Loading...
HomeMy WebLinkAbout3506 168TH ST NE_BLD6575_2026 CITY OF ARLINGTON 1820159th A%rnuc NE,Arliilloi,WA 98223 INS1111-1 IONS:3(#11N1.1-3117-1'cmii Ccrdcr:301 W3551 BUILDING PER1111" 3506 168T11 STNF Pcrmit#:6575 PERMIT EXPIRES 180 DAYS AFUR Pan.-cl 31(152" (tl(11200 DATE OF ISS[DANCF Scqv of Wtxk:Comrrt Existing Branch Bank to Retail Jcwci y Store Valuation:640W.00 0 NANER APPLICAN-T CONTRACTOR \\'J LLC Tom Rochon Pioneer Construction Services %I I STATE A\rE S E E 68M Ba-*-%icw Dr.NW 25M 121h r1-.r NW MARYSVILLE,\VA 98270 Tulalip,WA 98271 Stanwood,WA 98292 4253464825 4255827405 11C:PIONEC9905NW EXP:08/19fM AIECIIANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRI[MON PERT\fff TYPE: CO\t\IERCtAL ALTERATION CODE YEAR: 2021 STORIES: I CONST_TYPE: VB DR'II.iL\G UNITS: OCC GROUP: Nl:Mercantile BUILDINGS: OCC LOAD: PIERLIIIT APPROVAL, The issuance or granting of this permit shall not be construed to be a permit for,or approval of;any violation of this Code or any other ardinanoc or order of the City of any slate or federal law,or of any order,proclamation,Dance adhire or dwsion of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The brnldng official is audwnzed to pre%rm occupancy or use of a structure where in violation of the Code,any oilier City ordinances of dis jurisdiction or any oth-r ord�e or z order of the City,or of any stage ar fC A lawn,Cr of any order,prod pMffincie ad%ive os decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the bass of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Grnrmor_ I AGREE TO CONIPLY WITH CITY ARID STATE LAWS REGULATING CONSTRUCTION AND IN DOAG THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HiSoHER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRCl10. SAI,Y_S TAX NOT/C'F.:Sales tax relating to construction and construction materials in the City of Arlington nxist be reported on 5urr sales lax return form and coded City of Adol;lori 143101. —;�7— f IM All" i lure D le Building Official Irate CONDITIONS Will rrquirc Lei s€m and exit ym-, p-way Wtvg.Ashore to apprnrd pE.ins.Pci"and plans shag be onsi:c for inspcctimn.Cal liar inshcclKms. The pnVrcrty onnR shall crmne that the cexnUuctim projccl ccrnilAim%vih at aPplixalk nxtior cocks aryl tepulalions.The propettly owner shill,also ensure that the constructixt 1-nx*cl does not cause any adverse ingrrcl On the surrounding environment or consnTmity.llre lxt)Iktty owner sluill lx:reslxwnsdrle I'M(rl)taita►g all accessary lermits atxl approvals fro►n the;relevant authOritics befow commc-wiig a mmictixt the Irn>,xrty c>,vrx r shall cininic dirt tlx:coicstnx:lrnr project—11plics wits all applicabic dcsip m%-kw rLY}t4rnrcoLs. MIS PIRNi1T,UT1110R17F-S ONI.Y THE Al ORK NOTED.TIIIS PERMIT COVERS WORK TO FIE DONE ON PRIVATE. PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS. MARQUEES 17PC.)A ILL REQUIRE SEPARATE:PERMISSION. PERMIT FEES Datr Ikscription Fee Amount 07f23r2025 Bulking Plan Re%iew 572526 07232325 CredtCardSersnoe S21.76 07=25 Prooessing/Technology $25.00 07232025 Building Permit $1,115.78 07232025 Sate Slydiarge-Commercial M-00 07232025 CtedtCard Sauce S34-97 Total Due: S1,947.77 Total Payment: $1,947.77 Balance Due: S0.00 CALL FOR INSPECTIONS Call]In-330 pm for next day inspection,allow 48 hours for Fur Inspections When calling for an inspection please leave the follovsing information: Peruat 1\®ber,T}pe of Inspection being requested,and whetheryoa prefer morning or afternoon INSPECTIO-N WFOMIATION PassiFai COMMERCIAL TENANT IMPROVEMENT PERMIT APPLICATION Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 The following information is required for Commercial, Multi-Family,and Mixed-Use Building