HomeMy WebLinkAbout124 N Stillaguamish Ave_BLD4215_2026 CITY OF ARLINGTON
18204 59th Avenue NE,Arlington,WA 98223
INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551
124 N STILLAGUAMISH AVE BUILDING PERMIT
Permit#: 4215
Parcel#: 00455400501600 PERMIT EXPIRES 180 DAYS AFTER
Scope of Work: Construction of new SFR DATE OF ISSUANCE.
OWNER Valuation:403779.00
APPLICANT 116 STILLY LLC Stilly 3 LLC CONTRACTOR
903 200TH ST NE Acme Homes
10211 180th St SE 10211 180th St SE
ARLINGTON,WA 98223 Snohomish,WA 98296
Snohomish,WA 98296
425-361-5914/425-361-5914 425-361-5914
MECHANICAL CONTRACTOR LIC:ACMEHHL859RC EXP: 12/03/2021
PLUMBING CONTRACTOR
LIC#: EXP:
LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Single Family Residence
STORIES: CODE YEAR: 2018
2 CONST. TYPE: VB
DWELLING UNITS: 1
BUILDINGS: OCC GROUP: R-3
OCC LOAD:
PERMIT APPROVAL
The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any
other ordinance or order of the City, of any state or federal law,or of any order,proclamation,guidance advice or decision of the
Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any
period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance
advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid. The building
official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this
jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,
guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is
determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information,or in violation of any City
ordinance,regulation or order, state or federal law,or any order,proclamation,guidance or decision of the Governor.
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK
AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE
OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY/AND
ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN
MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC I10/IRCI10.
SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on
your sales tax return form and coded City of Arlington#3101.
14-
Signa ure Print Nam
Date Released By Da e
CONDITIONS
Permit#: 4215
Permit Date: 10/26/21
Permit Type:
Project Name: Stilly 3 Lot 18
Company/Applicant Name: Stilly 3 LLC
Company/Applicant Address: 10211 180th St SE v-1
City, State, Zip: Snohomish, WA 98296 J \
Contact: Robert Cumming/Kristi Kyle C1J 2 J
Phone: 425-361-5914/425-361-5914
Email: acmekristi@gmail.com
Permit Type: Single Family Residence
Valuation: 403779.00
Square Feet: 2535
Number of Stories: 2
Type of Construction: VB
Occupancy Type: R-3; Residential
Scope of Work: Construction of new SFR
MIC/Opportunity Zone:
Permit Issued:
Permit Expires: 03/07/2022
DNU:
Status: M PROCESS
Assigned To: Raelynn Jones
Property
Parcel# Address Legal Description Owner Name Owner Phone Zoning
116 STILLAGUAMISH WILLETT 100 SINGLE
00455400501600 AVE MARIDEE FAMILY
RESIDENCE
Contractors
Contractor Primary Contact Phone Address Contractor Type License License#
Acme Homes Kristi Kyle 425-361-5914 10211 180th St SE CONTRACTOR L&I ACMEHHL859RC
Plan Reviews
Date Review Type Description Assigned To Review Status
10/26/2021 Residential Dwelling BUILDING In Review
10/26/2021 Residential Dwelling PLANNING In Review
RESIDENTIAL PERMIT APPLICATION
Department of Community & Economic Development
O' City of Arlington- 18204 59th Ave NE -Arlington,WA 98223 - Phone(360)403-3551
THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE,
ADDITION, DECK, OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS
OF CONSTRUCTION DRAWINGS AND TWO(2)SETS OF STRUCTURAL CALCULATIONS. THE APPLICATION MUST
ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS. THE ZONING
VERIFICATION MAY BE SUBMITTED PRIOR.
Project Address: �
XXX Stillaguamish Ave,Arlington WA W Plat: Giffords 1st Addition to Arlington
LA G a {AQ.1 M+%LxN
Single-family ❑ Duplex ❑ Townhouse ❑= Addition ❑ Accessory structure
Proposed Area: V Floor: 1107 SF 2"d Floor: 1058 SF Garage:370 SF Total SF: 2535 SF
Describe Proposal (include cross street):
Construction of a single family residence located on Stillaguamish Ave. The underlying address is 116
Stillaguamish Ave. There is 3 legal parcels are under that address. New addresses will be necessary.
Valuation:_ L4 3.11 �l
Owner: Stilly 3 LLC
Address:10211 180th St SE City: Snohomish State:WA Zip Code: 98296
Phone: 425.361.5914 Email: acmekristi@gmail.com
Applicant: Acme Homes LLC /Attn Robert B Cumming
Address: 10211 180th St SE City: Snohomish State: WA Zip Code: 98296
Phone: 425.361.5914 Email: Acmekristi@gmail.com
Contractor:
Acme Homes LLC
Address: 10211 180th St SE City:Snohomish State: WA Zip Code: 98296
Phone: 425.361,5914 Email. acmekristi@gmail.com
Kristi Kyle ACMEHHL859RC 12/03/2021
e
Contact Person: y License Number. Expiration:
Received
SEP ® 8 2021
'BI_O - y2_%5
6/16LP Page 1 of 3
RESIDENTIAL PE
RMIT APPLICATION
Department of Community & Economic Development
City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551
Plumbing Section (continue filling out if plumbing is involved)
(Check all that apply and indicate the number of fixtures proposed)
Bath/Shower Combo (4.0) x KITCHEN
2 ❑ Sink (1.5) x 1
❑ Shower (2.0) x 1 ❑ Lavatory (1.0) x 5
❑ Clothes Washer (4.0) x 1 ❑ Water Closet(2.5) x 4
❑ Dishwasher (1.5) x 1 ❑ Water Heater x
1
J Hose Bibb (2.5) x 2 Water Heater Model#
❑ Other (list) x
Plumbing Section Continued
Proposed Water Piping Size: inch — Proposed DWV Material:
Proposed Piping Material:
Proposed DWV Size: L}
All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019
• All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV)
6/16LP
Page 2 of 3
RESIDENTIAL PERMIT APPLICATION
® Department of Community & Economic Development
p City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551
Mechanical Section (continue filling out if mechanical equipment is involved)
Select proposed appliances:
❑ Furnace (80+) Model# AFUE /ASSPp
Heat Pump Model # M AZ-ICay NE�1�Z D.-L1LSEER jjQ.0 N#rr
❑ AC Unit Model# r _ SEER
❑ Type II Hood Di Commercial Cooking Appliance ❑ Hydronic Piping
❑ Boiler Solid-Fuel Appliance ❑ PV System
''T Fireplace Insert ❑ Outdoor BBQ ❑ Storage Tank
❑ Freestanding Stove Gas Piping ❑ Other
Gas Piping Information
Not Applicable: ❑ %CU00g (41-Ats¢¢.l 1.000 gri
Pipe Material: Pipe Size: _ Total BTU's of all Appliances: 30.100 1
Distance from Meter to Furthest Appliance: +/- 60 feet
• New gas piping requires a pressure test to hooking to any appliance
• Sediment traps (drips) are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
tA
SU ,,S 1CZ-3G2��1� tZ L Date:
S• 2)
� --
f -
6 Page 3 of 3
NASH &ASSOCIATES
ARCHITECTS
PLAN 2165
BEAM,
LATERAL
and
SEISMIC
CALCULATIONS
RC-Fa19TEi2ED
AR—HIT11 T
MtG YNE JOHN50
9TA7E OF WA9HINIWOH ONF I C A" Copy 2018 IBC
JULY 2021 Received
8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117 S
W".NASH—MCffl=TS.COM
NASH & ASSOCIATES
ARCHITECTS
BEAM CALCULATIONS
2018 IBC
8003 118th Ave. NE. Kirkland. WA 98033 (425) 828-4117
WWW.NASH—ARCHITECTS.COM
CLIENT:
II NASH t ASSOCIATES BEAM DESIGN DATA PROJECT:
II ARCHITECTS DATE-
NAME:
Roof Loads:
LL 25#/sf
DL 15 #/sf
Total 40#/sf
Unless Noted Otherwise
Floor Loads:
LL 40#/sf
DL 10 #/sf
Total 50#/sf
Deck Loads:
LL 60#/sf
DL 10 #/sf
Total 70#/sf
Soil• 1500 PSF Min.
Concrete: Per IBC 2018
Masonry. Per IBC 2018
Steel Per IBC 2018
Wood: Per IBC 2018
Nailing: Per IBC 2018
4" Beam Douglas Fir #2
fv = 180
fb = 900 PSI
E = 1,600,000
6" Beam Douglas Fir #2
fv = 170
fb = 875 PSI
E = 1,300,000
Joists & Hem Fir #2
Rafters: fv = 150
fb = 850 PSI
E = 1,300.000
Glu—Lam Beams:
fv = 240 PSI
fb = 2,400 PSI (reduced by size factor, CF*I(I)
E = 1.800,000
8003 118th Ave. NE. Kirkland, RA 98033 (425) 828-4117
WWW.NASH—ARCHITECTS.COM
PLAN 2615
BeamChek v2018 licensed to:Nash&Associates Architects Reg#6464-622
LOFT
RB-1 Date:7/13/21
Selection 4x 8 DF-L#2 Lu=0.0 Ft
Conditions NDS 2015
Min Bearing Area R1=2.5 in2 R2=2.5 in (1.5) DL Defl= 0.05 in
Data Beam Span 6.0 ft Reaction 1 LL 975# Reaction 2 LL 975#
Beam Wt per ft 6.17# Reaction 1 TL 1578# Reaction 2 TL 1578#
Bm Wt Included 37# Maximum V 1578#
Max Moment 2368'# Max V(Reduced) 1261 #
TL Max Defl L/240 TLActual Defl L/702
LL Max Defl L/360 LL Actual Defl L/>1000
Attributes Section in' Shear in TL Defl in LL Defl
Actual 30.66 25.38 0.10 0.05
Critical 24.28 10.51 0.30 0.20
Status OK OK OK OK
Ratio 79% 41% 34% 27%
Fb si) Fv(psi) E(psi x mil Fcl(psi)
Values Reference Values 900 180 1.6 625
Adiusted Values 1170 180 1.6 625
A0justments CF Size Factor 1.300
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft
Loads Uniform LL:325 Uniform TL: 520 =A
Uniform Load A
R1 =1578 R2=1578
SPAN=6 FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 2615
BeamChek v2018 licensed to:Nash&Associates Architects Reg#6464-622
CVRD.PORCH
PB-1 Date:7/13121
Selection 4x 10 DF-L#2 Lu=0.0 Ft
Conditions NDS 2015
Min Bearing Area R1=1.4 inZ R2=1.4 in (1.5)DL Defl= 0.11 in
Data Beam Span 12.0 ft Reaction 1 ILL 528# Reaction 2 ILL 528#
Beam Wt per ft 7.87# Reaction 1 TL 887# Reaction 2 TL 887#
Bm Wt Included 94# Maximum V 887#
Max Moment 2662 W Max V(Reduced) 773#
TL Max Defl L/240 TLActual Defl L/642
ILL Max Defl L/360 LLActual Defl L/>1000
Attributes Section in') Shear(in') TL Defl(in) ILL Defl
Actual 49.91 32.38 0.22 0.11
Critical 29.57 6.44 0.60 0.40
Status OK OK OK OK
Ratio 59% 20% 37% 28%
Fb(psi Fv(psi) E(psi x mil Fc (psi)
Values Reference Values 900 180 1.6 625
Adjusted Values 1080 180 1.6 625
Adjustments CF Size Factor 1.200
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft
Loa ds Uniform ILL:88 Uniform TL: 140 =A
Uniform Load A
R1 =687 R2=887
SPAN=12FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 2615
BeamChek v2018 licensed to:Nash&Associates Architects Reg#6464-622
MASTER BATH
B-1 Date:7/13/21
Se! c'0 4x 10 DF-L#2 Lu=0.0 Ft
Conditions NDS 2015
Min Bearing Area R1=2.4 inz R2=2.4 in2 (1.5) DL Defl= <0.01 in.
Data Beam Span 5.0 ft Reaction 1 LL 1200# Reaction 2 LL 1200#
Beam Wt per ft 7.87# Reaction 1 TL 1520# Reaction 2 TL 1520#
Bm Wt Included 39# Maximum V 1520#
Max Moment 1900 W Max V(Reduced) 1051 #
TL Max Defl L/240 TLActual Defl L/>1000
LL Max Defl L/360 LL Actual Defl L/>1000
Attributes Section W Shear in TL Defl in LL Defl
Actual 49.91 32.38 0.03 0.02
Critical 21.11 8.76 0.25 0.17
Status OK OK OK OK
Ratio 42% 27% 10% 11%
Fb(psi) Fv(psi) E(psi x mil Fc!(psi)
Values Reference Values 900 180 1.6 625
Adjusted Values 1080 180 1.6 625
tusrinents CF Size Factor 1.200
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft
Loads Uniform LL:480 Uniform TL: 600 =A
L Uniform Load A
C
0
R1 = 1520 R2=1520
SPAN=5 FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 2615
SeamChek v2018 licensed to:Nash&Associates Architects Reg#6464-622
GARAGE
B-2 Date:7/13/21
Selection (2)2x 12 DF-L#2 Lu=0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 1.9 in2 R2=1.9 in (1.5)DL Defl= <0.01 in.
Data Beam Span 4.0 ft Reaction 1 LL 960# Reaction 2 LL 960#
Beam Wt per ft 8.2# Reaction 1 TL 1216# Reaction 2 TL 1216#
Bm Wt Included 33# Maximum V 1216#
Max Moment 1216 W Max V(Reduced) 646#
TL Max Defl L/240 TL Actual Defl L/>1000
LL Max Defl L/360 LL Actual Defl L/>1000
Attributes Section W Shear in TL Defl(in) LL Defl
Actual 63.28 33.75 0.01 <0.01
Critical 16.22 5.39 0.20 0.13
Status OK OK OK OK
Ratio 26% 16% 3% 4%
Fb(psi) Fv(psi) E ( si x mil Fc L Osi)
Values Reference Values 900 180 1.6 625
Ad'usted Values 900 180 1.6 625
Adiustments CF Size Factor 1.000
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb=0.00 Le=0.00 Ft
Loads Uniform LL:480 Uniform TL: 600 =A
[ Uniform Load A
0
R1 =1216 R2=1216
SPAN=4 FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 2615
BeamChek v2018 licensed to:Nash&Associates Architects Reg#6464-622
GARAGE
B-3 Date:7/13/21
Selection 5-1/8x 12 GLB 24F-V4 DFIDF Lu=0.0 Ft i
Conditions NDS 2015
Min Bearing Area R1= 1.5 in2 R2=0.8 in' (1.5)DL Defl= 0.09 in Recom Camber=0.14 in
Data Beam Span 18.0 ft Reaction 1 LL 640# Reaction 2 LL 320#
Beam Wt per ft 14.94# Reaction 1 TL 945# Reaction 2 TL 540#
Bm Wt Included 269# Maximum V 945#
Max Moment 5457 W Max V(Reduced) 930#
TL Max Defl L/240 TLActual Defl L/952
LL Max Defl L/360 LLActual Defl L/>1000
Attributes Section in' Shear(inz) TL Defl in LL Defl
Actual 123.00 61.50 0.23 0.13
Critical 27.29 5.81 0.90 0.60
Status OK OK OK OK
Ratio 22% 9% 25% 22%
Fb(psi) Fv(psi) E(psi x mil) Fc!(psi)
Values Reference Values 2400 240 1.8 650
Adjusted Values 2400 240 1.8 650
Adiustments Cv Volume 1.000
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft
Loads
Point LL Point TL Distance
960 B=1216 6.0
Pt loads:
0
R1 =945 R2=540
SPAN=I8FT
Uniform and partial uniform loads are ibs per lineal ft.
PLAN 2615
BeamChek v2018 licensed to:Nash&Associates Architects Reg#6464-622
GREAT RM./KITCHEN/DINING
B-4 Date:7/13/21
Selection 5-1/8x 12 GLB 24F-V4 DF/DF Lu=0.0 Ft
Conditions NDS 2015
Min Bearing Area R1=6.5 in' R2=6.5 in' (1.5)DL Defl= 0.12 in Recom Camber--0.18 in
Data Beam Span 13.75 ft Reaction 1 LL 3300# Reaction 2 LL 3300#
Beam Wt per ft 14.94# Reaction 1 TL 4228# Reaction 2 TL 4228#
Bm Wt Included 205# Maximum V 4228#
Max Moment 14533 # Max V(Reduced) 3613#
TL Max Defl L/240 TL Actual Defl L 1400
LL Max Defl L/360 LL Actual Defl L/569
Attributes Section in' Shear in2 TL Defl in LL Defl
Actual 123.00 61.50 0.41 0.29
Critical 72.66 22.58 0.69 0.46
Status OK OK OK OK
Ratio 59% 37% 60% 63%
Fb (psi) Fv(psi) E(psi x mil Fc l (psi)
Values Reference Values 2400 240 1.8 650
Adjusted Values 2400 240 1.8 650
/dj is ents Cv Volume 1.000
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft
Loads Uniform LL:480 Uniform TL: 600 =A
Uniform Load A
R1 =4228 R2=4228
SPAN=13.75 FT
Uniform and partial uniform loads are Ibs per lineal ft.
NASH &ASSOCIATES
ARCHITECTS
LATERAL & SEISMIC
CALCULATIONS
2018 IBC
8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117
WWW.NASH—ARCHITECTS.COM FLi
CLIENT
;NASH&ASSOCIATES WIND AND SEISMIC DESIGN DATA PROJECT`.
