Loading...
HomeMy WebLinkAbout17901 33rd Ave Ne_BLD1518_2026 CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address: 17901 33rd Avenue NE Permit#: 1518 Parcel#:00621300006200 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:BENNETT JEAN L Name:Brennan Heating Name:Brennan Heating Address: 17901 33RD AVE NE Address:4601 S 134th Place Address:4601 S 134th Place City,State Zip:ARLINGTON,WA 98223 City,State Zip:Seattle,WA 98168 City,State Zip:Seattle,WA 98168 Phone: Phone:206-248-7900 Phone:206-248-7900 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Brennan Heating Name: Address:4601 S 134th Place Address: City,State,Zip:Seattle,WA 98168 City,State,Zip: Phone:206-248-7900 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: I OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR 111S/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL O CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRCI 10. Iles tax relating to construction and construction materials in the City of 1' t must be reported on your sales tax return form nd coded City o rlington#3101 Signature Print Name Date Released By Datc CONDITIONS Approved unit- Lennox XC 13-024 2 ton AC Unit- 13 SEER......3" CONCRETE PAD WITH SEISMIC BRACING ATTACHED TO PAD; ELECTRICAL DISCONNECT REQUIRED; LINES SHALL BE INSULATED, USE OF ADHESIVE TAPE IS NOT PERMITTED. THIS PERMIT AUTIIORIZS ONLY TITS WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,FTC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 6/16/2017 A/C Unit $25.00 6/16/2017 Building Permit Fee $25.00 6/16/2017 Processing/Technology Fee $25.00 Total Due: S75.00 Total Payment: $75.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following Information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 ` PHONE; (360) 403-3551 BUILDING PERMIT Address: 17901 33rd Avenue NE Permit#• 1518 Parcel#:00621300006200 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:BENNETT JEAN L Name:Brennan Heating Name:Brennan Heating Address: 17901 33RD AVE NE Address:4601 S 134th Place Address:4601 S 134th Place City,State Zip:ARLINGTON,WA 98223 City,State Zip:Seattle,WA 98168 City,State Zip:Seattle,WA 98168 Phone: Phone:206-248-7900 Phone:206-248-7900 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Brennan Heating Name: Address:4601 S 134th Place Address: City,State,Zip:Seattle,WA 98168 City,State,Zip: Phone:206-248-7900 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: I OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of I' t must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date V Released By Date CONDITIONS Approved unit- Lennox XC 13-024 2 ton AC Unit- 13 SEER......3" CONCRETE PAD WITH SEISMIC BRACING ATTACHED TO PAD; ELECTRICAL DISCONNECT REQUIRED; LINES SHALL BE INSULATED, USE OF ADHESIVE TAPE IS NOT PERMITTED. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 6/16/2017 A/C Unit $25.00 6/16/2017 Building Permit Fee $25.00 6/16/2017 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $75.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON 238 N.OLYMPIC AVE-ARLINGTON,WA.98223 1'1IONE;(360)403-3551 BUILDING PERMIT Addrese 17901 33rd Mrn ue NE farmit n:1518 Pmcel w'X)Q1360'k16200 \'al wtliun'0.ro OWNER APPLICANT CONTRACTOR Name.BENNETT JEAN L N:mm Bi nu.n,H-Ixg Name.Brcnn:ut l lc:ninc Addrese 17901 33RD AVE NE Add—,11d,1 S I I11h N.— Address.4601 S 134th Pla.:e (ltvt Stale Zip:ARLINGTON.WA 9S223 (q.Stem Zip-Seettic.\\.