Permit Applications. Mark each box to designate that the information has been provided. Please submit this checklist as part of the submittal documents.See ASSISTANCE BULLETIN#30 for detailed design requirements. EACH BUILDING OR STRUCTURE REQUIRES A SEPARATE SUBMITTAL. SUBMIT ELECTRONIC FILES FOR EACH OF THE FOLLOWING;Incomplete applications will not be accepted. REQUIRED DOCUMENTS ✓ City of Arlington Commercial Tenant Improvement Permit Application ✓ Site Plan ✓ Architectural Plans Structural Plans Structural Calculations Mechanical System Modifications, (if applicable) Plumbing System Modifications, (if applicable) Project Specification Manuals, (if applicable) WSEC Compliance Forms,(if applicable) https:[/waenergycodes.com/ Special Inspection and Testing Agreement Deferred Submittal Request Airport Property Lease (if building is located within the Arlington Airport Property Boundary) 1. Plan Review fee is due at time of submittal and remaining balance will be due at time of issuance. 2. The City of Arlington does not review or inspect electrical systems.Contact Labor and Industries at lni.wa.gov or 360-416-3000. A. DEFERRED SUBMITTALS If the project requires any of the following,a Deferred Submittal Request MUST be completed.Deferred submittals require separate applications,plans and plan review. 1. Mechanical Plans (if not included in the plan set) 2. Plumbing Plans (if not included in the plan set) 3. Fire Sprinkler 4. Fire Alarm 5. Signage B. SPECIAL INSPECTION AND TESTING AGREEMENT A Special Inspection Firm is required to perform special inspections for the following type of work. *The Special Inspection and Testing Agreement MUST be submitted with the Building Application. ❑ Reinforced Concrete ❑ Structural Steel and Welding ❑ Bolting in Concrete ❑ High-Strength Bolting ❑ Pre-stressed Concrete ❑ Spray-Applied Fireproofing ❑ Shotcrete ❑ Smoke-Control Systems ❑ Structural Masonry ❑ Other-Specify: ❑■ I acknowledge that all items designated as submittal requirements must accompany my Tenant Improvement Permit Application to be considered a complete submittal. COMMERCIAL TENANT IMPROVEMENT INSTALLATION,MODIFICATION OR REMOVAL MAY REQUIRE A SEPARATE PERMIT SUBMITAL *CHECKALL THAT APPLY ❑ Automatic fire extinguishing systems ❑ Compressed gas systems ❑ Fire pumps ❑ Flammable and combustible liquids (tanks,piping etc.) ❑ Standpipe systems ❑ Hazardous materials ❑ Private fire hydrants ❑ Industrial ovens/furnace ❑ Fire alarm and detection systems ❑ Spraying or dipping operations ❑ High piled/rack storage ❑ Temporary membrane structure,tents(>200 sq.ft.)or canopies(>400 sq.ft.) ❑ Provide details on any of the above checked items: Type of Permit: New Space ❑ Addition ✓ Alteration Property Address. 3506 168th St. NE Project valuation: $125,000.00 Lot#: 2 Parcel ID No.: 31052800204200 Subdivision: Project Scope of Work: Remove misc. interior non-bearing walls and add new non-bearing interior walls in new locations. Description of New Tenant Business Operations: IBC Construction Type: VB IBC Occupancy Type: B2 Building/Space Square Footage: 3562 s.f. Number of Stories: 1 Square Footage Per Floor: 1st 3562 s.f. 2nd 3rd 4th 5th 6th Primary Contact: ❑■ Owner ❑ Architect ❑ Engineer ❑ Contractor Owner Name: WJ LLC (Wagner Jewelers-Jeff& CaseyWagner) Office No.: 360-653-8200 Email Address: jwagner871@aol.com & kcwagner32@hotmailcom Cell No.: 360-202-7230&425-314-4368 Mailin Address: 9611 State Ave. city:Marysville state:WA zip. 98270 Architect Name: Office No.: Email Address: Cell No.: Mailing Address: City: State: Zip: Professional License Number: Expiration Date: Engineer Name: Office No.: Email Address: Cell No.: Mailing Address: City: State: Zip: Professional License Number: Expiration Date: Primary Contractor: Pioneer Construction Services (PCS) Jim Fagerlie Office No.: 425-582-7405 Email Address: jim@pioneerconstructionservices.com cell No.: 425-508-2852 Mailing Address: 25205 12th Ave. NW City: Stanwood State: WA Zip: 98292 L&I Contractor License Number: PIONECS905NW Expiration Date: 08/19/2026 REV03.2022 Page 2 of 7 COMMERCIAL TENANT IMPROVEMENT MECHANICAL SYSTEM INFORMATION Type of Permit: O New Installation O Addition O Alteration O Replaced O Gas Piping Mechanical Contractor: Office No.: Email Address: Cell No.: Mailing Address: City: State: Zip: L&I Contractor License Number: Expiration Date: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured per IFGS,Section 415 • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of each appliance Gas Piping Specification and complete Schematic PAGE 4 O Not Applicable Proposed Piping Material: O CSST O Brass O Black Steel O Galvanized Steel O Other Proposed Piping Size: 0 1/2" O S/s" 03/4 O 1" O 11/2 O 2" Inlet Pressure: Pressure Drop: Specific Gravity: MECHANICAL PERMIT FEES (per unit) Type of Fixture No.of Units Cost per Unit Subtotal Additional Plan Review fees x $ 75.00 = $ Air Cond.Unit<_100Btu h x $ 15.00 = $ Air Cond.Unit>100Btu h x $ 25.00 = $ Air Cond.Unit>50OBtu/hp x $ 50.00 = $ Air Handling Units x $ 15.00 = $ Base Mechanical Fee $ 25.00 $ 25.00 Boiler<100Btu h>3h x $ 15.00 = $ Boiler>1 million Btu/h<50hp x $ 25.00 = $ Boiler>1.5 million Btu/h<50hp x $ 50.00 = $ Boiler>100Btu/h 3-15hp x $ 15.00 = $ Boiler>500Btu h 15-30hp x $ 25.00 = $ Commercial Hoods-Type I x 1 $ 25.00 = $ Commercial Hoods-Type II x $ 50.00 = $ Diffusers x $ 15.00 = $ Dryer Ducting x $ 15.00 = $ Ductwork(drawings required) x $ 25.00 = $ Evaporative Coolers x $ 15.00 = $ Exhaust Ventilation Fans x $ 15.00 = $ Fireplace/Insert/Stove x $ 15.00 = $ Forced Air Heat<_100 Btu h x $ 15.00 = $ Forced Air Heat>100 Btu/h x $ 25.00 = $ Gas Clothes Dryer x $ 15.00 = $ Gas Fired AC 15100 Btu h x $ 15.00 = $ REV03.2022 Page 3 of 7 COMMERCIAL TENANT IMPROVEMENT MECHANICAL PERMIT FEES (per unit) Gas Fired AC >100 Btu h x $ 25.00 = $ Gas Fired AC > 500 Btu h x $ 50.00 = $ Gas Pi in <_ 5 units x $ 15.00 = $ Gas Piping> 5 units (plus <5 units) x $ 2.00 = $ Heat Exchangers x $ 15.00 = $ Heat Pump-Condensing Unit x $ 25.00 = $ Hot Water Heat Coils x $ 15.00 = $ Miscellaneous Appliance-regulated by x $ 15.00 = $ mechanical code,not otherwise specified Pkg.Units <-100btu x $ 25.00 = $ Pkg.Units >100btu x $ 50.00 = $ Range/Cook top-Gas Fired x $ 15.00 = $ Refrigeration Unit 5100Btu h x $ 15.00 = $ Refrigeration Unit>100Btu/h x $ 25.00 = $ Refrigeration Unit>500Btu/h x $ 50.00 = $ Re-inspection fee all x $ 75.00 = $ Unit Heaters <_ 100 Btu h x $ 15.00 = $ Unit Heaters >100 Btu h x $ 25.00 = $ VAV Boxes (Variable Air Volume,part of air x $ 10.00 = $ conditioning system) Wall Heaters- Gas Fired x $ 25.00 = $ Water Heater- Gas Fired x $ 25.00 = $ Permit Fee $ Table 4-8; Plan Review Fee $ Processing/Technology Fee $25.00 Total $ PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY— USE A SEPARATE SHEET, IF NECESSARY ❑ SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE:Any interior pressure regulators must be indicated REV03.2022 Page 4 of 7 COMMERCIAL TENANT IMPROVEMENT PLUMBING SYSTEM INFORMATION Type of Permit: O New Installation O Addition O Alteration O Replaced O Industrial Plumbing Contractor: Office No.: Email Address: Cell No.: Mailing Address: City: State: Zip: L&I Contractor License Number: Expiration Date: The following items need to be specified on the plans: O Fixture specifications and equipment with locations. O Location