19324 46th Ave Ne_BLD837_2026
BUILDING INSPECTION REPORT — MECHANICAL (RESIDENTIAL) Permit No. 837 Address: 19324 46th Ave Contractor: CM Heating Inc Owner: BRUCE, GLORIA Date: 12/22/2015 ® APPROVAL ❑ PARTIAL APPROVAL ❑ CORRECTION ❑ OTHER APPLIANCE: Gas Furnace CO DETECTOR: © HEAT PUMP/AC UNIT: ❑ GAS PIPING: © DISCONNECT: ❑ DRIP LEG: ® SEISMIC: VENTING: ® 3" PAD: ❑ ACCESS: ® INSULATION/PROTECTION: ❑ SHUT-OFF VALVE: Fx DUCTS: N/A L&I: Yes Date: 12/22/2015 Inspector: Kevin Olander 11/13/2015 IWORQ Systems Inc. - CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address: 19324 46th Ave Permit#: 837 Parcel#:00928200008300 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name: BRUCE,GLORIA Name:CM Heating Inc Name: CM Heating Inc Address: 19324 46TH AVE Address:1415 Broadway Address: 1415 Broadway City, State Zip: ARLINGTON, WA 98223 City, State Zip: Everett,WA 98201 City, State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City, State,Zip: City, State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: STORIES: CONST. TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI I O/IRCI IO. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. A,X/j V,4 D // /3 /57 Signature Print Name Date V ased By bate CONDITIONS Model #R801 SA050314MSA - AFUE 80% - Duct testing is required per R101.4.3.1 THIS PERMIT AUTHORIZS ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/13/2015 Furnace $25.00 11/13/2015 Mechanical Permit Base Fee $25.00 Total Due: $50.00 Total Payment: $0.00 Balance Due: $50.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon http://www.iworq.neUiworq/perm i UpopupPerm itEditLetterPri nt.asp?si d=LFKGQJAN KQN H KC KFKJ PLIJ BLC 0605&perm i tl etteri d=553196 1/1 BUILDING INSPECTION REPORT— MECHANICAL (RESIDENTIAL) Permit No. 837 Address: 19324 46th Ave Contractor: CM Heating Inc Owner: BRUCE, GLORIA Date: 12/22/2015 X APPROVAL ❑ PARTIAL APPROVAL ❑ CORRECTION ❑ OTHER APPLIANCE: Gas Furnace CO DETECTOR: ® HEAT PUMP/AC UNIT: ❑ GAS PIPING: M DISCONNECT: ❑ DRIP LEG: M SEISMIC: VENTING: M 3" PAD: ❑ ACCESS: ® INSULATION/PROTECTION: ❑ SHUT-OFF VALVE: DUCTS: N/A L&I: Yes Date: 12/22/2015 Inspector: Kevin Olander 1 111 3/201 5 IWORQ Systems Inc. 1 CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address: 19324 46th Ave Permit#: 837 Parcel#: 00928200008300 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name: BRUCE,GLORIA Name:CM Heating Inc Name:CM Heating Inc Address: 19324 46TH AVE Address:1415 Broadway Address: 1415 Broadway City, State Zip: ARLINGTON, WA 98223 City,State Zip: Everett,WA 98201 City,State Zip:Everett, WA 99201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City, State, Zip: City,State,Zip. Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: STORIES: CONST. TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASIIINGTON RELATING TO WORYCMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS-IHER DEPUTY AND ALL FEES ARE PAID, IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION 11AS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCt 10/IRCI l0. SALES TAX NOTICE: Sales lax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return Form and coded City of Arlington#3101. Z-4-3,Xfj 9&0 llLI 3 /� Signature Print Name Date • ascd By bate CONDITIONS Model #R801 SA0503 l4MSA - AFUE 80% - Duct testing is required per RI O 1.4.3.1 THIS PERMIT AUTVIORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON,1*111:PUBLIC DOMAIN(CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.)WILL REQUIRE SEPARATE PERMISSION, PERMIT FEES Date Description Fee Amount 11/13/2015 Furnace $25.00 11/13/2015 Mechanical Permit Base Fee $25.00 Total Due: $50.00 Total Payment: $0.00 Balance Due: $50.00 CALL FOR INSPECTIONS BUILDING(360) 403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon http://www,iworq.neUi worq/perm it/popupPerm i tEdi tLetterPri nLasp?si d=LFKGQJAN KQN H KC KFKJ PLI J BLC0605&perm i tl etteri d=553196 1/1 R 11/13/2015 IWORQ Systems Inc. CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address: 19324 46th Ave Permit#: 837 Parcel#: 00928200008300 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name: BRUCE,GLORIA Name:CM Heating Inc Name:CM Heating Inc Address: 19324 46TH AVE Address:1415 Broadway Address: 1415 Broadway City, State Zip: ARLINGTON, WA 98223 City, State Zip: Everett, WA 98201 City, State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City, State,Zip: City, State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: STORIES: CONST. TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1 IO/IRC1 IO. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 1111-3k57 Signature Print Name Date VI ased By bate CONDITIONS Model #R801 SA050314MSA - AFUE 80% - Duct testing is required per RI O 1.4.3.1 THIS PERMIT AUTHORIZS ONLY THE WORK NOTED. TFIIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/13/2015 Furnace $25.00 11/13/2015 Mechanical Permit Base Fee $25.00 Total Due: $50.00 Total Payment: $0.00 Balance Due: $50.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon http://www.iworq.net/iworq/perm it/popupPerm i tEdi tLetterPri nt.asp?sid=LFKGQJAN KQN H KC KFKJ PLIJ BLC0605&perm itl etterid=553196 1/1 --�-' RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington,WA 98223• Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:19324 46TH AVE NE Project Description: INSTALL GAS FURNACE Owner: GLORIA BRUCE Address: 19324 46TH AVE NE City: ARLINGTON State-.WA Zip Code: 98223 Phone: 360-213-5394 Email:MEREDITH@CMHEATING.COM Applicant: CM HEATING Address: 1415 BROADWAY City: EVERETT State:WA Zip Code: 98201 Phone: 425-259-0550 Email: MEREDITH@CMHEATING.COM CONTRACTOR INFORMATION Contractor Name:CM HEATING Address: 1415 BROADWAY City: EVERETT State:WA Zip Code: 98201 License Number:CMHEAMH877DN Expiration: 5/17 Phone:425-259-0550 Email:MEREDITH@CMHEATING.COM STAFF USE ONLY Received Permit #: bw �j�l Accepted by: i Date: NOV 12 2015 i �� RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington•18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model # R801 SA050314MSA AFUE 80 ❑j Heat Pump Model # _ AFUE HSPE ❑, AC Unit Model # SEER ❑ Freestanding Stove ❑i Fire Place Insert ❑ Outdoor BBO ❑ Gas Piping 0i Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: ❑ Pipe Material: Pipe Size: Distance From Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: �j � '� '<< «ter . _ Date: 11/12/2015 Applicant Printed Name: Meredith Gilbert 1 hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. I Air Gas Furnaces ' a R801S(DF)Series The new degree of comfort:" Rheem Classic®Series Downflow Gas Furnace R801 S (Downflow) Series 80%A.F.U.E.t Input Rates 50-150 kBTU 1-A.FU.E.(Annual Fuel Utilization Efficiency)calculated in accordance with Department of Energy test procedures • 80% residential Gas Furnace CSA certified • Low profile 34" cabinet ideal for space constrained • PlustJne'" Diagnostics — 7 Segment LED all units installations • Integrated Control board features dip switches for easy • PlusOne TM Ignition System—DSI for reliability and longevity system set up • Heat exchanger is removable for improved serviceability. . QR code for quick access to product information from your Aluminized steel construction provides maximum corrosion smart phone or tablet resistance and thermal fatigue reliability. Received NOV 12 2015 COMFORTINTEGRATED HOME FORM NO.G11-547 REV.1 i Air an:e of Cu-ve.its �i R801S(DF)Series TABLE OF CONTENTS Standard&Optional Equipment ......................................................................3 Model Features/Physical Data&Specifications..................................................4 Model Number Identification............................................................................5 DimensionalData............................................................................................6 Blower Performance Data................................................................................7 Accessories....................................................................................................6 LimitedWarranty ............................................................................................9 COMFORT0 — INTEGRATED HOME Standard&Optional Equipment a Air R801S(DF)Series Il�lllllfi� �;, i HEAT EXCHANGER INTEGRATED FURNACE CONTROL DRAFT INDUCER MOTOR DIRECT SPARK IGNITOR WITH REMOTE SENSE IN-SHOT BURNERS STANDARD EQUIPMENT OPTIONAL EQUIPMENT Completely assembled and wired; induced draft;pressure NOTE:Furnace is not listed for use with fuels other than switch;redundant main gas control; blower compartment door natural or L.P.(propane)gas. safety switch;solid state time on/time off blower control; limit The complete terms of limited and other warranties are control; manual shut-off valve,pressure regulator for natural available at our sales office,or through local installer. and L.P.(propane)gas;transformer;direct drive multi-speed blower motor. Furnaces are equipped with cooling/heating All models can be converted by a qualified Rheem distributor relay and transformer(40VA)ready for air conditioning or local service dealer to use L.P.