HomeMy WebLinkAbout16410 Smokey Point Blvd_BLD1412_2026 CITY OF ARLINGTON } 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 _- PHONE; (360)403-3551 BUILDING PERMIT Address:16410 Smokey Point Blvd, Permit#:1412 Parcel#:31052900100800 Valuation:60000.00 OWNER APPLICANT CONTRACTOR Name:SMOKEY POINT PROFESSIONAL Name:Evergreen State Heat&AC Name:EVERGREEN STATE HEAT&A/C GROUP LLP Address: 1505 E 5TH ST Address:2120 Pacific Avenue Address:2120 Pacific Ave City,State Zip:ARLINGTON,WA 98223-1125 City,State Zip:Everett City,State Zip:Everett,WA 98201 Phone: Phone:425-252-3114 Phone:425-252-3114 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:EVERGREEN STATE HEAT&A/C Name: Address:2120 Pacific Ave Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-252-3114 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Mechanical CODE YEAR: 2015 STORIES: 3 CONST.TYPE: DWELLING UNITS: 0 OCC GROUP: BUILDINGS: I OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI10/IRC110. SALES TAX NOTICE:Sales tax relating to construction and -traction materials in the City of ArIinjt9Mnws1 be repo ed on your sales tax return form an co d C' of Arlington#3101. L/ -747 Sigr4u& Print Name Date Itelcased By Date CONDITIONS Approved as submitted. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 4/7/2017 Mechanical Plan Review Fee $657.59 Total Due: $657.59 Total Payment: $657.59 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon i CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:16410 Smokey Point Blvd, Permit#:1412 Parcel#:31052900100800 Valuation:60000.00 OWNER APPLICANT CONTRACTOR Name:SMOKEY POINT PROFESSIONAL Name:Evergreen State Heat&AC Name:EVERGREEN STATE HEAT&A/C GROUP LLP Address: 1505 E 5TH ST Address:2120 Pacific Avenue Address:2120 Pacific Ave City,State Zip:ARLINGTON,WA 98223-1125 City,State Zip:Everett City,State Zip:Everett,WA 98201 Phone: Phone:425-252-3114 Phone:425-252-3114 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:EVERGREEN STATE HEAT&A/C Name: Address:2120 Pacific Ave Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-252-3114 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Mechanical CODE YEAR: 2015 STORIES: 3 CONST.TYPE: DWELLING UNITS: 0 OCC GROUP: BUILDINGS: I OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1 IOARC110. SALES TAX NOTICE:Sales tax relating to construction and nstruct ion materials in the City ofAriin to st be repo ed on your sales tax return form an co C' of Arlington#3101. y-7-l7 Sig Print Name Date keleased By Date CONDITIONS Approved as submitted. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 4/7/2017 Mechanical Plan Review Fee $657.59 Total Due: $657.59 Total Payment: $657.59 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon ti r InformationPermit Date 4/4/2017 Permit Number 1412 Project Name Smokey Point Professional Group Applicant Name Evergreen State Heat&AC Applicant Address 2120 Pacific Avenue City, State, Zip Everett Contact Mark Payne Phone 425-252-3114 Email russ@essmwa.com Permit Type Commercial Mechanical Site Address 16410 Smokey Point Blvd, Valuation 60000.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 0 Proposed Use Replace NE corner 15 ton RTU Assigned To Launa Peterson Properly • • Owner Parcel#:31052900100800 SMOKEY POINT PROFESSIONAL GROUP LLP SMOKEY POINT PROFESSIONAL GROUP LLP 1505 E 5TH ST 16410 SMOKEY POINT BLVD ARLINGTON,WA98223-1125 Contractors Contractor Name Primary Contact ERGREEN STATE HEAT&A/C IMark Payne 25-252-3114 1 1CONTRACTOR bor&Industries EMRGSS0220T71 Review Date Type Description Target Date Completed Date Ass4gned To Status 14/2017 rommercial Mechanical /18l2017 I Fick Karns In Review Fees Fee Description N. Amount Mechanical Plan Review FeW 322.10.00.001 1 $657.59 Payments Date Paid B� Amount Description Payment .- Accepted 4/4/2017 Russell Kimbell 857.5 142116 Total )7 59 Amount • . 0 00 Uploaded FileUpload File By 4/4/2017 2:26:42 PM I Mech Specs.xism Peterson,Launa X 4/4/2017 2:26:42 PM IMechanigil Permit Application Cl f2xrdflWMJwv.uii IPeterson, Launa k V x COMMERCIAL MECHANICAL • PERMIT APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF CONSTRUCTION DRAWINGS AND ALL OTHER INFORMATION OUTLINED IN THE MECHANICAL PERMIT SUBMITTAL REQUIREMENTS, IF APPLICABLE. Type of Permit: ❑ New Installation 0 Replacement ❑ Alteration Project Address: 16410 Smoky Point Blvd Parcel#: 31052900100800 eplacement of NE corner 15 ton RW 60,000 Project Description: -__ -Valuation: Owner:Smoky Point Professional group Phone#:425-239-5074 Address: 1505 E. 5th St City:Arlington State:WA Zip:98223 Email Address: dale@me.com dale Duskin --- - — Contact Person: Phone#: 425-239-5074 Address: 1505 5th St City:Arlington State: WA Zip: 98223 Email Address:DALE@ME.COM Contractor Name:Evergreen State Heat & AC Phone#: 425-252-3114 Contractor Address:2120 Pacific Ave City:Everett WA 98201 - State: Zip: Email:mark@essmvira.com Contact Person:mark Payne Contractor License Number: EVERGSS0220T Expiration: Nov- 17 Please indicate type of number of appliances: FURNACE CONDENSING UNIT GAS PIPING OUTLET BOILER HEAT PUMP(multi-split) UNIT HEATER CHILLER HEAT PUMP(mini-split) PAINT BOOTH COOLER HEAT PUMP(other) TYPE I HOOD AC(air cooled) HEAT REJECTION EQUIP TYPE II HOOD AC(water cooled) VENTILATION SYSTEM AST AC(evaporator) PACKAGED UNIT UST AC(VRF) DRYER OTHER I hereby certify that the above information is correct and that the construction.on, and the occupancy and the use of the above- described property will by in act laws rules and regulation of the State of Washington_ Applicants Signature: Date 04/04/2017 Applicants Printed Name: Mark Payne Received I ^ FOR STAFF USE ONLY .APR Q 4. 2m Permit# ' A pled Amount Received Receipt# Date Received 6/16LP Page 1 of 1 2601 Everett Ave, Everett, WA 98201 - Bing Maps Page 1 of 1 � 1 J>bing maps 16410 Smokey Point Blvd, Arlington,WA 98223 Replacing ne corner unit with like for like.Same capacity,size, location and weight. SM ' � -Jam►. - �-► . w .ram t - I r 2�pled,1 PJ U� �T Received https://www.bing.com/maps?&ty=18&q=2601%2OEverett%2OAve%2c%2OEverett%2c%20... 4/4/2017 1 +l i ��: I I 2015 Washington State )orgy Code Compliance Forms for Commercial, R2' ')R3 over 3 stories and all R1 Mechanical Summary MECH-SUM 2015 Washington State Energy Code Com fiance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 Project Information Project Title: Cumulus Park NE Date 4/3/2017 Applicant Information. Provide contact information for individual who can respond to For Building Dept.Use inquiries about compliance form information provided. Company Name: Evergreen State Heat&A/C Company Address: 2120 Pacific Ave,Everett,WA 98201 Applicant Name: Mark Payne Applicant Phone: 425-252-3114 Project Description ❑ New Building ❑ Building Addition ❑ Tenant Improvement Q System Retrofit ❑ No System Changes Briefly describe mechanical systems in Replacing like for like with same capacity,power requirements and gas heat as old unit..old unit provided the text box provided sufficent heating and cooling.Unit is a single phase 5 ton RTU. ❑ Total Bldg Performance(TBP) This path includes all mandatory ^ provisions per C401.2 Option 2. MECH-SUM,MECH-CHK,and C407 1 Energy Analysis forms required, ❑ Load calculation summary M H-LOAD-CALC Form Design Load Calculations Provide design load calculations for all mechanic I systems and equipment serving the building heating,cooling or ventilating needs.If a load calculation summary is p Iwded with the permit documents that includes all applicable compliance information then the MECH-LOAD-CAL- r is not required. ❑✓ Mechanical Plans ❑ MECH-EQ Form 8D) Mechanical Schedules Indicate location of equipment compliance information If provided on plans then MECH-EQ forms are not required, however,include on plans all applicable compliance information listed in MECH-EQ tables. ❑ DOAS is required per C403.6 effective July 1,2017(office,retail,education,library and fire station occupancies) All occupied,conditioned areas shall be served by a DOAS that delivers requi ventilation air in a manner that does not require space conditioning fan operation. Space conditioning fans cycled off n no heating or cooling is required. Dedicated Outdoor Air ❑ Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS(C403.6,Exception 1) System Requirements and ❑ ventilation and space conditioning provided by a HEVAV system per C403.7 in lieu of DOAS(C403.6,Exception High Efficiency VAV ❑ DOAS included in project,although not required(occupancy not office,retail,education,library or fire station) Alternate ❑ DOAS related allowances included in project: ❑ Prescriptive vertical fenestration maximum area allowance increased to 40%per C402.4.1.4 with 100%of conditioned floor area in building served by DOAS. ❑ Exception to air economizer per C403.3 Exception 1,include MECH-ECONO form. Q Project includes HVAC air distribution systems that provide heating and/or cooling If yes,provide a MECH-FANSYS-SUM form. Fan Power ❑ For one or more systems,the total fan motor nameplate hp of all fans in HVAC system exceeds Shp. If yes,provide a seperate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold. Refer to Section C403.2.11 and MECH-FANSYS-DOC for requirements and exceptions. ❑HVAC Hydronic Systems Hydronic chilled water ❑ Water-loop heat pump ❑ No hydronic systems ❑ Hydronic heating water ❑ Geothermal ❑ C406.2 More efficient HVAC equipment and fan systems Requires 90%of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9)or air-to-water heat pumps and heat recovery chillers.All equipment listed in tables C403.2.3(1)-(7)must be 15%more efficient than minimum requirements.All stand alone supply,retum,and exhaust fans over 1 hp must have FEQ z 71 and must be C406 Additional Efficiency selected within 10%of maximum total or static pressure. ❑ C406.6 Dedicated outdoor air system(DOAS) Options-Mechanical Requires 90%of conditioned floor area to be served by a DOAS per C403.6 that delivers required ventilation air in a manner that does not require space conditioning fan operation. ❑ C406.7 Reduced energy in service water heating Received Requires 90%of floor area be in occupancy types listed in C406.7.I and that 60%of annual hot water energy use be provided by heat pump,waste heat recovery or solar water-heating systems. APR 0 �� k I I 1 2015 Washington State--Trgy Code Compliance Forms for Commercial, R2 --A R3 over 3 stories and all R1 , Mechanical Summary MECH-SUM 2015 Washington State Energy Code Corr Dliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 Project Information Project Title: Cumulus Park NE Date 4/3/2017 Applicant Information. Provide contact information for individual who can respond to For Building Dept.Use inquiries about compliance form information provided. Company Name: Evergreen State Heat&A/C Company Address: 2120 Pacific Ave,Everett,WA 98201 Applicant Name: Mark Payne Applicant Phone: 425-252-3114 Project Description ❑New Building El Building Addition ❑Tenant Improvement ElSystem Retrofit El No System Changes Briefly describe mechanical systems in Replacing like for like with same capacity,power requirements and gas heat as old unit..old unit provided the text box provided sufficent heating and cooling.Unit is a 3 phase 15 ton RTU. ❑Total Bldg Performance(TBP) This path includes all mandatory provisions per C401 2 Option 2 MECH-SUM,MECH-CHK,and C407 Energy Analysis forms required ❑ Load calculation summary El MECH-LOAD-CALC Form Design Load Calculations Provide design load calculations for all mechanical systems and equipment serving the building heating,cooling or ventilating needs If a load calculation summary is provided with the permit documents that includes all applicable compliance information then the MECH-LOAD-CALC form is not required El Mechanical Plans ❑ MECH-EQ Forms(TBD) Mechanical Schedules Indicate location of equipment compliance information.If provided on plans then MECH-EQ forms are not required, however,include on plans all applicable compliance information listed in MECH-EQ tables. ❑ DOAS is required per C403.6 effective July 1,2017(office,retail,education,library and fire station occupancies) All occupied,conditioned areas shall be served by a DOAS that delivers required ventilation air in a manner that does not require space conditioning fan operation.Space