HomeMy WebLinkAbout522 E 3RD ST_BLD1282_2026 CITY OF ARLINGTON
238 N. OLYMPIC AVE -ARLINGTON, WA. 98223
PHONE; (360)403-3551
BUILDING PERMIT
Address:522 E 3rd Street Permit#:1282
Parcel#:00455400101901 Valuation:0.00
OWNER APPLICANT CONTRACTOR
Name:SCHELLER BEVERLY KAY Name:Kay Scheller Name:Kay Sheller
Address:PO BOX 95 Address:917 Webster Ave Address:917 Webster Ave
City,State Zip:MUKILTEO,WA 98275 City,State Zip:Mukilteo,WA 98275 City,State Zip:Mukilteo,WA 98275
Phone:425-280-7194 Phone:425-583-4201 Phone:425-583-4201
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Name: Name:
Address: Address:
City,State,Zip: City,State,Zip:
Phone: Phone:
LIC#: EXP: LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Residential Mechanical CODE YEAR: 2015
STORIES: CONST.TYPE:
DWELLING UNITS: 1 OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED
THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO
WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRCI10.
SALES TAX NOTICE:Sales tax W ng to con ruction and construction materials in the ity of Arlington must be reported on your sales tax return form
n ded i ofArlinglo
i vy �.tom� l/ ZO17
Signpr& PrinVName Mtc Released By ate
CONDITIONS
Approved as submitted. See attached Sediment Trap Detail 408.4 for required installation details.
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY
CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
1/11/2017 Gas Outlets Base Fee 1 to 5 $10.00
1/11/2017 Mechanical Fee(Enter Fixture Fee) $25.00
1/11/2017 Mechanical Permit Base Fee $25.00
1/11/2017 Processingrrechnology Fee $25.00
Total Due: $85.00
Total Payment: $0.00
Balance Due: $85.00
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
' CITY OF ARLINGTON
238 N. OLYMPIC AVE -ARLINGTON, WA. 98223
PHONE; (360)403-3551
BUILDING PERMIT
Address:522 E 3rd Street Permit#:1282
Parcel#:00455400101901 Valuation:0.00
OWNER APPLICANT CONTRACTOR
Name:SCHELLER BEVERLY KAY Name:Kay Scheller Name:Kay Sheller
Address:PO BOX 95 Address:917 Webster Ave Address:917 Webster Ave
City,State Zip:MUKILTEO,WA 98275 City,State Zip:Mukilteo,WA 98275 City,State Zip:Mukilteo,WA 98275
Phone:425-280-7194 Phone:425-583-4201 Phone:425-583-4201
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Name: Name:
Address: Address:
City,State,Zip: City,State,Zip:
Phone: Phone:
LIC#: EXP: LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Residential Mechanical CODE YEAR: 2015
STORIES: CONST.TYPE:
DWELLING UNITS: 1 OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED
THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO
WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1I0/IRC1I0.
SALES TAX NOTICE:Sales tax _ng to cons ruction and construction materials in the Cily of Arlington must be reported on your sales tax return form
n Wed i of Arlingto
,��
Sign re Prin 'amc I :ate Released By bate
CONDITIONS
Approved as submitted. See attached Sediment Trap Detail 408.4 for required installation details.
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY
CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
1/11/2017 Gas Outlets Base Fee 1 to 5 $10.00
1/11/2017 Mechanical Fee(Enter Fixture Fee) $25.00
1/11/2017 Mechanical Permit Base Fee $25.00
1/11/2017 Processing/Technology Fee $25.00
Total Due: $85.00
Total Payment: $0 00
Balance Due: $85.00
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
GAS PIPING INSTALLATIONS
SECTION 407(IFGC) TO GAS SUPPLY IF BRANCH
PIPING SUPPORT CONNECTS TO APPLIANCE
OR TO APPLIANCE IF
407.1 General. Piping shall be provided with support in BRANCH CONNECTS TO GAS SUPPLY
accordance with Section 407.2.
407.2 Design and installation. Piping shall be supported
with metal pipe hooks,metal pipe straps, metal bands, metal
brackets, metal hangers or building structural components,
suitable for the size of piping, of adequate strength and qual-
ity, and located at intervals so as to prevent or damp out
excessive vibration. Piping shall be anchored to prevent
undue strains on connected appliances and shall not be sup-
ported by other piping. Pipe hangers and supports shall con-
form to the requirements of MSS SP-58 and shall be spaced
in accordance with Section 415. Supports, hangers and
anchors shall be installed so as not to interfere with the free TEE
expansion and contraction of the piping between anchors.All
parts of the supporting equipment shall be designed and
installed so they will not be disengaged by movement of the
supported piping.