A R C H I T E C T S PER 2018 IBC DATE:
NAME:
WIND DE516N CRITERIA
DESIGN PER ASCE 1-16
I. NOMINAL/ULTIMATE WIND SPEED V/asd /Vult 85/110 mph
2. RISK CATEGORY II 1.00
3. WIND EXPOSURE CATEGORY "B"
4. INTERNAL PRESSURE COEFFICENT +/-55
5. COMPONENTS AND CLADDING
DESIGN PRESSURE +/- 16 psf
BUILDINGS, STRUCTURES,AND PARTS THEREOF SHALL BE DESIGNED AND
CONSTRUCTED IN ACCORDANCE WITH STRENGTH DESIGN, LOAD, AND RESISTANCE
FACTOR DESIGN,ALLOWABLE STRES5 DESIGN,EMPIRICAL DESIGN OR CONVENTIONAL
CONSTRUCTION METHODS,AS PERMITTED BY THE APPLICABLE MATERIAL CHAPTER,SECTION 1604.1
BUILDINGS, STRUCTURES,AND PARTS THEREOF,SHALL BE DESIGNED TO WITHSTAND WIND LOADS
AS DEFINED IN SECTION 16041 AND A5GE 1-16
WIND DESIGN PER PART 2 "ENCLOSED 51MPLE DIAPHRAGM BUILDINGS PER ASCE 1-16, 5EGTION 21.4
(BUILDING HEIGHT 15 LESS THAN 160 FEET)- 51MPLIFIED METHOD
110 MPH ULTIMATE WIND SPEED
USE Iq.6 P5F PER TABLE 215.1 "EXPOSURE B"- 110 MPH (L/B- .05/1= Iqb ph- PAGE 288)
WOOD DESIGN PER SECTIONS 2304-2306. STRUCTURES USING WOOD SHEAR WALLS
AND DIAPHRAGMS TO RESIST WIND,SEI5MIG,AND ALL OTHER LATERAL LOADS SHALL
BE DESIGNED AND CONSTRUCTED IN ACCORDANGE WITH AF 4 PA 5DPW5 AND PROVISIONS
OF 5ECTION5 2505-2506
5E15MIG DE516N DATA
DESIGN PER A50E 1-lb/CHAPTER II
I. SEI5MIG IMPORTANCE FACTOR Is 1.00
2. SHORT PERIOD ACCELERATION Ss 15 "see footnote at bottom of page (0=1.0)
3. 1 SECOND ACCELERATION 51 0.148 "see footnote at bottom of page
4. SITE CLA55 D (default class per IBC and section 11.4.3)
5. SPECTRAL RESPONSE COEFFIGENT Sp, OAl2 *see footnote at bottom of page
6. SPECTRAL RESPONSE COEFFICIENT Sp 0.148 *see footnote at bottom of page
1. SEISMIC DESIGN CATEGORY D (per table 11.6-1 AND table 11.6-2)
8. SEISMIC FORGE RESISTING 5YST EM PLYNOOD SHEAR WALL5
q. DESIGN BASE SHEAR (see seismic calculations)
10. SEISMIC, RESPONSE COEFFICIENT Gg 0.15
11. RESPONSE MODIFICATION FACTOR R 6.5
12. ANALY515 PROCEDURE EQUIVALENT LATERAL FORGE
15. RISK CATEC70RY II (table IS-1)
THE ANCHORAGE OF WALLS SUPPORTING CONSTRUCTION SHALL BE BE
DESIGNED IN AGGORDANGE WITH ASGE 1-16,SECTION 12.14
IN STRUGTTIRES ASSIGNED TO SEISMIC DESIGN CATEGORY C-F,COLLECTOR ELEMENTS
AND THEIR CONNECTIONS TO VERTIGAL ELEMENTS SHALL BE DESIGNED TO RESIST
MAXIMUM EFFECTS AS SPECIFIED IN ASGE 1-16, SECTION 12.14
BASE SHEAR V= (F Sps/f) W
ANCHOR BOLTS, 5/5" DIA X 10", A301 OR BETTER W/1" MIN. EMBEDMENT.V= 1104#/BOLT
" PER U565, THE MAXIMUM S1 IN THE STATE OF WASHINGTON 15 0.148. ALL SEISMIC DESIGN VALUES USED
IN THIS ANALY515 ARE BASED UPON THIS NUMBER. SINGE 5115 LESS THAN 0.15,THEN USE SEISMIC CATEGORY
D IF RISK CATEGORY 15 I, 11,OR III
8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117
WWW.NASH—ARCE=TS.COM
A B
use' � use•
14.6 psP
N N N N
El
FRONT M-EVATION
I -
I
� I
El
aX
al I F
d
I �
Ill
y I I I
p I I
LL a a,
y
I I I
_ I �
°o
J �
z �
Q �
A B
M
N
i`rOOta i"M
/ Lr a r/ IS as
I 1
I I
I I
t I I
IZy I I
I I
' I�jup9a• I I
' M L—————————————--—————J
a•� F
--- — - ---- -- --- ---
O
4 W ?
MW
I
I
I
.Y.
as
t l l l l l l l
I t t l t l l
r�
a.n
Y
ILV
-- ---- r
II
II
II
II
II i�
ra I I
�� II
II
II
II
II
II
a
HOIDDOHN SCHEDULE
MARK HOLDOWN/ FASTENERS WOOD MEMBER ANCHOR
STRAP MAIN FLOOR
T-1 STHDI4/14 RJ 24-16d SINKER_ -
HF/SFF
T-2 MST45 (34)-16tl (2)2 4/2X6 STUDS
HF/SPF
T-5 MSTA55 (26)-IOd (2)2x4/2x STUDS
HF/5—
T-4 MSTC4 5-9 (S6)-IOd HF/SPF V V
7-5 HDU6-51P52.5 1 (20)SDS 1/4" 4x6 PST ?/$•ANCHOR
X 2-1/2" BOLT
A B
r �
N
I� C1 i
I I
I I
n I I
2
II �' w II
ih
t
III
0
111 �I�
I
I }
II I
11
II l---
11 -
11 -
II �II
II
HOLJ7E70 PI w--,HEDUI-E
MARK HOLDO"W FASTENERS WOOD MEMBER ANGHOR UPPER PILOOR
STRAP THIGKNE55/SPEGIES 4Fpl11GEp
T-1 STHP14/14 RJ 24-16d SINKER- (2)2X4/--b s --
HF/SPF
7-2 MS745 (34)-16d (2)2X4/1X6 STUDS
1-F/S
T-3 M5TA36 (26)-IOd (�)�X9/1X6 STUDS
HF/SFF
T-4 MSTG4BS3
7-5 HOU5-50,52.5 (20)SAS I/4" �X X6 STUDS 7111 ANGHOR
X 2-I/2' BOLT
CLIENT:
N
m*ASSOCIATES LATERAL DESIGN DATA PROJECI`.
ARCHITECTS DATE:
NAME:
1
SHEAR UNIT SHEAR
LINE LEVEL TOTAL SHEAR FORCE(#) WALL SHEAR WALL
LENGTH(ft) 0/110 TYPE
W H P Abv.
A 2 12-5 x 6.5 x 1916 + 6 = 160-51 27
1 12.5 x 9.5 x 19.6 + 1592.5 = 3920 24 .63.3 pi-6'
B 2 12.5 x 6.5 x 19.6 + 0 = 1592.5 36.5 43,6
1 12.5 x 9.5 x 19.6 ;+ 1592:5'= 3920 53 .4
1 1 12 x 9.5 x 19:6 + 0 = 2234 4 5.5 106.3 P1-3"
2 2 11 x 6.5 x 19.6 '+ 0 = 1401 4 19.5 71,9
1 17 x 9.5 x 1'9:6 + 1401.44= 4566 8 18 7'25 7l,% P1-4"
3 2 24.5 x 6.5 x 19:6 + 0 = 3121-3 22.5 138.7'A ':e j'
1 22 x 9.5 x 19:6 + 1121.3 = 7211-T 16.5 437.4 P1-3"
4 2 13 x 6.5 x 19:6 + 0 = 1656.2' 6 27E P1-4'
1 13 x 9.5 x 19.6 + 1656.2 = 4076,81 6 679i P2-"
8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117
Lm I WWW.NASH-ARCHITECTS.COM
SHEAR WALL. !BCHE �)UL F-
PER 2018 IBG
GENERAL NOTES:
SEE PLANS TO DETERMINE THE DIFFERENT DESIGNATORS FOR SHEAR WALL MATERIALS,
NAILING, ANCHOR BOLTS, AND HOLDOWN5. LOCATE HOLDOWN5 AS OL05E AS POSSIBLE TO THE END
OF THE DESIGNATED WALL.
ALL HOLDOWN5, ANCHOR BOLTS, WA51 IER5, 4 NAILS IN CONTACT WITH P.T. WOOD TO BE
HOT DIPPED GALVANIZED.
PI = ONE SIDE PLYWOOD
P2 = TWO 51DE5 PLYWOOD
NAIL SPACING P-35 SILL OPTIONAL BASE HEM FIR#2
MARK '1/16" OP 4 BTM.ANCHORS BLKG. PLATE 51MPSON MA5AP PLATE VALUE
PLYWD. EDGES FIELD PLATES dgelatl tZEQ'D. ANCHOR BOL ANCHORS NAILING (#/LF)
PI-6" 8d roll 12" b" 15,10.0. 2x4 5/8"0 48" 1 ® 48" 4 ENDS (2) Ibd 0 10" 240
PI-4" 8d 4" 12' 4" 16" O.G. 2x4 5/8"0 32" ® 30" 4 ENDS (2) Ibd 01" 344
PI-3" *• 8d V. 12' 3" 14" O.G. (2) 2x4/6 5/8"0 24" ® 24" 4 ENDS (2) Ibd®5" 450
PI-2" ** 8d 2" 12" 2" 12" O.G. (2) 2x4/6 5/4"0 24" ® 18" 4 ENDS (2) Irod®5" 585
P2-roll ** 8d 6" 12" 6" 10" D.G. (2) 2x4/6 5/8"® 24" WA (2) Ibd 0 5" 480
P2-4" '* 8d 4" 12" 4" 8" O.G. (2) 2x4/6 3/4"0 20" WA (3) Ibd®5" 100
172-3" ** 8d 3" 12" 3" 8" O.G. (2) 2x4/6 3/4"® Ib" WA (4) Ibd®5" 400
P2-2" ** 8d 2" 1 12" 2" 8" O.G. (2) 2x4/6 3/4"0 12" WA (4) 16d 0 4" 11-70
"*NOTE: WALLS WITH UNIT SHEAR OF 350#/Ft. OR GREATER SHALL HAVE FRAMING
MEMBERS (STUDS 4 PLATES) ABUTTING PANELS NOT LE55 THAN 3X MEMBERS OR(2) 2X MEMBERS
PER IBG 2015 AND 5DPW5-2015
PER SPECIAL DESIGN PROV1510N5 FOR WIND AND SEISMIC,CHAPTER
4.3.1.1 #4 E:XPEGTION;(2) 2X MEMBERS ARE OK IN LIEU OF 3X
MEMBERS
STITCH NAIL DOUBLE STUDS AND PLATES TOGETHER WITH
Ibd NAILS ® 12" O.G. STAGERRED ON THE STUD FACE
I. USE POWER-DRIVEN STEEL STUDS AND NAILS BY HILTY OR RAMSET WHERE APPLICABLE.
2. PLYWOOD MAY BE INSTALLED EITHER HORIZONTALLY OR VERTICALLY.
3. SOLID BLOCK WITH JOIST UNDER INTERIOR SHEAR HAI15.
SHEAR WALL NOTES
1/16" 055 OR PLYWOOD SHEATHING - USE 8d COMMON OR GALVANIZED NAILS. BLOGK ALL PANEL
EDGES. LONG DIMEN51ON5 OF PLYWOOD MAY BE INSTALLED VERTICALLY. NAIL ® 12" O.G. TO ALL
INTERMEDIATE 5TUD5. WHERE 3" NAIL SPACING 15 SPECIFIED AT PANEL ED6E5, U5E 1-1/2" 8d
SHORT NAILS OR 3X STUDS WITH 8d COMMON NAILS. FOR 2" NAIL SPACING, U5E 3X 5TUD5
AND 5TA66ER PANELS. WHERE PLYWOOD 15 2 51DE5 OF WALL, JOINT5 TO FALL ON
5EPARATE 5TUD5 ON EACH 510E.
FLOOR PLYWOOD - USE 8d COMMON NAILS ® 10" O.G. AT INTERMEDIATE SUPPORTS,6" O.G.
AT ALL PANEL EDGE5 AND 4" O.G. AT ALL SHEAR WALL5, UNLESS OTHERWISE SHOWN ON PLAN5.
FLOOR JOISTS - JOIST PARRALLEL TD FLOOR OPENINGS AND EXTERIOR WALLS SHALL BE
GRO55 BLOCKED AT 48" O.G. ® EDGES W/(4) IOd NAILS FOR THE FIRST BAY.
3" x 3" x 1/4" SQUARE WA5HER5 AT ALL ANCHOR BOLTS. PLATE WASHER5 TO BE INSTALLED WITHIN
1/2" OF SHEATHING
7/I6" 055 OR PLYWOOD 5HEATHIN6 - STAPLE 56HEDULE
ALLOWABLE SHEAR VALUES WITH HEM FIR#2 5TUD5
2" 16 GA. STAPLES ® 15 GA. STAPLES ® 14 GA. STAPLES
3" O.G. -280 #/ft. 4" O.G. - 280#/ft. 4' O.G. - 303#/ft.
2" O.G. - 360#/ ft. 2-1/2" D.G. - 430#/ft. 3" O.G. - 340#/ft.
4' O.G. AND IOd NAILS 2" O.G. - 504#/ft.
® 6" O.G. - 620#/ft.
FIELD 5PAGING: 12" O.G. NAILS 4 STAPLES.
HOLDOWN5 - INSTALL SIMPSON HOLDOWNS OR U5P HOLDOWN5 AT THE END OF SHEAR WALL5
WHEN SHOWN ON DRAWINGS.
PER PLAN, SIMPSON STHDI4 OR USP 5TAD14 5IMP50N M5T3b OR U5P M5TI36
51MP50N M5T48 OR U5P K5T248 SIMP50N HDUB OR USP TDXIO (36" ANCHOR BOLT MIN.
51MP50N MST048B3 OR USP M5TG54B3 24" EMBEDMENT, 3' BOLT INTO (3) 2x4(ro))
CLIENT:
NASH&ASSOCIAM SEISMIC ANALYSIS PROJECT:
ARCHITECTS DATE:
NAME-
Weight of Building:
Roof Assembly:
Asphalt Shingles - 2.00#/ft Cedar Shakes - 2.25#/ft Tile - 9.50#/ft
Felt - 0.15 #/ft Felt - 0.15 #/ft Felt - 0.15 #/ft
1/2" Plywood - 1.50 #/ft 1/2" Plywood - 1.50 #/ft 1/2" Plywood - 1.50 #/ft
Trusses ® 24" o.c. - 1.75 #/ft Trusses @ 24" o.c. - 1.75 #/ft Trusses ® 24" o.c. - 1.75 #/ft
R-38 Insulation - 2.35 #/ft R-30 Insulation - 2.25#/ft R-30 Insulation - 2.25#/ft
1/2" GWB Ceiling - 2.00#/ft 1/2" GWB Ceiling - 2.00#/ft 1/2" GWB Ceiling - 2.00#/ft
Total 9.75#/ft Total 9.90#/ft Total 17.90#/ft
Use 10.00#/ft Use 10.00#/ft Use 18.00##/ft
1st & 2nd Floor Assembly:
Caret / Pad - 0.50 /ft Hardwood - 2.50#/ft3/4' T&G Plywood - 2.50#/ft 3/4" T&G Plywood - 2.50#/ft
2x10 @ 16" o.c. - 2.30#/ft 2x10 ® 16" o.c. - 2.30#/ft
1/2" GWB Ceiling - 2.00#/ft 1/2" GWB Ceiling - 2.00##/ft
Total 7.30#/ft Total 9.30#/ft
Use 10.00#/ft Use 10.00#/ft
Interior Wall Assembly: Exterior Wall Assembly:
1/2" GWB - 2.00#/ft 3/4" Wood Siding - 2.30#/ft
2X4 ® 16" o.c. - 1.10 #/ft 1/2" Plywood - 1.50 #/ft
1/2" GWB - 2.00#/ft 2x6 @ 16" O.C. - 1.37 #/ft
Total 5.10 #/ft R-21 Insulation - 2.10 /ft
Use 8.00#/ft 1/2" GWB - 2.00 /ft
Total 9.27#/ft
Use 10.00#/ft
4" Brick Veneer - + 3.20#/ft
8003 118th Ave. NE. Kirkland. WA 98033 (425) 828-4117
WWW.NASH-ARCETrECTS.COM
CLIENT:
I� NASH&ASSOCIATES SEISMIC ANALYSIS PROJECTC
II ARCHITECTS DATE:
NAME:
2
2nd Level:
Roof. Asphalt/Cedar Shake 10 #/ft x 1058 SF = 10580
Tile 18 #/ft x SF = 0
L 1/2(h)
Exterior Walls: 140 x 10#/SF x 4.04 = 5656 (E2)
Interior Walls: 85 x 8#/SF x 4.04 i = 2747.2 (12)
Total: = 18983.2 or 19'i k
1st Lexel:
Roof. Asphalt/Cedar Shake 10 #/R x 419 SF = 4.190
2nd Floor. 18 #/ft'x. 1058 SF = 19044
L 1/2(h) (E2)
Exterior Walls: 175 x 10#/SF'x; 4.5 +, 5656 = 13531 (El)
(12)
Interior Walls: 65 x' 8#/SF x 4.5 '+ 2747.2 = 5087.2 (11)
Total: = 41`8522 or 41.9-k
8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117
WWW.NASH—ARCHITECTS.COM
CLIENT:
NASH&ASSOCIATES SEISMIC ANALYSIS PROJECT
II ARCHITECTS DATE:
NAME.
