Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18513 59TH AVE NE_BLD1184_2026
� Ay or, COMMERCIAL MECHANICAL r • PERMIT APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF CONSTRUCTION DRAWINGS AND ALL OTHER INFORMATION OUTLINED IN THE MECHANICAL PERMIT SUBMITTAL REQUIREMENTS, IF APPLICABLE. Type of Permit: Q New Installation �+R/eplacement Alteration Project Address: f l�J�.3 _ S9� #� /V C Parcel #: Project Description: Valuation: Owner: 6LI ZS �f Ll.� 1�F- l'l�U- ('1J Phone#: Address: City: State: Zip: Email Address: Q Contact Person: k�`�) L Aup Phone Address: ��w �/�~C,L�-(� _ City: �Lr State: w�� Zip: Email Address: Contractor Name: �'7"', G� Phone#: CgZs) Z52 3Mk Contractor Address: Z(? City: 6 iL State:tdX. Zip: Email: kp o Contact Person: /Le--"U JQ &z Contractor License Number: Expiration: 7 Please indicate type of number of appliances: FURNACE CONDENSING UNIT GAS PIPING OUTLET BOILER HEAT PUMP(multi-split) UNIT HEATER 2- CHILLER HEAT PUMP(mini-split) PAINT BOOTH COOLER HEAT PUMP(other) TYPE I HOOD AC(air cooled) HEAT REJECTION EQUIP _ TYPE II HOOD AC(water cooled) VENTILATION SYSTEM AST AC(evaporator) PACKAGED UNIT UST AC(VRF) DRYER OTHER I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in ith th ws,rules and regulation of the State of Washington. Applicants Signature: Date Applicants Printed Name: Received FOR STAFF USE ONLY 1p OCT 24 zols Permit# tV Amount Received Receipt# Date Received 6/16LP Page 1 of 1 Submittal Single Packaged Convertible Gas/Electric 14 SEER 4YCC4048A1O7OA 4YCC4O48A109OA i TAG: I SAFETY WAR Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. June 2015 4YCC4048A-SUB-1 D-EN (II7/ingersollRand SAFETY SECTION Important—This document contains a wiring I diagram,a parts list,and service information.This is GROUNDING REQUIRED! customer property and is to remain with this unit. Please return to service information pack upon Failure to inspect or use proper service tools may completion of work. result in equipment damage or personal injury. Reconnect all grounding devices.All parts of this ! product that are capable of conducting electrical HAZARDOUS GASES! current are grounded. If grounding wires,screws, straps,clips,nuts,or washers used to complete a Exposure to fuel substances or by-products of path to ground are removed for service,they must incomplete fuel combustion is believed by the be returned to their original position and properly state of California to cause cancer, birth defects,or fastened. other reproductive harm. This warning complies with state of California law, I ■ Proposition 65. UNIT CONTAINS R-410A REFRIGERANT! HAZARDOUS VOLTAGE! Failure to use proper servicetools may result in equipment damage or personal injury. Failure to follow this Warning could result in R-410A operating pressure exceeds the limit of R- property damage,severe personal injury,or death. 22. Proper service equipment is required.Service Disconnect all electric power,including remote using only R-410A Refrigerant and approved POE disconnects before servicing.Follow proper compressor oil. lockout/tagout procedures to ensure the power cannot be inadvertently energized. I SAFETY HAZARD! SAFETYAND ELECTRICAL HAZARD! Operating the unit without the access panels properly installed may result in severe personal Failure to follow this Warning could result in injury or death. property damage,severe personal injury,or death. Do not operate the unit withoutthe evaporator fan These servicing instructions are for use by access panel or evaporator coil access panel in qualified personnel only.To reduce the risk of place. electrical shock,do not perform any servicing other than that contained in these operating Important:Wear appropriate gloves,arm sleeve instructions unless you are qualified to do so. protectors and eye protection when servicing or maintaining this equipment. Important.Air filters and media wheels or plates shall meet the test requirements in UL 900. ©2014 Tra ne 4YCC4048A-SUB-1 D-E N Product Specifications MODEL 4YCC4048A1070A 4YCC4048A1090A Volts/Ph/Hz 208-230/1/60 208-230/1/60 RATED Volts/PH/Hz 208-230/1/60 208-230/1/60 F.L.Amps/L.R Amps 1.51/3.07 1.51/3.07 Performance Cooling 46500 46500 INDOOR FAN- CONSTANTTORQUE CONSTANT BTU (a) TYPE ECM TORQUE ECM Indoor Airflow(CFM) 1600 1600 Dia.x Width(In.) 10.62 X 10.62 10.62 X 10.62 Power Input(KW) 4.09 4.09 Drive/No.Speeds DIRECT/3 DIRECT/3 EER/SEER(BTU/Watt- 11.50/14.00 11.50/14.00 CFM @ 0.0 in,w.g.(9) SEE FAN PERF TABLE SEE FAN PERF Hr. TABLE Sound Power Rating 725 725 PERFORMANCE Motor-HP/R.P.M. 3/4/1050 3/4/1050 )(b) Volts/Ph/Hz 208-230/1/60 208-230/1/60 PERF HEATING(c) F.L.Amps 6 6 Input BTUH-1st Stage 70000 90000 COMBUSTION FAN (Natural Gas)(d) TYPE CENTRIFUGAL CENTRIFUGAL AFUE 81 81 Drive/No.Speeds DIRECT/1 DIRECT/1 Temp.Rise-Min/Max (aF) 30/60 35/65 Motor-HP/R.P.M. 1/34/3290 1/34/3075 Orifice Qty/Drill Sz. 2/#33 3/#37 Volts/Ph/Hz 230/1/60 230/1/60 (Natural Gas) POWER CONN.-V 208-230/1/60 208-230/1/60 FLA .20 .24 Ph/Hz FILTER j NO NO Min.Brch.Clr. 320 320 FURNISHED Fuse FuseAmp Size - . . ze-te Max. Type Recommended THROWAWAY THROWAWAY i (amps) 50 50 Recmd.Face Area(sq. 5.3 5.3 Fuse Size-Recmd. ft)(h) (amps) 50 50 REFRIGERANT R-410 R-410 COMPRESSOR SCROLL SCROLL Charge(lbs.) 7.5 7.5 VOLTS/PH/HZ 208-230/1/60 208-230/1/60 CHARGING R. SPECIFICATIONS AmpsAmps-L.R. 19.6/130.0 19.6/130.0 Subcooling 100 100 Amps OUTDOOR COIL SPINE-FIN SPINE-FIN GAS PIPE SIZE(in.) 1/2 1/2 TYPE Rows/F.P.I 2/24 2/24 DIMENSIONS HXDXW HXDXW Face Area(sq.ft.) 20.54 20.54 Crated(in.) 50 X 47 X 62 50 X 47 X 62 Tube Size(in.) 3/8 3/8 WEIGHT INDOOR COIL- MCHE MCHE Sipping(lbs.)/Net 552/448 557/453 TYPE (lbs.) Rows/F.P.I 2/16 2/16 (a) Rated in accordance with AHRI Standard 210/240.AHRI standard rating conditions are:80 D.B.67 W.B.entering airto indoorcoil.95 D. Face Area(sq.ft.) 3.9 3.9 B.entering air to outdoor coil. Tube Size Width(in.) .81 .81 (b) Sound Power values are not adjusted for AHRI 270-9 5 tonal corrections. Refrigeration Control EXPANSION VALVE EXPANSION VALVE M Ratings shown are for elevations up to 2000 ft.For higher elevations Drain Conn.Size(in.) 3/4 FEMALE NPT 3/4 FEMALE NPT reduce ratings at a rate of 4%per 1000 ft.elevation. (d) Convertible to LPG. OUTDOOR FAN- SWEPT SWEPT M This value is approximate.For more precise value,see Unit TYPE Nameplate. DIA.(IN.) 28.25 28.25 M Standard Air-DryCoil-Outdoor. DRIVE/NO.SPEEDS DIRECT/1 DIRECT/1 M Based on U.S.Government Standard Tests. (h) Filters must be installed in return airstream.Square footages listed CFM @ 0.0 In.w.g.M 4800 4800 are based on 300 f.p.m.face velocity.If permanent filters are used Motor-HP/R.P.M 1/4/825 1/4/825 size per manufacturer's recommendation with a clean resistance of 0.05"W.C. 4YCC4048A-SUB-1 D-E N 3 Outline Drawings Figure 1. 4YCC4042-4060 IIB7.1T 151.31 [SB-91161 I6-3116] Ci " 11.56 - IAIEi [LANGEI (DUCT FLANGE) I T.16 [IIlI61 + Irt N3 TYPICAL (8)SIDES DF IDEFION DUCT OPENINGS 1125.22 ` � 1,+•STI{) -S— INLET INLET 18 03 1IB.2]29 I HIVE 123132] 1321 HOOD B I A.26 -r [9lI61 I1-I5116] SIC n wI w, TYPICAL(8)SIDES OF DONNFLON DUCT OPENINGS INLET TOP SIDE (VITA OF GRAVITY onu[r A zs.+0 ssl.+3 --{ aONT SIQE [11 [21-23l32] -CCNOENSAIE DRAIN FOR 19.0;3,1:FEMALE NPT LEFT SIDE RECOMMENDED SERVICE CLEARANCE MNIIN. ITH O.A. DAMPERIECOH. O BACK SIDE 30+.8[121 762.0 1301 O LEFT SIDE 91+.+1361 1066.8 1+21 RIGHT SIDE 91+.4 1361 - FRONT SIDE 1066.8[+21 - CLEARANCE TO COMBUSTIBLE MATERIAL MNIIH. Y Y BOTTOM 0 BACK SIDE 25.4[1) 1 LEFT SIDE 152.+[6] - FF RIGHT SIDE 304.8[121 Note:The view labeled - FRONT SIDE 30+.8 1121 "Bottom Side"represents the base as viewed looking TOP 91+.+1361 up from underneath the unit. BOTTOM SIDE 4 4YCC4048A-SUB-1 D-EN Outline Drawings Figure 2. 4YCC4042-4060 372.82 0 (14-11/161 o [� (OUTSIDE) 4. _ 4= 12-9/321 RETURN 7322.84 SUPPLY [12-23/321 449.02 (17-11/I61 79.50 (OUTSIDE) 13-1/81 449.02 176.07 [6 15/I6] (17-11/161 (OUTSIDE) BACK DUCT OPENINGS • 530.60 120-7/81 x x 1402.34 -I 155-7/321 (SURFACE AREA) BACK SIDE Height mm/In Approx.Corner Weight-kg/Ibs Shipping Total Unit Center of Gravity mm/In Model Weight Weight A W1 W2 W3 W4 kg/Ibs kg/Ibs 8 C 4YCC4042(060) 898.53[35-3/8] 71.2[1571 46.6[1031 34.6[76] 53.1[117] 252.2[555] 202.0(452] 470.0[18.5] 731.0[28.8] 4YCC4042(090) 898.53[35-3/8) 71.8[158] 47.2[104] 35.2[781 53.6 11181 254.5[5611 207.3[4571 470.0[18.5] 731.0[28.8] 4YCC4048(070) ;1000.13(39-3/8 71.4[1571 44.6[98] 33.2[731 53.9[119] 1 250.3(552] 202.1[448] 433.0[17.0] 743.3[29.3] 4YCC4048(090) 1000.13[39-3/8) 72.0[159] 45.0[99] 33.8(75] 54.4[120] 252.6[557] 205.4[453] 433.0(17.0] 743.3[29.3] 4YCC4060(090) 1000.13[39-3/8 77.1[170] 45 8[101] 34.4[76] 58.3(128] 263.1(580] 215.9[4761 433.0[17.0] 743.3[29.3] 4YCC4060(115) 1000.13[39-3/8 78.0[172] 46.3 1-1021 34.9[77] 59.0[130] 265.8[586] 218.6[482] 414.0[16.3] 635.0[25.0] 4YCC4O48A-SUB-1 D-E N 5 Outline Drawings Figure l 4YCC4042-4060 o � AN-,— 381.00 (151 �Q (INSIDE) 318.75 457.20 �� ' ® RETURN ( 12-9/161 [181 a 457.20 ( INSIDE) SUPPLY [181 75.41 (INSIDE) [2-31/321 75.41 244.09 [2-31/321 381.00 [9-5/81 [151 (INSIDE) BOTTOM DUCT OPENINGS 24V ENTRY ° 359.80 294.02 114-5/321 111-9/161 178.66 ° ° [7-1/321 ° AS LINE ENTRY POWER ENTRY 84.96 FOR 12.70 (1121 N.P.T. 21.78 DIA. HOLE [3-11/321 I GAS CONNECTION 11-3/321 98.66 [3 7/81 121.84 RIGHT SIDE [5-1/321 e 4YCC4048A-SUB-1 D-EN Indoor Fan Performance Table 1. Horizontal Airflow 4YCC4048A1070A EXTERNAL STATIC PRESSURE(IN.WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CFM 1120 1047 980 914 840 758 674 581 - - - HEAT-LOW WATTS 117 126 135 145 156 168 179 188 - - - CFM - 1204 1149 1095 1043 989 926 858 798 -HEAT-HIGH WATTS - 176 185 195 205 216 227 239 249 -COOLING-LOW - CFM 1583 1542 1502 1460 1415 1371 1326 1282 1230 1181 - WATTS 302 313 324 332 345 353 368 376 394 406 - CFM 1763 1723 1689 1648 1609 1568 1527 1488 1447 1404 - COOLING-MED WATTS 414 426 436 448 459 471 483 495 510 524 - COOLING-HIGH CFM 1945 1910 1876 1839 1806 1769 1728 1688 1652 1545 - WATTS 553 566 577 590 601 613 631 643 647 611 - 4YCC4048A3090A EXTERNAL STATIC PRESSURE(IN.WG) CFM 1419 1380 1341 1295 1249 1204 1160 1115 1069 1015 961 HEAT-LOW WATTS 240 250 259 269 279 291 302 312 323 333 348 CFM 1559 1524 1483 1443 1401 1363 1319 1276 1233 1195 1147 HEAT-HIGH WATTS 313 324 335 346 356 367 379 392 403 415 428 CFM 1583 1542 1502 1460 1415 1371 1326 1282 1230 1181 - COOLING-LOW WATTS 302 313 324 332 345 353 368 376 394 406 - CFM 1763 1723 1689 1648 1609 1568 1527 1488 1447 1404 - COOLING-MED WATTS 414 426 436 448 459 471 483 495 510 524 - CFM 1945 1910 1876 1839 1806 1769 1728 1688 1652 1545 - COOLING-HIGH WATTS 553 566 577 590 601 613 631 643 647 611 - Table 2. Down Airflow 4YCC4048A1070A EXTERNAL STATIC PRESSURE(IN.WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CFM 1126 1052 985 918 845 762 677 584 - - - HEAT-LOW WATTS 117 127 136 146 156 168 180 189 - - - CFM - 1210 1154 1100 1048 994 930 862 802 - - HEAT-HIGH WATTS - 177 186 196 206 217 228 240 250 - - COOLING-LOW CFM 1567 1526 1487 1445 1401 1358 1312 1270 1218 1169 - WATTS 308 320 330 339 352 360 375 384 402 413.9 - CFM 1745 1706 1672 1632 1593 1552 1512 1473 1433 1390 - COOLING-MED WATTS 422 434 444 457 468 480 493 505 520 534 - COOLING-HIGH CFM 1925 1890 1857 1821 1788 1751 1711 1671 1635 1530 - WATTS 564 577 589 602 613 625 644 656 660 623 - 4YCC4048A1090A EXTERNAL STATIC PRESSURE(IN.WG) CFM 1426 1387 1348 1301 1255 1210 1166 1120 1074 1020 966 HEAT-LOW WATTS 241 251 260 270 281 292 303 314 325 335 349 CFM 1567 1531 1491 1450 1408 1370 1326 1282 1239 1201 1152 HEAT-HIGH WATTS 315 325 337 347 358 368 381 394 405 417 430 COOLING-LOW CFM 1567 1526 1487 1445 1401 1358 1312 1270 1218 1169 - WATTS 308 320 330 339 352 360 375 384 402 413.9 CFM 1745 1706 1672 1632 1593 1552 1512 1473 1433 1390 COOLING-MED WATTS 422 434 444 457 468 480 493 505 520 534 COOLING-HIGH - CFM 1925 1890 1857 1821 1788 1751 1711 1671 1635 1530 - WATTS 564 577 589 602 613 t 625 644 656 1 660 1 623 - 4YCC4048A-SUB-1 D-E N 7 Full Perimeter Roof Mounting Curb Figure 4. 4042 —4060 Models BAYCURB051A Full Perimeter Roof Mounting Curb 15 7/8 56 1/8 3 RETURN AIR 1 1/2 SUPPLY AIR 10 7/8 19 1/2 20 4 3/4 I 19 1/2 41 7/8 6 14 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only.These drawings are not intended to be used as a basis to construct, build or modify the �' ^\ items depicted in the drawings.The manufacturer i \ is not responsible for the unauthorized use of these \ drawings and expressly disclaims any liability for damages resulting from such unauthorized use. A B � \ \ RETURN \ AIR i \ SUPPLY � AIR D i'\ C i ' \ -CHANNEL SIDE i CHANNEL END \. WOO;D NAILER SERVICE CLEARANCE DIMENSIONS HOLE IN ROOF A I B I CJ D 1 WC*/TC* 42.00 36.00 12.00** 24.00 i 38 7/8 i 53 1/8 DC*/YC* 42 36.00.00 36.00 12.00** \ **42.00 WITH ECONOMIZER WITH 25%FRESH AIR ACCESSORY $ 4YCC4048A-SUB-1 D-EN Optional Equipment — Filter Rack Figure 5. BAYFLTR101 Filter Rack(4024-4036) BAYFLTR201 (4042-4060) (Mounts in Filter/Coil Section) Figure 6. BAYACCD0R1A Hinged Filter Access Door(4024-4036) BAYACCDOR2A(4042-4060) Replaces Filter/Coil Access Panel e f Note:The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only.These drawings are not intended to be used as a basis to construct,build or modify the items depicted in the drawings.The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 4YCC4048A-SUB-1 D-EN 9 Optional Equipment — Economizer Table 3. BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) HVAC Unit Economizer Unit Application Models Economizer e. rain hood o o 0 0 0 o 0 0 o BAYECON101A 4024-036 Outside air dampers Return air dampers e Required L \ filter kit, order Mist +,�\,``` separately eliminator °' . o BAYECON102A 4042-060 Relief Return damper Duct Roofcurb —11 Table 4. BAYCON200,201A Horizontal Economizer and Rain Hood .® Economizer A B C �D Gaskets (2) Duct E �- Rain Hood Mixed Air i Sensor Economizer Models A B C D E F BAYECON200A 4024-4036 22" 20" 16-7/8" 15-11/16" 11-11/16" 15" BAYECON201A 4042-4060 26" 22-21/32" 19" 17-11/16" 14-11/16" 21-3/8" Note:The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only.These drawings are not intended to be used as a basis to construct,build or modify the items depicted in the drawings.The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 10 4YCC4048A-SUB-1 D-E N Optional Equipment — Outside Air Damper Table 5. BAYOSAH001 and 002A I� Manual Fresh Unit Air Model Application A B C D Models i� FULLY I \ OPE\N BAYOSAHOOIA 4024-4036 22-7/16" 20-11/16" 12-3/8" 9-3/16" D f C� FULLV B CLOSED BAYOSAH002A 4042—4060 25-3/16" 20-11/16" 12-3/8" 9-3/16" Table 6. BAYDMPR101 and 102A,25%Motorized Outside Air Damper (Mounts Over Horizontal Return Air Opening) Manual Unit Fresh Air Application A a C D E p Model Models r. �I ' ? BAYDM- PR101A 4024—4036 15-13/16" 11-13/16" 10-1/4" 11-1/2" 12-1/4" C e E ! BAYDM- 4042—4060 18-3/16" 15-1/8" 10-1/4" 11-1/2" 12-1/4" PR102A �- D -► Note:The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only.These drawings are not intended to be used as a basis to construct,build or modify the items depicted in the drawings.The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 4YCC4048A-SUB-1 D-EN 11 Mechanical Specifications General Constant Torgue,forward-curved,centrifugal wheel in The units shall be horizontal airflow as shipped and a Composite Vortica®Blower housing. Motor shall convertible to downflow. have thermal overload protection and permanently lubricated motor bearings. Motor/blower assembly All units shall be factory assembled,piped,internally isolated from unit with rubber mounts. wired and fully charged with refrigerant. Units shall be certified to UL Standard 1995. Units shall be designed Outdoor Fan to operate at ambient temperatures as high as 115°F. One direct-drive,statically and dynamically balanced Cooling performance shall be rated in accordance with propeller fan shall be used in a draw-through vertical AHRI standards.The YC heating/cooling unit design is discharge configuration. Permanently lubricated certified to ANSI 221.47/CSA 2.3,specifically for weather proof motor shall have built-in thermal outdoor applications using natural gas or propane.All overload protection. units shall be designed for outdoor rooftop or ground System Controls level installation. System controls include condenserfan,evaporatorfan Unit Casing and compressor contactors. All components shall be mounted in a weather- Accessories Roof Curb resistant steel cabinet with an enamel finish.Access panels shall be provided for unit controls and indoor The roof curb shall be designed to mate with the unit coil and fans. Indoor air section compartment shall be and provide support and complete weathertight completely insulated with fireproof,permanent, installation when properly installed.Adhesive back odorless fiber material. Knockouts shall be provided for polyurethane sealing strips shall be provided to ensure utility and control connections. Drain connections shall an airtight seal between supply and return openings of be provided to accommodate indoor water runoff. the curb and unit.The roof curb design allows field fabricated ductworkto be connected directlyto the Compressor curb.Curb ships knocked down for field assembly,and The compressor shall be hermetically sealed,high includes factory installed wood nailer strips. efficiency scroll compressors. Internal overcurrent and Heating System overtemperature protection,internal pressure relief Gas-Fired Heating Section shall be standard.Other features include centrifugal oil pump,low vibration and noise. Models shall provide completely assembled,wired and Refrigeration System piped gas fired heating systems within unit. Design certified by UL,specifically for outdoor application. All units shall have refrigerant control.Service pressure Threaded gas connection on the unit. tap ports and a refrigerant line filter shall be standard. Electric Ignition System Evaporator Coil(2-4 Ton Models)All aluminum Main burner is lit each time thermostat calls for heat. micro channel,extruded tubes,mechanically bonded to Flame sensor proves flame and keeps the main burner aluminum fins,and factory pressure and leak tested at on.Should a loss of flame occur,the main valve closes 480 —650 psig.All units have TXV to control refrigerant and the spark recurs within 0.8 seconds.When flow. thermostat is satisfied,main burner is extinquished. Condenser Coil Forced Combustion Blower The Spine Fin TM condenser coil shall be continuously Insures flame stability under varying wind conditions. wrapped,corrosion resistant all aluminum with Gives higher combustion efficiency and location minimum brazed joints.This coil is 3/8"OD seamless flexibility. aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand 2.000 pounds of Heat Exchanger pressure per square inch.The outdoor coil provides Stainless steel tubes.Free floating design. low airflow resistance and efficient heat transfer.The Burners coil is protected on all four sides by louvered panels. Indoor Air Fan Stainless steel. Multi-port inshot. 