SECTION 408 (IFGC) NIPPLE
OF ANY
DRIPS AND SLOPED PIPING LENGTH
408.1 Slopes. Piping for other than dry gas conditions shall
be sloped not less than `/4 inch in 15 feet (6.3 mm in 4572
mm)to prevent traps.
408.2 Drips.Where wet gas exists,a drip shall be provided at CAP—
any point in the line of pipe where condensate could collect.
A drip shall also be provided at the outlet of the meter and FIGURE 408.4
shall be installed so as to constitute a trap wherein an accu- Method of Installing a tee fitting sediment trap
mulation of condensate will shut off the flow of gas before
the condensate will run back into the meter.
408.3 Location of drips. Drips shall be provided with ready SECTION 409 (IFGC)
access to permit cleaning or emptying. A drip shall not be SHUTOFF VALVES
located where the condensate is subject to freezing. 409.1 General.Piping systems shall be provided with shutoff
408.4 Sediment trap. Where a sediment trap is not incorpo- valves in accordance with this section.
rated as part of the appliance, a sediment trap shall be 409.1.1 Valve approval. Shutoff valves shall be of an
installed downstream of the appliance shutoff valve as close approved type; shall be constructed of materials compati-
to the inlet of the appliance as practical. The sediment trap ble with the piping; and shall comply with the standard
shall be either a tee fitting having a capped nipple of any that is applicable for the pressure and application, in
length installed vertically in the bottommost opening of the accordance with Table 409.1.1.
tee as illustrated in Figure 408.4 or other device approved as 409.1.2 Prohibited locations.Shutoff valves shall be gro-
an effective sediment trap. Illuminating appliances, ranges, hibited in concealed locations and furnace plenums.
clothes dryers,decorative vented appliances for installation in
vented fireplaces, gas fireplaces, and outdoor grills need not 409.1.3 Access to shutoff valves. Shutoff valves shall be
be so equipped. located in places so as to provide access for operation and
shall be installed so as to be protected from damage.
TABLE 409.1.1
MANUAL GAS VALVE STANDARDS
APPLIANCE SHUTOFF OTHER VALVE APPLICATIONS
VALVE APPLICATION UP UP TO 2 psig UP TO 5 psig UP TO 125 psig
VALVE STANDARDS TO'/zpsig PRESSURE UP TO'/Zpsig PRESSURE PRESSURE PRESSURE PRESSURE
y ANSI Z21.15 X
ASME B 16.44 X X Xa Xb —
ASME B 16.33 X X X X X
For SI: 1 pound per square inch gauge=6.895 kPa.
a. If labeled 2G.
b. If labeled 5G.
74 2012 INTERNATIONAL FUEL GAS CODE®
I
Permit Information
Date 1/11/2017
Permit Number 1282
Project Name Schaller
Applicant Name Kay Scheller
Applicant Address 917 Webster Ave
City,State,Zip Mukilteo,WA 98275
Contact Gregory Zartman
Phone 425-583-4201
Email harleyguy4069@gmail.com
Permit Type Residential Mechanical
Site Address 522 E 3rd Street
Valuation 0.00
Status Applied
Permit Issued
Permit Expires
Square Feet 0
Type of Construction/Occupancy Load
Number of Stories 0
Proposed Use Install gas heater
Assigned To Kristin Foster
Property Information Owner Information
Parcel#:00455400101901 SCHELLER BEVERLY KAY
SCHELLER BEVERLY KAY PO BOX 95
522 E 3RD ST MUKILTEO,WA 98275
425-280-7194
Contractors
Contractor Name Primary Contact Phone Email Contractor Type License License#
Kay Sheller JGregory Zartman 125-583-4201 11harleyguy4069@ mail.com PPLICANT
Fees
Fee Description Notes Amount
Mechanical Permit Base Fe 322.10.00.001 $25.0
Processing/Technology eo 341.43.00.021 $25.00
Total $50.0
Uploaded Files Upload File
Date I File I Uploaded By I i
RESIDENTIAL MECHANICAL
PERMIT APPLICATION
Department of Community&Economic Development
City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551
THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND
OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION
AND INCLUDE ALL INFORMATION.
