HomeMy WebLinkAbout730 E HIGHLAND DR_BLD6808_2026 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 730 E HIGHLAND DR Permit#: 6808 Parcel#:31051100401000 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:PHASE 2 OF TENANT IMPROVEMENT OF EXISTING Valuation:440000.00 CHURCH BUILDING INCLUDING NEW FURNACES,NEW DOAS&DUCT HEATERS,COOLING COILS,AC UNITS,&CONDENSERS PER ENERGY CODE REQUIREMENTS.NEW DISTRIBUTION DUCTWORK,GRILLES, REGISTERS,&DIFFUSERS. APPLICANT , CONTRACTOR MARYSVILLE FREE METHODIST Johansen Mechanical Johansen Mechanical Inc CHURCH 6715 GROVE ST 16372 177th Ave SE 16372 177TH AVE SE MARYSVILLE,WA 98270 Monroe,WA 98272 MONROE,WA 98272 3607224310 425-481-2266 U0 600495164 EXP:06/30/2026 LIC:JOHANMI173PK EXP:02/02/2027 LIC:JOHANMI969P7 EXP:10/30/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL MECHANICAL CODE YEAR: 2021 STORIES: I CONST.TYPE: VA DWELLING UNITS: OCC GROUP: A-3;Assembly BUILDINGS: OCC LOAD: - PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBCl l0/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 11/19/2025 �-� 11/19/2025 Applicant Signature Date Building Official Date _ CONDITIONS Adhere to approved plans.Permit shall be onsite for inspections.Call for inspections. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. MEMP no PERMIT FEESIRM Date Description Fee Amount 11/19/2025 Web Only-Iv19chanical Commercial Plan Review $2,832.14 11/19/2025 Credit Card Service $84.96 11/19/2025 Processing/Technology $25.00 11/19/2025 Gras Fired NC>500 BTU/h $600.00 11/19/2025 Gas Piping/Units $33.00 11/19/2025 Ivlechanical Base $25.00 11/19/2025 rvbchanical Msc. $45.00 11/19/2025 Refrigeration Unit>500 BTU/h $800.00 Total Due: S4,445.10 Total Payment: $4,445.10 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail i COMMERCIAL MECHANICAL APPLICATION • Community&Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping and must be accompanied by ELECTRONIC CONSTRUCTION DRAWINGS and CUT SHEETS and/or information outlined in the MECHANICAL SUBMITTAL REQUIREMENTS,if applicable. Type of Permit: ❑ New Installation 0 Addition 0 Alteration ❑ Replaced ❑ Gas Piping Type I and Type II Hood Systems required submittal of the Commercial Mechanical Addenda Property Address: 730 E Highland Dr Project Valuation: 440,000.00 Lot#: n/a Parcel ID No.: 31051100401000 Preferred Contact: O Owner 0 Contractor Project Description: Rock Creek Church Tenant Improvement Phase 2 Owner Name: Rock Creek Church - Bryan Rees Office No.: (360) 659-7117 Email Address: n/a Cell No.: Mailing Address: 730 E Highland Dr City: Arlington State: WA Zip: 98223 Contractor Name: Johansen Mechanical Office No.: (425) 481-2266 Email Address: robj@johansenmech.com Cell No.: (360) 722-4310 Mailing Address: 16372 177th Ave SE City: Monroe State: WA Zip: 98272 L&I Contractor License Number: JOHANM1969P7 Expiration Date: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured per IFGS,Section 415 • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of each appliance Gas Piping Specification and complete Schematic PAGE 3 O Not Applicable O CSST O Brass O Other Proposed Piping Material: O Black Steel O Galvanized Steel Proposed Piping Size: O 1/2" O 5/8 O 3/4" O 1" O 11/z" O 2" O 3" Inlet Pressure: Pressure Drop: Specific Gravity: I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above described property will be in accordance with the laws,rules and regulation of the State of Washington. Rob Johnson Signature Print Name Date REV03.2022 Page 1 of 3 MECHANICAL PERMIT FEES (per unit Type of Fixture No.of Units Cost per Unit Subtotal Additional Plan Review fees 1 x $ 75.00 = $75 Air Conditioning Unit 15 100 Btu h x $ 15.00 = $ Air Conditioning Unit> 100 Btu h x $ 25.00 = $ Air Conditioning Unit> 500 Btu/hp x $ 50.00 = $ Air Handling Units x $ 15.00 = $ Base Mechanical Fee $ 25.00 $ 25.00 Boiler<100Btu h>3h x $ 15.00 = $ Boiler>1 million Btu/h<50hp x $ 25.00 = $ Boiler>1.5 million Btu/h<50hp x $ 50.00 = $ Boiler>100Btu h 3-15h x $ 15.00 = $ Boiler>500Btu h 15-30hp x $ 25.00 = $ Commercial Hoods-Type I x $ 25.00 = $ Commercial Hoods-Type II x $ 50.00 = $ Diffusers 1 x $ 15.00 = $15 Dryer Ducting x $ 15.00 = $ Ductwork(drawings required) 1 x $ 25.00 = $25 Evaporative Coolers x $ 15.00 = $ Exhaust Ventilation Fans x $ 15.00 = $ Fireplace/Insert/Stove x $ 15.00 = $ Forced Air Heat<_100 Btu h x $ 15.00 = $ Forced Air Heat>100 Btu h x $ 25.00 = $ Gas Clothes Dryer x $ 15.00 = $ Gas Fired Air Conditioning Unit 15 100 Btu h x $ 15.00 = $ Gas Fired Air Conditioning Unit> 100 Btu h x $ 25.00 = $ Gas Fired Air Conditioning Unit> 500 Btu/hp Btu/hp 12 x $ 50.00 = $600 Gas Pi in <_ 5 units 1 x $ 15.00 = $15 Gas Piping for each additional unit > 5 9 x $ 2.00 = $18 Heat Exchangers x $ 15.00 = $ Heat Pump-Condensing Unit x $ 25.00 = $ Hot Water Heat Coils x $ 15.00 = $ Miscellaneous Appliance-regulated by 3 x $ 15.00 = $45 DOAS mechanical code,not otherwise specified Package Units:5 100 Btu > 100 Btu x $ 25.00 $50.00 = $ Range/Cook top-Gas Fired x $ 15.00 = $ Refrigeration Unit<_100Btu h x $ 15.00 = $ Refrigeration Unit>100Btu h x $ 25.00 = $ Refrigeration Unit>500Btu h 16 x $ 50.00 = $800 Re-inspection fee all x $ 75.00 = $ Unit Heaters <_ 100 Btu h x $ 15.00 = $ Unit Heaters>100 Btu h x $ 25.00 = $ Variable Air Volume Boxes (part of Air x $ 10.00 = $ Conditioning System) Wall Heaters-Gas Fired x $ 25.00 = $ Water Heater- Gas Fired x $ 25.00 = $ Permit Fee $1618 Table 4-8; Plan Review Fee $ Processing/Technology Fee $25.00 Total $1643 REV2.2024 Page 2 of 3 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY 0 SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated PLEASE SEE ATTACHED ADDED M601 "ISOMETRIC GAS PIPING DIAGRAM". ISOMETRIC DIAGRAM IS TO SCALE REV2.2024 Page 3 of 3 1 2 3 4 5 G� AQUA AIR AQUA AIR ENGINEERING 12400 SE 38TH ST #50014 BELLEVUE, WA 98015 www.aquaairengineering.com 1-1/4"NG UBI: 605247933 (240 MBH) �� I l AH-M103 RELOCATE EXISTING GAS WATER l CONSULTANTS HEATERS AS REQUIRED. 2"NG l AH-M104 RECONFIGURE EXISTING NATURAL (400 MBH) AH-M105 GAS AND FLUE VENT 2"N G CONNECTIONS. \ (640 MBH) AH-M106 °� l 1-1/4"NG AH-M107 w\ (240 MBH)>- AH-M108 3/4"NG AH-M109 1"NG (-60 MBH) AH-M110 �� AH-M101 � 1"NG 1/2"NG AT 7"W.C.TO IANj N 2-1/2"NG c �\ (-120 MBH) 1/2"NG DISHWASHER ,Q�OFwAS"' 0, (880 MBH) �\ AH-M111 (-40 MBH) Q y•/ 2"NG AT 7"W.C. \ 1/2"NG 53350 1"NG �I TO EXISTING (-30 MBH)/ � ���cSSGISTER���� (80 MBH) GAS WATER \ �ON4 HEATERS / AH-M112 GAS SHUTOFF 2"NG �rl VALVE g (-60 MBH) 1"NG 1"NG AT 7"W.C.TO PHASE 2 ROCKCRFFK CHURCH ARLINGTON C 2-1/2"NG 2"NG (--140 MBH) EXISTING RANGE& C 730 F HIGHLAND DRIVE (-130 MBH) OVEN ARLINGTON, WA 98223 (960 MBH) MECHANICAL DRAWINGS € 1/2"NG AT 7"W.C.TO FIREPLACE OWNER 2"NG (-30 MBH) MARYSVILLE FREE METHODIST CHURCH 6715 GROVE ST, (-270 MBH) MARYSVILLE, WA 98270 2-1/2"NG (960 MBH) MEDWrJL CONIRACIOR 3"NG 1/2"NG (1,230 MBH) (--45 MBH) � 1/2"NG AT 7"W.C.TO EXISTING GAS B FURNACE \ B �� C/1 3"NG (1,275 MBH) � a O 1"NG AT 7"W.C. a J 06 24 25 MECHANICAL 30%DO SET 0 MECHANICAL 65%DO SET 10 23 25 MECHANICAL PERMIT SET 1 MECHANICAL PERMIT REVISION SEr I� MARK DATE DESCRIPTION PROJECT NO: 2025-021 CONNECT NEW 3"NG AT EXISTING METER. EXISTING GAS METER. cAD DWG nm M601.Dwc LONGEST LINE LENGTH OF 250 FT AT (TYP 2) DRAWN BY: OWN A 7"W.C.COORDINATE WITH UTILITY 1° 3' 5' 10' 15, 25' A CHK'D BY: DWN COMPANY AS REQUIRED. SCALE: A"=1' COPYRIGHT: 2' 4' SHEET nU o ISOMETRIC GAS PIPING DIAGRAM 1 2 3 4 5 P601 SHEET 15 OF 15 1 1 2 1 3 4 1 5 MECHANICAL ABBREVIATIONS MECHANICAL LEGEND GENERAL NOTES PARCEL NUMBER G`: AQUA AIR A AMPS IBC INTERNATIONAL BUILDING CODE 10"X1 O" RECT SUPPLY AIR DUCT 1. ALL WORK SHALL COMPLY WITH THE 2021 WASHINGTON STATE BUILDING CODE,2021 WASHINGTON STATE 31051100401000 AC AIR CONDITIONING ICW INDUSTRIAL COLD WATER 1O"X1O" RECT URD MECHANICAL CODE,2021 WASHINGTON STATE PLUMBING CODE,2021 WASHINGTON STATE ENERGY CODE, AQUA AIR ENGINEERING ACH AIR CHANGES PER HOUR ID INSIDE DIAMETER/DIMENSION UP/TOWARD 1 AND OTHER APPLICABLE FEDERAL,STATE,OR LOCAL CODES AS ADOPTED AND ENFORCED BY THE LOCAL ACT ACOUSTICAL CEILING TILE IE INVERT ELEVATION JURISDICTION.IN CASE THE PLANS SHOW MORE STRINGENT REQUIREMENTS,THE PLANS SHALL GOVERN THE 12400 SL 38TH ST 1r 500 1 4 AD ACCESS DOOR JEER INTEGRATED ENERGY EFFICIENCY RATIO 10"X10" RECT SUPPLY AIR DUCT DESIGN,YET NOTHING ON THE DESIGN DOCUMENTS SHALL BE INTERPRETED AS AUTHORITY TO VIOLATE LEGAL DESCRIPTION BELLEVUE, WA 98015 10"X10" DN AWAY CODE(S)OR REGU ATION(S). ADD'L ADDITIONAL IMC INTERNATIONAL MECHANICAL CODE �© / SEC 11 TWP 31 RGE 05 BEG 1/4 COR E BDY 11-31-05 TH SLY ALG E LN SD www.aquaairengineering.com AFF ABOVE FINISHED FLOOR IN INCHES 10"XIO° 2. SUBMISSION OF BID IN CONNECTION WITH THIS WORK SHALL IMPLY THAT THE BIDDER HAS EXAMINED THE UBL 605247933 AFG ABOVE FINISHED GRADE IN WG INCHES WATER GAUGE RECT RETURN DUCT JOB SITE UNDER WHICH THE CONTRACTOR WILL BE OBLIGATED TO OPERATE UNDER THIS CONTRACT.NO SEC LN 20.03FT TH ANG R 87*0612 120.04FT TO TPB TH CONT ON LAST AHU AIR HANDLING UNIT IPLV INTEGRATED PART LOAD VALUE TOWARD UP 10"X10" / EXTRA CHARGE WILL BE ALLOWED FOR FAILURE OF ANY BIDDER TO EXAMINE THE SITE PRIOR TO BID. �® DESC COURSE 180FT TH ANG L 87 06 12 150FT TH ANG L 92 53 48 D ALUM ALUMINUM KW KILOWATTS D AMP/AMPS AMPERAGE LAT LEAVING AIR TEMPERATURE 10"X1O" RECT RETURN DUCT 3. WHERE USED,THE TERM"PROVIDE"SHALL MEAN"FURNISH AND INSTALL". 180FTTH ANG L 87*06 12 15OFT TO TPB TGW COM NE COR NE1/4 NE1/4 CONSULTANTS AP ACCESS PANEL L /L 6S POUND/POUNDS miicO"© DN/AWAY 4. IN THE EVENT OF A CONFLICT OR INCONSISTENCY BETWEEN ITEMS INDICATED ON DRAWINGS AND TH W ALG N LN SD SUB 392.88FT M/L TH ANG L 81*48 49 DIST 169.92FT ARCH ARCHITECT LF/LIT FT LINEAL FOOT/FEET SPECIFICATIONS WITH CODE REQUIREMENTS,THE MORE STRINGENT STANDARD SHALL PREVAIL. BC BEADED COLLAR LPG LIQUID PROPANE GAS 10°X10" RECT EXHAUST SPECIFICATIONS TH CONT SLY 297FT TH E TAP ON E LN 465.03FT S OF NE COR TH N BDD B DAMPER LPG LOW PRESSURE STEAM 10"X10" UP/TOWARD 5. CARE SHALL BE EXERCISED TO MINIMIZE ANY INCONVENIENCE OR DISTURBANCE TO OTHER AREAS OF THE ALG E LNTAP 170.03FT S OF NE COR SD SUBTH WILY TO TPB&TGW BAAP BF BELOWELOW FLOOR LVG LEAVING BUILDING WHICH ARE TO REMAIN IN OPERATION.ISOLATE WORK AREAS TO KEEP DUST AND DIRT WITHIN THE BHP BRAKE HORSEPOWER LWA SOUND POWER RATING LEVEL(IN DB) 10"X1o^ CONSTRUCTION AREA. 20FT S&393FT W OF 1/4 COR ON E LN SEC TH S 455.6FT TH W 20OFT TH N BLDG BUILDING LWG LOW WALL GRILLE RECT EXHAUST BOD BOTTOM OF DUCT LWT LEAVING WATER TEMPERATURE 10'X�o© DN/AWAY 6. NO PIPING,EQUIPMENT,ETC.SHALL BE REMOVED,DISCONNECTED OR SHUT DOWN WITHOUT PRIOR REVIEW 285.6FT THE 100FT TH N 115.6FT TH E 100FT TPB LESS RD&LESS V 864 P BOP BOTTOM OF PIPE MAX MAXIMUM WITH THE OWNER TO CONFIRM THAT AREAS TO REMAIN IN OPERATION WILL NOT BE AFFECTED.IF ANY AREAS BOT BOTTOM MAU MAKE UP AIR UNIT NOT WITHIN THE SCOPE OF WORK ARE AFFECTED BY ANY SHUTDOWN,REMOVAL OR DISCONNECTION, 490FOR CITY ST LESS RD R/vv^, TO CITY OF ARL PER OCD REC AFN BS BIRD SCREEN BLACK STEEL MBH 1000 BRITISH THERMAL UNITS HOUR ROUND DUCT- UP/TOWARD SUFFICIENT ADVANCE NOTICE MUST BE GIVEN TO THE OWNER INDICATING WHICH AREAS WILL BE AFFECTED, / / ® /' WHEN THE PROPOSED SHUTDOWN WILL OCCUR,AND FOR HOW LONG A PERIOD OF TIME. 9809220489(EXEMPT PER ST OF WA REG#01414-001) BTU BRITISH THERMAL UNIT MCA MINIMUM CIRCUIT AMPACTIY BTUH BRITISH THERMAL UNITS PER HOUR MD MOTORIZED DAMPER 1p"0 i/ 7. THE ARRANGEMENT OF EQUIPMENT AND PIPING SHOWN ON THE DRAWINGS IS BASED UPON INFORMATION \ CAP CAPACITY MDR MANUFACTURER 1 0 ROUND DUCT- DN AWAY ' ` � �� / AVAILABLE TO THE ENGINEER AT THE TIME OF DESIGN AND IS NOT INTENDED TO SHOW EXACT DIMENSIONS. CBD CALIBRATED BALANCING DAMPER MISC MISCELLANEOUS �J THIS CONTRACTOR SHALL VERIFY ALL DIMENSIONS AT THE SITE MAKING FIELD MEASUREMENTS AND SHOP �p Regso'0 \LLIA17� CG CONTROLS CONTRACTOR MIN MINIMUM/MINUTE DRAWINGS NECESSARY FOR FABRICATION OR ERECTION OF HVAC SYSTEMS.MAKE ALLOWANCE FOR BEAMS, F WAS O 12"X10"0 FLATOVAL DUCT- UP/TOWARD ( e� CD CEILING DIFFUSER/CONDENSATE DRAIN MPS MEDIUM PRESSURE STEAM � PIPES AND OTHER oasraucrionis IN BUILDING conlsTRucnoN.CHECK DRAWINGS sFIowING WORK OF CDWR CONDENSER WATER RETURN MT MOUNT OTHER TRADES AND CONSULT WITH THE OWNER'S REPRESENTATIVE IN THE EVENT OF POTENTIAL w CDWS CONDENSER WATER SUPPLY MTD MOUNTED 12 X10"0 FLATOVAL DUCT- DN/AWAY �° GT�ON INTERFERENCE.SHOP DRAWINGS SHALL BE MINIMUM 1/4"=1'-0"SCALE,INDICATING FITTINGS,SIZES,WELDS CFM CUBIC FEET PER MINUTE MUW MAKE-UP WATER T1.1AND CONFIGURATIONS AND SUBMITTED TO ENGINEER FOR REVIEW. Arlington LV Heights 53350 CHI CHILLED WATER RETURN NA NOT APPLICABLE RE0STeR�� CHWS CHILLED WATER SUPPLY NC NORMALLY CLOSED NOISE CRITERIA 10^�o DUCT OVERLAP g. THIS CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER TRADES PRIOR TO FABRICATION, rlingtorl �cs �G / PURCHASE AND/OR INSTALLATION OF ALL WORK I `- Arlington Hardware S/ONA�E CLG CEILING NG/NGAS NATURAL GAS 10^0 T`-., 8Lum6e,Inc. COL COLUMN NIC NOT IN CONTRACT BOOT TAP 9. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT COMPLIANCE WITH THE MANUFACTURER'S WRITTEN CONIC CONCRETE NO NORMALLY OPEN/NUMBER 10°0 INSTRUCTIONS. s==_- _ • COND CONDENSATE NPW NON-POTABLE WATER - PHASE 2 ROCKCREEK CHURCH ARLINGTON CONN CONNECT/CONNECTED/CONNECTION N-R NON-RESIDENTIAL 10°� 45•TAP 10. THIS CONTRACTOR SHALL NOT BORE,NOTCH,CUT,OR PENETRATE INTO A STRUCTURAL MEMBER WITHOUT (�Safeway River CONTINUATION OA OSA OUTSIDE AIR WRITTEN APPROVAL FROM A DESIGNATED STRUCTURAL ENGINEER ANDTHE OWNER. Meadows© 73O E HIGHLAND DRIVE CONT CONTINUOUS/ /C U CONTR CONTRACTOR OBD OPPOSED BLADE DAMPER ` COORD COORDINATE OD OUTSIDE DIAMETER/DIMENSION 10"� VOLUME DAMPER INSTALL MANUAL VOLUME DAMPERS WITHIN DUCT BRANCHES TO BALANCE AIRFLOW CFM.ON INSULATED County Park ARLINGTON, WA 98223 COP COEFFICIENT OF PERFORMANCE PCF POUNDS PER CUBIC FOOT 1010Oq DUCTS,MOUNT DAMPER REGULATOR ON 2"STAND-OFF BRACKET TO CLEAR INSULATION. MECHANICAL DRAWINGS CT COOLING TOWER PD PRESSURE DROP 10 12. COORDINATE ACCESS TO EQUIPMENT WITH WORK OF OTHER TRADES.PROVIDE DUCT ACCESS DOORS AND v OWNER CU CUBIC CONDENSER UNIT PH PHASE CALIBRATED BALANCING DAMPER \pC / �� CEILING ACCESS DOORS TO ALLOW ACCESS FOR FILTER CHANGEOUT,CONTROLS ACCESS AND ACCESS TO Aflington MARYSVILLE FREE METHODIST CHURCH CW DOMESTIC COLD WATER/CONDENSER WATER POC POINT OF CONNECTION RISE(R)& DROP(D) SERVICE/REMOVE COMPONENTS INCLUDING,BUT NOT LIMITED TO,FANS,PULLEYS,SHEAVES,BELTS,ETC. Municipal 6715 GROVE ST, DB DUCTBOARD/DRY BULB/DECIBEL P/PRESS PRESSURE Airpot 0 13. PROJECT CLOSE OUT DOCUMENTATION AND TRAINING OF BUILDING OPERATIONS PERSONNEL IS REQUIRED (AWO) DDC DIRECT DIGITAL CONTROL PSI POUNDS PER SQUARE INCH TRANSITION � �'it DEFL DIEFLECTION PGIG POUNDS PER SQUARE INCH GAUGE MARYSVILLE, WA 98270 FOR ALL MECHANICAL COMPONENTS,EQUIPMENT AND SYSTEMS PER WSEC C103.6. A DEG DEGREE/DEGREES QTY QUANTITY TURNING VANES/SPUTTERS 14. CONSTRUCTION TO ADHERE TO BUILDING STANDARDS AS APPLICABLE.FLEX DUCT TO BE MAXIMUM 12 FEET MECHANICAL CONTRACTOR DIA DIAMETER R RETURN GRILLE/RELOCATED/RETURN Pr IN LENGTH FLEX DUCT MAYBE UP TO 25 FEET LONG IF SIZED UP ONE SIZE, DMPR DAMPER RA RETURN AIR DUCT MOUNTED SMOKE DETECTOR VICINITY MAPI) DN DOWN RD/RND ROUND t BACK DRAFT DAMPER NO SCALE ISM DOAS DEDICATED OUTSIDE AIR SYSTEM REF REFERENCE DWG DRAWING REQ REQUIRED FLEXIBLE DUCT S H E ET I N D EX EXH EXHAUST RESID RESIDENTIAL AIR FLOW FORCED AIR ( ) EA EACH RF RELIEF SHEET DESCRIPTION REV � EAT ENTERING AIR TEMPERATURE RG REFRIGERANT DISCHARGE GAS Moot GENERAL NOTES,LEGEND,SHEET INDEX AND ABBREVIATIONS E Highland or E Highlard Or :NNW EC EGGCRATE GRILLE/END CAP/ELEC CONTRACTOR RL REFRIGERANT LIQUID EER ENERGY EFFICIENT RATING RPM REVOLUTIONS PER MINUTE Mooz SCHEDULES SHEET EF EXHAUST FAN IRS REFRIGERANT SUCTION EFF EFFICIENCY S SUPPLY COMBINATION FSD M003 SCHEDULES SHEET �y FIRE DAMPER EL ELEVATION SA SUPPLY AIR Moo4 SCHEDULES AND CALCULATIONS SHEET COO ELEC/ELECT ELECTRICAL/ELECTRIC SAT SATURATION/SUPPLY AIR TEMPERATURE SMOKE DAMPER EMCS ENERGY MANAGEMENT CONTROL SYSTEM SD SMOKE DETECTOR MOTOR OPERATED DAMPER MD201 LEVEL MECHANICAL DEMO PLAN - ENT ENTERING S/D SUP& DRIVE CONNECTION- ACOUSTICALLY LINED DUCT MD202 MEZZANINE LEVEL MECHANICAL DEMO PLAN EQUIP EQUIPMENT S-C SEATTLE_CODE OD = OUTSIDE DIMENSIONS ESP EXTERNAL STATIC PRESSURE SEER SEASONAL ENERGY EFFICIENCY RATING SL=SOUND LINING (THICKNESS) M201 LEVEL 1 MECHANICAL HVAC PLAN B EWT ENTERING WATER TEMPERATURE SENS SENSIBLE ._, i� B MP201 LEVEL 1 MECHANICAL PIPING PLAN IXIST/(E) EXISTING SL SOUND LINED ® CLEARANCE _ EXH EXHAUST SM SHEETMETAL ® SUPPLY AIR DIFFUSER M202 MEZZANINE LEVEL MECHANICAL HVAC PLAN -' �1 F FAHRENHEIT SPEC SPECIFICATION _ FAC FIRE ALARM CONTRACTOR SO SCREENED OPENING (WITH CORE BLANKOFF/ROTATE) MP202 MEZZANINE LEVEL MECHANICAL PIPING PUN FD FIRE DAMPER SOG SLAB ON GRADE ® CEILING EXHAUST AIR GRILLE M203 ROOF MECHANICAL PLAN A FDC FIRE DEPARTMENT CONNECTION SP STATIC PRESSURE 11 n°is r FF FINISHED FLOOR SF SQUARE FEET CEILING RETURN OR TRANSFER M401 MECHANICAL ELEVATIONS PLAN L FIC FURNISHED AND INSTALLED BY CONTRACTOR SS STAINLESS STEEL AIR GRILLE FIO FURNISHED AND INSTALLED BY OWNER STRUC STRUCTURAL o SLOTTED DIFFUSER (PLAN VIEW) M501 DETAILS SHEET It r06. O FLA FULL LOAD AMPS TA TRANSFER AIR M502 DETAILS SHEET FLEX FLEXIBLE TEMP TEMPERATURE/TEMPORARY x REVISION CLOUD&TRIANGLE FLR FLOOR TBD TO BE DETERMINED "0 ROUND DUCT SYMBOL FOB FLAT ON BOTTOM TOD TOP OF DUCT ##X# '0 FLATOVAL DUCT SYMBOL FDIC FURNISHED BY OTHERS, TOS TOP OF STEEL/TOP OF SLAB DEGREES SYMBOL INSTALLED BY CONTRACTOR TOT TOTAL A POINT OF CONNECTION FOS FLAT ON SIDE TSP TOTAL STATIC PRESSURE CD1-100 GIRD TAG IDENTIFIER = TYPE-CFM FOT FLAT ON TOP TSTAT THERMOSTAT 8"0 SIZE SITE MAP FP FIRE PROTECTION TYP TYPICAL QT TSTAT/TEMP SENSOR ®o CARBON DIOXIDE NO SCALE FPM FEET PER MINUTE UH UNIT HEATER QH HUMIDITY SENSOR SENSOR 06 za zs MEOHANICAL 30%DO SET FT FOOT/SMOTE DAMPER LINO UNLESS NOTED OTHERWISE sD SMOKE DETECTOR CO CARBON MONOXIDE a 23 zs MEcHANCA PERMIT SET VOLT FLIT FUTURE VD VOLUME DAMPER SP STATIC PRESSURE SENSOR SENSOR MINIMUM PIPE INSULATION FV FACE VELOCITY VEL VELOCITY 0 OCCUPANCY SENSOR ®SENSOR FLUID DESIGN IN CONDUCTIVITY NOMINAL PIPE DIAMETER(INCH) G GRILLE VERT VERTICAL O OPERATING CONDUCTIVITY MEAN TEMP 1 TO 1-1/2 TO 4 TO MARK DATE DESCRIPTION GA GAUGE/GALLON VFD VARIABLE FREQUENCY DRIVE TEMP°F RANGE RATING°F 1 1-1/2 <4 <8 4 GALV GALVANIZED VOL VOLUME EXISTING DUCTWORK HEATING SYSTEMS*(STEAM,CONDENSATE,HYDRONIC HOT WATER,DOMESTIC HOT WATER,DOMESTIC HOT WATER RECIRCULATION) PROJECT NO: 2025-021 GC GENERAL CONTRACTOR W WRAPPED DUCT DEMO DUCTWORK >350 0.32-0.34 250 1 4.5 1 5 1 5 5 5 CAD DWG FILE: moo'DwG GPM GALLONS PER MINUTE WB WET BULB 251-350 0.29-0.32 200 3 4 4.5 4.5 4.5 DRAWN B1': OWN GIRD GRILLE/REGISTER/DIFFUSER WG WATER GAUGE �I WALL-MOUNTED GRILLE 201-250 0.27-0.30 1H 2.5 2.5 2.5 3 3 A GWB GYPSUM WALL BOARD W/ WITH 141-200 0.25-0.29 125 1.5 1.5 2 2 2 City of Arlington A CHK'D LTr: DWN HD HEAD W/o WITHOUT c, PIPE ELBOW UP 105-140 0.21-0.28 100 1 1 1.5 1.5 1.5 Building Department COPYRIGHT: �o PIPE ELBOW DN 9 p HQRIZ HORIZONTAL W/SF WATTS PER SQUARE FOOT DOMESTIC COLD WATER AND HORIZ RAIN LEADERS TO VERTICAL RAIN LEADER(TO PREVENT CONDENSATION ONLY) HP HORSEPOWER WSEC WASHINGTON STATE ENERGY CODE DIRECTION OF FLOW NA 0.21-0.27 75 0.5 0,5 1 1 1 APPROVED SHEET TILE HR HOUR DIRECTION OF SLOPE DOWN COOLING SYSTEMS*(CHILLED WATER,BRINEAND REFRIGERANT,WATERSIDE ECONOMIZER SYSTEMS**) HSPF HEATING SEASONAL PERFORMANCE FACTOR PLUG OR CAP 40-60 0.21-0.27 1 75 1 0.5 0.5 1 1 1 Kevin Olander- 11/18/2025 GENERAL NOTES, HT HEIGHT 2-CHWS/tHWR5 CHILLED WATER SUPPLY/RETURN 40 0.20-0.26 75 0.5 1 1 1 1.5 No changes authorized unless approved by HWTG HIGH WALL TRANSFER GRILLE z-REAS- REFRIGERANT LIQUID/SUCTION the Buildin Official LEGEND SHEET INDEX HWR HOT WATER RETURN NG NATURAL GAS *NOT REQUIRED FOR STRAINERS,CONTROL VALVES&BALANCING VALVES ASSOCIATED WITH PIPING 1"OR LESS IN DIA. g ° r HWS HOT WATER SUPPLY LPG LIQUID PROPANE GAS -TYPICAL CONDENSER WATER PIPE IN NON-ECONOMIZER SYSTEMS IS NOT INSULATED AND AB B R EVIATI O N S HX HEAT EXCHANGER 2-CCIWS/CCIWR-5 CONDENSER WATER SUPPLY/RETURN SEE R403 FOR RESIDENTIAL INSTALLATIONS HZ HERTZ HEATING WATER SUPPLY/RETURN 1 2 3 4 5 M001 SHEET 1 OF 1 2 3 1 4 5 ENERGY RECOVERY VENTILATOR SCHEDULE G AQUA AIR TIME OUTSIDEAIR EXHAUST AIR ELECTRICAL ENTHALPY EQUIP AQUA AIR ENGINEERING UNIT AREA OF EAT"F LAT"F EAT°F LAT°F FAN PER MOTOR OVERALL CORE WGT TAG LOCATION SERVED BASIS OF DESIGN YEAR CFM DB WB DB WB CFM DB WE DB WB V/PH BHP HP ESP TSP WICFM CTRL FLA MCA FLA MCOP EFF% LBS NOTES 12400 SE 38TH ST #50014 SANCTUARY& RENEWAIRE SUM 2,100 80.8 63.8 77 62.6 2,100 75 62.5 - - 64% BELLEVUE, WA 98015 DOAS-Mi MEZZANINE FOYER HE-3XJINV-S15WW WIN 2,100 25.5 21.2 58 43.4 2,100 70 51.3 - - 20811 1.17 3 1.5 2.2 0.42 VFD 7.3 28.4 14.6 40 69% 754 1-12 WWW.aqu001rengineering.com -DWNT---L - - - UBI: 605247933 SANCTUARY& RENEWAIRE SUM 2,100 80.8 63.8 77 62.6 2,100 75 62.5 - - 64% D DOAS-M2 MEZZANINE FOYER HE-3XJINV-S15WW WIN 2,100 25.5 21.2 58 43.4 2,100 70 51-3 - - 208/1 1.17 3 1.5 2.2 0.42 VFD 7.3 28.4 14.6 40 69% 754 1-12 D -DWNT---L DAIKIN SUM 170 86 67 170 75 62.5 OONSULTMTTS DOAS-3 OFFICE OFFICE VAM300GVJU WIN 170 24 20 170 70 60 208/1 307 W 0.16 C403.8.1 ECM 1.6 15 71 GENERAL: ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION& INSTALL PER MANUFACTURERS REQUIREMENTS NOTES: 1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTECTION DIRECTION FOR EQUIPMENT AS REQUIRED BY LATEST APPROVED VERISON OF THE NATIONAL ELECTRICAL CODE,PRIOR TO ORDER. MANUFACTURER TO PROVIDE SCCR LISTING(5 KAIC MINIMUM OR PER ELECTRICAL CONTRACTOR CALCULATION)INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. 