conditioning fans cycled off when no heating or cooling is required. Dedicated Outdoor Air ❑ Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS(C403.6,Exception 1) System Requirements and ❑ Ventilation and space conditioning provided by a HEVAV system per C403.7 in lieu of DOAS(C403.6,Exception High Efficiency VAV ❑ DOAS included in project,although not required(occupancy not office,retail,education,library or fire station) Alternate ❑ DOAS related allowances included in project: ❑ Prescriptive vertical fenestration maximum area allowance increased to 40%per C402.4.1.4 with 100%of conditioned floor area in building served by DOAS. ❑ Exception to air economizer per C403-3 Exception 1,include MECH-ECONO form. [2] Project includes HVAC air distribution systems that provide heating and/or cooling If yes,provide a MECH-FANSYS-SUM form. Fan Power ❑ For one or more systems,the total fan motor nameplate hp of all fans in HVAC system exceeds 5hp. If yes,provide a separate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold. Refer to Section C403 2 11 and MECH-FANSYS-DOC for requirements and exceptions. HVAC Hydronic Systems ❑ Hydronic chilled water ❑ Water-loop heat pump ❑ No hydronic systems ❑ Hydronic heating water ❑ Geothermal ❑ C406.2 More efficient HVAC equipment and fan systems Requires 90%of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9)or air-to-water heat pumps and heat recovery chillers.All equipment listed in tables C403.2.3(1)-(7)must be 15%more efficient than minimum requirements.All stand alone supply,return,and exhaust fans over 1hp must have FEQ>_71 and must be C406 Additional Efficiency selected within 10%of maximum total or static pressure. ❑ C406 6 Dedicated outdoor air system(DOAS) Options-Mechanical Requires 90%of conditioned floor area to be served by a DOAS per C403 6 that delivers required ventilation air in a manner that does not require space conditioning fan operation. ❑ C406 7 Reduced energy in service water heating Requires 90%of floor area be in occupancy types listed in C406.7 1 and that 60%of annual hot water energy use be provided by heat pump,waste heat recovery or solar water-heating systems. 2015 Washington ""Nte Energy Code Compliance Forms for Commerce' -12 and R3 over 3 stories and all R1 Mechanical Summary, ra 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 Equipment Type(s) ❑ Hot water heating tank(s) ❑ Instantaneous ❑ No service water systems Service Water Heating ❑ Dedicated boiler ❑ Heat exchange from space heat boiler or Systems central hot water/steam Distribution Type(s) n Circulation System ❑ On-demand Commissioning Commissioning is required for: ❑ Mechanical systems per C408.2 ❑ Service water heating systems per C408.4 If required,commissioning shall be performed for all applicable systems regardless of individual equipment capacity. Exceptions to commissioning requirements: F,� Total output capacity of all mechanical space conditioning systems in the building do not exceed 240,000 Btu/h cooling or 300.000 Btu/h heating.Mechanical systems commissioning not required. ❑ Capacity of largest service water heating system in building does not exceed 200,000 Btu/h Service water heating systems commissioning not required. Low Energy and Semi-Heated Spaces (Note 6 and 7) Pea K space Heating Cooling Conditioning Space Area Served, Capacity,Btu/h Capacity,Btu/h Capacity, Compliance Type Location in Plan(s) Space(s)Served square feet (Note 4) (Note 5) Btu/h-sf Check Notes Note 4-Provide total installed heating output capacity of systems serving Low Energy or Semi-Heated space(s)in btuh. Note 5-Provide total installed cooling capacity of system serving Low Energy space(s)in Btu/h.Not allowed for semi-heated spaces Enter 0 if no cooling. Note 6-Refer to Section C402 1.1 Low Energy Building.Intalled peak space conditioning capacity,heating or cooling,may not exceed 3.4 Btu/h"sf. Note 7-Refer to Section C402.f 1 1 and Semi-Heated Space definition in Chapter 2 Total heating output capacity may not exceed 8 Stu/h"sf. Only systems without electric resistance heating and no cooling are eligible for the wall insulation exception under semi-heated 2015 Washington Statt~F `'prgy Code Compliance Forms for Commercial, R2 �)R3 over 3 stories and all R1 , Mechanical Summary, • • 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 Equipment Type(s) ❑ Hot water heating tank(s) ❑ Instantaneous ❑ No service water systems Service Water Heating Heat exchange from space heat boiler or Systems ❑ Dedicated boiler ❑ central hot water/steam Distribution Type(s) ❑ Circulation System ❑ On-demand Commissioning Commissioning is required for: ❑ Mechanical systems per C408.2 ❑Service water heating systems per C408.4 If required,commissioning shall be performed for all applicable systems regardless of individual equipment capacity Exceptions to commissioning requirements: ❑ Total output capacity of all mechanical space conditioning systems in the building do not exceed 240,000 Btu/h cooling or 300.000 Btu/h heating.Mechanical systems commissioning not required. ❑ Capacity of largest service water heating system in building does not exceed 200,000 Btu/h.Service water heating systems commissioning not required. Low Energy and Semi-Heated Spaces (Note 6 and 7) Peak Space Heating Cooling Conditioning Space Area Served, Capacity,Btu/h Capacity,Btu/h Capacity, Compliance Type Location in Plan(s) Space(s)Served square feet (Note 4) (Note 5) Btu/h-sf Check Notes Note 4-Provide total installed heating output capacity of systems serving Low Energy or Semi-Heated space(s)in btuh. Note 5-Provide total installed cooling capacity of system serving Low Energy space(s)in Btu/h.Not allowed for semi-heated spaces.Enter 0 if no cooling. Note 6-Refer to Section C402.1.1 Low Energy Building.Intalled peak space conditioning capacity,heating or cooling,may not exceed 3.4 Btu/h'sf. Note 7-Refer to Section C402.1.1.1 and Semi-Heated Space definition in Chapter 2. Total heating output capacity may not exceed 8 Btu/h"sf. Only systems without electric resistance heating and no cooling are eligible for the wall insulation exception under semi-heated. `_j, �� . � r 2015 Washington State Energy Curie Compliance Forms for Commercial,R2 and R3 over 3 stories and all R1 -Page 1 of 7 PermitMechanical Plans 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 Project Title: Cumulus Park NE Date 4/3/2017 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code,Commercial Provisions. Applicable Code Section Code Provision Information Required-Must be in permit documents Location in Building Department es,no,na) Documents Notes Equipment-Sizing,Performance and Type Identify equipment to be used in manufacturing,industrial or commercial processes that do not C403.1 Exempt process equipment provide space conditioning;identify provisions applicable to this equipment per C403.1 exception Provide load calculations performed per ASHRAE Std 183 or equivalent,using design IReplaceme C403.2.1 Load calculations parameters per C302 and Appendix C;include load adjustments to account for energy int recovery Equipment and system Indicate that output capacities of heating and cooling equipment and systems are no greater iReplaceme C403.2.2 than the smallest available equipment size that exceeds the calculated loads;note exceptions nt sizing taken Per cut C403.2,3 HVAC equipment Provide equipment schedules on plans or complete MECH-EQ forms indicating type,capacity, sheets Tier Yes C403.2.3.2 performance requirements rated and WSEC minimum efficiencies for all heating and cooling equipment;include supply 1 C403.2,13,1 (efficiency) and OSA cfms and operating hours for all air systems;identify heating and cooling equipment that does not have a corresponding WSEC minimum efficiency(manufacturer rated) List all motors>_1/12 hp(that are not integral to a rated piece of equipment)in the mechanical INA C405.8 or electrical equipment schedules on plans;indicate hp,rpm,number of poles and rated C403.2.14 Electric motor efficiency efficiency,or exception applied For fractional hp motors(1/12-1 hp),indicate whether they are an electronically commutated INA motor,have rated efficiency of at least 70%,or exception taken For all HVAC fan systems that provide heating and/or cooling,provide system total Yes nameplate hp in MECH-FANSYS-SUM form C403.2.11.1 Fan power limitation For all applicable HVAC systems with total fan motor hp>5hp,verify fan system motor hp or INA bhp complies with fan power limits per equations in Table C403.2.11.1(1),provide MECH- FANSYS form for each system NA C403 2 11 2 Motor nameplate hp For all applicable HVAC systems with total fan motor hp>5hp,indicate fan motors specified are the smallest available motor hp size greater than fan bhp,note exceptions taken For all applicable HVAC systems with total fan motor hp>5hp,identify in equipment schedule C403.2.11.3 Fan efficiency all fans required to comply with fan efficiency grade and indicate rated FEG is z 67,or exception taken;indicate these fans are sized so total efficiency is within 15/o of the fan maximum total efficiency C403.2 11.4 Group R occupancy For all exhaust fans<400 cfm in Group R occupancies,indicate in equipment schedule the exhaust fan efficacy fan flow rate and efficacy(cfmlwatt),or exception taken;refer to Table C403.2.11.4(CE-57) Variable flow capacity- For fan motors>_7.5 hp,indicate method of variable flow control(VSD or equivalent method)in C403.2-13 fans equipment schedule,or exception taken;for equivalent method for an HVAC system refer to HVAC System Controls for additional requirements C403.2.3 Maximum air cooled chiller For chilled water plants and buildings with>500 tons of cooling capacity,indicate air-cooled capacity chiller capacity is_<100 tons,or exception taken Large capacity cooling For buildings with z 300 tons of cooling capacity,indicate method of multi-stage or variable o C403.4 systems capacity control Imultiple staged compressors,or max capacity of any single unit<66/o of the total) Non-standard water-cooled For water-cooled centrifugal chillers not designed for operation at standard conditions,provide C403-2.3-1 centrifugal chillers calculations documenting maximum full load and part load rated equipment performance equirements C403.2.13.1 Centrifugal fan open-circuit For open-circuit centrifugal fan cooling towers with>_1,100 gpm capacity,indicate cooling C403.4.3.2 cooling towers towers comply with efficiency requirements for axial fan open circuit cooling towers For single boilers with>500,000 Btulh capacity,indicate multi-stage or modulating burner C403-4.2 Large capacity boiler For boiler system(single or multiple)with>1,000,000 Btulh capacity,indicate turndown ratio C403.4.2.5 systems per Table C403.4.2.5 and method(multiple single input boilers,modulating boilers,or combination) Variable flow capacity- For pump motors z 7.5 hp,indicate method of variable flow control(VSD or equivalent C403.2.13 pumps method)in equipment schedule,or exception taken;for equivalent method for a hydronic system refer to Hydronic System Controls for additional requirements C403.2.3 Gas and oil-fired forced air For forced air furnaces with capacity a 225,000 Btulh and all unit heaters,indicate in furnace and unit heaters equipment schedule intermittent ignition or IID,flue or draft damper,and rated jacket loss C403.2.4.6 Combustion heating For combustion heating equipment with output capacity>225,000 Btulh,indicate modulating equipment or staged combustion control C403.2.3.3 Packaged electric heating/ Verify all packaged electric equipment with>6,000 Btu/h cooling capacity and any amount of cooling equipment heating is a heat pump;include in equipment schedules C403 2.12 Heating outside a building Indicate systems providing heating in non-enclosed outdoor occupied spaces are radiant systems;refer to HVAC System Controls for additional requirements C403.2.7.1 Kitchen exhaust hoods Indicate on plans the type,duty and exhaust air rate of each kitchen hood,refer to HVAC System Controls for additional requirements Outdoor supply air,exhaust Indicate locations of OSA intake,and exhaust and relief outlet dampers on plans;indicate C403.2.4.3 and relief dampers Whether dampers are Class 1 motorized,or gravity and exception taken(include leakage rating,cfm/sf);refer to