HomeMy WebLinkAbout330 S Stillaguamish Ave_BLD182_2026 CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:330 S Stillaguamish Avenue Permit#:182 Parcel#:31051100102900 Valuation: .OWNER APPLICANT CONTRACTOR Name:PUBLIC HOSPITAL DISTRICT 43 Name:Andgar Corporation Name: Address:330 S STILLAGUAMISH Address:P.O.Box 2708 Address: City,State Zip:ARLINGTON,WA 98223 City,State Zip:Ferndale,WA 98248 City,State Zip: Phone: Phone:360-366-9900 Phone: MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Andgar Corporation Name: Address:P.O.Box 2708 Address: City,State,Zip:Ferndale,WA 98248 City,State,Zip: Phone:360-366-9900 Phone: LIC#:ANDGAC*19102 EXP: 7/11/2015 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial CODE YEAR: 2012 STORIES: CONST.TYPE: DWELLING UNITS: 0 OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arli g n ust be repo o your sales tax return form .and cold i v nfArli ton#3101. Signature Print Nahle Date Released By Date CONDITIONS Adhere to approved plans. Provide 3" concrete pad with seismic bracing attached to the pad. Provide power disconnect. Lines shall be insulated and adhesive tapes are not premitted. See included code section C403.2.8.1 & R101.4.3.1 THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 8/30/2013 Mechanical Permit Base Fee $50.00 8/30/2013 Mechanical Plan Review Fee $200.00 Total Due: S250.00 Total Payment: $0 00 Balance Due: $250.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit Information Date 8/29/2013 Permit Number 182 _____ Project Name Cascade Valley Hospital _ Permit Type Commercial Site Address 330 S Stillaguamish Avenue _ Description Mechanical Valuation 9000.00 Square Feet 0 Status Applied -- Permit Issued Permit Expires Phone 360-366-9900 Tom Bajema Email - — Occupancy Load - - Type of Construction _ Proposed Use Number of Stories 0 - Assigned To Launa Peterson PropeMt Information Owner Information Parcel*31051100102900 PUBLIC HOSPITAL DISTRICT#3 PUBLIC HOSPITAL DISTRICT#3 330 S STILLAGUAMISH 330 S STILLAGUAMISH AVE ARLINGTON,WA 98223 Contractors Contractor Name Primary Contact Phone Email Contractor Type License License# Andgar Corporation Tom Bajema 360-366-9900 CONTRACTOR Labor&Industries ANDGAC'19102 CASCADE VALLEY HOSPITAL () Ext. OWNER rReview Date Type Description Tar et Date Completed Date signed To Status 8/29/2013 Commercial Mechanical Chris Young In Review 8/29/2013 lCommercial Mechanical Launa Peterson In Review r Uploaded Files j Upload File 'I Date _ File Delete 8/29/2013 BLD-182.pdf f 2 � . COMMERCIAL MECHANICAL SUBMITTAL REQUIREMENTS Department of Community Development City of Arlington• 238 N Olympic Ave. •Arlington,WA 98223 • Phone(360)403 3551 • FAX(360)403 3418 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2) SETS OF CONSTRUCTION DRAWINGS,AND ONE(1) SET OF WASHINGTON STATE ENERGY CODE APPLICATIONS. Type of Permit: C) Residential Apartment 0 Commercial Valuation: $9,00000 Project Address: 330 S Stillaguanush Ave Parcel I D#: Lot#: Subdivision: Project Description: Owner: Cascade Valley Hospital Phone Number: Address: 330 S Stillaguamish Ave � City: Arlington State: WA Zip Code: 98223 Contact Person:Mike Andreson uy, ��Ama,, Phone Number: Cell Phone: 360 618 7861 Fax: E-mail: Mich a elA@Cascadevalley.org Address: y� 330 S Stillaguamish Ave City: Arlington State: WA Zip Code: 98223 Please List Quantity of Fixtures Below: FURNACE UP TO 100K BTU CLOTHES DRYER GAS OUTLETS FURNACE OVER 100K FLR FURN INSTALL/RELOCATE SUSPENDED HTR/UNIT HTR\ BOILER UP TO 3 HP APPLIANCE REPAIR APPLIANCE VENT/OTHER BOILER UP TO 4-15 HP TYPE I OR II HOOD VENTILATION EQUIPMENT BOLIER UP TO 16-30 HP AIR AHNDLING UP TO 1 OK CFM VENTILATION FANS BOILER UP TO 31-50 HP AIRHANDLING OVER 10K CFM OTHER VENTILATION SYSTEM BOLIER UP TO 51 HP AND UP INCINERATOR (AST)TANK STORAGE/PIPING ALL OTHER UNITS HEAT PUMP (UST)TANK STORAGE/PIPING Contractor: AndgarcorporaGon Phone Number: 360-366-9900 Address: Po Box 2706 City: Ferndale State: WA Zip Code: 96246 ANDGAC"19102 Expiration: July 2013 Contractors License Number: P • Provide applicable WSEC Worksheet(s)and appliance cut sheet(s)along with application • Provide applicable NFPA or other Reference Standard Material along with application hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in accordance with the laws,rules and regulation of the State of Washington. 