21015 State Route 9 NE_BLD1456_2026
CITY OF ARLINGTON �\ ` 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:21015 State Route 9 Permit#: 1456 Parcel#:31051100400500 Valuation:6000.00 OWNER APPLICANT CONTRACTOR Name:COOK INVESTMENTS NW Name: Firepower,Inc. Name:Firepower,Inc. Address: 18818 TELLER AVE STE 277 Address:10220 N Nevada,#130 Address: 10220 N Nevada,#130 City,State Zip:IRVINE,CA 92612 City,State Zip:Spokane,WA 99218 City,State Zip:Spokane,WA 99218 Phone: Phone:509-468-3204 Phone:4254683204 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2015 STORIES: 1 CONST.TYPE: DWELLING UNITS: 0 OCC GROUP: BUILDINGS: I OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return fon and coded City of Arli to 33101. Signature Print Name Date Released By 15ite CONDITIONS Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 5/19/2017 Fire Alarm Fee $176.39 5/19/2017 Fire Review Fee $100.00 5/19/2017 Processing/Technology Fee $25.00 Total Due: $301.39 Total Payment: $100.00 Balance Due: $201.39 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:21015 State Route 9 Permit#• 1456 Parcel#:31051100400500 Valuation:6000.00 OWNER APPLICANT CONTRACTOR Name:COOK INVESTMENTS NW Name:Firepower,Inc. Name:Firepower,Inc. Address: 18818 TELLER AVE STE 277 Address:10220 N Nevada,#130 Address: 10220 N Nevada,#130 City,State Zip:IRVINE,CA 92612 City,State Zip:Spokane,WA 99218 City,State Zip:Spokane,WA 99218 Phone: Phone:509-468-3204 Phone:4254683204 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2015 STORIES: 1 CONST.TYPE: DWELLING UNITS: 0 OCC GROUP: BUILDINGS: I OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI I OARC110. SALFS TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of_Arlit *to 13101. / Jam. .5 ZIC Signature Print Name Date Released By ;ne CONDITIONS Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 5/19/2017 Fire Alarm Fee $176.39 5/19/2017 Fire Review Fee $100.00 5/19/2017 Processing/Technology Fee $25.00 Total Due: $301.39 Total Payment: $100.00 Balance Due: $201.39 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon �I / 1llaw rcc rolf'o Permit Information Date 5/10/2017 Permit Number 1456 Project Name Chinook Lumber Applicant Name Firepower, Inc. Applicant Address 10220 N Nevada,#130 City, State, Zip Spokane,WA 99218 Contact Willie Summers Phone 509-468-3204 Email wsummers@firepowerinc.org Permit Type Fire Alarm Site Address 21015 State Route 9 Valuation 6000.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 1 Proposed Use Assigned To Launa Peterson Property Information Owner Information Parcel#:31051100400500 COOK INVESTMENTS NW COOK INVESTMENTS NW 18818 TELLER AVE STE 277 21015 STATE ROUTE 9 NE IRVINE,CA 92612 Contractors Contractor Name Primary Contact Phone Email Contractor Type License License# Fire ower. Inc. Willie Summers 4254683204 Nsummers fire owerinc.or CONTRACTOR -abor&Industries IREPI"137NO Review Date T e Description Tar et Date I Completed Date Assigned To Status 5/10/2017 =ire Alarm 5/24/2017 <evin Olander In Review Fees Fee Description Notes Amount Fire Review Feel 322.10.00.001 1 $100.00 Totall $100.00 Payments Date Paid By Amount Descri tion Pavment T e Accepted B 5/10/2017 Willie Summers $100.00 34644830 Icc Totall $100.001 Amount Outstanding:$0.00 Uploaded Files I Upload Re Date File Uploaded B 5/10/2017 12:06:54 PM IFire Alarm Permit Awlication CmkdNwHH3GU22E. di Peterson,Launa ''`- FIRE ALARM PERMIT APPLICATION ,�'C IN 1v Department of Community &Economic Development City of Arlington• 18204 59th Ave NE •WA 98223• Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION.INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO,INCLUDE SPECIFICATION SHEETS,WIRING DIAGRAMS, (POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) ✓0 New Fire Alarm Fire Alarm Alteration/Addition Project Address: 21015 SR9 NE Arlington WA 98223 Parcel ID#: Number of Zones/Panels:1 Building Area(Sq Ft). 14.940 Valuation: 6,000 Owner: Cook Investments NW Phone Number: 2067147616 Address: 18818 Teller Ave STE 277 City:Irvine State: CA Zip Code:92612 Contact Person:-Ken Snyder Phone Number: 2067147616 Cell Phone: 2067147616 Email: kennethrsnyder711@gmail.com Address: 21015 SR9 NE City:Arlington State:WA Zip Code: 98223 Contractor: MEKE Properties Phone Number: 2067147616 2590 West Lake Smmmish Redmond WA 98052 Address: City: State: Zip Code: Contractor's License Number:N/A Expiration:N/A Contact Person: Will Summers Email: wsummers@firepowerinc.org Electrical Contractor: Firepower INC Phone Number:5094683204 10220 N Nevada Ste 130 Spokane WA' 99218 Address? City: State: Zip Code: Contractor's License Number:FIREPI*137NO Expiration 08/20/2017 1 hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described property !!ill hp nr,nnr ance with the laws,rules and regulations of the State of Washington �j1lcYlce aSresyc`rr��id ..... ..:- 05/10/2017 Applicants Signature Date Willie Summers Print Applicants Name c-�2 FOR STAFF USE ONLY SAY 1 Vva 0'2011 Permit# Ac cepl Amount Received Receipt# Date Received WEB Form-130 Page 1 of 1 6/16LP i , . i� i ' :� i SIEMENS Catalog Sheet Fire Safety& Security Products `08 Series Notification Appliances ZH & ZR — Strobes, Horns, & Horn / Strobes Application: Indoor (ZR & ZH ZH Series ZR Series Mounting) Product Overview Strobes can be synchronized using the Siemens DSC sync modules, FS-250 panel, XLS panel, or PAD-3 power supply with built-in sync protocol Selectable Continuous Horn or Temporal (Code-3)Tones with 90 or 95 dBA selectable setting (ZH) Ceiling-mount models feature field-selectable Candela settings of 15130175195cd and 1151177cd - Wall-mount models feature field-selectable Candela settings of 15130175/110cd and 135/185cd Base plate is protected by a disposable cover, and the appliances can quickly snap onto the base after the walls are painted Strobes produce 1 flash per second - "Special Applications'listed with Siemens panels EZ Mount Universal Mounting Plate (ZBB) -uses single plate for ceiling and wall mount installations - EZ Mount design -with separate base plate- provides ability to pre-wire the base and test the circuit wiring before the walls are covered &UL Listed &®ULC Listed; FM, CSFM & NYMEA Approved - ADA 1 NFPA compliant Specifications General - AudibleNisual notification appliances shall be listed for indoor use only - Appliances shall be listed under&UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired) and&UL Standard 464 (Fire Protective Signaling) - Appliances shall use a universal back plate,which shall allow mounting to a single-gang, double-gang, 4-inch-square, 4"-octal, or a 3-112"-octal backbox - Two-wire appliance wiring shall be capable of directly connecting to the mounting back plate - Continuity check shall occur for entire NAC circuit prior to attaching any audible I visual-notification appliances - Dust cover shall fit and protect the mounting plate - Dust cover shall be easily removed when the appliance is installed over the back plate - Removal of an appliance shall result in a trouble condition by the Fire Alarm Control Panel (FACP) Received MAY 10 2017 :F,k-b '4S1V `08 Series Notification Appliances 2584 SIEMENS Industry, Inc. Building Technologies Division i�i Specifications — (continued) Strobes — Strobe appliances shall produce a minimum flash rate of 60 flashes per minute (1 flash per second) over the Regulated Input Voltage Range, and shall incorporate a Xenon flashtube enclosed in a rugged Lexan@ lens — Strobes shall be available with two or four field-selectable settings in one unit, and shall be rated—per QUL 1971 —for up to: • 1 513017 511 1 0cd for wall mounted 1351185cd for wall mounted • 15130175195cd for ceiling mounted • 1151177cd for ceiling mounted — Strobes shall operate over an extended temperature range of 32°F to 120°F (0°C to 49°C), and be listed for maximum humidity of 95% RH Strobe inputs shall be polarized for compatibility with standard reverse-polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) Audibles and Audible/Strobe Combinations Horns and horn I strobes shall be listed for Indoor use under&UL Standard 464 Horns shall be able to produce continuous synchronized output or a temporal code-3 synchronized output — Horns shall have at least 2 sound-level settings of 90 and 95 dBA Synchronization Modules — The strobe portion, when synchronization is required, shall be compatible with DSC sync modules, FS-250 panel, XLS panel, or PAD-3 power supply with built-in sync protocol The strobes shall not drift out of synchronization at any time during operation Audibles and strobes shall be able to synchronize on a 2-wire circuit with the capability to silence the audible, if required — Strobes shall revert to a non-synchronized flash-rate, if the sync module or Power Supply should fail to operate (i.e. —contacts remain closed) — All notification appliances shall be listed for Special Applications: • Strobes are designed to flash at 1-flash-per-second minimum over their "Regulated Input Voltage Range" ➢ Note: NFPA-72 specifies a flash rate of 1-to-2 flashes per second, and ADA Guidelines specify a flash rate of 1-to-3 flashes per second ■ All candela ratings represent minimum-effective Strobe intensity, based on&UL Standard 1971 ■ Series ZH Strobe products are listed under®UL Standards 1971 and 464 for indoor use with a temperature range of 32'F to 120°F(0°C to 49°C) and maximum humidity of 93% (± 2%) • Series ZH horns are listed under(&UL Standard 464 for audible signal appliances (Indoor use only) SIEMENS Industry, Inc. Building Technologies Division Mounting Diagram 1.'to 4-bt- 4 0 \1—A (Shown In Inches) Mounting Options SECI 41NC I- instal rrLo-unt--.g pxe as s---,em,n figure 1 to a single-gang, iipc•ian-:Oi:W"o-y nas one nic-rning onematc-.,hla:t—he :!0oble-gang,4"square.