Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18513 59TH AVE NE_BLD1169_2026
Y °�' COMMERCIAL PLUMBING PERMIT APPLICATION Department of Community&Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF CONSTRUCTION DRAWINGS, AND TWO (2) SETS OF FIXTURE SPECIFICATIONS (CUT SHEETS). CALCULATIONS ARE REQUIRED FOR GREASE INTERCEPTOR/F APPLICABLE. Type of Permit: ❑ New Installation i Addition/Alteration ❑ Industrial Project Address: ��,I� �''1J lUL Parcel ID#: Lot#: Subdivision: I-'II � Project Description: �/ 4- 6 J r, C L6 A&Atm Valuation Q/ ocn Owner: Nb 4 r���r hr� Phone Number: Address: � 513 S��- Ave- 4ZE City: State:—UZip Code: Contact Person: Mike Am4na,J' a Phone Number: 3bO 7N k'i 1 Cell Phone: VA 3P A).a E-mail: r l ke I,v���C►�� ,Lois Address: 7�,Z !fig City: IRCYL-0 State: A Zip Code: 907d, Contractor: do =- 01L4Mk)V%.a Phone Number: 30 Cell Phone: i-Q - 17- 7q2. Email: h ke- n W"')e I . Qn rn Address: 17 3*q1 1t4e ST- SE- City: Stater_ Zip Code: 2t)72 Contractor License Number: W4LCE PT,,33C3" Expiration Date: nrt r Please indicate number of fixtures: Water Closet 3 Floor Sink Sump Hose Bibb '��A}is(('�ellaneous ICR.1 Gr•ccifl Lavatory Laundry Tub Washer Water Heater Grease Trap Urinal I Interceptor Sink Med Gas __ _ _ Drinking Fountain Floor Drain Dishwasher Backflow Shower Other 6/16LP Page 2 of 3 Y °fi COMMERCIAL PLUMBING PERMIT APPLICATION Department of Community&Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551 PROPOSED BUILDING USE ❑ New Commercial ❑ Restaurant ❑ Automotive Based Commercial Addition/Alteration ❑ Office ❑ Machine Shop ❑ Industrial ❑ Medical ❑ Other: CROSS CONNECTION Please check all appliances that are proposed or are permanently connected to the water supply. ❑ Ice Machine ❑ Dialysis Equip. ❑ Air washers ❑ Swimming ❑ Fire Sprinkler Pools ❑ Coffee ❑ HydrotherapyEquip. 1-1Tub/Spa Steam ❑ Sprinkler Urn/Espresso qp. Generators ❑ w/chemicals ❑ Carbonated Bev. ❑ Dental Equip. ❑ Dye Vats ❑ Aquarium ❑ Lawn Irrigation ❑ Fume Hoods ❑ Laboratory Equip. ❑ Pressure ❑ Decorative ❑ Well on Washers Fountain property ❑ Degreasers ❑ Autoclave/Sterilizers ❑ Cooling Towers ❑ Other: WASTEWATER DISCHARGE 1. Does the plumbing system currently have a grease interceptor? ❑ Yes No Don't Know Date grease trap/interceptor was last cleaned (provide service record): 2. Does the plumbing system currently have an oil/water separator? ❑ Yes ❑ No ❑ Don't Know 3. Date oil/water separator was last cleaned (provide service record): 4. Is water used in the business process(washing, rinsing,cooling)? ❑ Yes ❑ No ® Don't Know 5. Does your business require a NPDES permit? ❑ Yes —,1 No ® Don't Know I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above-described property will be in ac rdance with the Jaws, rules and regulation of the State of Washington. �- ,/ � �,r A is nature Date Print Applicants Name FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received 6/16LP Page 3 of 3 ENLARGED PLAN GEN. NOTES: I . REF. A1.00 FOR SEVERAL NOTES 4 DIMENSIONINS CONVENTIONS. • 2. REF• A2.03 FOR GEILIN6 LESEND AND NOTES • S. REF, A4.0 FOR INTERIOR 1`IALL TYPES. 4. KEYED NOTES REFER TO EQUIPMENT AND ACCESSORY oo M4 - g, REF. A6.01 FOR ACCESSORY MOIINTIN6 CODE H V-1 ALIEN NEVI TO I REQUIREMENTS. MATCH EXISTINS HEIGHT EXISTING + 10 r LO 15 ' 1 S � ■ 'D Connect new ----� �% 1e 13 lavatory drains to Connect new lavatory drains 06 06 existing EOLC to existing floor drain vent 1 I ' Connect new I 1 rol drains to existing ""' ' ""' """' 1 1>FIav1De GLEpNouT D.S. TO TIGHT LINE waste piping 14 0I v c 1 O a ® ■ Remove existing shower AND ACCESS PANEL. AT O5 0-1 1oe DINS 12 ___- valves and use hot&cold 42" A.F.F. 9r - . water supplies for lavatories ExI5TINNi WALL. '` 08 08 t2 IXK4LLTINb G.M.0 It 10 ® N O • _ 3�'TAI .....'b....... aw cut area. - , 0 Extend existing wat t i ` O6 piping for new toilet AT and urinal V-I -----1 AB V6 2 2'- ' s 13 EXISTING ■ HEIGHT i �ENLAR6ED PLAN ALISN NON To EXISTINS �.,� ENRGED PLAN i L 1/ LALA I• At Received OCT 12 2016 ACCESSORY SCHEDULE MOUNTING ROUGH4N REG. PURNISW INSTALL TAG DESCRIPTION BASIS OF DESIGN MANUFACTURER,SAES,PRODUCT NO LOC. EL.EC I PLM I OAS FJ.C. I F.O.C.I.I N.I.C. REMARKS 01 CORNER GUARDS ACROVYN CO-8,STAINLESS STEEL X A. 02 FIRE EXTINGUISHER&CABINET LARSEN,2720 SM.SOLD DOOR,ALUM.TRIM SR X 03 LOW FLOW FLOOR MOUNTED TANK STYLE TOILET REF PLUMBING DRAWINGS MERICAN STANDARD F NOT INDICATED) X X 04 WATER CLOSET SEAT REP PLUMBING DRAWINGS(AMERICAN STANDARD F NOT INDICATED) X 03 P.LAM COUNTER 2-A.F.F. COLOR TO BE SELECTED FROM MANLIF.STANDARD SELECTION X 2 08 TOILET PAPER ROLL DISPENSER BOBRICK,B-2890 SM X V 07 TOILET SEAT COVER DISPENSER BOBRICK,04221 SM X (n 08 SOAP DISPENSER BOBRICK.B4112 SM I X OB PAPER TOWEL DISPENSER SOSRCK,B3620 SM X 10 WALL MOUNTED LAV AND DRAIN(W PPE NSUL) REFERENCE PLUMBING DRAWINGS X I X C 11 LAV FAUCETSET REFERENCE PLUMBING DRAWINGS(ELKAYBRAND F NOT INDICATED) X X C 12 FRAMED MLRROR BOBRICK,B•165 2438(24)W MIRROR) X cc 13 COAT HOOK WI BUMPER BOBRICK 11-212 MOCATED ON BACK OF DOOR X D 14 SANITARYNAPKIN DISPOSAL 80BRICK,8-270 X 15 TOILET PARTITION MATCH EXISTING PARTITIONS X 0 18 LOW-FLOW URINAL REF PLUMBNG DRAWINGS(AMERICAN STANDARD F NOT INDICATED) X X 17 SELSMIOJONTCOVERS MICHAELRUACOMPANY X _- 18 BASKETBALL BACKBOARDS PORTER ATHLETIC COMPANY X 0 15 VOLLEYBALL NET&POSTS PORTER ATHLETC COMPANY X C 20 ATHLETIC BLEACHERS X GENERAL 1.NOT ALL ITEMS WILL BE TAGGED IN DRAWINGS MOUNTING LOCATIONS: FURNISH INSTALL ABBREVIATIONS: � a (NOTES: 2.N FRAMED WALL PROVIDE BLOCKING FOR ALL EQUPMENTPER BACKING PLATE DETAILS Ro RECESSED F.I.C. FURNISHED&INSTALLED SYCONTRACTOR Or>nNr>A. 3.REFERENCE ACCESSORY MOUNTING DAGRAMS FOR CODE REQUIRED MOUNTING HEIGHTS SR-SEMN RECESSED F.O.C.L FURNLHED BYOWNER CONTRACTOR NSTALLED SWSURFACEMOIMTE N.LC. NOTNCONTRACT RFURNISHEDANDNSTALLE ^� SPECIFIC A. TYPICALATALLOUTSDECORNERSATGWS.CONSTRUCTION !'