8-27-2013 plicants Signature Date � Tom Bajema RECEIVE�"/ Print Applicants Name FOR STAFF USE ONLY S -L OOA Engineering Dept, Permit# Acc d Amount Received Receipt# Date Received 2 COMMERCIAL MECHANICAL SUBMITTAL REQUIREMENTS Department of Community Development City of Arlington• 238 N Olympic Ave. •Arlington,WA 98223 • Phone(360)403 3551 • FAX(360)403 3418 WHEN A MECHANICAL PERMIT IS REQUIRED The City of Arlington requires a mechanical permit before mechanical equipment is installed,altered, or replaced. Examples are installations or alterations of gas piping, replacement of any HVAC equipment, Heat Pumps, Exhaust Systems, Paint Booths, Above-ground and Under-ground tanks with piping, etc. The City of Arlington does not require a permit to replace an existing gas clothes dryer, stovetop ranges, ovens, or gas log if there is no gas piping installed or altered. MECHANICAL PLAN REVIEW IS REQUIRED FOR THE FOLLOWING PROJECTS 1. New Commercial Buildings. 5. All hoods (Type I and 11). 2. Complete HVAC systems and AC units, heat 6. All Commercial gas piping. pumps, rooftop units or exhaust fans. 7. Any penetrations of fire resistive construction 3. Relocation of 10 or more diffusers. 8. All spray booths 4. Addition of fan coil units. SUBMIT TWO(2)COPIES OF THE FOLLOWING FOR MECHANICAL PLAN REVIEW: ❑✓ Mechanical plans or drawings. (Minimum plan size is 18"X 24" scale, %" scale for details.) ❑ Reflected ceiling plan showing and identifying ductwork, equipment, piping, supply diffusers, return air grilles and fire dampers. ❑ Roof plan showing equipment, ductwork, vents, roof access and equipment screening. ❑✓ List of equipment and schedule. ❑ Engineered structural gravity and/or lateral force calculations for ALL rooftop units. ✓❑ A Commissioning Plan shall be submitted with the following: A detailed explanation of the original design intent Equipment and systems to be tested, including the extent of tests Functions to be tested, i.e. calibration, economizers, etc. Conditions under which test shall be performed, i.e.winter or summer design,full outside air, etc. Measureable criteria for acceptable performance ✓❑ Washington State Non-Residential Energy Code Forms. Structural Information: Please note that engineered structural gravity loads calculations are required for all rooftop units. If the unit is 440 lbs. or larger engineered structural lateral force calculations are also required. All Natural Gas Fuel Gas Piping is covered under the 2009 International Fuel Gas Code. Liquefied Petroleum Gas installations are covered by NFPA 54 (National Fuel Gas Code) and NFPA 58 (Liquefied Petroleum Gas Code). Gas water heater replacements require a permit and are regulated by the Uniform Plumbing Code RECEIVED AUG 2 9 2013 COA Engineering Dept. 1 2012 Washinaton State Ener Code Qom fiance Forms for Commercial, GrouQ R1 and>3 story R2 and R3 Mechanical Summary MECH- 2012 Washington State Energy Code Compliance Forms for Commercial.Group R1,and>3 story R2&R3 Revised June 2013 Project Info Project Address 0 S/1 A'x r1 v,"r� 1 u e— Date J /<24 L_ I )4/> !2 F_ Z 3 For Building Dept.Use Applicant Name: Applicant Address: o p.o. Be; 217,4 Applicant Phone: & _ a— - c c/G Project Description /h,5t,,,/j 3 00 0-?0 i3 j—U cac 11 171 u ;f , (,%Uc11'�� Briefly describe mechanical system type and features. (� f Includes Plans Include documentation requiring compliance with commissioning provisions per Section C408. �imple System Dornplex System i�ystems Analysis Compliance Option Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans,fill in the required information below. Cooling Equipment Schedule Equip. Equip Capacity` OSACFM SEER Econmizer Heat ID Type Brand Name' Model No.' Btu/h or Econo? or EER IPLV3 Option or Recovery Exception6 Y/N lhcOLLuqq;> �rf5<< P /� i AA430"k ,I�g�p 300eO , PS, 5 2 AJ :ur�la j r Al Y-A.3.0 Jui/P 7 Heating Equipment Schedule Equip. Equip Capacity` OSA cfm Heat ID Type Brand Name' Model No.' Btu/h or Econo? Input Btuh Output Btuh Efficiency° Recovery Y/N Fan E ui went Schedule Equip. Equip ID Type Brand Name' Model No.' CFM SP' HP/BHP Flow Controls Location of Service Service Water Heating Equipment Schedule Equip. Equip Input Sub- ID Type Brand Name' Model No.' Capacity Category EF7 Location of Service I If available. 