(propane)gas without applications.(Please note:a thermostat is not included as changing burners. Factory approved kits must be used to standard equipment.) Flame sensor diagnostics;on-board convert from natural to L.P.(propane)gas and may be ordered twinning;fused-protection(secondary),3rd speed option for as optional accessories from a Rheem parts distributor. continuous fan;common heat/cool terminal. For L.P.(propane)operation,refer to Conversion Kit Index Form. NOTE:For natural and L.P.(propane)gas models,direct spark ignition is 100% lockout type. WARNING FURNACETHIS 1T APPROVED 1' RECOMMENDED 1' USE IN MOBILEHOMES • COMFORT i 1 Model Features/Physical Data&Specifications a Air R801S(DF)Series Model Features • 80% residential Gas Furnace CSA certified • Low profile 34" cabinet ideal for space constrained • PlusOne- Diagnostics - 7 Segment LED all units installations • PlusOne-Ignition System-DSI for reliability and longevity • Blower shelf design-serviceable in all furnace orientations • Integrated Controls board features dip switches for easy • Heat exchanger is removable for improved serviceability. system set up Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability. • QR code for quick access to product information from your smart phone or tablet Physical Data and Specifications U.S.and Canadian Models MODEL NUMBERS R801SA R801SA R801SA R801SA R801SA R801SA I R801SA R801SA R801S(DOWNFLOW) 050314Z*A 075317Z*A 075417Z*A 100317Z*A 100421Z*A 100521Z*A I 125524Z*A 150524Z*A Input-BTU/Hr[kW]2 50,000[15] 175,000 [22] 75,000 [221 100,000[29.3] 100,000[29.3] 100,000[29.31 125,000[36.6] 150,000 [44] Heating Capacity BTU/Hr[kW]O 41,000(12] 60,500 [18] 60,500 [18] 80,000 [23] 80,000 [23] 81,000 [241 99,000 [29] 120,000 [35] High Altitude Input[kW] 45,000[13] 67,500[19.81 67,500[19.8] 90,000[26.4] 90,000[26.41 90,000[26.41 112,500 [33] 135,000[39.6] High Altitude Output 36,500[10.7] 54,000[15.81 54,000[15.8] 72,000[21.1] 72,000[21.1] 72,500[21.21 89,000[26.1] 107,500[31.5] Capacity[kW] Heat Ext.Static Pressure[kPa] .10[.025] .12[.029] .12[.029] .15[.037] .15[.037] .15[.037] .20[.05] .20[.05] Blower(D x W)[mm] 11 x 6 11 x 6 11 x 7 11 x 7=10*AM 11 x 10 11 x 10 11 x 10 11 x 10 [279 x 1521 [279 x 152] [279 x 1781 [279 x 1781 [279 x 254] [279 x 254] [279 x 254] [279 x 254] Motor H.P.[W]-Speeds[W1- 1/2-4-PSC 1/2-3-PSC 3/4-3-PSC 1/2-3-PSC 1/2-3-PSC 3/4-3-PSC 3/4-3-PSC 3/4-3-PSC PSC Type [373] [373] [559] [373] [373] [559] [5591 [559] Motor Full Load Amps 6.8 5.8 9.5 7.1 7.9 9.5 9.5 9.5 Heating Speed LOW MEDIUM LOW IVIED IVIED LOW LOW LOW Cooling Speed HIGH HIGH HIGH HIGH HIGH HIGH HIGH HIGH Cooling CFM Q.5"[kPa]E.S.P, 1200 1200 1600 1200 2000 2000 2000 2000 (Nominal)[L/s] [566] [566] [755] [566] [9441 [944] [944] [944] Rated E.S.P.(In.W.C.)[kPa] 0.5[.121 0.5[.12] 1 0.5[.12] 0.5[.12] 0.5[.12] 0.5[.12] 0.5[.12] 0.5[.12] Temperature Rise Range°F 25-55 30-60 25-55 45-75 40-70 40-70 40-70 50-80 [°C] [13.9-30.61 [16.7-33.3] [13.9-30.6] [25-41.7] [22.2-38.91 [22.2-38.91 [22.2-38.91 [27.8-44.41 Max.Outlet Air Temp.°F 155 165 155 190 190 170 180 170 [°C] [68.3] [73.9] [68.3] [87.81 [87.8] [76.7] [82.2] [76.71 Approx.Shipping Weight(Lbs.) 85 105 105 115 120 120 140 150 [kg] [38.6] [47.6] [47.6] [52.21 [54.4] [54.4] [63.5] [68.01 AFUE-Electric Ignition Models(D 80% 80% 1 80% 80% 80% 80% 80% 80% NOTES:All models are 115V,60HZ,10.Gas connection size for all models is 1/2"N.P.T. O In accordance with D.O.E,test procedures. O See Conversion Kit Index Form for high altitude Berate in U.S.applications. [ ]Designates Metric Conversions INTEGRATED • • •- i Air Model Number Identification 0 11601S(DF)Series Model Number Identification—Downflow Models R 90 1 S A 075 4 17 Z S A Rheem 80= 1 =Single Stage S=Standard Design Series Input 3=Up to Cabinet Z=Down X=Low NOX Revision- 80%AFUE PSC A=1 st Design BTU/HR[kW] 3 Ton Width and Zero S=Standard Marketing 050= 50,000[15] 4=Up to 14=14" Clearance (A—First Time 075= 75,000[22] 4 Ton 17=17.5" Downflow Release) 100=100 000[29] 5=Up to 21=21" 125=125:000[37] 5 Ton 24=24.5" 150=150,000[44] [ ]Designates Metric Conversions • COMFORT i Dimensional Uat:1 Air R801S(DF)Series Downflow Dimensions 7116" TOP BOTTOM Ill mm] RETURN SUPPLY 193/4" P41/2" AIR AIR [502 mm] [622 mm] r?:7NI L H — C E 281h6"[713 mm] A [19 mm] R.A. 201/a" 6!e" B 5/a"[16 mm] D 511 mm] 618" [16 mm] I �[ �I[16 mm] r— 314' 265/8" [19 mm] 1676 mm] 265/9" 1w,DIA.