HomeMy WebLinkAbout3310 SMOKEY POINT DR_bld6809_2026 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 3310 SMOKEY POINT DR Permit#: 6809 Parcel#:00645300001300 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:adding 8 heads and shortening 8 heads Valuation:6435.00 CONTRACTORkh BLINKROCK TECHNOLOGIES INC Burns Fire Protection Systems,Inc. Burns Fire Protection Systems 13274 ASH WAY UNIT F3 PO Box 1110 PO Box 1110 EVERETT,WA 98204 Granite Falls Granite Falls,WA 98252 3606912235 360-691-2235 LIC:603 467 812 EXP:03/31/2026 LIC:BURNSFP841DU EXP:04/14/2026 LIC:86528 EXP:12101/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION - PERMIT TYPE: FIRE SPRINKLER CODE YEAR: 2021 STORIES: 1 CONST.TYPE: IA DWELLING UNITS: OCC GROUP: A-1;Assembly BUILDINGS: OCC LOAD: - PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordnance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC I10/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 11/19/2025 11/19/2025 A aft Sijnal/cure Date Building Official Date CONDITIONS Adhere to approved plans.Permit shall be onsite for inspections. Call for inspections. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. JEEW PERMIT FEES - Date Description Fee Amount 11/19/2025 Web Only-Fire System Plan Review $200.00 11/19/2025 Processing/Technology $25.00 11/19/2025 Fire Sprinkler System $225.00 Total Due: $450.00 Total Payment: S450.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail 4 27'0". .6.0"Col 61711 C t ♦ Classroom 5 • Classroom 4 Classroom 3♦ X 510 sq It= 418 sq ft= 418 sq It= Z-jZ Cla room 1 N 14 kids r 11 kids 11 kids 324 sq ft• • 420'0". 9ki s 424'0" 420'0". - '0.'� �1 .2"� o 13'7". ♦ 420'0". eo X Classroom 5 pre-school ca 26 kid ft p • = kids 11 adults 82 kids fo Total people 93 eople \ / L/ 421'9„ .11 '. _♦ 413'6". 426'10". Teacher o Ofr,Oe Lounge 435 6q ft v 13 people Stage 4 26'8". Alf � Electrical fit Classroom 150 sq ft ♦ Alf 18 kids 'v 2adults ry 4T0". G429'4" - 1I11 480'0". A�7 A N ♦ Toddlers Storage ��I Auditorium T N 500 sq ft 340 caoacity o • 14 kids P 2 adults v A Cl Ell =Kitchen G Vie' • .24'o'. 4 adults ) 414'8 R O • ♦ +ill ♦11 Sound 427'4"1 Toddlers m Classroom 11 v 468 sq ft 390 sq It N 13 kids • 11 kids Cry room D 2 adults 1 adult Storage Lighting Tech 416'0".Ir Daycare capacity 15 adults C o Toddlers 101 kids ♦ Total building capacity City of Arlington 5zo agof4° $ 561 people Building Department 14 kids 2 adults APPROVED storage 440 0' Kevin Olander- 11/18/2025 After School kids care 42r o 0 710 sq ft=20 kids Present No changes authorized unless approved by Office v CoaeeBar front the Building Official T Entry CBabies ♦ ♦ acher .1210". �I 560 sq w Nt , 11 babies of unge 3 adults 428'0". Adel $-- • — !b5° Po.dant �( � I65 E1tu'�1n1 Ind fJ Life 360 Church W E 3310 Smokey Pt Dr Arlington, WA 98223 Site: Drawing: Project: Dzawn: Notes: AcmeHlllldera Corp 9910 Administration Sq. 901506 0000416 Name 1234 Oak Road Tit e. Scale: Date: Rev: Yorktown, NY 10598 12G Floor Office Remodel 1/4":1'0" 01/30/2017 A Burns Fire Protection Systems, Inc. P.O. Box 1110 Granite Falls, WA 98252 City of Arlington PH: (425) 388-0124 Building Department APPROVED Kevin Olander- 11/18/2025 No changes authorized unless approved by the Building Official Life 360 Church -TI 3310 Smokey Point Dr Arlington, WA 98223 Item No DESCRIPTION MANUFACTURER MFG. NO. FINISH REMARKS Sprinkler Head Tyco TY3211 165' Pendent Storage Cabinet FPPI Red Steel Pipe Bull Moose Sch 10/40 1 Eddy Flow Blk Sammy Screw All Buildex Hangers Caddy Seismic Bracing Afcon AF730 Sway Brace Afcon AF001 Grooved Coupling Victaulic 009H Orange Grooved Fitting Victaulic Orange Mech Tee Tyco 730 Orange Threaded Fittings Shurjoint Blk CO® Worldwide www.tyco-fire.com Contacts Series TY-L - 5.6 and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage The Series TY-L Recessed Pendent IMPORTANT Sprinkler, where applicable, is Refer to Technical Data Sheet intended for use in areas with a fin- TFP2300 for warnings pertaining to ished ceiling. It uses a two-piece Style regulatory and health information. 20(1/2 in. NPT)Recessed Escutcheon. The recessed escutcheon provides Always refer to Technical Data Sheet TFP700 for the "INSTALLER 1/4 in. (6,4 mm) of recessed adjust- WARNING" that provides cautions ment or up to 1/2 in. (12,7 mm) of total with respect to handling and instal- adjustment from the flush pendent lation of sprinkler systems and com- position. The adjustment provided by ponents. Improper handling and the recessed escutcheon reduces the installation can permanently damage accuracy to which the fixed pipe drops a sprinkler system or its compo- to the sprinklers must be cut. nents and cause the sprinkler to fail Corrosion-resistant coatings, where to operate in a fire situation or cause applicable, are utilized to extend the it to operate prematurely. life of copper alloy sprinklers beyond what would be obtained when exposed / Scan the QR code or enter the URL to corrosive atmospheres. Although a web browser a access the most corrosion-resistant coated sprinklers in in a date electronic version of this have passed the standard corrosion document. Data rates may I tests of the applicable approval agen- y apply.y. cies, the testing is not representative �■,,1 y7 of all possible corrosive atmospheres. '■� Consequently, it is recommended 1 that the end-user be consulted about ■'�, the suitability of these coatings for ■ any given corrosive environment. The \,I effects of ambient temperature, con- The owner is responsible for main- �.��.� centration of chemicals, and gas/ taining their fire protection system chemical velocity, should be consid- and devices in proper operating con- ■ ered as a minimum,along with the cor- dition. Contact the installing contrac- } '•1 rosive nature of the chemical to which for or product manufacturer with any ■ the sprinklers will be exposed. questions. 511 J An intermediate level version of the NFPA 13 prohibits installation of 112 in. ■ Series TY-L Pendent Sprinkler can be NPT sprinklers with K-factors greater docs.jci.com/tycofire/tfp110 obtained by utilizing the Series TY-L than 5.6 in new construction. They are Pendent Sprinkler in combination with intended for retrofit in existing sprinkler the Model S Shield. systems only. General Description � Sprinkler p The Series TY-L 5.6 and 8.0 K-fac- The TYCO Series TY-L 5.6 and for Upright, Pendent, and Recessed Identification 8.0 K-factor Upright, Pendent, Pendent Sprinklers described herein Number (SIN) and Recessed Pendent Sprin- must be installed and maintained in klers described herein are stan- compliance with this document, as well as with the applicable standards TY3111 . . . Upright 5.6K, 1/2 in. NPT Bard response, standard coverage, of the NATIONAL FIRE PROTECTION TY3211 . . .Pendent 5.6K, 1/2 in. NPT solder type spray sprinklers. They are ASSOCIATION (NFPA), in addition to TY4111 . . . Upright 8.0K, 3/4 in. NPT designed for use in light, ordinary, and the standards of any other authorities TY4811 . . . Upright 8.0K, 1/2 in. NPT extra-hazard commercial o having jurisdiction. Failure to do so Note: cies such as banks, hotels, shopping p may impair the performance of these TY3111 is a re-designation for S1 800 and G311 1. malls,factories, refineries, and chemi- devices. TY3211 is a re-designation for S1801 and G3112. cal plants. TY4111 is a re-designation for S1810 and G3101. • TY4811 is a re-designation for S1805. Page 1 of 6 JUNE 2025 TFP110 TFP110 Page 2 of 6 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Ejection 5 - Strut is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Sealing Spring 6 - Hook Deflector. special request. PLATE SEATING Button 4 - Fusible 7 - Deflector* SURFACE Element 1 WRENCH 2-5/8" AREA 2 (66,7 mm) 7/16" 72-5/8" (11,1 mm) NOMINAL 2" STYLE 20 5 MAKE-IN 1 (50,8 mm) RECESSED ESCUTCHEON 6 if 1/2" NPT** WRENCH 2-7/8"(73,0 mm)DIA. - 7* FLANGES UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION FIGURE 1 SERIES TY-L UPRIGHT(TY3111)AND PENDENT(TY3211)SPRINKLERS, 5.6 K-FACTOR, 112 IN. NPT 7* 1 - Frame 3 - Ejection 5 Strut 6 2 - Sealing Spring 6 Hook Button 4 - Fusible 7 - Deflector* 1/2 5 Element 2-11/16" (12,7 mm) *Temperature rating is indicated on (68,3 mm) NOMINAL WRENCH 3 _4 Deflector. MAKE-IN FLANGES ** Pipe thread connections per ISO 7-1 1 WRENCH 2 can be provided on special request. 3/4" AREA NPT** UPRIGHT CROSS SECTION 1 FIGURE 2 SERIES TY-L UPRIGHT(TY4111)SPRINKLERS, 8.0 K-FACTOR, 314 IN. NPT 7* 1 - Frame 3 - Ejection 5 Strut 6 2 - Sealing Spring 6 Hook Button 4 - Fusible 7 Deflector* 7/16" 5 Element 2-5/8" (11,1 mm) *Temperature rating is indicated on (66,7 mm) NOMINAL WRENCH 3 _4 Deflector. MAKE-IN FLANGES ** Pipe thread connections per ISO 7-1 1 WRENCH 2 can be provided on special request. �1/2" AREA NPT** 1 UPRIGHT CROSS SECTION FIGURE 3 SERIES TY-L UPRIGHT(TY4811)SPRINKLERS, 8.0 K-FACTOR, 112 IN. NPT TFP110 Page 3of6 Frame Sprinkler Finish K-Factor Type Temperature Color Wax Code Natural Brass Chrome Plated Coated 165°F(74°C) Unpainted 1,2,3 Upright(TY3111) 212°F(100°C) White 280°F(138°C) Blue 4 5.6 165°F(74°C) Unpainted 112in. 1,2,3 1,2,3 NPT Pendent(TY3211) 212°F(100°C) White 280°F(138°C) Blue 4 Recessed Pendent 165°F(74°C) Unpainted (TY3211 w/Style 20) 212°F(100°C) Wh 4 ite NOTES: 1. UL Listed 3. FM Approved 2. C-UL Listed 4. Not Available(N/A) TABLE A SERIES TY-L 5.6 K-FACTOR SPRINKLERS LABORATORY LISTINGS AND APPROVALS Frame Sprinkler Finish K-Factor Type Temperature Color Wax Rating Code Natural Brass Chrome Plated Coated 8.0 165°F(74°C) Unpainted 1,2,3 3/4 in. Upright(TY4111) 212°F(100°C) White 1,2,3 4 NPT 280°F(138°C) Blue 4 8.0 165°F(74°C) Unpainted 1,2,3 1/2 in. Upright(TY4811) 212°F(100°C) White 1,2,3 NPT 280°F(138°C) Blue 4 NOTES: 1. UL Listed 3. FM Approved 2. C-UL Listed 4. Not Available(N/A) TABLE B SERIES TY-L 8.0 K-FACTOR SPRINKLERS LABORATORY LISTINGS AND APPROVALS Discharge Coefficient Physical Characteristics Technical K=5.6 gpm/psi/ (80,6 Lpm/bar'/2) Frame .............................Brass K=8.0 gpm/psi'/,(115,2 Lpm/bar'/,) Sealing Button ........... Bronze w/TEFLON Data Ejection Spring.............. Stainless Steel Temperature Ratings Strut ............................MONEL Approvals See Tables A and B Hook......................Bronze/MONEL UL and C-UL Listed Deflector..........................Bronze FM Approved Finishes Fusible Element .............Solder,Copper, Sprinkler:See Tables A and B Stainless Steel Note: For complete approval information including corrosion resistant status, see Recessed Escutcheon:White Coated, Tables A and B. Chrome Plated,or Brass Plated Maximum Working Pressure 175 psi(12,1 bar) TFP110 Page 4of6 7/16 1/8" 2-7/8" DIA. 1/2"(12,7 mm) Step 2. With pipe thread sealant (11,1 3,2 mm) (73,0 mm) 1/4"(6,4 mm) applied to the pipe threads, hand- tighten the sprinkler into the sprinkler FACE OF 2-1/4" DIA. MOUNTING fitting. SPRINKLER (57,2 mm) PLATE Step 3. Tighten the sprinkler into the FITTING sprinkler fitting using only the W-Type 1/8 9 Sprinkler Wrench as shown in Figure (3,2 mm) 5. For wax coated sprinklers, use an 8 -- —= 1 or 10 in. adjustable Crescent wrench. Apply the W-Type 9 Sprinkler Wrench to the wrench area as shown in Figures MOUNTING 1 1, 2, or 3, or as applicable, apply the SURFACE 1-3/4" (44,5 mm) adjustable Crescent wrench to the 1-112" (38,1 mm) wrenching flanges. CLOSURE TY L ! Wax Coated Sprinklers When installing wax-coated sprinklers FIGURE 4 with the adjustable Crescent wrench, SERIES TY-L(TY3211)RECESSED PENDENT SPRINKLER ASSEMBLY take care to prevent damage to the WITH TWO-PIECE 112 IN. TOTAL ADJUSTMENT wax coating on the sprinkler wrench STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 112 IN. NPT flats or frame arms and, consequently, exposure of bare metal to the corrosive environment: WRENCH Open the jaws of the wrench suffi- RECESS\ ciently wide to pass over the wrench WRENCH flats without damaging the wax RECESS coating. • Before wrench tightening the sprin- kler,adjust the jaws of the wrench to �� • just contact the sprinkler flats. After wrench tightening the sprin- kler, loosen the wrench jaws before FIGURE 5 FIGURE 6 removing the wrench. W-TYPE 9 SPRINKLER W-TYPE 10 RECESSED After Installation WRENCH SPRINKLER WRENCH After installation, complete the following: Operation Installation • Inspect the sprinkler wrench flats and frame arms and retouch(repair) A copper tube sealed by two stainless The TYCO Series TY-L 5.6 and the wax coating whenever the coat- steel balls holds a fusible alloy. When 8.0 K-factor Upright, Pendent, and ing has been damaged and bare the rated temperature is reached, the Recessed Pendent Sprinklers must metal is exposed. alloy melts and the balls are forced be installed in accordance with this Retouch the wax coating on the toward each other. This releases the section. wrench flats by gently applying a tension mechanism and allows the General Instructions heated 1/8 in. diameter steel rod to sprinkler to operate. A leak tight 1/2 in. NPT sprinkler joint the damaged areas of the wax, to should be obtained with a torque of smooth it back over areas where Design 7 lb-ft to 14 lb-ft(9,5 N•m to 19,0 N•m). bare metal is exposed. A leak- tight 3/4 in. NPT sprinkler joint Inelm Criteria should be obtained with a torque of 10 lb-ft to 20 lb-ft (13,4 N•m to Only retouching of the wax coating The TYCO Series TY-L 5.6 and 26,8 N•m). Higher levels of torque may applied to the wrench flats and frame 8.0 K-factor Upright, Pendent, and distort the sprinkler inlet and cause arms is permitted, and the retouching Recessed Pendent Sprinklers are leakage or impairment of the sprinkler. is to be performed only at the time of intended for fire protection systems the initial sprinkler installation. designed in accordance with the stan- Do not attempt to compensate for dard installation rules recognized by insufficient adjustment in the escutch- The steel rod should be heated only to the applicable Listing or Approval eon plate by under- or over-tightening the point it can begin to melt the wax, agency, such as the UL Listing based the sprinkler. Re-adjust the position of and appropriate precautions need to be on the requirements of NFPA 13 and FM the sprinkler fitting to suit. taken when handling the heated rod to Approval based on the requirements of prevent the installer from being burned. FM Loss Prevention Data Sheets. Use Series Upright and Pendent If attempts to retouch the wax coating Sprinkleersrs Installation p g only the style 20 recessed escutcheon, The Series TY-L Pendent and Upright with complete coverage are unsuc- as applicable, for recessed pendent cessful,additional wax can be ordered installations. Sprinklers must 11 installed u ions: in the form of a wax stick, the end of dance with the following instructions: which is color coded. Only the correct Step 1.Install pendent sprinklers in the color coded wax is to be used, and pendent position. Install upright sprin- retouching of wrench flats and frame klers in the upright position. arms is only permitted at the time of initial sprinkler installation. TFP11O Page 5of6 P/N 53 XXX X XXX SIN SPRINKLER TEMPERATURE FINISH RATING 111 5.6K UPRIGHT(1/2 in. NPT) TY3111 1 NATURAL BRASS 165 165°F(74°C) 112 5.6K PENDENT(1/2 in.NPT) TY3211 6 WAX COATED' 212 212°F(100°C) 101 8.OK UPRIGHT(3/4 in. NPT) TY4111 9 CHROME PLATED2 280 280°F(138°C) 106 8.OK UPRIGHT(1/2 in.NPT) TY4811 NOTES: 1. Available for TY3111 and TY3211 5.6K sprinklers in 165°F(74°C)and 212°F(100°C)temperature ratings only. 2. Not available for TY4111 8.OK sprinkler. TABLE C SERIES TY-L PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION With the steel rod heated as previ- Care and Frequent visual inspections are rec- ously described, touch the rod to the ommended to be initially performed area requiring additional wax with the Maintenance for corrosion resistant coated sprin- rod angled downward, and then touch klers, after the installation has been the wax stick to the rod approximately The TYCO