-'orlagcn,Dra S'..'Dz7agcri bacthcx top cf:he base,,D i&hexp of tre dt-oicel T-DreiicvedstcDY&.,. 7. if It is des,rcd:o fur-.her secure the devi:--to-'-.,e case,-,hen hv.o .laze and index off cip:ional screws we ,cyide,--c ins a!!tnese is,rews punch c.-. cover. t^e sz,-ivi holes locate.,x.,.he top and bomirr c-,he device C rlm-M iield%ooinng per fig.-s=a-:;3 T:,remove!he:ippliance,push a small f sc----.Ndnver 3. A62'ress wires ba.k to bac-libiax iwo-.he side opening. The scrwjd-,ver rijist clear'.1-is,sra-� 4, �:jac�e dust c,:,v er ove."mounting 1:1-ale to prcsc-can A.he tir-nii ina s release opening by t,,&sengage t,.&snap Ce no:pry off -whle perform-,;wiring con,,Inu;,Y:?-=:v,. housing itoi,.h:he screw driver.Apply c,,-E s sure•wi:n so,-avi:Avm,, Sta�,L_q the stt i� r, inserter in eitcr s,de opening as shown zig -ease the 5 Remove dust cove-bezore snaps-g or in 1.3 C� insc 4 tn re e ants ve ii)Dunvig z 3-,e per fig 3. housing Technical Data ZH and ZH-MG Horn Reverberant d8A Per OUL464 ZH Horn Current Draw [ZH-MC and ZH at 24A In(Amps) Setting0 `iolts � m16-33 '16-OV 24V 33-OV DC High' 0-044 Continuous High 83 87 90 Low' 1 0018 Horn Low 77 81 . 83 FVVR High* 0.075 Code 3 Hom of High 79 82 86 Low* 0045 1 C--ent Claw s the saw for the Coqlanuous March Time' Low 72 76 79 Hem.Cone S ae-d 11`43rcri Tme Settings. *Availa:)Ie in sync mode only SIEMENS Industry, Inc. Building Technologies Division Technical Data - (continued) @k UL Listed Models and Ratings Operating',Iottage Voltage Range Strobe (Special Application) [per-tD IJLC- [Per t% UL1971] ;;526-021 Horn MOuntillg Candela Models* (VDCA,RMS) (VDCNRMS) (0) ZR-MC 16.0-33.0 20.0-31.0 - Wail 15)301761110 ZR-HMC 16.0-33.0 20.0-31.0 -- Wall 1351185 ZR-MC-C 16.0-33.0 20.0-31.0 - Ceiling 15/30175M ZR-HMG-C -16.0-33.0 20.0-310 - Ceiling 1151177 ZH-MC 16.0-33.0 20.0-31.0 X Wall 15)30/75/1-10 ZH-HMC 16.0-33.0 20.0-31.0 X Wall 135,1185 ZH-MC-C 16.0-33.0 20.0-31.0 X Ceiling 15/30175195 ZH-HMC-C 16.0-33.0 20.0-31.0 X Ceiling 115/177 ZH '16.0-33.0 20,0-31.0 1 X I Wall or Ceiling- - - 'Avaiable m red and white (9�UL Current Ratings (ZR Strobe Only) Maximum RMS Current ('AMPS) MC HMC MC-C HMC-C 15cd 30cd 7.5CdlllOCdll 135Cdj 185ed 11 15cd 30cd 75cd 55cd 115cd 177cd DC 16-33VDC DA64 0.0`?8 0.175 1 0.233 11 0.318 0.445 0.069 0.111 0.200 0264 1 0-318 0445 FV%R 46-33VRfU,S 0 10+3 0.164 0.268 0 36,9 0.482 0.684 0 117 D.18010,297 0.398 0.482 0.684 &UL Current Ratings ZH HorniStrobe Maximum RMS Current(AMPS) Horn MC HMC MC-C 1MC-C SeVung 15cd 32cd 1 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 1115cd I 177cd k16DC -33VDC High-- 0.079 0 1 13 0.195 0.259 0371 0 506 0.087 0 131 0.222 0292 0.371 0506 LOW ' 0.070 0.107 0.188 0.246 0.324 DA55 0.075 0 121 0,213 0.277 0.324 0.455High° 0.141 0 200 0.302 0.406 0.521 0,722 0.149 0.216 0.331 0.436 0.521 0.722 33VRNtS taw ' 0.123 0.179 0 290 0.391 0 497 0.699 0.131 0 195 0.319 0.421 0.497 6 699 Current Draw is the Fame for the Continuous Horn: Code 3 Hom and March Time Settings Details for Ordering - (Including Mounting Options & Agency Approvals) Agency Approvals Model Part Description Mounting UL ULC FM CSFM Number Number Options* ZH-R 500-636159 Z Horn: Red B,D,E,F X X X X ZH-W 500-636160 Z Horn: White B,D,E,F X X X X ZH-MC-R 500-636161 Z Horn: Multi Candela(Wall),Red B,D,E,F X X X X ZH-MC-W 500-636162 Z Horn: Multi Candela(Wall),White B,D,E,F X X X X ZH-HMC-R 500-636163 Z Horn: Hi Multi Candela(Wall),Red B,D,E,F X X X X ZH-HMC-W 500-636164 Z Horn: Hi Multi Candela(Wall).White B.D,E,F X X X X ZH-MC-CR 500-636165 Z Horn: Multi Candela(Ceiling),Red B,D,E,F X X X X ZH-MC-CW 500-636166 Z Horn: Multi Candela(Ceiling),White B,D,E,F X X X X ZH-HMC-CR 500-636167 Z Horn: Hi Multi Candela(Ceiling),Red B,D,E,F X X X X ZH-HMC-CW 500-636168 Z Horn: Hi Multi Candela(Ceiling),White B,D,E,F X X X X ZR-MC-R 500-636169 Z Strobe:Multi Candela(Wall),Red B,D,E,F X X X X ZR-MC-W 500-636170 Z Strobe:Multi Candela(Wall),White B,D,E.F X X X X ZR-HMC-R 500-636171 Z Strobe:Hi Multi-Candela(Wall),Red B,D,E,F X X X X ZR-HMC-W 500-636172 Z Strobe:Hi Multi-Candela(Wall),White B,D,E,F X X X X ZR-MC-CR 500-636173 Z Strobe:Multi Candela(Ceiling),Red B,D,E,F X X X X ZR-MC-CW 500-636174 Z Strobe:Multi Candela(Ceiling),White B,D,E,F X X X X ZR-HMC-CR 500-636175 Z Strobe:Hi Multi Candela(Ceiling),Red B,D,E,F X X X X ZRS-HMC-CW 500-636176 Z Strobe:Hi Multi Candela(Ceiling),White B,D,E,F X X X X ZBB-R 500-636193 Accessory-(Includes base,dust cover,mounting screws and installation sheet) ZBB-W 500-636194 Accessory-(Includes base,dust cover,mounting screws and installation sheet) X=listed I approved *=Refer to catalog sheet#:2585 for detailed mounting options Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park,NJ 07932 Brampton,Ontario December 2009 Building Technologies Division Tel:(973)593-2600 (sll) L6T 5E4/Canada Supersedes sheet dated 7/07 FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 Rev.1) URL:www.SBT.Siemens.com1FlB FAX:(905)799-9858 •� I SIEMENS Data Sheet Fire Safety Products Notification Appliances ST — Strobes and Strobe Plates Applications: Indoor / Outdoor -� ST-MC-CW I ST-HMC-CW ST-MC-RETRO- Plate Strobe ST-MC-R Strobe Product Overview — Strobes feature low-current draw — Ceiling-mount, multi-Candela models are available with field-selectable Candela settings of 15130175195cd or 1151177cd — Wall-mount, multi-Candela models are available with field-selectable Candela settings of 15/30175/110cd — Strobes produce one (1) flash per second over the regulated voltage range — Synchronized using the Siemens DSC sync modules; the Siemens 50-point, 252-point and 504-point fire alarm control panels (FACPs), as well as with: • FireFinder@ XLS and MXL@ FACPs • PAD-3 or PAD-4Tm NAC Extenders with built-in sync protocol — Fast installation with In 1 Out screw terminals using 012 to 418 AWG wire — ®UL Listed, ©ULC Listed; FM and CSFM Approved (#7125-0067:0252->Fire Alarm Devices For The Hearing Impaired, non-weatherproof) (*7125-0067:0256->Fire Alarm Devices For The Hearing Impaired,weatherproof) — Meets OSHA 29 Part 1910.165 Specifications — Visual-notification appliances are Siemens Series 'ST' Strobe Appliances or approved equals — The Series 'ST'meet(and are listed for)®UL Standard 1971 for Indoor Fire Protection Service (Emergency Devices for the Hearing-Impaired) — Strobes are listed for indoor use only — Strobe appliances produce a flash rate of one (1)flash per second over the Regulated Voltage Range, and incorporate a Xenon flashtube enclosed in a rugged Lexan@ lens — All inputs are compatible with standard, reverse polarity supervision of circuit wiring by Fire-Alarm Control Panel (FACP) — Strobe Plates, when installed, are the Siemens-Series Strobe Plate (ST-MC-RETRO), and will have the same electronic circuitry as the Siemens Series'ST' — The Series 'ST'Strobe are of low current design — The selector switch for selecting the candela is tamper-resistant `ST' Series Strobes and Strobe Plates 2 5 7 3 SIEMENS Industry,Inc. Building Technologies Division Specifications — (continued) - The strobe intensity for ceiling-mount models has field-selectable settings, and is rated per OUL Standard 1971 for 15130175195cd or 1151177cd where multi-Candela appliances are specified - The strobe intensity for wall-mount models has field-selectable settings, and is rated per ©UL Standard 1971 for 15/30/75/110cd where multi-Candela appliances are specified - When synchronization is required, the appliance is compatible with Siemens' DSC Sync Modules; the Siemens 