\"S 164 City.State Zip:Seattic,WA 98168 Ph— Ph,— 206-24F7wS) Phone:206.249.7900 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR NaI—Brennan lleatmg N.unc. Addrcas:4601 S 134th Plan City,Smte,Zip:Seattle,WA 9816S lln,va:c.Z,P Phacc:206-248•7900 I`h nu JOB DESCRIPTION PIR\HT TYPF Residential Mechanical cODF.S FAR 2015 STORIES: CONST.TYPE: DWELLING UNITS: I-REVISED PERMIT OCC GROUP: BUILDINGS: I OCC LOAD. PERMIT APPROVAL 1 AGREL TO COMPLY WITII CITY AND STATE LAWS REGULATING CONSTRUCTION AND IS DOING TI IL WORK AL TI!ORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO W'ORKMEN`S COMP ' TION INSURANCE AND RCW 19.27. TI I PL ATION IS NOT A PERMIT UNTIL SIGNED BY TIIE BUILDING OFFICIAL OR HISMER DEPUTY AND ALL FINS ARE PAID. IS UNLA FUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS DEC•\MADE AND APPROVAL OR ACERTIFI ATEOFOCCUPANCY IIASBELN GRANTED.IBCllfl'IRC'lln, •Sala mx rcla 1tF m ennctmetmn and omstruainn materm s In the Cin of Atli gmo mu be repvtrd nn yom sales tax rcttun fnnn and c .nriingtnn 9310r 1 S,gnaturc Pant V,nm I1atc <Im<.a Hy Dam CONDITIONS REVISED PERMIT Lennox MPA018S4S-IP-23.50 SEER-HSPF 10.5;Interior Unit MWMA018S4-3" CONCRETE.PAD WITH SEISMIC BRACING ATTACHED TO PAD;ALL I-INES SHALL BE INSULATED,USE OF ADHESIVE TAPE IS NOT PERMITTED,ELECTRICAL DISCONNECT REQUIRED PHIS PERMIT AUTHORIZS ONLY THE WORK NO"rED.'I'HIS I'MMITCOVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON TI IE PUIILIC IR)MAIN(CURIIS,SIDEWALKS.DRI VBWAYS.MARQUEES.ETC.)WILL REQUIRE SEPARATE.PERMISSION" PERMIT FEES Date Description Fee Amount 8170017 A/C Unit S25.00 8/7I2017 Building Permit Fee S25.00 8f72017 Processing/Technology Fee S25.00 Total Due: S75.00 Total Payment: S75.00 Balance Dua $0.00 CALL FOR INSPECTIONS IItILIFING(360)403-3417 %%'he calling fur an inspection please lease the following iorormalion: Permit N..... I .I'vpc of Insprction hying requested.and whether you prefer morning or afternoon CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 _ IF BUILDING PERMIT Address:17901 33rd Avenue NE Permit#:1518 Parcel#:00621300006200 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:BENNETT JEAN L Name:Brennan Heating Name:Brennan Heating Address: 17901 33RD AVE NE Address:4601 S 134th Place Address:4601 S 134th Place City,State Zip:ARLINGTON,WA 98223 City,State Zip:Seattle,WA 98168 City,State Zip:Seattle,WA 98168 Phone: Phone:206-248-7900 Phone:206-248-7900 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Brennan Heating Name: Address:4601 S 134th Place Address: City,State,Zip:Seattle,WA 98168 City,State,Zip: Phone:206-248-7900 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: I - REVISED PERMIT OCC GROUP: BUILDINGS: 1 OCC LOAD: _ PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Released By Datc - CONDITIONS =1 REVISED PERMIT Lennox MPA018S4S-lP - 23.50 SEER- HSPF 10.5; Interior Unit MWMA018S4 - 3" CONCRETE PAD WITH SEISMIC BRACING ATTACHED TO PAD; ALL LINES SHALL BE INSULATED, USE OF ADHESIVE TAPE IS NOT PERMITTED; ELECTRICAL DISCONNECT REQUIRED THIS PERMIT AUTHORIZE ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 8/7/2017 A/C Unit $25.00 8/7/2017 Building Permit Fee $25.00 8/7/2017 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $75.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon ~1 CITY OF ARLINGTON 239 N. OLYMPIC AVE-ARLINGTON, WA. 98223 III IONS; (360)403-3551 BUILDING PERMIT Addresc: 17901 J.3rd,wcnu NE Permit N Permit M:1519 Parcel v:0O6213(H)w'20i1 Valwi ion:0 00 OWNER APPLICANT CONTRACTOR Nance:111:NNE"FT JIiAN I. Name Brennan Ileatmg Name,13rcnriart Healing Address: 11901 _33RD AVV\I: Address:4601 S 134111 Place Address,4601 S 13-Ith Place City.Statc"lip:ARLIN(1TON,WA 9822.1 C'il+y,State lip:Seattle.WA 9816H City,Statc Zip:Seattle,WA 98 168 phone: phone:200-24R-7960 Phone:21R•24S-7901) MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Namc:Urcanan Ileating Name Addre,,:41,01 S 1341h Place Acblress• COy,Statc.Zip:Scaulc.WA 9S16S City.state.Lip Phocc,2(If-248-7•)I10 Pkbn:c: LIC 1�Yp I IC a: F;xP. YOB DESCRIPTION PrIMIT rypl- Residential Mechanical CI)Dl;YF•.AR 2015 SMRIES. CONST TYPE. DWLLLINGUNITS. I - REXISED PERMIT 00161401'1, BUILDINGS I 0CC LOAD PF,R11tIIT APPROVAL \GRIsi:TO COMPLY WFTII CITY-AND S L\I-L LAWS RLG1.1..\tING C ONS FR' ('F►i)N AND IN 1SOINI 'Illi X'U1cK At,usvnr..a.. ••••••-••• IY- NO PERSON W ILI-111:i:NiPLOYED IN V10LATION 01' TI11'.LABOR COD OF TI1E STATE Or WASl11NGTON RHL%TING TO W ORKNIEN'S cuNtpk:' \110N INSURANCE AND R('W 13.27- TTI '*Rk L AI'ION IS N l)f A T'LRMIT UNTII.S!