2 ULIETL LISTED UNTT.SUPPLYAND EXHAUST FAN MOTORS TO BE CAPABLE OF ADJUSTABLE SPEEDS. 3 PROVIDE FACTORY SUPPLIED AND MOUNTED VFD DRIVES FOR BOTH SUPPLYAND EXHAUST FAN TO ACCOMMODATE FILTER LOADING 4 MFG TO PROVIDE 2"FILTER RACK WHERE AVAILABLE AS ACCESSORY FOR MERV-8 FILTERS FOR OUTSIDE AIRFLOW SYSTEM AND MERV-8 FILTERS FOR EXHAUSTAIRFLOW SYSTEM. 5 PROVIDE FLOOR CURB FOR UNIT MOUNTING 6 WITH OUTDOOR AIR MONITORING SYSTEM,EBTRON AIR-IQ AFMD OR EQUAL(PROVIDED AND INSTALLED BY CONTROLS CONTRACTOR) 7 UNIT TO OPERATE CONTINUOUSLY DURING OCCUPIED HOURS,DECOUPLED FROM CENTRAL SYSTEM PER C403.6.2 8 MINIMUM UNIT EFFICIENCY TO MEET THE ENERGY CODE TABLEC403.5.1 9 INSULATE OSA INTAKE AND EXHAUST DUCTWORK FROM EXTERIOR UP TO THE ERV UNIT,AND SUPPLY DUCTWORK IF LEAVING TEMPERATURE IS<55'F Q of wnsyti O,p 10 PROVIDE SEISMIC BRACING PER ACSE 7,UNLESS:UNIT<20 LBS OR IS RIGID MOUNTED INLINE WITH DUCT(NO FLEX)AND<75 LBS OR<400 LBS WITH FLEX CONN'S&Ip=1.0&4'MAX MOUNT HEIGHT AFF 11 UNIT WITH FIXED PLATE HEAT EXCHANGER w _ 12 SUPPLY FAN AND EXHAUST FAN SPEED LINKED TO STATIC PRESSURE SETTING IN SA DUCT.STATIC PRESSURE SETTINGS TO MATCH ASHRAE GUILDINE 36 FOR VAV SUPPLY AHU AT a0.06"WC AND MAX•0.13"WC. 53350�EGISTER�� ass/ONAIL DUCT HEATER SCHEDULE 1012S/g UNIT MANUFACTURE HEATER TOTAL TEMP WINTER TSTAT DUCT DIMENSION ELECTRICAL WEIGHT TAG LOCATION SERVES &MODEL KW CFM RISE"F LAT"F LOCATION WIDTH(IN) HEIGHT(IN) FLA VIPH MOCP LBS NOTES PHASE 2 ROCKCREEK CHURCH ARLINGTON DH-M1 MEZZANINE DOAS-MI RENEWAIRE EK-1611004SCCVR 4 2100 6.0 61.0 IN HEATER 16 12 19.23 20811 25 1,2,3,4,5,6,7,8 (� 730 E HIGHLAND DRIVE C SPIRAL MOUNT REGISTER SCHEDULE DH-M2 MEZZANINE DOAS-M2 RENEWAIREEK-1611004SCCVR 4 2100 NHEATER 16 12 19.23 20811 25 1,2,3,4,5,6,7,8 ARLINGTON, WA 98223 UNIT BASIS OF DUCT MAX CORE FACE THROW GENERAL MECHANICAL DRAWINGS TAG DESIGN INMN8 CFM SIZE SIZE 9/10/15 23 MOUNTING MATERIAL REMARKS ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS ELECTRICAL,WEIGHT,SIZE,ETC...WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL PER MANUFACTURERS REQUIREMENTS SMi SHOEMAKER RS34 MIN8 150 12 X4 14X6 9110/15 23 DUCT STEEL 1,2,3,4,5 ( ) OWNER SM2 SHOEMAKER RS34 MIN 10 225 12X6 14X8 12/13118 20 DUCT STEEL 1,2,3,4,5 1 ELECTRICAL CONTRACTORTO PROVIDE SCCR PROTECTION DIRECTION FOR EQUIPMENTAS REQUIRED BY LATESTAPPROVED VERISON OF THE NATIONAL ELECTRICAL CODE,PRIOR TO ORDER. MARYSVILLE FREE METHODIST CHURCH SM3 SHOEMAKER RS34 MIN 10 350 16 X 6 18 X 8 15/17/23 26 DUCT STEEL 1,2,3,4,5 MANUFACTURER TO PROVIDE SCCR LISTING(5 KAIC MINIMUM OR PER ELECTRICAL CONTRACTOR CALCULATION)INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. 6]15 GROVE ST, SM4 SHOEMAKER RS34 MIN 12 450 16 X 8 18 X 10 17/19/26 25 DUCT STEEL 1,2,3,4,5 2 PROVIDE(NEMA 1 RATED STANDARD INDOOR/NEMA 4 RATED ENCLOSURE FOR OUTDOORNdATER PROTECTION)ENCLOSURE SMS SHOEMAKER RS34 MIN 12 525 18X8 20X10 17/20/27 25 DUCT STEEL 1,2,3,4,5 3 PROVIDE(SLIP IN/FLANGED/COLLAR)CONNECTION,AIR FLOW SWITCH,THERMAL CUTOFF PROTECTION,(MAGNETIC/MERCURY)CONTACTORS, MARYSVILLE, WA 98270 SM6 SHOEMAKER SD34 MIN 150 12 X4 14 X6 9/10/15 23 DUCT STEEL 1,2,3,4,5 4 PROVIDE24V CONTROL TRANSFORMER,(ELECTRONICISCR)CONTROLS,(DUCTIROOM)T'STAT SETAT60-F SM7 SHOENIAKERSD34 MIN 10 225 12 X6 14X8 12/13/18 20 DUCT STEEL 1,2,3,4,5 5 PROVIDE DISCONNECT SWITCH SM8 SHOEMAKER SD34 MIN 10 350 16 X6 18 X8 15/17/23 26 DUCT STEEL 1,2,3,4,5 6 INTERCONNECTION CONTROL WIRING BETWEEN AIR DELIVERYUNFS(TRANSFER FAN)AND HEATERS BYCONTROLS CONTRACTOR MECHANICAL CONTRACTOR SM9 SHOEMAKER SD34 MIN 12 450 16 X 8 18 X 10 17/19/26 25 DUCT STEEL 1,2,3,4,5 7 HEATING FAN SHALL SHUT OFF WHEN THERE IS NO CALL FOR HEATING AND COOLING IN THE ZONE PER 2021 WSEC C403.3.5.2,EXCEPT IF HEATING FAN<0.12W/CFM SM10 SHOEMAKER SD34 MIN 12 1 525 1 18 X 8 20 X 10 17/20/27 1 25 1 DUCT I STEEL 1,2,3,4,5 8 HEATING CONTROLS BY SCR HEAT GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS �M U PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL PER MANUFACTURERS REQUIREMENTS REMARKS: 1 PROVIREFER ODRWING WITH SED FORDUEDAMPERIZEDIA DIAMETER INDOOR FAN COIL UNIT SCHEDULE 2 REFER TO DRAWINGS FOR DUCT SIZE DIAMETER TO BE ATTACHED TO(MUST EXCEED CORE HEIGHT BY 4"MINIMUM) 3 STANDARD GALVANIZED FINISH,CUSTOM COLORS ONLY IF SPECIFIED BYARCHITECT ASSOCIATED ESP COOLING REFRIGERANT CONNECTION �I 4 REGISTER SHALL BE SIZED FOR CORE SIZE AND SPIRAL DUCT DIAMETER UNIT MANUFACTURE OUTDOOR OSA IN CAPACITY MBH[31 SUCT LID DRAIN ELECTRICAL SOUND WEIGHT 5 THROW BASED ON 100 FPM TERMINAL VELOCITY TAG LOCATION SERVES &MODEL TYPE UNIT CFM CFM WG TOTAL SENS. IN IN IN MCA I VIPH dBA LBS NOTES �I IU-101 OFFICE 123 OFFICE GOODMAN AHVE24BP1300 DUCTED ODU-101 800 170 0.6 23.9 =.73"J5 3/4 318 3/4 4.9 208/1 115 1,2,3,5,6,7,9,10,11 ^�^ ,,) IU-102 GREEN RM 114 AV SYSTEM DAIKIN FTX30WVJU9 WALL ODU-102 727 - 0.6 31.4 31.4 5/8 114 3/4 208/1 47 38 1,2,3,4,6,8,9,10,11 V GENERAL ALL TRADESTO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION& ROUND DIFFUSER SCHEDULE INSTALL PER MANUFACTURERS REQUIREMENTS UNIT BASIS OF NECK MAX OPENING OUTSIDE 1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTECTION DIRECTION FOR EQUIPMENT AS REQUIRED BY LATEST APPROVED VERISON OF THE NATIONAL ELECTRICAL CODE,PRIOR TO ORDER. TAG DESIGN TYPE SIZE CFM 0INCH 01NCH NC MOUNTING MATERIAL REMARKS MANUFACTURER TO PROVIDE SCCR LISTING(5 KAIC MINIMUM OR PER ELECTRICAL CONTRACTOR CALCULATION)INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. ^y B RD1 TITUSTMRA ROUND CEILING 6" 140 12 131/2 25 EXPOSED STEEL 1,2 2 R-32 REFRIGERANT,VERIFY MAXIMUM TOTAL SYSTEM REFRIGERANT LINE LENGTH AND MAXIMUM LIFT WITH MANUFACTURER/VENDOR.VERIFY ACCEPTABLE REFRIGERANT LINE SIZING,LENGTHS AND LIFTS WITH B ice) RD2 TITUSTMRA ROUND CEILING 8" 240 16 18 26 EXPOSED STEEL 1,2 MANUFACTURER PROVIDED SIZING PROGRAM RD3 TITUSTMRA ROUND CEILING 10" 350 20 221/2 24 EXPOSED STEEL 1,2 3 PRESSURE TEST REFRIGERANT PIPING AT 600 PSI �1 RD4 TITUS TMRA ROUND CEILING 12" 510 24 27 25 EXPOSED STEEL 1,2 4 NON DUCTED UNIT:PROVIDE CONDENSATE DRAIN PUMP(I.E.GOBI 230-XL-2.5 GPH @ 10 FT LIFT&<100 FT HORIZ,115V/1 PH @ 32W,5 LBS).TERMINATE CONDENSATE DRAIN PIPING INTO NEAREST RD5 TITUSTMRA ROUND CEILING 14" 660 28 31112 23 EXPOSED STEEL 1,2 HUBIFLOOR DRAIN;CONDENSATE DRAIN PIPING BY PLUMBING CONTRACTOR City of Arlington RD6 TIT 8 USTMRA ROUND CEILING i6" 60 32 36 24 EXPOSED STEEL 1,2 5 DUCTED UNIT:PROVIDE PLENUM RATED CONDENSATE PUMP(I.E.LITTLE GIANT MODEL VCC-20-P,55 GPH AT 4 FT LIFT-1/30HP @ 11 5V11 PH)ROUTED TO NEAREST INDIRECT DRAIN LOCATION; BUIICIIn Department RN TFUSTM A, ROUND CEILING 18" 1080 36 40112 24 EXPOSED STEEL 1,2 CONDENSATE DRAIN PIPING BY PLUMBING CONTRACTOR.PROVIDE FIELD FABRICATED MIXING BOX WITH 2"FILTER RACK AND FILTER ACCESS DOOR.PROVIDE PLENUM RATED OVERFLOW SHUT-OFF g p RD8 TITUSTMRA ROUND CEILING 20" 1340 40 45112 25 EXPOSED STEEL 1,2 DEVICE CONFORMING TO ILL (I.E.RECTORSEAL SS2AP)IN LIEU OF SECONDARY DRAIN PAN APPROVED RD9 TITUSTMRA ROUND CEILING 24" 1890 1 48 1 541/2 25 EXPOSED STEEL 1,2 6 OUTSIDE AIR INDICATES MINIMUM CFM PER ASHRAE.TAB WORK MUST MEET OR EXCEED INDICATED QUANTITY. GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS 7 ECONOMIZER EXEMPT PER 2021 WSEC C403.5 EXCEPTION I B DOAS ERV Kevin Olander- 11/18/2025 PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL PER MANUFACTURERS REQUIREMENTS 8 ECONOMIZER EXEMPT PER 2021 WSEC C403.5 EXCEPTION 9 ELECTRONIC EQUIPMENT ROOM 9 PROVIDE FILTERS AT RETURN AIR OPENINGS OF NEW AND/OR EXISTING UNITS,UPSTREAM OF ANY HEAT EXCHANGER OR COILS PER WSMC605 No changes authorized unless approved by 1 RUNOUTSIZESAMESIZE DIFFUSERNECKSIZE,U.N.O. DWGS. 10 PROVIDE SEISMIC BRACING PER ACSE 7,UNLESS:UNIT IS WALL MOUNTED OR<20 LBS OR IS RIGID MOUNTED INLINE WITH DUCT(NO FLEX)AND<75 LBS the Building Official 2 BLACK COLOR,CONFIRM WITH ARCHITECT PRIOR TO ORDERR 11 PROVIDE WITH AIREX PROSYSTEM KIT E-FLEX GUARD OR APPROVED EQUAL WHEN EXPOSED TO WEATHER IN COLOR TO MATCH SURROUNDING AREAS(BLACK OR WHITE)COLOR FROM EXTERIOR PENETRATION TO CONDENSING UNIT CONNECTION IN COMPLIANCE WITH(WSECISEC)C403.2.9.1 MODULAR DIFFUSER SCHEDULE 06 24 25 MECHANICAL 30%DO SET UNIT TAG MANUFACTURE CFM N INCHES SIZE FACE SIZE MOUNTING SOUND NC MATERIAL NOTES MECHANICAL 65% SET OUTDOOR UNIT HEAT PUMP SCHEDULE 1D 23 25 MECHANICAL PERMIT ser DT1 TINS MCD 110 6 6X6 24X24 T-BAR <10 STEEL 1,2,3,4,5 COOLING HEATING CONNSIZE EFFICIENCIES ELECTRICAL DT2 TINS MCD 230 8 8X8 24X24 T-BAR 17 STEEL 1,2,3,4,5 UNIT MANUFACTURE CAPACITY CAPACITY REFRGNT SUCTION LIQUID SOUND WEIGHT DT3 TITUS MCD 350 10 1OX10 24X24 T-BAR 17 STEEL 1,2,3,4,5 TAG LOCATION SERVES &MODEL BTUH BTUH TYPE IN IN SEER2 HSPF2 MCA MCOP VIPH dBA LBS NOTES MARK DATE DESCRIPTION DT4 TITUS MCD 500 12 12 X 12 24 X 24 T-BAR 20 STEEL 1,2,3,4,5 ODU-101 CONCRETE PAD OFFICE GOODMAN GZV6SA-181 OA 23200 23200 R-32 3/4 318 19 8.8 16.8 20 208/1 55 122 1,2,3,4,5,6,7 DT5 TINS MCD 600 12 14 X 14 24 X24 T-BAR 20 STEEL 1,2,3,4,5 ODU-102 CONCRETE PAD AV EQUIP DAIKIN RXM30WVJU9 31400 R-41 OA 5/8 1/4 17.5 7.5 18.6 20 208/1 56 133 1,2,4,5,6,7,8 PROJECT N0: 2025-021 DT6 TINS MCD 880 14 16 X 16 24 X24 T-BAR 26 STEEL 1,2,3,4,5 CAD DWG FILE: M002.DWG DT7 TINS MCD 1120 16 18 X 18 24 X24 T-BAR 20 STEEL 1,2,3,4,5 GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION& DRAWN BY: OWN A INSTALL PER MANUFACTURERS REQUIREMENTS A CHK'D BY: DWN GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS 1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTECTION DIRECTION FOR EQUIPMENT AS REQUIRED BY LATEST APPROVED VERISON OF THE NATIONAL ELECTRICAL CODE,PRIOR TO ORDER. PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL PER MANUFACTURERS REQUIREMENTS MANUFACTURER TO PROVIDE SCCR LISTING(5 KAIC MINIMUM OR PER ELECTRICAL CONTRACTOR CALCULATION)INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. COPYRIGHT: 1 RUN OUT SIZE SAME SIZEAS DIFFUSER NECKSIZE,U.N.O.ON DWGS. 2 DISCONNECT SWITCH MAY BE REQUIRED FOR EACH MODULE ON MULTI MODULE UNITS(ELECTRICAL CONTRACTOR TO VERIFY WITH JURISDICTION HAVING AUTHORITY) 2 ALL DIFFUSERS TO HAVE SIDE INLET SHEET METAL CAN PLENUM IF<1 DR STRAIGHT FLEX AVAILABLE FOR TOP INLET 3 R-32 REFRIGERANT,MAXIMUM TOTAL SYSTEM REFRIGERANT LINE LENGTH AND MAXIMUM LIFT TO BE VERIFIED WITH MANUFACTURER-VERIFY ACCEPTABLE REFRIGERANT LINE SIZING, SHEET TITLE 3 PROVIDE PERFORATED INTERIOR PLATE ON DIFFUSER CAN AND I"SOUNDLININGIFSPACE<-NC-30OR SAT<55°F LENGTHS AND LIFTS WITH MANUFACTURER PROVIDED SIZING PROGRAM SCHEDULES SHEET 4 STANDARD WHITE POWDER COAT 4 PRESSURE TEST REFRIGERANT PIPING AT 600 PSI 5 PROVIDE FRAME 3,LAY-IN TYPE. 5 TERMINATE CONDENSATE DRAIN PIPING INTO BUILDING ROOF DRAINS.CONDENSATE DRAIN PIPING BY PLUMBING CONTRACTOR 6 PROVIDE SURFACE MOUNTING FRAME MODEL TRM-S FOR GRILLE REMOVAL&INSTALLATION IN HARD LID CEILING 6 UNIT TO BE CON FIGURED TO PROVIDE LOW AMBIENT COOLING AT BELOW 24°F&HEATING AT BELOW 24°F 7 WHERE VOLUME DAMPERS ARE NOT ACCESSIBLE,PROVIDE HAND HOLE ACCESS OR YOUNGS REGULATOR WITH CEILING PLATE 7 PROVIDE WITH AIREX PROSYSTEM KIT E-FLEX GUARD OR APPROVED EQUAL WHEN EXPOSED TO WEATHER IN COLOR TO MATCH SURROUNDING AREAS(BLACK OR WHITE)COLOR FROM EXTERIOR OR DURODYNE CABLE OPERATED DAMPERWTH CABLE ROUTED INSIDE DUCT&ADJUSTMENT THROUGH GRILLE FACE 8 REFRIGERANT: R-410A. PROVIDE ADDITIONAL CHARGING OF LINES AS REQUIRED FOR LONG LINE LENGTH APPLICATIONS 1 2 3 4 5 M002 SHEET OF 1 2 3 4 5 G AQUA AIR NEW GAS FURNACE SCHEDULE UNIT AREA BASIS OF COOLING HEATING OSA ESP INDOOR FAN GAS HEAT MBH ELECTRICAL WEIGHT AQUA AIR ENGINEERING DEMO EXIST GAS FURNACE SCHEDULE TAG LOCATION SERVED DESIGN CFM CFM CFM IN WG HP RPM CONTROL INPUT OUTPUT AFLUE MCA MOCP V/PH LBS REMARKS 12400 SE 38TH ST #50014 UNIT AREA BASIS OF SUPPLY GAS HEAT MBH AH-M101 MEZZANINE SANCTUARY WING GOODMAN GRVT960804CNA 1,300 1,300 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 11511 137 1,2,3,4,5,6,7,8 TAG LOCATION SERVED DESIGN CFM INPUT OUTPUT REMARKS AH-M102 MEZZANINE SANCTUARY WING GOODMAN GRVT960804CNA 1,300 1,300 791 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 11511 137 1,2,3,4,5,6,7,8 BELLEVUE, WA 98015 F-1 MECHRM SANCTUARY RHEEM 40 1 AH-M103 MEZZANINE SANCTUARY S CENTER GOODMAN GRVT960804CNA 1,260 1,260 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 11511 137 1,2,3,4,5,6,7,8 www.Ogu001Tengineering.com F-2 MECHRM SANCTUARY RHEEM 20 1 AH-M104 MEZZANINE SANCTUARY S CENTER GOODMAN GRVT960804CNA 1,260 1,260 1,014 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 11511 137 1,2,3,4,5,6,7,8 UBI: 605247933 AH-M105 MEZZANINE SANCTUARY S CENTER GOODMAN GRVT960804CNA 1,260 1,260 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 11511 137 1,2,3,4,5,6,7,8 D REMARKS: AH-M106 MEZZANINE SANCTUARY N CENTER GOODMAN GRVT960804CNA 1,260 1,260 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 11511 137 1,2,3,4,5,6,7,8 D 1 DEMO EXISTING FURNACE AH-M107 MEZZANINE SANCTUARY N CENTER GOODMAN GRVT960804CNA 1,260 1,260 1,014 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 11511 137 1,2,3,4,5,6,7,8 CONSULTANTS AH-M108 MEZZANINE SANCTUARY N CENTER GOODMAN GRVT960804CNA 1,260 1,260 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 11511 137 1,2,3,4,5,6,7,8 AH-M109 MEZZANINE SANCTUARY WING GOODMAN GRVT960804CNA 1,300 1,300 1 710 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 11511 137 1,2,3,4,5,6,7,8 AH-M110 MEZZANINE SANCTUARYN WING GOODMAN GRVT960804CNA 1,300 1,300 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 115/1 137 1,2,3,4,5,6,7,8 AH-M111 MEZZANINE FOYER GOODMAN GRVT960804CNA 1,093 1,093 513 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 115/1 137 1 1,2,3,4,5,6,7,8 AH-M112 MEZZANINE FOYER GOODMAN GRVT960804CNA 1,093 1,093 513 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 11511 137 1 1,2,3,4,5,6,7,8 GENERAL: ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION& INSTALL PER MANUFACTURERS REQUIREMENTS REMARKS: 1 DISCONNECT AS REQUIRED BY ELECTRICAL CONTRACTOR 2 PROVIDE 1"DISPOSABLE FILTERS 3 VERTICAL AIRFLOW CONFIGURATION WITH TOP DISCHARGE 4 AIR SIDE ECONOMIZER CYCLE NOT PROVIDED-PER 2021 WSEC C403.5 EXCEPTION 1A DOAS ERV PROVISION 5 OUTSIDE AIR PROVIDED BY DOAS ERV UNITS.OSA CFM HONED IN BY CALIBRATED BALANCING DAMPER 6 PROVIDE SEVEN DAY PROGRAMMABLE STAND-ALONE THERMOSTAT WITH MICROPROCESSOR CONTROLS PER WSEC C403.4.1 ���LIAtijN 7 HEATING&COOLING FANSIPUMPS SHALL SHUT OFF WHEN THERE IS NO CALL FOR HEATING AND COOLING IN THE ZONE PER WSEC 2021 C403.3.5.2,EXCEPT IF HEATING/COOLING FANS<0.12WICFM Q of wnsyti O,p 8 SMOKE DETECTORS(PROVIDED AND INSTALLED BY ELECTRICAL)IN RETURN AIR UNLESS SINGLE SPACE OR AREA DETECTION SHUTOFF THRU FIRE ALARM OR MUA IF ALL AIR IS EXHAUSTED w �E53350GIs e TRANSFER/ RETURN / EXHAUST AIR GRILLE SCHEDULE SPLIT SYSTEM OUTDOOR CONDENSING UNIT SCHEDULE �SS7�NA�E�G UNIT MANUFACTURE MAX NECK SIZE FACE CONN SIZE EFFICIENCIES ELECTRICAL iolaslas TAG &MODEL CFM INCHES SIZE MOUNTING MATERIAL NC NOTES UNIT MANUFACTURE ASSOCIATED COOLING CAPACITY MBH REFRGNT SUCTION LIQUID SOUND WEIGHT EC1 TITUS50E-7 500 ---- 24x12 T-BAR STEEL 2,9,10 TAG LOCATION SERVES &MODEL COOLING COIL TOTAL SENSIBLE TYPE IN IN EER2/SEER2 HSPF MCA MCOP VIPH dBA LBS NOTES EC2 TITUS50E-7 1000 ---- 24x24 T-BAR STEEL 2,9,10 PHASE 2 ROCKCREEK CHURCH ARLINGTON EC3 TITUS 7 2000 24x48 T-BAR STEEL 2 g 10 S50E- ---- CU-101 OUTSIDE SANCTUARY WING GOODMAN GXV6SS4810A DX-M101 45500 34125 R-32 718 1/4 8.6/16.0 NIA 31.8 35 208/1 72 169 1,2,3,5,6,7,8,9,10,11C C TITUS3S5OF -15 150 8 8x8 GWB STEEL 1,3,6,7/8,9,10 CU-102 OUTSIDE SANCTUARY WING GOODMAN GXV6SS481 CA DX-M102 45500 34125 R-32 7/8 1/4 8.6/16.0 N/A 31.8 35 208/1 72 169 1,2,3,4,6,7,8,9,10,11 C 730 E HIGHLAND DRIVE G2 TITUS 35ORL AG-1 5 250 10 10x10 GWB STEEL 1,3,6,7/8,9,10 CU-103 OUTSIDE SANCTUARY S CENTER GOODMAN GXV6SS481 CA DX-M103 45500 34125 R-32 7/8 1/4 8.6/16.0 NIA 31.8 35 208/1 72 169 1,2,3,4,6,7,8,9,10,11 ARLINGTON, WA 98223 G3 TITUS 35ORL AG-1 5 375 12 12x12 GWB STEEL 1,3,6,7/8,9,10 CU-104 OUTSIDE SANCTUARY S CENTER GOODMAN GXV6SS481 CA DX-M104 45500 34125 R-32 7/8 1/4 8.6/16.0 NIA 31.8 35 208/1 72 169 1,2,3,5,6,7,8,9,10,11 MECHANICAL DRAWINGS G4 TITUS 35ORL AG-15 525 14 14 x 14 GWB STEEL 1,3,6,7/8,9,10 CU-105 OUTSIDE SANCTUARY S CENTER GOODMAN GXV6SS481 CA DX-M105 45500 34125 R-32 7/8 1/4 8.6/16.0 NIA 31.8 35 208/1 72 169 1,2,3,5,6,7,8,9,10,11 GS CU-106 OUTSIDE SANCTUARY N CENTER GOODMAN GXV6SS481 OA DX-M106 45500 34125 R-32 7/8 1/4 8.6/16.0 NIA 31.8 35 208/1 72 169 1,2,3,5,6,7,8,9,10,11 OWNER TITUS 35ORL 00 14 16 GWB STEEL 1,3,6,7/8,9,10 G6 TITUS 35ORL AG-15 900 16 18 8X x 18 GWB STEEL 1,3,6,7/8,9,10 CU-107 OUTSIDE SANCTUARY N CENTER GOODMAN GXV6SS4810A DX-M107 45500 34125 R-32 718 1/4 8.6/16.0 NIA 31.8 35 208/1 72 169 1,2,3,5,6,7,8,9,1 Q11 MARYSVILLE FREE METHODIST CHURCH ER G7 TITUS 35ORL AG-1 5 1200 16 24x24 GWB STEEL 1,3,6,7/8,9,10 CU-108 OUTSIDE SANCTUARY NCENT GOODMAN GXV6SS481 CA DX-M108 45500 34125 R-32 7/8 1/4 8.6/16.0 N/A 31.8 35 208/1 72 169 1,2,3,4,6,7,8,9,10,11 6715 GROVE ST, G8 TITUS 35ORL AG-15 2400 20 24x48 GWB STEEL 1,3,6,7/8,9,10 CU-109 OUTSIDE SANCTUARY WING GOODMAN GXV6SS481 OA DX-M109 45500 34125 R-32 7/8 1/4 8.6/16.0 NIA 31.8 35 208/1 72 169 1,2,3,5,6,7,8,9,10,11 MARYSVILLE, WA 98270 T1 TITUS 35ORL 150 ---- 8x8 GWB STEEL 3,9,10 CU-110 OUTSIDE SANCTUARY WING GOODMAN GXV6SS481 CA DX-M110 45500 34125 R-32 7/8 1/4 8.6/16.0 NIA 31.8 35 208/1 72 169 1,2,3,4,6,7,8,9,10,11 T2 TITUS 35ORL 250 ---- 10x10 GWB STEEL 3,9,10 CU-111 OUTSIDE FOYER GOODMAN GXV6SS481 DX-M111 45500 34125 R-32 7/8 1/4 8.6/16.0 NIA 31.8 35 208/1 72 169 1,2,3,5,6,7,8,9,10,11 T3 TITUS 35ORL 375 ---- 12x12 GWB STEEL 3,9,10 CU-112 OUTSIDE FOYER GOODMAN GXV6SS481 CA DX-M112 45500 34125 R-32 7/8 1/4 8.6/16.0 NIA 31.8 35 208/1 72 169 1,2,3,5,6,7,8,9,10 11 MECHANICAL CONTRACTOR T4 TITUS 35ORL 525 ---- 14x14 GWB STEEL 3,9,10 T5 TITUS 35ORL 600 ---- 16 x 16 GWB STEEL 3,9,10 GENERAL ALL TRADESTO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIORTO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL T6 TITUS 35ORL 900 ---- 18x18 GWB STEEL 3,9,10 PER MANUFACTURERS REQUIREMENTS ^y U T7 TITUS 35ORL 1200 ---- 24x24 GWB STEEL 3,9,10 1 ELECTRICAL CONTRACTORTO PROVIDE SCCR PROTECTION DIRECTION FOR EQUIPMENTAS REQUIRED BY LATEST APPROVED VERISON OF THE NATIONAL ELECTRICAL CODE,PRIORTO ORDER. T8 TITUS 35ORL 2400 ---- 24 x 48 GWB STEEL 3,9,10 MANUFACTURER TO PROVIDE SCCR LISTING(5 KAIC MINIMUM OR PER ELECTRICAL CONTRACTOR CALCULATION)INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. 