2 As tested according to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. 4 COP,HSPF,Combustion L€jgtee-c` QJAF as applicable. 5 Flow control types:variable air volume(VAV),constant volume(CV),or variable speed(VS). 6 Economizer e'xd!?�itiof n3 � �r Simple Svstems C403.3.1 or Complex Svstems C403.4.1. 7 Efficiencv Factor per Table C404.2. COA Engineering Lepf. � - � � 2- Mechanical Permit Plans Checklist - Page of 2012 Washington State Energy Code Compliance Forms for Commereial,Group R1,and>3 story R2&R3 Revised June 201 3 Project Address ,"'C) 5 Date 3 LR '(-1 C Yr'f l 1 The following information is necessary to check a rn hamcal permit application for commercial provision compliance with the 2012 WSEC. NOTE:Define print area in Excel prior to printing MECH-CHK pages. Applicability Location on Building Department (yes,no.na) Code Section Code Provision Information Required Plans Notes GENERAL PROVISIONS Equipment Sizing&Performance V eS C403.2.1 Load calculations Load calculations performed perASHRAE Std 183 or equivalent per Chapter 3 L C403.2.2 Equipment and system sizing Output capacity of heating and cooling equipment and systems do not exceed r/C Cj calculated loads.note exceptions taken N C403.2.5 Minimum ventilation Ventilation(natural or mechanical)provided per IMC;indicate mechanical ventilation is capable of being reduced to minimum requirement per IMC C403.2.3& iProvide equipment schedules or complete MECH-SUM tables with type, EE C403.2.3.2& Equipment minimum efficiency capacity,efficiency,test standard(or other efficiency source)for all mechanical �J C403.2.12.1 equipment Ja df i t°7 C403.2.13 Electric motor efficiency Provide equipment schedule with hp,rpm,efficiency for all motors;note except PS C403.2.10 Fan power limitation Fan system motor hp or bhp does not exceed limits per Table C403.2.10.1(1) Scu»l�r/7t C403.2.1013 I e5 &C403.2.13 Fractional hp fan motors Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency req. (Maximum air cooled chiller y)Ca C403.2.3 ,capacity Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit C403.2.1 Non-standard water-cooled Full-load and NPLV values for water-cooled centrifugal chiller adjusted for non- chillers standard operational conditions C403.2.12.1.2 Centrifugal fan cooling towers Large capacity cooling towers with centrifugal fan(s)meet efficiency t� requirements for axial fan open circuit cooling towers n C403.2.3 heaters Forced air fumace and unit Indicate intermittent ignition or IID,flue/draft damper&jacket loss C403.2.3.3 Packaged electric List equipment required to be heat pumps on schedule Q� heatina/cooling en inment C403.2.3.4 Humidification Indicate method of humidification(note requirements for systems with n economizer) HVAC System Controls&Criteria C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans,including perimeter V C 5 systems t� C403.2.4.1.1 Iheatt pump supplementary Indicate staged heating(compression/supplemental)&outdoor lock-out temp C403.2.4.2 Setpoint overlap(deadband) Indicate 5°F deadband minimum for systems controlling both heating&cooling n C403.2.4.3 Automatic setback and Indicate zone t-stat controls with required automatic setback&manual override shutdoC403.2.4.3.3 Automatic(optimum)start Indicate system controls that adjust equip start time to match load conditions C402.4.5.2& Indicate location of OSA,exhaust,relief and return air dampers;include AMCA C403.2.4.4 Dampers gated leakage and control type(motorized or gravity:note exceptions taken) C403.2.11 Heaflng outside a building 'Indicate radiant heat system and occupancy controls n C.,i_ C403.2.