50-point, 252-point and 504-point fire alarm control panels (FACPs),as well as with: • FireFinder@ XLS and MXL@ FACPs • PAD-3 or PAD-4Tm NAC Extenders with built-in sync protocol - The strobes will not drift out of synchronization at any time during operation - If the sync module or Power Supply fails to operate, (i.e. -contacts remain closed), the strobe will revert to a non-synchronized flash rate - The strobes are designed for indoor(surface of flush) mounting - All notification appliances are backward compatible - The Series'ST'Strobe Appliances incorporates a patented strobe mounting plate that allows mounting to any of the following: • one (1) single-gang or double-gang, 4-inch square (10.2 cm.) back box; • one (1) Model SHBBS surface back box, • one (1) Model SBL2S surface back box (used only with Model ST-MC-RETRO-R) General Notes - Strobes are designed to flash at one (1)flash per second minimum over their"Regulated Voltage Range' - All candela ratings represent minimum effective Strobe intensity based on ®UL 1638 and ©UL Standard 1971 - All notification appliances are listed for"Special Applications' * NFPA-72 specifies a flash rate of 1 to 2 flashes per second, and ADA Guidelines specify a flash rate of 1-to-3 flashes per second Mounting Diagram W2.70* 0424 IS 1O76 I L—iC��- i•—JI �,. i FIRE Q_ FIRE - Shown In Inches Mounting Options B FLUSH MOUNTING D FLUSH OR'1URFACELMNTING r SURFACE MOUNTING�VIEATHERPROOF G(;,43E611-FLU3HLIOUNtkNC,WEATHERPR00F k 8URFACEMOUNTING 57fy SAIL__ MLLOR SURFACE SACv,BOX 2' DEED 4"AG.•x•1.112''-DEEP rr15883 BACKBOx P-M) BAC KBOX •�H"«'1!� 46-,2 x6.0 `� AMP q r11Ttf,) •Ir• A .:,MRSW SCR./75 ONTWI �. 1 f'�• A14P 1� COVER ,� COVER---f I 9ff`R•.9 t---- ..�11 r MAXIlAUMNUMBEROFCONDUCTORB 114A"UMNUMBEROFCONDUOTORA MAXIIAUMNU1ABEROFCONDUCTORS MAXIMUM NUMBEROF CONDUCTOR S MAXIMUM NUTABEROFCONDUGTOR8 AYPG @f8AV1GAfAA1'M R14 AVlG R12 &1'1(i 1fA A10'G 648 A1! NII Y �t� AWGd18 AW' jA Rfd MGM AWGAfBAWfi6i8AWG►f4AW'G612 AV,'GIfIBAV/GIfiBA'WGR44AV,'G81 4 4 4 4 !� 4 4 4 4 4 4 4 4 4 4 b 8 8 8 B SIEMENS Industry, Inc. Building Technologies Division I Technical Data ST-MC Series Strobe: Wall Mount ST-MC-CW&ST-HMC-CW Series: Ceiling Mount Current Ratings(AMPS) Current Ratings(AMPs) MAXIMUM RMS Current MAXIMUM RMS Current Input Voltage 15cd 30cd 75cd 110cd Input Voltage 15cd 30cd 75cd 95cd 115cd 177cd DC 16.0-33.OVDC 0.064 0.098 0.175 0.233 DC 16.0-33.OVDC 0.069 0.111 0.200 0.264 0.318 0.445 FWR 16.0-33.OV RMS 0.108 0.164 0.268 0.368 FWR 16.0-33,OVRMS 0.117 0.180 0.297 0.398 0,4821 0.684 ST-75-WP Strobe:Wall Mount,Weatherproof ST-75-C-WP Strobe: Ceiling Mount,Weatherproof Current Ratings(AMPs) Current Ratings(AMPs) HkamuMRMS Current MAXIMUM RMS Current 115cd 30/180cd 115cd 30/180cd Input Voltage (Per©UL1638) (Per©UL 1971) Input Voltage (Per®UL1638) (Per mUL 1971) DC 16.0-33.OVDC 0.146 0 146 DC 16.0-33.OVDC 0.146 0.146 FWR 16.0-33.OVRMS 0.235 0.235 FWR 1 16.0-33 OVRMS 0.235 0.235 ST-HMC-WPStrobe: Wall Mount,Weatherproof ST-HMC-C-WPStrobe: Ceiling Mt.,Weatherproof Current Ratings(AMPs) Current Ratings(AMPs) MAXIMUM RMS Current MAXIMUM RMS Current 65cd 90cd 135cd 185cd 50cd 75cd 115cd 177cd Input Voltage (Per (Per (Per (Per Input Voltage (Per (Per (Per (Per @UL1638) *OUL1638) ®UL1971) 01.11-1971) ®UL1638 ®UL1638) ®UL1971) BUL1971) DC 16.0-33-OVDC 0.318 0.445 0.318 0.445 DC I 16.0-33.OVDC 0.318 0.445 0.318 0.445 FWR 16.0-33.OVRMS 0.482 0.684 1 0.482 0.684 FWR 116.0-33.OVRMS 0.482 1 0.684 0 482 1 0.684 ST Series Strobes: Weatherproof ©UL 1@ULC Models and Ratings Operating Voltage ©UL Rated Strobe Candela(cd) (Special Application) Voltage Range ®ULC Rated Model Per CANIOULCS526-02 At-40°C, Light Output Per(DUL 1638,®UL1971 VDCNRMS) ®UL1971 and OUL464(VDCNRMS) ( per©UL1638 (�) ST-75-WP* 16.0-33.0 20.0-31.0 115 30/180** 30 ST-75-C-WP* 16.0-33 0 115 30/180** - ST-HMC-C-WP* 16.0-33.0 - 50/75 115/177 - ST-HMC-WP* 16.0-33.0 65/90 1 135/185 - * Available in or white. 180cd is on Axis only- Notes: 1.Strobe will produce 1 flash-per-second over the Input Voltage range. 2.This strobelhorn model meets the required light distribution patterns defined in mUL 1638 1 mUL 1971 1®ULC 5526-02. 3.This model is©UL Listed for indoor use with a temperature range of+320F to+120°F (0°C to+49°C). @UL 1638 is tested from a temperature range of-40OF to+150OF(-40oC to+66°C) with a maximum humidity of 95%RH. The effect of shipping and storage temperatures will not adversely affect the performance of the appliance when it is stored in the original cartons,and is not subjected to either misuse or improper handling of shipment. SIEMENS Industry, Inc. Building Technologies Division L Details for Ordering — (Including Mounting Options & Agency Approvals) Agency Approvals Model Part Description Mounting UL FM CSFM Number Options* ST-MC-CW 500-636098 Strobe: Candela Ceiling,White B,D,E,F,G,J,N,R,X ✓ — ✓ ST-HMC-CW 500-636097 Strobe: Hi Multi-Candela Ceiling, White B,D,E,F,G,J,N,R,X ✓ — ✓ ST-MC-R 500-636099 Strobe: Multi-Candela, Red B,D,E,F,G,J,N,R,X ✓ — ✓ ST-MC-W 500-636100 Strobe: Multi-Candela,White B,D,E,F,G,J,N,R,X ✓ — ✓ ST-MC-RETRO-R 500-636103 Strobe: Multi-Candela Retro Plate, Red D, E,Z ✓ ✓ ✓ ST-75-CR-WP 500-636104 Strobe: Weatherproof Ceiling, Red T,T+WPS-KIT,GG ✓ — ✓ ST-75-CW-WP 500-636105 Strobe: Weatherproof Ceiling, White T,T+WPS-KIT,GG ✓ — ✓ ST-75-R-WP 500-636106 Strobe: Weatherproof Wall, Red T,T+WPS-KIT,GG ✓ ✓ ✓ ST-75-W-WP 500-636107 Strobe: Weatherproof Wall,White T,T+WPS-KIT,GG ✓ ✓ ✓ ST-HMC-CR-WP 500-636177 Strobe: Hi Multi-Candela Ceiling T,T+WPS-KIT,GG ✓ — ✓ Weatherproof, Red ST-HMC-CW-WP 500-636178 Strobe: Hi Multi-Candela Ceiling T,T+WPS-I(IT,GG ✓ — ✓ Weatherproof,White ST-HMC-R-WP 500-636179 Strobe: Hi Multi-Candela Wall T,T+WPS-KIT,GG ✓ — ✓ Weatherproof, Strobe: Hi Multi-Candela Wall ✓ _ ✓ ST HMC W WP 500 636180 T Weatherproof,White ,T+WPS-KIT,GG ST-MC-R-AR1 500-650224 1 Strobe: Agent-Release Only("AGENT"text), Red B,D,E,F,G,J,N,R,X ✓ — ✓ 1: Refer to Sinorix@ Fire Suppression data sheet, 6634,for more information. *:Refer to data sheet 42585 for detailed mounting options Notes: For Model ST- MC( )and ST-CMC(clear)strobe appliances, which are used exclusively for mass notification, refer to data sheet,2588. ✓: Agency Listed I Approved A Siemens WPS-KIT is comprised of one(1)hardware package;two(2)red plugs;two(2)white plugs,and one(1)gasket. Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 1577 North Service Road SIEMENS Industry,Inc. Florham Park,NJ 07932 East Oakville,Ontario March 2016 Building Technologies Division Tel:(973)593-2600 (Sill L6H OH6I Canada Supersedes(Rev.2)dated 12/09 FAX:(908)547-6877 Printed in U.S.A. Tel:[9051 465-8000 URL:www.usa.Siemens.comlFire URL:www.Siemens.CA Y � Intelligent Detection Devices Thermal (Heat) Detector Model H1921 ARCHITECT AND ENGINEER SPECIFICATIONS Provides seven (7) field-selectable settings in the 135' - 174°F (57.2° - 78.9°F) temperature range . Tri-color detector-status light-emitting diode (LED) with 360'viewing . Compatible with Model DPU (device programmer/ loop tester) • Utilizes advanced microprocessor-based signal processing • Provides a low-temperature warning at 40°F (4,4°C) • Each detector is self-testing: • complete diagnostics performed every 10 seconds • Polarity insensitive utilizing SureWire""technology Ldd1ft • Compatible with Model DB-11-series mounting bases Field programmable as rate-of-rise or fixed temperature e Compatible with Siemens Model 'H'-series devices on the same loop (with Model FC9-series fire-alarm control panels) • Superior EMI / RFI immunity @UL521 Listed and ©ULC Listed; • RoHS compliant FM (#3230, 3210), CSFM (#72720067:0258) Approved Product Overview The Intelligent Thermal (Heat) Detector(Model HI921) Additionally, Model HI921 can be configured to provide a provides an advanced method of detection,address low-temperature warning signal at 40'F(4.4°C). This programming and supervision—combined with feature-along with a compatible FACP(FireFinder®XLS, sophisticated FACP communication. Model H1921 uses or with either Model FC922 or Model FC924) -serves as a state-of-the-art thermistor, microprocessor and prevention of water freezing in pipes for sprinkler systems, advanced signal analysis,providing high reliability and meeting NFPA 72. accuracy. Model DPU Further, Model H1921 is a cost-effective,two-wire/ Model H1921 is compatible with the Siemens field-device addressable thermal detector that provides a distinctive, programmer/test unit(Model DPU),which is a compact, advanced feature: field-selectable temperature settings portable,menu-driven accessory for electronically specially tailored for application-specific detection programming and testing detectors easily and reliably. � needs. Model DPU eliminates the need for cumbersome, unreliable Model H1921 provides seven(7)field-selectable mechanical programming methods,such as dials or temperature-range settings: 135°F(57°C)—174°F switches, and reduces installation and service costs by (79°C) with fixed and rate-of-rise programmability. This electronically programming and testing the detector prior to variance provides the customer with maximum installation. flexibility to program the temperature settings to suit multiple application needs and changing environmental Each detector consists of a solid state, non-mechanical conditions. thermal sensor,and microprocessor-based electronics with a low-profile plastic housing. Model H1921 is Underwriters'Laboratories(®UL521)Listed as a thermal (heat)detector. Cerberus(R) PRO e 9901 Received Fire Safety Products Thermal (Heat) Detector MAY ' 0 2011 �klp i L4 sto Answers for infrastructure SIEMENS .a Product Overview — (continued) Each Model HI921 detector base also contains a provision for an A quick,visual inspection is sufficient to indicate the condition of optional,concealed locking mechanism to prevent unauthorized the detector at any time, If more detailed information is removal of the detector head(Model LK 11). required,a printed report can be provided from the Model FC9- For proper operation of Model DPU,the technician selects the series FACPs indicating the status and settings assigned to each accessory's program mode,and enters the desired address. In individual detector. turn,Model DPU automatically sets and verifies the address,as Installation well as tests the detector. When in the'test'mode,Model DPU will perform a series of diagnostic tests without altering the address or All Model HI921 detectors use a surface-mounting base,Model other stored data,allowing technicians to determine if the detector DB-11 or Model DB-11 E,which mounts on a 4-inch octagonal, is operating properly. square or single-gang electrical box. The base utilizes screw- Model DPU operates on AC power or rechargeable batteries, clamp contacts far electrical connections and self-wiping providing flexibility and convenience in programming and testing contacts far increased reliability. equipment from practically any location. The Model DB-11 base can be used with the optional Model LK- 11 detector locking kit,which contains 50 detector locks and an Operation installation tool to prevent unauthorized removal of the detector Model HI921 also utilizes a modern,accurate and shock-resistant head. Model DB-11 has decorative plugs to cover the outer thermistor to sense temperature changes: mounting screw holes. Model H1921 may be installed on the same initiating circuit with the Siemens Model'H'-series detectors[when used with _ 3 1 the Model FC9-series of FACPs]— ' • Model HFP-11 • Model'HMS'-series manual stations • Model'HTRI'-series interfaces • Model HCP output-control devices • Model 'HZM'-series of addressable, conventional zone modules 1 Thermister Application Data Each Model H1921 detector provides seven(7)pre-programmed parameter sets that can be selected by the FACP. Installation of Model HI921 detectors requires atwo-wire circuit. In many retrofit cases, existing wiring maybe used. Detector Supervision and Testing 'T-tapping'is permitted only for Style 4(Class B)wiring. Model H1921,which is listed as a self-testing device,contains a tri- Model HI921 is polarity insensitive,which can greatly color light emitting diode(LED)indicator,capable of flashing any reduce installation and debugging time. one(1)of three(3)distinct colors: Green,Yc,110 r,i,or Red. Model H1921 can be applied within the maximum 50-feet During each flash interval,the microprocessor-based detector center spacing (2,500 sq.ft.areas),per©UL. This monitors the following: application guideline is based on ideal conditions, • Temperatures reaching programmed thresholds specifically,smooth ceiling surfaces, minimal air movement, • Internal sensors and electronics are functional and no physical obstructions between potential fire sources Based on the monitoring results,the LED indicator flashes the and the actual detector. Do not mount detectors inclose following colors based on the following conditions: proximity to ventilation or heating and air conditioning outlets. Exposed joints or beamed ceilings may also affect Flash Flash safe spacing limitations for detectors. Color Condition Interval in seconds Should questions arise regarding detector placement, Normal supervisory operation. observe NFPA 72 guidelines. Good fire-protection system Temperature has not reached 10 engineering and common sense dictate how and when Green* programmed alarm thresholds fire detectors are installed and used. Contact your local or set points. Siemens—Fire Safety distributor or sales office whenever Detector is in trouble and needs 4 you need assistance applying Model H1921 in unusual Yellow: replacement. applications. Be sure to follow NFPA guidelines and®UL Red: III Alarm condition. 1 Listed/®ULC Listed installation instructions—included with every Siemens—Fire Safety detector—and local No Flash: Detector is not powered -- codes as for all fire-protection equipment. *LED can be turned OFF. Please follow the corresponding description of the panel used. S Industry, Inc. Building Technologies Division Cerberus® PRO Specifications Technical Data Model H1921 is plug-in,(2)two-wire thermal(heat)detector, Operating compatible with FireFinder XLS and Model FC9-series FACPs. Temperature +32°F (0°C) to 100°F (38°C) Each Model H1921 detector has microcomputer-chip technology Range: [with 135°F (57°C) alarm- and highly stable,solid-state electronic circuitry. threshold setting] The Model H1921 detector util izes a modern,accurate and shock- Relative Humidity: 0-95%; non-condensing resistant thermistor to sense temperature changes. This electronic-sensing method virtually eliminates thermal lag Air Pressure: No effect associated with mechanical temperature-sensing devices,and provides almost instantaneous temperature status to the FACP. Input Voltage Range: 16VDC-30VDC Model H1921 provides seven(7)field-selectable,pre-programmed AlarmCurrent (max.): 410NA temperature settings: • Fixed 135°F(57°C) Standby Current (max.): 250pA, max. (average) • Fixed 145°F(63°C) • Fixed 155°F(68°C) Maximum Spacing: 50-foot centers (2,500 sq. ft.), per • Fixed 165°F (74°C) NFPA 72 and©ULC-S524 • Fixed 174°F (79°C) • Thermal Rating: Rate-of-Rise; 15°F/min, (8.3°C)at fixed 135°F(57°C) •Rate-of-Rise: 15°F l min.(8.3°C)at fixed 174°F(79°C) Model H1921 provides up to seven(7)field-selectable,pre- programmed temperature settings: Additionally,the Model H1921 detector has the following optional . Fixed 135°F (57°C) feature: . Fixed 145°F (63°C) • Model HI921 provides indication of potential water ■ Fixed 155'F (68°C) freezing for sprinkler systems,via configuration for ■ Fixed 165°F (74°C) reporting a low-temperature warning of 40°F(4,4°C). • Fixed 174°F (79°C) This feature is compatible with FireFinder XLS panels,as . Rate-of-Rise; 15°F/min. (8.3°C/min) well as with Models FC922 and FC924. at fixed 135°F (57°C) ■ Rate-of-Rise: 15°F/min. (8.3°C/min) at fixed 174°F (79°C) Detector Weight: 0.317 lbs. (0.144 kg.) s Industry, Inc. Cerberus® PRO Building Technologies Division Mounting Diagram Details for Ordering DimensionsPart 4 13— (10.5 cm l-� Model NumberDescription HI921 S54320-F5-A2 Thermal (Heat) Detector -- C�—- DB-11 500-094151 Detector Mounting Base DB-1 1 E 500-094151 E Detector Base Ismall} 4-ae^ Remote Alarm Indicator: RL-HC 500-033230 � 4"octagon-box mount, red Remote Alarm Indicator: RL-HW 500 033310 single-gang box mount,red Compatibility Chart LK-11 500-695350 Base Locking Kit Data STI-9604 -- STI Mechanical Protection Guard Model Sheet Description See: Www.STI-USA.com for further details on ordering Number Number Model STI-9604. — 6300 FireFinder®XLS(system overview) FC901 9813 50-point panel In Canada, order: FC922 9815 252-point system(networkable) Part FC924 1 9815 1 504-point system(networkable) Model Number Description DB-11C 500-095687 Detector Mounting Base (®ULC Listed) S Cerberus@ PRO NOTICE—The information contained in this data-sheet document is intended only as a summary, and is subject to change without notice. The devices described here have specific instruction sheets that cover various technical, limitation and liability information. Siemens Industry, Inc.