Loading...
HomeMy WebLinkAbout8323 172ND PL NE_BLD6686_2026 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 8323 172ND PL NE Permit#: 6686 Pare el#:01089200003100 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:GAS FURNACE SWAP Valuation: 10985.00 OWNER APPLICANT CONTRACTOR CORNERSTONE HOMES NW LLC CM HEATING CM HEATING INC PO BOX 14424 1500 INDUSTRY ST#200 1500 INDUSTRY ST STE 200 MILL CREEK,WA 98082 EVERETT EVERETT,WA 98203 4252590550 425-259-0550 LTC:CMHEAHL750LP EXP:06i'25/2027 LIC:CMHEAHL751W EXP:06/17/2027 LiC:605890285 EXP:06/17/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#- EXP: LIC#: EXP JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: 2021 STORIES: 2 CONST. TYPE: VB DWELLING UNITS: OCC GROUP: R-3;Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this pennit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this pen-nit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Govemor.The building official is authorized to suspend or revoke tivs permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THiS APPLICATION iS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. iT iS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 10/IRCi 10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return fonn and coded City of Arlington#3101. 08/26/2025 Applicant Signature Date Building Official Date CONDITIONS Adhere to approved appliances.Permit shall be onsite for inspection. Call for final inspection. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 08/26/2025 Processing/Technology $25.00 08/26/2025 Inspection $75.00 08/26/2025 Forced Ar Heat<_100 BTU/h $15.00 08/26/2025 Mechanical Base $25.00 Total Due: $140.00 Total Payment: $140.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fafl CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 8323 172ND PL NE Permit#: 6686 Pare el#:01089200003100 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:GAS FURNACE SWAP Valuation: 10985.00 OWNER APPLICANT CONTRACTOR CORNERSTONE HOMES NW LLC CM HEATING CM HEATING INC PO BOX 14424 1500 INDUSTRY ST#200 1500 INDUSTRY ST STE 200 MILL CREEK,WA 98082 EVERETT EVERETT,WA 98203 4252590550 425-259-0550 LTC:CMHEAHL750LP EXP:06i'25/2027 LIC:CMHEAHL751W EXP:06/17/2027 LiC:605890285 EXP:06/17/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#- EXP: LIC#: EXP JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: 2021 STORIES: 2 CONST. TYPE: VB DWELLING UNITS: OCC GROUP: R-3;Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this pennit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this pen-nit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Govemor.The building official is authorized to suspend or revoke tivs permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THiS APPLICATION iS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. iT iS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 10/IRCi 10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return fonn and coded City of Arlington#3101. 08/26/2025 Applicant Signature Date Building Official Date CONDITIONS Adhere to approved appliances.Permit shall be onsite for inspection. Call for final inspection. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 08/26/2025 Processing/Technology $25.00 08/26/2025 Inspection $75.00 08/26/2025 Forced Ar Heat<_100 BTU/h $15.00 08/26/2025 Mechanical Base $25.00 Total Due: $140.00 Total Payment: $140.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fafl CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 8323 172ND PL NE Permit#: 6686 Pare el#:01089200003100 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:GAS FURNACE SWAP Valuation: 10985.00 OWNER APPLICANT CONTRACTOR CORNERSTONE HOMES NW LLC CM HEATING CM HEATING INC PO BOX 14424 1500 INDUSTRY ST#200 1500 INDUSTRY ST STE 200 MILL CREEK,WA 98082 EVERETT EVERETT,WA 98203 4252590550 425-259-0550 LTC:CMHEAHL750LP EXP:06i'25/2027 LIC:CMHEAHL751W EXP:06/17/2027 LiC:605890285 EXP:06/17/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#- EXP: LIC#: EXP JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: 2021 STORIES: 2 CONST. TYPE: VB DWELLING UNITS: OCC GROUP: R-3;Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this pennit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this pen-nit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Govemor.The building official is authorized to suspend or revoke tivs permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THiS APPLICATION iS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. iT iS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 10/IRCi 10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return fonn and coded City of Arlington#3101. 08/26/2025 Applicant Signature Date Building Official Date CONDITIONS Adhere to approved appliances.Permit shall be onsite for inspection. Call for final inspection. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 08/26/2025 Processing/Technology $25.00 08/26/2025 Inspection $75.00 08/26/2025 Forced Ar Heat<_100 BTU/h $15.00 08/26/2025 Mechanical Base $25.00 Total Due: $140.00 Total Payment: $140.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fafl CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 8323 172ND PL NE Permit#: 6686 Pare el#:01089200003100 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:GAS FURNACE SWAP Valuation: 10985.00 OWNER APPLICANT CONTRACTOR CORNERSTONE HOMES NW LLC CM HEATING CM HEATING INC PO BOX 14424 1500 INDUSTRY ST#200 1500 INDUSTRY ST STE 200 MILL CREEK,WA 98082 EVERETT EVERETT,WA 98203 4252590550 425-259-0550 LTC:CMHEAHL750LP EXP:06i'25/2027 LIC:CMHEAHL751W EXP:06/17/2027 LiC:605890285 EXP:06/17/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#- EXP: LIC#: EXP JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: 2021 STORIES: 2 CONST. TYPE: VB DWELLING UNITS: OCC GROUP: R-3;Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this pennit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this pen-nit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Govemor.The building official is authorized to suspend or revoke tivs permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THiS APPLICATION iS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. iT iS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 10/IRCi 10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return fonn and coded City of Arlington#3101. 08/26/2025 Applicant Signature Date Building Official Date CONDITIONS Adhere to approved appliances.Permit shall be onsite for inspection. Call for final inspection. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 08/26/2025 Processing/Technology $25.00 08/26/2025 Inspection $75.00 08/26/2025 Forced Ar Heat<_100 BTU/h $15.00 08/26/2025 Mechanical Base $25.00 Total Due: $140.00 Total Payment: $140.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fafl RESIDENTIAL MECHANICAL APPLICATION Community and Economic Development 0- City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 •Phone(360)403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping. Please fill out all pages of this application and include all information. Type of Permit: ❑ New Installation ® Addition/Alteration/Repair ❑ Gas Piping 8323 172ND PL NE 10,985 Property Address: _ Project Valuation: Lot#: - Parcel ID No.. 01089200003100 Preferred Contact: ❑ Owner O Contractor Project Description: GAS FURNACE SWAP Owner Name: SIDWAYA OUEDRAOGO Home No.: osidwa a a 2064748489 Email Address: y @yhoo.com Cell No.: 8323 172ND PL NE ARLINGTON Mailing Address: City: State: WA zip:98223 Contractor Name: Office CM HEATING No.: 4252590550 Email Address: PERMITS@CMHEATING.COM Cell No.: - Mailing Address: 1500 INDUSTRY ST#200 City: EVERETT State: WA Zip: 98203 L&I Contractor License Number: CMHEAHL751 LW Expiration Date: 6/30/26 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Gas Piping Information ® Not Applicable ❑ CSST ❑ Brass ❑ Other Proposed Piping Material: ❑ Black Steel ❑ Galvanized Steel Proposed Piping Size: ❑ Y2" ❑ S/e" ❑ 3/4" ❑ 1" ❑ 1V2" ❑ 2" Distance from Meter to furthest Appliance: Total BTU's of all Appliances: iral permi a assessed a base fee,fee per unit, and inspection fee eview er Tajb _e,4-8 may be required for certain per mitsi- 'Type of Fixture No.of Cost per Unit Subtotal Model No. Units Additional Plan Review fees x $75.00 = Air Conditioning Unit<_ 100 Btu h x $15.00 _ ,Air Conditioning Unit>100 Btu/h x $25.00 Air Conditioning Unit>500 Btu/hp x $50.00 = ,Air Handling Units x $15.00 Base Mechanical Fee 1 x $25.00 = $25.00 Boiler<100Btu/h>3h x $15.00 REV03.2022 Pagel of 3 W idential mechanical permitswill be assessed a base fee,fee per unit,and inspection fee (plan review petA&le 4-8 may be required for certainpermits) Boiler>1 million Btu h<50h x $25.00 _ Boiler>1.5 million Btu/h<50hp x $50.00 = Boiler>100Btu/h 3-15h x $15.00 = Boiler>500Btu/h 15-30hp x $25.00 = Commercial Hoods-Type I x $25.00 = Commercial Hoods-Type II x $50.00 = Diffusers x $15.00 = Dryer Ducting x $15.00 = Ductwork(drawings required) x $25.00 = Evaporative Coolers x $15.00 = Exhaust Ventilation Fans x $15.00 = Fireplace/Insert/Stove x $15.00 = Forced Air Heat_<100 Btu/h 1 x $15.00 = 15 Forced Air Heat>100 Btu/h x $25.00 = Gas Clothes Dryer x $15.00 = Gas Fired Air Conditioning Unit<_ 100 Btu/h x $15.00 = Gas Fired Air Conditioning Unit> 100 Btu h x $25.00 = Gas Fired Air Conditioning Unit>500 Btu/hp x $50.00 = Gas Piping s 5 units x $15.00 = Gas Piping for each additional unit >5 x $2.00 = Heat Exchangers x $15.00 = Heat Pump-Condensing Unit x $25.00 = Hot Water Heat Coils x $15.00 = Miscellaneous Appliance-regulated by $15.00 mechanical code,not otherwise specified x Package Units s 100 Btu > 100 Btu x $25.00 $50.00 = Range/Cook top-Gas Fired x $15.00 = Refrigeration Unit<_100Btu h x $15.00 = Refrigeration Unit>100Btu h x $25.00 = Refrigeration.Unit>500Btu h x $50.00 = Re-inspection fee x $75.00 = Residential Range Hood Ix $15.00 = Unit Heaters:5 100 Btu h $15.00 = Unit Heaters>100 Btu h $25.00 = Variable Air Volume Boxes (part of Air $10.00 ConditioningS stem = Wall Heaters-Gas Fired $25.00 = Water Heater-Gas Fired x $25.00 = Permit Fee Inspection Fee $75.00 Processing/Technology Fee $25.00 Total I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above described property will be in accordance with the laws,rules and regulation of the State of Washington. �- SABRINA KENNARD 8/26/25 Signature Print Name Date REV2.2024 Page 2 of 3 S HEATING & AIR CONDITIONING Product Data Upflow/ Horizontal Left/Right, Dedicated Downflow Two Stage Condensing Gas Fired Furnace Upflow, Convertible to Downflow Only Horizontal Right or S9V2B040D3PSBB Horizontal Left S9V2B060D3PSBB S9V2B040U3PSBB S9V2B080D4PSBB S9V2B060U3PSBB S9V2C100D4PSBB S9V2B060U4PSBB S9V2C100D5PSBB S9V2B080U4PSBB S9V2D120D5PSBB oo O S9V2C080U5PSBB S9V2C10004PSBB S9V2C10005PSBB 0 S9V2D120U5PSBB Note:Graphics in this document are for representation only.Actual model may differ in appearance. t � • COIL REQUIREMENT! Failure to follow this Caution could result in property damage or personal injury.4GXC`and 4MXC'coils installed on upflow furnaces in vertical,horizontal left,or horizontal right orientations without a factory installed metal drain pan shield must use a MAY'FERCOLKITAA kit.Coils installed on upflow furnaces must have drain pans that are suitable for 400°F (205°C)or have a metal drain pan shield.Downflow furnaces do not require a metal drain pan shield or the use of the MAY'FERCOLKITAA kit.See Installer's Guide for more information. May2020 12-1380-1 G-EN �c icati, �S'7 iw HEATING & AIR CONDITIONING General Features NATURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Association for both natural and L.P.gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control is a solid state device which continuously monitors for presence of flame when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide additional safety. QUICK HEATING Durable,cycle tested,heavy gauge tubular stainless steel primary heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower,to increase efficiency and provide a positive discharge of gas fumes to the outside. BURNERS Multiport Inshot burners will give years of quiet and efficient service.All models can be converted to L.P.gas with LP conversion kit. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers,gas valve,flame control and includes self diagnostics for ease of service.Also contains dry contacts for EAC and HUM. ENERGY EFFICIENT OPERATION Furnace is certified by the manufacturer to leak 1%or less of nominal air conditioning CFM delivered when pressurized to .5"water column with all inlets,outlets,and drains sealed. AIR DELIVERY The variable speed blower motor has sufficient airflow for most heating and cooling requirements and will switch from heating to cooling speeds on demand from room thermostat. SECONDARY HEAT EXCHANGER The S-Series furnace has a special type 29-4CTI stainless steel secondary heat exchanger to reclaim heat from flue gases which would normally be lost. STYLING Heavy gauge steel and "wrap-around"cabinet construction is used in the cabinet with baked- on enamel finish for strength and beauty. Every orientation has at least two venting options. There are no knockouts on cabinet. FEATURES AND GENERAL OPERATION The S-Series furnace utilizes a Silicon Nitride Hot Surface Ignition system,which eliminates the waste of a constant burning pilot.The integrated system control lights the main burners upon a demand for heat from the room thermostat.Complete front service access. a. Low energy power venter b.Vent proving pressure switches. 2 12-1380-1 G-E N �c icati, �S'7 iw HEATING & AIR CONDITIONING Features and Benefits 96.0%AFUE ACROSS ALL MODELS Meets utility rebates Lowers utility bills ELECTRICALLY EFFICIENT Efficient airflow design reduces electrical energy use 34 INCH TALL Lighter,easier to move and fit into tight spaces like short basements or tight closets Works great with larger, high-efficiency coils No knockouts 3—WAY MULTI-POISE/DEDICATED DOWNFLOW 8 SKU's — Upflow/Horizontal Left/Horizontal Right 6 SKU's — Downflow Added application flexibility and reduction in specification errors AIRFLOW At least 400 CFM/ton at 0.5 in. H2O external static pressure;setup airflow options down to 290 CFM/ton REGULATORY All models are airtight; 1%or less air leakage as per ASHRAE 193 Open vestibule design provides a full 34" high open vestibule DIMENSIONS Widths are industry standard: 17.5",21",and 24.5" Depth remains approximately 28" Cabinet will be compatible with industry standard coils,as well as,other accessories INTEGRATED FURNACE CONTROL Setup/Status/Diagnostics/Digital Display No dip switches Last six errors stored Dry contact EAC and HUM connections All Molex connections; no spade terminals Low voltage labeled above and below Rain shield over IFC keeps condensate off the control TUBULAR STAINLESS STEEL PRIMARY HEAT EXCHANGER 29-4C STAINLESS STEEL SECONDARY HEAT EXCHANGER Stainless steel is a more durable,corrosive-resistant material than aluminumized steel Integrated rail system for easy access if required Reduces or eliminates need for baffles VORTICA II BLOWER, DESIGNED EXCLUSIVELY FOR THE S-SERIES FURNACE Improved airflow efficiency Durable,easy to clean,two piece housing Single piece belly band/motor arm assembly Blower deck has full-length rails for easy removal and replacement, regardless of poise 12-1380-1 G-EN 3 71* eao Silavdard® HEATING & AIR CONDITIONING Features and Benefits THREE—WAY MULTI-POISE (UPFLOW, HORIZONTAL LEFT AND RIGHT) PLUS DEDICATED DOWNFLOW Easier to specify Shipped ready to install (no kits required) Every model has at least two venting options When in horizontal,trap extends only about 2" Barbed fitting on trap at hose connection and on cabinet transition for hose has barbed fitting and clamps at both ends for leak resistance. Vent table improvements including longer vent lengths;2" pipe can be used up to 100K 4 12-1380-1 G-E N ,��xWeaq �S ida�-d HEATING & AIR CONDITIONING Accessories Table 1. Accessories Model Number Description Use with BAYHANG Horizontal Hanging Kit All Upflow Furnaces BAYVENT200B Sidewall Vent Termination Kit All Furnaces BAYVENTCN200B Sidewall Vent Termination Kit(Canada— All Furnaces CPVC) BAYAIR30AVENTA Concentric Vent Kit All Furnaces BAYAIR30CNVENT Concentric Vent Kit(Canada—CPVC) All Furnaces BAYREDUCE Reducing Coupling(CPVC) All Furnaces BAYLIFTB Dual Return Kit(B size extension) B Cabinet Upflow Furnaces BAYLIFI-C Dual Return Kit(C size extension) C Cabinet Upflow Furnaces BAYLIFI-D Dual Return Kit(D size extension) D Cabinet Upflow Furnaces BAYBASE205 Downflow Subbase All Downflow Furnaces BAYFLTR206 Filter Access Door Kit(Downflow only) All Downflow Furnaces BAYSF1165AA(a) 1"SlimFit Box with MERV 4 Filter All Upflow Furnaces BAYLPSS400* Propane Conversion Kit with Stainless Steel All Furnaces Burners BAYMFGH200B Manufactured/Mobile Housing Kit All Furnaces BAYCNDTRAP2A Inline Condensate Trap Kit used with Special All Furnaces Venting on 2"Vent Pipe BAYCNDTRAP3A Inline Condensate Trap Kit used with Special All Furnaces Venting on 3"Vent Pipe (a) Airflow greater than 1600 CFM requires dual returns 12-1380-1 G-EN 5 ,��cler�rca� �S�iaara! HEATING & AIR CONDITIONING Product Specification MODEL S9V2B040U3PSBB(a) S9V2B060U3PSBB(a) S9V2B060U4PSBB(a) S9V2B080U4PSBB(a) TYPE Upflow/Horizontal Upflow/Horizontal Upflow/Horizontal Upflow/Horizontal RATINGS(b) 1st Stage Input BTUH(ICS) 26,000 39,000 39,000 52,000 1st Stage Capacity BTUH 25,220 37,830 37,830 50,440 2nd Stage Input BTUH 40,000 60,000 60,000 80,000 2nd Stage Capacity BTUH(ICS)(c)(d) 38,800 58,200 58,200 77,600 1st Stage Temp.Rise(Min.-Max.) 25-55 25-55 25-55 30-60 2nd Stage Temp.Rise(Min.-Max.) 30-60 35-65 35-65 35-65 AFUE(%)(d) 96.0 96.0 96.0 96.0 BLOWER DRIVE DIRECT DIRECT DIRECT DIRECT Diameter—Width(In.) 11 X 8 11 X 8 11 X 8 11 X 8 No.Used 1 1 1 1 Speeds(No.) Variable Variable Variable Variable CFM vs.in.w.g. See Fan Performance See Fan Performance See Fan Performance See Fan Performance Table Table Table Table Motor HP 1/2 1/2 3/4 3/4 RPM Variable Variable Variable Variable Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 120/1/60 FLA 5.7 5.7 8.0 8.0 COMBUSTION FAN—Type Centrifugal Centrifugal Centrifugal Centrifugal Drive—No.Speeds Direct-2 Direct-2 Direct-2 Direct-2 Motor HP—RPM 3300/2600 3300/2600 3300/2600 3300/2600 Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 120/1/60 FLA 0.66 0.66 0.66 0.66 FILTER—Furnished? No No No No Type recommended High Velocity High Velocity High Velocity High Velocity Hi Vel.(No.-Size-Thk.) 1—16x25—1 in. 1—16x25—1 in. 1—16x25—1 in. 1—16x25—1 in. VENT PIPE DIAMETER—Min(in.)(e) (f) 2 Round 2 Round 2 Round 2 Round HEATEXCHANGER Type—Fired 409 Stainless Steel 409 Stainless Steel 409 Stainless Steel 409 Stainless Steel —Unfired 29-4C Stainless Steel 29-4C Stainless Steel 29-4C Stainless Steel 29-4C Stainless Steel Gauge(Fired) 20 20 20 20 ORIFICES—Main Nat.Gas Qty.—Drill Size 2-45 3-45 3-45 4-45 LP Gas Qty.—Drill Size 2-56 3-56 3-56 4-56 GAS VALVE Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage PILOT SAFETY DEVICE Type 120 V SiNi Igniter 120 V SiNi Igniter 120 V SiNi Igniter 120 V SiNi Igniter BURNERS—Type Multiport Inshot Multiport Inshot Multiport Inshot Multiport Inshot Number 2 3 3 4 POWER CONN.—V/Ph/Hz(9) 120/1/60 120/1/60 120/1/60 120/1/60 Ampacity(In Amps) 7.9 7.9 10.8 10.8 6 12-1380-1 G-E N 79 eao�Sif rod ed® HEATING & AIR CONDITIONING Product Specification MODEL S9V2B040U3PSBB(a) S9V2B060U3PSBB(a) S9V2B060U4PSBB(a) S9V2B080U4PSBB(a) Max.Overcurrent Protection(Amps) 15 15 15 15 PIPE CONN.SIZE(in.) 1/2 1/2 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD HxWxD Uncrated(In.) 34 x 17-1/2 x 28-3/4 34 x 17-1/2 x 28-3/4 34 x 17-1/2 x 28-3/4 34 x 17-1/2 x 28-3/4 Crated(In.) 35-1/2 x 19-1/2 x 30-7/8 35-1/2 x 19-1/2 x 30-7/8 35-1/2 x 19-1/2 x 30-7/8 35-1/2 x 19-1/2 x 30-7/8 WEIGHT Shipping(Lbs.)/Net(Lbs.) 122/114 127/119 130/122 135/127 (a) Meets Energy Star (b) For U.S.applications,above input ratings(BTUH)are up to 2,000 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level.For Canadian applications,above input ratings(BTUH)are up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500 feet above sea level. (0 Central Furnace heating designs are certified to ANSI Z21.47/CSA 2.3—latest edition. (d) Based on U.S.government standard tests. (e) Refer to the Vent Length Table in the Installer's Guide. M All S9V2 furnace models have a vent outlet diameter that equals 2 in. (9) The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. MODEL S9V2C080U5PSBB(a) S9V2C10004PSBB(a) S9V2C10005PSBB(a) S9V2D120U5PSBB(a) TYPE Upflow/Horizontal Upflow/Horizontal Upflow/Horizontal Upflow/Horizontal RATINGS(b) 1st Stage Input BTUH(ICS) 52,000 65,000 65,000 78,000 1st Stage Capacity BTUH 50,440 63,050 63,050 75,660 2nd Stage Input BTUH 80,000 100,000 100,000 120,000 2nd Stage Capacity BTUH(ICS)(c)(d) 77,600 97,000 97,000 116,400 1st Stage Temp.Rise(Min.-Max.) 30-60 25-55 25-55 35-65 2nd Stage Temp.Rise(Min.-Max.) 35-65 35-65 30-60 40-70 AFUE(%)(d) 96.0 96.0 96.0 96.0 BLOWER DRIVE DIRECT DIRECT DIRECT DIRECT Diameter—Width(In.) 11 X 10 11 X 10 11 X 10 11 X 10 No.Used 1 1 1 1 Speeds(No.) Variable Variable Variable Variable CFM vs.in.w.g. See Fan Performance See Fan Performance See Fan Performance See Fan Performance Table Table Table Table Motor HP 1 3/4 1 1 RPM Variable Variable Variable Variable Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 120/1/60 FLA 10.5 8.0 10.5 10.5 COMBUSTION FAN—Type Centrifugal Centrifugal Centrifugal Centrifugal Drive—No.Speeds Direct-2 Direct-2 Direct-2 Direct-2 Motor HP—RPM 3300/2600 3300/2600 3300/2600 3300/2600 Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 120/1/60 FLA 0.66 0.66 0.66 0.66 FILTER—Furnished? No No No No Type recommended High Velocity High Velocity High Velocity High Velocity Hi Vel.