Project Address: j z Z. E 3 't lAt <Z IJ A,
Project Description: C-As
Owner:
Address: 7/ 7 f.✓&6 5 4-c City: l �� State: (A)A-Zip Code: 9 5'2- 7S
Phone: y Z - Z �o -7< q v z�=S'�3 - `Email: l�Lt�H K:( �'�� �,�c�y l7 Cod.,cats
Applicant:
Address: 5 /Z eC 3 Z City: 1A 2 �'-- """State: w�14- Zip Code: ?zL 3
Phone: y 2- 5J` 5 17/Z_0 Email: n%�-�f�� v•�.� Nv��� GrrYt.,,�.�� Cv1-7
CONTRACTOR INFORMATION
Contractor Name: v\ 7 e �- `� C2(-J "V C_)
Address: City: State: Zip Code:
License Number: Expiration:
Phone: L Z 5` 5-P 3 _ L�Zol Email: �r4-de 2 yuy Ll0 PI/L,, -Cry
STAFF USE ONLY
Permit#: Accepted by: Date:
6/16LP Page 1 of 2
c��Y °'� RESIDENTIAL MECHANICAL
z PERMIT APPLICATION
�lf'VG�O Department of Community&Economic Development
City of Arlington • 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551
SELECT ALL PROPOSED APPLIANCES
[J' Furnace (80+) Model# AFUE
�] Heat Pump Model# AFUE HSPE
❑. AC Unit Model# SEER
l� Freestanding Stove 0! Fire Place Insert 0! Outdoor BBQ
] Gas Piping 0 Solid-Fuel Appliance 11`—"Other
Gas Piping Information
Not Applicable: l]
Pipe Material:
Pipe Size:
Distance from Meter to Furthest Appliance.
Total BTU's of all Appliances:
• New gas piping requires a pressure test hooking to any appliance
• Sediment traps(drips) are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
• Proper Combustion air and venting required for all appliances
• A shut-off valve is required within 6 feet of all appliances
Applicant Signature: Date:
Applicant Printed Name:
I hereby certify that the above information is correct and that the construction, installation for the above mentioned
property will be in accordance with the applicable laws of the City of Arlington and the State of Washington.
6/16LP Page 2 of 2
t
COMMERCIAL MECHANICAL
PRESSURE PIPING INFORMATION
Department of Community& Economic Development
City of Arlington•.18204 59th Ave NE•Arlington, WA 98223• Phone(360)403-3551
If gas piping will be installed, this form is required in addition to a Commercial Mechanical Permit Application
Pipe Material:
Inlet Pressure:
Pressure Drop:
Specific Gravity-
Pressure Piping Schematic
Show Pipe Size(s)and Length(s)from meter to all appliances.
❑ Scale or ❑ Not to Scale
NOTE: any
interior
pressure
regulators
must be
indicated
NOTE: drip
A^ legs/sediment
traps are
required at all
appliances
unless
integrated in
the listed
appliance
I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-
described property will be in accordance with the laws, rules and regulation of the State of Washington.
Applicants Signature Date
Print Applicants Name
� -
I
I
i
A 40
VENT-FREE GAS WALL I
HEATER
OWNER'S OPERATION AND
( INSTALLATION MANUAL -
BLUE FLAME MODELS
BWH30NLTE-2
(Re
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable va-
pors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
o Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
@ department.
C — Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
®WARNING: This appliance is equipped for Natural and
Propane gas.Field conversion is not permitted other than
between natural or propane gases.
Questions,problems,missing parts?
Before returning to your retailer,call our customer service department at
1-800-229-5647,8:00 am-4:30 pm EST,Monday through Friday
_ :i
t
"' r
THIS GUIDE SH06ILD ONLY
3CONNECTING TO GAS SUPPLY
Never connect heater directly to the gas supply. This heater requires an external regulate
and/or gas meter(not supplied). Gas suppliers provide external regulators and/or gas me
ters. Do not over tighten gas connections.
Use only new, black iron or steel pipe. Internally tinned copper tubing may be used in certa
areas.Check your local codes.Use pipe of 1/2"diameter or greater to allow proper gas volurr
to heater. If pipe is too small,undue loss of pressure will occur.