HVAC System Controls for additional requirements for OSA dampers Indicate locations of return air dampers that are integral to economizer operation;verify C403.2.4.3 Return air dampers dampers are motorized;indicate whether dampers are Class 1,or within packaged equipment eligible for leakage rating exception(include leakage rating,cfnI j; / r 2015 Washington State Energy Cede Compliance Forms for Commercial,R2 and R3 over 3 stories and all R1 -Page 2 of 7 Mechanical Permit Plans ChMist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 Project Title: Cumulus Park NE Date 4/3/2017 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code,Commercial Provisions. Applicable Code Section Code Provision Information Required-Must be in permit documents Location in Building Department es.no.nal I I I Documents Notes C403.2.4.3 Stairway and shaft vent Indicate location of stairway and shaft vent dampers on plans;verify dampers are Class 1 dampers motorized:refer to HVAC System Controls for additional requirements For systems serving areas>25,000 sf or spanning more than one floor,that include areas that C403.2.4.4 Zone isolation dampers are expected to be occupied non-simultaneously;identify isolation zone areas on plans and locations of associated isolation dampers in HVAC distribution system;refer to HVAC System Controls for additional requirements For cooling systems with humidification equipment that are also required to have air C403.2.3.4 Humidification economizer,indicate humidifier is adiabatic(direct evaporative or fog atomization),or exception taken Additional Efficiency Package Option,More Efficient HVAC Equipment&Fan Performance- Must comply with all 3 provisions to be eligible C406.2 1 To comply with additional efficiency package option,calculate the percentage of heating and C403,2.3 HVAC system selection cooling equipment in the project(based on output capacity)that do not have a corresponding WSEC listed efficiency:shall be less than 10%to comply C406-2-2 Minimum equipment To comply with additional efficiency package option,indicate that all listed heating and cooling C403,2 3 efficiency equipment have a rated efficiency that exceeds WSEC listed efficiency by at least 15% C406,2 3 To comply with additional efficiency package option,indicate rated FEG of stand alone fans is C403.2.11,3 Minimum fan efficiency �_-71;indicate these fans are sized so the fan efficiency at design conditions is within 10%of the maximum total or static efficient HVAC System Controls Indicate locations of thermostatic and humidity control devices and the zones they serve on Existing plans,including perimeter system zones location Where adjacent(neighboring)zones are controlled by separate thermostats(including perimeter systems used to offset heat gain or loss),and are connected by permanent Thermostatic controls openings>10%of either zone sf area,indicate controls configured to prevent adjacent zones Yes C403.2,4.1 (thermostats and from operating in conflicting modes(one in heat,other in cool);applies to adjacent perimeter humidistats) zones,adjacent nonperimeter zones,and adjacent perimeter and nonperimeter zones If applying Exception 2 to nonperimeter zones adjacent to perimeter zones,indicate that setpoints and deadband settings in these zones are coordinated so cooling in a nonperimeter zone does not occur until the temperature in that zone is 5°F higher than the adjacent perimeter zone temperature in heating C403.2-4A.1 Heat pump supplementary Indicate staged heating operation with compression as the first stage of heating and heat supplemental heating controlled with outdoor lock-out temperature set to 40°F or less C403.2.4.1.2 Deadband Indicate zone thermostatic controls configured with 5°F minimum deadband for systems that Yes control both heating and cooling If separate heating and cooling systems with separate thermostatic control devices are used to Setpoint overlap restriction serve a zone,indicate locations of both thermostatic control devices and the zone they serve C403.2.4.1.3 (thermostats) on plans Indicate a limit switch,mechanical stop or DDC control with programming to prevent simultaneous heating and cooling C403.2 4.2 Indicate zone thermostatic controls configured with required automatic setback and manual Yes C403.2 4.2.1 Automatic setback and override functions,setback temperatures,and control method(automatic time clock or C403.2.4.2,2 shutdown programmable controls);note exceptions taken C403.2.4.2.3 Automatic(optimum)start Indicate system controls that adjust equipment start time required to bring each area served Yes up to design temperature just prior to scheduled occupancy C403.2.4.3 Outdoor supply air dampers Indicate automatic controls configured to close OSA damper during unoccupied equipment Yes operation;not including economizer cooling,night flush or IMC required OSA/exhaust C403.2.4.3 Stairway and shaft vent Indicate method of activation of stairway and shaft vent dampers(fire alarm or interruption of dampers power) For systems serving areas>25,000 sf or spanning more than one floor,that include areas that Yes C403.2 4.4 .Zone isolation controls are expected to be occupied non-simultaneously;indicate controls that allow for independent space conditioning of isolation zones;or exception taken C403.2.12 Heating outside a building Indicate occupancy sensing or timer switch controls configured to automatically shut off Yes heating system when area served is unoccupied C403.2.4.5 Snow melt systems Indicate automatic controls configured to shut off system when pavement temperature exceeds 50°F and no precipitation is falling,and when outdoor air temperature exceeds 40oF C403.2.4.6 Freeze protection system Indicate automatic controls to shut off system when outdoor temperature exceeds 40°F,or Yes controls conditions protect fluid from freezing Group R1 hotel/motel For hotels and motels with over 50 guest rooms,indicate automatic controls serving guest C403 2.4.9 guest rooms rooms that are capable of setback(heating)and set-up(cooling)of temperature setpoint by at least 5°F;indicate control method-activated by room entry or occupancy sensor � � t `-�" 2015 Washington State Energy C^d$Compliance Forms for Commercial,R2 and R3 over 3 stories and all R1-Page 3 of 7 PlansMechanical Permit 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 Project Title: Cumulus Park NE Date 4/3/2017 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code,Commercial Provisions- Applicable Code Section Code Provision Information Required-Must be in permit documents Location in Building Department ( es,no,na Documents Notes Catlyst C403 2.4.10 Group R2/R3 dwelling For primary space conditioning system,indicate 5-2 programmable thermostats capable of two iBMS Yes 11 units,Group R2 sleeping setback periods per day;for all thermostats indicate purpose(heating only,cooling only,or C403 2.4. units both),required temperature range and at minimum a 10°F deadband;or exception taken Indicate method of ventilation air delivery(natural or mechanical)for each zone mech If mechanically delivered,indicate that systems are configured to provide not more than 150% Set C403.2.6 Ventilation of,but at least the minimum required volume of outdoor air to each zone per IMC,ASHRAE C403.2.11.4 62.1 or other applicable code(WAC,OSHA,etc);or exception taken If delivered via natural ventilation,identify required elements per IMC including minimum openable area to the outdoors or qualifying adjoining spaces Identify spaces>500 sf with occupant load>25 people/1,000 sf per IMC;for each space Catalyst Demand controlled indicate whether it is served by an HVAC system with total design OSA>3,000 cfm,and/or Yes C403.2.6,2 the system has airside economizer or automatic modulating OSA damper;indicate OSA ventilation controls are configured to provide demand controlled ventilation or provide supporting documentation for applied exception For gyms,classrooms,auditoriums and conference rooms>500 sf,indicate occupancy-based C403.2-6.3 Occupancy sensors OSA control when space is unoccupied and method(closes OSA damper or shuts-off equipment);or alternate means provided to automatically reduce OSA when space is partially occupied C403.2.6.4 Enclosed loading dock For enclosed loading docks,indicate ventilation/exhaust system method of activation(gas C403.2.6.4.1 ventilation detection system for CO and NO2,or occupancy sensors),and control method(staged or modulating) C403.2.6.4 Enclosed parking garage For enclosed parking garages,indicate ventilation/exhaust system activated by gas detection C403 2.6.4.2 ventilation system for CO and NO2,and control method(staged or modulating);or exception taken Provide calculations that show a balanced accounting of total kitchen exhaust(include all hoods)with%of:supply air,transfer air from adjacent spaces,and make-up air;if applicable, C403.2.7.1 Kitchen exhaust hoods indicate that direct make-up air to each hood does not exceed 10%of hood exhaust For kitchens with total hood exhaust exceeding 2,000 cfm,indicate exhaust air rate per Table C403.2.7.1 and compliance method(DCV,energy recovery,or transfer air that would otherwise be exhausted) C403 2 7.2 Laboratory exhaust systems Refer to Systems Requiring Energy Recovery for requirements 'Variable flow capacity- For HVAC fan motors z 7.5 hp,indicate method of variable flow control(VSD,or equivalent C403.2.13 iHVAC system fans control method that reduces design air volume by 50%at 1/3 static design pressure);note exception taken DX air handler variable For DX air handlers with economizer and cooling capacity>_65,000 Btulh,indicate number of cooling control cooling stages provided and method(multiple compressors and/or variable speed C403 3-1 (Under Integrated compressors);indicate minimum displacement(capacity reduction)as/o of full load 2-70/30 Economizer) Indicate control method(cooling capacity controlled in response to space temperature,space temperature controlled by modulating supply airflow,or both) Catalyst For DX air handling units with cooling capacity t 65,000 Btu/h and evaporative and chilled water air handling units with fan z 0.25 hp,indicate whether system is single zone or multiple zone and related control method(cooling capacity controlled in response to space temperature,space temperature is controlled by modulating supply airflow,or both) multizone For mechanical cooling systems(includes DX and chilled water coils)that control cooling capacity in response to space temperature-Provide a minimum of two stages of fan control; C403.2.11.5 Fan airflow control indicate minimum fan speed is 5 66%of full speed drawing<_40%of full speed fan power during periods of low cooling or ventilation only 70130 For other mechanical cooling systems(includes DX and chilled water coils)that control space temperature by modulating airflow(in lieu of,or in addition to,controlling capacity in response to space temperature)-Provide fan controls for modulating supply airflow;indicate minimum fan speed is 5 50%of full speed drawing 5 30%of full speed fan power during periods of low cooling or ventilation only;or exception taken Provide central and zone level DDC controls as required based on system application, C403.2.4.12 DDC system capabilities capacity or size thresholds and other qualification per Table C403.2.4.12.1 Identify all DDC system input/output control points;indicate capability for trending and ra hical dis la Ducting Systems C403.2 8.1 Indicate on plans that all ductwork is constructed and sealed per IMC C403.2,8.3 Duct construction For OSA ductwork,also indicate on plans that ductwork meets air leakage requirements per C402.5 and vapor retarder requirements per the IBC C403.2.8.3 Duct pressure Identify location of low,medium and high pressure ductwork on plans classifications C403.2.8 3.3 High pressure duct leakage Indicate high pressure duct leakage testing requirements on plans;provide test results to test jurisdiction when completed t � r � � 1 2015 Washington State Energy Code Compliance Forms for Commercial,R2 and R3 over 3 stories and all R1-Page 4 of 7 PermitMechanical 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 Project Title: Cumulus Park NE iDate 4/3/2017 The following Information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code,Commercial