Loading...
HomeMy WebLinkAbout17727 W COUNTRY CLUB DR_BLD1208_2026 RESIDENTIAL MECHANICAL PERMIT APPLICATION t�N Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Add ress: 17727 WCOUNTRYCLUB DR Project Description:IN STALL HP AND GF Owner: LAMES DUFFEY Address. 17727 WCOUNTRYCLUB DR City. ARLINGTON State.WA Zip Code: 98223 Phone. 425-330-1913 Email:eaguarllc@jlduffey.org Applicant: CM HEATING Address: 1415 BROADWAY City. EVERETT State.WA Zip Code: 98201 Phone. 4252590550 Email: MEREDITH@CMHEATING.COM CONTRACTOR INFORMATION Contractor Name:CM HEALING Address: 1415 BROADWAY City. EVERETT State.WA Zip Code: 98201 License Number:CMHEAMH877DN Expiration. 5/2017 Phone: 4252590550 Email:MEREDITH@CMHEATING.COM STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 Y. RESIDENTIAL MECHANICAL PERMIT APPLICATION SING Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model # AFUE80 Heat Pump Model #4A6V8048A1000A AFUE80 HSPE9'6 ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: [El Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: Date: 11/07/2016 Applicant Printed Name: MEREDITH GILBERT I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 Amw" s7izoda-d. HEATING & AIR CONDITIONING Specif ication Variable Speed Accul-ink" Heat Pump 4A6V8048A 1000A TAG: t SAFETY WAR Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air- conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. September 2013 4A6V8048A-SPEC-1 ��Ingersoll Rand AmweaRS7�W45(4vdo HEATING & AIR CONDITIONING LIQUID LINE SERVICE VALVE,"E"I.E.FEMALE BRAZED CONNECTION WITH 1/4"SAE FLARE B PRESSURE TAP FITTING. C H F GAS LINE SERVICE VALVE,"D"I.D.FEMALE FIG.2 BRAZED CONNECTION ELECTRICALAND REFRIGERANT WITH 1/4"SAE FLARE COMPONENT CLEARANCES PRESSURETAP FITTING. PER PREVAILING CODES. J SERVICE PANEL-� G TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524(5 FEET) ABOVE UNIT.UNIT SHOULD BE PLACED SO ROOF RUN-OFFWATER DOES NOT POUR DIRECTLY ON UNIT,AND SHOULD BE AT LEAST 305112")FROM WALL AND ALL SURROUNDING SHRUBBERY ONTWO SIDES.OTHER GAS LINE SERVICEVALVE, TWO SIDES UNRESTRICTED "D"I.DE BRAZED CONNECTION WITHH 1/4"1/4"SA FLARE PRESSURE TAP FITTING. G -. K ELECTRICAL SERVICE PANEL F 250) H A 22.2(7/8)DIA.HOLE LOW VOLTAGE LIQUID LINE SERVICE FIG.3 28.60-1/8)DIA.K.O. VALVE,"E"I.D.FEMALE WITH 22.217/81 DIA. BRAZED CONNECTION HOLE IN CONTROL Box WITH 1/4"SAE FLARE BOTTOM FOR ELECTRICAL PRESSURE TAP FITTING.J POWER SUPPLY LIQUID LINE SERVICE VALVE,I.D.FEMALE H �E^ F BRAZE CONNECTION WITH 1/4"SAE FLARE PRESSURETAP FITTINGS J K.O.FOR ALTERNATE ELECTRICAL ROUTING FIG,.'I G GAS LINE 114TURN BALL SERVICEVALVE, 'pA I.D.FEMALE BRAZED CONNECTION WITH 1/4 SAE FLARE PRESSURETAP FITTING. Model Base A B C D E F G H J K 4A6V8048A 4 1045 946 870 22-7/8 10-3/8 127 76 197 57 813 (41-1/8) (37-1/4) (34-1/4) (5) (3) (7-3/4) (2-1/4) (32) SOUND POWER LEVEL Model Mode Speed A-Weighted Sound Full Octave Sound Power[dB] Power Level[dB(A)] 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Cool Min 61 70.6 55.0 55.9 55.8 59.0 49.9 41.1 42.9 4A6V8048A Cool Max 74 75.7 71.9 73.0 74.2 68.5 63.4 59.1 54.3 Heat Min 62 72.1 59.3 58.7 60.3 58.6 51.3 46.0 45.2 Heat I Max 1 76 1 77.9 74.5 77.0 75.4 69.5 64.4 60.8 56.2 Note:Rated in accordance with AHRI Standard 270-2008 2 4A6V8048A-SPEC-1 74*erfeAW S*uwd"d HEATING & AIR CONDITIONING OUTDOOR UNIT(a)(b) 4A6V8048A1000A Mechanical Specification Options POWER CONNS.—V/PH/HZ(e) 208/230/1/60 General MIN.BRCH.CIR.AMPACITY 28.0 The Outdoor Units are charged from the factory for BR.CIR.PROT.RTG.—MAX.(AMPS) 40 matched indoor section and up to 15 feet of piping. COMPRESSOR SCROLL This unit is designed to operate at outdoor ambient temperatures from 55'F to 120'F in cooling and from NO.USED—NO.SPEEDS 1-VARIABLE —10'F to 66' F in heating. Only AHRI approved indoor R.L.AMPS(d)—L.R.AMPS 20.3—12.0 matches are approved for use with these models. FACTORY INSTALLED Accu Li n k'' START COM PON ENTS(e) NA This outdoor unit contains the AccuLinkT" digital INSULATION/SOUND BLANKET YES communication with 2 wire connection to outdoor and COMPRESSOR HEAT YES Plug-n-Play set up. OUTDOOR FAN Casing DIA.(IN.)—NO.USED 27.5—1 Unit casing is constructed of heavy gauge. G60 TYPE DRIVE—NO.SPEEDS DIRECT—VARIABLE galvanized steel and painted with a weather-resistant powder paint on all louvers,panels,prepaint on all CFM @ 0.0IN.W.G.M 4467 other panels.Corrosion and weatherproof CMBP-G30 NO.MOTORS—HP 1-1/3 DuraBaseT' base. MOTOR SPEED R.P.M. 200—1200 Refrigerant Controls VOLTS/PH/HZ 208/230/1/60 Refrigeration system controls include condenser fan, F.L.AMPS 2.8 compressor contactor and high and low pressure OUTDOOR COIL—TYPE SPINE FINT`" switches.A factory supplied,field installed filter is standard. ROWS—F.P.I. 1-24 FACE AREA(SQ.FT.) 27.87 Compressor TUBE SIZE(IN.) 3/8 Inverter driven scroll compressor with 25 to 100% output capacity on heat pumps and 30 to 100%output REFRIGERANT R410-A capacity on air conditioners. Noise enclosure LBS.—R-410A(O.D.UNIT)(9) 9 lb—13 oz minimizes sound levels and built in compressor FACTORY SUPPLIED YES protection protects compressor will reduce operating speed and current draw to maintain operation while LINE SIZE—IN.O.D.GAS(h) 7/s protecting the compressor. LINE SIZE—IN.O.D.LIQ.(h) 3/8 Condenser Coil CHARGING SPECIFICATIONS The Spine Fin TM outdoor coil provides low airflow SUBCOOLING 100 resistance and efficient heat transfer.The coil is DIMENSIONS H x W x D protected on all four sides by louvered panels. CRATED(IN.) 46.4 x 35.1 x 38.7 Low Ambient Cooling WEIGHT As manufactured,this system has built in freeze SHIPPING(LBS.) 259 protection that will allow cooling operation below 55°F NET(LBS.) 234 but will reduce capacity or shut down completely to prevent operation under adverse conditions. (a) Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program,which is based on AHRI standard Comfort Control za The 950/850 Control is required and provides Plu n- (b> Ratedted in in accordance with AHRI standard 270. q g (_) Calculated in accordance with Natl.Elec.Codes.Use only HACR Play setup and 3 wire connection. circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max.fuse size.The value shown is the branch circuit selection current. (e) No means no start components.Yes means quick start kit components.PTC means positive temperature coefficient starter. M Standard Air—Dry Coil—Outdoor (9) This value approximate.For more precise value see unit nameplate. (h) Max.linear length 150 ft.;Max.lift—Suction 50 ft.;Max.lift—Liquid 50 ft. 4A6V8048A-SPEC-1 3 1 Unitary Small HP ETA us [ISTEO Intertek AA&Z' " s7�wdard® HEATING & AIR CONDITIONING American Standard optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments,American Standard offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information,visit www.americanstandardair.com. American Standard has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2013 American Standard Heating&Air Conditioning An) 4A6V8048A-SPEC-1 13 Sep 2013 Ingersoll Rand Supersedes(New) CITY OF ARLINGTON e 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 r PHONE; (360)403-3551 BUILDING PERMIT Address: 177271VestCountry Club Drive Permit#: 1208 Parcel rK:00816000004200 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name: DUFFEY JAMES L&DRU E Name:CM Healing Name:CM I[eating Inc Address: 17727 W COUNTRY CLUB DR Address:1415 Broadway Address: 1415 Broadway City,Stale Zip:ARLINGTON,WA 98223-5948 City,Stale Zip: Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CNN I[eating Inc Name: Address: 1415 Broadway Address: City,State,Zip:Everett,WA 98201 City,Stale,Zip: Phone:425-259-0550 Phone: LIC 9: EXP: LIC k: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRICTION AND IN DOING THL WORK AUTI-I0RIZ1-.D THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF TI lE LABOR CODI-'OF TI lE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/I IER DEPUTY AND ALL FEES ARE PAID TT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED, IBCI 10/IRCI 10. SA LI:S TAX iN'O'1'10E:Sales tax relating to construction and construction materials in the City orArlit un t tst c re rlrJ on your sales tax return Ibmi Ind coded City of rlrl jtga n N3 l0 `~ t&(n IkX& 11 b IlLp .za e Signature Print Name Dale a d I y Dale CONDITIONS Approved as submitted. Duct Testing is required per the 2015 Washington State Energy Code R402.4.1.2. Additional requirements: 3" concrete pad with seismic bracing attached to pad, provide electrical disconnect, lines shall be insulated - the use of adhesive tape is not permitted. TI IIS PERMIT AUI'HORIZ.S ONLY THE WORK NOTED-THIS PERMIT COVERS WORK TO BE DONE ON PRI VATE PROPERTY ONLY ANY CONSTRUCTION ON TI Ili PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,FTC)WILL REQUIRE SEPARATE PERMISSION PERMIT FEES Date Description Fee Amount 11/9/2016 Furnace $25.00 11/9/2016 Heat Pump $25.00 11/9/2016 Mechanical Permit Base Fee $25.00 Total Due: S75.00 Total Payment: $75.00 Balance Due: S0.00 CALL FOR INSPECTIONS ItUILDING(360)403-3417 When calling for an inspection please leave the following information: CITY OF ARLINGTON �\ 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:17727 West Country Club Drive Permit#: 1208 Parcel#:00816000004200 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:DUFFEY JAMES L&DRU E Name:CM Heating Name:CM Heating Inc Address: 17727 W COUNTRY CLUB DR Address:1415 Broadway Address: 1415 Broadway City,State Zip:ARLINGTON,WA 98223-5948 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Name: Address: 1415 Broadway Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-259-0550 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: ] OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arli on t st re rtcd on your sales tax return form- and coded City of Arlington#3101. Za to Signature Print Name Date I y Date CONDITIONS Approved as submitted. Duct Testing is required per the 2015 Washington State Energy Code R402.4.1.2. Additional requirements: 3" concrete pad with seismic bracing attached to pad, provide electrical disconnect, lines shall be insulated -the use of adhesive tape is not permitted. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED_THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/9/2016 Furnace $25.00 11/9/2016 Heat Pump $25.00 11/9/2016 Mechanical Permit Base Fee $25.00 Total Due: $75.00 Total Payment: $75.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: BUILDING INSPECTION REPORT — MECHANICAL (RESIDENTIAL) Permit No. 1208 Address: 17727 West Country Club Drive Contractor: CM Heating Owner: Duffey Date: 12/6/2016 N APPROVAL ❑ PARTIAL APPROVAL ❑ CORRECTION ❑ OTHER APPLIANCE: Gas Furnace and Heat Pump CO DETECTOR: © HEAT PUMP/AC UNIT: GAS PIPING: © DISCONNECT: DRIP LEG: ® SEISMIC: VENTING: ® 3" PAD: ACCESS: ® INSULATION/PROTECTION: SHUT-OFF VALVE: Fx DUCTS: N/A L&I: Yes Date: 12/6/2016 Inspector: Kevin Olander Permit#: 1208 Permit Date: 11/07/16 Permit Type: RESIDENTIAL MECHANICAL Project Name: Duffey Applicant Name: CM Heating Applicant Address: 1415 Broadway Applicant, City, State, Zip: Everett,WA 98201 Contact: Meredith Gilbert Phone: 425-259-0550 Email: meredith@cmheating.com Scope of Work: Gas Furnace and Heat Pump Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 11/09/2016 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00816000004200 17727 W COUNTRY CLUB DUFFEY JAMES L 111 Single Family DR &DRU E Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Plumbing CMHEAHL750LP ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Construction CMHEAHL751 W ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION UBI 605890285 ST STE 200 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 12/06/2016 R00.HEAT PUMP/ 12/06/2016 BUILDING Approved AC UNIT FINAL 12/06/2016 ROO.FURNACE 12/06/2016 BUILDING Approved FINAL Fees Fee Description Notes Amount Forced Air Heat fee per Btu $25.00 Heat Pump/Heat Exchangers $25.00 Mechanical Base Permit Fee $25.00 Total $75.00 Attached Letters Date Letter Description 11/09/2016 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 11/09/2016 DEBORAH BAUERS 62213536 cc $75.00 Outstanding Balance $0.00 Notes Date Note Created By: 11/07/2016 Furnace model number ADD2CIOOACV5,heat pump model number 4A6V8048AI O00A. Kristin Foster Uploaded Files Date File Name 12/06/2016 1998637-17727 West Country Club Drive.docx 11/09/2016 1942758-1208 Issued Permit.pdf 11/07/2016 1935790-1208 Application.pdf 11/07/2016 1935791-1208 Heat Pump Specs.pdf