[13 mm] [676 mm] 1 716 DIA LOW VOLTAGE [22 mm] ELECTRICAL " CONNECTION 1864 mm] (HIGH VOLTAGE) 23�V•• O O 2331a" 261ahe" [594 mm] [594 mm] 1681 mm] tea, mm] I II I 247/16" 203/a" [621 mm] [51B mm] GAS CONNECTION 63/16" 63116" 13/e"DIA. (157 mm] �— [157 mm] [35 mm] LEFT SIDE FRONT RIGHT SIDE Dimensions and Clearance to Combustible Material (inches) [mm] MODEL REDUCED CLEARANCES(IN.)[mm] R801S A B C D E (DOWNFLOW) LEFT RIGHT BACK TOP FRONT VENT SHIP.WGTS. SERIES SIDE SIDE (LBS.)[kg] 050 14 [356] 1227/32[326] 103/8[264] D 131/3[333] 0 4 2 0 1 [251 3[761 6[1521 33 85[38.61 075 171/2[445] 1611/32[415] 121/8[308] D 165/8[422] 0 32 0 1 [251 3[761 6[1521 OO 105[47.61 100317 171/2[445] 1611/32[415] 121/3[308] D 165/8[422] 0 32 0 1 [251 3[761 6[1521 03 115[52.21 100421 21 [533] 1927/32[5041 137/8[352] D 201/8[5111 0 0 0 1 [251 3[761 6[1521 03 120[54.41 100521 125 241/2[622] 2311/32[593] 155/3[397] ) 235/8[600] 0 0 0 1 [251 3[761 6[1521 03 140[63.51 150 241/2[622] 2311/32[593] 155/8[397] D 235/8[6001 0 0 0 1 [251 3[761 6[1521 03 150 [681 NOTES: 11 May require a 3"[76 mm]to 4"[102 mm]or 3"[76 mm]to 5"[127 mm]adapter. O May be 0"[0 mm]with type B vent. O May be 1"[25 mm]with type B vent. Furnaces must be vented in accordance with the National Fuel Gas Code,ANSI Z223.1 and in accordance with local codes. ( ]Designates Metric Conversions INTEGRATED • • •- .� I Blower Perfor rai:ce Data Air R801S(DF)Series Blower Performance Data—Downf low Models MODEL BLOWER MOTOR CFM [L/s]AIR DELIVERY R801S BLOWER EXTERNAL STATIC PRESSURE INCHES [kPa]WATER COLUMN (DOWNFLOW) SIZE H.P. SPEED SERIES [mm] [Wl .1[.021 .2[.051 .3[.071 .4[.101 .5[.121 .6[.151 .7[.171 LOW 735[347] 715 [3371 690 [3261 660 [3111 635 [3001 605 [2861 575[2711 050 11 x 6 1/2 MED-LO 1025[4841 1015 [4791 995 [4701 975 [4601 955 [4511 930 [4391 905[4271 [279 x 1521 [373] MED-HI 1185[559] 1165 [5501 1150 [5431 1130 [533] 1100 [5191 1075 [5071 1040[4911 HIGH 1345[635] 1330 [628] 1310 [618] 1295 [611] 1265 (597] 1235 [583] 1205[569] LOW 1104[5291 1081 [5101 1050 [4961 1025 [484] 999 [471] 971 [4581 940[444] 075317 [279 x 1521 [373] MED 1284[6061 1269 [5991 1236 [583] 1206 [5691 1179 [5561 1139 [5381 1102[5201 HIGH 1478[698 1 1438 [6791 1397 [6591 1362 [6431 1392 [6571 1282 [6051 1242[5861 11 LOW 1210[571] 1205 [5691 1195 [5641 1180 [557] 1165 [5501 1155 [5451 1130[533] 075417 [279 x 178] [3 3] MED 1580[7461 1560 [7361 1550 [7321 1530 [7221 1495 [7061 1465 [6911 1430[6751 HIGH 1915[9041 1880 [8871 1825 [8611 1790 [845] 1 1740 [821] 1675 [791] 1600[755] 11 1/2 LOW 1070[5051 1055 [498] 1040 [4911 1010 [4771 980 [4631 945 [4461 905[427] 100317 [279 x 178] [3731 MED 1240[585] 1210 [5711 1190 [562] 1165 [5501 1135 [536] 1095 [5171 1055[498] HIGH 1 1420[670] 1395 [658] 1370 [647] 1340 [632] 1305 [616] 1265 j5971 1220[576] 10 1/2 LOW 1303[6151 1304 (6151 1280 [6041 1250 [5901 1222 [5771 1188 [557] 1160[547] 100421 [279 x 254] [373] MED 1697[8011 1674 [7901 1655 [7811 1638 [7731 1621 [7651 1581 [746] 1542[7281 HIGH 2O78[9811 2068 [9761 2037 [9611 2010 [9491 1988 [9381 1938 [9151 1898[8961 lIX10 3/4 LOW 1690[7981 1670 [7881 1655 [7811 1615 [7621 1585 [7481 1565 [7391 1525[7201 100521 [279 x 2541 [559] MED — 2085 [9841 2055 (9701 2005 [9461 1970 [9301 1945 [9181 1880[887] HIGH — 2410[1137] 2355[11111 2305[1088] 1 2240[1057] 2165[10221 2100[9911 LOW — 1690 [798] 1660 [7831 1635 [7721 1580 [746] 1535 [7241 1480[698] 125524 [279 x 254] [559] MED — 2090 [9861 2035 [9601 1985 [937] 1930 [911] 1850 (8731 1785[8421 HIGH — 2395[11301 2335[1102] 2260[10671 2185[1031] 2080 [9821 1965[9271 10 3/4 LOW 1675[7911 1650 [7791 1620 [7651 1570 [7411 1545 [7291 1485 [7011 1425[6731 150524 [279 x 254] [559] MED 2105[9931 2075 [9791 2035 [9601 1990 [9391 1955 [9231 1900 [8971 1815[8571 HIGH — — — — — — — NOTES:Recommended blower speeds are in bold. [ ]Designates Metric Conversions '_0 INTEGRATED . COMFORT Accessories Air R801S(DF)Series DOWNFLOW ACCESSORIES DOWNFLOW WARNING:Unit design is certified for installation on GXGP-F03 non-combustible floor.A special factory supplied combustible PARALLEL FURNACE KITS—are for parallel operation requirements. floor sub-base is required when installing on a combustible floor.Failure to install the sub-base may result in fire,property damage and personal injury. RXGF-CC* FILTER RACK—Downflow top return mount.Requires(2)14 x 20 filters. COMBUSTIBLE FLOOR BASE DIMENSIONS NOTE:Filter racks are shipped without filters. COMBUSTIBLE USE WITH A B C *Filters available through PROSTOCK®. FLOOR BASE FURNACE SIZES IN.