and type of all backflow assemblies for each fixture. O Calculations for Grease Interceptor. O Pipe size and location of sanitary and potable water systems. O Riser diagram of waste,vent,and rain water systems,including sizes. O Medical gas piping riser diagram,type of gas, storage room and size of piping. PLUMBING PERMIT FEES (per fixture) Commercial plumbing permits are required to submit line drawings.A plan review fee of 65%per Table 4-6 for plumbing permits will be assessed at time of submittal. Includes two (2) inspections with permit. Tvve of Fixture No. of Fixtures Cost per Fixture Subtotal Additional Plan Review fees x $ 75.00 = Alteration/repair piping x $ 15.00 = Backflow Assembly x $25.00 = Base Plumbing Fee $ 25.00 $25.00 Bath/Shower Combo x $ 15.00 = Building Main Waste x $ 25.00 = Clothes Washer 1 x $ 15.00 = $15.00 Dishwasher 1 x $ 15.00 = $15.00 Drinking Fountain x $ 15.00 = Floor Drains x $ 15.00 = REV03.2022 Page 5 of 7 COMMERCIAL TENANT IMPROVEMENT PLUMBING PERMIT FEES (per fixture) Grease Interceptor x $ 75.00 = Grease Trap x $ 25.00 = Hose Bibb x $ 15.00 = Icemaker Refri erator x $ 15.00 = Irrigation-per meter x $ 25.00 = Kitchen Sink&Disposal 1 x $ 15.00 = $15.00 Laundry Tray x $ 15.00 = Lavatory x $ 15.00 = Med Gas Pi in <- 5 inlets outlets x $ 60.00 = Med Gas Piping> 5 inlets/outlets (plus :5 5 x $ 5.00 = inlets outlets Miscellaneous -regulated by plumbing x $ 15.00 = code,not otherwise specified Pretreatment Interceptor x $ 15.00 = Re-inspection Fee all x $ 75.00 = Roof Drains x $ 15.00 = Shower (only) 1 x $ 15.00 = $15.00 Sink bar,service,etc. 2 IXE $ 15.00 = $30.00 Toilets $ 15.00 = Urinal $ 15.00 = Vacuum Breakers $ 25.00 = Water Heater x $ 25.00 = Water Heater-Tankless x $ 25.00 = Permit Fee $90.00 Table 4-6; Plan Review Fee Processing/Technology Fee $25.00 Total PROPOSED BUILDING USE ❑ New ❑ Addition/Alteration ❑ Medical ❑ Automotive Based ❑ Industrial ❑ Office ❑ Restaurant ❑ Machine Shop 0 Other: Retail Jewelry Store CROSS CONNECTION Please check all appliances that are proposed or permanently connected to the water supply. ❑ Ice Machine ❑ Dialysis Equip. ❑ Air washers ❑ Coffee Urn/Espresso ❑ Hydrotherapy Equip. ❑ Steam Generators ❑ Carbonated Bev. ❑ Dental Equip. ❑ Dye Vats ❑ Fume Hoods ❑ Laboratory Equip. ❑ Pressure Washers ❑ Degreasers ❑ Autoclave/Sterilizers ❑ Cooling Towers ❑ Hot Tub/Spa ❑ Decorative Fountain ❑ Fire Sprinkler ❑ Aquarium ❑ Swimming Pools ❑ Sprinkler w/chemicals ❑ Lawn Irrigation ❑ Well on property ❑ Other: WASTEWATER DISCHARGE Does the plumbing system currently have a grease interceptor? ❑ Yes ❑ No ❑ Don't Know Does the plumbing system currently have an oil/water ❑ Yes ❑ No ❑ Don't Know separator? REV03.2022 Page 6 of 7 COMMERCIAL TENANT IMPROVEMENT Is water used in the business process (washing,rinsing, ❑ Yes 0 No ❑ Don't Know cooling)? Does your business require a NPDES permit? ❑ Yes 0 No ❑ Don't Know I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington. _1_1K9_M1a'd1 Thomas Ro c h o n 06/22/2025 Signature Print Name Date REV03.2022 Page 7 of 7 REVISIONS: Wagner Jewelers T . I . 3. 4. 5. 3506 168th St. NE Arlington, Washington 98223 PARCEL NO. 31052800204200 ABBREVIATIONS VICINITY MAP PROJECT PARTICIPANTS PROJECT DATA DRAWING INDEX OWNER: WJ,LLC-Contact Jeff Wagner&Casey Wagner JURISDICTION. City of Arlington A0.1 Cover Sheet & AND (E) EXISTING L LENGTH SCD SEE CIVIL DRAWINGS 9611 State Ave.Ste E,Marysville,WA PROJECT ADDRESS 3506 168th St.NE A1.1 Existing Floor Plan/Demo Plan ANGLE EA EACH LAV LAVATORY SCH SCHEDULE Cell No.:360-202-7230 Arlington,WA.,98223 A2.1 Main Floor Plan @ AT ECB EROSION CONTROL BARRIER LF LINEAL FOOT SD SMOKE DETECTOR Email:jwagner871@aol.com 