2 SPLIT SYSTEM UNITS REQUIRE DISCONNECT AT THE CONDENSING UNIT BY ELECTRICAL CONTRACTOR ^y GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS 3 INVERTER DRIVEN COMPRESSOR,TEST CONDITIONS BASED ON AHRI210/240 PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL PER MANUFACTURERS REQUIREMENTS 4 REFRIGERANT:R-32.UNIT HOLDS 83 OZ.PROVIDE ADDITIONAL CHARGING OF LINES AS REQUIRED FOR LONG LINE LENGTH APPLICATIONS 1 RUNOUT SAMEAS DWG NECK SIZE U.N.O.ON DWG 5 REFRIGERANT:R-32.UNIT HOLDS 100 OZ.PROVIDE ADDITIONAL CHARGING OF LINES AS REQUIRED FOR LONG LINE LENGTH APPLICATIONS 2 CORE ONLY-LAY-IN 6 SINGLE CONDENSING UNIT FOR EACH INDOOR COOLING COIL.REFER TO MFG'S REQUIREMENTS FOR REFRIGERANT PIPE SIZES FOR EACH UNIT CONNECTION-CONFIRM CONTROL WIRE 3 SURFACE MOUNT FRAME GAUGE(14 OR 16 AWG)WITH SUBMITTALS PRIOR TO INSTALLATION TO INDOOR UNIT ^ , 4 CHANNEL FRAME-LAY-IN 7 PROVIDE WITH WIND BAFFLE AND LOW AMBIENT OR HEAD PRESSURE CONTROL SUITABLE FOR LOW AMBIENT COOLING V 5 T-BAR LAY-IN 8 ECONOMIZER EXEMPT PER 2021 WSEC C403.5 EXCEPTION 1A DOAS ERV PROVISION 6 PROVIDE OPPOSED BLADE DAMPER(OBD) 9 PROVIDE VARIABLE SPEED FAN CONTROL FOR SUPPLY FANS>5 TONS(<66%OF DESIGN SPEED AT LOW SPEED SETTING MAXIMUM)PER ENERGY CODE C403.2.11.5 7 PROVIDE DUCTBOARD PLENUM CONNECTION 10 UNIT TO BE CONFIGURED TO PROVIDE LOW AMBIENT COOLING AT BELOW 24'F/HEATING AT BELOW 24°F 8 PROVIDE SHEETMETAL PLENUM/CONNECTION 11 PROVIDE WITH AIREX PROSYSTEM KIT E-FLEX GUARD OR APPROVED EQUAL WHEN EXPOSED TO WEATHER IN COLOR TO MATCH SURROUNDING AREAS(BLACK OR WHITE)COLOR FROM EXTERIOR 9 STANDARD#26 WHITE FINISH PENETRATION TO CONDENSING UNIT CONNECTION IN COMPLIANCE WITH WSEC C403.2.9.1 B 0 10 WHERE VOLUME DAMPERS ARE NOT ACCESSIBLE,PROVIDE HAND HOLE ACCESS OR YOUNGS REGULATORWITH CEILING PLATE OR DURODYNE CABLE OPERATED DAMPER WITH CABLE ROUTED INSIDE DUCT&ADJUSTMENT THROUGH GRILLE FACE �1 DUCT DX COOLING COIL SCHEDULE UNIT BASIS ASSOCIATED FCOND CALIBRATED AIR DAMPER SCHEDULE TAG LOCATION SERVES DESIGNF CONDENSING UNIT SYSTEM CFM TMBH MBH IN WG SUCTSENS ESPIG CO L Q DRAIN TYPE IN BST REMARKS UNIT MANUFACTURE MIN ALLOWED PRESSURE DX-M101 MEZZANINE SANCTUARYSWING GOODMAN CHPEA4830C3A CU-101 AH-M101 1,300 45.5 34.1 0.4" 7/8" 1/4" 3/4" HORIZ 78 1,2,3,4,5 O TAG &MODEL LOCATION SERVES SIZE CFM MAXCFM RANGE NOTES DX-M102 MEZZANINE SANCTUARYSWING GOODMAN CHPEA4830C3A CU-102 AH-M102 1,300 45.5 34.1 0.4" 7/8" 1/4" 3/4" HORIZ 78 1,2,3,4,5 CBD1 TROXVFL DUCTWORK OSA/EXH 4" 11 54 0.12"-1.2" 1 DX-M103 MEZZANINE SANCTUARY S CENTER GOODMAN CHPEA4830C3A CU-103 AH-M103 1,300 45.5 34.1 0.4" 7/8" 1/4" 3/4" HORIZ 78 1,2,3,4,5 CBD2 TROXVFL DUCTWORK OSA/EXH 5" 23 89 0.12"-1.2" 2 DX-M104 MEZZANINE SANCTUARY S CENTER GOODMAN CHPEA4830C3A CU-104 AH-M104 1,300 45.5 34.1 0.4" 7/8" 1AH 3/4" HORIZ 78 1,2,3,4,5 CBD3 TROXVFL DUCTWORK OSA/EXH 6" 30 120 0.12"-1.2" 3 DX-M105 MEZZANINE SANCTUARY S CENTER GOODMAN CHPEA4830C3A CU-105 AH-M105 1,300 45.5 34.1 0.4" 7/8" 1/4" 3/4" HORIZ 78 1,2,3,4,5 CBD4 TROXVFL DUCTWORK OSA/EXH 8" 55 257 0.12"-1.2" 4 DX-M106 MEZZANINE SANCTUARY N CENTER GOODMAN CHPEA4830C3A CU-106 AH-M106 1,300 45.5 34.1 0.4" 7/8" 1/4" 314" HORIZ 78 1,2,3,4,5 CBD5 TROXVFL DUCTWORK OSAIEXH 10" 93 372 0.12%1.2" 5 DX-M107 MEZZANINE SANCTUARY N CENTER GOODMAN CHPEA4830C3A CU-107 AH-M107 1,300 45.5 34.1 0.4" 7B" 1AH 3/4" HORIZ 78 1,2,3,4,5 DX-M108 MEZZANINE SANCTUARY SCENTER GOODMAN CHPEA4830C3A CU-108 AH-M108 1,300 45.5 34.1 0.4" 7/8" 1/4" 3/4" HORIZ 78 1,2,3,4,5 GENERAL: WHERECFM'SSHOWNONDRAWINGSDONOTMATCHAVAILABLECFM'SLISTED,INCREASETOTHENEXTHIGHERCFM DX-M109 MEZZANINE SANCTUARYN WING GOODMANCHPEA4830C3A CU-109 AH-M109 1,300 45.5 34.1 0.4" 7/8" 1/4" 3/4" HORIZ 78 1 AVAILABLE CFM VALUES ARE:11,14,19,23,28,34,42,47,54 CFM DX-M110 MEZZANINE SANCTUARY WING GOODMAN CHPEA4830C3A CU-110 AH-M110 1,300 45.5 34.1 0.4" 7/8" 1/4" 3/4" HORIZ 78 1,2,3,4,5 2 AVAILABLE CFM VALUES ARE:23,28,34,40,48,58,67,77,89CFM DX-M111 MEZZANINE FOYER GOODMAN CHPEA4830C3A CU-111 AH-M111 1,300 45.5 34.1 0.4" 7/8" 1/4" 3/4" HORIZ 78 1,2,3,4,5 3 AVAILABLE CFM VALUES ARE:30,50,60,70,83,95,110,120 CFM DX-M112 MEZZANINE FOYER GOODMAN CHPEA4830C3A CU-112 AH-M112 1,300 45.5 34.1 0.4" 7/8" 1/4" 3/4" HORIZ 78 1,2,3,4,5 06 24 25 MECHANICAL 30%DO SET 4 AVAILABLE CFM VALUES ARE:55,75,98,122,149,175,202,230 CFM MECHANICAL 30%DO SET 5 AVAILABLE CFM VALUES ARE:93,126,164,199,235,278,306,338,372 CFM GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION& 10 23 25 MECHANICAL PERMIT SET INSTALL PER MANUFACTURERS REQUIREMENTS 1 HOUSED COIL PACKAGE WITH INTEGRATED SLOPED CONDENSATE PAN,ROUTE CONDENSATE TO CLOSEST INDIRECT DRAIN 2 PROVIDE WITH TXV(THERMAL EXPANSION VALVE) MARK DATE DESCRIPDON LOUVER SCHEDULE 3 PROVIDE WITH DUAL CIRCUITED COIL FOR CAPACITY MODULATION PROJECT NO: 2025-021 UNIT AREA MANUFACTURE MIN FREE WIDETH HIEGHT VELOCITY 4 PROVIDE PLENUM RATED CONDENSATE PUMP(I.E.LITTLE GANT MODEL VCC-20-P),55 GPH AT4 FT.HEAD-1130HP @ 115 VOLTS ROUTED TO NEAREST INDIRECT DRAIN LOCATION M002.DWG TAG LOCATION SERVED &MODEL TYPE CFM AREA SQ-FT INCHES INCHES FPM NOTES 5 HEATING&COOLING FANS/PUMPS SHALL SHUT OFF WHEN THERE IS NO CALL FOR HEATING AND COOLING IN THE ZONE PER WSEC 2018 C403.3.5.2,EXCEPT IF HEATING/COOLING FANS<0.12W/CFM CAD DWG FILE: A L-1 1STFLR DOASEXH GREENHECKESD-435 EXHAUST 1 170 0.51 1 18 12 1 333 1,2 DRAWN BY: OWN CHK'D BY: DWN GENERAL ALLTRADESTO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITHAPPROVED SUBMITTALS COPYRIGHT: PRIORTO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL PER MANUFACTURERS REQUIREMENTS City of Arlington 1 MIN 3/16"FRAME&3"INVERTED CHEVRONSAT2"ON CENTER,WELDED CONSTRUCTION(MEETSCL CONSTRSTD#0751.00) Building Department SHEET TIRE 2 SIGHTPROOF BLADES,SCREEN BEHIND IN ROOM TO BE MCNICHOLS 360220041(0.12"MESH MIN&112"HOLE MAX)OR EQUAL g p APPROVED SCHEDULES SHEET Kevin Olander- 11/18/2025 No changes authorized unless approved by the Building Official 1 2 3 4 5 M00 SHEET OFF 1 2 3 4 5 G AQUA AIR OUTSIDE AIR CALCULATION RM NUMBER AREA PPL PPLI 1000 SF RM TYPE OSA/PPL OSA/SF LAT>85°F TOTAL OSA CFM EXH/SF TOTAL EXHAUST CFM EQUIPMENT SERVING OSA CFM PROVIDED AQUA AIR ENGINEERING Platform 115 588 41 70 Theaters Stages,studios 10 0.06 No 446.9 0 0.0 12400 SE 38TH ST #50014 Sanctuary 4180 502 120 Public Spaces Places of Religious Worship 5 0.06 No 2758.8 0 0.0 BELLEVUE, WA 98015 Green Room 116 256 8 30 Hotels,motels,resorts Lobbieslpretuncton 7.5 0.06 NO 73.0 0 0.0 Green Room114 371 11 30 Hotels,motels,resorts Lobbies/pretuncton 7.5 0.06 No 105.7 0 0.0 WWW.aquaairenglfleering.com Corridor Sanctuary 262 0 0 General Corridors 0 0.06 No 15.7 0 0.0 DOAS-M1,DOAS-M2 3529 UBI: 605247933 Tech 103 142 1 5 Office Space 5 0.06 No 12.1 0 0.0 D Tech 104 106 1 5 Ofice Space 5 0.06 No 9.0 0 0.0 D Family 112B 102 5 50 General Conferencelmeeting 5 0.06 No 31.6 0 0.0 CONSULTANTS Family 112A 187 9 50 General Conference/meeting 5 0.06 No 58.0 0 0.0 Hallway 102 872 0 0 General Corridors 0 0.06 No 52.3 0 0.0 Foyer 101 2549 76 30 Hotels,motels,resorts Lobbieslprefuncton 7.5 0.06 No 726.5 0 0.0 DOAS-M1,DOAS-M2 1026 Entry 100 654 20 30 Hotels,motels,resorts Lobbieslpretuncton 7.5 0.06 No 186.4 0 0.0 Church Office 664 3 5 1 Ofice Space 5 0.06 No 56.4 0 0.0 1 ERV-1 170 REFRIGERANT VOLUME ANALYSIS PROJECT: ARLINGTON ROCK CREEK CHURCH DATE: 10/21/2025 SYSTEM& SYSTEM COMMON SPACE VOLUMES ACTUAL MAX CODE ADJ MAX COMPLIES ROOM REFRIG CAP AREA CEILING VOLUME LBSPER REFRIG LBS PER CODE LBS WITH SAFETY NAMES (LBS) (SF) (FT) (CF) 1000 CF TYPE 1000 CF PER 1000 CF CODE? FACTOR �APPROACHTO COMPLIANCE(IF REQUIRED) ��VLIAM N CU-101 1 99.0 4,180 25.0 104,500 0.9 R-32 4.8 4.8 YES 507% Q Of WAsy��t7P THROUGH SANCTUARY113 4,180 25.0 104,500 Q ti TO w CU-112 0 CU-101 1 99.0 480 9.0 4,320 22.9 R-32 4.8 4.8 NO 21% OK-WITH ADJACENT CONNECTED VOLUME THROUGH 1OX10TRANSFFR GRILLESABOVE 53350 to THROUGH LAUNDRY 110 480 9.0 4,320 TO CONNECTWITH SANCTUARY 0 STER�� CU-112 HALLWAY 108 0 �ss/ONM-��G 0 0 012SIAs CU-111& 1 16.5 4,075 10.0 40,750 0.4 R-32 4.8 4.8 YES 1185% PHASE 2 ROCKCREEK CHURCH ARLNGTON CU-112 FOYER 101 4,075 10.0 40,750 CU SYSTEM 99.0 289 9.0 2,601 38.1 R-32 4.8 4.8 NO 13% OK-WITH ADJACENT CONNECTED VOLUME THROUGH 1OX10 TRANSFER GRILLES ABOVE 730 E HIGHLAND DRIVEARLNGTO N, WA 98223 FAMILY VIEWING 289 9.0 2,601 TO CONNECTWITH FOYER 0 MECHANICAL DRAWINGS CU SYSTEM 1 99.0 4,409 10.0 44,090 2.2 R-32 4.8 4.8 YES 214% OWNER FAMILY VIEWING 334 10.0 3,340 MARYSVILLE FREE METHODIST CHURCH FOYER 4,075 10.0 40,750 6715 GROVE ST, o MARYSVILLE, WA 98270 CU SYSTEM 99.0 248 9.0 2,232 44.4 R-32 4.8 4.8 NO 11% OK-WITH ADJACENT CONNECTED VOLUME THROUGH 1OX10 TRANSFER GRILLES ABOVE TECH AREA 248 9.0 2,232 TO CONNECTWITH SANCTUARY MECHANICAL CONTRACTOR 0 CU SYSTEM 99.0 4,428 24.2 106,980 0.9 R-32 4.8 4.8 YES 519% ^y TECH AREA 248 10.0 2,480 SANCTUARY113 4,180 25.0 104,500 0 •^y ODU-101 6.1 1,406 12.2 17,106 0.4 R-32 4.8 4.8 YES 1341% OK-WITH ADJACENT CONNECTED VOLUME THROUGH 1OX10 TRANSFER GRILLES ABOVE OPEN OFFICE 123 418 9.0 3,762 TO CONNECTALLTHE OFFICE AREAS OFFICE 124 71 9.0 639 OFFICE 125 87 9.0 783 OFFICE 126 88 9.0 792 ^ , 0 ODU-102 1 5.0 371 15.0 5,565 0.9 R-410s 26.0 26.0 YES 2894% GREEN ROOM 114 371 15.0 5,565 0 B NOTES: B MIN SMALLEST COMMON ROOM VOLUMETO MEET REFRIGERANT VOLUME LIMITS OF THE IMC,PER ASHRAE STANDARD 15-34 COMMON DUCTS OR FIXED PERMANENT OPENINGS BETWEEN ROOMS(TRANSFER GRILLES)ALLOWS COMBINATION OF AJACENT ROOM VOLUMES (�1 O FAN SCHEDULE UNIT MANUFACTURE ARRANGEMENT ESP FAN ELECTRICAL SOUND WEIGHT TAG LOCATION SERVES &MODEL TYPE MOUNTING CFM IN WG RPM BHP HPNV V/PH DAMPER dBA LBS NOTES EF-103 JANITOR JANITOR G'HECK SQ-70 INLINE HUNG 100 1 0.2 1300 0.02 1150 1 120/1 MD 40 28 1,2,3 EF-M101 MEZZANINE RESTROOM G'HECK SQ-100-VG INLINE HUNG 750 1 0.2 1067 0.06 1/4 1 12011 - 46 55 1,2,4,5 GENERAL: ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION& INSTALL PER MANUFACTURERS REQUIREMENTS REMARKS: 1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTECTION DIRECTION FOR EQUIPMENT AS REQUIRED BY LATEST APPROVED VERISON OF THE NATIONAL ELECTRICAL CODE,PRIOR TO ORDER. 06 24 25 MECHANICAL 30%DID SET MANUFACTURER TO PROVIDE SCCR LISTING(5 KAIC MINIMUM OR PER ELECTRICAL CONTRACTOR CALCULATION)INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. MECHANICAL 65%DID SET 2 ELECTRICAL DISCONNECTAND MOTOR STARTER(AS REQUIRED)BYELECTRICAL CONTRACTOR 10 23 25 MECHANICAL PERMIT SET 3 FAN TO OPERATE CONTINUOUSLY 4 FAN TO OPERATE DURING BUILDING OCCUPIED HOURS THROUGH BUILDING EMS BY CONTROLS CONTRACTOR 5 MOTOR TO BE ECM(OR 70%MINIMUM EFFICIENCY)PER ENERGY CODE C405.8 FOR MOTORS GREATER OR EQUAL TO 1/12 HP&LESS THAN 1 HP MARK DATE DESCRIPRON PROJECT NO: 2025-021 CAD DWG FILE: M002.DWG DRAWN BY: OWN A City of Arlington A CHK'D BY: DWN Building Department COPYRIGHT: APPROVED SHEET TIRE Kevin Olander- 11/18/2025 SCHEDULES AND No changes authorized unless approved by CALCULATIONS SHEET the Building Official 1 2 3 4 M004 5 SHEET OF 1 2 3 4 5 G AQUA AIR I . I AQUA AIR ENGINEERING 12400 SE 38TH ST #50014 I BELLEVUE, WA 98015 www.aquaairergineering.com J ---------------------II-------- -- ----- — — — ,I UBI: 605247933 I i -1R I I,I I D rrrr III ID _J1 CONRCTANIS J III loll- I lollIII \' & & rr`-==-==----- ---- --- -------------71 JI I III I II W , I -71 II y II II 1 ' :::W '��__�-=_�I ICI C7 C7 I II I I I I DEMO EXISTING MECHANICAL FLOOR REGISTERS / DIFFUSERS 111 IN SANCTUARY AREA rt== (TYP) ��VLIAM N O OF WASy� 0 _ II i 1�y===------------Jj r� rF II SA�ca - I 53350 ❑ ��`�.�EGISTeR��G� SS/pNA\L IL JI II Ir__________-11 ''✓ IL 1012SIA, ' -- lIL _jI� PHASE 2 ROCKCRFFK CHURCH ARLINGTON, --� -- ii -�DEMOEXISTING NATURAL GAS C 730 E HIGHLAND DRIVE II rye rr- h a"N� FURNACES F_1 ARLINGTON, WA 98223 i `i IL tJ li F_2 MECHANICAL DRAWINGS A ��r IF-------- -TI Il NG II a I1 1'NG OWNER C-J II II p� 'L__1II JI II�(�120 �'IBH� �� �� it�__� � �r-�� r� 5, -- IIIs"FLUE UP 3,4"Nc MARYSVILLE FREE METHODIST CHURCH ,.L �O MB ) 6715 GROVE ST, 3"FLU UP II it I i,' MARYSVILLE, WA 98270 2"NG AT 7"W.C.�I jlj 2"FLI,(DN _ ;I M,- TO EXISTING GAS FURNACEANDjIC, LGAS WATER LCOIRACrORlL_---_J11HEATERS7p fir____ EXIS'fR G \ rAND RELIJ F (VENT OW�� J - IIEXISTING, TURA d -0 ''ii y,rITHA ALL VV it 1/2"NG AT -- 1/2"NG AT Ir_ --{ , r JI FQUIRED.WATEE TINT -1 ICAP. j', j EXISTING GAS �// 7WC 1 I'�°all TII VENTING MAIN IT RETvfA1f0.-- III ^~ .1 tJJ 11111111111111 FURNACE _ �y ^-45 MBH Ir_ _ I�II II II o-�JJ 0 III -`II 1 IpS II 11 II (-12 II - <� I�{j� 'll II ("'120 MBH) 1/2..NG p 'I < I,(-40 MBH) 1�2NG IL___t_____i�'JI 'I IL_-_- L s -T -- _____ _______________ _______� ___ , , DEMOEXISTINGI/2"NATURALTI AT 7'W.C. IL JL II L__ �1 V L1, --�', I GAS LINE FOR UPSIZED NEW I `T--� � Ilk I I 2"NG `-' GAS LINE.FIELD VERIFY SIZE 11 L_________� II (^-190 MBH) ==fi 7"W.C. AT 7"W AT AND LOCATION PRIOR TO WORK. JJ FIELD COORDINATE IF II 7"W.C. TO I,DISH TO ___--_ — _ ___ m FIREPLACE II DISHW�,SHE "I /L� �1J EXISTING GAS L30 MBH FIREPLACE IS TO II r _a ��___� B A _ V 2"NG REMAIN OR BE DEMO'ED Y I� j ________ i (^-370 MBH) L--JI r ' I / xs xe xe xc II xs T�xc� i 2„NG \• -- xFOoER H (-140 �ABH)1" _ o (^'370 MBH) __ T1 40/MBH " - __ } DEMO EXISTING 1/2"NATURAL II I'1"NG ON!AT Ij Ilj —' Tll GAS LINE FOR UPSIZED NEW EXI$TMGWR-t ___ _ --" I I GAS LINE�FaF10 VERIE;1'SIZE II III r�� 1 AND L 6ATION PRIOR & OVEN 11W DEMO EXISTING 2'NATURAL 9 To 11 Ik ssrt� __ ______________J GAS LINE FOR UPSIZED NEW WORK DEMO EXISTING II URALGAS GAS LINE.FIELD VERIFY SIZE II I_� J -wawa' i NATFURNACE r T T -'L AND LOCATION PRIOR TO 11 ,I'I L '� -- WORK.Ell / II II IIII II l II II 1 IP I'IRI u�� l 2 NG 5 M II ------------------------------------ ❑ L IJs r�;«�f^.1 ,.•�_ BH) ❑ p ❑ 4 ❑ p ❑ (^41 p .-._._ ,,,�r� i i'i I 06 24 25 MECHANICAL 30%DID SET 65% �- �I� � 1 r- ----- ---- -L MECHANICAL PER IT SET y—=«= PII 10 23 25 MECHANICAL PERMIT SET � I I MARK DATE DESCRIPIION City Of Arlington PROJECT NO: 2025-021 11 11 1 CAD DWG FILE: w.ozm.owc s „ ❑N Building Department o -� �r1 ❑ DRAWN BY: OWN AI a APPROVED FF i illy II I'I 2"NG AT A CHK'D BY: DWN 11 I' 7"W.C. Kevin Olander- 11/18/2025 COPYRIGHT: . 11 1"NG AT " -'-H' 7"W.C. I No changes authorized unless approved by a the Building Official METER. SHEET TIRE EXISTING GAS LEVEL 1 MECHANICAL DEMO i LEVEL 1 KEY PLAN ® _ (TYP 2) I 3r'=,'_a' 1 3' 5' 10, 15' PLAN ' 1 LEVEL 1 ENLARGED MECHANICAL DEMO PLAN SCALE: $"=1' 1/81,=1._01, 2' 4' 1 2 3 4 5 MD201 SHEET OF 1 2 3 4 5 AQUA AIR j AQUA AIR ENGINEERING 12400 SE 38TH ST #50014 BELLEVUE, WA 98015 www.aquaairergineering.com GGNSCONSULTANTSUBI: 605247933 D D _ 1 I -- ---------------- -1111111111111 -------------------- �r—------� SADDLE PER 2x8 @i6"oc X.&10 C15x50V C15x50 -EC C Wx21 °— C,,x50 C15x50 at u oo ADDLE PER EX.3x DECKING EX.6x10 LV o n— Oil. 115x50 EX GL51/5x21 C15x50 C15x50 1. 6 IA44 — N Q OF WASyx�O i y C15x50 EX.GL 51/8x21 S w EX 4x10 C15x50 - T' P l o EX.6x10 53350 o HGU HANGE a n o��ss/01 Te G� /1 E C15x50 C15x50 0 GL 51Bx21 " 1011g C15x50 AC15x50 EX.6x10 ..Pb.' LK PHASE 2 ROCKCREEK CHURCH ARLINGTON 730 E HIGHLAND DRIVE _ I _ _ n ARLINGTON, WA 98223 ,� II MECHANICAL DRAWINGS EX BRG.WALL OVER Ili 212x8 � EX.WIBX70 OWNER jlll I;M€N= MARYSVILLE FREE METHODIST CHURCH 6715 GROVE ST, EX. MARYSVILLE, WA 98270 I I I I I III .III I I I I I I I I I III; ;I I MECIMNC,A CONTRACTOR EX.410 - J Isr,�I_� I •�I I I I I I V I I I I r,.. B a� I I I I I I I I I I I I I I I I I I I I I I I I I I 06_2724 25 MECHANICAL 30%DD SET MECHANICAL 65%DD SET 10 23 25 MECHANICAL PERMIT SET 0 N M L K J I H G F E D C B A MARK DATE 1 DESCRIPIION / ' `MEZZANINE LEVEL MECHANICAL DEMO HVAC PLAN PROJECT N0: 2025-021 3/32"=1'-0" CAD DWG FILE: MD202.DwG City of Arlington 1'3'5' 10' 15' 25' DRAWN BY: DWN A scALF: _, Building Department A r 4• APPROVED CHK'D BY: DWN COPYRIGHT: Kevin Olander- 11/18/2025 SHEET TITLE No changes authorized unless approved by the Building Official MEZZANINE LEVEL MECHANICAL DEMO PLAN 1 2 3 4 MD202 5 SHEET OF 1 2 3 4 5 / G AQUA AIR j ---------------- l------- ------- ------- ------- -- - ------- AQUA AIR ENGINEERING I I I I I 12400 SE 38TH ST #50014 BELLEVUE, WA 98015 - - - - - - - www.aquaairergineering.com UBI: 605247933 CONSULTAM I I I D IU-ID2 SM2-215 SM3-270I _ _ __ 120 120 - - ....... T TO _ ODU-,Dz 1112 I I I MID --r- _ — - - TO MID _ r , ------------------ f _ ---- Eli - i 120 --_ __ - i"-T- I r 16X1601IDSL IU-101 3 IDX-M - __ yI14 r"100 ' ' r.SM3 280 C2 T� 1 m - - - M10 '` Y - _ 110 �• .� �I j _� - - .,.;�, '' Y AH M 101 &. \ l < - G7-50 104 AH Mll0 & `�� �. A'� < i - __ r _ -_ _ - i ��I 7� � AH M102 ABOVE WIN ll 86 80 ___ _ _ - _ Y -i - T r - - - - _ , 53350 ( Dow w 10mW ; ---� U _ - _ - _ - - - _ i .! SS/ E� d i- 1 , - � 1 I T \� I DU-101 SM7 75 W ��� C � , - 8 ----. ` s -` roles es PROVIDER-81NSULATION '� -1 i --r--"i---I---- - -_ i= �� i, CU-106 0 0 oww 1` T __;.'