Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18660 58TH AVE NE_BLD882_2026
' CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address: Permit#:882 Parcel#:0235820 Valuation:2000.00 OWNER APPLICANT CONTRACTOR Name:Stoddard International Name:Alarmtech Inc Name:Alarmtech Inc Address: 18660 58TH AVE NE Address:P.O.Box 186 Address:P.O.Box 186 City,State Zip:Arlington,WA 98223 City,State Zip:Mountlake Terrace,WA 98043 City,State Zip:Mountlake Terrace,WA 98043 Phone: Phone:425-931-7066 Phone:425-931-7066 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2012 STORIES: 1 CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and co led i of Arlington#3101 Signatur Print Namc Date Released By Da c CONDITIONS Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED,THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 1/14/2016 Fire Alarm Fee $95.30 1/14/2016 Fire Review Fee $100.00 Total Due: $195.30 Total Payment: $0.00 Balance Due: $195.30 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon i �i n ,ti. -. ., ��,y .i� r 1 �� •L pr-em-c Fc=E- 1?5. so Permit Information Date 1/14/2016 Permit Number 882 Project Name Stoddard International Applicant Name Alarmtech Inc Applicant Address P.O. Box 186 City, State,Zip Mountlake Terrace,WA 98043 Contact Jesse Holfak Phone 425-931-7066 Email Permit Type Fire Alarm Site Address Valuation 2000.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 1 Proposed Use New Fire Alarm Assigned To Kristin Foster Property Information Owner Information Parcel#:0235820 Stoddard International Stoddard International 18660 58TH AVE NE 18660 58TH AVE NE Arlington,WA 98223 Contractors Contractor Name I Primary Contact Phone Email Contractor Type License License# Alarmtech Inc Jesse Holfak 425-931-7066 1CONTRACTOR JALARMTECH INC LARMI*964NR Review Date Type I Description I Target Date Completed Date Assigned To Status 1/14/2016 113LD 1 11/21/2016 lKevin Olander lin Review Uploaded Files C Upload File Date File 1/14/2016 11:07:57 AM F�ermit. df h nil - _j FIRE ALARM PERMIT APPLICATION Department of Community& Economic Development City of Arlington •18204 59th Ave NE•WA 98223• Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY THREE(3)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION.INCLUDE ELECTRICAL PLANS WHERE APPLICABLE.ALSO,INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS,(POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) W. New Fire Alarm ❑ Fire Alarm Alteration/Addition Project Address: K�' _O _ e Parcel ID#: Number of Zones/Panels: I Building Area(Sq Ft): Valuation: goon Owner: Phone Number: Address: City: State: Zip Code: Contact Person: Phone Number: Cell Phone: E-mail: Address: City: State: Zip Code Contractor: A,0.r W\A ec_�\ rt--C Phone Number: Address: '�O 'kl 151< ll�(b City: - L)c Zip Code: 21 `i3 Contractor's License Number: A t o'er 1 1� g LGl N Z Expiration Electrical Contractor: Phone Number: Address City: State: Zip Code: Contractor's License Number: Expiration I hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described property will be accordance with the laws, rules and regulations of the State of Washington. The applicant will be responsible for providing a method of safely accessing roof for inspection. A final inspection and approval shall be obtained when the re-roofing is complete. � M� App cants Signature Date Print Applicants Name Received JAN 13 2016 FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received WEB Form-130 Page 1 of 1 7/10CJY i Stoddard International Fire Alarm System Submittals OFFICE COPY Site Address: 18660 58th Ave NE Arlington, WA 98223 CITY OF AARLINGTON BUILDING DEPARTMENT APPROVED OATE NO CHANGES AUTHORIZED UKESS APPROVED BY THE BUILDING INSPECTOR PO Box 186 Mountlake Terrace, WA 98043 Voice (425)775-4208 Fax (425)775-5410 Received ,JAN 13 2016 yw R-- !Tmg3o 9l4lQAA P POT Pi 00 n P�LIS(, Fire Alarm Control Panel Features • 30 Analog Addressable Points.Any combination of detectors/ modules • 3.5 Amp Power Supply.Expandable to 315 amps • 2 NAC circuits rated at 3 amps maximum,expandable to 188. • Built-in UL Listed iP Communicator Built-in email event notification and report capability. • Optional Dual Line Digital Alarm Communicator • System wide synchronization of Potter/AMSBCO,Gentex, Cooper/Wheelock,and System Sensor signals. • No twisted or shielded wiring required. • Cabinet will accommodate up to 18AH batteries.Panel will charge Lip to 55AH. • Capable of Class A or Class B wiring configurations • Built-in NEPA 72 compliant smoke detector sensitivity test • Dead-front cabinet design • 1000 Event History Buffer Product includes a 5 Potter/Nohmi Protocol Features year warranly • Less than 4 second polling time S735 • 7165-0328:0195 LED's visible from 360° • Adjustable Smoke Detector Sensitivity • Adjustable Heat Detector Temperature • High Temperature Heat Detector as fixed temp • Drift Compensation • Maintenance Alerts • Day/Night Mode Description The P100 is a small analog/addressable fire alarm control panel with a The entire system,including the SLC,NACs and P-Link may be total of 30 points.The points may be any combination of smoke sensors, converted with a CA-6075 Class A module.The entire system is heat detectors or modules.This panel has a 3.5 amp power supply that is programmed using a Windows based computer software and requires distributed across two Notification Appliance Circuits(NACs). the use of a software programming software key. The NAC circuits are rated at a maximum of 3 Amps each.All of The P 100 can communicate to a monitoring station using the optional the outputs may be configured for notification or auxiliary power.In UL listed UD-1000 traditional two line alarm communicator or the addition,each NAC can be programmed for strobe synchronization and built-in UL listed iP communicator.The UD-1000 connects to the main utilizes Quadrasync for strobe synchronization across circuits of various board and has two phone line jacks provided.The 1P communicator brands. uses a RJ-45 connection and when connected to the internet may The cabinet will hold two 12 volt,8 amp/hour batteries or two 12 volt, be programmed to E-mail system status,history reports or the 18 amp/hour batteries.The system when fully loaded will charge 55 configuration file.The panel may be updated remotely using the amp/hour batteries.Anything larger than 18 amp/hour will require an UD-1000. external battery cabinet the SSU-00050. The panel has the Potter P-Link connection for expansion with remote atmunciators,intelligent power supplies and other optional modules. The P-Link will support 31 accessories in any combination.The RA-6075 is a 2 x 16 LCD annunciator.The RA-6500 offers a larger 4 x 40 line LCD display that allows points and descriptions to be shown simultaneously. PotterElectrir Signal Company,LLC • St.Louis,MO ©PpTT� 800-325-3936 • www.potiersignal.corn Plus 08830033-REV A PAGE I OF 4 08,12 P POTTT PI 00 Y J Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to thirty(30)addressable devices or modules in any combination.The SLC is not restricted by any special wire requirements and may be wired with any wire that complies witli the NEC. SLC Loop Devices Device Description I PSA Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PSHA Combination Analog Photo Electric Smoke/I Icat Detector—a smoke detector with a listed obscuration of 1.02 to 3.83 percent i obscuration and a fixed temperature 135'Fahrenheit heat detector- FHA Analog Fixed Temperature Heat Detector that is selectable from 135'F to 185°F RHA Analog Rate or Rise Heat Detector that has a fixed temperature selection from 135T and 174°F and also will alarm if the temperature increase 12-15°F in one minute j — AB-6 6"round base that is mounted to an electrical box and wired for connection of one of the above sensors AB-.{ 4"round base that may be mounted to an electrical box and wired for connection to the above sensors A1B� lsolater base that interrupts a short in a SLC and prevents the short from aflccting protected devices on the loop ARB Addressuble Relay Base that contains two relays controlled by the SLC One relay is rated at 8 amps at 240 VAC/30VDC and the other is rated at 2 amps 240 VAC/30 V DC ASB Addressable Sounder Base that contains and addressable sounder module that may be configured for local,group and all call."The sounder follows the pattern sent to the device. Modules Device Description MCM Miniature Contact Module provides a small fool print contact module for mounting inside an enclosure,typically used to nionilor I a pull station l SCM-4 Single Contact Module is a standard contact module with an LED that mounts into a 4"square electrical box.The contact moni- tors normally open contacts and the LED will provide an indication when the device has activated. DCNI-4 Dual Contact Module is a device that can monitor two distinct inputs with a single device or in a Class A mode.The DCM-4 mounts into a 4"square electrical box and has a cover plate with an LED as a status indication. TRM-4 1 `rwin Relay Module provides two form C relays that simultaneously active when the module is triggered by the control panel. 