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions G4ouiloment C403.2.4.6 Combustionheating Indicate modulating or staged control A C403.2.4.7 Group R1 hotel/motel systems Indicate method for guest room automatic setback&set-up of 5°F minimum r1 G1 C403.2.4.8/9 syst,, 2IR3 dwelling unit Indicate 5-2 setback periods: exceptions tfons tokens in primary spaces with minimum of two C403.2.5.1 Demand controlled ventilation Indicate high-occupancy spaces and systems requiring DCV C403.2.5.2 Occupancy sensors Indicate spaces requiring occupancy-based system control and method;or alternate means provided to automatically reduce OSA when DartialIv occupied Enclosed loading Indicate enclosed loading dock and enclosed parking garage ventilation system n eL C403.2.5.3 dcck/parking garage activation and control method ventilation C403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make-up air,indicate make-up air source and n GL conditioning method C403.2.5.4.2 Laboratory exhaust systems Iindicate lab exhaust systems requiring heat recovery,method&efficiency;or alternative method taken(VAV,semi-conditioned makeup,or CERM calculation) C403.2.6.1 Energysecovery- ventilation indicate ventilation systems requiring ER,method&efficiency;note exceptions system n Cv� C403.2.6.2 Energy systems recovery-condensate indicate on-site steam heating systems requiring energy recovery p) C403.2.6.3 Energysecovery-condenser Indicate remote refrig.condensers requiring ER and use of captured energy Mechanical Permit Plans Checklist - Page of 2012 Washington State Energy Code Compliance Forms for Commercial.Group R1,and>3 story R2&R3 Revised June 2013 Project Address Date _ _ The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE:Define print area in Excel prior to printing MECH-CHK pages. Applicability Code Section Code Provision Information Required Location on Building Department (yes,no,na) I I Plans Notes GENERAL PROVISIONS,CONTINUED HVAC System Controls&Criteria,Continued C403.2.12 Variable flow control- indicate fan&pump motors requiring VF control&method(VSD or equiv {1 rti fans/Dumps controls) n C403.2.12.1 towers arile flow control-cooling Indicate cooling tower fans requiring variable flow control and method C403.2.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and cooling n C demand:or exception taken C403.2.12.2 Single zone AC systems Indicate method of cooling demand-based fan control for sys.>110,000 btuh C4 C403.2.4.10 DDC system capabilities Identify all DDC system input/output control points and indicate capability for 11 trendina and demand response set pint adiustment Ducting Systems C403.2.7.1& Duct construction Indicate all ductwork constructed and sealed per IMC,C402 leakage n Pik C403.2.7.3 requirements and IBC vapor retarder requirements 0403.2.7.3.1=Duct pressure classifications Identify location of low,medium and high pressure ductwork on plans C403.2.7.3.3 High pressure duct leakage Indicate high pressure duct leakage testing requirements on plans;provide test J1 Cn test results to iurisdiction when completed y� Ci, C403.2.7.1/2 Duct insulation Indicate R-value of insulation on ductwork Piping Systems A-( C403.2.8 Piping insulation Indicate R-value of insulation on piping C403.2.8.1 'Piping insulation exposed to Indicate method of protection from damage/degradation n weather SIMPLE SYSTEMS Qualifying Systems t`'S C403.3 Qualifying single zone Verify unitary or packaged equipment does not exceed capacity limits,does not systems have active humidifcation or simultaneous heating/cooling AC403.3 Qualifying 2-pipe heating 'Verify 2-pipe heating-only system does not exceed capacity limits systems yj r1 C403.3.2 Hydronic system controls iRefer to Complex Systems Section C403.4.3 Simple System Economizers q C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls;note in equip sched. C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100%OSA,or exception �.