-1 --I vl PHASE 2 ROCKCREEK CHURCH ARLINGTON ON EXHAUST AIR DUCT �� ( ��I ,�'��d � cu 107 730 E HIGHLAND DRIVE C PER2021 WSEC. . j ( {- - i 'y cu-,o6 C403101.2 PROVIDER-71NSU \, 8 _ --_,y- f ---i"--r-- --T "-�- -' T: 0 ON OUTSIDE AIR DUCT I ---- '------1--:----- -""1 �� C ARLINGTON, WA 98223 PER 2021 WSEC 1411 XHAUST AIR I I SM1-loo CU-103 c403.10.1.1 �` DUCT IUP To 80 ._ I7 n cu-1oa MECHANICAL DRAWINGS ATTIC F FI P- ' � L CU-105 OWNER 12 TRANSFER GRILLES LOW IN WALL6' A.F.F. FOR _ �1 INSTALL A REQUIRED SET OF TWO MINIMUM 10'X10" - ---, NEAR r �� EF-10 CU-101 MARYSVILLE FREE METHODIST CHURCH r MEZZANINE CONSTRUCTION NOTES: � - - - - ,-� , (MAX( ) -- 120 Y m cu-1oz 6715 GROVE ST, POSSIBLE REFRIGERANT LEAKAGE. a Y II TO D M106, TO DX-M103, SM3-250 •',� .W CU-,,, MARYSVILLE, WA 98270 �2 INSTALL A REQUIRED SET OF TWO 10"X10' TRANSFER , (2 12 II III_ _� &HAH106, H-M1087, DX -M103, AH-A�104,105, 100 - 120 SUPPLY AIR i� EXISTING GRILLES LOW IN WALL 6"A.F.F. FOR POSSIBLE r I LOUVER NECI4NC,A CONIRACrOR (MAX( P ' \ & AH-M105 DUCT UP TO li REFRIGERANT LEAKAGE. REFRIGERANT PIPING IS NOT TO GO 106 1 L__- THROUGH THE FAMILY VIEWING AREA. REFRIGERANT PIPING TO _ ��2 F-- ,i ATTIC NEAR BE OVER THE TABLE STORAGE AREA. 120 K III 1 MEZZANINE -----` -- �14m-� '�' SM2-170 Oj 100 EX I TINS` Too RA uP=- DR ER O3 INDOOR UNIT TO CENTERED BETWEEN JOISTS IN CEILING 10 f 1 F+ - T212 T LO ^~ U Ali SPACE OTC. ADD SOUND LINED DUCT AT RETURN OPENING 1i C. 01 100 SM3-281 ,"� __ WALL FOR ACOUSTICS. ADD BACK DRAFT DAMPER IN RETURN - -- _ DUCTWORK FOR BEST DECOUPLED OPERATION OF THE BOAS _ -- - - IZ/� - - - -I� 100 1 100 ERV UNIT. - //, •�I 12.7S PP&,,AI LJ ® TRANSFER GRILLE HIGH IN WALL FOR RETURN AIR PATHWAY _ MEZZ NINE ` •• J DU 100 TO ABOVE CEILING IN FOYER. - - - - O5 PROVIDE ACCESS PANEL FOR BOAS ERV LARGE ENOUGH FOR 1 0 12m 12 ®G1220400 lip 1 f RA UP REPLACEMENT AND SERVICE. '� 120 - - T 11�L -------y-�--- - 16 © COORDINATE T'STAT LOCATION WITH CLIENT, ARCHITECT, AND 10 T & AH M1 y'I� IATJi IZ G.C. �. .�, 18 6^ - 100 O7 RECONFIGURE DRYER EXHAUST ON THE OTHER SIDE OF WALL T2- 05 TO CONNECT TO EXISTING DRYER EXHAUST IN WALL. 80 8 0 18 B0 Q r i -- - - - - 4Z e2 Y Y TD;0330 - r- 0 T� 10 14 .. 07 6 24 25 MECHANICAL 30%DID SET �' + Y r Pry ___ --�--- MECHANICAL 66% SET E � t� 12 0 23 25 MECHANICAL PERMITIT SET 5 -, City of Arlington -; - - _TC DX . III & AH M 1z Building Department MARK DATE DEscNiPnoN = - APPROVED PROJECT NO: 2025-021 O Kevin Olander- 11/18/2025 CAD DWG FILE: M201.DWG o changes authorized unless approved by DRAWN BY: OWN the Building Official A CHK'D BY: DWN COPYRIGHT: 10 O O O SHEEP TfTLE O ��--"" LEVEL 1 MECHANICAL HVAC LEVEL, KEY PLAN 1 1'-a' 1 3' 51 LEVEL 1 ENLARGED MECHANICAL HVAC PLAN SCALE: e"_1 0' 15' 25 PLAN 1 1/8"=1'-0' 2 4 1 2 3 4 5 M201 SHEEP OF - 1 2 3 4 5 AQUA AIR AQUA AIR ENGINEERING 12400 SE 38TH ST #50014 BELLEVUE, WA 98015 � — — — — — — — www.aquaalrenglneering.com - ----- ----- UBI: 605247933 CONSULTANTS 1 , — — - - - - - - — - - w-m: — - - 3/'CONDENSATE ON TO �.—.—•� �•—•—•T• CCWTONGUE AT ROCK oou-tat i CARDEN.AVOID DISCHARGE CON PROTEC ON. VFOR SL i I : r q i. .gyp, - -- -- - y - - r r _ i .,. -_- 3/8"RL ____ - _ - - u.,r „g - f -�� a " :'. r n ,-.,�.v �. Y "'a•v - --- ---------------- - - "._ _ .( - �'�!� 'X' CCC •/ •,�� Y� �\C �, '•�� - _ - - - _ �'\,- RELOCATE EXISTING �� ® �p ,Q 53350 3/4 COND v' GAS WATER HEATERS T EGISTER� �. Av. _ _-- �� AS REQUIRED. FdS/ ' � �c' � �y -- cu-1o9 NA "'+r" �;.• RECONFIGURE 0 v v y, �" _- F EXISTING NATURAL CU-110 rolasles 1, r 1 _ - ..." I 112 GAS AND FLUE VENT CONNECTIONS. — — 0 0 > - EACH cu-106 PHASE 2 ROCKCRFFK CHURCH ARLINGTON r ` _ CH LINE SET CONSIST$OF 't (TYP 2) _ --- -- -- ----.' ONTO IECEE �T•' •�,�•. ...� .!_-_-r ?(12)RL4AND 7/8 .. CU 107 -=tt27iSRsuPTOMEZZANI Riz) y EAGHUNEser 730 E HIGHLAND DRIVE C r CONSISTS OF 1/4' - i �, _ - ___ - - A - OMEZ�iXh7NE _ `,.i � 2 CU-108 F SINK O MEZZANINE AND 7/8"RS LINES � � � CU-103 c � ARLINGTON, WA 98223 (TYP 12) cu-104 MECHANICAL DRAWINGS 771m - T - �� E4 �L 1"NG (/f NG /' CU-105 OWNER — — — — — — MARYSVIL FREEMETHODIST CHURCH b d b 12 12 I2 CU-101 cu-,o2 6715 GROVE ST, au d HII - L cu-n1 MARYSVILLE, WA 98270 -- F, F- :: : _'J - - r 3"FLUE 3"F U /2"NG AT -- `_'III Y 120_M PIPINGT NECI4NCA CONTRACTOR ' 1 LEVEL 1 KEY PLAN ® 7"W.C. To SLOPED _ 2"NG A7'�JJ.C. 1/3T=1'-O' EXISTING GAS _ -� T71 O EXISTING PER 2021 i FURNACE 9� �T� ® _ _1 WSFGC - ___ J __I� _ GAS W TER I:J: 2'NG A + + HEAERS _ ® 'V I � _ - -- ---- 1-_ •ICI 2"Nc (�60 BH) 1/2"NG it I "NG UP TO ' (-40 MBE) MEZZANINE - - - - xc - -xc - - CONSTRUCTION NOTES: - - -- - - j i A Oi INSTALL A REQUIRED SET OF TWO 10"X10"TRANSFER _ i GRILLES LOW IN WALL (MAX 6' A.F.F.) FOR POSSIBLE 1 AT 1/2"NIG AT REFRIGERANT LEAKAGE. REFRIGERANT PIPING IS NOT TO GO "W.C. TO 7"W.C� TO THROUGH THE FAMILY VIEWING AREA. REFRIGERANT PIPING To 2-1/2 NG (^• 30 M H) FREPJ.?.CE �� DISHWASHER BE OVER THE TABLE STORAGE AREA. (960 MBH '-4 2 -- (-30 MBH) ' BO RUN REFRIGERANT PIPING THROUGH EXISTING OPENING IN r � 3 WALL (OLD LOUVER). SEAL OPENING AROUND REFRIGERANT (1, 3 M H) -270 B ) PIPING PER 2021 WSEC ENVELOPE REQUIREMENTS AND BRACING FOR REFRIGERANT PIPING. 4 H) I I I I I 1 T 3" G 7"W.C. TO EXIS G RANGE (1, 75 M H)I OVEN O v v I I I I I I I I I I I SI I 06 24 25 MECHANICAL 30%DO SET MECHANICAL 65%DO SET 10 23 25 1 MECHANICAL PERMIT SET City of Arlington NARK DATE I DESCRIPTION 7"WAT Building Department � APPROVED PROJECT NO: 2025-021 r ❑ O ❑ CAD DWG FILE: M20t.DWG A - Kevin Olander- 11/18/2025 DRAWN BY: OWN CONNECT NEW 3"NG AT i \ CHK'D BY: DWN EXISTING METER.LONGEST LINE 3"NG No changes authorized unless approved by LENGTH OF 250 FT AT 7'W.C. 8 (1,275 MBE) the Building Official COPYRIGHT: COORDINATE WITH UTILITY - COMP NY AS REQUIRED. SHEEP TITLE EXISTING GAS LEVEL 1 MECHANICAL PIPING I I I I I I .METER r -- (TYP 2) 1 1' 3' 5' 10' 15' PLAN 1 LEVEL 1 ENLARGED MECHANICAL PIPING PLAN SCALE: $"=1' 1/8"=1'-0" 2, 4, 1 2 3 4 5 MP201 SHEEP OF 1 2 3 4 5 AQUA AIR AQUA AIR ENGINEERING 12400 SE 38TH ST #50014 BELLEVUE, WA 98015 - - - - - - - - - - - - - - www.aquaalrenglneering.com UBI: 605247933 D //\RD 1802� 7 SADDLE PER _ IT) CONSULTANTSS 2x8 @16"oC 200 180 180 190 14x6 C15x 15x50 ° EX.GL 518x21 C15x50 C15x50 80 SUPPLY AIR DUCT SUPPLY AIR DUCT - 200 DUCT 200 SU CT SADDLE PER N RD4-490 X. x EC IN _ 120 120 '/ \ ts0 S 10-4 0 0X10 i60 x_ x -EX. L 1 x21 CzMIn1 50 C15x50 - RD4-490 SM10-450 160 SUPPLY AIR DUCT 120 co 2DX1D 240 SUPPLY AIR DUCT 240 SUPPLY AIR DUCT �160 SUPPLY AIR DUCT RD4-490 RD4-490 ��VLIAM N 120 120 SM10-450s1I "a Q of wnsy� O 15x C x50 20X10 EX GL 5 1 x21 Q To ts0 60 _ I SM10-450 � 20X10 �� ,Q 53350 p �/ 200 SUPPLY AIR UCT 260 SUPPLY AIR DUCT 260 SUPPLY AIR DUCT 210 SUPPLY AIR DUCT "�cS,EOISTER��G� S/ONA\-E RDa-490 RD4-490 HGU HANGER OI Ig 20 10 C1 50120 1 15 0 S PDX70 D L 5 118x2l 240 SUPPLY AIR DUCT 160 C15x5 5x50 �-240 SUPPLY AIR DUCT PHASE 2 ROCKCREEK CHURCH ARLINGTON C _ s R D 60 - 0 C 730 E HIGHLAND DRIVE I I 28Te 11 SUPPLY AIR DUCT 280 SUPPLY AIR DUCT 20X7- ARLNGTON, WA 98223 QYP 7) FROMSUPPLY UCT Bos-33 m � MECHANICAL DRAWINGS I BD5-33 TO 80 IN SUPPLY PLEN 0 To 6) BD5-33 4"SOUND LI ED 28"TALL RETURN OWNER ii BD5-33 AIR BOOT E DING FACE OF CONSTRUCTION NOTES: - - - - - ____--__ - - - - - _ ___ - ___ ___ - MARYSVILLE FREE METHODIST CHURCH 1 RETURN OPENING FOR DOAS ERV TO HAVE BACK DRAFT w 120 SO PLY AIR DUCT OPENING TO BE UNDERNEA O N TO TECH AREA -DX_M107 SUPPLY AIR DO T. 6715 GRAVE ST, DAMPER. BDS 33 160 m EX.BRG. _= 240 SUPPLY AIR DUCT 2 2x8 MARYSVILLE, WA 98270 ( MOTORIZED DAMPER CONNECTED OCCUPANCY SENSOR IN _ _ aoo DX M108 ® M105 NORTH EAST SANCTUARY. -I BD5-37 DX-M103 DX-M109 14101 AH M109 AH-M106 DH-M2 DX-M104 O3 MOTORIZED DAMPER CONNECTED OCCUPANCY SENSOR IN AH_M107 AH-M103 rEDYXICAL CONIRACFOR SOUTH EAST SANCTUARY. AH-M104 4 MOTORIZED DAMPER CONNECTED OCCUPANCY SENSOR IN =______= 180 36X20 ON AH-M108 PP Y AIR DUC 16 120 SU O DX-M102 DN TO FA ILY AREA FOYER. DOAS-M1 ^� 180 SUPPLY AH M110 1 -, - 14 3 m , AH-M105 DUL TRETURN AIR DUCT FRO AH 2 L _L AH-M102 a Ill I _ FAMILY^NV AREA._ TO JOIN T 240 EF-M101 DX-M110 - 1 BD5-23 tDO •^y SUPPLY P ENUM. 4 Pna Arnu'TIC_ BD5-27 (TYP 2) 120 e PURPOSES 180 SUPPLY DO C FROM DH-M1 m AH-M101 AH TO JOIN TO 40 20 4 SUPPLY PLENUM. Dx-M11z 805-27 IF BD5-27 DX-M101 (TYP 2) - - - - - - - - B05-23 100 100 RETURN AIR B 5- FAMILY AREA. EXHAUST DUCTWORK O s0 18 O-RET.URN T PnP a nilsnCS ROOF CAP 28'X28"( -1 PURPOSES Ex AIR CHURCH ROOF 26' 2 "(R-B OUTSIDE AIR �I AusT B DU TWORK I DU TWOR AP R IMATE B T A SF R GRILL E FOF LOCATI N OF 120 SUPPLY AIF D CT EXISTING MAN RETURN AIR P TH AY F01 FIELD VERIFYE "CT D T TECH A EA F)Y R. U T T RN AIF DIMENSIONS. - - - - If A OV C 11_ NO Y Y FLEINUM RA FED �I N x 9 I I I 0 Y ..T% I I I ��'• � I I I - � •��P �w I I I :o r �'��--•mob I I I I I I I ',"� 0 06 24 25 MECHANICAL 30%DO SET •..,� '„`.ate= MECHANICAL 65%DID SET .-. 10 23 25 1 MECHANICAL PERMIT SET City of Arlington BuilIdin9 Department artment MARX DATE DEscRIPnoN I I I I I I APPROVED PROJECT NO: 2025-021 Kevin dander- 11/18/2025 CAD DWG FILE: N202.Owc No change authorized unless approved by DRAWN BY: OWN A the Building Official A CHKD BY: DWN b b b COPYRIGHT: 0 MEZZANINE LEVEL ENLARGED MECHANICAL HVAC PLAN SHEET TITLE U 18"-''a' MEZZANINE LEVEL T MEZZANINE LEVEL KEY PLAN 1/37,=1_p. 1' 3' s 10' 15' MECHANICAL HVAC PLAN SCALE: $"=1' 2' 4' 1 2 3 4 M20 5 SHEET OFF - 1 2 3 4 5 AQUA AIR AQUA AIR ENGINEERING 12400 SE 38TH ST #50014 BELLEVUE, WA 98015 - - - - - - — — — — — — — — www.aquaalrenglneering.com UBI: 605247933 D SADDLE PER D CONSULTANTS 2x8 @16"oc C15x50 C15x50 EX.GL 518x21 C15x50 AL C15x50 SADDLE PER N X. x EC IN I C15x50 C15x50 _ _ _EX L 118x2l_ _ C15x50 C15x50 � M a l a v l o l M ��VLIAM N aO F wAs O C15x50 C15x50 _ _EX L 1 x21 H�To C15x50 AL C15x50 y 53350 GISTe ass/ONAt-ECG HGUHANGER rolssles - — — — — — _------ — C15x50 C15x50 L 51 x21 FROMEACH DUCT co)LING C15xso C15xso PHASE 2 ROCKCREEK CHURCH ARLINGTON CCOIL O ITS CORRESP NDINq 8 C 730 E HIGHLAND DRIVE (TYP12) BY P.C.DRAIN R IN ARLINGTON, WA 98223 rA BY P. ROU CONDENSATE OM MECHANICAL DRAWINGS ' 2"NG COOLING COILS TO, All-__❑ AH-M108 (400 MBH) __ FLOOR DRAIN P) OWNER — — FLOOR DRAIN OR SINK — — FacHUNEs coNSls — — MARYSVILLE FREE METHODIST CHURCH A M107 1-1/4""NG BY P.C. ROUE -M106 (240 MBH) 1/4"RLAND78"RSLINES 6715 GROVE ST, CONDENSATE FROM p BRG. ALLO (12)1/4"RLD 2 2x8 MARYSVILLE, WA 98270 - - - - COOLING AI S TO DX M108 .W18 O (12)7/8"RS DJ�I FLOOR DRAIN (TYP) DX—M103 AH M109 DX—M104 MECHANICAL CONTRACTOR AH—M103 2"NG AH—M104 ❑ O1 I 6"B—IVENT (640 MBH) AH—M105 FLUE UP T ^� O (240 MNG ROOF 3EFLUE B-VENT. INSTALL �y U CONSTRUCTION NOTES: AH-M110 (240p MBH) AH-M102 PER MANUFACTURER IOM O1 INSTALL FLUE VENT PER 2021 WSFGC 504.3 WITH PROPER 2-1/2"NG�� (TYR) _ _ 6"B-VENT SLOPE PER 2021 WSFGC. 6" B-VENT UP TO ROOF. {88@ Jv18 — — — — — DX-M110 = � FLUE UP TO •^� Oj ROOF h LONDENSATE FIR DRAIN OR SINK YROUTE I�1 AH-M101 RO -------- 1 8 COOLING COILS T 1"NG DX-M111 FLOOR DRAIN (TO) DX-M112 ( 0 MBH) G DN 960GM IH) o B LO ON OF B EXI M­­ FIEL)WF E%Aa r/l DIM NSI N. YY N X a O Y ..� ... s D� �'��--•mob I I I I I I I I 06 24 25 MECHANICAL 30%DO SET MECHANCAL 65%DD SET 10 23 25 1 MECHANICAL PERMIT SET _TIT I MARK DATE DESCRIPTION PROJECT NO: 2025-021 City of Arlington CAD DWG FILE: M202.DWG Building Department DRAWN BY: OWN A APPROVED A CHK'D BY: DWN Kevin dander- 11/18/2025 C0N1GHi` No change authorized unless approved by SHEET TRLE the Building Official MEZZANINE LEVEL / ' 1 MEZZANINE LEVEL KEY PLAN ,r=,_a ® 1' 3' 5' 10' 15' 25' MECHANICAL PIPING PLAN MEZZANINE LEVEL ENLARGED MECHANICAL PIPING PLAN SCALE: $'=1' 2' 4' 1 2 3 4 5 M P202 SHEET iG OF - 1 2 3 4 5 G AQUA AIR AQUA AIR ENGINEERING 12400 SE 38TH ST #50014 BELLEVUE, WA 98015 www.aquaairengineering.com UBI: 605247933 D D CONSULTANTS \VLIAM N Q OF WASy��OP w �O R 53350 GISTe I I S/ONA\- I I I I rolssles PHASE 2 ROCKCREEK CHURCH ARLINGTON C C 730 E HIGHLAND DRIVE ARLINGTON, WA 98223 coNsrRucnoNT NTorEs: MECHANICAL DRAWINGS O1 INSTALL FLUE VENT PER 2021 WSFGC 503.6.7 FOR ROOF TERMINATIONS WITH LISTED CAP. OWNER 02 ENSURE OSA INTAKE IS MINIMUM ,o FEET AWAY FROM FLUE — — — — — — — — — — — — — MARYSVILLE FREE METHODIST CHURCH VENTS AND EXHAUST. 6715 GRAVE ST, O3 ENSURE THAT FLUE VENT EXHAUST IS MINIMUM 10 FEET MARYSVILLE, WA 98270 AWAY FROM DECORATIVE CROSS FOR FIRE PROTECTION. ' COORDINATE WITH ARCHITECT AND G.C. / / \ MECHANICAL CONTRACTOR p 1 —II 3 Ix P-4 - - / \ / \ I 1 3 — I - - - - - - •TLI \ " 1 t I 2 / - - - - - — - - - - - -I — \ - -I - - \ i- - / - - - - - - V B I ' I I I II 13 I I I I I O _ 06 24 25 MECHANICAL 30%DID SET 10 23 25 MECHANICAL P5%DID DSEET III City of Arlington Buil ing Department APPROVED NARK DATE DESCRIPTION PROJECT NO: 2025-021 Kevin Illander- 11/18/2025CAD DWG FILE: M203.DW0 No changeuthorized unless approved by DRAWN BY: OWN e Building Official CHK'D BY: DWN COPYRIGHT: 0 ROOF ENLARGED MECHANICAL HVAC PLAN SHEET TITLE /� U ''a' ROOF MECHANICAL PLAN i ROOF KEY PLAN 1 iar�=r-a' SCALE: $"=1' 2' 4' 1 2 3 4 5 M203 SHEET I' OF - 1 2 3 4 5 G AQUA AIR AQUA AIR ENGINEERING 12400 SE 38TH ST #50014 BELLEVUE, WA 98015 www.aquaairengineering.com UBI: 605247933 D D CONSUIETANTS IA44 N Q OF WASy��O,p w 53350 p =�161=311 GISTe I2_ 12 S� G� ,oJ2SJA, EXISTIN0 �X15 2 EXISTIXN PHASE 2 ROCKCREEK CHURCH ARLINGTON C �=�0�1=�II C 730 E HIGHLAND DRIVE ARLINGTON, WA 98223 EXISTING MECHANICAL DRAWINGS OWNER MARYSVILLE FREE METHODIST CHURCH 6715 GROVE ST, MARYSVILLE, WA 98270 MOUNT CONDENSING UNIT ON STRUCTURAL UNISTRUT RACK. VERIFY MANUFACTURERS MECHANICAL CONTRACTOR RECOMMENDATIONS. (TYP 12) FT FT Pm 7-1 X ISTI N6 CU-101 CU-103 CU-106 CU-109 CU-102 CU-104 CU-107 CU-110 ^ , CU-111 CU-105 EAST ELEVATION CU-10R CU-112 ^V, B ' ` VATION MECHANICAL HVAC PLAN g a� 3' 5' 0' 15' 25' All condensing units C� must be shielded SCALE: 1 1' from view s = 2 4 06_2724 25 MECHANICAL 30%DD SET MECHANICAL 65%DO SET 104 94 23 25 MECHANICAL PERMIT SET MARK DATE 1 DESCRIPTION PROJECT NO: 2025-021 CAD DWG FILE: —.DwG DRAWN BY: OWN A City of Arlington A CHK'D BY: DWN Building Department COPYRIGHT: APPROVED SHEET TITLE Kevin Olander- 11/18/2025 MECHANICAL ELEVATIONS No changes authorized unless approved by the Building Official SHEET 1 2 3 4 5 M401 SHEET 1? OF - 1 2 3 4 5 G AQUA AIR CALIBRATED BALANCING OUTSIDE AIR DUCT SIZE AS SOUND LINED(2"R-8 MIN) AQUA AIR ENGINEERING DAMPER FOR OSA BEFORE SHOWN ON DRAWINGS.NON - DUCT 2400 SE 38TH ST #500 4 ANY OTHER SUPPLYTAPS ECONOMIZERONLV &WITHIN 2'OF FAN BELLEVUE, WA 98015 DISCHARGE IF POSSIBLE VIBRATION CAULKED JOINT BETWEEN ISOLATORS CAP AND DUCT FOR WWWAgUddlrEFIgIFI22TIIlg.COTYI WEATHER TIGHT SEAL STRAPHANGERS TRAPEZE HANGERS UBI. 6055247933 DAMPER AS SHOWN ROD SIZE FOR LOAD D FLEXIBLE _ BACK DRAFT ON PLANS 1"WIDE 20 GA* LOW PRESSURE DUCT LOW PRESSURE DUCT D CONNECTION DAMPER HANGER STRAP STRAP OR ANGLE CONSULTANTS INLET BELL SHEET METAL FLASHING ------ ___ WITH WELDED CORNER BIRD SCREEN -------i SEAMS 18 60"MAX. EQUALIZING i i MIN GRID ROOFING AND ___ CURB D (BY GC) UNLESS FOOT OF 1.5XD FLASHING STRAP IS PLACED (BY GC) UNDERABOTTOM 11 ACCEPTABLE METHOD AIR HANDLING UNIT OR FILTER � REINFORCEMENT. J� FAN COIL UNIT SECTION ' CEILING i��MIN PREFERRED METHOD NOTES: SCREWS MAY BE OMITTED SIZE BOLT(S)FOR LOAD 1. FIELD COORDINATE EXACT UNIT LOCATION.INSTALL UNIT UP IN BETWEEN IF HANGER LOOPS MEMBERS IF POSSIBLE. 2.PROVIDE SEISMIC BRACING PER IBC.IBC CODE REQUIREMENTS ARE PER SHEET METAL DUCT ROOF OPENING BETWEEN SCREWS SEE PLANS FOR SIZE JOISTS-FIELD SMACNA SEISMIC RESTRAINT MANUAL&ASCE 7 WAS NO �Q�OF Hiy To VERIFY LOCATION CAN SUPPORT 3201bs STRAP WIRE P DECOUPLED DOAS SYSTEM MAXIMUM. w TYPICAL HORIZONTAL FAN COIL ANGLE OR /AIR HANDLING UNIT INSTALLATION n GOOSENECK OUTSIDE AIR INTAKE- DETAIL CHANNEL n ROUND CEILING DIFFUSER DETAIL AEG3350 M501 NOT TO SCALE M501 NOT TO SCALE M5 1 NOT TO SCALE (�S+S,/GI Is e �/ BOTTOM REINFORCEMENT NAB INSULATE BLANKED OFF CLAMP AROUND DUCT LOW PRESSURE DUCT INSULATED OR ��/ /g PORTIONS OF LOUVER TO SAME WITH CAULKED JOINT SOUNDLINED AS SPECIFIED VALUE AS BUILDING EXTERIOR UP 12"MIN.TO HANGER STRAP TO THE BACKDRAFT OR 36"MAX.UNO 20 GA FLASHING (1"WIDE 20 GA) PHASE 2 ROCKCREEK CHURCH ARLINGTON (� MOTORIZED DAMPER,AS WELDED CORNER SEAMS `j APPROPRIATE C 730 E HIGHLAND DRIVE 22 GA.GALV.SHEET METAL 2X2 NAILER ARLINGTON, WA 98223 BLANK-OFF ALL UNUSED 45° 16 GA SHEET METAL SPIN-IN COLLAR WITH MANUAL MECHANICAL DRAWINGS PORTIONS OF LOUVER SEAL MAX CURB OR FIRE AROUND PERIMETER OF TYP. TREATED WOOD IF METAL CURB, VOLUME DAMPER.ORIENT DAMPER BLANK-OFF WITH SILICONE GC TO PROVIDE /j SHAFT PARALLEL TO DUCT AIR OWNER CAULK. LINO (BY GC) INSULATION LOAD RATED FASTENER J FLOW.GC TO PROVIDE ACCESS MARYSVILLE FREE METHODIST CHURCH VERIFY LOCATION LOUVER ROOFING DOOR IF DAMPER IS LOCATED SPRING LOCK 6715 GROVE ST, ON PLANS M (SEE MEMBRANE III IN AN INACCESSIBLE LOCATION. DUCT SIZE VARIES ARCH.DWG) UP ROOF CURB MARYSVILLE, WA 98270 SEE PLAN AND OVER TOP CANT STRIP INSULATED RIGID ROUND DUCT (BY GC) CA(BY T S EXTENSION AS REQUIRED R-7 INSULATION ON OUTSIDE AIR FLEXIBLE DUCT(12'MAXIMUM) MECHANICAL CONTRACTOR DUCTS,UP TO 24"0 SUPPORT FLEXIBLE DUCT UNIT CONNECTION/ RUNS OVER 36"ON 36" HEATER LOCATION MAXIMUM 25"0 TO 50"0 CENTERS. (UNDER 2800 CFM) .� SEAL FLEXIBLE DUCT LINER WITH DRAWBAND I I\\\ - ` •� AND SEAL VAPOR 1 v BARRIER WITH DUCT •Pm TAPE(TYP) SHEET METAL \ DUCT SLOPED PAN AT DS WITH CAULKED JOINTS; TYPICAL AIR DEVICES DRAIN TOWARDS LOUVER.TACK WELD TO ^^ ,, SM CAN AS REQUIRED. SLO E CURBROOF AS BOTTOM AS LOWER DUCT HANGER ATTACHMENTS AND EQUIPMENT SCHEDULE) V ULED(SEE PLANS TO ROOF AS NEEDED ^, TYPICAL INSULATED LOUVER FOR LEVEL INSTALLATION j NOT TO SCALE TYPICAL AIR DEVICE �•Y/ LIGHT DUCT CONNECTION n DUCT ROOF PENETRATION -DETAIL n FLEXIBLE CONNECTION M5 1 NOT TO SCALE M5 1 NOT TO SCALE MM5501 NOT TO SCALE R B B ADJUST 1/3 OF VERTICAL VANESATA45° A FLOOR OR ROOF ABOVE O O'A"MIN FIXED BLADE GRILLE- MOUNT WITH BLADES ANGLED UPWARD Q Q \ TO OBSTRUCT SIGHT LINE THRU GRILLE. ADJUST 2/3 OF \ HANGER STRAP GRI 1 DIAMETER STRAIGHT LLE WIDTH PER PLAN. HORIZONTAL VANES TOP INLET AT A 45° SAME SIZE GRILLE INSIDE ROOM WALL TO DECK RADIUS IX DIA. -BLADES ANGLED UPWARD ALL HANGER WIRES STUD SPACE TO BE CLEAR& 22.5°OR AS NOTED UNOBSTRUCTED BEHIND GRILLE 1/2 L MUST BE VERTICAL L (NOTSPLAYED) A 06 24 25 MECHANICAL 30%DO SET MECHANICAL 65%DO SET 10 23 25 MECHANICAL STUD DEPTH AS REQUIRED FOR PERMIT SET112 L RETURN/TRANSFER AIR CFM&STATIC 11 ADJUST 1/3 OF VERTICAL 's T-BAR CEILING LOSS APPROX.COMBINATION GRILLE HE GHT(STUD SIZE TO 6O BE 1/3 L��1/3 L��1/3 L VANES AT A 22.5°ANGLE A MAX.GRILLE IN 2X4 STUD)OR ADJUST 1/2 OF VERTICAL MARK DATE I DESCRIPTION DECREASE DESIGN AIRFLOW VANES DOWN 22.5°FROM LAY-IN DIFFUSER THROUGH GRILLE BASED ON HEIGHT 14 A A STRAIGHT ONES PROJECT NO: 2025-021 &STUD SIZE COMBINATION SECTION A-A T-BAR CEILING GRID CAD DWG FILE: M50.DWG A +D WALL CAVITY RETURN/TRANSFER DETAIL DOUBLE DEFLECTION DRAWN BY: OWN M501 NOT TO SCALE SIDEWALL REGISTER DETAIL n LAY-IN DIFFUSER W/DUCT DROP A CHK'D BY: DWN 1/2 L 1/2 L �M501 NOT TO SCALE COPYRIGHT: Moot NOT TO SCALE SHEET TITLE City of Arlington DETAILS SHEET Building Department APPROVED Kevin Olander- 11/18/2025 No changes authorized unless approved by 1 2 3 4 the Building Official M501 SHEET 1,' OF - 1 2 3 4 5 G AQUA AIR AQUA AIR ENGINEERING 12400 SE 38TH ST #50014 MINIMUM(4)'g"SUPPORT GRAVITY OR MOTORIZED BELLEVUE, WA 98015 RODS ATTACHED TO STRUCTURE BACKDRAFT DAMPER WWWA uaairen Ineerin .COn1 WITH VIBRATION ISOLATORS q 9 9 (IF SHOWN ON THE PLANS) FINISH UB: 605247933 DSEE FLOOR PLAN FLEXIBLE DUCT GRADE D FOR DUCT CONNECTOR(TYP) SIZE.PROVIDE RETURN DUCT BOARD OR SURROUNDED CONSULTANTS TRANSITION AS SHEET METAL ELBOW COMPACTED BACKFILL 36"OR REQUIRED(TYP) _ TO 95%DENSITY FREE GREATER L±j _L __________ OF LARGE ROCKS, PREFERRED, CLODS,AND DEBRIS ROUTE AS `. REQ'D.FOR COORDINATION W/OTHER PROVIDE DETECTION UTILITIES E TAPE ON ALL IN ERROU l• ��N/ 6"MIN CONIF ONIF NUO SS PIPE, CEILING— HINGED ACCESS PANEL BELT GUARD a, LIGHT FIXTURE SAND BED 6"BELOW rPEING FAN CABINET WITH ROTATE MOTOR TO SIDE AND ABOVE PE PIPING INTERNAL LINER AS OR BOTTOM POSITION WHEN 24X12 RETURN SPECIFIED INSTALLED ABOVE CEILING GRILLE IAtij N Q OF WASy��O,p IN-LINE FAN NOTE:EXTEND THROAT LENGTH TO PROHIBIT LINE OF NOTE: SIGHT THROUGH GRILLE AND BOOT. UNDISTURBED NATIVE EARTH y 1.PROVIDE SEISMIC BRACING PER SMACNA SEISMIC RESTRAINT MANUAL,IBC AND ASCE 7. 