1 Each relay is rated for 2 amps at 24VDC or 0.5 amps at 125VAC. I 111 ONl-4 Monitored Output Module is a power switching module that monitors the circuit that is controlled by the control panel. CCIZM 4— Conventional Input Zone Module is used to connect conventional smoke detectors to the system that receive their power from the � module.'Phis module is like a conventional zone on the SLC i SO Short Circuit lsolater interrupts a short on the SLC and prevents the short from affecting protected devices on the loop.These or —1 the A1B are required in Class A,Style 7 installations. — Potter Electric Signal Cornpant;LLC • S;.Louis,MO Q1 800-325-3936 • tvww.pottersignal.cotn 98830033-RFV A PAGE 2 OF 4 08/12 P POTTTzj� Pi 00 Fire Alarm Control Panel SLC Features P-Link The Potter/Nohmi protocol is a digital protocol with a proven design The P100 has a proprietary communication protocol that communicates for reliability and noise immunity.The system does not require special through a RS-485 connection to field devices.Up to thirty-one cable or conductors for connection of the Signaling Line Circuit as (3 1)devices may be connected to a single P-Link connection.The long as the cable is compliant with NFPA 70 and NFPA 72.The system P-Link includes the com mtmication terminals and regulated 24 VDC allows for Class A or Class B installations as well as"T-Taps.' connection for the field devices.The field devices may be any of the The total polling time for the protocol is about four(4)seconds which following: allows two polling cycles in the ANSI/UL 864 requirement of alarms RA-6075—2 x 16 LCD annunciator with a key pad in a locked metal reporting in less than ten seconds. Each loop is capable of 127 points enclosure. with the exception of the 11100 and P200. RA-6500—4.x 40 LCD annunciator with a key pad in a locked metal Sensor Features enclosure PSN-1000(E)— 10 amp;remote intelligent power supply with 6 NACs, �1ne sensors through the fire alarm control panel provide a real time status as to the condition of the system.The smoke defector 2 l/Os and a II-Link repeater sensitivity,heat detector temperature level and drift compensation CA-6075—Class A convertor that converts the SLC,NACs and P-Link as all programmable options.The system also allows for a day/night connection mode where the panel automatically adjusts the sensitivity depending UD-1000—tJL listed,Dual line telephone alarm communicator on the time of day.To assist in the reduction ol'false alarms.the smoke detectors also have a maintenance warning that sends a trouble signal Ethernet/I.P. Connection when a detector is dirty to the point that it can no longer maintain the The 11100 is shipped standard with an Ethernet connection.This programmed sensitivity. connection is the programming port and may be connected to a building Programming Wide Area Network(WAN)or Local Area Network(LAN).Once connected to the internet,the panel may be selectively programmed to The programming of the P100 is accomplished through a Windows E-mail alarm conditions.trouble conditions.supervisory conditions, based software program.The program is intuitive in drag and drop test.Event History and detector status.An e-mail may be sent to the of points into zones for easy system configuration.There is a total of panel and the panel will e-mail the event history,detector status. 99 zones that may be configured.The software requires the use of a configuration file or server status to an authorized Email account. solhware programming key to communicate to the P100.The system utilizes a standard Ethernet cable for connection between the computer Ill addition,the Ethernet connection is UL listed as an I.P. and the control panel. communicator.The I.P.communicator is listed to report to the UL listed Sur-Gard Ill I.P.receiver.The I.P.communicator replaces the traditional User Interface less reliable alarm communicator transmitter that utilized telephone lines.The I.P.communicator is an active method of connection and 'The fire alarm control panel has a 4 x 40 LCD display to provide communication to the monitoring station. information to the system status.The keypad has navigation keys to allow nnanipulaliou of the Menu on board the panel.The panel is shipped standard with the following LEDs: • AC Power—Green • Alarm—Red • Earth Fault—Amber • Supervisory-Amber • Silenced-Annber • Trouble-Amber The common buttons include a Silence,Reset.Acknowledge and Drill. All of the buttons are accessible once the locked door is opened. Potter Electric Signal Company,LLC St.Louis,MO © `'��rj 800-325-3936 • www.pottersignai.com � F ft Vi 48830033-REV A PAGE 3 OF 4 08,1_2 P POTTER PI 00 P/US� Fire Alarm Control Panel Specifications p TOP . DEPTH=3.75" Electrical Specs: AC Mains _1 3.0 Amps`ar 120 VAC 50/60 HZ I DOOR=16.07" _J 2.0 Amps((%240 VAC 50/60 HZ BACKBOX=15.77" DEPTH=3.84" Battery 130 n1A Standby • 220mA Alarm • • 3.5 Amps power for NACs.I/O,and P-Link • 3 Amps per NAC.regulated • ° © I .o • Battery Charger range 8-55 Ali o u oQ • Battery Charger voltage 27.3 VDC • P-Link maximum current of I Amp Cabinet • 16 gauge Cold rolled steel with removahle LEFT SIDE RIGHTSIDE locked door • Dimensions—16"W x 1711 x 3 7/s'D BOTTOM ° DWG#593-1 • Dead front to cover all electronics • L.exan viewing window Temperature and Humidity This fire alarm control is listed and approved for operation in an incloor application with temperature range fluctuations of 32°to 1201(0°C to 49°C) with a maximum humidity of 93%non-condensing.The ideal temperature is 77°1� +-/- 10°F(25°C+/-5°C). Standards The P100 series fire alarm control panel complies with the following standards and codes, • NFPA 13.70 and 72 • ANSI/UL 864 o Local(L).Remote Station(RS),Central Station(CS).Propriety(PPU).Auxiliary(AUX) o Type of Service:Automatic(A),Manual(M),Water now(WF)Sprinkler Supervisory(SS) o Type ol'Signaling: Digital Alarm Communicator(DAC),March Time(March).Non Coded(NC'),Reverse Polarity(Rev Pot),Other Technologies(OT) • IBC 2000,2003,2006,2009.2012 Potter Electric Signal Company,LLC • St.Louis,MO ©POTrep a 800-325-3936 • www.poticrsionai.com �PISX 483003 3-RF V A PAGE 4 OF 4 08/12 1 @POTTER APS-SA/APS-DA The Symbol of Protection ADDRESSABLE PULL STATION SINGLE/DUAL ACTION Features: 1 Durable Die Cast Manual Pull Station 1 t Matching Fire Alarm Control Panel Key • Mounts in Single Clang Box • Single or Dual Action • Compatible with all PFC-6000,PFC-8000.and P-Series Panels PULL DOWN 1 � Rated Voltage 22 to 24 VDC Standby Current Draw 0.325 mA Alarm Current Draw 0.325 mA Temperature Range 32°F to 1200F(0°C to 49°C) Relative Humidity Range 0 to 93%(non-condensing) C UL M LISTED APS-SA Addressable Pull Station Single Action 1430810 APS-DA Addressable Pull Station Dual Action 1430811 Description ADA Compliance The APS-SA and APS-DA addressable manual pull stations are non- The APS series is required to be mounted between 42"(106.7 cm)and coded that provide an addressable point to a Potter alarm system. The 48" (121.9 cm) from the finished Iloor. The maximum side reach is APS series has terminals that allow the signaling line circuit(SLC)to be allowed to be 54 inches(137.2 cm). wired directly to the device and then exit to the next device in the loop. The APS series will mount in a single gang box or the Potter P32-BB CAUTION surface mount back box. phis device is to be installed per the manufactures instructions in Operation accordance with the applicable NFPA standards,national and local fire and electrical codes.The Authority Having Jurisdiction(AM)should The APS-SA is activated by simply pulling the white "T" bar handle be consulted if there are any questions or local requirements. down.TheAPS-DAis activated by lifting the front cover and then pulling the white "T"bar. Once activated.the "T" bar cannot be reset without This device should be tested in accordance with NFPA standards. opening the front cover. Opening the front cover will also activate the manual pull station. Failure to follow the manufacturers recommendations could lead to the APS failing to report an alarm condition. It is the responsibility of the To reset the pull station, use the Potter WS-93 key and turn the lock to alarm installer to ensure this device is installed as intended.If there are open the front cover.Once the cover is open,push the white"T"bar into questions,contact Potter's Technical Support for clarification. the normal position and re-secure the (Font cover to the device. Setting the Address TheAPS series m List have the address set prior to installation ofthe manual pull station.This is accomplished using the handheld programmer or the SLC programmer on the fire alarm control panel(FACP).The address is stored on the module attached to the pull station and should he uniquely addressed.The device address should be recorded on the mounting plate of the pull station for future reference. Potter Electric Sigma I Company,LLC•St.Louis;MO 6 3042 USA•CUSt Service:866-956-121 1•Tech S upport:866-240-1870•Canada:888-882-1833•"-%%w.pottersignal.com PRINTED IN USA MKT 05406283-RE,'-AI PAGE I Of 2 04/13 (2,) POTTER APS_SA/APS_DA The Symbol of Protection ADDRESSABLE PULL STATION SINGLE/DUAL ACTION Pull Station Front View FIRE ALARM PULL DOWN 1 POTTER Pull Station Back View 0 h 0 NIJ i-' S+S ==NEXTDEVICE OM FACP OR PREVIOUS DEVICE FACTORY WIRED CONTACTS 0 0 PRINTED IN USA MKT k5406283-REV-A I PAGE 2 OF 2 04/13 @P0TTERo/V,a_"M/' DCM-4 The Symbol of Protection DUAL CONTACT MODULE Features • Single contact module with dual inputs �— Two(2)Class B and one(1)Class A input module • SLC Class A(Style 6,7)&Class B(Style 4) S- S. IDC wiring may be Class B(Style B)or Class A(Style D) a..ti.wW c.�.• ���� �•,�« All connections are power limited t� m �_� •>;� • Wiring For all connections is supervised •�"'=r N Terminals accept 14 to 22 AWG wire 27, zr .•- cr Mounts in 4"square box with terminals accessible • Temperature range of 32°F-120°F • Maximum loop current draw of 325 µA Note:This addressable module does not support 2-wire smoke detectors C&US LISTED �k S2930 7165-0328:0196 Producl includes a S year warranty Description 1 The Dual Contact Module,DCM-4 is used to supervise multiple All terminals are power limited and should be wired in accordance contact points with unique addresses from a single device.In addition, withthe requirements ofNFPA70(NEC)and NFPA72(National Fire the DCM-4 may be configured as a single contact utilizing Class A Alarm Code).Failure to follow the wiring diagrams in the following wiring methods. pages will cause the system to not operate as intended. For further The DCM-4 is fully supervised if wired in accordance with the wiring information,refer to the control panel installation instructions. diagrams below.Normally closed contact monitoring is not UL listed. For more information,refer to a compatible fire panel installation. The DCM-4 employs one red LED to indicate the status. In normal Operation and Programming Manual. condition,the LED flashes.When the contact is activated,the LED Setting the Address will turn on constantly.In case of open circuit,the LED will turn off. Each addressable module,smoke sensor,heat detector and If the conditions of two contacts are different from each other with combination sensor/detector must have the address set before two contacts supervising,the LED shall activate with higher priority connecting the device to the SLC loop.The address is set using the condition.The highest priority of contact condition is activated hand held device programmer or the addressing feature on the control condition of contact,the middle priority is open circuit,and the lowest panel. priority is normal condition. Before connecting a device to the SLC loop,take the following Since the system allows a maximum of 13 LEDs to activate constantly, precautions to prevent potential damage to SLC or device.Verify the if system already has 13 LEDs active on devices,DCM-4 will not turn following: on the LED and keep flashing even if the contacts of DCM-4 are in the active state. l. Power to the device is removed 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. Document discrepancies and notify appropriate personnel. A dedicated address number is configured per the DCM-4 module prior to connecting the module to SLC.loop.When DCM-4 is used for two contacts supervising,two addresses are assigned.When the first address number is assigned by address setting unit,the second address number shall be assigned automatically with adding one(1)to first address number.For example;if the first address number is assigned as "2",the second address number shall be assigned as"3"automatically. Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-240-1970•Tech Support:866-956-1211 •Canada:888-882-1833•www.pottersignal.com PRINTED IN USA MITT.48830008-REV A-3 PAGE I OF 2 04,E 13 P P OT T E RO A AOHM/ DCM-4 The Symbol of Protection DUAL CONTACT MODULE Installation Figure 1: Installation into the compatible electrical box Ab:�- 00, ° o Wiring Diagrams Figure 2:Wiring diagram in case of one contact supervising NOI FROM FACP OR CI PREVIOUS MODULE S+ Zl S- NO2 TO THE NEXT MODULE pggp0pqpq C2 LED Q Z2 SELECT STYLE 0 kni 0000 NOTE:END-OF-LINE RESISTOR IS NOT REQUIRED Figure 3:Wiring diagram in case of two contacts supervising(A'ormally-open Contact) NOl FROM FACP OR CI - PREVIOUSMODULE S+ Zl END-OF-LINE RESISTOR 5.1K OHM 112V S_ NO2 TO THE NEXT MODULE C2 SELECT STYLE Ii 0-000 LED O Z2 END-OF-LINE RESISTOR 5.1K OHM 1/2V Figure 4:Wiring diagram in case of two contacts supervising(Normally-closed contact)(Not UL/ULC Listed) ONLY ONE NORMALLY CLOSED CONTACT NO NOTE:END-OF-LINE RESISTOR IS NOT REQUIRED FROM FACP OR C I PREVIOUS MODULE 3+ ZI S_ NO2 TO THE NEXT MODULE PI C2 ONLY ONE NORMALLY CLOSED CONTACT SELECT STYLE B 0000 LED Q Z2 NOTE:END-OF-LINE RESISTOR IS NOT REQUIRED PRINTED IN USA -IKT.48830008-REV A-3 PAGE 2 OF 2 04n 3 PSA P, P0TTER0ArAC7-J4A*Y/' PHOTOELECTRIC SMOKE The Symbol of Protection SENSOR Featores • Low proli le,less than 2 inches with the base Wide selectable sensitivity range of 1.05 to 3.82%/foot • Sensor communicates sensitivity to control panel UL listed smoke calibration and sensitivity • Optional locking tab to prevent unwanted removal • Simple and accurate address setting\.vithout mechanical switches LEDs for 360°viewing C UL US LISTED S24776 7165-0328:0194 Producl includes a 5 year Irarranty Description Before connecting a device to the SLC loop,take the following The Photoelectric Smoke Sensor is a listed Analog Addressable smoke precautions to prevent potential damage to SLC or device.Verify the sensor compatible with any fire alarm control panel that has the Potter/ lollowing: Nohmi protocol.The PSA is a low profile smoke sensor with a wide I. Power to the device is removed sensitivity range.The sensor and base(not included)are made of a 2 Field wiring is correctly installed. durable plastic in an eggshell white to blend in with the ceiling. 3 Field wiring has no open or short circuits. The PSA has a sensitivity range of 1.05 to 3.82%per foot and is UL Document discrepancies and noti ly appropriate personnel. and cUL listed.The PSA may be configured for drift compensation and has built in dirty detector warning as well as.The PSA and Specifications the control panel communicate over a proven and robust digital connnunication path and the system analyzes the level of alarm at the Item PSA particular device.The total polling speed is less than live(5)seconds, Working voltage range 22.0 to 24.0 V well under the UL requirements. Standby current 325 µA The PSA has two Ll.'Ds that allow for 360'viewing.The sensor is Alarm indicator 2 LEDs compatible with any of the Potter/Nohmi bases and simply twists on- Alarm indicator current 1.2 mA D.C. The PSA is addressed using the hand held programmer or the control Alarm set-point range 1.05 to 3.82'No/ft /3.4 to 12.0 io/m panel addressing function. Installation temperature range 32 to 120°F/ 0 to 49°C Air Velocity Ratings Operating relative humidity 0%to 93%(Non-condensing) The PSA has an Open Area of Protection air velocity rating oft)to 300 range fleet per minute. Start-up time Max. 1 sec. Maximum number of 127 The system has a maximum of 13 LEDs that can be turned on addresses per loop simultaneously.If the system already has 13 LEDs on,the PSA will Maximum number of lighted 13 operate even though the LED will not illuminate. indicators in alarm per zone. Color Eggshell White Setting the Address Weight(without base) 84g(2.96oz) Each addressable module.smoke sensor,heal detector and Dimensions(without base) Height: 1.33 in(34mm) combination sensor/detector must have the address set before Diameter:4.0 inches(99nun) connecting the device to the SLC loop.The address is set using the hand held device programmer or the addressing fealure on the control I Approvals/Listings UL,ctlL,CSEM Panel. Potter Llectrie Signal Company,LLC•St.Louis,MO•Cust Service:866-240-1870•"tech Support 866-956-1211 •Canada:888-882-1833•www.pottersignal.com 11111111 PRINTED IN USA k1KT.48830015-REV C PAGE I OF 2 06/13 PSA e' P OTT ER* OHM/' PHOTOELECTRIC SMOKE The Symbol of Protection SENSOR Operation The PSA is an analog addressable sensor that uses one address on the Signaling Line Circuit(SLC)of a compatible fire alarm control panel.The unit communicates with the control panel as it is polled.The LEDs flash every time the unit is polled and they will latch steady if the unit is in an active status. The PSA is a proven design being in service throughout the world.The PSA with the AB-4 or AB-6 base has a low profile of less than two(2) inches to blend into the surrounding environment.The sensor includes an insect screen to prevent foreign objects from reaching the chamber and the entire iinil can he cleaned with a simple vacunm. Sensor Sensitivity The PSA and the compatible control panel work in tandem to keep the sensitivity consistent.As the sensor is installed over time.the sensor com- pensates for the dirt in the unit until it is out of range.At that time.the panel will indicate a dirty sensor.The sensor will then have to be cleaned or replaced. Anytime the PSA is being polled_the sensitivity may be viewed or printed from the control panel. Vote:As required by NFPA.do not install the sensors until all construction is complete and the work area has been thoroughly cleaned. lfthe sensors have been installed in a construction environment_they should be cleaned or replaced before the system is placed into service. Spacing The PSA is tJL/tJL,C listed with a recommended maximum spacing of 30 feet.Refer to NFPA 72 for specific infonnation regarding detector spacing,placement and special applications. Compatible Bases All bases will mount on a single gang.double gang_octagon.4"square or mud ring electrical box. Device Description AB-4 4"Standard Base AB-6 6"Standard Base AIB 6"base\vith an isolator module included.The base is pre-wired with a pluggablc jumper to the module. ARB 6"base with a dual relay module included.One relay is rated for 3 amps at 240 VAC/30 VDC and the second is rated for 2 amps at 240 VAC/30 VDC.The base is pre-wired with a pluggablc juniper to the module. ASB 6"base with sounder module included.Sound pattern is provided from external source.The base is pre-wired with a pluggable jumper into the module. PRINTED IN USA MKI 48830015-REV C PAGE 2 OF 2 06/13 P POTTER®A,AOHM/ TRM-4 The Symbol of Protection TWIN RELAY MODULE r = - Features • Two(2)Form C contacts Both contacts rated at 2 Amps at 24 V DC/0.5 Amps at 125 VAC Mounts in 4"or double gang box ~l _ Contacts operate simlutaneously 6���,•.,n,„,,,�,,, Power limited or non-power limited based on power source """._•mod" Maximum standby and alarm current,325 µA Status LED to indicate status NU 07 NO2 NCI of Not Wire terminal accessible with module mounted C UL US LISTED S2930 7165-0328:0196 Product includes a 5 year warranly Description The TRM-4 module is a two Form C relay contact that is programmed All terminals are power limited and should be wired in accordance to activate when mapped devices are activated.The two Form C relay withthe requirements ofNFPA70(NEC)and NFPA72(National Fire contacts activate simultaneously. Alarm Code).Failure to follow the wiring diagrams in the following TRM-4 employs one red LED to indicate the status.In normal pages will cause the system to not operate as intended. For further condition,the LED flashes.When the relay contact is activated,the information,refer to the control panel installation instructions. LED will turn on constantly. For more information refer Loa compatible control panel manual. The system has a maximum of 13 LEDs that can be activated simultaneously.If the system already has l3 LEDs on,the TRM-4 will operate even though the LED will not illuminate. Setting the Address Normally Open Normally Closed Each addressable module.smoke sensor,heat detector and Contact 1 Cl &N01 CI &NCI combination sensor/detector must have the address set before connecting the device to the SLC loop.The address is set using the Contact 2 Cl &NC2 C2&NC2 hand held device programmer or the addressing feature on the control Palle], Before connecting a device to the SLC loop,take the following precautions to prevent potential damage to SLC or device.Verify,the following: I. Power to the device is removed 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. Document discrepancies and notify appropriate personnel. Potter Electric Signal Coinpany,LLC•St.Louis,MO•C11St Service:866-240-1870•'Tech Support:866-956-1211 •Canada:888-882-1833•vww.pottersignal,coil PRINTED IN USA NIKT.M30005-REV C PAGE I OF 2 04/13 P POTT ER*A OHM/ TRM-4 The Symbol of Protection TWIN RELAY MODULE Installation Figure 1:installation into the compatible electrical box ®O O O e O e O 0 O o �°� o 0 Oa � coo m 0 0 0 Wiring Diagram Figure 2:Wiring diagram of TRM-4 From FACP or previous module r N01 Normally open 1 $LC LOOP I C1 Common I To the next module S+ Ic NCI Normally Closed 1 S- r NO2 Normally open 2 C2 Common 2 LED 0Ic NC2 Normally Closed 2 Before connecting an output device,connect the module to the SLC loop and reset it with the FACR This is necessary to ensure that the internal relay is unlatched.Connection of the module with this relay in the latched state(terminal between NO and CI,and NO2 and C2 are short)will activate the output device possibly causing damage. PRINTED IN USA N1KT.48830005-REV C PAGE 2 OF 2 04/13 @POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC UL, ULC,and FNIl Approved Sizes Available: 6"(150nnn),8"(200mm)and IO"(250trim) S Voltages Available: 24VAC 120VAC 12VDC(10.2 to 15.6)Polarized 24VDC(20.4 to 31.2)Polarized Service Use: Fire Alartn General Signaling w •� Burglar Alarm .! Environment: Indoor or outdoor use(See Note 1) -400 to I50OF(401 to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells-4 No. 18 AWG stranded wires & U-C �FM DC Bells-Terminal strip Finish: Red powder coating Optional: ModelBBK-I weathetproofbackbox Model BBX-1 deep weatherproof backbox These vibrating type bells are designed for use as fire,burglar or general Notes: signaling devices. They have low power consumption and high decibel I. Minimum dB ratings are calculated from integrated sound pressure ratings.The unit mounts on a standard 4"(1 Olmm)square electrical box measurements made at IJnderwriters Laboratories as specified in LIL for indoor use or on a model BBK-I weatherproof backbox or BBX-1 Standard 464. UL temperature range is-30'to 150OF(-340 to 66°C). deep weatherproof backbox for outdoor applications. Weatherproof' 2. Typical dB ratings are calculated Front measurements made with a backbox model BBK-1,Stock No. 1500001. conventional Sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to MBA DC bells. Size inches Voltage Model Stock Current Typical dB at Minimum dB at (mm) Number Number (Max.) 10 ft.(3m)(2) 10 ft.(3m)(1) 6(150) 12VDC MBA-6-12 1750070 .12A 85 76 8(200) 12VDC MBA-8-12 1750080 .12A 90 77 10(250) 12VDC MBA-10-12 1750060 .12A 92 78 6(150) 24VDC MBA-6-24 1750100 .06A 87 77 8(200) 24VDC MBA-8-24 1750110 .06A 91 79 10(250) 24VDC MBA-10-24 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .17A 91 78 8(200) 24VAC PBA248 1808024* .17A 94 77 10(250) 24VAC PBA2410 1810024* .17A 94 78 6(150) 120VAC PBA1206 1806120* ,05A 92 83 8(200) 120VAC It PBA1208 1 1808120* .05A 99 84 10(250) 120VAC I PBA 12010 1 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. *Does not have ULC listing. A WAR N I N G In outdoor or wet installations,bell must be mounted with weatherproof backbox,BBK-I or BBX-1.Stvidard electrical boxes will not provide a weatherproof enclosure.If the bell and/or assembly is exposed to moisture,it may tail or create an electrical hazard. Potter Electric Signal Company, L,LC • St. Louis, MO. Phone: 866-572-3005/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA NIFG45400776-BEVY-1 PAGE I OF 01i13 (E,) POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC Bells Dimensions Inches(mm) Wiring(rear view) Fig. I Fig.3 A.C. BELLS WHITE(IN) WHITE(OUT) I FRUM CONTROL (2001 6 I I PANEL OR II\U, I I PRECEDING BELL 13L%CK ', III.AIKIIM?1 CAUTION: WHEN ELECTRICAL SUPERVISION IS RFQU I RED USE IN AN'D OU L LEADS AS SHOWN (68) DWGa 776-1 NOTES! I.\YH EN USING AC UELLS.T ERK1INxrr rmi I EXTRA WIRE SEPARATELY AFTER LAST BELL 2 FND-OF-LINE RESISTOR IS NOT R LOU[RED ON AC BELLS nx,,=rrw Weatherproof Backbox Dimensions Inches(mm) Fig.2 FACP Box has one threaded 1/2"conduit entrance 0 o i O — aa,a' I To Next fib 117, 'lab' � Device or � End-or-Line L Resistor I Li 1 5iS, (h61 —I (a11 a 1/4" (I08) Installation DWGr 776-2 1. The bell shall be installed in accordance with NFPA 13,72,or local AHT.The top of the device shall be no less than 90"AFF and not less than 6"below the ceiling. O 2. Remove the gong. 3. Connect wiring(see Fig.3). 4. Mount bell mechanism to backbox(bell mechanism must be mounted with the striker pointing down). <11 ° 5. Reinstall the gong(be sure that the gong positioning pin,in the mechanism housing,is in the hole in the gong). o 6. Test all bells for proper operation and observe that they can asp-I � be heard where required(bells must be heard in all areas as designated by the authority having jurisdiction). AWARNING Failure to install striker down will prevent bell from operating. PRINTED IN USA MFG 95400776-REV Y-1 PAGE 2 OF 2 01/13 I 7788F/7744 F Series = "AESlIntelliNet CUHH'ORATION Fui Aiaim Munftuuri}l Wireless Fire Alarm ommunicators for Features—All models I • UL Listed commercial fire alarm appli- AES-Int'PIIiNet cations. J— Meets NFPA 72 requirements liDirect reporting to AES receiver across IntelliNet wireless mesh net- work • Each Subscriber acts as transmit- ter/receiver/repeater • Simple and fast activation on network • On board status LEDs for easy set up • 8 programmable zone inputs—7788F • 4 programmable zone inputs and 4 reverse polarity inputs—7744F • Easy programming via AES handheld programmer or PC • Rugged metal housing ideal for any commercial fire alarm application Models 7788F/7744F-ULP with IntelliPro Fire also includes Model 77ssF IntelliPro Fire transmits full alarm data LISTED from virtually any fire alarm panel dig- ital communicator Advanced Wireless Alarm Monitoring Alarm format support for Contact ID, The AES-IntelliNet mesh radio network offers unmatched reliability and Pulse, or Bosch Modem Ile or Modem speed in delivering wireless alarm signals to a central station without third IIla2 party fees or reliance on networks owned by companies outside the security Easy installation in AES subscriber and fire alarm industry. AES-7788F/7744F Series Smart Subscriber Operates in applications with or with- Transceivers provide the wireless communication link between the fire out a phone line alarm panel and the central station receiver. The 7788F/7744F Series is ideal for most commercial fire alarm applications. Each 7788F/7744F Series Subscriber is housed in a full sized, red, locked, steel cabinet and supports �=— a range of alarm panel inputs including EOL fire, EOL supervised, and direct voltage from the panel (non-fire applications). Supervised Operation AES Smart Subscribers offer fully supervised operation that includes moni- toring of operating power (both primary AC power and battery backup) and the connection to the radio network. Each Subscriber"checks in" with the ; AES central station receiver at least once every 24 hours. The supervision Wireless mesh networking is an innovative technology adopted by check in time can be set for as often as once per minute and, because the many industries with applications central station owns the wireless network, there is no additional cost for air that need to communicate data over time to transmit supervisory signals. a large geographic area with a high level of reliability at a low total cost Full Data Reporting from Alarm Panel Digital Dialer of ownership Models 7788F-ULP and 7744F-ULP come equipped with an IntelliPro Fire The advanced design and 2-way Full Data Module (AES-7794) which enables reporting of full alarm data communications capability provides captured from the fire alarm panel's digital communicator. IntelliPro Fire easy installation, expansion, andmanagement when compared to alter- supports most alarm communication formats including Contact ID, Pulse, as native communication methods, both well as Bosch Modem Ile and Modem Illa2. wired and wireless. 7788F/7744F Series -4AES'Intel#Nes Ci?I;PC+I t A f ION j For Nntrr i Mor,-toi Technical Specifications How to Order 7788F/7744F Series Subscribers Model Description Dimensions Antenna Cut/Communication 7744F 4 Zone Fire Alarm • 13.25"H x 8.5"W x 4.3"D Trouble Output Subscriber with (34crn H x 2 1.5crn W x 11 urn D) Form C relay; fail secure; rated for 24 4 reverse polarity inputs Weight VDC 1A resistive Approx. 7 pounds(3.2 kilograms), Reset Button 7744F-ULP 7744F Fire Alarm excludes battery. • Located on main circuit board. Subscriber with IntelliPro Radio Frequency Operating Temperature Fire full data module • Standard Frequency Range: • 0°to 50' C (32'to 122°F) 7788F 8 Zone Fire Alarm 450-470MHz(others available) Storage Temperature Subscriber Output Power-2 Watts • -1W to 60o C (14° to 140°F) (others available) 7788F-ULP 7788F Fire Alarm Relative Humidity Subscriber with IntelliPro Antenna • 0 to 85% RHC, Non Condensing Fire full data module • Included 2.5 db tamper resistant antenna mounts on enclosure AES-7794 IntelliPro Fire • Multiple remote antenna options Input/Output Connections available Optional Accessories • RJ11 connection to AES subscriber for p Power Input module data and power 7041 E Subscriber Handheld • 16.5VAC, 40VA(transformer not RJ11 connector for Handheld i Programmer included) Programmer/PC programming Backup Battery RJ31X Telco connections-T and R 7794 IntelliPro Fire Full Data • Will charge 12V battery up to 7.5 AH. both in and out via terminal strip and Module Requires 12VDC 7.5 AH battery for RJ45 UL 864. Alarm Panel digital communicator ---� s�_ Alarm Signal Inputs(subscriber) T and R both in and out via terminal l E`U ® Art • 7788F—8 individually programmable strip and RJ45 tititwuy�rr' AMlRIC� NFPA zones Trouble output: Form C relay detects if • 7744F-4 individually programmable Subscriber is off the network zones and 4 reverse polarity inputs Alarm Formats UL Standards • Support for Contact ID and Pulse • UL 864 Edition 9—Standard for formats as well as Modem Ile and Control Units and Accessories for Fire Modem IIla2 converted to CID Alarm Systems Size • UL 365—Standard for Police Station . 2.8 x 5.0 inches (7.1 cm x 12.7cm) Connected Burglar Alarm Units and Power Requirements Systems • 12 VDC nominal-primary and backup • UL 1681 —Standard for Central power provided by the AES Station Burglar Alarm Units 7788F/7744F or other Subscriber AES-Inrclll"ler' s tha;inqusiry le;Ider in clellvt ';'s ,,; iii,. , and sec.lr,ty induslly In cn'nrnsidai,co porstr-,.ypyr; :r, broad line of 1u;r:.agui,ii have(aAied signlflcarit rFlvenue.cnrii nuluc._clot._:antl u_I� us� Ali�, �;e.t I i, ;r n„ . dards of reliability required for the irr-r,and nd: :.ln; na')1tikxurt<;y:-;ir;rn;r are cr2ploycd at hundreds of thousm lcis of locations m cv,=l I'101 cut;ntrio; AESl IntelliNe CORPORATION Ft,,Annn Mf,Ti ltorinq For more information ` Call 800-AES-NETS (800-237-6387) AES Corporation 1 285 Newbury Street Peabody, MA 01960 USA Copyright 2011 AES corporation AES-IntelliNet is a registered trademark Tel.