Series TY-L 5.6 and completed,to verify the integrity of the 112 in. (12,7 mm) away from the area 8,0 K-factor Upright, Pendent, and corrosion-resistant coating.Thereafter, requiring retouching. The wax will melt Recessed Pendent Sprinklers must be annual inspections per NFPA 25 should and run down onto the sprinkler. maintained and serviced in accordance suffice; however, instead of inspecting Series TY-L Recessed Pendent with this section. from the floor level,a random sampling Sprinklers Installation Before closinga fire protection system of close-so visual inspections should The Series TY-L Recessed Pendent y ex made in as to better determine the main control valve for maintenance exact sprinkler condition and the long- Sprinkler must be installed in accor- work on the fire protection system that term integrity of the corrosion resistant dance with the following instructions: it controls,permission to shut down the coating, as it may be affected by the Step 1. After installing the style 20 affected fire protection system must be corrosive conditions present. mounting plate,as applicable,over the obtained from the proper authorities sprinkler threads and with pipe thread and all personnel who may be affected The owner is responsible for the sealant applied to the pipe threads, by this action must be notified. inspection,testing,and maintenance of hand-tighten the sprinkler into the their fire protection system and devices 9 p Absence of an escutcheon, which is in compliance with this document, as sprinkler fitting. used to cover a clearance hole, may well as with the applicable standards Step 2. Tighten the sprinkler into the delay the time to sprinkler operation in of the NATIONAL FIRE PROTECTION sprinkler fitting using only the W-Type a fire situation. ASSOCIATION such as NFPA 25, in 10 recessed sprinkler wrench as shown Sprinklers that are found to be leaking addition to the standards of any other in Figure 6. Apply the wrench to the or exhibiting visible signs of corrosion authorities having jurisdiction. Contact sprinkler wrenching flanges as shown must be replaced. the installing contractor or product in Figures 1. manufacturer with any questions. Automatic sprinklers must never be Step 3. After the ceiling has been painted, plated, coated or otherwise It is recommended that automatic installed or the finish coat has been altered after leaving the factory. Modi- sprinkler systems be inspected,tested, applied, slide on the style 20 closure fied or over-heated sprinklers must be and maintained by a qualified Inspec- over the Series TY-L Recessed Pendent replaced. Care must be exercised to tion Service in accordance with local Sprinkler and push the closure over the avoid damage to the sprinklers before, requirements and/or national codes. mounting plate until its flange comes in during, and after installation. Sprin- contact with the ceiling. klers damaged by dropping, striking, wrench twist/slippage,or the like, must be replaced. TFP110 Page 6 of 6 Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-L (specify SIN), (specify K-factor), (specify Upright, Pendent,or Recessed Pendent)Sprin- kler, Standard Response, Standard Coverage,(specify)temperature rating, (specify)finish or coating, P/N (specify from Table C) Recessed Escutcheon Specify: Style (specify) Recessed Escutcheon, (specify material) with (specify")finish, P/N (specify*) 'Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 9 Sprinkler Wrench, P/N 560001849 Specify: W-Type 10 Sprinkler Wrench, P/N 560001948 Wax Sticks(for retouching wrench- damaged wax coating) Specify: Series TY-L Sprinklers, (specify color), color coded Wax Stick for retouching, (specify) temperature rated, P/N (specify): Red 165°F(74°C)....................560651155 Blue 212°F(100°C)and 280°F(138°C)....560651286 Note:Each waxstickis suitable forretouch- ing up to twenty-five sprinklers. The wax used for280oF(138°C)sprinklers is the same as for 212°F(100°C)sprinklers. Therefore, the 280°F(138°C)sprinkler is limited to the same maximum ceiling temperature as the 212°F(100°C)sprinkler, which is 150°F (65°C). 1467 Elmwood Avenue,Cranston,RI 029101 Telephone+1-401-781-8220 0 2025 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice.are JohnsonORO1 NATIONAL FIRE PROTECTION ASSOCIATION and NFPA registered tr of ademarks National Fire Protection Association; Contra MONEL and INCONEL are registered trademarks of Special Metal.Corporation; TEFLON I.a trademark of The Chemour,Company FC,LLC Spare Sprinkler Head Storage Cabinet 111S1S7r-_1L FPPI° Description Fire Protection Products, Inc. Spare Sprinkler Head Cabinets are designed to allow for spare sprinkler head storage as required by NFPA guidelines. The Spare Sprinkler Head Cabinets are available in six configurations. Three head, six head, six head ESFR, twelve head, twenty-four head and thirty-six head. All six styles are manufactured with "knockouts"to accommodate the most common size sprinklers. The shelf is located to allow for the storage of a typical sprinkler head wrench. Each cabinet is finished with a red enamel finish. Each spare head cabinet comes with a hinged door which remains closed to protect the spare sprinklers from the elements and features two holes on the back panel to allow for attachment to most surfaces utilizing the appropriate fasteners. Not intended for exposed or harsh environments. Installation Specifications Select the correct Spare Sprinkler Head Cabinet in accordance with the Material: Automatic Sprinkler Systems Handbook. As per the 1989 Edition the correct Painted Plain Steel number of spare sprinkler is as follows: Finish: 0-300 sprinklers, not less than 6; 300-1000, not less than 12; 1000 or more, Red enamel not less than 24. Stock of spare sprinklers shall include all types and ratings Styles: installed.* 3 Spare sprinklers, '/2 or 3/4 6 Spare sprinklers, '/2 or 3/4 6 Spare, ESFR, 1/2, 3/4 or 1" Once the correct Spare Sprinkler Head Cabinet has been selected, installation 12 Spare sprinklers'/2 or 3/ is accomplished by inserting the correct fastener in each of the two holes inside 24 Spare sprinklers the cabinet, securing the cabinet securely to the wall. The insert the correct 36 Spare sprinklers number and type of sprinklers in accordance with the "handbook". *Final determination is subject to approval by the AHJ. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+1 760 599-1168 +1 800 344-1822 FAX+1 800 344-3775 ©2012 Fire Protection Products,Inc. TT AT AT U BULL MOOSE® EDDY FLOW SPRINKLER PIPE SUBMITTAL DATA SHEET TUBE APPROVALS AND SPECIFICATIONS FINISHES AND COATINGS • ASTM A135, Grade A • Eddy Flow Sprinkler Pipe receives an OD mill coating of water-based • ASTM A795,Type E, Grade A paint which has corrosion protection expected with a painted carbon • Pressure rated to 300 psi steel product, i.e. it would be expected to resist corrosion for an • Underwriters Laboratories— extended and indefinite period in a clean and dry environment and, United States of America as environmental conditions deteriorate,the corrosion protection • Underwriters Laboratories—Canada would also diminish. • Factory Mutual • Eddy Flow Sprinkler Pipe (black) receives an ID mill coating of Eddy • NFPA-13 Guard II MIC preventative coating. EG2 has been tested at • NFPA-13R independent laboratories to resist bacterial growth and maintain • NFPA-14 minimal bacterial count after multiple flushes (25) of the pipe. • CIVIL DEFENSE APPROVAL— • Eddy Flow Sprinkler Pipe when Hot Dip Galvanized by ASTM A123 United Arab Emirates and supplied by Bull Moose Tube is UL listed and FM approved. • Made in the United States of America PRODUCT IDENTIFICATION • UL, ULC&FM listed for roll-groove, plain-end and welded joints for wet, dry, Every length of BUII Moose fire sprinkler pipe features large, easy-to- preaction and deluge sprinkler systems. read, continuous stenciling, clearly identifying the manufacturer,type • LEED v4 Certified of pipe,size,and length. mom 1.660 1.900 2.375 2.875 3.500 4.500 1.530 1.728 2.203 2.705 3.334 4,310 7 JEMPtVWe'11gJnT(10F1.222 1.844 2.330 2.809 3.361 4,968 Water Filled Weight(lb/ft) 2.019 2.860 3.982 5.299 7,144 11.290 C.R.R.* 1.98 3.44 2.78 1.66 1.00 1.00 Pieces per Lift 61 61 37 30 19 19 *Calculated using Standard UL CRR formula,UL Fire Protection Directory,Category VIZY U1 C U1 FM L SUBMITTAL INFORMATION Project Contractor Engineer Specification Reference Date System Type Locations Comments O Eddy Flow-Black Eddy Flow-Hot Dip Galvanized BULLT/[OOSETUBE. - 00 00 Schedule • and Schedule 40 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer Bull Moose Tube's Sch. 10 and Sch. 40 pipes are of quality pipe products. Our Schedule 10 and made to ASTM A135 and ASTM A795. These Schedule 40 are FM Approved and UL Listed (for U.S. products are typically supplied with our protective and Canada), even though these products do not coating but can be supplied without the coating so require separate approvals and listings. Bull Moose they can be hot-dip galvanized to meet FM Tube made the decision to have them approved and requirements for use in dry systems in accordance listed for your peace of mind. Our Sch. 10 and Sch. 40 with the zinc coating specifications of ASTM A795 or have been through the same rigorous testing as our ASTM A53. All Schedule 10 and Schedule 40 pipe other fine pipe products. has a pressure rating of 300 PSI. Schedule 10 Pipe Nominal .- Size (in) Nominal O.D. 1 1.315 1.097 1.41 Ibs/ft 91 1 1/4 1.660 1.442 1.81 Ibs/ft 61 1 1/2 1.900 1.682 2.09 Ibs/ft 61 2 2.375 2.157 2.64 Ibs/ft 37 2 1/2 2.875 2.635 3.53 Ibs/ft 30 3 3.500 3.260 4.34 Ibs/ft 19 4 4.500 4.260 5.62 Ibs/ft 19 Schedule 40 Pipe 116� Nominal Pipe Size (in) Nominal O.D. (in) 1 1.315 1.049 1.68 Ibs/ft 70 1 1/4 1.660 1.380 2.27 Ibs/ft 51 1 1/2 1.900 1.610 2.72 Ibs/ft 44 2 2.375 2.067 3.66 Ibs/ft 30 2 1/2 2.875 2.468 5.80 Ibs/ft 30 3 3.500 3.068 7.58 Ibs/ft 19 4 4.500 4.026 10.80 Ibs/ft 19 PIPE PREPARATION For proper operation,all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket,pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint,scale,dirt,chips,grease,and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly,causing leakage. Also,check the manufacturer's instructions for the specific fitting used. QiIZ 1819 Clarkson Road Foradditonal inforpmation, C �L usA Chesterfield, MO 63017 contact our salesperson (800)325-4467 today at(800)325-4467 or LISTED BULL MOOSE TUBE COMPANY FAX:(636)537-2645 (636)537-2600 in the USA, www.bullmoosetube.com or from Canada F M A UP- company e-mail: sales(c�bullmoosetube.com call(800)882-4666 APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 12/09 t t tllll &64mmys 20184019 � + Product Catalog Ap TABLE OF CONTENTS Sammys°for Wood .......................................................................................................................... 4 Sidewinder"for Wood....................................................................................................................... 5 Sammys Swivel Head" for Wood......................................................................................................5 Sammys°for Steel............................................................................................................................ 6 Sidewinder"for Steel........................................................................................................................ 7 Sammys Swivel Head'm for Steel....................................................................................................... 7 SammyX-PressO............................................................................................................................... 8 SammyX-Press SidewinderTM............................................................................................................ 8 SammyX-Press Swivel'm................................................................................................................... 9 Sammy X-Press It° Installation Tool ..................................................................................................9 Sammys°for Concrete................................................................................................................... 10 Sidewinder"for Concrete ................................................................................................................ 10 Sammys Swivel HeadT11 for Concrete................................................................................................11 Concrete/Wood Installation Kit........................................................................................................ 11 SammysToggleTM............................................................................................................................ 12 Dektite° Pipe Flashing..................................................................................................................... 12 Sammys X-Press° Pole Tool Kit...................................................................................................... 13 SammysPole TooITM......................................................................................................................... 13 Approvalsand Listings.................................................................................................................... 14 SpecialNotes .................................................................................................................................. 15 Warranty • Disclaimer of Warranty Proper fastener connection design takes in to account where and how fasteners are used.Allowance for special characteristics in materials,differences in materials,differences in types of materials being joined,unique or unusual environmental service or installation conditions and the safety factors required by anticipating normal or short term loading conditions must be considered.Due to possible differences in specifications,applications,and interpretation of results,purchasers and specifiers must make their own evaluation of the products,to determine the suitability of these products for intended use.All warranties of Buildex products,expressed or implied,including the warranties of merchantabilty and fitness for particular purposes are specifically excluded except for the following:Buildex will repair or replace any product which,within twelve months after sale by Buildex or its distributors,is found by Buildex to be defective in material or workmanship-normal wear and tear accepted.This is the sole warranty of Buildex and the sole remedy available to distributor or buyer.Buildex shall not be liable for any injury,loss or damage,direct,indirect,or consequential,arising out of the use of,or the inability to use,any Buildex product. INSTALLATION • • ' WOOD & STEEL INSTALLATION STEP INTO WOOD&STEEL: INSTALLATION STEP •' •MTO WOOD&STEEL: 1.Insert the appropriate nut driver into a 318"or 1/2°portable drill. 1.Insert the appropriate nut driver into a 318"or 112"portable drill. 2.Insert the SAMMYS®into the#14(black)nut driver(p/n 8113910).Drill 2.Insert the SAMMYS into the#14SW(red)nut driver(p/n 8114910).With drill should be in a vertical position. unit in a horizontal position and at a right angle to the structural member, begin installation. 3.Push the face of the nut driver tight to the member.Begin installation when the nut driver spins freely on the SAMMYS,stop drill and remove. 3.When the nut driver spins freely on the SAMMYS,stop the drill and remove. 4.The SAMMYS is now ready to receive 114"318",112"or metric all thread rod,bolt stock.(The 112"requires the#14SW red nut driver) 4.The unit is now ready to receive 114",318",M10,M8 or metric all thread rod or bolt stock. Note:When installing DSTR,follow the above instructions,then add retainer nut and torque to 20 inch lbs.for maximumpullout in purlin steel. Note:When installing SWDR,follow the above instructions,then add retainer nut and torque to 20 inch lbs.for maximum pullout in purlin steel. INSTALLATION • FOR CONCRETE INSTALLATION STEPS- =INTO CONCRETE: INSTALLATION STEPS = INTO CONCRETE: 1.Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 1.Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit,pre-drill the concrete member to a depth of 2"with a carbide tip bit,pre-drill the concrete member to a depth of 2"with a hammer/ hammer/rotary hammer drill set on impact mode. rotary hammer drill set on impact mode. 2.After pre-drilling has been completed,install the SLEEVE TOOL over 2.After pre-drilling has been completed,install the SLEEVE TOOL the bit(the bit should remain in the drill),and insert the#14(black) over the bit(the bit should remain in the drill),and insert the#14SW(red) nut driver(p/n 8113910)into the opposite end(see Vertical Installation nut driver(p/n 8114910)into the opposite end. note above). 3.Insert the SWC screw into the nut driver. 3.Insert the CST screw into the nut driver. 4.Place tip of screw into the pre-drilled hole,turn impact/drill unit to 4.Place tip of screw into the pre-drilled hole,turn impact/drill unit to drill drill mode and begin insertion.When the nut driver spins free on the mode and begin insertion.When the nut driver spins freely on the SWC screw,installation is complete.Stop and remove drill. CST screw,installation is complete.Stop and remove drill. 5.The SWC screw is ready to receive 114"318"or metric all thread rod 5.The concrete screw is ready to receive 114",318°112",or metric all or bolt stock. thread rod or bolt stock.(#14SW red nut driver used with 112"screw) Note:Use a 1200 maximum RPM drill for installation. Note:Use a 1200 maximum RPM drill for installation. Note:Do not install concrete screws while the drill unit is in impact mode— Note:Do not install concrete screws while the drill unit is in impact mode— doing so will destroy the pullout factor of the fastener doing so will destroy the pullout factor of the screw. SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. 3 To find a distdbutor near you,call 800-848-5611 SAMMYS° FOR WOOD SAMMYS' FOR WOOD - Vertical Application Application Product Features Not less than Wood Flooring 2"nominal width •No pre-drilling required. •Quick to install using the Sammy Not less than Nut Driver with an 18V cordless 3"nominal drill. thickness(2-1/2") (depth or side Wood Joist of vertical member) •Saves time from traditional - - - - - methods. Double Sheetrock Ceiling •Reduces installation costs. Assembled in the U.S.A. Composite/Truss Consult truss manufacturer for recommended installation point. *Pre-dtilfing may be required for GST N 25-380.Tool available on page 11. View our installation videos! OUT& Approvals Rod Part Model Screw Ultimate UL Test FM Test Box Case Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Gty Qty VERTICAL MOUNT 1/4" 8002957 GST 100 1/4 x 1" 210 (7/16"OSB) 25 125 670 (3/4"Ply) 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 L 3/8" 8007957 GST 10 1/4 x 1" 210 (7/16"OSB) 300 25 125 670 (3/4"Ply) 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 #14 Black 3/8" 8068925 GST 20-SS 1/4 x 2" 1760 (Fir) 850 25 125 Nut Driver v 3/8" 8009925 GST 25-380 3/8 x 2-1/2" 2113 (Fir) 1500 25 125 Part#8113910 tg 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) 1500 1475 25 125 _ 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25 125 1/2" 8015925 GST 3 1/4 x 3" 2275 (Fir) 25 125 #14 SW Red Nut Driver Part#8114910 If w � oHS ASSEMBLED U.S.A. SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. 0 SIDEWINDER@ FOR WOOD -Horizontal ApplicationApplication o Product„ 5 Not less than 2"nominal width •No pre-drilling required. (1-1/2")up to 3-1/2"pipe;not less than 3"(2-1/2")nominal width 4"&5'pipe •Quick to install using the Sammy Floor Joist Nut Driver with an 18V cordless Minimum 2-1/2"from bottom for drill/driver. branch lines.Minimum 3"from bot- tom for main lines.Exception:This •Saves time from traditional requirement shall not apply to 2"or methods. thicker nailing strips resting on top of steel beams. •Reduces installation costs. •Assembled in the U.S.A. :r View our installation videos! O YOUTUk HORIZONTALApprovals Rod Part Model Screw Ultimate UL Test Box Case Size Number Descriptions Shear(Ibs) Load(Ibs) Gty QtY . VIL 3/8" 8020957 SWG 10 1/4 x 1" 622 (Fir) 300 25 125 3/8" 8021957 SWG 20 1/4 x 2" 1725 (Fir) 1050 25 125 Q. 3/8" 8022925 SWG 25-380 318 x 2-1/2" 2249 (Fir) 1500 25 125 3/8"* 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 #14 SW Red Nut Driver Part#8114910 SAMMYS SWIVEL HEAD Tm FOR WOOD Swivel Application Application Product Features r..•an c.*00°.,,,.10", •Eliminates distortion of threaded rod. ", •Accommodates up to 3'%"x 12 pitch roof. •Allows 17°deflection from vertical. ..a •Saves time from traditional methods. •Reduces installation costs. �rre� •*. Assembled in the U.S.A.Approvals Rod Part Model Screw Ultimate UL Test Load FM Test Min Box Case • Size Number .• City e #14 Black SWIVEL MOUNT Nut Driver 3/8" 8139957 SH-GST 20 1/4 x 2" 1257(Fir) 1050 1475 25 125 Part#81139101 1903 Dim.Lumber 1500 33/8" 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1406 @ 45°off vertical 850 @ 45° 25 125 May require pre-drilling;consult joist manufacturer. Dim.Lumber #14 SH Orange ••will not swivel until installed with black nut driver. • Nut Driver Part#8273910 To find.distributor near y• 800-848-5611 SAMMYS® FOR STEEL SAMMYS' FOR STEEL - Vertical Application Application Product Features •Made with Teks®self-drilling fasteners- no pre-drilling required. •Installs into steel range from ` 20 gauge—1/2"thicknesses. �' •Saves time from traditional methods. •Reduces installation costs. •Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. •A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance,the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. ,► •Assembled in the U.S.A. P�►�.O�►JL� � View our installation videos! MuTube Approvals Rod Part Model Screw Ultimate ILL Test FM Test Min Max Box Case Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Thick Thick Qty Qty VERTICAL MOUNT 1/4" 8024957 DSTR 100* 1/4-20 x 1"TEKS 3 1510 (20 ga.) .036"-20 ga 3/16" 25 125 1/4" 8025957 DST 100 1/4-14 x V TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 1/4'. 8026957 DST 150 1/4-14 x 1-1/2"TEKS 3 970 (16 ga.) .036"-20 ga 3/16" 25 125 _ 1/4" 8027957 DST 200 1/4-14 x 2"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 3/8" 8038957 DSTR 1* 1/4-20 x 1"TEKS 3 1510 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 0 3/8" 8037957 DSTR 1-1/2* 12-24 x 1-112"TEKS 5 1510 (3/16") 1500 1475 .060"-16 ga. 1/2" 25 125 �} 3/8" 8039957 DSTR 516* 5/16-18 x 1-1/4"TEKS 3 2200 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 3/8" 8040957 DST 10 1/4-14 x 1"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 i 0 970 (16 ga.) 3/8" 8041957 DST 15 1/4-14 x 1-1/2"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8044957 DST 30 1/4-14 x 3"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) #14 Black 3/8" 8045957 DST 516 5/16-18 x 1-114"TEKS 3 1500 (3/16") 1500 1475 .125"-1/8" 3/16" 25 125 Nut Driver Y 0 3/8" 8046957 TEK 50 12-24 x 1-112"TEKS 5 3125 (3/16") 1500 1475 .250"-l/4" 1/2" 25 125 Part#8113910 446 (20 ga.) .::--•� 1/2" 8031925 DST 2.0 1/4-14 x 2"TEKS 3 g70 (16 ga.) .188"-3/16" 1/4" 25 125 .. 1/2" 8036925 TEK 5.0 12-24 x 1-1/2"TEKS 5 3125 (3/16") .188"-3/16" 1/2" 25 125 *Includes retaining nut #14 SW Red Nut Driver Part#8114910 s � oHS 00"I ASSEMBLED U.S.A. SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. ProductSIDEWINDERI FOR STEEL -Horizontal Application Application •Made with Teks°self-drilling fasteners-no pre-drilling required. NO •Installs into steel range from 20 gauge—1/2"thicknesses. }�� •A standard screwgun with a depth sensitive nosepiece should be used to install Teks.For optimal fastener performance,the screwgun should be a -- minimum of 6 amps and have an RPM range of 0-2500. Y0 •Saves time from traditional methods. J •Reduces installation costs. W •Quick to install using the Sammys Nut Driver with an View our W 18V cordless drill/driver. installation videos! •Asembled in the U.S.A. 0 YothbeApprovals Rod Part Model Screw Ultimate UL Test FM Test Min Max Box Case y Size Number D- Qty Qty HORIZONTAL MOUNT 3/8" 8050957 SWD 10 1/4-14 x 1"TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 v 3/8" 8052957 SWD 20 1/4-14 x 2"TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 3/8" 8055957 SWDR 1* 1/4-20 x 1"TEKS 3 1900 (20 ga.) 1500 1475 .036"-20 ga 3116" 25 125 3/8" 8054957 SWDR 1-1/2* 12-24 x 1-1/2"TEKS 5 2375 (3/16") 1500 1475 .188"-3/16" 1/2" 25 125 3/8" 8056957 SWDR 516* 5/16-18 x 1-1/4"TEKS 3 2480 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 *Includes retaining nut #14 SW Red Nut Driver Part#8114910 SAMMYS SWIVEL .Tm • - STEEL Application Application Product Features •Eliminates distortion of threaded rod in sloped roof applications. r •Accommodates 3-1/2 x 12 pitch. • •Installs into angled z-purlin;allows threaded rod to hang plumb. •Allows 17°deflection from vertical. •Asembled in the U.S.A. 1 View our installation videos! CYoubbe Approvals Rod Part Model Screw Ultimate UL Test I'M Test Min Max Box Case Size Number •. Qty Qty SWIVEL MOUNT M #14Black " 81379 11TEK S 3 X 1" ( ) Nut 3/8 57 SH-DSTR 1* Driver TEK 3220 3/16" 1500 1475 .035" 3/16" 25 125 Nut Part#8113910 2368(1/2"steel Vertical) 3/8" 8268957 SH-TEK 50 12-24 x 1-5/8" 1306(45°off Vertical) 1500(Vertical) 4" 3/16" 1/2" 25 125 TEKS 5 2281(3/16"HISS) 850(45°off Vertical) 2-1/2" 1585(3/16"HISS 45°off Vertical) *Does not comply with ROHS requirements/Includes retaining nut #14 SH Orange • Nut Driver Part#8273910 SA MMY X-PRESS® Installs into Metal Deck, Purlin, or Tubular Steel SAMMYX-PRESSOApplication ProductApplication •The Sammy X-Press expands to provide •Less jobsite material needed. direct vertical attachment in: (XP) - light gauge steel deck or purlin •No retaining nut required. � (22 ga.-1/8"). •Provides design flexibility. •Installs in seconds with Sammy X-Press It®Tool, saving time&installation costs. •Assembledin the U.S.A. •Use in applications where access to the back of View our the installed fastener is prohibited.is.metal roof installation videos! deck,tubular steel,or vapor barrier fabric. Woubbe DescriptionApprovals Rod Part Model Size Number Pullout(lbs) Load(lbs) Thick Load(lbs) Thick Thick • QtY MOUNTVERTICAL Sammy 185(Luminaire) .027 NL 1/4" 8181922 XP 200 X-P ess 200 1146(22 ga) 250(Luminaire) .056" .125" 25 125 Metal Deck ■ 850(2%"Pipe) .027" 940 (2"Pipe) 029" X-Press 20 250 3/8" 8150922 XP 20 Sammy 1146(22 ga) 250(Luminaire)(Luminaire) .0.056"" 1475(4"Pipe) .104" .125" 25 125 Metal Deck 283(Conduit&Cable) .029" 1500(4"Pipe) .060" 3/8" 8153922 XP 35 X Pr ss 35 1783(16 ga) 250(Luminaire) .056" 4775((4"PI pe) .1104" .125" 25 125 Purlin 416(Conduit&Cable) .059" T Pre-Pour Structural Concrete@ 3000 psi Metal Deck 3/8" 8150922 XP 20 Sammy 1146(22 ga) 850(2%Pipe) 25 125 (Pre-Pour) X-Press 20 Post-Pour Range II LWC<_35 PCF(lbs/ft3) Metal Deck (Post-Pour) Pre-Pour Structural Concrete @ 3000 psi Post-Pour Range II LWC<_35 PCF(Ibs/ft') —J—�VVE Lr -�- Lr'� SAMMYX-PRESS SIDEWINDER'" - Horizontal Application Application Product •The Sammy X-Press Sidewinder expands to •Less jobsite material needed. provide horizontal attachment in: 16 ga-3/16"steel-purlin,tubular steel. •No retaining nut required. •Installs in seconds with Sammy X-Press It®Tool, •Provides design flexibility. saving time&installation costs. •Assembled in U.S.A.of •Use in applications where access to the back of Canadian Steel the installed fastener is prohibited;ie.metal roof View our deck,tubular steel,or vapor barrier fabric. installation videos! 0 Youbbe DescriptionApprovals Rod Part Model Size NumberShear(Ibs) Load(lbs) Thick Load(Ibs) Thick Qty Qty HORIZONTAL MOUNT 1250(3%'Pipe) 3/8" 8293957 SWXP 35 Sidewinder 1798(16 ga) 80 (Luminaire) .059" .125" 25 125 Metal rlin in X-Press 35 416(Conduit&Cable) Pu � S ASSEMBLER U.S A. TM SAMMYX-PRESSA . . ProductApplication •The Sammy X-Press Swivel allows you •Less jobsite material needed. to hang plumb in extreme roof pitches: 89*in z-purlin •No retaining nut required. 45'in metal deck for 12/12 pitch � •Provides design flexibility. EREM •Installs in seconds with Sammy X-Press It®Tool, f)10' n 1 G saving time&installation costs. •Assembled in the U.S.A. V�p1�NT •Use in applications where access to the back of View our the installed fastener is prohibited.ie.metal roof installation videos! deck,tubular steel,or vapor barrier fabric. MOW— O — DescriptionApprovals Rod Part Model Size Number Pullout(Ibs) Load(Ibs) Thick Load(Ibs) Thick Thick Qty Qty MOUNTSWIVEL 750(2"Pipe) Swivel 1061(22 ga Vert) 170 Vertical(Luminaire) Metal Deck/ 3/8" 8294922 SXP 20 80 @ 45°(Luminaire) .029" 635(2"Pipe) .029" .125" 25 125 X-Press 20 829(45°Off Vert) 283 Vertical(Conduit&Cable) Pudin 11J 233 @ 45°(Conduit&Cable) 'W 1250(3-1/2"Pipe) 250 Vertical(Luminaire) ? 3/8" 8295922 SXP 35 Swivel 1675(16 ga Vert) 80 @ 90°(Luminaire) '059° '029" .125" 25 125(Luminaire) Metal Deck/ X-Press 35 1558(89°Off Vert) 500 Vertical(Conduit&Cable) 635(2"Pipe) Purlin 333 @ 89°(Conduit&Cable) 1/2" 8272957 SXP 2.0 Swivel 1061(22 ga Vert) .027" .125" 25 125 Metal Deck X-Press 2.0 829(45°Off Vert) Pudin 1/2" 8271957 SXP 3.5 Swivel 1675(16 ga Vert) Metal Deck/ X-Press 3.5 1558(89°Off Vert) .060" .125" 25 125 Pudin • SAMMYX- - - © • • • Application Product ` •The Sammy X-Press expands to provide direct vertical attachment in: metal deck(22-16 gauge) y4 J t z-purlin(18-16 gauge) •Assembled in the U.S.A. View our installation videos! 0 Youbbe DescriptionPart Number Model 8194910 UXPIT* Universal X-Press It Tool 1 8152910 XPDB 25/64"Drill Bit 1 'Tool Includes:Sleeve,Bit Receiver,Hex Wrench,and 25/64"Drill Bit. 1 1 • To find-distributor near y• 800-848-5611 SAMMYS° FOR CONCRETE SAMMYS@ FOR CONCRETE — Vertical Application Application Product Features •Easy two step process(Drill hole& *•4��'4 ,d o d v; �•4,'Q drive Sammys concrete anchor). ?" 'a r 4?" a •1W pre-drilled pilot hole required. . 7 ` .D `ad•`aJ�A�• :d `pd• •� •Concrete Installation Tool available for CC a one tool installation process. •Assembled in the U.S.A. -j .f••'ft••r ••r•' � j•• fir View our ... installation videos! 0YOUTUbe Size Number Descriptions Pullout(lbs)* Load(lbs)Approvals Rod Part Model Screw Ultimate I'M Test Box Case VERTICAL MOUNT #14 Black 1/4" 8058957 CST 200 5/16 x 1-3/4" 2400 25 125 Nut Driver FM 3/8" 8059957 CST 20 5/16 x 1-3/4" 2400 1475 25 125 Part#8113910 — #14SW Red 1/2" 8060925 CST 2 5/16 x 1-3/4" 2400 25 125 Nut Driver FM 36-EFM 3/8" 8306957 CCST 516 5116-14 x 2-1/2" 857** 25 125 Part#8114910 For complete performance data see ICC Report ESR-3699 Tested in 3000 PSI concrete **Pullout strength for Cracked Concrete and Seismic Zones A-F ProductSIDEWINDEW FOR CONCRETE - Horizontal Application Application �' •Easy two step process(Drill hole&drive •4• U°• Sammys concrete anchor). � I I • C p '�' o'P Z •'/<"pre-drilled pilot hole required. •Concrete Installation Tool available for a one tool D., -p. • C installation process. d ri ol77`4; , a o � •Assembleded in the U.S.A. View our installation videos! OYNTUM Approvals Rod Part Model Screw Ultimate FM Test Box Case Size Number 1• Qty Qty HORIZONTAL MOUNT 0 3/8" 8061957 SWC 20 5/16 x 1-3/4" 2450 1475 25 125 O 369gEFM 3/8" 8307957 SW-CCST 516 5/16-14 x 2-1/2" 857** 25 125 #14SW Red Tested in 3000 PSI concrete **Pullout strength for cracked concrete and Seismic Zones A-F Nut Driver Part#8114910 SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.ASSEMBLED U.S.A. �S free.Installation n t onis then complete.rWarranty requires thecuse ltof the appropriate nut driver for installations.continue drilling until nut driver spins OZZHH'yo SAMMYS SWIVEL HEAD Tm FOR CONCRETE Swivel Application Application Product Features •Installs vertically and swivels up to 89°in wood& concrete structures. •:moo s..