DISCRETION. Z m OPTIONAL EAVE c 0 OVERHANG PER INTERIOR RAFTER u P LIN PER DETAILS o �1 DETAIL 2/2. 2 & 4/2 AND PER SCHEDULE G. C CHEDULE D. POST PER— SCHEDULE A.71 7 z oCRuNEOUILL PGE A GIRTS PER DETAIL 12/2. w 2 I 1 I I I I RAKE BEAN PCR INT OR POST PER = N A 0 x SCHEDULE f PER S EDULE K. w suolswaU I II I ML 5 (SCHEDULE v Fi ATT ENDWALL Iv/Ln m ERH+ac) (NOTE: POST MAY dv I ( II II 29 GA. METAL WALL NOT BE REQ'D AT II CLADDING PER NOTE 2. rDETAIL CENTER OF BLDG.) z #4, SHEET #3. 13/ � (OPTIONAL CLADDING FLOOR p r I 1 II x II PER NOTE #11, / D_ m ENDWALL POSE SHEET #3.) 1 tr Z PER SCHEDULE B. / \O z En a a ¢ w INTERIOR OTINGS'ONQ~ ENDWALL POST a I t II wa 11 ✓! /PPER I I I I� I I I I I I I z N PER SCHEDULE w III IIII PER SCHED P I I I I I � Z W AND DETAIL 1 N II III IIIIIIIQ6 L1 LI Li ii L1 LJ OE HC,0 POST SPACING ST SPACING INTERIOR POST �.J(�� PER SCHEDULE K. U X ( I I I I I 1jr ' .�•J 4�� rf� SPAN • Y TYPICAL SECTION THRU GRID SYSTEM �s o O y J aAll Ti t U w < I, > 199W 4 � c e + 14J DETAIL 8/2 3:o BLDG. LINE X �}p,,rr pp '�'• (— Pose(ivp j BAY SIZE BAY SIZE BAY SIZE ON ALL METAL ROOFING PER (14- MAX.) (14' MAX.) (14' MAX.) NOTE #4, SHEET 12 R = SIDEWALL LENGTH lv f, 3. (29 GAUGE) —1 7 (MAXIMUM) I (FOR MAXIMUM SEE NOTE 1) PURLIN PER DETAILS ` Fr PLAN 3/2 4/2 AND SCHEDULE D. I 2x6 BETWEEN OPTI VE .j ENDWALL SAVE GIRT OVER PER J POSTS w/(4) 12d TO 2x4 BRACE D AIL 2-12d (iYP�) 12d AT t6"o.a AND (a) 12d TOE PER SSCHEDULE SUPPORT BLOCK AND K W/BRACBNG OPERRDETAIL PURUN EAVE GIRT TO 2x6. NAIL AT POSTS. 2-124 10£HNL (3)12d. EAVE DETAIL 1/2. 1/1 AND/OR 2/1 i . EACH SIDE -0 GIRT TO BRACE. II o POST PER SCHEDULE A t_ BRACELINLIN SIMPSON CS16 L7 m STRAP BENT AT 42x4 BRACE R EAVE GIRT w/(5) _ 12d x 1 1/2 (1 NAIL AT EAVE ENDWALL POST 29 GA. METAL WALL SY1a GIRT) PER PLAN CLADDING PER NOTE #4, GIRTS PER DETAIL 12/2. G (IF OCCURS) BAY SHEET 3. (OPTIONAL CLADDING PER NOTE #11, SHEET 3.) Z PURLIN PUR IH DETAIL. 13/2 C FLOOR � O N 0 '1 3-12d @ LAP Z II SPLICE (TYP.) ,`��• ' 2x6 HF#2 BRACE I I I I I Z Q 1 AT LOCATIONS li NOTED ON TRUSS I I c II 6 FOOTINGS PER SCHEDULE H III C O DRAWING BRACE CONTINUOUS LI AND DETAIL 16/2. u �\ DBL TRUSS (OR SINGLE BRACE APPLIED AT SHEET INDEX \ 5.0' TRUSS AT END BAYS IF LOCATIONS NOTED ON 6 Q TRUSS DRAWING. OCCURS) PER TRUSS SPAN=22'0" SHEETS IN = 0 [2-121"T.E NAIL MANUFACTURER ATTACH TO TRUSS THIS PLAN SET: EA SIDE BOTTOM CHORD w/ 2-12d TOE-NAIL AT 1/3 ,1a13 �,� EACH CHORD. 2/3 / I \TYP. TRUSS BRACING ® SOT. CHORD w/ ONE TRUSSED BAY 2 TYP. TRUSS BRACING � BOTTOM CHORD w MULTIPLE TRUSSED BAYS. x TYPICAL SECTION THRU CLEARSPAN 3oi3 � 1 1 1 0 (3) NOTE: 0.1"31"D x F i� o 3-1 4 NAILS GI T/TO BLOCK o c c v o �rn') c a x ATTACH WALL PANEL w/#10 x 1-1/2" SYM. AB'T BLOCK FOR STRAP TOP ((AND BOTTOM) o o v a v SELF-TAPPING SCREWS AT 9"oc OF WIND OPENING. e ALONG VERTICAL EDGE OF OPENING BLOCK FOR AND BLOCKS STRAP y� GIRT 24" LONG E N N NOTE 10 . —STRAP SWe tOd OxN 1-1/2 L—BLOCK AT EACH END (TYPICAL, ALL o —GIRT CORNERS.) a L—BLOCK BETWEEN W/ 0.1310 x L—GIRTS ,3-1/4 NAILS AT 4"o.c. (TYP.) cuclwaa GIRT 24" LONG STRAP.pER NOTE 10 ON A��a END 1-1/2 w. (TYPICAL.)ALL _'�v ,� 5 _ Z U) ORNER C G1ST —BLOCK fo �1 LLI GIRT J r21 19959 /, b NOTE: __ A)LL) CONNECTIONS 1'D BE BLOCK FOR STRAP �� `�„ ._ .✓ `a <S VAX- U3N.0.1AT ALL NTER ECTINGS 01'VAL g:+� t� NAIL ABUTTING MEMBERS. �n AND 1t�AIL L3 BLg/CjCS NAIL AT AT 12"o.a / 'O j a i-J o WINDOW CORNER DETAIL 0.13, 0 x 3-1 4 NAILS AT 4"o.c. I o _ 1 a N.T.S. c O .31 v4?. � F4P ,2 v STRAP WINDOW PER DETAIL 1/1a I ' - z II' 36�Q'QlLMh w�QR0 1CD O CD LCD _ N U' . i Z Iox"7�pSar J d I- = U 2MOW--I6 ELAO �neet 3 CKIF PNUL. x D ROOF PANEL SCREWS ROOF PANEL SCREWS FOR PURLIN PER SWPSON ANGLE'A23'EACH SIDE 4-1ptl(}y► NOTE/4. OF POST AND LONG LEG ON 2x6 BLOCK W/ AT EACH I KOUI PURLIN TRUSS FOR R/14. PER LV U N 12d 0 3.O.C. ROOF PANEL SCREWS NOTE 1 FN-J •- t POST. 10d x 1-1 CHORD PURUN PER SCHEDULE D 4-12d AT POST RAW BEAM PER 43 EAVE NT W/ TO LOOKOUT FOR PURUN PER t( PER NAILS, d(TVP3 1P14 NOTE/4. SCHEDULE F STEEL STRAP 2/2 ROOF PANEL Y6 1•-6•LAP I.) LQ O.3 9 w (PER NOTE/10) FOR NOTEPUa LIN PER 2.6 BLOCK 2x6 OIOCK 1•-6'lh MAIN. -q_12d RAKE TO EACH PURLIN m C.n C EACH SIDE OF POST N 2� - WIl Tp FAC 1R45y PANELS p n O YJ J �1 W/10-1 Od NAILS BLOCK OR RAFTf14 W/3-12d. WRLIN BETWEEN 2.6 SCAB 12d NAIL PORLW TO BLOCK WALL PANEL SAVE GIRT '' • PURUN SCR EY•5 FOR GIRT �� / • -12-12d RAKE TO POST. AlAT 6'OC,TO LOOKOUT W��3-12d (fi-12d AT CORNER POST.) PER NOTE/4. .I Y/ SEE 3/2 - NAIL PURUN ETAR.417. 5-12d(TYP.) 7a FASCA LOOKOUT 2 x LEDGER PER n - W 4-12d I// POST I MAIL p BEAM W/ 2 z BLOCK W/WIDTH o BOLTS PER(-__, ip •) 12d 0 10'O.C. TO MATCH POST. SCHEDULE TRUSS 7I- POST STAGGERED. NAR W/15-12d 2x6 LOOKOUT FACH I AT FACA END OF UP (B-12d AT CORNER POSE) •O1 SIMPSON UTS16 STRAP SIDE OF POST AS SHOWN E w z 2 x BLOCK EACH • AT CIRARALL • .D+ S1DE OF POST W/ TRUSS(WHERE OCCURS) S REWS FOR ® F� �MT4R0 TOP ppST SCHEDULE O '- o WIDTH TO MATCH n w/(7)10d x 1J4" GIRT PER ® RNANG CONSTRUCTION OF GIB TS W/(4)ON �- WALL PANELS POST. 4 x BLOCK - ONLY,SEE DETAA i 2 TRUSS OR RAFTER NAILS®POST NOTE ff4. / 10d X 1 1/2• NOh: of FOR DOUBLE TRUSSES. OR iRU55 CONNECTION _ ........ 11lIASES.OR RAPIERS(TYP.) w a.w d:(7) 10d x Ti.,. ••'• NA1L5 AT EACH GIRT BOTH SPLICE CONFIGURATIONS NOTE• cti NAILS 0 TRUSS AND DETAIL 9/2 FOR PAVE Glt(f OR AS PER LEDGER SUPPORTS w 31 ARE EQUALLY STRONG,EITHER a a w a RAFTER CONNECTION CAME GIRT SCHEDULE M PURUNS AND NEED WALL PANELS PER POST PER SCHEDULE A 2%6 BLOCK ONE MAY BE USED AT THE NOT EXTEND TO OR NOTE N4 OR/11 BUILDERS DISCRETION ATTACH TO POSTS. WIDEST DIMENSION OF Y w I�NWWI -124 ENDWALL POST U.N.O. U --�1--WIDEST DIMENSION .O. C- h t SECTI OF POST U-N ON AT EAVE RHANG FRAMING DETAIN- SECT. TH U PURLIN AT TRUSS/RAFTER 4 PURLIN SPLICE DETAIL SA SECTION AT RAKE 2 ltt'-0' 1'-1'-0' 2 1'-1'-0• - 2 r-r-p' 2 1'.1•-D• suols)na� _BAY WIDTH 24"MAX- ROOF PANEL SCREWS FOR RAKE RAPIER SCAB 0 STEEL IWIOFA. F PANEL SCREWS FOR BEAM PER NOTE/4 12-12d EACH SIDE,(INSIDE PER Z RAKE BEAM PER SIMPSON U O OR ROOF PANEL SCREWS AS RtK£OEAU PER NOTE/4. BAY WIDTH 24•MAX. PLY ONLY IF 2-PLY.) SCHEDULE G SCHEDULE F W PANEL+LRkW' 011Al W/ IIe x FOR ONE SIAM PER IE/4 ?j FOR RAKE PER -12d PURU14 TO -2x5 BLOCKING NOTE/4. 1/2•IWLS LNDNW 2x6 BLOCKI Id AT POST lot" FiAUN 4-12d PURIAT TO MAIL SCAB TO R m I-12d W EACH S4 OCK(ELpNUI_ TO EHOYYALL (SAME R WITH 0-120 ON , 4-12d TO EACH PURLIN AT CORNER CK •EACH 0 TQ SIDE OF POST W BLOCK T AKE 7P4•EACH 12d 0 C.STAGGERED 10 RAKE I • (n O RAKE 3-12d TOENAIL FAG _ PURLIN 121 RAKE TO POST. TOP CHORD PURLIN TO EACH RAKE SAM OMIT PURLIN I • -SCAB J PURLIN PER 4. •I• Q d 120 AT CORNER POST) 2ND RAKE BEAM CA9CA CACNtlPURIIN WALL PANEL SCREWS SCNM� 0 - I--" W 2 x LEDGER PER SAME AS FOR WITH SCHEDULE F. OR SCAB PER /4-1•A•d TO TRUSS W NAIL TO BEAM W 2 z BLOCK W/WIDTH SCHEDULE FF PER NOTE/4 , / TO MATCH POST. ENDWALL POST (WHERE OCCURS) 12-120 RAKE TO ENDWALL 2xfi FASCIA 12d 0 10"O.C. NAIL W/B-12d. TRUSS -_ STAGGERED. (4-12d AT CORNER POST.) / - RAFTER = POST FOR CONTINUOUS WE. W 4-12d 2 x 6 BLOCK. TRUSS (4-174 FOR SINGLE SPAN ENDWALL POST AND AT CORNER POSi.)