•11 REMARKS 8. ONE SET EQUALS 135',142'1.18'(VERTICAL) ,au.,... C. NSUATE INDER SINK PPES PERADA REQUIREMENTS D.LOCATEHANDLEAT48'A.F.F.PERAA' eD 1 —A2.QQ —.. i_ �rr�irrriirrriinirrrr, orrrrrrrr I — — CONTINUED A2<C —62,01 A2.01 I / 0 P GYM. OFFICE i ' i - - "AL` As HA T"G4-IC ARE:/V 104 - 9 GYM «I sTOR "X 1 5 I N ~ g •p / /� " lc,Al V D SNOT I N �I75 L' 0 * _j TI roof y _ A 56 2I 96 « — / tL ~ 1 Eain 0 02 w e r — /� o to they on _ AI v SB - ' "-I ro d pi __ val cal stack �_ &A G A5 v t a Is t A m E , LOBBY -.4• 13'-2" 101 E B 1 AD © AD of L5 5 - -- -- I Connect to outdoor A I 1 _storm water piping QD 1 1 ®, G 1 �H1O - I L___)&-_-__ _J ___-_-_- _ _J L---------- ---J 1O SYN. I r 5S I ;a -- I g _ 6YMNA5i l/M TWO A I V I _ A2 V I I I _ _1 � ALT�2 - 100 "9-_ 9'-4' A.F.F. -�F'- - 'F _ � I '`E`CTER I OR MAIN rM r I I 1 r 1 0 r w i METAL ISLDYi. NAPIIF. �r GSM I I B I I ALT 1 PLYMD. ON INTERIOR TO 8' A.F.F. _ I - - —- - - I/Dr' AL I - - - - - - - - g '-15T o 12' O.G 1I �'' I n�i r 1 I. GAP I /r� Ao 0 ��--__� I 55 I A° EACH SIDE i u� io A2 VI I p 1 ..,- SIF>lJGT. STEEL , �' + PER METAL I ; - I REF. 1 /A . 06 FOR COURT AYOUT I 8'-0° A.F.F. I r WALL PAD AND COURT STR PINGCRASH � I - To EXTEF> PADS IC (TENT3 INDICATED ON COURT LAYOUT PLAN ® _ sg JVI --COLUMN YRAP A2(TW-) 8'-0" A. .F. A I A2 1/1 8'-0' A.F.F r N.T.S. Q , I I 1 I A I ID 1 A I ----------- S. 5. 9. ----- 9. _5.----- ---- Pag J A A D I I I I ( D 25'-0' 25'-0" 25,_0" 25'-0 25'_0,. 25,_0. QQQ 7 A U PLAN GENERAL NOTES: PLAN KEYED NOTES: ® RV>M IN CONDUIT FOR BOARD• 18'-0" A.F.F. ° TER T ALTNATE 1. THE 6E�tAL CONTRACTOR I5 RESPONSIBLE FOR THE ACCURATE � HE MN tT OF THE BUILDING ON THE SITE. VERIFY ALL ® RO FRONT LIFT RETRACTABLE BASKETBALL BACKBOARD (BOTH ENDS BED AS BID) PLAN 5YMBOL5 LEGEND DIMENSIONS AND EXISTING CONDITIONS PRIOR TO PLACEMENT (MANUAL LIFT) ® R120cA�6As STANDARD SYMBOLS AND NOTES ON A1.00 FLOOR PLAN EA5T-----4 NOTIFY THE ARCHITECT OF ANY DISCREPANCIES FOR ® FIXED BASKETBALL BACKBOARD ® 6' X 6' GONG. STOOP SLOPE FROM SLD6 RESOLUTION IN MRITIN6. DO NOT SCALE DRAlYLM6 PitTTbi(,t6 -%+7eN ARE FROM FACE ® CR��T WALLS AT X BRACING AND PROVIDE 2" © SILSE BID LOCATION FOR DOUBLE DOOR, CONNECT 2. CRASH PADS ON F.O.WALL REF. COURT STRIPING ID9MLK TO FJCI5TIN6 U-- EXTERIOR HALL TYPE VA OF MASONRY, C047MINE o`- 5TRJG1VRAL 6RID OR FACE OF FOR EXTENTS (W INTERIOR FACE OF WALL IN 6YM..TO HAVE 5/4' >% STUD. DIMEMIONS INDICATED A5 +/-OR V.I.F. ARE ® EDGE OF RECESSED SLAB DETAIL PLYMP. FLOOR TO Ge1LING THROUGHOUT ss 2 EXTERIOR HALL TYPES o APPROXIMATED AND TO BE VERIFIED IN FIM.P. DIMENSIONS 2/A2.06 INTERIOR PARTITION TYPE Rt�A4.0 REP. A4.00 FOR INT R1,OR PARTITIONS TYPES m INDICATED AS CLEAR OR 'CLR' ARE CODE DIMENSIONS AND ® FWrABLE BLEEGH6t LOCATION - FOR REFERENCE AZl'/5 y TAKE PRECEDENCE TO OTHER DIMENSIONS INDICATED. ® Si1RFAGE MOUNTED F:E.G. (O� FURNISHED AND INSTALL®) • A2.01 FOR ADDITIINIV- EXTERIOR WALL INFO S. ALL OUTSIDE CORNERS OF 6.W.S. TO R86EIVE CdRNER BEADS ® hRAP ALL COLUMNS AND B.B. COURT ENDS W/ 2" C AND CORNER GUARDS. REF. FINISH SCHEDULES FOR MORE WN•L GRAPH PADS A5 INDICATED ON COURT PLAN ( SIDEYIALK TO EXTENTS SHOW, RIP. SITE PLAN AND FIRE EXTIN6UISHER CABINET WITH 5« AEG/ RATO Q NEE-MANUFACTURER BUILT BUILDING EXTERIOR WALLS � PER MANUFACTURER BUILT TO A VALUE OF R-19 3/AI01 2A IOBG EXTIN6Ui5H�. TO COMPLY W:AII'1.1 G INFORMATION. (BOTH END OF FULL COURT IF ALT 01 NOT USED) . II 5EGTION 501 REQUIREMENTS, MOUNT 50 HANDLE 15 © WOOD STUD WALLS WITH EXTERIOR STUCCO CLADDIN6. 4. CONTRACTOR AND SUBS SHALL NOT HANG ANYTHING FROM ® INSTALL OCCUPANCY 5I6N W/ 6RAPHICS PER I.B.G. RATS®CURB REF. GIV1L DRAW1N66 AT 48° A.F.F. BUILT TO A VALUE OF R-I9. R3e34NGE IIALI. CONDUIT, DUCTS OR PIPING. ALL 5U5PEWW ITEMS SHALL 'TOTAL OCCUPANCY NOT TO EXCE 7 BOO OCCUPANTS, SECTIONS FOR MORE INFORMATION, a BE HUNG FROM STRUCTURAL ELEMNT5. DUCTS SHALL NOT BE �® KEYED NOTE © METAL STUD WALLS W1TH EXTERIOR STUCCO CLADDING. EHI PETRATSI BY ELECTRICAL, FIRE SUPP1�56ION OR ANY ® NEV KA L SHALL NOT HINDER EXISTING ROOF BUILT TO A VALUE OF R-14, ROE WALL OTHER SYSTEM. LADDER OR HATCH. Drawing. SECTIONS FOR MORE INFORMATION, 5. 