�:=.P' Eliminates distortion of threaded rod. •1/4"pre-drilled pilot hole required. •Concrete installation tool available for a one piece installation process. •Assembled in the U.S.A. Approvals Rod Part Model Screw Ultimate Box Case Size Number .• Qty Qty SWIVEL MOUNT 2537 in 3000 psi concrete 3/8" 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1459 @ 45°off vertical in 3000 psi concrete 25 125 2852 in 6000 psi concrete 1636 @ 45°off vertical in 6000 psi concrete FM 3/8" 8308957 SH-CCST 516 5/16-14 x 2-1/2" 857** 25 125 Note:UL Listed for wood-see page 5 #14 SH Orange Nut Driver Part#8273910 *Tested in 3000 PSI concrete **Pullout strength for cracked concrete and Seismic Zones A-F Uj CONCRETE I WOOD INSTALLATIONLLI Ct V Application Z 'CRotary Hammer Drill into concrete Hammer Drill into concrete (b) b (9) (d) (h) (gam (e) (h) -sepiao, (C) (c) (a) Part Number Description Each Qty • 8122910 Concrete Installation Kit(a) 1 Kit includes the following items: 8113910 #14 Black Nut Driver(b) 1 8114910 #14 SW Red Nut Driver(c) 1 8116910c #250 Bit(1/4")(d) 1 8117910 SIDS Bit(1/4")(e) 1 8118910 7/32 Wood Bit(f) 1 8120910 HEX 250 Bit Receiver(1/4")(g) 1 8098910 SL 250 Sleeve(h) 1 To find a distributor near you,call 800-848-5611 ACCESSORIES SAMMYS TOGGLE TM Application Installation Steps 1.Pre-drill a 5/8"hole with a regular drill or hole saw. 4N, 2.Insert SST screw into#14 black nut driver.With wing nut and washer on bolt,insert wing nut through surface,and begin J installation. 3.When bolt is secure and nut driver spins free,stop drill motor and remove. Pre-Cast Hollow Core 4.SST screw is now ready to receive 114",3/8",or Metric all Concrete thread rod or bolt stock. o. r D• e ty 'Size Part Number Model • 450 (Lath&Plaster)' 3/8" 8064925 SST 30 1/4 x 3" 404 (2 Layers 5/8 Rock) 25 125 #14 Black Nut Driver Part#8113910 PIPE Application ,r •Complies with NFPA 13 Code Changes. •Flashing for dry pendant sprinklers subject to 4-f�RTITE 51 AY �p TO extreme temperature changes. CODE s •One piece construction is easy to install. --- with a qui<har, •Pipe diameter markings ensure accurate fit. U ARM more efficient war HOLE to fl4sh your •EPDM temperature range of-65OF to+250°F. refri9crationifreaicy units. tresrtUlTEo FREEZER STRUCTURE t—Nn fif>fU�118 Part Number Description Pipe Outside Diameter Dektite Base Diameter Dektite Height Box Qty 4003910 1 1/4"-2" 4-3/4" 3" 10 4004910 2 1-3/4"-3-1/4" 6-1/4" 4" 10 . 1. - 1 11. 611 11. oil SAMMYX-PRESS POLE TOOL • Application Product Features Speed your labor by 25% Work from the ground up It �w No scaffolding,ladders,or lifts v Perfect for working in tight spaces,through ceiling grid, --— and high vaulted ceilings For use installing Works with any Sammy X-Press product t Sammy X-Press anchors from the ground up! View our installation videos! p YouTube r Part Number Model Description Box Qty 1 XPKIT* XPKIT Sammy X-Press Pole Tool Kit 1 3/4"electdcal conduit needed for pole tool assembly • ji• SAMMYS �. POLE TOOL TIM Installation , Product Speed your labor by 25% 1 2 3 Insert •Work from the ground up adjust! here No scaffolding,ladders,or lifts Perfect for working in tight spaces,through ceiling grid, Adjust the Pole Tool to length. Load rod and Sammys into The socket will spin free and high vaulted ceilings The adjusting pin must be 18" Pole Tool. when the screw is completely below the base or the pin may installed.Pull down to remove •Works with any Vertical SAMMYS:Wood,Steel,or interfere with the rod. the Pole Tool. Concrete • Part Number Description Box Qty Pole 6'-18' 1 W W O 0 W V V Q • APPROVALS Part Numberr . ..• Mount UL Max ULTest UIL Min Wood FM Max FM Test FM Min Wood _ 8007957 GST 10 3/8" Vertical CPVC 1-1/2" 300 1-1/2" 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2" 300 1-1/2" 8008957 GST20 3/8" Vertical 2-1/2" 850 1-1/2" 4" 1475 1-1/2' 8068925 GST20-SS 3/8" Vertical 2-1/2" 850 1-1/2" 8010957 GST30 3/8" Vertical 4" 1500 1-1/2" 4" 1475 1-112' 8009925 GST25-380 3/8" Vertical 4" 1500 1-1/2" 8022925 SWG25-380 3/8" Horizontal 3-1/2"-4"* 1500 1-1/2" 8021957 SWG 20 3/8" Horizontal 2-1/2"-3"** 1050 1-1/2" 8073925 SWG 20-SS 3/8" Horizontal 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45°Angle off Vertical 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45"Angle off Vertical 4" 1500 1-1/2" 8139957 SH-GST 20 3/8" 17°Angle off Vertical 3" 1050 1-1/2" 4" 1475 1-1/2" SAMMYS FOR STEEL-PIPE HANGER Min Steel Thick Max Steel Thick 8038957 DSTR 1 3/8" Vertical 4" 1500 .035" 4" 1475 .105" 8037957 DSTR 1-1/2 3/8" Vertical 4" 1500 .035" 4" 1475 .105" 8039957 DSTR 516 3/8" Vertical 4" 1500 .037" 4" 1475 .105" 8045957 DST 516 3/8" Vertical 4" 1500 .188" 4" 1475 .188" 8046957 TEK 50 3/8" Vertical 4" 1500 .250" 4" 1475 .188" 8055957 SWDR 1 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8056957 SWDR 516 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8054957 SWDR 1-1/2 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8137957 SH-DSTR 1 318" 17'Angle off Vertical 4" 1500 .035" 4" 1475 .105" 8268957 SH-TEK50 3/8" Vertical 2-1/2" 850 70*Angle off Vertical 4" 1500 8150922 XP 20 3/8" Vertical 2-1/2" 850 .027" 2" 940 .029" 4" 1475 .105" 8153922 XP 35 3/8" Vertical 4" 1500 .060" 2" 940 .029" 4" 1475 .125" 8294922 SXP 20 3/8" Vertical or up to 45° 2" 750 .027" 2" 635 .029" 8295922 SXP 35 3/8" Vertical or up to 89' 3-1/2" 1250 .060" 2" 635 .029" 8293957 SWXP 35 3/8" Horizontal 3-1/2" 1250 .060" SAMMYS FOR CONCRETE-PIPE HANGER 8059957 CST 20 3/8" Vertical 4" 1475 3000 8061957 SWC 20 3/8" Horizontal 4" 1475 3000 8150922 XP 20 3/8" Vertical 2-1/2" 850 Pre-Pour Structural @ 3000psi 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Range II LWC<_35 PCF(lbs/fC) Part Model .. Mount UL Load UL Min Steel SAMMYS Number Size Direction Rating(Ibs) Thickness 8150922 XP 20 3/8" Vertical 185 .027" 250 .035" 8153922 XP 35 318" Vertical 185 .027" 250 .035" 8181922 XP 200 1/4" Vertical 185 .027" 250 .035" 8294922 SXP 20 3/8' Vertical 170 .027" 45' 80 .027" 8295922 SXP 35 3/8' Vertical 250 .060" 90* 80 .060" 8293957 SWXP 35 3/8" Horizontal 80 .060" Part Model Rod Mount UL Load UL Min.Steel Listed Application Number Size Direction Rating(Ibs) Thickness SAMMYS FOR CONDUIT, 8150922 XP 20 3/8" Vertical 283 .027" Max 4 trade size EMT,RMC,and IMC&5 trade size rigid PVC conduit 8153922 XP 35 3/8" Vertical 500 .060" Max 4 trade size EMT&6 trade sze RMC,IMC,and rigid PVC conduit 8294922 SXP 20 3/8" Vertical 283 .027" Max 4 trade size EMT,RMC,and IMC&5 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMT&6 trade sze RMC,IMC,and rigid PVC conduit 8293957 SWXP 35 3/8" Horizontal 500 .060" Max 4 trade size EMT&6 trade sze RMC,IMC,and rigid PVC conduit 8149957 CZ2000 1/4"or 3/8" Onto Vertical Rod UL Listed 4S16-Cable Hanger,Cat.No.C-Z2000 Plenum Rated, Complies w/NEC Standards GaugesSheet Steel Gauge No. 22 ga. 20 ga. 18 ga. 16 ga. 14 ga. 12 ga. 1/8" 3/16" 1/4" Nominal Decimal Equivalent .030" .036" .048" .060" .075" .105" .125" .188" .250" *SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-112" UL compliance with NEC Standards. *SWG 25-380 Maximum pipe size in wood timber orjoist allowed by UL is 4" UL and FM tests were performed in compliance with NFPA 13 Standards. **SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-112" Fastening requirement:5 times weight of water-filled schedule 40 pipe plus 250 pounds. **SWG 20 Maximum pipe size in wood timber or'oisl allowed to UL is 3" SPECIAL NOTES • Engineering Note • In 1996,the anchors listed by UL were tested in plate steel that measured.188"and.118".Subsequent testing was done for z-purlin applications in May 1997 using(.037")or 20 gauge steel.Most recently in 2008,testing with the new Sammy X-Press®was completed using(.030")or 22 gauge steel metal deck. Sammys®Nut Drivers Special nut drivers were designed to be used with Sammys.When the appropriate nut drivers are used for installation,the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap,reduces over-torque,and prevents screw failure. Steel Screws Due to variations in hardness of certain metals,it should be noted that our self-drilling screws for steel will experience different drill speeds.500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offerring. Vibratory Environments For attaching or anchoring in high vibratory environments,special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist.UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss.Sammy GST 20 can be installed into the center of the lower cord of a composite joist.Penetration of the upright center web is permitted by some joist manufacturers.Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers.If so,pre-drill pilot hole 1/8"smaller than root diameter of fastener. Consult the table below: Model Root Diameter Hole Size GST 20 .182" 1/8" GST 25-380 .280" 7132" SWG 20 .182" 1/8" SWG 25-380 .280" 7/32" To increase efficiency of the installation process,sleeve tools,bit receivers,and wood bits are available for pre-drilling. NFPA/NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards.Check with your local(AHJ)Authority Having Jurisdiction to confirm application and usage. UL Listings/FM Approvals UL and FM reports are available at www.itwbuildex.com �uLD 5 O • 111B RAKER ALSO LISTED AS CONDUIT AN O CABLE HARD WARE ALSO USMB AS ANCHOR FOR LUMINAIRE B., Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats:.dwg,.dxf,and.igs. Assembled in the U.S.A. Products Contact Information As—bledUSA Technical Assistance:(800)848-5611 Option#6(x 3259) Customer Service:(800)848-5611 Option#1 • J Q Q. Q. Q 15 To find a distributor near you,call 800-848-5611 115 Standard Duty - i The 115 Standard Duty Loop Hanger is ideal for suspending stationary, non-insulated pipe lines,including CPVC pipes, in fire sprinkler systems.A knurled insert nut helps simplify vertical adjustments and flared edges on the base(1/2"to 4"sizes) help protect pipes from coming into contact with any sharp edges of the hanger. • Flared edges help prevent any sharp surfaces from coming into contact with the pipe(1/2"to 4" sizes) • Retained insert nut helps ensure the loop hanger and insert nut stay together • Recommended for the suspension of stationary non-insulated pipe lines • Manufactured to use the minimum rod size permitted by NFPA°for fire sprinkler piping • Conforms with Federal Specification WW-H-171 (Type 10), Manufacturers Standardization Society(MSS)SP-58(Type 10) �- -RS C 8 A OD �F Material:Steel FM Finish: Pregalvanized C UL US wv►•oveo Outer Diameter Rod Size Static Load Part Number Pipe Size OD RS A f3 C F Certifications 1150050EG 1/2" 0.840" 3/8" 213/16" 11/8" 1" 3001b cULus 1150075EG 3/4" 1.050" 3/8" 3" 1 3/16" 15/16" 300 1b cULus,FM 1150100EG 1" 1.315" 3/8" 3 1/4" 1 3/8" 15/16'* 3001b cULus,FM 1150125EG 1 1/4" 1.660" 3/8" 3 9/16" 1 1/2" 15/16" 300 1b cULus,FM 1150150EG 1 1/2" 1.900" 3/8" 3 13/16" 1 5/8" 15/16" 300 lb cULus,FM 1150200EG 2" 2.375" 3/8" 4 1/4" 1 7/8" 15/16" 300 lb cULus,FM 1150250EG 2 1/2" 2.875" 3/8" 5 15/16" 3 7/16" 2" 5251b cULus,FM 115030DEG 3" 3.500" 3/8" 6 9/16" 3 1/2" 1 15/16" 525 lb cULus,FM 1150350EG 3 1/2" 4.000" 3/8" 7 1/16" 3 3/4" 1 15/16" 585 lb cULus,FM 1150400EG 4" 4.500" 3/8" 7 9/16" 4" 1 15/16" 650 lb cULus,FM 1150500EG 5" 5.563" 1/2" 9 13/16" 4 3/4" 2 1/4" 1,000[b cULus,FM 1150600EG 6" 6.625" 1/2" 11 5/16" 6 5/16" 3 5/16" 1,000 lb cULus.FM 1150800EG 8" 8.625" 1/2" 12 7/8" 6 7/8" 2 7/8" 1,000 lb cULus,FM nJent CADDY FM is a registered certification mark of FM Approvals LLC,LTD.NFPA is a registered trademark of National Fire Protection Association,Inc.UL,UR,cUL,cUR,cULus and cURus are registered certification marks of UL LLC. WARNING nVent products shall be installed and used only as indicated in nVent's product instruction sheets and training materials,Instruction sheets are available at www.erico.com and from your nVent customer service representative.Improper installation,misuse,misapplication or other failure to completely follow nVent'a instructions and warnings may cause product malfunction,property damage,serious bodily injury and death and/or void your warranty. ®2019 nVent All rights reserved nVent,nVent CADDY,nVent ERICO,nVent ERIFLEX and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners.nVent reserves the right to change specifications without prior notice. v, mkiri CADDY / • © Seismic Braces `11111�:p Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig.AF730 Material Specifications Size Range Service Pipe Size:1"-12",DN25-DN100 e Material Carbon Steel Clamp and Hardware.Ductile Iron Brace Member Attachment Fitting. Finish ❑ Plain ❑ Clamp:Hot Dipped Galvanized per i� ASTM A153 c �L us Fnn ❑ Brace Member Attachment Fitting: LISTED APPROVED Electro-Galvanized per ASTM B633 A Service A seismic longitudinal and Lateral brace clamp designed to connect a piping system to a brace BO member.The AF730 rigidly braces piping systems :+ O subjected to horizontal and vertical seismic loads. Y Approvals cULus Listed(ANSI/UL 203a)and FM Approved (FM 1950-13).FM Tested(ANSI/FM 1950-16). FIG.AF730 Dimensions and Weight Complies with NFPA 13,ASCE 7,IBC,&MSS SP-127 bracing requirements. Size A B Y Weight Features In./mm In./mm In./mm Ibs/kgs • Torque off set screw and nuts provide a visual 1"(DN25) 7.6 193 2.49 1.13 indication that the desired installation torque 11/2"(DN32) 8.0 203 2.55 1.13 values have been achieved. 11/2" DN40 8.2 208 2.64 1.20 Ordering ( ) Specify figure number,service pipe size,finish, 2"(DN50) 8.7 221 2.78 1.26 and description. 21/2" 9.2 234 2.92 1.32 DiscLaimer: ASC Engineered Solutions does not provide any warranties 3"(DN80) 9.8 249 3.13 1.42 and specifically disclaims any liability whatsoever with 1.50 38.1 1.91 48.5 respect to ASC bracing products and components that 4"(DN 100) 10.8 274 3.38 1.53 are used in combination with products,parts or systems not manufactured or sold by ASC.In no event shall ASC 5" 12.1 307 3.81 1.73 be liable for any incidental,direct,consequential,special or indirect damages or lost profits where non-ASC bracing 6" 13.2 335 4.12 1.87 components have been,or are used. 8 15.2 386 6.40 2.90 Sells Brace'Seismic Fire Protection Design Tool may be accessed at www.seisbrace.com 10" 18.1 460 7.60 3.45 12" 20.1 511 8.60 3.90 Notes: ASC Engineered SolutionsT"'brand bracing components are designed to be compatible ONLYwith other AFCON® ASC Engineered Solutions brand bracing components,resulting in a Listed seismic bracing assembly. 10 Updated UL listing information may be viewed at www.uL.com and updated FM approval information may be viewed at www.approvaLguide.com. An ASC Engineered Solution PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SS-07.20 page 1 SS-SUB-AF730-vO4 20221228 AFCONO Seismic Braces MC Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig.AF730 FIG.AF730 cULus Listing per ANSI/UL 203a(ASD) Horizontal Load Rating at Brace Angle Service Standard Specialty Longitudinal Load Rating Lateral Load Rating Pipe Service Service V.,O `11111�:p Size Pipe Pipe 30°-44° 45`-59` 60°-90° Listed 30`-44` 45°-59° 60°-90° Listed VAN VAN VAN IVAN IVAN VAN VAN VAN Sch.A Mega-Thread 1 Sch.40 MLT/GL 340 480 588 680 340 480 588 680 (DN25) Metric Pipe Eddy Thread 1.51 2.14 2.62 3.02 1.51 2.14 2.62 3.02 EZ-Thread Mega-Flow O Sch.10 MLT/GL 11/4 Sch.40 Mega-Thread (DN32) Metric Pipe EEddd Flow Longitudinal Application ThreaEZ-Thread Mega-Flow MLT/GL 11/2 Sch.10 Mega-Thread Sch.40 Eddy Flow 375 530 649 750 375 530 649 750 (DN40) Metric Pipe Eddy Thread 1.67 2.36 2.89 3.34 1.67 2.36 2.89 3.34 Fire-Flo EZ-Thread Mega-Flow MLT/GL 2" Sch.10 Mega-Thread (DN50) Sch.40 Eddy Flow Metric Pipe Eddy Thread Fire-Flo 0 EZ-Thread Mega-Flow 21/2 Sch.10 Eddy Flow Sch.40 Fire-Flo Lateral Application 545 770 943 1090 545 770 943 1090 Sch.10 Mega-Flow 2.42 3.43 4.19 4.85 2.42 3.43 4.19 4.85 3 Sch.40 Eddy Flow (DN80) Metric Pipe Fire-Flo 4„ Sch.10 Mega-Flow (DN100) Sch.40 Eddy Flow Metric Pipe Fire-Flo 51, Sch.10 _ Sch.40 Sch.10 942 1333 1632 1885 942 1333 1632 1885 6 Sch.40 Mega-Flow 4.19 5.93 7.26 8.38 4.19 5.93 7.26 8.38 Sch.10 8" 0.188"Wall - Riser Application Sch.40 10" 0.188"Wall _ Sch.40 Brace Angles are determined from Vertical. Sch.10&0.188"Wall Load Ratings may be used for any thicker wall pipe of the same diameter. ®© Listed load ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3. See table on page 4 for UL listed specialty pipes&UL Listed metric service pipes. asc-es.com See table on page 4 for UL listed brace members. Load ratings include a minimum safety factor of 2.2 in accordance with NFPA13-2019 Section A.18.5.2.3. BUILdIng connections that Last' All load ratings may be used for NFPA 13-2016 designs. SS-07.20 page 2 SS-SUB-AF730-v0420221228 AFCONO Seismic Braces MC Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig.AF730 FIG.AF730 FM Approved(Listing)per FM 1950-13(ASD) Horizontal Load Rating at Brace Angle Service Standard Specialty Longitudinal Load Rating Lateral Load Rating Pipe Service Service VAO %IIZ:P Size Pipe Pipe 30°-44° 45°-59° 60°-74° 75°-90° 30°-44° 45°-59° 60°-74° 75°-90° Ibf/kN Ibf/kN Ibf/kN Ibf/kN Ibf/kN Ibf/kN Ibf/kN bf/kN Sch.10 Mega-Thread V Sch.40 MLT/GL 550 640 670 740 1740 2460 3010 3360 (DN25) Metric Pipe Eddy Thread 2.24 2.84 2.98 3.29 7.74 10.94 13.39 14.95 EZ-Thread Mega-Flow 0 Sch.10 MLT/GL 1Y4" Sch.40 Mega-Thread 740 680 820 1620 1430 2020 2480 2770 (DN32) Metric Pipe Eddy Flow 3.29 3.02 3.65 7.21 6.36 8.99 11.03 12.32 Eddy Thread Lon itudinatA EZ-Thread g ppllcatlon Mega-Flow Sch.10 MLT/GL 1v2" Sch.40 Mega Thread Y 800 650 790 1800 1790 2530 3100 3460 ( ) DN40 Metric Pipe Eddy Flow Eddy Thread 3.56 2.89 3.51 8.01 7.96 11.25 13.79 15.39 Fire-Flo EZ-Thread Mega-Flow Sch.10 MLT/GL 2" Sch.40 Mega Thread Y 830 990 1190 1620 1820 2580 3160 3530 ( ) DN50 Metric Pipe Eddy Flow Eddy Thread 3.69 4.4 5.29 7.21 8.1 11.48 14.06 15.7 Fire-Flo EZ-Thread 2h' Sch.10 Edda Flow 800 700 850 1930 1610 2280 2790 3120 Sch.40 Fire-Flo 3.65 3.11 3.78 8.59 7.16 10.14 12.41 13.88 Sch.10 Mega-Flow Lateral Application 3" Sch.40 EddyFlow 960 1330 1540 1700 1550 2200 2690 3010 (DN80) Metric Pipe Fire-Flo 4.27 5.92 6.85 7.56 6.89 9.79 11.97 13.39 4" Sch.10 Mega-Flow 760 1040 1270 1400 1260 1790 2190 2440 (DN100) Sch.40 Eddy Flow Metric Pipe Fire-Flo 3.38 4.63 5.65 6.23 5.6 7.96 9.74 10.85 51, Sch.10 _ 890 1230 1410 1550 1260 1790 2190 2440 Sch.40 3.96 5.47 6.27 6.89 5.6 7.96 9.74 10.85 6„ Sch.10 Mega-Flow 700 940 1140 1310 950 1340 1640 1830 Sch.40 3.11 4.18 5.07 5.83 4.23 5.96 7.3 8.14 8„ 0.188"Wall _ 990 1130 1360 1520 1540 2170 2660 2970 Sch.40 4.4 5.03 6.05 6.76 6.85 9.65 11.82 13.21 10" 0.188"Wall _ 1020 850 1000 1100 1700 2410 2950 3290 Riser Application Sch.40 4.54 3.78 4.45 4.89 7.56 10.72 13.12 14.63 12" 0.188"Wall _ 970 1010 1220 1430 1690 2390 2930 3270 Sch.40 4.31 4.49 5.43 6.36 7.52 10.63 13.03 14.55 Brace Angles are determined from Vertical. Sch.10&0.188"Wall Load Ratings may be used for any thicker wall pipe of the same diameter. [moo Load ratings include a minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.5.2.3.To convert the load ratings above to a safety factor of 2.2 per NFPA 13-2019 Section A.18.5.2.3,multiply load ratings asc-es.com by a factor of 0.68. To convert to LRFD Load Ratings,ASD Load Ratings may be multiplied by a factor of1.5. BUILdIng connections that Last" See table on page 4 for FM approved metric service pipes. See table on page 4 for FM approved brace members. SS-07.20 page 3 SS-SUB-AF730-v0420221228 AFCONO Seismic Braces rlrs:) / Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig.AF730 Method 1 - Connection to Brace Member First I Slide the brace member over the lowerjaw until it contacts the back wall of the brace member attachment fitting. 2 Hand tighten the set screw until it contacts the brace member.Continue to torque the set screw until the head breaks off. 3 Rotate the brace assembly to the service pipe.Unbolt the back nut&bolt and rotate the clamp halves over the service pipe.Re-assemble the nut and bolt. 4 Hand tighten the nuts on both sides of the clamp.Evenly and alternately torque the nut until the head breaks off.It is best practice to tighten the nut at thejaw side first. 5 Ensure the brace angle is within the range specified. Method 2 - Connection to Service Pipe First 1 Unbolt the back nut&bolt and rotate the clamp halves over the service pipe. Re-assemble the nut and bolt. 2 Hand tighten the nuts on both sides of the clamp.Evenly and alternately torque the nut until the head breaks off.It is best practice to tighten the nut at thejaw side first. 3 Slide the brace member over the lowerjaw until it contacts the back wall of the brace member attachment fitting. 4 Hand tighten the set screw until it contacts the brace member.Continue to torque the set screw until the head breaks off. FIG.AF730 cULus Listed&FM Approved Brace Members Brace Member Sizes Standards(or Equivalent) UL Listed FM Approved Sch.40 1",1 Y,",1 v2",2" ASTM A53,Al 06,Al 35,or ✓ ✓ NIPS Pipe A795 Sch.40 Metric Pipe KS D 3562 ✓ ✓ DN25,DN32, EN10255H ✓ Metric Pipe DN40,DN50 GB/T3091 ✓ AS G3454 ✓ FIG.AF730 cULus Listed&FM Approved Metric Service Pipes Brace Member Service Pipe Sizes UL Listed FM Approved KS D 3507 ✓ ✓ KS D 3537 KS D 3562 ✓ ✓ Sch.40 G B/T 3091 ✓ GB/T 3092 DN25,DN32,DN40, JIS G3452 DN50,DN 80,DN100 ✓ EN10255M asc-es.com EN 10255H Building connections that last" ss-07.20 page 4 SS-SUB-AF730-v04 20221228 AFCONO Seismic Braces kkp Engineered Solutions Model Q Lateral Sway Brace Fig.AF001 Material Specifications Size Range: Service Pipe Size:1"-4",DN25-DN100 Brace Member:T'-11/a",DN25-DN32 Material Carbon Steel Finish ❑ Plain ❑ ELectro-Galvanized Service A seismic lateral brace designed to connect a brace member to the service pipe.The AF001 rigidly braces steel piping systems subjected to y - horizontal and vertical seismic loads. Approvals :;00 cULus Listed(ANSI/UL 203a),FM Approved(FM 40. 1950-13),&OSHPD(OPM-0351-13).Complies with NFPA 13,ASCE 7,IBC,&MSS SP-127 bracing 1'to 4"Service Pipe requirements. Features The indicator clip provides a visual indication that proper installation has been achieved.. 047)pd c&s FM Ordering OPM-0351-13 LISTED APPROVED Specify figure number,service pipe size,brace size,finish,and description. FIG.AF001:Weight and Installation Torque Service Pipe Size Brace Member Size Installation Torque 1"(DN25) 1"(DN25) 1"(DN25) 0.82 lbs 0.87 lbs 1 Ya"(DN32) 0.86 lbs 0.90 lbs 14 ft-lbs I'Y'(DN40) 0.90 lbs 0.95 lbs 2"(DN50) 0.96 lbs 1.00 lbs 21/2" 1.02 lbs 1.06 lbs DN65 1.05 lbs 1.09 lbs 16 ft-lbs 3"(DN80) 1.09 lbs 1.13lbs AFCON® 4"(DN100) 1.23 lbs 1.26 lbs 17 ft-lbs 10 An ASC Engineered Solution PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SS-06.21 page 1 SS-SUB-AF001-v03 20220303 AFCONO Seismic Braces Model Q Lateral Sway Brace Engineered Solutions Fig.AF001 V.4 FIG.AF001 cULus Listing per ANSI/UL 203a(ASD) Service Pipe Size Service Pipe Horizontal Load Rating at Brace Angle 30°-44° 45°-59° 60°-90° Listed 1"(DN25) ,/Z (M12) 1 Yn"(DN32) 0 Sch.10 11h"(DN40) Sch.40 Metric Pipe 2"(DN50) 340lbf 480lbf 588lbf 680lbf Lateral Application (1.51 kN) (2.14 kN) (2.62 kN) (3.02 kN) 21/2„ Sch.10 Sch.40 DN65 Metric Pipe 3"(DN80) Sch.10 Sch.40 4"(DN100) Metric Pipe 1) Brace Angles are determined from Vertical. 0 2) Sch.10 Load Ratings may be used for any thicker wall pipe of the same diameter. r"Min. 3) Listed load ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3. 4) Load Ratings reflect 1"(DN25)—11/4"(DN32)brace members.See table below for Listed brace members. 5) Minimum safety factor of 2.2 in accordance with NFPA 13-2019 Section A.18.5.2.3. Lateral Application Fig.AF001 cULus Listing per ANSI/UL 203A(ASD)for NFPA 13-2016 editions or earlier UL's current Listings are predicated on installation in accordance with the latest edition of NFPA 73.The 2076 and earlier editions of NFPA 13 referenced a minimum safety factor of 1.5 for the load rating as compared to 2.2 for the O current edition.The load ratings noted in this table are consistent with the historical cULus Listings that were evaluated to the requirements of UL 203A,Outline of Investigation for Sway Brace Devices for Fire Sprinkler System Piping,based upon a minimum safety factor of 7.5 in accordance with the earlier editions of NFPA 73.The load ratings based upon the 2016 or earlier editions of NFPA 13 should only be used where approved by the Authority HavingJurisdiction(AHJ). Service Pipe Size Service Pipe Horizontal Load Rating at Brace Angle 30°-44° 45°-59° 60°-90° Listed I"(DN25) 1/n 0 (M12) 11/,"(DN32) Sch.10 O 11h"(DN40) Sch.40 Metric Pipe 2"(DN50) 500lbf 707 Ibf 865 Ibf 1000 Ibf (2.22 kN) (3.15 kN) (3.85 kN) (4.45 kN) 21r2" Sch.10 Riser Application Sch.40 DN65 Metric Pipe 3"(DN80) Sch.10 Sch.40 4"(DN100) Metric Pipe 1) Brace Angles are determined from Vertical. 2) Sch.10 Load Ratings may be used for any thicker waLL pipe of the same diameter. 3) Listed load ratings reduced for angle ranges in accordance with NFPA 13-2016 Table 9.3.5.2.3. 4) Load Ratings reflect 1"(DN25)—11/4"(DN32)brace members.See table below for Listed brace members. 5) Minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.5.2.3 ®©o asc-es.com Building connections that last" SS-03.22 page 2 SS-SUB-AF001-v03 20220303 / • © Seismic Braces Model Q Lateral Sway Brace Engineered Solutions Fig.AF001 FIG.AF001 FM Approved(Listing)per FM 1950-13(ASD) Service Pipe Size Service Pipe Horizontal Load Rating at Brace Angle V.4 14ZP 30°-44° 45°-59° 60°-74° 75°-90° 1"(DN25) 1'4"(DN32) (DN40) 0 LWZ 2501bf 3601bf 4401bf SOOIbf 2"(DN50) (1.11 kN) (1.60 kN) (1.96 kN) (2.22 kN) Lateral Application 216„ 3"(DN80) 4"(DN100) LW2 410lbf 590 Ibf 720 Ibf 800 Ibf (1.82 kN) (2.62 kN) (3.2 kN) (2.56 kN) 1"(DN25) 1 Ya'(DN32) Sch.10 0 Sch.40 2"Min. 11h"(DN40) Metric Pipe 1\ 2"(DN50) 5001bf 81011bf 1000lbf 1100lbf Lateral Application (2.22 kN) (3.6 kN) (4.45 kN) (4.89 kN) 21/2 Sch.10 Sch.40 DN65 Metric Pipe Sch.10 O 3"(DN80) Sch.40 Metric Pipe Sch.10 760IV 1070IV 1320lbf 1470lbf 4"(DN100) Sch.40 (3.38 kN) (4.76 kN) (5.87 kN) (6.54 kN) Metric Pipe 1) Brace Angles are determined from Vertical. 0 2) LW Refers to FM Approved Lightwall pipe,commonly referred to as Sch.7 and Flow Pipe.See FM Approval Guide for approved Lightwall pipe. 3) Sch.10 Load Ratings may be used for any thicker wall pipe of the same diameter. 4) See table below for FM listed specialty pipes&FM Listed metric service pipes. 5) Load Ratings reflect 1"(DN25)-11/4"(DN32) brace members.See table below for listed brace members. 6) Minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.5.2.3.To convert the load ratings O above to a safety factor of 2.2 per NFPA 13-2019 Section A.18.5.2.3,multiply load ratings by a factor of 0.68. 7) To convert to LRFD Load Ratings,ASD Load Ratings may be multiplied by a factor of 1.5. Riser Application ®©o asc-es.com Building connections that last" SS-11.21 page 3 SS-SUB-AF001-v0320220303 AFCONO Seismic Braces Model Q Lateral Sway Brace Engineered Solutions Fig.AF001 Place the AF001 over the service pipe to be braced. V.4 Z Insert the brace member through the open loop and the bracket.The end of the brace pipe shall extend at least tin(50.8mm)past the bracket. 3 Hand tighten the nuts equally until the bracket contacts the brace member.Continue to torque the nuts equally and alternately until indicator clip is flat and the installation torque ZO has been achieved. 4 Ensure the brace angle is within the specified range. Notes:The brace member may be installed above or below the service pipe. FIG.AF001 cULus Listed&FM Approved Brace Members Brace Member Sizes Standards(or Equivalent) UL Listed FM Approved Sch.40 1„ 11/4„ ASTM A53,Al06, ✓ ✓ NPS Pipe Al35,or A795 Sch.40 Metric Pipe KS D 3562 DN25 EN10255H Metric Pipe DN32 GB/T3091 JIS G3454 FIG.AF001 cULus Listed&FM Approved Metric Service Pipes Brace Member Service Pipe Sizes UL Listed FM Approved KS D 3507 KS D 3537 KS D 3562 Sch.40 DN25 GB/T 3091 DN32 GB/T 3092 DN40 ✓ DN50 JIS G3452 DIN 80 ✓ DN100 EN 10255M EN 10255H Notes: ASC Engineered SolutionsTm brand bracing components are designed to be compatible ONLYwith other ASC Engineered Solutions brand bracing components,resulting in a Listed seismic bracing assembly.Updated UL listing information may be viewed at www.uL.com and updated FM approval information may be viewed at www. approvalguide.com. Disclaimer: ASC Engineered Solutions does not provide any warranties and specifically disclaims any liability whatsoever with respect to ASC bracing products and components that are used in combination with products,parts or systems not manufactured or sold by ASC.In no event shall ASC be liable for any incidental,direct,consequential,special or indirect damages or lost profits where non-ASC bracing components have been,or are used. Sells Brace®Seismic Fire Protection Design Tool may be accessed at www.seisbrace.com ®©o asc-es.com Building connections that last" SS-05.21 page 4 SS-SUB-AF001-v03 20220303 FireLock EZ° Rigid Coupling C&f FM yds ilu4 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 009H The FireLock EZ Style 009H coupling is a rigid, installation-ready coupling for fire protection pipe joining.The coupling's unique design eliminates loose parts, insures consistent installation and provides substantial gains in productivity. IMPORTANT FireLock EZ Style 009H couplings are recommended for use ONLY on fire protection systems. PATENTED LISTINGS/APPROVALS * The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies.Contact Victaulic for performance on other pipe and the latest listings and approvals. Standard Pipe Nominal Size 11/a 175 365 365 365 365 32 1206 2517 2517 2517 2517 11h 175 365 365 365 365 40 1206 2517 2517 2517 2517 2 175 365 365 365 365 50 1206 2517 2517 2517 2517 21h N/A 365 365 365 365 65 2517 2517 2517 2517 76.1mm N/A N/A 365** 365 365 2517** 2517 2517 3 N/A 365 365 365 365 80 2517 2517 2517 2517 4 365 365 365 365 100 N/A 2517 2517 2517 2517 165.1mm N/A N/A 290** 232 300 1999** 1600 2068 6# N/A 290 365 232 365 150# 1999 2517 1600 2517 rt Listed/Approved for wet and dry pipe systems(>—40°F/-400C). Please refer to the Victaulic Installation Manual(1-009H_009_009V.pdf)for details concerning when supplemental lubrication is required. *` EN-10219(L)for 76.1mm size;EN-10255(M)for 165.1mm size # Regional availability only Speciality Pipe Pipe Size psi/ a Pipe Size psi/ Pipe Size /kPa BLT 1 Ya—2 300 300 EZT 1/a—2 300 300 MT 1'/a—2 300 300 2068 2068 2068 2068 2068 2068 DF 1 Ya—4 300 300 FF 1 Ya—4 300 300 MLT 1 Ya—2 N/A 300 2068 2068 2068 2068 2068 DT 1 Ya—2 300 300 FLF 1 Ya—4 N/A 300 ST 1'/a—2 N/A 300 2068 2068 2068 2068 EF 1 Ya—4 175 175 FLT 1 Ya—2 N/A 300 STF 1'/a—4 N/A 300 1206 1206 2068 2068 EL 1 Ya—2 300 300 FLTL 1 Ya—2 N/A 300 TF 2Ya—4 N/A 300 2068 2068 1 2068 1 1 2068 ET40 1'/a—2 300 300 GL 1 Ya—2 300 300 WLS 1'/a—2 300 300 2068 2068 2068 2068 2068 2068 EZF 3-4 300 300 MF 1'/a-4 300 300 WST 1'/a-2 N/A 175 2068 2068 2068 2068 1206 XL 1'/a—2 300 300 2068 2068 JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IC_tau I1C REV_F 10.61_1 IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 10.61 FireLook EZ° Rigid Coupling STYLE 009H STYLE 009H DIMENSIONS No.-Size Dimensions-Inches/mm L�a e m b I ed ss St R1.660365 condition) Joint Assembled M Inches X 1 Ya 790 0.10 1 2 -3/8 x 2 1 2.95 1 4.77 2.70 1 4.63 1.93 1.4 32 42.4 2517 1 3514 2.54 -M10 x 2 75 121 69 1 118 49 1 0.7 1'/2 1.900 365 1035 0.10 2 -3/8 x 2 3.19 4.97 2.94 4.79 1.93 1.5 40 48.3 2517 4604 2.54 -M10 x 2 81 126 75 122 49 0.7 STYLE 009H PRE-ASSEMBLED 2 2.375 365 1616 0.12 2 -3/8x2 3.79 5.53 3.45 5.42 1.93 1.9 (PUSH ON CONDITION) 50 60.3 2517 7193 3.05 -M10 x 2 96 140 88 138 49 0.9 2'/2 2.875 365 2370 0.12 2 -3/8 x 2'/2 4.29 6.09 3.92 5.85 1.93 2.1 Y E L 65 73.0 2517 10542 3.05 M10 x 2'/2 109 155 100 149 49 1.0 76.1 mm 3.000 365 2580 0.12 2 -1/8 x 2 1/24.40 6.31 4.05 5.90 1.93 2.1 76.1 2517 11476 3.05 M10 x 2'/2 112 160 103 150 49 1.0 X 3 3.500 365 3512 0.12 2 -3/8 x 2'/2 4.91 6.70 4.55 6.46 1.93 2.3 80 88.9 2517 15622 3.05 M10 x 2'/2 125 170 116 164 49 1.0 _ 4 4.560 365 5805 0.17 2 -3/8 x 2 1/2 5.95 7.82 5.54 7.47 2.14 2.9 100 114.3 2517 25822 4.32 M10 x 2'h 151 199 141 190 55 1.3 STYLE 009H JOINT ASSEMBLED 165.1 mm 6.500 290 9623 0.17 2 -1A x 3 Ya 7.84 10.93 7.55 10.85 2.11 5.69 165.1 1999 42805 4.32 M16 x 3 Ya 199 278 192 276 54 2.6 6 6.625 290 9997 0.17 1 2 -1A x 3 1/47.96 11.08 7.67 11.99 2.11 5.92 150 168.3 1999 44469 4.32 -M16 x 3 Ya 1 202 281 195 305 54 2.69 Working Pressure and End Load are total,from all internal and external loads,based on standard weight (ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.See page 1 of this document for Listed/Approved ratings on other pipe. WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown in the chart on page 1,specific to pipe schedule and size. t The allowable pipe separation dimension shown is for system layout purposes only.Fire Lock EZ couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Housing Coating: • Orange enamel(North America,Asia Pacific) • Red enamel(Europe) Optional Coatings: • Hot dipped galvanized Gasket: • Grade"E" EPDM (Type A) Fire Lock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited,and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services within the rated working pressure. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt.9UI1C® 10.61_2 REV_F FFireLock EZ° Rigid Coupling STYLE 009H GENERAL NOTES NOTE:When assembling FireLock EZ couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009H couplings, use FireLock No.006 end caps containing the"EZ" marking on the inside face or No.60 end caps con- taining the"QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009H couplings. IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009H coupling.There is no interchanging of gaskets or housings between coupling styles. USE OF FLUSHSEAL GASKETS FireLock EZ couplings are supplied with FireLock EZ Grade "E"Type A gaskets.These gaskets FOR DRY PIPE SYSTEMS include an integral pipe stop,that once installed provides the same benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard FlushSeal gaskets are not compatible and cannot be used with the FireLock EZ couplings. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.61 5731 REV F UPDATED 10/2011 �CtaLlIiC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.61 FireLock° Fittings <&> @ LPCB See Victaulic publication 10.01 for details FireLock®products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees feature CAD-developed, hydrodynamic design,affording a shorter center-to-end dimension than standard fittings.A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic IPS-sized couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536,grade 65-45-12. Fitting Coating: • Orange enamel. • Red Enamel in EMEA-l. • Optional: Hot dipped galvanized. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IC._tau IiC REV_I 10.03_1 IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 10.03 FireLock° Fittings DIMENSIONS �-CtoE� toE� I u CtoE WC - o o , •� TEto E oo tE �<e NO.001 NO.003 NO.002 NO.006 Size ,. 'Elbow 45'Elbow Straight Tee Cap Size Outside Diameter C to E Weight Each C to E Weight Each C to E Weight Each Thickness"T" Weight Each Inches Inches Inches Lbs. Inches Lbs. Inches Lbs. Inches Lbs 1 Y4 1.660 0.8 0.3 32 42.4 21 1 0.1 1'/2 1.900 - - - - - 0.82 0.4 40 48.3 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 76.1 mm 3.000 3.00 3.30 2.25 2.4 - - - - 76.1 76 1.5 57 1.1 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 L2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 108mm 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 159mm 6.250 5.50 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 1 108 9.3 176 17.6 29 5.8 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IC-tau I-id 10.03_2 REV_I IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 10.03 FireLock° Fittings FLOW DATA Size Equivalent Feet/meters of Straight Pipe t Actual No.002 Nominal Outside Elbows Straight Tee Size Diameter Inches Inches �� �0 0.Elbow Elbow Branch Run 1'/4 I 1.660 1.5 0.8 3.7 1.5 32 42.4 0.5 0.2 1.1 0.5 1 Yz 1.900 2.2 1.1 5.5 2.2 40 48.3 0.7 0.3 1.7 0.7 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 2'/2 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 108mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 159mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 t The flow data listed is based upon the pressure drop of Schedule 40 pipe. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IC-tau I-id REV-1 10.03_3 A . r�FireLockO Fittings GENERAL NOTES NOTE:When assembling FireLock EZ couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009/009WO09H couplings, use FireLock No.006 end caps containing the"EZ" marking on the inside face or No.60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.03 1539 REV I UPDATED 2/2010 �CtaLJIIC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.03 Mechanical-T° Bolted Branch Outlets SEE FM �c Vd3 LPCB SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS VNIIPO STYLES 920 AND 920N Victaulic Mechanical-TO Outlet provides a direct branch connection at any location a hole can be cut in pipe.The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently.A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size,with the same or differing branch size connections. NOTE: Style 920 and Style 920N 115 top housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded STYLES 920 AND 920N STYLE 920 CROSS outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- PATENTED ings are available,supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe.They may also be used on high density polyethylene or poly- butylene(HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating.Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 900 angle when permanently attached to the pipeline surface. Additionally,the Vic-Tap II®hole cutting tool,which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit.See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536,grade 65-45-12,with orange enamel coating. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. • Optional: Hot dipped galvanized Gasket: (Specify choice*) • Grade"E" EPDM EPDM (Green color code).Temperature range—30OF to+230°F/-340C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°F/+820C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over+150°F/+66°C or for hot dry air over+140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iIIIIC 1I1C® REV_O 11.02_1 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Size Dimensions Weight Each minal Size D. Inches +0.13 Inches Inches Inches Inches Inches Inches Lbs. L, F Y �Z� �� - - 2 x 1/2(a)d 920N 500 1.50 2.00 2.53 1.61 5.35 2.75 3.1 50 15 3450 38.1 51 64 41 136 70 1.5 V 3/4(a)a 920N 500 1.50 1.97 2.53 1.61 5.35 2.75 3.1 20 3450 38.1 50 64 41 136 70 1.5 1(a)n 920N 500 1.50 1.85 2.53 _ 1.61 5.35 2.75 3.0 w 25 3450 38.1 47 64 41 136 70 1.4 1 Y4(a)to g20N Soo 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 GROOVED OUTLET 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 C5- I? 1 Yz(a)to 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 Y �Z� 65 x Yz(a)§d 920N 500 L50 2.21 2.74 _ 1.82 143 2.0 1 A 65 a) 3450 1.5 .1 70 46 1.6 70 1.4 3/a(a)§d 920N 500 i 1.50 2.18 2.74 _ 1.82 5.64 2.75 3.0 _ LF 20 3450 38.1 55 70 46 143 70 1A T 1(a)§n 500 1.50 2.06 2.74 _ 1.82 5.64 2.75 2.9 25 920N 3450 38.1 52 70 46 143 70 1.4 1'/4 t(a)0 920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 44.5 1 58 76 83 46 160 76 1.7 1.5 FEMALE THREADED OUTLET 1 Y2 t(a)0 920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 1/2(a) 300 1.50 2.22 2.75 _ 2.25 6.46 3.18 3.9 76.1 x 15 920N 2065 38.1 56 70 57 164 81 1.8 • Provides a direct branch connection at 3/4(a) 920N 300 1.50 2.19 2.75 2.25 6.46 3.18 3.9 any location where a hole can be cut 20 2065 38.1 56 70 - 57 164 81 1.8 in the pipe 1(a) 920N 300 1.50 2.07 2.75 _ 2.25 6.46 3.18 3.8 25 2065 38.1 53 70 57 164 81 1.7 • A pressure responsive gasket provides 1'/4(a)a 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 the seal 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1 Yz(a)a 920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 • Request Publication 11.03 for 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 Mechanical-T cross assemblies 3 /2(a)0 500 1.50 2.52 3.05 _ 2.28 6.15 2.75 3.4 80 x 15 920N 3450 38.1 64 78 58 156 70 1.6 • Pressure rated up to 500 psi/3450 kPa 3/4(a)a 920N 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 on steel pipe; also available for use 20 3450 38.1 63 78 - 58 156 70 1.6 with HDPE pipe 1 (a) 920N 500 1.50 2.38 3.06 _ 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 58 156 70 1.6 • Sizes from 2 x 1/2'/50 x 15 mm 1'/4(a)to 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 through 8 x 47200 x 100 mm 32(b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 1 1/2(a)to 920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2(a)o 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 3/2 x 2 920N 500 2.50 3.00 _ 3.75 2.44 6.72 3.88 _ 3.8 90 50 3450 63.5 76 95 62 171 99 1.8 IMPORTANT NOTES: TABLE CONTINUED ON PG.3 Style 920 and Style 920N housings cannot be **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). mated to one another t Available with grooved or female threaded outlet.Specify choice on order. to achieve cross connections. t Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT clearly on order. (b)For 76.1 mm threaded outlet,specify 2'/2"BSPT clearly on order. §Vds approved for fire protection services o-PCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com ICtaUI1C° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 11.02_2 REV-0 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS St'le Max.Work Approx. Size No. Pressure@ Dimensions Weight Each Inches or +0.13 Inches Inches Inches Inches Inches inch I Lbs. Lbs. 'tl e Ma rk 920 or E Y �Z m m 920N -0.00 TABLE CONTINUED FROM PAGE 2 - 4 1/2(a)❑ 500 1.50 3.03 3.56 2.69 7.01 2.75 3.7 V 100 x 15 920N 3450 38.1 77 90 68 178 70 1.8 r I 3/4(a)❑ 920N 500 1.50 3.00 3.56 _ 2.69 7.01 2.75 3.7 20 3450 38.1 76 90 68 178 70 1.8 w 1(a)a 500 1.50 2.88 3.56 _ 2.69 7.01 2.75 3.6 _ 25 920N 3450 38.1 73 90 68 178 70 1.8 GROOVED OUTLET 1 Y4(a)tM 920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 32(b) 3450 1 44.5 78 96 102 68 178 76 1.9 1.8 1/2(a)to 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 Y Z 2(a)to 920N 4 0 63.5 83 102 100 68 17 99 2.3 4.6 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 21/2(a)t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 T 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 76.1 mm 920 500 2.75 2.88 _ 4.00 2.69 7.34 4.63 _ 6.4 w 3450 69.9 73 102 68 186 118 2.9 1? 3(a)t 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 FEMALE THREADED OUTLET 80 920 3450 88.9 84 114 105 68 196 130 3.8 2.9 1 1/4(a)o 500 1.75 3.08 3.78 _ 2.63 7.64 3.05 5.0 _ 108.0 x 32 920N 3450 44.5 78 96 67 194 78 2.3 11/2(a)o 920N 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 • Provides a direct branch connection at 40 3450 50.8 83 102 - 67 194 83 2.3 any location where a hole can be cut 2(a) 920N 500 2.50 3.25 4.00 _ 2.63 7.64 4.00 4.0 in the pipe 50 3450 63.5 83 102 67 194 1 102 1.9 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 • A pressure responsive gasket provides 3450 69.9 73 102 102 67 194 109 3.6 3.5 the seal 3(a) 920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 • Request Publication 11.03 for 5 1'/2(a)t 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 Mechanical-T cross assemblies 125 x 40 920 3450 50.8 102 121 121 80 246 94 3.4 3.4 2(a)t 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 • Pressure rated up to 500 psi/3450 kPa 50 920 3450 63.5 102 121 121 80 246 111 3.7 3.6 on steel pipe; also available for use rig(a)t 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 79 with HDPE pipe 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm a 920 500 2.75 3.75 _ 4.75 3.16 9.70 4.63 _ 8.0 • Sizes from 2 x 1/2750 x 15 mm 3450 699 95 121 80 246 118 3.6 through 8 x 47200 x 100 mm 3(a)t 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 2 500 2.50 3.75 4.50 _ 3.17 8.00 3.88 8.0 _ 133.0 x 50 920N 3450 63.5 95 114 81 203 99 3.6 3 500 3.50 3.81 5.00 _ 3.00 9.46 5.31 8.0 _ 80 920 3450 88.9 97 1 127 76 240 135 3.6 TABLE CONTINUED ON PG.4 IMPORTANT NOTES: **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet.Specify choice on order. mated to one another t Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 2/2"BSPT clearly on order. §Vds approved for fire protection services ❑LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com iiiCtaILJIiiiC® VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV_O 11.02_3 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Size Dimensions minal Size, Inches +0.13 Inches Inches Inches Inches Inches Inch'7h or es D. es y �Z� 0r mm mm mm mm mm m TABLE CONTINUED FROM PAGE 3 - 1 Yz t 500 2.00 3.78 4.50 3.30 8.23 3.25 1 7.0 i 139.7 x 40 920N 3450 50.8 96 114 - 84 209 83 3.2 - T 2 t 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 -- 50 3450 63.5 95 114 84 209 99 4.1 w 6 1 Ya(a) 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 150 x 32(b) 920N 3450 44.5 112 130 130 96 232 83 2.3 2.2 GROOVED OUTLET 1'/z(a)trl 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 130 130 96 232 83 2.4 2.3 2(a)to 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 Y Z 2 5 920 4 0 69.9 110 130 130 94 10.51 118 8.3 3.4 '� 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 V 76.1 mm 920 500 2.75 4.15 _ 5.21 3.69 10.51 4.63 _ 8.4 T 3450 69.9 105 132 94 267 118 3.8 3(a)t 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 w 80 920 3450 88.9 110 140 130 94 267 135 4.5 3.8 4(a)to 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 FEMALE THREADED OUTLET 1 1/2(a) 500 2.00 4.41 5.13 _ 3.63 9.40 3.25 7.8 159.0 x 40 920N 3450 50.8 1 112 130 92 239 83 3.5 2(a) 920N 500 2.50 4.38 5.13 _ 3.63 9.40 3.88 8.0 • Provides a direct branch connection at 50 3450 63.5 111 130 92 239 99 3.6 any location where a hole can be cut 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 in the pipe 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 • A pressure responsive gasket provides 80 920 3450 88.9 110 140 130 92 239 135 3.7 6.4 the seal 500 4.50 4.45 _ 5.38 3.63 9.40 6.12 _ 10.0 108.Omm 920 3450 114.3 1 113 137 92 239 155 4.5 • Request Publication 11.03 for 4 500 4.50 3.81 5.75 _ 3.63 9.40 6.25 18.0 _ Mechanical-T cross assemblies 100 920 3450 114.3 96.80 1 146 92 239 159 ' 8.2 TABLE CONTINUED ON PG.5 • Pressure rated up to 500 psi/3450 kPa **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). on steel pipe; also available for use t Available with grooved or female threaded outlet.Specify choice on order. with H DPE pipe t Center of run to end of fitting. • Sizes from 2 x 1/2Y50 x 15 mm # Female threaded outlets are available to NPT and BSPT specifications. through 8 x 47200 x 100 mm @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 2/2'BSPT clearly on order. §Vds approved for fire protection services a-PCB approved for fire protection services IMPORTANT NOTES: 0 Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com ICtaUI1C° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 11.02_4 REV-0 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS St le Max.Work Approx. Size No. Pressure@ Dimensions Weight Each Inches or +0.13 Inches Inches Inches Inches Inches inch I Lbs. Lbs. E Y �Z mm 920N -0.00 mm mm mm mm mm mm kg kg TABLE CONTINUED FROM PAGE 4 - 1 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 V 165.1 x 25 920N 3450 38.1 99 116 96 237 70 3.6 V - - 1�/4II 920N 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 32 3450 44.5 113 130 96 237 83 3.8 w 1/2(a)tR 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 GROOVED OUTLET 2(a)t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 69.9 110 130 132 92 267 118 3.9 3.4 Y Z 3(a)t o 920 4 0 88.9 110 140 130 92 10.51 135 10.2 8.8 80 3450 88.9 110 140 130 92 267 135 4.6 3.8 V T 4(a)to 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 TL 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 + 8 2(a)t 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 w 200 x 50 920 3450 69.9 138 157 159 122 316 1 114 5.3 5.3 2Y2(a)t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 FEMALE THREADED OUTLET 76.1 mm a 920 500 2.75 5.25 - 6.25 4.81 12.42 4.56 - 11.6 3450 69.9 133 159 122 316 116 5.3 3(a)to 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 • Provides a direct branch connection at 80 920 3450 88.9 135 165 165 122 316 135 5.7 5.3 any location where a hole can be cut 4(a)to 920 500 4.50 4.81 6.7s 6.38 4.81 12.42 6.25 is.3 12.5 in the pipe 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). • A pressure responsive gasket provides t Available with grooved or female threaded outlet.Specify choice on order. the seal t Center of run to end of fitting. • Request Publication 11.03 for # Female threaded outlets are available to NPT and BSPT specifications. Mechanical-T cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings: • Pressure rated up to 500 psi/3450 kPa (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. on steel pipe; also available for use (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. with HDPE pipe §Vds approved for fire protection services rt-PCB approved for fire protection services • Sizes from 2 x 1/2750 x 15 mm 0 Approved for use in China by Tianjin Approvals Company. through 8 x 47200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com iiictauliiiC® VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV_O 11.02_5 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point(1)and (2)for the Style 920,920N and 929 Mechanical-TO fittings can best be expressed in terms of the pressure difference across the inlet and branch.The pressure difference can be obtained from the relationship below. 4z Cv and Kv Values Values for flow of water at+60°F/+16°C are shown in the table below. Formulas for CvrKV Values: AP = Qz Where: AP = Qz Where: O C 2 Q=Flow(GPM) K z Q=Flow(m3/hr) AP=Pressure Drop(psi) V AP=Pressure Drop(Bar) Q = C x AP C =Flow Coefficient Q = K„x AP K =Flow Coefficient j Exaggerated for clarity OutletEquivalent Length of 40 Carbon Steel Pipe OUTLET SIZE (C 120)t FT C,/K,Values NOMINq AL • . � GROOVED '/z 0.840 11 15 21.3 9.4 3/4 1.050 16 20 26.7 4 13.7 1 1.315 21 25 33.7 3.. 8 1.8 1'/< 1.660 50 48 32 42.7 5/z 6 42.9 41.1 1 Y2 1.900 53 53 40 48.3 11 11 45.4 45.4 2 2.375 112 104 50 60.3 9 10/z 96 89.1 2'/2 2.875 1 119 150 65 73.0 20 12/z 102 128.5 76.1 mm 3.000 16* 161 76.1 1 1 138.1 3 3.500 249 237 80 88.9 14 15/z 213.4 203.1 4 4.500 421 401 100 114.3 20 22 360.8 343.6 t Hazen-Williams coefficient of friction is 120. *Pipe with a wall thickness of 0.165in./4.2mm. 1"FireLock-Innovative Groove System(IGS)outlet www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt.'dUI1C° 11.02_6 REV-0 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies.Contact Victaulic for performance on other pipe and the latest listings and approvals. Approval Agency Pi Run Size xt�al Outlet SizeJpe Rated Working Pressures—psi/kPa Size m Diameter S FTEW_ �O(Style920) (Style 920N) Inches/m Inches/mm *Inches mm ScPheldule UL IJLC dQ 21/2-6 2.875-6.625 All 10,40 400 400 400 290 232 362 65-150 73.0-168.3 2755 2755 2755 1 1999 1599 2496 21/2-4 2.875-4.500 All DF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2-4 2.875-4.500 All SF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 6 6.625 3,4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 3,4 30,40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10,40 400 145 200 219.1 2755 1000 8 8.625 3,4 10 300 250 145 200 219.1 2065 1724 1000 8 8.625 3,4 30,40 300 300 145 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4-8"/100- 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve.The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500psi/3450kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 47100mm, 5Y125mm,67150mm and 87200 mm diameter pipe.The Style 931 comes with a 21h"/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter(GFCI) in accordance with safety codes. For more information, refer to publication 24.01. 1 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. X.A—c—tSUIiC® REV_O 11.02_7 rM1 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 11.02 1480 REV 0 UPDATED 11/2018 L+tc�u�lC® VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 0 11.02_L �ZTISHURJOINTR) Threaded Fittings 1-01 www.shurjoint.com c&us FM 'W'. APNIINfO For Fire Protection pressure rating,listing,and approval information,visitShurjointwebsite, www.shurioint.com THREADED FITTINGS for details or contact your SHURJOINT Representative. Shurjoint offers a complete range of ductile iron Class 300 threaded fittings in sizes from %"to 2%". Material: Ductile iron ASTM A536 Gr. 65-45-12 and or Shurjoint ductile iron threaded fittings are 100% air ASTM A395 Gr. 65-45-15. tested underwater to ensure leak-free performance. Dimensions:ANSI B16.3 Class 150 except bushings and The Shurjoint ductile iron fitting series is UL listed plugs(1316.14), unions (B16.39)and companion flanges and FM approved, making them the right choice for (616.42). Please note wall thickness dimensions are fire protection and other general application services. subordinate to Shurjoint UL and FM pressure rating listings and approvals Threads:ANSI B1.20.1 NPT or ISO-7(BSPT) Finish: Black or electro-zinc plated • General Dimensions ' L These dimensions apply to all standard fittings, both straight and reducing. For center-to-face dimensions(*), - see fitting tables. Ductile Iron Class 300 threaded fittings are designed to the y. ' same dimensions as that of Class 150 malleable iron J E + H fittings.Though due to the superior strength characteristics, J ductile Iron fittings carry a much higher pressure rating. B j Laboratory tests confirm Shurjoint ductile iron fittings have T passed hydrostatic test pressures exceeding 6,000 psi/ 414 Bar,which is equal to four times the 1,500 psi/103 Bar as specified by ANSI B16.3 for 1%"—2"sizes. Size Band O.D. Band Width Thread Length(min) in in in in '/2 1.02 0.25 0.43 3/4 1.46 0.27 0.50 1 1.77 0.30 0.58 1'/4 2.15 0.34 0.67 1'/2 2.43 0.37 0.70 2 2.96 0.42 0.75 2%2 3.59 0.48 0.92 Installers who have not used DI threaded fittings before Burst pressure testing of DI threaded fittings(2") 0 should be instructed that the fittings are stronger than the pipe in most cases. In general DI threaded fittings require about a one-half turn less than cast iron fittings. Refer to the installation instructions for fiuther detail. Pressure-Temperature Ratin ANSI 11316.3&B16.14 Nom. Working Pressure • Rating @1 -G) Working Pressure Class �z —1":2000 psi/140 Bar 300 1%4"—2": 1500 psi/105 Bar 300 psi(20 Bar) 2'/2": 1000 psi/70 Bar *Proof test pressure:1.5 times the working pressure,non-shock cold water. I-01-1/6 Rev G20120315 TSHURJOINTR: Threaded Fittings 1-01 www.shugoint.com MODEL 811 ELBOW 900 Model . . 0' A--I size A Wt. BoxQ'ty in in Lbs PCs J '/2 1.12 0.25 240 L '/4 1.31 0.35 120 I 1 1.50 0.57 70 1'/4 1 1.75 1 0.97 1 40 1'/2 1 1.94 1 1.17 1 30 2 1 2.25 1 1.83 1 20 2'/2 2.70 3.34 1 10 MODEL 812 REDUCING ELBOW 900 ElbowModel 812 Reducing 90' B _ Size A B W. Box Q'ty in in in Lbs PCs ,. '/4X'/2 1.20 1.22 0.35 160 1 x'/2 1.26 1.36 0.46 110 1 x'/4 1.18 1.45 0.57 90 L P/4 x'/2 1.34 1.53 0.64 75 1'/4 x 1/4 1 1.45 1.62 0.68 60 1'/4 x 1 1.58 1.67 0.81 55 P/2 x'/2 1.41 1.66 0.84 45 1'/2 x'/4 1.52 1.75 0.90 45 1'h x 1 1.65 1.80 0.95 40 P/2 x P/4 1.82 1.88 1.10 35 2x3/4 1.60 1.97 1.19 1 30 2 x 1 1.73 2.02 1 1.47 25 2x11/2 2.02 2.16 1 1.61 20 2'/2 x 2 2.39 2.60 2.93 15 MODEL 813 ELBOW 450 ElbowModel 813 450 Size A Wt. Box Q'ty f in in Lbs PCs '/2 0.88 0.22 250 3/4 0.98 0.33 150 1 1.12 0.55 90 1'/4 1.29 0.84 50 P/2 1.43 0.92 35 2 1.68 1.63 18 2'/2 1 1.95 2.42 12 I-01-2/6 Rev.G20120315 TSHURJOINTR: Threaded Fittings 1-01 www.shugoint.com MODEL 814 TEE Model Tee - 1 Size A Wt. Box Q'ty m in Ibs PCs A '/z 1.12 0.31 150 '/a 1.31 0.48 90 1 1.50 0.81 60 1.75 1.28 35 A A� 1.94 1.72 24 01 2 2.25 2.57 12 2.70 4.44 8 MODEL 815 REDUCING TEE Model 815 Reducing Tee Size A B C W. Box in in in in Lbs PCs '/a %z 1.20 1.20 1.22 0.46 95 Yz 1 1.50 1.36 1.50 0.71 55 1 /z 1.26 1.20 1.36 0.59 80 1 '/a '/a 1.37 1.31 1.45 0.66 65 1 1.50 1.45 1.50 0.77 55 1 /z 1.26 1.26 1.36 0.64 1 65 ` '/a 1.37 1.37 1.45 0.75 60 '/z 1.34 1.26 1.53 0.79 50 1 '/a 1.45 1.37 1.62 0.88 50 1 1.58 1.50 1.67 1.01 45 1'/a 1'/a 1.75 1.67 1.75 1.25 40 '/z 1.34 1.34 1.53 0.84 45 1'/a '/a 1.45 1.45 1.62 0.99 45 1 1.58 1.58 1.67 1.12 40 '/z 1.44 1.31 1.69 0.92 40 '/a 1.50 1.37 1.75 1.01 40 1 1 1.65 1.50 1.80 1.19 30 1'/a 1.82 1.67 1.88 1.54 30 1%z 1.94 1.80 1.94 1 1.54 30 1'/ %z 1.41 1.34 1.66 1.08 40 1'A '/a 1.52 1.45 1.75 1.14 40 1 1.65 1.58 1.80 1.39 30 %z 1.41 1.41 1.66 1.10 35 1'/z '/a 1.52 1.52 1.75 1.17 35 1 1.65 1.65 1.80 1.36 30 1'/a 1.82 1.82 1.88 1.56 30 1 2 2.25 2.02 2.25 2.13 15 1'/a 2 2.25 2.10 2.25 2.22 15 %z 1.49 1.41 1.88 1.52 30 '/a 1.60 1.52 1.97 1.47 25 1'/z 1 1.73 1.65 2.02 1.63 20 2 1%z 2.02 1.94 2.16 2.09 20 2 1 2.25 2.16 2.25 2.33 15 '/z 1.49 1.49 1.88 1.56 20 1.60 1.60 1.97 1.61 20 2 1 1.73 1.73 2.02 1.80 20 P/a 1.90 1.90 2.10 2.09 20 1%z 2.02 2.02 2.16 2.24 15 2'/z 2 1 '/a 1.74 1.60 2.32 2.35 15 1-01-3/6 Rev.G 20120315 TSHURJOINT R' Threaded Fittings 1-01 www.shugant.com MODEL 815 BULLHEAD TEE Model 815 Bullhead Tee Size A B C At. Box C in in in in Lbs PCs '/4 '/4 1 1.45 1.45 1.37 0.66 65 1 1 1'/4 1.67 1.67 1.58 0.97 45 1'/z 1.80 1.80 1.65 1.15 35 1 1'/z 1.88 1.80 1.82 1.43 30 1'/4 1,/4 1%z 1.88 1 1.88 1.82 1 1.52 30 2 2.10 2.10 1.90 1.80 24 1 Yz 1'/4 2 2.16 2.10 2.02 1.94 20 1'/z 2 2.16 2.16 2.02 2.00 20 2 2 2%z 2.60 2.60 2.39 3.61 10 MODEL 816 REDUCING COUPLING Model 816 Reducing Coupling Size A Wrench Size At. Box in in in Lbs PCs : s '/4 x'/z 1.63 1'/4 0.37 150 1 x Yz 1.69 1 1/4 0.37 140 } 1 x'/4 1.37 1'/z 0.48 120 1'/4 x 3/4 2.06 1-'/z 0.59 80 1'/4 x 1 2.06 0.66 60 lYzxl 2.31 0.84 50 P/z x P/4 2.31 0.92 45 2 x 1 2.81 1.23 35 2 x 1'/4 2.81 1.28 30 2 x 1'/z 2.81 1.66 30 2'/z x 2 3.25 - 2.24 18 MODEL 817 CROSS B B--I . • - � size A B W. Box Q'ty A in in in Lbs PCs 1 1/2 1.12 1.12 0.48 90 1- 3/4 1.31 1.31 0.77 60 A 1 1.50 1.50 0.95 45 1'/4 1.75 1.75 1.43 25 1%z 1.94 1 1.94 1 1.87 1 20 2 2.25 2.25 2.86 10 A�A Model 817 Reducing Cross Size A B W. Box Qty in in in Lbs PCs 1'/xl'/a 1A 1.67 1.58 1.25 30 1'/A1 YAW 1.80 1.65 1.47 24 2x2xl xl 2.02 1.73 1.94 16 I-014/6 Rev G 20120315 TSHURJOINTR Th - " ' - ' Fittings 1-01 www.shugant.com MODEL 818 STRAIGHT COUPLING ,- Model 818 Straight Coupling Size A Wrench Size W. Box Q'ty i in in in Lbs PCs + I A /2 1.38 1'8 0.18 360 i I '/4 1.61 1%" 0.26 200 1 1.77 111/16" 0.42 110 1'/4 2.00 2" 0.57 75 1'/z 1 2.20 1 2'/4" 1 0.77 1 60 2 1 2.60 1 23/4" 1 1.17 1 30 2'/2 3.00 3%" 2.11 18 MODEL 820 CAP Model i Cap r size A VV1. Box Q'ty in m in Lbs Ya 0.89 0.14 500 I. '/4 1.00 0.20 300 1 1.18 0.33 180 1'/4 1.32 0.46 110 1'/z 1.38 1 0.57 80 2 1.48 1 0.88 1 45 2Y2 1.77 1.54 25 MODEL 825 EXTENSION PIECE Model Size A Wt. Box Q'ty in in Lbs PCs '/2 x 1'/zL 1.50 0.18 300 '/2 x 2L 2.00 0.22 250 t".., 3/4x1Y2L 1.50 0.22 250 '� 6 '/4 x 2L 2.00 0.26 200 f: AA MODEL 831 LONG STREET ELBOW 900 ElbowModel 831 Long Street • i ' all% size A B W. Box Q'ty in in in Lbs PCs i 1 x'/2M 1.50 3.00 0.66 80 g 1 x 1M 1.50 3.00 0.81 60 I-01-5/6 Rev.G 20120315 TSHURJOINTR Threaded Fittings 1-01 www.shugant.com MODEL 832 LONG STREET TEE Model 832 Long Street Tee C size A B C Wt I Box Q'ty in in in in Lbs Pes 1 x'/2XIM 1.50 1.40 3.00 0.91 50 -t-- IX1x1M 1.50 1.50 3.00 1.03 45 MODEL 827 HEX BUSHING Model 827 Hex Bushing Size A Wt. Box Q'ty in in Lbs PCs A I X'/2 1.06 0.20 280 1 x3/4 1.06 0.18 280 qW, 1'/4 X I 1.18 0.29 150 1'/2 x 1 1.26 0.53 100 Ph x P/4 1 1.26 0.37 100 2 x 1 1 1.34 0.75 80 2 x 1'/4 1 1.34 0.75 80 2 x 1'/2 1 1.34 0.64 80 MODEL 819 PLUG Model 819 Plug size A Wt. BoxQty in in Lbs PCs '/2 0.93 0.09 500 3/4 1.13 0.18 300 1 1.25 0.25 200 A 1'/4 1.36 0.42 110 1 Y2 1.45 0.59 80 2 1 1.50 1 0.95 1 45 General Notes: • Pressure ratings listed are CWP(cold water pressure)or rnaximum Aurking pressure widen the service temperature range ofthe gasket used in the coupling.This rating may occasionally differ from maximum NNurking pressures listed and/or approved by UT,ULC,and/or FM as testing conditions and test pipes differ.For additional information contact Shurjoint.. • NVhximum wutidng pressures and end loads listed are total of internal and extemal pressures and loads based on Sch. 10 steel pipe with roll grooves toANSFAWWAC606-07 specifications.For information on other pipe schedules contact Shurjoint.. • For one time field test only the maximum joint vwrking pressure may be increased 1'/2 times the figures shown. • Warning:Piping systems must always be depressurized and drained before attempting disassembly and or removal ofany components. • Shurjoint reserves the right to change specifications,designs and or standard equipment without notice and without incurring any obligations. Job Name: System No. Location: Contractor: Approved: Date: Engineer: Approved: Date: Shurjoint product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,please contact Shurjoint Technical Service.Shurjoint reserves the right to change or modify product design, construction, specifications,or materials without prior notice and without incurring any obligations to make such changes and modifications on Shurjoint products previously subsequently sold. I-01-6/6 Rev.G20120315 Agftk FIRE SPRINKLER PERMIT APPLICATION sw Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223•Phone(360)403-3551 Type of Permit: ❑ New Installation (a System Modification ❑ Phased Installation Property Address: 3310 Smokey Pt Dr Suite No.: Project Valuation: $6,435 Lot#: Parcel ID No... 00645300001300 Preferred Contact: 0 Owner 0 Applicant O Contractor Project Description: Owner Name: Blinkrock Technologies, Inc. Phone No.: Email Address: Cell No.: Mailing Address:13274 Ash Way Unit F3 city: Everett State: WA zip: 98204 Applicant Name. Burns Fire Protection Systems, Inc. Phone No.: 360-691-2235 Email Address: audra@burnsfire.com Cell No.: Mailing Address: PO Box 1110 Ci :Granite Falls State: WA Zip: 98252 Contractor Name: Burns Fire Protection Systems, Inc. Office No.: 360-691-2235 Email Address: audra@burnsfire.com Cell No.: Mailing Address: PO Box 1110 City: Granite Falls State: WA Zip: 98252 L&I Contractor License Number: BURNSFP841 DU Expiration Date: 12/31/2025 SUBMITTAL REQUIREMENTS:Provide Information on All Equipment to be Installed Prior to Installation ELECTRONIC FILES OF THE FOLLOW: ❑ Complete and Scaled Plans ❑ Hydraulic Calculations ❑ Equipment Specifications for Each Fire Sprinkler Permit Application ❑ Specification Sheets ❑ Wiring Diagrams (Point to Point Wiring) ❑ Electrical Plans,if applicable FIRE SPRINKLER SYSTEMS (105.7.1, 105.7.4, 105.7.11) **DEVICES include separate individual portions of a Fire Sprinkler System such as: Sprinklers Heads, Risers,Valves, Pull Stations,and other such devices. (Each piece is one device) PLAN REVIEW FEES Less than $5,000.00 = $100.00 $5,000.00&over—based on project valuation (Plan Review Fee is 65%of project valuation as calculated per Table 4-1) REV11.2020 Page 1 of 3 REINSPECTION/PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application-review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour(1 hour minimum) $75.00 Hydrostatic Pressure Test(1 test included per permit) $150.00 Cover Inspection (1 cover inspection included per permit) $75.00 Fire Pump (1 fire pump inspection per permit) inspection requires 2 hours $150.00 TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 13/13R) Number of Devices" Device Fee Subtotal 1to2 $ 75.00 = $ 3 to 5 $125.00 = $ 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 225.00 21 to 40 $300.00 = $ 41 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $575.00 = $ > 300 I $600.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $600.00 + $ _ $ Hydraulically Designed Systems Yes ❑ / No X Yes=Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ 225.00 NEW COMMERCIAL SYSTEM (NFPA 13/13R) Number of Devices" Device Fee Subtotal 1 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $600.00 = $ > 300 $625.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices= $625.00 + Is I _ $ Hydraulically Designed Systems Yes ❑ / No ❑ Yes =Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ RESIDENTIAL (NFPA 13D) Number of Devices" Device Fee Subtotal 1 to 10 $175.00 = $ 11 to 25 $225.00 = $ 26+ $275.00 = $ *NFPA 13D SYSTEM INSTALLED(NOT REQUIRED)Permit Fee Reduced SO% _ $ PERMIT FEE SUBTOTAL $ REV2022 Page 2 of 3 ❑ HOOD SUPPRESSION SYSTEM Type of System No. of Units Cost per Unit Subtotal Pre-Engineered x $200.00 = $ Custom Engineered x $275.00 = $ PERMIT FEE SUBTOTAL $ ❑ STANDPIPE SYSTEM Type of Standpipe No. of Units Cost per Unit Subtotal Class I-new or existing x $150.00 = $ Class II-new or existing x $150.00 = $ PERMIT FEE SUBTOTAL $ ❑ FIRE PUMP Fire Pump x $300.00 each = $ PERMIT FEE SUBTOTAL $ ❑ SPRAY BOOTHS (105.7) &INDUSTRIAL OVENS(105.7.7) NOTE.SEPARATE SPRINKLER PERMIT REQUIRED Type of Booth No.of Units Cost per Unit Subtotal Pre-Engineered w/documents x $150.00 = $ Site-built or used w/o documents x $250.00 = $ Industrial Oven x $250.00 = $ PERMIT FEE SUBTOTAL $ Plan review fee due at time of submittal TOTAL PERMIT FEE $ 225.00 PLAN REVIEW FEE $ 209.20 Processing/Technology Fee $25.00 TOTAL $459.20 1 hereby certify that I am the ❑Owner, W pplican4 ❑Contractor,and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington,and the City of Arlington. A. Dion Smith 11-06-2025 Signature Print Name Date SAVE PRINT REV2022 Page 3 of 3 • 1 Permit#: 6809 Permit Date: 11/06/25 Permit Type: FIRE SPRINKLER Project Name: Life 360 Church TI Applicant Name: Burns Fire Protection Systems, Inc. Applicant Address: PO Box 1110 Applicant, City, State, Zip: Granite Falls Contact: Audra Williams Phone: 3606912235 Email: audra@bumsfire.com Scope of Work: adding 8 heads and shortening 8 heads Valuation: 6435.00 Square Feet: 15970 Number of Stories: 1 Construction Type: lA Occupancy Group: A-1;Assembly ID Code: Permit Issued: 11/20/2025 Permit Expires: 05/19/2026 Form Permit Type: FIRE SPRINKLER Status: COMPLETE Assigned To: Hannah Hardwick Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00645300001300 3310 SMOKEY POINT DR BLINKROCK 671 Executive,Legislative& TECHNOLOGIES INC Judicial Functions Contractors Contractor Primary Contact Phone Address Contractor Type License License# Burns Fire Protection Systems Audra Williams 360-691-2235 PO Box 1110 CONSTRUCTION COA 603 467 812 CONTRACTOR Burns Fire Protection Systems Audra Williams 360-691-2235 PO Box 1110 CONSTRUCTION Labor&Industries BURNSFP841DU CONTRACTOR Burns Fire Protection Systems Audra Williams 360-691-2235 PO Box 1110 CONSTRUCTION NICET 86528 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status FS07.FIRE SPRINKLER Requesting Hydro/Cover/Final if 12/30/2025 01/16/2026 01/16/2026 FIRE Approved FINAL possible Plan Reviews Date Review Type Description Assigned To Review Status 11/07/2025 FIRE SPRINKLER BUILDING Approved 11/07/2025 FIRE SPRINKLER FIRE In Review Fees Fee Description Notes Amount Web Only-Fire System Plan Review Enter 1 if permit is for:fire alarm,or fire sprinkler $200.00 Processing/Technology $25.00 Fire Sprinkler System Commercial NFPA 13/13R $225.00 Credit Card Service $13.50 Total $463.50 Attached Letters Date Letter Description 11/19/2025 Building Permit 11/06/2025 Web Form-Building Application Payments Date Paid By Description Payment Type Accepted By Amount 11/19/2025 D Alan cc LaNay Hendrick $13.50 11/19/2025 XBP Con£249325834 $450.00 Outstanding Balance $0.00 Uploaded Files Date File Name 11/06/2025 2139fl7959cf0bb48e8lbl564ed2fc71 Life 360 Church - Sprinkler Application.pdf 11/06/2025 88fbf825b47bd6bfedl32179c8fc5fd6 Life 360 Church TI - Material Submittal.pdf 11/06/2025 06afl5b85bafl6e4d77a0b8076f7ed4e Life 360 Church.pdf m �] .27'0"► ❑ WJ J H� sC1 15 P A 6 NA •009 NA 0106'7'► Z ut PROJECT NOTES Ac1•oo�a N •605` ' ` ` o t n C'•" � w v o OCCUPANCY:A-ASSEMBLY U) W • Class m 5 ♦ Clas m 4 Clas room 3 • J -- S OCCUPANCY LOAD:561 a a 510S =30CDO.125W o 418s =30CD0.125W 418 = fD Gjkjs sroom2 Class' 1 U �M, NAC3.002,SPK6.021 11 kid °. NAC3.004,SPK6 22 3s ft= 411 s >E C AREA OF WORK:22,059 SQ FT • 14 kids .20'0"► 11 k 30CD0:5 q m1•o1, q w E ` M1.008 NAC3.007,SPK6.023N 9 11 k1 U ,\/��, Mi 010 S P NA C•011,SPK6• 5 W a SPRINKLERED:YES 24•0 s .20'0"► o, 75CD0.1 w ;°, 7scD1 sw o NW.08,SPK6.O24 SPEAKER E Q 'D"► 1 2"► STROBE E� U INSTALLATION OF A NEW FIRE ALARM S M1.012♦ U EVACUATION SYSTEM TO REPLACE THE 110CD � /NAC2.012 .13'T'► EXISTING FIRE ALARM SYSTEM. STROBE EOLR �24.(IN► .2T "► • U 1 SPK6 #74/2 FPLP p•D.11- J POWER o rn ♦ 110CD Z FACP:TO BE POWERED BY THE 120V 5 ♦ /NAC2.011 p _ Pre-school ca a i o DEDICATED CIRCUIT;IS TO HAVE TWO(2) 7scD w 3 ft 11 adults ' j N °. AC3.001,SPK6.020 82 kids o 12V 7AH BATTERIES FOR POWER BACKUP. J LLUU cD o s p11•oo7 Total people 93 le I / O w L/ J H � EVACUATION PANEL:TO BE POWERED BY � .21'9^► i1� c►2•ooa 6•o1e Q (0 w A 120V DEDICATED CIRCUIT;IS TO HAVE .13'6"► U 2 .26'10"► J TWO(2)12V 7AHBACKUp BATTERIES FOR POWER 3 # Teacher po 3oc nzsw Offia pon2sw• U o Lounge ft .': NAC2.010,5 6.019 } J r P 1 M1:#1812 FPLP W 13 people w ec Stage C STORAGE 11 CD Q G NAC2.008 U EVAC FACP OACT •00 ` r� Symbol Legend F M1•: .ZG ti'► 15c < 1 G 41 P $ GE STORAGE }I{` •007 U M1.002 SYMBOL DESCRIPTION MANUFACTURER —NUMBER OUANTm' S v 4I1� M1.006 i• / N C2.006 o ExPw.mac ..NE,M.1xoaFu M.N.—­m.PNxxm,Poox, IN—. ­MxI + E -actrical Classroom 1 / ++ /NA •005 DATE: .00M,F.EP,R x oM E Nx.omBm a3-0 0.125w 0 sq t5 �T S 3.00I,SPK6.00 CD 0.1 � 1 kid v 10/29/25 SIG3 2 8 UI °' QQ;; 1 NAC2:#14/2 FPLP T ► 0 u.LP.TxiNTERNETAxOFOLTE.MFm—MU11-1 oU.No.LU— TFE , IG•004,SPK•002 1SPK6:#14/2 FPLP It .294• Q .ao o"► EmmE.xxuxcMTonwnx wxELco PiePlwr ox TECI«aLOFEa a,nuo + ' /\ •003 i1 .4" 177 1 15C �NAC 4 S �P,P.P•�Mm.�.,,..x".,.M oMEmo��EE m,N A S (Storage °�► OP N ♦ n B NAC2.002,SPK6.016 .11'1 ► 1N DM.LMPMT—U. o»E Nxo offs 1ncD 340 ca aq z m C 75CD 0.125W 1` � / 340 capac_Ity • T / 75CD SIG3.008 1 / NAC2.001 O L N JJJ �mpp uMLEamimx.00MEEM.M+E Fuuar.mx com TecxxULUciEa sa,omru , • SIG3.008,SPK6.005 li7 P soo$gft • Toddlers ' \ NME R,w.mB,P��x„ n,�x,PNE M NMF.PR 14 klds _ _ 30C 0.125w L 2 adults T OOD G3 07,SPK6.004 '0/ FTwc,so-m.,c.nm®,m�nic,cax.,s,NE,wnm x m ^ EN SUh11•EUO NI ,O, 4}'_ 1SPK6:#14l2 FPLP 1 SPSTwc,nP..x.HmAx.,a N� Hixx Fmmre,'Fx wnM x Tvrc u Y — — M1•oo Kitchen 4' P G 424• ' 4 adults Q i1" -wlo a R M1•o1 421'4' o O G ® O _ SIG U05�SP 6-003• - �OUfld Y W P 30G 0.125W Classroom -_ LLI U U N SIG ,SPK6.006 75CD 0.125W lJ 390 Sq ft 1J W � • To rs ,°, 11 kids Cry/room N x w N 4fit3 it • 7 110CD 2W O Y D 13 a tb G3r,110,SPK6.007 n 1 adult °• 75CD 0.125W LC) W ❑ C 2a ults Storage SIG3.016,SPK6.013 LghtingBTech • I V I NAC°003,SPK6.017 = z Q a m ❑ I . U U w > d U) .15'0"► } ZO 0 w Daycare ca city75CD SIG3.017 U Y I- aQ M1.014 177CD iW 15 ad ` LL.I p Z m ❑ ° : 3 ¢ C S P SIG3.015,SPK6.012 101 kids _J cn Z Tod dl rs Total buildingcapacity < ❑ O 75CDG.125W . Total 128 Q ❑ Z 520 SIG3.011,SPK6.008 Do 61 eo le cD • 14 k ds mLAJU Q W 2 ad Its ♦ Cstorage °• 110C/DS StOra a .40 _7W IG3• 0 30C CD 0.125 /DS IG3.022 SIG3.018,SPK6.014 STROBE EOLR 15 DO.125W • • V IG3.0 4,SPK8.011 b b After Sch I kids care o 422'ocf o 710 sgft- 0 kids Present Office sU•G1a Coffee Bar front © 13M1.015 ` ' Entry 30 CD 0.125W CS= ;°, slcawla, K•'4 12'0_► NICET CERTIFIED ENGINEER INFO: 5 Babies A 30CD 0.125W- of Chef ENGINEER'DEVIN DEDMAN I IG3.012,SPKfi�S C nge FAA COMPANY CASCADIA ELECTRICAL SOLUTIONS LLC 11 h�hIQS N N ADDRESS 152G/TH STREET 3 adults • ♦ ;O,150CD MARYSVILLE,WA98270 428'0"► swot M"M:016 yyp SIG3.021 PHONE NUMBER:3606402922 2 WET INFORMATION:FIRE PROTECTION 11'4"► TERPL Mt•M:017 ENGINEERINGTECHNOLOGY '2 FIRE ALARM SYSTEMS#147961 LEVEL III SPRINKLER RISER 181'7 SIGNATURE BLOCK N Approved Steve Goforth,NCRFA FLOOR PLAN 11/26/2025 8:33:47 AM SCALE: 1/8" : 1'0" SHEET NUMBER: FA1 Q SUMMARY OF CONNECTIONS o J J H� U) rr , ANNUNCIATOR z I� 0 rrlN ~ W N 0 lH J 1�1 SYSTEM OUTPUTS J SYSTEM OUTPUTS CELL Q N�U M )CAT U N 30CD 0.125W5CD 0.1251110.125WLu LH U hsh' P't'p0}(y «Si U 4A``� 4FK C�.F��T Q 9a ?P9Q ?P9a OgTT 1 SPK6 U C ¢WFz= 1 SIG3 (n 30C 0.125MSOCD 0.125W5CD D.125V80CD 0.125W 177CD 2W75CD 0.125W 177CD 1W 30CD 0.125Y80CDD.125WICDO.125W5CD0.125W10CD 0.125MI 0.1mV80CD 0.125V KCD 0.125WSCD 0.1 OCD 0.125W V g s gpa o o, o 0 0 o c o, o o o, a o 0 0 0�s >`O j � SYAh NA,v wPh wo hw w pihQ p� 3061 pY 2 c0�'�'�' �O 2P9Q 2P9R 2P 2Cy ?T�' 3w0. 090. 9m4 hWQ yh0, q9e ygQ oiOiQ 99Q Oiro 1 SPKB 1 SIG3 U SUJmmmS V 1 J o 30CD WP11000 110CD 75CD 75CD iSCD 0.125 ISCD0.125W 75CD 15CD 15CD J oo EV ICPANEL ee ay3eea hh ti os >w a°e $ $h O SYSTEMINPUTS A B C O E F G ONP C�Q P P 53 AP AA 1 LOSS OF PRIMARY POWER 1 N °j y y y "ar "o. 2 OPEN WIREIGROUND IN CIRCUIT 0 2 1 NAC3 1 L11 N 3 ACTIVATION OF ALARM SILENCE SWITCH 00 3 J W 4 ACTIVATION OF MANUAL PULL STATION 0 4 15CD 15CD 15CD 15CD 15CD 2 2 O LU CONTINUED TO SPEAKER STROBE MAC 3 \ / \ / Q 5 ACTIVATION OF SMOKE DETECTOR 5 \ \ \ 1 NAL1 S p S p S p N e 6 ACTIVATION OF WATERFLOW SWITCH 0 000 8 J 7 ACTVATION OF TAMPER SWITCH 0 0 0 7 P\ Po >$ Ao P P P ;o �!' Q cn LU 8 ACTIVATION OF SPRINKLER SHUTOFF VALVE 0 0 0 8 2P 2P 2P ?P 1 21 SPK 1 M1 4? 4? L) X J 9 ACTIVATION OF SPRINKLER SUPERVISORY SWITCH 0 0 0 9 S p 110CD 110CD 15C00.125W 110CD 15CD 15CD 110CD 11000 0 A B C D E F / I / \ /G 07� \ / \ / ,O \ / \ / / \ / \ / \ / 2 0 O cn ,M .o FRCP F $p $ .w $p $p $p $p $p $p $p $p OPERATIONAL MATRIX p QUO PIG FF y3• $o L W LL Uh 4h Uhk' rr 4 4h ri 4h UhJ= 4h g P ST S P $Q ST Ss r Q U to Q U BATTERY CALCULATIONS FOR PANEL:FACP . FACP,REO Circuit Calculations Panel:FACP Card:00 Clrcult:NAC1 CIRCUIT CALCULATIONS PANEL:EVAC PANEL CARD:00 CIRCUIT:SIG3 O:FX400R0. PARTNO. CITY. DESCRIPTION STANDBY TOTAL STANDBY ALARM TOTAL ALARM ChOulTTyp.:No,Mnmlon .HNNc3o.dv:0c -G.Tpmol hail.PRe TOTAL PAMEL STBY TorAL PAxaLALAxxN. E:,ou DATE: PERIPHEOzaaw RALD-CEaoPHOxEMAlxoispur,NAlueoARD,AMPUFIaa,aaowoR„AUDMAxaAaTER�NIi.INOTIFlc lop Davu Part No CaApplienc.DesCwu RTDistance Current VoNeOe Voltage DEVICE PART NO RiTAPPLIANCEDESC�T DISTANCE CURRENT VOLTAGE VOLTAGE DROP 10/29/25 WHITE INCTIFICATION)„OCp O%a01N1 PANEL ELSPSTWC ELSPBTWC,BPEEANEERMTGBE,CEaING,HMH FIDEUTv'FlRE-,IGNITE INOTIFICATIOp 30- 0.0000nW O.000OmA D14MINI M AMPLIFIER RED DOOR, (m ro.0B3m ITE(NOTIFICATION)16F E ELOTWC ELSTWC,BmOBECEILING,MULTE-cAxOeu„^FlR[Llwxrt[REi5C0 O 13.000OmA IO.OBf,n rtE(NOTIFICATION)177Co aml Currem:o.0000mA STROBE FILING.MULTICANDEu,•FIRE•.WHITE,laCD IO.O3dm xITENITE GxOtipicanop 1f000 ITPmI VDrep P.NG-0ax)TT.m v.lmn.DmF:W I00Bttn UTUTCATION,,6CD Circuit Calculations Panel:FACP Card:00 Clrcult:NAC2 (..,.TV) ELSP- ELSPST ,$PEEAIteEw IBEcr�NI,xIHrIDEIIW,-FIRE-,WHITEGNOTIFICAOON)t D aBE CElu cxu11-CANDEu,^FGRELl wwIERE]scoFl (o.+1m ITE(NOTIFICATION)TBCD Cimult Typo:NOaa O. v:DC VIDE xu 00073m G- E_MBGHGAn C.bl.7a„3z3 11 Bare cwo.�ry i.mMa n e (CR M Eo�sIDRH.NO LINE, GD.OMm uT _ 00.0MOm T MO..L18, E(slGxulx�unB1dRO l0.ae33n oN(sIGxANG UNE) Device Pat NO CnA Tian-Dncrew �m0INING. Current Valli VOIta.DR TOTALINEGUIPH I ­� TOT-PGRIP-PAW 12­ - P.G. la. 01 ELSPINTRIC,SPE-EFIRTGROGE,CEILING,HIGH RDEUTT,FIRE',WHITE,TOOD PP 9 9 W (.aam ro.a6an TmAL-ININIYAM1. Io.OBOO.A I TOTALAIARMAMPS 1269.BMmw (N. lV) (°.Men Re.IITy,•FMiRE'rwn (0.116Bw lo.aT3m mnaW nma:v xn sTwc.spaexensUobe,ceiiin0,x g0 Fiaeiiry,•FIRE•,w0 (O.11Bm l0.ae3m AGINGIa.Daem ID.mun O.sBBAb cpM.I..up F.mre-amatlbyna6 .E��EME�<a�a.�aFlaE.,E�o 0.0.m M. m lO.O3ean lo.az3m BATTERY CALCULATIONS FOR PANEL:EVAC PANEL (a UNen M.a3m CHIH­ IO.012Bn ro.mM,n No:ozrlM.MASTER PANEL,MlcacvxaxE,Ma RED DDDR Rmliry.'I.RE',wn Io.Ozm IO.Omm PART NO. ON. aaT DESCRIPTION AMPLIFIER. TOTALSTANDBY ALARM TOTAL ALARM NNN,,-FIRE',wn ON q WINO M3m ro.01Bm DoTai vorep P.re.nT:a.ezx),mllvau,.+o1w,&,R ,av Q AaTExD�RAR CIRCUIT CALCULATIONS PANEL:EVAC PANEL CARD:00 CIRCUIT:SPK6 < TROBECEILING,HIGHFlO --FIRE-,WxRE(NOOFICATRN)3000 (Total W.p PBm.nHJ.57%)ZVOI .map:0.]zeev ❑ I-G.0-CAOON)ts. CABLE 7e113zON, R T ISTEDu1a Y W LMwc aiYyc.aTGBE.cEIDxcoE�cELxG.„GH,oEL�.�-FINE-,WHREwOTIFICATRN)]seO a.aaapmA M.aapbmA Circuit Calculations Panel:FACP Card:00 Circuit:NAC3 U ❑ ELSIWC ELSTWC STOUGH,CERLIG,MLAG-CARDEu,"NE-,wxITE(NOTIFICATION)7KD OGOOOmA +30.°000mA w OBE CEILING,HIGH rINEUTY,^FIRE•,WHITE(11TIFlCATIGN)15CD Cablen]B11 J3.T wIN.Rre/Cb Twlabtl Me RITEnuuAMBIEMTEM OROP:3oB > ❑ z TROBE DEALING.HIGH FIDFUTY,^FIRS•,WGE(NOTIFl-11)l CDb-dfin, DEVICE PART NO l�IGxcAPPLNNCE DEW FE DeDISTANCE WATTAGE DB DB LOSS N W xDELN,"FIRE 11TE(NOT CATION)„Oc0 D..lan Crlmna:AmbmOmmF.remre�Ll6Tn O%J3N P TO.00DD WaTTB ] Q CN Y O RED NOTIFICATION)110CD M4DB Device Part NO Appliance Des° olMDistancax Current VCIta9a VOIUgW Drop OBE CEILG,INCH FTOE.-'FIR (+') BU WA ELAWEATNRREER R. Ml E(NOTIFlc ION)3Oco 2 } m 11 TROBE EI No.HIGH FTDEutt.•FIRE•,WHITE(NOTIFICATION)TOE 0,130 WA RISTROBE CEILING,HIGH FIDEUTY,•FIR = z Q Q' 2 EL. OBE CEILING,HIGH FlDELIT7,-FlRE-,WHITE(NOTIFICATNING-B.-1 a.lib.•FIRE^,Wb (a IOun FSTwC ESPSTWC.SPEAKERMmoBE,CEIUNG,H FIDEUtt,•FIR .000pwaTTe ] 0.000z- - a ❑ OBE eaawG,wOx FlDautt,-FIRE^,WHITE INOTIFT-Na MODS+WATTS ELSPSTWC ELSFBTWC,Speax.neTrab.,C�n.e,HMO PIGGING,FIRE'.Wn 3OCD IO.Oa7an OBE CEILING,HIGH FIDELITY,•FIR \./ O W TOTAL PERPN6RU STeY G-PERPNOOALARM (a.o7asn DBE CEILING.HIGH RDEUTY,•FIR IL Lu > a.Ily,-FIRE Wx (ooam RMmOBE CEILING,HMBFIDEUTY,•FlR } z O O Esw . , US a<aihiE.w-FIR,o ,x I0.Oem , wO It Es7w.-D.Eo��a.M��1 �H ^ : xE-111 FLIx�NGHRDautt-FIR OGOON DB a gFei,FleE,wn l0.0,w Y m Q _ ry•FIRE",wn oldn U-iry, U mi. ❑ z eaa.W yrpulremem: _ __ (a'aaxn - LL - z z III,C.Gang, (a Ni 013 ELSPBTWC E 0.001d DB - � NJN 3 Q ELSFSDYC ELSPSTWC,Spa.harlstroba,crema.eRenFFm.lib.l'FIRBf Anna,76- 10.00MnENZ J ❑ BATTERY CALCULATIONS FOR TRANSPONDER:CELL COMMUNICATORabPowER 13 _ __ _ _ Q W l ❑ z PART NO. CITY. DESCRIPTION NO >F STANDBY N� TOTAL STANDBY Mu ATOALARM TOTAL ALARM Rom VDrop PWWPN: ax)Tom O,T ELSPSTwc ELPFSTwc,sPuxERMTROBE,CEILING,HIGH FIDEutt,FIR dB''1x TO.(GON NATTe U.9021 De 0.001E DB m C$ PANEL EDUPMExT FACP:TO BE POWERED BY THE 120V RSTROBE CEILING.HIGH FIDEUTy,'FIRE V) _ _ DEDICATED CIRCUIT;IS TO HAVE TWO(2) Circuit Calculations Panel:FACP Card:00 Circuit•C1 TnpBE,CEILING,HIGH FIDEUTY,•FIRE W T-PANEL STEW )GOORGG TOTAL PANEL ALURM12V 7AH BATTERIES FOR POWER BACKUP. clm.n Type:Ramylua�m a.mw CDD p 0 .0MNA NOW EGLSPV_� RlsraoBE,eeuxe,xiex ai°auTr,-aiaE ❑ GIH al" EVACUATION PANEL:TO BE POWERED BY _ D. WATTS 7a art. A 120V DEDICATED CIRCUIT;IS TO HAVE Devi- Pail NONNGN Cre Appl anfee D ee�a re'�Disfan-reRCurtent VOMaBe VOIta9e Drop Pa TWO(2)12V 7AH BATTERIES FOR POWERD. mnd:,I, :'.ON BACKUP. In ERNET AND wL «F )_ re �n Circuit Calculations Panel: :M FACP Card:00 Circuit1 _ mnaby:l.za A BATTERY CALCULATIONS FOR TRANSPONDER:ANNUNCIATOR C-11Tvp.:alan n. Bll ,Mlrepm-,S C,CLI nR nall v MB.:za.dv:Dc Amp.^B °°°°" NICET CERTIFIED ENGINEER INFO: PART NO. CITY. DESCRIPTION x -331 STANDBY TE ux TOTAL STANDBYcO uALARM TOTAL ALARM L.Flpn. I.:Amxe mmpe pe.a OennaWN. arep:,0 ENGINEER:DEVIN DEDMAN PANEL EODMMExT Devi- Part NO am Appliance DesO ure B Distance Current V.11.9e VOIta9e Drop COMPANY:CASCADIA ELECTRICAL SOLUTIONS LLC ADDRESS:152D 4TH STREET (0.0003v) MARYSVILLE,WA98270 IO.p.W) PHONE NUMBER:360 640-2922 °.ma e (D.aa3v) Symbol Legend NK;ET INFORMATION:FIRE PROTECTION ENGINEERING TECHNOLOGY mntlby-34 Hre Omi 00, ro.0a0Tv) SYMBOL DESCRIPTION MANUFACTURER PART NUMBER QUANTITY FIRE ALARM SYSTEMS#147961 LEVEL III m CUNG) ® PLSTER Rm DOOR. O.Oamn 0 mnabvn.zs AIOm,:,.zs ro.Oaa4n TUT ro.NOUVRENU­AWNUNCIATGRWITHLCDDIUN- SIGNATURE BLOCK NO CHINGIA NQQL OGUIRCOMITECHNOLOGIES G. © DOUBLE FR,, MINI DUAL WxA plo.1 HBLE PDLLa-,'I -FR 11 (CH-) M1 TVR.'c airohl, r^roMula-=oee,Rea,FME- D: ,amour,cent B.M NN aam,FIRE,wnm IC.H.) @� ELMPSTwc,ap.ax.nsboba,ceiiin9,xqx Fiaelibr,'FlnE•,wxro EUNP- GO ro.00l4n MINDIJULDIMIJIMODUHUE B'dx z (O.aaMn INPUTM.117 MIXAGH MINI DUAL MODULE 10.PC TV) ITamvDrepP.ra.m:-)T.T._olm--1pl o aN SHEET NUMBER: FA2