53350 �EGISTeR�� ass/ONM- TYPICAL IN-LINE FAN DETAIL (:j) SOUND LINED RETURN BOOT nBURIED PE PIPING TRENCH DETAIL 10/2S/A, M502 M502 NOT TO SCALE NOT TO SCALE MM5502 NOT TO SCALE �/ PHASE 2 ROCKCREEK CHURCH ARLINGTON C C 730 E HIGHLAND DRIVE ARLINGTON, WA 98223 HALF SCOOP OROBD, MECHANICAL DRAWINGS SEE EQUIPMENT SCHEDULE FOR OWNER CONFIRMATION MARYSVILLE FREE METHODIST CHURCH 6715 GROVE ST, MARYSVILLE, WA 98270 MECHANICAL CONTRACTOR VV 30° 30° " •J� I� V DOUBLE DEFLECTION DIFFUSER(TYP) B (T) ROUND DUCT SIDEWALL DIFFUSER DETAIL MM5502 NOTTOSCALE O 06 24 25 MECHANICAL 30%DO SET _27MECHANICAL 65%DO SET 10 23 25 MECHANICAL PERMIT SET MARK DATE 1 OESCRIPNON PROJECT NO: 2025-021 City of Arlington CAD DWG FILE: M50l.DWG Building Department DRAWN BY: OWN A APPROVED A CHK•D BY: DWN COPYRIGHT: Kevin Olander- 11/18/2025 No changes authorized unless approved by SHEET TITLE the Building Official DETAILS SHEET 1 2 3 4 M502 5 SHEEP - OF 14 1 2 3 4 5 G� AQUA AIR AQUA AIR ENGINEERING 12400 SE 38TH ST #50014 BELLEVUE, WA 98015 www.aquaairengineerirg.com 1-1/4"NG UBI: 605247933 (240 MBH) �� I l AH-M103 RELOCATE EXISTING GAS WATER l CONSULTANTS HEATERS AS REQUIRED. 2"NG l AH-M104 RECONFIGURE EXISTING NATURAL (400 MBH) AH-M105 GAS AND FLUE VENT 2"N G CONNECTIONS. \ (640 MBH) AH-M106 ° l 1-1/4"NG AH-M107 w\ (240 MBH)>- AH-M108 3/4"NG AH-M109 1"NG (-60 MBH) AH-M110 �� AH-M101 � 1"NG 1/2"NG AT 7"W.C.TO IANj N 2-1/2"NG c �\ (-120 MBH) 1/2"NG DISHWASHER ,Q�°FwAS"' 0, (880 MBH) �\ AH-M111 (-40 MBH) Q y•/ 2"NG AT 7"W.C. \ 1/2"NG 53350 1"NG �I TO EXISTING (-30 MBH)/ � ���cSSGISTER���� (80 MBH) GAS WATER \ �ON4 HEATERS / AH-M112 GAS SHUTOFF 2"NG �, VALVE g (-60 MBH) 1"NG 1"NG AT 7"W.C.TO PHASE 2 ROCKCRFFK CHURCH ARLINGTON C 2-1/2"NG 2"NG (--140 MBH) EXISTING RANGE& C 730 F HIGHLAND DRIVE (-130 MBH) OVEN ARLINGTON, WA 98223 (960 MBH) MECHANICAL DRAWINGS € 1/2"NG AT 7"W.C.TO FIREPLACE OWNER 2"NG (-30 MBH) MARYSVILLE FREE METHODIST CHURCH 6715 GROVE ST, (-270 MBH) MARYSVILLE, WA 98270 2-1/2"NG (960 MBH) MEawu'u CONTRACTOR 3"NG 1/2"NG (1,230 MBH) (--45 MBH) � 1/2"NG AT 7"W.C.TO EXISTING GAS B FURNACE \ B C/1 3"NG (1,275 MBH) � a O 1"NG AT 7"W.C. City of Arlington T Building Department APPROVED Y 06 24 25 MECHANICAL 30%DO SET 0 MECHANICAL 65%DO SET Kevin Olander- 11/18/2025 10 23 25 MECHANICAL PERMIT S11/05/25 No changes authorized unless approved by MECHANICAL PERMIT REVISION sET the Building Official MARK DALE DESCRIPTION PROJECT NO: 2025-021 CONNECT NEW 3"NG AT EXISTING METER. EXISTING GAS METER. CAD On nEe M601.Dwc LONGEST LINE LENGTH OF 250 FT AT (TYP 2) DRAWN BY: OWN A 7"W.C.COORDINATE WITH UTILITY 1° 3' 5' 10' 15, 25' A CHK'D BY: DWN COMPANY AS REQUIRED. SCALE: a"=1' COPYRIGHT: 2' 4' SHEET TTU o ISOMETRIC GAS PIPING DIAGRAM 1 2 3 4 5 P601 SHEET 15 OF 15 Permit#: 6808 Permit Date: 11/05/25 Permit Type: COMMERCIAL MECHANICAL Project Name: Rock Creek Church Phase 2 Applicant Johansen Mechanical Name: Applicant 16372 177th Ave SE Address: Applicant, City,Monroe, WA 98272 State,Zip: Contact: Rob Johnson Phone: 3607224310 Email: robj@johansenmech.com Scope of Work: PHASE 2 OF TENANT IMPROVEMENT OF EXISTING CHURCH BUILDING INCLUDING NEW FURNACES,NEW DOAS &DUCT HEATERS, COOLING COILS, AC UNITS, & CONDENSERS PER ENERGY CODE REQUIREMENTS. NEW DISTRIBUTION DUCTWORK, GRILLES, REGISTERS, &DIFFUSERS. Valuation: 440000.00 Square Feet: 12690 Number of I Stories: Construction VA Type: Occupancy A-3;Assembly Group: ID Code: Permit Issued: 11/19/2025 Permit Expires: 05/18/2026 Form Permit COMMERCIAL MECHANICAL Type: Status: COMPLETE Assigned To: Hannah Hardwick Property Parcel# Address Legal Description Owner Name Owner Phone Zoning MARYSVILLE 699 Other 31051100401000 730 E HIGHLAND DR FREE METHODIST Miscellaneous CHURCH Services NEC Contractors Contractor Primary Contact Phone Address Contractor Type License License# Johansen Mechanical Ivy LeVangie 425-481-2266 16372 177TH CONSTRUCTION UBI 600495164 Inc AVE SE CONTRACTOR Johansen Mechanical Ivy LeVangie 425-481-2266 16372 177TH CONSTRUCTION Labor&Industries JOHANMI173PK Inc AVE SE CONTRACTOR Johansen Mechanical Ivy LeVangie 425-481-2266 16372 177TH CONSTRUCTION Electrical JOHANMI969P7 Inc AVE SE CONTRACTOR Contractor Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status C 14. 03/12/2026 MECHANICAL 03/13/2026 03/13/2026 BUILDING Approved FINAL CIO. 02/10/2026 MECHANICAL Call Justin McGovern(206- 02/11/2026 02/11/2026 BUILDING Approved ROUGH-IN 510-3977)once on-site. C 14. O1/13/2026 MECHANICAL For the gas line 01/14/2026 01/14/2026 BUILDING Approved FINAL C14. O1/07/2026 MECHANICAL O1/08/2026 01/08/2026 BUILDING Approved FINAL Plan Reviews Date Review Type Description Assigned To Review Status COMMERCIAL Approved with 11/06/2025 MECHANICAL See note on page M401 BUILDING Conditions Fees Fee Description Notes Amount Enter 1 if permit is for commercial Web Only-Mechanical Commercial Plan mechanical $2,832.14 Review (Table 4-1) Credit Card Service $84.96 Processing/Technology $25.00 Gas Fired A/C>500 BTU/h Enter#of units $600.00 Gas Piping/Units Enter#of units $33.00 Mechanical Base Permit Fee $25.00 Mechanical Misc. Not otherwise specified $45.00 Refrigeration Unit>500 BTU/h Enter#of units $800.00 Credit Card Service $45.84 Total $4,490.94 Attached Letters Date Letter Description 11/19/2025 Building Permit 11/05/2025 Web Form-Building Application Payments Date Paid By Description Payment Type Accepted By Amount 11/05/2025 Laura Johansen 248019018 Hannah Hardwick $84.96 11/05/2025 XBP Con£ $2,832.14 248019018 11/19/2025 Laura Johansen cc LaNay Hendrick $45.84 11/19/2025 XBP Conf: $1,528.00 249322028 Outstanding Balance $0.00 Uploaded Files Date File Name 11/19/2025 29520056-2025 BLD6808 Issued Permit.pdf 11/19/2025 29520057-20251106 BLD6808 ApprovedPlans.pdf 11/05/2025 463c2d0aaad488lf7715b2be428ef5fe Commercial Mechanical Application - Rock Creek Church Phase 2 11.5.25.pdf 11/05/2025 13665a39a58dcfl3aael754le4714c81 2025-10-23 Arlington Rock Creek Church Mechanical Permit Set Phase 2.pdf 1 1 2 1 3 1 4 1 5 MECHANICAL ABBREVIATIONS MECHANICAL LEGEND GENERAL NOTES PARCEL NUMBER G`: AQUA AIR A AMPS IBC INTERNATIONAL BUILDING CODE 10 X10" RECT SUPPLY AIR DUCT 1. ALL WORK SHALL COMPLY WITH THE 2021 WASHINGTON STATE BUILDING CODE,2021 WASHINGTON STATE 31051100401000 AC AIR CONDITIONING TGW INDUSTRIAL COLD WATER �10"X1 O:X DP TOWARD MECHANICAL CODE,2021 WASHINGTON STATE PLUMBING CODE,2021 WASHINGTON STATE ENERGY CODE, AQUA, AIR ENGINEERING ACH AIR CHANGES PER HOUR ID INSIDE DIAMETER/DIMENSION ®I ,1 AND OTHER APPLICABLE FEDERAL,STATE,OR LOCAL CODES AS ADOPTED AND ENFORCED BY THE LOCAL ACT ACOUSTICAL CEILING TILE IE INVERT ELEVATION 10"X1 Q" JURISDICTION.IN CASE THE PLANS SHOW MORE STRINGENT REQUIREMENTS,THE PLANS SHALL GOVERN THE 12400 SE 38TH ST 1r 5001 4 AD ACCESS DOOR IEER INTEGRATED ENERGY EFFICIENCY RATIO � RECT SUPPLY AIR DUCT DESIGN,YET NOTHING ON THE DESIGN DOCUMENTS SHALL BE INTERPRETED AS AUTHORITY TO VIOLATE LEGAL DESCRIPTION BELLEVUE, WA 98015 10"X10" DN AWAY CODE(S)OR REGULATION($). ADD'L ADDITIONAL INC INTERNATIONAL MECHANICAL CODE �© / SEC 11 TWP 31 RGE 05 BEG 1/4 COR E BDY 11-31-05 TH SLY ALG E LN SD www.aquaairengineering.com AFF ABOVE FINISHED FLOOR IN INCHES 10"X1O" 2. SUBMISSION OF BID IN CONNECTION WITH THIS WORK SHALL IMPLY THAT THE BIDDER HAS EXAMINED THE UBI. 605247933 AFG ABOVE FINISHED GRADE IN WG INCHES WATER GAUGE RECT RETURN DUCT JOB SITE UNDER WHICH THE CONTRACTOR WILL BE OBLIGATED TO OPERATE UNDER THIS CONTRACT.NO SEC LN 20.03FT TH ANG R 87*0612120.04FT TO TPB TH CONT ON LAST AHU AIR HANDLING UNIT IPLV INTEGRATED PART LOAD VALUE TOWARD UP 10"X10° / EXTRA CHARGE WILL BE ALLOWED FOR FAILURE OF ANY BIDDER TO EXAMINE THE SITE PRIOR TO BID. �® DESC COURSE 180FT TH ANG L 87 06 12 150FT TH ANG L 92 53 48 D ALUM ALUMINUM KW KILOWATTS D AMP/AMPS AMPERAGE LAT LEAVING AIR TEMPERATURE 10"X1O" RECT RETURN DUCT 3. WHERE USED,THE TERM"PROVIDE"SHALL MEAN"FURNISH AND INSTALL". 18OFTTH ANG L 87*06 12 150FT TO TPB TGW COM NE COR NE1/4 NE-1/4 DONs1ILTANTs AP ACCESS PANEL BLADE ECT LF/LIN FT LINEAL FOOT/FEET LB/U POUND/POUNDS toiicz DN/AWAY 4. IN THE EVENT OF A CONFLICT OR INCONSISTENCY BETWEEN ITEMS INDICATED ON DRAWINGS AND TH W ALG N LN SD SUB 392.88FT M/L TH ANG L 81*48 49 DIST 169.92FT ARCH SPECIFICATIONS WITH CODE REQUIREMENTS,THE MORE STRINGENT STANDARD SHALL PREVAIL. BC BEADED COLLAR LPG LIQUID PROPANE GAS 10"X10" RECT EXHAUST TPB TH CONT SLY 297FT TH E TAP ON E LN 465.03FT S OF NE COR TH N BDD BACKDRAFT DAMPER LPS LOW PRESSURE STEAM 1O"X1OQ"�I DP OWARD 5. CARE SHALL BE EXERCISED TO MINIMIZE ANY INCONVENIENCE OR DISTURBANCE TO OTHER AREAS OF THE BF BELOW FLOOR LVG LEAVING BUILDING WHICH ARE TO REMAIN IN OPERATION.ISOLATE WORK AREAS TO KEEP DUST AND DIRT WITHIN THE ALG E LNTAP 170.03FTS OF NE COR SD SUBTH WILY TO TPB&TGW BAAP BHP BRAKE HORSEPOWER UNA SOUND POWER RATING LEVEL(IN DB) 10"X1o" RECT EXHAUST CONSTRUCTION AREA. 20FT S&393FT W OF 1/4 COR ON E LN SEC TH S 455.6FT TH W 20OFT TH N BLDG BUILDING LWG LOW WALL GRILLE 10"X10" /DN AWAY BOO BOTTOM OF DUCT LWT LEAVING WATER TEMPERATURE �© 6. NO PIPING,EQUIPMENT,ETC.SHALL BE REMOVED,DISCONNECTED OR SHUT DOWN WITHOUT PRIOR REVIEW 285.6FT THE 100FT TH N 115.6FT TH E 100FT TPB LESS RD&LESS V 864 P BOP BOTTOM OF PIPE MAX MAXIMUM WITH THE OWNER TO CONFIRM THAT AREAS TO REMAIN IN OPERATION WILL NOT BE AFFECTED.IF ANY AREAS BOT BOTTOM MAU MAKE UP AIR UNIT 1O"® NOT WITHIN THE SCOPE OF WORK ARE AFFECTED BY ANY SHUTDOWN,REMOVAL OR DISCONNECTION, 490FOR CITY ST LESS RD R/vv^, TO CITY OF ARL PER QCD REC AFN BS BIRD SCREEN BLACK STEEL MBH 1000 BRITISH THERMAL UNITS HOUR ROUND DUCT- UP TOWARD SUFFICIENT ADVANCE NOTICE MUST BE GIVEN TO THE OWNER INDICATING WHICH AREAS WILL BE AFFECTED, BTU BRITISH THERMAL UNIT MCA MINIMUM CIRCUIT AMPACffY / / ® / WHEN THE PROPOSED SHUTDOWN WILL OCCUR,AND FOR HOW LONG A PERIOD OF TIME. 9809220489(EXEMPT PER ST OF WA REG#01414-001) BTUH BRITISH THERMAL UNTS PER HOUR MD MOTORIZED DAMPER 7. THE ARRANGEMENT OF EQUIPMENT AND PIPING SHOWN ON THE DRAWINGS IS BASED UPON INFORMATION CAP CAPACITY MFR MANUFACTURER ROUND DUCT- ON/AWAY 10•0 /!Y AVAILABLE TO THE ENGINEER AT THE TIME OF DESIGN AND IS NOT INTENDED TO SHOW EXACT DIMENSIONS. gel Of The O _ LIA CBD CALIBRATED BALANCING DAMPER MISC MISCELLANEOUS �J THIS CONTRACTOR SHALL VERIFY ALL DIMENSIONS AT THE SITE MAKING FIELD MEASUREMENTS AND SHOP CC CONTROLS CONTRACTOR MIN MINIMUM/MINUTE DRAWINGS NECESSARY FOR FABRICATION OR ERECTION OF HVAC SYSTEMS.MAKE ALLOWANCE FOR BEAMS, (n¢�Res¢ � CD CEILING DIFFUSER/CONDENSATE DRAIN MPS MEDIUM PRESSURE STEAM 12"X10"0 FLATOVAL DUCT- UP/TOWARD PIPES AND OTHER OBSTRUCTIONS IN BUILDING CONSTRUCTION.CHECK DRAWINGS SHOWING WORK OF j CDWR CONDENSER WATER RETURN MT MOUNT OTHER TRADES AND CONSULT WITH THE OWNER'S REPRESENTATIVE IN THE EVENT OF POTENTIAL w CDWS CONDENSER WATER SUPPLY MTD MOUNTED 12"X10"0 FLATOVAL DUCT- ON/AWAY -N INTERFERENCE.SHOP DRAWINGS SHALL BE MINIMUM 1/4"=1'-0"SCALE,INDICATING FITTINGS,SIZES,WELDSin ION CFM CUBIC FEET PER MINUTE MUW MAKE-UP WATER AND CONFIGURATIONS AND SUBMITTED TO ENGINEER FOR REVIEW Arlington 4 CHWR CHILLED WATER RETURN NA NOT APPLICABLE Heights O� QE53350 10"0 o DUCT OVERLAP 8. THIS CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER TRADES PRIOR TO FABRICATION, rlington �s GISTeR CLG CHILLED WATER SUPPLY NC NORMALLY CLOSED/NOISE CRITERIA PURCHASE AND/OR INSTALLATION OF ALL WORK, Arlington Hardware S/ONAIL CLG CEILING NG/NGAS NATURAL GAS 10"0 T. &Lumber,Inc. COL COLUMN NIC NOT IN CONTRACT BOOT TAP 9. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT COMPLIANCE WITH THE MANUFACTURER'S WRITTEN I0I83IEs CONIC CONCRETE NO NORMALLY OPEN/NUMBER 10"0 INSTRUCTIONS. • COND CONDENSATE NPW NON-POTABLE WATER - PHASE 2 ROCKCREEK CHURCH ARLINGTON CONN CONNECT/CONNECTED/CONNECTION N-R NON-RESIDENTIAL 10"0 45'TAP 10. THIS CONTRACTOR SHALL NOT BORE,NOTCH,CUT,OR PENETRATE INTO A STRUCTURAL MEMBER WITHOUT ()Safeway River CONTINUATION OA OSA OUTSIDE AIR WRITTEN APPROVAL FROM A DESIGNATED STRUCTURAL ENGINEER AND THE OWNER. Meadows© 730 E HIGHLAND DRIVE CONT CONTINUOUS/ / C¢u ea Park C CONTR CONTRACTOR OBD OPPOSED BLADE DAMPER ` ARLINGTON, WA 98223 COORD COORDINATE OD OUTSIDE DIAMETER/DIMENSION VOLUME DAMPER 11, INSTALL MANUAL VOLUME DAMPERS WITHIN DUCT BRANCHES TO BALANCE AIRFLOW CFM.ON INSULATED COP COEFFICIENT OF PERFORMANCE PCF POUNDS PER CUBIC FOOT 1010-o DUCTS,MOUNT DAMPER REGULATOR ON 2"STAND-OFF BRACKET TO CLEAR INSULATION. MECHANICAL DRAWINGS CT COOLING TOWER PD PRESSURE DROP 101-0 CALIBRATED BALANCING DAMPER 12. COORDINATE ACCESS TO EQUIPMENT WITH WORK OF OTHER TRADES.PROVIDE DUCT ACCESS DOORS AND OWNER CU CUBIC/CONDENSER UNIT PH PHASE CEILING ACCESS DOORS TO ALLOW ACCESS FOR FILTER CHANGEOUT,CONTROLS ACCESS AND ACCESS TO Ailing¢n �' MARYSVILLE FREE METHODIST CHURCH CW DOMESTIC COLD WATER/CONDENSER WATER POC POINT OF CONNECTION W RISE(R)&DROP(D) SERVICE REMOVE COMPONENTS INCLUDING,BUT NOT LIMITED TO,FANS,PULLEYS,SHEAVES,BELTS,ETC. Municipal 6]15 GROVE ST, DB DUCTBOARD/DRY BULB/DECIBEL P/PRESS PRESSURE l� Airport 0 DDC DIRECT DIGITAL CONTROL PSI POUNDS PER SQUARE INCH T 13. PROJECT CLOSE OUT DOCUMENTATION AND TRAINING OF BUILDING OPERATIONS PERSONNEL IS REQUIRED (AWO) MARYSVILLE, WA 98270 r DO TRANSITION FOR ALL MECHANICAL COMPONENTS,EQUIPMENT AND SYSTEMS PER WSEC C103.6. TEFL DEFLECTION PSIG POUNDS PER SQUARE INCH GAUGE DEG DEGREE/DEGREES QTY QUANTITY TURNING VANES/SPUTTERS 14. CONSTRUCTION TO ADHERE TO BUILDING STANDARDS AS APPLICABLE.FLEX DUCT TO BE MAXIMUM 12 FEET MECHANICAL CONTRACTOR DIA DIAMETER R RETURN GRILLE/RELOCATED/RETURN V p IN LENGTH FLEX DUCT MAYBE UP To 25 FEET LONG IF SIZED UP ONE SIZE, DMPR DAMPER RA RETURN AIR DUCT MOUNTED SMOKE DETECTOR VICINITY MAP DN DOWN RD/RND ROUND DOAS DEDICATED OUTSIDE AIR SYSTEM REF REFERENCE BACK DRAFT DAMPER NO SCALE ; DWG DRAWING REQ REQUIRED FLEXIBLE DUCT SHEET INDEX IXH EXHAUST RESID RESIDENTIAL AIR FLOW FORCED AIR ( ) SHEET DESCRIPTION EA EACH RF RELIEF J REV EAT EAT ENTERING AIR TEMPERATURE RG REFRIGERANT DISCHARGE GAS Moot GENERAL NOTES,LEGEND,SHEET INDEX AND ABBREVIATIONS r EC EGGCRATE GRILLE/END CAP/ELEC CONTRACTOR RL REFRIGERANT LIQUID {• , EER ENERGY EFFICIENT RATING RPM REVOLUTIONS PER MINUTE M002 SCHEDULEs SHEET EF EXHAUST FAN IRS REFRIGERANT SUCTION COMBINATION FSD Moo 3 SCHEDULES EFF EFFICIENCY S SUPPLY EL ELEVATION SA SUPPLY AIR FIRE DAMPER Moo4 SCHEDULES AND CALCULATIONS SHEET coo ELEC/ELECT ELECTRICAL/ELECTRIC SAT SATURATION/SUPPLY AIR TEMPERATURE SMOKE DAMPER EMCS ENERGY MANAGEMENT CONTROL SYSTEM SD SMOKE DETECTOR MOTOR OPERATED DAMPER MD201 LEVEL MECHANICAL DEMO PLAN ENT ENTERING S/D SUP& DRIVE CONNECTION &�U64RSL ACOUSTICALLY LINED DUCT MD202 MEZZANINE LEVEL MECHANICAL DEMO PLAN EQUIP EQUIPMENT S-C SEATTLE_CODE OD =OUTSIDE DIMENSIONS t r f e if r ESP EXTERNAL STATIC PRESSURE SEER SEASONAL ENERGY EFFICIENCY RATING SL=SOUND LINING(THICKNESS) M201 LEVEL MECHANICAL HVAC PLAN B EWT ENTERING WATER TEMPERATURE SENS SENSIBLE B MP201 LEVEL 1 MECHANICAL PIPING PLAN EXIST/(E) EXISTING SL SOUND LINED ® CLEARANCE � ,t _ �E C.IIIIII IXH EXHAUST SM SHEETMETAL ® SUPPLY AIR DIFFUSER M202 MEZZANINE LEVEL MECHANICAL HVAC PLAN F FAHRENHEIT SPEC SPECIFICATION ���JJS FAC FIRE ALARM CONTRACTOR SO SCREENED OPENING (WITH CORE BLANKOFF/ROTATE) MP202 MEZZANINE LEVEL MECHANICAL PIPING PUN ' 1 06FD FIRE DAMPER SOG SLAB ON GRADE COUNG EXHAUST AIR GRILLE M203 ROOF MECHANICAL PLAN I �" FDC FIRE DEPARTMENT CONNECTION SP STATIC PRESSURE ® FF FINISHED FLOOR SF SQUARE FEET Z COUNG RETURN OR TRANSFER M401 MECHANICAL ELEVATIONS PLAN I lil FIC FURNISHED AND INSTALLED BY CONTRACTOR SS STAINLESS STEEL AIR GRILLE FIO FURNSHED AND NSTALLED BY OWNER STRUC STRUCTURAL o SLOTTED DIFFUSER(PLAN VIEW) M501 DETAILS SHEET FLA FULL LOAD AMPS TA TRANSFER AIR M502 DETAILS SHEET FLEX FLEXIBLE TEMP TEMPERATURE/TEMPORARY x REVISION CLOUD&TRIANGLE FUR FLOOR TBD TO BE DETERMINED #J10 ROUND DUCT SYMBOL FOB FLAT ON BOTTOM TOD TOP OF DUCT ##X '0 FLATOVAL DUCT SYMBOL FOIC FURNISHED BY OTHERS, TOS TOP OF STEEL/TOP OF SLAB / DEGREES SYMBOL INSTALLED BY CONTRACTOR TOT TOTAL A POINT OF CONNECTION FOS FLAT ON SIDE TSP TOTAL STATIC PRESSURE CD1-100 GIRD TAG IDENTIFIER = TYPE-CFM FOT FLAT ON TOP TSTAT THERMOSTAT 8"0 SIZE SITE MAP FP FIRE PROTECTION TYP TYPICAL 0T'sw/TEMP SENSOR ®CARBON DIOXIDE NO SCALE FPM FEET PER MINUTE UH UNIT HEATER QH HUMIDITY SENSOR SENSOR 06 24 25 MECHANICAL 30%DID SET FT FOOT/SMOTE DAMPER LINO UNLESS NOTED OTHERWISE sD SMOKE DETECTOR VOLT ©0 CARBON MONOXIDE D 2a 25 MECHANiicnE PERMIT5%DID SET FUT FUTURE VD VOLUME DAMPER sP STATIC PRESSURE SENSOR SENSOR MINIMUM PIPE I N S U LATIO N FV FACE VELOCITY VEL VELOCITY 0 OCCUPANCY SENSOR QS SENSOR FLUID DESIGN INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER(INCH) G GRILLE VERT VERTICAL O OPERATING �CONDIJCTIVTY MEANTEMP 1T0 1-112T0 4TO MARK DATE DESCRIPIION GA GAUGE/GALLON VFD VARIABLE FREQUENCY DRIVE TEMP°F RANGE RATING°F <1 <1-112 <4 <8 ?8 GALV GALVANIZED VOL VOLUME EXISTING DUCTWORK HEATING SYSTEMS"(STEAM,CONDENSATE,HYDRONIC HOT WATER,DOMESTIC HOT WATER,DOMESTIC HOT WATER RECIRCULATION) PROJECT NO: 2025-021 GC GENERAL CONTRACTOR W WRAPPED DUCT DEMO DUCTWORK >350= 0.32-0.34 250 1 4.5 1 5 1 5 5 5 CAD DWG FILE: moor.DwG GPM GALLONS PER MINUTE WB WET BULB 251-350 0.29-0.32 200 3 4 4.5 4.5 4.5 DRAWN BY: OWN GRD GRILLE/REGISTER/DIFFUSER WG WATER GAUGE �I WALL-MOUNTED GRILLE 201-250 0.27-0.30 150 2.5 2.5 2.5 3 3 A GWB GYPSUM WALL BOARD W/ WITH 141-200 0.25-0.29 125 1.5 1 1.5 1 2 2 2 A CHK'D BY: DWN HD HEAD W/o WITHOUT PIPE ELBOW UP 105-140 0.21-0.28 100 1 1 1 1 1.5 1.5 1.5 COPYRIGHT: HORIZ HORIZONTAL W/SF WATTS PER SQUARE FOOT PIPE ELBOW ON DOMESTIC COLD WATER AND HORIZ RAIN LEADERS TO VERTICAL RAIN LEADER(TO PREVENT CONDENSATION ONLY) HP HORSEPOWER WSEC WASHINGTON STATE ENERGY CODE a e DIRECTION OF FLOW NA 1 0.21-0.27 1 75 1 0.5 1 0.5 1 1 1 1 z � DIRECTION OF SLOPE DOWN sHEEr TITLE HR HOUR COOLING SYSTEMS"(CHILLED WATER,BRINE AND REFRIGERANT,WATERSIDE ECONOMIZER SYSTEMS"") HSPF HEATING SEASONAL PERFORMANCE FACTOR PLUG OR CAP 40-60 0.21-0.27 1 75 1 0.5 1 0.5 1 1 1 1 GENERAL NOTES, HT HEIGHT 2-CHWS/tHWR5 CHILLED WATER SUPPLY/RETURN <40 0.20-0.26 1 75 1 0.5 1 1 1 1 1.5 HWTG HIGH WALL TRANSFER GRILLE -RL/RS- REFRIGERANT LIQUID/SUCTION LEGEND SHEET INDEX HWR HOT WATER RETURN 1-NG NATURAL GAS NOT REQUIRED FOR STRAINERS,CONTROL VALVES&BALANCING VALVES ASSOCIATED WITH PIPING 1"OR LESS IN DIA. HWS HOT WATER SUPPLY z- LPG LIQUID PROPANE GAS -TYPICAL CONDENSER WATER PIPE IN NON-ECONOMIZER SYSTEMS IS NOT INSULATED AND ABBREVIATIONS HX HEAT EXCHANGER z-CDWS/tDWRS CONDENSER WATER SUPPLY/RETURN SEE R403 FOR RESIDENTIAL INSTALLATIONS HZ HERTZ Z--HWS/HWR- HEATING WATER SUPPLY/RETURN 1 2 3 4 5 M001 SHEET I OF - 1 2 3 1 4 5 ENERGY RECOVERY VENTILATOR SCHEDULE G AQUA AIR TIME OUTSIDEAIR EXHAUST AIR ELECTRICAL ENTHALPY EQUIP AQUA AIR ENGINEERING UNIT AREA OF EAT"F LAT"F EAT°F LAT°F FAN PER MOTOR OVERALL CORE WGT TAG LOCATION SERVED BASIS OF DESIGN YEAR CFM DB WB DB WB CFM DB WE DB WB V/PH BHP HP ESP TSP WICFM CTRL FLA MCA FLA MCOP EFF% LBS NOTES 12400 SE 38TH ST #50014 SANCTUARY& RENEWAIRE SUM 2,100 80.8 63.8 77 62.6 2,100 75 62.5 - - 64% BELLEVUE, WA 98015 DOAS-Mi MEZZANINE FOYER HE-3XJINV-S15WW WIN 2,100 25.5 21.2 58 43.4 2,100 70 51.3 - - 20811 1.17 3 1.5 2.2 0.42 VFD 7.3 28.4 14.6 40 69% 754 1-12 WWW.aqu001TEF1gN122TIng.001Y1 -DWNT---L - - - UBI: 605247933 SANCTUARY& RENEWAIRE SUM 2,100 80.8 63.8 77 62.6 2,100 75 62.5 - - 64% D DOAS-M2 MEZZANINE FOYER HE-3XJINV-S15WW WIN 2,100 25.5 21.2 58 43.4 2,100 70 51-3 - - 208/1 1.17 3 1.5 2.2 0.42 VFD 7.3 28.4 14.6 40 69% 754 1-12 D -DWNT---L DAIKIN SUM 170 86 67 170 75 62.5 OONSULTMTTS DOAS-3 OFFICE OFFICE VAM300GVJU WIN 170 24 20 170 70 60 208/1 307 W 0.16 C403.8.1 ECM 1.6 15 71 GENERAL: ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION& INSTALL PER MANUFACTURERS REQUIREMENTS NOTES: 1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTECTION DIRECTION FOR EQUIPMENT AS REQUIRED BY LATEST APPROVED VERISON OF THE NATIONAL ELECTRICAL CODE,PRIOR TO ORDER. MANUFACTURER TO PROVIDE SCCR LISTING(5 KAIC MINIMUM OR PER ELECTRICAL CONTRACTOR CALCULATION)INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. 