3
Wdl Cs V
LEVEL 2: 1.91 x 0113 = 2;5
LEVEL 1 4,1.9 x 0:13 = 5.4
TOTAL: 60,91 x 0.13 zj 7.9
SHEAR @ STORY
LEVEL DEAD LOAD HIGHT MOMENT Fx= REMARKS
h
(Wdl) ( ) (Wdl)(h) [(Wdl)(h)]V/
[(Wdl)(h)] ALPHA I NUMERIC
2 19 18 342 48% 3.791 2 1.9 3 1.3
1 41.9 9 .377.1 52% 1 4.11 2 2.1 4 1
TOTAL 1 60:91 1 719.1 100% 1 7A
8003 118th Ave. NE. IGrkland, WA 98033 (425) 828-4117
WWW.NASH—ARCHITECTS.COM
I
7;
CLIENT:
NASH&ASSOCIATES SEISMIC ANALYSIS PROJECT:
ARCHITECTS DATE:
NAME:
4
LINE LINE WALL Vmax WIND WALL OVER SHEAR
LEVEL LINE SHEAR TOTAL P> 1 SEISMIC(31ft) TURNING
SHEAR ABOVE LENGTH V/14 SHEAR RIGHT FORCE WALL
2 A 1.9 0 1.9 27 70 50 59 8.08 476.72
B 1.9 0 1.9 36.5 52 37 43.6 8.08 352.288
2 1.3 0 1.3 19.5 67 48 71.9 8.08 580.952
3 1.3 0 1.3 22.5 58 41 138.7 8:08 1120,69E -
4 1.3 0 1.3 6 217 155 276 808 2230.08 P14"
LINE LINE WALL j Vmax OVER SHEAR
LEVEL LINE SHEAR TOTAL P> 1 SEISMIC(31ft WIND WALL) TURNING
SHEAR ABOVE LENGTH ' V 11.4 SHEAR HIGHT FORCE WALL
1 A 2.1 1.9 4 24 167 119 163.3 9 1469.7 P1-6"
B 2.1 1.9 4 53 75 54 74 9 666 -
1 1 1.3 2.3 5.5 4181
299 406.3 9 3656.7 P1-3"
2 1 1.3 2.3 18 1281 91 253.7 9 2283.3 P1-4"
8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117
WWW.NASH-ARCHITECTS.COM
CLIENT`.
II NMH&ASSOMIN SEISMIC ANALYSIS PROJECT.
II ARCHITECTS DATE:
NAME:
6
Redundancy Factor (p):
1. MAXW M ALLOWABLE WAIL SHEAR FOR P<=1
VUMAX = (2)(VACCSTORY)/ABTA
2( 7.9 ) 15.8
Vumax = = 38.4 = 0.4
1477
2. MAXIMUM ACTUAL SHEAR
VUMAX = LARGEST SEISMIC WALL SHEAR
0.4 > 0.357
3. P = 2—(2(VACCSTOR7)/(VUh"(AB'A)
P = 2 [ 2( 7.9 ) ] = 1
( 0.4 38.4 )
8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117
WWW NASH—ARCHITECTS.COM
2018 Washington State Energy Code—Residential
Prescriptive Energy Code Compliance for All Climate Zones in Washington_
Single Family_—New&Additions(effective February 1,2021)
These requirements apply to all IRC building types,including detached one-and two-family
dwellings and multiple single-family dwellings(townhouses).
Prof
!!q Dion Contact Information
Plan 2165 Mike Johnson Nash&Asso Architects
michael Nash-Architects.com
Instructions:This single-family project will use the requirements of the Prescriptive Path below and
incorporate the minimum values listed.Based on the size of the structure,the appropriate number of
additional credits are checked as chosen by the permit applicant.
Provide all information from the following tables as building permit drawings:Table R402.1-Insulation and
Fenestration Requirements by Component,Table R406.2-Fuel Normalization Credits and 406.3-Energy Credits.
Authorized Representative I Date ,07/14/2021
All Climate Zones(Table 11402.L1
R-Value a U-Factor a
Fenestration U-Factor b n/a 0.30
Skylight U-Factor b n/a 0.50
Glazed Fenestration SHGC b,e n/a n/a
Ceiling e I 49 0.026
-Wood Frame Wall 9,h 21 int I 0.056
Floor 30 0.029 I
Below Grade Wall c•h 10/15/21 int+TB 0.042
Slab d•f R-Value&Depth 10,2 ft n/a
R-values are minimums. U-factors and SHGC are maximums.When insulation is installed in a cavity that is less
a than the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix
Table A101.4 shall not be less than the R-valuespecified in the table.
b IThe fenestration U-factor column excludes skylights.
'10/15/21+5TB"means R-10 continuous insulation on the exterior of the wall,or R-15 continuous insulation on
the interior of the wall,or R-21 cavity insulation plus a thermal break between the slab and the basement wall at
c the interior of the basement wall."10/15/21+5TB"shall be permitted to be met with R-13 cavity insulation on
the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5TB"
means R-5 thermal break between floor slab and basement wall. - J
d R-10 continuous insulation is Tgulred under heated slab on grade floors.See Section R402.2.9.1. I
For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38 if the full insulation depth
e 4 extends over the top plate of the exterior wall.
R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter
f slab insulation when applied to existing slabs complying with Section R503.1.1.If foam plastic is used, it shall
meet the requirements for thermal barriers rp otecting foam plastics.
For log structures developed in compliance with Standard ICC 400,log walls shall meet the requirements for
g climate zone 5 of]CC 400.
Int.(intermediate framing)denotes framing and insulation as described in Section A103.2.2 including standard
h framing 16 inches on center,78%of the wall cavity insulated and headers insulated with a minimum of R-10
insulation. _.
!FFICE COPY
Received
�-LAz,5
Prescriptive Path—Single Family 2018 Washington State Energy Code-R 1
i
2018 Washington State Energy Code-Residential
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Single Family-New&Additions(effective February 1,2021)
Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel
normalization credits)and Table 406.3 (energy credits)to achieve the following minimum number of
credits.To claim this credit,the building permit drawings shall specify the option selected and the
maximum tested building air leakage,and show the qualifying ventilation system and its control sequence
of operation.
1. Small Dwelling Unit:3 credits
Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area.
Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf.
2. Medium Dwelling Unit:6 credits
All dwelling units that are not included in#1 or#3
3. Large Dwelling Unit:7 credits
Dwelling units exceeding 5,000 sf of conditioned floor area
4. Additions less than 500 square feet: 1.5 credits
All other additions shall meet 1-3 above
Before selecting your credits on this Summary table,review the details in Table 406.3(Single Family),on page 4.
Summary of Table R406.2
Heating Credits-select ONE
Options Fuel Normalization Descriptions heating option User Notes
P
1 Combustion heating minimum NAECAb 0.0 ❑
2 Heat pump` I 1.0 0 Electric Heat Pump
3 Electric resistance heat only-furnace or zonal -1.0 ❑
4 DHP with zonal electric resistance per option 3.4 0.5 I ❑
L 5 All other heating systems -1.0 ❑
Energy Credits-select ONE
Energy Credit Option Descriptions energy category
from each
Options a
g ry I _
1.1 NIMOMDu[tf1ffl0 ?? ®De 0.5 i ❑
1.2 1 Efficient Building Envelope 1.0 ❑
1.3 Efficient Building Envelope 0.5 M
' 1.4 Efficient Building Envelope 1.0 ❑
1.5 Efficient Building Envelope 2.0 ❑
1.6 Efficient Building Envelope 3.0 ❑
1.7 1 Efficient Building Envelope 0.5 ❑
2.1 Air Leakage Control and Efficient Ventilation 0.5 0
2.2 Air Leakage Control and Efficient Ventilation 1.0 ❑
2.3 Air Leakage Control and Efficient Ventilation 1.5 ❑
2.4 Air Leakage Control and Efficient Ventilation 2.0 ❑
3.la High Efficiency HVAC 1.0 ❑
3.2 High Efficiency HVAC 1.0 ❑
3.3' High Efficiency HVAC 1.5 ❑
3.4 High Efficieny HVAC 1.5 ❑
3.5 High Efficiency HVAC 1.5 ❑
3.61 Hi h Efficiency HVAC 2.0
4.1 High Efficiency HVAC Distribution System 0.5 ❑
4.2 High Efficiency HVAC Distribution System 1.0 ❑
Prescriptive Path-Single Family 2018 Washington State Energy Code-R 2
2018 Washington State Energy Code—Residential
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Single Family—New&Additions(effective February 1,2021)
Summary of Table R406.2(cont.)
Energy Credits-select ONE
Options Energy Credit Option Descriptions(cont.) eneeargy oaption from User Notes
_ �r
5.1' Efficient Water Heating I 0.5 ❑
5.2 Efficient Water Heating 0.5 1 ❑
5.3 Efficient Water Heating 1.0 1 ❑
5.4 Efficient Water Heating 1.5 1 ❑
5.5 Efficient Water Heating 2.0 0
5.6 Efficient Water Heating 2.5 ❑
6.1e Renewable Electric Energy(3 credits max) 1.0 Q
7.1 Appliance Package 0.5
Total Credits _ 1 6-01 CLEAR FORM
a. An alternative heating source sized at a maximum of 0.5 W/sf(equivalent)of heated floor area or 500 W,
whichever is bigger,may be installed in the dwelling unit.
b. Equipment listed in Table C403.3.2(4)or C403.3.2(5)
c. Equipment listed in Table C403.3.2(1)or C403.3.2(2)
d. You cannot select more than one option from any category EXCEPT in category 5.Option 5.1 may be combined
with options 5.2 through 5.6.See Table 406.3.
e. 1.0 credit for each 1,200 kWh of electrical generation provided annually,up to 3 credits max.
See the complete Table R406.2 for all requirements and option descriptions.
Tease print only pages 1 through 3 of this worksheet for submission to your buii,.
Prescriptive Path—Single Family 2018 Washington State Energy Code-R 3
Window, Skylight and Door Schedule
Project Information Contact Information
Plan 2165 Mike Johnson @ Nash &Asso Architects
(425) 242-7490
michael Nash-Architects.coin
Width Height
Ref. U-factor Qt. Feet Inch Feet Inch Area UA
Exempt Swinging Door(24 sq. ft. max.) E=-] 0.0 0.00
Exempt Glazed Fenestration (15 sq.ft. max.) 1 0.01 0.00
Vertical Fenestration (Windows and doors)
Component Width Height
Description Ref. U-factor Qt. Feet Inch Feet Inch Area UA
Dining/GR Single Hung 0.28 4 3 ° 6 ° 72.0 20.16
Foyer Entry Door 0.28 1 3 ° 8 ° 24.0 6.72
Garage Door 0.20 1 2 e 6 B 17.8 3.56
GR Picture 0.28 2 2 ° 4 ° 16.0 4.48
Kitchen Single Hung 0.28 1 3 ° 4 6 13.5 3.78
Master Single Hung 0.28 2 13 " 5 ° 30.0 8.40
Powder Single Hung 0.28 3 2 " 4 ° 24.0 6.72
Mudroom Entry Door 0.28 1 3 ° 6 C 20.0 5.60
Stair Single Hung 0.28 2 3 ° 5 ° 30.0 8.40
BDRM Picture 10.28 6 2 ° 2 ° 24.0 6.72
Loft/BDRM Single Hung 10.28 7 3 ° 5 ° 105.0 29.40
Bath Single Hung 0.28 1 2 ju 3 ° 6.0 1.68
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.01 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.01 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
Sum of Vertical Fenestration Area and UA 382.3 105.62
Vertical Fenestration Area Weighted U=UA/Area 0.28
Overhead Glazing (Skylights)
Component Width Height
Description Ref. U-factor Qt. Feet In ' Feet Inch Area UA
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
Sum of Overhead Glazing Area and UA 1 0.01 0.00
Overhead Glazing Area Weighted U= UA/An:a 0.00
Total Sum of Fenestration Area and UA (for heating system sizing calculations) 1 382.31 105.62
Simple Heating System Size:Washington State
This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code(WSEC)and ACCA Manuals
J and S.This tool will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads.
Please complete the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some
values will be calculated for you.If you do not see the selection you need in the drop-down options,please contact the WSU Energy Program at
energycode@energy.wsu.edu or(360)956-2042 for assistance.
Project Information Contact Information
Plan 2165 Mike Johnson @ Nash&Asso Architects
(425)242-7490
Heating System Type: OAll Other Systems Heat Pump
To see detailed instructions for each section,place your cursor on the word"Instructions"
Design Temperature
Instructions Design Temperature Difference(AT) 47
Marys ale AT=Indoor(70 degrees)-Outdoor Design Temp
Area of Building
Conditioned Floor Area
Instructions Conditioned Floor Area(sq ft) 2,165
Average Ceiling Height Conditioned Volume
Instructions Average Ceiling Height(ft) 8.5 18,403
Glazing and Doors U-Factor X Area = UA
Instructions
u ore 0.280 332 107.04
Skylights U-Factor X Area = UA
Instructions 0.50 —
Insulation
Attic LR49
U-Factor X Area = UA
Instructions 0.026 1,062 27.61
Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA
Instructions select R-Value No selection
Above Grade Walls(see Figurel) U-Factor X Area UA
Instructions R 2t IntormedatcJ 0.056 2,274 127.34
Floors U-Factor X Area UA
Instructions 0.025 F 1,487 37.18
R-36
Below Grade Walls(see Figural) U-Factor X Area UA
Instructions Below Grade Walls in this prajw 0.028
Slat b Below Grade("a Figure 1) F-Factor X Length UA
Instructions 0.303 —
No Slab Below Grade in thispfojee't.
Slab on Grade(seeFiguns 1) F-Factor X Length UA
Instructions
Na Slab on Grade in this proiec•
Location of Ducts
Instructions Duct Leakage Coefficient
Conditioned p o:c
1.00
Sum of UA 299.18
Envelope Heat Load 14,061 Btu/Hour
Figure 1. Sum of UA x AT
Air Leakage Heat Load 9,341 Btu/Hour
Volume x 0.6 x AT x 0.018
abev.<s.i4 Building Design Heat Load 23,402 Btu/Hour
Air leakage+envelope heat loss
-- Building and Duct Heat Load 23,402 Btu/Hour
Ducts in unconditioned space.sum of building heat loss x 1.10
Ducts in conditioned space.sum of building heat loss x 1
Maximum Heat Equipment Output 29,253 Btu/Hour
Building and duct heat loss x 1.40 for forced air furnace
Building and duct heat loss x 1.25 for heat pump
(07101113)
SUBDIVISION
Guarantee/Certificate Number:
Issued By:
CHICAGO TITLE INSURANCE COMPANY 500128087
CHICAGO TITLE INSURANCE COMPANY
a corporation, herein called the Company
GUARANTEES
TBD and TBD
herein called the Assured, against actual loss not exceeding the liability amount stated in Schedule A which the Assured
shall sustain by reason of any incorrectness in the assurances set forth in Schedule A.
LIABILITY EXCLUSIONS AND LIMITATIONS
1. No guarantee is given nor liability assumed with respect to the identity of any party named or referred to in Schedule A
or with respect to the validity, legal effect or priority of any matter shown therein.
2. The Company's liability hereunder shall be limited to the amount of actual loss sustained by the Assured because of
reliance upon the assurance herein set forth, but in no event shall the Company's liability exceed the liability amount
set forth in Schedule A.
Please note carefully the liability exclusions and limitations and the specific assurances afforded by this guarantee. If you
wish additional liability, or assurances other than as contained herein, please contact the Company for further information
as to the availability and cost.
Chicago Title Insurance Company
By:
Chicago Title Company of Washington
3002 Colby Ave., Suite 200
Everett,WA 98201
Randy Quirk, President
saw
Countersigned By: { �� . Attest:
SN I 0
` AX
i
•.:. Marjorie Nemzura, Secretary
Brent Aune
Authorized Officer or Agent
Received
SEP 0 8 2021
Subdivision Guarantee/Certificate Printed: 10.22.21 @ 02:43 PM
Page 1 WA-CT-FNRV-02150.624691-SPS-1-21-500128087
OFFICE COPY
CHICAGO TITLE INSURANCE COMPANY GUARANTEE/CERTIFICATE NO. 500128087
ISSUING OFFICE:
Title Officer: Builder Unit
Chicago Title Company of Washington
3002 Colby Ave., Suite 200
Everett,WA 98201
Fax: (866)827-8844
Main Phone: (425)259-8223
Email: evebuilder@ctt.com
SCHEDULE A
Liability Premium Tax
$0.00 $0.00 $0.00
Effective Date: October 8, 2021 at 08:00 AM
The assurances referred to on the face page are:
That, according to those public records which, under the recording laws, impart constructive notice of matter relative to
the following described property:
SEE EXHIBIT "A"ATTACHED HERETO AND MADE A PART HEREOF
Title to said real property is vested in:
Stilly 3, LLC, a Washington Limited Liability Company
subject to the matters shown below under Exceptions, which Exceptions are not necessarily shown in the order of their
priority.