0 DIAMETER ELEC ELECTRICAL LPG LIQUID PROPANE GAS SECT SECTION kcwagner32@hotmail.com PARCEL NO. _ _ 31052800204200 DEGREE ENG ENGINEER(ING) LVL LAMINATED VENEER LUMBER SED SEE ELECTRICAL DRAWINGS CONTRACTOR: PCs Pioneer Construclion Services,Jim Fagerlie CODE 2021 IBC WITH WASHINGTON # POUND OR NUMBER EQ EQUAL MAX MAXIMUM SF SQUARE FEET AMENDMENTS SQUARE FOOT EXT EXTERIOR MB MACHINE BOLT SH SINGLE HUNG 0""°"""°"""°'°""" ""°"'"` Contractor License No.PIONECS905NW AS ANCHOR BOLT FAU FORCED AIR UNIT MECH MECHANICAL SHT SHEET I ,M;"„",YP 0 Cell No.:425-508-2852 ABV ABOVE FD FLOOR DRAIN MFR MANUFACTURER SIM SIMILAR �O,aaaPo�",. Email:jim@pioneerconstructionservices.com ZONING. CC Commercial Corridor ACOUS ACOUSTIC FIE FIRE EXTINGUISHER MIN MINIMUM SL SLIDER DESIGNER: Tom Rochon LEGAL DESCRIPTION. .SEC 28 TWP 31 RGE 05 LOT 2 OF BSP REC AF ACT ACOUSTIC CEILING TILE FF FINISH FLOOR MISC MISCELLANEOUS SMD SEE MECHANICAL DRAWINGS a, „, o m 6804 Bayview Dr.NW 8804065010 AS AMD PER AF9502105002& AFF ABOVE FINISH FLOOR FG FULL GLASS MOD MODULAR SMS SHEET METAL SCREW _" " Tulalip,WA 98271 FURTHER AMD PER AF9507105005 TGW N 35FT ALUM ALUMINUM FHWS FLAT HEAD WOOD SCREW MTD MOUNTED SPD SEE PLUMBING DRAWINGS 0::4:, 1: '°^"9 o y m:p Cell No.:425-346-4825 s. '"' OF LOT 3 SD BSP BEING A PTN OF NW1/4 LESS ARCH ARCHITECTURAL FIN FINISH MTL METAL SPEC SPECIFICATIONS t Email:thomashrochon@gmail.com AWN AWNING FUR FLOOR MUL MULLED WINDOW SS STAINLESS STEEL :" ADDL IERd PER SWD REC 5180558 PER & BD BOARD FOC FACE OF CONCRETE/COLUMN (N) NEW STD STANDARD a"'""' F"m°L1Pb1LP5➢ © PROJECT SITE: AM DRIER SWD REC 2-BLA 1 REC PER CITY 03 BIF BIFOLD FOF FACE OF FRAMING/FINISH NG NATURAL GAS STK SELECT TIGHT KNOT .•mm.,"= °« 3506168th St.NE ARL BLA MN-99-0142-BLA REC AF799912035003 e h="wm.,m°per="� ° Arlington,WA 98223 BLDG BLKG BUILDING BLOCKING FOIC FURNISHED BY OWNER,INSTALLED NIC NOT IN CONTRACT STL STEEL .,".,C O,`a"^„.'" BLW BELOW BY CONTRACTOR NOM NOMINAL STRUC STRUCTURAL "g e m CONSTRUCTION TYPE TYPE VN BM BEAM FOS FACE OF STRUCTURE/STUD/STEEL NTS NOT TO SCALE STS SELF TAPPING SCREW ""W""`� -� SET BACKS. Front Yard ExI ng BTM BOTTOM FT FOOT OR FEET OC ON CENTER SV SHEET VINYL + m•°s,==_"�_ Side Yard Existing BUR BUILT-UP ROOFING FTG FOOTING OD OUTSIDE DIAMETER (T) TEMPERED •"�=o °"" L c CENTERLINE FX FIXED GLASS OPH OPPOSITE HAND T&G TONGUE&GROOVE °•°" sg`a Rear Yard Existing r CLG CEILING GA GAUGE OSB ORIENTED STRAND BOARD TBD TO BE DETERMINED MAXIMUM Existing CUR CLEAR GALV GALVANIZED PH PANIC HARDWARE TOC TOP OF CONCRETE BUILDING HEIGHT /A CMU CONCRETE MASONRY UNIT GLB GLULAM BEAM p PLATE Top TOP OF PLATE _ °� "�`" " BUILDING & LOT SIZE w 04 COL COLUMN GSM GALVANIZED SHEET METAL PLAM PLASTIC LAMINATE TOF TOP OF FLOOR L COMP COMPOSITE GWB GYPSUM WALLBOARD PLWD PLYWOOD TOS TOP OF SLAB/STEEL a City of Arlington cV CONC CONCRETE GYP GYPSUM PR PAIR TOW TOP OF WALL Z 00 CONT CONTINUOUS HC HOLLOW CORE PSF POUNDS PER SQUARE FOOT TS TUBE STEEL EXISTING Building Department G) CS CASEMENT HDR HEADER PT PRESSURE(PRESERVATIVE) TYR TYPICAL STRUCTURE to t' CPT CARPET HHS HEX HEAD SCREW TREATED UNO UNLESS NOTED OTHERWISE REMAIN. Existing Floor Area:3562 s.f. APPROVED Q DBL DOUBLE HM HOLLOW METAL REINF REINFORCING VERT VERTICAL DEMO DEMOLISH HORIZ HORIZONTAL RET RETAINING VIF VERIFY IN FIELD LOT SIZE AREA. . . 55,846 s.f.or.78 acre(s) Kevin Olander- 06/26/2025 �\ -' DE T DETAIL HVAC HEATINGNENTILATION/ RHWS ROUND HEAD WOOD SCREW VPF VEGETATION PROTECTION FENCE W 0 DH DOUBLE HUNG AIRCONDITIONING RM ROOM VTO VENT ATOUTSIDE No changes authorized unless approved b �•/ DIM DIMENSION ID INSIDE DIAMETER RO ROUGH OPENING W WIDTH 9 PP Y O DWG DRAWING INSUL INSULATION RWL RAIN WATERLEADER W WITH the Building Official cc INT INTERIOR SC SOLID CORE WD WOOD L O WT WEIGHT M i SYMBOLS SITE PLAN a 168th St. NE 174.70' DRAWING NUMBER �� v' •- ' REVISION REFERENCE /^, REVISION NUMBER •;fe°1 Plardigg•• -,'_ :•.{g)plzrN.g --.•• n BUILDING SECTION X i-• '-�• -• ' •' - V OR WALL SECTION A4.1 SHEET NUMBER !- Exist. -- . Property REFERENCE MASONRY 0 - Monument - Pf0 ert Owner n ;' Exist.Light W Sign '-{gl�ar�Em9 ;•:- WJ LLC 7 TYp(6) CONCRETE •itjPlanting: 0 Places •:'•' Site Address DRAWING NUMBER STRUCTURAL p II REFERENCE 'I --:. Existing Concrete ••- '- '••J 3506166th St.NE, EXTERIOR ELEVATION X GRIDS T INSULATION(LOOSE OR BATT) -feJ Plantmg• S dewalk -.;-•.::•. Actin ton,WA 98223 REFERENCE A3.1 — (*Pl?-ng- Parcel No. NOTE: INSULATION(RIGID) ��.e 32'0" SHEET NUMBER ,_ ':'•; 31052800204200 GRID LINES LOCATE FACE OF $ 1 DRAWING NUMBER FRAMING AND/OR ;;; 320 170" 25'-0" FOUNDATION STEM WALLS EARTH 8sb° 8'fi" 25'-0" 18'-6" k1' 1Y2%1L m I 42'-6" CCCO�ercial Corridor INTERIOR ELEVATION UNO 4 A5.1 2 TRUE NORTH - - REFERENCE SHEET NUMBER SAND I PLASTER/MORTAR I { o I- Legal Description 3 - �E­11,1.n' q Existing .-� -O Sign 0 N I SEC 28 TWP 31 RGE 05 LOT 2 OF BSP REC AF NORTH ARROW Buildin DRAWING NUMBER NORTH � { ,.,I 8804065010 AS AMD PER AF9502105002& ROCK FILL Footprint 3562 s.f. �' I FURTHER AMD PER AF9507105005 TGW N 35FT DETAIL REFERENCE m ® =o ' OF LOT 3 SD BSP BEING A PTN 32 1114 LESS AX.1 SHEET NUMBER ® METAL(LARGE SCALE) � 4 � � � t,� ADDL R/W PER SWD REC AF9303220594 8 AMD UP 7R •p 4 '�16-a' O1I ••'g, PER SWD REC AF9305180558 PER CITY OF ARL STAIRDIRECTION, ___ __ ___ #RISERS&TREADS 11T GYPSUM WALLBOARD r — — ,- BLA MN-99-0142-BLA REC AF799912035003 ROOM NAME&NUMBER ROOM FINISHED WOOD O 79-3• (e)Planting Lot Size ROOM NUMBER ® Y DOOR REFERENCE 001 O O .78 Acre or 33,977 s.f. 101X DOOR LETTER STRUCTURALWOOD E - � •••-� Existing Building Area (CONTINUOUS MEMBER) (n LLI EQUIPMENT NUMBER 101 0 ,•I 3562 s.f. '1' WINDOW REFERENCE <X}�WINDOW TYPE STRUCTURAL WOOD W CENTER LINES,FLOOR LINES _ (NON-CONTINUOUS MEMBER) Exist Existing Landscape Area AT EXTERIOR ELEVATIONS, `-4 Dumpstar 9994 J. '(//�� PROJECTED LINES ® PLYWOOD Enclosure `" WALL TYPE �x WALL TYPE - _ Existing Parking Driveway Area � PROPERTY LINES,BOUNDARY '• '- ' '•: Typ. •'• '• 18,824 s.f. '1' LINES ® TILE(CERAMIC) - - •:' ' LJJ I•' Existing Parking Stalls Provided � KEY NOTE REFERENCE '7t�REFERENCE NUMBER ';.fey'plantlng,'• _ v HIDDEN LINES ------------ 18 •,'d9)Pld!tti�q-:•1 1 ADA Parking Stall O '..I 29 Standard Parking Stalls � U CASEWORK REFERENCE 101 SCHEDULE NUMBER BREAK LINES A 30 Total Existing Parking Stalls Legend _/ DATE:06.20.24 5 DE SIGNED:TR - Existing Asphalt(18,824 s.f.) DRAWN:TR True Existing North Existing Concrete Sidewalks(993 s.f.) SHEET: �� SITE PLAN 0:! 1_� 0 Existing Landscape(9994 s.f.) L \ II' / Date:06.20.25 a A 0 . 1 1 III/ Scale: 1"=20'-0" REVISIONS: 1. 2. 3. 4. 5. - - - - - - - - - - - - I I I I I I I I I I I I I I I I I I I I 6'-6" 4._1„ R.O. ❑ ❑ Drive-up Window I Storage Room ` Tellers \ jVault J 71 z, I I I I I I II I V I II I II I I II I I I I �/� I I I I II I II I II I II I I II I I I IL N L--- L----'I L--- ----J �---J ---J W N=J _� ZtbJanitor J— JL--- e L—J r— - r— � r— -- r— — r— _Y Y_J U W. M• Closet I �____� �____� �____� `_____� L L J Q Ilm� m� IIr----------------------------------� q II II M w c IIII II O _jLi, Fire L Extinguisher S Hall (FE) W M Q V/ 3'0"x TO" I—— Lobby Lounge/ Kitchen 3'o"xTo" 4 -- F---a' Fire ❑ F \ Extinguisher (F.EJ r — L— — J L fi — J _J Elect — Panel L——J II Office p Supplies tt I I � h�t �ti 06 L -- a O Demolition L LL 00 FLOOR PLAN 0 2' 4' 6' a, Wall Types Scale:1/4"=1'-0" U) North Existing Wall to Remain X Existing Wall to be Removed 4-0W Existing Window to be Removed City of Arlington /� -1 _ Existing Door to be Removed Building Department DATE:06.20.24 �\ APPROVED DESIGNED:TR Kevin Olander- 06/26/2025 DRAWN:TR No changes authorized unless approved by SHEET the Building Official L a A1 . 