2 ULIETL LISTED UNIT.SUPPLYAND EXHAUST FAN MOTORS TO BE CAPABLE OF ADJUSTABLE SPEEDS. 3 PROVIDE FACTORY SUPPLIED AND MOUNTED VFD DRIVES FOR BOTH SUPPLYAND EXHAUST FAN TO ACCOMMODATE FILTER LOADING 4 MFG TO PROVIDE 2"FILTER RACK WHERE AVAILABLE AS ACCESSORY FOR MERV-8 FILTERS FOR OUTSIDE AIRFLOW SYSTEM AND MERV-8 FILTERS FOR EXHAUSTAIRFLOW SYSTEM. 5 PROVIDE FLOOR CURB FOR UNIT MOUNTING 6 WITH OUTDOOR AIR MONITORING SYSTEM,EBTRON AIR-IQ AFMD OR EQUAL(PROVIDED AND INSTALLED BY CONTROLS CONTRACTOR) 7 UNIT TO OPERATE CONTINUOUSLY DURING OCCUPIED HOURS,DECOUPLED FROM CENTRAL SYSTEM PER C403.6.2 8 MINIMUM UNIT EFFICIENCY TO MEET THE ENERGY CODE TABLEC403.5.1 9 INSULATE OSA INTAKE AND EXHAUST DUCTWORK FROM EXTERIOR UP TO THE ERV UNIT,AND SUPPLY DUCTWORK IF LEAVING TEMPERATURE IS<55'F Q of wnsyti O,p 10 PROVIDE SEISMIC BRACING PER ACSE 7,UNLESS:UNIT<20 LBS OR IS RIGID MOUNTED INLINE WITH DUCT(NO FLEX)AND<75 LBS OR<400 LBS WITH FLEX CONN'S&Ip=1.0&4'MAX MOUNT HEIGHT AFF 11 UNIT WITH FIXED PLATE HEAT EXCHANGER w _ 12 SUPPLY FAN AND EXHAUST FAN SPEED LINKED TO STATIC PRESSURE SETTING IN SA DUCT.STATIC PRESSURE SETTINGS TO MATCH ASHRAE GUILDINE 36 FOR VAV SUPPLY AHU AT a0.06"WC AND MAX•0.13"WC. 53350�EGISTER�� ass/ONAlL DUCT HEATER SCHEDULE 1012S/g UNIT MANUFACTURE HEATER TOTAL TEMP WINTER TSTAT DUCT DIMENSION ELECTRICAL WEIGHT TAG LOCATION SERVES &MODEL KW CFM RISE"F LAT"F LOCATION WIDTH(IN) HEIGHT(IN) FLA VIPH MOCP LBS NOTES PHASE 2 ROCKCREEK CHURCH ARLINGTON DH-M1 MEZZANINE DOAS-MI RENEWAIRE EK-1611004SCCVR 4 2100 6.0 61.0 IN HEATER 16 12 19.23 20811 25 1,2,3,4,5,6,7,8 (� 730 E HIGHLAND DRIVE C SPIRAL MOUNT REGISTER SCHEDULE DH-M2 MEZZANINE DOAS-M2 RENEWAIREEK-1611004SCCVR 4 2100 NHEATER 16 12 19.23 20811 25 1,2,3,4,5,6,7,8 ARLINGTON, WA 98223 UNIT BASIS OF DUCT MAX CORE FACE THROW GENERAL MECHANICAL DRAWINGS TAG DESIGN INMN8 CFM SIZE SIZE 9/10/15 23 MOUNTING MATERIAL REMARKS ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS ELECTRICAL,WEIGHT,SIZE,ETC...WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL PER MANUFACTURERS REQUIREMENTS SMi SHOEMAKER RS34 MIN8 150 12 X4 14X6 9110/15 23 DUCT STEEL 1,2,3,4,5 ( ) OWNER SM2 SHOEMAKER RS34 MIN 10 225 12X6 14X8 12/13118 20 DUCT STEEL 1,2,3,4,5 1 ELECTRICAL CONTRACTORTO PROVIDE SCCR PROTECTION DIRECTION FOR EQUIPMENTAS REQUIRED BY LATESTAPPROVED VERISON OF THE NATIONAL ELECTRICAL CODE,PRIOR TO ORDER. MARYSVILLE FREE METHODIST CHURCH SM3 SHOEMAKER RS34 MIN 10 350 16 X 6 18 X 8 15/17/23 26 DUCT STEEL 1,2,3,4,5 MANUFACTURER TO PROVIDE SCCR LISTING(5 KAIC MINIMUM OR PER ELECTRICAL CONTRACTOR CALCULATION)INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. 6]15 GROVE ST, SM4 SHOEMAKER RS34 MIN 12 450 16 X 8 18 X 10 17/19/26 25 DUCT STEEL 1,2,3,4,5 2 PROVIDE(NEMA 1 RATED STANDARD INDOOR/NEMA 4 RATED ENCLOSURE FOR OUTDOORNdATER PROTECTION)ENCLOSURE SMS SHOEMAKER RS34 MIN 12 525 18X8 20X10 17/20/27 25 DUCT STEEL 1,2,3,4,5 3 PROVIDE(SLIP INIFLANGEDICOLLAR)CONNECTION,AIRFLOW SWITCH,THERMAL CUTOFF PROTECTION,(MAGNETICIMERCURY)CONTACTORS, MARYSVILLE, WA 98270 SM6 SHOEMAKER SD34 MIN 150 12 X4 14 X6 9/10/15 23 DUCT STEEL 1,2,3,4,5 4 PROVIDE24V CONTROL TRANSFORMER,(ELECTRONICISCR)CONTROLS,(DUCTIROOM)T'STAT SETAT60-F SM7 SHOENIAKERSD34 MIN 10 225 12 X6 14X8 12/13/18 20 DUCT STEEL 1,2,3,4,5 5 PROVIDE DISCONNECT SWITCH SM8 SHOEMAKER SD34 MIN 10 350 16 X6 18 X8 15/17/23 26 DUCT STEEL 1,2,3,4,5 6 INTERCONNECTION CONTROL WIRING BETWEEN AIR DELIVERYUNFTS(TRANSFER FAN)AND HEATERS BYCONTROLS CONTRACTOR MECHANICAL CONTRACTOR SM9 SHOEMAKER SD34 MIN 12 450 16 X 8 18 X 10 17/19/26 25 DUCT STEEL 1,2,3,4,5 7 HEATING FAN SHALL SHUT OFF WHEN THERE IS NO CALL FOR HEATING AND COOLING IN THE ZONE PER 2021 WSEC C403.3.5.2,EXCEPT IF HEATING FAN<0.12W/CFM SM10 SHOEMAKER SD34 I MIN 12 1 525 1 18 X 8 20 X 10 17/20/27 1 25 1 DUCT I STEEL 1,2,3,4,5 8 HEATING CONTROLS BY SCR HEAT GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS �M U PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL PER MANUFACTURERS REQUIREMENTS REMARKS: 1 PROVIREFER ODRWING WITH SED FORDUEDAMPERIZEDIA DIAMETER INDOOR FAN COIL UNIT SCHEDULE 2 REFER TO DRAWINGS FOR DUCT SIZE DIAMETER TO BE ATTACHED TO(MUST EXCEED CORE HEIGHT BY 4"MINIMUM) 3 STANDARD GALVANIZED FINISH,CUSTOM COLORS ONLY IF SPECIFIED BYARCHITECT ASSOCIATED ESP COOLING REFRIGERANT CONNECTION �I 4 REGISTER SHALL BE SIZED FOR CORE SIZE AND SPIRAL DUCT DIAMETER UNIT MANUFACTURE OUTDOOR OSA IN CAPACITY MBH[31 SUCT LID DRAIN ELECTRICAL SOUND WEIGHT 5 THROW BASED ON 100 FPM TERMINAL VELOCITY TAG LOCATION SERVES &MODEL TYPE UNIT CFM CFM WG TOTAL SENS. IN IN IN MCA I VIPH dBA LBS NOTES �I IU-101 OFFICE 123 OFFICE GOODMAN AHVE24BP1300 DUCTED ODU-101 800 170 0.6 23.9 =.73"J5 3/4 318 3/4 4.9 208/1 115 1,2,3,5,6,7,9,10,11 IU-102 GREEN RM 114 AV SYSTEM DAIKIN FTX30WVJU9 WALL ODU-102 727 - 0.6 31.4 1 31.4 5/8 114 3/4 208/1 47 38 1,2,3,4,6,8,9,10,11 V GENERAL ALL TRADESTO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION& ROUND DIFFUSER SCHEDULE INSTALL PER MANUFACTURERS REQUIREMENTS UNIT BASIS OF NECK MAX OPENING OUTSIDE 1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTECTION DIRECTION FOR EQUIPMENT AS REQUIRED BY LATEST APPROVED VERISON OF THE NATIONAL ELECTRICAL CODE,PRIOR TO ORDER. TAG DESIGN TYPE SIZE CFM 0INCH 01NCH NC MOUNTING MATERIAL REMARKS MANUFACTURER TO PROVIDE SCCR LISTING(5 KAIC MINIMUM OR PER ELECTRICAL CONTRACTOR CALCULATION)INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. ^y B RD1 TITUSTMRA ROUND CEILING 6" 140 12 131/2 25 EXPOSED STEEL 1,2 2 R-32 REFRIGERANT,VERIFY MAXIMUM TOTAL SYSTEM REFRIGERANT LINE LENGTH AND MAXIMUM LIFT WITH MANUFACTURER/VENDOR.VERIFY ACCEPTABLE REFRIGERANT LINE SIZING,LENGTHS AND LIFTS WITH B ice) RD2 TITUSTMRA ROUND CEILING 8" 240 16 18 26 EXPOSED STEEL 1,2 MANUFACTURER PROVIDED SIZING PROGRAM RD3 TITUSTMRA ROUND CEILING 10" 350 20 221/2 24 EXPOSED STEEL 1,2 3 PRESSURE TEST REFRIGERANT PIPING AT 600 PSI �1 RD4 TITUS TMRA ROUND CEILING 12" 510 24 27 25 EXPOSED STEEL 1,2 4 NON DUCTED UNIT:PROVIDE CONDENSATE DRAIN PUMP(I.E.GOBI 230-XL-2.5 GPH @ 10 FT LIFT&<100 FT HORIZ,115V/1 PH @ 32W,5 LBS).TERMINATE CONDENSATE DRAIN PIPING INTO NEAREST RD5 TTUSTMRA ROUND CEILING 14" 660 28 31 1/2 23 EXPOSED STEEL 1,2 HUBIFLOOR DRAIN;CONDENSATE DRAIN PIPING BY PLUMBING CONTRACTOR RD6 TITUS TMRA ROUND CEILING 16" 860 32 36 24 EXPOSED STEEL 1,2 5 DUCTED UNIT:PROVIDE PLENUM RATED CONDENSATE PUMP(I.E.LITTLE GIANT MODEL VCC-20-P,55 GPH AT 4 FT LIFT-1/30HP @ 115Vll PH)ROUTED TO NEAREST INDIRECT DRAIN LOCATION; RN TFUSTM A, ROUND CEILING 18" 1080 36 40112 24 EXPOSED STEEL 1,2 CONDENSATE DRAIN PIPING BY PLUMBING CONTRACTOR.PROVIDE FIELD FABRICATED MIXING BOX WITH 2"FILTER RACK AND FILTER ACCESS DOOR.PROVIDE PLENUM RATED OVERFLOW SHUT-OFF RD8 TITUS TMRA ROUND CEILING 20" 1340 40 45 V2 25 EXPOSED STEEL 1,2 DEVICE CONFORMING TO ILL (I.E.RECTORSEAL SS2AP)IN LIEU OF SECONDARY DRAIN PAN RD9 TITUSTMRA ROUND CEILING 24" 1890 1 48 1 541/2 25 EXPOSED STEEL 1,2 6 OUTSIDE AIR INDICATES MINIMUM CFM PER ASHRAE.TAB WORK MUST MEET OR EXCEED INDICATED QUANTITY. GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS 7 ECONOMIZER EXEMPT PER 2021 WSEC C403.5 EXCEPTION 1 B DOAS ERV PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL PER MANUFACTURERS REQUIREMENTS 8 ECONOMIZER EXEMPT PER 2021 WSEC C403.5 EXCEPTION 9 ELECTRONIC EQUIPMENT ROOM 1 RUN OUT SIZE SAME SIZE AS DIFFUSER NECK SIZE,U.N.O.ON DWGS. 9 PROVIDE FILTERS AT RETURN AIR OPENINGS OF NEW AND/OR EXISTING UNITS,UPSTREAM OF ANY HEAT EXCHANGER OR COILS PER WSMC 605 2 BLACK COLOR,CONFIRM WITH ARCHITECT PRIOR TO ORDER 10 PROVIDE SEISMIC BRACING PER ACSE 7,UNLESS:UNIT IS WALL MOUNTED OR<20 LBS OR IS RIGID MOUNTED INLINE WITH DUCT(NO FLEX)AND<75 LBS 11 PROVIDE WITH AIREX PROSYSTEM KIT E-FLEX GUARD OR APPROVED EQUAL WHEN EXPOSED TO WEATHER IN COLOR TO MATCH SURROUNDING AREAS(BLACK OR WHITE)COLOR FROM EXTERIOR PENETRATION TO CONDENSING UNIT CONNECTION IN COMPLIANCE WITH(WSECISEC)C403.2.9.1 MODULAR DIFFUSER SCHEDULE 06 24 25 MECHANICAL 30%DO SET UNIT TAG MANUFACTURE CFM N INCHES SIZE FACE SIZE MOUNTING SOUND NC MATERIAL NOTES MECHANICAL 65% SET OUTDOOR UNIT HEAT PUMP SCHEDULE 1D 23 25 MECHANICAL PERMIT ser DT1 TITUS MCD 110 6 6X6 24X24 T-BAR <10 STEEL 1,2,3,4,5 COOLING HEATING CONNSIZE EFFICIENCIES ELECTRICAL DT2 TITUS MCD 230 8 8X8 24X24 T-BAR 17 STEEL 1,2,3,4,5 UNIT MANUFACTURE CAPACITY CAPACITY REFRGNT SUCTION LIQUID SOUND WEIGHT DT3 TFTUS MCD 350 10 10X10 24X24 T-BAR 17 STEEL 1,2,3,4,5 TAG LOCATION SERVES &MODEL BTUH BTUH TYPE IN IN SEER2 HSPF2 MCA MCOP VIPH dBA LBS NOTES MARK DATE DESCRIPTION DT4 TFTUS MCD 500 12 12 X 12 24 X 24 T-BAR 20 STEEL 1,2,3,4,5 ODU-101 CONCRETE PAD OFFICE GOODMAN GZV6SA-181 OA 23200 23200 R-32 3/4 318 19 8.8 16.8 20 208/1 55 122 1,2,3,4,5,6,7 DT5 TFTUS MCD 600 12 14 X 14 24 X24 T-BAR 20 STEEL 1,2,3,4,5 ODU-102 CONCRETE PAD AV EQUIP DAIKIN RXM30WVJU9 31400 R-41 OA 5/8 1/4 17.5 7.5 18.6 20 208/1 56 133 1,2,4,5,6,7,8 PROJECT N0: 2025-021 DT6 TFTUS MCD 880 14 16 X 16 24 X24 T-BAR 26 STEEL 1,2,3,4,5 CAD DWG FILE: M002.DWG DT7 TFTUS MCD 1120 16 18 X 18 24 X24 T-BAR 20 STEEL 1,2,3,4,5 GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION& DRAWN BY: OWN A INSTALL PER MANUFACTURERS REQUIREMENTS A CHK'D BY: DWN GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS 1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTECTION DIRECTION FOR EQUIPMENT AS REQUIRED BY LATEST APPROVED VERISON OF THE NATIONAL ELECTRICAL CODE,PRIOR TO ORDER. PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL PER MANUFACTURERS REQUIREMENTS MANUFACTURER TO PROVIDE SCCR LISTING(5 KAIC MINIMUM OR PER ELECTRICAL CONTRACTOR CALCULATION)INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. COPYRIGHT: 1 RUN OUT SIZE SAME SIZEAS DIFFUSER NECKSIZE,U.N.O.ON DWGS. 2 DISCONNECT SWITCH MAY BE REQUIRED FOR EACH MODULE ON MULTI MODULE UNITS(ELECTRICAL CONTRACTOR TO VERIFY WITH JURISDICTION HAVING AUTHORITY) 2 ALL DIFFUSERS TO HAVE SIDE INLET SHEET METAL CAN PLENUM IF<1 DR STRAIGHT FLEX AVAILABLE FOR TOP INLET 3 R-32 REFRIGERANT,MAXIMUM TOTAL SYSTEM REFRIGERANT LINE LENGTH AND MAXIMUM LIFT TO BE VERIFIED WITH MANUFACTURER-VERIFY ACCEPTABLE REFRIGERANT LINE SIZING, SHEEF TITLE 3 PROVIDE PERFORATED INTERIOR PLATE ON DIFFUSER CAN AND I"SOUNDLININGIFSPACE<-NC-30OR SAT<55°F LENGTHS AND LIFTS WITH MANUFACTURER PROVIDED SIZING PROGRAM SCHEDULES SHEET 4 STANDARD WHITE POWDER COAT 4 PRESSURE TEST REFRIGERANT PIPING AT 600 PSI 5 PROVIDE FRAME 3,LAY-IN TYPE. 5 TERMINATE CONDENSATE DRAIN PIPING INTO BUILDING ROOF DRAINS.CONDENSATE DRAIN PIPING BY PLUMBING CONTRACTOR 6 PROVIDE SURFACE MOUNTING FRAME MODEL TRM-S FOR GRILLE REMOVAL&INSTALLATION IN HARD LID CEILING 6 UNIT TO BE CON FIGURED TO PROVIDE LOW AMBIENT COOLING AT BELOW 24°F&HEATING AT BELOW 24°F 7 WHERE VOLUME DAMPERS ARE NOT ACCESSIBLE,PROVIDE HAND HOLE ACCESS OR YOUNGS REGULATOR WITH CEILING PLATE 7 PROVIDE WITH AIREX PROSYSTEM KIT E-FLEX GUARD OR APPROVED EQUAL WHEN EXPOSED TO WEATHER IN COLOR TO MATCH SURROUNDING AREAS(BLACK OR WHITE)COLOR FROM EXTERIOR OR DURODYNE CABLE OPERATED DAMPERWTH CABLE ROUTED INSIDE DUCT&ADJUSTMENT THROUGH GRILLE FACE 8 REFRIGERANT: R-410A. PROVIDE ADDITIONAL CHARGING OF LINES AS REQUIRED FOR LONG LINE LENGTH APPLICATIONS 1 2 3 4 5 M002 SHEET OF 1 2 3 4 5 G AQUA AIR NEW GAS FURNACE SCHEDULE UNIT AREA BASIS OF COOLING HEATING OSA ESP INDOOR FAN GAS HEAT MBH ELECTRICAL WEIGHT AQUA AIR ENGINEERING DEMO EXIST GAS FURNACE SCHEDULE TAG LOCATION SERVED DESIGN CFM CFM CFM IN WG HP RPM CONTROL INPUT OUTPUT AFLUE MCA MOCP V/PH LBS REMARKS 12400 SE 38TH ST #50014 UNIT AREA BASIS OF SUPPLY GAS HEAT MBH AH-M101 MEZZANINE SANCTUARY WING GOODMAN GRVT960804CNA 1,300 1,300 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 11511 137 1,2,3,4,5,6,7,8 TAG LOCATION SERVED DESIGN CFM INPUT OUTPUT REMARKS AH-M102 MEZZANINE SANCTUARY WING GOODMAN GRVT960804CNA 1,300 1,300 791 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 11511 137 1,2,3,4,5,6,7,8 BELLEVUE, WA 98015 F-1 MECHRM SANCTUARY RHEEM 40 1 AH-M103 MEZZANINE SANCTUARY S CENTER GOODMAN GRVT960804CNA 1,260 1,260 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 11511 137 1,2,3,4,5,6,7,8 www.aqu001rengineering.001Y1 F-2 MECHRM SANCTUARY RHEEM 20 1 AH-M104 MEZZANINE SANCTUARY S CENTER GOODMAN GRVT960804CNA 1,260 1,260 1,014 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 11511 137 1,2,3,4,5,6,7,8 UBI: 605247933 AH-M105 MEZZANINE SANCTUARY S CENTER GOODMAN GRVT960804CNA 1,260 1,260 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 11511 137 1,2,3,4,5,6,7,8 D REMARKS: AH-M106 MEZZANINE SANCTUARY N CENTER GOODMAN GRVT960804CNA 1,260 1,260 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 11511 137 1,2,3,4,5,6,7,8 D 1 DEMO EXISTING FURNACE AH-M107 MEZZANINE SANCTUARY N CENTER GOODMAN GRVT960804CNA 1,260 1,260 1,014 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 11511 137 1,2,3,4,5,6,7,8 CONSULTANTS AH-M108 MEZZANINE SANCTUARY N CENTER GOODMAN GRVT960804CNA 1,260 1,260 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 11511 137 1,2,3,4,5,6,7,8 AH-M109 MEZZANINE SANCTUARY WING GOODMAN GRVT960804CNA 1,300 1,300 1 710 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 11511 137 1,2,3,4,5,6,7,8 AH-M110 MEZZANINE SANCTUARYN WING GOODMAN GRVT960804CNA 1,300 1,300 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 115/1 137 1,2,3,4,5,6,7,8 AH-M111 MEZZANINE FOYER GOODMAN GRVT960804CNA 1,093 1,093 513 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 115/1 137 1,2,3,4,5,6,7,8 AH-M112 MEZZANINE FOYER GOODMAN GRVT960804CNA 1,093 1,093 513 0.60 3/4 1,075 ECM 56.0 54.3 96% 11 15 11511 137 1,2,3,4,5,6,7,8 GENERAL: ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION& INSTALL PER MANUFACTURERS REQUIREMENTS REMARKS: 1 DISCONNECT AS REQUIRED BY ELECTRICAL CONTRACTOR 2 PROVIDE 1"DISPOSABLE FILTERS 3 VERTICAL AIRFLOW CONFIGURATION WITH TOP DISCHARGE 4 AIR SIDE ECONOMIZER CYCLE NOT PROVIDED-PER 2021 WSEC C403.5 EXCEPTION 1A DOAS ERV PROVISION 5 OUTSIDE AIR PROVIDED BY DOAS ERV UNITS.OSA CFM HONED IN BY CALIBRATED BALANCING DAMPER 6 PROVIDE SEVEN DAY PROGRAMMABLE STAND-ALONE THERMOSTAT WITH MICROPROCESSOR CONTROLS PER WSEC C403.4.1 ���LIAtijN 7 HEATING&COOLING FANSIPUMPS SHALL SHUT OFF WHEN THERE IS NO CALL FOR HEATING AND COOLING IN THE ZONE PER WSEC 2021 C403.3.5.2,EXCEPT IF HEATING/COOLING FANS<0.12WICFM Q of wnsyti O,p 8 SMOKE DETECTORS(PROVIDED AND INSTALLED BY ELECTRICAL)IN RETURN AIR UNLESS SINGLE SPACE OR AREA DETECTION SHUTOFF THRU FIRE ALARM OR MUA IF ALL AIR IS EXHAUSTED w �E53350GIs e TRANSFER/ RETURN / EXHAUST AIR GRILLE SCHEDULE SPLIT SYSTEM OUTDOOR CONDENSING UNIT SCHEDULE loS'gm UNIT MANUFACTURE MAX NECK SIZE FACE CONN SIZE EFFICIENCIES ELECTRICAL iolsslA, TAG &MODEL CFM INCHES SIZE MOUNTING MATERIAL NC NOTES UNIT MANUFACTURE ASSOCIATED COOLING CAPACITY MBH REFRGNT SUCTION LIQUID SOUND WEIGHT EC1 TITUS50E-7 500 ---- 24x12 T-BAR STEEL 2,9,10 TAG LOCATION SERVES &MODEL COOLING COIL TOTAL SENSIBLE TYPE IN IN EER2/SEER2 HSPF MCA MCOP VIPH dBA LBS NOTES EC2 TITUS50E-7 1000 ---- 24x24 T-BAR STEEL 2,9,10 PHASE 2 ROCKCREEK CHURCH ARLINGTON EC3 TITUS 7 2000 24x48 T-BAR STEEL 2 g 10 S50E- ---- CU-101 OUTSIDE SANCTUARY WING GOODMAN GXV6SS4810A DX-M101 45500 34125 R-32 718 1/4 8.6/16.0 NIA 31.8 35 208/1 72 169 1,2,3,5,6,7,8,9,10,11C C TITUS3S5OF -15 150 8 8x8 GWB STEEL 1,3,6,7/8,9,10 CU-102 OUTSIDE SANCTUARY WING GOODMAN GXV6SS481 CA DX-M102 45500 34125 R-32 7/8 1/4 8.6/16.0 N/A 31.8 35 208/1 72 169 1,2,3,4,6,7,8,9,10,11 C 730 E HIGHLAND DRIVE G2 TITUS 35ORL AG-1 5 250 10 10x10 GWB STEEL 1,3,6,7/8,9,10 CU-103 OUTSIDE SANCTUARY S CENTER GOODMAN GXV6SS481 CA DX-M103 45500 34125 R-32 7/8 1/4 8.6/16.0 NIA 31.8 35 208/1 72 169 1,2,3,4,6,7,8,9,10,11 ARLINGTON, WA 98223 G3 TITUS 35ORL AG-1 5 375 12 12xl2 GWB STEEL 1,3,6,7/8,9,10 CU-104 OUTSIDE SANCTUARY S CENTER GOODMAN GXV6SS481 CA DX-M104 45500 34125 R-32 7/8 1/4 8.6/16.0 NIA 31.8 35 208/1 72 169 1,2,3,5,6,7,8,9,10,11 MECHANICAL DRAWINGS G4 TITUS 35ORL AG-15 525 14 14 x 14 GWB STEEL 1,3,6,7/8,9,10 CU-105 OUTSIDE SANCTUARY S CENTER GOODMAN GXV6SS481 CA DX-M105 45500 34125 R-32 7/8 1/4 8.6/16.0 NIA 31.8 35 208/1 72 169 1,2,3,5,6,7,8,9,10,11 GS CU-106 OUTSIDE SANCTUARY N CENTER GOODMAN GXV6SS481 OA DX-M106 45500 34125 R-32 7/8 1/4 8.6/16.0 NIA 31.8 35 208/1 72 169 1,2,3,5,6,7,8,9,10,11 OWNER TITUS 35ORL 00 14 16 GWB STEEL 1,3,6,7/8,9,10 G6 TITUS 35ORL AG-15 900 16 18 8X x 18 GWB STEEL 1,3,6,7/8,9,10 CU-107 OUTSIDE SANCTUARY N CENTER GOODMAN GXV6SS4810A DX-M107 45500 34125 R-32 718 1/4 8.6/16.0 NIA 31.8 35 208/1 72 169 1,2,3,5,6,7,8,9,1 Q11 MARYSVILLE FREE METHODIST CHURCH ER G7 TITUS 35ORL AG-1 5 1200 16 24x24 GWB STEEL 1,3,6,7/8,9,10 CU-108 OUTSIDE SANCTUARY NCENT GOODMAN GXV6SS481 CA DX-M108 45500 34125 R-32 7/8 1/4 8.6/16.0 N/A 31.8 35 mm 72 169 1,2,3,4,6,7,8,9,10,11 6715 GROVE ST, G8 TITUS 35ORL AG-15 2400 20 24x48 GWB STEEL 1,3,6,7/8,9,10 CU-109 OUTSIDE SANCTUARY WING GOODMAN GXV6SS481 OA DX-M109 45500 34125 R-32 7/8 1/4 8.6/16.0 NIA 31.8 35 208/1 72 169 1,2,3,5,6,7,8,9,10,11 MARYSVILLE, WA 98270 T1 TITUS 35ORL 150 ---- 8x8 GWB STEEL 3,9,10 CU-110 OUTSIDE SANCTUARY WING GOODMAN GXV6SS481 CA DX-M110 45500 34125 R-32 7/8 1/4 8.6/16.0 NIA 31.8 35 208/1 72 169 1,2,3,4,6,7,8,9,10,11 T2 TITUS 35ORL 250 ---- 10x10 GWB STEEL 3,9,10 CU-111 OUTSIDE FOYER GOODMAN GXV6SS481 DX-M111 45500 34125 R-32 7/8 1/4 8.6/16.0 NIA 31.8 35 208/1 72 169 1,2,3,5,6,7,8,9,10,11 T3 TITUS 35ORL 375 ---- 12x12 GWB STEEL 3,9,10 CU-112 OUTSIDE FOYER GOODMAN GXV6SS481 CA DX-M112 45500 34125 R-32 7/8 1/4 8.6/16.0 NIA 31.8 35 208/1 72 169 1,2,3,5,6,7,8,9,10 11 MECHANICAL CONTRACTOR T4 TITUS 35ORL 525 ---- 14x14 GWB STEEL 3,9,10 T5 TITUS 35ORL 600 ---- 16 x 16 GWB STEEL 3,9,10 GENERAL ALL TRADESTO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIORTO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL T6 TITUS 35ORL 900 ---- 18x18 GWB STEEL 3,9,10 PER MANUFACTURERS REQUIREMENTS ^y U T7 TITUS 35ORL 1200 ---- 24x24 GWB STEEL 3,9,10 1 ELECTRICAL CONTRACTORTO PROVIDE SCCR PROTECTION DIRECTION FOR EQUIPMENTAS REQUIRED BY LATEST APPROVED VERISON OF THE NATIONAL ELECTRICAL CODE,PRIORTO ORDER. T8 TITUS 35ORL 2400 ---- 24 x 48 GWB STEEL 3,9,10 MANUFACTURER TO PROVIDE SCCR LISTING(5 KAIC MINIMUM OR PER ELECTRICAL CONTRACTOR CALCULATION)INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. 2 SPLIT SYSTEM UNITS REQUIRE DISCONNECT AT THE CONDENSING UNIT BY ELECTRICAL CONTRACTOR ^y GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS 3 INVERTER DRIVEN COMPRESSOR,TEST CONDITIONS BASED ON AHRI210/240 PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL PER MANUFACTURERS REQUIREMENTS 4 REFRIGERANT:R-32.UNIT HOLDS 83 OZ.PROVIDE ADDITIONAL CHARGING OF LINES AS REQUIRED FOR LONG LINE LENGTH APPLICATIONS 1 RUNOUT SAMEAS DWG NECK SIZE U.N.O.ON DWG 5 REFRIGERANT:R-32.UNIT HOLDS 100 OZ.PROVIDE ADDITIONAL CHARGING OF LINES AS REQUIRED FOR LONG LINE LENGTH APPLICATIONS 2 CORE ONLY-LAY-IN 6 SINGLE CONDENSING UNIT FOR EACH INDOOR COOLING COIL.REFER TO MFG'S REQUIREMENTS FOR REFRIGERANT PIPE SIZES FOR EACH UNIT CONNECTION-CONFIRM CONTROL WIRE 3 SURFACE MOUNT FRAME GAUGE(14 OR 16 AWG)WITH SUBMITTALS PRIOR TO INSTALLATION TO INDOOR UNIT ^ , 4 CHANNEL FRAME-LAY-IN 7 PROVIDE WITH WIND BAFFLE AND LOW AMBIENT OR HEAD PRESSURE CONTROL SUITABLE FOR LOW AMBIENT COOLING V 5 T-BAR LAY-IN 8 ECONOMIZER EXEMPT PER 2021 WSEC C403.5 EXCEPTION 1A DOAS ERV PROVISION 6 PROVIDE OPPOSED BLADE DAMPER(OBD) 9 PROVIDE VARIABLE SPEED FAN CONTROL FOR SUPPLY FANS>5 TONS(<66%OF DESIGN SPEED AT LOW SPEED SETTING MAXIMUM)PER ENERGY CODE C403.2.11.5 7 PROVIDE DUCTBOARD PLENUM CONNECTION 10 UNIT TO BE CONFIGURED TO PROVIDE LOW AMBIENT COOLING AT BELOW 24'F/HEATING AT BELOW 24°F 8 PROVIDE SHEETMETAL PLENUM/CONNECTION 11 PROVIDE WITH AIREX PROSYSTEM KIT E-FLEX GUARD OR APPROVED EQUAL WHEN EXPOSED TO WEATHER IN COLOR TO MATCH SURROUNDING AREAS(BLACK OR WHITE)COLOR FROM EXTERIOR 9 STANDARD#26 WHITE FINISH PENETRATION TO CONDENSING UNIT CONNECTION IN COMPLIANCE WITH WSEC C403.2.9.1 B 0 10 WHERE VOLUME DAMPERS ARE NOT ACCESSIBLE,PROVIDE HAND HOLE ACCESS OR YOUNGS REGULATORWITH CEILING PLATE OR DURODYNE CABLE OPERATED DAMPER WITH CABLE ROUTED INSIDE DUCT&ADJUSTMENT THROUGH GRILLE FACE �1 DUCT DX COOLING COIL SCHEDULE UNIT BASIS ASSOCIATED FCOND CALIBRATED AIR DAMPER SCHEDULE TAG LOCATION SERVES DESIGNF CONDENSING UNIT SYSTEM CFM TMBH MBH IN WG SUCTSENS ESPIG CO L Q DRAIN TYPE IN BST REMARKS UNIT MANUFACTURE MIN ALLOWED PRESSURE DX-Ml01 MEZZANINE SANCTUARYSWING GOODMAN CHPEA4830C3A CU-101 AH-M101 1,300 45.5 34.1 0.4" 7/8" 1/4" 3/4" HORIZ 78 1,2,3,4,5 O TAG &MODEL LOCATION SERVES SIZE CFM MAXCFM RANGE NOTES DX-M102 MEZZANINE SANCTUARYSWING GOODMAN CHPEA4830C3A CU-102 AH-M102 1,300 45.5 34.1 0.4" 7/8" 1/4" 3/4" HORIZ 78 1,2,3,4,5 CBD1 TROXVFL DUCTWORK OSA/EXH 4" 11 54 0.12"-1.2" 1 DX-M103 MEZZANINE SANCTUARY S CENTER GOODMAN CHPEA4830C3A CU-103 AH-M103 1,300 45.5 34.1 0.4" 7/8" 1/4" 3/4" HORIZ 78 1,2,3,4,5 CBD2 TROXVFL DUCTWORK OSA/EXH 5" 23 89 0.12"-1.2" 2 DX-M104 MEZZANINE SANCTUARY S CENTER GOODMAN CHPEA4830C3A CU-104 AH-M104 1,300 45.5 34.1 0.4" 7/8" 1AH 3/4" HORIZ 78 1,2,3,4,5 CBD3 TROXVFL DUCTWORK OSA/EXH 6" 30 120 0.12"-1.2" 3 DX-M105 MEZZANINE SANCTUARY S CENTER GOODMAN CHPEA4830C3A CU-105 AH-M105 1,300 45.5 34.1 0.4" 7/8" 1/4" 3/4" HORIZ 78 1,2,3,4,5 CBD4 TROXVFL DUCTWORK OSA/EXH 8" 55 257 0.12"-1.2" 4 DX-M106 MEZZANINE SANCTUARY N CENTER GOODMAN CHPEA4830C3A CU-106 AH-M106 1,300 45.5 34.1 0.4" 7/8" 1/4" 314" HORIZ 78 1,2,3,4,5 CBD5 TROXVFL DUCTWORK OSAIEXH 10" 93 372 0.12%1.2" 5 DX-M107 MEZZANINE SANCTUARY N CENTER GOODMAN CHPEA4830C3A CU-107 AH-M107 1,300 45.5 34.1 0.4" 7B" 1AH 3/4" HORIZ 78 1,2,3,4,5 DX-M108 MEZZANINE SANCTUARY SCENTER GOODMAN CHPEA4830C3A CU-108 AH-M108 1,300 45.5 34.1 0.4" 7/8" 1/4" 3/4" HORIZ 78 1,2,3,4,5 GENERAL: WHERECFM'SSHOWNONDRAWINGSDONOTMATCHAVAILABLECFM'SLISTED,INCREASETOTHENEXTHIGHERCFM DX-M109 MEZZANINE SANCTUARYN WING GOODMANCHPEA4830C3A CU-109 AH-M109 1,300 45.5 34.1 0.4" 7/8" 1/4" 3/4" HORIZ 78 1 AVAILABLE CFM VALUES ARE:11,14,19,23,28,34,42,47,54 CFM DX-M110 MEZZANINE SANCTUARY WING GOODMAN CHPEA4830C3A CU-110 AH-M110 1,300 45.5 34.1 0.4" 7/8" 1/4" 3/4" HORIZ 78 1,2,3,4,5 2 AVAILABLE CFM VALUES ARE:23,28,34,40,48,58,67,77,89CFM DX-M111 MEZZANINE FOYER GOODMAN CHPEA4830C3A CU-111 AH-M111 1,300 45.5 34.1 0.4" 7/8" 1/4" 3/4" HORIZ 78 1,2,3,4,5 3 AVAILABLE CFM VALUES ARE:30,50,60,70,83,95,110,120 CFM DX-M112 MEZZANINE FOYER GOODMAN CHPEA4830C3A CU-112 AH-M112 1,300 45.5 34.1 0.4" 7/8" 1/4" 3/4" HORIZ 78 1,2,3,4,5 06 24 25 MECHANICAL 30%DO SET 4 AVAILABLE CFM VALUES ARE:55,75,98,122,149,175,202,230 CFM MECHANICAL 30%DO SET 5 AVAILABLE CFM VALUES ARE:93,126,164,199,235,278,306,338,372 CFM GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION& 10 23 25 MECHANICAL PERMIT SET INSTALL PER MANUFACTURERS REQUIREMENTS 1 HOUSED COIL PACKAGE WITH INTEGRATED SLOPED CONDENSATE PAN,ROUTE CONDENSATE TO CLOSEST INDIRECT DRAIN 2 PROVIDE WITH TXV(THERMAL EXPANSION VALVE) MARK DATE DESCRIPHON LOUVER SCHEDULE 3 PROVIDE WITH DUAL CIRCUITED COIL FOR CAPACITY MODULATION PROJECT NO: 2025-021 UNIT AREA MANUFACTURE MIN FREE WIDETH HIEGHT VELOCITY 4 PROVIDE PLENUM RATED CONDENSATE PUMP(I.E.LITTLE GANT MODEL VCC-20-P),55 GPH AT4 FT.HEAD-1130HP @ 115 VOLTS ROUTED TO NEAREST INDIRECT DRAIN LOCATION M002.DWG TAG LOCATION SERVED &MODEL TYPE CFM AREA SQ-FT INCHES INCHES FPM NOTES 5 HEATING&COOLING FANS/PUMPS SHALL SHUT OFF WHEN THERE IS NO CALL FOR HEATING AND COOLING IN THE ZONE PER WSEC 2018 C403.3.5.2,EXCEPT IF HEATING/COOLING FANS<0.12W/CFM CAD DWG FILE: A L-1 1STFLR DOASEXH GREENHECKESD-435 EXHAUST 1 170 0.51 1 18 12 1 333 1,2 DRAWN BY: OWN CHK'D BY: DWN GENERAL ALLTRADESTO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITHAPPROVED SUBMITTALS COPYRIGHT: PRIORTO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL PER MANUFACTURERS REQUIREMENTS 1 MIN 3/16"FRAME&3"INVERTED CHEVRONS AT 2"ON CENTER,WELDED CONSTRUCTION(MEET SCL CONSTR STD#0751.00) SHEET TM-E 2 SIGHTPROOF BLADES,SCREEN BEHIND IN ROOM TO BE MCNICHOLS 360220041(0.12"MESH MIN&112"HOLE MAX)OR EQUAL SCHEDULES SHEET 1 3 4 5 M003 2 SHEET OF 1 2 3 4 5 G AQUA AIR OUTSIDE AIR CALCULATION RM NUMBER AREA PPL PPLI 1000 SF RM TYPE OSA/PPL OSA/SF LAT>85°F TOTAL OSA CFM EXH/SF TOTAL EXHAUST CFM EQUIPMENT SERVING OSA CFM PROVIDED AQUA AIR ENGINEERING Platform 115 588 41 70 Theaters Stages,studios 10 0.06 No 446.9 0 0.0 12400 SE 38TH ST #50014 Sanctuary 4180 502 120 Public Spaces Places of Religious Worship 5 0.06 No 2758.8 0 0.0 BELLEVUE, WA 98015 Green Room 116 256 8 30 Hotels,motels,resorts Lobbieslpretuncton 7.5 0.06 NO 73.0 0 0.0 Green Room114 371 11 30 Hotels,motels,resorts Lobbies/pretuncton 7.5 0.06 No 105.7 0 0.0 WWW.aquaairenglfleeTlflg.001Y1 Corridor Sanctuary 262 0 0 General Corridors 0 0.06 No 15.7 0 0.0 DOAS-M1,DOAS-M2 3529 UBI: 605247933 Tech 103 142 1 5 Office Space 5 0.06 No 12.1 0 0.0 D Tech 104 106 1 5 Ofice Space 5 0.06 No 9.0 0 0.0 D Family 112B 102 5 50 General Conferencelmeeting 5 0.06 No 31.6 0 0.0 CONSULTANTS Family 112A 187 9 50 General Conference/meeting 5 0.06 No 58.0 0 0.0 Hallway 102 872 0 0 General Corridors 0 0.06 No 52.3 0 0.0 Foyer 101 2549 76 30 Hotels,motels,resorts Lobbieslprefuncton 7.5 0.06 No 726.5 0 0.0 DOAS-M1,DOAS-M2 1026 Entry 100 654 20 30 Hotels,motels,resorts Lobbieslpretuncton 7.5 0.06 No 186.4 0 0.0 Church Office 664 3 5 Ofice Space 5 0.06 No 56.4 0 0.0 1 ERV-1 170 REFRIGERANT VOLUME ANALYSIS PROJECT: ARLINGTON ROCK CREEK CHURCH DATE: 10/21/2025 SYSTEM& SYSTEM COMMON SPACE VOLUMES ACTUAL MAX CODE ADJ MAX COMPLIES ROOM REFRIG CAP AREA CEILING VOLUME LBSPER REFRIG LBS PER CODE LBS WITH SAFETY NAMES (LBS) (SF) (FT) (CF) 1000 CF TYPE 1000 CF PER 1000 CF CODE? FACTOR �APPROACHTO COMPLIANCE(IF REQUIRED) ��VLIAM N CU-101 99.0 4,180 25.0 104,500 0.9 R-32 4.8 4.8 YES 507% Q Of WAsy��t7P THROUGH SANCTUARY113 4,180 25.0 104,500 Q ti TO w CU-112 0 CU-101 99.0 480 9.0 4,320 22.9 R-32 4.8 4.8 NO 21% OK-WITH ADJACENT CONNECTED VOLUME THROUGH 1OX10TRANSFFR GRILLESABOVE 53350 to THROUGH LAUNDRY 110 480 9.0 4,320 TO CONNECTWITH SANCTUARY 0 STER�� CU-112 HALLWAY 108 0 �ss/ONM-��G 0 0 012SIAs CU-111& 16.5 4,075 10.0 40,750 0.4 R-32 4.8 4.8 YES 1185% PHASE 2 ROCKCREEK CHURCH ARLNGTON CU-112 FOYER 101 4,075 10.0 40,750 CU SYSTEM 99.0 289 9.0 2,601 38.1 R-32 4.8 4.8 NO 13% OK-WITH ADJACENT CONNECTED VOLUME THROUGH 1OX10 TRANSFER GRILLES ABOVE 730 E HIGHLAND DRIVEARLNGTO N, WA 98223 FAMILY VIEWING 289 9.0 2,601 TO CONNECTWITH FOYER 0 MECHANICAL DRAWINGS CU SYSTEM 99.0 4,409 10.0 44,090 2.2 R-32 4.8 4.8 YES 214% OWNER FAMILY VIEWING 334 10.0 3,340 MARYSVILLE FREE METHODIST CHURCH FOYER 4,075 10.0 40,750 6715 GROVE ST, o MARYSVILLE, WA 98270 CU SYSTEM 99.0 248 9.0 2,232 44.4 R-32 4.8 4.8 NO 11% OK-WITH ADJACENT CONNECTED VOLUME THROUGH 1OX10 TRANSFER GRILLES ABOVE TECH AREA 248 9.0 2,232 TO CONNECTWITH SANCTUARY MECHANICAL CONTRACTOR 0 CU SYSTEM 99.0 4,428 24.2 106,980 0.9 R-32 4.8 4.8 YES 519% ^y TECH AREA 248 10.0 2,480 SANCTUARY113 4,180 25.0 104,500 0 •^y ODU-101 6.1 1,406 12.2 17,106 0.4 R-32 4.8 4.8 YES 1341% OK-WITH ADJACENT CONNECTED VOLUME THROUGH 1OX10 TRANSFER GRILLES ABOVE OPEN OFFICE 123 418 9.0 3,762 TO CONNECTALLTHE OFFICE AREAS OFFICE 124 71 9.0 639 OFFICE 125 87 9.0 783 OFFICE 126 88 9.0 792 ^ , 0 CO ODU-102 1 5.0 371 15.0 5,565 0.9 R-410s 26.0 26.0 YES 2894% GREEN ROOM 114 371 15.0 5,565 0 B NOTES: B MIN SMALLEST COMMON ROOM VOLUMETO MEET REFRIGERANT VOLUME LIMITS OF THE IMC,PER ASHRAE STANDARD 15-34 COMMON DUCTS OR FIXED PERMANENT OPENINGS BETWEEN ROOMS(TRANSFER GRILLES)ALLOWS COMBINATION OF AJACENT ROOM VOLUMES (�1 O FAN SCHEDULE UNIT MANUFACTURE ARRANGEMENT ESP FAN ELECTRICAL SOUND WEIGHT TAG LOCATION SERVES &MODEL TYPE MOUNTING CFM IN WG RPM BHP HPNV V/PH DAMPER dBA LBS NOTES EF-103 JANITOR JANITOR G'HECK SQ-70 INLINE HUNG 100 1 0.2 1300 0.02 1150 1 120/1 MD 40 28 1,2,3 EF-M101 MEZZANINE RESTROOM G'HECK SQ-100-VG INLINE HUNG 750 1 0.2 1067 0.06 1/4 1 12011 - 46 55 1,2,4,5 GENERAL: ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION& INSTALL PER MANUFACTURERS REQUIREMENTS REMARKS: 1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTECTION DIRECTION FOR EQUIPMENT AS REQUIRED BY LATEST APPROVED VERISON OF THE NATIONAL ELECTRICAL CODE,PRIOR TO ORDER. 06 24 25 MECHANICAL 30%DID SET MANUFACTURER TO PROVIDE SCCR LISTING(5 KAIC MINIMUM OR PER ELECTRICAL CONTRACTOR CALCULATION)INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. MECHANICAL 65%DID SET 2 ELECTRICAL DISCONNECTAND MOTOR STARTER(AS REQUIRED)BYELECTRICAL CONTRACTOR 10 23 25 MECHANICAL PERMIT SET 3 FAN TO OPERATE CONTINUOUSLY 4 FAN TO OPERATE DURING BUILDING OCCUPIED HOURS THROUGH BUILDING EMS BY CONTROLS CONTRACTOR 5 MOTOR TO BE ECM(OR 70%MINIMUM EFFICIENCY)PER ENERGY CODE C405.8 FOR MOTORS GREATER OR EQUAL TO 1/12 HP&LESS THAN 1 HP MARK DATE DESCRIPRON PROJECT NO: 2025-021 CAD DWG FILE: M002.DWG DRAWN BY: OWN q q CHK'D BY: DWN COPYRIGHT: SHEET TIRE SCHEDULES AND CALCULATIONS SHEET 1 2 3 4 5 M004 SHEET - OF 1 2 3 4 5 G AQUA AIR I . I AQUA AIR ENGINEERING 12400 SE 38TH ST #50014 I BELLEVUE, WA 98015 www.aquaairergineering.com J ---------------------II-------- -- ----- — — — ,I UBI: 605247933 I i -1P I I,I I D rrrr III Ip _J1 CONRCTANTS J III loll- I lollIII \' & & rr`-==-==----- ---- --- -------------71 JI I III I II W , I -71 II y II 1 .p '��__�-=_�I ICI C7 C7 I II I I I I DEMO EXISTING MECHANICAL FLOOR REGISTERS / DIFFUSERS 1 III IN SANCTUARY AREA rt== (TYP) ��VLIAM N O OF WASy� 0 _ II i 1�y===------------Jj r� �F II SA�ca - I 53350 ❑ ��`�.�EGISTe G� SS/pNA\L IL JI II Ir__________-11 I'✓ IL 1012SIA, ' -- lIL _�I G �-- � PHASE 2 ROCKCRFFK CHURCH ARLINGTON, --� -- ii -�DEMOEXISTING NATURAL GAS C 730 E HIGHLAND DRIVE II rye rr- h 'I a"N� FURNACES F_� ARLINGTON, WA 98223 i `i IL tJ '� 'li F_2 MECHANICAL DRAWINGS A ��r IF-------- -TI Il NG II a 11'NG OWNER c-J II II II " G p� 'L__�II JI Ilj(�120 �� it�__� � �r—�� r� 5, -- 1113"FLUE UP 3,/4"Nc MARYSVILLE FREE METHODIST CHURCH ,.L �G MB ) 6715 GROVE ST, 11 3"FLU UP II it I ,II MARYSVILLE, WA 98270 2"NG AT 7"W.C.� jlj 2"FLI,(DN _ ;I M,- TO EXISTING GAS FURNACEANDjI C, LGAS WATER LCOIRACfORlL_---_J11HEATERS7 EXIS'fR G \ rAND RELIJ F (VENT OW�� J - IIEXISTING, TURA dL -0 'Iii y,rITHA ALL VV it 1�2"NG AT -- 1/2"NG AT If- --f , r JI FQUIRED.WATEE TIN�iT -1 ICAP. j', j EXISTING GAS �// 7WC 1 I'�°all TII VENTING MAIN IT RETvfA1f0.-- III ^~ .1 I-IJ 11111111111111 FURNACE _ ^•45 MBH Ir_ _ I�II II II o-�JJ 0 III -`II 1 IpS II 11 II 2"NG II - <� I�{j� 'II II ("'120 MBH) 1/2..NG p 'I < I a 1 Ij II II I,(-40 MBH) 1�2NG IL___t_____i�'JI 'I IL_-_- L s -r __ _______________ _______� ___ , , DEMO EXISTING I/2-RATURALTI AT 7'W.C. IL JL V --�', GAS LINE FOR UPSIZED NEW `T-- Ilk 2"NG `-' i V/ GAS LINE.FIELD VERIFY SIZE 11 1 AND LOCATION PRIOR TO J L_________r II (^•190 MBH) ==fi 7"W.C. AT 7"W AT WORK. J FIELD COORDINATE IF II 7"W.C. TO I,7"W.0 TO ___--_ — _ ___ m FIREPLACE II DISHW�,SHE "I /L� �1J EXISTING GAS L30 MBH FIREPLACE IS TO II r _a r�---� If--ll I B A _ V 2"NG REMAIN OR BE DEMO'ED Y I� j ________ i (-370 MBH) L--JI r ' 1 / xs xe xe xc II xs T�xc� I i 2„NG \, -- xFOoER H (-140 �ABH)1 o (^'370 MBH) __ T1 40/MBH � II II=n1� " - __ } DEMO EXISTING 1/2"NATURAL II 11"NG ON!AT Ij Ilj —' Tll GAS LINE FOR UPSIZED NEW EXI$TMGWR-t ___ _ --" I I GAS LINE�FaF10 VERIE;1'SIZE II III r�� 1 AND L 6ATION PRIOR & OVEN 1 11W DEMO EXISTING 2'NATURAL 9 TO 11 j- Ik ssrt� __ ----------------______________J GAS LINE FOR UPSIZED NEW WORK DEMO EXISTING II GAS LINE.FIELD VERIFY SIZE IURALGAS I_ J -wawa' i NATFURNACE , T T -'L AND LOCATION PRIOR TO 11 ,I'I L •' '� -- WORK. / II II IIII II , Ell I I II � II II II II � II • I 1 IP I'IRI `'u�� l II II �' I 2"NG (^'415 MBH) II ❑ p ❑ p ❑ p ❑ Q ❑ I _ fi3T '� i i'i 06 24 25 MECHANICAL 30%DID SET �'Av w.� I i ,_y„I II 1 r- -____- _____- _____- -____- _____- -_____ -____- J MECHANICAL 65%DO SET r ---- _ PII 10 23 25 MECHANICAL PERMIT SET B MARK DALE DESCRIPTION iyi Ir. r✓'� T II \1 rr' PROJECT NO: 2025-021 �i � ^� I� � I�i i CAD DWG FILE: MD201.DWG �7-1 ❑ DRAWN BY: OWN IIII I II \ II I A i illy 2"NG AT A CHK'D BY: DWN �— j' II IIII II 7"W.C. COPYRIGHT: j' 7"W.C. 1I SHEET TITLE ❑a I EXISTING GAS METER. LEVEL 1 MECHANICAL DEMO 1 LEVEL 1 KEY PLAN ® _ (TYP z) I r-a' 1' 3' 5' 10' 15' PLAN ' 1 LEVEL 1 ENLARGED MECHANICAL DEMO PLAN SCALE: $"=1' 1/8"=1.-01, 2 4' 1 2 3 4 5 MD201 SHEET OF 1 2 3 4 5 AQUA AIR j AQUA AIR ENGINEERING 12400 SE 38TH ST #50014 BELLEVUE, WA 98015 www.aquaairengineering.com GDNSCONSULTANTSUBI: 605247933 D D _ 1 I -- ---------------- -1111111111111 -------------------- �r—------� SADDLE PER 2x8 @i6"oc X.&10 C15x50v C15x50 -EC C Wx21 °— Ci5x50 C15x50 at u oo ADDLE PER EX.3x DECKING EX.6x10 LV o n— C15x50 115x50 EX GL 51/5x21 Ci5x5o Ci5x5o 1. 6 �VLIA44 — N Q OF WASyx�O i v C15x50 EX.GL 51/8x21 S w EX 4x10 C15x50 - T' P l o EX.6x10 53350 o HGU HANGE a n o��ss/01 Te G� /1 E C15x50 C15x50 0 GL 51Bx21 " 1011g C15x50 AC15x50 EX.6x10 ..Pb.' LK PHASE 2 ROCKCREEK CHURCH ARLINGTON 730 E HIGHLAND DRIVE _ I _ _ n ARLINGTON, WA 98223 ,� II MECHANICAL DRAWINGS EX BRG.WALL OVER Ili 212x8 � EX.WIBX70 OWNER jlll I;M€N= MARYSVILLE FREE METHODIST CHURCH 6715 GROVE ST, EX. MARYSVILLE, WA 98270 I I I I I III .III I I I I I I I I I III; ;I I MEauNDAE CONTRACTOR EX.410 - I��I . I I I I I I I-II' I =----------_ J Isr,�I_� I •ICI I I I I I V I I I I B a� I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 06_2724 25 MECHANICAL 30%DD SET MECHANICAL 65%DD SET MECHANICAL PERMIT SET 0 N M L K J I H G F E D C B A MARK DATE DESCRIPTION / ' `MEZZANINE LEVEL MECHANICAL DEMO HVAC PLAN PROJECT N0: 2025-021 3/32"=l'-0" CAD DWG FILE: MD202.DwG 1'3'5' 10' 15' 25' DRAWN BY: DWN A SCALE: 3}"=1' A CHK'D BY: DWN 2'4' COPYRIGHT: SHEET TITLE MEZZANINE LEVEL MECHANICAL DEMO PLAN 1 2 3 4 5 MD202 SHEET OF 1 2 3 4 5 / G AQUA AIR j ---------------- l------- ------- ------- ------- -- - ------- AQUA AIR ENGINEERING I I I I I 12400 SE 38TH ST #50014 BELLEVUE, WA 98015 — — — — — — — www.aquaairergineering.com UBI: 605247933 CONSULTANTS I I I D IU-ID2 SM2-215 SM3-270I _ _ __ 120 120 - - -TO MID T _ ODU-,Dz --r- _ — - - TO MID _ r , ------------------ f _ ---- Eli - i 120 --_ __ - i"-T- I r 16X1601IDSL IU-101 3 1DX-M - __I14 r"100 ' ' r.SM3 280 C2 T� 1 m - - - M10 '` Y - _ 110 •�• .� �Ij _� - - .,.;�, '' Y AH M101 &. \ l < - G7-50 104 AH Mll0 & `�� �. A'� < i - __ r _ -_ _ - i �•�I 7� � AH M102 ABOVE WIN ll 86 80 ___ _ _ - _ Y -i - T r - - - - _ , 53350 ( Dow w 10mW ; ---� U _ - _ - _ - - - _ i .! SS/ E� d i- 1 , - � 1 I T \� I DU-101 SM7 75 w ��� C j,\ .� , - r- -, - ` s -` roles es PROVIDER-81NSULATION '� -1 i --r--"i---I---- - -_ i= �� i, CU-106 0 0 oww 1` T __;.'-1 --\I vl PHASE 2 ROCKCREEK CHURCH ARLINGTON ON EXHAUST AIR DUCT �� ( ��I ,�'��d � cu 107 730 E HIGHLAND DRIVE C PER2021 WSEC. . j ( {- - i 'y cu-,o6 C403101.2 PROVIDER-71NSU \, 8 _ --_,y- f ---i"--r-- --T "-�- -' T: 0 ON OUTSIDE AIR DUCT I ---- '------1--:----- -""1 �� C ARLINGTON, WA 98223 PER 2021 WSEC 1411 XHAUST AIR I I aml-loo CU-103 c403.10.1.1 �\ DUCT IUP To 80 ._ I7 u cu-1oa MECHANICAL DRAWINGS ATTIC FI - ' � L CU-105 OWNER 12 TRANSFER GRILLES LOW IN WALL6' A.F.F. FOR _ �1 INSTALL A REQUIRED SET OF TWO MINIMUM 10'X10" - ---, NEAR r v �� EF-10 CU-101 MARYSVILLE FREE METHODIST CHURCH r MEZZANINE CONSTRUCTION NOTES: � - - - - ,-� , (MAX( ) -- 120 Y m cu-1oz 6715 GROVE ST, POSSIBLE REFRIGERANT LEAKAGE. a - II TO D M106, TO DX-M103, SM3-250 •',� .W CU-111 MARYSVILLE, WA 98270 �2 INSTALL A REQUIRED SET OF TWO 10"X10' TRANSFER v� (2 12 II III_ _� &HAH106, H-M1087, DX -M103, AH-A�104,105, 100 - 120 SUPPLY AIR i� EXISTING GRILLES LOW IN WALL 6"A.F.F. FOR POSSIBLE r I LOUVER IIECIIANT,A CONIRACfOR (MAX( P ' \ & AH-M105 DUCT UP TO li REFRIGERANT LEAKAGE. REFRIGERANT PIPING IS NOT TO GO 106 1 L__- THROUGH THE FAMILY VIEWING AREA. REFRIGERANT PIPING TO _ ��2 F-- ,i ATTIC NEAR BE OVER THE TABLE STORAGE AREA. 120 K III 1 MEZZANINE -----` -- �14m-� '�' SM2-170 Oj 100 EX I TINS` Too RA uP=- DR ER O3 INDOOR UNIT TO CENTERED BETWEEN JOISTS IN CEILING 10 f 1 F+ - T212 T LO ^~ U Ali SPACE OTC. ADD SOUND LINED DUCT AT RETURN OPENING 1i C. 01 100 SM3-281 ,"� __ WALL FOR ACOUSTICS. ADD BACK DRAFT DAMPER IN RETURN - -- _ DUCTWORK FOR BEST DECOUPLED OPERATION OF THE BOAS _ -- - - IZ/� - - - -I� 100 1 100 ERV UNIT. - //, •�I 12.7S PP&,,AI LJ ® TRANSFER GRILLE HIGH IN WALL FOR RETURN AIR PATHWAY _ MEZZ NINE ` •• J DU 100 TO ABOVE CEILING IN FOYER. - - - - O5 PROVIDE ACCESS PANEL FOR BOAS ERV LARGE ENOUGH FOR 1 0 12m 12 ®G1220400 lip 1 f RA UP 16 REPLACEMENT AND SERVICE. '� 120 - © COORDINATE T'STAT LOCATION WITH CLIENT, ARCHITECT, AND 10 r & AH M1 y'I� IATJi IZ G.C. �. .�, 18 6^ - 100 O7 RECONFIGURE DRYER EXHAUST ON THE OTHER SIDE OF WALL T2- 05 TO CONNECT TO EXISTING DRYER EXHAUST IN WALL. 80 8 0 18 Q r i -- — — — — 4Z e2 Y Y TD;0330 — r— 0 T� mil hem rW V 10 14 o 0 o 0 r mp'T 06 24 25 MECHANICAL 30%DO SET *- 5 MECHANICAL 657 MIT SEDDIDSET 12 1 10 23 25 MECHANICAL PERT DX­ LJ & AH M 12 MARK DATE DESCRIPTION -- ❑ O ❑I I _ PROJECT N0: 2025-021 CAD DWG FILE: , I I � I Mzo,.owc - I e„ ❑ DRAWN BY: OWN , A A CHO BY: DWN COPYRIGHT: 10 I I I O O O SHEEP TITLE o"Lo ;/`�_ ����--"" LEVEL 1 MECHANICAL HVAC LEVEL, KEY PLAN 1/37,=r-a' 1 LEVEL 1 ENLARGED MECHANICAL HVAC PLAN SCALE: e"_1 3' S1 0' 15' 25 PLAN 1 1/8"=1'-0' 2 4 1 2 3 4 5 M201 SHEET OF 1 2 3 4 5 AQUA AIR AQUA AIR ENGINEERING 12400 SE 38TH ST #50014 BELLEVUE, WA 98015 � - - - - - - - www.aquaalrenglneering.com - ----- ----- UBI: 605247933 CONSULTANTS 1 , — — - - - - - - — - - w-m: — - - 3/'CONDENSATE ON TO �•—•—•� �•—•—•T• CCWTONGUE AT ROCK oou-tat i CARDEN.AVOID DISCHARGE CON PROTEC ON. VFOR SL i I : r q i. .gyp, - -- -- — y - - r r _ i .,. -_- 3/8"RL ____ - _ - - u.,r „g - f -�� a " :'. r n ,-.,�.v �. Y "'a•v - --- ---------------- - - "._ _ .( - �'�!� 'X' CCC i -- -_ {(F� v'',�. RELOCATE EXISTING ® 0cCuU--11o190 pT ,Q•E/ G5ro3ISl3aT5s01 _ GAS WATER HEATERS3/4 COND " " r AS REQUIRED RECONFIGURE FdS/ NA EXISTNG NATURAL Ele Rs� Ep - �T ..." I " GAS AND FLUE VENT 112 ,� — CONNECTIONS. - - 0 0 > - EACH cu-106 PHASE 2 ROCKCRFFK CHURCH ARLINGTON r ` L=Tj T _ -_ CH LINE SET CONSIST$OF 't (TYP 2) _ --- -- -- ----.' ONTO IECEE �T•' •�,�•. .. .!_-_-r ?(12)RL4AND 7/8 .. CU 107 -=tt27iSRsuPTOMEZZANI Riz) y EAGHUNEser 730 E HIGHLAND DRIVE C r CONSISTS OF 1/4' - i �, _ - ___ - - A - OMEZ�iXh7NE _ `,.i � 2 CU-108 F SINK O MEZZANINE AND 7/8"RS LINES � � � CU-103 c � ARLINGTON, WA 98223 (TYP 12) cu-1C4 MECHANICAL DRAWINGS - �� PE4 �L 1"NG (/�NG /' CU-105 OWNER - - - - - - MARYSVILLE FREE METHODIST CHURCH b d b 12 12 I2 CU-101 6715 GROVE ST, au d HII - L cu-n1 MARYSVILLE, WA 98270 -- F, F- :: : _'J - - r 3"FLUE 3"F U /2"NG AT -- `_'III Y 120_M PIPINGT ME(g1ANTA CONTRACTOR ' 1 LEVEL 1 KEY PLAN ® 7"W.C. To SLOPED _ 2"NG A7'�JJ.C. 1/3T=1'-O' EXISTING GAS _ -� T71 O EXISTING PER 2021 i FURNACE 9� �T� ® _ _1 WSFGC - ___ J __I� _ GAS W TER I:J: 2'NG A + + HEAERS _ ® 'V I � _ ' � - -- ---- I I �= I •ICI 2"Nc (�60 BH) 1/2"NG it I "NG UP TO ' (-40 MBE) MEZZANINE - — — — xc — —xc — — CONSTRUCTION NOTES: — — —— — — j i A Oi INSTALL A REQUIRED SET OF TWO 10"X10"TRANSFER _ i GRILLES LOW IN WALL (MAX 6' A.F.F.) FOR POSSIBLE 1 AT 1/2"NIG AT REFRIGERANT LEAKAGE. REFRIGERANT PIPING IS NOT TO GO "W.C. TO 7"W.C� TO THROUGH THE FAMILY VIEWING AREA. REFRIGERANT PIPING To 2-1/2 NG (^• 30 M H) FREPJ.?.CE �� DISHWASHER BE OVER THE TABLE STORAGE AREA. (960 MBH '-4 2 -- (-30 MBH) ' BO RUN REFRIGERANT PIPING THROUGH EXISTING OPENING IN r � 3 WALL (OLD LOUVER). SEAL OPENING AROUND REFRIGERANT (1, 3 M H) -270 B ) PIPING PER 2021 WSEC ENVELOPE REQUIREMENTS AND BRACING FOR REFRIGERANT PIPING. 4 H) I I I I I 1 T 3" G 7"W.C. TO EXIS G RANGE (1, 75 M H)I OVEN O v v I I I I I I I I I I I SI 06 24 25 MECHANICAL 30%DO SET MECHANICAL 65%DO SET 10 23 25 MECHANICAL PERMIT SET -� MARK DATE I DESCRIPTION 7"W-�. PROJECT NO: 2025-021 r ❑ O ❑ CAD DWG w.zot.owc DRAWN BY: OWN ACONNECT NEW 3"NG AT i \, i A CHKD BY: DWN EXISTING METER.LONGEST LINE g 3"NG COPYRIGHT: LENGTH OF 250 FT AT 7'W.C. (1,275 MBE) COORDINATE WITH UTILITY - COMP NY AS REQUIRED. SHEEP TIRE EXISTING GAS _.MET LEVEL 1 MECHANICAL PIPING I I I I I ER %'r����- :,ir\��. --------- r I I (TYP 2) I 1' 3' 5' 10' 15' PLAN 1 LEVEL 1 ENLARGED MECHANICAL PIPING PLAN SCALE: $"=1' 1 2 3 4 5 MP201 SHEEP OF - 1 2 3 4 5 AQUA AIR AQUA AIR ENGINEERING 12400 SE 38TH ST #50014 BELLEVUE, WA 98015 - - - - - - - - - - - - - - www.aquaalrenglneering.com UBI: 605247933 D //\RD 1802� 7 SADDLE PER _ IT) CONSULTANTSS 2x8 @16"oC 200 180 180 190 14x6 C15x 15x50 ° EX.GL 518x21 C15x50 C15x50 80 SUPPLY AIR DUCT SUPPLY AIR DUCT - 200 DUCT 200 SU CT SADDLE PER N RD4-490 X. x EC IN _ 120 120 '/ \ ts0 S 10-4 0 0X10 i60 x_ x -EX. L 1 x21 czmln1 50 C15x50 - RD4-490 SM10-450 160 SUPPLY AIR DUCT 120 co 2DX1D 240 SUPPLY AIR DUCT 240 SUPPLY AIR DUCT �160 SUPPLY AIR DUCT RD4-490 RD4-490 ��VLIAM N 120 120 SM10-450s1I "a Q of wnsy� O 15x C x50 20X10 EX GL 5 1 x21 Q To ts0 60 _ I SM10-450 � 20X10 �� ,Q 53350 p �/ 200 SUPPLY AIR UCT 260 SUPPLY AIR DUCT 260 SUPPLY AIR DUCT 210 SUPPLY AIR DUCT "�cS,EOISTeR��G� S/ONA\-E RDa-490 RD4-490 HGU HANGER OI Ig 20 10 C1 50120 1 15 0 S PDX70 D L 5 118x2l 240 SUPPLY AIR DUCT 160 C15x5 5x50 �-240 SUPPLY AIR DUCT PHASE 2 ROCKCREEK CHURCH ARLINGTON C _ s R D 60 - 0 C 730 E HIGHLAND DRIVE I I 28Te 11 SUPPLY AIR DUCT 280 SUPPLY AIR DUCT 20X7- ARLNGTON, WA 98223 QYP 7) FROMSUPPLY UCT Bos-33 m � MECHANICAL DRAWINGS I BD5-33 TO 80 IN SUPPLY PLEN 0 To 6) BD5-33 4"SOUND LI ED 28"TALL RETURN OWNER ii BD5-33 AIR BOOT E DING FACE OF CONSTRUCTION NOTES: - - - - - ____--__ - - - - - _ ___ - ___ ___ - MARYSVILLE FREE METHODIST CHURCH 1 RETURN OPENING FOR DOAS ERV TO HAVE BACK DRAFT w 120 SO PLY AIR DUCT OPENING TO BE UNDERNEA O N TO TECH AREA -DX_M107 SUPPLY AIR DO T. 6715 GRAVE ST, DAMPER. BDS 33 160 m EX.BRG. _= 240 SUPPLY AIR DUCT 2 2x8 MARYSVILLE, WA 98270 ( MOTORIZED DAMPER CONNECTED OCCUPANCY SENSOR IN _ _ aoo DX M108 ® M105 NORTH EAST SANCTUARY. -I BD5-37 DX-M103 DX-M109 14101 AH M109 AH-M106 DH-M2 DX-M104 O3 MOTORIZED DAMPER CONNECTED OCCUPANCY SENSOR IN AH_M107 AH-M103 rECN4JICAL CONTRACTOR SOUTH EAST SANCTUARY. AH-M104 4 MOTORIZED DAMPER CONNECTED OCCUPANCY SENSOR IN =______= 180 36X20 ON AH-M108 PP Y AIR DUC 16 120 SU O DX-M102 DN TO FA ILY AREA FOYER. DOAS-M1 ^� 180 SUPPLY AH M110 1 -, - 14 3 m , AH-M105 DUL TRETURN AIR DUCT FRO AH 2 L _L AH-M102 a Ill I _ FAMILY^NV AREA._ TO JOIN T 240 EF-M101 DX-M110 - 1 BD5-23 tDO •^y SUPPLY P ENUM. 4 Pna Arnu'TIC_ BD5-27 (TYP 2) 120 e PURPOSES 180 SUPPLY DO C FROM DH-M1 m AH-M101 AH TO JOIN TO 40 20 4 SUPPLY PLENUM. Dx-M11z 605-27 IF BD5-27 DX-M101 (TYP 2) - - - - - - - - B05-23 100 100 RETURN AIR B 5- FAMILY AREA. EXHAUST DUCTWORK O s0 18 LOUO-RET.URN T PnP a nilsnCS ROOF CAP 28'X28"( -1 PURPOSES Ex AIR CHURCH ROOF 26' 2 "(R-B OUTSIDE AIR �I AusT B DU TWORK I DU TWOR AP R IMATE B T A SF R GRILL E FOF LOCATI N OF 120 SUPPLY AIF D CT EXISTING MAN RETURN AIR P TH AY F01 FIELD VERIFYE "CT D T TECH A EA F)Y R. U T T RN AIF DIMENSIONS. - - - - If A OV C 11_ NO Y Y FLEINUM RA FED �I N x 9 I I I 0 Y ..T% I I I ��'• � I I I - � •��P �w I I I r �'��--•mob I I I I I I I 06 24 25 MECHANICAL 30%DO SET •..,� '„`.ate= MECHANICAL 65%DD SET _. 10 23 25 MECHANCAL PERMIT SET I I I I I I MARK DATE OESCRIPIION PROJECT NO: 2025-021 CAD DWG FILE: N202.OWG A DRAWN BY: OWN A DWN COPYRIGHT: 0 MEZZANINE LEVEL ENLARGED MECHANICAL HVAC PLAN SHEET TIRE /� U 178"=1'a' MEZZANINE LEVEL / T )MEZZANINE LEVEL KEY PLAN ,r-,_a 1' 3' s 10' 15' MECHANICAL HVAC PLAN SCALE: $"=1' 2' 4' 1 2 3 4 M20 5 SHEEP OFF - 1 2 3 4 5 AQUA AIR AQUA AIR ENGINEERING 12400 SE 38TH ST #50014 BELLEVUE, WA 98015 - - - - - - — — — — — — — — www.aquaalrenglneering.com UBI: 605247933 D SADDLE PER D CONSULTANTS 2x8 @16"oc C15x50 C15x50 EX.GL 518x21 C15x50 AL C15x50 SADDLE PER N X. x EC IN I C15x50 C15x50 _ _ _EX L 118x2l_ _ C15x50 C15x50 � M a l a v l o l M ��VLIAM N aO F WAs O C15x50 C15x50 _ _EX L 1 x21 H�To C15x50 AL C15x50 y 53350 GISTe ass/ONA1-ECG HGUHANGER rolssles - — — — — — _------ — C15x50 C15x50 L 51 x21 FROMEACH DUCT co)LING C15xso C15xso PHASE 2 ROCKCREEK CHURCH ARLINGTON CCOIL O ITS CORRESP NDINq 8 C 730 E HIGHLAND DRIVE (TYP12) BY P.C.DRAIN R IN ARLINGTON, WA 98223 rA BY P. ROU CONDENSATE OM MECHANICAL DRAWINGS ' 2"NG COOLING COILS TO, All-__❑ AH-M108 (400 MBH) __ FLOOR DRAIN P) OWNER — — FLOOR DRAIN OR SINK — — FacHUNEs coNSls — — MARYSVILLE FREE METHODIST CHURCH A M107 1-1/4""NG BY P.C. ROUE -M106 (240 MBH) 1/4"RLAND78"RSLINES 6715 GROVE ST, CONDENSATE FROM p BRG. ALLO (12)1/4"RLD 2 2x8 MARYSVILLE, WA 98270 - - - - COOLING AI S TO DX M108 .W18 O (12)7/8"RS DJ�I FLOOR DRAIN (TYP) DX—M103 AH M109 DX—M104 MECHANICAL CONTRACTOR AH—M103 2"NG AH—M104 ❑ O1 I 6"B—IVENT (640 MBH) AH—M105 FLUE UP T ^� O (240 MNG ROOF 3EFLUE B-VENT. INSTALL �y U CONSTRUCTION NOTES: AH-M110 (240p MBH) AH-M102 PER MANUFACTURER IOM O1 INSTALL FLUE VENT PER 2021 WSFGC 504.3 WITH PROPER 2-1/2"NG�� (TYR) _ _ 6"B-VENT SLOPE PER 2021 WSFGC. 6" B-VENT UP TO ROOF. {88@ Jv18 — — — — — DX-M110 = � FLUE UP TO •^� Oj ROOF h LONDENSATE FIR DRAIN OR SINK YROUTE I�1 AH-M101 RO -------- 1 8 COOLING COILS T 1"NG DX-M111 FLOOR DRAIN (TO) DX-M112 ( 0 MBH) G DN 960GM IH) o B LO ON OF B EXI M­­ FIEL)WF E%Aa r/l DIM NSI N. YY N X a O Y ..� ... s °u �'��--•mob I I I I I I I I ',"E 0 06 24 25 MECHANICAL 30%DO SET •..,� '„`.ate= MECHANICAL 65%DID SET _. 10 23 25 MECHANICAL PERMIT SET I I I I I MARK DATE OESCRIPIION PROJECT NO: 2025-021 CAD DWG FILE: M202.DWG DRAWN BY: OWN A A I I I I I I CHK'D BY: DWN COPYRIGHT: /� SHEET TRLE / i TMEZZANINELEVELKEYPLAN ® MEZZANINE LEVEL ,r=,_a 1' 3' 5' 10' 15' MECHANICAL PIPING PLAN ' 1 MEZZANINE LEVEL ENLARGED MECHANICAL PIPING PLAN SCALE: $'=1' 2' 4' 1 2 3 4 5 M P202 SHEET 1G OF - 1 2 3 4 5 G AQUA AIR AQUA AIR ENGINEERING 12400 SE 38TH ST #50014 BELLEVUE, WA 98015 www.aquaairengineering.com UBI: 605247933 D D CONSULTANTS \VLIAM N Q �F WASy��OP w 53350 GISTe I I S/ONA\- I I I I rolssles PHASE 2 ROCKCREEK CHURCH ARLINGTON C C 730 E HIGHLAND DRIVE ARLINGTON, WA 98223 coNsrRucnoN NorEs: MECHANICAL DRAWINGS O1 INSTALL FLUE VENT PER 2021 WSFGC 503.6.7 FOR ROOF TERMINATIONS WITH LISTED CAP. OWNER �z ENSURE OSA INTAKE IS MINIMUM ,o FEET AWAY FROM FLUE — — — — — — — — — — — — — MARYSVILLE FREE METHODIST CHURCH VENTS AND EXHAUST. 6715 GRAVE ST, O3 ENSURE THAT FLUE VENT EXHAUST IS MINIMUM 10 FEET MARYSVILLE, WA 98270 AWAY FROM DECORATIVE CROSS FOR FIRE PROTECTION. ' COORDINATE WITH ARCHITECT AND G.C. / / \ MECHANICAL CONTRACTOR p 1 —II 3 Ix P-4 1 1 3 — I - - - - - - • I 2 / 13 I I I I I O _ 06 24 25 MECHANICAL 30%DID SET 0 23 25 MECHANICAL PERMITDSET SET MARK DATE DESCRIPRON PROJECT NO: 2025-021 �1 I' CAD DWG FILE: Mzoa.owc A Q b Q DRAWN BY: OWN A CHK'D BY. DWN COPYRIGHT: O ROOF ENLARGED MECHANICAL HVAC PLAN SHEET TITLE /� U 18"-''a' ROOF MECHANICAL PLAN i ROOF KEY PLAN 1 iar�=r-a' SCALE: $"=1' 2' 4' 1 2 3 4 5 M20 SHEEP I OFF - 1 2 3 4 5 G AQUA AIR AQUA AIR ENGINEERING 12400 SE 38TH ST #50014 BELLEVUE, WA 98015 www.aquaairengineering.com UBI: 605247933 D D CONSULTANTS IA44 N Q OF WASy��OP w ' 53350 p =�161=311 GISTe I2 12 _ S� G� ,oJ2SJA, EXISTING �XISTIN� XISTIN6 PHASE 2 ROCKCREEK CHURCH ARLINGTON C �=���I=�II C 730 E HIGHLAND DRIVE ARLINGTON, WA 98223 EXISTING MECHANICAL DRAWINGS OWNER MARYSVILLE FREE METHODIST CHURCH 6715 GROVE ST, MARYSVILLE, WA 98270 MOUNT CONDENSING UNIT ON STRUCTURAL UNISTRUT RACK. VERIFY MANUFACTURERS MECHANICAL CONTRACTOR RECOMMENDATIONS. (TYR 12) aou-mz �^y EXISTING CU-101 CU-103 CU-106 CU-109 CU-102 CU-104 CU-107 CU-110 coo CU-111 CU-105 CU-10R CU-112 ^V, B ' `EAST U ELEVATION MECHANICAL HVAC PLAN g a� v� 1 3' 5' 10' 15' 25' SCALE: 1"=1' 2 4 06 24 25 MECHANICAL 30%DO SET _27MECHANICAL 65%DO SET 10 23 25 MECHANICAL PERMIT SET MARK DATE 1 DESCRIPTION PROJECT NO: 2025-021 CAD DWG FILE: —.DwG DRAWN BY: OWN A A CHK'D BY: DWN COPYRIGHT: SHEET TNLE MECHANICAL ELEVATIONS SHEET 1 2 3 4 5 M401 SHEET 1? OF - 1 2 3 4 5 G AQUA AIR CALIBRATED BALANCING OUTSIDE AIR DUCT SIZE AS SOUND LINED(2"R-8 MIN) AQUA AIR ENGINEERING DAMPER FOR OSA BEFORE SHOWN ON DRAWINGS.NON - DUCT 2400 SE 38TH ST #500 4 ANY OTHER SUPPLYTAPS ECONOMIZERONLV &WITHIN 2'OF FAN BELLEVUE, WA 98015 DISCHARGE IF POSSIBLE VIBRATION CAULKED JOINT BETWEEN ISOLATORS CAP AND DUCT FOR WWWAgUddll"EFIgIFI22TIIlg.COTYI WEATHER TIGHT SEAL STRAPHANGERS TRAPEZE HANGERS UBI. 6055247933 DAMPER AS SHOWN ROD SIZE FOR LOAD D FLEXIBLE _ BACK DRAFT ON PLANS 1"WIDE 20 GA* LOW PRESSURE DUCT LOW PRESSURE DUCT D CONNECTION DAMPER HANGER STRAP STRAP OR ANGLE CONSULTANTS INLET BELL SHEET METAL FLASHING ------ ___ WITH WELDED CORNER BIRD SCREEN -------i SEAMS 18 60"MAX. EQUALIZING i i MIN GRID ROOFING AND ___ CURB D (BY GC) UNLESS FOOT OF 1.5XD FLASHING STRAP IS PLACED (BY GC) UNDERABOTTOM 11 ACCEPTABLE METHOD AIR HANDLING UNIT OR FILTER � REINFORCEMENT. J� FAN COIL UNIT SECTION ' CEILING i��MIN PREFERRED METHOD NOTES: SCREWS MAY BE OMITTED SIZE BOLT(S)FOR LOAD 1. FIELD COORDINATE EXACT UNIT LOCATION.INSTALL UNIT UP IN BETWEEN IF HANGER LOOPS MEMBERS IF POSSIBLE. 2.PROVIDE SEISMIC BRACING PER IBC.IBC CODE REQUIREMENTS ARE PER SHEET METAL DUCT ROOF OPENING BETWEEN SCREWS SEE PLANS FOR SIZE JOISTS-FIELD SMACNA SEISMIC RESTRAINT MANUAL&ASCE 7 WAS NO Hiy To VERIFY LOCATION �Q�OF CAN SUPPORT 3201bs STRAP WIRE P DECOUPLED DOAS SYSTEM MAXIMUM. w TYPICAL HORIZONTAL FAN COIL ANGLE OR /AIR HANDLING UNIT INSTALLATION n GOOSENECK OUTSIDE AIR INTAKE- DETAIL CHANNEL n ROUND CEILING DIFFUSER DETAIL AEG3350 M501 NOT TO SCALE M501 NOT TO SCALE M5 1 NOT TO SCALE (�S+S,/GI Is e �/ BOTTOM REINFORCEMENT NAB INSULATE BLANKED OFF CLAMP AROUND DUCT LOW PRESSURE DUCT INSULATED OR ��/ /g PORTIONS OF LOUVER TO SAME WITH CAULKED JOINT SOUNDLINED AS SPECIFIED VALUE AS BUILDING EXTERIOR UP 12"MIN.TO HANGER STRAP TO THE BACKDRAFT OR 36"MAX.UNO 20 GA FLASHING (1"WIDE 20 GA) PHASE 2 ROCKCREEK CHURCH ARLINGTON (� MOTORIZED DAMPER,AS WELDED CORNER SEAMS `j APPROPRIATE C 730 E HIGHLAND DRIVE 22 GA.GALV.SHEET METAL 2X2 NAILER ARLINGTON, WA 98223 BLANK-OFF ALL UNUSED 45° 16 GA SHEET METAL SPIN-IN COLLAR WITH MANUAL MECHANICAL DRAWINGS PORTIONS OF LOUVER SEAL MAX CURB OR FIRE AROUND PERIMETER OF TYP. TREATED WOOD IF METAL CURB, VOLUME DAMPER.ORIENT DAMPER BLANK-OFF WITH SILICONE GC TO PROVIDE /j SHAFT PARALLEL TO DUCT AIR OWNER CAULK. LINO (BY GC) INSULATION LOAD RATED FASTENER J FLOW.GC TO PROVIDE ACCESS MARYSVILLE FREE METHODIST CHURCH VERIFY LOCATION LOUVER ROOFING DOOR IF DAMPER IS LOCATED SPRING LOCK 6715 GROVE ST, ON PLANS M (SEE MEMBRANE III IN AN INACCESSIBLE LOCATION. DUCT SIZE VARIES ARCH.DWG) UP ROOF CURB MARYSVILLE, WA 98270 SEE PLAN AND OVER TOP CANT STRIP INSULATED RIGID ROUND DUCT (BY GC) CA(BY T S EXTENSION AS REQUIRED R-7 INSULATION ON OUTSIDE AIR FLEXIBLE DUCT(12'MAXIMUM) MECHANICAL CONTRACTOR DUCTS,UP TO 24"0 SUPPORT FLEXIBLE DUCT UNIT CONNECTION/ RUNS OVER 36"ON 36" HEATER LOCATION MAXIMUM 25"0 TO 50"0 CENTERS. (UNDER 2800 CFM) .� SEAL FLEXIBLE DUCT LINER WITH DRAWBAND I I\\\ - ` •� AND SEAL VAPOR 1 v BARRIER WITH DUCT •Pm TAPE(TYP) SHEET METAL \ DUCT SLOPED PAN AT DS WITH CAULKED JOINTS; TYPICAL AIR DEVICES DRAIN TOWARDS LOUVER.TACK WELD TO ^^ ,, SM CAN AS REQUIRED. SLO E CURBROOF AS BOTTOM AS LOWER DUCT HANGER ATTACHMENTS AND EQUIPMENT SCHEDULE) V ULED(SEE PLANS TO ROOF AS NEEDED ^, TYPICAL INSULATED LOUVER FOR LEVEL INSTALLATION j NOT TO SCALE TYPICAL AIR DEVICE �•Y/ LIGHT DUCT CONNECTION n DUCT ROOF PENETRATION -DETAIL n FLEXIBLE CONNECTION M5 1 NOT TO SCALE M5 1 NOT TO SCALE MM5501 NOT TO SCALE R B B ADJUST 1/3 OF VERTICAL VANESATA45° A FLOOR OR ROOF ABOVE O O'A"MIN FIXED BLADE GRILLE- MOUNT WITH BLADES ANGLED UPWARD Q Q \ TO OBSTRUCT SIGHT LINE THRU GRILLE. ADJUST 2/3 OF \ HANGER STRAP GRI 1 DIAMETER STRAIGHT LLE WIDTH PER PLAN. HORIZONTAL VANES TOP INLET AT A 45° SAME SIZE GRILLE INSIDE ROOM WALL TO DECK RADIUS IX DIA. -BLADES ANGLED UPWARD ALL HANGER WIRES STUD SPACE TO BE CLEAR& 22.5°OR AS NOTED UNOBSTRUCTED BEHIND GRILLE 1/2 L MUST BE VERTICAL L (NOTSPLAYED) A 06 24 25 MECHANICAL 30%DO SET MECHANICAL 65%DO SET 10 23 25 MECHANICAL STUD DEPTH AS REQUIRED FOR PERMIT SET112 L RETURN/TRANSFER AIR CFM&STATIC 11 ADJUST 1/3 OF VERTICAL 's T-BAR CEILING LOSS APPROX.COMBINATION GRILLE HE GHT(STUD SIZE TO 6O BE 1/3 L��1/3 L��1/3 L VANES AT A 22.5°ANGLE A MAX.GRILLE IN 2X4 STUD)OR ADJUST 1/2 OF VERTICAL MARK DATE I DESCRIPTION DECREASE DESIGN AIRFLOW VANES DOWN 22.5°FROM LAY-IN DIFFUSER THROUGH GRILLE BASED ON HEIGHT 14 A A STRAIGHT ONES PROJECT NO: 2025-021 &STUD SIZE COMBINATION SECTION A-A T-BAR CEILING GRID CAD DWG FILE: M50.DWG A +D WALL CAVITY RETURN/TRANSFER DETAIL DOUBLE DEFLECTION DRAWN BY: OWN M501 NOT TO SCALE SIDEWALL REGISTER DETAIL n LAY-IN DIFFUSER W/DUCT DROP A CHK'D BY: DWN 1/2 L 1/2 L �M501 NOT TO SCALE COPYRIGHT: Moot NOT TO SCALE SHEET TITLE DETAILS SHEET 1 2 3 4 5 M5 SHEEP 1,' OF OF - 1 2 3 4 5 G AQUA AIR AQUA AIR ENGINEERING 12400 SE 38TH ST #50014 MINIMUM(4)'g"SUPPORT GRAVITY OR MOTORIZED BELLEVUE, WA 98015 RODS ATTACHED TO STRUCTURE BACKDRAFT DAMPER WWWA uaairen Ineerin .COn1 WITH VIBRATION ISOLATORS q 9 9 (IF SHOWN ON THE PLANS) FINISH UB: 605247933 DSEE FLOOR PLAN FLEXIBLE DUCT GRADE D FOR DUCT CONNECTOR(TYP) SIZE.PROVIDE RETURN DUCT BOARD OR SURROUNDED CONSULTANTS TRANSITION AS SHEET METAL ELBOW COMPACTED BACKFILL 36"OR REQUIRED(TYP) _ TO 95%DENSITY FREE GREATER _L OF LARGE ROCKS, PREFERRED, CLODS,AND DEBRIS ROUTE AS `. REQ'D.FOR COORDINATION W/OTHER OF`d� PROVIDE DETECTION UTILITIES E TAPE ON ALL IN ERROU 6"MIN CONIF ONIF NUO SS PIPE, CEILING— HINGED ACCESS PANEL BELT GUARD a, LIGHT FIXTURE SAND BED 6"BELOW rPEING FAN CABINET WITH ROTATE MOTOR TO SIDE AND ABOVE PE PIPING INTERNAL LINER AS OR BOTTOM POSITION WHEN 24X12 RETURN SPECIFIED INSTALLED ABOVE CEILING GRILLE IAtii N Q OF WASy��O,p IN-LINE FAN NOTE:EXTEND THROAT LENGTH TO PROHIBIT LINE OF NOTE: SIGHT THROUGH GRILLE AND BOOT. UNDISTURBED NATIVE EARTH y 1.PROVIDE SEISMIC BRACING PER SMACNA SEISMIC RESTRAINT MANUAL,IBC AND ASCE 7. 53350 �EGISTeR�� ass/ONM- TYPICAL IN-LINE FAN DETAIL (:j) SOUND LINED RETURN BOOT nBURIED PE PIPING TRENCH DETAIL 10/2S/A, M502 M502 NOT TO SCALE NOT TO SCALE MM5502 NOT TO SCALE �/ PHASE 2 ROCKCREEK CHURCH ARLINGTON C C 730 E HIGHLAND DRIVE ARLINGTON, WA 98223 HALF SCOOP OROBD, MECHANICAL DRAWINGS SEE EQUIPMENT SCHEDULE FOR OWNER CONFIRMATION MARYSVILLE FREE METHODIST CHURCH 6715 GROVE ST, MARYSVILLE, WA 98270 MECHANICAL CONTRACTOR VV 30° 30° " •J� I� V DOUBLE DEFLECTION DIFFUSER(TYP) B (T) ROUND DUCT SIDEWALL DIFFUSER DETAIL MM5502 NOTTOSCALE O 06 24 25 MECHANICAL 30%DO SET _27MECHANICAL 65%DO SET 10 23 25 MECHANICAL PERMIT SET MARK DATE 1 OESCRIPNON PROJECT NO: 2025-021 CAD DWG FILE: M50l.DWG DRAWN BY: OWN A A CHK'D BY: DWN COPYRIGHT: SHEEP TITLE DETAILS SHEET 1 2 3 4 5 M502 SHEEP - OF 14 1 2 3 4 5 G� AQUA AIR AQUA AIR ENGINEERING 12400 SE 38TH ST #50014 BELLEVUE, WA 98015 www.aquaairengineering.com 1-1/4"NG UBI: 605247933 (240 MBH) �� I l AH-M103 RELOCATE EXISTING GAS WATER l CONSULTANTS HEATERS AS REQUIRED. 2"NG l AH-M104 RECONFIGURE EXISTING NATURAL (400 MBH) AH-M105 GAS AND FLUE VENT 2"N G CONNECTIONS. \ (640 MBH) AH-M106 °� l 1-1/4"NG AH-M107 w\ (240 MBH)>- AH-M108 3/4"NG AH-M109 1"NG (-60 MBH) AH-M110 �� AH-M101 � 1"NG 1/2"NG AT 7"W.C.TO IANj N 2-1/2"NG c �\ (-120 MBH) 1/2"NG DISHWASHER WAS" 0, (880 MBH) �\ AH-M111 (-40 MBH) Q �P•= 2"NG AT 7"W.C. \ 1/2"NG 53350 1"NG �I TO EXISTING (-30 MBH)/ � �OSs°iSTeR���� (80 MBH) GAS WATER \ �ON4 HEATERS / AH-M112 GAS SHUTOFF 2"NG �rl VALVE g (-60 MBH) 1"NG 1"NG AT 7"W.C.TO PHASE 2 ROCKCRFFK CHURCH ARLINGTON C 2-1/2"NG 2"NG (--140 MBH) EXISTING RANGE& C 730 F HIGHLAND DRIVE (-130 MBH) OVEN ARLINGTON, WA 98223 (960 MBH) MECHANICAL DRAWINGS € 1/2"NG AT 7"W.C.TO FIREPLACE OWNER 2"NG (-30 MBH) MARYSVILLE FREE METHODIST CHURCH 6715 GROVE ST, (-270 MBH) MARYSVILLE, WA 98270 2-1/2"NG (960 MBH) MEDWrJL CONWACIOR 3"NG 1/2"NG (1,230 MBH) (--45 MBH) � 1/2"NG AT 7"W.C.TO EXISTING GAS B FURNACE \ B �� C/1 3"NG (1,275 MBH) � a O 1"NG AT 7"W.C. a J 06 24 25 MECHANICAL 30%DO SET 0 MECHANICAL 65%DO SET 10 23 25 MECHANICAL PERMIT SET 1 MECHANICAL PERMIT REVISION SEr I� MARK DATE DESCRIPTION PROJECT NO: 2025-021 CONNECT NEW 3"NG AT EXISTING METER. EXISTING GAS METER. ca0 DWG nm M601.Dwc LONGEST LINE LENGTH OF 250 FT AT (TYP 2) DRAWN BY: OWN A 7"W.C.COORDINATE WITH UTILITY 1° 3' 5' 10' 15, 25' A CHK'D BY: DWN COMPANY AS REQUIRED. SCALE: A"=1' COPrRIDrR: 2' 4' SHEET nU o ISOMETRIC GAS PIPING DIAGRAM 1 2 3 4 5 P601 SHEET 15 OF 15