END OF SCHEDULE A
Subdivision Guarantee/Certificate Printed: 10.22.21 @ 02:43 PM
Page 2 WA-CT-FNRV-02150.624691-SPS-1-21-500128087
EXHIBIT "A"
Legal Description
For APN/Parcel ID(s): 004554-005-016-00 IOP
LOT 18, BLOCK 5, GIFFORD'S FIRST ADDITION TO ARLINGTON,ACCORDING TO THE PLAT THEREOF
RECORDED IN VOLUME 2 OF PLATS, PAGE 66, RECORDS OF SNOHOMISH COUNTY,WASHINGTON.
SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON.
Subdivision Guarantee/Certificate Printed: 10.22.21 @ 02:43 PM
Page 3 WA-CT-FNRV-02150.624691-SPS-1-21-500128087
CHICAGO TITLE INSURANCE COMPANY GUARANTEE/CERTIFICATE NO. 500128087
SCHEDULE B
GENERAL EXCEPTIONS
A. Rights or claims of parties in possession, or claiming possession, not shown by the Public Records.
B. Any encroachment, encumbrance, violation, variation, or adverse circumstance affecting the Title that would be
disclosed by an accurate and complete land survey of the Land.
C. Easements, prescriptive rights, rights-of-way, liens or encumbrances, or claims thereof, not shown by the
Public Records.
D. Any lien, or right to a lien, for contributions to employee benefit funds, or for state workers'compensation, or
for services, labor, or material heretofore or hereafter furnished, all as imposed by law, and not shown by the
Public Records.
E. Taxes or special assessments which are not yet payable or which are not shown as existing liens by the Public
Records.
F. Any lien for service, installation, connection, maintenance, tap, capacity, or construction or similar charges for
sewer, water, electricity, natural gas or other utilities, or for garbage collection and disposal not shown by the
Public Records.
G. Unpatented mining claims, and all rights relating thereto.
H. Reservations and exceptions in United States Patents or in Acts authorizing the issuance thereof.
I. Indian tribal codes or regulations, Indian treaty or aboriginal rights, including easements or equitable servitudes.
J. Water rights, claims or title to water.
Subdivision Guarantee/Certificate Printed: 10.22.21 @ 02:43 PM
Page 4 WA-CT-FNRV-02150.624691-SPS-1-21-500128087
CHICAGO TITLE INSURANCE COMPANY GUARANTEE/CERTIFICATE NO. 500128087
SCHEDULE B
(continued)
SPECIAL EXCEPTIONS
1. No search has been made as to property taxes and assessments. Property taxes and assessments will be
searched upon request.
2. Covenants, conditions, restrictions, recitals, reservations, easements, easement provisions, dedications, building
setback lines, notes, statements, and other matters, if any, but omitting any covenants or restrictions, if any,
including but not limited to those based upon race, color, religion, sex, sexual orientation,familial status, marital
status, disability, handicap, national origin, ancestry, or source of income, as set forth in applicable state or federal
laws, except to the extent that said covenant or restriction is permitted by applicable law, as set forth on the Plat of
Gifford's First Addition to Arlington:
Recording No: 189008215001
3. Covenants, conditions, restrictions, recitals, reservations, easements, easement provisions, dedications, building
setback lines, notes, statements, and other matters, if any, but omitting any covenants or restrictions, if any,
including but not limited to those based upon race, color, religion, sex, sexual orientation,familial status, marital
status, disability, handicap, national origin, ancestry, or source of income, as set forth in applicable state or federal
laws, except to the extent that said covenant or restriction is permitted by applicable law, as set forth on Survey:
Recording No: 201503245002
4. A deed of trust to secure an indebtedness in the amount shown below,
Amount: $1,627,533.00
Trustor/Grantor: Stilly 3, LLC, a Washington Limited Liability Company
Trustee: Reconveyance Professionals
Beneficiary: Homestreet Bank
Recording Date: September 9, 2021
Recording No.: 202109090911
Affects: includes other property
5. The Company's liability for this report is limited to$1,000.00. This report is based on the company's property
records, and no liability is assumed for items misindexed or not indexed in the public records, or for matters which
would be disclosed by an inquiry of the parties in possession or by an accurate survey or inspection of the
premises. This report and the legal description given herein are based upon information supplied by the applicant
as to the location and identification of the premises in question, and no liability is assumed for discrepancies
resulting therefrom. This report does not represent either a commitment to insure title, an examination of, or
opinion as to the sufficiency or effect of the matter shown, or an opinion as to the marketability of title to the
subject premises.
END OF SCHEDULE B
Subdivision Guarantee/Certificate Printed: 10.22.21 @ 02:43 PM
Page 5 WA-CT-FNRV-02150.624691-SPS-1-21-500128087
N " RESIDENTIAL PERMIT APPLICATION
® Department of Community & Economic Development
, Cs�� City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551
THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE,
ADDITION, DECK, OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS
OF CONSTRUCTION DRAWINGS AND TWO(2)SETS OF STRUCTURAL CALCULATIONS. THE APPLICATION MUST
ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS. THE ZONING
VERIFICATION MAY BE SUBMITTED PRIOR.
Pro ect Address: %XX Stillaguamish Ave,Arlington WA (. o Plat: Giffords 1st Addition to Arlington
j _
u G N {,`Q-V O�d1tN1
Single-family ❑ Duplex ❑ Townhouse U Addition ❑ Accessory structure
Proposed Area: 15` Floor: 1107 SF 2nd Floor: 1058 SF Garage:370 SF Total SF: 2535 SF
Describe Proposal (include cross street):
Construction of a single family residence located on Stillaguamish Ave. The underlying address is 116
Stillaguamish Ave. There is 3 legal parcels are under that address. New addresses will be necessary.
Valuation: 1 C_.® 0_
Owner: Stilly 3 LLC
Address:10211 180th St SE _ _City: Snohomish State:WA Zip Code: 98296
Phone: 425.361.5914 _ Email: acmekristi@gmail.com
Applicant: Acme Homes LLC /Attn Robert B Cumming
Address: 10211 180th St SE _City. Snohomish State: WA Zip Code: 98296
Phone: 425.361.5914 Email: Acmekristi@gmail.com
Contractor: Acme Homes LLC
Address: 10211 180th St SE City:Snohomish State: WA Zip Code: 98296
Phone: 425.361.5914 Email: acmekristi@gmail.com
Kristi K le ACMEHHL859RC 12/03/2021
Contact Person: y License Number: Expiration:—
Received
SEP 0 8 2021
'BI_D - y215
6116LP Page 1 of 3
0DI-muto
RESIDENTIAL PERMIT APPLICATION
Department of Community & Economic Development
City of Arlington• 18204 59th Ave NE•Arlington, WA 98223 • Phone(360)403-3551
Plumbing Section (continue filling out if plumbing is involved)
(Check all that apply and indicate the number of fixtures proposed)
KITCHEN
❑ Bath/Shower Combo (4.0) x 2 ❑ Sink (1.5) x 1
❑ Shower (2.0) x 1 ❑ Lavatory (1.0) x 5
❑ Clothes Washer (4.0) x 1 ❑ Water Closet (2.5) x 4
❑ Dishwasher (1.5) x 1 Water Heater x 1
CI Hose Bibb (2.5) x 2 Water Heater Model #
❑ Other (list) x
Plumbing Section Continuedj
Proposed Water Piping Size: `inch Proposed DWV Material: t{aj�+
Proposed Piping Material �G� Proposed DWV Size: _
• All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019
• All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV)
6/16LP Page 2 of 3
Y °� RESIDENTIAL PERMIT APPLICATION
• Department of Community & Economic Development
City of Arlington• 18204 59th Ave NE •Arlington, WA 98223 - Phone(360)403-3551
Mechanical Section (continue filling out if mechanical equipment is involved)
Select proposed appliances:
❑ Furnace (80+) Model# AFUE Qp
Heat Pump Model # t`i1 X2'3Cat-\Nf)1H2a 44SEER 20.0 �SP 10.0
❑ AC Unit Model# — SEER
❑ Type II Hood ❑ Commercial Cooking Appliance ❑ Hydronic Piping
❑ Boiler ❑ Solid-Fuel Appliance ❑ PV System
Fireplace Insert ❑ Outdoor BBO ❑ Storage Tank
❑ Freestanding Stove TA Gas Piping ❑ Other -
Gas Piping Information
Not Applicable: F_J 66 (4 Q.l006A
�� � 1�0
Pipe Material: Pipe Size: _ l Total BTU's of all Appliances: 3D.100 N - __
Distance from Meter to Furthest Appliance:
+/-60 feet
• New gas piping requires a pressure test to hooking to any appliance
• Sediment traps (drips) are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
• Proper combustion air and venting required for all appliances
• A shut-off is required within 6 feet of all appliances
Applicant Signature: _ - __-- Date
Robert B Cumming
Print Applicants Name:
6/16LP Page 3 of 3
CITY OF ARLINGTON
18204 59th Avenue NE,Arlington,WA 98223
INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551
BUILDING PERMIT
124 N STILLAGUAMISH AVE Permit#: 4215
PERMIT EXPIRES 180 DAYS AFTER
Parcel#: 00455400501600 DATE OF ISSUANCE.
Scope of Work: Construction of new SFR Valuation:403779.00
OWNER APPLICANT CONTRACTOR
116 STILLY LLC Stilly 3 LLC Acme Homes
903 200TH ST NE 10211 180th St SE 10211 180th St SE
ARLINGTON,WA 98223 Snohomish,WA 98296 Snohomish,WA 98296
425-361-5914/425-361-5914 425-361-5914
LIC:ACMEHHL859RC EXP: 12/03/2021
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
LIC#: EXP: LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Single Family Residence CODE YEAR: 2018
STORIES: 2 CONST.TYPE: VB
DWELLING UNITS: I OCC GROUP: R-3
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any
other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the
Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any
period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance
advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building
official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this
jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,
guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is
determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City
ordinance,regulation or order, state or federal law,or any order,proclamation,guidance or decision of the Governor.
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK
AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE
OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND
ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN
MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRCI10.
SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on
your sales tax return form and coded City of Arlington#3101.
L6
Signa ure Print Nam& Date Released By Da c
CONDITIONS
-The gable vents should match the( ,m of the building and be located on both the. t and back sides of the house.-Blower
door test required.-Duct test required. -All downspouts must be directed into infiltration trenches per standard detail SD-140-
Driveways must be paved,drainage for driveways shall be provided and managed onsite.-If the alley is not paved adjacent to
these 3 lots,it must be paved as part of this work.Adhere to approved plans and red lines.Approved plans and permit shall be
onsite during construction.Call for inspections.
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE
PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS,DRIVEWAYS,
MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
11/24/2021 Building Permit $4,052.52
11/24/2021 Park-Community SF $1,662.00
11/24/2021 Park-Mini SF $484.00
11/24/2021 Processing/Technology $25.00
11/24/2021 Building Plan Review $2,634.14
11/24/2021 State Surcharge-1st DU $6.50
Total Due: $8,864.16
Total Payment: $0.00
Balance Due: $8,864.16
CALL FOR INSPECTIONS
Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
Permit#: 4215
Permit Date: 10/26/21
Permit Type: RESIDENTIAL SINGLE FAMILY
Project Name: Stilly 3 Lot 18
Applicant Name: Stilly 3 LLC
Applicant Address: 10211 180th St SE
Applicant, City, State, Zip: Snohomish, WA 98296
Contact: Robert Cumming/Chris Eddy
Phone: 425-361-5914/425-508-9968
Email: chris.eddy@acmehomeswa.com
Scope of Work: Construction of new SFR
Valuation: 403779.00
Square Feet: 2535
Number of Stories: 2
Construction Type: VB
Occupancy Group: R-3; Residential
ID Code:
Permit Issued: 11/24/2021
Permit Expires: 05/23/2022
Form Permit Type:
Status: COMPLETE
Assigned To: Raelynn Jones
Property
Parcel# Address Legal Description Owner Name Owner Phone Zoning
124 N STILLAGUAMISH 100 SINGLE
00455400501600 AVE It 6 STILLY LLC FAMILY
RESIDENCE
Contractors
Contractor Primary Contact Phone Address Contractor Type License License#
Acme Homes Kristi Kyle 425-361-5914 10211 180th St CONSTRUCTION L&I ACMEHHL859RC
SE CONTRACTOR
Inspections
Date Inspection Type Description Scheduled Date Completed Date Inspector Status
02/03/2023 R20.SFR/DUPLEX Final 02/06/2023 02/06/2023 BUILDING Approved
FINAL
02/01/2023 Inspection Infiltration 02/02/2023 02/02/2023 BUILDING Approved
Plan Reviews
Date Review Type Description Assigned To Review Status
10/26/2021 RESIDENTIAL SINGLE BUILDING
FAMILY
RESIDENTIAL SINGLE Building Permit Condition:The gable vents should match
10/26/2021 FAMILY the design of the building and be located on both the front PLANNING
and back sides of the house.
Fees
Fee Description Notes Amount
Building Permit Table 4-1 $4,052.52
Park-Community SF Single Family $1,662.00
Park-Mini SF Single Family $484.00
Processing/Technology $25.00
Building Plan Review Table 4-2 $2,634.14
State Surcharge- 1st DU Residential- 1st Unit $6.50
Total $8,864.16
Attached Letters
Date Lcttcr Description
11/24/2021 Building Permit
Payments
Date Paid By Description Payment Type Accepted By Amount
11/24/2021 Stilly 3 LLC 2257 Raelynn Jones $8,864.16
Outstanding Balance $0.00
Notes
Date Note Created By:
11/05/2021 New Property Address: 124 N Stillaguamish Avenue Amy Rusko
10/26/2021 Add Planning and Civil comments from Zoning Verification to permit Raelynn Jones
10/26/2021 Credit for Arlington SD Mitigation fees for this lot for existing SFR Raelynn Jones
Uploaded Files
Date File Name
11/24/2021 10188894-4215 Issued Permit.pdf
10/26/2021 9977873-4215 Application.pdf
Date: 03/13/2026
Permit#: 4215
Permit Date: 10/26/2021
Review Date: 10/26/2021
Permit Type: RESIDENTIAL SINGLE FAMILY
Review Type: RESIDENTIAL SINGLE FAMILY
Target Date: 11/23/2021
Scheduled 00:00
Time:
Completed 11/05/2021
Date:
Description: Building Permit Condition: The gable vents should match the design of the building and be
located on both the front and back sides of the house.
Review Status:
Assigned To: PLANNING
Time In: 00:00
Time Out: 00:00
Hours: 0.0
Notes
11/05/2021 Address in Notes.
Property Information
Parcel#: 00455400501600 116 STILLY LLC
116 STILLY LLC 903 200TH ST NE
124 N STILLAGUAMISH AVE ARLINGTON, WA 98223
Zoning: 100 SINGLE FAMILY
RESIDENCELot: 18Block: 5
WRITTEN DIMENSIONS ON TIIG DRAWING GIL4LL NAVE P ON5—NCE OVER 770 DIMBJSIONS.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS,CONDITIONS,ETV.PERTAINING r0 THE WORK
BEFORE PROVEEDINS.TIE!OWNER MST BE NOTIFIED OF ANY VARIATIONS FROM THE
DIMENSIONS AND/OR LONDITONS SHOVN ON TIESE DRAWIN65.ANY SI1GH VARIATION A EE
RESOLVED Br TIE OWNER PRIOR To PROCEEDING WITH TIE WORK,OR THE VONiRAVTOROR SNALL
ACCB'T FULL RESFOh9181LITY FOR n IE C05T TO RECTIFY SAhE.
I RE�IHTEl*m
2X5 BARGE BOARD
- - W/IX2 TRIM - - -
HEIGHT OF 97RUGTURE
BOARD AND BATTEN
2 51DING-IX5 BATTEN5
HORIZONTAL 5IDING 8 O 16"O.G. PLYWOOD
OR HARDI-PANEL BEHIND
WHERE SHOWN .,
... UPPER FLOOR P.L. W a
4 INCH WINDOK'DOOR
TRIM TYPICAL ALL - IX4 CORNER O ,3
FOUR SIDES UNLESS jYa
OTHERWISE NOTED /
METAL ROOFING
®FRONT PORCH _ _ _ FIN.PLR.UPPER
MAIN FLOOR P.L. ¢>i7
(S.aJ
T
T
PIN.PLR MAIN
J
J
H
W
FRONT 'S' �= o
NOTES: SEE GENERAL NOTES SCALE`., 1/4" I'-O" = Z
I. ALL WOOD EXPOSED TO WEATHER
SHALL BE PRESSURE TREATED, SQUARE FOOTAG�S W O
.CEDAR OR PAINTED c
MAIN 11 0-1 J/ib�
Z.CAULK AND SEAL ALL WINDOW/DOOR UQP�R IOSS V m
AND EXTERIOR EV NELOPE TOTAL 265 _
PENETRATIONS.