(iNI:U[lY Tl ll".C3UILDIN(;UF' ' vL OR I IISAIIiR Dl I'UTY:AND AEI.ELLS ARL PAIDTO t;SE OR OCCUPY A[It1LDIN[,OR STRU(`TURE UN- INSPECTIONilAS[3ELNN1ADI:ANDAPPRON:'1L.OR F`(1('C.`UP.ANCI'I IAS nIiI!N(iRAN'I'I:D 1aC110,11WI), ('' ti:dr.the rel,n t us cnnamcunn and am tntct;o, •(ou mu he rePwled n Al s return,amt itingoin'1110ra► r cedny [)ate rc Print Nanic ,.,1-..- - -. ._.. . REVISED PERMIT Lennox MPA01 KS4S-IP - : . nit�=IA018S4 - 3" CONCRETE PAD WITH SEISMIC BRACING- LIMES SHALL, BE INSULATI'D, USE.OF ADFIhSIVE: TAPE IS NO• RICAL DISCONNECT REQUIRt-, I HIS PER;�II't Ali 1'i101(1/S UNI_Y I l lh WORK No FI) IHN I'LNV1l I- O CVERS WORK J.A"II'RUPFRI'Y ONLY, ANY COV51'RUC PION ON T'IIF.1'11111A DI(MAIN(('I:IMS,SIDEWALKS,DR1VFWAYS,MAR(1t11ir <i'OUIRE SF.PARATI:PERMISSION. •7I'7n�I:iT�•.—tl."l•..:I.,.. Jii�^--Tr',.4.I:: 'i -._i ..tt'.. .... PERMIT FEES •`e Amount irnt Date Description $25.00 81712017 A1C Unit $25,00 B17f2017 Building Permit Fee $25.00 817/2017 Processing(Technology Fee �);00 Total Due: Tolal Payment: S75.00 Balance Due: 30.00 CALL FOR.INSPRCTIONS "'hen callinr for an inspection please leave the following information: Per nr11 Vuwbrr, Pypr"f Irnprctlun briny rrstn(•slrd,and whelhrr you niny or afternoon prefer inor _ • r.• �''. � .. RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 182011 59th Ave NE •Arlington,WA 98223 • Piione(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: Project Description: pom_f Owner: —�1Y�'� --- ---- Address: Phone: �a J `1 Email: -- - - - Applicant: Brennan Heating Address: 4601 S 134th P eattle 98168 __ ----Phone: - 206-248-790 Email: Jaimie@brennanheating.com _------------------` Applicant Signature - Electronic Signature if submitting on-line I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. CONTRACTOR INFORMATION Contractor Name:Brennan Heating ---- Company: Brennan Heating License Number:BRENNHA971 R9 Expiration: 1 22/29 � bl� Phone:206-248-7900 Email:Jai mie@brennanheating.corn STAFF USE ONLY Permit #: ( �" Accepted by: Date: 1 - RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE •Arlington. WA 98223 •Phone(360)403-3551 SELECT ALL PROPOSED APPLIANCES ❑ Furnace (80+) Fireplace Insert [� Outdoor BBQ Heat Pump ❑ Freestanding C �C�I..eSS� g Stove ❑ Hydronic Piping ❑ Type II Hood [� Commercial CookingAppliance PP liance ❑ PV System ❑ Boiler ❑ Gas Piping g ❑ Storage Tank ❑ AC Unit ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: Pipe Material: Pipe Size: Distance From Meter to Furthest Appliance Total BTU's of all Appliances: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips)are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances ,.,• 4�7 SPECIFICATIONS MPA OUTDOOR UNITS 0.7S -LS TON Nominal Size-Tons 0.75 1 1.5 Outdoor Unit Model No. MPA009S4S MPA012S4S MPA018S4S Ambient Temperature Cooling 5-122 5-122 5-122 Operating Range-°F —13-86 —13-86 Heating —13-86 Sound Data Cooling(115V) 51 52 - (dBA) Cooling(208/230V) 53 54 61 Heating(115V) 54 54 ' Heating (208/230V) 55 57 62 Refrigerant Charge furnished(R-410A) 2 lbs. 12 oz. 2 lbs. 12 oz. 4 lbs.3 oz. Maximum line length with furnished charge-ft. 25 25 25 Additional charge required per ft.-oz. 0.16 0.16 0.16 Compressor No.and Type (1)Rotary (1)Rotary (1)Rotary Refrigerant oil type Ester Oil VG74 Ester Oil VG74 Ester Oil VG74 Refrigerant oil charge-oz. 12.5 12.5 15.2 Low ambient cut-off —13°F —13°F —13°F Connections-in. Liquid/Gas pipe(flare) 1!4 1318 1/4/ 1/2 1/4/1/2 Maximum refrigerant pipe length-ft. 98 98 98 Max.difference in level of indoor unit-ft. 40 40 66 Outdoor (No.)Diameter-in. (1)-16.5 (1)- 16.5 (1)-18 Fan 1180 --- Total air volume-cfm(115V) 1180 Total air volume-cfm(208/230V) 1120 1180 1470 rpm(115V) 850 850 --- rpm (208/230V) 800 800 800 Outdoor Coil Number of rows 2 2 3 Fins per inch 21 21 18 Fin type Hydrophilic aluminium Tube outside diameter-in. 1/4 1/4 114 Tube type Rifled copper tubing Net face area-ft.2 4.72 4.72 