(No.-Size-Thk.) 1—20x25—1 in. 1—20x25—1 in. 1—20x25—1 in. 1—24x25—1 in. VENT PIPE DIAMETER—Min(in.)(e)(f) 2 Round 2 Round 2 Round 3 Round HEATEXCHANGER Type—Fired 409 Stainless Steel 409 Stainless Steel 409 Stainless Steel 409 Stainless Steel —Unfired 29-4C Stainless Steel 29-4C Stainless Steel 29-4C Stainless Steel 29-4C Stainless Steel 12-1380-1 G-EN 7 4*w a"S7iuidad HEATING & AIR CONDITIONING Product Specification MODEL S9V2C080U5PSBB(a) S9V2C10004PSBB(a) S9V2C10005PSBB(a) S9V2D120U5PSBB(a) Gauge(Fired) 20 20 20 20 ORIFICES—Main Nat.Gas Qty.—Drill Size 4-45 5-45 5-45 6-45 LP Gas Qty.—Drill Size 4-56 5-56 5-56 6-56 GAS VALVE Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage PILOT SAFETY DEVICE Type 120 V SIN!Igniter 120 V SIN!Igniter 120 V SIN!Igniter 120 V SIN!Igniter BURNERS—Type Multiport Inshot Multiport Inshot Multiport Inshot Multiport Inshot Number 4 5 5 6 POWER CONN.—V/Ph/Hz(g) 120/1/60 120/1/60 120/1/60 120/1/60 Ampacity(In Amps) 13.9 10.8 13.9 13.9 Max.Overcurrent Protection(Amps) 15 15 15 15 PIPE CONN.SIZE(in.) 1/2 1/2 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD HxWxD Uncrated(In.) 34 x 21 x 28-3/4 34 x 21 x 28-3/4 34 x 21 x 28-3/4 34 x 24-1/2 x 28-3/4 Crated(In.) 35-1/2 x 23 x 30-7/8 35-1/2 x 23 x 30-7/8 35-1/2 x 23 x 30-7/8 35-1/2 x 26-1/2 x 30-7/8 WEIGHT Shipping(Lbs.)/Net(Lbs.) 149/139 154/144 155/145 167/156 (a) Meets Energy Star (b) For U.S.applications,above input ratings(BTUH)are up to 2,000 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level.For Canadian applications,above input ratings(BTUH)are up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500 feet above sea level. (_) Central Furnace heating designs are certified to ANSI Z21.47/CSA 2.3—latest edition. (d) Based on U.S.government standard tests. (e) Refer to the Vent Length Table in the Installer's Guide. (f) All S9V2 furnace models have a vent outlet diameter that equals 2 in. (g) The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. MODEL S9V2BO4OD3PSBB(a) S9V2BO6OD3PSBB(a) S9V2B080D4PSBB(a) TYPE Downflow Downflow Downflow RATINGS(b) 1st Stage Input BTUH(ICS) 26,000 39,000 52,000 1st Stage Capacity BTUH 25,220 37,830 50,440 2nd Stage Input BTUH 40,000 60,000 80,000 2nd Stage Capacity BTUH(ICS)(c)(d) 38,800 58,200 77,600 1st Stage Temp.Rise(Min.-Max.) 25-55 25-55 30-60 2nd Stage Temp.Rise(Min.-Max.) 30-60 35-65 35-65 AFUE(%)(d) 96.0 96.0 96.0 BLOWER DRIVE DIRECT DIRECT DIRECT Diameter—Width(In.) 11 X 8 11 X 8 11 X 8 No.Used 1 1 1 Speeds(No.) Variable Variable Variable CFM vs.in.w.g. See Fan Performance See Fan Performance See Fan Performance Table Table Table Motor HP 1/2 1/2 3/4 RPM Variable Variable Variable Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 FLA 5.7 5.7 8.0 COMBUSTION FAN—Type Centrifugal Centrifugal Centrifugal 8 12-1380-1 G-E N 79 eao�Sif rod ed® HEATING & AIR CONDITIONING Product Specification MODEL S9V2BO40D3PSBB(a) S9V2BO6OD3PSBB(a) S9V2B080D4PSBB(a) Drive—No.Speeds Direct-2 Direct-2 Direct-2 Motor HP—RPM 3300/2600 3300/2600 3300/2600 Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 FLA 0.66 0.66 0.66 FILTER—Furnished? No No No Type recommended High Velocity High Velocity High Velocity Hi Vel.(No.-Size-Thk.) 2—14x20—1 in. 2—14x20—1 in. 2—14x20—1 in. VENT PIPE DIAMETER—Min(in.)(e)(f) 2 Round 2 Round 2 Round HEATEXCHANGER Type—Fired 409 Stainless Steel 409 Stainless Steel 409 Stainless Steel —Unfired 29-4C Stainless Steel 29-4C Stainless Steel 29-4C Stainless Steel Gauge(Fired) 20 20 20 ORIFICES—Main Nat.Gas Qty.—Drill Size 2-45 3-45 4-45 LP Gas Qty.—Drill Size 2-56 3-56 4-56 GAS VALVE Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage PILOT SAFETY DEVICE Type 120 V SiNi Igniter 120 V SiNi Igniter 120 V SiNi Igniter BURNERS—Type Multiport Inshot Multiport Inshot Multiport Inshot Number 2 3 4 POWER CONN.—V/Ph/Hz(9) 120/1/60 120/1/60 120/1/60 Ampacity(In Amps) 7.9 7.9 10.8 Max.Overcurrent Protection(Amps) 15 15 15 PIPE CONN.SIZE(in.) 1/2 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD Uncrated(In.) 34 x 17-1/2 x 28-3/4 34 x 17-1/2 x 28-3/4 34 x 17-1/2 x 28-3/4 Crated(In.) 35-1/2 x 19-1/2 x 30-7/8 35-1/2 x 19-1/2 x 30-7/8 35-1/2 x 19-1/2 x 30-7/8 WEIGHT Shipping(Lbs.)/Net(Lbs.) 122/114 127/119 135/127 (a) Meets Energy Star (b) For U.S.applications,above input ratings(BTUH)are up to 2,000 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level.For Canadian applications,above input ratings(BTUH)are up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500 feet above sea level. (0 Central Furnace heating designs are certified to ANSI Z21.47/CSA 2.3. (d) Based on U.S.government standard tests. (e) Refer to the Vent Length Table in the Installer's Guide. M All S9V2 furnace models have a vent outlet diameter that equals 2 in. (9) The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. 12-1380-1 G-EN 9 4*w a"S7iuidad HEATING & AIR CONDITIONING Product Specification MODEL S9V2C100D4PSBB(a) S9V2C100D5PSBB(a) S9V2D120D5PSBB(a) TYPE Downflow Downflow Downflow RATINGS(b) 1st Stage Input BTUH(ICS) 65,000 65,000 78,000 1st Stage Capacity BTUH 63,050 63,050 75,660 2nd Stage Input BTUH 100,000 100,000 120,000 2nd Stage Capacity BTUH(ICS)(c)(d) 97,000 97,000 116,400 1st Stage Temp.Rise(Min.-Max.) 25-55 25-55 35-65 2nd Stage Temp.Rise(Min.-Max.) 35-65 30-60 40-70 AFUE(%)(d) 96.0 96.0 96.0 BLOWER DRIVE DIRECT DIRECT DIRECT Diameter—Width(In.) it X 10 it X 10 it X 10 No.Used 1 1 1 Speeds(No.) Variable Variable Variable CFM vs.in.w.g. See Fan Performance See Fan Performance See Fan Performance Table Table Table Motor HP 3/4 1 1 RPM Variable Variable Variable Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 FLA 8.0 10.5 10.5 COMBUSTION FAN—Type Centrifugal Centrifugal Centrifugal Drive—No.Speeds Direct-2 Direct-2 Direct-2 Motor HP—RPM 3300/2600 3300/2600 3300/2600 Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 FLA 0.66 0.66 0.66 FILTER—Furnished? No No No Type recommended High Velocity High Velocity High Velocity Hi Vel.(No.-Size-Thk.) 2—16x20—1 in. 2—16x20—1 in. 2—16x20—1 in. VENT PIPE DIAMETER—Min(in.)(e)(f) 2 Round 2 Round 3 Round HEATEXCHANGER Type—Fired 409 Stainless Steel 409 Stainless Steel 409 Stainless Steel —Unfired 29-4C Stainless Steel 29-4C Stainless Steel 29-4C Stainless Steel Gauge(Fired) 20 20 20 ORIFICES—Main Nat.Gas Qty.—Drill Size 5-45 5-45 6-45 LP Gas Qty.—Drill Size 5-56 5-56 6-56 GAS VALVE Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage PILOT SAFETY DEVICE Type 120 V SiNi Igniter 120 V SiNi Igniter 120 V SiNi Igniter BURNERS—Type Multiport Inshot Multiport Inshot Multiport Inshot Number 5 5 6 POWER CONN.—V/Ph/Hz(9) 120/1/60 120/1/60 120/1/60 Ampacity(In Amps) 10.8 13.9 13.9 Max.Overcurrent Protection(Amps) 15 15 15 PIPE CONN.SIZE(in.) 1/2 1/2 1/2 10 12-1380-1 G-E N 79 eao�Sif rod ed® HEATING & AIR CONDITIONING Product Specification MODEL S9V2C100D4PSBB(a) S9V2C100D5PSBB(a) S9V2D120D5PSBB(a) DIMENSIONS HxWxD HxWxD HxWxD Uncrated(In.) 34 x 21 x 28-3/4 34 x 21 x 28-3/4 34 x 24-1/2 x 28-3/4 Crated(In.) 35-1/2 x 23 x 30-7/8 35-1/2 x 23 x 30-7/8 35-1/2 x 26-1/2 x 30-7/8 WEIGHT Shipping(Lbs.)/Net(Lbs.) 154/144 155/145 167/156 (a) Meets Energy Star (b) For U.S.applications,above input ratings(BTUH)are up to 2,000 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level.For Canadian applications,above input ratings(BTUH)are up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500 feet above sea level. (0 Central Furnace heating designs are certified to ANSI Z21.47/CSA 2.3. (d) Based on U.S.government standard tests. M Refer to the Vent Length Table in the Installer's Guide. M All S9V2 furnace models have a vent outlet diameter that equals 2 in. (g) The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. 12-1380-1 G-EN 11 HEATING & AIR CONDITIONING Heating and Cooling Airflow Tables Table 2. S9V2B040U3PSBB Heating Airflow S9V2B040U3PSBB Furnace Heating Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter 1st Stage Capacity=25,220 2nd Stage Capacity=38,800 Heating Airflow Target External Static Pressure Setting Airflow 0.1 0.3 0.5 0.7 0.9 CFM 468 452 437 421 406 Low 468 Temp.Rise 49 51 54 56 58 Watts 27 58 90 121 152 CFM 552 600 647 694 741 Medium Low 598 Temp.Rise 43 39 36 32 28 Heating 1st Watts 41 76 112 147 183 Stage CFM 583 635 687 739 791 Medium(a) 634 Temp.Rise 39 36 33 30 27 Watts 48 83 118 153 189 CFM 930 905 879 853 828 High 1008 Temp.Rise 25 25 26 27 27 Watts 125 178 232 285 339 CFM 633 636 639 643 646 Low 650 Temp.Rise 57 57 57 56 56 Watts 48 92 135 179 223 CFM 760 786 813 840 866 Medium Low 830 Temp.Rise 48 46 45 43 41 Heating 2nd Watts 82 132 182 232 282 Stage CFM 792 817 842 867 892 Medium(a) 880 Temp.Rise 44 44 43 43 42 Watts 94 142 189 237 284 CFM 1337 1269 1200 1132 1063 High 1400 Temp.Rise 27 29 31 32 34 Watts 1 335 376 417 458 499 (a) Factory Setting. Table 3. S9V2B040D3PSBB Heating Airflow S9V2B040D3PSBB Furnace Heating Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter 1st Stage Capacity=25,220 2nd Stage Capacity=38,800 Heating Airflow Target External Static Pressure Setting Airflow 0.1 0.3 0.5 0.7 0.9 CFM 464 453 442 431 420 Low 468 Temp.Rise 51 52 53 54 55 Watts 26 55 84 113 142 CFM 616 607 599 591 583 Medium Low(a) 634 Temp.Rise 38 38 39 40 40 Heating 1st Watts 40 78 115 152 190 Stage CFM 635 643 650 658 666 Medium 684 Temp.Rise 37 37 36 36 35 Watts 47 106 165 224 283 CFM 824 843 861 880 898 High 900 Temp.Rise 28 28 27 26 26 Watts 82 130 178 226 274 CFM 662 655 649 642 635 Low 650 Temp.Rise 54 55 55 56 56 Watts 37 79 120 162 203 CFM 811 818 826 834 841 Medium Low(a) 880 Temp.Rise 45 44 44 43 42 Heating 2nd Watts 67 121 176 230 284 Stage CFM 859 865 871 877 884 Medium 950 Temp.Rise 42 41 41 41 41 Watts 88 144 200 256 312 CFM 1082 1092 1102 1111 1121 High 1250 Temp.Rise 33 33 33 33 33 Watts 192 253 314 375 436 (a) Factory Setting. 