Provisions. Information Required-Must be in permit documents Location in Building Department Applicable Code Section Code Provision es.no,na Documents Notes For supply and return ductwork located in unconditioned space or outdoors,indicate R-value of insulation on ductwork on plans;identify climate zone;note exceptions taken C403.2.8.1 For supply ductwork located in conditioned space,identify if design supply temperature is< C403.2.8,2 Duct insulation 55°F or>105°F and indicate R-value of insulation on this ductwork on plans;note exception taken For OSA ductwork,shafts and plenums,indicate R-value of insulation on these elements on tans per Table C402.1 3 for steel-framed walls;note exception taken Piping Systems C403.2.9 Piping insulation Indicate design temperature range of fluid conveyed in piping and thickness of insulation(in inches)on hydronic piping plans;or exception taken C403.2.9.1 Piping insulation exposed to Indicate method of protection of pipe insulation from damage/degradation on hydronic piping weather plans Economizers Identify in equipment schedules on plans or in MECH-EQ forms all cooling systems requiring air economizer controls yes C403.3 Air economizer required Provide MECH-ECONO form indicating systems utilizing air economizer exceptions,including those with water-side economizer in lieu of air economizer;indicate on plans eligible exception(s)taken and measures to comply with exception(s) Yes C403.3,1 Integrated economizer Indicate air and water-side economizers are configured for partial cooling operation even operation-air and water where additional mechanical cooling is required to meet the load C403.3.2 Economizer heating system Verify control method of HVAC systems with economizers does not increase building heating impact-air and water energy usage during normal operation C403.3.3.1 Air economizer capacity Indicate modulating OSA and return air dampers are configured to provide up to 100%OSA for cooling Verify mechanical cooling controls are interlocked with air economizer controls so the outside C403.3.1 air damper remains in 100%open position when mechanical cooling is also required to meet C403.3.3.2 Integrated air economizer 'the cooling load,until the leaving air temperature is<45°F For systems with cooling capacity>_65,000 Btu/h,verify that control of economizer dampers is not based only on mixed air temperature;or exception taken C403 3.3.3 Air economizer high limit Indicate high limit shut-off control method and required high limit per Table C403.3.3.3 'controls For eligible systems where water-side economizer may be provided in lieu of air economizer, C403.3 4-1 'Water economizer capacity indicate system is capable of 100%design cooling capacity at 50°F db/45°F wb OSA temperatures C403.3.4.2 Water economizer Indicate pressure drop across precooling coils and heat exchangers in water economizer maximum pressure drop system do not exceed pressure drop limit C403 3-1 DX air handling equipment For DX air handlers with economizer and cooling capacity z 65,000 Btu/h,refer to HVAC control System Controls for requirements DX equipment economizer For DX air handlers with economizer and cooling capacity z 54,000 Btu/h,provide a fault C403-2.4.7 fault detection and detection and diagnostics(FDD)system to monitor economizer system operation and report diagnostics faults Systems Requiring Energy Recovery For systems with design OSA>5,000 cfm,or design supply air cfm and%OSA exceeding the values in Tables C403.5.1(1)or(2),indicate exhaust air ER method;or exception taken with Energy recovery(ER)- supporting calculations Under 5K C403.5.1 ventilation/exhaust For rooms served by multiple systems with aggregate design OSA>5,000 cfm,or aggregate systems design supply air cfm and%OSA exceeding the values in Tables C403.5.1(1)or(2),indicate exhaust air ER method;or exception taken with supporting calculations Indicate ER rated effectiveness that increases OSA enthalpy by z 50%based on delta between OSA and return air enthalpies at design conditions Laboratory exhaust systems For buildings with total lab exhaust>5,000 cfm,indicate method of energy recovery used to C403.2.7.2 (energy recovery) pre-condition laboratory make-up air;ER effectiveness(min 25°F);or alternative method per exception(VAV exhaust,semi-conditioned makeup,or CERM calculation) For buildings with pools or spas with water surface area>200 sf,indicate exhaust air ER C404.10.4 Pools and permanent spas method and use of waste heat(preheat ventilation air,pool water or service hot water);or (under exhaust systems exception taken C404.11) (energy recovery) Indicate ER system has the rated effectiveness and is configured to decrease the exhaust air temperature at design conditions by z 36°F Energy recovery- For buildings with on-site steam heating systems,indicate condensate water ER C403.5.2 steam condensate systems For buildings that use off-site generated steam where condensate is not returned to the source,indicate on-site condensate water ER 2015 Washington State Energy C-ale Compliance Forms for Commercial,R2 and R3 over 3 sinries and all R1-Page 5 of 7 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 Project Title: Cumulus Park NE Date 4/3/2017 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code,Commercial Provisions. Applicable Code Section Code Provision Information Required-Must be in permit documents Location in Building Department es,no,na Documents Notes For buildings with food service,meat or deli departments that have z 500,000 Btu/h of remote refrigeration capacity for coolers/freezers,indicate condenser ER and use of captured energy (service water heating,space heating,or dehumidification reheating) C403.5.3 Energy recovery- cooler/freezer condensers For buildings with z 40,000 sf conditioned floor area and with 2 1,000,000 Btu/h of remote refrigeration capacity for coolers/freezers,indicate condenser ER and use of captured energy for service water heating and also for space heating,or dehumidification reheating For buildings with 24-hour operation and with>1,500,000 Btu/h of heat rejection capacity and C403 5.4 Energy recovery- design service hot water load>250,000 Btu/h,indicate condenser ER to pre-heat service condenser systems water;or exception taken.Provide calculations showing the amount of recovered heat that is utilized(60%of peak heat rejection load or pre-heat service water to 85°F). Hydronic System Controls For hydronic system pump motors a 7.5 hp,indicate method of variable flow control(VSD or C403.2 13 Variable flow control- equivalent method that requires z 30%design wattage at 50%design fluid flow);note C403.4,2 7 hydronic system pumps exception taken Identify whether hydronic coils have DDC controls and associated manner of pump speed control(differential pressure,zone hydronic demand,etc) For boilers that provide building heating,indicate controls that provide heating water temperature setback based on outdoor temperature For heating and chilled water systems z 300,000 Btu/h,indicate systems are configured to C403.2 5 Hydronic system setback automatically reset supply water temperature based upon demand;or exception taken. o C403 4 5 and part load controls If system pump motor hp z 3 hp,also indicate controls automatically reduce flow by z 50/o. For chilled water systems(>_300,000 Btulh,pump motor hp z 3 hp)that serve water-cooled unitary air conditioners,indicate VSD or staged pumps in chilled water system and heat rejection loop that reduce pump flow so that one control valve is nearly wide open,or to maintain a minimum differential pressure;or exception taken C403.4.2 I Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers C403.4.6 Hot gas bypass limitation For cooling equipment with hot gas bypass,provide either multiple step unloading or continuous capacity modulation;indicate bypass capacity per Table C403 4.6 C403.4.2.2 Two-pipe changeover Indicate changeover deadband(min 15°F),heating/cooling mode scheduling and systems changeover temperature range(limit 30°F) C403.4.2.6 'Chiller/boiler plant pump Indicate controls are configured to automatically reduce overall plant flow and shut-off flow Bsolation through individual chillers and boilers when not in use For cooling towers with fan motors>_7.5 hp,indicate VSD and method to adjust fan speed C403.2.13.1.1 Heat rejection equipment- (adjusted based on leaving fluid temperature or condenser temperature/pressure of heat C403.4.3.1.1 variable flow control rejection device) C403.4.3.1.2 For multiple-cell heat rejection equipment with VSD,indicate controls that ramp all fans in unison C403.4.3.3 Heat rejection equipment- Indicate open-circuit cooling towers with multiple pumps or VSD control are designed so all cooling tower flow turndown cells can be run in parallel C403.4.2.3 1 Water loop heat pump- Indicate capability of central equipment to provide minimum 20°F water supply temperature deadband deadband between heat rejection and heat addition modes;or exception taken Water loop heat pump- Indicate type of cooling tower(open-or closed-circuit)in equipment schedule;indicate method C403.4.2.3.2.1 heat rejection equipment, used to limit system heat loss when heat rejection is not needed Zone 4 Water loop heat pump- For open-or closed-circuit cooling towers,provide a heat exchanger that separates the cooling C403 4 2.3.2.1 heat rejection equipment, tower and heat pump loop one 5 C403A 2 3-3 Water loop heat pump- For hydronic heat pump systems with total system power>10 hp,indicate 2-way isolation isolation valves I valves on each heat pump and variable flows stem control Dedicated Outdoor Air Systems(DOAS)-Optional through 6/30/16,Prescriptive 7/1/2016 For buildings with office,retail,education,library and fire station spaces,identify these spaces C403,6 Dedicated outdoor air on plans;indicate that ventilation air in each occupied space is provided via a DOAS system; C403.6.3 systems or document compliance with C403.6.3 Impracticality;or exception taken(buildings complying with C402.4-1.4 or C406.6 may not utilize exceptions) Energy recovery ventilation For all DOAS systems,indicate exhaust air ER method;or exception taken with supporting C403.6.1 calculations Indicate ER rated effectiveness that increases OSA enthalpy by>_50/o based on with DOAS delta between OSA and return air enthalpies at design conditions. Indicate equipment associated with the delivery of zone level heating and cooling(fans, Heating/cooling system hydronic pumps,primary air dampers,etc)are configured to shut off,and central equipment is C403.6.2 controls with DOAS configured to turn down,when there is no call for heating or cooling in the zone they serve If applying Exception to heating/cooling fans used for air mixing in the space during deadband periods,include fan watts per cfm in equipment schedule t �"� � � � `.