5.42 Design Pressure PSIG 550/340 550/340 550/340 Shipping Data Net/Shipping weight(lbs.) 83 188 83/88 111 / 120 ELECTRICAL DATA, Electrical Characteristics 60 Hz-1 Phase 115V 208/230V 115V 208/230V 2081230V Maximum Overcurrent Protection (amps) 20 15 20 15 20 Minimum circuit ampacity 15 15 15 15 15 Compressor Rated load amps 9 5.3 10 5.7 9.5 Outdoor Fan Rated load amps 0.6 0.42 0.6 0.42 0.5 Motor Output-W 40 40 40 40 50 NOTE-Extremes of operating range are plus and minus 10%of line voltage HACR type circuit breaker or fuse. Refer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. Single Zone Mini-Split Systems I Page 14 SPECIFICATIONS-WALL-MOUNTED INDOOR UNITS Model No. MWMA009S4 MWMA009S4 MWMA012S4 MWMA012S4 Nominal Tons 0.75 0.75 1 1 Power Supply-60 hz-1 phase 115V 208l230V 115V 208/230V Rated load amps 0.25 0.06 0.4 0.06 Output(W) 20 20 Room Temperature 20 20 Range(7) Cooling 62-90 62-90 62-90 62-90 Heating 32-86 32-86 Air Volume-cfm(High/Medium/Low 32-86 32-86 365/265/195 370/270/195 365/265/195 370/275/200 Sound Data (dBA)-Low/Medium/High 24/33/42 Piping Connections-Liquid/Gas-o.d.-flare-in. 1/4/3/8 _ 26.5/33.4/41.7 24/33/42 28.6/35.8/45.1 1/4!3l8 1/4/3/8 1/4/1/2 1/4 11/2 Drain connection o.d.-in. 1 1 1 1 Net/Shipping weights-lbs. 20/2g MOUNTED 126 20/2s 20/27 SPECIFICATIONS ALL- OOR UNITS 0 e 18S4 MWMA024S4 MWMA030S4 Nominal Tons 2 2.5 Power Si apply-60 hz- 1 phase 208/230V 208/230V 208l230V Rated load amps 0.13 0.3 0.5 Output(W) 58 60 Room Temperature 60 Range(°F) Cooling 62-90 62-90 62-90 Heating 32-86 32-86 32-86 Air Volume-cfm(High/Medium/Low) 530/410/295 695/625/485 795/645/500 Sound Data(dBA)-Low/Medium/High 30.9/36.3/46.2 35.1/44.5/51.7 37.5/42/49 Piping Connections-Liquid/Gas-o.d.-flare-in. 1/4/1/2 3/8/5/8 3/8/5/8 Drain connection o.d.-in. 1 1 1 Total refrigerant pipe length-ft. gg 98 164 Net/Shipping weights-lbs. 27/35 40/54 40/51 " f Single Zone Mini-Split Systems/Page 16 '� Property Owners Name: Assessor's parcel Site Address: Sits Plan North R+D � c end: �-•pf%xny tine _Building pedmeta Map Scale 1 (inl 20'(M I��'7 14N 16vN 1. MPAOM sws.Ile POMP Scanned by CamScanner i i II i CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:17901 33rd Avenue NE Permit#:1518 Parcel#:00621300006200 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:BENNETT JEAN L Name:Brennan Heating Name:Brennan Heating Address: 17901 33RD AVE NE Address:4601 S 134th Place Address:4601 S 134th Place City,State Zip:ARLINGTON,WA 98223 City,State Zip:Seattle,WA 98168 City,State Zip:Sealtle,WA 98168 Phone: Phone:206-248-7900 Phone:206-248-7900 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Brennan Heating Name: Address:4601 S 134th Place Address: City,State,Zip:Seattle,WA 98168 City,State,Zip; Phone:206-248-7900 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING TIIF:WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF Ti IE STATE OF WASHINGTON RELAI'ING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 19,27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR IIIS/HER DEPUTY AND ALL FEES ARE.PAID. IT IS UNLAWFUL TO USE OROCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL U CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED, IBCI 10/IRCI I0. des tax relating to construction and construction materials in the City of A I' t must be reported on y°or sales tax return form tnd coded Cityof r rlington 41101 J1�0/1 Signature Print Name Date Released By ato CONDITIONS Approved unit- Lennox XC 13-024 2 ton AC Unit- 13 SEER......3" CONCRETE PAD WITH SEISMIC BRACING ATTACHED TO PAD; ELECTRICAL DISCONNECT REQUIRED; LINES SHALL BE INSULATED, USE OF ADHESIVE TAPE IS NOT PERMITTED. THIS PERMIT AUTIIORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK'rO BE DONE ON PRIVATE.PROPwrY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES, ETC.)WILL REQUIRE SEPARATE PERMISSION, PERMIT FEES Date Description Fee Amount 6/16/2017 A/C Unit $25.00 6/1612017 $25.00 Building Permit Fee 6/16/2017 