1 REVISIONS: 1. 2. 3. 4. 5. I I I I I I I I I I I I I I I I g•_0" I N w (2)2' x4'0" Picture Window Watch Night Workbench Deposit -------------- Eating Countertop Security Fire ( Server Extinguisher (F.E.) Teller Wagner Jewelers wave New ry 4 Check-out Sign Kitchen o+` Jewelers _ _ J Water "' V Dispensor Stackabl Coals —— -- 22"z 22„— — 22"x 22„ — ®——— — — V a u It 3'0"x TO" ■ L S k dw I 43 Washer/ I I I I Take-In 1'-4" 2'-„" 1-6" Dryer ITIf Tl if TI IT IT 2-6- 6--6" 2'-10 3'0"x TO" New 3'_0" '_0" 12'-0" -r' t,a-6" 32 L W Cq OO q p• 2-Eq.Spaces tq 33 O00 W. M. z a) rn No Changes No Changes —————————————————————T-————————— U) Q ..+ 0 2�6,�x T0" 4titi 34 s O�Q00 30'x7.0" Closet 19 18 1 241 0 ®�13 1 Sitting Fire 2'6"x 7'0" L C S Extinguisher Area u'> (F.E.) w 23 Island 14 M Q I I 4-8 O52 52 52 52 si nelers 21 16 3'°^x T°" g 1 12 w 2: II I I � 4•-4^ 4s 35 22•• 3O• O. ----K-iosk 7 Goldsmith © -------------J -D-1-5 ------------ Q26 3 '0"x7.0" Jewelers Stations , ----------------- - -19 7.1„ Fire Extinguisher Sink (F.E.) 9 6-10" I L Elect. Panel 2: ® 30 O5 © O7 ® q Elect. 58 2 0 Panel Polishing 3'0"x T0" UtiNew Jeffs lity Office Room Sink s7 59 Case 's hwt Y Office 37 —i 37 x T0" J Proposed - O aD FLOOR PLAN 0 1' 2' 4' O WILL all Types Scale:1/4"=1'-0" C North Existing Wall to Remain City of Arlington CM New Wall Construction }+ C 2x4@16"o.c.w/5/6"GWe,Type Building Department w/Sound Insulation APPROVED Kevin Olander-06/26/2025 DATE:06.20.24 DESIGNED:TR No changes authorized unless approved by ■� DRAWN:TR the Building Official t SHEET i a A2 . 1 168th St. NE o _ 174.70' coo (e)Plantin {e)Planting" �. Exist. Q Property Owner 0 Monument '(e)'Planting 1 WJ LLC Exist. Light Sign - . Typ. (6) Site Address �e) P1aritirrg.' 0 Places 4 3506 168th St. NE, Existing Concrete - y � Arlington,WA 98223 Y y' (e� Planting Sidewalk y (0�Ptantmg Parcel No. 32'0" — 31052800204200 El —— — 32'0" 17'0' - 25'-0" J4-0"y Zoning 8'r0" 8'-6" 25'-0" 0 18'-6" 1�4' .1y/2' - 42'-6" CC=Commercial Corridor 0 ol Legal Description Exist. Pylon O q Existing Sign c� �y SEC 28 TWP 31 RGE 05 LOT 2 OF BSP REC AF Building 8804065010 AS AMD PER AF9502105002 & m o Footprint 3562 s.f. �r FURTHER AMD PER AF9507105005 TGW N 35FT O q � OF LOT 3 SD BSP BEING A PTN OF NW1/4 LESS I ADDL R/W PER SWD REC AF9303220594&AMD HH a- PER SWD REC AF9305180558 PER CITY OF ARL — — Z BLA MN-99-0142- BLA REC AF199912035003 7' o (e)Planting LO Lot Size � 79-3 (e) Planting ❑O ❑ _ II .78 Acre or 33,977 s.f. ' J E o Existing Building Area cn Iy1 3562 s.f. Exist. Existing Landscape Area o => Dumpster 9994 s.f. (.0 N _ b Enclosure �y00 9'-0" Existing Parking Driveway Area Typ. 18,824 s.f. yyy' yy.yyyy.yyy .yyy y (e)Plantingy' 18 �e�yp; , ;,;�y Existing Parking Stalls Provided °' 1 ADA Parking Stall y) 29 Standard Parking Stalls 30 Total Existing Parking Stalls (e)Plntirig , Legend -2411-.50y y ® Existing Asphalt(18,824 s.f.) True Existing North Existing Concrete Sidewalks(993 s.f.) S ITE PLAN ° 5' 10' 20' 0 Existing Landscape(9994 s.f.) Date: 06.20.25 Scale: 1" = 20'-0" i CITY OF ARLINGTON CERTIFICATE OF OCCUPANCY INTERNATIONAL BUILDING CODE SECTION 111 NOTE: THIS CERTIFICATE DOES NOT CERTIFY ELECTRICAL WORK At 3506168th St NE Building Permit Number BLD 6575 Name &Address of Owner Occupancy Load Number of Stories WJ LLC 42 1 9611 STATE AVE STE E Type of Construction/ Sprinkler