[mm] IN.[mm] IN.[mm] RXGC-B14 801S050 141/2[368] 131/4[337] 11114[286] RXGC-B17 801S075,801SA100317 18 [457] 163/4[425] 143/4[451] RXGF-DB* RXGC-B21 801 SA100421. 211/2[546] 201/4[514] 181/4[464] Each order contains(1)one box of 10 filter racks supplied without filters. 801SA100521 RXGC-824 801S125,801S150 25 [635] 233/4[603] 213/4[552] *Filters available through PROSTOCKO. FOR HIGH ALTITUDES: (495 mMI.--.i HIGH ALTITUDE OPTION CODE:U.S.— __ None required for high altitudes. T. HIGH ALTITUDE CONVERSION KITS:U.S.— c None required for high altitudes. 80+HIGH ALTITUDE INSTRUCTIONS V . ,,,,�,� _ Caution:Always follow National Fuel Gas Code(NFGC)guidelines --[164 mm] [ : when converting for high altitudes. —[7213mm] e High altitude option codes are not required for these models. n However,the burner orifice size needs to be recalculated and verified �7T� '%`•• 1-1n mm]FIBERGLASS at elevations above 2000 ft.See Installation Instructions for more �• 7" � ' 3 LB.[1.4 kg]DENSITY (1tl2 mm1 IMMMI! I FIBERGLASS information. (51 mm] 2" 3 LB.(1-4 kg]DENSITY Fl.00R +PLENUM OR --------•---- - -- 3"(76 mm1 DUCTWORK [ ]Designates Metric Conversions zt l 1646 mm] NOTE:FLOOR OPENING 211 (546 mm]x B MAX PLENUM SIZE 191Iz"[495 mm]x C INTEGRATED HOME COMFORT i r Limited Warranty Air R801S(DF)Series GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product Heat Exchanger ......................................Twenty(20)Years which fails in normal use and service within the applicable Conditional Parts(Registration Required)........Ten(10)Years period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions,contact your local contractor or the Manufacturer for a copy of the product warranty certificate. '-5 INTEGRATED • • •- I Gas Furnaces Air R801S(DF)Series / 1 1 The new degree of comfort- Rheem Classic'Series Downflow Gas Furnace R801 S (Downflow) Series 80% A.F.U.E.t Input Rates 50-150 kBTU tA.F.U.E.(Annual Fuel Utilization Efficiency)calculated in accordance with Department of Energy test procedures. 1 ^� t • 80% residential Gas Furnace CSA certified • Low profile 34" cabinet ideal for space constrained • PlusOne- Diagnostics - 7 Segment LED all units installations • Integrated Control board features dip switches for easy • PlusOne- Ignition System-DSI for reliability and longevity system set up • Heat exchanger is removable for improved serviceability. . QR code for quick access to product information from your Aluminized steel construction provides maximum corrosion smart phone or tablet resistance and thermal fatigue reliability. INTEGRATED HOME COMFORT FORM NO.G11-547 REV.1 Air Table of Contents �i R801S(DF)Series TABLE OF CONTENTS Standard &Optional Equipment ......................................................................3 Model Features/Physical Data&Specifications..................................................4 Model Number Identification............................................................................5 DimensionalData............................................................................................6 Blower Performance Data................................................................................7 Accessories....................................................................................................8 LimitedWarranty ............................................................................................9 COMFORT2 INTEGRATED HOME Air Standard&Optional Equipment a R801S(DF)Series I llllll l lt�_ • �till Npir .r- .. ..„t•f s sl HEAT EXCHANGER INTEGRATED FURNACE CONTROL 4 Y - DRAFT INDUCER MOTOR DIRECT SPARK IGNITOR _ WITH REMOTE SENSE - - IN-SHOT BURNERS STANDARD EQUIPMENT OPTIONAL EQUIPMENT Completely assembled and wired; induced draft; pressure NOTE: Furnace is not listed for use with fuels other than switch; redundant main gas control; blower compartment door natural or L.P. (propane)gas. safety switch; solid state time on/time off blower control; limit The complete terms of limited and other warranties are control; manual shut-off valve, pressure regulator for natural available at our sales office,or through local installer. and L.P. (propane)gas;transformer;direct drive multi-speed blower motor. Furnaces are equipped with cooling/heating All models can be converted by a qualified Rheem distributor relay and transformer(40VA)ready for air conditioning or local service dealer to use L.P. (propane)gas without applications. (Please note: a thermostat is not included