Processing/Technology Fee $25.00 Total Due: 575.00 Total Payment: S75.0U Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following Information: Permit Number,Type or Inspection being requested,and whether you prefer morning or afternoon I ��� I CITY OF ARLINGTON 0 � 238 N. OLYMPIC AVE -ARLINGTON,WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address: 17901 33rd Avenue NE Permit#:1518Valuation:0.00 Parcel#:00621300006200 OWNER APPLICANT CONTRACTOR Name:BENNETT JEAN L Name:Brennan Heating Name:Brennan Heating Address: 17901 33RD AVE NE Address:4601 S 134th Place Address:4601 S 134th Place City,State Zip:ARLINGTON,WA 98223 City,State Zip:Seattle,WA 98168 City,State Zip:Seattle,WA 98168 Phone: Phone:206-248-7900 Phone:206_248-7900 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Brennan Heating Name: Address:4601 S 134th Place Address: City,State,Zip:Seattle,WA 98168 City,State,Zip: Phone:206-248-7900 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AU t tiORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BU ILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of 1* t must be reported on your sales tax return form and coded City of Arlington#3101. _ Signature Print Name Date Released By Date CONDITIONS Approved unit- Lennox XC 13-024 2 ton AC Unit- 13 SEER...... 3" CONCRETE PAD WITH t H SEISMIC BRACING ATTACHED TO PAD; ELECTRICAL DISCONNECT REQUIRED; LINES SHALL BE INSULATED, USE OF ADHESIVE TAPE IS NOT PERMITTED. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Fee Amount Date Description $25.00 6/16/2017 A/C Unit $25.00 6/16/2017 Building Permit Fee $25.00 6/16/2017 Processing/Technology Fee Total Due: $75.00 Total Payment: $75.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of inspection being requested..and%N hether you prefer morning or afternoon i W 1 Asighk RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington,WA 98223 • Phone (360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: f'lgOl _?2?2rJ QrV_e N_t— ra 000:90 49a� Project Description: I rli �� ��p� F�C��11'lt�—_-_-- -- Owner: 3C6I>» Address: I"Zcf I r Phone: _4-2.S . c5C)1_ j3 t4 Email: --� Applicant: Brennan Heating Address: 4601 S 134th PI Seattle 98168 Phone: 206-248-7900 Email: Jaimie@brennanheating.com _ Applicant Signature: ----- Electronic Signature if submitting on-line I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. CONTRACTOR INFORMATION Contractor Name:Brennan Heating ---- - Company: Brennan Heating License Number:BRENNHA971 R9 Expiration: 12/29_`�-- Phone:206-248-7900 Email:Jaimie@brennanheating.com STAFF USE O LY Received Date: Permit#: Accepted hy: _ __ -1t)t� -r- Zmfi i �� i� ��� i i �+ RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington• 18204 59th Ave NE• Arlington,wA 99223 ' r'Iiww (360)403-3551 SELECT ALL PROPOSED APPLIANCES ❑ Furnace (80+) ❑ Fireplace Insert ❑ Outdoor BBQ ❑ Heat Pump ❑ Freestanding Stove ❑ Hydronic Piping ❑ Type II Hood ❑ Commercial Cooking Appliance ❑ PV System ❑ Boiler ❑ Gas Piping ❑ Storage Tank AC Unit ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: Pipe Material. Pipe Size: Distance From Meter to Furthest Appliance; Total BTU's of all Appliances: New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances i� it i� i+ ASscssor�s:pa Property Owners Name: parcel 8'Z2 - Site Address: y Site Plan North rnd... nter LEN✓ im Mp c20'(n) l,e- (,W$ o' F! �0r Scanned by CamScanner Y,�. 1 I I 'SPECIFICATIONS General Model No. North Region XC13NO18 XC13NO24 XC13NO30 XC13NO36 XC13NO42 XC13NO48 XC13N060 Data Nominal Tonnage 1.5 2 2.5 3 3.5 4 5 Connections Liquid line o.d.-in. 3/8 3/8 3/8 318 3/8 3/6 3/8 (sweat) Suction line o.d.-in. 3/4 3/4 314 314 7/8 7/8 7/8 'Refrigerant(R-410A)Furnished 3 lbs.13 oz.1 4 lbs.6 oz. 4 lbs.4 oz. 5 lbs.4 oz. 6 lbs.9 oz. 7 Ibs. 12 oz. 9 lbs.0 oz. RFCIV Metering Orifice Size Furnished 0.051 0.057 0.065 0.073 0.076 0.082 0,092 Outdoor Net face area Outer coil 11.33 11.33 13.22 13.22 21.00 18.67 16.33 Coil sq.ft. Inner coil --- --- --- ""- --- --- 15.71 Tube diameter-in, 5/16 5/16 5/16 5/16 5/16 5116 5116 Number of rows 1 1 1 1 1 1 2 Fins per inch 26 26 26 26 26 26 22 Outdoor Diameter-in. 18 18 18 18 22 22 22 Fan Number of blades 3 3 4 4 4 4 4 Motor hp 1/10 1110 1/5 1/5 1/4 1/4 1/4 Cfm 2350 2350 2400 2400 3670 3670 3600 Rpm 1075 1075 1075 1075 825 825 825 Watts 165 165 185 185 295 295 285 Shipping Data-lbs.1 package 150 150 161 164 240 232 249 ELECTRICAL DATA Line voltage data-60 hz- 1 ph 208/230V 208/230V 208/230V 208/230V 2081230V 208/230V 208/230V z Maximum overcurrent protection (amps) 20 25 30 40 45 50 60 Minimum circuit ampacity 12.4 14.7 18.7 24.4 28.1 32.0 34.6 Compressor Rated load amps 9.4 11.2 14.1 18.6 21.2 24.2 26.3 Locked rotor amps 56.6 60.8 64 70 90 100 125 Power factor 0.98 0.98 0.98 0.99 0.99 0.99 0.99 Condenser Full load amps 0.7 0.7 1.1 1 A 1.7 1.7 1.7 Fan Motor Locked rotor amps 1.4 1.4 2.0 2,0 3.2 I 3.2 3.2 OPTIONAL ACCESSORIES -ORDER SEPARATELY Compressor Crankcase Heater 93M04 - 93111 Compressor Hard Start Kit 10J42 _ 88M91 Compressor Low Ambient 45F08 Cut-Off Switch Compressor Sound Cover 27W55 27W56 Compressor Time-Off Control 47J27 Freezestat 3/8 in.tubing 93G35 5/8 in. tubing 50A93 Loss of Charge Switch Kit 8411 Indoor Blower Off Delay Relay 58M81 Low Ambient Kit(Fan Cycling) 34M72 Refrigerant L15-41-20, L15-41-30. Line Sets L15-41-40, L15-41-50 L15-65-30, L15-65-40, L 15-65-50 Field Fabricate NO E-Extremes of operahny range are plus 10446 and minus 5%of line voltage Refrigerant charge sufficient for 15 ft.length of refrigerant lines. HACK type circuit breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. 4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit. XC13-1.5 to 5 Ton Air Conditioner I Page 5 i i� �� i �� ���� RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington,WA 98223 • Phone (360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: !- 1GD - - Project Description: j nt Ciu Prr_ (�►2t�-�_�.—.—__ __--- ___...___. Owner. Address: 1-1410 1 �3�Pt _t��----- �1�''Y -'�- �S - --- - ----- - Phone: 4ZG • sp l • 1? 4 Email: Applicant: Brennan Heating Address: 4601 S 134th PI Seattle 98168 Phone: 206-248-7900 Email: Jaimie@brennanheating.com Applicant Signature: Electronic Signature if submitting on-line 1 hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. CONTRACTOR INFORMATION Contractor Name:Brennan Heating Company: Brennan Heating License Number:BRENNHA971 R9 Expiration: 12/29.1_. Phone:206-248-7900 Email:Jaimie@brennanheating.com STAFF USE ONLY Permit #: Accepted by: Date: ANDL RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 - Phone(360)403-3551 SELECT ALL PROPOSED APPLIANCES ❑ Furnace (80+) ❑ Fireplace Insert ❑ Outdoor BBO ❑ Heat Pump ❑ Freestanding Stove ❑ Hydronic Piping ❑ Type II Hood ❑ Commercial Cooking Appliance ❑ PV System ❑ Boiler ❑ Gas Piping ❑ Storage Tank ]' AC Unit ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: l Pipe Material: Pipe Size: Distance From Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Property Owners Name: Assessor's parcel Site Address: 4�2 Site Plan North Lccend: ----property line ����� Building perimeter X f• Map Scale,1"(m),20'(ft) glie, 4044 rtlOAWX tfv qof Scanned by CamScanner SPECIFICATIONS General Model No. North Region XC13NO18 XC13NO24 XC13NO30 XC13NO36 XC13NO42 XC13NO48 XC13NO60 Data Nominal Tonnage 1.5 2 2.5 3 3.5 4 5 Connections Liquid line o.d.-in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 (sweat) Suction line o.d.