6ENERAL NOTES LISTED ON THIS PAGE ARE NOT INTENDED TO ® REPLACE EXI5TIN6 D.S. WITH NEW PIPE TO T16HT o EXI5TIN6 WALL ® EXISTING G.M.U. WALL D❑ ALT«2 - 8" (NOMINAL) G,M.U. PONY WALL /I, BE AT THE EXCLUSION OF NOTES LISTEW E15BiNEF�: THI5 LINE. NEV WALL -•-. I HOUR RATING REF, ELEVATIONS 1 SECTIONS FOR EXTENTS /""tr DOCUMENT SET IS MEANT TO BE COMPLIMENTARY, AND NOTES Qo ROUGH IN CONDUIT 1 OUTLr=T FOR scow BOARD METAL STUD WALLS WITH EXTERIOR STUCCO CLADDING LISTED ON OTHER SHEETS MAY HAVE BEARIN6/,APPLICATION JACK - - ❑E TO MOW SHOW HEFE. - 2 HOUR RATING BOTH SIDE, RMGE WALL SEC RE TIONS FOR MO INFORMATION SIM. EXTERIOR WALL 'G' r' CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address: 18513 59th Avenue NE Permit#:1169 Parcel#:3 1052200103 100 Valuation:20000.00 OWNER APPLICANT CONTRACTOR Name:ARLINGTON CITY OF Name:Wolfe Plumbing Name:Wolfe Plumbing Address: 18204 59TH DRIVE NE Address:17321 Tye Street SE,#B Address: 17321 Tye St SE,#B City,State Zip:ARLINGTON,WA 98223 City,State Zip:Monroe,WA 98273 City,State Zip:Monroe,WA 98272 Phone: Phone:360-794-8621 Phone:360-794-8621 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name:Wolfe Plumbing Address: Address: 17321 Tye St SE,#B City,State,Zip: City,State,Zip:Monroe,WA 98272 Phone: Phone:360-794-8621 LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Plumbing CODE YEAR: 2015 STORIES: 1 CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: 1 OCC LOAD: PE'RNIIT:"APPROVAIa -._ _ _ , ., T r I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI10/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and codVdiWArlington#3 ignature Print Name Date Released By c CONDITIONS Adhere to approved plans. The RPBA will need to be replaced and tested after installation. THIS PERMIT AUTHORIZE ONLY THE WORK NOTED,THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/19/2016 Plumbing Permit Base Fee $25.00 10/19/2016 Plumbing Permit Fee(Enter Fixture Fee) $120 00 10/19/2016 Plumbing Plan Review Fees $300.00 Total Due: $445.00 Total Payment: $0.00 Balance Due: $445.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon �Kvc r6c � 24-, CPO mW FED k300 o0 FIct lee 0� l Zo - Permit Information Date 10/12/2016 Permit Number 1169 Project Name Boys&Girls Club Applicant Name Wolfe Plumbing Applicant Address 17321 Tye Street SE,#B City, State, Zip Monroe,WA 98273 Contact Mike Annunziata Phone 360-794-8621 Email mikea@wolfepi.com F• Permit Type Commercial Plumbing Site Address 18513 59th Avenue NE Valuation 20000.00 Status Applied Permit issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 1 Proposed Use Adding plumbing to commercial addition/alteration Assigned To Launa Peterson Property InformationOwner Information Parcel#:31062200103100 ARLINGTON CITY OF ARLINGTON CITY OF 18204 59TH DRIVE NE 18513 59TH AVE NE ARLINGTON,WA 98223 Contractors Contractor Name Primary Contact • Contractor Type License License# olfe Plumbing 60-794-8621 ONTRACTOR abor&Industries WOLFEPIO33CJ DescriptionReview Date Date Completed Status - 10/12/2016 Commercial Plumbin 10/19/2016 Kevin Olander n Review 10/12/2016 !Commercial Plumbing 10/19/2016 FW Admin Rev n Review '10/12/2016 (Commercial Plumbin 10/19/2016 W-Sew-Rev n Review '10/12/2016 lCommercial Plumbing 110/19/2016 W-Wat-Rev In Review UploadedDate File Upload File Uploaded 10/12/2016 2:45:00 M=an Set,odf etorson, Launa 10/12/2016 2:41:46 PM 11169 A li lion. dfPeterson, Launa Structural slab Underfloor Wallboard Permit Details Date 10/12/2016 Permit Number 1169 Project Name Boys&Girls Club Applicant Name Wolfe Plumbing Applicant Address 17321 Tye Street SE,#B City, State,Zip Monroe,WA 98273 Contact Mike Annunziata Phone 360-794-8621 Email mikea@wolfepi.com Permit Type Commercial Plumbing Site Address 18513 59th Avenue NE Valuation 20000.00 Status Closed Permit Issued 10/19/2016 Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 1 Proposed Use Adding plumbing to commercial addition/alteration Assigned To Launa Peterson Contractors Contractor Name Primary Contact Phone Email Contractor Type License License# Wolfe Plumbing 360-794-8621 CONTRACTOR Labor&Industries WOLFEP1033CJ Property Information Owner Information Parcel#:31052200103100 ARLINGTON CITY OF ARLINGTON CITY OF 18204 59TH DRIVE NE 18513 59TH AVE NE ARLINGTON,WA 98223 Inspection Information Inspection Date 10/27/2016 Type Commericial Requested By Contact Info Scheduled Date Completion Date Description Status Approved Assigned To Hours 0 Notes Property Information Parcel#:31052200103100 RLINGTON CITY OF 4RLINGTON CITY OF 18204 59TH DRIVE NE '18513 59TH AVE NE ARLINGTON WA 98223 431 Airports&Flying Fields Inspection Items Date Employee Pass/Fail Note Building Final Ceiling Grid Cross Connection Fire Final Footing Foundation Framing Gas Piping Groundwork Plumbing 10/24/2016 Kevin Olander Pass Insulation Rough HVAC Rough-In Plumbing 10/27/2016 Kevin Olander Pass No Vent work yet completed.KO Vent work complete 11/3/16.KO Shearwall Y COMMERCIAL PLUMBING PERMIT APPLICATION lI'NGS Department of Community&Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2) SETS OF CONSTRUCTION DRAWINGS, AND TWO (2) SETS OF FIXTURE SPECIFICATIONS (CUT SHEETS). CALCULATIONS ARE REQUIRED FOR GREASE INTERCEPTOR IF APPLICABLE. Type of Permit: ❑ New Installation ® Addition/Alteration Industrial Project Address: 1�" '�(t /f. - AdL Parcel ID#: 31c5 -2220 103� Lot#: Subdivision: Project Description: 12-),11(, Ckub ,�c.