Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
128 N DUNHAM AVE_BLD6567_2026
i RESIDENTIAL MECHANICAL APPLICATION • Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping. Please fill out all pages of this application and include all information. Type of Permit: ❑ New Installation Addition/Alteration/Repair ❑ Gas Piping 128 No Dunham Avenue 3500 Property Address: Project Valuation: Lot#: Parcel ID No.: Preferred Contact: ❑ Owner 0 Contractor Project Description: 80-80 Furnace Change Out Pat & Kim Andrew 2533815598 Owner Name: Home No.: Email Address: patjandrew@gmail.com Cell No.: Mailing Address: City: State: Zip:128 No Dunham Ave Arlington WA .98223 Contractor Name: Home Comfort Alliance Office No.: 4255639149 Email Address: homecomfortalliance.com Cell No.: Mailing Address: 3409 Everett Ave city: Everett State: WA Zip: 98201 L&I Contractor License Number: Expiration Date: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Gas Piping Information ❑ Not Applicable ❑ CSST ❑ Brass ❑ Other Proposed Piping Material: ❑ Black Steel ❑ Galvanized Steel Proposed Piping Size: ❑ 1/2" ❑ s/s" 713/4" ❑ 1" ❑ 11/2 ❑ 2" Distance from Meter to furthest Appliance: Total BTU's of all Appliances: Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan review per Table 4-8 may be required for certain permits) Type of Fixture No. of Cost per Unit Subtotal Model No. Units Additional Plan Review fees x $75.00 = Air Conditioning Unit<_ 100 Btu h x $ 15.00 = Air Conditioning Unit> 100 Btu h x $25.00 = Air Conditioning Unit> 500 Btu/hp x $50.00 = Air Handling Units x $ 15.00 = Base Mechanical Fee 1 x $25.00 = $25.00 7 Boiler<100Btu h>3h x $ 15.00 = REV03.2022 Page 1 of 3 Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan review per Table 4-8 may be required for certain permits) Boiler>1 million Btu/h<50hp x $25.00 = Boiler>1.5 million Btu/h<50hp x $50.00 = Boiler>100Btu h 3-15h x $ 15.00 = Boiler>500Btu h 15-30hp x $25.00 = Commercial Hoods-Type I x $25.00 = Commercial Hoods-Type II x $50.00 = Diffusers x $ 15.00 = Dryer Ducting x $ 15.00 = Ductwork(drawings required x $25.00 = Evaporative Coolers x $ 15.00 = Exhaust/Ventilation Fans x $ 15.00 = Fireplace/Insert/Stove x $ 15.00 = Forced Air Heat<_100 Btu h 1 x $ 15.00 = 15.00 Forced Air Heat>100 Btu h x $25.00 = Gas Clothes Dryer x $ 15.00 = Gas Fired Air Conditioning Unit<_ 100 Btu h x $ 15.00 = Gas Fired Air Conditioning Unit> 100 Btu h x $25.00 = Gas Fired Air Conditioning Unit> 500 Btu/hp x $50.00 = Gas Pipin <_5 units x $ 15.00 = Gas Piping for each additional unit > 5 x $2.00 = Heat Exchangers x $ 15.00 = Heat Pump-Condensing Unit x $25.00 = Hot Water Heat Coils x $ 15.00 = Miscellaneous Appliance-regulated by x $ 15.00 mechanical code,not otherwise specified Package Units<_ 100 Btu > 100 Btu x $25.00 $50.00 = Range/Cook top-Gas Fired x $ 15.00 = Refrigeration Unit<_100Btu h x $ 15.00 = Refrigeration Unit>100Btu h x $25.00 = Refrigeration.Unit>500Btu h x $50.00 = Re-inspection fee x $75.00 = Residential Range Hood x $ 15.00 = Unit Heaters<_ 100 Btu/h x $ 15.00 = Unit Heaters>100 Btu/h x $25.00 = Variable Air Volume Boxes (part of Air x $ 10.00 Conditioning System) Wall Heaters-Gas Fired x $25.00 = Water Heater-Gas Fired x $25.00 = Permit Fee Inspection Fee $75.00 Processing/Technology Fee $25.00 Total 140.00 I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above described property will be in accordance with the laws,rules and regulation of the State of Washington. Signature Print Name Date REV2.2024 Page 2 of 3 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY 0 SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated REV2.2024 Page 3 of 3 RESIDENTIAL MECHANICAL APPLICATION • Community and Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223 • Phone (360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping. Please fill out all pages of this application and include all information. Type of Permit: ❑ New Installation Addition/Alteration/Repair ❑ Gas Piping 128 No Dunham Avenue 3500 Property Address: Project Valuation: Lot#: Parcel ID No.: Preferred Contact: ❑ Owner O Contractor Project Description: 80-80 Furnace Change Out Pat & Kim Andrew 2533815598 Owner Name: Home No.: Email Address: patjandrew@gmail.com gmall.com Cell No.: Mailing Address: City: State: Zip:128 No Dunham Ave Arlington WA .98223 Contractor Name: Home Comfort Alliance Office No.: 4255639149 Email Address: homecomfortalliance.com Cell No.: Mailing Address: 3409 Everett Ave city. Everett State: WA Zip: 98201 L&I Contractor License Number: Expiration Date: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Gas Piping Information ❑ Not Applicable ❑ CSST ❑ Brass ❑ Other Proposed Piping Material: ❑ Black Steel ❑ Galvanized Steel Proposed Piping Size: ❑ 1/2" ❑ s/s" 713/4" ❑ 1" ❑ 11/2" ❑ 2" Distance from Meter to furthest Appliance: Total BTU's of all Appliances: Residential mechanical permits will be assessed a base fee,fee per unit,and inspection fee (plan review per Table 4-8 may be required for certainpermits) Type of Fixture No.of Cost per Unit Subtotal Model No. Units Additional Plan Review fees x $75.00 = Air Conditioning Unit<_ 100 Btu h x $ 15.00 = Air Conditioning Unit> 100 Btu h x $25.00 = Air Conditioning Unit> 500 Btu/hp x $50.00 = Air Handling Units x $ 15.00 = Base Mechanical Fee 1 x $25.00 = $ 25.00 Boiler<10013tu h >3h x $ 15.00 = REV03.2022 Page 1 of 3 Residential mechanical permits will be assessed a base fee,fee per unit,and inspection fee (plan review per Table 4-8 may be required for certain permits) - Boiler>1 million Btu/h<50hp x $25.00 = Boiler>1.5 million Btu/h<50hp x $50.00 = Boiler>100Btu h 3-15h x $15.00 = Boiler>500Btu h 15-30hp x $25.00 = Commercial Hoods-Type I x $25.00 = Commercial Hoods-Type II x $50.00 = Diffusers x $15.00 = Dry er Ducting x $15.00 = Ductwork(drawings required) x $25.00 = Evaporative Coolers x $15.00 = Exhaust Ventilation Fans x $15.00 = Fireplace/Insert/Stove x $15.00- = Forced Air Heat<_100 Btu h 1 x $15.00 = 15.00 Forced Air Heat>100 Btu h x $25.00 = Gas Clothes Dryer x $ 15.00 = Gas Fired Air Conditioning Unit:5 100 Btu h x $15.00 = Gas Fired Air Conditioning Unit> 100 Btu h x $25.00 = Gas Fired Air Conditioning Unit>500 Btu/hp x $50.00 = Gas Pi in 5 5 units x $15.00 = Gas Piping for each additional unit >5 x $2.00 = Heat Exchangers x $15.00 = Heat Pump-Condensing Unit x $25.00 = Hot Water Heat Coils x $15.00 = Miscellaneous Appliance-regulated by $15.00 mechanical code,not otherwise specified x = Package Units:5 100 Btu > 100 Btu x $25.00 $50.00 = Range/Cook top-Gas Fired x $15.00 = Refrigeration Unit 5100Btu h x $15.00 = Refrigeration Unit>100Btu h x $25.00 = Refrigeration.Unit>500Btu h x $50.00 = Re-inspection fee x $75.00 = Residential Range Hood x $15.00 = Unit Heaters:5 100 Btu h x $15.00 = Unit Heaters>100 Btu h x $25.00 = Variable Air Volume Boxes(part of Air $10.00 Conditioning System) x = Wall Heaters-Gas Fired x $25.00 = Water Heater-Gas Fired x $25.00 = Permit Fee Inspection Fee $75.00 Processing/Technology Fee $25.00 Total 140.00 I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above de cribed perty will be in accordance with the laws,rules and regulation of the State of Washington. ec - �/ G Z5 ZS- Signature Print Name D to REV2.2024 Page 2 of 3 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY 0 SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE:Any interior pressure regulators must be indicated REV2.2024 Page 3 of 3 C-TIN' OFARLINGTON 18204 59di Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 B UILDING PERMTT 128 N DUNHAM AVE Permit#:6567 PERMIT EXPIRES 180 DAYS ATTER Parcel#:00378800500300 DATE OF ISSUANCE. Scope of Work:Furnace Valuation:3500.00 OWNER APPLICANT CONTRACTOR GARD 1UNIBERLY M Home Comfort Alliance Home Comfort Alliance 128 N DUNHANI AVE 3409 Everett Ave 3409 Everett Ave ARLINGTON,WA 98223-1308 Everett Wa 98201 Everett,WA 98201 253-381-5598 425-563-9172 LIC:003 537 354 F-\?:09/30/2025 LIC:1101VIECCA785BD EXP:01/04/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL MECHANICAL. CODE YEAR: 2021 STORIES: 2 CONST.TYPE: VB DWELLING UNITS: OCC GROUP: R-3;Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a penal for,or approval of,any violation of flus Code or any other ordnance or order of the City,of any state or federal law,or of any order,proclamation,&widance advice or decision of the Governor of thus State,To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of tune when such construction is prohibited or restricted by any slate or federal law,or order,proclamation,guidance advice or decision of the Governor of this Statc,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance 01'executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor, The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED N VIOLATION OF THE LABOR CODE OF THE STATE OF WASHNGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID, IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/1RC 110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101, 07/22J2025 Applicant.Signature Date Building Official Date CONDITIONS Adhere to the approved equipment,Permit shall be onsite for inspection.Call for final inspection. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or convnumity.The property owner shall be responsible for obtaining all necessary permits and approvals from(lie relevant authorities before commencing construction.The property owner shall ensure that the construction project.complies with an applicable design review requirements. THIS PERMIT AUT14ORI7-ES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRNATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 08/13/2025 Processing/Technology $25.00 08/13/2025 Inspection $75.00 08113/2025 Forced Air Heat s 100 BTU/h $15.00 0 811 3/2 02 5 Mechanical Base $25.00 08/13/2025 Credit Card SeNce $4.20 Total Due: $144.20 Total Payment: $144,20 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pin for nest day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the folloNiing information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail 58SBOB/58SB1 B Comfort 80, 80%AFUE, Single-Stage, Multi 18-Speed ECM, Carrier- Non-Condensing Gas Furnaces 2- E_ Turn to the experts Product Data PERFORMANCE ®®®� Single Stage gas valve ®®®� Multi 18-Speed,constant torque(MCT)ECM blower motor QuieTechTM noise reduction system ®O ®®®® Microprocessor based control center ® ®®®® Adjustable heating air temperature rise Adjustable cooling airflow • Enhanced diagnostics with easy to read 3 digit display for faults and ® status V®®9 Stores fault codes during power outages • Power HeatTM Igniter • Draft safeguard switch designed to ensure proper furnace venting • Inner door for tighter sealing INSTALLATION FLEXIBILITY o • 4-way Multipoise furnace, 13 vent applications s • On-board NFC antenna makes setup a tap away when using the Q Carrier service technician app A190411 • HYBRID HEAT®Dual Fuel System compatible Representative drawing only.Some product models may vary. • All models are chimney friendly when used with accessory vent kit • Select sizes approved for twinning,refer to accessory kit listing APPLICATIONS This furnace is not designed for use in mobile homes, trailers, or • Compact design-only 33-1/3 in.(847 nun)tall recreational vehicles. Such use could result in property damage and/or • Propane convertible with gas conversion accessory death. • Convenient Air Purifier and Humidifier connections The 58SBOB/58SB1B ComfortTM Series 4-way Multipoise Gas Furnaces CERTIFICATION feature Carrier's QuieTechTM noise reduction system for incredibly quiet . Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air induced draft operation. Applications are easy with 4-way multipoise leakage less than 1.4%at 0.5 in.w.c.when tested in accordance with design, through-the-furnace downflow venting, 13 different venting options, and designed for easy service access.An inner blower door is ASHRAE standard 193 provided for tighter sealing in sensitive applications. Improved • Residential installations eligible for consumer financing through the serviceability with the 3 digit status display and NFC enabled board Retail Credit Program allowing setup via the service tech app.The 58SBOB/58SB1B furnaces are approved for use with natural or propane gas,and the 58SB1B-Low NOx units are designed for California installations and can be installed in air quality management districts with a 40 ng/J NOx emissions limit. E iGH t•¢rasutt„�Br i IS09001, r Quality Comfort , CERTIFIED. S E R I E S Use of Me AH1U Certified TM Mark indicates a tuanufactu=r's participation in the program.For verification of certification for individual products. go to w .ahridiractoryrng A200123 58SBOB/58SB1 B:Product Data DIMENSIONAL DATA 26 116 [663.61 D C 9 SECTION 2-i 5 SCALE 3:16 1130.50.51 1 I116 F[51.61 NOTES: ® 1.Doors may vary by model. t I1/1e 2.Two additional 7/8-in.(22 mm)diameter holes are located in the top plate. 113.51 3.Minimum return-air openings at furnace,based on metal duct.If flex duct is used, see flex duct manufacturer's recommendations or equivalent diameters. c a.For 800 CFM-16-in.(406 mm)round or 141/2 x 12-in.(368 x 305 mm)rectangle. b.For 1200 CFM-20-in.S08 mm)round or 141/2 x 191/2-in.