-in. 3/4 3/4 3/4 3/4 7/8 7/8 7/8 ' Refrigerant(R-410A)Furnished 3 lbs. 13 oz. 4 lbs.6 oz. 4 lbs.4 oz. 5 lbs.4 oz. 6 lbs.9 oz. 7 lbs. 12 oz. 9 lbs.0 oz. RFCIV Metering Orifice Size Furnished 0.051 0.057 0.065 0.073 0.076 1 0.082 0.092 Outdoor Net face area Outer coil 11.33 11.33 13.22 13.22 21.00 18.67 16.33 Coil sq.ft. Inner coil --- --- --- --- --- --- 15.71 Tube diameter-in. 5/16 5/16 5/16 5/16 5/16 5/16 5/16 Number of rows 1 1 1 1 1 1 2 Fins per inch 26 26 26 26 26 26 22 Outdoor Diameter-in. 18 18 18 18 22 22 22 Fan Number of blades 3 3 4 4 4 4 4 Motor hp 1/10 1/10 1/5 1/5 1/4 1/4 1/4 Cfm 2350 2350 2400 2400 3670 3670 3600 Rpm 1075 1075 1075 1075 825 825 825 Watts 165 165 185 185 295 295 285 Shipping Data-lbs. 1 package 150 150 161 164 240 232 249 ELECTRICAL DATA Line voltage data-60 hz- 1 ph 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V Z Maximum overcurrent protection (amps) 20 25 30 40 45 50 60 3 Minimum circuit ampacity 12.4 14.7 18.7 24.4 28.1 32.0 34.6 Compressor Rated load amps 9.4 11.2 14.1 18.6 21.2 24.2 26.3 Locked rotor amps 56.6 60.8 64 70 90 100 125 Power factor 0.98 0.98 0.98 0.99 0.99 0.99 0.99 Condenser Full load amps 0.7 0.7 1.1 1.1 1.7 1.7 1.7 Fan Motor Locked rotor amps 1.4 1.4 2.0 2.0 3.2 3.2 3.2 OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 93M05 Compressor Hard Start Kit 10J42 88M91 - Compressor Low Ambient 45F08 Cut-Off Switch Compressor Sound Cover 27W55 27W56 Compressor Time-Off Control 47,127 Freezestat 3/8 in.tubing 93G35 5/8 in.tubing 5OA93 Loss of Charge Switch Kit 84M23 Indoor Blower Off Delay Relay 58M81 Low Ambient Kit(Fan Cycling) 34M72 Refrigerant L15-41-20, L15-41-30, Line Sets L15-41-40, L15-41-50 L15-65-30, L15-65-40, L 15-65-50 Field Fabricate NOTE-Extremes of operating range are plus 10%and minus 5%of line voltage. 'Refrigerant charge sufficient for 15 ft.length of refrigerant lines. 'HACR type circuit breaker or fuse. 'Refer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. 'Crankcase Heater and Freezestat are recommended with Low Ambient Kit. XC13-1.5 to 5 Ton Air Conditioner /Page 5 Permit#: 1518 Permit Date: 06/16/17 Permit Type: RESIDENTIAL MECHANICAL Project Name: Bennett Applicant Name: Brennan Heating Applicant Address: 4601 S 134th Place Applicant, City, State, Zip: Seattle,WA 98168 Contact: Jaimie How Phone: 206-248-7900 Email:jaimie@brennanheating.com Scope of Work: Install 18,000 BTU ductless heat pump Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 06/16/2017 Permit Expires: 12/16/2018 Form Permit Type: Status: COMPLETE Assigned To: Launa Black Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00621300006200 17901 33RD AVE NE BENNETT JEAN L 111 Single Family Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# Brennan Heating Jaimie How 206-248-7900 4601 S 134TH PL MECHANICAL COA 602 346 866 CONTRACTOR Brennan Heating Jaimie How 206-248-7900 4601 S 134TH PL MECHANICAL Labor and BRENNHA971R9 CONTRACTOR Industries Fees Fee Description Notes Amount Air Cond.Unit Btu/h<100>; $25.00 Btu/hp>500 Building Permit Table 4-1 $25.00 Processing/Technology $25.00 Total $75.00 Attached Letters Date Letter Description 08/07/2017 Building Permit Revised Permit 06/16/2017 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 06/16/2017 Jaimie How 65172338 cc $75.00 Outstanding Balance $0.00 Notes Date Note Created By: 02/20/2019 Expired.Filed in address files.No final was done. Raelynn Jones 06/16/2017 Lennox MPA018S4S-IP-23.50 SEER-HSPF 10.5;Interior Unit MWMA018S4 Launa Black Uploaded Files Date File Name 08/07/2017 2506927-1518 Revised Issued Permit.pdf 08/07/2017 2506455-Revised-bennettmechappwithspecsandsiteplan.pdf 06/21/2017 2386228-bennettmechapp.pdf 06/16/2017 2375336-1518 Issued Permit.pdf epc Zy !D RESIDENTIAL MECHANICAL 4, PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington,WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES, PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:_____ ` �jnJ� � � I�� _ ,�-1'lr I t_V` �_..._`[_ Project Description: Owner: �1'l'� ---- — --- Address: Phone. '"1� C)I I �j _ Email: Applicant: Brennan Heating — Address: 4601 S 134th P eattle 98168 Phone: 206-248-790 Email: Jaimie@brennanheating.com Applicant Signature Electronic Signature if submitting on-line I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. CONTRACTOR INFORMATION Contractor Name:Brennan Heating Company: Brennan Heating License Number:BRENNHA971 R9 _ _ Expiration:.12/29/ Phone:206-248-7900 