+1 978-535-7310; Fax+1 978-535-7313 I Email info@aes-intellinet.com I of AES Corporation Web www.aes-intellinet.com _ r 708F-7744F/917111 R3 CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address: Permit#:882 Parcel#:0235820 Valuation:2000.00 OWNER APPLICANT CONTRACTOR Name:Stoddard International Name:Alarmtech Inc Name:Alarmtech Inc Address: 18660 58TH AVE NE Address:P.O.Box 186 Address:P.O.Box 186 City,State Zip:Arlington,WA 98223 City,State Zip:Mountlake Terrace,WA 98043 City,State Zip:Mountlake Terrace,WA 98043 Phone: Phone:425-931-7066 Phone:425-931-7066 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2012 STORIES: 1 CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and co led i of Arlington#310 Signaler Print Name Date Released By Da c CONDITIONS Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 1/14/2016 Fire Alarm Fee $95.30 1/14/2016 Fire Review Fee $100.00 Total Due: S195.30 Total Payment: $0.00 Balance Due: $195.30 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon 64 FIRE ALARM 10 PERMIT APPLICATION Department of Community& Economic Development City of Arlington •18204 59th Ave NE •WA 98223• Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY THREE(3)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION.INCLUDE ELECTRICAL PLANS WHERE APPLICABLE.ALSO,INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS, (POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) New Fire Alarm ❑ Fire Alarm Alteration/Addition Project Address: C-C) A� Ne Parcel ID#: Number of Zones/Panels I Building Area(Sq Ft): Valuation: goon Owner: Phone Number: Address: City State: Zip Code: Contact Person: Phone Number: Cell Phone E-mail: Address City: State: Zip Code Contractor: LPhone Number. Lj� Address: ® t—�` �� 1�b City: ��^T lo`k "Stater (' C Zip Code: c� `l Contractor's License Number: A c, ryy�=,)� 9 64I N Expiration Electrical Contractor: Phone Number: Address City: State: Zip Code: Contractor's License Number: Expiration I hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described property will be accordance with the laws, rules and regulations of the State of Washington. The applicant will be responsible for providing a method of safely accessing roof for inspection A final inspection and approval shall be obtained when the re-roofing is complete. Appicants Signature Date Print Applicants Name FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received WEB Form—130 Page 1 of 1 7/10CJY 51*11 Fire Alarm System Legend PO BOX 186 MOUNTIAKE TERRACE,WA 98043 Symbol Device Description Manufacturer Part NO. Mnt . Box Mnt . Height Qt . (425)-775-4208 AES Digital Alarm Radio Transmitter Potter 7788F Supplied As Required 1 (425)-775-5410 Manual Pull Station Potter APS-SA Single Gan 48"To Operable 1 O Photo Smoke Detector Potter PSA AB-6 As Required 1 O S rinkler Water Flow Switch By Others By Others By Others By Others 1 PO BOX 186 MOUNTLAKE TERRACE,WA 98043 O C4Z zoEB Sprinkler Tamper B Others B Others B Others B Others 1 s>-��s-4 C4z5)1-775-5410 tl� Dual Contact Input Module Potter DCM-4 4 Square Box As Required 1 w a 0 Weatherproof Bell Potter MBA-1024 BBK-1 As Required 1 End of Line Resistor As Required As Re uired N/A N/A N/A FRc� F;cc A,%—rm C—�rol t�W <1 -tov nl/ As <q rod l z 0 "s FIRE ALARM CABLING LEGEND 1-3/4 CODE CABLE LINETYPE CIRCUIT TYPE MANUFACTURER PART NO. CABLE TYPE A INITIATING DEVICE CIRCUIT BELDEN 5320UL 18/2 FPLR 0 g -- --- ----- NOTIFICATION APPLIANCE CIRCUIT BELDEN 5120UL 1412 FPLR �\ m C AUXILIARY DEVICE CIRCUIT BELDEN 5120UL 14/2 FPLR p -- -- -- REMOTE ANNUNCIATOR CIRCUIT BELDEN 5320UL,512OUL 1812 FPLR,1412 FPLR P 1-1 1_2 ------------ EOLNACI n �.I D r v co CV _ CV (� � Q � C t L � Q E OFFICE COPY � o � Q CITY OF ARLINGTON BUILDING DEPARTMENT -0 00 -6 APPROVED 10 Lo DATIL//�!rlv py /1� O c (n CO co NO CHANGES AUTHORIZED CD iu a- UNLESS APPROVED BY THE BUILDING INSPECTOR 0 ~ P O W 0 2 LL. I DRAWNBY: Jesse Houfek CHEMED81 RICK MoCurdY PLAN NORTH PLOT DATE 12/29/15 A PROJECT NUMBER: SCALE=118"=1'0" 0 4' 8' 12' 16' Received JAN182016 FA- 1 DRAWING ONLY TO SCALE IF PLO EDOAT 24 X 36" lll'.DCTNUMBER: Stoddard International Fire Alarm System Submittals OFFICE PY Site Address: 18660 58th Ave NE Arlington, WA 98223 CITY OF ARLINGTON BUILDING DEPARTMENT APPROVED DATE NO CHANGES AUTHORIZED UNLESS APPROVED BY THB BUILDING INSPECTOR PO Box 186 Mountlake Terrace, WA 98043 Voice (425)775-4208 Fax (425)775-5410 Received JAN 13 2016 �ko R--- ZOTD/IWJT ►►'IO YTIO lr"3Rl mgsd ovlla.uu* C3VOfigqA '�1....��r.�rr..r.r.rTrAQ O"MOHTUA"WAMOOn BHT YO 03VOR9aA 883JW FlOT039awl Qwlojl r� X P POTT'TJO P i 00 • Fire Alarm Control Panel Features -- • 30 Analog Addressable Points.Any combination of detectors/ modules • 3.5 Amp Power Supply.Expandable to 315 amps • 2 NAC circuits rated at 3 amps maximum,expandable to 188. • Built-in UL Listed IP Communicator • Built-in email event notification and report capability. • Optional Dual Line Digital Alarm Communicator • System wide synchronization of Potter/AMSECO,Gentex, Cooper/Wheelock.and System Sensor signals. • No twisted or shielded wiring required. • Cabinet will accommodate up to 18AH batteries.Panel will charge Lip to 55AH. • Capable of Class A or Class B wiring configurations • Built-in NPPA 72 compliant smoke detector sensitivity,test • Dead-front cabinet design • 1000 Event History Buffer Product includes a 5 Potter/Nohmi Protocol Features year warranly • Less than 4 second polling time S7'5 7165-0328:0195 • LED's visible from 360' • Adjustable Smoke Detector Sensitivity • Adjustable Heat Detector Temperature • High Temperature Heat Detector as fixed temp • Drift Compensation • Maintenance Alerts • Day/Night Mode Description The P100 is a small analog/addressable fire alarm control panel with a The entire system,including the SLC,NACs and P-Link may be total of 30 points.The points may be any combination of smoke sensors, converted with a C A-6075 Class A module.The entire system is heat detectors or modules.This panel has a 3.5 amp power supply that is programmed using a Windows based computer software and requires distributed across two Notification Appliance Circuits(NACs). the use of a software programming sofrivare key. The NAC circuits are rated at a maximum of 3 Amps each.All of The P 100 can communicate to a monitoring station using the optional the outputs may be configured for notification or auxiliary power.In UL listed UD-1000 traditional two line alarm communicator or the addition,each NAC can be programmed for strobe synchronization and built-in UL listed IP communicator.The UD-1000 connects to the main utilizes Quadrasync for strobe synchronization across circuits of various board and has two phone line jacks provided.The 1P communicator brands, uses a RJ-45 connection and when connected to the internet may The cabinet will hold two 12 volt,8 amp/hour batteries or two 12 volt, be programmed to E-mail system status,history reports or the 18 amp/hour batteries.The system when fully loaded will charge 55 configuration file.The panel may be updated remotely using the amp/hour batteries.Anything larger than 18 amp/hour will require an UD-1000. external battery cabinet the SSU-00050. The panel has the Potter P-Link connection for expansion with remote annunciators,intelligent power supplies and other optional modules. The P-Link will support 31 accessories in any combination.The RA-6075 is a 2 x 16 LCD annunciator.The RA-6500 offers a larger 4 x 40 line LCD display that allows points and descriptions to be shown simultaneously. Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • www.potiersignal.com �! FwJr 48830033-REV A PAGE 1 OF 4 08/12 P POTTFIZ PI 00 P�US� Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to thirty(30)addressable devices or modules in any combination.The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description ` PSA Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PSHA Combination Analog Photo Electric Smoke/I-leat Detector-a smoke detector with a listed obscuration of 1.02 to 3.83 percent r obscuration and a fixed temperature 135'Fahrenheit heat detector FHA Analog Fixed Temperature I feat Detector that is selectable from 135'F to 185°F RI IA Analog Rate or Rise Heat Detector that has a fixed temperature selection from 135°F and 174°F and also will alarm if the temperature increase 12-15°F in one minute I AB-6 6"round base that is mounted to an electrical box and wired I'or connection of one of the above sensors i AB-4 4"round base that may be mounted to an electrical box and wired for connection to the above sensors AIB lsolater base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop ARB Addressable Relay Base that contains two relays controlled by the SLC.One relay is rated at 8 amps at 240 VAC/30VDC and the other is rated at 2 amps 240 VAC/30 VDC ASB Addressable Sounder Base that contains and addressable sounder module that may be configured for local,group and all call.The { sounder follows the pattern sent to the device. Modules Device Description { MC II Miniature Contact Module provides a small foot print contact module f'or mountin-inside an enclosure,typically used to monitor 1 a pull station r - SCM-4 Single Contact Module is a standard contact module with an LED that mounts into a 4"square electrical box.The contact moni- tors normally open contacts and the LED will provide an indication when the device has activated. i L DCM-4 i Dual Contact Module is a device that can monitor two distinct inputs with a single device or in a Class A mode.The DCM-4 mounts into a 4"square electrical box and has a cover plate with an LED as a status indication. 1 — - - - TRM-4 Twin Relay Module provides two firm C relays that simultaneously active when the module is triggered by the control panel iEach relay is rated for 2 amps at 24VDC or 0.5 amps at 125 VAC. VIOM-4 Monitored Output Module is a power switching module that monitors the circuit that is controlled by the control panel. CIZM-4 Conventional Input Zone Module is used to connect conventional smoke detectors to the system that receive their power from the I module.This module is like a conventional zone on the SLC. SCI Short Circuit Isolater interrupts a short on the SLC and prevents the short from affecting protected devices on the loop.These or — — 1 Ilte AM are required in Class A.Style 7 installations. Potter Electric Signal Cotnpant;LLC • St Louis,MO (2)POTTER yr 800-325-3936 • www.pottcrsianal.com L4 48830033-REV A RAGE 2 OF 4 08/12 P POT- Pi 00 Plus J Fire Alarm Control Panel SLC Features P-Link The Potter/Nohmi protocol is a digital protocol with a proven design The P100 has a proprietary communication protocol that communicates for reliability and noise immunity.The system does not require special through a RS-485 connection to field devices.Up to thirty-one cable or conductors for connection of the Signaling Line Circuit as (31)devices may be connected to a single P-Link connection.The long as the cable is compliant with NEPA 70 and NFPA 72.The system P-Link includes the communication terminals and regulated 24 VDC allows for Class A or Class B installations as well as"T-Taps." connection for the field devices.The field devices may be any of the 'The total polling time for the protocol is about four(4)seconds which following: allows two polling cycles in the ANSI/UL 864 requirement of alarms RA-6075—2 x 16 LCD annunciator with a key pad in a locked metal reporting in less than ten seconds. Each loop is capable of 127 points enclosure. with the exception of the P 100 and P200. RA-6500—4 x 40 LCD annunciator with a key pad in a locked metal Sensor Features enclosure The sensors through the fire alarm control panel provide a real PSN-1000(E)— 10 amp,remote intelligent power supply with 6 NACs, time status as to the condition of the system.The smoke detector 2 1/Os and a P-Link repeater sensitivity,heat detector temperature level and drift compensation CA-6075—Class A convertor that converts the SLC,NACs and P-Link as all programmable options.The system also allows for a day/night connection mode where