� .._ 2015 Washington State Energy Code Compliance Forms for Commercial,R2 and R3 over 3 gis�ries and all R1-Page 6 of 7 PermitMechanical 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 Project Title: Cumulus Park NE IDate 4/3/2017 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code,Commercial Provisions. Applicable Code Section Code Provision Information Required-Must be in permit documents Location in Building Department es,no,na Documents Notes E Increased prescriptivemaximum vertical Indicate that all occupied,conditioned spaces are served by a DOAS per C403.6 fenestration area with DOAS Additional Efficiency Package Option,Dedicated Outside Air Systems(DOAS) C406.6 Building provided with To comply with additional efficiency package option,indicate that 90%or more of all occupied, DOAS I conditioned spaces are served by a DOAS per C403.6 Multiple Zone Air Systems JAir systems serving multiple Identify supply air systems serving multiple zones and the zones they serve on plans;indicate C403.4.4 whether system is VAV and method of primary air control;or provide supporting zones documentation for applied exception to VAV Yes Provide equipment schedules on plans or MECH-EQ form that list all VAV air terminals and Existing types location VAV systems serving For each air terminal include:maximum airflow rates for primary supply air during zone peak C403AA multiple zones heating and zone peak cooling;maximum airflow during reheating,retooling or mixing; minimum airflow rate to maintain required ventilation,and the basis for these values;if IMC or ASHRAE 62.1 multiple zone equation is basis for minimum flow rates,provide calculation on Existing plans location C403.4.4.1 Single duct VAV terminal Indicate single duct terminal units are configured to reduce primary supply air before reheating units or retooling NA C403.4.4.2 'Dual duct systems-terminal For systems with separate warm air and cool air ducts,indicate terminal units are configured to units reduce the flow from one duct to minimum before mixing with air from the other duct NA Indicate locations of duct static pressure sensors on plans;include at least one sensor per major duct branch;verify controller setpoint pressure at each sensor is<_1.2 inch w.g. catalyst C403.4.1.1 VAV system static pressure sensors- For systems with zone level DDC,indicate controls are configured to monitor zone damper C403.4.1.2 sensors and DDC set points positions and reset static pressure setpoint based on the zone requiring most pressure; include control logic that automatically detects and generates an alarm if any zone excessively drives reset logic,and allows building operators to exclude zones from reset logic Multiple-zone VAV system For systems with zone level DDC controls,indicate controls are configured to automatically C403.4.4 3 ventilation optimization reduce outdoor airflow in response to changes in system ventilation efficiency;or exception controls taken C403.4.4.4 VAV system supply air reset Indicate controls automatically reset supply air temperature in response to building loads or outdoor air temperature:or exception taken Multiple Zone HVAC Systems,High Efficiency VAV-Required for systems utilizing C403.6 DOAS Exception 2,must comply with all 16 provisions C403 7. Air economizer Indicate system is configured for 100%air economizer operation and complies with all related Item 1 economizer requirements per C403.3(without economizer exceptions) C403.7, Direct digital controls(DDC) Provide DDC controls for all components of system;identify all DDC system input/output Item 2 control points;indicate capability for trending and graphical display For systems with minimum OSA>2,500 cfm,indicate outdoor airflow monitoring station that C403.7, Outdoor airflow measures OSA intake under all load conditions;indicate control sequence that increases or Item 3 measurement and reduction reduces system OSA cfm based on VAV terminal feedback of ventilation efficiency(per C403,4,4.3 without exceptions)or DCV(per C403.2.6 2) C403.7, For systems with minimum OSA>2,500 cfm,indicate supply airflow monitoring station Item 4 Supply airflow measurement capable of measuring supply air delivered to VAV terminals under all load conditions C403.7. Zone isolation and Verify maximum area served by a single HEVAV system is<_50,000 sf,or one entire floor, Item 5 maximum area served whichever is greater;in addition if a system serves>25,000 sf,that includes areas that are expected to be occupied non-simultaneously,indicate zone isolation controls per C403.2.4.4 C403 7, Interior/exterior zone Verify that VAV terminals serving interior cooling driven loads are sized per design supply air Item 6 design supply air temperature that is 5°F higher than VAV terminals serving exterior zones temperature C403.7, Maximum air terminal inlet Identify air terminals with minimum primary airflow setpoints>50%of maximum setpoint in Item 7 velocity equipment schedule or MECH-EQ form;indicate air terminal inlet velocity does not exceed 900 fpm C403 7, Indicate DDC system sequences of operation are designed and configured per ASHRAE GPC Item 8 Sequence of operation 36 C403.7, Maximum allowable system Verify fan system bhp is 5 90%of the bhp limit per Option 2 equation in Table C403.2.1 I.1(1). Item 9 brake horsepower provide MECH-FANSYS form for each system Indicate all series and parallel terminal fans have electronically commutated motors;indicate C403.7, Fan-powered terminal unit DDC control system is configured to vary air terminal fan speed as a function of the load; Item 10 motor and control indicate fan speed during periods of low heating,low cooling,or ventilation only is 5 66%of peak design air flow or provide supporting documentation for applied exception 2015 Washington State Energy Cale Compliance Forms for Commercial,R2 and R3 over 3 stories and all R1 -Page 7 of 7 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 Project Title: Cumulus Park NE Date 4/3/2017 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code,Commercial Provisions Applicable Code Section Code Provision Information Required-Must be in permit documents Location in Building Department es,no,na Documents Notes C403 7. Application of single duct Indicate VAV terminal types on plans;verify fan-powered terminal units only serve perimeter Item 11 and fan-powered terminal zones with envelope loads;verify all other zones are served by single duct terminal units units C403.7, Fan-powered terminal unit Indicate DDC controls are configured to automatically reset the primary supply air cfm setpoint Item 12 primary air reset of all fan-powered terminal units to the minimum required to maintain ventilation during occupied heating or deadband,based upon the VAV air handling unit OSA ventilation fraction For spaces>150 sf with occupant density z 25 people/1000 sf,indicate space is served by a C403.7, High occupancy space dedicated terminal unit with DCV control that resets terminal unit ventilation setpoint;also Item 13 controls indicate occupancy sensor control that automatically reduces minimum ventilation to zero and sets back room heating and cooling setpoints by z 5°F For server,electronic equipment,telecom or similar spaces with cooling loads>5 W/sf, C403.7, Dedicated HVAC systems 'indicate spaces are served by independent HVAC systems that are separate from HPVAV Item 14 systems serving rest of building;indicate dedicated HVAC systems have air economizer controls or energy recovery per C403 3 Exception 9 Indicate whether systems are served by a high efficiency heating water plant,or a high efficiency chilled water plant If complying via high efficiency heating water plant:Indicate all VAV terminals have hydronic heating coils served by heating water system with either gas-fired boiler(s)with thermal C403 7, Central plant efficiency efficiency z 90%,air-to-water heat pumps,or heat recovery chillers Item 15 If complying via high efficiency chilled water plant:Indicate all VAV air handlers have cooling coils served by chillers with rated IPLV efficiency that exceeds WSEC listed IPLV by at least 25%per Table C403.2.3(7)(note water-cooled IPLV is max,all others are min);indicate smallest chiller or compressor in plant is<_20%of total plant capacity,or provide thermal storage sized for<20%of total plant capacity C403 7, Fault detection and Indicate DDC system includes a fault detection and diagnostics(FDD)system configured to Item 16 diagnostics monitor operation and provide fault reporting of required parameters for all VAV air handlers and VAV air terminal units in the HPVAV system HVAC Equipment Energy Use Metering HVAC equipment energy For new buildings>50,000 sf and building additions>25,000 sf,verify energy use metering of C409.3.1 all equipment used to provide space heating and cooling,dehumidification and ventilation will use metering be provided per C409;indicate equipment eligible for exception Documentation and System Specific Requirement To Support Commissioning Indicate that all mechanical systems,equipment,and controls for which the WSEC requires control functions and /or configuration to perform specific functions are required to be C408.2 Scope of mechanical commissioned; systems commissioning For buildings with z 240,000 Btu/h total output cooling capacity or z 300,000 Btu/h total output heating capacity,indicate that all mechanical systems regardless of individual capacity are required to be commissioned;or provide building heating/cooling capacity calculation demonstrating eligibility for exception Indicate in plans and specifications that Cx per C408 is required for all applicable mechanical systems; C403 2,10 Include general summary with at a minimum of Items 1 thru 4 of the Cx plan per C408.1.2 C408.1.1 Commissioning including:narrative description of activities,responsibilities of the Cx team,schedule of C408.1.2 requirements in construction activities including verification of project close out documentation per C103.6,and conflict of C408.1.4.2 documents interest plan(if required); C103.6 Include in general summary that a Cx project report or Compliance Checklist(Figure C408-1.4.2)shall be completed by the Certified Cx Professional and provided to the owner prior to the final mechanical inspection Air system and hydronic Indicate in plans that air and fluid flow rates shall be tested and balanced within the tolerances C408.22 system balancing defined in the specifications;indicate systems shall be balanced in a mannerto first minimize 'throttling losses,then adjusted to meet design flow conditions C408.2.2.1 Air system balancing Indicate devices that provide the capability to balance all supply air outlets,zone terminals and devices air handling equipment requiring system balancing C408.22.2 Hydronic system balancing Indicate devices that provide the capability to isolate,balance and measure flow across all devices hydronic equipment requiring system balancing including heating and cooling coils and pumps C408.2-3 Functional performance Identify in plans and specifications the intended operation of all equipment and controls during testing criteria all modes of operation,including interfacing between new and existing-to-remain systems Project Close Out Documentation Documentation and project Indicate in plans that project close out documentation and training of building operations C103.6 close out submittal personnel is required for all mechanical components,equipment and systems governed by requirements this code;indicate close out documentation shall include:record documents,O&M manuals, applicable WSEC compliance forms and calculations a r i } �� 2015 Washington State Energy rode Compliance Forms for Commercial, R2 any+ R3 over 3 stories and all R1 • ' • ' TrIM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 Project Title: Cumulus Park NE Date 4/3/2017 For Building Dept. Use HVAC Air Distribution System Schedule List all HVAC systems that have the capability to provide heating and/or cooling to the spaces they serve. Fan Power System or System Total Calculation Primary Supply Speed Control Description Nameplate HP Required Fan ID (Note 1) (Note 2) (Note 3) (Note 4) Unit 1 Cv Supply fan included in equipment cut sheet 3 No Note 1-Constant Volume(CV), Variable Air Volume(VAV),or Hospital/Lab CV system that qualifies for VAV budget per C403.2.11 1 Exception 1. Single zone VA systems shall comply as CV. Note 2-Describe system type and list all fans(or groups of fans)associated with the delivery and removal of conditioned air by the system.Include all supply,return/relief,exhaust and exhaust hoods(>1 hp), make-up air,dedicated outside air(DOAS),booster fans,and series fan-powered terminals. VA parallel fan-powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak conditions Note 3-Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air by the system. Note 4-This form automatically identifies whether a MECH-FANSYS form is required to demonstrate compliance with the fan power allowance(Yes), or this information is not required because the system has a combined total nameplate motor hp that is 5 hp or less(No) MECH-FANSYS Forms A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 5 hp. Select(Add Fan System Form)to generate an additional form. Added forms can be deleted with button in cell E32 of the added form. Model Number YSD180F3RLA**POOOOOOOOIAOBOOOOOO00000000 Customer: Evergreen State Sheet Metal Project: Name : Cumulus Park NE M-2 Unit function Gas/Electric Unit efficiency Standard efficiency Unit controls Reliatel Design Airflow 6000 cfm Evaporator Rows 3 Fresh air selection Low leak econ,comp enthalpy w/ bar ref Evaporator Face Area 26.00 sq ft Evaporator Fin Spacing 180 Per Foot Evaporator Face Velocity 231 ft/min Tonnage 15 