\ C403.3.1.1.3 Air controls Indicate high limit Indicate high limit shut-off control method per Table C403.3.1.1.3(2) C403.1.1.2 Integrated air economizer Indicate capability for partial air economizer operation for systems with capacity y1 Bl operation >65.000 btuh C403.3.1 Air economizer exceptions Indicate eligible exception(s)taken and provisions to comply with exception(s) COMPLEX SYSTEMS Complex System Economizers AG;l C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls;note in equip sched. C403.4.1.4 'Economizer heating system Verify control method of HVAC systems with economizers does not increase n r� impact building heating energy usage during normal operation !�. C403.4.1.3 Integrated economizer Indicate capability for partial economizer operation for air or water econo operation s stems Moved Water economizer capacity Indicate water econo capable of 100%cooling capacity at 50°F db/45°F wb �\ DSA I^ C403.4.1.2 Water economizer maximum Indicate precooling coils and heat exchangers do not exceed pressure drop limit Y` pressure drop h C C403.3.1 Air economizer exceptions 'Indicate eligible exception(s)taken and provisions to comply with exception(s) • • 2012 Washington State energy Code Comptanee Form,for Cammoroal,Group R1,and>3 story R2&R3 Revised June 2013 Project Address Cate Tne following information is necessary to check a mechanical permit apphcauon for commercial provision compliance with the 2012 WSEC. NOTE!Define print area In Excel prior to printingMECH-CHK pages. Applicability Code Section Code Provision Information Required Location on Building Department (yes.no,na) Plans Notes COMPLEX SYSTEMS,CONTINUED Specific System Requirements C403.4.2& Variable flow control-fans Indicate fans requiring variable flow control and method d7 CL C403.2.12 C403.4.2.1 '/AV fan static pressure Indicate sensor locations on plans;include at least one sensor per major duct sensors branch C403.4.2.2 VAV fan static pressure Indicate fan system static pressure selpoint based on zone requiring most selpoint pressure C403.4.5 VAV systems serving multi- Indicate supply air systems serving multiple zones that are required to be VAV, zones method of primary air control,and zones served;note exceptions taken C403.4.5.4 VAV system supply air reset Indicate controls that-automatically reset supply air temp in response to loads C403.4 Large capacity cooling Indicate method of multi-stage or variable control for building cooling system systems capacity>300 Ions C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method C403.4.3 Large rapacity boiler systems Indicate multi-stage or modulating burner for single boilers>500,000 btuh C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers C403.4.3.5 Chiller/boiler plant pump Indicate capability to automatically reduce overall plant flow and shut-off flow isolation through chillers&boilers when not in use C403.4.2& Variable flow control-pumps Indicate pumps requiring variable flow control&method C403.4.3.6 C403.2.12.1 Variable flow control-cooling Indicate cooling lower fans requiring variable flow control and method &C403.4.4 towers C403.4.3.4 Hydronic system part load Indicatealu,a he &chilled water systems have the capability to automatically controls reset supply water temp AND reduce flow by z 50%for systems>300.000 btuh C403A.3.2 Two-pipe changeover Indicate deadband,heating/cooling mode scheduling and changeover systems temperature ranee C403.4.3.3.1 Water loop heat pump- Indicate capability of central equipment to provide min.20°F water supply temp deadband deadband between heat rejection and heat addition modes C403.4.3.3 Water loop heat pump-heat Provide heat exchanger that separates cooling tower and heat pump loop in refection Climate Zone 5 C403.4.3.3.3 Water loop heat pump- Indicate 2-way isolation valve on each heat pump and variable flow control for isolation systems with total Dump powei 10 hD I( C403.4.6 Condenser water heat Indicate system provided to pre-heat service water and efficiency recovery C403.5 Cooler/freezer-anti-sweat '.Indicate w/sf&control method for walk-in cooler/freezer door and-sweat heaters heaters C403.5/6 'Cooler/freezer-evaporator Indicate motor type for evaporator and condenser fans<1 hp and wridenser fans SERVICE WATER HEATING Service Water Systems d� C404.2 Water-heating equip min. Provide equipment schedule or complete MECH-SUM table with type,capacity, efficiencv afficiencv,test standard for other efficiencv source) C404.3 Temperature controls Indicate temperature controls have required selpoint capability C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply&discharge 1 C404.5 Insulation underwater heater Indicate R-10 insulation under tank C404.6 Service water piping Indicate R-value of insulation on piping;note exceptions taken ,insulation C404.7/6 'Circulation systems and heat Indicate shut-off capability based on occupancy and periods of limited demand lIrace shutoff C404.9 Group R-2 service hot water Indicate method of usage metering for dwell.units served by central HW system meters Pools&In-Ground Permanently Installed Spas C404.10.1 (Pool heating equip min. Provide equipment schedule or complete MECH-SUM table with type,capacity, j1 e4 efficiency efficiency,test standard(or other eff.source);heat pump heaters z 4 COP C404.10.1/2 IPool heater on/off controls Indicate automatic on/of control based on scheduling&accessible on/off switch on heater that operates independent of thermostat setting;or exception taken C404.10.3 IPool covers Indicate vapor retardant cover and insulation rating as required C404.10.3 (Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to>90OF C404.10A (Heat recovery Indicate method,exhaust air temperature reduction and recovered energy use MITSUBISHI AW'W ELECTRIC P-SERIES COOLING & HEATING 30,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM Job Name: C,5(,Jc (1,411,V / s vj,, Location, Date: Purchaser: Engineer: Submitted to: For INRI eference ❑Approval ❑Construction System Designation: ,,J j u,A Schedule No.: n11 rnlnm; rq. Indoor Unit:PKA•A301<5 E If i h I Outdoor Unit PUY-A30NHA4(BS) GENERAL FEATURES •Y •Wall-mounted indoor unit for residential and commercial applications •Shiny-white-exterior plastic:compact design •Quiet operation—both indoor and outdoor units • function—integrated diagnostics Limited w CITY O F A R L I N&ON •Limited warranty:five years parts and seven years compressors UNIT OPTION BUILDiN ITMENT ❑ Standard Model.......................................... . .PUY-A30NHA4 A 7n ❑ Sea Coast(BS) Model..............................PUY-A30NHA4-BS OPTIONAL ACCESSORIES -- - Indoor Unit ❑ Mini Condensate Pump(S11730-230,230V) ❑ L-Connector Pipe(PAC-SC84P1;for left side unit piping installation) DATE — — �- Outdoor Unit 0 HA41GES AUTHORIZED ❑ Drain Pan(PAC-SG63DP) UNLESS APPROVIED BY THE ❑ Drain Socket(PAC SG61 DS) BUILDING I N SPECTI�fi ❑ Three-pole Disconnect Switch(TAZ-MS303) ❑ Wind Baffle(WB-PA2) ❑ Air Outlet Guide(PAC-SG59SG) ❑ Mounting Base(OSD-400N) ❑ Mounting Pad(ULTRILITE2) ❑ Wall-mounting Brackets(CWM61) RECEIVED Controller Options ❑ Wireless Wall-mounted Remote Controller Kit(MHK1)' ❑ Portable Controller(MCCH1)` AUG 29 201;; ❑ Outdoor Air Sensor(MOS1)' 'See Submittal for information on each option • Wired Wall-mounted Controller(PAR-21 MAAU) • M-NET Adapter(PAC-SF81 MA) COA Engil teering Dep- CN51 Connector for Multiple Remote Controller Adapters/Duct Fan Controller(PAC-725AD) Q CN32 Connector for Remote On/Off(PAC-715AD) ha-)— U ❑ Remote Temperature Sensor(PAC-SE41TS) ❑ Remote Operation Adapter-Display and On/Off(PAC-SF40RM) ❑ Hand-held Wireless Remote Controller(PAR-FL32MA:req.PAR-FA32MA-E) ❑ Wireless Signal Receiver Module(PAR-FA32MA-E) ❑ Lockdown Bracket for Hand-held Controller(RCMKPI CB) I ` I ER R ❑ Control/Service Tool(PAC-SK52ST) SEACOAST PROTECTION • External Outer Panel:Phosphate coating+Acrylic-Enamel coating • Fan Motor Support:Epoxy resin coating(at edge face) • Separator Assembly;Valve Bed:Epoxy resin coating(at edge face) • Screws(used outer side):Zinc nickel coating 5pm+ Polyvinylidene chloride coating "Blue Fin"treatment is an anticorrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. 