�[.��+��� Valuation: Cxf) Owner: /S t Lr�r�S C�,�J �� ��, ��h Phone Number: Address: 3 S��_ A„c !l/G City: A('),h " State: Zip Code: ga' 3 Contact Person: iko Annun-2-olk, Phone Number: �dc _eNZI Cell Phone: 1-W 3a l AXI E-mail: rl)I key o IA kn IQ, ,Loh-\ /� Address: 17?221 ( o SA- SF City: 10,117rm Stater_ Zip Code: `7° , Contractor: WOW-f- dL4r1h)h1 Phone Number: 30 79r.l kk j Cell Phone: 211111 Email: 61 ka-C\ ni. Cn M � t.Jn Ire Address. 17 321 l i pe S�- St City: Aky)fflt Stater_ Zip Code: 2071 Contractor License Number: WoLFE PT(733c_3- Expiration Date: J nkci.^,/ acO Please indicate number of fixtures: Water Closet Floor Sink Sump Hose Bibb ' is((—�ellaneous ICE-1 C7rci1(1 Lavatory �� Laundry Tub Washer Water Heater _ , Grease Trap Urinal I Interceptor Sink _ Med Gas _ _ _ Drinking Fountain, Floor Drain Dishwasher Backflow Shower Other Received OCT 12 2016 �bw 6/16LP Page 2 o I �► Y COMMERCIAL PLUMBING PERMIT APPLICATION �'�r', Department of Community&Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551 PROPOSED BUILDING USE ❑ New Commercial ❑ Restaurant ❑ Automotive Based Commercial Addition/Alteration ❑ Office ® Machine Shop ❑ Industrial ❑ Medical ® Other: CROSS CONNECTION Please check all appliances that are proposed or are permanently connected to the water supply. ❑ Ice Machine ❑ Dialysis Equip. ❑ Air washers ❑ Swimming ❑ Fire Sprinkler Pools ❑ Coffee Steam Sprinkler ❑ Hydrotherapy Equip. ❑ ❑ Hot Tub/Spa ❑ Urn/Espresso Generators w/chemicals ❑ Carbonated Bev. ❑ Dental Equip. ❑ Dye Vats ❑ Aquarium ❑ Lawn Irrigation ❑ Fume Hoods ❑ Laboratory Equip. ❑ Pressure ❑ Decorative 1-3Well on Washers Fountain property ❑ Degreasers ❑ Autoclave/Sterilizers ❑ Cooling Towers ❑ Other: WASTEWATER DISCHARGE 1. Does the plumbing system currently have a grease interceptor? ❑ Yes No i Don't Know Date grease trap/interceptor was last cleaned (provide service record): 2. Does the plumbing system currently have an oil/water separator? ❑ Yes ❑ No 0 Don't Know 3. Date oil/water separator was last cleaned (provide service record): 4. Is water used in the business process (washing, rinsing, cooling)? ❑ Yes ❑ No Don't Know 5. Does your business require a NPDES permit? 11 Yes ❑ No Don't Know I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-described property will be in ac rdance with the aws, rules and regulation of the State of Washington. A is Mature Date " Ain,-) Print Applicants Name FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received 6/16LP Page 3 of 3 A e" S11"da-•d YORKVILLE RIGHT HEIGHTTm ELONGATED Style That Works Better PRESSURE-ASSISTED TOILET 1.6 gpf/ 6.0 Lpf ® BARRIER FREE VITREOUS CHINA YORKVILLE RIGHT HEIGHTTm ELONGATED PRESSURE-ASSISTED TOILET 1.6 gpf/6.0 Lpf ❑ 2878.016 - •Vitreous china • Floor-mounted, back-outlet toilet �t • Low-consumption (1.6 gpf/6.0 Lpf) CITY OF ING • EverClean"'surface inhibits the growth of BUILDING stain-and odor-causing bacteria, mold, and mildew on the surface APPROVED • Elongated 16-1/2" high bowl rim for accessible applications - • Pressure-assisted siphon jet flush action • Fully-glazed 2-1/8" trapway • 10 x 12" water surface area •Close-coupled Flushometer tank* 1JtM.�fSSAPPRCl11ED • Metal chrome trip lever BUILDING INM •Speed Connect"tank/bowl coupling system - • Sanitary dam on bowl •4 bolt caps • 100%factory flush tested _ 3703.016 Elongated 16-1/2" high bowl with 4 bolt caps ❑ 3703.001 Same as above, Universal Bowl ❑ 4142.016 Flushometer tank complete with Ir FINISHED WALI coupling components 752mm 516mm -.1 Nmm i6mm XD.1/2•) Nominal Dimensions: 752 x 516 x 780mm (£' (29-3/4"x 20-1/2"x 30-3/4") 470mm JL) ' � C/L Fixture only, seat and supply by others CIL OF SEAT POST HOLES I 730m"i i•: 1 140mm(5-1/2')CENTER Recommended working pressure range E 25 psi-80 psi '-; °U FL FX 35umm 419rnm AS REQ. X Alternate Configurations Available: i5-°^"^ 1 13 x,9mm ❑ 4142.600 Tank and tank cover only with tank 229mm 102(A; I6°' x3/4•) cover locking device (£) k I 76mm '4- Min, LOIS 4142.800 Tank and tank cover only with right ri hand trip lever 349mm�' 305min� C/L OF ❑ 4142.900 Tank complete with right hand trip r35/6, r "' oUTET �3°n,.^ FINISHED I�CIL O OF 112°DIA HOLES ..- (£'1 -� FLOOR lever and tank cover locking device 169n1m(6-5/0')CENTERS Compliance Certifications- Meets or Exceeds the Following Specifications: NOTES: •ASME A112.19.2-2008/CSA B45.1-08 for Vitreous WASTE OUTLET SEAL RING MUST BE NEOPRENE OR GRAPHITE- FELT(WAX RING NOT RECOMMENDED). China Fixtures SUPPLY NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED SEPARATELY. DISTANCE FROM FLOOR TO CLOSET FLANGE CENTERLINE(ROUGH- IN)MUST BE 4"(102.MM)WITH FLANGE SURFACE FLUSH TO 1/16" (1.510M)MAX.BEYOND FINISHED WALL, To Be Specified: *DIMENSION SHOWN FOR LOCATION OF SUPPLY IS SUGGESTED. ❑ Color:❑ White ❑ Bone ❑ Linen ❑ Black FOR ADDITIONAL INFORMATION REFER TO INSTALLATION INSTRUCTIONS SUPPLIED. ❑ Seat:American Standard#5324.019"Rise and IMPORTANT: Dimensions of fixtures are nominal and may vary within the Shine"(with easy to clean lift-off hinge system) range of tolerances established by ASME At 12.19.2.2008/CSH