12 12-1380-1 G-E N Amm?Ao S*odfrd® HEATING & AIR CONDITIONING Heating and Cooling Airflow Tables Table 4. S9V2B040U3PSBB/S9V2B040D3PSBB Cooling Airflow S9V2B040U3PSBB/S9V2B040D3PSBB Furnace Cooling Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter Airflow External Static Pressure Cooling Unit Outdoor Setting 0.1 0.3 0.5 0.7 0.9 (CFM/ton) Cooling 450 CFM 675 675 675 675 675 CFM/Ton Watts 47 81 121 166 215 Cooling 420 CFM 630 630 630 630 630 CFM/Ton Watts 40 72 111 154 202 Cooling 400 CFM 600 600 600 600 600 CFM/Ton Watts 36 67 105 147 193 Cooling 370 CFM 555 555 555 555 555 CFM/Ton Watts 30 60 96 136 181 Cooling 1.5 Ton Cooling 350 CFM 525 525 525 525 525 CFM/Ton Watts 27 56 90 130 174 Cooling 330 CFM 495 495 495 495 495 CFM/Ton Watts 24 51 85 124 167 Cooling 310 CFM 465 465 465 465 465 CFM/Ton Watts 21 48 80 118 161 Cooling 290 CFM 435 435 435 435 435 CFM/Ton Watts 19 44 76 113 155 Cooling 450 CFM 900 900 900 900 900 CFM/Ton Watts 94 137 186 240 298 Cooling 420 CFM 840 840 840 840 840 CFM/Ton Watts 79 120 166 218 273 Cooling 400 CFM 800 800 800 800 800 CFM/Ton Watts 70 109 154 204 258 Cooling 370 CFM 740 740 740 740 740 CFM/Ton Watts 58 95 138 185 236 Cooling 2.0 Ton Cooling 350 CFM 700 700 700 700 700 CFM/Ton Watts 51 86 1 127 173 223 Cooling 330 CFM 660 660 660 660 660 CFM/Ton Watts 44 78 118 162 211 Cooling 310 CFM 620 620 620 620 620 CFM/Ton Watts 38 71 109 152 199 Cooling 290 CFM 580 580 580 580 580 CFM/Ton Watts 33 64 101 1 142 188 Cooling 450 CFM 1125 1125 1125 1125 1125 CFM/Ton Watts 167 219 278 341 408 Cooling 420 CFM 1050 1050 1050 1050 1050 CFM/Ton Watts 139 188 244 304 368 Cooling 400 CFM 1000 1000 1000 1000 1000 CFM/Ton Watts 123 170 223 281 343 Cooling 370 CFM 925 925 1 925 925 925 CFM/Ton Watts 100 145 195 250 308 Cooling 2.5 Ton Cooling 350 CFM 875 875 875 875 875 CFM/Ton Watts 87 129 178 230 287 Cooling 330 CFM 825 825 825 825 825 CFM/Ton Watts 121 160 205 254 308 Cooling 310 CFM 775 775 775 775 775 CFM/Ton Watts 101 139 1 182 229 281 Cooling 290 CFM 725 725 725 725 725 CFM/Ton Watts 88 123 164 210 260 Cooling 450 CFM 1350 1350 1350 1298 1198 CFM/Ton Watts 272 334 402 440 450 Cooling 420 CFM 1260 1260 1260 1260 1198 CFM/Ton Watts 226 284 348 417 450 Cooling 400 CFM 1200 1200 1200 1200 1198 CFM/Ton Watts 198 254 315 381 450 Cooling 370 CFM 1110 1110 1110 1110 1110 Cooling 3.0 Ton(a) CFM/Ton Watts 161 213 271 333 399 Cooling 350 CFM 1050 1050 1050 1050 1050 CFM/Ton(a) Watts 139 188 244 304 368 Cooling 330 CFM 990 990 990 990 990 CFM/Ton Watts 119 1 166 1 219 277 1 338 Cooling 310 CFM 930 930 930 930 930 CFM/Ton Watts 102 146 197 252 311 Cooling 290 CFM 870 870 870 870 870 CFM/Ton Watts 86 128 176 229 285 (a) Factory Setting 12-1380-1 G-EN 13 Aticw"Siiwdvid HEATING & AIR CONDITIONING Heating and Cooling Airflow Tables Table 5. S9V2B060U3PSBB Heating Airflow S9V2B060U3PSBB Furnace Heating Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter 1st Stage Capacity=37,830 2nd Stage Capacity=58,200 Heating Airflow Target External Static Pressure Setting Airflow 0.1 0.3 0.5 0.7 0.9 CFM 660 658 656 654 652 Low 632 Temp.Rise 53 53 53 53 54 Watts 48 85 121 157 193 CFM 860 856 852 848 844 Medium Low(a) 814 Temp.Rise 41 41 42 42 43 Heating 1st Watts 91 128 1 164 200 236 Stage CFM 900 899 898 897 896 Medium 893 Temp.Rise 39 39 39 39 39 Watts 110 147 183 219 255 CFM 1068 1061 1054 1047 1041 High 1027 Temp.Rise 33 33 33 33 33 Watts 165 202 239 276 313 CFM 838 838 837 1 837 837 Low 800 Temp.Rise 64 64 64 64 64 Watts 81 127 172 218 264 CFM 1097 1084 1071 1058 1045 Medium Low(a) 1030 Temp.Rise 49 50 50 51 52 Heating 2nd Watts 157 209 262 314 366 Stage CFM 1140 1135 1130 1124 1119 Medium 1130 Temp.Rise 47 47 48 48 48 Watts 1 201 1 255 308 362 416 CFM 1 1289 1288 1288 1287 1287 High 1300 Temp.Rise 42 42 42 42 42 Watts 319 365 410 456 502 (a) Factory Setting. Table 6. S9V2B060D3PSBB Heating Airflow S9V2BO60D3PSBB Furnace Heating Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter ist Stage Capacity=37,830 2nd Stage Capacity=58,200 Heating Airflow Target External Static Pressure Setting Airflow 0.1 0.3 0.5 0.7 0.9 CFM 634 636 638 640 641 Low 632 Temp.Rise 55 55 55 55 55 Watts 52 93 133 174 215 CFM 712 713 714 715 716 Medium Low 711 Temp.Rise 49 49 49 49 49 Heating 1st Watts 63 106 148 190 232 Stage CFM 814 814 814 814 814 Medium(a) 814 Temp.Rise 43 43 43 43 43 Watts 88 135 181 228 274 CFM 892 892 891 890 889 High 893 Temp.Rise 39 39 39 39 39 Watts 104 145 186 227 268 CFM 800 800 801 801 801 Low 800 Temp.Rise 67 67 67 67 67 Watts 82 134 186 238 290 CFM 899 898 898 897 896 Medium Low 900 Temp.Rise 60 60 60 60 60 Heating 2nd Watts 109 163 217 271 325 Stage CFM 1028 1026 1024 1022 1019 Medium ca) 1030 Temp.Rise 52 53 53 53 53 Watts 161 210 260 310 360 CFM 1127 1124 1121 1118 1114 High 1130 Temp.Rise 1 48 48 48 48 48 Watts 1 189 1 247 1 305 1 363 1 421 (a) Factory Setting. 14 12-1380-1 G-E N Amm?Ao S*odfrd® HEATING & AIR CONDITIONING Heating and Cooling Airflow Tables Table 7. S9V2B060U3PSBB/S9V2B060D3PSBB Cooling Airflow S9V2B060U3PSBB/S9V2B060D3PSBB Furnace Cooling Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter Airflow External Static Pressure Cooling Unit Outdoor Setting 0.1 0.3 0.5 0.7 0.9 (CFM/ton) Cooling 450 CFM 675 675 675 675 675 CFM/Ton Watts 46 81 121 165 212 Cooling 420 CFM 630 630 630 630 630 CFM/Ton Watts 40 72 111 153 200 Cooling 400 CFM 600 600 600 600 600 CFM/Ton Watts 36 67 105 146 192 Cooling 370 CFM 555 555 555 555 555 CFM/Ton Watts 30 60 96 137 182 Cooling 1.5 Ton Cooling 350 CFM 525 525 525 525 525 CFM/Ton Watts 27 56 91 131 175 Cooling 330 CFM 495 495 495 495 495 CFM/Ton Watts 24 52 86 126 170 Cooling 310 CFM 465 465 465 465 465 CFM/Ton Watts 21 48 82 121 164 Cooling 290 CFM 435 435 435 435 435 CFM/Ton Watts 19 45 78 116 160 Cooling 450 CFM 900 900 900 900 900 CFM/Ton Watts 92 135 184 236 291 Cooling 420 CFM 840 840 840 840 840 CFM/Ton Watts 78 118 164 214 267 Cooling 400 CFM 800 800 800 800 800 CFM/Ton Watts 69 108 153 201 253 Cooling 370 CFM 740 740 740 740 740 CFM/Ton Watts 57 94 136 183 232 Cooling 2.0 Ton Cooling 350 CFM 700 700 700 700 700 CFM/Ton Watts 50 86 1 126 171 220 Cooling 330 CFM 660 660 660 660 660 CFM/Ton Watts 44 78 117 161 208 Cooling 310 CFM 620 620 620 620 620 CFM/Ton Watts 38 71 109 151 197 Cooling 290 CFM 580 580 580 580 580 CFM/Ton Watts 33 64 101 1 142 187 Cooling 450 CFM 1125 1125 1125 1125 1125 CFM/Ton Watts 164 216 273 334 399 Cooling 420 CFM 1050 1050 1050 1050 1050 CFM/Ton Watts 137 186 240 298 359 Cooling 400 CFM 1000 1000 1000 1000 1000 CFM/Ton Watts 121 168 220 276 335 Cooling 370 CFM 925 925 1 925 925 925 CFM/Ton Watts 99 143 192 245 302 Cooling 2.5 Ton Cooling 350 CFM 875 875 875 875 875 CFM/Ton Watts 86 128 175 227 281 Cooling 330 CFM 825 825 825 825 825 CFM/Ton Watts 74 115 160 209 262 Cooling 310 CFM 775 775 775 775 775 CFM/Ton Watts 64 102 1 146 193 244 Cooling 290 CFM 725 725 725 725 725 CFM/Ton Watts 54 91 133 178 228 Cooling 450 CFM 1350 1350 1350 1296 1218 CFM/Ton Watts 267 329 395 431 452 Cooling 420 CFM 1260 1260 1260 1260 1218 CFM/Ton Watts 222 279 342 409 452 Cooling 400 CFM 1200 1200 1200 1200 1200 CFM/Ton Watts 195 250 310 374 441 Cooling 370 CFM 1110 1110 1110 1110 1110 Cooling 3.0 Ton(a) CFM/Ton Watts 158 210 266 327 390 Cooling 350 CFM 1050 1050 1050 1050 1050 CFM/Ton(a) Watts 137 186 240 298 359 Cooling 330 CFM 990 990 990 990 990 CFM/Ton Watts 118 1 164 1 216 272 1 330 Cooling 310 CFM 930 930 930 930 930 CFM/Ton Watts 100 145 194 247 304 Cooling 290 CFM 870 870 870 870 870 CFM/Ton Watts 85 127 174 225 279 (a) Factory Setting 12-1380-1 G-EN 15 Aticw"Siiwdvid HEATING & AIR CONDITIONING Heating and Cooling Airflow Tables Table 8. S9V2B060U4PSBB Heating Airflow S9V2B060U4PSBB Furnace Heating Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter 1st Stage Capacity=37,830 2nd Stage Capacity=58,200 Heating Airflow Target External Static Pressure Setting Airflow 0.1 0.3 0.5 0.7 0.9 CFM 776 769 762 756 749 Low 782 Temp.Rise 45 45 45 45 46 Watts 70 109 149 188 227 CFM 842 823 805 786 768 Medium Low 861 Temp.Rise 42 43 43 44 44 Heating 1st Watts 88 126 164 202 240 Stage CFM 863 860 858 855 853 Medium(a) 916 Temp.Rise 41 41 41 41 41 Watts 105 143 181 219 257 CFM 1105 1084 1063 1042 1021 High 1027 Temp.Rise 32 32 33 34 34 Watts 135 173 210 248 285 CFM 1002 996 990 984 979 Low 990 Temp.Rise 55 55 55 55 55 Watts 126 172 219 266 313 CFM 1130 1117 1105 1092 1079 Medium Low 1090 Temp.Rise 49 49 49 50 50 Heating 2nd Watts 160 206 253 300 347 Stage CFM 1139 1133 1128 1122 1116 Medium(a) 1160 Temp.Rise 48 48 49 49 49 Watts 181 231 281 331 381 CFM 1319 1307 1295 1283 1272 High 1300 Temp.Rise 41 42 42 42 43 Watts 1 246 300 353 407 461 (a) Factory Setting. 16 12-1380-1 G-E N Amm?Ao S*odfrd® HEATING & AIR CONDITIONING Heating and Cooling Airflow Tables Table 9. S9V2B060U4PSBB Cooling Airflow S9V2B060U4PSBB Furnace Cooling Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter Airflow External Static Pressure Cooling Unit Outdoor Setting (CFM/ton) 0.1 0.3 0.5 0.7 0.9 Cooling 450 CFM 1125 1125 1125 1125 1125 CFM/Ton Watts 154 205 261 319 381 Cooling 420 CFM 1050 1050 1050 1050 1050 CFM/Ton Watts 128 177 229 285 343 Cooling 400 CFM 1000 1000 1000 1000 1000 CFM/Ton Watts 113 159 210 264 320 Cooling 370 CFM 925 925 925 925 925 CFM/Ton Watts 93 136 184 234 288 Cooling 2.5 Ton Cooling 350 CFM 875 875 875 875 875 CFM/Ton Watts 81 122 168 217 269 Cooling 330 CFM 825 825 825 825 825 CFM/Ton Watts 70 109 153 200 251 Cooling 310 CFM 775 775 775 775 775 CFM/Ton Watts 60 97 139 185 234 Cooling 290 CFM 725 725 725 725 725 CFM/Ton Watts 51 87 127 171 219 Cooling 450 CFM 1350 1350 1350 1350 1350 CFM/Ton Watts 250 312 377 445 515 Cooling 420 CFM 1260 1260 1260 1260 1260 CFM/Ton Watts 208 265 326 390 457 Cooling 400 CFM 1200 1200 1200 1200 1200 CFM/Ton Watts 182 237 296 357 422 Cooling 370 CFM 1110 1110 1110 1110 1110 CFM/Ton Watts 148 199 254 312 373 Cooling 3.0 Ton Cooling 350 CFM 1050 1050 1050 1050 1050 CFM/Ton Watts 128 177 229 285 343 Cooling 330 CFM 490 990 990 990 990 CFM/Ton Watts 110 156 206 260 316 Cooling 310 CFM 930 930 930 930 930 CFM/Ton Watts 94 138 185 236 290 Cooling 290 CFM 870 870 870 870 870 CFM/Ton Watts 80 121 166 215 267 Cooling 450 CFM 1575 1575 1575 1575 1575 CFM/Ton Watts 382 453 528 606 686 Cooling 420 CFM 1470 1470 1470 1470 1470 CFM/Ton Watts 316 382 453 526 602 Cooling 400 CFM 1400 1400 1400 1400 1400 CFM/Ton Watts 276 340 407 477 550 Cooling 370 CFM 1295 1295 1295 1295 1295 CFM/Ton Watts 224 283 345 411 479 Cooling 3.5 Ton Cooling 350 CFM 1225 1225 1225 1225 1225 CFM/Ton Watts 193 249 308 1 371 436 Cooling 330 CFM 1155 1155 1155 1155 1155 CFM/Ton Watts 165 218 274 334 397 Cooling 310 CFM 1085 1085 1085 1085 1085 CFM/Ton Watts 140 190 243 301 360 Cooling 290 CFM 1015 1015 1015 1015 1015 CFM/Ton Watts 118 165 216 270 327 Cooling 450 CFM 1800 1800 1730 1670 1600 CFM/Ton Watts 554 636 656 686 708 Cooling 420 CFM 1680 1680 1680 1670 1600 CFM/Ton Watts 457 533 613 686 708 Cooling 400 CFM 1600 1600 1600 1600 1600 CFM/Ton Watts 399 472 548 626 708 Cooling 370 CFM 1480 1480 1480 1480 1480 Cooling 4.0 Ton(a) CFM/Ton Watts 322 389 459 533 609 Cooling 350 CFM 1400 1400 1400 1400 1400 CFM/Ton(a) Watts 276 340 407 477 550 Cooling 330 CFM 1320 1320 1320 1320 1320 CFM/Ton Watts 236 296 359 426 495 Cooling 310 CFM 1240 1240 1240 1240 1240 CFM/Ton Watts 1 199 256 316 379 445 Cooling 290 CFM 1160 1160 1160 1160 1160 CFM/Ton Watts 167 220 277 337 399 (a) Factory Setting 12-1380-1 G-EN 17 Aticw"Siiwdvid HEATING & AIR CONDITIONING Heating and Cooling Airflow Tables Table 10. S9V2B080U4PSBB Heating Airflow S9V2B080U4PSBB Furnace Heating Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter 1st Stage Capacity=50,440 2nd Stage Capacity=77,600 Heating Airflow Target External Static Pressure Setting Airflow 0.1 0.3 0.5 0.7 0.9 CFM 914 882 849 816 783 Low 864 Temp.Rise 51 53 55 57 59 Watts 90 131 172 213 255 CFM 940 912 885 858 831 Medium Low(a) 907 Temp.Rise 50 51 53 54 56 Heating 1st Watts 104 141 178 215 253 Stage CFM 983 932 881 830 779 Medium 958 Temp.Rise 47 50 53 55 58 Watts 118 151 184 218 251 CFM 1029 1068 1107 1146 1185 High 1051 Temp.Rise 45 44 42 40 39 Watts 155 195 235 275 314 CFM 1207 1206 1205 1204 1203 Low 1200 Temp.Rise 60 60 60 60 60 Watts 206 258 309 361 412 CFM 1260 1261 1262 1263 1264 Medium Low(a) 1260 Temp.Rise 57 57 57 57 57 Heating 2nd Watts 232 287 342 397 452 Stage CFM 1360 1347 1333 1320 1306 Medium 1330 Temp.Rise 53 53 54 54 55 Watts 263 322 380 439 1 497 CFM 1420 1439 1458 1477 1496 High 1460 Temp.Rise 51 50 49 49 48 Watts 1 377 433 489 546 602 (a) Factory Setting. Table 11. S9V2B080D4PSBB Heating Airflow S9V2B080D4PSBB Furnace Heating Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter 1st Stage Capacity=50,440 2nd Stage Capacity= 77,600 Heating Airflow Target External Static Pressure Setting Airflow 0.1 0.3 0.5 0.7 0.9 CFM 770 770 770 770 770 Low 864 Temp.Rise 61 61 61 61 61 Watts 72 118 164 210 256 CFM 809 809 809 809 809 Medium Low(a) 907 Temp.Rise 58 58 58 58 58 Heating 1st Watts 88 134 180 227 273 Stage CFM 854 854 854 854 854 Medium 958 Temp.Rise 54 54 54 54 54 Watts 1O1 150 198 247 296 CFM 993 993 993 993 993 High 1051 Temp.Rise 47 47 47 47 47 Watts 133 186 239 292 346 CFM 1082 1082 1082 1082 1082 Low 1200 Temp.Rise 66 66 66 66 66 Watts 181 239 298 357 416 CFM 1190 1190 1190 1190 1190 Medium Low(a) 1260 Temp.Rise 59 59 59 59 59 Heating 2nd Watts 206 268 329 390 451 Stage CFM 1225 1225 1225 1225 1225 Medium 1330 Temp.Rise 58 58 58 58 58 Watts 239 303 367 431 495 CFM 1227 1 1227 1227 1227 1227 High 1480 Temp.Rise 57 1 57 57 57 57 Watts 320 1 390 460 530 600 (a) Factory Setting. 18 12-1380-1 G-E N Amm?Ao S*odfrd® HEATING & AIR CONDITIONING Heating and Cooling Airflow Tables Table 12. S9V2B080U4PSBB/S9V2B080D4PSBB Cooling Airflow S9V2B080U4PSBB/S9V2B080D4PSBB Furnace Cooling Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter Airflow External Static Pressure Cooling Unit Outdoor Setting 0.1 0.3 0.5 0.7 0.9 (CFM/ton) Cooling 450 CFM 1125 1125 1125 1125 1125 CFM/Ton Watts 155 205 259 316 376 Cooling 420 CFM 1050 1050 1050 1050 1050 CFM/Ton Watts 130 177 228 282 340 Cooling 400 CFM 1000 1000 1000 1000 1000 CFM/Ton Watts 115 160 209 262 317 Cooling 370 CFM 925 925 925 925 925 CFM/Ton Watts 94 136 183 233 286 Cooling 2.5 Ton Cooling 350 CFM 875 875 875 875 875 CFM/Ton Watts 82 122 167 216 267 Cooling 330 CFM 825 825 825 825 825 CFM/Ton Watts 71 1 110 153 199 249 Cooling 310 CFM 775 775 775 775 775 CFM/Ton Watts 61 98 139 184 233 Cooling 290 CFM 725 725 725 725 725 CFM/Ton Watts 52 87 127 171 218 Cooling 450 CFM 1350 1350 1350 1350 1350 CFM/Ton Watts 252 311 374 440 508 Cooling 420 CFM 1260 1260 1260 1260 1260 CFM/Ton Watts 209 265 324 386 451 Cooling 400 CFM 1200 1200 1200 1200 1200 CFM/Ton Watts 184 237 294 354 416 Cooling 370 CFM 1110 1110 1110 1110 1110 CFM/Ton Watts 150 199 253 309 369 Cooling 3.0 Ton Cooling 350 CFM 1050 1050 1050 1050 1050 CFM/Ton Watts 130 177 1 228 282 340 Cooling 330 CFM 990 990 990 990 990 CFM/Ton Watts 112 156 205 258 313 Cooling 310 CFM 930 930 930 930 930 CFM/Ton Watts 95 138 185 235 288 Cooling 290 CFM 870 870 870 870 870 CFM/Ton Watts 81 121 166 1 214 265 Cooling 450 CFM 1575 1575 1575 1575 1575 CFM/Ton Watts 383 452 524 599 676 Cooling 420 CFM 1470 1470 1470 1470 1470 CFM/Ton Watts 317 382 449 520 593 Cooling 400 CFM 1400 1400 1400 1400 1400 CFM/Ton Watts 278 339 404 472 542 Cooling 370 CFM 1295 1295 1295 1295 1295 CFM/Ton Watts 225 282 343 407 473 Cooling 3.5 Ton Cooling 350 CFM 1225 1225 1225 1225 1225 CFM/Ton Watts 194 248 306 367 431 Cooling 330 CFM 1155 1155 1155 1155 1155 CFM/Ton Watts 166 218 273 331 392 Cooling 310 CFM 1085 1085 1085 1085 1085 CFM/Ton Watts 141 190 242 298 356 Cooling 290 CFM 1015 1015 1015 1015 1015 CFM/Ton Watts 119 165 215 268 324 Cooling 450 CFM 1800 1784 1746 1665 1581 CFM/Ton Watts 555 619 665 674 681 Cooling 420 CFM 1680 1680 1680 1665 1581 CFM/Ton Watts 458 531 608 674 681 Cooling 400 CFM 1600 1600 1600 1600 1600 CFM/Ton Watts 400 470 543 619 697 Cooling 370 CFM 1480 1480 1480 1480 1480 Cooling 4.0 Ton(a) CFM/Ton Watts 323 388 456 527 600 Cooling 350 CFM 1400 1400 1400 1400 1400 CFM/Ton(a) Watts 278 339 404 472 542 Cooling 330 CFM 1320 1320 1320 1320 1320 CFM/Ton Watts 237 295 357 421 488 Cooling 310 CFM 1240 1240 1240 1240 1240 CFM/Ton Watts 201 255 314 375 439 Cooling 290 CFM 1160 1160 1160 1160 1160 CFM/Ton Watts 168 220 275 334 395 (a) Factory Setting 12-1380-1 G-EN 19 Aticw"Siiwdvid HEATING & AIR CONDITIONING Heating and Cooling Airflow Tables Table 13. S9V2C080U5PSBB Heating Airflow S9V2C080U5PSBB Furnace Heating Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter 1st Stage Capacity=50,440 2nd Stage Capacity=77,600 Heating Airflow Target External Static Pressure Setting Airflow 0.1 0.3 0.5 0.7 0.9 CFM 837 870 902 934 967 Low 857 Temp.Rise 55 53 51 50 48 Watts 65 112 160 208 256 CFM 997 1015 1033 1050 1068 Medium Low(a) 1044 Temp.Rise 46 45 45 44 43 Heating 1st Watts 102 155 209 263 316 Stage CFM 1067 1094 1121 1148 1175 Medium 1123 Temp.Rise 43 42 41 40 39 Watts 123 180 236 293 350 CFM 1420 1416 1411 1407 1402 High 1498 Temp.Rise 32 33 33 33 34 Watts 238 320 402 485 567 CFM 1129 1148 1168 1188 1208 Low 1190 Temp.Rise 63 62 61 60 59 Watts 127 195 263 331 399 CFM 1387 1395 1404 1412 1420 Medium Low(a) 1450 Temp.Rise 52 51 51 51 51 Heating 2nd Watts 248 310 372 434 496 Stage CFM 1484 1498 1512 1525 1539 Medium 1560 Temp.Rise 48 48 47 47 47 Watts 281 358 435 512 589 CFM 1954 1956 1959 1961 1964 High 2080 Temp.Rise 37 37 37 37 37 Watts 1 597 732 866 1001 1 1135 (a) Factory Setting. 20 12-1380-1 G-E N Amm?Ao S*odfrd® HEATING & AIR CONDITIONING Heating and Cooling Airflow Tables Table 14. S9V2C080U5PSBB Cooling Airflow S9V2C080U5PSBB Furnace Cooling Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter Airflow External Static Pressure Cooling Unit Outdoor Setting 0.1 0.3 0.5 0.7 0.9 (CFM/ton) Cooling 450 CFM 1575 1575 1575 1575 1575 CFM/Ton Watts 279 351 426 504 584 Cooling 420 CFM 1470 1470 1470 1470 1470 CFM/Ton Watts 233 300 370 443 519 Cooling 400 CFM 1400 1400 1400 1400 1400 CFM/Ton Watts 205 269 336 406 478 Cooling 370 CFM 1295 1295 1295 1295 1295 CFM/Ton Watts 168 227 289 355 423 Cooling 3.5 Ton Cooling 350 CFM 1225 1225 1225 1225 1225 CFM/Ton Watts 145 201 261 324 389 Cooling 330 CFM 1155 1155 1155 1155 1155 CFM/Ton Watts 125 178 235 295 358 Cooling 310 CFM 1085 1085 1085 1085 1085 CFM/Ton Watts 107 157 211 269 329 Cooling 290 CFM 1015 1015 1015 1015 1015 CFM/Ton Watts 91 138 189 244 302 Cooling 450 CFM 1800 1800 1800 1800 1800 CFM/Ton Watts 399 482 567 655 745 Cooling 420 CFM 1680 1680 1680 1680 1680 CFM/Ton Watts 332 409 488 571 655 Cooling 400 CFM 1600 1600 1600 1600 1600 CFM/Ton Watts 291 364 441 519 600 Cooling 370 CFM 1480 1480 1480 1480 1480 CFM/Ton Watts 237 305 375 449 524 Cooling 4.0 Ton Cooling 350 CFM 1400 1400 1400 1400 1400 CFM/Ton Watts 205 269 336 406 478 Cooling 330 CFM 1320 1320 1320 1320 1320 CFM/Ton Watts 176 236 300 367 436 Cooling 310 CFM 1240 1240 1240 1240 1240 CFM/Ton Watts 150 207 267 330 396 Cooling 290 CFM 1160 1160 1160 1160 1160 CFM/Ton Watts 127 180 237 297 360 Cooling 450 CFM 2025 2025 2025 2025 2020 CFM/Ton Watts 550 643 740 838 934 Cooling 420 CFM 1890 1890 1890 1890 1890 CFM/Ton Watts 456 543 632 1 725 819 Cooling 400 CFM 1800 1800 1800 1800 1800 CFM/Ton Watts 399 482 567 655 745 Cooling 370 CFM 1665 1665 1665 1665 1665 CFM/Ton Watts 324 400 479 561 645 Cooling 4.5 Ton Cooling 350 CFM 1575 1575 1575 1575 1575 CFM/Ton Watts 279 351 426 504 584 Cooling 330 CFM 1485 1485 1485 1485 1485 CFM/Ton Watts 239 307 378 451 527 Cooling 310 CFM 1395 1395 1395 1395 1395 CFM/Ton Watts 203 267 334 403 476 Cooling 290 CFM 1305 1305 1305 1305 1305 CFM/Ton Watts 171 231 294 360 428 Cooling 450 CFM 2250 2250 1 2250 2150 2020 CFM/Ton Watts 734 839 947 955 934 Cooling 420 CFM 2100 2100 2100 2100 2020 CFM/Ton Watts 607 705 805 907 934 Cooling 400 CFM 2000 2000 2000 2000 2000 CFM/Ton Watts 531 624 719 816 916 Cooling 370 CFM 1850 1850 1850 1850 1850 Cooling 5.0 Ton(a) CFM/Ton Watts 430 1 515 603 693 785 Cooling 350 CFM 1750 1750 1750 1750 1750 CFM/Ton(a) Watts 370 450 533 619 707 Cooling 330 CFM 1650 1650 1650 1650 1650 CFM/Ton Watts 316 392 470 551 634 Cooling 310 CFM 1550 1550 1550 1550 1550 CFM/Ton Watts 268 339 412 489 568 Cooling 290 CFM 1 1450 1450 1450 1450 1450 CFM/Ton Watts 225 1 291 360 432 1 507 (a) Factory Setting 12-1380-1 G-EN 21 Aticw"Siiwdvid HEATING & AIR CONDITIONING Heating and Cooling Airflow Tables Table 15. S9V2C10004PSBB Heating Airflow S9V2C10004PSBB Furnace Heating Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter 1st Stage Capacity=63,050 2nd Stage Capacity=97,000 Heating Airflow Target External Static Pressure Setting Airflow 0.1 0.3 0.5 0.7 0.9 CFM 1139 1128 1118 1107 1097 Low 1146 Temp.Rise 52 52 52 52 53 Watts 139 192 246 299 352 CFM 1275 1260 1244 1229 1213 Medium Low 1280 Temp.Rise 46 47 47 48 48 Heating 1st Watts 187 239 291 343 395 Stage CFM 1304 1287 1270 1253 1236 Medium 1359 Temp.Rise 45 46 46 47 47 Watts 211 272 332 393 454 CFM 1437 1436 1436 1435 1434 High(a) 1446 Temp.Rise 41 41 41 41 41 Watts 255 311 367 423 479 CFM 1449 1445 1440 1435 1431 Low 1450 Temp.Rise 63 63 63 63 63 Watts 272 336 401 466 531 CFM 1664 1651 1639 1626 1613 Medium Low 1620 Temp.Rise 55 55 55 56 56 Heating 2nd Watts 354 424 493 562 631 Stage CFM 1694 1687 1681 1674 1667 Medium 1720 Temp.Rise 53 54 1 54 1 54 1 54 Watts 408 484 559 635 711 CFM 1849 1827 1805 1783 1761 High(a) 1830 Temp.Rise 49 50 50 51 51 Watts 525 579 633 687 741 (a) Factory Setting. Table 16. S9V2C100D4PSBB Heating Airflow S9V2C100D4PSBB Furnace Heating Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter 1st Stage Capacity=63,050 2nd Stage Capacity=97,000 Heating Airflow Target External Static Pressure Setting Airflow 0.1 0.3 0.5 0.7 0.9 CFM 1068 1048 1029 1009 989 Low 1080 Temp.Rise 55 57 60 63 66 Watts 101 151 201 251 301 CFM 1158 1113 1068 1023 978 Medium Low 1166 Temp.Rise 51 53 55 57 59 Heating 1st Watts 115 172 229 285 342 Stage CFM 1326 1272 1218 1164 1111 Medium(a) 1318 Temp.Rise 46 48 50 51 53 Watts 153 206 259 312 365 CFM 1312 1270 1229 1188 1147 High 1361 Temp.Rise 46 47 47 48 49 Watts 166 221 276 331 387 CFM 1514 1478 1441 1404 1367 Low 1500 Temp.Rise 58 60 61 63 64 Watts 223 297 370 443 516 CFM 1620 1588 1556 1523 1491 Medium Low 1620 Temp.Rise 55 56 57 58 59 Heating 2nd Watts 276 345 415 484 553 Stage CFM 1768 1746 1724 1702 1620 Medium(a) 1830 Temp.Rise 50 51 1 52 53 1 53 Watts 372 446 520 594 668 CFM 1810 1783 1756 1729 1702 High 1890 Temp.Rise 49 50 51 52 52 Watts 405 476 548 677 695 (a) Factory Setting. 