Email:Jai mie@brennanheating-com — STAFF USE ONLY Permit #: Accepted by: __ Date: _ _ RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 59th Ave N[ • Arlington, WA 98223 • Phone (360)403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Fireplace Insert Outdoor BBQ Heat Pump Freestanding Stove Hydronic Piping �] Type II Hood Commercial Cooking Appliance PV System Boiler Q Gas Piping Storage Tank AC Unit Solid-Fuel Appliance EJ Other Gas Piping Information Not Applicable: [� Pipe Material: Pipe Size: Distance From Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances 4p, SPECIFICATIONS MPA OUTDOOR UNITS 0.75 - 1.5 TON Nominal Size-Tons 0.75 1 1.5 Outdoor Unit Model No. MPA009S4S MPA012S4S MPA018S4S Ambient Temperature Cooling 5-122 5- 122 5- 122 Operating Range-OF Heating —13-86 —13-86 —13-86 Sound Data Cooling(115V) 51 52 --- (dBA) Cooling (208/230V) 53 54 61 Heating (115V) 54 54 --- Heating(208/230V) 55 57 62 Refrigerant Charge furnished(R-410A) 2 lbs. 12 oz. 2 lbs. 12 oz. 4 lbs.3 oz. Maximum line length with furnished charge-ft. 25 25 25 Additional charge required per ft.-oz. 0.16 0.16 0.16 Compressor No.and Type (1)Rotary (1)Rotary (1)Rotary Refrigerant oil type Ester Oil VG74 Ester Oil VG74 Ester Oil VG74 Refrigerant oil charge-oz. 12.5 12.5 15.2 Low ambient cut-off —13°F —13°F —13°F Connections-in. Liquid/Gas pipe(flare) 1/4/3/8 1/4/1/2 1/4/1/2 Maximum refrigerant pipe length-ft. 98 98 98 Max.difference in level of indoor unit-ft. 40 40 66 Outdoor (No.)Diameter-in. (1)-16.5 (1)- 16.5 (1)-18 Fan Total air volume-cfm(115V) 1180 1180 --- Total air volume-cfm(208/230V) 1120 1180 1470 rpm (115V) 850 850 --- rpm(208/230V) 800 800 800 Outdoor Coil Number of rows 2 2 3 Fins per inch 21 21 18 Fin type Hydrophilic aluminium Tube outside diameter-in. 1/4 1/4 1/4 Tube type Rifled copper tubing Net face area-ft.2 4.72 4.72 5.42 Design Pressure PSIG 550/340 550/340 550/340 Shipping Data Net/Shipping weight(lbs.) 83/88 83/88 111 /120 ELECTRICAL DATA Electrical Characteristics-60 Hz-1 Phase 115V 208/230V 115V 208/230V 208/230V Maximum Overcurrent Protection (amps) 20 15 20 15 20 Minimum circuit ampacity 15 15 15 15 15 Compressor Rated load amps 9 5.3 10 5.7 9.5 Outdoor Fan Rated load amps 0.6 0.42 0.6 0.42 0.5 Motor Output-W 40 40 40 40 50 NOTE-Extremes of operating range are plus and minus 10%of line voltage. HACR type circuit breaker or fuse. Refer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. Single Zone Mini-Split Systems/Page 14 SPECIFICATIONS -WALL-MOUNTED INDOOR UNITS Model No. MWMA009S4 MWMA009S4 MWMA012S4 MWMA012S4 ,_ Nominal Tons 0.75 0.75 1 1 Power Supply-60 hz-1 phase 115V 208/230V 115V 208/230V Rated load amps 0.25 0.06 0.4 0.06 Output(W) 20 20 20 20 Room Temperature Cooling 62-90 62-90 62-90 62-90 Range(°F) Heating 32-86 32-86 32-86 32-86 Air Volume-cfm(High/Medium/Low) 365/265/195 3701270/195 365/265/195 370/275/200 Sound Data (dBA)-Low/Medium/High 24/33/42 26.5/33.4/41.7 24/33/42 28.6/35.8/45.1 Piping Connections-Liquid/Gas-o.d.-flare-in. 1/4/3/8 1/4/3/8 1/4/1/2 1/4/1/2 Drain connection o.d.-in. 1 1 1 1 Net/Shipping weights-lbs. 1 20/26 9n/26 20/26 20/27 SPECIFICATIONS ALL-MOUNTED OOR UNITS o e 018S4 MWMA024S4 MWMA030S4 Nominal Tons 2 2.5 Power Supply-60 hz-1 phase 208/230V 208/230V 208/230V Rated load amps 0.13 0.3 0.5 Output(W) 58 60 60 Room Temperature Cooling 62-90 62-90 62-90 Range(°F) Heating 32-86 32-86 32-86 Air Volume-cfm(High/Medium/Low) 530/410/295 695/625/485 795/645/500 Sound Data (dBA)-Low/Medium/High 30.9/36.3/46.2 35.1/44.5/51.7 37.5/42/49 Piping Connections-Liquid/Gas-o.d.-flare-in. 1/4/1/2 3/8/5/8 3/8/5/8 Drain connection o.d.-in. 1 1 1 Total refrigerant pipe length-ft. 98 98 164 Net/Shipping weights-lbs. 27/35 40/54 40/51 Single Zone Mini-Split Systems/Page 16 Property Owners Name: Assessor's parcel Site Address: Site Plan Rp � North Legend: ----property line Building perimeter Map kale.1"(in)=20'(If) LFNNox MP,g �S-otP I9 AVMP Scanned by CamScanner