B45.1-08. Solid plastic Closed front seat with cover. These measurements are subjoct to change or cancellation.No ❑ American Standard#5321.110 EverCleanO responsibility is assumed for use of Suporseded or voiiided,,,���pagos. Seat with SIOW Close Snap Off hinges. MEETS THE AMERICANS WITH DISABILITIES AC+yyyM@O IEU ❑ Alternate Seat: ® AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE ❑ Supply with Stop: BUILDING FACILITIES-CHECK LOCAL CODES. OCT 12 2016 M43 0 2010 AS America Inc. Revised 2/10 rKOTD'/lW.qAqOYTID TM3W,TFtAq�O WICLNUS COO IoaqqA I It-IT Ylb C5voRqRA POT:)3qMDWUJILI8 _ 1„ :4== COMMERCIAL TOILET SEATS COMMERCIAL TOILET SEATS ❑5901.100 Elongated Heavy Duty bowl open front seat less cover ❑5901.100SS Same as 5901.100 with self-sustaining hinge J 5901.110T Same as 5901.100 with EverCleanO Surface 5901.110T5 Master Pack of 5-5901.110T seats individually boxed and labeled for easy sell through •Open front toilet seat less cover •Injection molded solid polypropylene •Fits elongated bowl •Features large molded-in bumpers • External check hinge with 304 Series stainless steel hinge posts stops seat 110 beyond vertical 61mr, A- • EverClean®silver-based surface permanently inhibits the growth of stain and odor causing bacteria, mold and mildew on the surface. EverCleanO surface does not protect against disease causing bacteria. '~ E Modell # 5901 A 18-9/16" (471mm) B 14-3/8" (365mm) A C 7-7/8" (200mm) C D 3-1/2" (89mm) E 5-1/2" (140mm) Ring Thickness 7/8" (22mm) Ring Thickness 1" fD- (25mm) with Bumper B To Be Specified: ❑ Color: ❑ White M165 ©2016 AS America Inc. spec_5901 (4/16) ALLBROUK® FloWiseO UNIVERSAL URINAL VITREOUS CHINA ® BARRIER FREE ALLBROOKO FloWise® UNIVERSAL URINAL • Vitreous china • High Efficiency operates in the range of 0.5 gpf to 1.0 gpf (1.9 Lpf/3.8 Lpf) • Flushing rim • Siphon jet flush action • 3/4" inlet spud • Outlet connection threaded 2" inside (NPTF) i. • Wall hanger • Fixture only • Meets ANSI flush requirements at 0.5 gpf and 1.0 gpf 6550.001 Top spud Nominal Dimensions: 363 x 363 x 546mm (14-5/16" x 14-5/16"x 21-1/2") Recommended working pressure—between 20 psi at valve when flushing and 80 psi static 121mm Compliance Certifications- Meets or Exceeds the Following Specifications: FINIs,lEOWALL S 262mm L<' .T ASME A112.19.2-2008/CSA 645.1-08 for Vitreous sTmm $14' SUP LW China Fixtures 2-1/4") SPUD FLUSH VALVE NANGEn 292m .' 114ry CA 066m.n To Be Specified: 547mn, Color: ❑ White 101mm _0 9 16 (21-112') v Flush Valve: n.. Ivz•) ❑ American Standard Selectronic®#6063.051.002 i____ _ 0. .o DC Power(Top Spud) CILOF O (17') OUTLET LJ Manual American Standard#6045.051.002 610mm �102— 22 N.P.T. '24') (4") (Top Spud) FEMLE OPTIONAL OUTLET TO FINISHED CONNECTION FLOOR GASKET fOnm, I (.N11'1 1 1 f`t � 1 *&TS% I 1 (4) 1 "16mm < N �cm V NAnT. (5'6'S T •�s EPA G� INSIDE THREADS FINIMED WALL ppT�y, DETAIL OF OUTLET CONNECTION 9 �rCIEW�0 When 1uPu RST sed with 0.5 gpf urinal NOTES: flush valves FLUSH VALVE NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED SEPARATELY. PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS. WMEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND ANSI A117.1 ACCESSIBLE AND USEABLE BUILDINGS AND IMPORTANT: Dimensions of fixtures are nominal and may vary within FACILITIES-CHECK LOCAL CODES. the range of tolerances established by ANSI Standard Al12.19.2.These When installed so to of rim is 432mm 17" from finished floor. measurements are subject to change or cancellation.No responsibility Is p j assumed for use of superseded or voided pages. M143 0 2016 AS America Inc. PART OF `I X I` spec_6550.011 AllbrookFW Rev.A 9/16 ODOM- Aq,.aflushO zuRK awl- TAG Z6003 Model for 3/4" Urinals FIN1`-_-1 IED WALL " [57] MIN Z4.. 12 SUPPLY 6L� z V A J(j M 2 2] B V ADA REAKER S1 DE GNED T U B E ENGINEERING SPECIFICATION: ZURN Z6003 Aquaflush FlowOptlons Exposed Urinal Flush Valve -Exposed, quiet diaphragm- • -EWS 0.5 Gallons Per Flush type,chrome plated flushometer valve with a polished exte- • _WS1 1.0 Gal.LowConsumption rior.Complete with a chloramine resistant,dual seal diaphragm • _WS 1.5 Gallons Per Flush with a clog resistant by-pass.The valve is ADA compliant with a non-hold open and no leak handle feature,high back pres- sure vacuum breaker,one piece hex coupling nut,adjustable Suffix Qpffo-RsAChec L$peg*ApprggdAtg Options tailpiece,spud coupling and flange for top spud connection. •-BG BioCareTm ADA Handle Control stop has internal siphon-guard protection.Internal seals •-H Handle on Front of Flush Valve are made of chloramine resistant materials. 11-HL 1"[25] Metal Push Button 0 Z6003PL-Aquaflush Plus is furnished as specified above •-HL3 3"[761 Metal Push Button and includeds sweat solder kit, vandal resistant stop •_VC Vandal Resistant Stop Cover cap,and cast wall flange. Complete with a chloramine •-YB Sweat Solder Kit resistant,dual seal diaphragm with a clog resistant by- •_YC Cast Wall Flange Pam - •_YJ Split Ring Pipe Support •-YK Solid Ring Pipe Support 0 - Other Architectural/Engineering Approval ZURN INDUSTRIES,LLC. # COMMERCIAL BRASS OPERATION#5900 ELKIN BUCHANAN DRIVE#SANFORD NC 27330 PHONE.,1-800-9974876 #FAX.