—Building Technologies Div. Copies of these instruction sheets and the General Product Warning and Limitations document, 8 Fernwood Road • Florham Park, N1 07932 which also contains important information,are provided with the product and,are available Tel: (973) 593-2600 • Fax: (908) 547-6877 from the Manufacturer. Information contained in these documents should be consulted before specifying or using the Web: www.USA.Siemens.com/Cerberus-PRO product. For further information or assistance concerning particular problems contact the Manufacturer, Building Technologies Apri12014—Supersedes sheet dated 6/2013 9 9 (Rev.3) SII—Fire Safety [Printed in U.S.A I SIEMENS Data Sheet Fire Safety&Security Products HMS-Series Intelligent Initiating Devices Models HMS-D, HMS-S ARCHITECT AND ENGINEER SPECIFICATIONS • Durable design • Shock-and-vibration resistant • Pull-down lever is down,until manually reset ■ Reset with Allen Key • No break rods necessary • Custom microcomputer-chip technology • Dynamic supervision to the fire-alarm control panel(FACP) _ a a • Polarity insensitive via SureWireTM technology • Two-wire operation • Surface or semi-flush installation • Model DPU programs and verifies address and tests functionality of each device ■ Electronic-address programming is easier, more efficient and more dependable • Comes in single-action(Model HMS-S)and double-action(Model HMS-D)stations Model HMS-D Model HMS-S • ®UL Listed and @ULC Listed; Dual-Action Station Single-Action Station FM,CSFM& NYC Fire Dept.Approved Product Overview Models HMS-S and HMS-D intelligent manual fire- memory—identification information as well as alarm boxes provide the most advanced method of important operating-status data. address programming and supervision. Each Model Innovative technology from Siemens—Fire Safety HMS-series manual fire-alarm box achieves the state also allows all Model HMS-series intelligent manual of an'intelligent-initiating device'by incorporating fire-alarm boxes to be programmed via the Device custom microcomputer-chip technology with Programmer I Test Unit(Model DPU). Model DPU is a sophisticated, bi-directional communication compact, portable and menu-driven accessory that capabilities with the FACP. makes programming and testing of a manual fire- Specifications alarm box device faster, easier and more dependable Models HMS-S and HMS-D are constructed of than previous methods. durable, molded polycarbonate material that is matte The programmer I tester eliminates the need for finished in with raised white lettering. The mechanical-addressing mechanisms of a device housing accommodates a'pull-down'lever, which— because Model DPU electronically sets the address when operated—locks into position; indicating the of the manual fire-alarm box into its microcomputer manual fire-alarm box has been activated. chip, non-volatile memory. Hence, vibration, The pull down lever remains down I in the'locked' corrosion and other conditions that can compromise position, until the fire-alarm box is manually reset. or even deteriorate mechanical-addressing The manual fire alarm box can only be reset by mechanisms are�����rr a�cuse for concern. opening the hinged housing cover with an Allen key; followed by closing and locking the cover. °i"" Models HMS-S and HMS-D operate with Siemens— Lb 14 Fire Safety FACPs. The microcomputer chip to the manual fire-alarm box has the capacity of storing—in HMS Series Intelligent Initiating Devices 6306 SIEMENS Industry, Inc. Building Technologies Division � l III 1 Specifications — (continued) Details for Ordering Models HMS-S and HMS-D are fitted with screw Model Part shipping weight terminals for connection to an addressable circuit, Number Number Description Lbs. kg. and can be either surface or semi-flush mounted. ISMS-S 500-033200 Addressable Manual Fire 2.0 .90 The Model HMS-series manual fire-alarm boxes Alarm Box Single Action derive their power, communicate information and HMS-0 500-033400 Addressable Manual Fire 2.5 1.13 Alarm Box,Double Action receive commands over a single pair of wires. SB-SR 310-019860 Surface Mounting Box 1.5 0.68 The Model HMS-series is compatible on the same LTP 500-620490 ResetTooi Package 0.5 0.23 circuit with all W-series detectors, interfaces or (Contains 2 tools] addressable, conventional zone modules. Electrical Ratings Current Draw(Active or Standby)— 1.5mA Mounting Diagram SURFACE—MOUNTING ENCLOSURE 4?,,- SING �/� 4 In �HOUSING NAMEPLATE HINGED TO SB-5R BACKPLATE 1-Y16 In. I 0 o 5-1/2 in, A I I R HOUSiN� �,• 0 LOCKING o 3 in. SCREW BACKPLATE � � a 0 i 3-1/2 in DEEP 1., SWITCH BOX (USER SUPPLIED) Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park,NJ 07932 Brampton,Ontario December 2017 Building Technologies Division Tel:(973)593-2600 (Slp L6T 5E4/Canada Supersedes sheet dated 6/10 FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 (Rev.z( URL:www SBT Siemens.com/FIS FAX:(905)799-9858 -r Cerberus PRO Fire Safety 50-Point Addressable Fire Alarm Control Panel Model FC901 ARCHITECT AND ENGINEER SPECIFICATIONS • An addressable fire alarm control panel(FACP) comprised of the following three(3)system components: e ■ Main board(Model FCM901-1.13) • 170-Watt power supply(Model FP2011-U1) ■ System enclosure(Model FH901-U3/113) I ) ) ) • System features: 1 ) ' ■ Supports 50 addressable devices on one(1)'Class A', or one(1)—two(2)'Class B'circuits ■ Includes one(1)'Class A',or two(2)'Class B' notification appliance circuits(NACs) • Built-in digital alarm communication transmitter(DACT) • Built-in RS-485 connection for remote annunciators• Resettable and non-resettable 24VDC auxiliary power • Alphanumeric keypaftd1j • Optional connectivity to a leased-line/city-tie for manual configuration module • ®UL 864 9th Edition Listed' ■ Off-normal warning message prior to reset • Fast and easy set-up with custom-configuration tool CSFM & NYC Fire Department Approved Product Overview Main Board Model FC901 is an addressable FACP that The Model FCM901-U3 main board provides system provides a cost-effective solution for simple fire- display and control, as well as connections for alarm system applications. system field wiring,via removable terminal blocks. Small and compact in design, Model FC901 is The 3.5-inch (8.9 centimeters) by 1.5"(3.8 ideal for small fire-protection applications using centimeters) liquid-crystal display (LCD) screen less than 50 addressable devices: shows all system messages and event status. Each ■ retail outlets I strip malls • doctors'offices event may have a custom message up to 28 • dry cleaner shops . restaurants,etc. characters that describes the events location. With its built-in DACT and two(2) NACs, Model The backlit LCD screen illuminates on any system FC901 is powerful enough to economically event, or manual key press. New,'unacknowledged' meet the needs of these applications. Further, events are indicated by a flashing exclamation point the 50-point FACP is CSFM (Listing No.: 7165- (T). Once'acknowledged,'the exclamation point 0067:0259) and FDNY(Certificate of Approval: changes to a check mark(V'). A system-status line #6104) Approved. shows the quantity of events presently active. Specifications The main board system-statti9jig' t The Model FC901 FACP consists of a main board emitting diodesffdel �� swaYlo UNWON (Model FCM901-U3);a 170-Watt power supply conditions of MNOI:DING DEPARTMENT (Model FP2011-U1),and a Model FH901-U3 1 • Power Alarm APPROVED system enclosure. The programming • ■ Trouble software for Model FC901 is held in flash Supervisory DATE By d electrically erasable programmable read-only • Ground Foul memory (EEPROM). NO CHANGES TM Received UNLESS APPu Y H Cerberus PRO BUILDING IN T l Fire Safety&Security Products MAY ® 2111-77 FAGP f �i� to J(( I"/` A,ismm�s OFFICE PYSIEMENS r �i'-1MT1A4�#aQ�11�4�",,IiIJB Q3VOnggA �a JP • Y, IT. A ktliwj "i Tr . � ' . Specifications — (continued) There are also LEDs to indicate when audible circuits Model FC901 can be configured using the are'active'or'silenced.' The main board supports four configuration tool or manually from the (4) system-control buttons, including: Acknowledge; alphanumeric keypad on the main board. An auto- Alarm Silence; Unsilence, and Reset. configuration feature creates a basic system The system offers an off-normal warning feature, configuration of all connected devices to accelerate alerting users when active devices are not ready for initial system commissioning. reset. These active devices may include manual stations that have not been reset; smoke detectors with 170-Watt Power Supply smoke remaining in the optical chamber, etc. The Model FCM901-U3 main board also supports Additionally, the main board supports an alphanumeric connection to the system power supply. The 170- keypad, as well as navigation keys,which are used