Apply pipe joint sealant lightly to male threads. Pipe joint sealant should be resistant to tl-
actions of Liquid Propane Gas and Natural Gas. Prevent excess sealant from going into tr
pipe. Excess sealant in the pipe could result in clogged heater valves. Pipe joint sealant mE
not be used on flexible connectors. Check manufacturer's instructions.
NATURAL GAS MODELS:
Check your gas line pressure before connecting heater to gas line. Gas line pressure mu
be no greater than 10"of water.If gas line pressure is higher,heater regulator damage cou
occur. Never connect heater to private (non-utility) gas wells. This is commonly known e
wellhead gas.
LIQUID PROPANE GAS MODELS:
Note:A minimum 100 lb. LP cylinder/tank must be used. 20 lb. (gas grill style) tank
cannot be used.
The installer must supply an external regulator. The external regulator will reduce incoming ge
pressure.You must reduce incoming gas pressure to between 11"and 14"of water. If you do n,
reduce incoming gas pressure,heater regulator damage could occur.
Install sediment trap in supply line. Place sediment trap where it is within reach for cleaning.Pla(
sediment trap where trapped matter is not likely to freeze.A sediment trap traps moisture and coi
taminants.This keeps them from going into the heater controls. If the sediment trap is not installe
or is installed incorrectly,the heater may not run properly.
Complete Natural Gas Set Up Guide Complete Liquid Propane Set Up Guide
Vent-Free
Heating Products } Vent-Free
„INNi Heating Products
nulllll{H��N"
fT y 112"Male Flare x 318"Male Fitting
112"Male Flare x 318"Male Fitting
\ 22"Flexible
Connector 2-Stage Adjustable
Regulator Required
c
22"Flexible Connector MCO
�- ,)
112"Brass Minimum 100 lb.Liquid
—Equipment Propane Tank Required
Tee Joint Shutoff Valve o
c Reducer
Bushingto
112"Brass Equipment 118"NPT
ShutoffVatve -- ' 1r2"Inlet Pipe
\ 118"NPT, �Fom Gas Meter
Plug Tap or 2-Slage Regulator
112"Existing Gas (I,W.C.to
Line From Gas Meter rice Joint— 14"W.C.Pressure)
(5"W.C.to 10.5"W.C\ Sadl P n1
Pepe
Pressure) Nipple 13"Minimum
Gap
Actual Product May Vary from Illustration
4CHECKING GAS CONNECTIONS
Usinq Leak Detection Solution or a mixture of liquid soap and water. test all aaS Dining an
Permit#: 1282
Permit Date: 0l/1l/17
Permit Type: RESIDENTIAL MECHANICAL
Project Name: Scheller
Applicant Name: Kay Scheller
Applicant Address: 917 Webster Ave
Applicant, City, State, Zip: Mukilteo,WA 98275
Contact: Gregory Zartman
Phone: 425-583-4201
Email: harleyguy4069@gmail.com
Scope of Work: Install gas heater
Valuation: 0.00
Square Feet: 0
Number of Stories: 0
Construction Type:
Occupancy Group:
ID Code:
Permit Issued: 0l/11/2017
Permit Expires:
Form Permit Type:
Status: LASERFICHE
Assigned To: Kristin Foster
Property
Parcel# Address Legal Description Owner Name Owner Phone Zoning
00455400101901 522 E 3RD ST SCHELLER 425-280-7194 111 Single Family
BEVERLY KAY Residence-Detached
Contractors
Contractor Primary Contact Phone Address Contractor Type License License
Kay Scheller Gregory Zartman 425-583-4201 917 Webster Ave APPLICANT
Inspections
Date Inspection Type Description Scheduled Date Completed Date Inspector Status
01/13/2017 R09.GAS PIPING 01/11/2017 BUILDING Approved
ROUGH-IN
Plan Reviews
Date Review Type Description Assigned To Review Status
O1/11/2017 RESIDENTIAL BUILDING
MECHANICAL
Fees
Fee Description Notes Amount
Mechanical Base Permit Fee $25.00
Processing/Technology $25.00
Gas Piping/Units Enter#of units $10.00
Mechanical Fee(Enter Fixture Fee) $25.00
Total $85.00
Attached Letters
Date Letter Description
O1/11/2017 Building Permit
Payments
Date Paid By Description Payment Type Accepted By Amount
O1/11/2017 cash $85.00
Outstanding Balance $0.00
Uploaded Files
Date File Name
O1/11/2017 2045689-1282 Issued Permit.pdf