•919-775-3541 # WORLD WIDE WEB:WWW.ZURN.COM IN CANADA:ZURN INDUSTRIES LIMITED# 3544 NASHUA DRIVE#MISSISSAUGA, ONTARIO L4VIL2 #PHONE:905-405-8272 FAX.905405-1292 Rev. L Date: 9/21111 AquafiusW'is a registered trademark of Zurn Industries, LLCr Dwg.No.55938 Product No. Z6003 (� VITREOUS CHINA LAVATORY 12-831 / 12-834 / 12-838 MAXWELL" O Lavatory val5elf-Self-Rimming g ava ry Features: • 21" x 17 7/8" Oval Lavatory • 1 Hole (12-831/12-831-CH) • 4" Centers (12-834/12-834-CH) • 8" Centers (12-838/12-838-CH) 000 • Concealed Front Overflow • White, Bone, Biscuit • ADA Compliant Dimensions: O Width " Depth........................................17 7/8" Shipping Weight.................20 Ibs Catalog Numbers: • 12-831/12-834/12-838 Gerber heavyweight ctn. (20/skid) • 12-831-CH/12-834-CH/12-838-CH Catalog#12-834 Shown Trapezoid ctn. O (24/skid) 4" 2 V '/a M4- 33 �, /4 2 .- /e_ 2- L 17 7/8rr 21 " Job Name Date Model Specified Quantity �P� Customer Contractor ® www.gerberonline.com Architect/engineer Because we are committed to continual product improvement,specifications are subject to change without notice. 06/09 q. MAXWELL LAVATORY 12-834 Oval Self-Rimming • � 4 � v 2 3/4 e ® (J) 3/4rr 17 7/s 107/8" s 16 21" '/2 4 2" 7 3/arr 12 3/4 r 111/4 1 If— 8'�I 3/g' H OT X , ~ 3/8" COLD 11/4" WASTE CL 31" FINISHED FLOOR NOTES: IMPORTANT: All dimensions are in inches. Dimensions of fixtures are nominal and may vary within the range of tolerances established by ASME Illustrations may not be drawn Standard A 112.19.2. to scale. VITREOUS CHINA LAVATORY 06/09 I . CAL—MAAY _ lavatory uecK iviount i-aucet aRECfFICATIONS Model(s) LK422L4 PRODUCT SPECIFICATIONS Lavatory Deck Mount Faucet. Faucet has a flow rate of.5 GPM, and is made of Chrome Plated Brass material,with a Ceramic Disc valve. Faucet requires 2 faucet holes. Mounting Type: Deck Mount �� l Special Features: Solid Brass Construction Finish: Chrome(CR) Handle Type: 4"Wristblade Handle " Deck Clearance: 2" Spout Reach: 4-3/4" Spout Height: 5-1/81, Hole Drillings: 2 Material: Chrome Plated Brass Valve Type: Ceramic Disc s� Valve Connection: 1/2"-14 NPSM Flow Rate: .5 GPM Faucet Hole Spread: 4" AMERICAN PRIDE. A LIFETIME TRADITION. Like your family,the Elkay family has values and traditions that Countertop Thickness: 0.0000 endure.For almost a century,Elkay has been a family-owned and Spout Swing Rotation: W operated company,providing thousands of jobs that support our Spout Type: Fixed Spout families and communities. Product Compliance: ADA& ICC A117.1 ASME Al12.18.1/CSA B125.1 NSF 61 NSF 372(lead free) Clean and Care Manual(PDF) Installation Instructions(PDF) Limited Warranty(PDF) m V ` late' (48mm) 4' --(102mm) 6' (152mm) 4-112" (114mm) 5-1/8" (130mm) 3-1/4* (83mm) 2° PART: QTY: 051 mm) PROJECT: 2.1/4" CONTACT: (57mm) DATE: 4-3/41 NOTES: `(121 mm)—' APPROVAL: In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkay.corn for the most current version of Elkay product specfcation sheets. This specification describes an Elkay product with design,quality, and functional benefits to the user. When making a comparison of other producers'offerings,be certain these features are not overlooked. Elkay REV 09282016 2222 Camden Court ©2016 1 1<4,91 4 Onk Rrnnk 11 Finri93 I K4291 4 cnAr.nrtf f + ENLARGED PLAN GEN . NOTES: I . REF. AI .00 FOR GENERAL NOTES 4 DIMENSIONINS CONVENTIONS. 2, REF. A2.05 FOR GEILINS LEGEND AND NOTES ' 5. REF, A4.0 FOR INTERIOR WALL TYPES. 4, KEYFW NOTES RE TO EQUIPMENT AND ACCESSORY M4 SGFfEDULE. / 5, REF. A6.01 F'OR ACCESSORY MOUNTIN6 CODE F VZ ALIGN NEW TO ' RECUIREMENTS. MATCH EXI5TING HEIGHT EXI5TIN6 � IL 15 (S I • ,o • Connect new -----7 I a lavatory drains to i i Connect new lavatory drains existing EOLC �I ® /to existing floor drain vent R 06 O6 I I � I Connect new I I . ' drains to existing •'----• 1 _ V.S. TO TI6HT LINE waste piping I a 14 04 1 I PROV I DE GL.EANOUT 1-1 1 Q 10 Remove existing Ar AND ACCESS PANEL AT 03 aT o9 o r N3 Oe os 12 ___= valves and use h 42° A,F.F. ' water supplies for exlsTlrle wALI / KkLL} 07 I 12 EXISTIN5 G.M.U. - Paw cut area OFF � Extend existing watt ® ICE COPY 19 piping for new toilets 1 p M4 - and urinal I 1 7r5-6:- - � I 1 ■ 10 ---1 A5 V.I MATCH 1D EXISTING • v HEIGHT CITY OF ARLINGTON 1 ENLARGED PLAN ALIGN NEW TO BUILDING DEPARTMENT lqm EXISTIN6 - ENLARGED PLAN -AP PROVED DA /�/ BY Igo CHANW8 AUTHORIZED Received UNLESS APPROVED BY THE BUILDING INSPECTOR OCT 12 2016 EQUIP ENT& OR S-HEOULE MOUNTING ROUGH-IN REG. FURNISW INSTALL TAG I DESCRIPTION MASIS OF DESIGN MANUFACTURER.STYLES PRODUCT NO LOC. ELEC PLMB GAS FJ,C. IPM.C.L N,LC. REMARKS 01 CORNER GUARDS ACROVYN C0-8,STAINLESS STEEL X A. 02 FIRE EXTINGUISHER S CABNET LARSEN.2720 SM.SOLD DOOM ALUM,TRIM SR X 03 LOW FLOW FLOOR MOUNTED TANK SME TO LET REF PLUMBING DRAWINGS(AMERICAN STANDARD F NOT INDICATED) X X 04 WATER CLOSET SEAT REF PLUMBING DRAWINGS(AMERICAN STANDARD F NOT INDICATED) X 05 P.LAM COUNTER 032"A.F.F. COLOR TO BE SELECTED FROM MANUF,STANDARD SELECTION x 08 TOILET PAPER ROLL DISPENSER BOBRICK,8-2890 SM X U 07 TOLETSEATCOVER DISPENSER BOBRICK,B-4221 SM x N 00 SOAP DISPENSER