for Watt power supply (Model FP2011-U1) incorporates scrolling maintenance functions and system a 4.OA, non-resettable slow-blow fuse on the configuration. primary input, and includes a built-in AC-line filter for surge and noise suppression. Model FP2011-U1 The main board supports connection for up to 50 mounts in a standard Siemens—Fire Safety addressable devices,via one (1)'Class A',or one(1)to enclosure, and there are no serviceable Siemens— two (2)'Class B'circuits. The loop supports all C-NET Fire Safety parts to be maintained. devices, including the Cerberus PRO Fire Safety and Model'H'-series devices. The main board also supports one (1)'Class A'or two (2)'Class B'NACs. 50-Point Addressable System Enclosure Each NAC supports a maximum 2.5 Amps—with 2.5 The Model FH901-U3 I R3 enclosure for the 50-point Amps, max. allowed between the NACs. Each NAC addressable fire system, Model FC901, supports all can be set to a synchronized strobe, for horn-strobe system modules. The enclosure also supports 12AH devices, or for audible devices. Audible devices can batteries. be set for: Note: For systems requiring larger than 12AH batteries, • STEADY' use a OUL Listed battery box. • 'ANSI Temporal 3' The Model FH901-U3 I R3 enclosure for the 50-point • 'March Time 30 160 1 120 Codes' panel is comprised of a dual-mounting setup that The main board supports four (4)'Form C'relays for allows the main board to be partially mounted in a Alarm, Trouble, Supervisory and user-programmable lower-to-upper position. When temporarily installed events. Each relay is rated at 2 Amps at 30VDC in the lower position, technicians are allowed more maximum, resistive. The main board supports two space to install field wiring at the time of system set- (2) auxiliary 24VDC connections. Upon system reset, up. When field-wiring installation is complete, the one (1) connection interrupts the power for five main board shall be moved to the upper position for seconds for use with (4) four-wire conventional standard mounting prior to applying power to the detectors. Each auxiliary-power output is 24VDC, system. nominal—rated at 0.75 Amps. Additionally, the enclosure supports an optional The main board contains a built-in DACT(Model battery bracket(Model FHA901-U1) that can be used FCA2015-A1), which provides communication between to secure batteries up to 12AH. Model FHA901-U1 is Model FC901 and with the central or remote required to comply with seismic certification, monitoring station. The built-in DACT supports two (2) pursuant to ASC I SEI 7-05, Section 13.2.2. separate programmable accounts,as well as two (2) A flush-mount trim kit(Model FHA902-Ul I R1) is connections to the public-switched telephone network. also available for use when flush mounting Model The connections support RJ31X male connectors. FH901-U3 I R3. The main board contains a battery-charging circuit, Optional Accessories providing connection to lead-acid batteries rated at The Model FC901 FACP has the capability of 24VDC, nominal. The main board can charge up to operating an optional leased-line, city-tie module 18 AH batteries. (Model FC12020-U1) that provides a local-energy The main board contains a universal serial bus (USB) output for municipal call-box connection. The connector that supports connection for system leased-line, city-tie module is installed on the back of configuration and module firmware upload, via the the main board of the Model FC901 FACP, and all custom-configuration tool. field wiring is connected to the main board. SIEMENS Industry, Inc. CerberusTM PRO Building Technologies Division Specifications— (continued) Temperature and Humidity Range Model FC901 contains a built-in RS-485 connection Model FC901 is 1UL 864 91h Edition Listed for on the main board, thus eliminating the need for an indoor dry locations within a temperature range of additional communication module. The fire-system 120+I-3°F (49+I-2°C) to 32+1-3°F(0+I-2°C) and a displays (FSD901-U3 I R3) are remote LED I LCD units relative humidity of 93+1-2%at a temperature of that show the existing status of the Model FC901 FACP. 90+I-3°F (32+I-2°C). The Model FSD901-U3 1 R3 optional display supports the following LEDs for system-status conditions: Related Documentation • Power Product Data Sheet Number • Alarm 170-Watt power supply 9806 • Trouble • Supervisory Leased Line 1 city tie module 9810 Ground-Fault There are also LEDs to indicate when audible circuits Details for Ordering are'active'or'silenced.' The main board supports four Model Pa rt (4) system-control buttons, including: Acknowledge; Number Number Description Alarm Silence; Unsilence, and Reset. FCM901-U3 554433-B101-A1 Cerberus PRO Main Board For Model FSD901-U3 1 R3, a LED will illuminate for any (for 50-point FACP} given Alarm, Supervisory and Trouble Cerberus PRO- FP2011-U1 S54400-Z59-A1 170-Watt Power Supply system event. A 3.5-inch (8.9 centimeters) by 1.5" FH901-U3 S54433-B103-A3 System Enclosure,Black (3.8 centimeters) LCD screen will give details of the {for 50-point FACP} event in alphanumeric form. The display screen can be FH901-R3 S54433-Bl03-A4 System Enclosure,Red scrolled to reveal additional events. Optional remote- {for 50-point FACP} system-control capabilities are also available. Optional Accessories The dimensions (based upon connection to a one Model Pa rt - height-unit enclosure) for Model FC901 are as follows: Number Number Description Approximate size: 16.25"(41.3 cm.) [H]; FHA901-Ul S54433-B107-A1 Battery Bracket 18"(46 cm.) [W]; FHA902-Ul S54433-B106-A1 Flush-Mount Trim Kit,Black 5"(41.3 cm.) [D] FHA902-Rl S54433-B106-A2 Flush-Mount Trim Kit,Red The weight(without operating unit or batteries) is FCI2020-Ul S54400-A57-A1 Leased-Line I City-Tie Module approximately 9 Lbs [4082 g]. FSD901-U3 S54433-C102-A1 System Display,Black {for 50-pointsystem} FSD901-R3 S54433-Cl02-A2 System Display,Red {for 50-point system} SIEMENS Industry, Inc. CerberusTM PRO Buildina Technoloaies Division SIEMENS CerberusT^^ PRO NOTICE—The information contained in this data-sheet document is intended only as a summary,and s subject to change without notice. The devices described here have specific instruction sheets that cover various technical,limitation and liability information. Siemens Industry, Inc.—Building Technologies Div. Copies of these instruction sheets and the General Product Warning and Limitations document, 8 Fernwood Road • Florham Park, NJ 07932 which also contains important information,are provided with the product and,are available from Tel:(973) 593-2600 • Fax:(908) 547-6877 the Manufacturer. Information contained in these documents should be consulted before specifying or using the Web: www.USA.Siemens.com/Cerberus-PRO product. Forfurther information or assistance concerning particular problems contactthe Manufacturer. Building Technologies Division April 2012—supersedes sheet dated R Vo11 SIl—Fire Safety [Printed In U.S.A j Intelligent Detection Devices Multi-Criteria Fire Detector Model OH921 ARCHITECT AND ENGINEER SPECIFICATIONS • Multi-criteria addressable fire detector that incorporates photoelectric and thermal sensors • Compatible with device programmer/ loop tester, Model DPU • Responds to both flaming and smoldering-fire signatures • Polarity insensitive utilizing SureWire'technology • Tri-color detector status LED with 3600 viewing • Remote sensitivity-measurement capability • Field-selectable application profiles • Each detector is self-testing: • complete diagnostics performed every 10 seconds • self monitored for sensitivity within SUL Listed limits 0000 • Superior EMI immunity • Compatible with DB-11 series mounting bases • Compatible with FireFinder@ XLS (with Siemens Model W-series devices on same loop) • Listed and approved as heat detector • Rate-of-Rise Detection: 15°F I min. (8.3°C I min), •Automatic environment compensation and fixed 135°F (57°C) •OUL Listed and ©ULC Listed; • RoHS compliant FM (#3230,3210), CSFM (#7272-0067:0258)Approved Product Overview The Model OH921 photoelectric detector Additionally, Model OH921 is a plug-in, addressable, incorporates both optical and thermal sensors, and two-wire and multi-criteria detector(with both uses signals in a neural network to create an photoelectric and thermal inputs)that is compatible intelligent multi-criteria detector. The with FireFinde&XLS systems. encompassing result is a detector that provides Model OH921 is compatible with the Siemens—Fire enhanced detection to a wide range of products of Safety field-device programmer/test unit. Model combustion. DPU is a compact, portable, menu-driven accessory Model OH921 utilizes advanced