System Required Use MARYSVILLE,WA 98270 VB/No Retail / Office THE Structure HAS BEEN INSPECTED AND APPROVED AS COMPLYING WITH THE 2021 EDITION OF THE INTERNATIONAL BUILDING CODE FOR GROUP M OCCUPANCY ISSUED January 14, 2026 BY BUILDING OFFICIAL Permit#: 6575 Permit Date: 06/24/25 Permit Type: COMMERCIAL ALTERATION Project Name: Wagner Jewelers Tenant Improvement Applicant Name: Tom Rochon Applicant Address: 6804 Bayview Dr. NW Applicant, City, State, Zip: Tulalip,WA 98271 Contact: Tom Rochon Phone: 4253464825 Email: thomashrochon@gmail.com Scope of Work: Convert Existing Branch Bank to Retail Jewelry Store Valuation: 64000.00 Square Feet: 3562 Number of Stories: 1 Construction Type: VB Occupancy Group: M; Mercantile ID Code: Permit Issued: 07/24/2025 Permit Expires: 03/06/2026 Form Permit Type: COMMERCIAL ALTERATION Status: COMPLETE Assigned To: Hannah Hardwick Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 569 Other Retail 31052800204200 3506 168TH ST NE WJ LLC Trade-Apparel& Accessories NEC Contractors Contractor Primary Contact Phone Address Contractor Type License License# Pioneer Construction 4255827405 25205 12th Ave CONSTRUCTION UBI 602 067 915 Services NW CONTRACTOR Pioneer Construction 4255827405 25205 12th Ave CONSTRUCTION Construction PIONECS905NW Services NW CONTRACTOR Contractor Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status O1/05/2026 C20.BUILDING O1/06/2026 01/06/2026 BUILDING Approved FINAL 10/06/2025 C13.CEILINDG 10/07/2025 10/07/2025 BUILDING Approved 09/23/2025 C13.CEILINNGG 09/24/2025 09/24/2025 BUILDING Approved GRID 08/06/2025 C0T WALLBOARD 08/07/2025 08/07/2025 BUILDING Approved 07/29/2025 C09.FRAMING 07/30/2025 07/30/2025 BUILDING Approved Plan Reviews Date Review Type Description Assigned To Review Status COMMERCIAL Approved with 06/24/2025 ALTERATION Will require Exit signs and exit passageway lighting. BUILDING Conditions 06/24/2025 COMMERCIAL No civil comments Development Approved ALTERATION Services Manager 06/24/2025 COMMERCIAL Land use has no concerns. PLANNING Approved ALTERATION Fees Fee Description Notes Amount Building Plan Review Table 4-2 $725.26 Credit Card Service $21.76 Processing/Technology $25.00 Building Permit Table 4-1 $1,115.78 State Surcharge-Commercial Commercial Only $25.00 Credit Card Service $34.97 Total $1,947.77 Attached Letters Date Letter Description 07/22/2025 Building Permit 06/24/2025 Web Form-Building Application Payments Date Paid By Description Payment Type Accepted By Amount 06/24/2025 Thomas Rochon 235145168 Hannah Hardwick $21.76 06/24/2025 XBP Con£ $725.26 235145168 07/22/2025 Tom Rochon 237893808 Hannah Hardwick $34.97 07/22/2025 XBP Conf: $1,165.78 237893808 Outstanding Balance $0.00 Uploaded Files Date File Name 07/24/2025 27485974-20250624 BLD6575 Approved Plans.pdf 07/24/2025 27485971-2025 BLD6575 Issued Permit.pdf 06/24/2025 6affc298c34d247c92e703199c770bdd wagner updated-commercial-tenant-improvement-application.pdf 06/24/2025 b4e895487fd8e32797e275268ac9f5c9 wagner jeweler site plan 062025.pdf 06/24/2025 05dcb107b7dc68baa63fbOdc0e09bdf7 wagner Jeweler t.i. permit set combined 062025.pdf CITY OF ARLINGTON CERTIFICATE OF OCCUPANCY INTERNATIONAL BUILDING CODE SECTION 111 NOTE: THIS CERTIFICATE DOES NOT CERTIFY ELECTRICAL WORK At 3506 1681h St NE Building Permit Number BLD 6575 Name &Address of Owner Occupancy Load Number of Stories WJ LLC 42 1 9611 STATE AVE STE E Type of Construction/ Sprinkler System Required Use MARYSVILLE,WA 98270 VB/No Retail / Office THE Structure HAS BEEN INSPECTED AND APPROVED AS COMPLYING WITH THE 2021 EDITION OF THE INTERNATIONAL BUILDING CODE FOR GROUP M OCCUPANCY ISSUED January 14, 2026 BY BUILDING OFFICIAL