BOBRICK,54112 SM X Z 09 PAPER TOWEL DISPENSER BOBRCK,B-3820 SM X 10 WALL MOUNTED LAV AND DRAIN(W PPE NSUL.) REFERENCE PLUMBING DRAWINGS X x C 11 LAY FAUCET SET REFERENCE PLUMBING DRAWNGS(ELKAY BRAND F NOT INDICATED) X X C 12 FRAMED MIRROR BOBRCK,0-165 24W :L18'MIRROR) X cc 13 COAT HOOK Wf BUMPER BOBRICK B-212/LOCATED ON BACK OF DOOR X D 14 SANRARYNAPKN DISPOSAL BOBRICK.B-270 x 15 TOILET PARTITION MATCH EXISTING PARTITIONS X 0 18 LOW-FLOW URINAL REF PLUMBING DRAWINGS RICAN STANDARD F NOT INDICATED) X X 17 SEISMIC JOINT COVERS MCHAELRQIACOMPANY x 0 18 MSKE78ALL BACKBOARDS PORTER ATHLETIC COMPANY X 19 VOLLEYBALL NET&POSTS PORTER ATHLETIC COMPANY X C) 20 ATHLETIC BLEACHERS x — C GENERAL 1.NOT ALL ITEMS WILL BE TAGGED N DRAWINGS Q rouwrLunLoce7INW, FURNISH/NS7ALLABBREVIATIONS: NOTES: 2.N FRAMED WALL PROVIDE BLOCKING FOR ALL EQUIPMENT PER BACKING PLATE DETAILS R-RECESSED F.LC. FURNISHED&INSTALLED BYCONTRACTOR 3,REFERENCE ACCESSORY MOUNTING DIAGRAMS FOR CODE REOURED MOUNTING HEIGHTS &.caw wcr_.Fruvn F.O,C.L FL•MMHED BYO 44E CONTRACTOR INSTALLED Dr nth. SM- N-LC. NOT N CONTRACT OVMRFURNISHEDAND NSTALLE SPECFIC A. lYPCALAT ALL OUTSDECORNERS ATG.W.B.CON37RUCTpN M-SURFACE MOLN AI REMARKS B. ONE SET EQUALS-1,W 1.42`1-ur R71CiAL C. INSULATE UNDER SINK PIPES PER ADA REQUIREMENTS D.LOCATE HANDLE AT41V A.F.F.PER A.D.A1 t ED A2.CQ .. $ - rr�»>nurmirtumr . uii�rirs / I i CONTINUED 62= tf G A2.01 I I—� `-• GYM. OFFICE ®� /{ / ? ° _ — — A2.01 Pin- IL As V I ►�lA rcv�� AREA - A>g - $ GYM «�STOR /?"151 I t*`6 '} ~ — "' " g SNOT IN N.J .L . , r,5 I L` tee. M o ' roof s s — LL I — — — ql I ralni - o - A 21 02 VB B r — iv j t Bf n r Al v 58 r d pl ICE) t fCa iS t LOBBY ts�_Z. u ® •o —I� DOD E / ` IH AD 4 i - ------- ---------- - - ---- -- 1 Connect to outdoor G A I 1 L a storm water piping D I n 1 I ®, _J L_ N8 - ALT 02 1= GYMNAST TWO rA T1 ,111 I I_- A2 V I I SYM. i r- PR B'-4• A.F.F. _7 B_ A.P.F•_ _ - J - - - fr_ / � I / — EXTERIOR/TALL PER\ ` I r o METAL B8-M. MAN . ALT p 1 rr , I I �0 I 1 - / PLYND. ON INTERIOR a / TO D A.F.F. ' ' 1-5/6' METAL \ 9 I1Dr - - - - --- - - - - - - - 4 5 1 ST �12" O.G�1 /r �A W - I A ' EACH SIDE r i' tl 1' l a A2 V I I ;D a ' fIJJT. � I I i II � �� �` ' �� - REF. 1 /A . Ob FOR COURT AYOUT I e'-o' A.F.F. BLIPS. MANUF. t ,r I r - '►s v1 B'-O' A.P.O. WALL PAD AND COURT 5TR PING CRASH PADS INDICATEDTO E /.• � _ I ' \� X'TENT5 ON ,• 2 I -�- -" '- --- - - - - - - - , 2 COURT LAYOUT PLAN ,l , COLUMN WRAP(M) � A2 VI 8'-O' A.�-F. I A2 VI W-O" A.F.F. N.T.S. 4 I I I 1 A A ' 1D D L--=g ---------- =s'-------------- --5. $. .5. 5. ----JA - --------- --- ----- - ----- ---------------- ------- 28'-0 ' 25'-0. 25'-0" 25'-O"'F e'-6. 25'-0" L 25 -0- 2 150-O" E G Del PLAN GENERAL NOTES: PLAN KEYED NOTES: © , IN CONDUIT FOR BOARD o ,G'-o" A.F,F. I ALT�n1Are +F, y 1. THE GENERAL CONTRACTOR 15 RESPOW21ME FOR THE ACCURATE _ MLA De NT OF THE BUILDING ON THE SITE. VEIIFY ALL ® FRONT LIFT RETRACTABLE BASKETBALL BAC400ARD (BOTH 005 BASED BID) PLAN 5YMB0L5 LEGEND. 0 DIMENSIONS AND EXISTING CONDITIONS PRIOR TO PLAU3404T (MANUAL LIFT) ® RELOCATED GAS METER STANDARD SYMBOLS AND NOTES ON ALOO NOTIFY THE ARCHITECT OF ANY DISOEFANCIeS FOR ® FIXED BASKETBALL BAaWARD ® G' X 6' GONG. STOOP SLOPE FROM BLD6 1 FLOOR PLAN EA C RESOLUTION IN WRITING. ® FURR OUT WALLS AT X BRACING AND PROVIDE 2" OO BASE BID LOCATION FOR DOUBLE DOOR, CONIECT I 1/8" I'-O" M 2. DO NOT SCALE DR/WLhK6. DIMENSIONS SHOWN AIM FROM FACE A EXTERIOR WALL TYPE CRASH PADS ON F.O.WALL REF. COURT STRIPING SIDEWALK TO EXISTING OF MASONRY'; CENTERLINE OF STRUCTURAL GRID OR FAGS OF FOR EXTENTS (IFY STUD. DIMENSIONS INDICATED AS +/-OR V.I.F. ARE ® ®GE OF WXZ55M SLAB RANGE DETAIL INTeR10R FAGS OF WALL IN GYM,-TO HAVE 3/4' APPROXIMATED AND TO BE VERIFIED IN FIELD. DIMENSIONS PLY/C. DOOR TO cEILIN6 THROUGHOUT 53 s EXTERIOR WALL TYPES INDICATED AS CLEAR OR 'CLR' ARE CODE DIHMIONS AND 2/A2.06 INTERIOR PARTITION TYPE REP A4.0 REP. A4.00 FOR INTERIOR PARTITIONS TYPES CQ TAKE PRECEDE1Y_ TO OTHER DIMa6ION5 INDICATED. ® `SURFACE MOUNTED F:E.G. ® PORTABLE FURNISHED LOCATION - D) REFERENCE A2 V5ly IREF. A2.01 FOR ADDITIONAL EXTERIOR WALL INFO S. ALL OUTSIDE GOSd.'13t5 OF G.W.B. TO RECEIVE GCRNBR BEADS ® YRAP ALL COLUMNS,AND B.B. COURT ENDS W/ 2" (OWNER TOEXTE AND INSTALLED) C AND CORNER GUARDS. REF. FINISH SCJHEDULE5 FOR MORE WALL CRASH PAD5 AS INDICATED ON COURT PLAN © B/Al. 1 TO F�ttEdPr SFIOW, REF. SITE PLAN AND FIRE E0TINGUlSUIS CABINET WITH 5K AEG/AI 1.1 AQ PER MANUFAGTURED METAL BUILDING E OFR -1 WALES INFORMATION, (BOTH END OF FULL COURT IF ALT 01 NOT U50) 5/AI.OI II 2A t ION 50 REQUIREMENTS. S. COMPLY W/ HANDLE PER MSTUD KALSL BUILT TO A VALUE OF Ct C 4. CONTRACTOR AND SUBS SHALL.NOT HANG ANYTHING FROM ® INSTALL OCCUPANCY 516N W/ 6RAPHIC9 PER I.B.G., O RAISE GM REF. CIVIL PRANIN66 SECTION SOT REGIUIREMENTS. MOUNT 50 HANDLE [5 © WOOD STUD YVALU WITH EXTERIOR STUCCO CAADDING. CONDUIT, DUCTS OR PIPING. ALL SUSPENDED ITEMS SHALL 'TOTAL OC UPANGY NOT TO EXCEED SOO OCCUPANTS" AT 4B' A.F.F. BUILT TO A VALUE I FORM ION. GE WALL BE HUNG FROM STRUCTURAL ELEMENTS. DUCTS SHALL NOT BE 56GT10N5 FOR MORE INFORMATION. 