multi-criteria for electronically programming and testing detectors, detection technology. The multi-criteria detector easily and reliably. also has state-of-the-art microprocessor circuitry Model DPU eliminates the need for cumbersome, (with error check), as well as detector self- unreliable mechanical programming methods, such diagnostics and supervision programs that is used as dials or switches, and reduces installation and on Cerberus PRO 50-point(Model FC901), 252- service costs by electronically programming and point(Model FC922/ FV922)and 504-point(Model testing the detector prior to installation. FC924 I FV924)addressable fire alarm control panels(FACPs). Received 9900 Cerberus® PRO 11 0 2,017 Fire Safety Products Multi-Criteria Fire Detector Answers for infrastructure SIEMENS .. r_ Product Overview — (continued) Profile Overview Each detector consists of a dust-resistant photoelectric Model OH921 provides two(2)different alarm sources that chamber,a solid state,non-mechanical thermal sensor,and can be selected individually(ON or OFF)by the control panel. microprocessor-based electronics with a low-profile plastic Alarm Source 1 (Neural Network)-Combines smoke-heat housing. Every Model OH921 fire detector is shipped with a with the following selectable profiles: protective dust cover: • Sensitive - - • Robust • Standard Sensitive: This parameter set is practically suitable for areas where few misleading sources of false alarm are present,and 1) Model OH921 _ — - 2) Dust cover is appropriate where priority is given to detecting open fires detector (provided with 2 each detector) as soon as possible(e.g.-typically a clean application with controlled environmental conditions.) Robust: This parameter set offers improved resistance to Operation false alarms in areas where misleading sources,such as cigarette smoke or exhaust fumes,may cause a nuisance Model OH921 utilizes an infrared light emitting diode(IRLED), alarm. and infrared light-sensing photodiode. Under normal Standard: This parameter set is practically apt for normal conditions,light transmitted by the LED is directed away from office,hotel lobby type applications and is the default setting. the photodiode and scattered through the smoke chamber in a controlled pattern. Alarm Source 2 hermistor)-Heat only,provides the The smoke chamber is designed to manage light dissipation following: and extraneous reflections from dust particles or other non- • Static I fixed at 135°F (57°C), default setting smoke,airborne contaminants in such a way as to maintain - Rate-of-Rise Detection: 15°F I min. (8.3'C I min) stable,consistent detector operation. When smoke enters the If the detector is not programmed,Model OH921 will default detector chamber,light emitted from the IRLED is scattered by to a'standard'profile setting,which allows operation for a the smoke particles,and is received by the photodiode. normal office-type environment Model OH921 also utilizes a modern,accurate and shock Model OH921 contains a tri-color LED indicator,capable of resistant thermistor to sense temperature changes. flashing any one(1)of three(3)distinct colors: The signal processing with detection algorithms allows the ,or . During each flash interval,the detector to first gather smoke and thermal data,and then microprocessor-based detector monitors the following: analyze this information in the detector's'neural network.' By : Smoke in its sensing chamber com aiin data received with the common characteristics of Smoke sensitivity is within the range indicated p g on the nameplate label fires or fire signatures,Model OH921 can compare these • Internal sensors and electronics signals to those of deceptive phenomena that cause other detectors to false alarm. Based on the results of the monitoring,the LED indicator flashes the following: Flash Flash ,s Color Condition Interval (in seconds) o�:�. 1 Normal supervisory �rj i Green': operation. Smoke sensitivity 10 is within rated limits. 1) Labyrinth 4) Heat sensor Yellow: Detector is in trouble and 4 2) Optical transmitter needs replacement. 3) optical receiver Red: Alarm condition. 1 Each Model OH921 detector provides three(3)pre- No Flash: Detector is not powered. — programmed parameter sets that can be selected by the FACP. " LED can be turned OFF. Please follow the corresponding description of the panel used. SIEMENS Industry,Inc. Cerberus@) PRO Building Technologies Division 1 Installation All Model OH921 detectors use a surface-mounting base, Model OH921 fire detectors can be applied within the Model DB-1 1 or Model DB-11 E, which mounts on a 4- maximum 30-feet center spacing (900 sq.ft.areas,) inch octagonal, square or single-gang electrical box. as referenced in NFPA 72. This application guideline is The base utilizes screw-clamp contacts for electrical based on ideal conditions,specifically, smooth ceiling connections and self-wiping contacts for increased surfaces,minimal air movement,and no physical reliability. obstructions between potential fire sources and the The Model DB-11 base can be used with the optional actual detector. Do not mount detectors in close Model LK 11 detector locking kit, which contains 50 proximity to ventilation or heating and air detector locks and an installation tool to prevent conditioning outlets. Exposed joints or beamed unauthorized removal of the detector head. Model DB- ceilings may also affect safe spacing limitations for 11 has decorative plugs to cover the outer mounting detectors. screw holes. Should questions arise regarding detector placement, Model OH921 may be installed on the same initiating observe NFPA 72 guidelines. Good fire-protection circuit with the Siemens Model 'H'-series detectors system engineering and common sense dictate how (Models HFP-11 and HFPT-11); Model 'HMS'-series and when fire detectors are installed and used. Contact manual stations; Model 'HTRI'-series interfaces; Model your local Siemens Industry-Fire Safety distributor or HCP output-control devices, or Model 'HZM'-series of sales office whenever you need assistance applying addressable, conventional zone modules for Model OH921 in unusual applications. Be sure to FireFinder XLS control panels. follow NFPA guidelines and&UL Listed 1®ULC Listed All Model OH921 detectors are approved for operation installation instructions-included with every Siemens within the®UL-specified temperature range of 32 to -Fire Safety detector-and local codes as for all fire 100°F(0 to 380C). protection equipment. Model DPU Technical Data The Device Program I Test Unit accessory is used to Operating program and verify the address of the detector. The Temperatures: +32°F (0°C) to 100°F (38°C) technician selects the accessory's program mode, and enters the desired address. Model DPU automatically Relative Humidity: 0 - 95%; non-condensing sets and verifies the address and tests the detector. Air Velocity: 0 -4,000 ft. I min (0-20m I sec) Model DPU operates on AC power or rechargeable batteries, providing flexibility and convenience in Air Pressure: No effect programming and testing equipment from practically any location. Maximum 30-foot centers (900 sq. ft.), Spacing: per NFPA 72 and©ULC-5524 Listed When in the test mode, Model DPU will perform a series of diagnostic tests without altering the address Input Voltage Range: 16VDC- 30VDC or other stored data, allowing technicians to determine if the detector is operating properly. Alarm Current: 280µA, max. Application Data Standby Current: 280µA, max. Installation of the Model OH921 series of fire detectors (average) requires a two-wire circuit. In many retrofit cases,existing Thermal Rating: wiring may be used. 'T-tapping'is permitted only for'Style • Fixed-temperature set point: 135°F (57°C) 4'(Class B)wiring. Model OH921 is polarity insensitive, • Rate-of-Rise Detection: 15°F I min. (8.3°C I min) which can greatly reduce installation and debugging time. Detector Weight: 0.317 lbs. (0.144 kg.) Mechanical Protection Guard: OUL Listed 1®ULC Listed with STI Guard Model STI-9604 SIEMENS Industry,Inc. CerberusOl PRO Building Technologies Division Mounting Diagram Details for Ordering Dimensions Model Part Description 4.13" I10.5 Number OH921 S54320-F6-A2 Addressable Multi-Criteria Fire Detector 1 D DB-11 500-094151 Detector Mounting Base for Series 11 DB-11 E 500-094151 E Detector Base{small} RL-HC 500-033230 Remote Alarm Indicator: ' -"", 4"octagon-box mount, red RL-HW 500-033310 Remote Alarm Indicator: single-gang box mount, red LK-1 1 500-695350 Base Locking Kit for Series 11 Detectors Compatible FACPs Data STI-9604 — STI Mechanical Protection Guard Model Sheet Description See: www.STl-USA.coni for further details on ordering Number Model STI-9604. 