22 12-1380-1 G-E N Amm?Ao S*odfrd® HEATING & AIR CONDITIONING Heating and Cooling Airflow Tables Table 17. S9V2C10004PSBB/S9V2C100D4PSBB Cooling Airflow S9V2C10004PSBB/S9V2C100D4PSBB Furnace Cooling Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter Airflow External Static Pressure Cooling Unit Outdoor Setting 0.1 0.3 0.5 0.7 0.9 (CFM/ton) Cooling 450 CFM 1125 1125 1125 1125 1125 CFM/Ton Watts 123 178 236 296 360 Cooling 420 CFM 1050 1050 1050 1050 1050 CFM/Ton Watts 104 156 210 268 329 Cooling 400 CFM 1000 1000 1000 1000 1000 CFM/Ton Watts 93 142 195 251 309 Cooling 370 CFM 925 925 925 925 925 CFM/Ton Watts 77 123 173 226 282 Cooling 2.5 Ton Cooling 350 CFM 875 875 875 875 875 CFM/Ton Watts 68 112 160 211 265 Cooling 330 CFM 825 825 825 825 825 CFM/Ton Watts 60 1 102 147 196 249 Cooling 310 CFM 775 775 775 775 775 CFM/Ton Watts 52 92 135 183 234 Cooling 290 CFM 725 725 725 725 725 CFM/Ton Watts 45 83 125 170 220 Cooling 450 CFM 1350 1350 1350 1350 1350 CFM/Ton Watts 194 259 326 396 468 Cooling 420 CFM 1260 1260 1260 1260 1260 CFM/Ton Watts 163 224 287 353 422 Cooling 400 CFM 1200 1200 1200 1200 1200 CFM/Ton Watts 144 202 263 327 393 Cooling 370 CFM 1110 1110 1110 1110 1110 CFM/Ton Watts 119 173 231 291 354 Cooling 3.0 Ton Cooling 350 CFM 1050 1050 1050 1050 1050 CFM/Ton Watts 104 156 210 1 268 329 Cooling 330 CFM 990 1 990 990 990 990 CFM/Ton Watts 91 140 192 247 306 Cooling 310 CFM 930 930 930 930 930 CFM/Ton Watts 78 125 174 228 284 Cooling 290 CFM 870 870 870 870 870 CFM/Ton Watts 67 ill 158 209 264 Cooling 450 CFM 1575 1575 1575 1 1575 1575 CFM/Ton Watts 289 363 440 519 600 Cooling 420 CFM 1470 1470 1470 1470 1470 CFM/Ton Watts 241 311 383 458 535 Cooling 400 CFM 1400 1400 1400 1400 1400 CFM/Ton Watts 213 280 349 421 495 Cooling 370 CFM 1295 1295 1295 1295 1295 CFM/Ton Watts 175 237 302 369 439 Cooling 3.5 Ton Cooling 350 CFM 1225 1225 1225 1225 1225 CFM/Ton Watts 152 211 273 338 405 Cooling 330 CFM 1155 1155 1155 1155 1155 CFM/Ton Watts 131 187 247 308 373 Cooling 310 CFM 1085 1085 1 1085 1085 1085 CFM/Ton Watts 113 166 222 281 343 Cooling 290 CFM 1015 1015 1015 1015 1015 CFM/Ton Watts 96 146 199 256 315 Cooling 450 CFM 1800 1800 1800 1800 1714 CFM/Ton Watts 410 494 580 669 695 Cooling 420 CFM 1680 1680 1680 1680 1680 CFM/Ton Watts 342 420 1 502 585 671 Cooling 400 CFM 1600 1600 1600 1600 1600 CFM/Ton Watts 301 376 454 534 617 Cooling 370 CFM 1480 1480 1480 1480 1480 Cooling 4.0 Ton(a) CFM/Ton Watts 246 316 388 464 541 Cooling 350 CFM 1400 1400 1400 1400 1400 CFM/Ton(a) Watts 213 280 349 421 495 Cooling 330 CFM 1320 1320 1320 1320 1320 CFM/Ton Watts 183 247 313 381 1 452 Cooling 310 CFM 1240 1240 1240 1240 1240 CFM/Ton Watts 157 216 279 344 412 Cooling 290 CFM 1160 1160 1160 1160 1160 CFM/Ton Watts 133 189 248 310 375 (a) Factory Setting 12-1380-1 G-EN 23 Aticw"Siiwdvid HEATING & AIR CONDITIONING Heating and Cooling Airflow Tables Table 18. S9V2C10005PSBB Heating Airflow S9V2C10005PSBB Furnace Heating Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter 1st Stage Capacity=63,050 2nd Stage Capacity=97,000 Heating Airflow Target External Static Pressure Setting Airflow 0.1 0.3 0.5 0.7 0.9 CFM 1111 1097 1083 1068 1054 Low 1145 Temp.Rise 52 52 52 52 53 Watts 135 184 234 283 333 CFM 1393 1383 1372 1362 1352 Medium Low 1426 Temp.Rise 41 41 42 42 42 Heating 1st Watts 232 286 340 394 447 Stage CFM 1451 1447 1443 1438 1434 Medium(a) 1483 Temp.Rise 39 40 40 40 40 Watts 260 310 360 410 460 CFM 1495 1477 1458 1439 1421 High 1548 Temp.Rise 38 39 39 40 40 Watts 285 352 419 486 553 CFM 1564 1550 1536 1522 1508 Low 1590 Temp.Rise 58 58 58 58 59 Watts 323 397 470 544 618 CFM 1959 1936 1913 1891 1868 Medium Low 1980 Temp.Rise 46 46 47 47 47 Heating 2nd Watts 597 681 764 847 930 Stage CFM 2047 2034 2021 2008 1995 Medium(a) 2060 Temp.Rise 44 44 44 45 45 Watts 655 737 818 900 982 CFM 2102 2087 2073 2058 2044 High 2150 Temp.Rise 43 43 43 44 44 Watts 1 745 801 857 913 969 (a) Factory Setting. Table 19. S9V2C100D5PSBB Heating Airflow S9V2C100D5PSBB Furnace Heating Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter 1st Stage Capacity=63,050 2nd Stage Capacity=97,000 Heating Airflow Target External Static Pressure Setting Airflow 0.1 0.3 0.5 0.7 0.9 CFM 1093 1092 1090 1089 1088 Low 1094 Temp.Rise 53 53 53 52 52 Watts 126 183 240 296 353 CFM 1234 1238 1242 1247 1251 Medium Low 1296 Temp.Rise 47 47 47 47 47 Heating 1st Watts 186 243 299 356 413 Stage CFM 1279 1268 1256 1245 1234 Medium 1346 Temp.Rise 45 45 46 46 47 Watts 214 268 321 375 428 CFM 1453 1429 1405 1381 1358 High(a) 1512 Temp.Rise 40 40 41 41 42 Watts 277 344 411 478 545 CFM 1484 1477 1469 1461 1453 Low 1520 Temp.Rise 60 60 61 61 61 Watts 296 370 444 518 592 CFM 1693 1688 1684 1679 1674 Medium Low 1800 Temp.Rise 53 53 53 53 53 Heating 2nd Watts 449 533 618 702 786 Stage CFM 1768 1772 1775 1778 1781 Medium 1870 Temp.Rise 51 50 50 50 50 Watts 505 591 678 765 852 CFM 1969 1956 1944 1931 1918 High(a) 2100 Temp.Rise 1 45 45 46 46 46 Watts 1 723 789 854 920 986 (a) Factory Setting. 24 12-1380-1 G-E N Amm?Ao S*odfrd® HEATING & AIR CONDITIONING Heating and Cooling Airflow Tables Table 20. S9V2C10005PSBB/S9V2C100D5PSBB Cooling Airflow S9V2C10005PSBB/S9V2C100D5PSBB Furnace Cooling Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter Airflow External Static Pressure Cooling Unit Outdoor Setting 0.1 0.3 0.5 0.7 0.9 (CFM/ton) Cooling 450 CFM 1575 1575 1575 1575 1575 CFM/Ton Watts 263 333 406 481 558 Cooling 420 CFM 1470 1470 1470 1470 1470 CFM/Ton Watts 218 283 352 423 496 Cooling 400 CFM 1400 1400 1400 1400 1400 CFM/Ton Watts 191 254 319 388 458 Cooling 370 CFM 1295 1295 1295 1295 1295 CFM/Ton Watts 155 214 275 340 406 Cooling 3.5 Ton Cooling 350 CFM 1225 1225 1225 1225 1225 CFM/Ton Watts 134 190 249 311 375 Cooling 330 CFM 1155 1155 1155 1155 1155 CFM/Ton Watts 115 168 225 284 346 Cooling 310 CFM 1085 1085 1085 1085 1085 CFM/Ton Watts 98 148 202 259 319 Cooling 290 CFM 1015 1015 1015 1015 1015 CFM/Ton Watts 83 131 182 237 294 Cooling 450 CFM 1800 1800 1800 1800 1800 CFM/Ton Watts 381 460 542 627 713 Cooling 420 CFM 1680 1680 1680 1680 1680 CFM/Ton Watts 314 388 466 545 627 Cooling 400 CFM 1600 1600 1600 1600 1600 CFM/Ton Watts 275 345 419 496 574 Cooling 370 CFM 1480 1480 1480 1480 1480 CFM/Ton Watts 222 288 357 428 502 Cooling 4.0 Ton Cooling 350 CFM 1400 1400 1400 1400 1400 CFM/Ton Watts 191 254 319 388 458 Cooling 330 CFM 1320 1320 1320 1320 1320 CFM/Ton Watts 163 223 285 351 418 Cooling 310 CFM 1240 1240 1240 1240 1240 CFM/Ton Watts 139 195 254 317 381 Cooling 290 CFM 1160 1160 1160 1160 1160 CFM/Ton Watts 117 170 226 286 348 Cooling 450 CFM 2025 2025 2025 2025 2025 CFM/Ton Watts 531 620 711 805 901 Cooling 420 CFM 1890 1890 1890 1890 1890 CFM/Ton Watts 437 520 606 694 784 Cooling 400 CFM 1800 1800 1800 1800 1800 CFM/Ton Watts 381 460 542 627 713 Cooling 370 CFM 1665 1665 1665 1665 1665 CFM/Ton Watts 307 380 457 536 616 Cooling 4.5 Ton Cooling 350 CFM 1575 1575 1575 1575 1575 CFM/Ton Watts 263 333 406 481 558 Cooling 330 CFM 1485 1485 1485 1485 1485 CFM/Ton Watts 224 290 359 431 505 Cooling 310 CFM 1395 1395 1395 1395 1395 CFM/Ton Watts 189 252 317 386 456 Cooling 290 CFM 1305 1305 1305 1305 1305 CFM/Ton Watts 158 217 279 344 411 Cooling 450 CFM 2250 2250 2242 2137 2029 CFM/Ton Watts 717 816 909 908 905 Cooling 420 CFM 2100 2100 2100 2100 2029 CFM/Ton Watts 589 681 776 873 905 Cooling 400 CFM 2000 2000 2000 2000 2000 CFM/Ton Watts 512 600 691 784 878 Cooling 370 CFM 1850 1850 1850 1850 1850 Cooling 5.0 Ton(a) CFM/Ton Watts 411 492 577 663 752 Cooling 350 CFM 1750 1750 1750 1750 1750 CFM/Ton(a) Watts 352 429 509 592 676 Cooling 330 CFM 1650 1650 1650 1650 1650 CFM/Ton Watts 299 1 372 1 448 526 1 606 Cooling 310 CFM 1550 1550 1550 1550 1550 CFM/Ton Watts 252 320 392 467 543 Cooling 290 CFM 1450 1450 1450 1450 1450 CFM/Ton Watts 210 275 342 413 485 (a) Factory Setting 12-1380-1 G-EN 25 Aticw"Siiwdvid HEATING & AIR CONDITIONING Heating and Cooling Airflow Tables Table 21. S9V2D120U5PSBB Heating Airflow S9V2D120U5PSBB Furnace Heating Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter 1st Stage Capacity=75,660 2nd Stage Capacity= 116,400 Heating Airflow Target External Static Pressure Setting Airflow 0.1 0.3 0.5 0.7 0.9 CFM 1138 1158 1178 1198 1218 Low 1123 Temp.Rise 61 60 59 58 57 Watts 115 176 236 297 358 CFM 1371 1383 1394 1406 1417 Medium Low 1332 Temp.Rise 51 50 50 49 49 Heating 1st Watts 182 251 1 320 389 457 Stage CFM 1440 1450 1461 1471 1482 Medium(a) 1404 Temp.Rise 48 48 48 47 47 Watts 208 283 357 431 505 CFM 1669 1674 1680 1685 1691 High 1620 Temp.Rise 42 42 41 41 41 Watts 315 388 460 533 605 CFM 1654 1637 1621 1604 1587 Low 1560 Temp.Rise 65 66 67 67 68 Watts 291 360 430 499 568 CFM 1980 1951 1922 1893 1864 Medium Low 1850 Temp.Rise 55 56 57 58 58 Heating 2nd Watts 456 539 621 704 787 Stage CFM 2075 2037 1999 1961 1923 Medium(a) 1950 Temp.Rise 52 53 54 55 1 56 Watts 1 527 1 611 1 696 781 865 CFM 1 2280 2197 1 2114 2032 1 1949 High 2250 Temp.Rise 48 50 52 54 56 Watts 795 819 842 865 888 (a) Factory Setting. Table 22. S9V2D120D5PSBB Heating Airflow S9V2D120D5PSBB Furnace Heating Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter ist Stage Capacity=75,660 2nd Stage Capacity= 116,400 Heating Airflow Target External Static Pressure Setting Airflow 0.1 0.3 0.5 0.7 0.9 CFM 1234 1240 1246 1252 1258 Low 1160 Temp.Rise 56 56 56 55 55 Watts 137 198 258 319 380 CFM 1305 1311 1318 1325 1332 Medium Low 1332 Temp.Rise 53 53 53 52 52 Heating 1st Watts 158 221 284 347 410 Stage CFM 1324 1510 1697 1884 2070 Medium 1404 Temp.Rise 53 46 39 32 25 Watts 179 246 313 380 447 CFM 1598 1484 1371 1257 1144 High(a) 1620 Temp.Rise 44 47 49 52 54 Watts 266 316 366 416 466 CFM 1687 1673 1659 1645 1631 Low 1750 Temp.Rise 63 64 64 65 65 Watts 327 407 487 568 648 CFM 1788 1771 1754 1738 1721 Medium Low 1850 Temp.Rise 60 60 61 61 62 Heating 2nd Watts 380 464 549 633 718 Stage CFM 1891 1862 1833 1803 1774 Medium 1950 Temp.Rise 56 57 58 60 61 Watts 424 524 624 724 824 CFM 2080 2100 2120 2140 2160 High(a) 2250 Temp.Rise 51 51 51 51 51 Watts 708 768 828 888 948 (a) Factory Setting. 26 12-1380-1 G-E N Amm?Ao S*odfrd® HEATING & AIR CONDITIONING Heating and Cooling Airflow Tables Table 23. S9V2D120U5PSBB/S9V2D120D5PSBB Cooling Airflow S9V2D120U5PSBB/S9V2D120D5PSBB Furnace Cooling Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter Airflow External Static Pressure Cooling Unit Outdoor Setting 0.1 0.3 0.5 0.7 0.9 (CFM/ton) Cooling 450 CFM 1575 1575 1575 1575 1575 CFM/Ton Watts 248 316 387 461 537 Cooling 420 CFM 1470 1470 1470 1470 1470 CFM/Ton Watts 206 270 337 407 479 Cooling 400 CFM 1400 1400 1400 1400 1400 CFM/Ton Watts 181 1 243 307 374 443 Cooling 370 CFM 1295 1295 1295 1295 1295 CFM/Ton Watts 148 205 265 328 393 Cooling 3.5 Ton Cooling 350 CFM 1225 1225 1225 1225 1225 CFM/Ton Watts 128 182 240 300 363 Cooling 330 CFM 1155 1155 1155 1155 1155 CFM/Ton Watts 111 162 217 274 335 Cooling 310 CFM 1085 1085 1085 1085 1085 CFM/Ton Watts 95 143 195 250 309 Cooling 290 CFM 1015 1015 1015 1015 1015 CFM/Ton Watts 80 126 176 228 285 Cooling 450 CFM 1800 1800 1800 1800 1800 CFM/Ton Watts 356 433 514 597 682 Cooling 420 CFM 1680 1680 1680 1680 1680 CFM/Ton Watts 295 368 443 521 601 Cooling 400 CFM 1600 1600 1600 1600 1600 CFM/Ton Watts 258 328 400 475 552 Cooling 370 CFM 1480 1480 1480 1480 1480 CFM/Ton Watts 210 274 342 412 484 Cooling 4.0 Ton Cooling 350 CFM 1400 1400 1400 1400 1400 CFM/Ton Watts 181 243 1 307 374 443 Cooling 330 CFM 1320 1320 1320 1320 1320 CFM/Ton Watts 155 213 274 338 405 Cooling 310 CFM 1240 1240 1240 1240 1240 CFM/Ton Watts 132 187 245 306 369 Cooling 290 CFM 1160 1160 1160 1160 1160 CFM/Ton Watts 112 163 218 1 276 337 Cooling 450 CFM 2025 2025 2025 2025 2025 CFM/Ton Watts 492 579 669 761 855 Cooling 420 CFM 1890 1890 1890 1890 1890 CFM/Ton Watts 406 488 572 659 747 Cooling 400 CFM 1800 1800 1800 1800 1800 CFM/Ton Watts 356 433 514 597 682 Cooling 370 CFM 1665 1665 1665 1665 1665 CFM/Ton Watts 288 360 435 512 592 Cooling 4.5 Ton Cooling 350 CFM 1575 1575 1575 1575 1575 CFM/Ton Watts 248 316 387 461 537 Cooling 330 CFM 1485 1485 1485 1485 1485 CFM/Ton Watts 212 277 344 414 487 Cooling 310 CFM 1395 1395 1395 1395 1395 CFM/Ton Watts 180 241 305 371 440 Cooling 290 CFM 1305 1305 1305 1305 1305 CFM/Ton Watts 151 208 269 332 398 Cooling 450 CFM 2250 2250 2250 2188 2103 CFM/Ton Watts 659 756 856 900 922 Cooling 420 CFM 2100 2100 2100 2100 2100 CFM/Ton Watts 544 634 728 823 920 Cooling 400 CFM 2000 2000 2000 2000 2000 CFM/Ton Watts 475 561 650 741 834 Cooling 370 CFM 1850 1850 1850 1850 1850 Cooling 5.0 Ton(a) CFM/Ton Watts 383 463 546 631 717 Cooling 350 CFM 1750 1750 1750 1750 1750 CFM/Ton(a) Watts 329 405 484 564 647 Cooling 330 CFM 1650 1650 1650 1650 1650 CFM/Ton Watts 281 352 427 503 1 582 Cooling 310 CFM 1550 1550 1550 1550 1550 CFM/Ton Watts 237 305 375 448 523 Cooling 290 CFM 1450 1450 1450 1450 1450 CFM/Ton Watts 199 262 328 397 468 (a) Factory Setting 12-1380-1 G-EN 27 ,��cler�rca� s��d HEATING & AIR CONDITIONING Maximum Vent Length Table Model Maximum Total Equivalent Length in Feet for Vent and Inlet Air(See Notes) 2 inch or 2.5 inch Pipe 3 inch or inch Pipe Altitude 0-2,000 Feet S9V2B040U3PS,S9V2B040D3PS,S9V2B060U3PS, 200 200 S9V2B060D3PS,S9V2B060U4P5 S9V2B080U4PS,S9V2B080D4PS,S9V2C080U5PS 100 200 S9V2C10004PS,S9V2C100D4PS,S9V2C10005PS, S9V2C100D5PS 50 200 S9V2D120U5PS,S9V2D120D5PS Note 200 Altitude 2,001-5,400 Feet S9V2B040U3PS,S9V2B040D3PS,S9V2B060U3PS, 200 200 S9V2B060D3PS,S9V2B060U4PS S9V2B080U4PS,S9V2B080D4PS,S9V2C080U5PS 80 120 S9V2C10004PS,S9V2C100D4PS,S9V2C10005PS, 50 150 S9V2C100D5PS S9V2D120U5PS,S9V2D120D5PS Note 200 Altitude 5,401-7,800 Feet S9V2B040U3PS,S9V2B040D3PS,S9V2B060U3PS, 100 150 S9V2B060D3PS,S9V2B060U4PS S9V2B080U4PS,S9V2B080D4PS,S9V2C080U5PS 50 70 S9V2C10004PS,S9V2C100D4PS,S9V2C10005PS, S9V2C100D5PS Note 1 100 S9V2D120U5PS,S9V2D120D5PS Note 100 Altitude 7,801-10,100 Feet S9V2B040U3PS,S9V2B040D3PS,S9V2B060U3PS, 50 90 S9V2B060D3PS,S9V2B060U4PS S9V2B080U4PS,S9V2B080D4PS,S9V2C080U5PS Note 50 S9V2C10004PS,S9V2C100D4PS,S9V2C10005PS, Note 1 50 S9V2C100D5PS S9V2D120U5PS,S9V2D120D5PS Note 50 Notes: 1. Not allowed 2. For PolyProp by Duravent,Z-DENS by Novaflex Group,InnoFluepby Centrotherm,and Polyflue•"manufactured modular venting systems that are in the approved vent pipe material table,fitting equivalent vent lengths may be different from what is shown in Note 6.Refer to the venting system manufacturer's installation instruction for appropriate venting diameters and equivalent lengths. 3. Minimum vent length for all models: 15'equivalent. 4. DO NOT MIX PIPE DIAMETERS IN THE SAME LENGTH OF PIPE OUTSIDE THE FURNACE CABINET(Except adapters at the top of the furnace). If different inlet and vent pipe sizes are used,the vent pipe must adhere to the maximum length limit shown in the table above(See note 7 below for exception).The inlet pipe can be of a larger diameter,but never smaller than the vent pipe. 5. MAXIMUM PIPE LENGTHS MUST NOT BE EXCEEDED!THE LENGTH SHOWN IS NOTA COMBINED TOTAL,IT IS THE MAXIMUM LENGTH OF EACH(Vent or Inlet air pipes). 6. One SHORTradius 900 elbow is equivalent to 10'of 4"pipe,10'of 3"pipe,or 8'of 2"pipe.One LONG radius elbow is equivalent to 6'of 4" pipe,7'of 3"pipe,or 5'of 2"pipe.Two 450 elbows equal one 900 LONG elbow.One MITERED elbow is equivalent to 12'of 3"pipe or 12'of 2"pipe. 7. The termination tee or bend must be included in the total number of elbows.If the BAYAIR30AVENTA or BAYAIR30CNVENT termination kit is used,the equivalent length of pipe is 5 feet.For BAYVENT200B and BAYVENTCN200B the equivalent length is 0 feet. 8. For Canadian applications,venting systems must meet ULC-S636 requirements. 9. The INLETAIR of one pipe systems require the installation of a minimum of one 900 elbow(to prevent dust and debris from falling straight into the furnace). 28 12-1380-1 G-E N ,��ce�rca� �S�iaara! HEATING & AIR CONDITIONING S9V2 Wiring Diagram TO BURNER BOX HARN YU47 1 1 YU48 FLAME_R_OLLOUTI YL146 2 2 YU49 YU50 YU48 INDUCER LIMIT CONDENSATE L— r r——-1 _RAF-1 FLAM_E_ROLLOUT2 PR154 YU52 r I —I YU45 YU50 YU51� L —J L-- i I SEE NOTE THERMA_L_LIMIT _RAF-2 11 YU49 -1 YU51 PS2 GAS I P51 I , YU45 L— I r , VALVE r--, i i —I 1L iJPR 12V 1 YU42 2 gA Tx 2 L-- I TO 1 2 GR141 3 BLOWER Rx 3 _ POWER 1 2 q MOTOR GND 4 HARNESS /42'SEE NOTE 12 ry, 5 rm a s �mm a i o >"> BL135 WH137 WH136 BK/38 120v 60 Hz.1 PH S e? "">;M aO POWER SUPPLY PER LOCAL CODE >>3 m m 3 3 m IFC IS POLARITY SENSITIVE_TT�� JUNCTION BOX � IH •N 1 2 3 4 5 6 7 6 9 1011 12 BLl2 �S WH/15 1 2 3 4 5 6 7 8 9 10 11 12 _ I GND I I I zap 1zo� RDI6 __J BK114 SEE NOTE 10 3> m LINE CHOKE BK128 11 JI BK130 2 2 BK113 1 BK129 PANELLOOP BKi27 EAC HUM LINE` NEUTRAL GR%YL 1 BK 18 1 VENT 241120 VAC 3 2 1 4 3 2 1 RD19 2 MOTOR MAY BE USED n 255 z o WH2O� 3 (INDUCER) m m x SEE NOTE 8 IGN IGN-N 5 WH121 BKJ 21 12 FP IND-N 4 WHI20 BK/22 2 BR153 11 HLI IND-LO 3 RD119 BR/10 10 MVH IND-HI 2 BK118 BK BLACK OR ORANGE BR BROWN RDl9 9 MVL ® IGN-H 1 BK122 WH WHITE PR PURPLE RD RED 8 GND YL YELLOW GR GREEN BL BLUE BR17 7 PS2 ®® Tx 4 WH12 RDI6 6 TH GND 3 BK123 INTEGRATED FURNACE CONTROL BUS 5 MVC Rx 2 WH12q ELECTRICAL RATING pwq q HLO 12V 1 BL126 INPUT:24 VAC,60 HZ. XFMR SEC.CURRENT:450 MA. OR111 3 P5 1 H LINE +MV LOAD BU2 2 TR Tx TRANSMITSIGNAL MVOUTPUT 1.6A 24VAC N NEUTRAL RX RECEIVE SIGNAL IND OUTPUT:2.2 F ,3.5 LRA @ pR11 1 ILI GND GROUND TH 24VAC(HOT) 120 VAC MAX. HLO HIGH LIMIT OUTPUT TR 24VAC(COMMON) IGN OUTPUT:2.OA@120 VAC z HLI HIGH LIMIT INPUT CIRC.BLOWER OUTPUT:14.5 TO PERSONALITY MODULE MVC VALVE COMMON PSi 1ST STAGE FIDIF LRA 120 VAC m MVL VALVE LOW STAGE x 3 PRESSURE INPUT HUMIDIFIER&AIR CLEANER m co MVH VALVE HIGH STAGE FLAME PS2 2ND STAGE TNS TRANSFORMER (DRY CONTACTS) gym++ i--[=3-0--WH112 �+ PRESSURE INPUT ILI INDUCER LIMIT INPUT MAX.LOAD:1.0A @ 120 VAC FIC J I I I I , IND INDUCER IGN IGNITER 24 VAC OR 120 VAC MAY BE m— IFC INTEGRATED FP FLAME PROBE USED SEE NOTE 6 BK wz wt N c Btc vz vt o FURNACE CONTROL HI SECOND STAGE FUSE:5A "INTERNAL THERMAL PROTECTION TRERMosTAT RAF REVERSE AIR FLOW LO FIRST STAGE TIMINGS BK JUMPER SEE NOTES 2,3,4,5,6 PREPURGE:0 SEC. CONDENSATE o PS PRESSURE INTERPURGE:60 SEC. 5 Ii FRS FLAME ROLLOUT o�ti,o FUSE SWITCH SWITCH POST PURGE: SEC. IGN WARMUP:20 SEC. SWITCH IAP:2;TFI:5 SEC. LINE FACTORY RETRIES:2 RECYCLES:10 FP FLAME PROBE 6-6 LC LINE CHOKE RAF REVERSE 24V WIRING HEAT ON DELAY:UP T030 SEC. AIR FLOW 1 COOL ON DELAY:0 SEC. IGN HOT SURFACE - —LINE l FIELD AUTO RESTART:60 MIN, IGNITER T GROUND BK JUMPER 24V f WIRING AUTO RESTART PURGE:60 SEC. 12-1380-1 G-EN 29 Amwe "S7iwdad HEATING & AIR CONDITIONING S9V2 Wiring Diagram NOTES: 1. IF ANY OF THE ORIGINAL WIRING AS SUPPLIED WITH THIS FURNACE MUST BE REPLACED,IT MUST BE WITH WIRE HAVING A TEMPERATURE RATING OF AT LEAST 105°C. WIRES 12,48,49,50,AND 51 REQUIRE A TEMPERATURE RATING OF AT LEAST 250°C. 2. FOR PROPER AIRFLOW IN COOLINGMEAT PUMP MODE,"Y1"MUST BE CONNECTED TO THE THERMOSTAT FOR SINGLE STAGE UNITS. FOR TWO STAGE UNITS,"Y1"AND"Y2"MUST BE CONNECTED TO THE THERMOSTAT. VSPD OD SYSTEMS REQUIRE DIFFERENT CONNECTIONS,SEE RELAY PANEL INSTRUCTIONS. 3. FOR SINGLE STAGE THERMOSTATS,JUMPER"W1"AND"W2"TERMINALS. SECOND STAGE HEATING WILL BE ENERGIZED ONCE THE INTER-STAGE DELAY HAS EXPIRED. "HT2"WILL BE SHOWN ON SEVEN SEGMENT DISPLAY AT ALL TIMES. 4. FOR HEAT PUMP SYSTEMS,"Y1"AND"0"TERMINALS MUST BE CONNECTED TO THE ROOM THERMOSTAT. FOR TWO STAGE UNITS,"Y1","Y2",AND"0"TERMINALS MUST ALL BE CONNECTED TO THE ROOM THERMOSTAT. 5. FOR TWO STAGE SYSTEMS,USE"Y1"FOR LOW SPEED AND"Y2"FOR HIGH SPEED CONNECTION TO THE LOW-VOLTAGE TERMINAL BLOCK. SINGLE STAGE SYSTEMS USE"Y1"FOR THE CONNECTION TO THE LOW-VOLTAGE TERMINAL BLOCK. 6. THE"BK"JUMPER MUST BE CUT WHEN APPLYING AN AIRFLOW COMMAND TO THE'BK"TERMINAL SUCH AS PULSE WIDTH MODULATION. 7. SEE INDOOR MOTOR AIRFLOW SELECTION CHART,LOCATED IN THE INTEGRATED FURNACE CONTROL MENU&OPTIONS SETTINGS TO SETAIRFLOW AND COOLING OFF DELAYS. 8. FLAME SENSE TEST PADS:1 VDC=1 MICROAMP FLAME CURRENT CAN VARY DEPENDING ON THE VOM THAT S9V2 IS USED AND THE VOLTAGE SUPPLIED TO THE FURNACE.THE ACCEPTABLE RANGE IS 0.75-3 MICROAMPS. 9. CORRECT PERSONALITY MODULE IS REQUIRED FOR PROPER FURNACE OPERATION. PERSONALITY MODULE IS SPECIFIC TO EACH MODEL&SERIAL NUMBER,AND IS TO REMAIN WITHIN ITS ORIGINAL UNIT. 10.LINE CHOKE AND WIRE BK/28 ONLY USED ON MODELS WITH 3/4 AND 1 HP MOTORS. 11.DOWNFLOW MODELS ONLY USE ONE REVERSE AIRFLOW SWITCH. 12.CONNECTION MAY OR MAY NOT BE PRESENT. IF CONNECTION IS NOT PRESENT,WIRES 33 AND 34 WILL NOT BE USED. 2 Stage Inducer with ECM Blower Motor E04 Open Thermal Limit,Rollout Switch,or Reverse Airflow Switch MbiriPMOf-T- OdU I Outdoor Unit E05 Flame detected should not be present Id, Idle [OF Blower Constant Fan Airflow Multiplier%E6_I Voltage reversed polarity Hk 1 1st Stage Heating CPC Cooling CFM/Ton E6_2 Bad Grounding HL2 2nd Stage Heating CPH Heat PUTID Heating CFM/Ton ES_3 1 Igniter elay fails, 2 Igniter open R,F Airflow(followed by Hod Heat Off Delay sec El_I 1st stage gas valve MVL is energized when it should be off Airflow x 10 1 5d Inter-Stage Delay sec EOB Flame current is low,but still stron g enough to allow operation. [OF Continuous Fan 9HC Gas Heating CFM Airflow x10 E09 Open Inducer Limit Switch or Condensate Switch CL 11 st Sta a Coolin rLIn Run Test Mode IE I 1 (1)1st stage gas valve not energized when it should be CL2 Error Codes (2)1st stage gas valve relay stuck closed HP 1 1st Stage Heat Pump Ell I Loss of the IRQ/other internal failures (3)2nd stage gas valve relay stuck closed HP2 2nd Stage Heat Pump E2_I Retry exceeded Failed to est flame (4)2nd stage gas valve energized when it should not be dFt Defrost Mode E2_2 Recycles exceeded(loss of established 5 2nd stage gas valve not energized when it should be • flame or 1OX PS1 open E 12 Open fuse Err Active Alarm Menu E2_3 1 st Stage Gas Valve not energized when E 13 Blower HP/OEM ID L6 F Last 6 Faults(To Clear, it should be exceeded after 10 times E 14 No PM and local copy bad ❑ r Hold Option Button 5 sec) E3_I Shorted Pressure Switch 1st Stage E 15 Both Unit Data File in PM and local Unit Cr Code Release Number E3_2 Open Pressure Switch 1st Stage Data File are Corrupt COdI Coolinq Off Dela sec E3_3 I Shorted Pressure Switch 2nd Stage E 11 Blower motor no communication response Outdoor Tonnage I E3_4 I Open Pressure Switch 2nd Stage E IB Blower communication failure on the control ••D3a6o22Po1 30 12-1380-1 G-E N 79 eao S*odrrd® HEATING & AIR CONDITIONING S9V2 Wiring Diagram 120v 60 Hz.1 PH POWER SUPPLY PER LOCAL CODE _ �JIINCTION BOX GTH ]N ^n"^ OND II I I JyVL L T 0 LjPANELLOOP BK _ PC -- uNE+ 3 BK CACaf 2 I BK SEE NOTE 1D x x 1 I BK 1JA TWA Q WH YL 21. CIRCA 3 WH II GR WH cuo I I ' uxEu 1 WH BK II �xH 1 BK 1 VENT ixo*I 2 BK p MOTOR I woo RD 3 INDUCER) 3 IIOx 4 WH tGND �cuu 5 WH WH IGN BK I m 1 BL BL w 2 WH WHGND 3 BK WH WH BK I I ui 1 I PR TNS m 2 BL BK Psi 3 OR 24v 120v Psi 4 I PR rrvC 5 BI __ WH w 6 [RD BURNER vs: 7 BR �I BOX GND xo 6 GR srv0 9 RD RD 1 I I wi 10 BR BL 2 c> RI BR BR 3 ry 12 WH I I I I BR _ PS2 YL �SR BK W2 W7 R G BC Y2 ri 0 THERMOSTAT SEE NOTES 2,3,4,5,6 FLAME_ROLLOUT2 THERMAL LIMIT YL r YL *SEE NOTE RAF-2 11 RAF-1 YL n0 YLL _ L _ CONDENSATE INDUCER LIMIT r - - � I_ � } PR PR r IL _ _ J L _ I PR FLAME_ROLLOUTI PS1 YL OR YL 12-1380-1 G-EN 31 HEATING & AIR CONDITIONING Electrical Connections Make wiring connections to the unit as indicated on enclosed wiring diagram.As with all gas appliances using electrical power,this furnace shall be connected into a permanently live electric circuit.It is recommended that furnace be provided with a separate"circuit protection device" electric circuit.The furnace must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code,ANSI/NFPA 70 or CSA C22.1 Electrical Code,if an external electrical source is utilized.The integrated furnace control is polarity sensitive.The hot leg of the 120V power supply must be connected to the black power lead as indicated on the wiring diagram. Refer to the SERVICE FACTS literature and unit wiring diagram attached to furnace. Field Wiring Two stage Thermostat Furnace FIELD WIRING DIAGRAM FOR TWO STAGE HEATING THERMOSTAT,TWO STAGE COOLING BK -- ----- -- BK NOTES: 1) For PWM(BK)enabled thermostats,cut the BK jumper W2 W2 on the IFC and connect wiring. Outdoor Unit 2) The factory Y1-O jumper must remain in place for proper W1 - ----- - W1 (No Transformer) LED read out in cooling mode. 4 3) Y1 and Y2 wiring from the thermostat must connect to __ _____ __® �B/C the IFC for proper airflow and LED readout. _, 4) Single compressor and two compressor airflow is auto- s © matically set with the IFC Menu optionsin ODU section. L`?f 2-1=2 stage/1 compressor(1st stage airflow=80%) Y2 2-2=2 stage/2 compressors(1st stage airflow=50%) BIC -- ----- -- BIC -- - Furnace IFC Y2 Y2 �y 1 ®Cd®�®® O 39 Y1 Y1 E3 INTER-COMPONENT WIRING ST 0 1 K W2 W1 R G B/CY2 Yt 7 O SEE 24 V FIELD WIRING NOTE 2 BK JUMPER 24 V FACTORY WIRING SEE NOTE 1 Two Stage Thermostat Furnace FIELD WIRING DIAGRAM FOR TWO STAGE HEATING THERMOSTAT,TWO STAGE HEAT PUMP BK -- ----- -- BK NOTES: Outdoor Unit 1) For PWM(BK)enabled thermostats, cut the BK jumper W2 -- ----- -- W2 (No Transformer) on the IFC and connect wiring. 2) Remove the factory Y1-0 jumper for HP systems W1 - ----- -- W1 -- ---- -- X2 for proper LED read out. 3) Y1 and Y2 wiring from the thermostat must connect to Y1 and R Y2 of the IFC for proper airflow and LED readout. Q 4) Single compressor and two compressor airflow is automatically ........ _ -- --- _B/C set with the IFC Menu options in ODU section. © 2-1=2 stage/1 compressor(1st stage airflow=80%) 2-2=2 stage/2 compressors(1 st stage airflow=50%) BIC - BIC Y2 Furnace IFC - o - 1 Y2 - Y2 Y1 ®0 RE =nu E3 Y1 - ----- -- Y1 ------------ SEE sra� BK W2 W1 R G B/C Y2 Y1 NOTE 2 O�- ----- O� ---- O INTER-COMPONENT WIRING R-BK JUMPER 24 V FIELD WIRING SEE NOTE 1 24 V FACTORY WIRING 32 12-1380-1 G-E N Awlkeai S-laffdard. HEATING & AIR CONDITIONING Electrical Connections Single s Thermosttatat Furnace FIELD WIRING DIAGRAM FOR Therm SINGLE STAGE HEATING THERMOSTAT, SINGLE STAGE COOLING NOTES: 1) For PWM (BK)enabled thermostats, cut the BK jumper SEE W2 - on the IFC and connect wiring. NOTE 4 2) The factory Y1-0 jumper must remain in place for proper LED read out in cooling mode. 3) Y1 wiring from the thermostat must connect to Y1 of the IFC for proper airflow and LED readout. Outdoor Unit 4) Place field supplied jumper between W1 and W2 on the (No Transformer) IFC. Interstage delay is factory set for 10 minutes but is field -- ----- - adjustable with the Menu option in the ISD section. 5) Single stage airflow is set with the IFC Menu options BBC in ODU section. Select 1-1. Y2 Furnace IFC Y1 ®®® ® A = 0 Y1 - ® o0000 � a ��Q 440 E3 INTER-COMPONENT WIRING BK JU LJ Mo BK W2 W1 R G B/C Y Yl 0 SEE --------- 24 V FIELD WIRING NOTE 2 24 V FACTORY WIRING BKJUMPER SEE NOTE 1 Single Stage Thermostat Furnace FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING THERMOSTAT, SINGLE STAGE HEAT PUMP BK - ----- -- BK NOTES: SEE Outdoor Unit 1) For PWM (BK)enabled thermostats, cut the BK jumper NOTE 4 (No Transformer) W2 - on the IFC and connect wiring. Q 2) Remove the factory Y1-O jumper for HP systems �X2 for proper LED read out. 3) Y1 wiring from the thermostat must connect to Y1 of R the IFC for proper airflow and LED readout. 4) Place field supplied jumper between W1 and W2 on the IFC. Interstage delay is factory set for 10 minutes but is field �- ----- --© adjustable with the Menu option in the ISD section. 5) Single stage airflow is set with the IFC Menu options BIC - ---- -- BIC - ---- ---' BIC in ODU section. Select 1-1. Furnace IFC Y2 A V 3 �4 44� E3 SEE '"' X J EK NOTE 2 sT, BK W2 Wl R G B/C Y2 Y1 0 INTER-COMPONENT WIRING BKJUMPER 24 V FIELD WIRING SEE NOTE 1 24 V FACTORY WIRING 12-1380-1 G-EN 33 i eao S-lavdard® HEATING & AIR CONDITIONING Electrical Connections COMMUNICATING CONTROLS WITH NON-COMMUNICATING S9V2 FURNACE AND COMMUNICATING VS COOLING/HP Relay Panel Communicating Control D R B -------------- ---------, Outdoor Unit Indoor Unit 000----- -- I ® I E------- - - -- ---I ©-----------BIC - -' Fo SOV ❑� Y1 STG1 NOTES: Y1 Y2 STG2 1 be off orCut theBcyc dpon off oner at thelforothe IFC oftwo k propndor unit-Aer cutting ehiyjumper,power must 2. Requires an 850 control with software version 3.0+or 1050.Not a valid YZ ----- W 1 STG 1 combination with 950 control CPC=CFM/Ton cooling. Must be set to 400. W1 - -- -W2 STG2 CPH=CFM/Ton heating. Must be set to 400. WZ - W3 STG3 Furnace LED's will read"L oF"continous fan during cooling and heat ---- pump operation. I I - - ----1 a 1 FAN BK --------- BK PWM HUM 0 , HUM HUM E-< < HUM 24 V Field Wiring AUX1 z° AUX1 AUX1 AUX1 AUX2 o A AUX2 AUX2 AUX2 34 12-1380-1 G-E N ,��ce�rca� �S�iaara! HEATING & AIR CONDITIONING Outline Drawings o NLn ❑-O 12-1380-1 G-EN 35 Amwe "S7iwdv-d, HEATING & AIR CONDITIONING Outline Drawings _ m aF_ i N w I I � a Q� — (B aJ c i > U O N Q V) T- Z - - w I j tc - °3 36 12-1380-1 G-E N ,4*weao S*odsrd HEATING & AIR CONDITIONING Outline Drawings SEW!Ji 2 J- U_ = =ram a V a--+ " LL O N Q O O o flc 0 0 --- ------------- - �� --T- an 12-1380-1 G-EN 37 Amwe "S7iwdv-d, HEATING & AIR CONDITIONING Outline Drawings v a• � d W - V ' (B =5 N LLL c U m Q AE I = 1 � e �_- - - - - - - - - _ - I I I � I I I I - I 38 12-1380-1 G-E N ,4*weao S*odsrd HEATING & AIR CONDITIONING Outline Drawings as a• v ra 4� U- c V m � v N O N V LE) (B❑MIn N �o T - - T-. :---T T-T i W ;!�< 2 ;�-< 12-1380-1 G-EN 39 Amwe "S7iwdv-d, HEATING & AIR CONDITIONING Outline Drawings v n ° V ' (� 4- - i N LLL O � V � N O Ln 0 0 O O 0 0 w I I I I r - _- - 40 12-1380-1 G-E N Notes 12-1380-1 G-EN 41 Notes 42 12-1380-1 G-E N Notes 12-1380-1 G-EN 43 44&6fi6" Sia"dwd® HEATING & AIR CONDITIONING About American Standard Heating and Air Conditioning American Standard has been creating comfortable and affordable living environments for more than a century. For more information, please visit www.americanstandardair.com. M D Eta �S Intertek The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices. 12-1380-1G-EN 15May2o2o Supersedes 12-1380-1 F-EN (August 2019) ©2020 American Standard Heating and Air Conditioning Permit#: 6686 Permit Date: 08/26/25 Permit Type: RESIDENTIAL MECHANICAL Project Nam e OUEDRAOGO MECH PERMIT Applicant Nam a CM HEATING Applicant Address: 1500 INDUSTRY ST#200 Applicant, City, State, Zip: EVERETT Contact: SABRINA KENNARD Phone: 4252590550 Em al: PERMITS@CMBEATING.COM Scope of Work: GAS FURNACE SWAP Valuation: 10985.00 Square Feet: 2620 Num ber of Stories: 2 Construction Type: VB O xupancy G ioup: R-3; Residential ID Code: Permit Issued: 08/27/2025 Permit Expires: 02/26/2026 Form Permit Type: RESIDENTIAL MECHANICAL Status: COMPLETE Assigned To: Hannah Hardwick Property Parcel# A ddress L egal Description 0 wner Nam e &ner Phone Z oning 01089200003100 8 323 172ND PL NE CORNERSTONE HOMES 910 UNDEVELOPED NW LLC (VACANT)LAND Contractors Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License# CM HEATING INC 4 25-259-0550 1500 INDUSTRY ST STE CONSTRUCTION Plum ling Contractor CMHEAHL750LP 200 CONTRACTOR CM HEATING INC 4 25-259-0550 1500 INDUSTRY ST STE CONSTRUCTION Construction Contractor CMHEAHL751W 200 CONTRACTOR CM HEATING INC 4 25-259-0550 1500 INDUSTRY ST STE CONSTRUCTION U13I 605890285 200 CONTRACTOR Inspections Date Inspection Type D escription S cheduled Date C om lieted Date I nspector Status 01/12/2026 R00.FURNACE FINAL w ould like it at 10:30 if possibe 0 1/16/2026 0 1/16/2026 B UILDING Corn lieted Fees Fee D escription N otes A m aunt Processing/Technology $25.00 Inspection $75.00 Forced Air Heat<100 BTU/h E nter#of units $15.00 Mechanical Base Perm i Fee $25.00 Credit Card Service $4.20 Total $144.20 Attached Letters Date L etter D escription 08/26/2025 Building Perm i 08/26/2025 Web Form-Residential Mechanical Application Paym arts Date P aid By D escription P aym ait Type A ccepted By A m aunt 08/26/2025 M att Zivanov $4.20 08/26/2025 XBP Conf:241313511 $140.00 O astanding Balance $ 0.00 Notes Date N ote C reated By: 12/29/2025 s ent expiration notice Hannah Hardwick Uploaded Files Date File Nam e 08/27/2025 28024279-2025 BLD6686 Issued Perm t.pdf 08/27/2025 28024237-2025 BLD6686 Issued Permt.pdf 08/26/2025 4eOb422173d45041febc751571c8b4ed ouedraogo aapp.pdf 08/26/2025 65e177fa6aOcb43d5bb12e337746af134 s9v2-bb specs.pdf