the panel automatically adjusts the sensitivity depending LJD-1000—UL listed,Dual line telephone alarm communicator on the time of day.To assist in the reduction of false alarms,the smoke detectors also have a maintenance warning that sends a trouble signal Ethernet/I.P. Connection when a detector is dirty to the point that it can no longer maintain the "The P 100 is shipped standard with an Ethernet connection.This programmed sensitivity. connection is the programming port and may be connected to a building Programming Wide Area Network(WAN)or Local Area Network(LAN).Once connected to the internet.the panel may be selectively programmed to The programming of the 1`100 is accomplished through a Windows E-mail alarm conditions,trouble conditions.supervisory conditions, based software program.The program is intuitive in drag and drop test,Event History and detector status.An e-mail may he sent to the of points into zones for easy system configuration.There is a total of panel and the panel will e-mail the event history,detector status, 99 zones that may be configured.The software requires the use of a configuration file or server status to an authorized Email account. software programming key to communicate to the P100.The system utilizes a standard Ethernet cable for connection between the computer In addition,the Ethernet connection is UL listed as an I.P. and the control panel. communicator.The I.P.communicator is listed to report to the UL listed Sur-Gard LLL I.P.receiver."The L.P.communicator replaces the traditional User Interface less reliable alarm communicator transmitter that utilized telephone lines.The I.P.communicator is an active method of connection and The fire alarm control panel has a 4 x 40 LCD display to provide communication to the monitoring station. information to the system status.The keypad has navigation keys to allow manipulation of the Menu on board the panel.The panel is shipped standard with the following LEDs: • AC Power—Green • Alarm—Red • Earth Fault—Amber • Supervisory-Amber • Silenced-Amber • Trouble-Amber The common buttons include a Silence,Reset.Acknowledge and Drill. All of the buttons are accessible once the locked door is opened. Potter Electric Signal Company,LLC St.Louis,MO i np 800-325-3936 • www.potiorsignal.com �•!��� FW 98830033-REV A PAGE 3 Or 4 08,12 P POTTFIZ PI 00 f�uS� Fire Alarm Control Panel Specifications p TOP . . DEPTH=3.75" Electrical Specs: AC Mains ° 3.0 Amps(cr 120 VAC 50/60 HZ DOOR=16.07" 2.0 Amps n 240 VAC 50/60 HZ BACKBOX=15.77" DEPTH=3.84- I Battery 130 n1A Standby • 220mAAlalm • • 3.5 Amps power For NACs,I/0.and P-Link • 3 Amps per NAC,regulated © N 0O • Battery Charger range 8-55 All °o v oQ • Battery Charger voltage 27.3 VDC • P-Link maximum current of I Amp Cabinet • 16 gauge cold rolled steel with removable LEFTSIDE RIGHTSIDE locked door • Dimensions—16"W x 17H x 3 /s"D BOTTOM DWG#593-1 • Dead front to cover all electronics • Lexan viewing window Temperature and Humidity This fire alarm control is listed and approved for operation in all indoor application with temperature range fluctuations of 32°to 120°(0°C to 49°C) with a maximum humidity of 93%non-condensing.The ideal temperature is 77°F +/-l0°F(25°C+1-5°C), Standards 'rile P100 series fire alarm control panel complies with the following standards and codes. • NFPA 13,70 and 72 • ANSI/UL 964 o Local(L),Remote Station(IRS),Central Station(CS),Propriety(PPU),Auxiliary(AUX) o Type of Service:Automatic(A),Manual(M),Water flow(WF)Sprinkler Supervisory(SS) o Type of Signaling: Digital Alarm Communicator(DAC).Marcli Time(March),Non Coded(NC),Reverse Polarity(Rev Pol),Other Technologies(OT) • IBC 2000,2003,2006,2009,2012 Potter Electric Signal Company,LLC • St Louis,MO ©POTTER 800-325-3936 • www.poUcrsignal com F*6 48830033-REV A PAGE 4 OF 08/12 (E) POTTER APS-SA/APS-DA The Symbol of Protection ADDRESSABLE PULL STATION SINGLE/DUAL ACTION Features: • Durable Die Cast Manual Pull Station ' r Matching FireAlartn Control Panel Key • Mounts in Single Gang Box • Single or Dual Action • Compatible with all PFC-6000,PFC-8000.and P-Series Panels PULL 00 N Rated Voltage 22 to 24 VDC Standby Current Draw 0.325 mA Alarm Current Draw 0.325 mA Temperature Range 321F to 120°F(0°C to 49°C) � �jtT�R Relative Humidity Range 0 to 93%(non-condensing) r c �L us LISTED APS-SA Addressable Pull Station Single Action 1430810 APS-DA Addressable Pull Station Dual Action 1430811 Description ADA Compliance The APS-SA and APS-DA addressable manual pull stations are non- 'file APS series is required to be mounted between 42"(106.7 cm)and coded that provide an addressable point to a Potter alarm system.The 48" (121.9 cm) 1Pom the finished floor. The maximum side reach is APS series has terminals that allow the signaling line circuit(SLC)to be allowed to be 54 inches(137.2 cut). wired directly to the device and then exit to the nest device in the loop. The APS series will mount in a single gang box or the Potter P32-13B CAUTION surface mount back box. Vss''�� This device is to be installed per the manufactures instructions in Operation accordance with[he applicable NFPA standards,national and local fire and electrical codes.The Authority Having Jurisdiction(AHJ)should be consulted if there are any questions or local requirements. The APS-SA is activated by simply pulling the white "T" bar handle down.TheAPS-DA is activated by lifting the front cover and then pulliog the white "T" bar. Once activated, the "T" bar cannot be reset without This device should be tested in accordance vvidt NFPA standards. opening the front cover. Opening the front cover will also activate the manual pull station. Failure to follow the manufacturers recommendations could lead to the APS failing to report an alarm condition.It is the responsibility of the To reset the pull station, use the Potter WS-93 key° and turn the lock to alarm installer to ensure this device is installed as intended. If there are open the front cover.Once the cover is open.push the white"'f"bar into questions,contact Potter's'Technical Support for clarification. the normal position and re-secure the from cover to[he device. Setting the Add ress TheAPS series m usthave the address set prior to installation ofthe manual pull station.This is accomplished using the handheld programmer or the SIX programmer on the fire alarm control panel(FACP).The address is stored on the module attached to the pull station and should be uniquely addressed.The device address should be recorded on the mounting plate of the pull station for future reference. Potter Electric Signal Company,LLC•St.Louis.M063042 USA•CustService:866-956-1211-Tech Support:866-240-1870•Canada:888-882-1833•wv%-\tcpottersignal.com PRINTED IN USA %IKT.r5406283-RUALA I PAGE I OF 2 04/13 (DPOTTER APS-SA/APS-DA The Symbol of Protection ADDRESSABLE PULL STATION SINGLE/DUAL ACTION Pull Station Front View FIRE ALARM PULL DOWN 1 POTTER Pull Station Back View 0 0 OM FACP OR PREVIOUS DEVICE " NEXT DEVICE i C� FACTORY WIRED CONTACTS 0 0 PRINTED IN USA 1vIKT.#5406283-REV-A I PAGE 2 OF 2 04/13 (E) P0TTER*Ar,a_"M/. DCM-4 The Symbol of Protection DUAL CONTACT MODULE Features • Single contact module with dual inputs -- 0 Two(2)Class B and one(1)Class A input module • SEC Class A(Style 6,7)&Class B(Style 4) s. 1DC wiring may be Class B(Style B)or Class A(Style D) All connections are power limited ' Wiring for all connections is supervised • ��-— Y Terminals accept 14 to 22 AWG wire ZZ eZ :' Mounts in 4"square box with terminals accessible ITemperature range of 32°F-120°F • Maximum loop current draw of 325 µA Note:This addressable module does not support 2-wire smoke detectors C UL US LISTED S2930 7165-0328:0196 Producl includes a 5 year irar•ranly Description The Dual Contact Module,DCM-4 is used to Supervise multiple All terminals are power limited and should be wired in accordance contact points with unique addresses from asingle device.in addition, withthe requirements ofNFPA70(NEC)and N FPA72(National Fire the DCM-4 may be configured as a single contact utilizing Class A Alarm Code).Failure to follow the wiring diagrams in the following wiring methods. pages will cause the system to not operate as intended. For fiirther information,refer to the control panel installation instructions. The DCM-4 is fully supervised if wired in accordance with the�-wing diagrams below.Normally closed contact monitoring is not UL listed. For more information,refer to a compatible fire panel installation. The DCM-4 employs one red LED to indicate the status. In normal Operation and Programming Manual. condition,the LED flashes.When the contact is activated,the LED Setting the Address will turn on constantly.In case of open circuit,the LED will turn off. Each addressable module,smoke sensor,heat detector and If the conditions of two contacts are different from each other with combination sensor/detector must have the address set before two contacts supervising,the LED shall activate with higher priority connecting the device to the SEC loop.The address is set using the condition.The highest priority of contact condition is activated hand held device programmer or the addressing feature on the control condition of contact,the middle priority is open circuit,and the lowest panel. priority is normal condition. Before connecting a device to the SEC loop,take the following Since the system allows a maximum of 13 LEDs to activate constantly, precautions to prevent potential damage to SEC or device.Verify,the if system already has 13 LEDs active on devices,DCM-4 will not turn following: on the LED and keep flashing even if the contacts of DCM-4 are in the active state. l. Power to the device is removed 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. Document discrepancies and notify appropriate personnel. A dedicated address number is configured per the DCM-4 module prior to connecting the module to SLC loop.When DCM-4 is used for two contacts supervising,two addresses are assigned.When the first address number is assigned by address setting unit,the second address number shall be assigned automatically with adding one(I)to first address number.For example;i f the first address number is assigned as "2",the second address number shall be assigned as"3"automatically. Potter Electric Signal Company,LLC•St Louis,MO•Cust Service:866-240-1870•Tech Support:866-956-1211 •Canada.888-882-1833•www.pottersignal.com PRINTED IN USA MKT 48830008-REV A-3 PAGE I OF 2 04/13 P ' P OT T E RO A OHM/5 DCM-4 The Symbol of Protection DUAL CONTACT MODULE Installation Figure 1:Installation into the compatible electrical box o o n a 0 O �a b ° ° 0o 0 0 o � Wiring Diagrams Figure 2:Wiring diagram in case of one contact supervising NO] FROM FACP OR C I PREVIOUS MODULE S+ ZI S- NO2 TO THE NEXT MODULE OppOpQpO C2 SELECT STYLE D 0000 LED O Z2 NOTE:END-OF-LINE RESISTOR 1S NOT REQUIRED Figure 3:Wiring diagram in case of two contacts supervising(Nornlolly-open contact) NOI FROM FACP OR C] PREVIOUS MODULE S� ZI _ END-OF-LINE RESISTOR 5.1K OHM]/2V g- NO2 TO THE NEXT MODULE pp C2 0000 SELECTSTYLEIi 0000 LED O Z2 CND-OF-LINE RESISTOR 5,IKOHM 1/2V Figure d:Wiring diagram in case of two contacts supervising(A%ornially-closed conlocl)(Not UL/ULC Listed) ONLY ONE NORMALLY CLOSED CONTACT NOI NOTE:END-OF-LING RESISTOR IS NOT REQUIRED FROM FACP OR C I PREVIOUS MODULE S+ I S- NO2 TO THE NEXT MODULE I C2 ONLY ONE NORMALLY CLOSED CONTACT 0088 LED O Z2 NOTE:END-OF-LINE RESISTOR IS NOT REQUIRED SELECT STYLE Ii OO PRINTED IN USA MKT.