6300 FireFinder XLS FC901 1 9813 50 oint FACP In Canada, order: FC922 9815 252 oint addressable FACP Part 252-point intelligent voice Model Number Description FV922 9821 communication panel DB-1 1 C 500-095687 Detector Mounting Base FC924 9815 504 oint addressable FACP for Series 11 Detectors(®ULC Listed) FV924 9821 504-point intelligent voice communication panel SIEMENS Ce rbe rus® PRO NOTICE—The information contained in this data-sheet document is intended only as a summary, and is subject to change without notice. The devices described here have specific instruction sheets that cover various technical, limitation and liability information. Siemens Industry,Inc.— Building Technologies Div. Copies of these instruction sheets and the General Product Warning and Limitations document, 8 Fernwood Road • Florham Park, NJ 07932 which also contains important information,are provided with the product and,are available Tel: (973) 593-2600 • Fax: (908) 547-6877 from the Manufacturer. Information contained in these documents should be consulted before specifying or using the Web: www.USA.Siemens.com/Cerberus-PRO product. For further information or assistance concerning particular problems contact the Manufacturer. Building Technologies iesDivision March2015—Supersedessheetdated10/2014 (Rev.7) Sll —Fire Safety [Printed in U.S.A I FIRE ALARM ` PERMIT APPLICATION �iI1 CK�O Department of Community & Economic Development City of Arlington • 18204 59th Ave NE •WA 98223 • Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO, INCLUDE SPECIFICATION SHEETS,WIRING DIAGRAMS, (POINT TO POINT WIRING), AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) ✓❑ New Fire Alarm ❑ Fire Alarm Alteration/Addition Project Address: 21015 SR9 NE Arlington WA 98223 Parcel ID#: Number of Zones Palle s:1 B i d ng Area i,Sq I t1: 14.940 Valuation: 6,000 Owner: Cook Investments NW Phone Number: 2067147616 Address: 18818 Teller Ave STE 277 City:Irvine State: CA Z p Code: 92612 Contact Person:Ken Snyder Phone Number: 2067147616 Cell Phone: 2067147616 Email: kennethrsnyder711@gmail.com Address: 21015 SR9 NE City:Arlington State:WA Z p Code: 98223 Contractor: MEKE Properties Phone N ember: 2067147616 Address: 2590 West Lake Smmmish C ty: Redmond State: WA Z p Code:98052 Contractor's License Number: N/A Expiration:N/A Contact Person: Will Summers Email: wsummers@firepowerinc.org Electrical Contractor: Firepower INC Phone Number:5094683204 10220 N Nevada Ste 130 Spokane WA' 99218 Address; C ty: State: Zip Code: Contractor's License Number:FIREPI*137NO Expiration:08/20/2017 hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described r will hPaarp nrri �n—c with the laws,rules and regulations of the State of Washington. ° e 05/10/2017 Applicants Signature Date Willie Summers Print Applicants Name FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received WEB Form—130 Page 1 of 1 6/16LP Permit#: 1456 Permit Date: 05/10/17 Permit Type: FIRE ALARM Project Name: Chinook Lumber Applicant Name: Firepower, Inc. Applicant Address: 10220 N Nevada, #130 Applicant, City, State, Zip: Spokane,WA 99218 Contact: Willie Summers Phone: 509-468-3204 Email: wsummers@Erepowerinc.org Scope of Work: Valuation: 6000.00 Square Feet: 0 Number of Stories: 1 Construction Type: Occupancy Group: ID Code: Permit Issued: 05/22/2017 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Launa Black Property Parcel# Address Legal Description Owner Name Owner Phone Zoning COOK 521 Lumber&Other 31051100400500 21015 STATE ROUTE 9 NE INVESTMENTS Building Materials NW Contractors Contractor Primary Contact Phone Address Contractor Type License License# Firepower,Inc. Willie Summers 4254683204 10220 N Nevada, CONSTRUCTION Labor&Industries FIREPI*137NO #130 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 06/09/2017 FA00.FIRE ALARM Smoke,Heat&visuals in 06/09/2017 BUILDING Completed FINAL place&tested.Central Station verification complete Plan Reviews Date Review Type Description Assigned To Review Status 05/10/2017 FIRE ALARM BUILDING Fees Fee Description Notes Amount Fire System Plan Review Table 4-1 $100.00 Processing/Technology $25.00 Fire Alarm Plan Review Fee $176.39 Total $301.39 Attached Letters Date Letter Description 05/19/2017 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 05/10/2017 Willie Summers 64644830 cc $100.00 05/19/2017 Bartley Onoday 64794414 cc $201.39 Outstanding Balance $0.00 Uploaded Files Date File Name 05/22/2017 2302640-1456 Issued Permit.pdf 05/10/2017 2276610-Fire Alarm Permit Application CmkdNwHH3GUo2E.pdf A %�IEAT DETECTOR ABOV HEAT DETECTOR \\ ,,// T-BAR CEILINJ T-BAR CEILING 4 IN BUSINESS FOR .::.: .�._...,- LIFE SAFETY! CHECKCU 10220 N.NEVADA ST.STE.#130 SPOKANE, WA 99218 PHONE: (509)468-3204 2B -- FAX: (509)468-2758 ENTRY E©� ) ENGINEERING SOLUTIONS FOR: FIRE ALARM"NURSE CALL 'fro"' ' ® B 28 B Fc d PHONE SYSTEMS*SECURITY' e % ° 8-". B CCTV*SOUND SYSTEMS" Arlington Health O ACCESS CONTROL B RW and Rehabilitation HEALTH CARE COMMUNICATIONS ' PERMIT GOF1Y CTR OFFICE o B i mlN.ehington9 SET tDFFIGE OF=:CE - I �0c HEAT DETECTOR ABOV 121] 120 5 5 S_ HEAT DETECTOR T BAR ABLOVEG IP.5 N T-BAR CEILING 00 _ 0 - w \ OFFICE -RACKS UNDER W-O'HIGH- IO-F'FICE W II9 -INSTALL FER MFR'5 REQ. ----.� CO,_1 GC S OFFICE r. Gatz -. 118 .. Y CTR... J Z 5 _ 0 s THr ° B ��Re VICINITY MAP z z 2B Il Ba' O - r - \ .... _.__ O O 0 OFFICE I'�,a U a N Q a xi a ryl - '---`_ === E DETECTCR ABOV HEAT DETECTOR ABOV sm t T-BAR CEILING B AK T-BAR CEILING OrF'CE O¢IGE m z DESIGNER OF RECORD MICHAELD°PAATkTERSON ELECTRIC 3.03 ROOM - RECSWNG mxl ) OPERATIONS MANAGER C - 15 1 4 �. z-xx FC901 Battery Calculetlone Workeheet VOLTAGE DROP W ORKSHEET FOR NOTIFIC'A I ION APPLIANCE CIRCUITS 10 BPO�EWAET,S 130 r - ®r _-.. . ..__ ___—_O FCB01 Panel StandD A) Alarm IA) Job Name: Csinook Lumber D PNONE.(eoalxeeazoeTE _ rl 1 Main Board 0.175 0.203 Formula R=V I vqx.(cool xee-zTu asSIGNERx.14B-t ' /E'X 4 DeNce Current Diaw 0.01906 0,01906 y EXIST HR FIRE WALL � \�� NAC1 0---- L415 Not3icatgnA plU s Qt Device Carlin Hom�Strobe 15cd Siemens' MC-C. Current Each: 0.087 A 4 AulhonA SlanetUIs WAREHOUSE NAC2 0 1.393 Device: Ceiling Horn Strobe 30cd S Current Each: 0.131A 1 2 Devices � Device: Ceiling Homy Strobe 95ed Siemens ZH.MC-C Current Each: 0.292 A 2 ' Device'. Celing Hom,Strobe 177ed Siemens ZH-HMC-C Current Each: 0.506 A 2 OH921 15 O.0045 0,OG45 Device: Ceging Strobe 15cd Siemens ZR-MC-C HI921 12 0.00336 0.00336 Current Each: Il g A 5 HMB/87005/D/M 8 0,0112 0.0112 Device Ceiling Strobe 30ed Siemens ZR-MC-C Cbtrent Each: 0.111 A 1 Totel 35 0.01908 0,01906 Device: Weatherproof Strobe 75cd Siemens ST-75-R-WP Qlrrent Each: 0.146A 1 Wire: 114Awg(NAC&ADA Circuit,) 3.072hms er 1000' er NEC Total Current 0.19706 3.03W6 Resisrancp er Notification Circuit Circuit Length-2 WQe Nominal Currenton Resistance Total Resist. 1_ x_p( x-xx Cx-Cj III! Standby nme 2a 4.728 Resistance Voltage Circuit from Device on Circuit NACd I 674 2 069 20.40 L415 0.069 2.139 _ 0 Alarm nme = 0.253 NACk2 488 1198 W40 1.393 1 0.068 1 1.566 w r F AH roquired Ina rerrva) d.982 Vdrop=1 X R Assu tans:Vchagc is 24VIX Entire Load Is A plied at End ofCircuit 1 I EP M Bette Re eerva 110% Voltage Drop Per Notification Appliance Circuit 0 M PROVIDE PULL STATIO PROVIDE PULL STATIO Current on Totai Resist NEXT TO EXIT NEXT TO EXIT AN Required(wlth rseerve 5.4801395 Circuit N Circuit an Circuit Voltage Loss Final Voltage Crcuit Within Device Battery Provided 7 AH NAC#1 1.415 2.139 eratin Ran se 16.33 VDC $ 3.03 17.37 Yes NAC9t2 .393 1.566 2.18 18.22 Yes g UI 1 E T NA42 (rvD 2.1e) 1771or Received 0 MAY 10 7D'I I' °z FIRE ALARM CABLE/LINETYPE LEGEND CABLE LINETYPE NFPAra CIRCUIT ttPE TYPICAL DENCES CONDUCTORS s uNE I NERNAuuu CHINOOK LUMBERB NACINOn IGAT ON APPLIAN TIPCUIT) MIDIBI UALQWCES(HORNSIBTR ( © O PROJECT TITLE %_I7f FIRE ALARM LEGEND FIRE ALARM PLAN SYMBOL EQUIPMENT MANUFACTURER PARTNUMBER BACKBOX RING MT.HEIGHT CITY, SHEET TITLE ® FIRE ALARM CONTROL PANEL SIEMENS FC901 FH901 N/A 72"TO TOP 1 4701 05/09/2017 ® SMOKE DETECTOR SIEMENS OH921 DBAI 1-GANG CEILING 15 JOB NO. DATE THERMAL DETECTOR SIEMENS HI921 DB-1I 1-GANG CEILING 12 �r MANUAL PULL STATION SIEMENS HMS-D 4/SQ. 1-GANG 48"TO TOP 8 DRAWN AAR CHECKED MDP ® STROBE SIEMENS ZR-MC-CW 4/SQ. 1-GANG CEILING 6 p(� HORN/STROBE SIEMENS ZH-MC-CW 4/SQ. 1-GANG CEILING 8 SCALE ae1 HIGH CANDELLA HORN/STROBE SIEMENS ZH-HMC-CW 4/SQ. 1-GANG CEILING 2 IF TH19 oRANANO IS NOT a4"z30"IT NAS BEEN REDUCED WEATHERPROOF STROBE 75CD SIEMENS ST-76-R.WP WPBBS.R COPYRIOH'r02001 FIREPOWER.INC. ' IB 1-GANG 98"TO BOTTOM 1 _ 1 END-OF-LINE DEVICE °� FA1 .0