12 4YCC4048A-SUB-1 D-E N Mechanical Specifications Single Source Power Entry that shall be gravity closing and prohibit entrance of This accessory when used with electric heat accessory outside air on equipment"off'cycle.Economizer shall allow single source power connection to unit and requires BAYRLAY004A relay kit to interface the heater combination.Single source power entry kits economizerto the heat pump. shall have specific matching heater(s). Kit shall include Manual Outside Air Dampers high voltage terminal blocks,fuse blocks and fuses,cut- Rain hood and screen shall be field installed.Suitable to-length interconnecting wiring,and junction box(if for up to 25%outside air. required)to provide power sources with fuse protection as required for both the unit and accessory Start Kit heater. Kit components shall install within the heater Extra compressor starting capacity for single phase cabinet in the heater access section.Single source equipment. branch power circuit shall be protected and wired in Control Options accordance with local codes. Standard Indoor Thermostats Fully Modulating Economizer Two stage heating/cooling or one stage heating/cooling This accessory shall be field installed and be composed thermostats shall be available in either manual or of the following items:0-100%fresh air damper, automatic changeover. damper drive motor,fixed dry bulb enthalpy control, Programmable Electronic Night Setting Thermostat and low voltage pigtails for electrical connections. Solid state enthalpy or differential enthalpy control is Programmable electronic thermostat shall provide optional.Economizer operations shall be controlled by heating setback and cooling setup with 7—day the preset position of the enthalpy control.A programming capability. 1 H/1C or 2H/2C models barometric relief damper shall be standard with the available. economizer and provide a pressure operated damper ETA �S ' Intertek The manufacturer optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments,the manufacturer offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information,visit www.IRCO.com. The manufacturer has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. 02014 Trans 4YCC4048A-SUB-1D-EN 30Jun2015 / Supersedes 4YCC4048A-SUB-IC-EN (February2015) "BlngersollRand ca MODEL CA XAD-4-45-GL Qm' ennnce COMBINATION LOUVER W" • DRAINABLE BLADE. AMCA LICENSED. Standard Construction: Frame: 4"x.081 (101 mm x 2.1 mm)extruded aluminum(6063-T5). 4 Stationary Blades: .060(1.5 mm)extruded aluminum(6063-T5). 101 mm I� approximately 4-3/8"(111 mm)on centers. Adjustable Blades: .080(2 mm)extruded aluminum(6063-T5). Blade Angle: 45' Bearings: Permanently lubricated oilite bronze, t I press fit into frame. Axles: 3/8"(9.5 mm)square plated steel. Linkage: Plated steel concealed in jamb. j Operator: Wing nut side bracket. I Blade Seals: Extruded Vinyl. Jamb Seals: Flexible stainless steel. I Screen: Bird screen-3/4"x.050(19 mm x 1.27 mm)flattened i expanded aluminum in a removable frame on interior of louver. Finish: Mill aluminum. i Minimum Section Size: 8"w x 12"h(203 mm x 305 mm) u Maximum Section Size: 60"w x 96"h(1524 mm x 2438 mm) ° Options: j- Screens: Insect screen- 18 x 16 mesh aluminum Other: Finish: Prime Coat. 4 3/8" Baked Enamel. Clear Anodize-204-R1 &215-R1 1111mm j Integral Color Anodize Kynar 500 Enamel. Other: Sill Extensions: Flange: 1-1/2"(38 mm)(front or rear) Channel Frame Other Operator Notes: Louvers fabricated 1/4"(6.4 mm)under a, opening size unless otherwise noted. 0 0 N LO 7 i cil u Q 1-1/2"1(38 mm) U Visible Sill Flange Jamb Mullion Extension Frame Specifications are correct at time of printing.However,as part of our'continuous improvement program,'we reserve the right to make further improvements without notice. Project: Contractor: Location: Address: Architect: P.O. Number: Engineer: Date: NCA MANUFACTURING, INC. 111 1036 SOUTH JUPITER ROAD ■ GARLAND,TEXAS 75042 0 TEL.972-276-5002 FAX 972-276-6747 MODEL CA XAD-4-45-GL COMBINATION LOUVER A ` DRAINABLE BLADE. AMCA LICENSED. PERFORMANCE DATA Specifications Furnish and install where shown model CA-XAD-4-45-GL louver, manufactured by NCA Manufacturing. Louvers shall be the combination drainable type with a frame depth of 4 inches. Frames and adjustable blade shall be .081 inches thick 6063-T5 extruded aluminum alloy, Stationary blades to be.060 inches thick 6063-T5 extruded aluminum alloy. Blades shall be located on a 45 degree blade angle. Screens shall consist of 3/4"expanded aluminum,with an aluminum frame, mounted to the louver interior, and be removable for cleaning. Louvers shall be finished with Polyurethane Acrylic enamel, Kynar 500, Anodize or other finishes selected by the architect from NCA standard color charts. CA-XAD-4-45-GL FREE AREA IN SQ. FT. Width-Inches 8 12 18 1 24 30 36 42 48 1 54 1 60 12 0.15 0.26 0.41 0.57 0.73 0.89 1.05 1.21 1.37 1.53 18 0.27 0.47 0.76 1.05 1.34 1.63 1.93 2.22 2.51 2.80 24 0.37 0.64 1.04 1.44 1.84 2.24 2.64 3.04 3.44 3.84 30 0.55 0.94 1.52 2.10 2.69 3.27 3.85 4.44 5.02 5.60 36 0.69 1.17 1.90 2.63 3.37 4.10 4.83 5.56 6.29 7.02 m 42 0.79 1.35 2.19 3.03 3.87 4.71 5.56 6.40 7.24 8.08 r 48 0.93 1.60 2.60 3.59 4.59 5.59 6.59 7.58 8.58 9.58 c 54 1.07 1.83 2.96 4.10 5.24 6.38 7.52 8.65 9.79 10.93 60 1.18 2.02 3.28 4.53 5.79 7.05 8.31 9.57 10.82 12.08 66 1.33 2.28 3.69 5.11 6.53 7.95 9,37 10.79 12.20 13.62 = 72 1.45 2.47 4.02 5.56 7.10 8.64 10.18 11.72 13.27 14.81 78 1.57 2.69 4.37 6.04 7.72 9.40 11.07 12.75 14.43 16.11 84 1.72 2.95 4.78 6.62 8.45 10.29 12.13 13.96 15.80 17.64 90 1.79 3.06 4.97 6.88 8.79 10.70 12.61 14.51 16.42 18.33 96 1.97 3.38 5.48 7.59 9.70 11.80 13.91 16.01 18.12 20.23 e rn .7 NCA Manufacturing,Inc, °10 - o s - -- certifies that the Model 0,26 N .5 CA-XAD-4-45-GL louver 75 0 •a shown herein is licensed I to bear the AMCA seal.The ¢ 0.24 ratings shown are based W 0,2 w z on tests and procedures LL a performed in accordance o ON LL with AMCA Publication LL o 0 511 and comply with the ° w 0Cn e requirements of the W o.le 0 .o - - AMCA Certified Ratings N w 0.14 Q - _ program. zZ 0.12 a _ O- Of ,04 The AMCA Certified Seal ~ 0.19 w i applies to air performance D .03 ratings and water W °ae i w / penetration ratings. 0.06 W oz - - a oea a 1 air= 3 002 I CEnTRIED t 01 nnTI0G1 ON 1 2 3 4 5 6 1 6 010 p 30 900 1000 1100 1200 t\ WATER VELOCITY THROUGH FREE AREA FPM VELOCITY THROUGH FREE AREA V fIIR FPM X 100 Water Penetration PRESSURE DROP Water Penetration Data applies to test unit size 48"x 48"only. INTAKE Beginning of Water Penetration is 986 FPM Free Area Velocity. Pressure Drop Data applies to test unit size 48" x 48" only. Performance shown is at standard air density 0.075 lbs./ft'. Performance Data does not include the effects of birdscreen. NCA MANUFACTURING, INC. 0 1036 SOUTH JUPITER ROAD 0 GARLAND,TEXAS 75042 N TEL.972-276-5002 FAX 972-276-6747 Page 1 of 5 Caiddl r INDUSTRIES FAN SUBMITTAL COVER SHEET Date: 10/20/2016 To: EVERGREEN STATE SIM ATTN: KEN Address: Phone: Fax: Email: Project: BOYS&GIRLS CLUB Location: ARLINGTON Engineer: EVERGREEN STATE SIM From: Air Tec Co By: Mike Snorsky Address: 85 South Orcas Phone: 206-763-9911 Fax: 206-763-1950 Email: msnorsky@air ecco.com Comments: m 0 q 0 2 @ \ / ds ƒ \ \ \ > J jco \ / � 00 ^ § � e o ` a. e S J -0 } M — G 5 a) S G C/) � S U) G LL 7 LL mLcl � a. U k o \ $ f J 06 � k k \ >- � 0 ® \ m / k Do / 4 / co clo 2 @ \ I_— / LLI/ O Or3 \\ — m — .2 / 2 U / k U) < E v a « LO 0 q ¢ D @ 2 � n k g ¢ g 2E « k 2 2 3 C) 2 / 2 / � 2 E ± e 2 kLO / E k C 2 LO f En kU) § U) o j 0 k mG » y m 0 k% D = m e / § 2 � � ® k = 2a � m ± cn ~ E G _ E m \u -- / 2 \ (D (D �_ _ cl) a a) .0 � Q < 75=3 = � a c 753 & .9? o c « = e o 7 m u o _ c -0 = o — n o GCD \ / \ 7 g oy : 0 3 ® -C3 m o ƒ § 0) E k cu W e £ 2 n c c » ® ER22 \ : _ M e = 5 / a) § § k m 2 0 a) ca 0 . & > q E f � 0 s Type CRBA TAG: EF-1 Page 4 of 5 • Non-overloading aluminum wheel Belt Drive Centrifugal computer balanced • Force ventilated motor Power Roof Ventilator B DIA. — — — — compartment isolated from airstream Variable pitch motor pulley • Vibration isolators on drive frame • Weatherproof spun aluminum INDUSTRIES housing A NEMA Standard open drip-proof MERICAN COOLAIR CORPORATION motors Accessories • Overlapping wheel/inlet Venturi • Heavy duty self-aligning pillow- A/D MOTORIZED C block bearings with cast iron DAMPER(120/1,POSR - housing INTERNAL MOUNT 1/2"galvanized mesh birdscreen ACTUATOR UL Listed for Standard 705(most models) PFC1 Roof Curb A SQ.I.D. 2• Dimensions in inches A B C unless otherwise noted 46 613/4 1 44114 Weight: 591 lbs. Tip Speed: 4,371 ft/min Outlet Velocity: 897 ftlmin Fan Data Motor Data Accessories Qty Model No. CFM �450 MHP RPM VoltagelPh Hz Encl. PFC1 A/D 1 CRBA36ND8363 11,550 2 1,750 208/230/460V 3PH 60 JOPEN Sones LWA dba dba dba Octave Band Sound Power(LwA) @ 5' @ 10' @ 20' 63 Hz 125 Hz 250 Hz 500 Hz 11000 Hz 2000 Hz 4000 Hz 8000 Hz 12.5 1 72 61 55 49 84 85 72 67 64 58 54 47 Air Density:0.075 IbS/ftA3 AMCA Licensed for Sound and 2. QmCA 1,a0 -•••— -- -- ` 00 Air Performance plAllp Power rating(BHP)does not include transmission losses. Bearing losses are Included. Performance ratings do not Include the effects of appurtenances(accessories). Performance shown is for � Installation Type'A':Free Inlet, V Free outlet The sound ratings shown are N loudness values in American Coolair Corporation certifies that t1,520 - 1.04 hemispherical sones at 1.5 m(5 the Type CRBA units shown herein are i ft.)in a hemispherical free field licensed to bear the AMCA seal.The Ln calculated per AMCA Standard ratings shown are based on tests and 301. procedures performed In accordance with rl, :,.� Values shown are for AMCA Publication 211 and AMCA I ;= Installation Type'A':Free inlet Publication 311 and comply vrilh the Q•25 ,...'................. ._._......—,..��—•'""'""'"""t"""�" ,,�"• 0' 0 hemispherical sone levels requirements of the AMCA certified Ratings I Sound ratings apply to sones Program. _ only. 0,00 0.00 0 2,500 53000 7,500 't0,0o`J 12,500 -15,000 Volume Flow Rate(CFM) Notes: Project: BOYS&GIRLS CLUB Engineer: EVERGREEN STATE S/M Location: ARLINGTON Contractor: EVERGREEN STATE S/M Submitted By: - Date 10/20/2016 Approved By: Date FanSelect 6-July 2016 ver.6.6.0 Page 5 of 5 Type PFC1 and PFC2 Roof Curb Dimensions For Fan Models CRBA - CRBCA - CRDA at INDUSTRIES AMERICAN COOLAIR CORPORATION P.O.Box 2300 Jacksonville,Florida 32203 Phone: (904)389-3646 Fax: (904)387-3449•(904)381-7560 E-mail: fans@coolair.com Internet: www.coolair.com D SQ. H O.D. 1 5/8 J I.D. 1 5/a � 11/2 Thick Insulation jj Wood PFC1 - 8 T Optional Nailer PFC2 - 12 p 1 - Damper Shelf x^ IL 1 G SQ.* Unit Size D G* H J 06, 08, 10 24 1/2 11 1/4 16 1/2 13 1/4 12, 13, 15 29 1/2 16 1/4 21 1/2 18 1/4 16, 18, 20 36 1/2 23 1/4 28 1/2 25 1/4 24 40 1/2 27 1/4 32 1/2 29 1/4 30 46 1/2 33 1/4 38 1/2 35 1/4 36 52 1/2 29 1/4 44 1/2 41 1/4 44 62 1/2 49 1/4 54 1/2 51 1/4 52 71 1/2 58 1/4 63 1/2 60 1/4 * -The Damper Shelf is an optional accessory. Dimensions in inches C7Y �TON OF ARLI �: 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address: 18513 59th Avenue NE Permit#: 1184 Parcel#:31052200103100 Valuation:40000.00 OWNER APPLICANT CONTRACTOR Name:ARLINGTON CITY OF Name:Everegreen State Heat and A/C Name:EVERGREEN STATE HEAT&A/C Address: 18204 59TH DRIVE NE Address:2120 Pacific Ave Address:2120 Pacific Ave City,State Zip:ARLINGTON,WA 98223 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-252-3114 Phone:425-252-31 l4 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:EVERGREEN STATE HEAT&A/C Name: Address:2120 Pacific Ave Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-252-3114 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 0 OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL ORA CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1l0/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form aild cod cd ity 1'Ar'n on#3101. 1 2 '*r-- 12 L�� Si nature Print Name Date Released By D CONDITIONS Approved as submitted. Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.TIES PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION_ PERMIT FEES Date Description Fee Amount 10/31/2016 Furnace $25.00 10/31/2016 Gas Outlets Base Fee 1 to 5 $10.00 10/31/2016 Mechanical Fee(Enter Fixture Fee) $100.00 10/31/2016 Mechanical Permit Base Fee $25.00 10/31/2016 Mechanical Plan Review Fee $400.00 10/31/2016 Vents $25.00 Total Due: $585.00 Total Payment: $0 00 Balance Due: $585.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon I a Inspection Information Inspection Date 10/28/2016 Type Gas Piping Requested By Contact Info Scheduled Date Completion Date 10/28/2016 Description Inspected main line from meter to first"T"KO Status Approved Assigned To Kevin Olander Hours 10 Notes Property Information Parcel# 31052200103100 RLINGTON CITY OF RLINGTON CITY OF 18204 59TH DRIVE NE 18513 59TH AVE NE ARLINGTON WA 98223 31 Airports&Flying Fields Permit Details Date 10/21/2016 Permit Number 1184 Project Name Arlington Boys and Girls Club Applicant Name Everegreen State Heat and A/C Applicant Address 2120 Pacific Ave City, State,Zip Everett,WA 98201 Contact Ken Salo Phone 425-252-3114 Email ken@essmwa.com Permit Type Commercial Mechanical Site Address 18513 59th Avenue NE Valuation 40000.00 Status Completed Permit Issued 10/31/2016 Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 0 Proposed Use HVAC installation for commercial addition Assigned To Kristin Foster Contractors Contractor Name Primary Contact Phone Email Contractor Type License License# EVERGREEN STATE HEAT&A/C Mark Payne 425-252-311 a CONTRACTOR Labor&industries EVERGSS0220T Property Information Owner Information Parcel#:31052200103100 ARLINGTON CITY OF ARLINGTON CITY OF 18204 59TH DRIVE NE 18513 59TH AVE NE ARLINGTON,WA 982231 Inspection Information Inspection Date 12/21/2016 Type Gas Piping Requested By Contact Info Scheduled Date Completion Date 12/21/2016 Description Gas piping to rooftop unit complete.KO 12/21/16 Status Approved Assigned To I Kevin Olander Hours 0 Notes Property Information Parcel# 31052200103100 ARLINGTON CITY OF RLINGTON CITY OF 18204 59TH DRIVE NE 18513 59TH AVE NE ARLINGTON WA 98223 31 Airports&Flying Flytng Fields Permit Details Date 10/21/2016 Permit Number 1184 Project Name Arlington Boys and Girls Club Applicant Name Everegreen State Heat and A/C Applicant Address 2120 Pacific Ave City, State,Zip Everett,WA 98201 Contact Ken Salo Phone 425-252-3114 Email ken@essmwa.com Permit Type Commercial Mechanical Site Address 18513 59th Avenue NE Valuation 40000.00 Status Completed Permit Issued 10/31/2016 Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 0 Proposed Use HVAC installation for commercial addition Assigned To Kristin Foster Contractors Contractor Name Primary Contact Phone Email Contractor Type License License# EVERGREEN STATE HEAT&A/C Mark Payne 1425-252-31141 1 CONTRACTOR I Labor&Industries EVERGSS0220T Property Information Owner Information Parcel#:31052200103100 ARLINGTON CITY OF ARLINGTON CITY OF 18204 59TH DRIVE NE 118513 59TH AVE NE I ARLtNGTON,WA 982231 1 Jim Wahl /t?56-13 6 From: Josh O'Connor Oosho@expertdrywall.com] Sent: Tuesday, January 17, 2017 9:06 AM To: Jim Wahl Cc: Zach Lalone Subject: FW: Exterior Sheathing & Fire Ratings Attachments: U423.pdf; U442.pdf; IBC Section 718 Fireblocking.pdf; U419.pdf Hi Jim, Just got your email address. I sent this to Pete yesterday and he is working on getting with the inspector but wanted you to have the information on hand as well. The email chain below will help explain. Thank you, EXPERT JOSH OTONNOR DRYWALL, INC Estimator/ Project Manager josho@expertdrywall.com 425-478-5112 cell 425-284-1899 fax www.expertdrywall.com 425-284-1890 main From:Josh O'Connor Sent: Monday,January 16, 2017 12:03 PM To: 'Pete Gaffney'<Pete.gaffnev@gaffneyconstructioninc.com> Cc:Zach Lalone<ZachL@expertdrywall.com>; Greg Wright<gregwedi2@ic1oud.com>; Tony Vranich (Tones@expertdrywall.com) <Tonyv@expertdrywall.com> Subject: FW: Exterior Sheathing& Fire Ratings All, I posed a couple questions to our contact at the Northwest Wall and Ceiling Bureau about taping at the exterior walls (specifically the parapet) and head of wall firestopping. My email and his response are both included below. There is a lot of verbiage in these documents but to help sift through everything I have highlighted the pertinent information. U423—See note 5B & note 9 U442—See note 8 U419—See note 5C & 8 The IBC section 718 references the fire blocking. Pete, To get further clarification if necessary could you pass on the attachments to the architect and inspector and ask if they would like us to fire tape the exterior sheathing and also use firestopping at the head of wall at the interior partitions. i i Please let me know if there is anything else I can provide. Thank you, E X P E R T JOSH OTONNOR DRYWALL, I N C Estimator/ Project Manager iosho@expertdrywall.com 425-478-5112 cell (optional) 425-284-1899 fax www.expertdrywall.com 425-284-1890 main From:Terry Kastner(mailto:terry@nwcb.or ] Sent: Monday,January 16, 2017 11:13 AM To:Josh O'Connor<josho@expertdrywall.com> Cc: Zach Lalone<ZachL@expertdrywall.com> Subject: RE: Exterior Sheathing& Fire Ratings Hello Josh, Typically with square edged sheathing or drywall you do not need to tape the joints to achieve the fire rating. See attached examples... I am not aware of any Head of Wall Assemblies for wood construction. For wood assemblies the dimensional lumber provides fire blocking which should address the joint at the head of wall,which is backed by 2 X dimensional lumber... Please confirm with architect....tk Terry Kastner Director of Technical Services, CS1 Northwest Wall & Ceiling Bureau (206) 524-4243 phone (206) 524-4136 fax (206) 399 7399 cell terry@nwcb.org www.nwcb.org From:Josh O'Connor[rnailto:iosho@expertdrvwall.com] Sent: Monday,January 16,2017 9:23 AM To:Terry Kastner<terry@nwcb.org> Cc: Zach Lalone<ZachL(a@expertdrywall.com> Subject: Exterior Sheathing& Fire Ratings 2 i fcVw FA /J A�T�p FRAM xm& ' 'rcL " ~o. -6^ — mmFn6 TWERU wwwWnM ` PMUR UO �� r/" AWonwIwm °/ FOE WINS FRM/NSpR � 57QAnAkAL / 121r / sww s VIE. 'L~V W)A *S S`IMn64RAL :°TM:*m w/oc | my mcR M'AL � 5c15MYC ]��yY�1^ TINSITION ------'-------- Hi Terry, P|easeseethedetai| above.Thisisanexteriornoeta| studvva|\. Thebottonntrackisattachedto8" CMU. VVeare hanging Z layers Of5/8" DeOsGlass Gold on both sides per the details to create a wall with 3 3 hour rating. Also, on the roof side of the "parapet" we will run a bead of firestopping where the sheathing terminates into the TPO. The inspector is recommending we fire tape the joints of the first layer of sheathing to complete the 2 hour rating. Are we required to fire tape the first layer if we stagger the joints on either side of the vva}|? This exterior wall is separating a new building from an existing building. The existing building does not have a sprinkler system. nv Z Question; Are we required to provide firestnppingatthe head of rated vva||s inside wood framed building? Currently ata 2hourratedvva|| vvehave2 |ayersof5/Q" TvpeXdryvva|| onbothsidesofZx4'sandnotchedaroundvvood trusses. The drywall extends to the underside of the roof. Please give me a Call Or let me kOOvv if you have any questions or would like me to elaborate Or clarify anything. Thank you, EXPERT �� 8� U� ~� U����� ��»���������� K- �� �� K~ K"� 0 °�~-""" ~~ `-�="�^~~~"~ DRYWALL, INC Estimator/ Project Manager 4Z5-478'Sl12 cell /opdona|\ 425-284'1899fax | 425-284-1890rnain i 4 4 FIRE AND SMOKE PROTECTION FEATURES 717.7 Flexible ducts and air connectors.Flexible ducts and materials shall not be used as a fireblock unless specifi- air connectors shall not pass through any fire-resistance-rated cally tested in the form and manner intended for use to assembly.Flexible air connectors shall not pass through any demonstrate its ability to remain in place and to retard wall,floor or ceiling, the spread of fire and hot gases. 718.2.1.4 Fireblocking integrity.The integrity of fire- SECTION 718 blocks shall be maintained. CONCEALED SPACES 718.2.1.5 Double stud walls.Batts or blankets of min- 718.1 General. Fireblocking and draftstopping shall be eral or glass fiber or other approved nonrigid materials installed in combustible concealed locations in accordance shall be allowed as fireblocking in walls constructed with this section. Fireblocking shall comply with Section using parallel rows of studs or staggered studs. 718.2. Draftstopping in floor/ceiling spaces and attic spaces 718.2.2 Concealed wall spaces. FireblocA7ng shall be shall comply with Sections 718.3 and 718.4, respectively, provided in concealed spaces of stud walls and partitions, The permitted use of combustible materials in concealed including furred spaces,and parallel rows of studs or stag- spaces of buildings of Type I or II construction shall be lim- gered studs,as follows: iced to the applications indicated in Section 718.5. 1. Vertically at the ceiling and floor levels. 718.2 Fireblocking. in combustible construction,fireblock- ing shall be installed to cut off concealed draft openings(both 2. Horizontally at intervals not exceeding 10 feet(3048 vertical and horizontal) and shall form an effective barrier mm). between floors,between a top story and a roof or attic space. 718.23 Connections between horizontal and vertical Fireblocking shall be installed in the locations specified in spaces.Fireblocking shall be provided at interconnections Sections 718.2.2 through 718.2.7. between concealed vertical stud wall or partition spaces 718.2.1 Fireblocking materials. Fireblocking shall con- and concealed horizontal spaces created by an assembly of sist of the following materials: floor joists or trusses,and between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings, I. Two-inch(51 mm)nominal lumber. cove ceilings and similar locations. 2. Two thicknesses of 1-inch(25 mm)nominal lumber 718.2A Stairways.Fireblocking shall be provided in con- with broken lap joints. cealed spaces between stair stringers at the top and bottom 3. One thickness of 0.719-inch(18.3 mm)wood struc- of the run.Enclosed spaces under stairs shall also comply tural panels with joints backed by 0.719-inch (18.3 with Section 1009.9.3. mm)wood structural panels. 718.24 Ceiling and floor openings. Where required by 4. One thickness of 0.75-inch(19.1 mm)particleboard Section 712.1.7,Exception I of Section 714.4.1.2 or Sec- with joints backed by 0.75-inch (19 mm) particle- tion 714.4.2, fireblocking of the annular space around board. vents,pipes,ducts,chimneys and fireplaces at ceilings and 5. One-half-inch(12.7 mm)gypsum board. floor levels shall be installed with a material specifically tested in the form and manner intended for use to demon- 6. One-fourth-inch(6.4 mm)cement-based millboard. strafe its ability to remain in place and resist the free pas- 7. Batts or blankets of mineral wool,mineral fiber or sage of flame and the products of combustion. other approved materials installed in such a manner 718.25.1 Factory-built chimneys and fireplaces. as to be securely retained in place. Factory-built chimneys and fireplaces shall be fire- ' 8. Cellulose insulation installed as tested for the spe- blocked in accordance with UL 103 and UL 127. cific application. 718.2.6 Exterior wall coverings. Fireblocking shall be 718.2.1.1 Batts or blankets or mineral wool or min- installed within concealed spaces of exterior wall cover- eral fiber.Batts or blankets of mineral%vool or mineral ings and other exterior architectural elements where per- fiber or other approved nonrigid materials shall be per- mitted to be of combustible construction as specified in mitted for compliance with the 10-foot(3048 mm)hor- Section 1406 or where erected with combustible frames. izontal fireblocking in walls constructed using parallel Fireblocking shall be installed at maximum intervals of 20 rows of studs or staggered studs. feet(60%mm)in either dimension so that there will be no 718.2.1.2 Unlaced fiberglass. Unlaced fiberglass batt concealed space exceeding 100 square feet (9.3 m2) insulation used as fireblocking shall fill the entire cross between fireblocking.Where wood furring strips are used, section of the wall cavity to a minimum height of 16 they shall be of approved wood of natural decay resistance inches (406 mm) measured vertically. When piping, or preservative-treated wood. if noncontinuous,such ele- conduit or similar obstructions are encountered, the merits shall have closed ends, with at least 4 inches(102 insulation shall be packed tightly around the obstruc- mm)of separation between sections. tion. Exceptions: 718.2.13 Loose-rill insulation material. Loose-fill I. Fireblocking of cornices is not required in single- insulation material, insulating foam sealants and caulk family divellings. Fireblocking of cornices of a 142 2012 INTERNATIONAL BUILDING CODE' FIRE AND SMOKE PROTECTION FEATURES two-family dwelling is required only at the line of located above and in line with the dwelling unit and sleep- dwelling unit separation, ing unit separations. 2. Fireblocking shall not be required where the Exceptions: exterior wall covering is installed on noncombus- I. Draftstopping is not required in buildings tible framing and the face of the exterior wall equipped throughout with an automatic sprinkler covering exposed to the concealed space is cov- system in accordance with Section 903.3.1.1. ered by one of the following materials: 2. Draftstopping is not required in buildings 2.1. Aluminum having a minimum thickness equipped throughout with an automatic sprinkler of 0.019 inch(05 mm), system in accordance with Section 903.3.1.2, 2.2.Corrosion-resistant steel having a base provided that automatic sprinklers are also metal thickness not less than 0.016 inch installed in the combustible concealed spaces (0.4 mm)at any point. where the draftstopping is being omitted. 2.3.Other approved noncombustible materi- 718.3.3 Other groups.in other groups,draftstopping shall als. be installed so that horizontal floor areas do not exceed 3. Fireblocking shall not be required where the i,000 square feet(93 m'). exterior wall covering has been tested in accor- Exception: Draftstopping is not required in buildings dance with,and complies with the acceptance cri- equipped throughout with an automatic sprinkler sys- teria of, NFPA 285. The exterior wall covering tem in accordance with Section 903.3.1.1. shall be installed as tested in accordance with 718.4 Draftstopping in attics. In combustible construction, NFPA 285. draftstopping shall be installed to subdivide attic spaces and 718.2.7 Concealed sleeper spaces.Where wood sleepers concealed roof spaces in the locations prescribed in Sections are used for laying wood flooring on masonry or concrete 718.4.2 and 718.4.3. Ventilation of concealed roof spaces fire-resistance-rated floors, the space between the floor shall be maintained in accordance with Section 1203.2. slab and the underside of the wood flooring shall be filled 718A.1 Draftstopping materials. Materials utilized for with an approved material to resist the free passage of draftstopping of attic spaces shall comply with Section flame and products of combustion or fireblocked in such a 718.3.1. manner that there will be no open spaces under the floor- ing that will exceed 100 square feet (9.3 m=) in area and 718.4.1.1 Openings.Openings in the partitions shall be such space shall be filled solidly under permanent parti- protected by srequired f loots with automatic latches tions so that there is no communication under the flooring constructed as required for the partitions. between adjoining rooms. 718.4.2 Groups R-1 and R-2.Draftstopping shall be pro- Exceptions: vided in attics, mansards, overhangs or other concealed roof spaces of Group R-2 buildings with three or more 1. Fireblocking is not required for slab-on-grade dwelling units and in all Group R-1 buildings. Draftstop- floors in gymnasiums. ping shall be installed above, and in line with, sleeping 2. Fireblocking is required only at the juncture of unit and dwelling unit separation walls that do not extend each alternate lane and at the ends of each lane in to the underside of the roof sheathing above. a bowling facility. Exceptions: 7183 Draftstopping in floors.In combustible construction, i. Where corridor walls provide a sleeping unit or draftstopping shall be installed to subdivide floor/ceiling dwelling unit separation,draftstopping shall only assemblies in the locations prescribed in Sections 718.3.2 be required above one of the corridor walls. through 718.3.3. 2. Draftstopping is not required in buildings 7183.1 Draftstopping materials.Draftstopping materials equipped throughout with an automatic sprinkler shall not be less than'/.inch(12.7 mm)gypsum board.'/r system in accordance with Section 903.3.1.1. inch (9.5 mm) wood structural panel, 3/,-inch (9.5 mm) particleboard, i-inch (25-mm) nominal lumber, cement 3. In occupancies in Group R-2 that do not exceed fiberboard,butts or blankets of mineral wool or glass fiber, four stories above grade plane, the attic space or other approved materials adequately supported. The shall be subdivided by drajtsrops into areas not integrity of drajtsrops shall be maintained. exceeding 3.000 square feet (279 m) or above every two dwelling units,whichever is smaller. 7183.2 Groups R-1, R-2, R-3 and RA Draftstopping shall be provided in floor/ceiling spaces in Group R-1 4. Draftstopping is not required in buildings buildings, in Group R-2 buildings with three or more equipped throughout with an automatic sprinkler dwelling units,in Group R-3 buildings with two dwelling system in accordance with Section 903.3.1.2, units and in Group R-4 buildings. Draftstopping shall be provided that automatic sprinklers are also installed in the combustible concealed space where the draftstopping is being omitted. 2012 INTERNATIONAL BUILDING CODE* 143 iit BXUV.U419-Fire-resistance Ratings - ANSI/UL 263 Page 1 of 8 ut ONLINE CERTIFICATIONS nigFCTOF}:Y Design No. U419 BXUV.U419 Fire-resistance Ratings- ANSI/UL 263 pane Boltont Design/System/Construction/Assembly Usage Disclaimer • Authorities Having Jurlsdlctlon should be consulted in all cases as to the particular requirements covering the Installation and use of UL CertiRLd products,equipment,system,devices,and materials. • Authorities Having Jurisdiction should be consulted before construction. • Fire resistance assemblies and products are developed by the design submltter and have been Investigated by UL for compliance with applicable requirements The pubilshed Information cannot always address every construction nuance encountered in the Held. When neld Issues arise,It Is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the des,gn.Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies.The Guide Information Includes specifics concerning alternate materials and alternate methods of construction. • Only products which bear UVs Mark are considered Certified. BXUV- Fire Resistance Ratings -ANSI/UL 263 BXUV?- Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada See Gen1Eal Information for Fire resistance Ratings-ANSIZUIL 263 See General Information for Fire Resistance Ra Ina•-CAN/UI C- 101 Certified for Canada Design No. U419 May 28,2015 Nonbearing Wall Ratings—1,2,3 or 4 Mr(See Items 4 d 5 through 5K) Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certffkation(such as Canada),respectively. 4 1 C r1 5 \ -+-� t 8e rj+ 5 S6J �ti c ,x xYYx x 5 y ina) 1.Floor and Ceiling Runners—(Not shown)—For use with Item 2-Channel shaped,fabricated from min 25 MSG correslon-protected steel,min depth to accommodate stud size,with min 1-1/4 In.long legs,attached to floor and telling with fasteners 24 In,OC max. 1A.Framing Members"'-Floor and Ceiling Runner—Not shown-In lieu of Item 1—For use with Item 28, proprietary channel shaped runners,3.5/8 In.deep attached to floor and telling with Fasteners 24 In.OC max. http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/show... 8/19/2015 BXUV.U419 -Fire-resistance Ratings -ANSI/UL 263 Page 2 of 8 CALIFORNIA EXPANDED METAL PRODUCTS CO—Vlper25"Track CRACO MFG INC—SmartTrack25" MARINO/WARE,DIV OF WARE INDUSTRIES INC—Viper25'"Track PHILLIPS MFG CO L L C—Viper251"Track 1B.Framing Members*-Floor and Calling Runner—Not shown-In lieu of Item 1—For use with Item 2C, proprietary channel shaped runners,1-1/4 In.wide by 3-5/8 In.deep fabricated from min 0.020 In.thick galv steel, attached to floor and calling with fasteners spaced 24 In.OC max. CALIFORNIA EXPANDED METAL PRODUCTS CO—Vlper20"'Track MARINO/WARE,DIV OF WARE INDUSTRIES INC—Vlper201"Track PHILLIPS MFG CO L L C—Viper201"Track IC.Framing Members'—Floor and Calling Runners—(Nat shown)—In lieu of Item 1-Channel shaped,attached to floor and ceiling with fasteners 24 In.CC.max. ALLSTEEL✓,GYPSUM PRODUCTS INC—Type SUPREME Framing System CONSOLIDATED FABRICATORS CORP,BUILDING PRODUCTS DIV—Type SUPREME Framing System QUAIL RUN BUILDING MATERIALS INC—Type SUPREME Framing System SCAFCO STEEL STUD MANUFACTURING CO—Type SUPREME Framing System STEEL CONSTRUCTION SYSTEMS INC—Type SUPREME Framing System UNITED METAL PRODUCTS INC—Type SUPREME Framing System 11).Floor and Calling Runners—(Not shown)—For use with Item 2A-Channel shaped,fabricated from min 20 MSG corrosion-protected or gaiv steel,min depth to accommodate stud size,with min 1 in long legs,attached to floor and ceiling with fasteners spaced max 24 1n,OC. IE.Framing Members*—Floor and Ceiling Runners—(Nat shown,As an alternate to Item 1)—For use with Items 2E,SF or SG or 51 only,channel shaped,fabricated from min.0.015 In.(min bare metal thickness)galvanized steel, attached to Moor and calling with fasteners 24 In.CC.max - CLARKDIETRICH BUILDING SYSTEMS—CD ProTRAK DMFCWBS L L C—ProTRAK MBA METAL FRAMING—ProTRAK RAM SALES L L C—Ram ProTRAK STEEL STRUCTURAL PRODUCTS L L C—Trl-S PraTRAK 1F.Framing Members*-Floor and Calling Runner—Not shown-in lieu of Item 1—For use with Item 2F, proprietary channel shaped runners,minimum width to accommodate stud size,with 1-1/8 In.long legs fabricated from min 0.015 in.(min bare metal thickness)gaiv steel,attached to floor and ceiling with fasteners spaced 24 In.OC max. SUPER STUD BUILDING PRODUCTS—The Edge 1G.Framing Members*-Floor and Ceiling Runner—For use with Item 2G,proprietary channel shaped runners, minimum width to accommodate stud size attached to floor and ceiling with fasteners 24 in.OC max. STUDCO BUILDING SYSTEMS—CROCSTUD Track IH.Floor and Calling Runners—(Not shown)—Channel shaped,fabricated from min 0.02 In.galv steel,min width to accommodate stud size,with min 1 In.long legs,for use with studs specified below and fabricated from min 0.02 In.gaiv steel or thicker,attached to floor and ceiling with fasteners spaced max 24 In.OC. MARINO/WARE,DIV OF WARE INDUSTRIES INC—VIpe20-Track VT100. 11.Framing Members•—Floor and Calling Runners—(Not shown,As an alternate to Item 1)—For use with Items 2H,channel shaped,fabricated from min.0.015 In.(min bare metal thickness)galvanized steel,attached to floor and ceiling with fasteners 24 In.OC.max. TELLING INDUSTRIES L L C—TRUE-TRACK'" http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/show... 8/19/2015 �I BXUV.U419 -Fire-resistance Ratings - ANSI/LJL 263 Page 3 of 8 11.Framing Membars*-Floor and Calling Runner—Not shown-In lieu of Item 1—For use with Item 21, proptietary channel shaped runners,3-5/8 In.deep attached to floor and ceiling with fasteners 24 In.OC max. TELLING INDUSTRIES L L C—Vlper251"Track 1K.Framing Members*-Floor and Ceiling Runner—Not shown-In lieu of Item 1—For use with Item 21, proprietary channel shaped runners,1-1/4 in.wide by 3-5/8 In.deep fabricated from min 0.020 In.thick galv steel, attached to Floor and ceiling with fasteners spaced 24 in.OC max. TELLING INDUSTRIES L L C—Vlper20'"Track 2.Steal Studs—Channel shaped,fabricated from min 25 MSG corrosion-protected steel,min depth as Indicated under Item 5,spaced a max of 24 In.OC.Studs to be cut 3/8 to 3/4 In.less than assembly height. 2A.Steal Studs—(As an alternate to Item 2,For use with Items 5B,SE,SH,53 and 5K)Channel shaped,fabricated from min 20 MSG corrosion-protected or galv steel,3-1/2 In,min depth,spaced a max of 16 In.OC.Studs friction-fit into floor and ceiling runners.Studs to be cut 5/8 to 3/4 In.less than assembly height 28.Framing Members*-Steel Studs—(As an alternate to Item 2,For use with Items 5C,51 or 5K)-Proprietary channel shaped studs,3-5/8 In.deep spaced a max of 24 In.OC,Studs to be cut 3/4 In less than the assembly height and installed with a 1/2 In.gap between the end of the stud and track at the bottom of the wall,For direct attachment of gypsum board only. CALIFORNIA EXPANDED METAL PRODUCTS CO—Vlper251" CRACO MFG INC—Smart5tud25'" MARINO/WARE,DIV OF WARE INDUSTRIES INC—Vlper2S'" PHILLIPS MFG CO L L C—Vlper251" 2C.Framing Members*-Steel Studs—Not shown-In lieu of Item 2—proprietary channel shaped steel studs,min depth as Indicated under Item 5,spaced a max If 24 In.OC,fabricated from min 0.020 In.thick galv steel.Studs cut 3/8 In.to 3/4 In.less In lengths than assembly heights. CALIFORNIA EXPANDED METAL PRODUCTS CO—Vlper20'1 MARINO/WARE,DIV OF WARE INDUSTRIES INC—Vlper20'" PHILLIPS MFG CO L L C—Vlper20'" 2D.Framing Members*—Steel Studs—In lieu of Item 2-Channel shaped studs,min depth as Indicated under Item 5,spaced a max of 24 In.OC.Studs to be cut 3/4 In.less than assembly height. ALLSTEEL&GYPSUM PRODUCTS INC—Type SUPREME Framing System CONSOLIDATED FABRICATORS CORP,BUILDING PRODUCTS DIV—Type SUPREME Framing System QUAIL RUN BUILDING MATERIALS INC—Type SUPREME Framing System SCAFCO STEEL STUD MANUFACTURING CO—Type SUPREME Framing System STEEL CONSTRUCTION SYSTEMS INC—Type SUPREME Framing System UNITED METAL PRODUCTS INC—Type SUPREME Framing System 2E.Framing Members*—Steel Studs—(Not shown,As an alternate to Item 2)—Far use with Items SF or 5G or 51 or 5K only,channel shaped studs,min depth as Indicated under Item 5F,SG or 51,fabricated from min.0.015 in.(min bare metal thickness)galvanized steel,spaced a max of 24 In,OC.Studs to be cut 3/4 In.less than assembly height. CLARXDIETRICH BUILDING SYSTEMS—CD PrOSTUO DMFCWBS L L C—ProSTUD MBA METAL FRAMING—ProSTUD RAM SALES L L C—Ram ProSTUD STEEL STRUCTURAL PRODUCTS L L C—Trl-S ProSTUD http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/show... 8/19/2015 BXUV.U419 -Fire-resistance Ratings -ANSIM 263 Page 4 of 8 2F. m Framing Mobers'-Steel Studs—Not shown-In lieu of Item 2—proprietary channel shaped steel studs, minimum width Indicated under Item 5,1-1/4 in.deep fabricated from min 0.015 In.(min bare metal thickness) galvanized steel.Studs 3/8 In.to 3/4 In.less In lengths than assembly heights. SUPER STUD BUILDING PRODUCTS—The Edge 2G.Framing Members*-Steel Studs—Not shown-In lieu of Item 2-proprietary channel shaped studs,minimum width Indicated under Item 5,Studs to be cut 3/8 to 3/4 In less than the assembly height. STUDCO BUILDING SYSTEMS—CROCSTUD 2H.Framing Members*—Steel Studs—(Not shown,As an alternate to Item 2)—Fabricated from min.0.015 In. (min bare metal thickness)galvanized steel,spaced a max of 24 In.OC.Studs to be cut 3/4 in.less than assembly height. TELLING INDUSTRIES L L C—TRUE-STUD'" 21.Framing Members--Steel Studs—(As an alternate to Item 2,For use with Items SC or SL or SK)-Proprietary channel shaped studs,3.5/8 In,deep spaced a max of 24 In.OC.Studs to be cut 3/4 In less than the assembly height and Installed with a K In.gap between the end of the stud and track at the bottom of the wall.For direct attachment of gypsum board only. TELLING INDUSTRIES L L C—Vlper25'" 21.Framing Members*-Metal Studs—Not shown-In lieu of Item 2—proprietary channel shaped steel studs,min depth as Indicated under Item 5,spaced a max If 24 In.OC,fabricated from min 0.020 In.thick galy steel.Studs cut 3/8 In,to 3/4 In.less In lengths than assembly heights TELLING INDUSTRIES L L C—Vlper20` 2K.Framing Members—Steel Studs—As an alternate to Item 2-For use with Item 1,channel shaped studs, fabricated from min 25 MSG corrosion-protected steel,min depth as Indicated under Item 5,spaced a max of 24 In.OC. Studs to be cut 3/8 to 3/4 In.less than assembly height. EB MbTAL INC—ES Stud 2L.Framing Members*—Steel Studs—As an alternate to Item 2-For use with Item 1,channel shaped studs, fabricated from min 25 MSG corrosion-protected steel,min depth as Indicated under Item 5,spaced a max of 24 In.OC. Studs to be cut 3/8 to 3/4 In.less than assembly height. OLMAR SUPPLY INC—PRIMESTUD 2M.Framing Members*—Steel Studs—As an alternate to Item 2-For use with Item 1,channel shaped studs, fabricated from min 25 MSG corrosion-protected steel,min depth as Indicated under Item 5,spaced a max of 24 In.OC. Studs to be cut 3/0 to 3/4 In,less than assembly height. MARINO/WARE,DIV OF WARE INDUSTRIES INC—StudRlte'" 3.Wood Structural Panel Sheathing—(Optional,For use with Item 5 Only.)-(Nat Shown)-4 it wide,7116 In.thick oriented strand board(OSB)or 15/32 In.thick structural 1 sheathing(plywood)complying with DOC PSI or PSZ,or APA Standard PRP-108,manufactured with exterior glue,applied horizontally or vertically to the steel studs.Vertical Joints centered on studs,and staggered one stud space from wallboard joints.Attached to studs with flat-head self-drilling tapping screws with a min.head dlam.of 0.292 In.at maximum 6 In.OC.in the perimeter and 12 in.CC.In the field. When used,fastener lengths for gypsum panels Increased by min.1/2 In. 4.Batts and Blankets-—(Required as Indicated under Item 5)—Mineral wool batts,friction fitted between studs and runners.Min nom thickness as Indicated under Item S.See Betts and Blankets(BKNV or BZIZ)Categories for names of Classified companies. 4A.Batts and Blankets*—(Optional)—Placed In stud cavities,any glass fiber or mineral wool Insulation bearing the UL Classification Marking as to Surface Burning Characteristics and/or Fire Resistance.See Batts and Blankets(BKNV or BZJZ)Categories for names of Classified companies. 4B.Batts and Blankets*—For use with Item SK.Placed In stud cavities,any min,3-1/2 In,thick glass fiber Insulation bearing the UL Classification Marking as to Surface Burning Characteristics and/or Fire Resistance.See Batts and Blankets(BKNV or BZIZ)Categories for names of Classified companies. S.Gypsum Board*—Gypsum panels with beveled,square or tapered edges,applied vertically or horizontally.Vertical Joints centered over studs and staggered one stud cavity on opposite sides of studs.Vertical joints In adjacent layers (multilayer systems)staggered one stud cavity.Horizontal Joints need not be backed by steel framing.Horizontal edge joints and horizontal butt Joints on opposite sides of studs need not be staggered.Horizontal edge Joints and horizontal butt Joints In adjacent layers(muitiiayer systems)staggered a min of 12 In.The thickness and number of layers for the 1 hr,2 hr,3 hr and 4 hr ratings are as follows: Gypsum Board Protactlon on Each Side of Wall Min No.of Min Stud Layers Thkns of Depth,In. RThkns Insulation Rating,Hr Items 2,2C,2D,2F and 26 of Panel (Item 4) 1 3-1/2 1 layer,5/8 In.thick Optional 1 2-1/2 1 layer,1/2 in.thick 1-1/2 in. 1 1-5/8 1 layer,3/4 In.thick Optional 2 1.5/8 2 layers,1/2 in,thick Optional 2 1-5/8 2 layers,5/8 in.Mktr Optional 2 3-1/2 1 layer,314 in.thkdk 3 In. 3 1-5/8 3 layers,1/2 in.thick Optional http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/show... 8/19/2015 r I BXUV.U419 -Fire-resistance Ratings -ANSI/UL 263 Page 5 of 8 3 11-5/8 2 layers,3/4 in.thick Optional 3 1-5/8 3 layers,5/8 In.thick Optional 4 1-5/8 4 layers,5/8 In.thick Optional 4 1-5/8 4 layers,1/2 In.thick Optional 4 2-1/2 2 layers,3/4 In.thick 2 In. CGC INC—1/2 In.thick Type C,IP-X2 or IPC-AR;WRC,5/8 In.thick Type AR,C,IP-AR,IP-XI,IP-X2,IPC-AR,SCX, SHX,WRX or WRC;3/4 In.thick Types IP-X3 or ULTRACODE UNITED STATES GYPSUM CO—1/2 In.thick Type C,lP-X2,IPC-AR or WRC;5/8 In,thick Type SCX,SGX,SHX,WRX, IP-XI,AR,C,WRC,FRX-G,IP-AR,IP-X2,IPC-AR;3/4 In.thick Types 1P-X3 or ULTRACODE USG MEXICO S A DE C V—1/2 In,thick Type C,IP-X2,IPC-AR or WRC;5/8 In.thick Type AR,C,IP-AR,IP-XI,IP-X2, IPC-AR,SCX,SHX,WRX,WRC or;3/4 In,thick Types IP-X3 or ULTRACODE When Item 7B,Steel Framing Members',Is used,Nonbearing Wail Rating Is limited to 1 Hr.Min.stud depth Is 3-1/2 In., min.thickness of Insulation(Item 4)is 3 In.,and two layers of gypsum board panels(1/2 In.or 5/8 In.thick)shall be attached to furring channels as described In Item 6.One layer of gypsum board panels(1/2 In.or 5/8 In.thick)attached to opposite side of stud without furring channels as described In Item 6. SA.Gypsum Board*—(As an alternate to Item 5)—5/8 In.thick,24 to 54 In.wide,applied horizontally as the outer layer to one side of the assembly.Secured as described In Item 6. CGC INC—Type SHX. UNITED STATES GYPSUM CO—Type FRX-G,SHX. USG MEXICO S A DE C V—Type SHX 5B.Gypsum Board*—(Not Shawn)-As an alternate to Item 5 when used as the base layer on one or both sides of wall when 5/8 In or 34 In.thick products are specified.For direct attachment only to steel studs Item 2A,(not to be used with Item 3)-Nom 5/8 In.or rA In.may be used as alternate to all 5/8 In.or Vr In.shown In Item 5,Wallboard Protection an Each Side of Wall table.Nom 5/8 In.or V4 In.thick lead backed gypsum panels with beveled,square or tapered edges,applied vertically.Vertical joints centered over studs and staggered min 1 stud cavity on apposite sides of studs.Gypsum board secured to 20 MSG steel studs Item 2A with 1-1/4 In.long Type S-12 steel screws spaced 8 In.OC at perimeter and 12 In.OC In the field.To be used with Lead Batten Strips(see Item 11)or Lead Discs or Tabs(see Item 12). RAY-BAR ENGINEERING CORP—Type RB-LBG 5C.Gypsum Board'—(For Use With Item 28)Rating UmRed to 1 Hour.5/8 in.thick,48 in.wide,Gypsum panels with beveled,square or tapered edges,applied vertically or horizontally.(Vertical Application)-The gypsum board Is to be Installed on each side of the studs with 1 In.long Type 5 coated steel screws spaced B In.OC starting 4 In.from the edge of the board at the vertical edges and 12 In.OC starting 6 In.from the edge of the board at the center of each board. Gypsum boards are to be secured to the top and bottom track with screws spaced 8 in.OC starting 4 In.from the board edge.Fasteners shall not penetrate through both the stud and the track at the same time.Vertical joints are to be centered over studs and staggered one stud cavity on opposite sides of studs.(Horizontal Application)-The gypsum board Is to be Installed on each side of the studs with 1 In.long Type 5 coated steel screws spaced 8 In.OC starting 4 In. from the edge of the board at the vertical edges and 12 In.OC starting 6 In.from the edge of the board at the center of each board.Gypsum boards are to be secured to the top and bottom track with screws spaced B In.OC starting 4 In. from the board edge.Fasteners shall not penetrate through bath the stud and the track at the same time.All horizontal joints are to be backed as outlined under section VI of Volume 1 In the Fire Resistive Directory. CGC INC—Type SCX. UNITED STATES GYPSUM CO—Type SCX,SGX. USG MEXICO S A DE C V—Type SCX. 5D.Gypsum Board•—(As an alternate to Item 5)—5/8 In.thick,48 In.wide,applied vertically or horizontally. Secured as described In Item 6.For use with Items 1 and 2 only. CGC INC—Type USGX.UNITED STATES GYPSUM CO—Type USGX. DensGlass Gold - 5/8" USG MEXICO S A DE C V—Type USGX. SE.Gypsum Boards—(Nat Shown)-(As an alternate to Item 5 when used as the base layer on one or both sides of wall when 1/2 In.or 5/8 In thick products are specified,For direct attachment only to steel studs Item 2A,not to be used with Item 3).Nominal 5/8 In.thick lead backed gypsum panels with beveled,square or tapered edges,applied vertically. Vertical joints centered over studs and staggered min 1 stud cavity on opposite sides of studs.Wallboard secured to studs with 1-1/4 In.long Type 5-12(or No.6 by 1-1/4 In.long bugle head fine driller)steel screws spaced 8 In.OC at perimeter and 12 In.OC in the field. NEW ENGLAND LEAD BURNING CO INC,DBA NELCO—Nelm SF.Gypsum Board*—(As an alternate to Item 5)—For use with Items IE and 2E and limited to 1 Hour Rating only, Gypsum panels with beveled,square or tapered edges,applied vertically,and fastened to the steel studs with 1 In.long http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/show... 8/19/2015 i BXUV.U419 -Fire-resistance Ratings-ANSI/LJL 263 Page 6 of 8 Type S screws spaced 8 In.OC along vertical and bottom edges and 12 In.OC In the field.Vertical joints centered over studs and staggered one stud cavity on opposite sides of studs.Steel stud depth shall be a minimum 3-5/8 In. UNITED STATES GYPSUM CO—5/8 In.thick Type SCX,SGX. 5G.Gypsum Board*—(As an alternate to Item 5)—For use with Items 1E and 2E only,Gypsum panels with beveled, square or tapered edges,applied vertically or horizontally,as specified In the table below and fastened to the steel studs as described In Item 6.Vertical joints centered over studs and staggered one stud cavity on opposite sides of studs. Vertical joints In adjacent layers(multllayer systems)staggered one stud cavity.Horizontal joints need not be backed by steel framing.Horizontal edge Joints and horizontal butt joints on opposite sides of studs need not be staggered. Horizontal edge joints and horizontal butt joints In adjacent layers(multllayer systems)staggered a min of 12 In,The thickness and number of layers for the 2 hr,3 hr and 4 hr ratings are as follows: Gypsum Board Protection on Each Side of Wall Min Stud No.of Layers Min Thkns of Rating, Depth,In. •Thickness Insulation Mr Item 2E of Panel (Item 4) 2 1-5/8 2 layers,1/2 In.thick Optional 2 1-5/8 2 layers,5/8 In.thick Optional 3 1-5/0 3 layers,1/2 In.thick Optional 3 1-5/8 3 layers,5/8 In.thick Optional 4 1-5/8 4 layers,5/6 in,thick Optional 4 1-5/8 4 layers,1/21n.thick Optional CGC INC—1/2 In,thick Type C,IP-X2 or IPC-AR;,5/8 In.thick Type AR,C,IP-AR,IP-XI,IP-X2,IPC-AR,SCX,SHX,or; 3/4 in.thick Types IP-X3 or ULTRACODE UNITED STATES GYPSUM CO—2/2 In.thick Type C,IP-X2,]PC-AR or;5/8 in.thick Type SCX,SGX,SHX,IP-XI,AR, C,,FRX-G,IP-AR,IP-X2,IPC-AR;3/4 In.thick Types IP-X3 or ULTRACODE USG MEXICO S A DE C V—1/2 in,thick Type C,IP-X2,]PC-AR or;5/8 In.thick Type AR,C,IT-Aft,IP-XI,IP-X2,]PC- AR,SCX,SHX,or;3/4 In.thick Types IP-X3 or ULTRACODE SH.Gypsum Board*—(Not Shown)-(As an alternate to Item 5 when used as the vase layer on one or bath sides of wall when 5/8 or 3/4 In thick products are specified.For direct attachment only to steel studs Item 2A,(not to be used with Item 3)-Nam 5/8 or 3/4 In,may be used as alternate to all 5/8 or 3/4 In.shown In Item 5,Wallboard Protection an Each Side of Wall table.Nam 5/8 or 3/4 In.thick lead backed gypsum panels with beveled,square or tapered edges, applied vertically.Vertical joints centered over 20 MSG steel studs and staggered min 1 stud cavity on opposite sides of studs.Wallboard secured to studs with 1-1/4 in.long Type S-12 steel screws spaced 8 in.OC at perimeter and 12 in.OC In the field.Gypsum board secured to 20 MSG steel studs Item 26 with 1-1/4 in.long Type 5-12 steel screws spaced 8 In.OC at perimeter and 12 in.OC In the field.For Joint Compound see Item S.To be used with Lead Batten Stops(see Item 11A)or Lead Disks(see Item 12A). MAYCO INDUSTRIES INC—Type X-Ray Shielded Gypsum 51.Gypsum Board*—(As an alternate to Item 5)-Nam.5/8 in.thick gypsum panels with beveled,square or tapered edges Installed as described In Item S.Steel stud minimum depth shall be as indicated In Item S. CGC INC—Type ULX UNITED STATES GYPSUM CO—Type ULX USG MEXICO S A DE C V—Type ULX SJ.Gypsum Board*—(Not Shown)-(As an alternate to Item 5 when used as the base layer on one or both sides of wall when 1/2 In.or 5/8 in thick products are specified,For direct attachment only to steel studs Item 2A,not to be used with Item 3).Nam 5/8 in,thick lead hacked gypsum panels with beveled,square or tapered edges,applied vertically. Vertical joints centered over studs and staggered min 1 stud cavity on opposite sides of studs.Wallboard secured to studs with 1.1/4 In.long Type 5-12 steel screws gypsum panel steel screws spaced 8 In.OC at perimeter and 12 In.OC In the field.Lead batten strips required behind vertical joints of lead backed gypsum wallboard and optional at remaining stud locations,Lead batten strips,min 2 In.wide,max 8 It long with a max thickness of 0.14 In.placed on the face of studs and attached to the stud with construction adhesive and two 1 In.long Type S-12 pan head steel screws,one at the top of the strip and one at the bottom of the strip.Lead disks,nominal 3/8 In.dlam by max 0.085 in.thick. Compression fitted or adhered over the screw heads.Lead batten strips and discs to have a purity of 99.9%meeting the Federal specification QQ-L-201f,Grade"C". RADIATION PROTECTION PRODUCTS INC—Type RPP-Lead Uned Drywall SK.Gypsum Board*—(Not Shown)-(As an alternate to Item 5)-Nam.5/8 In.thick gypsum panels with beveled, square or tapered edges,applied vertically or horizontally.Vertical joints centered over studs and staggered one stud cavity on opposite sides of studs.Vertical joints In adjacent layers(multllayer systems)staggered one stud cavity. Horizontal joints need not be backed by steel framing.Horizontal edge joints and horizontal butt joints on opposite sides of studs need not be staggered.Horizontal edge joints and horizontal butt joints in adjacent layers(multllayer systems) need not be staggered.The number of layers for the 1 hr,2 hr,3 hr and 4 hr ratings are as follows. Gypsum Board Protection on Each Side of Wall Min No.of min Stud Layers Thkns of Depth,In. &Thkns Insulation Rating,Mr items 2 through 2L of Panel (Item 40) 1 3-5/8 1 layer,5/B in.thick 3-1/2 in. http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/show... 8/19/2015 BXUV.U419 -Fire-resistance Ratings - ANSI/UL 263 Page 7 of 8 2 1-5/8 1 2 layers,5/8 In.thick Optional 3 1-5/8 3 layers,5/8 In.thick Optional 4 1-5/B 4 layers,SIB In.thick Optional UNITED STATES GYPSUM CO—5/8 In.thick Type ULIX 6.Fasteners—(Not shown)—For use with Items 2 and 2F-Type S or S-12 steel screws used to attach panels to studs (Item 2)or furring channels(Item 7).Single layer systems:1 In.long for 1/2 and 5/8 In.thick panels or 1-1/4 In,long for 3/4 In.thick panels,spaced B In.OC when panels are applied horizontally,or 81n.OC along vertical and bottom edpea and 12 In.OC In the field when panels are applied vertically.Two layer systems:First layer-1 In.long for 1/2 and 5/8 In.thick panels or 1-1/4 in,long for 3/4 In.thick panels,spaced 16 In.OC.Second layer-1-5/8 In.long for 1/2 In.,5/8 In.thick panels or 2-1/4 In.long for 3/4 In.thick panels,spaced 16 In.OC with screws offset 8 In.from first layer.Three-bayer systems:First layer-1 In.long for 1/2 In.,5/8 In.thick panels,spaced 24 In.OC.Second layer- 1-5/8 In,long for 1/2 In.,5/8 In.thick panels,spaced 24 in.OC.Third layer-2-1/4 in,long for 1/2 In.,5/8 In.thick panels or 2-5/8 In,long for 5/8 In.thldc panels,spaced 12 In.OC.Screws offset min 6 In,from layer below.Four-layer systems:First layer-1 In.long for 1/2 In.,5/8 In.thick panels,spaced 24 In.OC.Second layer-1-5/8 In,long for 1/2 In.,5/8 In.thick panels,spaced 24 In,OC.Third layer-2-1/4 In.long for 1/2 In.thick panels or 2-5/8 In.long for 5/8 in. thick panels,spaced 24 In.OC.Fourth layer-2-5/8 In.long for 1/2 In.thick panels or 3 In.long for 5/8 In.thick panels, spaced 12 In.OC.Screws offset min 6 In.from layer below. 6A.Fasteners—(Not shown)-For use with Item 5K-Type S or 5-12 steel screws used to attach panels to studs or furring channels(Item 7).Single layer systems:1 in,long screws,spaced 8 In.OC when panels are applied horizontally, or 8 In.OC along vertical and bottom edges and 12 In.OC in the field when panels are applied vertically.Two layer systems:First layer-1 In.long$clews,spaced 16 In.OC.Second layer-1-5/8 In.screws,spaced 8 In.OC with screws offset 8 In.from first layer,Three-layer systems:First layer-1 In.long suews,spaced 24 In.OC.Second layer-1-5/8 in. long screws,spaced 24 in.OC.Third layer-2-5/8 In.long screws,spaced B in.OC.Screws offset min 6 In.from layer below.Four-layer systems:First layer-1 In,long screws,spaced 24 In.OC.Second layer-1-5/6 In.long screws,spaced 24 In.OC.Third layer-2-5/8 In.long screws,spaced 24 In.OC.Fourth layer-3 In.long screws,spaced 8 In.OC.Screws offset min 6 In.from layer below. 7.Furring Channels—(Optional,not shown,for single or double layer systems)—Resilient furring channels fabricated from min 25 MSG corrosion-protected steel,spaced vertically a max of 24 In.OC.Flange portion attached to each Intersecting stud with 1/2 In.long Type S-12 steel screws.Not for use with Item SA and SE. 7A.Framing Members*—(Optional on one or both sides,not shown,for single or double layer systems)—As an alternate to Item 7,furring channels and Steel Framing Members as described below: a.Furring Channels—Formed of No.25 MSG galv steel.2-9/16 in.or 2-23/32 In.wide by 7/8 In.deep,spaced max.24 In.OC perpendicular to studs.Channels secured to studs as described In Item b.Gypsum board attached to furring channels as described In item 6.Not for use with Item SA and 5E. b.Steel Framing Members*—Used to attach furring channels(Item 7Aa)to studs(Item 2). Clips spaced max.48 In.OC.RSIC-1 and RSIC-1(2.75)clips secured to studs with No.8 x 1-1/2 In,minimum self-drilling,S-12 steel screw through the center grommet.RSIC-V and RSIC-V (2.75)dips secured to studs with No.8 x 9/16 In.minimum self-drilling,S-12 steel screw through the center hole.Furring channels are friction fitted Into dips.RSIC-1 and RSIC-V clips for use with 2-9/16 In.wide furring channels.RSIC-1(2.75)and RSIC-V(2.75)clips for use with 2-23/32 in.wide furring channels. PAC INTERNATIONAL INC—Types RSIC-1,RSIC-V,RSIC-1(2,75),RSIC-V(2.75). 7B.Framing Members*—(Optional,Not Shown)—As an alternate to Item 7,for single or double layer systems, furring channels and Steel Framing Members on only one side of studs as described below: a.Furring Channels—Formed of No.25 MSG gaiv steel,spaced 24 In.OC perpendicular to studs.Channels secured to studs as described In Item b.Batts and Blankets placed In stud cavity as described In Item S.Two layers of gypsum board attached to furring channels as described in Item S.Not for use with Item SA and SE. b.Steel Framing Members"—Used to attach furring channels(Item 711a)to one side of studs (Item 2)only.Clips spaced 48 In.OC.,and seared to studs with two No.8 x 2-1/2 In.coarse drywall screws,one through the hole at each end of the dip.Furring channels are friction fitted Into dips. KINETICS NOISE CONTROL INC—Type Isomax 7C.Framing Members*—(Nat Shown)—(Optional on one or both sides,not shown,for single or double layer systems)—As an alternate to Item 7,furring channels and Steel Framing Members as described below: a.Furring Channels—Formed of No.25 MSG galv steel.2-3/8 In.wide by 7/8 In.deep,spaced max.24 In.OC perpendicular to studs.Channels secured to studs as described In Item b. Gypsum board attached to furring channels as described in Item 6.Not for use with Item SA and 5E. b.Steel Framing Members•—Used to attach furring channels(Item 7Aa)to studs(Item 2). Clips spaced max.48 In.OC.GENIECLIPS secured to studs with No.8 x 1-1/2 In.minimum self- drilling,S-12 steel screw through the center grommet.Furring channels are friction fitted Into clips. PLITEQ INC—Type GENIECLIP 7D.Steel Framing Members—(Optional,Not Shown)*-Furring channels and resilient sound Isolation clip as described below: a.Furring Channels—Formed of No.25 MSG gale steel.Spaced 24 In.OC perpendicular to studs.Channels secured to studs as described In Item b.Ends of adjoining channels overlapped 6 in.and secured together with four self-tapping No.8x1/2 Self Drilling screws(2 per side 1 In,and 4 in.from overlap edge).Gypsum board attached to furring channels as described In Item 4.Side joint furring channels shall be attached to studs with RESILMOUNT Sound Isolation Clips-located approximately 2 In.from each end of length of channel.Both Gypsum Boards at side joints fastened Into channel with screws spaced 8 In.OC,approximately 1/2 In.from joint edge.Not for use with Item SA and SE. b.Steel Framing Members*—Resilient sound Isolation dip used to attach furring channels (Item 7Da)to studs.Clips spaced 24 In.OC.,and seared to studs with No.10 x 2-1/2 In.coarse drywall screw through the center hole.Furring channels are friction fitted into dips. STUDCO BUILDING SYSTEMS—RESILMOUNT Sound Isolation Clips-Type A237 or A237R http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/show... 8/.19/2015 i i i BXUV.U419 -Fire-resistance Ratings - ANSI/UL 263 Page 8 of 8 8.Joint Tape and Compound—Vinyl or casein,dry or premixed joint compound applied In two coats to joints and screw heads of outer layers.Paper tape,nom 2 in.wide,embedded in first layer of compound over all joints of outer layer panels.Paper tape and joint compound may be omitted when gypsum panels are supplied with a square edge. 9.Siding,Brick or Stucco—(Optional,not shown)—Aluminum,vinyl or steel siding,brick veneer or stucco,meeting the requirements of local code agencies,Installed over gypsum panels.Brick veneer attached to studs with corrugated metal wall ties attached to each stud with steel screws,not more than each sixth course of brick. 10.Caulking and Sealants-—(Optional,not shown)—A bead of acoustical sealant applied around the partition perimeter for sound control. UNITED STATES GYPSUM CO—Type AS 11.Lead Batten Strips—(Not Shown,For Use With Item SB)-Lead batten strips,min 1-1/2 In.wide,max 10 R long with a max thickness of 0.125 In.Strips placed an the Interior face of studs and attached from the exterior face of the stud with two 1 in,long Type S-12 pan head steel screws,one at the top of the strip and one at the bottom of the strip. Lead batten strips to have a purity of 99.9%meeting the Federal specification QQ-L-201f,Grade"C".Lead batten strips required behind vertical joints of lead backed gypsum wallboard(Item 58)and optional at remaining stud locations. Required behind vertical joints. 11A.Lead Batten Strips—(Nat Shown,For Use With Item SH)Lead batten strips,2 In.wide,max 10 ft long with a max thickness of 0.140 In.Strips placed on the face of studs and attached to the stud with two min.1 In.long min.Type 5-0 pan head steel screws,one at the top of the strip and one at the bottom of the strip or with one min.1 in.long min. Type S-8 pan head steel screw at the top of the strip.Lead batten strips to have a purity of 99.5%meeting the Federal specification QQ-L-201f,Grades"S,C or D".Lead batten strips required behind vertical joints of lead backed gypsum wallboard and optional at remaining stud locations. 12.Lead Discs or Tabs—(Not Shown,For Use With Item 50)-Used In lieu of or In addition to the lead batten strips (Item 11)or optional at other locations-Max 3/4 In,diam by max 0.125 In.thick lead discs compression fitted or adhered over steel screw heads or max 1/2 In.by 1-1/4 in.by max 0.125 In.thick lead tabs placed on gypsum boards (Item SB)underneath screw locations prior to the Installation of the screws.Lead discs or tabs to have a purity of 99.9% meeting the Federal specification QQ-L-201f,Grade"C". 12A.Lead Discs—(Not Shown,for use with Item 5H)Max 5/16 In.them by max 0.140 In.thick lead discs compression fitted or adhered over steel screw heads.Lead discs to have a purity of 99.5%meeting the Federal Speclficetion QQ-L- 201f,Grades"B,C or D". 13.Lead Batten Strips—(Not Shown,For Use With Item 5E)Lead batten strips,2 In.wide,max 10 R long with a max thickness or 0.142 In.Strips placed on the face of studs and attached to the stud with two min.1 In.long min.Type S-8 pan head steel screws,one at the top of the strip and one at the bottom of the strip or with one min.1 In.long min. Type 5-8 pan head steel screw at the top of the strip.Lead batten strips to have a purity of 99.9%meeting the Federal specification QQ-L-201f,Grade"C".Lead batten strips required behind vertical joints of lead backed gypsum wallboard (Item SE)and optional at remaining stud locations. 14.Lead Tabs—(Not Shown,For Use With Item 5E)2 In wide,5 in long with a max thickness of 0.142 In.Tabs friction-fit around front face of stud,the stud folded back Flange,and the back face of the stud,Tabs required at each location where a screw(that secures the gypsum boards,Item SE)will penetrate the steel stud.Lead tabs to have a purity of 99.9%meeting the Federal specification QQ-L-201f,Grade"C".Lead tabs may be held In place with standard adhesive tape If necessary. •Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada),respectively. Last Updated on 2015-05-28 Ouestlons7 Print tt LJ_0i1110 Terms of Use Paae Tao ®2015 UL LLC The appearance of a company's name or product In this database does not In itself assure that products so identified have been manufactured under UL's Follow-Up Service.Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service.Always look for the Mark on the product. UL permits the reproduction of the material contained In the Online Certification Directory subject to the following conditions:1.The Guide Information,Assemblies,Constructions,Designs,Systems,and/or Certifications(flies)must be presented In their entirety and In a non- misleading manner,without any manipulation of the data(or drawings).2.The statement"Reprinted from the Online Certifications Directory with permission from UL"must appear adjacent to the extracted material.In addition,the reprinted material must Include a copyright notice In the following format:"p 2015 UL LLC". http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/show,.. 8/19/2015 BXUV.U442 - Fire Resistance Ratings - ANSIML 263 Page 1 of 3 r U� ONLINE CERTIFICATIONS DIRECTORY BXUV.U442 Fire Resistance Ratings - ANSI/UL 263 Paae Bottom Design/System/Construction/Assembly Usage Disclaimer • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Listed or Classified products,equipment,system,devices,and materials. • Authorities Having Jurisdiction should be consulted before construction. • Fire resistance assemblies and products are developed by the design submitter and have been Investigated by UL for compliance with applicable requirements.The published information cannot always address every construction nuance encountered in the field. • When field issues arise,it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design.Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies.The Guide information includes specifics concerning alternate materials and alternate methods of construction. • Only products which bear UL's Mark are considered as Classified,Listed,or Recognized. Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings-ANSI/m 2e,.i Design No.U442 April 02,2011 Nonbearing Wall Rating—1 HR. �'.1.:`i "'i.'hi::»'yea."�Y,i�e-'..;:w:,L'.C.«s"F7.::' '�:uA�^rn^r�...'�'' ' /...,7T.1.,'. ..r-T.:1c:ti."ft7iliw7wa7w�e`..+:...r.. •,•�.i ••' 04.fi.4 la.•),�.1 S!+.i4,i l • A - •3:.iRl.MS.L 1M1'.IrYt •tLY: }fis wt•Ac.*n i31) 1.Studs—Channel shaped,2-1/2 In.wide by 1-1/4 In,deep with 3/16 in.folded back return flange legs.Fabricated from No.20 MSG (0,0329 in.,min,bare metal thickness)galy steel.Max stud spacing 16 in. OC. Studs to be cut 3/8 to 3/4 In. http://database.ul.com/cgi-biii/XYV/template/LISEXT/1 FRAME/showpage.htrnl?name=B... 4/18/2011 BXUV.U442 - File Resistance Ratings - ANSI/UL 263 Page 2 of 3 less than assembly height. 2.Floor and Ceiling Runners—(Nat Shown)---Channel shaped runners,2-1/2 in.wide by 1-1/4 in.deep,fabricated from No.20 MSG(0.0329 In., min. bare metal thickness)galv steel,Attached to floor and Ceiling with fasteners,24 in.OC max. 3.Cementitious Backer Units* — 1/2 or 5/8 in.thick,applied vertically or horizontally with vertical Joints centered over studs and staggered one stud cavity on opposite sides of studs. Horizontal joints need not be backed by framing.Fastened to studs and bottom runners with the uppermost screws palced 1/2 In,to 2 In. below the bottom edge of the leg of the top runner with corrosion resistant 1-1/4 in.long chamfered,ribbed wafer head screws with a minimum head diameter of.400 inch,spaced 8 in.OC.Joints covered with glass fiber mesh tape and latex modified portland cement mortar or Type I organic adhesive, UNITED STATES GYPSUM CO—DUROCK Exterior Cement Board or DUROCK Brand Cement Board. 4. Batts and Blankets*—Min 2-1/2 in.thick mineral wool insulation batts,friction-fitted between studs. THERMAFIBER INC—Type SAFB. 5,Bond Coat for Setting Tile—Latex modified portland cement mortar or,1 Type I organic adhesive applied with a notched trowel. 6.Ceramic Tile— 1/4 in. thick,joints filled with grout. 7.Gypsum Board*—5/8 in.thick with square or tapered edges,applied vertically with vertical joints Centered over studs and staggered one stud cavity on opposite sides of studs.Fastened with 1 in.long,Type 5-12 screws spaced 8 in.OC along the vertical edges and 12 in. OC in the field,and fastened to runners with screws spaced 8 in.OC. AMERICAN GYPSUM CO—Type AGX-1, M-Glass or AG-C. BEIJING NEW BUILDING MATERIALS PUBLIC LTD CO—Type DBX-1. CANADIAN GYPSUM COMPANY—Type AR,C,IP-AR,IP-X1,JP-X2, IPC-AR,SCX, SHX,WRC,WRX. CERTAINTEED GYPSUM INC—Types EGRG,GlasRoc,ProRoc Type X, ProRoc Type C,SilentFX. CERTAINTEED GYPSUM CANADA INC--ProRoc Type C,ProRoc Type X or ProRoc Type Abuse-Resistant GEORGIA-PACIFIC GYPSUM L L C—Types 5,6,9,C,DA,OAP,DAPC, DGG,DS,GPFS6. LAFARGE NORTH AMERICA INC—Types LGFC2,LGFC2A,LGFC6, LGFC6A,LGFC-C,LGFC-C/A, LGFC-WD. NATIONAL GYPSUM CO—Type FSW-6 NATIONAL GYPSUM CO—Riyadh,Saudi Arabia—Type FR,or WR. PASCO BUILDING PRODUCTS L L C, DBA PASCO GYPSUM--Type C,PG-11 or PG-9. PANEL REY S A—Types PRX, RHX,MOX,ETX. SIAM GYPSUM INDUSTRY(SARASURI)CO LTD—Type EX-1 TEMPLE-INLAND—Type TG-C,Type X,Veneer Plaster Base-Type X, Water Rated-Type X,Sheathing Type-X,Soffit-Type http://database.ul.com/cgi-bin/XYV/template/LISEXT/I FRAME/showpage.html?name=B... 4/18/2011 , BXUV.U442 - Fire Resistance Ratings - ANSI/UL 263 Page 3 of 3 X,GreenGlass Type X,Type X ComfortGuard Sound Deadening Gypsum Board. UNITED STATES GYPSUM CO—Type AR,C,FRX-G, IP-AR,1P-X1, IP-X2,IPC-AR,SCX,SHX,WRC,WRX,USGX(Joint tape and compound,Item 8,optional for use with Type USGX). USG MEXICO S A DE C V—Type AR,C,IP-AR,IP-X1,IP-X2, [PC-AR,SCX,SHX,WRC,WRX. 7A.Gypsum Board*—(As an alternate to Item 7)— 5/8 in.thick with square or tapered edges,applied vertically or horizontally with vertical joints centered over studs.Horizontal edge joints and horizontal butt joints need not be staggered on opposite faces or backed by steel framing.For horizontal application,fastened to studs and floor runners with 1 in.long Type S-screws spaced 8 in.OC.For vertical application,fastened to studs with 1 in.long,Type S-screws spaced 8 in.OC along the vertical edges and 12 in.OC in the field,and fastened to the floor runners with screws spaced 8 in.OC.When used in widths other than 48 in.,gypsum panels to be installed horizontally. CANADIAN GYPSUM COMPANY—Type AR,C,IP-AR,IP-XI,IP-X2,IPC-AR,SCX,SHX,WRC,WRX. CERTAINTEED GYPSUM INC—ProRoc Type X, ProRoc Type C. CERTAINTEED GYPSUM CANADA INC—ProRoc Type X,ProRoc Type C. UNITED STATES GYPSUM CO—Type AR,C,FRX-G,IP-AR,IP-XI,IP-X2,IPC-AR,SCX,SHX,WRC,WRX,USGX(Joint tape and compound,Item 8,optional for use with Type USGX). USG MEXICO S A DE C V—Type AR,C,IP-AR,IP-X1,IP-X2,IPC-AR,SCX,SHX,WRC,WRX. 7B.Wall and Partition Facings and Accessories*—(As an alternate to Items 7 through 7A)—Nominal 5/8 in.thick,4 It wide panels,applied vertically and secured as described in Item 7. SERIOUS MATERIALS INC—Types QuietRock ES,QuietRock 527. 8.Joints—When taper edge gypsum board is used,joints covered with paper tape and joint compound.As an alternate, gypsum veneer plaster may be applied to the entire surface of Classified veneer baseboard with joints reinforced.When square-edge gypsum panels are used used,treatment of joints is optional. 9.Vapor Retarder,Water Barrier or Weather Resistive Barrier—(Optional—Not Shown)—As required. *Bearing the UL Classification Mark Last Updated on 2011-04-02 Ouestions? Print this pace Notice of Disclaimer Page Too Copvrioht ID 2011 Underwriters Laboratories Inc.@ The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service.Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1.The Guide Information,Designs and/or Listings(files)must be presented in their entirety and in a non-misleading manner,without any manipulation of the data(or drawings). 2.The statement"Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc."must appear adjacent to the extracted material.in addition,the reprinted material must include a copyright notice in the following format: "Copyright O 2011 Underwriters Laboratories Inc.@" i , :n d:; a n dr.II I n i I i 1 i u it :r o i k i n q r U 1 .,o I r., :a n r d .y I I r 1 n 1 r: _!i i; P r u r:i:1 c a n d k q n c d g c http://database.ul.com/egi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=B... 4/18/2011 Submittal Single Packaged Convertible Gas/Electric 14 SEER 4YCC4048A1070A 4YCC4048A1090A OFFICE CITY OF ARLINGTQN BUILDING DEPARTMENT APPROVED DAM44J Received NO C ANCEs AUD40WED frMfl M APPROVED BY THE 0 C T 21 2016 BUILDING INSPECTOR TAG: ASAFETYWARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. June 2015 4YCC4048A-SUB-1 D-EN (AR—)IngersollRand UU,MTRAg30 0141 UUG Q3VOAyq_A 0Asac"Ho014 Stq YO awe aa3J$*u POT039alm aU11Q,lIUA r SAFETY SECTION Important—This document contains a wiring diagram,a parts list,and service information.This is GROUNDING REQUIRED! customer property and is to remain with this unit. Please return to service information pack upon Failure to inspect or use proper service tools may completion of work. result in equipment damage or personal injury. Reconnect all grounding devices.All parts of this ! ' product that are capable of conducting electrical HAZARDOUS GASES! current are grounded. If grounding wires,screws, straps,clips,nuts,or washers used to complete a Exposure to fuel substances or by-products of path to ground are removed for service,they must incomplete fuel combustion is believed by the be returned to their original position and properly state of California to cause cancer,birth defects,or fastened. other reproductive harm. This warning complies with state of California law, Proposition 65. UNIT CONTAINS R-410A REFRIGERANT! HAZARDOUS VOLTAGE! Failure to use proper service tools may result in equipment damage or personal injury. Failure to follow this Warning could result in R-410A operating pressure exceeds the limit of R- property damage,severe personal injury,or death. 22. Proper service equipment is required.Service Disconnect all electric power,including remote using only R-410A Refrigerant and approved POE disconnects before servicing.Follow proper compressor oil. lockout/tagout procedures to ensure the power cannot be inadvertently energized. AWARNINGSAFETY HAZARD! SAFETYAND ELECTRICAL HAZARD! Operating the unit without the access panels properly installed may result in severe personal Failure to follow this Warning could result in injury or death. property damage,severe personal injury,or death. Do not operate the unit withoutthe evaporator fan These servicing instructions are for use by access panel or evaporator coil access panel in qualified personnel only.To reduce the risk of place. electrical shock,do not perform any servicing otherthan that contained in these operating Important:Wear appropriate gloves,arm sleeve instructions unless you are qualified to do so. protectors and eye protection when servicing or maintaining this equipment. Important.Air filters and media wheels or plates shall meet the test requirements in UL 900. ©2014 Trane 4YCC4048A-SUB-1 D-E N Product Specifications MODEL 4YCC4048AI070A 4YCC4048A1090A Volts/Ph/Hz 208-230/1/60 208-230/1/60 RATED Volts/PH/Hz 208-230/1/60 208-230/1/60 F.L.Amps/L.R Amps 1.51/3.07 1.51/3.07 Performance Cooling 46500 46500 INDOOR FAN- CONSTANTTORQUE CONSTANT BTU 0) TYPE ECM TORQUE ECM Indoor Airflow(CFM) 1600 1600 Dia.x Width(in.) 10.62 X 10.62 10.62 X 10.62 Power Input(KW) 4.09 4.09 Drive/No.Speeds DIRECT/3 DIRECT/3 E7 RISEETZ(BTU/Watt- 11.50/14.00 11.50/14.00 CFM @ 0.0 in.w.g.(9) SEE FAN PERF TABLE SEE FAN PERF Hr.) TABLE Sound Power Rating 72 5 72 5 Motor-HP/R.RM. 3/4/1050 3/4/1050 [dB(A)](b) PERFORMANCE Volts/Ph/Hz 208-230/1/60 208-230/1/60 HEATING(c) F.L.Amps 6 6 Input BTUH-1st Stage (Natural Gas)N) 70000 90000 COMBUSTION FAN -TYPE CENTRIFUGAL CENTRIFUGAL AFUE 81 81 Drive/No.Speeds DIRECT/1 DIRECT/1 (IFjp.lose-Min/Max 30/60 35/65 Motor-HP/R.P.M. 1/34/3290 1/34/3075 Orifice Qty/Drill Sz. 2/#33 3/#37 Volts/Ph/Hz 230/1/60 230/1/60 (Natural Gas) POWER CONN.-V/ 208-230/1/60 208-230/1/60 FLA .20 .24 Ph/Hz FILTER/ Min.Brch.Cir. FURNISHED NO NO Ampacity(e) 32.0 32.0 Type Recommended THROWAWAY THROWAWAY Fuse Size-Max. (amps) 50 50 Recmd.Face Area(sq. Fuse Size-Recmd. ft)(h) 5.3 5.3 (amps) 50 50 REFRIGERANT R-410 R-410 COMPRESSOR SCROLL SCROLL Charge(lbs.) 7.5 7.5 VOLTS/PH/HZ 208-230/1/60 208-230/1/60 CHARGING SPECIFICATIONS R.L.Amps-L.R. 19.6/130.0 19.6/130.0 Subcoolin 10° 100 Amps 9 OUTDOOR COIL- SPINE-FIN SPINE-FIN GAS PIPE SIZE(in.) 1/2 1/2 TYPE Rows/F.P.I 2/24 2/24 DIMENSIONS H X D X W H X D X W Face Area(sq.ft.) 20.54 20.54 Crated(in.) 50 X 47 X 62 50 X 47 X 62 Tube Size(in.) 3/8 3/8 WEIGHT INDOOR COIL- MCHE MCHE Shipping(lbs.)/Net 552/448 557/453 TYPE I(lbs.) Rows/F.RI 2/16 2/16 (a) Rated in accordance with AHRI Standard 210/240.AHRI standard rating conditions are:80 D.B.67 W.B.entering air to indoor coil.95 D. Face Area(sq.ft.) 3.9 3.9 B.entering airto outdoor coil. Tube Size Width(in.) .81 .81 (b) Sound Power values are not adjusted for AHRI 270-95 tonal corrections. Refrigeration Control EXPANSION VALVE EXPANSION VALVE (c) Ratings shown are for elevations up to 2000 ft.For higher elevations Drain Conn.Size(in.) 3/4 FEMALE NPT 3/4 FEMALE NPT reduce ratings at a rate of 4%per 1000 ft.elevation. (d) Convertible to LPG. OUTDOOR FAN- SWEPT SWEPT (e) This value is approximate.For more precise value,see Unit TYPE Nameplate. DIA.(IN.) 28.25 28.25 M Standard Air-DryCoil-Outdoor. DRIVE/NO.SPEEDS DIRECT/1 DIRECT/1 (9) Based on U.S.Government Standard Tests. (h) Filters must be installed in return air stream.Square footages listed CFM @ 0.0 in.w.g.(f) 4800 4800 are based on 300 f.p.m.face velocity.If permanent filters are used Motor-HP/R.P.M 1/4/825 1/4/825 size per manufacturer's recommendation with a clean resistance of 0.051,W.C. 4YCC4048A-SUB-1 D-EN 3 1 Outline Drawings Figure 1. 4YCC4042-4060 I/B7.IT [615T.37 TSB-91161 -31161 c -� 11.536 INLET [IS/2] (DUCT FLANGE I IF IB I I v l6e W2�- N3 SECTION TYPICAL (B)SIDES OF SIDEFLON DUCT OPENINGS 112. 111•5 S/2216I � INLET INLET IB.O3 IB.29 MLOO�O 123/32] T2]I J2] B 19/16) 201.61 11•IS/l61 WI W, SECTION - TYPICAL (B)SIDES OF DOWNFLOW DUCT OPENINGS INLET TOP SIDE \'Elf(I OF GRAVITY OUTLET A zs.10 ss1.0 -•I FRONT SIDE fll 121-23/321 ONOCNSATE DRAIN FOR IS.O 13141 FEMALE NPT LEFT SIDE RECOMMENDED SERVICE CLEARANCE MM/IN. WITH O.A. DAMPER/ECON. O BACK SIDE 304.6(12) 762.O 1301 O LEFT SIDE 914-4[361 1066.8 1421 RIGHT SIDE 91/./1361 FRONT SIDE 1O66.8[421 CLEARANCE TO COMBUSTIBLE MATERIAL MMIIN. y y BOTTOM 0 1 1� BACK SIDE 25,A 11) LEFT SIDE 152.1 161 RIGHT SIDE 304.E 1[121 121 Note: The view labeled FRONT SIDE 30,.6 "Bottom Side"represents the base as viewed looking TOP 91,,,1361 up from underneath the unit. DOEM ME 4 4YCC4048A-SUB-1 D-E N � �� �l Outline Drawings Figure 2. 4YCC4042-4060 372.82 o (OUTSIDE) 58.19 -' 12-9/321 \ RETURN 322.84 SUPPLY [12-23/321 449.02 [17-11/111 79.50 (OUTSIDE) 13-I/81 449.02 16 [17-111161 [ -15/15/16] (OUTSIDE) BACK DUCT OPENINGS 530.60 • 120-7/81 x x 1402.34 155-7/321 (SURFACE AREA) BACK SIDE Height mm/in Approx.Corner Weight-kg/Ibs Shipping Total Unit Center of Gravity mm/in Model Weight Weight A W1 W2 W3 W4 kg/Ibs kg/Ibs B C 4YCC4042(060) 898.53[35-3/8] 71.2[157] 46.6(103] 34.6[761 53.1[117] 252.2[555] 202.0[4521 470.0[18.5] 731.0[28.8] 4YCC4042(090) 898.53[35-3/8] 71.8[158] 47.2[104] 35.2[78] 53.6[1181 254.5[561] 207.3[4571 470.0[18.5] 731.0[28.8] 4YCC4048(070) 1000.13[39-3/81 71.4[157] 44.6(98] 33.2[73) 53.9[119) 250.3[552] 202.1[448] 433.0[17.0] 743.3[29.3] 4YCC4048(090) 1000.13[39-3/8) 72.0[159] 45.0[99] 1 33.8[75] 1 54.4[120] 252.6[557] 205.4[453] 433.0[17.0] 743.3[29.3] 4YCC4060(090) 1000.13[39-3/8] 77.1[170) 45.8[101] 34.4[76] 58-3[128] 263.1[580] 215.9[476] 433.0[17.0] 743.3[29.3] 4YCC4060(115) 1000.13[39-3/8] 78.0[172] 46.3[102] 34.9[77] 59.0[130) 265.8[586] 218.6[482] 414.0[16.3] 635.0[25.0] 4YCC4048A-SUB-1 D-EN 5 i ' Outline Drawings Figure 3. 4YCC4042-4060 13 0 381 .00 ( 151 ��— ( INSIDE) 318.75 457.20 �� RETURN 112-9/161 [ 181 ' 457.20 ( INSIDE) SUPPLY [ 181 75.41 ( INSIDE) 12-31/321 75.41 — 244.09 12-31/321 381.00 19-5/81 [ 151 ( INSIDE) BOTTOM DUCT OPENINGS 24V ENTRY—\ -Rd ° ° ° ° 359.80 [ 14 5/321 294.02 ° [II-9/161 178.66 ° [7-1/321 ° GAS LINE ENTRY POWER ENTRY 84,96 27.78 DIA. HOLE I FOR 12.70 [ 1121 N.P.T. [ 1-3/321 [3 II/32] GAS CONNECTION 98.66 121.84 [3-7/81 RIGHT SIDE - [5-1/321 6 4YCC4048A-SUB-1 D-E N Indoor Fan Performance Table 1. Horizontal Airflow 4YCC404BA1070A EXTERNAL STATIC PRESSURE(IN.WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CFM 1120 1047 980 914 840 758 674 581 - - - HEAT-LOW WATTS 117 126 135 145 156 168 179 188 - HEAT-HIGH CFM - 1204 1149 1095 1043 989 926 858 798 WATTS - 176 185 195 205 216 227 239 249 COOLING-LOW CFM 1583 1542 1502 1460 1415 1371 1326 1282 1230 1181 - WATTS 302 313 324 332 1 345 353 368 376 394 406 - COOLING-MED CFM 1763 1723 1689 1648 1609 1568 1527 1488 1447 1404 WATTS 414 426 436 448 459 471 483 495 510 524 COOLING-HIGH CFM 1945 1910 1876 1839 1806 1769 1728 1688 1652 1545 WATTS 553 566 577 590 601 613 1 631 643 647 611 4YCC404BA1090A EXTERNAL STATIC PRESSURE(IN.WG) HEAT-LOW CFM 1419 1380 1341 1295 1249 1204 1160 1115 1069 1015 961 WATTS 240 250 259 269 279 291 302 312 323 333 348 HEAT-HIGH CFM 1559 1524 1483 1443 1401 1363 1319 1276 1233 1195 1147 WATTS 313 324 335 346 356 367 379 I 392 403 415 428 COOLING-LOW CFM 1583 1542 1502 1460 1415 1371 1326 1282 1230 1181 - WATTS 302 313 324 332 345 353 368 376 394 406 - CFM 1763 1723 1689 1648 1609 1568 1527 1488 1447 1404 - COOLING-MED WATTS 414 426 436 448 459 471 483 495 510 524 - CFM 1945 1910 1876 1839 1806 1769 1728 1688 1652 1545 - COOLING-HIGH WATTS 553 566 577 5907 601 1 613 631 643 647 611 - Table 2. Down Airflow 4YCC404BA1070A EXTERNAL STATIC PRESSURE(IN.WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 HEAT-LOW CFM 1126 1052 985 918 845 762 677 584 - - - WATTS 117 127 136 146 156 168 180 189 - HEAT-HIGH CFM 1210 1154 1100 1048 994 930 862 802 WATTS 177 186 196 206 217 228 240 250 COOLING-LOW - CFM 1567 1526 1487 1445 1401 1358 1312 1270 1218 1169 - WATTS 308 320 330 339 352 360 375 384 402 413.9 - COOLING-MED CFM 1745 1706 1672 1632 1593 1552 1512 1473 1433 1390 WATTS 422 434 444 457 468 480 493 505 520 534 CFM 1925 1890 1857 1821 1788 1751 1711 1671 1635 1530 - COOLING-HIGH WATTS 564 1 577 589 602 613 625 644 656 660 623 - 4YCC4048A1090A EXTERNAL STATIC PRESSURE(IN.WG) HEAT-LOW CFM 1426 1387 1348 1301 1255 1210 1166 1120 1074 1020 966 WATTS 241 251 260 270 281 292 303 314 325 335 349 HEAT-HIGH CFM 1567 1531 1491 1450 1408 1370 1326 1282 1239 1201 1152 WATTS 315 325 337 347 358 368 381 394 405 417 430 COOLING-LOW CFM 1567 1526 1487 1445 1401 1358 1312 1270 1218 1169 - WATTS 308 320 330 339 352 360 375 384 402 413.9 - COOLING-MED CFM 1745 1706 1672 1632 1593 1552 1512 1473 1433 1390 - WATTS 422 434 444 457 468 480 493 505 520 534 - COOLING-HIGH CFM 1925 1890 1857 1821 1788 1751 1711 1671 1635 1530 - WATTS 564 577 589 602 613 625 644 656 1 660 623 4YCC4048A-SUB-1 D-EN 7 I �: Full Perimeter Roof Mounting Curb Figure 4. 4042 —4060 Models BAYCURB051A Full Perimeter Roof Mounting Curb 15 7/88 56 1/8 3 RETURN AIR 1 1/2 SUPPLY AIR 10 7/8 19 1/2 20 4 3/4 19 1/2 41 7/8 14 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only.These drawings are not intended to be used as a basis to construct, build or modify the i \ items depicted in the drawings.The manufacturer i \ is not responsible for the unauthorized use of these \ drawings and expressly disclaims any liability for damages resulting from such unauthorized use. A 6 i \ RETURN i \ AIR i \ SUPPLY D AIR Ci i ' \ CHANNEL SIDE CHANNEL END WOOD NAILER SERVICE CLEARANCE DIMENSIONS HOLE IN ROOF A B C D WC*/TC* 42.00 36.00 12.00** 24.00 38 7/8 i 53 1 8 DC*/YC* 42.00 36.00 12.00** 36.00 \ **42.00 WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY 8 4YCC4048A-SUB-1 D-EN Optional Equipment — Filter Rack Figure 5. BAYFLTR101 Filter Rack(4024-4036) BAYFLTR201 (4042-4060) (Mounts in Filter/Coil Section) Figure 6. BAYACCDOR1A Hinged Filter Access Door(4024-4036) BAYACCD0R2A(4042-4060) Replaces Filter/Coil Access Panel Note:The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only.These drawings are not intended to be used as a basis to construct,build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 4YCC4048A-SUB-1 D-E N 9 Optional Equipment — Economizer Table 3. BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) HVAC Unit Economizer Unit Application Models �.o�. �.._.._.. Economizer .�.a..��.._..=.�..e.�,.�,�.. rain hood BAYECON101A 4024-036 Outside air lidampers Return air dampers Required filter kit, order Mist separately eliminator r� u BAYECON102A 4042-060 Relief Return damper Duct Roofcurb Table 4. BAYCON200,201A Horizontal Economizer and Rain Hood Economizer A _ B G D ` I Gaskets (2) 1 f Duct E Rain Hood Jr Mixed Air Sensor Economizer Models A B C D E F BAYECON200A 4024-4036 22" 20" 16-7/8" 15-11/16" 11-11/16" 15" BAYECON201A 4042-4060 26" 22-21/32" 19" 17-11/16" 14-11/16" 21-3/8" Note:The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only.These drawings are not intended to be used as a basis to construct,build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 10 4YCC4048A-SUB-1 D-E N Optional Equipment — Outside Air Damper Table 5. BAYOSAH001 and 002A I� Manual Fresh Unit Air Model Application A B C D Models ' AEI \ FULLY BAYOSAH001A 4024-4036 22-7/16" 20-11/16" 12-3/8" 9-3/16" OPEN ,,•C� � f3 All, 1/ FULLV B CLOSED 11 BAYOSAH002A 4042—4060 25-3/16" 20-11/16" 12-3/8" 9-3/16" Table 6. BAYDMPR101 and 102A,25%Motorized Outside Air Damper (Mounts Over Horizontal Return Air Opening) Manual Unit Fresh Air Application A B C D E n Model Models r. �I } BAYDM- PR101A 4024—4036 15-13/16" 11-13/16" 10-1/4" 11-1/2" 12-1/4" C B e BAYDM- PR102A 4042—4060 18-3/16" 15-1/8" 10-1/4" 11-1/2" 12-1/4" ~ D --IN- Note:The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only.These drawings are not intended to be used as a basis to construct,build or modify the items depicted in the drawings.The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability fordamages resulting from such unauthorized use. 4YCC4048A-SUB-1 D-EN 11 I I I I Mechanical Specifications General Constant Torgue,forward-curved,centrifugal wheel in The units shall be horizontal airflow as shipped and a Composite Vortica O Blower housing. Motor shall convertible to downflow. have thermal overload protection and permanently lubricated motor bearings. Motor/blower assembly All units shall be factory assembled,piped,internally isolated from unit with rubber mounts. wired and fully charged with refrigerant. Units shall be certified to UL Standard 1995. Units shall be designed Outdoor Fan to operate at ambient temperatures as high as 115°F. One direct-drive,statically and dynamically balanced Cooling performance shall be rated in accordance with propeller fan shall be used in a draw-through vertical AHRI standards.The YC heating/cooling unit design is discharge configuration. Permanently lubricated certified to ANSI 221.47/CSA 2.3,specifically for weather proof motor shall have built-in thermal outdoor applications using natural gas or propane.All overload protection. units shall be designed for outdoor rooftop or ground System Controls level installation. System controls include condenser fan,evaporator fan Unit Casing and compressor contactors. All components shall be mounted in a weather- Accessories Roof Curb resistant steel cabinet with an enamel finish.Access panels shall be provided for unit controls and indoor The roof curb shall be designed to mate with the unit coil and fans. Indoor air section compartment shall be and provide support and complete weathertight completely insulated with fireproof,permanent, installation when properly installed.Adhesive back odorless fiber material. Knockouts shall be provided for polyurethane sealing strips shall be provided to ensure utility and control connections. Drain connections shall an airtight seal between supply and return openings of be provided to accommodate indoor water runoff. the curb and unit.The roof curb design allows field Compressor fabricated ductwork to be connected directly to the curb.Curb ships knocked down for field assembly,and The compressor shall be hermetically sealed,high includes factory installed wood nailer strips. efficiency scroll compressors. Internal overcurrent and Heating System overtemperature protection,internal pressure relief Gas-Fired Heating Section shall be standard.Other features include centrifugal oil pump,low vibration and noise. Models shall provide completely assembled,wired and piped gas fired heating systems within unit.Design Refrigeration System certified by UL,specifically for outdoor application. All units shall have refrigerant control.Service pressure Threaded gas connection on the unit. tap ports and a refrigerant line filter shall be standard. Electric Ignition System Evaporator Coil(2-4 Ton Models)All aluminum Main burner is lit each time thermostat calls for heat. micro channel,extruded tubes,mechanically bonded to Flame sensor proves flame and keeps the main burner aluminum fins,and factory pressure and leak tested at on.Should a loss of flame occur,the main valve closes 480 —650 psig.All units have TXV to control refrigerant and the spark recurs within 0.8 seconds.When flow. thermostat is satisfied, main burner is extinquished. Condenser Coil Forced Combustion Blower The Spine Fin TM condenser coil shall be continuously Insures flame stability under varying wind conditions. wrapped,corrosion resistant all aluminum with Gives higher combustion efficiency and location minimum brazed joints.This coil is 3/8"OD seamless flexibility. aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand 2.000 pounds of Heat Exchanger pressure per square inch.The outdoor coil provides Stainless steel tubes. Free floating design. low airflow resistance and efficient heat transfer.The Burners coil is protected on all four sides by louvered panels. Indoor Air Fan Stainless steel. Multi-port inshot. 12 4YCC4048A-SUB-1 D-EN i Mechanical Specifications Single Source Power Entry that shall be gravity closing and prohibit entrance of This accessory when used with electric heat accessory outside air on equipment"off"cycle.Economizer shall allow single source power connection to unit and requires BAYRLAY004A relay kit to interface the heater combination.Single source power entry kits economizer to the heat pump. shall have specific matching heater(s). Kit shall include Manual Outside Air Dampers high voltage terminal blocks,fuse blocks and fuses,cut- Rain hood and screen shall be field installed.Suitable to-length interconnecting wiring,and junction box(if for up to 25%outside air. required)to provide power sources with fuse protection as required for both the unit and accessory Start Kit heater. Kit components shall install within the heater Extra compressor starting capacity for single phase cabinet in the heater access section.Single source equipment. branch power circuit shall be protected and wired in Control Options accordance with local codes. Standard Indoor Thermostats Fully Modulating Economizer Two stage heating/cooling or one stage heating/cooling This accessory shall be field installed and be composed thermostats shall be available in either manual or of the following items:0-100%fresh air damper, automatic changeover. damper drive motor,fixed dry bulb enthalpy control, Programmable Electronic Night Setting Thermostat and low voltage pigtails for electrical connections. Solid state enthalpy or differential enthalpy control is Programmable electronic thermostat shall provide optional.Economizer operations shall be controlled by heating setback and cooling setup with 7—day the preset position of the enthalpy control.A programming capability. 1 H/1 C or 2H/2C models barometric relief damper shall be standard with the available. economizer and provide a pressure operated damper coi�_ us Intertek The manufacturer optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, the manufacturer offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information,visit www.IRCO.com. The manufacturer has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2014 Tra n e Supersedes SUB 4048 UBIC-E015 ORIn ersoll Rand Supersedes 4YCC4048A-SUB-1C-EN (February2015) MODEL CA XAD-4-45-GL °"�'"E° nntmct COMBINATION LOUVER WXY ma tit DRAINABLE BLADE. AMCA LICENSED, w Standard Construction: Frame: 4"x.081 (101 mm x 2.1 mm)extruded aluminum(6063-T5). 4 Stationary Blades: .060(1.5 mm)extruded aluminum(6063-T5). 101 mm approximately 4-3/8"(111 mm)on centers. Adjustable Blades: .080(2 mm)extruded aluminum(6063-T5). Blade Angle: 45' Bearings: Permanently lubricated oilite bronze, press fit into frame. I Axles: 3/8"(9.5 mm)square plated steel. Linkage: Plated steel concealed in jamb. ;+ Operator: Wing nut side bracket. Blade Seals: Extruded Vinyl. 7 I Jamb Seals: Flexible stainless steel. + I Screen: Bird screen-3/4"x.050(19 mm x 1.27 mm)flattened +! expanded aluminum in a removable frame on interior of louver. Finish: Mill aluminum. Minimum Section Size: 8"w x 12"h (203 mm x 305 mm) Maximum Section Size: 60"w x 96"h(1524 mm x 2438 mm) o Options: Screens: Insect screen- 18 x 16 mesh aluminum Other: Finish: Prime Coat. 4 3/8„ Baked Enamel. 111 mm I Clear Anodize-204-R1 &215-R1 Integral Color Anodize Kynar 500 Enamel Other: Sill Extensions: Flange: 1-1/2"(38 mm)(front or rear) Channel Frame Other Operator - Notes: Louvers fabricated 1/4"(6.4 mm)under a, opening size unless otherwise noted. 0 0 N T 7 0 imp I LA ] r o 0 X U1-112"(38 mm) I Jamb Visible Sill Flange Mullion Extension Frame Specifications are correct at time of printing.However,as part of our'continuous improvement program,'we reserve the right to make further improvements without notice. Project: Contractor: Deceived Location: Address: T 21 2016 Architect: P.O. Number:Engineer: Date: �AD 14l� 1 NCA MANUFACTURING, INC. 0 1036 SOUTH JUPITER ROAD 0 GARLAND, TEXAS 75042 0 TEL.972-276-5002 FAX 972-276-6747 MODEL CA XAD-4-45-GL COMBINATION LOUVER • DRAINABLE BLADE. AMCA LICENSED. PERFORMANCE DATA Specifications Furnish and install where shown model CA-XAD-4-45-GL louver, manufactured by NCA Manufacturing. Louvers shall be the combination drainable type with a frame depth of 4 inches. Frames and adjustable blade shall be .081 inches thick 6063-T5 extruded aluminum alloy.Stationary blades to be.060 inches thick 6063-T5 extruded aluminum alloy. Blades shall be located on a 45 degree blade angle.Screens shall consist of 3/4"expanded aluminum,with an aluminum frame, mounted to the louver interior, and be removable for cleaning. Louvers shall be finished with Polyurethane Acrylic enamel, Kynar 500, Anodize or other finishes selected by the architect from NCA standard color charts. CA-XAD-4-45-GL FREE AREA IN SQ. FT. Width-Inches 8 12 18 24 30 36 42 48 54 60 12 0.15 0.26 0.41 0.57 0.73 0.89 1.05 1.21 1.37 1.53 18 0.27 0.47 0.76 1.05 1.34 1.63 1.93 2.22 2.51 2.80 24 0.37 0.64 1.04 1.44 1.84 2.24 2.64 3.04 3.44 3.84 30 0.55 0.94 1.52 2.10 2.69 3.27 3.85 4.44 5.02 5.60 36 0.691 1.17 1.90 1 2.63 3.37 4.10 4.83 5.56 6.29 7.02 42 0.791 1.35 2.19 3.03 3.87 4.71 5.56 6.40 7.24 8.08 L 48 0.93 1.60 2.60 3.59 4.59 5.59 6.59 7.58 8.58 9.58 c 54 1.07 1.83 2.96 4.10 5.24 6.38 7.52 8.65 9.79 10.93 60 1.18 2.02 3.28 4.53 5.79 7.05 8.31 9.57 10.82 12.08 2M 66 1.33 2.28 3.69 5.11 6.53 = . 7.95 12.20 13.62 a) 72 1.45 2.47 4.02 5.56 7.10 13.27 14.81 78 1.57 2,69 437 6.04 7.72 14.43 16.11 84 1.72 2.95 4.78 6.62 8.45 15.80 17.64 90 1.79 3.06 4.97 6.88 8.79 16.42 18.33 96 1.97 3.38 5.48 7.59 9.70 18.12 20.23 rn •7 NCA Manufacturing,Inc, o .6 certifies that the Model 0.2E N .5 CA-XAD445-GL louver ' 0,26 T 4 shown herein is licensed 3 .3 to bear the AMCA seal.The < 024 ratings shown are based W e2z -J w z on tests and procedures LL I L6 a performed in accordance with AMCA Publication LL o 0 511 and comply with the a Q Qw requirements of the W n 0.16 XI V IAMCA Certified Ratings °0 0,,4 1 program. o, Q z z 0.12 a02 0 0< The AMCA Certified Seal 0.10 w applies to air performance w .03 - ratings and water W °°R U3 / penetration ratings. 0. 