5.GLAZING PER STATE ENERGY CODE. GARACGE 570
4.PROTECTION FROM DECAr 15 RE(MUIRED FOR ALL GOB/-Rr 108
�"OAE50VEOD 'Ne CONCRETE AND VqALL STEPSAPORGHE55 5LAB5 N PORCH
PATIO SLABS,AND SIMILAR HORIZONTAL 51JRFAGES
EXPOSED TO THE WEATHER y
5.REFER TO ALL ELEVATIONS FOR ADDRESS NOTE:
TYP IGAL NOTES. ADDRESS NUMBERS SHALL BE tn
6.S.G. - 5AFETr GLAS5 A MINIMUM 4"HIGH WITH A Z
MINIMUM STROKE WIDTH OF I/1" Z
AND TO BE ON A CONTRASTING
BACKGROUND PER IRG 51-1.1 (V O O
UPPER FLOOR P.L. Il W
lL n
L- L
m d
data:
permit,
FIN.FUR.UPPER rOVlelone:
MAIN FLOOR P.L.
�}C��• �v�„y6� Voot�
v VLJ `E5r drawn by LMD
Gheckad by. MWJ
J
- - - FIN.FLR.MAIN
Q
FIN.FLR.6ARA6E 1 FOYER N OFFICE COPYAk
�� 8
CITY OF ARLINGTON
REAR. 1=—LE\/A7ION BUILDING DEPARTMENT
SEE GENERAL NOTES SCALE, I/4" I'-O" APPROVED *** ***•"***'**•*******^'
DATE_� Bv_�_ Plan Review
By
NO CHANGES AUTHORIZED City ofAdington
UNLESS APPROVED BY THE
BUILDING INSPECTOR ***********xxxxxxxxxx**xxx
SEP�8,:ii21
� eAew�r1io n P I�•�ng
WRITTEN DIMEN51015 d THIS DRAWING 5NA1L NAVE PRELEDENLE d✓ER SLALID DIMENSIONS.
GONTRALtOR SHALL VERIPY ALL DIMENSIONS,LONDITIONS,ETL.P32TAININ6 TO TE WORK
Dl F l PRCLEEDINS.TIE OWIEFt 1—BE NOTIFIED GF ANY VARIAtIONS FROM TE
DIMENSIONS NJD/OR LONDITIONS 5HOWN ON TIESE DRAWINGS.ANY YGH VARIATION SHALL BE
REsoLVEo er rNE owER PRIOR ro PRaEEDINz wITH nE wLRK,aR n+E.oNrRALroR sNAu
' AL:.EPf Ps..RE�cNs;elutt FaR TrE cosr to RELnFr snrE
I2X5N I BARGE BOARD
VV �'L�wRYle
X2 TRIM — — —
HEIGHT OF STRUCTURE
12 5HN16LE ■
HORIZONTAL 51DIM, b SIDING WHERE
WHERE SHOWN SHOWN ..
[� m
UPPER FLOOR P.L. -
4 INCH WINDOW/DOOR
TRIM TDIGAL ALL IX4 CORNER 7 ry O H
FOUR SIDES UNLESS
OTHERWISE NOTED
METAL ROOFING
a FRONT PORCH _ _ _ _ FIN.FLR.UPPER
MAIN FLOOR P.L. ��I D
�� 7 w
P
4/1 ,/1
u
FIN.FLR.MAIN
V
J
J
W
FRONTON 'C.,' es- 2 0
NOTES: SEE GENERAL NOTES SCALE: 1/4" = 1'-0"
I. ALL WOOD EXPOSED TO WEATHER Z
SHALL BE PRESSURE TREATED, SQUARE 'FOOTA6ES `y Q
-CEDAR OR PAINTED
MAIN
2.CAULK AND SEAL ALL WINDOW/DOOR IO-I ■ m I
AND EXTERIOR ENVELOPE UPPER 1055
PENETRATIONS.
TOTAL :2165
,. 5.GLAZING PER STATE ENERGY GORE. GARAGE S-IO
4.PROTECTION FROM DECAY 15 REOUIRED FOR ALL GO�/ERED Ice,WOOD SIDING W L AND AL FRAMING LESS THAN
2"ABOVES CONCRETE STEPS,PORCH SLABS, 1 PORGi--V 1 - ■ ■
PATIO LABS,AND 51MILAR HORIZONTAL 5URFAGES
EXPOSED TO THE WEATHER
5.REFER TO ALL ELEVATIONS FOR ADDRESS NOTE:
TYPICAL NOTES. v
ADDRESS NUMBERS SHALL BE it in�
6.5.G. = SAFETY&LASS A MINIMUM 4"HIGH WITH A
MINIMUM STROKE WIDTH OF 1/2" z
AND TO BE ON A GONTRA5TING
■ BAGKCROUND PER IRG 51-1.1 ■ /�■ O 6
� W z
UPPER FLOOR P.L.
0
- L
10 Q
■
- data: 6-�8-21
pormlt:
FIN.FLR.UPPER ravlslons:
MAIN FLOOR P.L.
Q drawn by: LMD
is SJ chockod by: MWJ
FIN.FLR MAIN A I •
O
FIN.FLR.GARAGE i FOYER ry O
REr%R ELEVA710N
SEE GENERAL NOTES
■
kk k«k*kk«xxxkxxk«« 1an Review
BY
I I k«City of Arlington
kkkk«««kkk«kkik
L
W 1—DIMENSIONS ON TNI9 DRAWINS SHALL HAVE FREGEDENOE OVER SEALED DIMEN510N5.
LONiR.ALTOR 51441E VERIFY ALL DIMENSIONS,NOTIFIED
F A ETC.PERTAINING TO Tlff WORK
BEFORE PROOEEDING.THE Oh MUST BE NOTIFIED OF ANY VARIATIONS FROM Tiff
DIMENSIONS Alm/OR LONDITIO FOR
SHOWN ON T1E5E DRAYVIN65,ANY 511DH VARIATION SHALL BE
_. RESOLVED BY T1ff OWNER OR R R FFOG TO T TO
Tiff WORY�.W OR TIE GONTRAOTOR SHALL
ACCEPT PULL RESFON5IBILITY FOR THE L05T TO REOTIPY SA1E.
1 /,IL R�IlTGRBD
I` RGHITGGT
—METAL FASCIA W TER r7,�
UPPER FLOOR P,L. ��I{ �
Pj
FIN.
9L
it
r
R
PIN.FLR.MAIN
Q — — — — — FIN.PLR.MAIN
tV FIN,FLR.bARA6E 1 FOYER J
y
5W
Lr=PT ELEVATION = z
- SEE GENERAL NOTES SCALE: 1/4" . I'-O" W O
m
V �
4
ASPHALT COMP.SHINGLES
ON I-FELT
Ln
-- z
= �C >
—_ __
UPPER FLOOR P.L. _ -A w
— permit)
PIN.RR UPPER - __ - - -- rovlelone:
MAIN FLOOR PL.
chockee by, MWJ
LKI'Llt.MAIN
O�
�v
RIGHT ELIEVA7I0N
SEE GENERAL NOTES SCALE: 1/4"
«««Plan
By
City ofArlington
WRITFEN DIF@NSIdK ON THIS DRAWING SHALL HAVE FRELEDENCE OVER SCALm DIMENSIONS.
CONTRPGTOR SHALT.VERIFY a1L DIMENGIONS,LOIIDITOIG,ETC.PERTAINING TD TB WORK
BORE PROCEFDING.11£OWN9x M.5T BE NOIIFIm of ANY VARIAT015 FROM TIE
DIMEN510Ns AND/GR LONDITOFG 5H04N ON T£SE ORAWIN6s.ANY 51.GH VARIATION 5HPLL�
RESOLVED BY Tf£OMPER PRIOR TO F'RCCEEDIN6 WITi T$WORK,OR nff CONTRACTOR SHA1 I.
" K EFT FILL RE�c`1LiEILITY FOR T£COST TO RECTIFY�v.
- ���a�rJF.TIIe
Tt E
METAL FASCIA&UTTER
UPPER FLOOR P.L.
�/ /i❑ � rT�, g o❑ ❑ W S
- - -
FIN.FLR_UPPER
MAIN FLOOR P.L.101
C
P
I
FIN.MR.MAIN FIN.FLR.MAIN J
_j
tN FIN.FLR.6ARA&E<FOYER W
O ❑
SEE GENERAL NOTES SCALE: 1/4" = 1'-O" W
um
ASPHALT COMP.5HIN&LE5 J
ON I5M FELT ^ nl
i , ��r
L '^Z`
Z
� „ z
UPPER FLOOR P.L. Ctu
P�l 117/1111 . L
Y 0
iL
date: 6-28-�I
permit:
revis Ions:
FIN.FLR UPPER ---
MAIN FLOOR PL. - - - - - - - - - - - - - - -
ls,v y
"' HH
i4i4 - �hecked by: MWrI
L",R
MAIN --
O�
�v
R I CSH-7 ELIEV'AT I ON
SEE GENERAL NOTES SCALE: 1/4" P-O"
>..*Plan*Review******
By
City of Arlington
lYA1TRN DIMENSIONS ON T115 OR NEH1, SHALL NAVE PRECEDENCE OVER SVALED DIMENSIONS.
CONn7ACTOR SHALL VERIFY ALL DIMENSIONS,T FI DIT F ETV.P 1ATA 1,15 F TO TiE WORK
EEPORE P ANp/IIIS.THE rkwe s ktAN BE NOTIFIED OF ANY VARIATIONS FROM,ff
DIMENSIONS AND/OR COIB)ITI Im T OWI ON TffSE DRAWINGS.ANY SUCH VARIATION SHALL BE
RESOLVED ST THE OWIER PF21CR TO FROCEDINS WTI TIE CR TIE CONTRPCTOR SHALL
ACCEPT FALL RESPONSISILITT P'OR TiE LOST ro RECTIFY SAMEME.
251-0" �TI miHi
9 ERCD
6'-0" IQ'-0' TEcr
-0' M-3
3 S 3 S
4 LA < LA
T14
I—— S —, ----- TO ————————
NGRETE N.FOTING
FOOTINISS e O.H.DCOR
1 1 -�IY
Tr II W1�1
a
I I I III���111
4 e P.T.
a 6"2Xb LEDGER P, • I Ib FIT JOISTS
in W,5DW5 SCREWS 3x\.� OZ. /4 <• I C/
4'GONG.SLAB ON
4"GRANULAR BED
ON STAMPED GRADE I I 4 U
TABLE A307.8.1.3(2) — SLOPE 3"TO O.H.OR
PLACEMENT OF LAG SCREWS AND BOLTS IN DECi(LEDGERS AND BAND JOISTS
MWIMUM END AND EDGE p19TANCE8 AND 9PACING BETWEEN ROWB RpW 9PACING 1
BOTTOM EDGE
ioP EDGE /°inch 2inches" la/a inches° GARAGE SLAB TO
Ledger 2inches N BE STEPPED DOWN
Bend J016[°
inch 2 inches 2inches" I'/e inches° F = 2'FTtOM MAIN F.F. r L
For Si:linch=zSA men. FOYER F.F.TO
F.Leg xinch or bolts shell be amggered from[M1e top m the bmtom along the hodmntel ran of the dak ledge in accordanm wiN Figure R50]9.1.3(11. STEP DOWN 2' I I I
b.Muimum 5 inches. FROM MAIN F.F. I —
c.
12'-4"
Forengirwarw dmioiab.ths menufac,i Mcormnandati—shall 9ovem. I I
d.The minimum dismnm from bottom row of leg acmws or bale m the top edge of Ne ledger shell be in accordance wiN Figure R507.9.1.3(I 1. — r J
STAGGER FASTENERS (2)2x12
Ng IN 2 ROWS _ ry 7-7)
J55"MIN.FOR 2 X S' 'DISTANCE SHALL BE PERMITTED TO J® ® ® 8.5"MIN.FOR2X10BE REDUCED TO 4.5"IF LAG SCREWS 6"C+ONG.F'OUNDA ION WALL
7,V MIN.FOR 2 X 12 ARE USED OR BOLT SPACING IS T I - I L y
® ® ® REDUCED TO THAT OF LAG SCREWS
TO ATTACH 2 X B LEDGERS TO 2 X 8 GON TING W
/ BAND JOISTS. y6)— ____
2-MIN. / 3 B■
LAG SCREW OR BOLT 3/4"MIN.
LEDGER
For SL linch 254 n.�ii. m
\ I —
Figure 14.General Attachment of Ledger Board to Band Joist or Rim Joist .JC"• \ '� W 0
remove siding at ledger !A1 — =
exterior sheathing prior to installation (2)2XI2 O m
threshold mremlly Flashed and 31 STAIRS ABv. 4 Gi2AYVL SPACE
existing stud-11 osulked to prevent water intension /' "'
ledgerand joist Mush ontm./� \ I6RIL. F bMIL.BLACKVAPOR
existing 2x band Joist continuous ashlng ry I _ GRWL. �. BARRIER TO TOP OF FTC.
g I SPADE W/I2"LAP a ALL SEAMS n
or 1"minimum Isaarlding Past joist ACCESS Iz 4x4 P.T.POST(4xb 0 BEAM_
EWP rim Jolet hanger ` I _ _ __.IN5.61N_5 N
deck joist _ 5PLIGES)ON 90rs FELT ON
2"min. IS"xlb"xl0"GONG.FTC.U.NA.
1-5/a"min. — — -
5"max. 1/2'diameter lag
2"min. screws or — — — — — —
2x floor Joist, through-bobs with T
wood I-joist.
washers ———— - —or MPCWT .. _ 3x- _——— -
a joist hanger '0
• P1-� Tx_ _ — i ^
existing 2x ledger board:must be greater / STUDS 2x12 FLR.J015T5
wall than or equal to the depth of the 1<i — 4 PLATES16'O.G.
deck joist and no greater than the
depth of the house band or rim joist L
�•\ — — — — — �� 4 PLATES
a I
SHEAR NOTE:
I.S%MATERIAL GAN BE USED FOR ..
ALL MUDSILLS _ _ _ _ 4•%24"x10"
2.SET A DOUBLE 2X STUD BEHIND �6 POST
EVERY 5THDI4 HOLDOWN GALLED OUT
U
ON THE FOUNDATION PLAN.SET HOLDOWN
1/2"MINIMUM AWAY FROM WALL CORNERS, .�
WINDOW AND DOOR HEADERS.IT 15 IMPORTANT _ 4 O
THAT THE FOUNDATION CONTRACTOR HAS THE
LAIN OHORR PLAN
N5.SHEET TO PROPERLY
S.A MST45 STRAP WITH(2)1/2"BOLTS INTO — — — — — — —
THe FOUNDATION 15 A PROPER PIX FOR
A MISPLACED 5THDI4 HOEDOWN.
NOTES. i — — — — — — —L—_J — — I revlS Ions:
ALL WOOD IN CONTACT WITH CONCRETE a1
SHALL—PRESSURE TREATED OR CEDAR. — — — — — —
PROVIDE CRAWL DRAIN s LOW POINT I T
IN GRAWLSPAGE. I6•X6'%1D'
50LID BLOCKIN&UNDER ALL BEARINS WALLS. S
5LOPE ALL GONG.STOOPS AND/OR PATIOS
1/4"PER FOOT AWAY FROM DOORWAYS.
BEARINb WALL ABOVE
P.T.2xb LEDGER drawn by LMD
ro N.7�p �FOUNDATION VENT CALCULATION 0 —00 I y'
110-1 SQUARE FEET 3.6G I I FDTN,VENTS, SIDE=�T
500 .57 Q 9° — — — — I 16 x�6 SCREENE
-7 VENTS REOUIRED 7 A B
4',1}LIO 4 O r I
SHEAR NOTEr b ------P}j•�'— — i7 —PZ-4•— /T----y _pia_ T
O
SEE SHEET LI FOR SHEAR WALL NQ(Y) Q A' a PLATES S ' S y-h
NAILING SCHEDULE, 4 DETAILS.
I6'WIDEX6'
ES
THICK C.ONTIN)dY
HOLDDOINN SCHEDULE CONCRETE STRIP
FOOTING
MARK HOLDOWN/ FASTENERS WOOD MEMBER ANCHOR
STRAP THICKNE55/SPEGIES RECIUIRED
T-1 STH014/14 RJ 24-I6d SINKER (2)2X4/2Xb STUDS 6'-0' 4'1• 12'-b"
HP/5PP
T-2 MST48 (34)-Ibd (2)2X4/2Xb STUDS 25'-0•
HF/SPF
T-3 MSTA56 (26)-I Od HF/SPF(2)2X4/2Xb STUDS O U N=7 A T 1 O N PLAN
T-4 MSTG48B3 (58)-IOd HF/5PP SEE bENERAL NOTES SCALE: I/4" I'-O" .: xxxxxxxxxxxxxxxxxx«««xxPlan Review
T-5 HDUb-SDS2.5 (20)5D5 I/4" 4xb POST 7/5"ANCHOR
BOLT B
X 2-I y
City of Arlington
z-.txxxxxxxxxxxxxxxxxxYeerMR —--
e0irT
cNSHALL VER FY�L DIMENSION5,NLONDIT ON5,ETC. EAININS TOTODTHEI
col—CTOR WORK
BEFORE PROCE]JIHG.THE OWNER MUST BE NOTIFIED OF ANY VARIATIONS PROM TVe
DIMENSIONS AND/OR CONDITIONS SHOYN ON THESE DRAWINGS.ANY SUCH VARIATION 5f1ALL f3E
FEa x_V D BT TIE oHNS'PRIOR TO PROCEEDING WITH THE WORK,OR THE(ANTRACTOR SHALL
A cI ei L RESPONSIBILITY FOR TFe COST TO RECTIFY
25'-0"
�I~IX�V9-Y'LL.YIJG
4'-0" 2'-0" '"4�" 1615" '-42
}• I A•
SA ! SA
16050 O.H.GARAGE DOOR
I I
Q o iGP0'; ,
O W
I PLATES� L----- LINE OF O_H.DOOR -------
IN UPRIGHT POSITION ���111 t�••I
NOTE5, F bARA6E
F'LP
ALL EXTERIOR WARM ALLS TO BE
W
2 x 6 5TUD5-
WALLS TO Be IaadIIH111111
2 x 4 STUDS O 24"O.G.TYPICAL.
ALL HEADERS TO BE 4 X 10 OP*2 O
UNLESS NOTED OTHERWISE. �\ 2 6 fV
PUR-OUT HEADERS TO MATCH 2 X 6 2O MIN. -
SELF V.2"
WALLe. L051
ALL EXTERIOR HEADERS MUST BE LINE OF LOOK ABOVE
INSULATED WITH R-10 INSULATION PER W5EG -... _ 3"STEEL
iQnb MUDROOM J up
BOLLARD
FOR WINDOWS WITH OPERABLE OPENINGS MORE - Lpl „EAT0 v MINIMUM
THAN"12'ABOVE THE FINISHED BRAD OR Sl1RFAGE UP 4
BELOW,THE LOWEST PART OF THE CLEAR OPENING RISERS DETECTOR B
SHALL BE 24"MINIMUM A50. 1!THE FLOOR.FXGEPTIONS, 0 LEr
FULLY OPEN WINDOWS WHERE A 4"SPHERE MAY NOT �\
PASS THROU&H OR WHERE PALL PROTECTION DEVICES T T
ARE PROVIDED PER ASTM P 2090 OR R612.3 tL PI-4•
SOLID SLOGKlN UNDER ALL BEARING
WALLS.
TUB/SHOWER UNITS SHALL HAVE FIRE O 0
BLOKING BETWEEN ALL 5T1 D5 AND Ih
D J
WATERPROOF SURROUNS TO a-12" 3,�n m J
C WE
FROM DRAIN. &LAZING,INCLUDINb MASTER LVTNO mH Q"o" i
WINDOWS WITHIN•1 "OF DRAIN, N N y
SHALL BE 5APTEY&LA59. SHOWER d N g i
FLOW IS LIMITED TO I.15 6AL/MIN. BATH `�U 50 GFM W
50 GFMuj
EXHAUST FANS LARGER THAN-PM MAY BE j�. ry N 4
CONNECTED TO 4'SMOOTH WALL VENT PIPE / •Op •■
FHERU�.NI�S DO NOIZTeEXCEELLD 20'UUIGCN LENbTH. m ---- a1 O
DIAMETER WITH A MAXIMUMDRVN C �9' N AN \
y N TO
COMBUSTION AIR REQUIRED FOR ALL I 5O m
FUEL BURNING APPLIANCES r 8 POWDER % *N LINEN ry C in
LEGEND. Y N<• 6RWL,� O O /
IIOV Sc. 2860
BEARINb WALL / 6 m S SPACE
m
j ACCESS 3'-6" B
BEARINb ABOVE
FLOOR LINE ABOVE abe roAEed with ana fel light source to Q 4-0" i !
R303.7 Interior stairway illumination.Interior staff P 9 v tV ;Q
LD..i
POINT LOAD ABOVE .D r
AI3V. illuminate the landings and treads.Stairway illumination shall receive primary power frnm the building wiring.The m
--- --pppC MULTIPLE 2.STUDS light source shall be capable of illuminating treads and landings to levifls not less than 1 Foot-
o POINT LOAD candle(11 lux)measured at the center of treads and landings.There shall be a wall switch at each floor level to J
Q sMoKE DeTEGToR control the light source where the stairway has six or more risers. - MASTER N
no INTERGONHScTED Exception:A switch is not required where remote,central or automatic control of lighting is provided. �J BEDROOM 611
W/BATTERY BACK-UP. '� / _ _. .fl Ifl Z
PER IRG 514 fh US - ,.■
O CARBON MONOXIDE DETECTOR FOR ALL PERTY WALL5 LESS THAN 5'-0'TO THE T/ CZ p' «�•
PER IRG 515 PRO LINETeRiCR�SLL TOP OF WINDOWS Q
bA FILE NO.WP HION-PIKE TEST WP 8510 36 OPEN AT MAIN FLOOR d
O HEAT DETECTOR NL FILE O. -4H,UL D FIRE
TEST
V4 PIJY RAILING TO E9 AT HERY -
_ 'P 3x STUDS T UNLESS OTHERWISE O
m v L D'T°o ax+r�i ei H rL t PLATES NOTED(OR TRANSOM)
GARAGE NOTESr iHTri vTl `ws'A"HOTMro'mnrmTnFl-ATes. a 12'-b" In
_ U x AIR
HANDLER .n V
I. &ARAGE/LIVI NO SEPARATION,USE PIx FRIcrIaN T
5/H"TYPE X'bWB AT CEILING/WALL. Tuve� 'ACm ATH�Ha A' DUCTLESS �`\ 5x STUDS
WRAP PO5T5 AND BEAMS. ol¢roGloe.cee u.YeR ve•rTPe x Gv® MINI-SPLIT 4 PLATES
2.INSULATE ALL WARM WALLS AND _yIEWIrHTm urc LowTO SYSTEM —
GEILINb.
9. DOOR BETWEEN 6ARAGE AND RESIDENCE
SHALL BE 1-5/a, MINIMUM THICK SOLID WOOD LpYAa4e> x GYFeuM
OR STEEL WITH SOLID OR HONEYCOMB GORE ®ALV1eI�TOwo�oP It.G p F N ry
OR 20 MINUTE FIRE RATED EQUIPPED WITH A .rot 0
SELF CLOSIN'S DEVICE. �Cwo— TrnoraH M�Her rHlHu INTO DOE y
4. DUCTS IN GARAGE AND DUCTS PENETRATING THE 0F -y'D oo loo" -a
WALLS OR CEILINGS SEPERATINb THE RESIDENCE FROM m &BEAT l'6�
HAVE NO OPENINGS INTO THE&ARAaE N
ROOM KITCHEN 4 N 0
L
Q 'U ��ALL HEADERS, SINK
HEATING NOTE5, V' POST LOCATIONS,SEE I DW W DISP. data:
SHEET A-5 I I 6-fib-�I
i INSTALL PER p rJBY'IT11t:
SH R -H AE 9OA I
t H"PLATFORM V I /\ Ye VIB IOnS:
2 LAYERS 5/
5/4"PLYWOOD
II LAY
ON SLLAB)PLATFORM r,
SEE HEATINO NOTES
OPTIONAL NOTES. 7
RAISE ALL PILOTS,BURNERS
EL
AND SWITCHE5-IH"MINIMUM
ABOVE SLAB.
FIREPLACE NOTE DININ&
DIRECT RA rC, MREPLAGe w/ PAIR S.H. $Z�Qy( i ROOM drawn b LMD
FACTORY BUILT FIREPLACE SHALL In W U I INN, e-hoak0aI b MWJ
Be INSTALLED PER MANUFACTURER'S
SPEGIFICATION5 AND SHALL HAVE
APPROVAL LABEL ATTACHED
5/H°rrPE"x°bl^lS VERED q,�
TO ROOF SHEATHING PORCH Q()'
FACES 4 STOVES MUST BE 4
D.O.E.APPROVED 4 Be TESTED. P a N+n T
ice TIPIED 4 LABELED AS SUITABLE
FOR
IREPL USE DURING A FIR5T STAB. bt 36"OPEN RAILING -- --
BUR"N BAN. T
P2-4' h P2-4' T
* SHEAR NOTE. O '
SEE SHEET LI FOR SHEAR WALL 3x STUDS '�' 3x STUDS S
PLATES 4 PLATES
NAILING 5GHEDULE, 4 DETAILS.
PAIR SN.
HOLDDOWN 5GHEDULE
MARK HOLDOWN/ FASTENERS WOOD MEMBER ANCHOR W-6" 3'$" 2'-3' 2'-3' 6'-3" 6'-3"
STRAP THICKNE55/SPECIES REQUIRED
T-1 5THD14/14 RJ 24-I6d SINKER (2)2X4/2X6 5TUD5 6'-0'
HF/5PF
-0"
T-2 1-15748 (54)-16d (2) X4/2X6 STUDS
HF/S2PF MA I N rLOOK PLAN
T-5 M5TA56 (2b)-IOd (2)2X4/2X6 SUDS x «««««••«•«««+
HF/SPF 58e 61ENeRAL NOTES SGALI=. I/4"
T-4 MSTG48B3 (38)-IOd HF/SPF ««Plan Review
T-5 HDUB-SD52.5 (20)SD5 I/4° 4xb POST -I/8"ANCHOR By
BOLT
x a-v2„ City ofAr Ina on
VRIT2N DII-ffN510N5 ON T1115 DRAWING SHALL NAVE PRELEDENGE OVHi SLALFD DIMEN510N3.
LONTRAGTOR SNN.L VEiIFY ALL DIMENSIONS,CONDITIONS,ETL.PERTAINING TO Tiff WORK
BEFORE PROLffDINa.Tiff OVfIER MUST BE NOTIFIED OF ANY VARIATIONS FROM I ff
DIMENSIONS AIID/OR GOIR IMICR SHOWN ON THESE DRAWINGS.ANY^JKH VARIMION SHALL EE
RESOLVBJ BY THE OIMER PRIOR TO PROCEEDING WITH TIE WORK,OR THE CONTRACTOR SHALL
- AOOEFT FULL RESPONSIBILITY FOR THE COCi i0 RECTIFY SAIY.
�71 RE�IMTERED
12"24F-V46L_5_______
IQ'-O"LONG
�gt W a
' 4XIO V"2 L
III O 'w
v III C� F-i
O I
x
ALL EUILT UP STUD/COLUMNS USE a
Ibd NAILS•1211 O.G. 5TAGGERED , �g
TO ATTACH MEMBERS.NAILING 15 p I 5kVx12*24F-V4&LB
TO OCCUR AT THE FACE OF THE R FLUSH W/JOISTS
STUD C516 57RAP BOTH SIDES OF "r 25'O"LONG
BEAM TYPICAL AT BEAM TO
WALL/P05T CONNECTIONS
(2)2.12 +
B-2 f'
J
W
sm dc ad
Lu
Im
IIIIIIII -
1I I I I I I I
I I I I I I I
L R
NOTES. - - - -
ALL EXTERIOR WARM WALL5 TO BE 7 (2)ZXI2
2 X b STUD5 i 24'O.G.TYPICAL. -- - - - - - - -
INTERIOR WALL B S TO E 2 X I DS A - - - - -
X STU • L O.G.TYPICAL. - —_r— —
ALL HEADERS TO BE 4 X IO D1N2 I' L — — — 7
UNLESS NOTED OTHERWISE.
FUR-OUT HEADERS TO MATCH 2 X b t I O'
WALLS. O I
ALL EXTERIOR HEADERS MUST
INSULATED WITH R-10 INSULATION PER WE- a
FOR WINDOWS WITH OPERABLE OPENINGS MORE N
THAN-12"ABOVE THE FINISHED bRADE OR 51JRPACE . Y-
BELOW,THE LOWEST PART OF THE CLEAR OPEMN6, - - - - -
SHALL BE 24"MINIMUM ABOVE THE FLOOR.EXCEPTIONS, '
FULLY OPEN WINDOWS WHERE A 4"SPHERE MAY NOT _ _ J
PASS THROUGH OR WHERE FALL PROTECTION DEVICE5 I - -
ARE PROVIDED PER ASTM F 2090 OR R613.3
O I 2x@ FLR.JOUSTS
SOLID DLO-INS UNDER ALL BEARINb O 16"O.G_ - _ _
WALLS. LL C 4 Q
TUB/SHOWER UNITS SHALL HAVE FIRE
DLOGKI-BETWEEN WALL STUDS AND data:
WATERPROOF SURROUNDS TO.12" _ _
FROM DRAIN. &LAZING,INCLUDINb I p -28-�
WINDOWS WITHIN 112"OF DRAIN, 111]]] r ®rPY1It�
SHALL BE SAFTEY&LASS. SHONE?R
FLOW IS LIMITED TO 1.15&AL/MIN. _x L
EXHAUST FANS LARGER THAN SOCFM MAY SECONNECTED TO 4'SMOOTH WALL VENT FIFEIF RUNTS�MDO NO�TT EXCEED 20'II�N LagTH.DIAMETER WITH A MAXIMUM RUNTOF 15' - - I nab— - - -
-MBUSTION AIR REQUIRED FOR ALL - -
FUEL BURNING APPLIANCES
LEGEND. III 4xIO DFN2 I
BEARING WALL III
�_� BEARING ABOVE drawn byy LMD
�+ Ghacked�byl MWJ
_ FLOOR LINE ABOVE
Pr.Lv. POINT
I � 4XI0 DF42
ABV. TY POINT LOAD ABOVE
LTIPLE 3x STUD. T
o POINT LOAD
O SMOKE DETECTOR _ _ _ __ __
IOV INTPETE—EGTED
W/BATTERY BACK-UP.
PER IRC 514 �+q.��� PB-1 4XIO DM 4x10 DF112 A,ry ), O
O CARBON MONOXIDE DETECTOR
PER IRG 515
HOLDDOWN SGFIHDULE
MARK HOLDOWN/ FASTENERS WOOD MEMBER ANCHOR
STRAP THICKNES5/SPECIES REQUIRED
T-I STHD14/14 R-1 24-Ibd SINKERS (2)2X4/2X&STUDS
HP/SPF UPPER FLOOR
T-2 MST45 (54)-Ibd (2)2X4/2X&STUDS
HF/5PF
T-3 MSTA36 (26)-IOd (2)2X4/2X6 STUDS R G PL)4N
HF/5PF
T-4 MSTG4bB5 (5a)-IOd HF/SPF SEE GENERAL NOTES SCALE. I/4' Plan....+• R eN�eR,r
ANCHOR
x 2 Plan Review
T-5 HDUB-SD52.5 SDS 1/4.. 4xb POST-v2" BOLT By
City of Arlington
...........
WRITTEN 01-1-ON 115 ORAWINS SHALL HAVE PREGlDENOE OVER xALED DIMENSIONS.
GONT TOR SHALL VERIFY ALL DIH9610 ,,CONDITIONS,ETC,PERTMMIN TO THE WORK
BEFORE PROGEEDINS.TIE OVNER MUST M NOTIFIED OF ANY VARIATIONS PROM TFE
DIMENSIONS Alm/OR CONDITIONS S M ON TIEBE DRAWINGS.ANY SL'OM VARIATION SHALL M
�LVED BY THE OWNER PRICK TO PROCEEDING WITI THE WORK,OR TE LONTRACTOR SHALL
ACGER PLLL RE'..PONBIBILITY FOR t1E C T TO REGTFY SAME.
�TI
46
TOP OF
RE618TBREp
RGNITEGT
V I
- II
U a �
W
AT UPPER I PLDOM
OOR
JJJ C
TO E5 AT'IE 2020 PIG.
UNLE55 OTHERWISE
NOTED(OR TRANSOM) 2'-10"
g
AT 16 iV LINEN
IN5 pe O �
m chi W.H.FAN �I{
O ro K
BEDROOM
g N TWO p J
ry O ry�0 FAN O m W
iV 'e-5 I1ov SOD. S�D66FM �' w
BI-FOLD
O
50b8 O 3'-8" 2`10' Z
BI-PA55 1IOV s.v. W I]
Q -------
b In
N P<S 2668 F
LOFT
m U �� BEAMS ANDADERS, �
NOTES: Q h --- aQ SIET A jATIONS,SEE
ALL EXTERIOR WARM WALLS TO BE r LLU
2 X 6 STUDS o 24"O.G.TYPICAL. tl
ALL INTERIOR WALLS TO BE 2 X 4 STUDS o 24"O.G.TYPICAL.
ALL HEADERS TO BE 4 X 6 DF*2 �
UNLESS NOTED OTHERWISE. p It
FUR-OUT HEADERS TO MATCH 2 X b I -_P65--- 2666 2'-0" 6'
ALL EXTERIOR HEADERS MUST BE O
INSULATED WITH R-10 INSULATION PER WSEG 5068 IIOV8 O FAN Z
FOR WINDOWS WITH OPERABLE OPENIN65 MORE N V 5I-PA55 IIOV SD. Q/To N U V
THAN-12"ABOVE THE FINISHED GRADE OR SURFACE J
B LOW
EST TI
THE LOST PART OF THE CLEAR OPENING LL III 3'-b" `�O GFM Op: y
SHALL BE 24"MINIMUM ABOVE THE FLOOR.EXGEPONS, 6'-�" 2468
FULLY OPEN WINDOWS WHERE A 4"SPHERE MAY NOT ry
PA55 THROUGH OR WHERE FALL PROTECTION DEVICES O PG
ARE PROVIDED PER A5TM F 2OFO OR Rb12.5 fN
SOLID BLOCKING UNDER ALL BEARING .. ,
I
WALLS. BEDROOM BATHTUB/SHOWER UNITS SHALL HAVE FIRE .�pp FOUR Y in
BLOCKING EIETWEEN WALL STUDS.AND i
WATERPROOF SUMROUNOS TO♦12' Q In IN O
FROM DRAIN. &LAZING,INGLUDINO 77
WINDOWS WITHIN+12"OF DRAIN,
SHALL SE SAPTET&LASS. SHOWER O Q.
FLOW IS LIMITED TO 1.15&AL/MIN.
EXHAUST FANS LARGER THAN 50GPM MAY BE IIOV SD.
CONNECTED TO 4"SMOOTH WALL VENT PIPE
I H MINI..NOT
E—05.2.''UI�NT 5N65TH. LL a m pormlt:
DIAMETER WITH EA MAXIMUM RUN OP a B'
III rovla Iona:
FUEL B E PO STION AIR ME R ALL „I O
FUEL BURNING APPLIANCES -P15 IIII{ynyl
ry
LEGEND: Q I BEDROOM
BEARING WALL 7 THREE
IM_ BEARING ABOVE )
pp 4 N
FLOOR LINE ABOVE I Y m
PT.LIP. POINT LOAD ABOVE I I PAIR S.H. I t N
MULTIPLE 2.S� raven by LMD
o POINT LOADm Ghoakod by: MWJ
II —
O SMOKE DETECTOR III U
IIOV INTERGON W/BATTERY SAC—.
PER IRc 914 o I I 2020 PIG. N}-
O CARBON SM;NOXIDE DETECTOR a I
__PO_RG_H 2EL.OW_ ___
***SHEAR NOTE: ---- --- --- ry PI-4" r Ary PI-4' T
NA£IN6E 5G LI Po E, 4H AR 1,14 LLS.
PAIR S.H.
HOLDDOWN SCHEDULE
MARK HOLDOWN/ FASTENERS WOOD MEMBER ANCHOR
STRAP THIGKNESS/SPEGIES REQUIRED 4'-6' B'-6" 2'-6' 2'-0" b'
T-I 5TH014/14 RJ 24-Ibd SINKER (2)2X4/2X6 STUDS 8'-0" 4'-6" 12'-6"
HF/SPF
T-2 MST4b (34)-Ibd (2)2X4/2X6 STUDS 25'-0"
HF/SPF I I p e
T-3 MSTA36 (26)-IOd (2)2X4/2X6 STUDS U I- f R FLOOR PLAN
HF/SPF SEE 6E:NERAL NOTES SCALE: 1/4"
T-4 MSTG4855 (Bb)-IOd HF/SPF **** ** **+*+++++
T-5 HDUb-5D52.5 (2o)SD5 1/4" 4X6 POST "7/8"ANCHOR Plan+Review
X 2-I/2" BOLT BY
City ofArlington
WRITTBI DIMEN510N5 ON TIIS DRAWINS SHALL HAVE PRECEDBIGE OVER SCALED DIMEN510N5.
lDNTRAGTOR SHALL VERIFY ALL DIMENSIONS,COImITON5,ETO.PERTAINING TO TIE WORK
BEFORE PROCEEDING.TIIE OWER MUST EE NOTIFIED OF ANY VARIATIONS FROM TE
DII-ffN510N5 AIID/OR CONDITIONS To ON TffSE DRAWINGS.ANY SKH VARIATION
E 511ALL BE
RESOLVED BY TI OWNER PRIOR TO PROCEEDING WITH THE WORK,OR TIE CONRtACTOR SHALL
ACCEPT F4LL RESFONSIelurr FOR THE casr ro RecnFY SArx,
�rl PM�I9TGRlD
RCHIrecT
__ 315"xl2"24F-V4 GLB �
Iq'-0"LONG
6.12
aiI
a AFSO
❑ N ! 41
�'e� PRE.MFG.TRussEs
GABLE END .,
TRUSSES L 1 'F/-1 ^
BE DESIGNTOED
TO SPAN WINDOW/
DOOR OPENINGS
TYPICAL
D9 D9
❑ 2030 ❑
ATTIG 4'ExHWYT
A� AGGE55 ROOF Ago
N5 a W5 .IAZK❑
EAVE PROTECTION PER IRG R302.1 R�oNOF❑ ❑
IF EAVES ARE WITHIN 5'OF THE PROPERTY
LINE,THG IEN A ONE HOUR FIRE RESISTANCE J •_
RATINS REQUIRED IF THERE j RooF AllsT
ARE BIRD BLOCKING VENTS OR&ABLE END '�K❑ ,w H
VENTS.IF THERE IS SOLID BLOCKING AND Y N
NO VENTS,THEN THE FIRE RESISTANCE RATIN& LN
CAN BE REDUCED To ZERO HOURS. F24 x 'I .■ Clu
L A� =C
A- Z
ROOF VENT 1N ❑
LOCATIONS PER FLAN AP50 W
RINT i
VBTf
SOLID
BIRD
A HALL.. A Ago nFSo A m
OR LE5 FBROM �- ROOF ROOF
AFSO VBIT❑ ❑VEVT
THE PROP.LINE
TRU55E5 RBBF _...
PER PLAN
ry PRE.MF&.TRUSSES
LL e 24"O.G.
Cl I
I 1
Y
ex'�TERIOR
WALL a ❑ a m
ONE HOUR EAVE DETAIL(IF PLAN REQUIRES) N
CJ (V ■�nn1■
�&M❑ ❑vor, 4--ST z V
ROOF FRAMING NOTES ❑ ❑ j ' Z
�AP R TAILS TO NATGH 3x4 W
CONNECTORS SHALL BE ENGINEERED VBf�
BY TRUSS MANUFACTURER ju
,�^■,
ROOF PITCH SHALL BE 3,12 Nam.
TYPICAL UNLESS NOTED OTHERWISE
ROOF OVERHANG SHALL SE 12"U.N.O. AFSO AFGO 4•E%HN5T
2X&RAFTERS a 241 O.G. R�OaMF❑ El ❑
AT FIREPLACE BUMPOUT O
3xb oVERFRA.MING NO OVERHANG WITH NO
GUTTER AND NO ROOF VENTS SL
- BEA-BELOW
# ❑
p vs vowlNSPour
permit:
,� i ❑ Roo i reVlslons:
TRUSS NOTE vBtf Y
Y
ALL rRU99E9 SHALL HAVE.
VB/T
1. STRESS ANALYSIS AND DRAWIN69/
El
DETAILS STAMPED BY A STATE VENT
REGISTERED ENGINEER. ROOF ElROOF
VENT
3.MANUFACTURER'S STAMP ON PRE- Dg
MANUPAGTVRED TRUSSES.
9.BRACED TO MANUFACTURER'S
SPEGIFIGATIONS.
4.STRESS ANALYSIS AND DETAILS
SHALL BE SUBMITTED TO BUILDING I ❑ F drawn b LMD
DE PT.FOR APPROVAL AND SHALL III .BIT
BE KEPT ON SITE FOR FRAMINS a
ry �^Ibyl MWJ
INSPECTION. 3 III^ D9 1
GFIOGIG�
5. TRUSSES WILL NOT BE FIELD ALTERED 'Lk1111*II 3J12 �Q
WITHOUT PRIOR BUILDIN0,DEPARTMENT - O III ❑ Si--FEET
GALPGUOLATIONS,VAL OR ENGINEERINb Yx I Y
b.ALL TRUSSES SHALL HAVE SIMPSON 3,12 I1I
H-I CLIPS AT ENDS. WHERE TRUSSES Oa
ARE PARALLEL TO WALL,USE SIMF'90N
LSO AT MIDSPAN. USE 51MPSON STG — _PB-I -_--- --
GLIFS AT NON-BEARINS WALLS — — — — ——— DS
4x10 DF>•2 �F�
4
ROOF VENTING CALCULATION
14-72 50FT AREA =4.q0 SOFT REQUIRED HIP JAGC5
e 24"O.G.
300
(4.q0) X(5095)= 2.45 SOFT MIN. REQUIRED AT EAVE5
TYPICAL TRUSS BLOCK HAS(4) 2 4)SCREENED HOLES
PROVIDING 6.25 50. IN.(.044 SOFT) PER BLOCK.
APPROXIMATELY 0 VENTED BLOCKS= O SOFT PROVIDED
PROVIDE 10 AF50 VENTS AT SAVE LINE= 5.40 SOFT PROVIDED I\OQf= FRAM I NG PLAN
(4.qO) X(5096)= 2.45 SOFT MIN. REQUIRED WITHIN 5' OF THE RIDGE SEE GENERAL NOTES SCALE, 1/4" ***� **** ***t***
AF50 ROOF JACK VENTS= 54 SOFT EACH VENT
PROVIDE 10 AF50 VENT5- 5.40 SOFT PROVIDED By
TOTAL VENT AREA PROVIDED= 6.50 50 FT By
City of Arlington
�WRITTETI DIMENSIONS ON THIS DRAWING SHALL HAVE PRK.EDEIILE OVB2 scum DIMENSIONS.
CONIRAOTOF2 5HALL VERIFY ALL DIMENSIONS,LONDITONS,ETL.FERTAININS TO THE WORK
ACRE R20L®IH6.T£OVNER MNST BE NOTIFIED OF ANY VPRIATIONS FROM THE
,. DIMEN51015 A!ID/qi 001mITNJNS SHOWN ON TiESE DRAWINGS.ANY S:LH VARIATION SHALL BE
RE50LVID BY THE OWN3t PRIOR TO PROLEEDIN6 WITH THE YVORK,OR TFf LOMRALTOR SHALL
ALLEPi P.lLL RG�OIEIEILI`Y POR THE G:..T TC RELTiPY SF.-�.
■
�C
r^ .b
V J
2018 WASHINGTON STATE ENERC2Y CODE V U e
*'ALL CLIMATE ZONES (TABLE R402.I.I)
FENESTRATION 5K: 1—T GLAZED GEILINb WOOD FRAMED FRLOOR BELOW GRADE F.ND pREPvii1ALL£ O
U-FACTOR U-FACTORG TRATION R-VALVE WALL R-VALUE - LUE WALL R-VALUE rr^^ 1♦
10/IS R-10,2 FEET
V'
0.28 O�� NR R-49 R-21 R-38 R-21+TH � A
'"TABLE 406.5- ENERGY CREDITS (SINGLE FAMILY) U w
THIS,PLAN REQUIRE5 6 CREDITS SINGE IT 15 OVER 1500 5GIUARE FEET
AND UNDER 5000 SQUARE FEET
PRE.MF6.TRJ55E5
e 24"O.G.
OPTION GRED I T
HEATING
OPTION
2 HEAT PUMP (ELEGTRIG) I.0
Mum mmum
ENERGY PRESCRIPTIVE COMPLIANCE IS BASED .5 BEDROOM LOFT
OPTION ON TABLE R402.1.1 WITH THE FOLLOWING ,
MODIFICATIONS: TWO vi
1.3 VERTICAL FENESTRATION U=0.25 m
I W
FLOOR R-38
SLAB ON GRADE R-10 PERIMETER AND 5o FLR GLUED •� O
UNDER ENTIRE SLAB BELOW GRADE
R-10 PERIMETER AND UNDER ENTIRE t��
SLAB OR COMPLIANCE BASED ON _ _ PIN.PLR.UPPER = 7�
SECTION R402.1.4: REDUCE THE TOTAL FLR.J015T5 PER PLAN _ MAIN FL ooR P.L. W
CONDUCTIVE UA BY 596 - _ - iC
ENERGY COMPLIANCE BASED ON R402.4.1.:;!: •5
OPTION REDUCE THE TESTED AIR LEAKAGE TO
2,1 B.O AIR CHANGES PER HOUR MAXIMUM MASTER
BEDROOM
50 PASCALS AND
ALL WHOLE HOUSE VENTILATION REQUIREMENTS R-211N5.®
AS DETERMINED BY SECTION MI507.3 OF THE EMERIOR WALLS
INTERNATIONAL RESIDENTIAL CODE OR SECTION
405.5 OF THE INTERNATIONAL MECHANICAL CODE
SHALL BE MET WITH A HIGH EFFICIENCY FAN(S) ��••((�� y
(MAXIMUM 0.35 watts/cfm), NOT INTERLOCKED FIN.FLR MAIN ,n lJ-1 S
WITH THE FURNACE FAN (IF PRESENT). VENTILATION _ _
SYSTEMS USING A FURNACE INCLUDING AN ECM z y
MOTOR ARE ALLOWED, PROVIDED THAT THEY % L
■ ARE CONTROLLED TO OPERATE AT A LOW SPEED FLR.JoIST5 R-38 -
IN VENTILATION ONLY MODE -III III PER PLAN INWLAATTIRS II III � 6xX� i�•
ENERGY DUCTLESS SPLIT SYSTEM HEAT PUMP WITH NO 2.0 z Y V
OPTION ELECTRIC RE5I5TANGE HEATING IN THE PRIMARY
5 HEAT PUMP I A z
3.6 LIVING AREAS. A DUGTLES W TH
MINIMUM H5PF OF 10.0 SHALL BE INSTALLED AND
PROVIIDE HEATING TO THE LARGEST ZONE OF SGTION -?�
THE HOUSING UNIT
5EE GENERAL NOTE5 SCALE, I/4" 0 l
�l
ENERGY WATER HEATING SYSTEM SHALL INCLUDE
2.0 0 t
OPTION THE FOLLOWING: ELEGTRIG HEAT PUMP
• WATER HEATERG MEETING THE STANDARDS
Q
=•5 FOR TIER III OF NEEA'S ADVANCED WATER ■
HEATING SPECIFICATION dote: 6-28-2I
permit:
TOTAL revisions:
&.0 CREDITS
drawn by LMD
-hacked•by: MW.1
■ Si--FEE=T
O�
•
***Plan�Review
By
City ofAdington
HRIMN OIHENBIONB ON THIS WiA-YiIN6 9XPLL HAVE PRECEDENCE OVER 50ALED 01h 10N5.
(ANT240TOR SHALL VERIFY ALL DIMENSIONS,CONV ITIONS,ETC.PkRTAININS TO THE WORK
BEFORE PROOEEDINO.THE OY#ER MAT BE NOTIFIED OF ANY VARIATIONS FROM THE
' DIMBCMONB AND/OR LOHmIT10N5 SNOMN ON THESE VIW0 SS.ANY SUCH VARIATION BHALL%
RESOLVED BY THE OWIER RUCK To FRO(. 1"WITH THE WORK OR TE CONTRACTOR SHALL Ib MIN.
ACCEPT FULL R-S C GOUTY FOR TIE LOST TO RBCTIFY SME. PER
PLAN
2x TOP PLATE
NAIL SHEATHING A I,e�l
EXTENDER TO .. HEADER a 3"oz.
E.W. I\J ResISTEREo
RCH cc
END WALLS _..... 5FEARKALL PER PLAN v'I
•y i 3x OR(2)2x 3/4'MIN.T46 PLYWOOD S)B-FLOOR � N
I STUDS a ICY FIO ANAI NAILS W�
SHEAR NALL SCHEDULE 1 I; CONNECT PLYWOOD
PER 2015 150 :I vv ad NAILS a 3"O.G. FLOOR JOIST
I; TO ALL STUDS,PLATES PER PLANK ILA
KALL
GENERAL NOTES: BOLTS PER
HEADERS
SEE PLANS TO DETERMINE THE DIFFERENT DESIGNATORS FOR SHEAR WALL MATERIALS, •1 1• APA RATED SHT6.
NAILING,ANCHOR BOLTS AND 4OLDOWN5. LOCATE HOLDOHN5 AS CL05E AS P0551BLE TO THE END W MIN.24/0 EXP.I 1, P.T.SILL PLATE W/
OF THE' WALL. STHDI4 WOOD 1r5 II. %EAR WALL SCHEDULE W
ALL HOEDOWNS.A MI DBOLTS,WASHERS,d NAILS IN CONTACT WITH P.T.WOOD TO BE TO I CONCRETE35A'zl/4'SQ.W45FER5
HOT DIPPED GALVANIZE
06T-
PI ONE SIDE PLYWOOD OR EOUAL 'I -3x OR(2)2x N#4 LONE.TOP
•� P• PLATES;NAIL SHEiNTHING TO FINISHED GRADE P2 = TWD SIDES PLYWOOD :1L-�, EACH PLATE
VIb„ NAIL SPACING OP#STM.ANA BLK6. SILL OPTIONAL BASE HEM FIR#
MARK PLATE SIMPSON MASAP PLATE VALUE
PLYWD. ED6E5 FIaD PLATES =11 REOV. SOLT, ANGHOR5 NAILING (#/LF) m#4 HORIZ.s 12'O.G. •„
PI-6" ad b' 12" 6" 18"O.G. 2x4 5/6"s 4B" a 4a"d ENDS (2)Ibd•10" 240 (3)#4 VERTICALS 'm X 15"A.B.W/3"X5'X14" U m
PI-4" ad 4' 12" 4" 16"O.G. 2x4 5/8"a 32" ®30"d ENDS (2)Ibd a'I' 349 PLATE WA5HER 5f£DETAIL 2/61 z 6 qg
T'IMBEDMENT 7" FOR STEEL LAYOUT Z v rT, B tt433
PI-3`ww ad 3" 12' 3" 14"O.G. (2)Zx4/6 5/0'a 24" ®24"<ENDS (2)I6d a 5" 450 Y O W -
PI-2""" ad 2" 12" 2" 12'O.G. (2)2x4/6 3/4"a 24" a 15"#ENDS (2)I6d a 5• 555
P2-6•"* ad b" 12" 6" 10"O.O. (2)2x4/6 5/8"a 24" N/A (2)ISO a 5' 450 GONG STEM WALL '• •• ry
P2-4"ww 8d 4" 12" 4" 0°O.G. (2)2x4/6 3/4"a 20" N/A (3)I6d 6 5' -Too a
P2-3"** 8d 3" 12" 3" 8"O.L. (2)2x4/6 3/4"0 16" N/A N I6d C 5' 900 TOP OF SLAB
12" 2" 0"O.G. (2)2x4/6 3/4"• 12" WA (4)Ibd e 4• 11'10 UZ
GONT.FOOTING a, PER PLAN x
*-NOTE,WALLS WITH UNIT SHEAR OF 350#/ft.OR GREATER SHALL HAVE FRAMING
MEMBERS(STUDS d PLATES) ABUTTIN6 PANELS NOT LE55 THAN 3X MEMBERS OR(2)2X MEMBERS C
PER IBC 2015 AND 5DPW5-2015
PER SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC,CHAPTER -1 LATERAL RESTRAINT PANEL ^1 STriD HOLDOAN ® FOUNDATION
MEMBERS
(2)2X MEMBERS ARE OK IN LIEU OF 3X
STITCH NAIL DOUBLE STUDS AND PLATES TOGETHER WITH 1 SCALE I" I'-o" G SCALE: N.T.S.
lad NAILS a 12"O.G.STA&ERRED ON THE STUD FACE
I. USE PBVER-DRIVEN STEEL STUDS AND NAILS BY HILTY OR RAM5ET WHERE APPLICABLE.
2.PLYWOOD MAY BE INSTALLED EITHER HORIZONTALLY OR VERTICALLY.
3.50LID BLOCK WITH JOIST UNDER INTERIOR SHEAR WALLS.
5HEAR WALL NOTES
.+e.. 1/16'OSB OR PLYWOOD SHEATHING-USE ad COMMON OR GALVANIZED NAILS. BLOCK ALL PANEL DOUBLE 57W5 a HOLD" SIMP50N A-35 CLIP J
EDGES. LONG DIMENSIONS OF PLYWOOD MAY BE INSTALLED VERTICALLY.NAIL a 12"O.G.TO ALL 2x BLOCKING
INTERMEDIATE STUDS. WHERE 3"NAIL SPACING 15 SPECIFIED AT PANEL EDGES,USE 1-1/2"ad
SHORT NAILS OR 3X STUDS WITH ad COMMON NAILS. FOR 2"NAIL SPACING,USE 3X STUDS SFEARWALL PER PLAN TIE STRAP PER PLAN#L DROP TOP CHORD OF TRUSS
AND STAGGER PANELS. WHERE PLYWOOD 15 2 51DES OF WALL, JOINTS TO FALL ON ALL NAIL HOLES FILLED K/ TO ACCEPT 2X6 OUTLOOKER a5r
SEPARATE STUDS ON EACH SIDE. 3/4'MIN T#6 PLYWOOD SUB-FLOOR I6d COMMON NAILS lad NAIL EA.SIDE W
FLOOR PLYWOOD-USE ad COMMON NAILS a 10"O.G.AT INTERMEDIATE SUPPORTS,6"O.G. GLUED#NAILED-NAIL a 6'ED6E u.l
AT ALL PANEL EDGES AND 4"O.G.AT ALL SHEAR WALLS,UNLESS OTHERWISE SHOWN ON PLANS. #IT FIE D FU IOd NAILS �� O
FLOOR JOISTS-JOIST PARRALLEL TO FLOOR OPENINGS AND EXTERIOR WALLS SHALL BE OO.HP RIM FOR BOTTOM IE O
GROSS BLOCKED AT 4; EDGES W/(4)IOd NAILS FOR THE FIRST BAY. BIM PLAT:FORKAU NAIL c7
3"x 3" x I/4"SG7UARE WASHERS AT ALL ANCHOR BOLTS.PLATE WASHERS TO BE INSTALLED WITHIN PER SIEARTKALL SCHMV-5 _ .Z
I/2"OF SHEATHING
GABLE-END TRUSS PER PLAN W
T/16"OSB OR PLYWOOD 5HEATHIN6-STAPLE SCHEDULE p
ALLOWABLE SHEAR VALUES WITH HEM FIR#2 STUDS J
2"16 GA.STAPLES a l5 6A.STAPLES a 14 GA.STAPLES 6 A35 FRAMING ANCMOR MAY BE TRUSSES OR RAFTERS / m
B_IMIN AMI AT PI-6,AND PI-4 �/
y. 3"O.G.-2a0#/ft. 4"O.G.-280#/ft. 4"O.G.-505#/ft. TYPE SIEAR N4LL5,IF TE PER PLAN
2"O.G.-360#/ft. 2-1/2"O.G.-450#/ft. 3"O.G.-390#/ft. R.YHOOD PANS SPANS RIM
4"O.G.AND IOd NALL5 2"O.G.-504#/ft. JD15T AND IS NAILED TO BOTH
®6"O.G.-620#/ft. THE BOLTON RATE OF 51EAR
WALL ABONE AND THE TOP
FIELD SPAGIN6,12"O.G.NAIE5 E 5TAPLE5. PLATE OF THE HALL -ON
_ �__ _ lW THE EDGE NAILIN6 PATTERN
HBLDOWNS-INSTALL SIMPSON HOLDOWNS OR U5P HOLDOWN5 AT THE END OF SHEAR WALLS 5PEGIFIED IN SIEAR NALL TABLE SHEATHING#NAILING PER
WHEN SHOWN ON DRAWINGS. SHEAR WALL SCHEDULE
PER PLAN,SIMPSON 5THD14 OR USP STAD14 5IMP50N M5'T36 OR USP MST136 FLOOR '�
SIMP50N MST40 OR USP KST245 SIMPSON HDUB OR LISP TDXIO Oh'ANCHOR BOLT MIN. PER PLAN SIMP50N A35
SIMP50N MSTG4503 OR USP MSTG5453 24"EMBEDMENT,3"BOLT INTO(3)2x4(b)) �FRAMSFEAFHYLbTd ANGLE o 24"OA. (�
SGIEDULE M#
OVERHANG#FASCIA
DOUBLE 51UD5•HIOLDOFYI Vi z
%EARNALL PER PLAN 2x STUD HALL s Ib"O.G. Q
z ~
� z
STRAP HOLDOAN WALL TO WALL TYPICAL SHEARAALL TO ROOF CONNECTION Q—
`� SCALE. N.T.S. +�
L
Q
dote:
permit:
revlelons:
drawn by.
LMD
checkOd by. MWJ
SI-f�ET
ol=
LI
� I
"=Plan*Review
By
City ofArlington —
YRITTEN DIMENSION5 ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.
BEFORE PROCEEDING.THEI Ow,BR M BE NOTIF TIOF ANY VARIATI IONS FROM THE
DIMEN510N5 AND/OR CONDITIONS 5HOW1 ON THESE DRAWINGS.ANY 5KH VARIATION SNALL BE
RESOLVED BY THE OwER mR oR To F'ROCEED1.WITH THE WORK,OZ TIIE rgNTRAGTOR SHALL
ACCEM FULL RE5 51BILITY FOR T11E CO'T TO RECTIFY SAVE.
ftG6I9 L GC
1 A CMITtGT
11
WASH AND ASSOCIATES
GENERAL NOTES: . �,,�{
03�4 I.All construction pper appplicable codes and ordinances.
ROOFING MATERIAL 2018 IRC,IBC.-2018 WASHIN6TON STATE ENERGY CODE
FIN15H PER ELEVATION
ON T/16"OB5 SOLID CDX 24-0 PLYWOOD 2.Verify all dimensions on job site.Bring discrepancies
SHEATHING;8d a 6"O.G.EDGE
Designer.
to the attention of Owner and/or Desl
8d o 12'O.G.FIELD 9
OSB AGX PLYWD o EVES)24"CARDBOARD BAFFLE MIN 5K UNDERLAYME °aX 3�4„ 3.Owner will verify window sizes and monufacturer(s)with
.1
ALLOW FOR I'AIR SPACE NAIL b"EDGE,12"FIELD Q framer before start of construction.
HANDRAIL: 4.One window per bedroom shall meet egress code.
WITH 8d NAILS,U.N.O. GRIP Ikl"-2"A t•
IN.EXTEND 12'ABOVE PROJECTION FROM
INSULATION. p �
WALL NO LE55 N051N6 5.Skylight glazing per 2015 IBG.
THAN Ilk,". rT,
Z 6.Truss manufacturer shall supply shop drawings to Owner
1 and framer to review and approve before Fabrication.
50LID SHEATHING
OR GDX PLYWD. (V I I I �.Owner will verify electrlcal and heat layouts with l °`
WHERE EXPOSED — I Installer before Installation. U < 2
TO HEATHER OPEN
I I I I 8.Under all parallel bearing walls,use double joists or as
OPEN 5P IA L.
BETWEEN I I I 1 noted on plan. Double joist(or extra TJU under ail non- P '
I I I bearing parallel walls. O 3
TOP PL. PICKETS SHALL BE I I
7—
LESS THAN 4"CLEAR I I I I I cf.TJI products to be Installed per manufacturer's con
IW/METALA BD. I I I I I I 1✓ HANGER Installation guide and approved reports. M
cuTTER APPROVED TRUSSES BEARING I 1 I y 10.A11 metal connections to treated Wood 5ha11 be at a W �I
MANUFAGTURER5 SEAL. f i1 I I 11 1 1/ /
SEE ROOF FRAMING PLAN 1 1 j' minimum;triple zinc ZMAX(GI85 per ASTM A653);Hot Dip
FOR SPACING m 1 J / Golvanze(A5TM AI23 for connectors and A5TMI53 for
11 yI/ fasteners and anchors. W
INSULATE PER WSEG
y II.All bathroom fans,kitchen hood,and dryer ducts shall be
2X BIRD BLK'6.W/ )':X 10'ANCHOR BOLT Y41 3"X3"X exhausted through the attic to the roof or through the
2'5CREENED VENT /�'PLATE WA5HER5 0 48"o.c.NO / j floor system to an outside wall. All wall ducts shall Z
HOLES WITH I/4" LE55 THAN 4Y 6 NO MORE THAN 12" 2X4 STOP 3-2x12 terminate at least 36"from a window opening. 8
CORRP51ION RE515TANT LIVING AREA FROM EA.END SILL CORNER,JOINT, STRINGERS
METAL MESH COVERING
END,OPENING ETC. T"MIN.
FIRE BLOCK ALL VERTICAL EMBEDMENT INTO GONG.EXCEPT O 2-2X HEADER IQ
OPENINGS IN WALLS AT SHEAR WALLS-SEE SHEAR WALL �
PLATES AND FLOORS NAILING SCHEDULE.
FLOOR JOISr 2x4 BLoucING I CLIMATIC AND GEOGRAPHIC
2.P.T.SILL I (FIRESTOP) DE516N CRITERIA:
I -
_ TERMITE. SLIGHT TO MODERATE f'
xX f 1° •4 REBAR o 16"O.G.HORIZONTAL FIREBLOCK5 xO DECAY: SL16HT TO MODERATE v
FLOOR JOISTS,5IZE AND S FIREBLOGK STAIRS: \ WINTER DESIGN TEMP: 26. j
Y ONCE IN TOP a BOTTOM
SPACING PER PLAN ° OF RUN BETWEEN 5TRIN6ER5 IGE5HIELD REQUIRED, YES yj
FIN. FLR. \ Q "' b ALONG RUN BETWEEN STUDS \ FLOOD HAZARDS. 2o03 Igg2 FIRM LU
— — •4 REBAR a 48"0.75,a(ERTIGAL W
�..
USABLE SPACE UNDER STAIRS AIR FREEZING INDEX: 250 W
TO BE 1 MR FIRE CONSTRUGTION \ MEAN ANNUAL TEMP: 46 80� e1
° 3"MIN. 5/8"TYPE'X'G.WB,(TWO LAYERS
TOP PL. L.
TYP. AT STAIR CEILING) \ o Z
— — \ DE516N DATA: i
.4 REBAR
W"J"BAR CWC
(2)2x TOP PLATE,LAP CORNERS, ROOF LOAD5: LL 25./SF(5NOW) i
OFFSET END JOINTS BY 48" DL I5./5F / m
ALL FOOTINGS TO BEAR ON TOTAL 40u/SF v
EIEARIN6 SOIL STAIR OT 5:
v"GYP5UMWALLBOARO,TYP, eSTAIR PETAL - TYFICAL R15ER HEIGHT = 7-5/4" MAX. FLOOR LOADS: LL 40./5F
TIC.O55.OR PLYWD.SHEATHING. W/f'VA VAPOR BARRIER e WALLS TREAD DEPTH = 10" MIN.
NAIL6"EDGE,12"FIELD WITH 8d AND GEILIN65 �71 SCALE,N.T.5. TOTAL
I 50K/SF
NAL5 UNLE55 NOTED OTHERH15E ST17. FOUNflAT 1 ON r.'ETA I L DECK LOADS: LL 60M/5F
2
GI SCALE.N.TS. TOTAL 0 5F
2x SNDS s 16"Q.G.TYP. LIVING AREA y
5aL: 1500 PSF MINIMUM in
FIRE BLOCK ALL VERTICAL GGNCRETE, 2500 P51 AFTER 25 DAYS
OPENIN65 IN WALLS AT (5vs SACK MIS �11
PLATES AND FLOORS
P FOR EXTERIOR FOUNDATION
HALLS N O
WALLS,PORCHES,STEPS,AND OR
GARAGE SLABS-AIR ENTRAINMENT
IS BETWEEN 5-996(TABLE 4022 IRC)
k"X 10"ANCHOR BOLT W/3'X3'X}" v
SIDING,SEE PLAN FOR TYPE PLATE WA5HERS a 48"of NO LE55 Z
THAN 4j"6 NO MORE THAN 12' STEEL
MASONRY: PER 2018 IBC
FROM EA.END SILL CORNER JOINT, STEEL: PER 2018 IBC(GRADE 40)
END,OPENIN6 ETC. T"MIN.
EMBEDMENT INTO GONG.EXCEPT e GARAGE WOOD: PER 201 IBC Q
SHEAR WALLS-SEE SHEAR WALL NAILING: PER 2018 IRC NAILING PER TABLE
R6023(I),R802.10
NAILING SCHEDULE. WIND, 85 MPH V
TOP FLANGE J015T 585mir, ZONE-DI
HANGER PER PLAN V=see design calwiatlore(ml) Q
2.BOTTOM PLATE W Tt(GL6 N41PLYWOOD SUB-FLOOR
UED< LED)NAIL 6'EDGE, INSULATE PER WSEG., THERING POTENTIAL:MODERATE SL
2x P.T.SILL 61 FIELD W IOd NAILS. 50LID BLOGKIN6 a FRO5T LINE, 1212N "
BRG.WALL ABOVE TYP.
E.F.P.. 45 PSF
FIN.FLR. _ — — a"BEAM. DWGLAS FIR R2
data: b-�B-�I
4"GONG.SLAB BED
er'm it:
-- - -- 4"GRANULAR BED 6"BEAM: ffb_ 15 P51 reVlelone:
D A D.S.TI5TORME,POSITIVE
DRAIN TO STORM SYSTEM _ r d "I
011 dj 4"POST. DOUSLA5 IFIR#2
FIN.GRADE TO SLOPE -_-.....--_.— _..-- Alool000
° ° a
AWAY FROM BUILDING �. A 6'POST, Fv= 1
E =.30 1po
FLOOR J015T5,SIZE AND
\� \ 45" MAX. SPACING PER PLAN J0155 RAFTERfv S HEM FIR 1
GRAWLSPAGE fb=eso Psi
iV \/�\ UNBALANCED GLu-LaH��
E=I,500,D00
n (TALLER WALLS PER PLAN 5EE FOUNDATION PLAN dr•gWY1 b LMD
FOR BEAM 5IZE 6
POST 5IZE/SPACING 2x4 GUSSET EA.SIDE y
fv=2,4 psi checked�b , MWJ
REBAR PLACEMENT fb=2,400 psi(reduced N size y
— \ SEE DETAIL•2 ABOVE q0+FELT '51MPSON'H6AM10 Factor,GF•KU
_ POST TO GONG. E=I,BOO,QOO psi SI—IEET
NOTE:
J ° VARIATIONS FROM THE ABOVE
6 MIL.POLY VAPOR BARRIER n ° d
LIMBER N THE PLANS.RADES WI BE
\ ALL REINFORCEMENT _
. V MIST BE TIED IN PLACE I SUBFLOOR.
4"A FERF FOOTING DRAIN TILE O�
4"CLOTH COVER t GRANULAR FOR FOUNDATION INSPEGITON TFG PLYWOOD OR O5B APA RATED
STLRD-I-FLOOR 16.O.G.,3/4"
COVER AS REQb.BY SOIL SEE FOUNDATION PLAN SEE FOUNDATION PLAN WALL ROOF SHEATHING:
CONDITIONS FOR FTC./FDN.511E FOR PAD 5IZE APA RATED 5HEATNG 24/I6 7/I6"
ALL FOOTINff TO BEAR ON ALL FOOTING5 TO BEAR ON
FOOTING FOR
BEARING SOIL BEARING 50IL 6'WALL-18'x 12'FOOTING
24'BELOW GRADE
04 5TU13 STEEL-48'oc.VERY.
UNLESS NOTED OTHERWISE
TYPICAL WALL SECTIONS
GI SCALE,N.T.S. **
.. .....................
Plan Review
By
City ofAdington
.............
.H.......
..R