Loading...
HomeMy WebLinkAbout328 S Stillaquamish Ave_BLD886_2026 BUILDING INSPECTION REPORT — MECHANICAL (COMMERCIAL) Permit No. 886 Address: 328 S. Stillaquamish Contractor: Evergreen State Heat and A/C Owner: Arlington Rehab Partners LLC Date: 3/1/2016 ® APPROVAL ❑ PARTIAL APPROVAL ❑ CORRECTION ❑ OTHER APPLIANCE: Split heat pump ECONOMIZER: © DRIP LEG: ❑ HEAT PUMP/AC UNIT: ® SHUTOFF VALVE: ❑ DISCONNECT: ® GAS PIPING: ❑ SEISMIC: ® BRACING: ❑ 3" PAD: ❑ DUCT DETECTOR: ❑ INSULATION/PROTECTION: M SUPERVISION: ❑ L&I Req'd: Yes Date: 3/1/2016 Inspector: Kevin Olander CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:328 S.Stillaquamish Permit#:886 Parcel#:2870048 Valuation: 14000.00 OWNER APPLICANT CONTRACTOR Name:Arlington Rehab Partners LLC Name:Evergreen State Heat and A/C Name:Evergreen State Heat and A/C Address:5962 La Place Ct Ste 170 Address:2120 Pacific Ave Address:2120 Pacific Ave City,State Zip:Carlsbad,CA 92008 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:360-474-8686 Phone:425-252-3114 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Evergreen State Heat and A/C Name: Address:2120 Pacific Ave Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-252-3114 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Mechanical CODE YEAR: 2012 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI10/IRC110. SALES TA "ICE:Sales tax relating to construction and c( struci ion materials in the City of Arlington must be reported on your sales tax return form an ed ity of 1.igton#3101. Kom Signature Print Name Date Released By Da(e CONDITIONS Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 1/22/2016 Mechanical Fee(Enter Fixture Fee) $25.00 1/22/2016 Mechanical Permit Base Fee $25.00 1/22/2016 Mechanical Plan Review Fee $250.00 Total Due: $300.00 Total Payment: $0.00 Balance Due: S300.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon r �� hV/'1A F tr- 2 5. coo KaAr riatdm� Fm- 05 . 00 -Z 50. 00 Soo , 00 Permit Information Date 1/20/2016 Permit Number 886 Project Name PRJ LLC Applicant Name Evergreen State Heat and A/C Applicant Address 2120 Pacific Ave City,State,Zip Everett,WA 98201 Contact Paula Johnson Phone 360-474-8686 Email mark@essmwa.com Permit Type Commercial Mechanical Site Address 328 S.Stillaquamish Valuation 14000.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 1 Proposed Use Remove/replace split heat pump Using SNOPUD rebate for hight efficiency replacement Assigned To Property Information Owner Information Parcel#:2870048 Arlington Rehab Partners LLC Arlington Rehab Partners LLC 5962 La Place Ct Ste 170 328 S Stillaquamish Ave Carlsbad,CA 92008 Contractors Contractor Name Primary Phone Email Contractor Type License License# Contact Evergreen State Heat 425-252- MECHANICAL Labor and and A/C Mark Payne 3114 mark@essmwa.com,CONTRACTOR Industries EVERGSS022OT Review Date Type Description I Target Date I Completed Date I Assigned To T Status 1/20/2016 lCommercial Mechanical 1/27/2016 1 JiKevin Olander 111n Review Uploaded Files Upload File i Date File 1/20/2016 2:17:15 PM IBLD 886 Application pdf }( COMMERCIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington •18204 59th Ave NE •Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF CONSTRUCTION DRAWINGS AND ALL OTHER INFORMATION OUTLINED IN THE MECHANICAL PERMIT SUBMITTAL REQUIREMENTS, IFAPPLICABLE. Type of Permit: New Installation ❑✓ Replacement ❑ Alteration Project Address: 328 S. Stillaguamish, Arlington, WA Parcel#: Remove and replace split heat pump. Using SNOPUD Project Descripti on:rebate for high efficiency replacement Valuation:14,000 Owner:PRJ LLC Phone#: 360-474-8686 Address: 323 2nd St. City: Snohomish State: WA Zip: 98290 Email Address: cleopatraJ49@hotmail.com Paula Johnson Contact Person: Phone#: 360-474-8686 Address:323 2nd St. City:Snohomish State: WA Zip: 98290 Email Address:cleopatra_j499hotmail.com Contractor Name:Evergreen State Heat &A/C Phone#:425-252-3114 Contractor Address:2120 Pacific Ave City:Everett State:WA Zip: 98201 Email:mark@essmwa.com Contractor License Number: nov'16 Expiration: Please indicate type of number of appliances: FURNACE CONDENSING UNIT GAS PIPING OUTLET BOILER HEAT PUMP (multi-split) 1 UNIT HEATER CHILLER HEAT PUMP(mini split) PAINT BOOTH COOLER HEAT PUMP(other) TYPE I HOOD AC(air cooled) HEAT REJECTION EQUIP TYPE II HOOD AC(water cooled) VENTILATION SYSTEM AST AC(evaporator) PACKAGED UNIT UST AC (VRF) DRYER OTHER I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in accordance with the laws,rules and regulation of the State of Washington. Applicants Signature (�1��� �' ,`'��ni/«r' Date 01/20/2016 Applicants Printed Name Mark Payne FOR STAFF USE ONLY Received Permit# Accepted By Amount Received Receipt# Date Re¢AJ4d20 2016 i rAWE"' 4TWR7060-SUB-1 TAG: : A 5 Ton Split System Heat Pump — 1 Ph NOTE:All dimensions are in mm/inches. 4TWR7060A o - Product Specifications OUTDOOR UNIT O® 4TWR706OA1000A POWER CONNS.—V/PH/HZO 208/230/1/60 MIN.BIRCH.CIR.AMPACITY 41 BR.CIR.PROT RTG.-MAX.(AMPS) 60 SERVICE vANI COMPRESSOR CLIMATUFF®-SCROLL — I NO.USED-NO.STAGES 1 -2 ELECTRICAL AND REFRIGERANT VOLTS/PH/HZ 208/230/1/60 COMPONENT CLEARANCES PER PREVAILING CODES, R.L.AMPS O-L.R.AMPS 28.8-152.9 FACTORY INSTALLED START COMPONENTS O NO INSULATION/SOUND BLANKET NO TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1574 15 FEET) COMPRESSOR HEAT YES- - ABOVE UNIT-UNIT SHOULD BE PLACED 50 ROOFRUN-OFF WATER DOES NOT POUR OUTDOOR FAN PROPELLER BIRECTLY ON UNIT,AND SHOULD BE AT LEAST BOS 112'1 FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO$IDES UNRESTRICTED DIA.(IN.)-NO.USED 27.6-1 r- — — — — — --- — — — — — _ TYPE DRIVE-NO.SPEEDS DIRECT-1 CFM @ 0.0 IN.W.G.O 4760 NO.MOTORS-HP 1 -1/4 ELECTRICAL$ERVICI MOTOR SPEED R.P.M. 825 PAN(L VOLTS/PH/HZ 208/230/1/60 R F.L.AMPS 1.30 OUTDOOR COIL—TYPE SPINE FIN TM FlG. 1 ROWS-F.P.I. 2-24 25 111 _ FACE AREA(SQ.FT.) 29.15 A TUBE SIZE(IN.) 3/8 REFRIGERANT CONTROL EEV 7b`T(7/B[DIA Nu( REFRIGERANT R-410A Law 1,11.111E LBS.—R-410A(O.D.UNIT)© 13 LBS.-3 OZ. • 79 6 f IIYI DIA FACTORY SUPPLIED YES ROLE114 CONIiaWIT"i D LINE SIZE-IN.O.D.GAS© 1-1/8 BON BOTTOM FOR ELECTRICAL H POWER SUPRLY F LINE SIZE-IN.O.D.LIQ.© 3/8 CHARGING SPECIFICATION -N 0 FOR ALTERNA TEELECTRICAI ROUTING — J AS 1IW[ 1/4 IVNA DAll SERVICE VALVE, 'D' SUBCOOLING 10°F L IOUID l n[1[RN IC,VAIY(, 1 D ILwAI(eNA1[D CONW(CIION WITH 114'SAE H X W X D A G FURt IXn SYW( uP MEIBS. DIMENSIONS riAM,ni`rPA°ssuei"I:P I If CRATED(IN.) 51.0 X 35.1 X 38.7 WEIGHT - SHIPPING(LBS.) 330 NET(LBS.) 293 N k U10 LINE SERVICE YC. 'E' I.D. FEMALE IID CONNECTIONH I4'SAEFLARE OI Certified in accordance WILL theAirSourceUnilaryA7-condilionerEquipmentcerlificationprogram,whichisbased SSURE TAP FITTINGonARIstandard210/240 In order to achieveARlstandardrating,theindoorfantimedelayonthecomfortcontrol AS UYtSFAVI[CAIY[. must be enabled. L [ DR![DYY(CIIDY vI1N 1/4'SA( FLARE ® Rated in accordance VAIN ARI standard 270. G PYLSSYAN EAP TITHING. O CaIGABIed in a7otederlOe With NaM-Elec.Codes.Use Orly'HACR Orcuil breakers Or fuses. O StandardAXr—Dry Cod—01Adoar FlG. 2 From Dwg.D152635 (D This vague apprmamale.For wewecisevaluesee unit nameptale. ©Max.tnea Eenglh 6o D:Max,LD-SuQi00 25 It.:Max lift•Lq A 25 f.Far greater length consult refrigerant piping software Pub.No.323312-0'1'denoles latest revision). MODELS BASE A B C D E F G H J K O This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute 4TWR7060A q 1147 a46 B70 1.1/8 3/e 152 B BB 21s BB 730 minimum branch pm Ris uil ampacity and max. e m.The vaue shown is the branch circuit selection current. (45.1/B) (37-1/4) (34-1/4) () (3-7/B) (B-5/B) (3-3/8 ) (28-3/4) O Nameansno start componenls.Yes means quckslAr[MtcoxonerrsPTCmeans positive lav temperalurecoeflicienl enter. Sound Power Level A-Weighted Sound Full Octave Sound Power[dB] Model Power Level[dB(A)] 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TWR706OAl 74 58 1 75 1 66 1 68 1 66 1 59 1 55 1 52 Note:Rated in accordance with AHRI Standard 270-2008 ©2013 Trane Mechanical Specification Options General Condenser Coil The 4TWR7 is fully charged from the The outdoor coil provides low airflow factory for matched indoor section resistance and efficient heat transfer. and up to 15 feet of piping.This unit is The coil is protected on all four sides by designed to operate at outdoor ambient louvered panels. temperatures as high as 115°F.Cooling Low Ambient Cooling capacities are matched with a wide se- As manufactured,this unit has a cooling lection of air handlers and furnace coils capability to 55°F. For low ambient cool- that are AHRI certified.The unit shall be ing below 55'see Application Guide. certified to UL 1995.Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge,G60 galvanized steel and painted with a weather-resistant powder paint on all louvers and panels.Cor- rosion and weatherproof CMBP-G30 DuraTuffT"" base. OFFICE Refrigerant Controls COPY Refrigeration system controls include condenser fan,compressor contactor and high pressure switch.High and low pressure controls are inherent to the compressor.A factory installed liquid line CITY OF ARLINGTON drier is standard. Compressor 13UILDING3 DEPARTMENT The Climatuff®2-stage compressor APPROVED features internal over temperature and pressure protection and hermetic motor. Other features include:centrifugal oil DATE l �Y pump and modular plugs for electrical connections. NO CHANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING INSPECTOR c us Intertek TRME 05/13 Trane www.trane.com Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS O These Air Handlers are A.H.R.I.certified with various Split System Air Condi- tioners and Heat Pumps(AHRI STANDARD 210/240). Refer to the Split Sys- MODEL GAM5B0C60M51 SB tem Outdoor Unit Product Data Guides for performance data. GAM580C60M51 EA RATED VOLTS/PH/HZ. 208-230/1/60 O s/a"Male Plastic Pipe(Ref.: ASTM 17(35-76) RATINGS O See O.D.Specifications INDOOR COIL—Type Plate Fin Rows—F.P.I. 4-14 Face Area(sq.ft.) 5.96 Tube Size(in.) 3/8 Refrigerant Control TXV Drain Conn.Size(in.) O 3/4 NPT DUCT CONNECTIONS See Outline Drawing olis INDOOR FAN—Type CentrifugalT 'Diameter-Width (In.) 11 X 10 CUSNo.Used 1 Drive-No.Speeds Direct-5 UnilarySiiahHP CFM vs.in.w.g. See Fan Performance Table Intertek No.Motors—H.P. 1 -1 Motor Speed R.P.M. 1050 Volts/Ph/Hz 208-230/1/60 F.L.Amps 7.6 FILTER Filter Furnished? No Type Recommended Throwaway No.-Size-Thickness 1 -22 X 20-1 in. REFRIGERANT R-410A Ref.Line Connections Brazed Coupling or Conn.Size—in.Gas 7/8 Coupling or Conn.Size—in.Liq. 3/8 DIMENSIONS H x W x D Crated(In.) 63-1/4 x 27-1/2 x 25-3/4 Uncrated 61-3/4 x 23-1/2 x 21-3/4 WEIGHT Shipping(Lbs.)/Net(Lbs.) 180/170 GAM5BOC60M51 SB,GAM5BOC60M51 EA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap Without HP With HP BAYEAAC04BK1 Tap 2 Tap 3 BAYEAAC04LG1 BAYEAAC05BK1 Tap 2 Tap 3 BAYEAAC05LG1 BAYEAAC08BK1 Tap 2 Tap 3 BAYEAAC08LG1 BAYEAAC10BK1 Tap 2 Tap 3 BAYEAAC10LG1 BAYEAAC10LG3 Tap 2 Tap 3 BAYEABC15BK1 Tap 3 Tap 4 BAYEABC15LG3 Tap 3 Tap 4 BAYEABC20BK1 I Tap 3 Tap 4 BAYEACC25BK1 Tap 4 Tap 5 00 n If the air handler is applied in downflow or horizontal configurations,the airflow should not exceed 2000 CFM. Airflow above 2000 CFM could result in water blow-off. O Tap 5 can be used but only when the external static pressure is.6"or above. Note: Heating and cooling speeds are the same, factory set at Speed Tap#4. Note: A "G"only signal from the comfort control will run the blower at a lower speed, factory set at Speed Tap#1. See the Sequence of Operation for additional information. Note: Speed Tap 1 is NOT used for two stage systems. Two stage systems will require an airflow adjustment GAWBOC60-SUB-1 D TAG: 5 Ton Convertible Air Handler Black Epoxy Coil - GAM5BOC6OM51 EA Standard Coil - GAM5BOC6OM51 SB 21.75 1.50 14.35 5 90 1.50 E] GAS LINE— F— -- 3.00 LIQUID LINE SEE TABLE SEE TABLE B E 0 I 1.50 1.500 D A O O H 021.8 !o 4 o 1.50 1i 50 17.15 3 11 MINIMUM UNIT CLEARANCE TABLE TO SERVICE COMBUSTIBLE CLEARANCE MATERIAL IREOUIREDI (RECOMMENDED) SIDES 0' 2' FRONT 0' 21' C BACK 0' 0' INLET DUCT 0. OUTLET DUCT 0' 1.50 MODEL NO. Flow M-41UA M-41UA A B C D E F H Control Gas Line Liq.Line GAM5130C60 61.7 1 23.5 1 20.5 51.5 1 20.5 10.3 1 24.9 TXV 7/8 3/13 ©2015 Ingersoll Rand Mechanical Specifications • Unique Cabinet Design • Labeled Panels and connections - Double Wall Foamed and Formed Cabinet System • 1 1/4"to 1" And 3/4"to 1/2" Conduit connection on -Water Proof Cabinet Design Left, Right and Top - R-4.2 Insulating Value (Avg Insulating Value R-8.2) • Molded in 1" Standard Filter rail -Composite Foamed Cabinet Doors • R-410A Thermal Expansion Valve -Sweat Eliminating Cabinet Design • R-22 conversion Thermal Expansion Valve available -Loose Fiber Eliminating Cabinet Design (sold as accessory) -Smooth Cleanable Cabinet Design • Low Voltage Pigtail Connections -2%or Less air leakage • Enhanced Coil Fin Patented - Precision Durable Door Seals • Blow Through Design -Modular Cabinet • High Efficiency ECM Motor • Multi-Position UP/Down Flow Horizontal Left/Right • Maximum Width of 23.5" • Phillips head door fasteners • Compact 20.8" depth with doors removed • Side Return Option • Integrated Horizontal Drain pans • Refrigerant Connections • Soft start fan motor operation • Condensate Connections • Built in fan delay modes • Premarked Conduit Connection Locations • Single Color • Vortica®Blower with Integrated Slide Deck for Easy • Fused 24V Power Removal • Safety Door Switch • Polarized Plug connections on Blower • Aluminum Coil with Integrated Slide Deck for Easy •5 year warranty Removal •10-year warranty registered • Slide in Electric Heaters with polarized plug •Optional extended warranty available connections (sold as accessory) • Polarized Plug connections for Electric Heater • UVC light kit with safety switch and polarized plug connections (sold as accessory) An a.al CERTIFIED,. C US uarEo Intertek Ingersoll Rand 6200 Troup Highway The manufacturer has a policy of continuous product and product data improve- Tyler, TX 75707 ment and it reserves the right to change design and specification without notice. AIRFLOW PERFORMANCE GAM5BOC6OM51 SB,GAM5BOC6OM51 EA EXTERNAL STATIC AIRFLOW(CFM) (in w.g) Speed Taps-230 VOLTS Speed Taps-208 VOLTS 5 4t 3 2 1 5 4t 3 2 1 0 2327 2020 1914 1819 1125 2324 2017 1910 1816 1122 0.1 2285 1980 1873 1780 990 2279 1974 1867 1774 984 0.2 2237 1944 1835 1740 831 2228 1935 1826 1731 822 0.3 2182 1908 1800 1705 600 2171 1896 1789 1693 589 0.4 2125 1869 1756 1659 331 2111 1854 1742 1645 317 0.5 2062 1830 1717 1620 249 2045 1813 1700 1603 232 0.6 1995 1747 1664 1575 187 1975 1727 1644 1555 168 0.7 1922 1707 1629 1540 - 1899 1685 1607 1518 - 0.8 1844 1673 1594 1502 - 1819 1648 1569 1477 - 0.9 1761 1629 1553 1464 - 1733 1601 1525 1436 - NOTES: 1.Values are with wet coil and without filters. 2.Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4.Tap 1 is an continuous fan speed tap. 5.If the air handler is applied in downflow or horizontal configurations,the airflow should not exceed 2000 CFM. Airflow above 2000 CFM could result in water blow-off. 6. t Factory Setting WIRING DATA GAM5BOC6OM51SB,GAM5BOC6OM51 EA 240 VOLT 208 VOLT Heater No. Heater Heater Model of Capacity Amps Minimum Maximum Capacity Amps Minimum Maximum No. Circuits Circuit Overload Circuit Overload kW BTUH Clprcuit Ampacity Protection kW BTUH Circuit perAmpacity Protection No Heater - - 7.6' 10 15 - - 7.6' 10 15 BAYEAAC04BK1 1 3.84 13100 16.0 30 30 2.88 9800 13.8 27 30 BAYEAAC04LG1 BAYEAAC05BK1 1 4.80 16400 20.0 35 35 3.60 12300 17.3 31 35 BAYEAAC051_G1 BAYEAAC08BK1 1 7.68 26200 32.0 50 50 5.76 19700 27.7 44 45 BAYEAAC08LG1 BAYEAAC10BK1 1 9.60 32800 40.0 60 60 7.20 24600 34.6 53 60 BAYEAAC10LG1 BAYEAAC10LG3 1-3 PH 9.60 32800 23.1 37 40 7.20 24600 20.0 34 35 BAYEABC15LG3 1-3 PH 14.40 49200 34.6 52 60 10.80 36900 30.0 46 50 BAYEABC15BK1 -Circuit 1 O 2 9.60 32800 40 60 60 7.20 24600 34.6 53 60 BAYEABC15BK1-Circuit 2 4.80 16400 20 25 25 3.60 12300 17.3 22 25 BAYEABC20131<1 -Circuit 1 O 9.60 32800 40 60 60 7.20 24600 34.6 1 53 60 2 BAYEABC20BK1 -Circuit 2 9.60 32800 40 50 50 7.20 24600 34.6 43 45 BAYEACC25131<1®O-Circuit 1 O 9.60 32800 40 60 60 7.20 24600 34.6 53 60 BAYEACC25BK1 -Circuit 2 3 9.60 32800 40 50 1 50 7.20 24600 34.6 43 45 BAYEACC25BK1 -Circuit 3 4.80 16400 20 25 1 25 3.60 112300 17.3 22 25 Note:`Motor Amps O MCA and MOP for circuit 1 contains the motor amps O If the air handler is applied in downflow or horizontal configurations,the airflow should not exceed 2000 CFM. Airflow above 2000 CFM could result in water blow-off. O Tap 5 can be used but only when the external static pressure is.6"or above. COMMERCIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington •18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF CONSTRUCTION DRAWINGS AND ALL OTHER INFORMATION OUTLINED/N THE MECHANICAL PERMIT SUBMITTAL REQUIREMENTS, IF APPLICABLE. Type of Permit: F7 New Installation FV—] Replacement 7 Alteration Project Address: 328 S. Stillaguamish, Arlington, WA Parcel #: Remove and replace split heat pump. Using SNOPUD Project Description:rebate for high efficiency replacement Valuation:14,000 Owner:PRJ LLC Phone#: 360-474-8686 Address: 323 2nd St. City: Snohomish State: WA Zip: 98290 Email Address: cleopatra_j49@hotmail.com Paula Johnson Contact Person: Phone#: 360-474-8686 Address: 323 2nd St. City: Snohomish State: WA Zip: 98290 Email Address:cleopatra_j49@hotmail.com Contractor Name:Evergreen State Heat & A/C Phone#:425-252-31 14 Contractor Address:2120 Pacific Ave City: Everett State:WA Zip: 98201 Email: mark@essmwa.com Contractor License Number: evergee0220T Expiration: nov '16 Please indicate type of number of appliances: FURNACE CONDENSING UNIT GAS PIPING OUTLET BOILER HEAT PUMP (multi-split) 1 UNIT HEATER CHILLER HEAT PUMP (mini-split) PAINT BOOTH COOLER HEAT PUMP (other) TYPE I HOOD AC(air cooled) HEAT REJECTION EQUIP TYPE II HOOD AC(water cooled) VENTILATION SYSTEM AST AC (evaporator) PACKAGED UNIT UST AC (VRF) DRYER OTHER I hereby certify that the above information is correct and that the construction on. and the occupancy and the use of the above- described property will be in accordance with the laws, rules and regulation of the State of Washington. Applicants Signature �Czhg�� Date 01/20/2016 Applicants Printed Name Mark Payne FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received Permit#: 886 Permit Date: 01/20/16 Permit Type: COMMERCIAL MECHANICAL Project Name: PRJ LLC Applicant Name: Evergreen State Heat and A/C Applicant Address: 2120 Pacific Ave Applicant, City, State, Everett,WA 98201 Zip: Contact: Paula Johnson Phone: 360-474-8686 Email: mark@essmwa.com Scope of Work: Remove/replace split heat pump. Using SNOPUD rebate for hight efficiency replacement. Valuation: 14000.00 Square Feet: 0 Number of Stories: 1 Construction Type: Occupancy Group: ID Code: Permit Issued: Permit Expires: Form Permit Type: Status: IN PROCESS Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 2870048 328 S Stillaquamish Ave Arlington Rehab 651 Medical&Other Partners LLC Health Services Contractors Contractor Primary Contact Phone Address Contractor Type License License# Evergreen State Heat MECHANICAL Labor and Mark Payne 425-252-3114 2120 Pacific Ave EVERGSS928RN and A/C CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status CIO. 04/14/2016 MECHANICAL 03/01/2016 BUILDING Approved ROUGH-IN Plan Reviews Date Review Type Description Assigned To Review Status 01/20/2016 COMMERCIAL BUILDING MECHANICAL Fees Fee Description Notes Amount Mechanical Fee(Enter Fixture Fee) $25.00 Mechanical Base Permit Fee $25.00 Mechanical Commercial Plan Review Table 4-1 $250.00 Total $300.00 Attached Letters Date Letter Description 01/22/2016 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 01/28/2016 Evergreen State Sheet Metal Check#29106 Kristin Foster $300.00 Inc. Outstanding Balance $0.00 Uploaded Files Date File Name 04/29/2016 1594793-328 S.Stillaquamish.docx 01/28/2016 1452577-Permit.pdf 01/21/2016 1433492-Specifications.pdf 01/20/2016 1433036-BLD 886 Agplication.pdf CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 -' PHONE; (360)403-3551 BUILDING PERMIT Address:328 S.Stillaquamish Permit#:886 Parcel#:2870048 Valuation: 14000.00 OWNER APPLICANT CONTRACTOR Name:Arlington Rehab Partners LLC Name:Evergreen State Heat and A/C Name:Evergreen State Heat and A/C Address:5962 La Place Ct Ste 170 Address:2120 Pacific Ave Address:2120 Pacific Ave City,State Zip:Carlsbad,CA 92008 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:360-474-8686 Phone:425-252-3114 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Evergreen State Heat and A/C Name: Address:2120 Pacific Ave Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-252-3114 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Mechanical CODE YEAR: 2012 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1 l0/IRC1I0. SALES TA ' 'ICE:Sales tax relating to construction and o slruction materials in the City of Arlington must be reported on your sales tax return form an ed ity of iglon#3101. Signature Print Name Date Released By Dale CONDITIONS Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 1/22/2016 Mechanical Fee(Enter Fixture Fee) $25.00 1/22/2016 Mechanical Permit Base Fee $25.00 1/22/2016 Mechanical Plan Review Fee $250.00 Total Due: $300.00 Total Payment: $0 00 Balance Due: $300.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon TRA E® 4TWR7060-SUB-1 TAG: 0 5 Ton Split System Heat Pump — 1 Ph NOTE:All dimensions are in mm/inches. 4TWR7060A B Product Specifications OUTDOOR UNIT OO 4TWR706OA1000A POWER CONNS.—V/PH/HZ® 208/230/1/60 MIN.BIRCH.CIR.AMPACITY 41 BR.CIR.PROT.RTG.—MAX.(AMPS) 60 SERVICE PANEL C COMPRESSOR CLIMATUFF®-SCROLL NO.USED-NO.STAGES 1 -2 ELECTRICAL AND REFRIGERANT VOLTS/PH/HZ 208/230/1/60 COMPONENT CLEARANCES PER PREVAILING CODES. R.L.AMPS O-L.R.AMPS 28.8-152.9 FACTORY INSTALLED START COMPONENTS® NO INSULATION/SOUND BLANKET NO COMPRESSOR HEAT YES TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 15 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR OUTDOOR FAN PROPELLER DIRECTLY ON UNIT,AND SHOULD BE AT LEAST 305(12"I FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. DIA.(IN.)-NO.USED 27.6-1 TYPE DRIVE-NO.SPEEDS DIRECT-1 CFM @ 0.0 IN.W.G.® 4760 OL NO.MOTORS-HP 1 -1/4 ELECTRICAL SERVICE MOTOR SPEED R.P.M. 825 PANEL VOLTS/PH/HZ 208/230/1/60 F.L.AMPS 1.30 K OUTDOOR COIL—TYPE SPINE FINTM FIG. 1 ROWS-F.P.I. 2-24 zs 1 FACE AREA(SQ.FT.) 29.15 A TUBE SIZE(IN.) 3/8 REFRIGERANT CONTROL EEV 22.2(7/8) DIA. HOLE REFRIGERANT R-410A Low VOLTAGE LBS.—R-410A(O.D.UNIT)(D13 LBS.-3 OZ. 28.6 1- /8) DIA. FACTORY SUPPLIED YES HOLE INTCONTROL LINE SIZE-IN.O.D.GAS© 1-1/8 BOX BOTTOM FOR ELECTRICAL H PowER SUPPLY F LINE SIZE-IN.O.D.LIQ.(D 3/8 N.O. FOR ALTERNATE ELECTRICAL ROUTING CHARGING SPECIFICATION y J AS LINE 1/4 TURN BALL SERVICE VALVE, "D" SUBCOOLING 10'F LIQUID LINE SEAM CE VALVE, I.D. FEMALE BRAZED CONNECTION WITH I/4"SAE "E" I.D. FEMALE BRAZE G FLARE PRESSURE TAP FITTING. DIMENSIONS H X W X D FLARECPRESSSURE"TAP°FITTTINGS. CRATED(IN.) 51.0 X 35.1 X 38.7 WEIGHT SHIPPING(LBS.) 330 NET(LBS.) 293 F{ k UID LINE SERVICE VE, "E' I.D. FEMALE FZED CONNECTION H 1/4" SAE FLARE OO Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program,which is based SSURE TAP FITTING. OnARl standard 210/240.In order to achieve ARI standard rating,the indoor fan time delay on the comfort control AS LINE SERVICE VALVE, D' I.D. FEMALE BRAZED must be enabled. ONNECTION WITH I/4" SAE FLARE ® Rated in accordancewilhARlstandard270. RESSURE TAP FITTING. O Calculated in accordance with Natl.Elec.Codes.Use only HACR circuit breakers or fuses. D Standard Air—DryCoil—Outdoor FIG. 2 From Dwg.D152635 O This value approximate.For more precise value see unit nameplate. O Max.linear length 60 ft.;Max.lift-Suction 25 ft.;Max lift-Liquid 25 ft.For greater length consult refrigerant piping software Pub.No.32-3312-0*(*denotes latest revision). �MOD'I(LSOA BASE A B C D E F c x J K O This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute tta7 sas 870 sa zts as 730 minimumbmnchcirouftampaciryandmax.fusesize.Thevalueshownisthebranchcimufiselectioncurrent. w a ( ) ( ) ( ) t-va 3/8 t5z(s) ( ) ( ) ( ) ( ) © No means no start components.Yes means quick start kit components.PTO means positive temperature coefficient 45-1/8 37-1/4 34-1/4 3-7/8 8-5/8 3-3/8 28-3/4 starter. Sound Power Level A-Weighted Sound Full Octave Sound Power[dB] Model Power Level [dB(A)] 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TWR706OAl 74 58 75 66 68 66 59 55 52 Note:Rated in accordance with AHRI Standard 270-2008 ©2013 Trane Mechanical Specification Options General Condenser Coil The 4TWR7 is fully charged from the The outdoor coil provides low airflow factory for matched indoor section resistance and efficient heat transfer. and up to 15 feet of piping.This unit is The coil is protected on all four sides by designed to operate at outdoor ambient louvered panels. temperatures as high as 115°F.Cooling Low Ambient Cooling capacities are matched with a wide se- As manufactured, this unit has a cooling lection of air handlers and furnace coils capability to 55°F. For low ambient cool- that are AHRI certified.The unit shall be ing below 55'see Application Guide. certified to UL 1995.Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, G60 galvanized steel and painted with a weather-resistant powder paint on all louvers and panels.Cor- rosion and weatherproof CMBP-G30 DuraTuffTm base. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch.High and low pressure controls are inherent to the compressor.A factory installed liquid line drier is standard. Compressor The Climatufff 2-stage compressor features internal over temperature and pressure protection and hermetic motor. Other features include:centrifugal oil pump and modular plugs for electrical connections. Zal CERTIFIED-'I, C US UnitarySmallHP AHRI Standard 1 41 G/STEM Intertek TAWE° 05/13 Trane www.trane.com Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. GAWBOC60-SUB-1 D TAG: 5 Ton Convertible Air Handler Black Epoxy Coil - GAM5BOC6OM51 EA Standard Coil - GAM5BOC6OM51 SB 21.75 I.50 .50 14.35 5.90 GAS LINE F 3.00 LIQUID LINE SEE TABLE SEE TABLE B E Oo 0 1.50 I .500 D A O O H 0 21.8 1.50 I� 50 17.15 3.11 MINIMUM UNIT CLEARANCE TABLE TO SERVICE COMBUSTIBLE CLEARANCE MATERIAL (RECOMMENDED) (REQUIRED) SIDES 0" 2" FRONT 0" 21" BACK 0" 0" OINLET DUCT 0" UTLET DUCT 0" 1.50 MODEL NO. Flow R-41CIA R-41CIA A B C D E F H Control Gas Line Liq.LinBRAZE JMAZF_ GAM5BOC60 61.7 1 23.5 1 20.5 51.5 1 20.5 10.3 1 24.9 TXV 7/8 3/8 ©2015 Ingersoll Rand PRODUCT SPECIFICATIONS 0 These Air Handlers are A.H.R.I.certified with various Split System Air Condi- PRODUCT SPECIFICATIONS tioners and Heat Pumps(AHRI STANDARD 210/240). Refer to the Split Sys- MODEL GAM5BOC6OM51 SB tem Outdoor Unit Product Data Guides for performance data. GAM5BOC6OM51 EA RATED VOLTS/PH/HZ. 208-230/1/60 3/4"Male Plastic Pipe(Ref.: ASTM 1785-76) RATINGS(D See O.D.Specifications INDOOR COIL—Type Plate Fin Rows—F.P I. A"Imp 4- 14 Face Area(sq.ft.) 5.96 Tube Size(in.) 3/8 UnitarySmallAC Refrigerant Control TXV Drain Conn.Size (in.) O 3/4 NPT DUCT CONNECTIONS See Outline Drawing INDOOR FAN—Type Centrifugal Diameter-Width (In.) 11 X 10 C TUS C www.ahridirectory.org No.Used 1 t,sreo Unitary Small HP Drive-No.Speeds Direct-5 CFM vs.in.w.g. See Fan Performance Table I ntertek No.Motors—H.P. 1 - 1 Motor Speed R.P.M. 1050 Volts/Ph/Hz 208-230/1/60 F.L.Amps 7.6 FILTER Filter Furnished? No Type Recommended Throwaway No.-Size-Thickness 1 -22 X 20- 1 in. REFRIGERANT R-41 OA Ref.Line Connections Brazed Coupling or Conn.Size—in.Gas 7/8 Coupling or Conn.Size—in.Lig. 3/8 DIMENSIONS H x W x D Crated(In.) 63-1/4 x 27-1/2 x 25-3/4 Uncrated 61-3/4 x 23-1/2 x 21-3/4 WEIGHT Shipping (Lbs.)/Net(Lbs.) 180/170 GAM5BOC6OM51SB, GAM5BOC6OM51EA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap Without HP With HP BAYEAAC04BK1 Tap 2 Tap 3 BAYEAAC04LG1 BAYEAAC05BK1 Tap 2 Tap 3 BAYEAAC05LG1 BAYEAAC08BK1 Tap 2 Tap 3 BAYEAAC08LG1 BAYEAAC10BK1 Tap 2 Tap 3 BAYEAAC10LG1 BAYEAAC10LG3 Tap 2 Tap 3 BAYEABC15BK1 Tap 3 Tap 4 BAYEABC15LG3 Tap 3 Tap 4 BAYEABC20BK1 Tap 3 Tap 4 BAYEACC25BK1 Tap 4 Tap 5 00 O If the air handler is applied in downflow or horizontal configurations,the airflow should not exceed 2000 CFM. Airflow above 2000 CFM could result in water blow-off. O Tap 5 can be used but only when the external static pressure is.6"or above. Note: Heating and cooling speeds are the same, factory set at Speed Tap#4. Note: A "G"only signal from the comfort control will run the blower at a lower speed, factory set at Speed Tap#1. See the Sequence of Operation for additional information. Note: Speed Tap 1 is NOT used for two stage systems. Two stage systems will require an airflow adjustment AIRFLOW PERFORMANCE GAM5BOC6OM51 SIB, GAM5BOC6OM51 EA EXTERNAL STATIC (in w.g) AIRFLOW(CFM) Speed Taps-230 VOLTS Speed Taps -208 VOLTS 5 4t 3 2 1 5 4t 3 2 1 0 2327 2020 1914 1819 1125 2324 2017 1910 1816 1122 0.1 2285 1980 1873 1780 990 2279 1974 1867 1774 984 0.2 2237 1944 1835 1740 831 2228 1935 1826 1731 822 0.3 2182 1908 1800 1705 600 2171 1896 1789 1693 589 0.4 2125 1869 1756 1659 331 2111 1854 1742 1645 317 0.5 2062 1830 1717 1620 249 2045 1813 1700 1603 232 0.6 1995 1747 1664 1575 187 1975 1727 1644 1 1555 168 0.7 1922 1707 1629 1540 - 1899 1685 1607 1518 - 0.8 1844 1673 1594 1502 - 1819 1648 1569 1477 - 0.9 1761 1629 1553 1464 - 1733 1601 1525 1436 - NOTES: 1.Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4.Tap 1 is an continuous fan speed tap. 5. If the air handler is applied in downflow or horizontal configurations, the airflow should not exceed 2000 CFM. Airflow above 2000 CFM could result in water blow-off. 6. t Factory Setting WIRING DATA GAM5BOC6OM51SB,GAM5BOC6OM51 EA 240 VOLT 208 VOLT Heater No. Heater Heater Model of Capacity Amps Minimum Maximum Capacity Amps Minimum Maximum No. Circuits p Circuit Overload p Circuit Overload kW BTUH CPcuit Ampacity Protection kW BTUH Crer Ampacity Protection No Heater - - - 7.6* 10 15 - - 7.6* 10 15 BAYEAAC04BK1 1 3.84 13100 16.0 30 30 2.88 9800 13.8 27 30 BAYEAAC04LG1 BAYEAAC05BK1 1 4.80 16400 20.0 35 35 3.60 12300 17.3 31 35 BAYEAAC05LG1 BAYEAAC08BK1 1 7.68 26200 32.0 50 50 5.76 19700 27.7 44 45 BAYEAAC08LG1 BAYEAAC10BK1 1 9.60 32800 40.0 60 60 7.20 24600 34.6 53 60 BAYEAAC10LG1 BAYEAAC10LG3 1-3 PH 9.60 32800 23.1 37 40 7.20 24600 20.0 34 35 BAYEABC15LG3 1-3 PH 14.40 49200 34.6 52 60 10.80 36900 30.0 46 50 BAYEABC15BK1 -Circuit 1 9.60 32800 40 60 60 7.20 24600 34.6 53 60 2 BAYEABC15BK1 -Circuit 2 4.80 16400 20 25 25 3.60 12300 17.3 22 25 BAYEABC20BK1 -Circuit 1 1 2 9.60 32800 40 60 1 60 7.20 246001 34.6 53 60 BAYEABC20BK1 -Circuit 2 9.60 32800 40 50 50 7.20 24600 34.6 1 43 45 BAYEACC25BK1®O-Circuit 1 T 9.60 32800 40 60 60 7.20 24600 34.6 53 60 BAYEACC25BK1 -Circuit 2 3 9.60 32800 40 50 50 7.20 24600 34.6 43 45 BAYEACC25BK1 -Circuit 3 4.80 16400 20 1 25 25 3.60 12300 17.3 22 25 Note:*Motor Amps O MCA and MOP for circuit 1 contains the motor amps O If the air handler is applied in downflow or horizontal configurations,the airflow should not exceed 2000 CFM. Airflow above 2000 CFM could result in water blow-off. ®Tap 5 can be used but only when the external static pressure is.6"or above. Mechanical Specifications • Unique Cabinet Design • Labeled Panels and connections - Double Wall Foamed and Formed Cabinet System • 1 1/4"to 1" And 3/4" to 1/2" Conduit connection on -Water Proof Cabinet Design Left, Right and Top - R-4.2 Insulating Value (Avg Insulating Value R-8.2) • Molded in 1" Standard Filter rail - Composite Foamed Cabinet Doors • R-410A Thermal Expansion Valve - Sweat Eliminating Cabinet Design • R-22 conversion Thermal Expansion Valve available - Loose Fiber Eliminating Cabinet Design (sold as accessory) - Smooth Cleanable Cabinet Design • Low Voltage Pigtail Connections -2% or Less air leakage • Enhanced Coil Fin Patented - Precision Durable Door Seals • Blow Through Design - Modular Cabinet • High Efficiency ECM Motor • Multi-Position UP/Down Flow Horizontal Left/Right • Maximum Width of 23.5" • Phillips head door fasteners • Compact 20.8" depth with doors removed • Side Return Option • Integrated Horizontal Drain pans • Refrigerant Connections • Soft start fan motor operation • Condensate Connections • Built in fan delay modes • Premarked Conduit Connection Locations • Single Color • Vortica®Blower with Integrated Slide Deck for Easy • Fused 24V Power Removal • Safety Door Switch • Polarized Plug connections on Blower • Aluminum Coil with Integrated Slide Deck for Easy •5 year warranty Removal • 10-year warranty registered • Slide in Electric Heaters with polarized plug •Optional extended warranty available connections (sold as accessory) • Polarized Plug connections for Electric Heater • UVC light kit with safety switch and polarized plug connections (sold as accessory) Unitary Small AC C USwww.a CERTIFIErg �ISTEO Unitary Small HP AHRI Standard i 40 ntertek Ingersoll Rand 6200 Troup Highway The manufacturer has a policy of continuous product and product data improve- Tyler, TX 75707 ment and it reserves the right to change design and specification without notice.