(368 x 495 mm)rectangle. c.For 1600 CFM-22-in.(559 mm)round or 141/2 x 221/16-in.(368 x 560 mm)rectangle. I.Return air above 1800 CFM may require one of the following configurations: TOP VIEW 07/8 2 sides,1 side and a bottom or bottom only for return air.See Air Delivery table in this 22 15116 122.21 document for specific use to allow for sufficient airflow to the furnace.. I582.61 ACCESSORY 121 /�I^� 1 15/16 1577.81 22 1116 3 15/is I�J [/9.2] .7I 3 7116 A 21 5/8 [313.11 [150 (549.31 5 0. AIR FLOW 5 1/8 0 19 I501.61 [1/0.31 � I118.51 1181.71 WTLEi 8 7/16 118 i/8 /13/I6 0112 21.2] 1122.2] I 112.71 7 13/16 [213.51 1 2.21 i� JUNCTION BO% TXEAMOSTAi WIRE ENTRY 9 17/76 ACCESSORY 9 9/16 N III [197.a]1245.41 LOCATION 12/3.31 1 - �1 3/1 [250.7] III.S] 71 i/76 __GAS TRTrr 1290.7 6112 I u-u 27 3/1 7/e -_-_-_-_-_-_ 21 3/1 1 2.7] Q31 3/1 [104.71 [22.21 [701.71 THERMOSTAT WIRE EXiRY IN.5] ALTERNATE TRY 29 9/16 JUNCTION 00% [750.71 LOCAi ION GAS EN 33 1// -'1 718 11 ACCESSORY 1 172e 159116 2 I 657/B i (1337/31 ACCESSORY . 122.21 '-'---- I �ACCESSORY 1B0TN SIDESI Ile..-_-_-_-_-_ k-_-_-_-_-__,I N5-21 BOTTOM 6 1/8 NNGCi OUTS F 22 1/16 I [549.5]BOTTGM INLET [I55.71 D 3/d VENTING 65 PLACCSI I5601 180TN SIDESI 125.1] 28 3I8 007TON RFTURN (19,11 SIDE IXIET 1 1// 26 1/16 [31.81 1721.21 i9 MI DTX 1662.01 1136.9] 26 7/16 [671.51 NOTE:ALL DIMENSIONS IN INCH(MM) U.S.ECCN: Not Subject to Regulation(N.S.R.) sons9<xev.- A210785 Dimensions A B C D VENT Unit Size TOP AND BOTTOM CONNECTION SHIP WT.LB. CABINET WIDTH OUTLET WIDTH BOTTOM FLUE INLET WIDTH SIZE (KG) COLLAR 045M14--12 14-3/16(360) 12-9/16(319) 9-5/16(237) 12-11/16(322) 4(102) 108(49) 045M17- 14 17-1/2(445) 15-7/8(403) 11-9/16(294) 16(406) 4(102) 121 (55) 070M14- 12 14-3/16(360) 12-9/16(319) 9-5/16(237) 12-11/16(322) 4(102) 114(52) 070M17- 12 17-1/2(445) 15-7/8(403) 11-9/16(294) 16(406) 4(102) 124(56) 070M17- 16 17-1/2(445) 15-7/8(403) 11-9/16(294) 16(406) 4(102) 127(58) 070M21--16 21 (533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 139.5(63) 090M17- 14 17-1/2(445) 15-7/8(403) 11-9/16(294) 16(406) 4(102) 133(60) 090M21--16 21 (533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 140.5(64) 090M21--20 21 (533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 147(67) 090M24--20 24-1/2(622) 22-7/8(581) 15-1/16(383) 23(584) 4(102) 150(68) 110M21--20 21 (533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 150(68) 110M24--20 24-1/2(622) 22-7/8(581) 15-1/16(383) 23(584) 4(102) 165(75) 135M24--20 24-1/2(622) 22-7/8(581) 15-1/16(383) 23(584) 4(102)' 167(76) 155M24--20 24-1/2(622) 22-7/8(581) 15-1116(383) 23(584) 4(102)_ 171 (77) *. 135 and 155 size furnaces requires a 5 or 6-in.(127 or 152 mm)vent.Use a vent adapter between furnace and vent stack.See Installation Instructions for complete installation requirements Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 2 58SBOB/58SB1 B:Product Data MODEL NUMBER NOMENCLATURE 6 13 1,2 3 4 5 Major 7,8,9 10 11,12 Voltage 14 15,16 Gas Furnace Heating Stages Tier Min.AFUEINOx Series Heating Input Motor Type Width (1-phase) Minor Series Airflow 59 M N 7 B 060 E 17 1 1 16 I I I 08=800 CFM 10=1000 CFM 12=1200 CFM 58=80% 14=1400 CFM Non-Condensing 0=80% 16=1600 CFM 59=90%+ B=Base 1=80%Low NOx C=Constant Airflow 1 20=2000 CFM Condensing M=Modulating C=Comfort (Not Ultra Low Variable-Speed 2 22=2200 CFM T=Two Stage E=Export NOx) (VCA)ECM 3 S=Single Stage N=Infinity 2=92% V=Variable-Speed 14-14.2" 1=110V/60Hz C=Single Stage P=Performance 5=95% 026=26,000 BTU (VCT)PWM 17-17.5" 12=230V/50Hz Communicating U=Ultra Low 6=96% A 040=40,000 BTU M=Multi 18-Speed 21-21.0" Nox 7=97% B 060=60,000 BTU Constant Torque 24-24.5" 8=98% C (MCT)ECM 155=155,000 BTU A220581 FURNACE COMPONENTS CLEARANCES r r r •t INDUCER MOTOR VENT A WARNING ASSEMBLY ELBOW O MAIN LIMIT SWITCH Fr A WARNING INSTALLATION PRESSURE (BEHIND GAS VALVE) MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION SWITCH FIRE,EXPLOSION, This furnace is approved for ASPHYXIATION This forced air furnace is UPFLOW,DOWNFLOW, and equipped for use with natural ® BLOCKED VENT Improper adjustment,alteration,service, gas at altitudes 0-10,000 ft HORIZONTAL installations. SWITCH maintenance,or installation can cause (0-3,050m). t, Clearance arrows serious injury or death. An accessory kit,supplied b � do not change with FLUE COLLECTOR 1 11 ry shall y s furnace orientation. BOX � o FLAME Read and follow instructions and the manufacturer,shall be used ® to convert to propane as use or may be GAS VALVE I SENSOR precautions in User s Information Manual re g tt provided with this furnace.Installation required for some B AC � and service must be performed by a natural gas applications. K _ �c0 I qualified service agency or the gas This O furnace is for indoor supplier. installation in a building 4R o Q constructed on site. sE E MANUALRESET GAS MANIFOLD A CAUTION This furnace may be installed on combustible flooring in alcove DMIT SWITCHES o ® ® Check entire gas assembly for leaks after or closet at minimum clearance a e lighting this appliance. as indicated by the diagram e r HOT SURFACE INSTALLATION from combustible may maybe Clearance in inches IGNITOR This fumace may be used with 1.This furnace must be installed in a Type B-1 Vent and may be I GAS BURNER accordance with the manufacturers vented in common with other ver tclea an�ea wmlwshbles. 0 instructions and local codes. In the gas fired appliances. For Single Wall vents 6 inches(6 po). BLOWER absence of local codes,follow the National For Type B-1 vent type 1 inch(1 po). DOOR SAFETY Fuel Gas Code ANSI Z223.1/NFPA54 SWITCH - or CSA B-149.1 Gas Installation Code. MINIMUM INCHES CLEARANCE TO 2.This furnace must be installed so there are COMBUSTIBLE CONSTRUCTION FURNACE provisions for combustion and ventilation CONTROL m BLOWER AND air.See manufacturer's installation DOWNFLOW POSITIONS: BOARD r MOTOR information provided with this appliance. t Installation on non-combustible floors only. OPERATION For installation on combustible flooring only when installed on i This furnace is equipped with manual reset a manufacturer approved special base kit or manufacturer limit switch(es)in burner compartment to recommended coil assembly. protect against overheat conditions that 0 18 inches front clearance required for alcove. can result from inadequate combustion air supply or blocked vent conditions. * Indicates supply or return sides when furnace is in 1.Do not bypass limit switches. the horizontal position. Line contact only permissible e 2.If a limit opens,call a quallified between lines formed by intersections of the Top and serviceman to correct the condition two Sides of the furnace jacket,and building joists, and reset limit switch. studs or framing. assrni asv.r A190086 A220231 Representative drawing only,some models may vary. The furnaces are factory shipped for use with natural gas.These furnaces can be field-converted for propane gas with a factory-authorized and listed accessory conversion kit. Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 3 58SBOB/58SB113:Product Data SPECIFICATIONS UNIT SIZE 045M14--12 045M17--14 070M14--12 070M17--12 070M17--16 070M21--16 090M17--14 HEATING AND CAPACITY AND EFFICIENCY All Standard 44,000 44,000 66,000 66,000 66,000 66,000 88,000 Input BTUh Low NOx-Upflow Low NOx-Dwnflw/Hz 42,000 42,000 63,000 63,000 63,000 63,000 84,000 All Standard 36,000 35,000 54,000 54,000 54,000 53,000 71,000 Output Capacity(BTUh)t Low NOx-Upflow Low NOx-Dwnflw/Hz 34,000 34,000 51,000 51,000 51,000 51,000 68,000 Certified Temperature Rise Range-°F(°C) 30-60 30-60 30-60 30-60 25-55 25-55 40-70 (17-33) (17-33) (17-33) (17-33) (14-31) (14-31) (22-39) AFUEt 80% AIRFLOW CAPACITY AND BLOWER DATA Rated Certified External Heating 0.10 0.10 0.12 0.12 0.12 0.12 0.15 Static Pressure Cooling 0.50 0.50 0.50 0.50 0.50 0.50 0.50 Airflow CFM @ Rated Heating 715 720 1075 1110 1310 1290 1230 ESP(CFM)* Cooling 175-1095 210-1285 180-1115 155-1160 235-1700 210-1820 330-1490 Direct Drive Motor HP 1/3 1/2 1/3 1/3 3/4 3/4 1/2 Motor Full Load Amps 4.4 6.7 4.4 4.4 8.8 8.8 6.7 Heating Blower Control(Htg OFF-Delay) Adjustable:90, 120(factory-set), 150, 180 seconds Cooling Blower Control(Clg OFF-Delay) Adjustable:90(factory-set),5,30 seconds Blower Wheel Diameter x Width-In.(mm) 10x6 10x8 10x6 10x8 11x8 10x10 10x8 (254x152) (254x203) (254x152) (254x203) (279x203) (254x254) (254x203) Air Filtration System Field Supplied Filter Filter used for Certified Watt Data 325531-40** ELECTRICAL DATA Unit Volts-Hertz-Phase 115-60-1 Operating Voltage Range Min-Max 104-127 Maximum Unit Amps 6.0 7.9 6.0 5.9 10.4 10.4 8.2 Unit Ampacity 8.3 10.7 8.3 8.2 13.8 13.8 11.0 Maximum Wire Length(Measure 1 way in Ft/M) 44/13.6 34/10.6 44/13.6 45/13.80 26/8.2 26/8.2 34/10.3 Minimum Wire Size AWG 14 14 14 14 14 14 14 Max.Fuse/Ckt Bkr Size (Time-Delay Type Amps 15 15 15 15 15 15 15 Recommended) Transformer Capacity(24 VAC output) 40VA External Control Power Heating 12VA Available Cooling 35VA GAS CONTROLS Burners 2 2 3 3 3 3 4 Gas Connection Size 1/2 in.NPT Gas Valve(Redundant) Mfr WhiteRodgerSTM Min.inlet pressure (in.w.c.) 4.5(Natural Gas) Max.inlet pressure (in.w.c.) 13.6(Natural Gas) Ignition Device Silicon Nitride Factory installed orifice Size 43 CONNECTIONS Communication System None Thermostat Connections G,C,W,Y, R Accessory Connections EAC-1 (115 VAC);HUM(24 VAC); 1-STG AC(via Y) *. Gas input ratings are certified for elevations to 2000 ft.(610 M).In USA,For elevations above 2000 ft(610 M),reduce ratings 4 percent for each 1000 ft(305 M)above sea level.Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table F.4 or furnace installation instructions. t. Capacity in accordance with U.S.Government DOE test procedures. $. Airflow shown is for bottom only retum-air supply for the as-shipped speed tap.For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required for each return-air supply.An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in.(110 mm)wide,high efficiency media filter. **. See Accessory List for part numbers available. Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 4 58SBOB/58SB 1 B:Product Data UNIT SIZE 090M21--16 090M21--20 090M24--20 110M21--20 110M24--20 135M24--20 155M24--20 HEATING AND CAPACITY AND EFFICIENCY All Standard gg 000 88,000 88,000 110,000 110,000 132,000 154,000 Input BTUh Low NOx-Upflow Low NOx-Dwnflw/Hz 84,000 84,000 - 105,000 105,000 126,000 147,000 All Standard 72,000 71,000 72,000 90,000 90,000 107,000 125,000 Output Capacity(BTUh)t Low NOx-Upflow Low NOx-Dwnflw/Hz 68,000 68,000 - 85,000 85,000 102,000 119,000 Certified Temperature Rise Range-°F(°C) 35-65 25-55 30-60 30-60 30-60 40-70 45-75 (19-36) (14-31) (17-33) (17-33) (17-33) (22-39) (25-42) AFUEt 80% AIRFLOW CAPACITY AND BLOWER DATA Rated Certified External Heating 0.15 0.15 0.15 0.20 0.20 0.20 0.20 Static Pressure Cooling 0.50 0.50 0.50 0.50 0.50 0.50 0.50 Airflow CFM @ Rated Heating 1325 1645 1515 1840 1970 1805 1945 ESP(CFM)$ Cooling 315-1565 325-2315 265-1980 420-2350 400-2005 290-1925 290-1985 Direct Drive Motor HP 1/2 1 3/4 1 3/4 3/4 3/4 Motor Full Load Amps 6.7 11.5 8.8 11.5 8.8 8.8 8.8 Heating Blower Control(Htg OFF-Delay) Adjustable: 90, 120(factory-set), 150, 180 seconds Cooling Blower Control(Clg OFF-Delay) Adjustable: 90(factory-set),5,30 seconds Blower Wheel Diameter Width -In.(mm) 10x10 11x11 11x11 11x11 11x11 11x11 11x11 (254x254) (279x279) (279x279) (279x279) (279x279) (279x279) (279x279) Air Filtration System Field Supplied Filter Filter used for Certified Watt Data 325531-40** ELECTRICAL DATA Unit Volts-Hertz-Phase 115-60-1 Operating Voltage Range Min-Max 104-127 Maximum Unit Amps 8.2 13.9 10.7 14.4 11.1 11.0 10.7 Unit Ampacity 11.0 18.1 14.1 18.6 14.6 14.4 14.1 Maximum Wire Length(Measure 1 way in Ft/M) 34/10.3 31/9.6 26/8.0 30/9.4 25/7.7 25/7.8 26/8.0 Minimum Wire Size AWG 14 12 14 12 14 14 14 Max.Fuse/Ckt Bkr Size (Time-Delay Type Amps 15 20 15 20 15 15 15 Recommended) Transformer Capacity(24 VAC output) 40VA External Control Power Heating 12VA Available Cooling 35VA GAS CONTROLS Burners 4 4 4 5 5 6 6 Gas Connection Size 112 in. NPT Gas Valve(Redundant) Mfr WhiteRodgerS' Min. inlet pressure (in.w.c.) 4.5(Natural Gas) Max.inlet pressure (in.w.c.) 13.6(Natural Gas) Ignition Device Silicon Nitride Factory installed orifice Size 43 CONNECTIONS Communication System None Thermostat Connections G,C,W,Y, R Accessory Connections EAC-1 (115 VAC);HUM(24 VAC); 1-STG AC(via Y) *. Gas input ratings are certified for elevations to 2000 ft.(610 M).In USA,For elevations above 2000 ft(610 M),reduce ratings 4 percent for each 1000 ft(305 M)above sea level.Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table FA or furnace installation instructions. t. Capacity in accordance with U.S.Government DOE test procedures. $. Airflow shown is for bottom only retum-air supply for the as-shipped speed tap.For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required for each return-air supply.An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in.(110 mm)wide,high efficiency media filter. **. See Accessory List for part numbers available. Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 5 58SBOB/58SB 1 B:Product Data AIR DELIVERY (with filter) Air Delivery-CFM(with filter)* Unit Size Airflow Setting Default Setting External Static Pressure(in.w.c. 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Constant Fan 55 5 5 75 -- -- -- -- 2 490 425 360 300 225 150 -- 3 535 480 415 360 305 230 160 4 565 510 450 395 345 285 215 135 -- 5 605 555 500 445 390 345 285 215 145 6 645 595 545 490 440 395 350 290 225 155 7 695 645 600 550 500 455 410 370 310 255 8 Heating 715 670 625 575 530 485 440 400 355 290 0451014--12 9 770 730 685 640 595 555 510 470 430 390 10 825 780 740 700 660 615 575 535 500 460 11 870 830 795 755 720 680 640 600 560 525 12 920 880 845 810 775 735 700 660 625 590 13 965 930 895 855 825 790 755 720 685 650 14 1005 970 935 905 875 840 805 770 740 705 15 1055 1020 990 960 930 895 865 835 800 770 16 1105 1070 1040 1010 980 950 925 895 860 830 17 1125 1095 1065 1035 1005 975 950 920 890 860 18 Cooling 1210 1180 1150 1120 1095 1065 1040 1010 980 945 1 Constant Fan 495 425 345 270 210 135 -- -- -- -- 2 540 475 400 330 270 205 135 -- 3 580 520 455 380 320 260 200 160 4 635 575 520 450 385 330 275 215 155 -- 5 685 630 570 515 450 390 340 290 235 180 6 Heating 720 665 615 560 505 445 395 345 295 245 7 770 720 665 615 565 505 450 400 355 310 8 830 785 735 690 640 590 535 485 440 395 045M17--14 9 880 840 790 745 705 660 610 555 510 465 10 945 905 860 815 775 735 690 645 595 550 11 1005 965 920 880 840 800 760 725 680 630 12 1060 1025 985 940 905 865 825 790 750 710 13 1120 1085 1050 1010 970 935 900 865 830 795 14 1170 1135 1100 1065 1030 995 960 925 890 855 15 1235 1205 1170 1135 1100 1065 1035 1000 965 915 16 1295 1265 1235 1200 1170 1135 1105 1075 1020 930 17 1365 1335 1305 1270 1240 1210 1180 1125 1035 930 18 Cooling 1460 1420 1375 1330 1285 1235 1190 1130 1035 930 Constant Fan 465 400 330 2505 -- -- -- -- 2 500 440 370 295 225 165 115 - 3 550 490 430 365 300 235 175 130 --- 4 595 540 485 425 355 295 240 185 135 5 635 580 530 475 420 355 300 245 195 145 6 675 625 575 525 470 410 355 300 250 205 7 715 670 625 575 525 475 420 370 320 270 8 760 720 675 630 585 535 490 435 390 340 070M14--12 9 805 765 725 685 640 595 550 505 455 410 10 855 820 780 740 700 660 615 575 530 485 11 905 870 835 795 760 720 685 645 600 560 12 950 915 880 845 810 775 740 700 665 625 13 1005 970 940 905 870 840 805 770 735 700 14 1055 1020 990 960 930 895 865 830 800 765 15 Heating 1085 1055 1025 995 965 935 900 870 840 810 16 1120 1090 1060 1030 1000 970 940 910 880 850 17 1150 1120 1095 1065 1035 1005 975 945 920 890 18 Cooling 1220 1195 1170 1140 1115 1090 1060 1035 1005 970 Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 6 58SBOB/58SB1 B:Product Data Air Delivery-CFM(with filter)*(Continued) Unit Size Airflow Setting Default Setting External Static Pressure in.w.c. 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Constant Fan - -- -- -- 2 515 430 350 275 200 130 -- 3 565 490 410 340 270 205 140 -- 4 610 540 470 400 335 265 210 150 -- 5 655 590 525 455 395 330 270 215 155 -- 6 700 635 570 505 445 385 325 270 220 165 7 740 685 620 560 500 445 390 335 280 235 8 790 735 675 620 565 510 455 400 350 300 070M17--12 9 835 785 730 675 620 570 515 465 415 365 10 880 830 780 725 675 625 575 525 480 430 11 935 890 840 790 740 690 645 595 550 505 12 985 940 895 845 800 750 705 665 620 575 13 1035 990 950 900 855 810 770 730 685 640 14 1080 1040 995 950 910 865 825 785 745 705 15 Heating 1120 1075 1035 995 950 910 870 830 790 750 16 1175 1140 1100 1060 1020 980 940 905 865 830 17 1225 1190 1155 1115 1080 1040 1000 965 930 895 18 Cooling 1300 1265 1230 1190 1160 1120 1085 1050 1015 980 ons an an 545 465 385 310 235 155 -- -- -- -- 2 605 535 455 385 315 250 175 - -- -- 3 665 595 530 460 395 330 270 205 -- 4 740 675 615 550 490 430 370 315 255 190 5 810 750 690 635 570 515 460 405 355 305 6 870 815 760 705 650 595 545 490 440 390 7 955 900 850 795 745 695 645 595 545 495 8 1025 975 925 880 835 785 735 685 645 595 070M17--16 9 1095 1050 1005 955 915 870 820 770 730 685 10 1175 1135 1090 1045 1005 960 920 875 830 790 11 1220 1180 1135 1095 1055 1015 975 935 890 850 12 Heating 1320 1285 1245 1205 1170 1130 1095 1055 1015 980 13 1390 1355 1315 1280 1245 1210 1170 1135 1100 1065 14 1475 1435 1405 1370 1335 1300 1265 1235 1200 1165 15 1550 1520 1485 1450 1415 1385 1350 1320 1290 1260 16 1630 1600 1570 1540 1510 1480 1450 1420 1390 1365 17 1705 1675 1640 1615 1590 1560 1535 1505 1480 1455 18 Cooling 1840 1810 1775 1735 1700 1660 1620 1580 1540 1500 1 onstant an 590 495 390 290 210 120 -- -- -- -- 2 665 580 485 390 300 225 145 - -- -- 3 730 655 565 480 385 310 245 170 -- 4 820 750 675 595 520 435 360 300 235 165 5 875 810 740 665 595 515 435 370 315 250 6 950 885 830 760 695 625 550 480 410 360 7 1045 985 930 875 810 750 685 620 555 490 8 1140 1085 1030 980 925 865 810 750 695 635 070M21--16 9 1200 1145 1095 1050 1000 945 885 835 780 730 10 Heating 1300 1250 1195 1155 1110 1065 1015 960 910 865 11 1370 1320 1275 1230 1190 1150 1105 1055 1005 960 12 1455 1410 1365 1325 1285 1245 1205 1165 1115 1070 13 1535 1490 1450 1415 1375 1340 1305 1265 1225 1185 14 1615 1575 1535 1495 1460 1425 1390 1355 1320 1285 15 1705 1670 1635 1600 1565 1535 1505 1470 1435 1400 16 1775 1745 1710 1680 1650 1620 1590 1560 1530 1505 17 1870 1840 1810 1780 1750 1725 1705 1670 1630 1530 18 Cooling 2025 1975 1925 1875 1820 1770 1725 1680 1630 1535 Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 7 58SBOB/58SB1 B:Product Data Air Delivery-CFM(with filter)*(Continued) Unit Size Airflow Setting Default Setting External Static Pressure in.w.c. 0.1 1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Constant Fan --- 2 705 635 535 450 380 305 235 180 125 -- 3 760 695 625 520 450 380 310 245 195 145 4 810 750 685 585 515 450 385 320 260 210 5 860 800 745 675 580 510 450 390 325 270 6 910 855 800 740 650 580 515 460 400 345 7 950 900 850 790 730 640 575 515 465 410 8 1025 975 925 875 820 740 670 615 560 510 090M17--14 9 1075 1030 985 935 885 835 745 690 630 580 10 1140 1095 1050 1005 960 910 855 775 715 665 11 1210 1165 1125 1085 1040 995 950 895 815 760 12 Heating 1255 1210 1170 1130 1085 1045 1000 955 880 820 13 1280 1235 1200 1160 1115 1075 1030 990 925 855 14 1340 1300 1265 1225 1185 1145 1105 1065 1025 965 15 1410 1370 1335 1300 1265 1225 1190 1150 1110 1070 16 1475 1440 1405 1370 1335 1300 1265 1225 1190 1150 17 1550 1515 1480 1445 1415 1380 1345 1310 1270 1235 18 Cooling 1620 1585 1555 1520 1490 1460 1425 1375 1315 1255 ons an an tjdb b6b 490 395 315 240 170 -- -- -- 2 745 660 560 480 390 320 250 185 -- -- 3 810 725 635 550 475 395 325 265 200 -- 4 860 785 700 615 540 465 395 335 275 