#8830008-REV A-3 PAGE 2 OF 2 04/I3 PSA np PoTTFR � PHOTOELECTRIC SMOKE The Symbol of Protection SENSOR FeaInres • Low profs le, less than 2 inches with the base • Wide selectable sensitivity range of 1.05 to 3.82%/foot Sensor communicates sensitivity to control panel • UL listed smoke calibration and sensitivity • Optional locking tab to prevent unwanted removal • Simple and accurate address setting without mechanical switches • LEDs for 360'viewing C UL US LISTED S24776 7165-0328:0194 Product includes o 5 year urarranly Description 13elbre connecting a device to the SLC loop.take the following The Photoelectric Smoke Sensor is a listed Analog Addressahle smoke precautions to prevent potential damage to SLC or device.Verify the sensor compatible with any fire alarm control panel that has the Potter' following: Nohmi protocol.The PSA is a low profile smoke sensor with a wide I power to the device is removed sensitivih range.The sensor and base(not included)are made of a 2 Meld vviring is correctly installed. durable plastic in an eggshell white to blend in with the ceiling. 3. Field wiring has no open or short circuits. The PSA has a sensitivity range of 1.05 to 3.82%per foot and is UL Document discrepancies and notify appropriate personnel. and OR,listed.The PSA may be confi-ured for drift compensation and has built in dirty detector warning as well as.The PSA and Specifications the control panel communicate over a proven and robust digital communication path and the system analyzes the level of alarm at the Item PSA particular device.The total polling speed is less than live(5)seconds, Working voltage range 22.0 to 24.0 V well under the UL requirements. Standby current 325 µA The PSA has two LEDs that allow for 360'viewing.The sensor is Alarm indicator 2 LEDs compatible with any of the Potter/Nohmi bases and simply twists on Alarm indicator current 1.2 mA D.C. The PSA is addressed using the hand held programmer or the control Alarm set-point range 1.05 to 3.82%/ft /3.4 to 12.0%/m panel addressing lunction. Installation temperature range 32 to 120°F/ 0 to 49°C Air Velocity Ratings Operating relative humidity 0%to 93%(N oil-condensing) The PSA has an Open Area of Protection air velocity rating of 0 to 300 range legit per minute. Start-up time Max. 1 sec. Maximum number of 127 The sys[em has a maximum of 13 LEDs that can be turned on addresses per loop simultaneously. Ifthe system already has 13 LEDs on,the PSA will Maximum number of lighted 13 operate even though [he LED will not illuminate. indicators in alarm per zone. Color Eggshell White Setting the Address Weight(Without base) 84g(2.96oz) Each addressable module.smoke sensor.heal detector and Dimensions(without base) Height: 1.33 in(34mm) combination sensor/detector must have the address set before Diameter:4.0 inches(99111ni) connecting the device to[he SLC loop.The address is set using the hand held device programmer or the addressing feature on the control Approvals/Listings LA.,cUL.,CSFM panel. Potter Electric Signal Company,LLC•St Louis,MO•CnSt Service:866-240-1870•Tech Support:866-956-1211 •Canada:888-882-1833•wwmpottersignal.com PRINTED IN USA %II 1 #8830015-REV C PAGE I OF 2 06r13 P P0TTER*jVa-"M/' PHOTOELE�CSTRIC SMOKE The Symbol of Protection SENSOR Operation The PSA is an analog addressable sensor that uses one address on the Signaling Line Circuit(SLC)of a compatible fire alarm control panel.The unit communicates with the control panel as it is polled.The LEDs flash every time the unit is polled and they will latch steady if the unit is in an active status. The PSA is a proven design being in service throughout the world.The PSA with the AB-4 or AB-6 base has a low profile of less than two(2) inches to blend into the surrounding environment.The sensor includes an insect screen to prevent foreign objects from reaching the chamber and the entire unit can be cleaned with a Simple vacuum. Sensor Sensitivity The PSA and the compatible control panel work in tandem to keep the sensitivity consistent.As the sensor is installed over time,the sensor com- pensates for the dirt in the unit until it is out of range.At that time,the panel will indicate a dirty sensor.The sensor will then have to be cleaned or replaced. Anytime the PSA is being polled.the sensitivity may be viewed or printed from the control panel. Note:As required by NFPA.do not install the sensors until all construction is complete and the work area has been thoroughly cleaned.If the sensors have been installed in a construction environment.they should be cleaned or replaced before the system is placed into service. Spacing The PSA is ULA-JLC listed with a recommended maximum spacing of 30 feet.Refer to NFPA 72 for specific information regarding detector spacing,placement and special applications. Compatible Bases All bases will mount on a single gang.double gang,octagon.4"square or mud ring electrical box. Device Description AB-4 4"Standard Base AB-6 6"Standard Base AIB 6"base with an isolator module included.The base is pre-wired with a plug-gable jwnper to the module. ARB 6"base with a dual relav module included.One relay is rated for 8 amps at 240 VAC/30 VDC and the second is rated for 2 amps at 240 VAC/30 VDC.The base is pre-wired with a pluggablejLimper to the module. ASB 6"base with sounder module included.Sound pattern is provided from external source.The base is pre-wired with a pluggablejumper into the module. PRINTED IN USA MKT.48830015-REV C PAGE 2 OF 2 06/13 i P POTTERS A OHM/ TRM-4 The Symbol of Protection TWIN RELAY MODULE Features • Two(2)Form C contacts 1 Both contacts rated at 2 Amps at 24 VDC/0.5 Amps at 125 VAC l Mounts in 4"or double gang box �� _ s• Contacts operate simlutaneouSly Power limited or non-power limited based on power source " - mt:°.":.�• m Maximum standby and alarm current,325 µA Status LED to indicate status 1 _ NO2 It i NO2 NO CI NOI • Wire terminal accessible with module mounted i� C&I LISTED S2930 7165-0328:0196 Product includes a 5 year•urarrarnly Description The TRM-4 module is a two Form C relay contact that is programmed All terminals are power limited and should be wired in accordance to activate when mapped devices are activated.The two Form C relay withthe requirements ofNFPA70(NEC)and NFPA 72(National Fire contacts activate simultaneously. Alarm Code).Failure to follow the wiring diagrams in the followving TRM-4 employs one red LED to indicate the status.In normal pages will cause the system to not operate as intended. For further condition,the LED flashes.When the relay contact is activated,the information,refer to the control panel installation instructions. LED will turn on constantly. For more information refer Loa compatible control panel manual. The system has a maximum of 13 LEDs that can be activated simultaneously.If the system already has 13 LEDs on,the TRM-4 will operate even though the LED will not illuminate. Setting the Address Normally Open Normally Closed Each addressable module,smoke sensor,heat detector and combination sensor/detector must have the address set before Contact I C I &No I AC I &NC I connecting the device to the SLC loop.The address is set using the Contact 2 CI &NC2 C2&NC2 hand held device programmer or the addressing feature on the control panel. Before connecting a device to the SLC loop,take the followwing precautions to prevent potential damage to SLC or device.Verify the following: I. Power to the device is removed 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. Document discrepancies and notify appropriate personnel. Potter Electric Signal Company,LLC•St.Louis,MO•CLIS[Service:866-240-1870•Tech Support:866-956-1211•Canada:888-882-1833•wwwvpottersignal corn PRINTED IN USA MKT.48830005-REV C PAGE I OF 2 04/13 P P oT T E R4 A OHM/- TRM-4 The Symbol of Protection TWIN RELAY MODULE Installation Figure l:Installation into the compatible electrical box �O O O o O � a 0 O O �o ° b ° O O O O o 0 0 0 0 Wiring Diagram Figure 2:Wiring diagram of TRM-4 From FACP or previous module r NOl Normally open t $LC LOOP C1 10 Common t To the next module S+ NC1 jo Normally Closed 1 S— NO2 Normally open 2 C2 10 Common 2 LED 0 NC2 jo Normally Closed 2 NOTICE Before connecting an output device,connect the module to the SLC loop and reset it with the FACP,This is necessary to ensure that the internal relay is unlatched.Connection of the module with this relay in the latched state(tenninal between NO and C I,and NO2 and C2 are short)will activate the output device possibly causing damage. PRINTED IN USA MKT.#8830005-REV C PAGE 2 OF 2 04/13 I (E) POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC LT, ULC,and FN7 Approved Sires Available: 6"(150nnn),8"(200mm)and 10"(250mm) Voltages Available: 24VAC 4 120VAC 12VDC(10.2 to 15.6)Polarized 24VDC(20.4 to 31.2)Polarized Service Use: Fire Alarm 't General Signaling Burglar Alarm Environment: Indoor or outdoor use(See Note 1) -400 to 150OF(400 to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells-4 No. 18 AWG stranded wires u�C wF DC Bells-Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep vveathetproof backbox These vibrating type bells are designed for use as fire,burglar or general Notes: signaling devices. They have low power consumption and high decibel I. Minimum dB ratings are calculated from integrated sound pressure ratings.The unit mounts on a standard 4"(101nnm)square electrical box measurements made at Underwriters Laboratories as specified in tit, for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 Standard 464. UL temperature range is-30'to 150T(-34'to 66'Q. deep%veathetproof backbox for outdoor applications. Weatherproof' 2. Typical dB ratings are calculated from measurements made with a backbox model BBK-1,Stock No. 1500001. conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to MBA DC bells. Size inches Voltage Model Stock Current Typical dB at Minimum dB at (mul) Number Number (Max.) 10 ft.(3iu)(2) 10 ft.(3m)(1) 6(150) 12VDC MBA-6-12 1750070 .12A 85 76 8(200) 12VDC MBA-8-12 1750080 .12A 90 77 10(250) 12VDC MBA-10-12 1750060 .12A 92 78 6(150) 24VDC MBA-6-24 1750100 .06A 87 77 8(200) 24VDC MBA-8-24 1750110 .06A 91 79 10(250) 24VDC MBA-10-24 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .17A 91 78 8(200) 24VAC PBA248 1808024* .17A 94 77 10(250) 24VAC PBA2410 1810024* .17A 94 78 6(150) 120VAC PBA1206 1806120* .05A 92 83 8(200) 120VAC PBA1208 1808120* .05A 99 84 10(250) 120VAC PBA 12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. *Does not have ULC listing. A WAR N I N G In outdoor or wet installations,bell must be mounted with weatherproof backbox,BBK-I or BBX-1.Standard electrical boxes will not provide a weatherproof enclosure.If the bell and/or assembly is exposed to moisture,it may fail or create an electrical hazard. Potter Electric Signal Company, L,LC • St. Louis, MO. Phone: 866-572-3005/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG.45400776-REV Y-I PAGE I OF 2 01,13 (E,) POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC Bells Dimensions Inches(mm) Wiring(rear view) Fig. l Fig.3 A.C. BELLS VAHIreI N)aS.. N%HITF(' OUT) t(200) 6• IPRI I vN eL OIROI(150) raeceDINGDeLL U L\(KILN) ULACK1/11111 _Tr_ CAUTICYS: WHEN FILEC'TRIC:\L SUPER\'ISI ON IS REQUIRED USE IN AND OU r LEA DS ASS[[OWN y.11l ?11/1(i (6�) M16,7761 NOTES: I WHEN USING AC UEL LS.TCRNIINATE EACHEXTRA\\IRr,SEPARATELY:\ETER LAST DELL. =END-DE-LINE RESISTOR IS NOT Rr.QIUIRED ON.\(•UrLLS nxr.ryl Weatherproof Backbox Dimensions Inches(mm) Fig.2 EACP Box has one threaded 1/2"conduit entrance I i 0 saa^ O — "s To Next 11461 Ifi6J 112T Device or find-or--Line Resistor I 4' �I I c IS,6) 41 t 104i Installation 1. The bell shall be installed in accordance with NFPA 13,72,or local AHJ.The top of the device shall be no less than 90"AFF and not less than 6"below the ceiling. 0 2. Remove the gong. t p o a 3. Connect wiring(see Fig.3). e 4. Mount bell mechanism to backbox(bell mechanism must be mounted witli the striker pointing down). ° 5. Reinstall the gong(be sure that the gong positioning pin,in the mechanism housing,is in the hole in the gong). 0 6. Test all bells for proper operation and observe that they can eux-i be heard where required(bells must be heard in all areas as designated by the authority having jurisdiction). AWARNING Failure to install striker down will prevent bell from operating. PRINTED tN USA MFG 45400776-REV Y-I PAGE 2 OF 2 01,13 7788F/7744F Series AESlIntelliNet COHpngATIQN Frx Alarm AAnndollr,g Wireless Fire Alarm coommunicators for Features—All models • UL Listed commercial fire alarm appli- AES-/n IliNet cations. • Meets NFPA 72 requirements • Direct reporting to AES receiver across IntelliNet wireless mesh net- work T- • Each Subscriber acts as transmit- ter/receiver/repeater • Simple and fast activation on network • On board status LEDs for easy set up I'. E • 8 programmable zone inputs—7788F • 4 programmable zone inputs and 4 reverse polarity inputs—7744F • Easy programming via AES handheld programmer or PC • Rugged metal housing ideal for any commercial fire alarm application eau Models 7788F/77"F-ULP with IntelliPro Fire also includes Model 7788F LISTEDIntelliPro Fire transmits full alarm data from virtually any fire alarm panel dig- ital communicator Advanced Wireless Alarm Monitoring Alarm format support for Contact ID, The AES-IntelliNet mesh radio network offers unmatched reliability and Pulse, or Bosch Modem Ile or Modem speed in delivering wireless alarm signals to a central station without third llla2 party fees or reliance on networks owned by companies outside the security Easy installation in AES subscriber and fire alarm industry.AES-7788F/7744F Series Smart Subscriber Operates in applications with or with- Transceivers provide the wireless communication link between the fire out a phone line alarm panel and the central station receiver. The 7788F/7744F Series is ideal for most commercial fire alarm applications. Each 7788F/7744F Series Subscriber is housed in a full sized, red, locked, steel cabinet and supports --_ - a range of alarm panel inputs including EOL fire, EOL supervised, and direct voltage from the panel (non-fire applications). Supervised Operation AES Smart Subscribers offer fully supervised operation that includes moni- toring of operating power (both primary AC power and battery backup) and j the connection to the radio network. Each Subscriber"checks in" with the AES central station receiver at least once every 24 hours. The supervision Wireless mesh networking is an check in time can be set for as often as once per minute and, because the innovative technology adopted by many industries with applications central station owns the wireless network, there is no additional cost for air that need to communicate data over time to transmit supervisory signals. a large geographic area with a high level of reliability at a low total cost Full Data Reporting from Alarm Panel Digital Dialer of ownership. Models 7788F-ULP and 7744F-ULP come equipped with an IntelliPro Fire The advanced design and 2-way Full Data Module (AES-7794) which enables reporting of full alarm data communications capability provides captured from the fire alarm panel's digital communicator. IntelliPro Fire easy installation, expansion, andmanagement when compared to alter- supports most alarm communication formats including Contact ID, Pulse, as native communication methods,both well as Bosch Modem Ile and Modem Illa2. P wired and wireless. 7788F/7744F Series -- ,AES telfiNe CORPONArION [Vio points Technical Specifications How to Order 7788F/7744F Series Subscribers Model Description Dimensions Antenna Cut I Communication 7744F 4 Zone Fire Alarm • 13.25"H x 8.5"W x 4.3"D Trouble Output (34cm H x 21 5cm W x 11 cm D) Form C relay; fail secure; rated for 24 Subscriber with 4 reverse polarity inputs Weight VDC 1A resistive • Approx. 7 pounds(3.2 kilograms), Reset Button 7744F-ULP 7744F Fire Alarm excludes battery. • Located on main circuit board. Subscriber with IntelliPro Radio Frequency Operating Temperature Fire full data module • Standard Frequency Range: • 0°to 50o C (32° to 122°F) 7788F 8 Zone Fire Alarm 450-470MHz(others available) Storage Temperature Subscriber • Output Power-2 Watts • -10°to 60o C (14o to 140°F) (others available) Relative Humidity 7788F-ULP 7788F Fire Alarm Subscriber with IntelliPro Antenna • 0 to 85% RHC, Non Condensing Fire full data module • Included 2.5 db tamper resistant antenna mounts on enclosure AES-7794 IntelliPro Fire • Multiple remote antenna options Input I Output Connections available Optional Accessories • RJ11 connection to AES subscriber for p Power Input module data and power 7041E Subscriber Handheld • 16.5VAC, 40VA(transformer not RJ11 connector for Handheld Programmer included) Programmer/PC programming Backup Battery RJ31X Telco connections-T and R 7794 IntelliPro Fire Full Data • Will charge 12V battery up to 7.5 AH. both in and out via terminal strip and Module Requires 12VDC 7.5 AH battery for RJ45 UL 864. Alarm Panel digital communicator _ Alarm Signal Inputs (subscriber) T and R both in and out via terminal LIS 11r=117788F—8 individually programmable strip and RJ45 ® — �`1NtR` ► ...,� ewNfRKi zones Trouble output: Form C relay detects if • 7744F-4 individually programmable Subscriber is off the network zones and 4 reverse polarity inputs Alarm Formats UL Standards • Support for Contact ID and Pulse • UL 864 Edition 9—Standard for formats as well as Modem Ile and Control Units and Accessories for Fire Modem Illa2 converted to CID Alarm Systems Size • UL 365—Standard for Police Station . 2.8 x 5.0 inches (7,1cm x 12.7cm) Connected Burglar Alarm Units and Power Requirements Systems 12 VDC nominal-primary and backup • UL 1681 —Standard for Central power provided by the AES Station Burglar Alarm Units 7788F/7744F or other Subscriber AES-IlltelliNet-is the industry leadhr in delivl-w'i�.j Iii�flh r}u��lUy r!usir�s., ncr.t!n�twclha ro iit;: lu and sFcurity industry in Comrnr)rclal broad line of product,and advanced nelvofk ntanagenel?�to��ls t.lse'.n:nts.l_ � I�i�r,llll,rci tie't'Jerk, have,gr3lned slynlficant. '%dv;.Ai,t_g'vv NOI mf-eln y ire hIl i dards of reliability required for ih�flrt anti sl:cunk, ndu:;try r=.�;_-Inir.IliNnt alarm I,lonilorlr7c;sy_,icmr:� are dE'ployed at hundreds of thausnnws,of locai.ions In 1"V4,71150 Ca,t!niri«s. AES(IntelliNe 0ORPORATION Fa AWnr1 Mrnntnnng For more information Call 800-AES-NETS (800-237-6387) AES Corporation 1285 Newbury Street 1 Peabody, MA 01960 USA 11 Copyright 2011 AES Corporation AES-InlelliNet is a registered trademark Tel. +1 978-535-7310', Fax+1 978-535-7313 Email info@aes-intellinet.com IA ofAES Corporation Web www.aes-intellinet.com �� 71eaF-7744Fi9/7111 R3 ti Permit#: 882 Permit Date: 01/14/16 Permit Type: FIRE ALARM Project Name: Stoddard International Applicant Name: Alarmtech Inc Applicant Address: P.O. Box 186 Applicant, City, State, Zip: Mountlake Terrace,WA 98043 Contact: Jesse Holfak Phone: 425-931-7066 Email: Scope of Work: New Fire Alarm Valuation: 2000.00 Square Feet: 0 Number of Stories: 1 Construction Type: Occupancy Group: ID Code: Permit Issued: 03/10/2016 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 0235820 18660 58TH AVE NE Stoddard International Contractors Contractor Primary Contact Phone Address Contractor Type License License# Alarmtech Inc Jesse Holfak 425-931-7066 P.O.Box 186 CONSTRUCTION ALARMTECH ALARMI*964NR CONTRACTOR INC Plan Reviews Date Review Type Description Assigned To Review Status 01/14/2016 FIRE ALARM BUILDING Fees Fee Description Notes Amount Fire Alarm Plan Review Fee $95.30 Fire System Plan Review Table 4-1 $100.00 Total $195.30 Attached Letters Date Letter Description O1/14/2016 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 03/10/2016 Gregory Traulsen. 58663124 cc $195.30 Outstanding Balance $0.00 Uploaded Files Date File Name 09/26/2016 1860419-882 Approved Plans.pdf 09/26/2016 1860420-882 Specs.pdf 03/10/2016 1513643-3-10-16 Issued Permit.pdf 01/21/2016 1434407-Application.pdf c� o o , m r cn Ir,ED r I J o T cn 3 0 m F x < i ➢ r '� o m (n n i S' fD o m 3 � o m (D D —0 o � A W o v m o m a in o o' `CD z z o F cn E o 0 — n _ SI .T—J �1 I5 s 0 � ::3 Frim C _.N o p W W o a M A m D v C' ICJ � (D A_ D CD /1♦ o o n I -I v �' � D Z c• C N � � � n -I 'V. A Z rn C O �0 m 3 m G-) > ca W W W R7 O O m I X. cn cn W y tY /n o IF D d x o y A CR O m m (D - D 3 r < n O M II I .I II i _— RI I � I I II I I D m O � r - Z z K ED Cy -73 O cg OO S G tGo a m � �o y 1< p� O Z QI O"1ym yv X K, a P zSYMBOL REVISION DAZE m� Stoddard International 'a zo IN Nc 18660 58th Ave Ne Arlington, WA 98223 v MN ra X SHEETTITLE: Floor Plan and Riser Diagram O o 00 0x �� 0 w w �