4 PENETRATED BY ELECTRICAL, FIRE 5UPPIWSION OR ANY ® NEW WALL SHALL NOT HINDER EXISTING ROOF �® KEYED NOTE © METAL STUD WALLS WITH EXTERIOR STUCCO aADDING, 07HM SYSTEM. LADDER OR HATCH, BUILT TO A VALUE OF R-19, REFERENCE WALL 5, GENERAL NOTES LISTED ON THIS PAGE ARE NOT INTENDED TO ® REPLACE MSTIN6 D.S. WITH NEW PIPE TO T16HT o EXISTING WALL ® EXISTING G.M.U. WALL SECTIONS FOR MORE INFORMATION. Dom^& BE AT THEE EXCLUSION OF NOTES LISTED ELSE'FE. THIS LINE, DQ ALT�Z - B" (NOMINAL) G.M.U. PONY WALL w DOCUMENT SET 19 MEANT TO BE COMPLIMENTARY, AND NOTES ( OR ROUGH IN CONDUIT a OUTLET FOR SCORE BOARD NEW WALL -•-•-•-•- I MO RATING REF. ELEVATIONS R SECTIONS FOR EXTENTS /' LISTS-D ON OTHER %l_TS MAY HAVE BEARING/,, CL APPLICATION JACK _ - E METAL STUD WALLS WITH EXTERIOR STUCCO ADDING TO WOW 5HOYN �. - 2 HOUR RATING � BOTH SIDE, FeUR54E WALL SEGTIOHLS FOR MORE +•� INFORMATION SIM. EXTERIOR WALL 'G' Date: 03/11/2026 Permit#: 1169 Permit Date: 10/12/2016 Review Date: 10/12/2016 Permit Type: COMMERCIAL PLUMBING Review Type: COMMERCIAL PLUMBING Target Date: 10/19/2016 Scheduled 00:00 Time: Completed 10/14/2016 Date: Description: There is an RPBA as premise isolation that needs to be replaced it has never been tested and has failed please replace with a new RPBA and a test is required after installation. Gus Review Status: Assigned To: PW-WAT REV Time In: 00:00 Time Out: 00:00 Hours: 0.0 Property Information Parcel#: 31052200103100 ARLINGTON CITY OF ARLINGTON CITY OF 18204 59TH DRIVE NE 18513 59TH AVE NE ARLINGTON, WA 98223 Zoning: 431 Airports & Flying FieldsLot: Block: Date: 03/11/2026 Permit#: 1169 Permit Date: 10/12/2016 Review Date: 10/12/2016 Permit Type: COMMERCIAL PLUMBING Review Type: COMMERCIAL PLUMBING Target Date: 10/19/2016 Scheduled 00:00 Time: Completed 10/13/2016 Date: Description: 1.With these plumbing fixture additions, what will the building fixture count be? Is this fixture count within the existing meter's capacity? X Review Status: Assigned To: PW-ADMIN-GIS Time In: 00:00 Time Out: 00:00 Hours: 0.0 Property Information Parcel#: 31052200103100 ARLINGTON CITY OF ARLINGTON CITY OF 18204 59TH DRIVE NE 18513 59TH AVE NE ARLINGTON, WA 98223 Zoning: 431 Airports &Flying FieldsLot: Block: Date: 03/11/2026 Permit#: 1169 Permit Date: 10/12/2016 Review Date: 10/12/2016 Permit Type: COMMERCIAL PLUMBING Review Type: COMMERCIAL PLUMBING Target Date: 10/19/2016 Scheduled Time: 00:00 Completed Date: 10/12/2016 Description: No issues. FR Review Status: Assigned To: PW-SEW-REV Time In: 00:00 Time Out: 00:00 Hours: 0.0 Property Information Parcel#: 31052200103100 ARLINGTON CITY OF ARLINGTON CITY OF 18204 59TH DRIVE NE 18513 59TH AVE NE ARLINGTON, WA 98223 Zoning: 431 Airports & Flying FieldsLot: Block: Permit#: 1169 Permit Date: 10/12/16 Permit Type: COMMERCIAL PLUMBING Project Name: Boys & Girls Club Applicant Name: Wolfe Plumbing Applicant Address: 17321 Tye Street SE, #B Applicant, City, State, Zip: Monroe,WA 98273 Contact: Mike Annunziata Phone: 360-794-8621 Email: mikea@wolfepi.com Scope of Work: Adding plumbing to commercial addition/alteration Valuation: 20000.00 Square Feet: 0 Number of Stories: 1 Construction Type: Occupancy Group: ID Code: Permit Issued: 10/19/2016 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Launa Black Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 31052200103100 18513 59TH AVE NE ARLINGTON CITY 431 Airports& OF Flying Fields Contractors Contractor Primary Contact Phone Address Contractor Type License License# Wolfe Plumbing 360-794-8621 17321 Tye St SE, CONSTRUCTION Labor&Industries WOLFEP1033CJ #B CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 10/27/2016 C20.BUILDING Approved FINAL Plan Reviews Date Review Type Description Assigned To Review Status 10/12/2016 COMMERCIAL BUILDING PLUMBING COMMERCIAL 1.With these plumbing fixture additions,what will the 10/12/2016 building fixture count be?Is this fixture count within the PW-ADMIN-GIS PLUMBING existing meter's capacity?JK 10/12/2016 COMMERCIAL No issues.FR PW-SEW-REV PLUMBING There is an RPBA as premise isolation that needs to be COMMERCIAL replaced it has never been tested and has failed please 10/12/2016 PLUMBING replace with a new RPBA and a test is required after PW-WAT-REV installation. Gus Fees Fee Description Notes Amount Mechanical Commercial Permit Table 4-7;Per Unit $120.00 Plumbing Plan Review Fees $300.00 Plumbing Base Permit Fee $25.00 Total $445.00 Attached Letters Date Letter Description 10/19/2016 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 10/20/2016 Wolfe Plumbing,Inc Check#100340 Kristin Foster $445.00 Outstanding Balance $0.00 Uploaded Files Date File Name 10/12/2016 1889759-1169 Plan Set.pdf 10/12/2016 1889756-1169 Application.pdf Boys & Girls Club Existing Girl's Restroom New Girl's Restroom Qty. 3 Showers 18 DFU Qty. 4 Water Closet 24 DFU Qty. 2 Water Closet 12 DFU Qty. 3 Sinks 6 DFU Qty. 2 Sinks 4 DFU Total 34 DFU Total 30 DFU Existing Boy's Restroom New Boy's Restroom Qty. 3 Showers 18 DFU Qty. 2 Water Closet 12 DFU Qty. 1 Water Closet 6 DFU Qty. 1 Urinal 4 DFU Qty. 1 Urinal 4 DFU Qty. 3 Sinks 6 DFU Qty. 2 Sinks 4 DFU Total 32 DFU Total 22 DFU