Ton Airflow Downflow Min.Unit Operating Weight 1793.0 lb Max Unit Operating Weight 2215.0 lb Cooling Entering Dry Bulb 80.00 F Cooling Entering Wet Bulb 67.00 F Rated capacity(AHRI) 176.00 MBh Ent Air ReI Humidity 51.08% ASHRAE 90 1 Yes Ambient Temp 95.00 F Heating capacity Gas Heat-Low Heating EAT 70.00 F Voltage 208-230/60/3 Design ESP 0.500 in H2O Major design sequence F-R-410A with Microchannel CoolingMain Tonnage 15 Ton Cooling Entering Dry Bulb 80.00 F Cooling Entering Wet Bulb 67.00 F Ent Air ReI Humidity 51.08% Ambient Temp 95.00 F Evap Coil Leav Air Temp(DB) 58.53 F Evap Coil Leav Air Temp(WB) 56.98 F Cooling Leaving Unit DB 60.15 F Cooling Leaving Unit WB 57.60 F Gross Total Capacity 186.05 MBh Gross Sensible Capacity 139.09 MBh Gross Latent Capacity 46.96 MBh Net Total Capacity 177.68 MBh Net Sensible Capacity 130.72 MBh Net Sensible Heat Ratio 0.74 Number Fan Motor Heat 8.38 MBh Dew Point Temp 55.97 F Refrig charge(HFC-410A)-ckt 1 11.4 lb Refrig charge(HFC-410A)-ckt 2 6.0 lb Saturated Discharge Temp Circuit 1 120.76 F Saturated Suction Temp Circuit 1 49.88 F Saturated Discharge Temp Circuit 2 118.58 F Saturated Suction Temp Circuit 2 51.29 F Main Heating Output Htg Capacity 200.00 MBh Output Htg Capacity w/Fan 208.38 MBh Heating EAT 70.00 F Heating LAT 100.72 F Heating Temp Rise 30.72 F Pagel Voltage 208-230/60/3 Field Supplied Drive Kit Required None Design ESP 0.500 in H2O Component SP Add 0.330 in H2O Total Static Pressure 0.830 in H2O Indoor Mtr.Operating Power 2.66 bhp Indoor RPM 683 rpm Indoor Motor Power 1.98 kW Outdoor Motor Power 0.95 kW Compressor Power 13.92 kW System Power 16.85 kW EER @ AHRI Conditions 11.0 EER MCA 75.00 A MOP 100.00 A Compressor 1 RLA 31.90 A Compressor 2 RLA 17.60 A Condenser Fan FLA 3.20 A Evaprator Fan FLA 10.60 A Exhaust fan power 0.56 kW IEER Rating 12.20 Field installed accessories Retrofit wall plate Retrofit wall plate DX cooling Refrigeration controls Frostat Smoke detector Return air smoke detector System monitoring controls-2 Economizer Fault Detection Diagnostics Page 2 Y4V Cumulus Park NE MME Tag Y4V-2 Quantity 1 Model number YSD180F3RLA**P0000000 01A01300000000000000 Unit Information Tonnage 15 Ton Unit function Gas/Electric Min. Unit Operating Weight 1793.0 lb Max Unit Operating Weight 2215.0 lb Design Airflow 6000 cfm Cooling Information Gross Total Capacity 186.05 MBh Gross Sensible Capacity 139.09 MBh Gross Latent Capacity 46.96 MBh Net Total Capacity 177.68 MBh Net Sensible Capacity 130.72 MBh Net Sensible Heat Ratio 0.74 Number Cooling Entering Dry Bulb 80.00 F Cooling Entering Wet Bulb 67.00 F Cooling Leaving Unit DB 60.15 F Cooling Leaving Unit WB 57.60 F Ambient Temp 95.00 F I Heating Information Heating capacity Gas Heat-Low Output Htg Capacity 200.00 MBh Output Htg Capacity w/Fan 208.38 MBh Heating EAT 70.00 F Heating LAT 100.72 F Motor/Electrical Information Voltage 208-230/60/3 Design ESP 0.500 in H2O Indoor Motor Power 1.98 kW Indoor Mtr. Operating Power 2.66 bhp Indoor RPM 683 rpm Outdoor Motor Power 0.95 kW Compressor Power 13.92 kW System Power 16.85 kW MCA 75.00 A MOP 100.00 A Compressor 1 RLA 31.90 A Compressor 2 RLA 17.60 A Evaprator Fan FLA 10.60 A Condenser Fan FLA 3.20 A ASHRAE 90.1 Yes Refrig charge(HFC-410A)- 11.4 lb Refrig charge(HFC-410A)- 6.0 lb ckt 1 ckt 2 Compressor Power 13.92 kW Outdoor Motor Power 0.95 kW Rated capacity(AHRI) 176.00 Exhaust fan power 0.56 kW Indoor Mtr. Operating Power 2.66 bhp SEER @ AHRI Page 1 of 2 i Y4V Cumulus Park NE M WE' Tag Y4V-2 Quantity 1 Model number YSD18OF3RLA**P0000000 01AOB000OOOOOOOOOOO Page 2 of 2 Page 4 NOTES: 2.THRU-THE-BASE GAS AND ELECTRICAL IS NOT STANDARD ON ALL UNITS.(SELECTED OPTION:SEE ACCESSORY SHEET) 3.VE RIFYWEIGHT,CONNECTION,AND ALLDIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION 54" 0 1' 6 13116" DOWNFLOW CONDENSATE O D RAI 11 CON N 1"N P T 26 3/4' 6" 6411116' GAS CONNECTION(SEE NOTE 1) 3211116' 121 11118' 815116"- j (UNIT HOLE(UNIT CONTROL WIRE) 84 3116" 211/1fi 2"DIA HOLE (UNIT POWER WIRE) PACKAGED GASIELECTRIC-DOWNFLOW ISOMETRIC DRAWING 4114"--�-I '-1511 a" 28 314" 26 7/16" 4114" I I I I I I I I I I I I I 1 I I I 1 I I I I I I I i I I I 1 I I I I I 681111T 1 765116" 1 I SUPPLY I I RETURN I I I I I I I I I I I I I I I 1 I I I I I I I I I I I I I 1 I I I � PACKAGED GAS/ELECTRIC-DOWNFLOW PLAN VIEW DRAWING Page 5 =� rRAwF ELECTRICAL/ GENERAL DATA GENERAL PERFORMANCE Standard Motor (1)(3) 1.lodel(Tan): YSD180F(15A) Minimum CircuitAmpacity: 75.0/75.0 U nil 0 peraling Voltage Range. 187-253 Maximum Fuse Size: 100.0/100.0 U nit P rim ary Voltage: 208 M aximum(HAC R)Circuit B reaker: 10D(V100,0 Unit Secondary Vo Ila ge: 230 Unil Hertz: 60 Oversized Motor 0)(4) Field Installed Oversized Motor Unit Phase: 3 MCA: NIA MCA N/A M FS: NIA M FS: II/A EER:(5) 11 0 MCB(HACR): NIA MCB(HACK): N/A GAS HEATING COMPRESSOR H eatin g M ode Is: Low C ircu it(s) Heating and 1 Stage Input(Btu/h) 250,00/175,000 Number. 2 Heatin g and 1 Stage Output(Btufh): 203,000 1142,000 Horsepower: 8 6/4 75 Min./Max-Gas Input- Phase: 3 Pressure Natural or LP: 2 5114 0 Rated Load Amps: 31 9117 6 Gas ConnectionPipeSize: 1/2' Locked RotorAmps: 267.01123.0 INDOOR MOTOR Oversized Motor (4) Field Installed Oversized Motor (4) Plumber: {3) 1 Number: N/A Number: NIA Horsepower: 3.00 Horsepower NIA Hp: NIA M01Dr Speed(RPM): 1,74D Motor Speed(RP M): N/A Motor Speed(RPM): NIA Phase: 3 Phase: N/A Phase: N/A Full LDadAmps: 10.6 Full Load Ain pa: N/A FLA: N/A Locked RotorAmps: 81.0 Locked RotorAmps: NIA LRA NIA OUTDOOR MOTOR POWER EXHAUST COMBUSTION BLOWER (Field Installed Power Exhaust) MOTOR Plumber: 2 Horsepower: NIA (Gas-Fired Heating only) Horsepower: 0-50 Motor Speed(RPM): NIA Horsepower: 0.1 Llaturspeed(RPM): 1.100 Phase: NIA Phase: 1 Full Load Amps: NIA Motor Speed(RP M$ 3,500/2,800 : 1 Full LosdAmps: 32 Lo eked Rotor Amps: N/A phase Full adAmps: 108 L oeked R oto rAm ps: 8.8 Locked R Dt or Am ps: 2.00 FILTER REFRIGERANT m Circuit#1 12 Type: Throwaway Type: R410 Furnished: Yes Factory Charge Number: 414 Circuit#112: 11 4 lb 16 0lb Recommended Size: 2V)20IA2"120'k25'xZ' NOTES: 1.M aximu m(HACR)Circuit Breaker sizing is for installations in the U n iced States only. 2 Refrigerant charge is anapproxim ate value For a more precise value,see unit nameplate and service instructions 3 Value includes oversized motor. 4.Value does not include Power Exhaust Accessory. 5.EER is rated atAH RI conditions and in accordance with DOE test procedures TRINE' 1 v7l�> CLEARANCE 68" (1727.2mm) CLEARANCE 36" CLEARANCE FROM THE (914.4mm) TOP OF UNIT 72" (1828.8mm) P P 1 0 CLEARANCE 6(r C (1524mm) ° CLEARANCE 48" (1219.2mm) DOWN FLOW-PACKAGED GASIELECTRIC CLEARANCE UN IT OUTU NE I � ROOF OPENING 76 1/2" 81" � f DOWN FLOW-PACKAGED GASIELEGTRIGROOF OPENING CLEARANCE Page 7 . 1 M WE' C Base Unit and Corner Weights only 10 Base unit weights Corner Weights Center of G ra vlty SHIPPING NET (D B� Q O E F 0 2384.0I13 1925.D lb 666.E lb 1 595.0 lb 1 343.0 lb 410,0 lb 56" 33" 1_All weights are approximate- 2.The actual weight are listed on the unit nameplate. 3.Refer to unit nameplate and installation guide for weights before scheduling transportation and installation of unit. 4.The weight shown representsthe typica I unit operating weight for the configuration selected.Estimated at+!-10 %oflhenameplate weight.. 0 5 Va rify weig ht,connection,and all dimension with installer documents before installation. 6 Corner weights are given for information only. 7.N et/Shipping weight of optional accessories should be addedto unit weight when ordering factory or field installed accessories Installed Options Net Weight Data g I l Z Accessory Weight CORNER WEIGHT Economizer,Manual and M otorized Outside Air D amper Power Exhaust RaafCurb Oversized M otor HailGuard Hinged Access Doors Po wer C anv.Outlet Through the Base Electrical Circuit Breaker Disconnect Smoke Detector 5.1)Ib Nover Zone Sensor H igh/LowStatic Drive Kit LP Gas Conversion Stainless Steel Heal Exchanger Stainless Steel Drain Pan VFD High EfficiencyMolor 1.Weights for o Pti ans a re a pproxi mate. 2.Weights for options that are not list refer to Installation guide. t V � � 0 PACKAGED GAS/ELECTRIC RIGGI NG AN➢CENTER OF GRAVITY Page 8 ar rAANE' w w N 2 O z O O w O co .P U 4 O LL O a w W d rn ul W (C7 Q w W / Z a a z w O O x w w N_ O z O U w Page 9 AM MANE Page 10 rRANE General The units shall be dedicated downflow or horizontal airflow.The operating range shall be between 115°F and 0°F in cooling as standard from the factory for all units. Packaged Rooftop units cooling,heating capacities,and efficiencies are AHRI Certified within scope of AHRI Standard 340-360(I-P)and ANSIZ21.47 and 10 CFR Part 431 pertaining to Commercial Warm Air Furnaces(gas heating units).Cooling performance shall be rated in accordance with AHRI testing procedures.All units shall be factory assembled,internally wired,fully charged with R-410A,and 100 percent run tested to check cooling operation,fan and blower rotation and control sequence,before leaving the factory.Wiring internal to the unit shall be colored and numbered for simplified identification Units shall be UL listed and labeled, classified in accordance to UL 1995/C 22.2,236-05 3rd Edition. Casing Unit casing shall be constructed of zinc coated,heavy gauge,galvanized steel Exterior surfaces shall be cleaned,phosphatized,and finished with a weather-resistant baked enamel finish.Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM 13117.Cabinet construction shall allow for all maintenance on one side of the unit. In order to ensure a water and airtight seal,service panels shall have lifting handles and no more than three screws to remove All exposed vertical panels and top covers in the indoor air section shall be insulated with a 1/2 inch, 1 pound density foil-faced,fire-resistant,permanent,odorless,glass fiber material The base of the downflow unit shall be insulated with 1/2 inch, 1 pound density foil-faced,closed-cell material.The downflow unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 11/8 inch high supply/return openings to provide an added water integrity precaution,if the condensate drain backs up.The base of the unit shall have provisions for forklift and crane lifting. Unit Top The top cover shall be one piece,or where seams exist,double hemmed and gasket sealed to prevent water leakage. Filters Two inch standard filters shall be factory supplied on all units.Optional two inch pleated media filters shall be available. Compressors All units shall have direct-drive,hermetic,scroll type compressors with centrifugal type oil pumps.Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of nameplate voltage.Internal overloads shall be provided with the scroll compressors All models shall have crankcase heaters, phase monitors and low and high pressure control as standard. Crankcase Heaters These band heaters provide improved compressor reliability by warming the oil to prevent migration during off-cycles or low ambient conditions.These are standard on all Voyager models. Refrigerant Circuits Each refrigerant circuit shall have independent fixed orifice or thermostatic expansion devices,service pressure ports,and refrigerant line filter driers factory installed as standard.An area shall be provided for replacement suction line driers. Evaporator and Condenser Coils Microchannel coils will be burst tested by the manufacturer. Internally finned,5/166 copper tubes mechanically bonded to a configured aluminum plate fin shall be standard for evaporator coils. Microchannel condenser coils shall be standard on all units.Coils shall be leak tested to ensure the pressure integrity.The evaporator coil and condenser coil shall be leak tested to 225 psig and pressure tested to 450 psig.Sloped condensate drain pans are standard. Gas Heating Section The heating section shall have a drum and tube heat exchanger design using corrosion resistant steel components.A forced combustion blower shall supply premixed fuel to a single burner ignited by a pilotless hot surface ignition system In order to provide reliable operation,a negative pressure gas valve shall be used on standard furnaces and a pressure switch on furnaces with modulating heat that requires blower operation to initiate gas flow.On an initial call for heat,the combustion blower shall purge the heat exchanger 45 seconds before ignition.After three unsuccessful ignition attempts,the entire heating system shall be locked out until manually reset at the thermostat.Units shall be suitable for use with natural gas or propane(field installed kit)and shall also comply with California requirements for low NOx emissions.The 12Yz-25 tons shall have two stage heating(Gas/Electric Only). Microchannel coils The microchannel type condenser coil is standard for the TNCD 12.5-25 ton standard efficiency models. Due to flat streamlined tubes with small ports,and metallurgical tube-tofin bond,microchannel coil has better heat transfer performance.Microchannel condenser coil can reduce system refrigerant charge by up to 50%because of smaller internal volume,which leads to better compressor reliability.Compact all-aluminum microchannel coils also help to reduce the unit weight.All-aluminum construction improves re-cyclability.Galvanic corrosion is also minimized due to all aluminum construction.Strong aluminum brazed structure provides better fin protection.In addition,flat streamlined tubes also make microchannel coils more dust resistant and easier to clean.Coils shall be leak tested at the factory to ensure the pressure integrity.The evaporator coil and condenser coil shall be leak tested to 600 psig.The assembled unit shall be leak tested to 465 psig. Outdoor Fans The outdoor fan shall be direct-drive,statically and dynamically balanced,draw-through in the vertical discharge position.The fan motor(s)shall be permanently lubricated and shall have built-in thermal overload protection. Indoor Fan Units above shall have belt driven,FC centrifugal fans with adjustable motor sheaves.Units with standard motors shall have an adjustable idler-arm assembly for quick-adjustment of fan belts and motor sheaves.All motors shall be thermally protected.Oversized motors shall be available for high static application.All indoor fan motors meet the U.S.Energy Policy Act of 1992(EPACT). Controls Unit shall be completely factory wired with necessary controls and contactor pressure lugs or terminal block for power wiring.Unit shall provide an external location for mounting a fused disconnect device.ReliaTel controls shall be provided for all 24 volt control functions The resident control algorithms shall make all heating,cooling, Page 11 = MANE and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures.The control algorithm maintains accurate temperature control,minimizes drift from set point,and provides better building comfort.A centralized control shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection. High Pressure Cutout This option is offered for units that do not have High Pressure cutout as standard. Low Leak Economizer This accessory meets low leak requirements for ASHRAE90.1,IECC,and Title 24 standards;Allows 100 percent outdoor air supply from 0-100 percent modulating dampers;Comes standard with Barometric Relief;can be paired with Powered exhaust for additional building evacuation;Can be paired with Fault Detection(FDD)to meet current mandatory Title 24 requirements;Dry Bulb; And,available for down flow applications. Fault Detection&Diagnostics(FDD This offering meets the mandatory requirement of Title 24. This option provides detection of the following faults: Air temperature sensor failure/fault,not economizing when it should,Economizing when it should not,damper not modulating,and excessive outdoor air. The FDD System shall be certified by the Energy Commission as meeting the requirements Discharge Line Thermostat A bi-metal element discharge line thermostat is installed as a standard option on the discharge line of each system This standard option provides extra protection to the compressors against high discharge temperatures in case of loss of charge,extremely high ambient and other conditions which could drive the discharge temperature higher.Discharge line thermostat is wired in series with high pressure control.When the discharge temperature rises above the protection limit,the bi- metal disc in the thermostat switches to the off position,opening the 24 VAC circuit.When the temperature on the discharge line cools down,the bi-metal disc closes the contactor circuit,providing power to the compressor.When the thermostat opens the fourth time,the ReliaTel control must be manually reset to resume operation on that stage. Defrost Controls Adaptive demand defrost shall be provided to permit defrost wherever coil icing conditions begin to significantly reduce unit capacity. Supply and/or Return Air Smoke Detector With this option installed,if smoke is detected,all unit operation will be shut down.Reset will be manual at the unit.Return Air Smoke Detectors require minimum allowable airflow when used with certain models. See the Installation,Operation,and Maintenance(IOM)manual for the models affected and the minimum allowable airflow required.This option is available on all downflow models. Page 12 o 7 Certificate ®f Product Ratings AHRI Certified Reference Number: 5699387 Date: 3/20/2017 tStatus: Active Product:Year-Round Single-Package Air-Conditioner,Air-Cooled Model Number: YS(D,H)180F(3,4,W)R(H,L,V,X,Z)****0 Manufacturer: TRANE Trade/Brand name:AMERICAN STANDARD;TRANE Series name: VOYAGER II Rated as follows in accordance with AHRI Standard 340/360-2007,Commercial and Industry Unitary Air-Conditioning and Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Refrigerant Used: R-410A Hertz: 60 Cooling Capacity(Btuh): 176000/176000 EER Rating (Cooling): 11.00/11.00 IEER: 12.2/12.2 Heating Capacity at 47F (Btuh): COP at 47F: Heating Capacity at 17F (Btuh): COP at 17F: Full Load Indoor Coil Air Quantity: 5300 The AHRI 340/360 certified EER ratings in Btu/h/W are calculated under the same methodology as the EER ratings at T1 conditions of ISO 5151:2010 and ISO 13253:2011 'Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridlrectory.org. TERMS AND CONDITIONS "Imp This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for Individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; `� entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, so personal and confidential reference. AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we make life better'" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which Is listed at bottom right. ©2014 Air-Conditioning, Heating,and Refrigeration Institute ( CERTIFICATE NO.: 131345034896825667 �� � n rAANE' General The units shall be dedicated downflow or horizontal airflow.The operating range shall be between 115°F and 0°F in cooling as standard from the factory for all units Packaged Rooftop units cooling,heating capacities,and efficiencies are AHRI Certified within scope of AHRI Standard 340-360(I-P)and ANSIZ21.47 and 10 CFR Part 431 pertaining to Commercial Warm Air Furnaces(gas heating units).Cooling performance shall be rated in accordance with AHRI testing procedures.All units shall be factory assembled,internally wired,fully charged with R-410A,and 100 percent run tested to check cooling operation,fan and blower rotation and control sequence,before leaving the factory.Wiring internal to the unit shall be colored and numbered for simplified identification.Units shall be UL listed and labeled, classified in accordance to UL 1995/C 22.2,236-05 3rd Edition. Casing Unit casing shall be constructed of zinc coated,heavy gauge,galvanized steel.Exterior surfaces shall be cleaned,phosphatized,and finished with a weather-resistant baked enamel finish.Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM 13117.Cabinet construction shall allow for all maintenance on one side of the unit.In order to ensure a water and air tight seal,service panels shall have lifting handles and no more than three screws to remove.All exposed vertical panels and top covers in the indoor air section shall be insulated with a 1/2 inch, 1 pound density foil-faced,fire-resistant,permanent,odorless,glass fiber material.The base of the downflow unit shall be insulated with 1/2 inch, 1 pound density foil-faced,closed-cell material.The downflow unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 11/8 inch high supply/return openings to provide an added water integrity precaution,if the condensate drain backs up.The base of the unit shall have provisions for forklift and crane lifting. Unit Top The top cover shall be one piece,or where seams exist,double hemmed and gasket sealed to prevent water leakage. Filters Two inch standard filters shall be factory supplied on all units.Optional two inch pleated media filters shall be available. Compressors All units shall have direct-drive,hermetic,scroll type compressors with centrifugal type oil pumps.Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of nameplate voltage Internal overloads shall be provided with the scroll compressors.All models shall have crankcase heaters, phase monitors and low and high pressure control as standard. Crankcase Heaters These band heaters provide improved compressor reliability by warming the oil to prevent migration during off-cycles or low ambient conditions.These are standard on all Voyager models. Refrigerant Circuits Each refrigerant circuit shall have independent fixed orifice or thermostatic expansion devices,service pressure ports,and refrigerant line filter driers factory installed as standard.An area shall be provided for replacement suction line driers Evaporator and Condenser Coils Microchannel coils will be burst tested by the manufacturer.Internally finned,5/16�,copper tubes mechanically bonded to a configured aluminum plate fin shall be standard for evaporator coils. Microchannel condenser coils shall be standard on all units.Coils shall be leak tested to ensure the pressure integrity.The evaporator coil and condenser coil shall be leak tested to 225 psig and pressure tested to 450 psig.Sloped condensate drain pans are standard. Gas Heating Section The heating section shall have a drum and tube heat exchanger design using corrosion resistant steel components.A forced combustion blower shall supply premixed fuel to a single burner ignited by a pilotless hot surface ignition system In order to provide reliable operation,a negative pressure gas valve shall be used on standard furnaces and a pressure switch on furnaces with modulating heat that requires blower operation to initiate gas flow.On an initial call for heat,the combustion blower shall purge the heat exchanger 45 seconds before ignition.After three unsuccessful ignition attempts,the entire heating system shall be locked out until manually reset at the thermostat Units shall be suitable for use with natural gas or propane(field installed kit)and shall also comply with California requirements for low NOx emissions.The 12'/z-25 tons shall have two stage heating(Gas/Electric Only). Microchannel coils The microchannel type condenser coil is standard for the TNCD 12.5-25 ton standard efficiency models. Due to flat streamlined tubes with small ports,and metallurgical tube-tofin bond,microchannel coil has better heat transfer performance.Microchannel condenser coil can reduce system refrigerant charge by up to 50%because of smaller internal volume,which leads to better compressor reliability.Compact all-aluminum microchannel coils also help to reduce the unit weight.All-aluminum construction improves re-cyclability.Galvanic corrosion is also minimized due to all aluminum construction.Strong aluminum brazed structure provides better fin protection.In addition,flat streamlined tubes also make microchannel coils more dust resistant and easier to clean.Coils shall be leak tested at the factory to ensure the pressure integrity.The evaporator coil and condenser coil shall be leak tested to 600 psig.The assembled unit shall be leak tested to 465 psig. Outdoor Fans The outdoor fan shall be direct-drive,statically and dynamically balanced,draw-through in the vertical discharge position.The fan motor(s)shall be permanently lubricated and shall have built-in thermal overload protection. Indoor Fan Units above shall have belt driven,FC centrifugal fans with adjustable motor sheaves.Units with standard motors shall have an adjustable idler-arm assembly for quick-adjustment of fan belts and motor sheaves.All motors shall be thermally protected.Oversized motors shall be available