0 2013 Mitsubishi Electric US,Inc. ■ PKA-A30KA4 ■ Cooling' Indoor Unit Rated Capacity... .......................30,000 Btu/h MCA.............................................. 1 A Minimum Capacity . ...........................12,000 Btu/h Blower Motor(ECM) ........................... 0.36 F.L A. SEER......................................15.5 Btu/h/W Blower Motor Output.............., ............. .. ...56 W EER ....................................... 7.3 Btu/h/W Airflow(Lo-Mid-Hi) .......... . . . .635-705-775 Dry CFM Total Input. .. ..................... ..............4,130 W 570-635-700 Wet CFM Air Filter ................... .. Polypropylene Honeycomb •Rating Conditions per AHRI Standard Sound Pressure Level(Lo-Mid-Hi)....................39-42-45 dB(A) 9 P SHF ............................................. 0.70 Cooling Indoor.800 F(2r C)DB/670 F(190 C)WB Moisture Removal................................ 8.1 pt./h Cooling Outdoor.950 F(350 C)DB/750 F(240 C)WB DIMENSIONS UNIT INCHES/MM Electrical Requirements W 46-1/16/1 170 Power Supply................ .. .208/230V,1-Phase,60 Hz D 11-5/8/295 Recommended Fuse/Breaker Size. .. . .30 A H 14-318/365 Voltage Weight..........:..... . .. . ... . . ...........46 lbs./21 kg Indoor-Outdoor S1-S2 ............ . . AC 208/230V External Finish........ . Munsell No.1.OY 9.2/0.2 Indoor-Outdoor S2-S3 ............ . . . . . . .. .. .....DC±24V Field Drainpipe Size O.D . ...........5/8"/16 mm OPERATING CONDITIONS Indoor Intake Air Outdoor Intake Air Outdoor Unit Temp. Temp. Compressor.................. DC Inverter-driven Twin Rotary MCA. .......................................... .25 A Maximum 95°F(35°C)DB 1150 F(46°C)DB MOCP............................................ 40 A Cooling 71°F 22°C WB Fan Motor(ECM).............................. 0.75 F.L.A. Minimum 67°F(19'C)DB 0°F'"(A 8°C)DB Sound Pressure Level 570 F 140 Cl WB Cooling ........... ......... . 48 dB(A) With optional wind baffle accessory installed.If not installed, the minimum temperature will be 230 F(-5°C)DB. DIMENSIONS INCHES/MM W 37-3/8/950 D 13+1-3116/330+30 H 37-1/8/943 Weight ...... ................... .. .......163 lbs./74 kg External Finish . ...... ........... . . .Munsell No.3Y 7.8/1.1 Refrigerant Type........ .. . ........ ............. R41OA Refrigerant Pipe Size O.D. Gas Side... . .......................... 5/8"/15.88 mm Liquid Side.. .............................3/8"19.52 mm Max.Refrigerant Pipe Length.....................165'/50 m Max.Refrigerant Pipe Height Difference ............100'/30 m Connection Method ........ . .........Flared Notes: Specifications are subject to change without notice. 0 2013 Mitsubishi Electric US,Inc. DIMENSIONS: Top side Unit:inch(mm) Zz Q r`0 — D_ C Left side Front side R)ght side sln,nt ocam Knockout hole rar,r z-.t ■ i C \ 45 �-I 2-79M 33-2132 9-10.41 11 SB(295) •3/I6(5) .e6-sn6(117G) Knockout hole for Front side(Grille open) eraamlam n y pipng D er unp Recetver i -- — Terminal docK for Otttloor unt Terminal block(or power supply(option) Terminal hlockfor FJter rtodc l \ +e1110t.cOnODik�r(OrN PKA.bKA mWC7]! -- Emergenq opcac n swdth g t-3ri6 4-27A2 omen Ihe3 3 N 1 17-15,32(444)fGas vice (123) 2.1962 CEM tl a 6-1116(15-e 231l32 583 Oran nose 5.90(c1a) Under side F)png connection PFU a) Refrigerant pipe:318 O.D.