as changing burners. Factory approved kits must be used to standard equipment.) Flame sensor diagnostics; udboard convert from natural to L.P. (propane)gas and may be ordered twinning;fused-protection(secondary),3rd speed option for as optional accessories from a Rheem parts distributor. continuous fan;common heat/cool terminal. For L.P. (propane)operation, refer to Conversion Kit Index Form. NOTE: For natural and L.P. (propane)gas models, direct spark ignition is 100% lockout type. WARNING FURNACETHIS NOT "APPROVED 1' RECOMMENDED 1' USE IN MOBILEHOMES COMFORTINTEGRATED HOME Air Model Features/Physical Data&Specifications a R801S(DF)Series Model Features • 80% residential Gas Furnace CSA certified • Low profile 34" cabinet ideal for space constrained • PlusOne'" Diagnostics - 7 Segment LED all units installations • Blower shelf design-serviceable in all furnace orientations • PlusOne'"" Ignition System-DSI for reliability and longevity • Integrated Controls board features dip switches for easy • Heat exchanger is removable for improved serviceability. system set up Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability. • QR code for quick access to product information from your smart phone or tablet Physical Data and Specifications U.S.and Canadian Models MODEL NUMBERS R801SA R801SA R801SA R801SA R801SA R801SA R801SA R801SA R801S(DOWNFLOW) 050314Z*A 075317Z*A 075417Z*A 100317Z*A 100421Z*A 100521Z*A 125524Z*A 150524Z*A Input-BTU/Hr[kW]02 50,000[15] 75,000 [22] 75,000 [22] 100,000[29.3] 100,000[29.3] 100,000[29.3] 125,000[36.6] 150,000 [44] Heating Capacity BTU/Hr[kW] i0 41,000[12] 60,500 [18] 60,500 [18] 80,000 [23] 80,000 [23] 81,000 [24] 99,000 [29] 120,000 [35] High Altitude Input[kW] 45,000[13] 67,500[19.8] 67,500[19.8] 90,000[26.4] 90,000[26.4] 90,000[26.4] 112,500 [33] 135,000[39.6] High Altitude Output 36,500[10.7] 54,000[15.8] 54,000[15.8] 72,000[21.11 72,000[21.1] 72,500[21.2] 89,000[26.1] 107,500[31.5] Capacity[kW] Heat Ext.Static Pressure[kPa] .10[.025] .12[.029] .12[.029] .15[.037] .15[.037] .15[.037] .20[.05] .20[.05] Blower(D x W)[mm] 11x6 11x6 11x7 11x7=10*AM 11x10 11x10 11x10 11x10 [279 x 152] [279 x 152] [279 x 178] [279 x 178] [279 x 254] [279 x 254] [279 x 254] [279 x 254] Motor H.P.[WI-Speeds[W]- 1/2-4-PSC 1/2-3-PSC 3/4-3-PSC 1/2-3-PSC 1/2-3-PSC 3/4-3-PSC 3/4-3-PSC 3/4-3-PSC PSC Type [373] [373] [559] [373] [373] [559] [559] [559] Motor Full Load Amps 6.8 5.8 9.5 7.1 7.9 9.5 9.5 9.5 Heating Speed LOW MEDIUM LOW IVIED IVIED LOW LOW LOW Cooling Speed HIGH HIGH HIGH HIGH HIGH HIGH HIGH HIGH Cooling CFM @.5"[kPa]E.S.P. 1200 1200 1600 1200 2000 2000 2000 2000 (Nominal)[Us] [566] [566] [755] [566] [944] [944] [944] [944] Rated E.S.P.(In.W.C.)[kPa] 0.5[.12] 0.5[.12] 0.5[.12] 0.5[.12] 0.5[.12] 0.5[.12] 0.5[.12] 0.5[.12] Temperature Rise Range°F 25-55 30-60 25-55 45-75 40-70 40-70 40-70 50-80 [°C] [13.9-30.6] [16.7-33.3] [13.9-30.6] [25-41.7] [22.2-38.9] [22.2-38.9] [22.2-38.9] [27.8-44.4] Max.Outlet Air Temp.°F 155 165 155 190 190 170 180 170 [°C] [68.3] [73.9] [68.3] [87.8] [87.8] [76.7] [82.2] [76.7] Approx.Shipping Weight(Lbs.) 85 105 105 L[52.2] 120 120 140 150 [kg] [38.6] [47.6] [47.6] [54.4] [54.4] [63.5] [68.0] AFUE-Electric Ignition Models O 80% 80% 80% 80% 80% 80% 80% NOTES:All models are 115V,60HZ,10.Gas connection size for all models is 1/2"N.P.T. O In accordance with D.O.E.test procedures. O See Conversion Kit Index Form for high altitude derate in U.S.applications. [ ]Designates Metric Conversions 4 INTEGRATED • • •- --00 Air Model Number Identification a R801S(DF)Series Model Number Identification—Downf low Models R 80 1 S A 075 4 17 Z S A Rheem 80= 1 =Single Stage S=Standard Design Series Input 3=Up to Cabinet Z=Down X=Low NOX Revision- 80%AFUE PSC A=1 st Design BTU/HR[kW] 3 Ton Width and Zero S=Standard Marketing 050= 50,000[15] 4=Up to 14=14" Clearance (A—First Time 075= 75,000[22] 4 Ton 17=17.5" Downflow Release) 100=100 000[29] 5=Up to 21 =21" 125=125:000[37] 5 Ton 24=24.5" 150=150,000[44] [ ]Designates Metric Conversions INTEGRATED • • •- Air Dimensional Data a R801S(DF)Series Downflow Dimensions 7/16" TOP BOTTOM [11 mm] RETURN SUPPLY 193/4" P41/2' AIR AIR [502 mm] [622 mm] L 7' LA I l.— C E 3/4 281/16"[713 mm] A [19 mm] R.A. 5/a" B 5/s"116 mm] D 20Va" 5/9" [16 mm] �[511 mm]� [16 mm] 3!4„ 265/a„ [19 mm] 1676 mm] 6 [676 mm] 1/2"DIA.113 mm] LOW VOLTAGE [22 mm] ELECTRICAL 34" CONNECTION [864 mm] (HIGH VOLTAGE) 233/e" 0 0 233/a" [594 mm] [594 mm] 2613h6" 203/a" 1681 mm] [518 mm] 247/1s" 203/8" [621 mm] [518 mm] f T---—�: GAS CONNECTION 63/16" 63/16" 7leDIA. 