(IYP.) TRUSS TOP CHORD d 2 x BLOCK EACH SIDE NUMBER UOITL TO WTCII ALl PANELS BLOCK W/WIDTH a P05T W WIDTH TO BSp� OF NAILS 2 x BLOCK EACH WCE • 2 x 6 OLOCK. TO TCN POS/. WALL PANELS MATCH PpSf _ OF ppST W/K401H 10 POST PER W B-12d, BEVEL TO YATCN 10' IS YATCN POST SCHEDULE B TRUSS SPACING NAIL B-124(TIP•) ATTACH BLOCK 10 PER MOLE 2 RAKE SLOPE- 12• 17 - - ATTACH BLOCK TO POST WALL ELS SHEET 3/ IWL W/0-12d, TRU INO W//OVANUff Of 1 LI W/QUAMITY OF 12d / (OIAY REOUWED N WALL PAR I'EP IC/2. T'CA SCHEDULE 14• 22 RAILS PER SCHEDULE. SCAB NND 5• /3 PIIBTEMI.PORE OF WMEST ENOWALL�Post , p E OF OCCURS WIDEST a-NS1O11 OF SECTION v¢R POST K 3 INTERIOR POST PER SCHEDULE K B i WIDEST MYENSION DNDRALL U N-0. 5 SECTION AT RAKE ENDWALL PAST U.N.O. - SECTION AT ENDWALL W TRUSS 5 S CTI N A DW L W OVERHAN SECTION AT ENDWALL W OVER G 6 INTERIOR POST RAFTER CONNECTION =o 0 2 » Y 1'.1•_p• 1._t._O. 2 1 1'-0• 2 1._1."O' - L)�J p� 4-12d PVRLNI POY 02NLYN2-�PIY.)( O _WO(:ERIER W/L SCAB TO RAFTER 0 ill• 6-12d lOEP1KT W/ 120T ¢¢ a o TO POST O.C.STAGGERED (T-GWTS o1,1.Y REOURE0 4. 6-1 EACH RAFTER 4-12d PURUN OP OVERHANG IF 1_ AT w BAYS) R.h m EACH (INSIDE TO BLOCK(TYP.) METAL ROOFING VIED DETAIL 2/2 LL PLY Oft 2-PLY.) _ ` to w 5-12tl EACH 4EMBER ROOF WS STUB POST WIDIN TO TIE 51 MAY NOT BE REO'D. NAIL TO POS2.6 GIRT T EACH SIDE FOR PllRltl NONE/4 MATCH SIDEW POST SEE' LL 3-12d DRWEN Al i 0 I I, EAVE GIRT ANGLE (IYP.) TIE STRAP W/ x 1-1/2• WALL PANELS PER d•p .I I • • _ NAILS PER SO Y EASE •LIFT NOTE/4 OR IH I I WALL PANEL SCRLWS 1 __ a• XU AT POST � � O • I' I• I• I FOR GIRT FOR NOTE/4. •1 • _- • I• •I 1L[jl E;SHIM RAFTERS AND L • ROVER PER O ALTERNATE GIRT: BLOCKS TO MATCH WIDTH SGNLT1UlE G ® 0 2.24?xOC W/3-12d N.t OF INTERIOR POST. n EQUAL NUMBER •3-12d FACH GIRT PER CONNECTION EACH S1DE OF POST. ALTERNATE LOCATION 2 x BLOCK EACH SIDE IUIL SCAB TO RARER �1 (2) / OF POLE w/WIOTN TO WITH(8)12d ON EACH 2 x BLOCK EACH RAFTERS PER ® 10'RAFIER SPANS AND R OF TIE STRAP MATCH POST, SIDE OF POST SIDE OF POST W/WIDTH SCAB TO RAFTER () / 2z6 GIRT. FACE ATTACH BLOCK TD LO MATCH POST. (0)12d ON EACH SCHEDULE G 3 3 4"0 BOLTS SIDEWALL POST M WITH QUANTITY OF d NAILS ARACN OCK TO POST OVER 10'SPAN NAIL W/3-120 PER SCHEDULE BLOCK SIZE TO CONTINUOUS RAFTERS YA1H 10QL 120 NAIS 9 0/POST ( ) (1)BLOCK BOLT PER OR POST MATCH POST OR PER SCHEDULE G SCHEDULE G NOTE 2x6 T-OW. MAIL KIJI NO SCHEDULE K BUILD TO MATCH OR TRUSSNTOP CHORD POST PER IEDULE A PER NOTE ) WALL PANELS 2 z BLOEK EACH RE STRAP AL can TOGETHER` 10• IS OR CANTILEVERED NOTE/4 OR �I(�� NOTE: 1 17 RAKE BEAM T MATCH STUD T. FOR T CONN. 22 OF POST U,fl,p, 4 x W= OR SEE OCTNL 2 T-GIRTS ONLY DOUBLE ERS REQUIRED AT 14' BAYS AND 24'UP RIDGE POST RAFTER CONNECTION TYPICAL EAVE GIRT SPLICE e WALL GIRT DETAIL FROM BASE OF WALL N POST RIDGE CONNECTION SID WALL POST RAFT CONNEC710D RAFT R TRU S CONNECTION WHEN NO SLAB OF 1'1'-O' 2 1'./'-p" 2 1'.1'-0• 2 1-.1'-0' 'z 1'.1'-0' .1 1.-1'_0• 2X6 GIRT TOE-NAILED NARROW DIMENSION TOE NAIL 20 PURUN (2)2x6 BLOCK BETWEEN TO SKREED W/12d OF POST. (TO MATCH T-GIRT TO 4)124 FROM PURUNS,NAIL BLOCKS AT B'O,C, POST SIDEWALL POST) POST W/3-12d pURIA WRAP STRAP OVER 7O EA, 0.1`I<xA,NAILS ;yS'AC 'o4C POST /'� (TMP') BLOCK AND PURLIN (1YP-) STRAP_ FORWALL PANEL SCREINSGIRT PER N01E/4 ,.Q ,.o..'�\ BLOCK ,y�r �� O 4•CONCRETE O �� Ix x C L 16d GALVANIZED FLOOR SLAB a 6 Q Q' \ I•'• T51RL N CND TO G t VV At S, ®10"o.c. $ - 2x4 T-GIRT Z '4 SIMPSON C516 WRAPPED AROUND (y�12d EACH OR L ••`i `.2• : N 2.4 P.T.GIRT '� `t"'•i.; _ Q PURUNS,BLOCK.AND ONTO I• M HOER (TYP'O T �•. Z >?'' P KNEE BRACE.ATTACH r/ BLOCK ONLY) S , 4'MIN. 4 \ p Q \ (5)12d(MIN).NAILS EACH 11EUBE I • 2A!BRACE w/(4) 1 J bx BLOCK BETWEEN STEELS 12d TOENAILS EA SIDE y 1l A TRUSS ANCHOR I EMBED Q �' 'C ETNOWIEA RIDGE PURUNS (PER NT IO)w/(12)/AIL OF DBL BLOCK L� U��yI{ ttteE �•)�.scom1: L•E,,, SIMPSON HETA 16" I I iGOTING A�Q ..�: POST POST W�/BxIWOOD SCREWS ATNOTE, 1 11y •`T' GY ",•� RTi1 Z Q W/16d NAILS. DBL BLOCK BEND AROUND I Q _ `' 1 16 0.Q WHERE LENGTH OF BRACE ♦ tF•1. �1A POST NNO 1lAR. I BACK FILL& WHERE LENGTH OF BRACE !� d•.0 14- �j Q EXCEEDS 5'-6"ADD FLAT v• ti Q 2)ANCHORS PER I LL p; COMPACTIONTff _ EXCEEDS 5'-6'ADD FLAT �.•Y, '7"BRACE 75R OF LENGTH OF SAME PER � --- - T BRACE 75X OF LENGTI �• .PF 1(1\(969 � �y N EXCEPT(1 NtCIIOR Q Q- \ NOTE J(9 Q FACE 2x4 TO 12d 0 10".. 2e O io"LAC. ti 1.• (q E IOR CO POSTS. \ W/3-12tl F p14 •,I 2x4 T •,i 2x4'7• pW,((1 Ar:.?�i�1 i'�w-t,,:.'�14y``L✓ Q I/�♦ [•LATE$; �' _�-:V 6"CONCRETE PAD lO W B-12d . 2xB HF 2 0 �\ •1 • ti Z V / I S. Bx&EF/2 DIAGONAL tR BRACE TO ROOF `��'S1'�}.-fi t eT 1, USE P.T.T-GIRT AS PER DETAIL 12/2 AT •� ELEVATION I - R.CN�', `� BASE OF WALL WHEN NO SLAB ��� �` n � 12 UR SCEIWE TER M ACE MAY NOT BE REO'D. EAVE EQUALLY LY NAILS SPACED (12) 12d NAILS A y� EOl/ALLY EACH WAY � �YF_ • SPACED EQUALLY EACH WAY � ���// *7 sheetSCHEDU H AND P LE K. HEIGHT u i1bG17T I v ` 2 )3 BASE GIRT DETAIL 6 EMB DDED POST FOOTING W/ PAD ) INTERIOR POST BRACE DETAIL 20 ENDWALL POST BRACE DETAIL 20 ENDWALL POST BRACE OET _ y 1.1-0 2 V4'-I'-p' 1''1'-0' 2 C-C-0, POST AT RIDGE) 2 1•-1'-0' 3 o M SIDEWALL POST SCHEDULE �r—_1ENDWALL POST SCHEDULE w/ BRACE PER DETAIL 20/2 cJi ALL BUILDING WIDTHS TO 40' " ALL BUILDING WIDTHS TO 40' �`, TRUSS BLOCK BOLT SCHEDULE NOTES: m POST MATERIAL: SEE NOTE #5 3 4' 0 MACHINE BOLTS W WASHERS POST MATERIAL: SEE NOTE #5 �r� —� 1.) ALL WORK AND MATERIALS SHALL CONFORM TO THE 2015 IBC (INTERNATIONAL BUILDING CODE). o 3 v m BAY EAVE HEIGHT BUILDING EAVE HEIGHT CONTRACTOR IS RESPONSIBLE FOR ALL METHODS AND MEANS. o v n WIDTH WIDTH BAY TRUSS SPAN S' 11' 12' 14' 15' 16' (SPAN) 8' 11' 12' 14' 15' 16' WIDTH 2.) TRUSS DESIGN AND FABRICATION SHALL CONFORM TO THE 2015 IBC (INTERNATIONAL 10' 4x6 4x6 4x' 6x4' 6x5' 6x8* * * * 20' 22' 30' 36' 40' BUILDING CODE). ENGINEERING DESIGN AND SHOP DRAWINGS SHALL BEAR 20' OR 30' 4x6 4x6 4x6 6x6 6x6 6x8* THE STAMP OF A PROFESSIONAL. ENGINEER REGISTERED IN THE STATE OF WASHINGTON. A _ 12' 4x6 4x6 6x6* 6x8** 6x8** 6x8* 10' 2 2 2 2 3 TRUSS BRACING SHALL BE IN ACCORDANCE WITH THE TRUSS DESIGN DRAWING. m 22' OR 32' 4x6 4x6 4x6 6x6* 6x6 6x8** 14' 4x6 6x6* 6x6* 6x8** 6x8* 6x8* 12' 2 2 2 3 3 3.) BUILDINGS SHOWN ON THESE PLANS HAVE BEEN DESIGNED FOR THE FOLLOWING o ?46, 34 OR 36 4x6 4x6 6x6* 6x6* 6x8** 6xB* E w o LOADING: � NOTE: *" DENOTES OPTIONAL GRADE/SCAB PER * * * 14' 2 2 3 3 4 ROOF SNOW LOAD: 25 psf DESIGN WIND SPEED: 110 MPH, EXPOSURE B. E o o NOTE 5. 26' OR 38' 4x6 4x6 6x6 6x6 6x8 6x8 (3 sec yust) **" DENOTES N0. 2 GRADE 28' OR 40' 4x6 4x6 6x6* 6x8** 6x8* 6x8* SEE DETAIL 1/2 OR 2/2 SOIL BEARING: 2000 psf OR 1500 psf %' DENOTES ONE SIZE SMALLER 6x_ 2 (PER SCHEDULES) w o # NOTE: "*" DENOTES OPTIONAL GRADE/SCAB PER GRADE PLUS 2x6 P.T. HF 2 SCAB SAME NOTE 5. �\ PURLIN SCHEDULE SEISMIC DESIGN CATEGORY: D AS FOR GRADE/SCAB OPTION PER NOTE 5. ° f f DENOTES N0. 2 GRADE �" WITH Ss = 150%g MAX. POST MATERIAL: 6x_ HF#2 ROUGH "%" DENOTES ONE SIZE SMALLER 6x— #2 2 SCAB SAME f EAVE HEIGHT GRADE PLUS 2x6 P.T. HF# BAY WIDTH PURLIN/SPACING 4.) METAL PANELS SHALL BE BHP NOR CLAD, OR EQUAL, HAVING 80 KSI MINIMUM YIELD BAY AS FOR GRADE/SCAB OPTION PER NOTE 5. STRENGTH. ROOF PANELS SHALL BE FASTENED WITH #14 x 1-1/2" SELF TAPPING WIDTH 10' 11' 12' 14' 15' 16' SCREWS AT 9" O.C. ALONG EACH PURLIN AND EACH RAKE BEAM. WALL PANELS POST MATERIAL: 6x— HF#2 ROUGH 10' 2X6 0 24" O.C. SHALL BE FASTENED WITH g10 x 1-1/2" SELF TAPPING SCREWS AT 9" o.c. ALONG 10' — — — 6x8% 6x8 % 6x10% BUILDING EAVE HEIGHT EACH GIRT. SEE SHT. 1 FOR METAL GAUGE. 0 WIDTH z 12' — — — 6x8% 6x8 6x10% 5.) LUMBER SHALL CONFORM TO THE FOLLOWING U.N.O. ON THESE PLANS: (n (SPAN) 10' 11' 12' 14' 15' 16' 2X6 0 24" O.C. W 2X4 THRU 2X6: HF NO. 2 14' — — 6x87 6x8 6x10% 6x10% 20' OR 30' 6x6 6x6 6x6 6x8% 6x8% 6x8 12 2X8 THRU 2x12: DFL NO. 2 O m STRUCTURAL POSTS: 4x6 HF NO. 2 S4S Z w NOTE ALL CORNER POSTS 4X6 — ORIENTATION 22' OR 32' 6x6 6x6 6x8% 6x8% 6x8 6x8 2X6 0 16" O.C. 6x6 & LARGER HF NO.1 ROUGH SAWN & AS NOTED. O_ NOT CRITICAL EXCEPT IF ADJACENT TO POSTS NOTED WITH *" MAY BE NO. 2 GRADE PLUS 2x6 PT HF NO. 2 Q 4', 34' OR 36 6x6 6x6 6x8% 6x8% 6x8 6x10% 2X6 DFL NO. 2 0 18" O.C. SCAB APPLIED ON INSIDE FACE OF POST EXTENDING FROM FTG PAD TO Z AN OPENING THEN WIDEST DIMENSION 14' 1/3 THE EAVE HEIGHT ABOVE GRADE. NAIL SCAB WITH (4) ROWS J Q d OF POST IS TO BE PARALLEL TO THE THE WALL OPENING. 26' OR 38' 6x6 6x8 6x8% 6x8 6x10% 6X10% 2X6 0 48" O.C. + (2) 2x6 0.131 DIA x 3-1/4" GALV NAILS SPACED 6" OC EACH ROW. <to (OPTIONAL CORNER POST 6x6 HF#2) % % 48" O.C. (ALTERNATING) x 28' OR 40' 6x6 6x8 6x8 6x8 6X10 6X10% W J W NOTE BLOCK BETWEEN PURLINS AT BLOCKING: HF STANDARD AND BETTER :D _ LAP IF SPACED DIFFERENTLY 6.) EMBEDDED STRUCTURAL POSTS SHALL BE PRESERVATIVE TREATED USING TREATMENT FOR 0 0_ RAKE BEAM W OVERHANG SCHEDULE AT ADJACENT BAYS 0.60 cf RETENTION IN CONFORMANCE WITH AWPA USE STANDARD UC48• ALL OTHER w F / �\ RAKE BEAM SCHEDULE P = F LUMBER IN CONTACT WITH SOIL OR CONCRETE, OR EXPOSED TO WEATHER SHALL BE U O PRESERVATIVE TREATED FOR 0.40 pcf RETENTION. NAILS USED WITH PRESERVATIVE TREATED v) INTERIOR RAFTER SCHEDULE LUMBER OR BELOW GRADE SHALL BE HOT—DIPPED GALVANIZED. BAY BEAM SPAN BAY BEAM SPAN _ GRID SYSTEM 7.) BOLTS SHALL CONFORM TO ASTM A307 AND HAVE WASHERS UNDER EACH HEAD AND NUT WIDTH 10 12' 14' WIDTH 10' qW/ 14' U.N.O_ PRE—BORE BOLT HOLES 1/16" LARGER THAN BOLT DIAMETER. RAFTER SPAN ' 1A (2)2X (2)2X1 (2)2X12 BAY B.) CONCRETE SHALL HAVE A 28 DAY MINIMUM COMPRESSIVE STRENGTH OF 3000 psi. FOR WEATHERING _ 10' 10' 2X10 W/ (2) 2X10 W/ WIDTH 10' 12' 14' ( Pa c (1)2X12 2X4 LEDGER 2X4 LEDGER 2500 psi USED FOR DESIGN, SPECIAL INSPECTION IS NOT REQUIRED). 2X12 W/ 8 SCAB 2X12 W/2X8 SCAB C J~ 9.) BACKFILL FOR EMBEDDED POSTS SHALL BE CLEAN SAND. (2)2X10 )2X10 (2)2X12 2X10 W/ (2) 2X10 W/ 10' (2 10 (2)2X12 m . (2)2X10 + COMPACTION SHALL BE BY MANUALLY TAMPING WITH A20 POUNDJW12' 12 2X4 LEDGER (2)2XB SCABS MINIMUM STEEL TAMPING BAR IN LIFTS NOT TO EXCEED 8"_ a o° (1)2X12 X12 W 2X4 LEDGER 10 SCAB (2)2X10 (2)2X12 + 10.) STEEL STRAP SHALL BE SIMPSON CS16 OR EQUAL 12' (2)2X10 (2)2X10 2X12 (2)2x12 74, 2X12 W/ (z) 2X10 W/ (2) 2X12 W/ (2)2XB S BS (2)2X10 SCABS a 14' 2X6 LEDGER 2X4 LEDGER 2X6 LEDGER 11.) 19/32" T1-11 OR LP SIDING MAY BE USED IN PLACE OF METAL PANELS ALONG Oo 2X12 W/2X8 S B (2)2X12 + ENDWALLS AND SIDEWALLS. SIDING SHALL BE NAILED WITH 6d COMMON OR n DETAIL 5A/2 DETAIL 5B/2 DETAIL 5B/2 14 (2)2X12 /Xlo (2)2X10 SCABS GALVANIZED BOX NAILS AT 4" O.C. ALONG PANEL EDGES AND 12" O.C. IN FIELD. RAKE BEAM NOTES SCH LE F AND FF: ALL EDGES OF SIDING TO BE BLOCKED. FOR SHIPLAPPED EDGES BOTH PANELS SHALL r ( ) BE EDGE NAILED WITH 6d AT 4" O.C. IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 1) SCAB OR 2ND RAKE 8 IS TO SPAN BEAM NOTES 1. QUANTITY OF R OR RAFTERS + SCABS i BETWEEN POSTS. SCAB OR 2ND IS TOTAL NU R GRID w/ EQUAL NUMBER 12-) CONSTRUCTION OPTIONS WHERE SHOWN ARE AT THE BUILDER'S DISCRETION. 2) WHERE CANTILEVER OCCURS 0 RAKE BETWEEN POST EACH SIDE POST. BEAM TO BE CONTINUOUS AND A OLLAR TIE CL BEAM & SCAB 2. WHERE N AIJTILEVER CURS 2ND RAFTER OR 13.) INS NAILS ARE 0.131" DIA. x EAT 4" HOG. 1TO NAILS ARE 0.162" DIA, x 3-1/2" HDG. NAILS IS REQUIRED AT CANTILEVER. SEE AIL 1 BELOW. SCABS A TO SPAN B EN POSTS. INSTALLED IN PRESERVATIVE TREATED LUMBER TO BE HOT DIPPED GALVANIZED OR EQUIVALENT. � 12d 0 10" O.C. 3. WHERE LEVER OCCU 2ND RAFTER OR (STAGGERED) SCAB 1F SPECIFIED) IS TO THE LENGTH OF INTERIOR POST SCHEDULE TH FTER SPAN + 2' AND NO 4' BEYOND K SYM 1 RIOR POST, SEE DETAIL 2 B W. YSTEM ® � RIDGE BLOCK 4. ERS AND SCABS TO BE SPIK TOGETHER w/ 12d NAILS AT 10"o.c. STAGGER (U.N.O.) BAY AVE HEIGHT CONT OUS RAKE BEAM WIDTH RAFTER 8' 10' 1 14' 15' 16' 2ND RAFTER OR SCAB 10' 4X6 4X6 6 4X6 6 * 4X6 6X6 RAKE BEAM PLUS RAFTER & S B 12' 4 4X6 * 4X6 * 4X6 4X6 * 6X6 SCAB OR SECOND RAKE BEAM 4X6 4X6 * 4X6 * 4X6 * 6X6 6X6 WHERE OCCURS 12d 0 10" O.C. i�KE AN PER SCHEDULE SYM (STAGGERED) TO RAKE i PER SCHEDULE � � THESE POSTS TO BE BRACED PER red BELOW d'0 @ � DETAIL 17/2 OR USE 6x6 POST. (n3 � u� z ENDWALL ST PER P "v �� OG S PACING S Z M EAVE GIRT TIE STRAP y !� "!�r Lo N :1 S! z COLLARTIE AN C CTION SCHEDULE GIN BLDG. / / BLDG. TIE STRAP PER DETAIL 11 2 OR 2 2 QP LENGTH MLS BAY ENDW L POST S CING (AT RIDGE) QpS� RIDGE BLOCK WIDTH NO TIE BLDG. LENGTHOUAN"ry al z Z Q WIDTH ox 20' 35' MAX. 36' TO 60' 5 12 � s.• 1 , ,Y) Qc O 1 12 14 EACH ROW 2 ROWS 2ATuCANTILEVER e. ^ G 7COLLARTIE N 9 2x8 WIT 1 2x10 WITH (13) 22' 39' MAX 1.: "y 'aH?/ .ehn AC NO NAILS EACH 0 NAILS EACH END �,y� 199a3 ZA TH 11) 2x10 WITH 1 2x10 WITH 15 NO OR 28' 43' MAX, 44' TO 84' 6 13 g,� ACH END NAILS EACH EN ILS EACH END SCAB ACHED T PER PLAN L ti^tiY i' � � = U ITH (13) 2xi0 WITH (1 B) 12 WITH (1$) WI 12d AT 32' 48' MAX. 49 TO 96' 7 14 � .. „� '"� ACH END NAILS EACH END NA EACH END O.C. STAGGERED 36' 52' MAX. 53' TO 106 8 15 �bh 1 Y iV d ST SPACING uy• sheet SEE DETAIL 6/2 40' 57' MAX. 58' TO 120' 9 16 ' IL AT RAKE BEAM RIDGE 2 ICAL RAFTER SCAB FOR ADDITIONAL INFO TION ^/ //i/g� 3 COLLARTIE NOT REQUIRED WITH SINGLE RAKE NOTE: NAIL QTY'S SHOWN ARE EACH SIDE OF SPLICE. ` /V r 1 Z WHERE OVERHANG OCCURS, SEE DETAIL 2/2. J • a SIDEWALL POST FOOTING SCHEDULE WITH CLEARSPAN TRUSS r \ SIDEWALL POST FOOTING SCHEDULE WITH GRID (OR ENDWALL WITH CLEARSPAN OR GRID) tn u INTERIOR POST FOOTING SCHEDULE a o GRID SYSTEM LLOWABLE SOIL BEARING = 2,000 sf LLOWABLE SOIL BEARING - 2,000 sf BUILDING -3 EAVE HEIGHT EAVE HEIGHT OWABLE SOIL BEARING 2,000 P >o BA WIDTH BA POST n o-a WIDTH USS SPAN) 10' 11' 12' 14' 15' WIDTH SPACING 10' 11 12' 14 15' 16' POST BAY WIDTH SPACING 10' 12' 14' 24' OR S 18 dia. x 18" dia. x 18" dia. x 18" dia. x 18" dia. 18" dia. x 18" dia. x 18" dia. x 18" dia. x 18" dio. x 18` di 18" dio. x 4—0" DEEP 4'-0" DEEP 4'-0" DEEP 4'-0" DEEP 4'-0" EP 4'-0" DEEP 1 O 4'-0" DEEP 4'-0" DEEP 4'-0" DEEP 4'-0" DEEP 4'— EEP 4'-0" DEEP 10' 1 " dia. 18" 1a. 18" dia. 10' " dia, x 18" dia. x 18" dia. x 18" dia. x 8" dia. x 18" dia. x 10' . x 18" dia. x 18" dia, x 18" dia_ 18" dia. x 18" dia. x 12' 18" 1 dia. 18" dia. z— 32' OR LESS 4'— EEP 4'-0" DEEP 4'-0" DEEP 4'-0" 4'-0" DEEP 4'-0" DEEP 12 4'— EEP 4'-0" DEEP 4'-0" DEEP 4'-0" P 4'-0" DEEP 4'-0" DEEP °1 14' 18" dia. 18" dia. 18" dia. o 0 24" dia, x 4" dia. x 24" dia. x dia. x 24" dia. x 24" dia. x 18 dia. x 18" dia. x 18" dia. x dia. x 18" dia, z 18" dia. x E o 40' OR LESS 4'-0" DEEP 4 " DEEP 4'-0" DEE —O" DEEP 4'-0" DEEP 4'-0" DEEP 14 4'-0" DEEP 4 " DEEP 4'-0" DE 4'-0" DEEP 4'-3" DEEP 4'-3". DEEP `_ ALLOWABLE S 8EAR1 — 1,500 PSI .- 18" dia. x 18" dia. 18 a. x 18" dia. x 18" dia. x 18" dia. x18" dio. x 18" di 18" 1a. x 18" dia. x 18" dio. x 18' dia, x �z`o 24' OR LESS 4'-0" DEEP 4'-0" DEE " DEEP 4'-0" DEEP 4'-0" DEEP 4'-0" DEEP 10' 4'-0" DEEP 4'-0' DEE —0" DEEP 4'-0" DEEP 4'-0" DEEP 4'-0" DEEP POST BAY TH > SPACING 01�' 18" dia. x 18" dl 18 x 18" dio. x 18" dia. x 18" dia. x 18" dia. x IS' , x 18 ' . x 18" dia. x 18" dia, x 18" dia. x 10' 12' 14' 12 32' OR LESS 4'-0" DEEP 4'— EEP 4'-0" 4'-0" DEEP 4'-0" DEEP 4'-0" DEEP 12 12 4'—D" DEEP 4' DEEP 4'-0" 4'—O" DEEP 4'-0" DEEP 4'—0' DEEP 10' 18" dia. 16" dia. 8" dio, o N n 24" dia. 24' dia. x 24" dia. x dia. x 24" dia. x 24" dia. x 18" dia. 18" dia. x 18" dia. x dia. x 18" dia. x 18" dia. x a 40' OR LESS 4'-0" P 4'-0" DEEP 4'-0" DEEP 4'— EEP 4'-0" DEEP 4'-0" DEEP 14 4'-0" EP 4'-0" DEEP 4'-0" DEEP 4'— EEP 4'-3' DEEP 4'-3' DEEP 1 18" dia. 18" dia. 24 dia. S1JVWW dia. x 18" dia. x 18" dia. x 18" dia. x 18" dia. x 18" dia, x dia. x 18" dia. x 18" dia. x 18" dia. x 18" dio. x 18" dia, x 4 1B' dia. 24" dia. 24" d1 24' OR LES 4'-0" DEEP 4'-0" DEEP 4'-0" DEEP 4'-0" DEEP 4 " DEEP 4'-3" DEEP 10 4'-0" DEEP 4'-0" DEEP 4'-0" DEEP 4'-0' DEEP 4 DEEP 4'—O" DEEP ALL FOOTINGS 4'-0" DEEP 14' 24" dia. x 24" dia. x 24" dia. x 24" dia. x 24'� dio. 24" dia. x 14' 18" dia, x 18" dia. x 18" dia. x 18' dio. x 18",dia. 18" dio. x 32' LESS 4—0' DEEP 4'-0" DEEP 4'-0" DEEP 4'-0" DEEP 4'-3" DEE —3" DEEP 12 4'-0" DEEP 4'-0" DEEP 4'-0" DEEP 4'-0" DEEP 4'-0" DEE —0" DEEP W 24" dia. x 24" dia, x 24' dia. x 24" dia. x 24" dia. x '24 x 18" dia, x 18" dia, x 18" dia. x 1B" dia. x 18" dia, x 18' x p J LLJ m 40' OR LESS 4'-0" DEEP 4'-0" DEEP 4'—0' DEEP 4'-0" DEEP 4'-3" DEEP 4'-3" 14 4'-0" DEEP 4'—O" DEEP 4'-0" DEEP 4'—O" DEEP 4'-3" DEEP 4'-3" W 1K = W N NOTE: DEPTHS ARE TO TOP OF CONCRETE PAD. NOTE: DEPTHS ARE TO TOP OF CONCRETE PAD. 0p' CORNER POST FOOTINGS ARE CORNER POST FOOTINGS ARE In 13 18" DIA. x 4'-0" DEEP. 18" DIA. x 4'-0" DEEP. U w CD ALLOWABLE SOIL BEARING 1500 psf ALLOWABLE SOIL BEARING 1500 psf Z_ BAY BUILDING SAVE HEIGHT BAY POST EAVE HEIGHT _ WIDTH WIDTH WIDTH SPACING p (TRUSS SPAN) 8' 11' 12' 14' 15' 16, 8' 11' 12' 14' • 15' 16' 1-1- 18" dia. x 18" dia. x 18 dia. x 18" dia, x 18" dia. x 18" dia. x 18" dia. x 18" dia. x 18" dio, x 18" dia. x 18" dia. x 18" dia. x O 24' OR LESS 4'-0" DEEP 4'—O" DEEP 4'-3" DEEP 4'-3" DEEP 4'-6" DEEP 4'-9" DEEP 10 4'-0" DEEP 4'-0" DEEP 4'-3' DEEP 4'— DEEP DEEP 4'-6" DEEP 4'-9" DEEP 10' 24" dia. x 24" dia. x 24" dia. x 24" dia. x 24" dia. x 24" dia. x 10' 18" dia. x 18" dia. x 18" dia, x 18" dio. x 18" dia. x 18" dia. x 32' OR LESS 4' 0" DEEP 4'-0" DEEP 4'-3" DEEP 4'-3" DEEP 4'-6" DEEP 4'-9" DEEP 12' 4'-0" DEEP 4'-3" DEEP 4'-6" DEEP 4'-6" DEEP 4'-6" DEEP 4'-9" DEEP ° N z 40' OR LESS 24" dia. x 24" dia. x 24" dia. x 24" dia. x 24" dia, x 24" dia. x 18" dia. x 18" dio. x 18" dia. x 1B" dia. x 18" dia, x 18" dia. x v_Z 4—0'� DEEP 4'-0" DEEP 4'-3" DEEP 4'-3" DEEP 4'-6" DEEP 4'-9" DEEP 14• 4'-0" DEEP 4'-3" DEEP 4'-6" DEEP 4'-6" DEEP 4'-9" DEEP 5'-0" DEEP 24" dia, x 24" dia. x 24" dia. x 24" dio. x 24" dia. x 24" dio. x 18" dia, x 18" dia x 18" dia. x 18" dia. x 18" dia. x 18" dia, x O co a 24' OR LESS 4'-0" DEEP 4'-3" DEEP 4'-6" DEEP 4'-6" DEEP 4'-6" DEEP 4'-9" DEEP 10 4'-0" DEEP 4'-0" DEEP 4'-3" DEEP 4'-3" DEEP 4'-6" DEEP 4'-9" DEEP 12 24" dia. x 24" dia, x 24" dia. x 24" dia. x 24" dia. x 24" dia. x 18'' dia. x 18" dio. x 18" dia. x 18" dia, x 18" dia. x 16" dia. x 32' OR LESS 4 0" DEEP 4'-3" DEEP 4'-6" DEEP 4'-6" DEEP 4'-6" DEEP 4'-9" DEEP 12 11 4'-0" DEEP4'-3" DEEP 4'-6" DEEP 4'-6" DEEP 4'-6" DEEP 4'-9" DEEP C 24" dia. x 24" dia, x 24" dia. x 24" dia. x 24" dia. x 24" dia, x 18" dia. x 18' dia. x 18" dia, x 18" dia. x 18" dia, x 18" dia. x S 40' OR LESS 4'-0" DEEP 4'-3" DEEP 4'-6" DEEP 4'-6" DEEP 4'-6" DEEP 4'-9" DEEP 14 4'-0" DEEP 4'-3" DEEP 4'-6" DEEP 4'-6" DEEP 4'-9" DEEP 5'-0' DEEP p' ti 24" dia. x 24" dia. x 24" dia. x 24" dia. x 24" dia. x 24" dia. x 18" dia. x 18" dia. x 18" dia. x 18" dia_ x 18" dia, x 18" dia. x 4 4�1,� 24' OR LESS 10' o 4—0 DEEP 4'-3' DEEP 4'-6' DEEP 4'-6' DEEP 4'-9' DEEP 5'-0' DEEP 4'-0" DEEP 4'-0" DEEP 4'-3" DEEP 4'-3" DEEP 4'-6" DEEP 4'-9" DEEP 14' 24" dia. x 24" dia. x 24" dia, x 24" dia, x 24" dia. x 24" dia. x 14' 18" dia. x 18' dia. x 18" dia. x 18" dia. x 18" dio. x 18" dia. x Mro 32 OR LESS 4'-0" DEEP 4'-3" DEEP 4'-6" DEEP 4'-6" DEEP 4'-9" DEEP 5'-0" DEEP 12 4'—0" DEEP 4'-3" DEEP 4'-6" DEEP 4'-6" DEEP 4'-6" DEEP 4'-9" DEEP 40 OR LESS 27 dia. x 27" dia. x 27" dia. x 27" dio. x 27" dia. x T5d 18" dia. x 18" dia. x 18" dia. x 18" dia. x 18" dio. x 18" dia. x 4'-0" DEEP 4'-3" DEEP 4'-6" DEEP 4'-6" DEEP 4'-9" DEEP 14 4'-0" DEEP 4'-3" DEEP 4'-6" DEEP 4'-6" DEEP 4'-9" DEEP 5'-0" DEEP $x BLOCKc TO W1 '�i� yulTp(p� POST 0TN.GL WL£D I 10 P051 N/ 12d. 2-IGd r 1-1/2 NAILS IRaS$ NAIL CLADDING I AT FAGN GIRT 2x8 T1AxEO N Q 11 Y j ` 4� SYM �TO " _ , 1A.7'f.f 0 ri GIRTS PER N I-1 N, ' I " Q O DETAIL 12/20 GIRT POST A CD�Cry` Z�' •N• n �jECJJCLN A_A 6-12d(TYP.) •2 2.6 OR !LOON GINGER IF SECOND noon POST F A {{"{{����•• V'`,,� •'^1 ZI LL 6-12d Ie l` r �14.11W Q \l 2x4 BOTTOM GIRT 1Y�3 d TOEWA 20 J PLYWOW NAILED TO A '�y J • Qc STIFFEWR TO a• STIFFENERS 1' G 0 GIRT T1RN/ " I AND OOTs 1 W IOTAL STEEL STRAP EACH WAY PLYWOOD 2xI S NER ON EDGE ��y J,l' "" y"S"""• G�"�" li (x-BRACEI PEN loom 110 O 18�0. TOD4%TO GIRT •Ic Ap ]/S 1I i �J 10 01'E POST. MODEST poi ION O-PETAL 1 ';�,�'�tY��t�it'`1y6. .}. OF POST 11.0, I WALL PANELS TE1 ND t NI UPn 2'-0' LT�POST MAX OMM PER 1 X—BRACE STRAP ORT C ECTION I DUTCH GAMBREL DETAIL 1 /0 17 NJ S. N � 3 N 1 O > •C 2i 3i W g v � O N U) � H � m C 1c cd ■� .3 U N Qp A N _oj V♦ U � , > wo 0 o 00 4) co= vv o o U a apC uc) LLJ LL _ > c� }� (� L� cc V� N z Z cd cd o � o x o Q � ` / O Cm s �w LJ.I u ¢ J o cd ■ i r �v W o Cd o (� a cro x a o LIZ Z yy � q cd o o a k U N K o. f m a w rn O m V � a rn U a mmZo o z'c \ < C� d m m o a 4 ir ci orl LL i �1 I a z 0 . - U a _. E (r n >: cL LLI ED LL CO lzi E]0 0 El in o) 2 _o o) U- .0 -bJ cl -o o U) '0 E m (1) -5tz o c lo) ca 0. 0 2 00 Q) E fL + En .r- 0 Q>- 11 t I Z' E-v r oc E o , Z �L LLI �- co < lz7 w _j o z ci 2-0 S( a) 6' T rna z) 77 Ch co w C)Ll o -.o co 16 rv) Q j co o Lu u `2 u� NO J3A,I 1--J S; f; < o u- Lu CL cf) 0 00 i�l w-o al. IWC c? 02 (.,'. . Fn - 2 Lu �- (D ca 2 C) E w p z 0 TSE PR�T: JOB#: . ENGINEERING BY: 722 12810 NE 178TH ST.STE.218 JUL 1 20�7 DATE: Woodinville,WA 98072 A(425)481-6601 — *7 V r" Job Name: Harman Site Address: 17823 31 st Dr NE Arlington, WA 98223 Jurisdiction: City of Arlington Job ID: Harman Design Specifications: 2015 IBC Building Type: Post-Frame Design Wind Speed (a sec gust): 110 mph @ SD Level Wind Exposure: B Roof Snow Loading: 25 psf Risk Category: II R: 2.5 % of Snow Incl. w/Seismic: 0 % Soil Site Class: D Allowable Soil Bearing: 1500 psf Analysis Procedure: Wind: ASCE 7-10 Envelope Procedure i Seismic: ASCE 7-10 Equiv. Lateral Force Procedure Spectral Response Acceleration, Ss: 150 %g Load Combinations: ASD Basic I Building Design Parameters Roof DL: 3 psf Wall DL: 4 psf Nay �� t` d�4�4 ��a• ZONAL 017 v 5.9.07 b Draw Noah Arrow in Circle I my yq,avNC•llnm N.SW?903�31f>I�bramwu.r nnn:wluall Olr4al rssoos sssx ■ r ' {►y'�^/,y�'^,✓ ■ld'nN Design - 4z f.nynuvrriill .IselOea�eas>:eneubE � PLEASE CHECK Vrnd MPH O- 5'��P-,now door 411n Bays doors wi8 not hit Truss d Exposure 0o1 PIS Eave Height rl n, Load --l-L Minimum Clearance -- FLOOR PLAN - yc AL4 %t lo• t 21 3a6Q PtxM� wl Pn v - �,�✓ViSL �oo�= I It: 1 rll /O"/z J 22' 173 rc c�'e'• S�v i=,wary ' • 3°6�DcYM�wl Pao ^� IOK-7 Rgla- J /' x I '( ) Sr•h oe:T roc w7led)7AL.l-O-no W11AAX S 5'7k6jc5.,S - t i 1 - t • t Lr I, I h' 1 .J i — CA 1 BUILBING ELEVATION w Customer has verified and approved the orientation of the building to tho Nnh and ve 16os that all items specified in Paragraph B of the contract are shown on dtis Zmon and etas. elo III'lll�llllllllllll Customer Naule.(4n�..rl•�. Lead tl: ppf2(e,_CuatoularSlgnatora: o xTL.•Ca>tenur Cepy- Gnu;•(, Capr 01012 ParrM.... 9atOl Fn•a9 OI 12 - (t PROJECT: Harman PAGE: CLIENT: PermaBilt DESIGN BY: JOB NO.: 28009 DATE: 07/07/17 REVIEW BY: Wind Analysis for Low-rise Building,Based on ASCE 7-10 INPUT DATA Exposure category(a,C or D,ASCE 7-10 26.7.3) B Importance factor(ASCE 7-10 Table 1.5-2) I, = 1.00 for all Category Basic wind speed(ASCE 7-10 26,5.1 or 201216C) V = 110 mph Topographic factor(ASCE 7-10 26.8&Table 26.8-1) Kn = 1 Flat - a, Building height to eave he = 8 ft Building height to ridge hr = 11.6 ft �• Building length L = 22 ft E Building width B = 22 ft Effective area of components(or Solar Panel area) A = 50 ft7 DESIGN SUMMARY Max horizontal force normal to building length,L,face - 4.08 kips,SD level(LRFD level),Typ. Max horizontal force normal to building length,B,face = 3.45 kips See Page 4 for Adjusted Wind Forces ANALYSIS Velocity pressure qh=0.00266 Kh K,t Kd VZ = 18.43 psf where: qh=velocity pressure at mean roof height,h.(Eq.28.3-1 page 298&Eq.30.3-1 page 316) Kh=velocity pressure exposure coefficient evaluated at height,h,(Tab.28.3-1,pg 299) = 0.70 Kd=wind directionality factor.(Tab.26.6-1,for building,page 250) = 0.85 h=mean roof height = 9.80 ft <60 ft,{Satisfactory] (ASCE 7-10 26.2.1) <Min(L,B),[Satisfactory] (ASCE 7-10 26.2.2) Deslan_pressures for MWFRS p=qh[(G CPf)-(G CPr)l where: p=pressure in appropriate zone.(Eq.28.4-1,page 296). Pmin= 16 psf(ASCE 7-10 28.4.4) G CPf=product of gust effectfactor and external pressure coefficient,see table below.(Fig.28.4-1,page 300&301) G CPI=product of gust effect factor and internal pressure coefficient.(Tab.26.11-1,Enclosed Building,page 258) 0.18 or -0.18 a=width of edge strips,Fig 28.4-1,note 9,page 301, MAX[MIN(0.1 B,0.1 L,0.4h),MIN(0,04B,0.04L),3] = 3.00 ft Net Pressures li sf),Basic Load Cases Roof an le 0 = 18.12 Roof angle 0 = 0.00 Surface Net Pressure with Net Pressure with G CPt (+GCPI) (-GCPI) GCPf (+GCPi) (-GCPI) _ 1 0.51 6.15 12.79 -0.45 -11.61 -4.98 2 -0.69 -16.03 -9.40 -0,69 -16.03 -9.40 3 -0.47 -11.91 -5.28 -0.37 -10.14 -3.50 4 -0.41 -10.92 -4.28 -0.45 -11.61 4.98 5 0.40 4.05 10.69 6 429 -8.66 -2.03 1 E 0.78 10.99 17.62 -0.48 -12.16 -5.53 2E -1.07 -23.04 -16.40 -1.07 -23.04 -16.40 3E -0.67 -15.67 -9.03 -0.53 -13.09 -6.45 4E -0.61 -14.63 -7.99 -0.48 -12.16 -5.53 5E 0.61 7.93 14.56 6E -0.43 -11.24 -4.61 x � E t x - nL4 f t IE �,� REI F.RENCE CORNER ,t rr-X COMM tY"-VflN0 DIRECTION 7a ��'WIND DIRECTION Load Case A (Transverse) Load Case B (Longiludinal) Basic Load Cases TSE Engineering Page:q" LATERAL ANALYSIS Job ID: WIND Harman The analysis on the previous page determines the wind force on the total exposed wind surface of the building. For post-frame construction with embedded posts, the amount of wind force imposed on the main force resisting system equals the roof projected area plus 3/8 of the wall projected area. Vt&VI are adjusted by 0,6 for allowable stress values. Calculations that follow adjust the total wind force to the design force on a post-frame building: INPUT: PT= lbs. (non adjusted) PL= lbs. (non adjusted) hr= ft. he = ft. ADJUSTED WIND FORCES: Transverse; VT= [(h.r-0.625 he)/hr](PT)(0.6) = 1393 lbs. Controls Longitudinal; VL_ 1[0.375 he+0.5(hr-he)]/[he+ 0.5(hr-he)]}(PL)(0.6) = 1014 lbs. Controls SEISMIC The seismic force imposed on the main force resisting system of a post-frame building is based on the seismic weight of the roof plus 3/8 of those walls that are perpendicular to the direction of the seismic force. INPUT: Building Width = 22 ft. p= Building Length = 22 ft. 1= SEISMIC WEIGHTS: W roof = 1452 lbs. Wend walls = 686 lbs. W side walls = 528 lbs. SAS= 2/3 Ss = 1.000 Cs = SDS/(R/1) = 0.400 SEISMIC BASE SHEAR: V= Cs W Transverse= 792 lbs. Longitudinal = 855 lbs. SEISMIC DESIGN FORCES: VT= Cs Wt p 0.7= 72.1 lbs. VL= Cs WI p 0.7 = 778 lbs. _ Dn—North Arrow in Circle0 M-4 i'l'I Ij_- f w1t 19.tWitl t.2*I'm isia e03�-3161 ■ ■ ■ ' �. ° �°A000.9552 Building Desig n n..aourrw.:Ph9tu•,sss a•ax•roau�ssta s¢r.tonwcvtrntst .I�cEbookcomlpennablX PLEASE CHECK Wind MPH C}iaoll-up doors fit In Says 'ff�noll-up doors wilt not hit Truss Wind Exposure BOO _L�(1LR6 ol Pltali ea-L Eave Height Snow Load -I-!-Minimum Clearance DENjplease clrcla) FLOOR PLAN r w 4ef Pn� , .11.52 22� ,Q�. Sube 1=1,�•t r� , 3e6 DGYMF wIPAO lit . IOY'T DSR'^ V {J) $Tph oqT LoG-"I4J ALLau 9170 W1 (AA9 S 377nG•O l . .�,r TVT 1 T� I I j_ i_'i cj H I BUI DING ELEVATION ua Culomer has verified and approved the orientation of the building to the Nwib and verifies that all items specified in Paragraph B of the contract amsbown on this drawing and v _ e.. /� - IIIIII IIIII IIII II'I (.uAomer Name j,�/f �F 4f. Lead R: Cualot=SiSoahrto:� "1 L 4J_Y}�1�iY�� J _i • 0 e Whar•CLuoiwtrCaaj - ceez.y-ogee easy 02012 Petma•8st® ps.e3 0/12 11� TSE Engineering Page: SHEARWALL DESIGN Job ID: SIDEWALL Harman B . RIDGE VL ENDWALL A_ 1 1VT 21 PLAN VIEW WITH GRIDS SHEARWALL SHEAR UNIT LENGTH FORCE SHEAR (ft.) (Ibs.) (plf) — ENDWALL GRID 1 696 87 < 116plf allowable for metal clad wall (see page 07 ) ENDWALL GRID 2 11 696 63 .411,6 SIDEWALL GRID A 10 507 SIDEWALL GRID B 22 507 ROOF SHEAR UNIT LENGTH FORCE SHEAR (ft.) (lbs.) (pIq ROOF GRID 1 &GRID 2 23.1 696 4 111 ROOF GRID A& GRID B 22 507 NFBA Poslr+I came Building Design Manual Metal-Clad Wood-Frame Table 7-1.cant.,MCWF Diaphragm Test Assembly Data Test Assemblyhiumber 9 10 Test Configuration Simple Beam Cladding - Type _ Regular Leg I Extended Leg I RegularLeg Extended Le Base Metal Thickness Gauge 29 Major Rib Spacing,inches 9 Maior Rib height,inches 0.62 Major Rib Base Width,inches 1.75 Major Rib Top Width,inches 0.75 Yield Strength,ksi 80 Overall Design Width,feet 36 Length,b,feet 12 Purlin Spacing,feet 2 Rafter Spacing Pair of rafters every 12 feet each pairs aced 6 in.apart) Purlin Location Top running and lapped Inset Purlin length,ft 13.2 and 12.0 11.25 To special blocking nailed between Purlin Attachment each air of rafters To joist Banger attached to rafters Purlin Orientation On edge Number of Internal Seams 11 Wood Properties Purlin Size 2-by 6-inch Purlin Species and Grade No.2 DFL and 1650f DPL Rafter Species and Grade No.2 DFL Stitch Fastener* Type None Screw* None Screw* Length,inches ` ` 1.5 1.5 Diameter #10 #10 On Center Spacing,inches 24 _ 24 Sheet-to-Purlin Fasteners Type Screw Length,inches 1.5 Diameter #10 Location in Field In Flat Location on End In Flat Avg.On-Center Spacing in Field,in. 9 Avg.On—Center Spacing on End,in. 9 Engineering Properties Ultimate Strength,P,,,ib£ 6950 ___ 7850 6400 6950 Allowable Shear Strength,v,„lbf/ft 116 131 107 116 Effective In-Plane Stiffness,c,lbVin _17K 7500 3700 4400 Effective Shear Modulus,G,IbUin 4700 7500 3700 4400 Reference NFBA, 1996 *Because of the extended leg,screws install e in the flat at overlapping seams function as stitch fasteners. Vallow — 116 plf with#10 screws spaced 9"oc 7-8 National Frame Building Association Past-Frame Building Design Manual (fannary 2015) 0 2015.All rights reserved, TSE page: Engineering ��✓✓ EMBEDDED POST DESIGN (POST-FRAW- CONSTRUCTION) Sidewall fx& " Eave Height Post b Post d HF Post Fb Fc EE(10)^6 8 NOMINAL: 4 6 #2 850 1300 1.3 ft. ACTUAL: 3.5 5.5 CD 1.6 1.6 1.0 in. in. CF 1.3 1.1 CL 1 Pay Width Span Roof OH Roof D Roof S Ci 0.8 0.8 0.95 12 22 0 3 25 ft. ft. ft. psf psf Fb' Fc* E'(10)^6 1414 1830 1.235 ASD Wind Pressure 0.75W W Is Iw psi psi psi 10 90 120 1 1 psf plf plf Cs 1 IBC 2015 ASD BASIC LOAD COMBINATIONS: Loading: D + 0.75S+0.75W Loading: D+W P 2871 lbs. P 396lbs. fc 149.1 psi fc 20.6 psi le 76.8 in. le 76.8 in. le/d 14.0 le/d 14.0 KCE 0.3 KCE 0.3 FCE 1900 psi FIDE 1900 psi c 0.8 c 0.8 k.1 1.27 k.1 1.27 k.2 1.30 k.2 1.30 Cp 0.70 Cp 0.70 Fc' 1288 psi Fc' 1288 psi M (in-span) 4860 inAbs. M (in-span) 6480 inAbs. M (base) 8640 inAbs. M (base) 11520 inAbs. S.Mod. 17.65 in^3 S.Mod. 17.65 in^3 fb(in-span) 275 psi fb(in-span) 367 psi fb(base) 490 psi fb (base) 653 psi Post CSI (in-span)= 0.21 Post CSI (in-span)= 0.26 Post CSI (base)= 0.39 Post CSI (base)= 0.47 v 6.9.07 TSE page: Engineering EMBEDDED POST DESIGN (POST-FRAMIE CONSTRUCTION) Endwall f x 6Z Eave Height Post b Post d HF Post Fb Fc E(10)^6 8 NOMINAL: 4 6 #2 850 1300 1.3 ft. ACTUAL: 3.5 5.5 CD 1.6 1.6 1.0 in. in. CIF 1.3 1.1 CI- 1 Av.Spacing Bay Width Roof OH Roof D Roof S Ci 0.8 0.8 0.95 11 12 0 3 25 ft. ft. ft. psf psf Fb' Fc* E' 10 16 1414 1830 1.235 ASD Wind Pressure 0.75W W Is Iw psi psi psi 10 83 110 1 1 psf plf plf Cs 1 IBC 2015 ASD BASIC LOAD COMBINATIONS: Loading: D+ 0.75S_+0.75W Loading: D+W P 1436lbs. P 198lbs. fc 74.6 psi fc 10.3 psi le 76.8 in. le 76.8 in. le/d 14.0 le/d 14.0 KCE 0.3 KCE 0.3 FcE 1900 psi FcE 1900 psi c 0.8 c 0.8 k.1 1.27 k.1 1.27 k.2 1.30 k.2 1.30 Cp 0.70 Cp 0.70 Fc' 1288 psi Fc' 1288 psi M (in-span) 4455 inAbs. M (in-span) 5940 inAbs. M (base) 7920 inAbs. M (base) 10560 in.-lbs. S.Mod. 17.65 inA3 S.Mod. 17.65 inA3 fb(in-span] 252 psi fb (in-span) 337 psi fb(base) 449 psi fb (base) 598 psi Post CSI (in-span)= 0.18 Post CSI (in-span)= 0.24 Post CSI (base)= 0.33 Post CSI (base)= 0.43 v 6.9.07 TSE Engineering Page:/v P= 3696 Ibs Foundation Design ♦ Y Diaphragm Restraint per 2015 IBC Section 1806.3 & 1807.3 (Sidewall Post) w [H(ft)=8 Bay Width (ft)= 12 Wind Load s 10.0 lw= 1 � w(plf)= 120 Lateral Load Design: Post Diameter: 0.54 ft. 0.0 cu yd Foundation Depth: 4 ft. Constrained? YES Depth Required 3.1 ft. Nonconstrained? Soil Passive Allowable: 100 psf Gravity Load Design: DL(psf) = 3 P= 3696 Ibs Snow Load(psf) = 25 Foundation Diameter: 2 ft. Span +overhang(ft)= 22 Foundation Area: 3.1 sf Bay width(ft)= 12 Bearing Allowable(Fbrg): 1500 psf Is= 1 Actual Bearing(fbrg)=P/A= 736 psf Cs= 1 v 10.10,04-5.23.05 TSE Engineering Page: P= 1848 Ibs Foundation Design ♦ Diaphragm Restraint per 2015 IBC Section 1806.3 & 1807.3 (Endwall or Corner Post) w -� H(ft)=8 Ave Post Spacing (ft)= 11 --> / 67 Wind Load (p sfl= 10.0 Iw= 1 1 w(plf)= 110 Lateral Load Design: I Post Diameter: 0.54 ft. 0.0 cu yd Foundation Depth: 4 ft. Constrained? YES Depth Required 2.9 ft. Endwall Nonconstrained? Soil Passive Allowable: 100 psf Corner Post=4' depth Gravity Load Design: DL(psf) = 3 P= 1848 Ibs Snow Load(psf) = 25 Foundation Diameter: 1.5 ft. Bay Width +2x overhang(ft)= 12 Foundation Area: 1.8 sf Ave Post Spacing(ft)= 11 Bearing Al Iowable(Fbrg): 1500 psf Is= 1 Actual Bearing(fbrg)=PIA= 654 psf Cs= 1 v 10,10.04-5,23.05 TSE Page: f Engineering PURLIN INPUT: Uniform Loading Span Length w(DL) w(SL) IS L Roof(psf) 3 25 1.0 11.4 ft 0 Tributary(ft) 2 2 CS= 1.0 Wall (psf) 0 0 Tributary(ft) 0 0 Floor(psf) 0 0 Tributary(ft) 0 0 Other(plf) 0 0 w(TL) 0 6.0 50.0 56.0 0 plf plf plf RESULTS: VI (DL) Vr(DL) VI (LL) Vr(LL) VI (TL) Vr(TL) M (DL) M (LL) M (TL) 34 34 285 285 319 319 97 812 910 lbs. lbs. lbs. lbs. lbs. lbs. ft.lbs. ft.lbs. ft.lbs. DESIGN: MATERIAL Fb x CF Fv Fc(perp) E x 10^6 Manuf.Lbr. CD 1.15 Timber CH 1 Dimen. Lbr. HF#2 1105 75 405 1.3 Cr 1.15 psi psi psi psi Ci 1 b d A S I 1.5 5.5 8.25 7.6 21 in. in. In.A2 in.A3 in.A4 fv= 53 psi Brg.Lgth.= 0.044 ft. CL= 1.000 fb= 1440 psi GL Cv= N/A R= NIA A (DL) = 0.08 in. A (LL) = 0.70 in. A (TL) = 0.79 in. RATIOS OF ACTUAL TO ALLOWABLE RATIOS OF SPAN TO DEFLECTION fv/Fv' = 0.62 L/ 195 for LL> L/180 ok fb/FU = 0.99 L/ 174 for TL> L/120 ok USE 2x6 HF#2 @ 24" oc Table 1604.3 v 3.3.03 TSIE Page: Nngineering Pf= 25 CS= 1.0 1= 1.0 trib width= 6 RAKE BEAM PD= 3 I J. W .I, I_ _I, t � RA RB 1.75 1.75 1.75 1.75 1.75 1.75 L= 10.5 - INPUT: w(DL) plf 26 26 26 26 26 26 w(LL) plf 150 '150 150 150 150 150 w(TL) plf 176 '176 176 176 176 176 P (DL) lbs P (LL) lbs P (TL) lbs 0 0 0 0 0 RESULTS: RA(TL)= 924 lbs. RB(TL)= 924 lbs. VA(TL) = 924 Ibs.(max.) VB(TL) = 924 Ibs.(max.) MA(TL)= 0 ft.lbs. MA-B(TL) = 2426 tt.lbs.(max.) MB(TL)= 0 ft.lbs. A(DL)= B(DL)= 0.025 In. A(DL) _ 0(LL) _ A(LL) = 0.144 In. 0(LL) _ A(TL)= A(TL) = 0.169 In. 0(TL)_ BEAM PROPERTIES: MATERIAL Fb x CF Fv Fc er Ex 10^6 _ Manuf.Lbr. Timber Dimen. Lbr. DFL#2 900 150 625 1.6 psi psi psi psi b d A S I _Bji g, _gLi . CD 1.15 1.5 11.25 16.88 31.6 178.0 0.08 CH 1 in. in. in.^2 in.^3 in.^4 It. Cr 1 Ci 1 STRESSES: fv= 67 psi fv= 67 psi fb = 920 psi RATIOS OF ACTUAL TO ALLOWABLE STRESSES: fv/Fv'= 0.39 fv/ Fv' = 0.39 fb/Fb' = 0.89 RATIOS OF SPAN TO DEFLECTION: L/ 875 for I_L L/ 745 for TL USE 2x12 DFL#2 v 3.3.03 PLUS 2x6 LEDGER TSE Engineering Page: MECHANICAL CONNECTIONS Description of Connection: Truss Block Bolts INPUT: "WW"or "SS" or "B" Connector Main Member Side Member "wM" ? "DS" ? or"L"? Diameter Bend Yield Specie Thickness Dowel Brg Thickness ww DS B 0.75 45 HF 5.625 4.8 1.5 in. ksi in. ksi in. 36 Parallel to Grain Loading Fem = 4.8 ksi RESULTS: Re= 1 Rt= 3.75 YIELD MODE Im, Z= 5063 K(theta) = 1 p= N/A YIELD MODE Is, Z= 2700 cl = 4 c2 = 2 YIELD MODE II, Z= N/A C3= 0 c4= 0 YIELD MODE Illm, Z= N/A C5= 1.6 C6= 1.6 YIELD MODE Ills, Z= 2191 k 1 = 1.254308 k 2 = 1.081666 YIELD MODE IV, Z= 2983 k 3= 1.947457 k= 1.741464 Z= 2191 lbs. ,See 1)4 ivy TSE Engineering Page: I MULTIPLE BOLT CONNECTIONS Description of Connection: Truss Block Bolts PARALLEL TO GRAIN LOADING GEOMETRY FACTOR Bolt Diameter= 075 in. Bolts per Row= 1 Number of Rows= 2 Ca Row Spacing = 3 in. >=1.5D, o.k. Edge Distance= 1.25 in. >=1.5D, o.k. Bolt Spacing = 6 in, >=3D o.k. 1.000 End Spacing = 6 in. >=3.5D, o.k. 1.000 T or C Connection ? T CA = 1.000 GROUP ACTION FACTOR Ern = 1 A x10^6 psi Am = 19.25 in^2 EmAm = 26950000 Es= 1.4 x10^6 psi As = 16.5 inA2 EsAs= 23100000 Ren= 0.857143 y= 116913.4 u = 1.028198 m = 0.789051 Cg= 1.000 LOAD DURATION FACTOR CD= 1.15 PENETRATION DEPTH FACTOR p = N/A Cd = 1.000 TRUSS REACTION: Snow= 25 P= 3696 OK 1= 1 Cs= 1 0.73 Span= 22 DL= 3 Bay= 12 OH= 0 CONNECTION ALLOWABLE FORC Z' = Z Co Cg CD * Cd * Qty. 2191 0/ 1,000 1.000 1.15 1.000 2 Allowable Z'= 5039 lbs. ��s Property Scan http://dave.snohd.org/PropertyScan.aspx?path=/006213/&id=00621300007500-1.png f(LLPNASE bRAINFIELD 2?b06 -B4�3 NE ORANITE`FALLS, WA �oNcR6r6 t 3roo1 Gq I-SY 9� 9A2SZ ®`SLAB 3-IC-4G SLAL6. f'RaR3S6D RESERVE pREl9 FoR: ,JicK MslmtJA ` rAY No. 67,13-06-0-04S-Oo00 /Ld•oo' ST AT I I �I N SNEb I I, W/HbTivs Q CtdIROMM W � PREJfbuS � si � k I PRvoosE� � l I I I n�f�Ewf�y , - - —_ 53 N ORIGINAL DR►SINFIELD D6sIGNER• RYA TAIJN6R I-13-L9 .TAJsrz�L.LER R►1Y T/LL_ET GO �/-L3—G9 RESERVE REC,Zu1REnnE�175: yso r�S loo l 20 � �ncu..,64e� D�+%rfe%D fh'ea Resv�e S-�O 9f TdT?9L- oR 28S UN �IR FCC Permit#1546 Address Payment Info Address 17823 31 ST DR NE Receipt# 1206717 City ARLINGTON Date 7/14/2017 State WA Paid By Permabilt Industries, Inc. Zip 98223-7758 Description Payment Type Check#20560 Accepted By Kristin Foster Fees Paid Total Amount Fee Fee Description Factor Fee paid Amount Building Plan Review Fee 345.83.00.00 0 269.17 269.17 Total Payment:269.17 Permit Information Date 7/14/2017 Permit Number 1546 Project Name Medina Applicant Name Town and Country Post Frame Xdg. Applicant Address 16521 Hwy 99#C City,State,Zip Lynnwood,WA 98037 Contact Theresa Umbaugh Phone 425-743-1555 Email permit rm ilt Permit Type R idential ss trAIN Site Addre 1 3 31 st riv E val t n 796 0 AtatuN A lied Pe it Is ed ` rmi xpir uar Feet 484 Type of Construc ' n/ cup cy Load Stories 1 —Nt—oposed Use Accessory Structure Assigned To Kristin Foster Property Information Owner Information Parcel#:00621300007500 MEDINA NICK&MARIA MEDINA NICK&MARIA 17823 31ST DR NE 17823 31ST DR NE ARLINGTON,WA 98223 Contractors Contractor Name Primary Phone Email Contractor License License# Contact Type OWN&COUNTRY POST Jeremy 425-743- I abor& FRAME BUILDINGS Hammar 1555 permits@permabilt.co CONTRACTOR Industries TOWNCPF099L Review Date Type Description Tar et Date Completed Date I Assigned To Status 7/14/2017 IlResidential Accessory Structure 7/21/2017 lRick Karns 11in Review 7/14/2017 lResidential Accessory Structure 7/21/2017 1 11SIova Heaton Illn Review Fees Fee Description Notes Amount Building Plan Review Feel 345.83,00,01 1 $269,17 Totall $269.1 Payments Date Paid By Amount I Descri tion Payment Type Accepted ted By 7/14/2017 IlPermabilt Industries, Inc. $269.171 lCheck#20560 jKristin Foster Totall $269.171 Amount Outstanding:$0.0 Notes Date Note 7/14/2017 Snohomish County Health District approval has been applied for Uploaded Files Upload File Date File Uploaded B 7/14/2017 2:15:06 PM 1546 Structurals.pdf Foster.Kristin x 7/14/2017 2:15:06 PM 1546 Site Plan.pdf Foster,Kristin x 7/14/2017 2:15:06 PM 1546 Plans.pdf Foster,Kristin x 7/14/2017 2:15:06 PM 1546 Application.pdf Foster,Kristin X 7/14/2017 2:15:06 PM i 17823 31 st Drive NE Plan Review Receipt.pdf Foster,Kristin x 7/14/2017 2:15706 PM 117823 31 st Drive NE Drainfleld. f Foster,Kristin x A A n ,S J .Y RESIDENTIAL ZONING VERIFICATION APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223 • Phone(360)403-3551 (Please allow 72 hours for review) Project Address: 17823 31st Dr NE, Arlington, WA 98223 plat: Owner/Applicant: Theresa @ Town & Country Post Frame Bldg for David Maria Harmon Address: 16521 Hwy 99 #C City: Lynnwood State: WA Zip Code: 98037 Phone: 425-743-1555 mail: permits@permabi1t.com Describe Proposal (include cross street): Construct detached, post-frame, workshop, shell only, 221x22 ' with 8 ' eave height. Existing gravel access off 31st Dr. NE, cross street 179th St NE. Please check one: ❑ Single-family dwelling El Duplex ❑ Addition El Accessory structure 1. Proposed Dimensions: W) 221 L) 221 H) 11.6 ' Total SF) 484sf 2. Allowed Lot Coverage: Total Lot Size 10, 019 SF x 35% = 3507 SF NaN 3. Actual Lot Coverage: (SF of all structures') 2502 10, 019 (lot size) = 25 0 % (Structures only) 4. Septic Tank? ZJYes UNo Private Well on Site? LlYes U No If so,please provide Snohomish County Health Departmentapproval and indicate on site plan. 5. How many trees greater than 12"diameter will be removed? NSA if any, please indicate on site plan. 6. Appliances permanently connected to water service may require Cross-Connection-Control. (Check all that appl}j �i Fire Sprinkler System Medical Equipment Lawn Sprinkler System L�� Livestock Drinking Tanks �( Decorative Pond/Fountain �'I Hot Tub Re-circulating Heating System Swimming Pool Other Applicant Signatur Date: 6-19-17 This square footage should include t e footpri !ar of all structures on the property including:house,garages, sheds,covered patios,and decks permitted by the building code. Rev 0412013 «. � i ,r;i I 1 I Y, RESIDENTIAL PERMIT APPLICATION Department of Community & Economic Development �►��,�TC`O City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 - Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE, ADDITION, DECK,OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF CONSTRUCTION DRAWINGS AND TWO(2) SETS OF STRUCTURAL CALCULATIONS. THE APPLICATION MUST ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS. THE ZONING VERIFICATION MAY BE SUBMITTED PRIOR. Project Address: 17823 31st Dr NE, Arlington, WA 98223 Plat: ❑ Single-family ❑ Duplex Q' Townhouse Addition CJ Accessory structure Proposed Area: 1s` Floor: 2"d Floor: Garage: 484sf Total SF: 484sf Describe Proposal (include crass street): Construct detached, post-frame workshop shell only, 22 ' x 22 ' with 8 ' eave height. Existing gravel access off 31st Dr. NE, cross street 179th St NE. Valuation: $17, 962 owner: Nick and Maria MedinaZPWl D * rnkt&P� 0d?_M0tQ Address: 17823 31st Dr. NE City: Arlington State: WA Zip Code: 98223 Phone: 425-876-5369 Email: Applicant: Theresa @ Town & Country Post Frame Bldgs Address: 16521 Hwy 99 #C City: Lynnwood State: WA Zip Cade: 98037 Phone: 425-743-1555 Email: permits@permabilt.com Contractor: Town & Country Post Frame Bldgs Address: 16521 Hwy 99 #C City: Lynnwood State: WA Zip Code: 98037 425-743-1555 Phone: Email: permits@permabilt.com Contact Person: Theresa License Number: TOWNCPF099LT Expiration: 6/30/19 6116LP Page 1 of 3 ♦ � � � a RESIDENTIAL PERMIT APPLICATION • • Department of Community & Economic Development City of Arlington• 18204 59th Ave NE -Arlington, WA 98223 - Phone(360)403-3551 Plumbing Section (continue filling out if plumbing is involved} (Check all that apply and indicate the number of fixtures proposed) n/a - if plumbing, owner to obtain ❑ Bath/Shower Combo (4.0) x ❑ Sink (1.5) x Shower (2.0) x ❑ Lavatory (1.0) x ❑. Clothes Washer (4.0) x ❑ Water Closet(2.5) x Dishwasher (1.5) x Water Heater x ❑ Hose Bibb(2.5) x Water Heater Model # ❑ Other (list) x Plumbing Section Continued Proposed Water Piping Size: Proposed DWV Material: Proposed Piping Material: Proposed DWV Size: • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) 6116LP Page 2 of 3 RESIDENTIAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 1NC' Mechanical Section (continue filling out if mechanical equipment is involved) Select proposed appliances: n/a U Furnace(80+) Model # AFUE U Heat Pump Model# SEER HSPE AC Unit Model# SEER Type II Hood Commercial Cooking Appliance Hydronic Piping Boiler Solid-Fuel Appliance PV System Fireplace Insert Outdoor BBQ U Storage Tank �1 Freestanding Stove Gas Piping Other Gas Piping information Not Applicable: Pipe Material: . Pipe Size: Total BTU's of all Appliances: Distance from Meter to Furthest Appliance: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps(drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper combustion air and venting required for all appliances • A shut-off is required within 6 feet of all appliances Applicant Signature: IEUZ� Date: 6-19-1 7 Print Applicants Name: Ul 6/16LP Page 3 of 3 Date: 03/18/2026 Permit#: 1546 Permit Date: 07/14/2017 Review Date: 07/14/2017 Permit Type: ACCESSORY STRUCTURE Review Type: ASSESSORY STRUCTURE Target Date: 07/21/2017 Scheduled 00:00 Time: Completed 08/01/2017 Date: Description: Drainage needs to be addressed if project triggers thresholds for drainage. The area shown as existing gravel drive was a planter as of 8/2014. Was this a permitted improvement?Was drainage for the driveway addressed? Provide some clean rock infiltration for the roof drainage. Review Status: Assigned To: Nova Heaton Time In: 00:00 Time Out: 00:00 Hours: 0.0 Property Information Parcel#: 00621300007500 MEDINA NICK& MARIA MEDINA NICK&MARIA 17823 31 ST DR NE 17823 31 ST DR NE ARLINGTON, WA 98223 Zoning: I I I Single Family Residence - DetachedLot: Block: Permit#: 1546 Permit Date: 07/14/17 Permit Type: ACCESSORY STRUCTURE Project Name: Medina Applicant Name: Town and Country Post Frame Bldg. Applicant Address: 16521 Hwy 99 #C Applicant, City, State, Zip: Lynnwood, WA 98037 Contact: Theresa Umbaugh Phone: 425-743-1555 Email: permits@permabilt.com Scope of Work: Accessory Structure Valuation: 17962.00 Square Feet: 484 Number of Stories: 1 Construction Type: Occupancy Group: ID Code: Permit Issued: Permit Expires: Form Permit Type: Status: VOID/WITHDRAWN Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00621300007500 17823 31 ST DR NE MEDINA NICK& 111 Single Family MARIA Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# TOWN&COUNTRY POST FRAME 425-743-1555 16521 HWY 99 CONSTRUCTION UBI 600 461 076 BUILDINGS #C CONTRACTOR TOWN&COUNTRY 16521 HWY 99 CONSTRUCTION Labor& POST FRAME 425-743-1555 TOWNCPF099LT BUILDINGS #C CONTRACTOR Industries Plan Reviews Date Review Type Description Assigned To Review Status 07/14/2017 ASSESSORY STRUCTURE z.Rick Karns Drainage needs to be addressed if project triggers thresholds for drainage.The area shown as existing gravel 07/14/2017 ASSESSORY STRUCTURE drive was a planter as of 8/2014.Was this a permitted Nova Heaton improvement?Was drainage for the driveway addressed? Provide some clean rock infiltration for the roof drainage. Fees Fee Description Notes Amount Building Plan Review Table 4-2 $269.17 Total $269.17 Payments Date Paid By Description Payment Type Accepted By Amount 07/14/2017 Permabilt Industries,Inc. Check 420560 Kristin Foster $269.17 Outstanding Balance $0.00 Notes Date Note Created By: 10/13/2017 Applicant has withdrawn submittal due to Health Department denial.KF Kristin Foster Do not issue until the Health Department approves.At this time the Health Department has 08/23/2017 denied the application requesting revisions.See the uploaded Health Department letter for more Kristin Foster info.KF 07/14/2017 Snohomish County Health District approval has been applied for. Kristin Foster Uploaded Files Date File Name 08/23/2017 2551374-1546 8-23-2017 Health Department Letter.pdf 07/14/2017 2447906-17823 31st Drive NE Drainfield.pdf 07/14/2017 2447907-17823 31st Drive NE Plan Review Receipt.pdf 07/14/2017 2447908-1546 Application.pdf 07/14/2017 2447909-1546 Plans.pdf 07/14/2017 2447910-1546 Site Plan.pdf 07/14/2017 2447911-1546 Structurals.pdf