(09 52) UO M pipe)Flared connection,318F m Refrigerantpipe:51HOD(01588) ieeve Gas pipe Flared connaction:5RF a 'F1eldsuodled) Through dole1 Drol0osel5,0('016)00 02-15/16(9675) j62�Os"-�3-5132 vane auto) LOtwer(manual) HnOckOUt tt01e .. for tower Mo4na/ a Certa meslremert hde o3A2(025) 4t011A2(ts9)Bdthde c Knockout hde for piping ( ) 3 Q Q c B eve_ TaRr tde;FW `a't "' d C _ Indoor un!t oualne c B A - - Tmo� •-� sle psi o ,a fu 31J32OM 1 65r w t,>» 7nefe75) 3o2o�a vile IV) ]-9r16 nvn 817r32(n7)� 2-9/16(65) a (tun 13a2(87) 2-9/16(65) 9-1712044 _— 6ytfp3�1� OR tt-112 cam) t7+YY2 v4daIT) r"Lo Knockout hole forRequired space pndoor tnlA eaipde foryt0rlar t Mf ntl Al L Wall hole for right rear piping / AiMM Mtl.2 5051 Mln.2-270(724) Mm.8-21A2(2* w l: Z Specifications are subject to change without notice. ©2013 Mitsubishi Electric US,Inc. DIMENSIONS: 1 ' 1 I Unit:mm(inch) 0 — � 3 _ s_ .LVit9f,lt. Q€Q€ a^p 8t aYiB7t>U!C aSR'1+it Z � a429D Ot9 � � E ik�tA7> •LUCL>[5 �i � acsi-t,se � b� � LL 8 etRf•t>t a s � i � b g at,occ .suet>a .Luau //�� .ars•et>u+ .ns�,efi �tms>fe�f \ � atit•IA cet R a z � 0 o m �rf+u LUW �,� 00000 qm5 a % OD cEo $' 181 o00 Nye d E tp $ie A x t � Z 0 q WLU Cn p� W o AfnY>< KL N LL rd_ � +N<•Ltl ? L1 D( C Q g _ gYf1>ff V o P c Ha $� m� a1 q =s jT W o® Akk r � € MITSUBISHI ELECTRIC • CERTIFIED COOLING & H E A T I N G Live Better J T US 3400 Lawrenceville Suwanee Rd u>ro Suwanee,GA 30024 ntertek Tele:678-376-2900•Fax:800-889-9904 Toll Free:800-433-4822 www.mehvac.com FORM#PKA-A30KA4-PUY-A30NHA4(-BS)-201302 Specifications are subject to change without notice. 0 2013 Mitsubishi Electric US,Inc. • •' ./ .� �Ff ; , t- '-'+�'�!.!�` 'ice• '� 1's � �""'- s -�! � ' ,c_' �•wL�:� . ''F�,i; - j � 1■ :1 "-� � � i , • 'a tx•: to -_ �+. •' ,� - ' � •. � .� 111 1 'R I�• _-mow. �+�,� ..{,. :r i L toil, t : �►� V u a .=f.> s"�4 is w - ti,;.,�. s• L�.. 'location of outdoor unit _ �� "F - •�' .Y- ���_ � ors. �_.. Lis ill •��. Cascade Valle H � _� - ♦- � - . .r - • _ 1 + Wit' •�-. �` •� d �T i '. ,{� _ '•` ��}.�/']� - -rr_ j 7�. 2 i' , i s', a �':.. ` X ~� c a, i�Y jY• �,.p,�,aw.'.�O .:� y '• de VgyL ' �` +'' :EMT t, '.1� ju►ts�"' I _. }t7 � + a Am .., •.. - c '-• ,- - :t .: .� (''�. •�,x � � I""�'j4, :,:..rv. J 1 • ! ' -.�- .,• t,a -,> - `'' a.�..,_ • �j �- �,�+-•�. �1 .�• •t 'i .' �,• '•• _ - - -, _- .- -� �,' r .,' _• tip. p���.! �i�� .N, . t.:• � � �. '-•'... _ -mow. � r, ,E, N.� '� L S;••y.��• �w'l fir. i1 � `- ~.� r.�✓•• f j':�r� ,✓,-:.w. I/( 1 • '� .i'J. L� 1.+'. 7 ►,�~ le %� s„ •'S �:� y A Imagery Date: 8%25/%2011 48011'19.47" N 122°07'05 51% elev 209 ft eye alt 1051 PU Y - A 30N1 Af z� o� oz-3 ro raw « IN fj / r 6 �. S,3j I � Re-tr) cr .t ��n15 Q b sus ;v1JJ — �'lt� — - 6 �e i "y 1 0 Z I `� 626A , W _ •� !f(w.. PtIii7l4 O V L .. t — i //per] -t- c p P u � Ni � I I I � + � RECEIVE® 01 a AUG 2 9 2013 C0A Engineering Dept. FLOOR PLAN- GROUND FLOOR 1987 TOWER f �d M T09ER 25,2DID J(� t 425J7d.100 21911"600AveMsul1e210 f 425.774-7803 Edmonds WA"025 TG9 PROJECT 07018 [nfoltpbud*emm n .,wwap6smMiects.com Permit#: 182 Permit Date: 08/29/13 Permit Type: COMMERCIAL MECHANICAL Project Name: Cascade Valley Hospital Applicant Name: Applicant Address: Applicant, City, State, Zip: Contact: Phone: 360-366-9900 Tom Bajema Email: Scope of Work: Valuation: 9000.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 09/05/2013 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Launa Black Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 31051100102900 330 S STILLAGUAMISH PUBLIC HOSPITAL 651 Medical&Other AVE DISTRICT#3 Health Services Contractors Contractor Primary Contact Phone Address Contractor Type License License# Andgar Mechanical Dale Vanrooyen 360-366-9900 6920 Salashan MECHANICAL COA 604 255 353 LLC Parkway CONTRACTOR Andgar Mechanical Dale Vanrooyen 360-366-9900 6920 Salashan MECHANICAL Labor&ANDGAML825N3 LLC Parkway CONTRACTOR Industries CASCADE VALLEY 330 S HOSPITAL O-Ext. Stillaguamish OWNER Avenue Plan Reviews Date Review Type Description Assigned To Review Status 08/29/2013 COMMERCIALMECHANICAL AC-Heat Pump unit is approved. z.Christopher Young 08/29/2013 COMMERCIAL Launa Black MECHANICAL Fees Fee Description Notes Amount Mechanical Base Permit Fee $50.00 Mechanical Commercial Plan Review Table 4-1 $200.00 Total $250.00 Attached Letters Date Letter Description 08/30/2013 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 09/05/2013 Andgar check#82383 Launa Black $250.00 Outstanding Balance $0.00 Uploaded Files Date File Name 08/29/2013 BLD-182.pdf