for high static application.All indoor fan motors meet the U.S.Energy Policy Act of 1992(EPACT). Controls Unit shall be completely factory wired with necessary controls and contactor pressure lugs or terminal block for power wiring.Unit shall provide an external location for mounting a fused disconnect device.ReliaTel controls shall be provided for all 24 volt control functions.The resident control algorithms shall make all heating,cooling, Page 11 Ask 1W T�E" and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures.The control algorithm maintains accurate temperature control,minimizes drift from set point,and provides better building comfort.A centralized control shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection. High Pressure Cutout This option is offered for units that do not have High Pressure cutout as standard. Low Leak Economizer This accessory meets low leak requirements for ASHRAE90.1,IECC,and Title 24 standards;Allows 100 percent outdoor air supply from 0-100 percent modulating dampers;Comes standard with Barometric Relief;can be paired with Powered exhaust for additional building evacuation;Can be paired with Fault Detection(FDD)to meet current mandatory Title 24 requirements;Dry Bulb; And,available for down flow applications. Fault Detection&Diagnostics(FDD This offering meets the mandatory requirement of Title 24. This option provides detection of the following faults: Air temperature sensor failure/fault,not economizing when it should,Economizing when it should not,damper not modulating,and excessive outdoor air. The FDD System shall be certified by the Energy Commission as meeting the requirements. Discharge Line Thermostat A bi-metal element discharge line thermostat is installed as a standard option on the discharge line of each system This standard option provides extra protection to the compressors against high discharge temperatures in case of loss of charge,extremely high ambient and other conditions which could drive the discharge temperature higher.Discharge line thermostat is wired in series with high pressure control.When the discharge temperature rises above the protection limit,the bi- metal disc in the thermostat switches to the off position,opening the 24 VAC circuit.When the temperature on the discharge line cools down,the bi-metal disc closes the contactor circuit,providing power to the compressor.When the thermostat opens the fourth time,the ReliaTel control must be manually reset to resume operation on that stage. Defrost Controls Adaptive demand defrost shall be provided to permit defrost wherever coil icing conditions begin to significantly reduce unit capacity. Supply and/or Return Air Smoke Detector With this option installed,if smoke is detected,all unit operation will be shut down.Reset will be manual at the unit.Return Air Smoke Detectors require minimum allowable airflow when used with certain models.See the Installation,Operation,and Maintenance(IOM)manual for the models affected and the minimum allowable airflow required.This option is available on all downflow models. Page 12 Permit#: 1412 Permit Date: 04/04/17 Permit Type: COMMERCIAL MECHANICAL Project Name: Smokey Point Professional Group Applicant Name: Evergreen State Heat&AC Applicant Address: 2120 Pacific Avenue Applicant, City, State, Zip: Everett Contact: Mark Payne Phone: 425-252-3114 Email: russ@essmwa.com Scope of Work: Replace NE corner 15 ton RTU Valuation: 60000.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 04/07/2017 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Launa Black Property Parcel# Address Legal Description Owner Name Owner Phone Zoning SMOKEY POINT 31052900100800 16410 SMOKEY POINT PROFESSIONAL 651 Medical&Other BLVD Health Services GROUP LLP Contractors Contractor Primary Contact Phone Address Contractor Type License License# EVERGREEN STATE Mark Payne 425-252-3114 2120 Pacific Ave CONSTRUCTION COA 601-724-357 HEAT&A/C CONTRACTOR EVERGREEN STATE Mark Payne 425-252-3114 2120 Pacific Ave CONSTRUCTION Labor&EVERGSS0220T HEAT&A/C CONTRACTOR Industries Plan Reviews Date Review Type Description Assigned To Review Status 04/04/2017 COMMERCIAL Like for like RTU 15 ton. z.Rick Karns MECHANICAL Fees Fee Description Notes Amount Mechanical Commercial Plan Review Table 4-1 $657.59 Total $657.59 Attached Letters Date Letter Description 04/07/2017 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 04/04/2017 Russell Kimbell 64142116 cc $657.59 Outstanding Balance $0.00 Uploaded Files Date File Name 04/07/2017 2205438-1412 Issued Permit.pdf 04/04/2017 2196942-Mechanical Permit Application Clgf2xrdHWMJwv.pdf 04/04/2017 2196943-Mech Specs.xlsm 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary MECH-SUMI 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 Project Information Project Title: Cumulus Park NE Date 4/3/2017 Applicant Information. Provide contact information for individual who can respond to For Building Dept.Use inquiries about compliance form information provided. Company Name: Evergreen State Heat&A/C Company Address: 2120 Pacific Ave,Everett,WA 98201 Applicant Name: Mark Payne Applicant Phone: 425-252-3114 Project Description ❑New Building ❑Building Addition ❑Tenant Improvement 0 System Retrofit ❑No System Changes Briefly describe mechanical systems in Replacing like for like with same capacity,power requirements and gas heat as old unit..old unit provided the text box provided sufficent heating and cooling.Unit is a single phase 5 ton RTU. ❑Total Bldg Performance(TBP) This path includes all mandatory provisions per C401.2 Option 2. MECH-SUM,MECH-CHK,and C407 Energy Analysis forms required. ❑ Load calculation summary [21 MECH-LOAD-CALC Form Design Load Calculations Provide design load calculations for all mechanical systems and equipment serving the building heating,cooling or ventilating needs.If a load calculation summary is provided with the permit documents that includes all applicable compliance information then the MECH-LOAD-CALC form is not required. 0 Mechanical Plans ❑ MECH-EQ Forms(TBD) Mechanical Schedules Indicate location of equipment compliance information.If provided on plans then MECH-EQ forms are not required, however,include on plans all applicable compliance information listed in MECH-EQ tables. ❑ DOAS is required per C403.6 effective July 1,2017(office,retail,education,library and fire station occupancies) All occupied,conditioned areas shall be served by a DOAS that delivers required ventilation air in a manner that does not require space conditioning fan operation.Space conditioning fans cycled off when no heating or cooling is required. Dedicated Outdoor Air ❑ Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS(C403.6,Exception 1) System Requirements and ❑ Ventilation and space conditioning provided by a HEVAV system per C403.7 in lieu of DOAS(C403.6,Exception High Efficiency VAV ❑ DOAS included in project,although not required(occupancy not office,retail,education,library or fire station) Alternate ❑ DOAS related allowances included in project: ❑ Prescriptive vertical fenestration maximum area allowance increased to 40%per C402.4.1.4 with 100%of conditioned floor area in building served by DOAS. ❑ Exception to air economizer per C403.3 Exception 1,include MECH-ECONO form. 0 Project includes HVAC air distribution systems that provide heating and/or cooling If yes,provide a MECH-FANSYS-SUM form. Fan Power ❑ For one or more systems,the total fan motor nameplate hp of all fans in HVAC system exceeds 5hp. If yes,provide a seperate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold. Refer to Section C403.2.11 and MECH-FANSYS-DOC for requirements and exceptions. HVAC Hydronic Systems ElHydronic chilled water El Water-loopheat pump ElNo hydronic systems ❑ Hydronic heating water ❑ Geothermal ❑ C406.2 More efficient HVAC equipment and fan systems Requires 90%of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9)or air-to-water heat pumps and heat recovery chillers.All equipment listed in tables C403.2.3(1)-(7)must be 15%more efficient than minimum requirements.All stand alone supply,return,and exhaust fans over 1 hp must have FEQ z 71 and must be C406 Additional Efficiency selected within 10%of maximum total or static pressure. ❑ C406.6 Dedicated outdoor air system(DOAS) Options-Mechanical Requires 90%of conditioned floor area to be served by a DOAS per C403.6 that delivers required ventilation air in a manner that does not require space conditioning fan operation. ❑ C406.7 Reduced energy in service water heating Requires 90%of floor area be in occupancy types listed in C406.7.I and that 60%of annual hot water energy use be provided by heat pump,waste heat recovery or solar water-heating systems. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary, • • 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 Equipment Type(s) ❑ Hot water heating tank(s) ❑ Instantaneous ❑ No service water systems Service Water Heating ❑ Dedicated boiler ❑ Heat exchange from space heat boiler or Systems central hot water/steam Distribution Type(s) ❑ Circulation System ❑ On-demand Commissioning Commissioning is required for: ❑ Mechanical systems per C408.2 ❑ Service water heating systems per C408.4 If required,commissioning shall be performed for all applicable systems regardless of individual equipment capacity. Exceptions to commissioning requirements: 0 Total output capacity of all mechanical space conditioning systems in the building do not exceed 240,000 Btu/h cooling or 300,000 Btu/h heating.Mechanical systems commissioning not required. ❑ Capacity of largest service water heating system in building does not exceed 200,000 Btu/h.Service water heating systems commissioning not required. Low Energy and Semi-Heated Spaces (Note 6 and 7) Peak Space Heating Cooling Conditioning Space Area Served, Capacity,Btu/h Capacity,Btu/h Capacity, Compliance Type Location in Plan(s) Space(s)Served square feet (Note 4) (Note 5) Btu/h-sf Check Notes Note 4-Provide total installed heating output capacity of systems serving Low Energy or Semi-Heated space(s)in btuh. Note 5-Provide total installed cooling capacity of system serving Low Energy space(s)in Btu/h.Not allowed for semi-heated spaces.Enter 0 if no cooling. Note 6-Refer to Section C402.1.1 Low Energy Building.Intalled peak space conditioning capacity,heating or cooling,may not exceed 3.4 Btu/h'sf. Note 7-Refer to Section C402.1.1.1 and Semi-Heated Space definition in Chapter 2. Total heating output capacity may not exceed 8 Btu/h*sf. Only systems without electric resistance heating and no cooling are eligible for the wall insulation exception under semi-heated. �1ly o� COMMERCIAL MECHANICAL • PERMIT APPLICATION ��ilvGSp Department of Community& Economic Development City of Arlington• 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF CONSTRUCTION DRAWINGS AND ALL OTHER INFORMATION OUTLINED IN THE MECHANICAL PERMIT SUBMITTAL REQUIREMENTS, IF APPLICABLE. Type of Permit: ❑ New Installation �✓ Replacement ❑ Alteration Project Address: 16410 Smoky Point Blvd Parcel #: 31052900100800 Replacement of NE corner 15 ton RTU Project Description: Valuation:60,000 Owner: Smoky Point Professional group Phone#:425-239-5074 Address: 1505 E. 5th St City: Arlington State:WA Zip:98223 Email Address: dale@me.com dale Duskin Contact Person: Phone #: 425-239-5074 Address: 1505 5th St City:Arlington State: WA Zip: 98223 Email Address:DALE@ME.COM Contractor Name:Evergreen State Heat & AC Phone #: 425-252-3114 Contractor Address: 2120 Pacific Ave City: Everett State:WA Zip: 98201 Email:mark@essmwa.com Contact Person: mark Payne Contractor License Number: EVERGSS0220T Expiration: Nov- 17 Please indicate type of number of appliances: FURNACE CONDENSING UNIT GAS PIPING OUTLET BOILER HEAT PUMP(multi-split) UNIT HEATER CHILLER HEAT PUMP(mini-split) PAINT BOOTH COOLER HEAT PUMP(other) TYPE I HOOD AC(air cooled) HEAT REJECTION EQUIP TYPE II HOOD AC(water cooled) VENTILATION SYSTEM AST AC(evaporator) PACKAGED UNIT UST AC(VRF) DRYER OTHER I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described described property will b rules and regulation of the State of Washington. Applicants Signature:� � Date 04/04/2017 Applicants Printed Name: Mark Payne FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received 6/16LP Page 1 of 1