1157 mm] 1157 mm] 135 mm] LEFT SIDE FRONT RIGHT SIDE Dimensions and Clearance to Combustible Material (inches) [mm] MODEL REDUCED CLEARANCES(IN.)[mm] R801S A B C D E LEFT RIGHT SHIP.WGTS. (DOWNFLOW) SIDE SIDE BACK TOP FRONT VENT (LBS.)[kg] SERIES 050 14 [356] 1227/32[326] 103/8[264] 10 131/8[333] 0 4 02 0 1 [25] 3[76] 6[152]OO 85[38.6] 075 171/2[445] 1611/32[415] 121/8[308] 10 165/8[422] 0 3 02 0 1 [25] 3[76] 6[152]03 105[47.6] 100317 171/2[445] 1611/32[415] 121/8[308] 10 165/8[422] 0 30 0 1 [25] 3[76] 6[152]Os 115[52.2] 100421 21 [533] 1927/32[504] 137/8[352] 10 201/8[511] 0 0 0 1 [25] 3[76] 6[152]OO 120[54.4] 100521 125 241/2[622] 2311/32[593] 155/8[397] 10 235/8[600] 0 0 0 1 [25] 3[76] 6[152]03 140[63.5] 150 241/2[622] 2311/32[593] 155/8[397] 10 235/8[600] 1 0 0 0 1 [25] 3[76] 6[152]OO 150 [68] NOTES: D May require a 3"[76 mm]to 4"[102 mm]or 3"[76 mm]to 5"[127 mm]adapter. 02 May be 0"[0 mm]with type B vent. 03 May be 1"[25 mm]with type B vent. Furnaces must be vented in accordance with the National Fuel Gas Code,ANSI Z223.1 and in accordance with local codes. [ ]Designates Metric Conversions 6 INTEGRATED • • •- Air Blower Performance Data a R801S(DF)Series Blower Performance Data—Downf low Models MODEL BLOWER MOTOR CFM [L/sl AIR DELIVERY R801S SIZE H.P. BLOWER EXTERNAL STATIC PRESSURE INCHES Wal WATER COLUMN (DOWNFLOW) SPEED SERIES [mm] 1W1 .1 [.02] .2[.051 .3[.07] .4[.101 .5[.12] .6[.151 .7[.17] LOW 735[3471 715 [3371 690 [3261 660 [311] 635 [3001 605 [2861 575[271] 050 11 x 6 1/2 MED-LO 1025[4841 1015 [4791 995 [4701 975 [4601 955 [4511 930 [4391 905[4271 [279 x 152] [373] MED-HI 1185[559] 1165 [5501 1150 [5431 1130 [533] 1100 [5191 1075 [5071 1040[491] HIGH 1345[635] 1330 [628] 1310 [618] 1295 [611] 1265 [597] 1235 [583] 1205[569] LOW 1104[5291 1081 [5101 1050 [4961 1025 [4841 999 [471] 971 [4581 940[4441 075317 [279 x 152] [373] MED 1284[6061 1269 [5991 1236 [5831 1206 [5691 1179 [5561 1139 [5381 1102[5201 HIGH 1478[6981 1438 [6791 1397 [6591 1362 [6431 1392 [6571 1282 [6051 1242[5861 LOW 1210[571] 1205 [569] 1195 [5641 1180 [557] 1165 [5501 1155 [5451 1130[533] 075417 [279 x 178] [373] MED 1580[7461 1560 [7361 1550 [7321 1530 [7221 1495 [7061 1465 [6911 1430[6751 HIGH 1915[9041 1880 [887] 1825 [8611 1790 [8451 1740 [8211 1675 [7911 1600[7551 LOW 1070[5051 1055 [4981 1040 [491] 1010 [477] 980 [4631 945 [4461 905[4271 100317 [279 x 178] [373] MED 1240[5851 1210 [5711 1190 [5621 1165 [5501 1135 [5361 1095 [5171 1055[4981 HIGH 1420[6701 1395 [6581 1370 [6471 1340 [6321 1305 [6161 1265 [597] 1220[5761 LOW 1303[6151 1304 [6151 1280 [6041 1250 [5901 1222 [5771 1188 [557] 1160[5471 100421 [279 x 254] [373] MED 1697[8011 1674 [7901 1655 [7811 1638 [7731 1621 [7651 1581 [7461 1542[7281 HIGH 2078[9811 2068 [9761 2037 [9611 2010 [9491 1988 [9381 1938 [9151 1898[8961 LOW 1690[7981 1670 [7881 1655 [7811 1615 [7621 1585 [7481 1565 [7391 1525[7201 100521 [279 x 254] [559] MED — 2085 [9841 2055 [9701 2005 [9461 1970 [9301 1945 [9181 1880[887] HIGH — 2410[11371 2355[11111 2305[10881 2240[10571 2165[10221 2100[9911 LOW — 1690 [7981 1660 [7831 1635 [7721 1580 [7461 1535 [7241 1480[6981 125524 [279 x 2541 [559] MED — 2090 [9861 2035 [9601 1985 [937] 1930 [911] 1850 [8731 1785[8421 HIGH — 2395[11301 2335[11021 2260[10671 2185[10311 2080 [9821 1965[9271 LOW 1675[7911 1650 [7791 1620 [7651 1570 [7411 1545 [7291 1485 [7011 1425[6731 150524 [279 x 2541 [559] MED 2105[9931 2075 [9791 2035 [9601 1990 [9391 1955 [9231 1900 [897] 1815[8571 HIGH — — — — — — — NOTES:Recommended blower speeds are in bold. [ ]Designates Metric Conversions ---Oan INTEGRATED • COMFORT 7 Air Accessories �i R801S(DF)Series DOWNFLOW ACCESSORIES DOWNFLOW WARNING:Unit design is certified for installation on GXGP-F03 non-combustible floor.A special factory supplied combustible PARALLEL FURNACE KITS—are for parallel operation requirements. floor sub-base is required when installing on a combustible floor.Failure to install the sub-base may result in fire,property damage and personal injury. RXGF-CC* FILTER RACK—Downflow top return mount.Requires(2)14 x 20 filters. COMBUSTIBLE FLOOR BASE DIMENSIONS NOTE:Filter racks are shipped without filters. COMBUSTIBLE USE WITH A B C *Filters available through PROSTOCK®. FLOOR BASE FURNACE SIZES IN.[mm] IN. [mm] IN. [mm] RXGC-1314 801 SO50 141/2[368] 131/4[337] 111/4[286] RXGC-B17 801S075,801SA100317 18 [457] 163/4[425] 143/4[451] RXGF-DB* RXGC-B21 801 SA100421, 21 1/2[546] 201/4[514] 181/4[464] Each order contains(1)one box of 10 filter racks supplied without filters. 