0.06 a02 a 0.04 I 3 002 OERTMID 01 RRTIRGf 000 1 3 4 5 6 7 6 910 20 30 900 1000 1100 1200 IUII�ER VELOCITY THROUGH FREE AREA FPM VELOCITY THROUGH FREE AREA RIR FPM X 100 Water Penetration PRESSURE DROP Water Penetration Data applies to test unit size 48"x 48"only. INTAKE Beginning of Water Penetration is 986 FPM Free Area Velocity. Pressure Drop Data applies to test unit size 48" x 48" only. Performance shown is at standard air density 0.075 lbs./ft'. Performance Data does not include the effects of birdscreen. NCA MANUFACTURING, INC. 0 1036 SOUTH JUPITER ROAD 0 GARLAND,TEXAS 75042 N TEL.972-276-5002 FAX 972-276-6747 . � I' Pagel of 5 Cddlair 9 INDUsrnIES FAN SUBMITTAL COVER SHEET Date: 10/20/2016 To: EVERGREEN STATE S/M ATTN: KEN Address: Phone: Fax: Email: Project: BOYS&GIRLS CLUB Location: ARLINGTON Engineer: EVERGREEN STATE S/M From: Air Tec Co By: Mike Snorsky Address: 85 South Orcas Phone: 206-763-9911 Fax: 206-763-1950 Email: msnorsky@airtecco.com Comments: Received OCT 21 2016 �,ID 10 LO 4- 0 N (D 0) (u Gl O Z � a H U N LL W d V Q a W Hd O 2 m t M a o o m O N co O CV LL N 2 � 0 0 3 = � N o N o a M of U H c � O N _ cu N a) a) LL m Lot L d N LL LL Q U U) o N it CD - °6 LO z CO o LL LQ Z3 O LL v J m Q O Z m W z Z w U O a M c+M O O Z O co W Q d d U O O O a or N O Q H O Q c Im O H w Y Co p U) a a � U O U Q i m 0 Cl) @ D (a 2 f G g C) 75 « k 2 / 2 / 2 » ƒ CO k yy f n 7 w / cn ® � * L f k § k @ / § % $ S cis § 2 U) o m % e » 2 \ ° ® � § -k / / D m CD / kW § % (3j ) § ® ky $ � E / ¢ &> < p e = F- m c E � kk 3 dk �� ¥ 2 2 = 0 3 2 / o — = ® 2 $ e o - _ = 2 — c / �� a) 0 2 G -0 2 / aA \ U, \a) -C y » m § � E S o DtCoCU7 « % § § cn E $ £ � 0 0 W M 0 « 0- CLILwn > m § k ƒ � 0 s I!' TAG: EF-1 Page 4 of 5 Type CRBA Belt Drive Centrifu al Non-overloading aluminum wheel g computer balanced Power Roof Ventilator • Force ventilated motor B DIA. compartment isolated from airstream — Variable pitch motor pulley • Vibration isolators on drive frame • Weatherproof spun aluminum INDUSTRIES housing AMERICAN COOLAIR CORPORATION • NEMA Standard open drip-proof motors Accessories I • Overlapping wheel/inlet Venturi A/D MOTORIZED C • Heavy duty self-aligning pillow- block bearings with cast iron DAMPER(120/1,POSR _-. �= housing INTERNAL MOUNT 1 . 1/2"galvanized mesh birdscreen ACTUATOR • LIL Listed for Standard 705(most PFC1 Roof Curb models) I+ A SQ.I.D. J 2• Dimensions in inches A B C unless otherwise noted L 46 61 3/4 441/4 1 Weight: 591 lbs. Tip Speed: 4,371 fUmin Outlet Velocity: 897 ft/min Qty Fan Data Motor Data Accessories Model No. CFM inWg RPM BHP MHP I RPM Voltage/Ph I Hz JEncl. PFC1 AID 1 CRBA36ND8363 11,550 0.250 450 1.36 2 1 1,750 1208/230/46OV3PHI 60 JOPEN Sones LWA dba dba dba Octave Band Sound Power(LwA) @ 5' @ 10' @ 20' 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 14000 Hz 8000 Hz 12.5 72 61 55 49 84 85 72 67 64 58 54 47 Air Density:0.075 Ibs/ftA3 AMCA Licensed for Sound and QTfKQ 1.00 — 2.00 Air Performance OIRTIAID I Power rating(BHP)does not �IITIIWf Include transmission losses. Bearing losses are Included. / AD Performance ratings do not .,! 07s 1 50 include the effects of JIL appurtenances(accessories). Performance shown is for } Installation Type'A':Free inlet, > Free outlet _E The sound ratings shown are m loudness values In American Coolair Corporation certifies that 0.50 1 00 -' hemispherical sones at 1.5 in(5 the Type CRBA units shown herein are ft.)In a hemispherical free field licensed to bear the AMCA seal.The ri I calculated per AMCA Standard ratings shown are based on tests and 301. procedures performed in accordance with t1 Values shown are for AMCA Publication 211 and AMCA Installation Type'A':Free inlet Publication 311 and comply with the 0. 5 "-------^---�—""'�� � ��� �— 0,50 hemispherical sone levels requirements of the AMCA certified Ratings I Sound ratings apply to sones Program. �" only, 0 D0 p,ee 0 2,500 5,000 7,500 10,60 12,500 15,D00 Volume Flow Rate(CFM) Notes: Project: BOYS&GIRLS CLUB Engineer: EVERGREEN STATE S/M Location: ARLINGTON Contractor: EVERGREEN STATE S/M Submitted By: Date 10/20/2016 Approved By: Date FanSelect 6-July 2016 ver.6.6.0 ., i . � -�� Page 5 of 5 Type PFC1 and PFC2 Roof Curb Dimensions For Fan Models CRBA - CRBCA - CRDA is INDUSTRIES AMERICAN COOLAIR CORPORATION P.O.Box 2300 Jacksonville,Florida 32203 Phone: (904)389-3646 Fax: (904)387-3449•(904)381-7560 E-mail: fans@coolair com Internet: www.coolair.com D SQ. H O.D. � ll 1 5/8 11/2 Thick _ Insulation Wood _ �� PFC1 - 8 Nailer Optional : '< PFC2 - 12 , 1 - Damper Shelf G SQ.* Unit Size D G* H J 06, 08, 10 24 1/2 11 1/4 16 1/2 13 1/4 12, 13, 15 29 1/2 16 1/4 21 1/2 18 1/4 16, 18, 20 36 1/2 23 1/4 28 1/2 25 1/4 24 40 1/2 27 1/4 32 1/2 29 1/4 30 46 1/2 33 1/4 38 1/2 35 1/4 36 52 1/2 29 1/4 44 1/2 41 1/4 44 62 1/2 49 1/4 54 1/2 51 1/4 52 71 1/2 58 1/4 63 1/2 60 1/4 * -The Damper Shelf is an optional accessory. Dimensions in inches i" � �n r� i _e of REZNOR Power Vented, Low Static Axial Fan Unit Heaters for Residential and Commercial lndustrial Use Model UDAP Sizes 30-125 approved for utility applications such as residential garages 4 under CSA International Requirement C 10.96 - U.S. and CR96-0005 - Canada Z N 0 pl: Ml �--- �1A1 'COS.) U�q U45 ; CSA 2.6b ANSI Z83.8b DESCRIPTION Reznor,"V3 Series Model UDAP gas-fired unit heaters are available in 14 sizes ranging from 30.000 to 400,000 BTUH gas input.Sizes 30-125 are approved for residential application.All sizes are approved for commercial/ industrial installations. Model UDAP heaters are designed for 82-83%thermal efficiency and are approved for installation in the United States and Canada by the Canadian Standards Association (CSA). Reznor V3 Series unit heaters have a refreshing new appearance with a glossy white cabinet finish and less visible hardware. Each size cabinet is easily suspended from either 2 or 4 suspension points. Or, an optional hanger kit for Sizes 30-125 allows for ceiling mounting. The low voltage terminal strip on the outside of the cabinet makes connecting control wiring easy with no panels to remove. The addition of a "G"terminal to the strip, along with the new design of the circuit board, allows for fan only operation (without adding relays).All units have a factory installed gas line nipple to the exterior of the cabinet for easy gas service connection. The preeminent new internal feature is the TcoRE2 v heat exchanger and single burner combustion system. Other standard features Include a single-stage gas valve,multi-try direct spark ignition with 100%lockout,presid sure swtch to verify vent flow,resiliently isolated venter motor,venter wheel with improved housing,resilient[R isolated axial fan and motor assembly,and a high temperature limit control.Sizes 30-125 also include a flame rollout safety switch. Operation is controlled through an integrated circuit board. The circuit board monitors heater operation and has LED diagnostic indicator lights to identify abnormalities in control functions. The V3 Series unit heaters are designed to provide all the features you expect in a Reznor heater plus im- proved efficiency,easier installation,and a new look—both inside and out.Look for the unique white unit with no visible front and bottom hardware,deep red louvers,black side handle,and angled corner to know you have a genuine Reznor unit by Thomas&Betts. STANDARD FEATURES • Sizes 30-125 certified for residential heating application • Sizes 30-400 certified for commercial/industrial heating application e 82-83%Thermal efficient— TOP in its classl • 50-60`F Rise range • TccRE2's titanium stabilized aluminized steel heat exchanger • Patented"TcOROS single burner combustion system including a one-piece burner assembly • 115/1/60 Supply voltage • 115 Volt open fan motor with internal overload protection • Transformer for 24-volt controls • Integrated circuit board with diagnostic indicator lights • Multi-try direct spark ignition with 100%lockout • Fan relay(included on the circuit board) . Single-stage natural gas valve(field adjustable for operation to 9,000 ft.elevation—) • Vibration/noise isolated fan and venter motors—designed for low noise operation • 2-pt and 4-pt Suspension—standard on all sizes • External terminal strip for 24-volt wiring . External gas connection • Full fan guard—engineered for safety • Improved cabinet design with less visible hardware and a NEW Reznor appearance OPTIONAL FEATURES - e Single-stage,propane gas valve(field adjustable for operation to 9.000 ft.elevation—) FACTORY INSTALLED • Two-stage natural gas or propane gas valve-Sizes 60-400 Received • 409 or 316 Stainless steel heat exchangers • 208 or 230 Single phase voltage s1 7 e Totally enclosed fan motor(Sizes 30-250, 115V only) OCT 2 1 20 Ib • Common venting with other gravity vented Category I appliance(s) (Sizes 30-100) P10 6l "'U.S.Patent No.6,889.686 1 Pn P7-(:-I IH Afarcinn H1 Pnna A �����.� r /� OPTIONAL FEATURES - • Ve' )p Page Number of FIELD INSTALLED • Thermostat • Thermostat guard with locking cover • Vertical louvers-new design • Downturn nozzle kits-new design • Gas conversion kits(natural and propane) a Master/Slave controls for zoning up to six units • Ceiling suspension kit-Sizes 30-125 • Hanger kits for 1"pipe . Stepdown transformer(for 230/3 and 460/3 supply voltage) • Manual shutoff valves "Gas pressure change required for installations above 6,000 ft. TECHNICAL DATA Model UDAP Size 30 45 60 75 100 126 150 175 1 200 225 250 300 350 400 BTUH 30.000 45.000 60.000 75,000 105,000 120,000 150.000 175,000 200,000 225,000 250,000 300.000 350,000 400,000 Input Heating Capacity kW/h 88 13.2 17.6 22.0 30.8 35.2 43.9 51.2 58.6 65.9 73.2 87.8 102.5 117.1 Thermal Efficiency(%) 82 83 83 83 83 63 83 83 83 83 83 83 83 83 Output Heating BTUH 24,600 37,350 49,800 62.250 87.150 99,600 124.500 145,250 166,000 186,750 207,500 249,000 290,500 332.000 Capacity^ kW/h 7.2 11.0 1 14.6 18.3 1 25.6 29.2 36.4 42.5 48.6 54.7 60.8 1 72.9 85.1 97.2 Gas Connection Natural 112 1/2 1/2 112 112 112 1/2 1/2 1/2 3/4 314 3/4 3/4 3A (inches)6 Propane 1/2 1/2 1/2 1/2 1/2 1/2 1/2 112 1/2 3/4 3/4 3/4 3/4 3/4 Vent Connection Size c(inches 4 4 4 4 4 4 5 5 5 5 5 6 6 6 diameter Control Amps 24 volt 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Full Load Amps 115 volt 1.9 2.4 2.4 3.3 3.9 5.1 1 3.8 3.8 4.6 7.5 7.5 11.0 11.0 11.0 Maximum Over Current Protection 15 15 15 15 15 15 15 15 15 15 15 20 115 20 1 20 Normal Power Consumption 109 155 155 217 276 354 392 392 491 747 747 1086 1086 1086 watts Discharge Air Temperature Rise 50 55 60 60 60 60 60 60 60 60 60 60 60 60 °F Air Volume CFM 456 629 769 961 1345 1537 1921 2242 2562 2882 3202 3843 4483 5123 M'/minute 12.9 17.8 21.B 27.5 36.7 45.9 54.4 63.5 72.5 81.6 90.7 108,8 126.9 145.1 Discharge Air Opening ft2 0.96 0.96 1.25 1.25 2.01 2.01 2.56 2.56 2.56 3.51 3.51 4.79 4.79 4.79 Area M2 0.09 0.09 0.12 0.12 0.19 0,19 0.24 0.24 0.24 0.33 0.33 0.45 0.45 0.45 Output Velocity FPM 475 656 616 770 668 763 752 877 1003 820 1 911 802 936 1069 M/minute 145 1 200 188 238 196 245 1 229 267 306 250 278 244 285 326 O en 0.02 0.03 0.03 0.06 1/30 1/20 1/6 1/6 1/6 1/4 1/4 1/2 1/2 1/2 Fan Motor HP a Enclosed 0.06 0.06 0.06 0.06 1/4 1/4 1/4 114 1/4 114 1/4 1/2 1/2 112 Fan Motor RPM 1550 1550 1550 1550 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 Fan Diameter(inches) 10 10 12 12 16 16 18 18 18 20 20 24 24 24 Sound Level dB5 @ 40 40 40 49 54 55 51 52 53 56 56 59 61 62 Approximate Net Ibs 54 59 67 72 96 101 172 187 187 203 215 269 294 306 Weight kg 24 27 30 1 33 44 _ 46 78 85 85 92 98 122 133 139 Approximate Ship Ibs 61 66 74 79 118 123 204 219 219 245 257 321 346 358 Weight k 27 30 33 36 54 56 93 1 100 100 111 117 146 157 163 A GSA rating for altitudes to 2000 ft 6 Size shown is for gas connection to a single stage gas valve,not supply line size. c Smaller or larger vent pipe diameters may be allowed.refer to the Venting Installation Manual,Form I-V-PV.If vent diameter is different from vent connection,reducer/enlargers will be field-required. °MODP=2.25 x(largest motor FLA)+smallest motor FLA.Answer is rounded to the nearest commercially available circuit breaker. ff All other information in this table is based on a healer equipped with a standard 115 volt open fan motor. For installations where dirt,dust,and other air borne contamination is present in the indoor environment,it is recommended to use separated combustion units(Model UDAS).These models use air from outside the space for combustion.This will help reduce the build up of contaminates on the burner which would affect the combus- tion process.Refer to the installation manuals for recommended frequency of maintenance and cleaning. Form RZ-C-UH(Version H)Page 9 i w ,. 'l _� ., i i '" .or, CVMMERCIAL MECF.ANICAL • PERMIT APPLICATION y�ll� r�0 Department of Community& Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF CONSTRUCTION DRAWINGS AND ALL OTHER INFORMATION OUTLINED IN THE MECHANICAL PERMIT SUBMITTAL REQUIREMENTS, IF APPLICABLE. Type of Permit: 7 New Installation 1� ❑ Replacement Alteration Project Address: f �/� ,5q� /� r� Parcel#: Project Description: Valuation: Owner: 1S F,/dL�S �1�.� ek- %y �1 Phone#: Address: City: State: Zip: Email Address: Contact Person: l`I.) (.-L) _ Phone #: Address: 2-1 W LCt-tct< City: t✓UL--71I_ State: Zip: -Orzo/ Email Address: Contractor Name: LU��'�"/ZL Phone#: �11M Contractor Address: Z I Z �/I-C( _ _City: LLt--TZ State:LdA. Zip: Email: k-PM Contact Person: C_S�Cb Contractor License Number: �yCIZG'_SS�ZZnT Expiration: Please indicate type of number of appliances: FURNACE CONDENSING UNIT GAS PIPING OUTLET BOILER HEAT PUMP(multi-split) UNIT HEATER �- CHILLER HEAT PUMP(mini-split) PAINT BOOTH COOLER HEAT PUMP(other) TYPE I HOOD AC(air cooled) HEAT REJECTION EQUIP _ TYPE II HOOD AC(water cooled) VENTILATION SYSTEM AST AC(evaporator) PACKAGED UNIT �� UST AC(VRF) DRYER OTHER I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in nce with th s,rules and regulation of the State of Washington. Applicants Signature: Date _Z�--1'6 Applicants Printed Name: Received FOR STAFF USE ONLY ��- OCT 24 2016 Permit# t Amount Received Receipt# Date Received 6116LP Page 1 of 1 1 itkT�(Z� fCc l�o � F��w�-cam 2 s vQ PG% 1 p . o 0 t/G-tc� 2�5- • �o Permit Information Date 10/21/2016 Permit Number 1184 Project Name Boys and Girls Club Applicant Name Everegreen State Heat and A/C Applicant Address 2120 Pacific Ave City, State,Zip Everett,WA 98201 Contact Ken Salo Phone 425-252-3114 Email ken@essmwa.com Permit Type Commercial Mechanical Site Address 18513 59th Avenue NE Valuation 40000.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 0 Proposed Use HVAC installation for commercial addition Assigned To Property Information Owner Information Parcel#:31052200103100 ARLINGTON CITY OF ARLINGTON CITY OF 18204 59TH DRIVE NE 18513 59TH AVE NE ARLINGTON,WA 98223 Review Date Type Description I Tar et Date Completed Date Assigned To Status 10/21/2016 -Iommercial Mechanical 10/28/2016 IlKevin Olander Iln Review Uploaded Files Upload File Date File Uploaded B 10/21/2016 12:49:20 PM 11184 Application pdf Foster,Kristin x 10/21/2016 12:43:46 PM 11184_Specs.pdf IFoster.Kristin Fsr Permit#: 1184 Permit Date: 10/21/16 Permit Type: COMMERCIAL MECHANICAL Project Name: Arlington Boys and Girls Club Applicant Name: Everegreen State Heat and A/C Applicant Address: 2120 Pacific Ave Applicant, City, State, Zip: Everett,WA 98201 Contact: Ken Salo Phone: 425-252-3114 Email: ken@essmwa.com Scope of Work: HVAC installation for commercial addition Valuation: 40000.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 10/31/2016 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 31052200103100 18513 59TH AVE NE ARLINGTON CITY 431 Airports& OF Flying Fields Contractors Contractor Primary Contact Phone Address Contractor Type License License# EVERGREEN STATE Mark Payne 425-252-3114 2120 Pacific Ave CONSTRUCTION COA 601-724-357 HEAT&A/C CONTRACTOR EVERGREEN STATE Mark Payne 425-252-3114 2120 Pacific Ave CONSTRUCTION Labor&EVERGSS0220T HEAT&A/C CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 12/21/2016 R09.GAS PIPING Gas piping to rooftop unit 12/21/2016 BUILDING Approved ROUGH-IN complete.KO 12/21/16 10/28/2016 R09.GAS PIPING Inspected main line from 10/28/2016 BUILDING Approved ROUGH-IN meter to first"T"KO. Plan Reviews Date Review Type Description Assigned To Review Status 10/21/2016 COMMERCIAL BUILDING MECHANICAL Fees Fee Description Notes Amount Forced Air Heat fee per Btu $25.00 Gas Piping/Units Enter#of units $10.00 Mechanical Fee(Enter Fixture Fee) $100.00 Mechanical Base Permit Fee $25.00 Mechanical Commercial Plan Review Table 4-1 $400.00 Vents $25.00 Total $585.00 Attached Letters Date Letter Description 10/31/2016 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 12/20/2016 RUSSELL KIMBALL 62776723 cc $585.00 Outstanding Balance $0.00 Uploaded Files Date File Name 10/21/2016 1906479-1184 Application.pdf 10/21/2016 1906472-1184 Specs.pdf O _ 1r C3_ M Lu p a' c a � > 10 loow LLJ o a n a g V P, Np ctt � LLB 0,y� LL. E+m tam Y o a jMl_M < Y N N G •C O W Q/ O H N.ai V•i� t« goo a 12 E — a E v �u25 m'm E v�r341a nn n 9 LL Xx o.,moNf�m3 E a3ei�z°3�� F°- n .W o ti 'w 01 0 r z r i a r� _ -----_.__.p. I 'X'' N t� Sul 4`L