215 5 915 845 765 680 610 535 465 400 345 285 6 980 910 840 765 690 620 555 490 425 370 7 1040 980 910 840 770 700 635 575 510 450 8 1100 1040 975 910 840 770 710 650 590 530 090M21--16 9 1170 1110 1055 995 930 870 800 745 685 630 10 1225 1170 1110 1055 995 930 865 810 755 700 11 1295 1245 1195 1135 1085 1025 970 905 850 795 12 1315 1265 1215 1160 1110 1055 1000 935 880 830 13 Heating 1350 1300 1250 1195 1145 1090 1035 975 915 865 14 1420 1375 1330 1280 1230 1185 1130 1075 1020 960 15 1495 1455 1405 1360 1315 1270 1220 1170 1120 1060 16 1565 1525 1480 1435 1395 1350 1305 1260 1210 1160 17 1645 1605 1565 1525 1480 1435 1390 1345 1300 1250 18 Cooling 1725 1680 1645 1605 1565 1520 1480 1420 1340 1260 1 onstant an 770 655 325 195 -- -- -- -- 2 850 745 640 535 435 340 210 - 3 925 825 725 625 530 435 345 230 -- 4 1030 940 845 755 665 575 490 405 315 185 5 1120 1040 950 865 780 700 615 540 455 380 6 1210 1130 1050 970 895 810 735 655 580 510 7 1285 1215 1140 1065 990 915 840 765 690 620 8 1385 1320 1250 1180 1110 1040 975 900 835 765 090M21--20 9 1480 1415 1355 1290 1215 1155 1090 1025 960 895 10 1570 1510 1450 1390 1325 1260 1200 1140 1080 1015 11 Heating 1675 1615 1560 1505 1450 1390 1330 1270 1210 1155 12 1775 1720 1670 1615 1560 1510 1450 1395 1340 1285 13 1865 1815 1765 1715 1660 1610 1555 1500 1450 1395 14 1965 1920 1875 1825 1780 1730 1680 1630 1580 1535 15 2075 2030 1985 1940 1895 1845 1805 1760 1710 1660 16 2170 2135 2090 2050 2005 1965 1925 1880 1835 1790 17 Cooling 2270 2225 2190 2150 2115 2075 2035 2000 1960 1920 18 2485 2445 2410 2365 2315 2265 2215 2160 2105 2050 Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 8 58SBOB/58SB1 B:Product Data Air Delivery-CFM(with filter)*(Continued) Unit Size Airflow Setting Default Setting External Static Pressure in.w.c. 0.1 0.2 0.3 0.4 0.5 $295 0.7 0.8 0.9 1 Constant an -- -- -- 2 830 720 610 495 395 175 --3 890 790 680 570 470 280 160 --4 975 880 775 675 575 405 310 1955 1050 960 865 770 680 500 425 340 235 6 1120 1035 950 860 770 685 595 515 445 360 7 1210 1130 1050 965 880 800 715 635 565 495 8 1295 1220 1140 1065 985 905 830 755 670 605 090M24--20 9 1395 1320 1250 1180 1100 1030 955 885 810 735 10 1460 1390 1325 1255 1190 1115 1045 975 905 840 11 Heating 1550 1485 1420 1355 1295 1225 1155 1090 1020 960 12 1615 1550 1490 1430 1370 1305 1240 1175 1110 1045 13 1710 1650 1595 1535 1475 1420 1355 1295 1235 1175 14 1785 1730 1675 1615 1560 1510 1450 1390 1330 1275 15 1890 1835 1780 1725 1675 1620 1570 1520 1460 1410 16 1970 1920 1865 1815 1765 1715 1670 1620 1570 1520 17 2050 2000 1950 1905 1855 1810 1760 1720 1675 1625 18 Cooling 2170 2120 2070 2025 1980 1930 1880 1820 1765 1695 Constant an 845 f3u b2b 520 420 330 240 135 -- -- 2 920 810 705 610 515 425 345 260 155 -- 3 1025 920 825 735 645 560 475 400 320 245 4 1115 1015 930 840 760 675 595 520 445 380 5 1235 1150 1060 980 900 825 750 675 600 525 6 1340 1260 1180 1100 1025 955 885 810 740 675 7 1440 1365 1290 1215 1140 1070 1005 940 875 805 8 1530 1460 1390 1320 1250 1185 1115 1055 995 930 110M21--20 9 1640 1575 1510 1440 1375 1310 1250 1190 1130 1075 10 1745 1685 1620 1555 1495 1430 1370 1315 1260 1205 11 1835 1780 1720 1665 1605 1550 1490 1435 1380 1330 12 Heating 1895 1840 1785 1730 1675 1615 1560 1505 1455 1400 13 1950 1895 1840 1785 1725 1670 1615 1565 1510 1460 14 2055 2005 1955 1900 1845 1790 1740 1690 1640 1590 15 2160 2110 2065 2015 1960 1910 1860 1815 1765 1720 16 Cooling 2260 2210 2165 2120 2070 2020 1975 1930 1885 1840 17 2355 2310 2265 2225 2180 2135 2090 2045 2005 1960 18 2520 2480 2435 2395 2350 2310 2255 2195 2135 2080 1 Constant Fan 840 725 615 505 400 310 215 135 -- -- 2 930 825 720 620 520 420 335 250 165 -- 3 1015 915 815 725 630 530 440 360 280 205 4 1095 995 905 815 725 635 540 460 385 310 5 1185 1090 1005 915 835 750 665 580 500 430 6 1250 1160 1080 1000 915 840 755 675 595 525 7 1335 1255 1175 1100 1020 940 870 790 710 635 8 1435 1355 1280 1210 1140 1060 990 920 845 780 110M24--20 9 1510 1435 1360 1290 1225 1155 1085 1015 950 880 10 1600 1530 1455 1390 1325 1260 1190 1125 1060 995 11 1685 1615 1545 1480 1420 1360 1295 1230 1165 1110 12 1760 1695 1630 1565 1505 1450 1390 1330 1270 1210 13 1855 1795 1730 1670 1610 1560 1505 1445 1385 1330 14 1945 1885 1830 1770 1710 1655 1605 1555 1495 1445 15 Heating 2025 1970 1915 1855 1800 1750 1700 1650 1600 1550 16 2055 2000 1945 1890 1835 1785 1735 1685 1635 1585 17 2125 2070 2015 1965 1910 1860 1815 1765 1720 1670 18 Cooling 2220 2170 2115 2060 2005 1960 1905 1860 1810 1750 Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 9 58SBOB/58SB1 B:Product Data Air Delivery-CFM(with filter)*(Continued) Unit Size Airflow Setting Default Setting External Static Pressure in.w.c. 0.1 0.2 0.3 1740 .4 0.5 0.6 0.7 0.8 0.9 1 Constant an -- 2 815 700 590 85 370 270 155 3 905 795 685 90 490 380 290 185 -- 4 975 870 770 80 590 490 395 310 205 5 1025 920 825 655 560 460 375 290 195 6 1120 1025 935 845 770 690 600 505 420 350 7 1205 1120 1030 945 870 800 720 635 550 470 8 1285 1200 1120 1040 965 900 830 750 675 590 135M24--20 9 1380 1305 1225 1150 1075 1010 950 885 815 735 10 1450 1380 1305 1230 1160 1095 1030 975 910 840 11 1555 1480 1415 1345 1275 1210 1150 1095 1045 985 12 1635 1565 1500 1435 1370 1310 1245 1190 1140 1090 13 1710 1645 1585 1525 1460 1400 1340 1285 1230 1185 14 1785 1725 1665 1600 1545 1485 1425 1375 1320 1275 15 Heating 1870 1805 1750 1695 1640 1580 1525 1475 1420 1375 16 1940 1885 1830 1780 1725 1675 1620 1570 1520 1475 17 2020 1965 1915 1865 1815 1765 1715 1665 1620 1580 18 Cooling 2125 2075 2025 1975 1925 1875 1825 1775 1705 1640 Constant an 765 645 520 395 290 185 -- 2 860 750 635 520 410 315 220 145 -- -- 3 915 810 705 600 485 385 300 210 135 -- 4 1000 895 795 695 595 490 400 320 230 145 5 1075 975 880 790 695 595 500 420 335 260 6 1170 1075 985 900 815 730 635 545 470 390 7 1260 1170 1090 1010 930 845 765 675 590 510 8 1340 1255 1180 1100 1025 950 870 795 710 625 155M24--20 9 1415 1340 1260 1190 1120 1045 970 895 815 745 10 1505 1430 1355 1290 1220 1150 1080 1010 945 870 11 1575 1500 1430 1365 1295 1230 1165 1100 1030 970 12 1660 1590 1520 1455 1395 1335 1275 1210 1140 1085 13 1735 1670 1605 1545 1485 1425 1365 1310 1250 1185 14 1825 1760 1700 1640 1585 1530 1475 1425 1365 1310 15 1920 1860 1800 1740 1685 1630 1580 1530 1475 1420 16 Heating 2000 1945 1890 1825 1775 1725 1675 1625 1575 1525 17 2085 2035 1980 1925 1870 1825 1780 1740 1695 1650 18 Cooling 2205 2150 2095 2040 1985 1935 1885 1835 1775 1720 NOTE: 1. A filter is required for each retum-air inlet.Airflow performance included 3/4-in.(19 mm)washable filter media such as contained in a factory-authorized accessory filter rack.See accessory list.To determine airflow performance without this filter,assume an additional 0.1 in.w.c.available external static pressure. 2. Adjust the blower airflow setting as necessary for the proper air temperature rise for each installation. 3. Airflows over 1800 CFM require bottom return,two-side return,or bottom and side return.A minimum filter size of 20"x 25"(508 x 635 mm)is required. 4. For upflow applications,air entering from one side into both the side of the furnace and a return air base counts as aside and bottom return. 5. The--entry indicates unstable operating conditions. Airflow Settings Default Airflow Settings Designated Airflow Settings Unit Size Heating Cooling Heating Constant Fan 0451VI 14--12 8 18 (4-12) (1-7) 0451VI 17--14 6 18 (4-12) (1-7) 070M 14--12 15 18 (9-16) (1-7) 070M17--12 15 18 (11-17) (1-8) 070M17--16 12 18 (7-13) (1-4) 070M21--16 10 18 (6-14) (1-8) 090M 17--14 12 18 (7-16) (1-9) 090M21--16 13 18 (8-16) (1-6) 090M21--20 11 17 (7-14) (1-9) 090M24--20 11 18 (7-16) (1-10) 110M21--20 12 16 (8-15) (1-9) 110M24--20 15 18 (9-17) (1-6) 135M24--20 15 18 (12-16) (1-7) 155 M24--20 16 18 (13-17) (1-2) *. Setting 91 is the default setting for Constant Fan Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 10 58SBOB/58SB1 B:Product Data TYPICAL WIRING SCHEMATIC FURNACE CONTROL BOARD 7-SEGM ENT DISPLAY PLUG CCNNERDR-SER-E — FIELD24-VWIRING a Y AN °NR ROARDRE NTUSE°NLY ----FIELD 115-,208/230-,460-VWIRING FACTORY 24-V WIRING p p —FACTORY 115-V WIRING 8 8 8. iiue" ANrE NNA r, K WIN �N�rG NOTE THERMOSTAT 0 + FIVEWIRE w c a c v TERMINALS FIELD-SUPPLIED III a«Lr " ' x Ftx THREE WIRE DISCONNECT a N x�� N.N x,AVP_, HEATING-ONLY _ ° 208/230.OR BLOWER DOOR SWITCH N 460-V ER NN r A - THREE " N I I �7 PHASE ar :4 c o ow• p � Lau*nx O O __ __. - 'cook" w_ _____ __ 0 n ETATDR GE.— c"" N - -- 208/230-V =GND �cr10 T ___ ____ __l _1_ __ _ lSINGLE w ,- w =rp NER= AUXILIARY R G __1 PHASE 115-V FIELD- p ° 01 SUPPLIED J-B0X L® - -----' It_ _ ___2GND FO ?; DISCONNECT ---NOTE-----; _0 ;o„;o UNITDENSING —NE—S O •0 O O p O QF O 24-V TWO rcun L. J. " rxoxsr TERM LOCK It WIRE NN l R�,a�g Y� Aro BLOCK `ate°�'.aE G,TERN.w / ,-0. T. E< D„� , „x IL„uxEw .E FURNACE NOTES:1. ConnectY-terminal in furnace as shown for proper blower operation. ^°N 2. Some thermostats require a"C"terminal connection as shown. RMo.oRDxE 3. If any of the original wire,as supplied,must be replaced,use wL=�E=ate=oN `" R N. R"R same Noe or eauivalent wire. A210192 A190079 VENTING CONFIGURATIONS IlIIIlQ M-1111 O O SEE NOTES:1,2,4,5,7,8,9 SEE NOTES:1,2,3,4,5,7,8,9 on the page following on the page following these figures these figures A03210 A03211 Downflow Application-Vent Elbow Up then Left Downflow Application-Vent Elbow Up o. i i o i I SEE NOTES:1,2,4,5,6,7,8,9 SEE NOTES:1,2,3,4,7,8,9 on the page following these figures on the pages following these figures A03207 A03209 Downflow Application-Vent Elbow Left then Up Upflow Application-Vent Elbow Right O --- - hII p o I, SEE NOTES:1,2,4,7,8,9 on the page following these figures SEE NOTES:1,2,4,5,7,8,9 A03213 A02068 Horizontal Left Application-Vent Elbow Left Horizontal Right Application-Vent Elbow Left Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 11 58SBOB/58SB1B:Product Data IIELU] O o. o I, SEE NOTES:1,2,4,5,7,8,9 on the page following these figures A03219 Horizontal Right Application-Vent Elbow Left then Up SEE NOTES:1,2,4,7,8,9 I I11111111 on the page following these figures =_ A03208 Upflow Application-Vent Elbow Up IL 0 ail ii ci ---- -� O 11 R ii •0 SEE NOTES:1,2,4,5,7,8,9 on the page O following these figures A03214 Horizontal Left Application-Vent Elbow Right then Up Venting notes: 1. For common vent,vent connector sizing and vent material:United States, ° latest edition of the National Fuel Gas Code(NFGC),ANSI Z223.1/NFPA 54. 2. Immediately increase to 5-in. (127 mm) vent connector outside furnace casing when 5-in.(127 mm)vent connector required,refer to Note 1. SEE NOTES:1,2,3,4,5,7,8,9 on the page following 3. Side outlet vent for upflow and downflow installations must use Type B these figures. vent immediately after exiting the furnace, except when Downflow Vent Downflow Application-Vent Elbow Up then Right A03212 Guard is used in downflow position. 4. Type B vent where required,refer to Note 1. il• 5. 4-in.(102 mm)single wall vent must be used inside furnace casing and the O Downflow Vent Guard Kit. 6. Accessory Downflow Vent Guard Kit required in downflow installations it with bottom vent configuration. ll 7. Chimney Adapter Kit required for exterior masonry chimney applications. I' Refer to Chimney Adapter Kits for sizing and complete application details. SEE NOTES: ,4,,8,9 on the page following these 8. Secure vent connector to furnace elbow with(2)corrosion-resistant sheet e figures A03218 metal screws,space approximately 180 apart. Horizontal Right Application-Vent Elbow Right 9. Secure all other single wall vent connector joints with (3) corrosion-resistant screws spaced approximately 120 apart. Secure Type B vent connectors per vent connector manufacturer's recommendations. a O SEE NOTES:12,A5,7,8,9 on the page following these figures A03216 Horizontal Left Application-Vent Elbow Right luluw -- al 0 O .t SEE NOTES:1,2,4,5,7,8,9 on the page following these figures A03215 Horizontal Left Application-Vent Elbow Up Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 12 58S13013/58S13113:Product Data ACCESSORIES PART NO. DESCRIPTION 045M14--12 045M17--14 070M14--12 070M17--12 070M17--16 070M21--16 090M17--14 ACG1425NCB* External Filter Rack, 14-1/2 x 25" X X ACG1625NCF* External Filter Rack, 16 x 25" - X - X X - X ACG2025NCJ* External Filter Rack,20 x 25" - - - - X 325531-402 Washable filter,3/4"x 16"x 25" X X X X X - X 325531-403* Washable filter,3/4"x 21"x 25" - - - - X - KGADA0101ALL Coil Adapter Kits-No Offset X X X X X X X KGADA0201ALL Coil Adapter Kits-Single Offset X X X X X X X KGADA0301ALL Coil Adapter Kits-Double Offset X X X X X X X KGARP0301B14 Return Air Base(Upflow Applications) X - X - - - - 14-3/16"wide KGARP0301B17 Return Air Base(Upflow Applications) - X - X X - X 17-1/2"wide KGARP0301B21 Return Air Base(Upflow Applications) - - - X - 21"wide KGACA02014FC Chimney Adapter Kit,up to or equal to X X X X X X X 11 OK BTUh KGAFE0112UPH Flue Extension X X X X X X X KGAVE0101DNH Vent Extension Kit X X X X X X X Combustible Floor Base(Not KGASB0201ALL required when evaporator coil case X X X X X X X is used for downflow KGBVG0101 DFG Downflow Vent Guard(Not required X X X X X X X when vent is routed through cabinet AGAGC8NPS01B* Natural-to-Propane Conversion Kitt X X X X X X X AGAGC8PNS01B* Propane-to-Natural Conversion Kitt X X X X X X X AGATWNPUA01A Twinning Kit - - - X - *. Purchased through Replacement Components t. Factory-authorized and field installed.Fuel conversion kits are CSA recognized. X=Accessory Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 13 58S13013/58SI3113:Product Data ACCESSORIES (Continued) PART NO. DESCRIPTION 090M21--16 090M21--20 090M24--20 110M21--20 110M24--20 135M24--20 155M24--20 ACG2025NCJ* External Filter Rack X X X 20 x 25" ACG2424NCL' External Filter Rack _ X - X X X 24-1/2 x 24" 325531-403* Washable filter X X X - - 3/4"x21"x25" 325531-404* Washable filter _ X - X X X 3/4"x 24"x 25" KGADA0101ALL Coil Adapter Kits-No Offset X X X X X X X KGADA0201ALL Coil Adapter Kits-Single X X X X X X X Offset KGADA0301ALL Coil Adapter Kits-Double X X X X X X X Offset KGARP0301 B21 Return Air Base(Upflow X X X - - Applications)21"wide KGARP0301 B24 Return Air Base(Upflow X - X X X Applications)24-1/2 wide KGACA02014FC Chimney Adapter Kit,up to X X X X X or equal to 11 OK BTUh Chimney Adapter Kit, KGACA02015FC greater than or equal to - - - X X 135K BTUh KGAFE0112UPH Flue Extension X X X X X X X KGAVE0101 DNH Vent Extension Kit X X X X X X X Combustible Floor Base(Not KGASB0201ALL required when evaporator X X X X X X X coil case is used for down- flow Downflow Vent Guard(Not KGBVG0101 DFG required when vent is routed X X X X X X X through cabinet Natural-to-Propane AGAGC8NPS01B X X X X X X X Conversion Kitt Propane-to-Natural AGAGC8PNS01 B Conversion Kitt X X X X X X X AGATWNPUA01A Twinning Kit X X X X X X X *. Purchased through Replacement Components t. Factory-authorized and field installed.Fuel conversion kits are CSA recognized. X=Accessory ORFICIES Gas Orifice Kit-#42(Nat Gas) LH32DB207 Gas Orifice Kit-#43(Nat Gas) LH32DB202 Gas Orifice Kit-#44(Nat Gas) LH32DB200 Gas Orifice Kit-#45(Nat Gas) LH32DB205 Gas Orifice Kit-#46(Nat Gas) LH32DB208 Gas Orifice Kit-#47(Nat Gas) LH32DBO78 See Installation Instructions for model,altitude, Gas Orifice Kit-#48(Nat Gas) LH32DBO76 and heat value usages. Gas Orifice Kit-#54(LP) LH32DB203 Gas Orifice Kit-#55(LP) LH32DB201 Gas Orifice Kit-#56(LP) LH32DB206 Gas Orifice Kit-1.25mm(LP) LH32DB209 Gas Orifice Kit-1.30mm(LP) LH32DB210 DESCRIPTION ACCESSORY HUMIDIFIER Model HUM HEAT RECOVERY VENTILATOR Model HRV ENERGY RECOVERY VENTILATOR Model ERV UV LIGHTS Model UVL Carrier has a wide variety of thermostats for your system,please visit www.Carrier.com to see all thermostat and IAQ products. Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 14 58SBOB/58SB113:Product Data ACCESSORIES (Continued) DESCRIPTION ACCESSORY 14" 17" 21" 24" Carrier Carbon Monoxide Alarm(10 pack) COALMCCNRB02-AlO X X X X Carrier Infinity Air Purifier-16x25(407x635 mm) DGAPAXX1625 X X Carrier Infinity Air Purifier-20x25(508x635 mm) DGAPAXX2025 X X Carrier Infinity Air Purifier Repl. Filter-16x25(407x635 mm) GAPCCCAR1625-A05 X X Carrier Infinity Air Purifier Repl. Filter-20x25(508x635 mm) GAPCCCAR2025-A05 X X Cartridge Media Filter-16"(407 mm)(MERV 11) FILXXCAR0116 X X Cartridge Media Filter-16"(407 mm)(MERV 8) FILXXCAR0016 X X Cartridge Media Filter-20"(508 mm)(MERV 8) FILXXCAR0020 - X Cartridge Media Filter-20"(508 mm)(MERV11) FILXXCAR0120 - X Cartridge Media Filter-24"(610 mm)(MERV 8) FILXXCAR0024 X Cartridge Media Filter-24"(610 mm)(MERV11) FILXXCAR0124 X EZ Flex Cabinet Side or Bottom-16" EZXCAB--0016 X X EZ Flex Cabinet Side or Bottom-20" EZXCAB--0020 X X EZ Flex Replacement Filters 16"MERV 10 EXPXXFIL0016 X X EZ Flex Replacement Filters 16"MERV 13 EXPXXFIL0316 X X - EZ Flex Replacement Filters 20"MERV 10 EXPXXFIL0020 X EZ Flex Replacement Filters 20"MERV 13 EXPXXFIL0320 X EZ Flex Replacement Filters 24"MERV 10 EXPXXFIL0024 - X EZ Flex Replacement Filters 24"MERV 13 EXPXXFIL0324 X EZ-Flex Filter with End Caps-16"(407 mm)(MERV 10) EXPXXUNV0016 X X EZ-Flex Filter with End Caps-16"(407 mm)(MERV 13) EXPXXUNV0316 X X EZ-Flex Filter with End Caps-20"(508 mm)(MERV 10) EXPXXUNV0020 X EZ-Flex Filter with End Caps-20"(508 mm)(MERV 13) EXPXXUNV0320 X EZ-Flex Filter with End Caps-24"(610 mm)(MERV 10) EXPXXUNV0024 X EZ-Flex Filter with End Caps-24"(610 mm)(MERV 13) EXPXXUNV0324 X Media Filter Cabinet-20" FILCABXL0020 X Media Filter Cabinet-24" FILCABXL0024 X Media Filter Cabinet-16" FILCABXL0016 X X ©2025 Carrier.All rights reserved. Edition Date:01/25 Catalog No:58SBOB-01PD REV A Replaces:58SBOB-01PD Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. 15 Permit#: 6567 Permit Date: 06/19/25 Permit Type: RESIDENTIAL MECHANICAL Project Name: Andrew 391375832 Applicant Name: Home Comfort Alliance Applicant Address: 3409 Everett Ave Applicant, City, State, Zip: Everett Wa 98201 Contact: Pat Andrews Phone: 253-381-5598 Email: patjandrew@gmail.com Scope of Work: Furnace Valuation: 3500.00 Square Feet: 1515 Number of Stories: 2 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 08/13/2025 Permit Expires: 02/09/2026 Form Permit Type: RESIDENTIAL MECHANICAL Status: COMPLETE Assigned To: Hannah Hardwick Property Parcel# Address Legal Description Owner Name Owner Phone Zoning GARD KIMBERLY 100 SINGLE 00378800500300 128 N DUNHAM AVE M FAMILY RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License# Home Comfort Alliance 425-563-9172 3409 Everett Ave CONSTRUCTION UBI 603 537 854 CONTRACTOR Home Comfort Alliance 425-563-9172 3409 Everett Ave CONSTRUCTION L&I HOMECCA785BD CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status R15. O1/13/2026 MECHANICAL Tenant will be present. 01/14/2026 01/14/2026 BUILDING Approved FINAL Fees Fee Description Notes Amount Processing/Technology $25.00 Inspection $75.00 Forced Air Heat<100 BTU/h Enter#of units $15.00 Mechanical Base Permit Fee $25.00 Credit Card Service $4.20 Total $144.20 Attached Letters Date Letter Description 07/22/2025 Building Permit 06/19/2025 Web Form-Residential Mechanical Application Payments Date Paid By Description Payment Type Accepted By Amount 06/19/2025 Home Comfort 234669498 Hannah Hardwick $4.20 06/19/2025 XBP Con£ $140.00 234669498 Outstanding Balance $0.00 Notes Date Note Created By: 12/29/2025 sent expiration notice Hannah Hardwick 07/10/2025 emailed homeowner again for spec sheet. Hannah Hardwick 06/20/2025 emailed applicant to sign the application and send spec sheet over. Hannah Hardwick Uploaded Files Date File Name 08/14/2025 27823792-20250813 BLD6567 IssuedPermit.pdf 06/25/2025 27042930-20250625 BLD6567 App-Signed.pdf 06/19/2025 eca9676cl3caf8d5432657bbfd3ee824 andrew 391375832 mech pgrmit.pdf