801SA100521 RXGC-B24 801 S125,801 S150 125 [635] 233/4[603] 213/4[552] *Filters available through PROSTOCK°. FOR HIGH ALTITUDES: �[495mm]—►i HIGH ALTITUDE OPTION CODE:U.S.- ------ -- -__= None required for high altitudes. HIGH ALTITUDE CONVERSION KITS:U.S.- None required for high altitudes. �i 80+HIGH ALTITUDE INSTRUCTIONS -- - -71 Caution:Always follow National Fuel Gas Code(NFGC)guidelines /a" 64 mm] J when converting for high altitudes. [7283mm] A e l High altitude option codes are not required for these models. However,the burner orifice size needs to be recalculated and verified '�[�r k .r% • •, 25 mm] at elevations above 2000 ft.See Installation Instructions for more FIBERGLASS 4„ 3" 4 3 LB.[1.4 kg]DENSITY [102 mm][76 mm] FIBERGLASS information. [51 mm] 2" 3 LB.[1.4 kg]DENSITY FLOOR PLENUM OR __ _ 3"[76 mm] DUCTWORK [ ]Designates Metric Conversions I_ 4 m [56 mm] NOTE:FLOOR OPENING 211/2"1546 mm]x B MAX.PLENUM SIZE 191/2"[495 mm]x C 8 INTEGRATED HOME COMFORT Air Limited Warranty D R801S(DF)Series GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product Heat Exchanger ......................................Twenty(20)Years which fails in normal use and service within the applicable Conditional Parts(Registration Required)........Ten (10)Years period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions,contact your local contractor or the Manufacturer for a copy of the product warranty certificate. INTEGRATED • • •- Air Notes -a R801S(DF)Series 10 INTEGRATED • • •- Air Notes a R801S(DF)Series INTEGRATED • • •- The new degree of comfort.- In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice. Rheem Heating,Cooling&Water Heating • P.O.Box 17010 Rheem Canada Ltd./Ltee • 125 Edgeware Road,Unit 1 Fort Smith,Arkansas 72917 • www.rheem.com Brampton,Ontario • L6Y OP5 0 INTEGRATED HOME COMFORT PRINTED IN U.S.A 7/14 QG FORM NO.G11-547 REV.1 Permit#: 837 Permit Date: 11/13/15 Permit Type: RESIDENTIAL MECHANICAL Project Name: Gloria Bruce Applicant Name: CM Heating Inc Applicant Address: 1415 Broadway Applicant, City, State, Zip: Everett,WA 98201 Contact: Meredith Gilbert Phone: 425-259-0550 Email: meredith@cmheating.com Scope of Work: Gas Furnace Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 11/13/2015 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00928200008300 19324 46TH AVE NE BRUCE,GLORIA 111 Single Family Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Plumbing CMHEAHL750LP ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Construction CMHEAHL751 W ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION UBI 605890285 ST STE 200 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 12/22/2015 R00.FURNACE 12/22/2015 BUILDING Approved FINAL Fees Fee Description Notes Amount Forced Air Heat fee per Btu $25.00 Mechanical Base Permit Fee $25.00 Total $50.00 Attached Letters Date Letter Description 11/13/2015 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 11/13/2015 Deborah Bauer 56981646 cc $50.00 Outstanding Balance $0.00 Notes Date Note Created By: 11/13/2015 Model#EL280DF090P48B-AFUE 80%-Duct testing is required per R101.4.3.1 Amy Rusko Uploaded Files Date File Name 12/22/2015 1404555-19324 46th Ave.docx 11/24/2015 1374156-19324 46th Ave Signed Permit.pdf 11/13/2015 1361095-Residential Mechanical 1FbXBSENazI3DJ.pdf 11/13/2015 1361094-fetchdocument-rh.pdf RESIDENTIAL MECHANICAL 01" "" PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:19324 46TH AVE NE Project Description: INSTALL GAS FURNACE Owner: GLORIA BRUCE Address: 19324 46TH AVE NE City: ARLINGTON State-.WA Zip Code: 98223 Phone: 360 213 5394 Email-MEREDITH@CMHEATING.COM Applicant: CM HEATING Address: 1415 BROADWAY City: EVERETT State WA Zip Code: 98201 Phone: 425-259-0550 Email: MEREDITH@CMHEATING.COM CONTRACTOR INFORMATION Contractor Name:CM HEATING Address: 1415 BROADWAY City: EVERETT State'.WA Zip Code: 98201 License Number:CMHEAMH877DN Expiration: 5/17 Phone-425-259-0550 Email:MEREDITH@CMHEATING.COM STAFF USE ONLY Permit #: Accepted by: Date: RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 SELECT ALL PROPOSED APPLIANCES Q Furnace (80+) Model # R801 SA050314MSA AFUE 80 ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: ❑ Pipe Material: Pipe Size: Distance From Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: Date: 11/12/2015 Applicant Printed Name: Meredith Gilbert l hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington.