Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
7722 KESTREL CRT_BLD1172_2026
RESIDENTIAL MECHANICAL PERMIT APPLICATION t�N Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:7722 Kestrel Ct Project Description:Replace Gas Furnace and add AC Owner: Carol Morales Address. 7722 Kestrel Ct City: Arlington StateWa Zip Code: 98223 Phone. 360.386.9647 Email:info@blacklionhvac.com Applicant: Brenda @Black Lion Heating & Air Conditioning Address: 11001 118th PI Ne City: Kirkland State WA Zip Code: 98033 Phone. 425-814-3944 Email: info@blacklionhvac.com CONTRACTOR INFORMATION Contractor Name:Black Lion Heating & Air Conditioning Address: 11001 118th PI Ne City: Kirkland StateWa Zip Code: 98033 License Number. BLACKLH873QQ Expiration: 11/17 Phone:425-814-3944 EmaiI:Info@blacklionhvac.com STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 Y. RESIDENTIAL MECHANICAL PERMIT APPLICATION SING Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES 310 ° Furnace (80+) Model # AFUE 80 ❑ Heat Pump Model # AFUE HSPE AC Unit Model # 113 SEER 13 ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: ❑ Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances �ctlerLa'��o�p Applicant Signature: � Date: 10/12/2016 Applicant Printed Name: Brenda Lopez I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 310AAV/310JAV Multipoisei i Sizes 045 thru 155Series E 0 Product Data o STANDARD FEATURES ® • Noise elimination combustion system Q • Four-position furnace:Upflow,Horizontal Right, Ef Q Horizontal Left,Downflow ° Thirteen different vent options ® �E---E • Compact design only 33-1/3 in.(846 mm)tall • Microprocessor based"smart"control center ® Adjustable heating air temperature rise ® Enhanced diagnostics with LED and reflective sight glass, ® ® � non-volatile fault code memory,and self-test feature On-board fuse for transformer protection • Patented blocked-vent safeguard to ensure proper furnace venting ® • Certified to leak 2 percent or less of its nominal air conditioning CFM delivered when pressurized to 1-In.W.C. with all present air inlets,air outlets,and condensate drain Q port(s)sealed. 4 • HYBRID HEAT®Dual Fuel System compatible Al0252 . All models are chimney friendly when used with accessory vent kit The 310AAV/310JAV 4-Way Multipoise Gas Furnace was designed by Bryant dealers for Bryant dealers.Applications are • Twinning in Upflow,Downflow,and Horizontal easy with 4-way Multipoise design, through-the-furnace downflow venting, 13 different venting options, and a design for easy service access. An inner blower door is provided for tighter ' Perfect Light'" Igniter sealing in sensitive applications. The 310AAV/310JAV furnace is approved for use with natural or propane gas, and the 310JAV is • Residential installations eligible for consumer financing approved for use in Low NOx Air Quality Management Districts. through the Comfort Credit Program DIMENSIONS 5.1 n3os1 21/161b] D 1.7 I435J C yy 07M A ACCESSORY m pi9911 6711 11]23] 115/16 S 7/8 [4931 I1485] SUB � 515/16 �.IF 37/16 5/16 AIR FIDW 57/1611433] AIP FLOW 5]/8 0 n�'� AIRFLOW I [ 91 8 A [1384115/16 Ng9n [11M3] �Y I � 14931 OUDFF nil TOPOF CASING OF CASING V V 413/16 01R 07/8 07/8 [12221 [12.71 713/16 D221 "N� m THERMOSTATWIREENTRY 911/16 D133] ACCESSORr JUNCTION BOX G�_� 99/16 [797.8]D45A1 LOCA110N ��� R4331 013/4 117/16 Izsa71 G7',C=nOM � GR Nllt� _ � � 273/4 07/8 273/4 [012.]1 013/4 v04.71 1JWX PROVWON VO4.71 THFJiMOSTATWWENIRY [4461 299/16 07/8 �^ GAS ENTRY vs&71 [22.21 I80.791 I ACCESSOPY — 078 1478 D22] D374 ACCESSOPI' (BOTH SIDES) 0]/8 ACCFSSORRY� — 21A 41 _ 34 VENTNG(S FOR D495] (10.71 BOTTOM REMiN 119.11 NENNNG(5 D1 b] DTH BOITIXA NLET 221/16 1 U39 PULES) 56M D$A] V212J SIDE INLET (BOTH SDES) [7 91 A10271 NOTES: 1.Two additional 7/8—in.(22 mm)diameter holes are located in the top plate. 2.Minimum return—air openings at furnace,based on metal duct.If flex duct is used,see flex duct manufacturer's recommendations for equivalent diameters. a. For 800 CFM-16—in.(406 mm)round or 14 1/2 x 12—in.(368 x 305 mm)rectangle. b. For 1200 CFM-20—in.(508 mm)round or 14 1/2 x 19 1/2—in.(368 x 495 mm)rectangle. c. For 1600 CFM-22—in.(559 mm)round or 14 1/2 x 22 1/16—in.(368 x 560mm)rectangle. d. For airflow requirements above 1800 CFM,see Air Delivery table in Product Data literature for specific use of single side inlets.The use of both side inlets,a combination of 1 side and the bottom,or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM. A C D VENT CABINET WIDTH B TOP& BOTTOM CONNECTION SHIP WT FURNACE SIZE IN(mm) OUTLET WIDTH BOTTOM FLUE INLET WIDTH SIZE LB(KG) IN(mm) COLLAR IN(mm) IN(mm) IN(mm) 024045 14-3/16 (360) 12-9/16 (319) 9-5/16 (237) 12-11/16 (322) 4 (102) 104 (47) 036045 14-3/16 (360) 12-9/16 (319) 9-5/16 (237) 12-11/16 (322) 4 (102) 107 (49) 024070 14-3/16 (360) 12-9/16 (319) 9-5/16 (237) 12-11/16 (322) 4 (102) 111 (50) 036070 14-3/16 (360) 12-9/16 (319) 9-5/16 (237) 12-11/16 (322) 4 (102) 115 (52) 048070 17-1/2 (445) 15-7/8 (403) 11-9/16 (294) 16-1/8 (410) 4 (102) 126 (57) 042090 17-1/2 (445) 15-7/8 (403) 11-9/16 (294) 16-1/8 (410) 4 (102) 127(58) 048090 21 (533) 19-3/8 (492) 13-5/16 (338) 19-1/2 (495) 4 (102) 140 (64) 060090 21 (533) 19-3/8 (492) 13-5/16 (338) 19-1/2 (495) 4 (102) 146 (66) 036110 17-1/2 (445) 15-7/8 (403) 11-9/16 (294) 16-1/8 (410) 4 (102) 135 (61) 048110 21 (533) 19-3/8 (492) 13-5/16 (338) 19-1/2 (495) 4 (102) 146 (66) 066110 21 (533) 19-3/8 (492) 13-5/16 (338) 19-1/2 (495) 4 (102) 152 (69) 048135 21 (533) 19-3/8 (492) 13-5/16 (338) 19-1/2 (495) 4 (102)* 149 (68) 066135 24-1/2 (622) 22-7/8 (581) 15-1/16 (383) 23 (584) 4 (102)* 163 (74) 060155 24-1/2 (622) 22-7/8 (581) 15-1/16 (383) 23 (584) 4 (102)* 170 (77) *135 and 155 size furnaces require a 5 or 6—in. (127 or 152 mm)vent. Use a vent adapter between furnace and vent stack. See Installation Instructions for complete installation requirements. 2 CLEARANCE TO COMBUSTIBLES WARNING INSTALLATION FIRE, EXPLOSION, MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION ASPHYXIATION HAZARD This forced air furnace is This furnace is approved for equipped for use with natural UPFLOW, DOWNFLOW, and Improper adjustment,alteration,service, gas at altitudes 0 - 10,000 ft HORIZONTAL installations. maintenance,or installation can cause (0 - 3,050m). i„ Clearance arrows serious injury or death. An accessorykit, supplied b z54mm) furnace not change with Pp Y � furnace orientation. the manufacturer, shall be used w Read and follow instructions and to convert to propane gas use precautions in User's Information Manual or may be required for some BA o S of provided with this furnace. Installation natural gas applications. �K PEE and service must be performed by a This furnace is for indoor F o\A qualified service agency or the gas installation in a building F� SE R supplier. constructed on site. E F V'°E This furnace may be installed S° R°N �2,V T A CAUTION on combustible flooring in alcove h 11 gm) M" or closet at minimum clearance o Check entire gas assembly for leaks after as indicated by the diagram lighting this appliance. from combustible material. 0" This furnace may be used with t Clearance in inches INSTALLATION a Type B-1 Vent and may be Vent Clearance to combustibles: 1.This furnace must be installed in vented in common with other For Single Wall vents 6 inches(6 po). accordance with the manufacturer's gas fired appliances. For Type B-1 vent type 1 inch(1 po). instructions and local codes. t the MINIMUM INCHES CLEARANCE TO absence of local codes,follow the National Fuel Gas Code ANSI Z223.1 /NFPA54 COMBUSTIBLE CONSTRUCTION or CSA B-149. 1 Gas Installation Code. 2.This furnace must be installed so there are DOWNFLOW POSITIONS: provisions for combustion and ventilation air. See manufacturer's installation t Installation on non-combustible floors only. information provided with this appliance. For Installation on combustible flooring only when installed on special base, Part No. KGASB0201ALL or NAHA01101 SB, Coil Assembly, OPERATION Part No. CAR,CAP,CNPV,CNRV, END4X, ENW4X,WENC,WTNC, This furnace is equipped with manual reset WENW OR WTNW. limit switch(es) in burner compartment to 0 18 inches front clearance required for alcove. protect against overheat conditions that can result from inadequate combustion air * Indicates supply or return sides when furnace is in the horizontal supply or blocked vent conditions. position. Line contact only permissible between lines formed by 1. Do not bypass limit switches. intersections of the Top and two Sides of the furnace jacket, 2. If a limit opens, call a quallified and building joists, studs or framing. I I I I I II II IIII IIIIIIIII I I II IIIII II IIII serviceman to correct the condition and reset limit switch. 336996-101 REV.c A10269 ` DESIGN CERTIFIED- Always Ask For Use of the AHRI Certified TM Mark indicates a `j�1��;��?}r�����,�J manufacturer's participation in the program. For FR T I F�� ® h�l�i•' verification of certification for individual products, go to www.ahridirectory.org. ISO 9001 QMI-SAI Global 3 SPECIFICATIONS UNIT SIZE 024045 036045 024070 036070 048070 042090 048090 RATINGS AND PERFORMANCE Input Btuh* 310JAV Upflow;all 44,000 44,000 66,000 66,000 66,000 88,000 88,000 310AAV Nonweatherized ICS 310JAV Downflow/ 42,000 42,000 63,000 63,000 63,000 84,000 84,000 Horizontal Output Capacity 310JAV Upflow;all 35,000 36,000 53,000 54,000 53,000 71,000 71.000 (Btuh)t 310AAV Nonweatherized ICS 310JAV Downflow/ 34,000 34,000 51,000 51,000 51,000 68,000 68,000 Horizontal AFUEt 80.0 80.0 80.0 80.0 80.0 80.0 80.0 Certified Temperature Rise Range-°F(°C) 30-60 20-50 40-70 30-60 25-55 40-70 30-60 (17-33) (11-28) (22-39) (17-33) (14-30) (22-39) (17-33) Certified External Static Pressure Heat/Cool 0.10/0.50 0.10/0.50 0.12/0.50 0.12/0.50 0.12/0.50 0.15/0.50 0.15/0.50 Heating 920 1250 720 1195 1450 1375 1505 Airflow CFM# Cooling 845 1160 900 1200 1530 1385 1720 Unit Volts-Hertz-Phase 115-60-1 Operating Voltage Range Min-Max 104-127 Maximum Unit Amps 5.4 7.0 5.0 6.8 9.5 8.2 10.0 Maximum Wire Length(Measure 1 Way in Ft(M) 49(14.9) 39(11.8) 52(15.8) 40(12.1) 29(8.8) 34(10.3) 28(8.5) Minimum Wire Size 14 Maximum Fuse or Ckt Bkr Size(Amps)** 15 Transformer(24v) 40va External Control Heating 12va Power Available Cooling 35va Air Conditioning Blower Relay Standard • -• Limit Control SPST Heating Blower Control Solid-State Time Operation Burners(Monoport) 2 2 3 3 3 4 4 Gas Connection Size 1/2-in.NPT GAS CONTROLS Gas Valve(Redundant) Mfr. White-Rodgers Min.inlet pressure 4.5(Natural Gas) (In.W.C.) Max.inlet pressure 13.6(Natural Gas) (In.W.C.) Ignition Device Hot Surface Factory-installed orifice Size 43 BLOWERDATA Direct-Drive Motor HP(PSC) 1/5 1/3 1/5 1/3 1/2 1/3 1/2 Motor Full Load Amps 2.9 5.2 2.9 5.2 7.9 5.2 7.9 RPM(Nominal)-Speeds 1075-3 1075-3 1075-3 1075-3 1075-3 1075-3 1075-3 Blower Wheel Diameter x Width - In.(mm) 10 x 6 10 x 6 10 x 6 10 x 6 11 x 8 10 x 8 10 x 10 (254 x 152) (254 x 152) (254 x 152) (254 x 152) (279 x 203) (254 x 203) (254 x 254) * Gas input ratings are certified for elevations to 2000 ft.(610 M). In USA,For elevations above 2000 ft(610 M),reduce ratings 4 percent for each 1000 ft(305 M)above sea level.Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1-2009 Table F4 or furnace installation instructions. t Capacity in accordance with U.S.Government DOE test procedures. t Airflow shown is for bottom only return-air supply for the as-shipped speed tap.For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required for each return-air supply.An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in.(110 mm)wide, high efficiency media filter. ** Time-delay type is recommended. ICS Isolated Combustion System 4 SPECIFICATIONS (continued) UNIT SIZE 060090 036110 048110 066110 048135 066135 060155 RATINGS AND PERFORMANCE Input Btuh* 310JAV Upflow;all 88,000 110,000 110,000 110,000 132,000 132,000 154,000 310AAV Nonweatherized ICS 310JAV Downflow/ 84,000 105,000 105,000 105,000 126,000 126,000 147,000 Horizontal Output Capacity 310JAV Upflow;all 71,000 89,000 89,000 89,000 107,000 107,000 125,000 (Btuh)t 310AAV Nonweatherized ICS 310JAV Downflow/ 68,000 85,000 85,000 85,000 102,000 102,000 119,000 Horizontal AFUEt 80.0 80.0 80.0 80.0 80.0 80.0 80.0 Certified Temperature Rise Range°F(°C) 25-55 50-80 40-70 30-60 50-80 40-70 45-75 (14-30) (28-44) (22-39) (17-33) (28-44) (22-39) (25-41) Certified External Static Pressure Heat/Cool 0.15/0.50 0.20/0.50 0.20/0.50 0.20/0.80 0.20/0.50 0.20/0.50 0.20/0.50 Airflow CFM# Heating 1990 1335 1515 1900 1525 1850 1790 Cooling 2025 1355 1680 2220 1710 2110 2230 Unit Volts-Hertz-Phase 115-60-1 Operating Voltage Range Min-Max 104-127 Maximum Unit Amps 13.6 8.2 10.2 14.8 10.2 14.4 15.0 Maximum Wire Length(Measure 1 Way in Ft(M)) 32(9.7) 34(10.3) 28(8.5) 30(9.1) 27(8.2) 30(9.1) 29(8.8) Minimum Wire Size 12 14 12 14 11 Maximum Fuse or Ckt Bkr Size(Amps)** 20 15 20 15 20 Transformer(24v) 40va External Control Heating 12va Power Available Cooling 35va Air Conditioning Blower Relay Standard • •• Limit Control SPST Heating Blower Control Solid-State Time Operation Burners(Monoport) 4 5 5 5 6 6 7 Gas Connection Size 1/2-in.NPT GAS CONTROLS Gas Valve(Redundant) Mfr. White-Rodgers Min.inlet pressure 4.5(Natural Gas) (In.W.C.) Max.inlet pressure 13.6(Natural Gas) (In.W.C.) Ignition Device Hot Surface Factory-installed orifice Size 43 BLOWERDATA Direct-Drive Motor HP(PSC) 3/4 1/3 1/2 3/4 1/2 3/4 3/4 Motor Full Load Amps 11.1 5.2 7.9 11.1 7.9 11.1 11.1 RPM(Nominal)-Speeds 1075-3 1075-3 1075-3 1075-3 1075-3 1075-3 1075-3 Blower Wheel Diameter x Width- In.(mm) 11 x 11 10 x 8 10 x 10 11 x 11 10 x 10 11 x 11 11 x 11 (279 x 279) (254 x 203) (254 x 254) (279 x 279) (254 x 254) (279 x 279) (279 x 279) * Gas input ratings are certified for elevations to 2000 ft.(610 M). In USA,for elevations above 2000 ft.(610 M),reduce ratings 4 percent for each 1000 ft. (305 M)above sea level.Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1-2009 Table F4 or furnace installation instructions. t Capacity in accordance with U.S.Government DOE test procedures. # Airflow shown is for bottom only return-air supply for the as-shipped speed tap.For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required for each return-air supply.An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in.(110 mm)wide, high efficiency media filter. ** Time-delay type is recommended. ICS Isolated Combustion System 5 _EE= �JLLULL11 7-A I I II it Ki i i li ii ill G� i i O O •o• SEE NOTES: 1,2,4,7,8,9 SEE NOTES: 1,2,3,4,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 UPFLOW UPFLOW DOWNFLOW A02058 A02059 A02061 uuuul II II Iri I 1 I I O O I O I I I = I e e e e I e e I I I I I I I I I I SEE NOTES:1,2,3,4,5,7,8,9 SEE NOTES: 1,2,3,4,5,7,8,9 SEE NOTES: 1,2,4,5,6,7,8,9 DOWNFLOW DOWNFLOW DOWNFLOW A02060 A02063 A02062 Venting Notes 1. For common vent,vent connector sizing and vent material: United States,latest edition of the National Fuel Gas Code(NFGC),ANSI Z223.1/NFPA 54. 2. Immediately increase to 5-in. (127 mm)vent connector outside furnace casing when 5-in. (127 mm)vent connector required,refer to Note 1. 3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when Downflow Vent Guard is used in downflow position. 4. Type B vent where required,refer to Note 1. 5. 4—in. (102 mm)single wall vent must be used inside furnace casing and the Downflow Vent Guard Kit. 6. Accessory Downflow Vent Guard Kit required in downflow installations with bottom vent configuration. 7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kits for sizing and complete application details. 8. Secure vent connector to furnace elbow with (2)corrosion-resistant sheet metal screws,space approximately 180' apart. 9. Secure all other single wall vent connector joints with (3)corrosion-resistant screws spaced approximately 120' apart. Secure Type B vent connectors per vent connector manufacturer's recommendations. 6 Ili WW o° a. O O �� I 1g II II I 0 o. SEE NOTES: 1,2,4,5,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL RIGHT HORIZONTAL RIGHT A02068 A02070 o' O --- IoI1 II LET i 00, SEE NOTES: 1,2,4,7,8,9 HORIZONTAL RIGHT A02069 111LW W El �\ III III II 1 �4I1 ° I 0 0 o O o O SEE NOTES: 1,2,4,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL LEFT A02064 HORIZONTAL LEFT A02065 LLWWII III I II II�I I i O O O O Lo .1 0 0 SEE NOTES: 1,2,4,5,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT A02066 A02067 7 ACCESSORIES DESCRIPTION PART NO. 024045 036045 024070 036070 048070 042090 048M 060090 036110 048110 066110 048135 066135 060155 FILCABBB0016 X X X X X X X Media Filter Cabinet FILCABBB0020 X X X X X FILCABBB0024 X X FILBBCAR0016 X X X X X X X Cartridge Media Filter FILBBCAR0020 X X X X X FILBBCAR0024 X X EXPXXUNVO016 X X X X X X X EZ Flex Media Filter with End EXPXXUNVO020 X X X X X Caps EXPXXUNVO024 X X EXPXXFIL0016 X X X X X X X Replacement EZ Flex Filter EXPXXFIL0020 X X X X X Media EXPXXFIL0024 X X KGAFR0401B14 X X X X External Bottom Return KGAFR0501 B17 X X X Filter Rack KGAFR0601 B21 X X X X X KGAFR0701B24 X X External Side Return Filter Rack KGAFRO801 SRE X X X X X X X X X X X X X X KGAWF1301UFRt X X X X X X X KGAWF1401UFR X X X X X Unframed Filter,3/4—in. KGAWF1501UFR X X (19 mm) KGAWF1306UFRt X X X X X X X KGAWF1406UFR X X X X X KGAWF1506UFR X X Flue Extension KGAFE0112UPH X X X X X X X X X X X X X X Twinning Kit KGATW0601HSI X X X X X X X X X X X X X X Combustible Floor Base KGASB0201ALL X X X X X X X X X X X X X X Downflow Vent Guard KGBVG0101 DFG X X X X X X X X X X X X X X Vent Extension Kit KGAVE0101 DNH X X X X X X X X X X X X X X KGACA02014FC X X X X X X X X X X X Chimney Adapter Kit KGACA02015FC X X X Natural—to—Propane KGANP4601ALL X X X X X X X X X X X X X X Conversion Kit* Propane—to—Natural KGAPN3901ALL X X X X X X X X X X X X X X Conversion Kit Label Kit KGALB0101 KIT X X X X X X X X X X X X X X Kit Gasket Door KGBAC0101 DGK X X X X X X X X X X X X X X KGAHAO15ON42 KGAHA025ON43 (factory supplied) KGAHA035ON44 KGAHA045ON45 KGAHA055ON46 Gas Orifice Kit(Oty 50) KGAHA1550N47 See Installation Instructions for model,altitude,and heat value usages. KGAHA1650N48 KGAHA065OP54 KGAHA075OP55 KGAHAO85OP56 KGAHA5750125 KGAHA5750130 UV Lights Model UVL Heat/Energy Recovery Ventilator Models HRV or ERV Humidifier Model HUM Electronic or Mechanical Model EACA,EZXCAB,or FILCAB Air Cleaner# * Factory authorized,field installed.Fuel conversion kits are CSA(formerly AGA/CGA)recognized. t Suitable for Side Return Filter Rack. # An external filter is required for all side return—air installations. X=Accessory S=Standard 8 CONTROLS -THERMOSTAT & ZONING DESCRIPTION PART NO. NON-PROGRAMMABLE For use with 1-speed Air Conditioner—deg.F/C,Auto Changeover T6—NAC,T2—NAC For use with 1-speed Heat Pump—deg.F/C,Auto Changeover T6—NHP,T2—NHP* For use with 2-speed Air Conditioner—deg.F/C,Auto Changeover T6—NRH* For use with multi-use/stage configurations—deg.F/C,Auto Changeover/Temperature and Humidity Control T6—PRHt PROGRAMMABLE THERMOSTAT SELECTION For use with 1-speed Air Conditioner—deg.F/C,Auto Changeover,7-Day Programmable T6—PAC For use with 1-speed Heat Pump—deg.F/C,Auto Changeover,7-Day Programmable T6—PHP* For use with 2-speed Air Conditioner—deg.F/C,Auto Changeover,7-Day Programmable T6—PRH* For use with 1-speed Air Conditioner—deg.F/C,5-2 Day Programmable T6—PAC For use with multi-stage applications—deg.F/C,Auto Changeover,7-Day Programmable T2—PHP# For multi-use/stage configurations—deg.F/C,Auto Changeover,7-Day Programmable/Temperature and T6—PRHt Humidity Control ZONING CONTROL SELECTION Zone Perfect 3-Zone kit ZONEBB3ZAC01, _ ZONE13133ZHP01 Zone Perfect Plus 2-Zone kit/Temperature and Humidity Control ZONE131321KIT01-13 Zone Perfect Plus 4-Zone kit/Temperature and Humidity Control ZONEBB4KIT01-13 Zone Perfect Plus 8-Zone kit/Temperature and Humidity Control ZONE131381KIT01-13 * Model HP and 2S thermostat must be field converted to air conditioner operation. t Thermidistat Control can be configured for multiple use and staging.It must be configured for each specific application. t Dual Fuel thermostat is used with furnace and heat pump application. MODEL NUMBER NOMENCLATURE 310 A A V 066 135 E Bryant Type Code Gas Furnace,4—Way Multipoise,80% Fixed—Capacity Model Code A=Standard J=Low NOx Series A B Variations Electrical Supply C A=110 to 125 Volts D E Brand Name Variations A—Common Unit Heating Size 000—None 050—Heating Input Cooling Size 005—Electrical Output 000—None 105—Oil Input 014—14,000 Btuh 037—Boiler Size 018—18,000 Btuh 012—Air 024—24,000 Btuh 060—Humidifiers 9 AIR DELIVERY—CFM (With Filter)* EXTERNAL STATIC PRESSURE(In.W.C.) 310AAV/JAV RETURN-AIR UNIT SIZE SUPPLY SPEED 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Bottom High 1085 1035 975 915 845 770 675 565 390 195 024045 or Med-High 920 875 830 770 710 640 555 440 250 — Side(s) Med-Low 820 775 730 680 620 555 470 360 190 — Bottom High 1440 1375 1305 1240 1160 1070 975 870 730 560 036045 or Med-High 1360 1300 1240 1175 1115 1040 950 850 725 575 Side(s) Med-Low 1250 1210 1160 1100 1040 965 885 790 670 520 Bottom High 1030 1010 980 945 900 845 775 680 490 335 024070 or Med-High 835 815 790 760 720 675 610 490 375 265 Side(s) Med-Low 725 700 675 645 600 555 475 390 300 1 — Bottom High 1425 1375 1320 1265 1200 1125 1035 940 830 655 036070 or Med-High 1320 1280 1240 1205 1140 1075 995 905 790 620 Side(s) Med-Low 1200 1175 1145 1105 1050 990 920 840 725 555 Bottom High 1805 1740 1670 1600 1530 1445 1360 1280 1180 1075 048070 or Med-High 1630 1585 1530 1470 1405 1330 1255 1170 1080 990 Side(s) Med-Low 1460 1420 1385 1325 1280 1220 1155 1080 995 910 Bottom High 1650 1600 1535 1465 1385 1285 1175 1055 895 645 042090 or Med-High 1515 1485 1440 1380 1300 1220 1115 990 830 600 Side(s) Med-Low 1385 1360 1320 1260 1195 1120 1025 915 710 565 Bottom High 2060 1985 1915 1820 1720 1610 1490 1340 1135 925 048090 or Med-High 1790 1765 1715 1645 1560 1470 1345 1195 1010 820 Side(s) Med-Low 1505 1505 1480 1440 1375 1300 1190 1045 890 740 Bottom High 2405 2310 2220 2130 2025 1920 1790 1660 1530 1350 Only Med-High 2225 2155 2080 1995 1895 1785 1675 1565 1420 1260 Med-Low 2020 1955 1880 1805 1730 1630 1535 1420 1275 1135 Both Sides High 2530 2450 2365 2270 2165 2065 1940 1805 1670 1505 060090 on Med-High 2285 2215 2150 2075 1985 1890 1780 1660 1525 1360 Side&Bottom Med-Low 1995 1945 1900 1840 1770 1685 1600 1480 1 1350 1180 High 2475 2395 2300 2200 2090 1985 1865 1730 1585 1425 1 Side Only Med-High 2260 2190 2110 2035 1940 1845 1735 1620 1475 1325 Med-Low 1950 1910 1855 1795 1730 1650 1555 1445 1310 1150 Bottom High 1625 1575 1515 1445 1355 1260 1165 990 785 — 036110 or Med-High 1510 1470 1415 1355 1285 1185 1070 890 725 — Side(s) Med-Low 1360 1335 1295 1250 1180 1100 985 810 Bottom High 2035 1965 1880 1790 1680 1495 1365 1215 1075 875 048110 or Med-High 1745 1710 1650 1560 1450 1340 1205 1090 955 750 Side(s) Med-Low 1530 1515 1470 1400 1310 1215 1095 990 830 670 Bottom High 2530 2470 2400 2320 2220 2115 2000 1865 1730 1590 Only Med-High 2230 2205 2165 2110 2035 1950 1855 1740 1615 1485 Med-Low 1920 1900 1880 1845 1 1795 1730 1 1650 1555 1460 1 1340 Both Sides High 2415 2350 2250 2145 2015 1875 1715 1560 066110 or Side&Bottom Med-High 2235 2200 2155 2100 2040 1955 1850 1740 1595 1470 High 2540 2495 2430 2355 2265 2175 2065 1935 1785 1650 1 Side Only Med-High 2125 2120 2105 2060 2010 1940 1840 1730 1615 1485 Med-Low 1790 1795 1790 1765 1720 1650 1585 1500 1390 1280 Bottom High 2090 2010 1930 1835 1710 1590 1470 1335 1025 835 048135 or Med-High 1790 1755 1705 1640 1550 1465 1360 1210 945 785 Side(s) Med-Low 1545 1520 1500 1450 1380 1315 1215 1005 855 670 Bottom High 2485 2400 2310 2215 2110 2000 1880 1725 1535 1355 Only Med-High 2195 2150 2090 2000 1920 1825 1720 1565 1405 1255 Med-Low 1880 1850 1820 1780 1715 1635 1540 1415 1290 1160 Both Sides High 2385 2305 2195 2085 1960 1825 1670 1465 066135 on Med-High 2180 2145 2060 2010 1945 1865 1765 1660 1515 1325 Side&Bottom Med-Low 1880 1850 1820 1780 1715 1635 1540 1415 1290 1160 High 2245 2155 2055 1940 1825 1695 1555 1385 1 Side Only Med-High 2135 2085 2035 1975 1895 1795 1685 1565 1445 1265 Med-Low 1880 1850 1820 1780 1715 1635 1540 1415 1290 1160 Bottom High 2465 2430 2375 2305 2230 2110 2000 1865 1725 1545 Only Med-High 2115 2105 2075 2030 1980 1910 1830 1725 1590 1425 Med-Low 1800 1790 1770 1735 1 1695 1640 1570 1465 1345 1225 Both Sides High 2375 2285 2200 2105 1995 1870 1730 1570 060155 on Med-High 2155 2135 2095 2040 1975 1895 1790 1685 1550 1400 Side&Bottom Med-Low 1800 1790 1770 1735 1695 1640 1570 1465 1345 1225 High 2260 2180 2085 1975 1865 1740 1605 1455 1 Side Only Med-High 2140 2095 2040 1975 1890 1810 1705 1595 1480 1325 Med-Low 1800 1790 1770 1735 1695 1 1640 1570 1465 1345 1225 * A filter is required for each return—air supply.Airflow performance includes 3/4 in.(19 mm)washable filter media such as contained in factory—authorized accessory filter rack.To determine airflow performance without this filter,assume an additional.1 available external static pressure. Indicates unstable operating conditions. 10 11 GUIDE SPECIFICATIONS Gas Furnace Inducer Motor 310AAV/JAV Inducer motor shall be soft mounted to reduce vibration General transmission. Draft Safeguard Switch SYSTEM DESCRIPTION Draft Safeguard Switch (blocked vent safeguard) shall Furnish a fixed capacity gas-fired be factory installed to reduce the possibility of vent gas furnace for use with natural gas or propane (factory infiltration due to a blocked or restricted vent pipe. authorized conversion kit required for propane); furnish Heat Exchangers cold air return plenum. Heat exchangers shall be a 4-Pass 20 gage aluminized QUALITY ASSURANCE steel of fold-and-crimp sectional design when applied Unit will be designed, tested and constructed to the operating under negative pressure. current ANSI Z 21.47/CSA 2.3 design standard for Controls gas-fired central furnaces. Control shall include a micro-processor non-volatile Unit will be 3rd party certified by CSA to the current memory based integrated electronic control board with at ANSI Z 21.47/CSA 2.3 design standard for gas-fired least 11 service troubleshooting codes displayed via central furnaces. enhanced flashing LED diagnostic light on the control, a Unit will carry the CSA Blue Star® label. self-test feature that checks all major functions of the Unit efficiency testing will be performed per the current furnace within one minute, and a replaceable DOE test procedure as listed in the Federal Register. automotive-type circuit protection fuse. Multiple Unit will be certified for capacity and efficiency and operational settings available including, separate blower listed in the latest AHRI Consumer's Directory of speeds for heating, cooling, and continuous fan. Certified Efficiency Ratings. Continuous fan speed may be adjusted from the Unit shall carry the current Federal Trade Commission thermostat. Cooling airflow will be selectable between 350 Energy Guide efficiency label. or 400 CFM per ton of air conditioning. DELIVERY,STORAGE AND HANDLING OPERATING CHARACTERISTICS Unit shall be shipped as single package only and is Heating Capacity shall be Btuh input; stored and handled per unit manufacturer's Btuh output capacity. recommendations. Fuel Gas Efficiency shall be 80%AFUE. WARRANTY(for inclusion by specifying engineer) Air delivery shall be CFM minimum at U.S. and Canada only. Warranty certificate available 0.50 In. W.C. external static pressure. upon request. Dimensions shall be: depth in. (mm); Products width in. (mm); height in. (mm) EQUIPMENT (casing only). Height shall be in. (mm) with A/C coil and in. (mm) overall with Components shall include: slow-opening gas valve to plenum. reduce ignition noise, regulate gas flow, with electric ELECTRICAL REQUIREMENTS switch gas shut-off; flame proving sensor, hot surface Electrical supply shall be 115 volts, 60 Hz, igniter, pressure switch assembly, flame rollout switch, single-phase (nominal). Minimum wire size shall blower and inducer assembly, 40va transformer; be AWG; maximum fuse size or circuit breaker low-voltage(heating)(heating/cooling)thermostat. shall be Amps. Blower Wheel and Blower Motor SPECIAL FEATURES Galvanized blower wheel shall be centrifugal type, Refer to section of the product data sheet identifying statically and dynamically balanced. Blower motor of PSC accessories and descriptions for specific features and type shall be permanently lubricated with sealed bearings, available enhancements. of hp, and shall be multiple-speed direct drive. Blower motor shall be soft mounted to the blower scroll to reduce vibration transmission. Filters Furnace may have reusable-type filters. Filter shall be in(x) in. (mm). Casing Casing shall be of .030 in. (.76 mm) thickness minimum,pre-painted galvanized steel. ©2010 Bryant Heating&Cooling Systems a 7310 W.Morris St.a Indianapolis,IN 46231 Printed in U.S.A. Edition Date:09/10 Catalog No. PDS31 OA.45.6 Manufacturer reserves the right to discontinue,or change at any time,specifications or designs without notice and without incurring obligations. Replaces:PDS 310A.45.5 12 CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:7722 Kestrel Ct Permit#: 1172 Parcel#:00809200002500 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:FAULKINBURY BRIAN/MORALES Name:Black Lion Heating and Air Conditioning Name:Black Lion Heating and Air Conditioning CAROLINA Address:7722 KESTREL CRT Address:1100 1 118th Place NE Address: 11001 118th Place NE City,State Zip:ARLINGTON,WA 98223-5956 City,State Zip:Kirikland,WA 98033 City,State Zip:Kirkland,WA 98033 Phone: Phone:425-814-3944 Phone:425-814-3944 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Black Lion Heating and Air Conditioning Name: Address: 11001 118th Place NE Address: City,State,Zip:Kirkland,WA 98033 City,State,Zip: Phone:425-814-3944 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City o ton must be reported on your sales tax D form and coded City of Arlington#3101. Signature Print Name Date Released By Date CONDITIONS Bryant Furnace 31 OAAV Series E/Bryant AC 113A, SEER 13 - A " concrete pad with seismic bracing attached to pad; electrical disconnect is required; lines shall be insulated-use of adhesive tapes are not permitted. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/13/2016 A/C Unit $25.00 10/13/2016 Furnace $25.00 10/13/2016 Mechanical Permit Base Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 ID PHONE; (360) 403-3551 BUILDING PERMIT Address:7722 Kestrel Ct Permit#: 1172 Parcel#:00809200002500 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:FAULKINBURY BRIAN/MORALES Name:Black Lion Heating and Air Conditioning Name:Black Lion Heating and Air Conditioning CAROLINA Address:7722 KESTREL CRT Address:1100 1 118th Place NE Address: 11001 118th Place NE City,State Zip:ARLINGTON,WA 98223-5956 City,State Zip:Kirikland,WA 98033 City,State Zip:Kirkland,WA 98033 Phone: Phone:425-814-3944 Phone:425-814-3944 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Black Lion Heating and Air Conditioning Name: Address: 11001 118th Place NE Address: City,State,Zip:Kirkland,WA 98033 City,State,Zip: Phone:425-814-3944 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City o ton must be reported on your sales tax retur form and coded City of Arlington#3101. Signature Print Name Date Released By Date CONDITIONS Bryant Furnace 310AAV Series E/Bryant AC 113A, SEER 13 - A 3" concrete pad with seismic bracing attached to pad; electrical disconnect is required; lines shall be insulated -use of adhesive tapes are not permitted. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/13/2016 A/C Unit $25.00 10/13/2016 Furnace $25.00 10/13/2016 Mechanical Permit Base Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon ;:. I I I 1 `tq. ref RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:7722 Kestrel Ct Project Description:Replace Gas Furnace and add AC Owner: Carol Morales Address: 7722 Kestrel Ct City:Arlington StateYVa Zip Code: 98223 Phone: 360.386.9647 Email:info@blacklionhvac.com Applicant: Brenda @Black Lion Heating & Air Conditioning Address: 11001 118th PI Ne _ City: Kirkland StateyVA Zip Code: 98033 Phone: 425-814-3944 Email: info@blacklionhvac.com CONTRACTOR INFORMATION Contractor Name:Black Lion Heating & Air Conditioning Address: 11001 118th PI Ne City: Kirkland StateWa Zip Code: 98033 License Number:BLACKLH873QQ Expiration: 11/17 Phone:425-814-3944 Email:lnfo@blacklionhvac.com Received STAFF USE ON OCT 12 2016 Permit#: Accepted by: Date: 6/16LP Page 1 of 2 5 a�� a,. .� r T RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223 • Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES 0 ( Furnace (80+) Model #3 0 AFUE80% ❑ Heat Pump Model # AFUE HSPE L-4 AC Unit Model # 113 SEER 13 ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance U) Other Gas Piping Information Not Applicable: ❑ Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: Date: 10/12/2016 Applicant Printed Name: Brenda Lopez I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 1 I 10/12/2016 BLACK LION HEATING&A/C LLC (Search L&I 1-Z f flip \IV 1_:t 1 Safety&Health Claims Insurernce Workplace Rights Trades & Licensing Washington State Department of " Labor & Industries BLACK LION HEATING &A/C LLC Owner or tradesperson 11001 118th PI NE Principals KIRKLAND,WA 98033 4-3944 BURGE,JASON KING KING County ROBERT, PARTNER/MEMBER WARD,BENJAMIN PATRICK,PARTNER/MEMBER BURGE,JASON ROBERT, MANAGER BURGE,JASON ROBERT,AGENT Doing business as BLACK LION HEATING&A/C LLC WA UBI No. Business type 603 615 990 Limited Liability Company Governing persons BENJAMIN P WARD JASON R BURGE; License Verify the contractor's active registration/license!certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. BLACKLH87300 Effective—expiration 11/18/2013—11/18/2017 Bond Hartford Fire Ins Co $12,000.00 Bond account no. 52BSBHF4778 Received by L&I Effective date 06/24/2016 07/01/2016 Expiration date Until Canceled WESTERN NATIONAL MUTUAL INS $12,000.00 Bond account no. 22309 Received by L&I Effective date 11/24/2014 11/13/2014 Expiration date Help us improve hops://secure.ini.wa.gov/verify/Detaii.aspx?UBI=603615990&LIC=BLACKLH873QQ&SAW= 1/2 10/12/2016 BLACK LION HEATING&A/C LLC Until Canceled Bond history Insurance Federated Mutual Ins Co $1,000,000.00 Policy no. 980726 Received by L&I Effective date 06/24/2016 05/31/2016 Expiration date 05/31/2017 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Recently opened account. 525,786-01 No premiums due yet. Doing business as BLACK LION HEATING&AIR CO Estimated workers reported N/A L&I account representative T1/JAN BENTLEY(360)902-4652-Email:STR02350ni.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. ©Washington State Dept,of Labor&Industries.Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.ini.wa.govtverify/Detail.aspx?UBI=603615990&LIC=BLACKLH873QQ&SAW= 212 I I . . 4-Way Multipoise Induccul Combustion Gas Furnace Series E 1=0 Product Data -- STANDARD FEATURES • Noise elimination combustion system 0 • Four-position furnace:Upflow,Horizontal Right, ®®®� Horizontal Left,Downflow ®® Thirteen different vent options ® • Compact design only 33-113 in.(846 mm)tall • Microprocessor based"smart"control center Adjustable heating air temperature rise ' Enhanced diagnostics with LED and reflective sight glass, 1 non-volatile fault code memory,and self-test feature On-board fuse for transformer protection • Patented blocked-vent safeguard to ensure proper furnace venting • Certified to leak 2 percent or less of its nominal air conditioning CFM delivered when pressurized to 1-In.W.C. with all present air inlets,air outlets,and condensate drain port(s)sealed. 4 • HYBRID HEAT®Dual Fuel System compatible Al0252 . All models are chimney friendly when used with accessory vent kit The 310AAV/310JAV 4-Way Multipoise Gas Furnace was designed by Bryant dealers for Bryant dealers.Applications are • Twinning in Upflow,Downflow,and Horizontal easy with 4-way Multipoise design, through-the-furnace downflow venting, 13 different venting options, and a design for . perfect Light- Igniter easy service access. An inner blower door is provided for tighter sealing in sensitive applications. The 310AAV/310JAV furnace is approved for use with natural or propane gas, and the 310JAV is • Residential installations eligible for consumer financing approved for use in Low NOx Air Quality Management Districts. through the Comfort Credit Program Received &T 12 2016 DIMENSIONS a, n/os /ma mA wA c 4A 11llla u f)A n�f�� Q N•A MNOW n�naA MIIOW /1YIa ffM • A /7M n , MAOW /$7A / I,YA+ r niff n/aq I amEr iv,•dfw TL.QUs.n ama nA oA nyZ P+/APUAK1Oltot CCU aN/ �� OVA/11Aa /lA — — a®]M LOMM �+cGl p,Ay nvl �I „fin. Dftn pWA — — WAN G�T�C WaT ltl[I M A/N 11fAYNGf1rlOIIIO� �Ky (Aj-4 — ooan bf1111 / W la+n .J." I o A I I II I pp�M — F ti"A ]li al y/ �i A torlaAitE'r n= -14 Q10nEn/. + - 1 nL0 AAA n1n/ — WE n/ul A10271 NOTES: 1.Two additional 7/8—in.(22 mm)diameter holes are located in the top plate. 2.Minimum return—air openings at furnace,based on metal duct.If flex duct is used,see flex duct manufacturer's recommendations for equivalent diameters. a. For 800 CFM-16—in.(406 mm)round or 14 1/2 x 12—in.(368 x 305 mm)rectangle. b. For 1200 CFM-20—in.(508 mm)round or 14 1/2 x 19 1/2—in.(368 x 495 mm)rectangle. c. For 1600 CFM-22—in.(559 mm)round or 14 1/2 x 22 1/16—in.(368 x 560mm)rectangle. d. For airflow requirements above 1800 CFM,see Air Delivery table in Product Data literature for specific use of single side inlets.The use of both side inlets,a combination of 1 side and the bottom,or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM. A I C D VENT CABINET WIDTH B TOP A BOTTOM CONNECTION SHIP WT FURNACE SIZE IN(mm) OUTLET WIDTH BOTTOM FLUE INLET WIDTH SIZE LB(KG) IN(mm) COLLAR IN(mm) IN(mm) IN(mm) 024045 14-3/16 (360) 12-9/16 (319) 9-5/16 (237) 12-11/16 (322) 4 (102) 104 (47) 036045 14-3/16 (360) 12-9/16 (319) 9-5/16 (237) 12-11/16 (322) 4 (102) 107 (49) 024070 14-3/16 (360) 12-9/16 (319) 9-5/16 (237) 12-11/16 (322) 4 (102) 111 (50) 036070 14-3/16 (360) 12-9/16 (319) 9-5/16 (237) 12-11/16 (322) 4 (102) 115 (52) 048070 17-1/2 (445) 15-7/8 (403) 11-9/16 (294) 16-1/8 (410) 4 (102) 126 (57) 042090 17-1/2 (445) 15-7/8 (403) 11-9/16 (294) 16-1/8 (410) 4 (102) 127(58) 048090 21 (533) 19-3/8 (492) 13-5/16 (336) 19-1/2 (495) 4 (102) 140 (64) 060090 21 (533) 19-3/8 (492) 13-5/16 (338) 19-1/2 (495) 4 (102) 146 (66) 036110 17-1/2 (445) 15-7/8 (403) 11-9/16 (294) 16-1/8 (410) 4 (102) 135 (61) 048110 21 (533) 19-3/8 (492) 13-5/16 (338) 19-1/2 (495) 4 (102) 146 (66) 066110 21 (533) 19-3/8 (492) 13-5/16 (338) 19-1/2 (495) 4 (102) 152 (69) 048135 21 (533) 19-3/8 (492) 13-5/16 (338) 19-1/2 (495) 4 (102)* 149 (68) 066135 24-1/2 (622) 22-7/8 (581) 15-1/16 (383) 23 (584) 4 (102)* 163 (74) 060155 24-1/2 (622) 22-7/8 (581) 15-1/16 (383) 23 (584) 4 (102)* 170 (77) •135 and 166 size furnaces require a 5 or 6—in. (127 or 152 mm)vent Use a vent adapter between furnace and vent stack. See Installation Instructions for complete installation requirements. 2 I 1 CLEARANCE TO COMBUSTIBLES WARNING INSTALLATION pPLQW N, MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION ASPHYXIA110N HAZARD This forced air furnace is This furnace is approved for equipped for use with natural UPFLOW, DOWNFLOW, and Improper adjustment,alteration,service, HORIZONTAL installations. gas at altitudes 0- 10,000 ft maintenance,or installation can cause (0-3,050m). Clearance arrows serious Injury death. ,, do not change with 1 ry or An accessory kit, supplied by M furnace orientation. the manufacturer, shall be used W Read and follow instructions and to convert to propane gas use a precautions in Users Information Manual or may be required for some BA provided with this furnace. Installation natural gas applications. GK G� and service must be performed by a This furnace is for indoor qualified service agency or the gas installation in a building Flo 'ER supplier. constructed on site. E This furnace may be installed 9,o R0"T A CAUTION on combustible flooring in alcove ' �" c,,T or closet at minimum clearance o 0 Check entire gas assembly for leaks after as indicated by the diagram lighting this appliance. from combustible material. a" This furnace may be used with t Clearance in inches INSTALLATION a Type B-1 Vent and may be VentClearancetocombustibles: _ 7Fuel rnace must be installed in vented in common with other For Single Wall vents 6 inches(6 po). ance with the manufacturer's gas fired appliances. For Type B-1 vent type 1 inch(1 po). tions and local codes. In the ce of local codes,follow the National MINIMUM INCHES CLEARANCE TO as Code ANSI Z223.1 /NFPA54 COMBUSTIBLE CONSTRUCTION or CSA B-149. 1 Gas Installation Code. 2.This furnace must be installed so there are DOWNFLOW POSITIONS: provisions for combustion and ventilation air. See manufacturer's installation t Installation on non-combustible floors only. information provided with this appliance. For Installation on combustible flooring only when installed on special base, Part No.KGASB0201ALL or NAHA01101 SB, Coil Assembly, OPERATION Part No.CAR,CAP,CNPV,CNRV,END4X,ENW4X,WENC,WTNC, This furnace is equipped with manual reset WENW OR WTNW. limit switch(es)in burner compartment to 0 18 inches front clearance required for alcove. protect against overheat conditions that can result from inadequate combustion air * Indicates supply or return sides when furnace is in the horizontal supply or blocked vent conditions. position. Line contact only permissible between lines formed by 1. Do not bypass limit switches. intersections of the Top and two Sides of the furnace jacket, 2. If a limit opens, call a quallified and building joists,studs or framing. wIIIIIl1A III IIIIII�IIIIIIIIIII� serviceman to correct the condition and reset limit switch. 336996-101 REV.C A10269 • �E S I GN Always Ask For `a •rr,�}li;Y Use of the AHRI Certified TM Mark indicates a All 1I;,�)ls!`r����) manufacturer's participation in the program For verification of certification for individual products, ISO 9001 go to www ahridirectory.org. UMI-"Global 3 I i. SPECIFICATIONS UNIT SIZE 024045 036045 024070 036070 048070 042090 048090 RATINGS AND PERFORMANCE Input Btuh* 310JAV Upflow;all 44,000 44,000 66,000 66,000 66,000 88,000 88,000 310AAV Nonweatherized ICS 310JAV Downflow/ 42,000 42,000 63,000 63,000 63,000 84,000 84,000 Horizontal Output Capacity 310JAV Upflow;all 35,000 36,000 53,000 54,000 53,000 71,000 71.000 (Btuh)t 310AAV Nonweatherized ICS 310JAV Downflow/ 34,000 34,000 51,000 51,000 51,000 68,000 66,000 Horizontal AFUEt 80.0 80.0 80.0 80.0 80.0 80.0 80.0 Certified Temperature Rise Range-°F(°C) 30-60 20-50 40-70 30-60 25-55 40-70 30-60 (17-33) (11-28) (22-39) (17-33) (14-30) (22-39) (17-33) Certified External Static Pressure Heat/Cool 0.10/0.50 0.10/0.50 0.12/0.50 0.12/0.50 0.12/0.50 0.15/0.50 0.15/0.50 Heating 920 1250 720 1195 1450 1375 1505 Airflow CFM# Cooling 845 1160 900 1200 1530 1385 1720 ELECTRICAL Unit Volts-Hertz-Phase 115-60-1 Operating Voltage Range Min-Max 104-127 Maximum Unit Amps 5.4 7.0 5.0 6.8 9.5 8.2 10.0 Maximum Wire Length(Measure 1 Way in Ft(M) 49(14.9) 39(11.8) 52(15.8) 40(12.1) 29(8.8) 34(10.3) 28(8.5) Minimum Wire Size 14 Maximum Fuse or Ckt Bkr Size(Amps)** 15 Transformer(24v) 40va External Control Heating 12va Power Available Cooling 35va Air Conditioning Blower Relay Standard CONTROLS Limit Control SPST Heating Blower Control Solid-State Time Operation Burners(Monoport) 2 2 3 3 3 4 4 Gas Connection Size 1/2-in.NPT GAS CONTROLS Gas Valve(Redundant) Mfr. White-Rodgers Min.inlet pressure 4.5(Natural Gas) (In.W.C.) Max.inlet pressure 13.6(Natural Gas) (In.W.C.) Ignition Device Hot Surface Factory-installed orifice Size 43 BLOWER Direct-Drive Motor HP(PSC) 1/5 1/3 1/5 1/3 1/2 1/3 1/2 Motor Full Load Amps 2.9 5.2 2.9 5.2 7.9 5.2 7.9 RPM(Nominal)-Speeds 1075-3 1075-3 1075-3 1075-3 1075-3 1075-3 1075-3 Blower Wheel Diameter x Width -In.(mm) 10 x 6 10 x 6 10 x 6 10 x 6 11 x 8 10 x 8 10 x 10 (254 x 152) (254 x 152) (254 x 152) (254 x 152) (279 x 203) (254 x 203) (254 x 254) * Gas input ratings are certified for elevations to 2000 ft.(610 M). In USA,For elevations above 2000 ft(610 M),reduce ratings 4 percent for each 1000 ft(305 M)above sea level.Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1-2009 Table F4 or furnace installation instructions. t Capacity in accordance with U.S.Government DOE test procedures, t Airflow shown is for bottom only return-air supply for the as-shipped speed tap.For air delivery above 1800 CFM,see Air Delivery table for other options A filter is required for each return-air supply.An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in-(110 mm)wide, high efficiency media filter. ** Time-delay type is recommended. ICS Isolated Combustion System 4 i M SPECIFICATIONS (continued) UNIT SIZE 080090 036110 048110 066110 048135 066135 060155 PERFORMANCERATINGS AND Input Btuh* 310JAV Upflow;all 68,000 110,000 110,000 110,000 132,000 132,000 154,000 310AAV Nonweatherized ICS 310JAV Downflow/ 84,000 105,000 105,000 105,000 126,000 126,000 147,000 Horizontal Output Capacity 310JAV Upflow;all 71,000 89,000 89,000 89,000 107,000 107,000 125,000 (Btuh)t 310AAV Nonweatherized ICS 310JAV Downflow/ 68,000 85,000 85,000 85,000 102,000 102,000 119,000 Horizontal AFUEt 80.0 80.0 80.0 80.0 80.0 80.0 80.0 Certified Temperature Rise Range°F(°C) 25-55 50-80 40-70 30-60 50-80 40-70 45-75 (14-30) (28-44) (22-39) (17-33) (28-44) (22-39) (25-41) Certified External Static Pressure Heat/Cool 0.15/0.50 0.20/0,50 0.20/0.50 0.20/0.80 0 20/0.50 0.20/0.50 0.20/0.50 Airflow CFM$ Heating 1990 1335 1515 1900 1525 1850 1790 Cooling 2025 1355 1680 2220 1710 2110 2230 ELECTRICAL Unit Volts-Hertz-Phase 115-60-1 Operating Voltage Range Min-Max 104-127 Maximum Unit Amps 13.6 8.2 10.2 14.8 10.2 14.4 15.0 Maximum Wire Length(Measure 1 Way in Ft(M)) 32(9.7) 34(10.3) 28(8.5) 30(9.1) 27(8.2) 30(9.1) 29(8.8) Minimum Wire Size 12 14 12 14 11 Maximum Fuse or Ckt Bkr Size(Amps)** 20 15 20 15 20 Transformer(24v) 40va External Control Heating 12va Power Available Cooling 35va Air Conditioning Blower Relay Standard CONTROLS Limit Control SPST Heating Blower Control Solid-State Time Operation Burners(Monoport) 4 5 5 5 6 6 7 Gas Connection Size 1/2-in.NPT GAS CONTROLS Gas Valve(Redundant) Mfr. White-Rodgers Min.inlet pressure 4.5(Natural Gas) (In.W.C.) Max.inlet pressure 13.6(Natural Gas) (In.W.C.) Ignition Device Hot Surface Factory-installed orifice Size 43 BLOWERDATA Direct-Drive Motor HP(PSC) 3/4 1/3 1/2 3/4 1/2 3/4 3/4 Motor Full Load Amps 11.1 5.2 7.9 11.1 7.9 11 1 11.1 RPM(Nominal)-Speeds 1075-3 1075-3 1075-3 1075-3 1075-3 1075-3 1075-3 Blower Wheel Diameter x Width-In.(mm) 11 x 11 10 x 8 10 x 10 11 x 11 10 x 10 11 x 11 11 x 11 (279 x 279) (254 x 203) (254 x 254) (279 x 279) 1 (254 x 254) (279 x 279) (279 x 279) * Gas input ratings are certified for elevations to 2000 ft.(610 M) In USA,for elevations above 2000 ft.(610 M),reduce ratings 4 percent for each 1000 ft. (305 M)above sea level.Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1-2009 Table F4 or furnace installation instructions. t Capacity in accordance with U S Government DOE test procedures. $ Airflow shown is for bottom only return-air supply for the as-shipped speed tap For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required for each return-air supply An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in.(110 mm)wide, high efficiency media filter. ** Time-delay type is recommended. ICS Isolated Combustion System 5 I .. i c� —J, O •0. _ O O •O• SEE NOTES: 1,2,4,7,8,9 SEE NOTES:1,2,3,4,7,8,9 SEE NOTES:1,2,4,5,7,8,9 UPFLOW UPFLOW DOWNFLOW A02056 A02059 A02061 ll LLLLtJ 1 1� I 1 I I I _ 1 I I I 1 SEE NOTES:1,2,3,4,5,7,8,9 SEE NOTES:1,2,3,4,5,7,8,9 SEE NOTES:1,2,4,5,6,7,8,9 DOWNFLOW DOWNFLOW DOWNFLOW A02060 A02063 A02062 Venting Notes 1. For common vent,vent connector sizing and vent material:United States,latest edition of the National Fuel Gas Code(NFGC),ANSI Z223.1/NFPA 54. 2. Immediately increase to 5-in.(127 mm)vent connector outside furnace casing when 5-in.(127 mm)vent connector required,refer to Note 1. 3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when Downflow Vent Guard is used in downflow position. 4. Type B vent where required,refer to Note 1. 5. 4—in.(102 mm)single wall vent must be used inside furnace casing and the Downflow Vent Guard Kit. 6. Accessory Downflow Vent Guard Kit required in downflow installations with bottom vent configuration. 7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kits for sizing and complete application details. 8. Secure vent connector to furnace elbow with(2)corrosion-resistant sheet metal screws,space approximately 180° apart. 9. Secure all other single wall vent connector joints with(3)corrosion-resistant screws spaced approximately 120° apart. Secure Type B vent connectors per vent connector manufacturer's recommendations. 6 i i I 0 0 Cl Q I 53 r SEE NOTES:1,2,4,5,7,8,9 SEE NOTES:1,2,4,5,7,8,9 HORIZONTAL RIGHT HORIZONTAL RIGHT A0206B A02070 I. O i I SEE NOTES:1,2,4,7,8,9 HORIZONTAL RIGHT A02069 ('CiW`1f I a � 0 0 O � SEE NOTES:1,2,4,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT A02064 A02065 1 t - 1 I I .• � y 11 I SEE NOTES: 1,2,4,5,7,8,9 SEE NOTES:1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT A02066 A02067 7 i ACCESSORIES D SCRIP710N PART NQ 024046 030046 024070 WW70 040070 DGM 040090 000080 036110 00110 006110 048136 06E136 000156 FILCABBB0016 x X X X X X X Media Filter Cabinet FILCABBB0020 X X x x X FILCABBB0024 X X FILBBCAH0016 X X X X X X X Cartridge Media Filter FILBBCAR0020 X X X X X FILBBCAR0024 A X EXPXXUNVO016 X X X X X X X EZ Flex Media Filter with End EXPXXUNV0020 X X X X X Caps EXPXXUNVO024 X X EXPXXFIL0016 X X x X X X X Replacement EZ Flex Filter Media FXPXXFILU020 x x x x X EXPXXFIL0024 X IX KUAFH0401 B14 X X X X External Bottom ReturnKGAFRO501 B17 X X X Filter Rack KGAFR0601 B21 X X X X x KGAFR0701B24 X External Side Return Filter Rack KGAFROB01SRE x X X X X X X X X X X X X X KGAWF1301UFRt X X X X X X X KGAWF1401UFR X X X X X Unframed Filter,3/4—in. KUAWF1501UFR X X (19 mm) KGAWF1306UFRt X x X X X X X KGAWF1406UFR X X X X X KGAWF1506UFR X X Flue Extension KGAFE0112UPH X X X X X X X X X X X X X X Iwinning Kit KGATWO601HSI X X x X X X X X X X X X X X Combustible Floor Base KGASB0201ALL x X X X X X X X X X X X X x Downtlow Vent Guard KOBVC30101 DFG X X X X X X X X X X X X X X Vent Extension Kit KGAVE0101 DNH X X X X X X X X X X X X X x Chimney Adapter KitKUAGA02014FC X X X X X X X X X X X KGACA02015FC X X X Natural—to—Propane KGANP4601ALL X X X X X X X X X X X X X X Conversion Kit. Propane—to—Natural KGAPN3901ALL X X X X X X X X X X X X X X Conversion Kit Label Kit KGALB0101 KIT X X X X x X X X X X X X X X Kit Gasket Door KGBAC0101 UGK X X X X X X X X I X X x X X X KGAHA0150N42 KGAHAO25ON43 (factory supplied) KGAHA035ON44 KGAHAO45ON45 KGAHA055ON46 Gas Orifice Kit(Oty 50) KGAHA1550N47 See Installation Instructions for model,altitude,and heat value usages, KGAHA165ON48 KGAHA0650P54 KGAHA075OP55 KOAHA065OP56 KGAHA5750125 KUAHA5750130 UV Lights Model UVL Heat/Energy Recovery Ventilator Models HRV or ERV Humidifier Model HUM Electronic Mechanical Air Cleanert Model EACA,EZXCAB,or FILCAB r$ * Factory authorized,field installed.Fuel conversion kits are CSA(formerly AGA/CGA)recognized. t Suitable for Side Return Filter Rack. t An external filter is required for all side return-air installations. X-Accessory S=Standard 8 I CONTROLS-THERMOSTAT & ZONING DESCRIPTION PART NO. NON-PROGRAMMABLE For use with 1-speed Air Conditioner—deg.F/C,Auto Changeover T6—NAC,T2—NAC For use with 1-speed Heat Pump—deg.F/C,Auto Changeover T6—NHP,T2—NHP* For use with 2-speed Air Conditioner—deg.F/C,Auto Changeover T6—NRH* For use with multi-use/stage configurations—deg.F/C,Auto Changeover/Temperature and Humidity Control T6—PRHt PROGRAMMABLE THERMOSTAT SELECTION For use with 1-speed Air Conditioner—deg.F/C,Auto Changeover,7-Day Programmable T6—PAC For use with 1-speed Heat Pump—deg.F/C,Auto Changeover,7-Day Programmable T6—PHP* For use with 2-speed Air Conditioner—deg.F/C,Auto Changeover,7-Day Programmable T6—PRH* For use with 1-speed Air Conditioner—deg.F/C,5-2 Day Programmable T6—PAC For use with multi-stage applications—deg.F/C,Auto Changeover,7-Day Programmable T2—PHP$ For multi-use/stage configurations—deg.F/C,Auto Changeover,7-Day Programmable/Temperature and T6—PRHt Humidity Control ZONING CONTROL SELECTION Zone Perfect 3-Zone kit ZONEBB3ZAC01, _ ZONEBB3ZHP01 Zone Perfect Plus 2-Zone kit/Temperature and Humidity Control ZONEBB2KIT01-B Zone Perfect Plus 4-Zone kit(remperature and Humidity Control ZONEBB4KIT01-B Zone Perfect Plus 8-Zone kit/Temperature and Humidity Control ZONEBBBKIT01-B * Model HP and 2S thermostat must be field converted to air conditioner operation. t Thermidistat Control can be configured for multiple use and staging.It must be configured for each specific application. t Dual Fuel thermostat is used with furnace and heat pump application. MODEL NUMBER NOMENCLATURE 3111 A A V 066 1';5 E Bryant Type Code Gas Furnace,4—Way Multipoise,80% Fixed—Capacity Model Code A=Standard J=Low NOx Series A B Variations Electrical Supply C A=110 to 125 Volts D E Brand Name Variations A—Common Unit Heating Size 000—None Coding Size 050—Heating Input 000 li None 005—Electrical Output 105—Oil Input 014—14,000 Btuh 037—Boiler Size 018—18,000 Btuh 012—Air 024—24,000 Btuh 060—Humidifiers 9 AIR DELIVERY—CFM (With Filter)* 370AAV/JAV RETURN-AIR EXTERNAL STATIC PRESSURE(In.W.C.) UNIT SIZE SUPPLY SPEED 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Bottom High 1085 1035 975 915 845 770 675 565 390 195 024045 or Med-High 920 875 830 770 710 640 555 440 250 — Side(s) Med-Low 820 775 730 680 620 555 470 360 190 — Bottom High 1440 1375 1305 1240 1160 1070 975 870 730 560 036045 or Med-High 1360 1300 1240 1175 1115 1040 950 850 725 575 Side(s) Med-Low 1250 1210 1160 1100 1040 965 885 790 670 520 Bottom High 1030 1010 980 945 900 845 775 680 490 335 024070 or Med-High 835 815 790 760 720 675 610 490 375 265 Side(s) Med-Low 725 700 675 645 600 555 475 390 300 — Bottom High 1425 1375 1320 1265 1200 1125 1035 940 830 655 036070 or Med-High 1320 1280 1240 1205 1140 1075 995 905 790 620 Side(s) Med-Low 1200 1175 1145 1105 1050 990 920 840 725 555 Bottom High 1805 1740 1670 1600 1530 1445 1360 1280 1180 1075 048070 or Med-High 1630 1585 1530 1470 1405 1330 1255 1170 1080 990 Side(s) Med-Low 1460 1420 1385 1325 1280 1220 1155 1080 995 910 Bottom High 1650 1600 1535 1465 1385 1285 1175 1055 895 645 042090 or Med-High 1515 1485 1440 1380 1300 1220 1115 990 830 600 Side(s) Med-Low 1385 1360 1320 1260 1195 1120 1025 915 710 565 Bottom High 2060 1985 1915 1820 1720 1610 1490 1340 1135 925 048090 or Med-High 1790 1765 1715 1645 1560 1470 1345 1195 1010 820 Side(s) Med-Low 1505 1505 1480 1440 1375 1300 1190 1045 890 740 Bottom High 2405 2310 2220 2130 2025 1920 1790 1660 1530 1350 Only Med-High 2225 2155 2080 1995 1895 1785 1675 1565 1420 1260 Med-Low 2020 1955 1880 1805 1730 1630 1535 1420 1275 1135 Both Sides High 2530 2450 2365 2270 2165 2065 1940 1805 1670 1505 060090 or Med-High 2285 2215 2150 2075 1985 1890 1780 1660 1525 1360 Side&Bottom Med-Low 1995 1945 1900 1840 1770 1685 1600 1460 1350 1180 High 2475 2395 2300 2200 2090 1985 1865 1730 1565 1425 1 Side Only Med-High 2260 2190 2110 2035 1940 1845 1735 1620 1475 1325 Med-Low 1950 1910 1855 1795 1730 1650 1555 1445 1310 1150 Bottom High 1625 1575 1515 1445 1355 1260 1165 990 785 — 036110 or Med-High 1510 1470 1415 1355 1285 1185 1070 890 725 — Side(s) Med-Low 1360 1335 1295 1250 1180 1100 985 810 — — Bottom High 2035 1965 1880 1790 1680 1495 1365 1215 1075 875 048110 or Med-High 1745 1710 1650 1560 1450 1340 1205 1090 955 750 Side(s) Med-Low 1530 1515 1470 1400 1310 1215 1095 990 830 670 Bottom High 2530 2470 2400 2320 2220 2115 2000 1865 1730 1590 Only Med-High 2230 2205 2165 2110 2035 1950 1855 1740 1615 1485 Med-Low 1920 1900 1880 1845 1795 1730 1650 1555 1460 1340 Both Sides High — — 2415 2350 2250 2145 2015 1875 1715 1560 066110 or1&Bottom Med-High 2235 2200 2155 2100 2040 1955 1850 1740 1595 1470 fe High 2540 2495 2430 2355 2265 2175 2065 1935 1785 1650 Side Only Med-High 2125 2120 2105 2060 2010 1940 1840 1730 1615 1485 Med-Low 1790 1795 1790 1765 1720 1650 1585 1500 1390 1280 Bottom High 2090 2010 1930 1835 1710 1590 1470 1335 1025 835 048135 or Med-High 1790 1755 1705 1640 1550 1465 1360 1210 945 785 Side(s) Med-Low 1545 1520 1500 1450 1380 1315 1215 1005 855 670 Bottom High 2485 2400 2310 2215 2110 2000 1880 1725 1535 1355 Only Med-High 2195 2150 2090 2000 1920 1825 1720 1565 1405 1255 Med-Low 1880 1850 1820 1780 1715 1635 1540 1415 1290 1160 Both Sides High — — 2385 2305 2195 2085 1960 1825 1670 1465 066135 or Med-High 2180 2145 2060 2010 1945 1865 1765 1660 1515 1325 ride&Bottom Med-Low 1880 1850 1820 1780 1715 1635 1540 1415 1290 1160 High — — 2245 2155 2055 1940 1825 1695 1555 1385 ide Only Med-High 2135 2085 2035 1975 1895 1795 1685 1565 1445 1265 Med-Low 1880 1850 1820 1760 1715 1635 1540 1415 1290 1160 Bottom High 2465 2430 2375 2305 2230 2110 2000 1865 1725 1545 Only Med-High 2115 2105 2075 2030 1980 1910 1830 1725 1590 1425 Med-Low 1800 1790 1770 1735 1695 1640 1570 1465 1345 1225 Bath Sides High — — 2375 2285 2200 2105 1995 1870 1730 1570 060155 or Med-High 2155 2135 2095 2040 1975 1895 1790 1685 1550 1400 Side&Bottom Med-Low 1800 1790 1770 1735 1695 1640 1570 1465 1345 1225 High — — 2260 2180 2085 1975 1865 1740 1605 1455 1Side Only Med-High 2140 2095 2040 1975 1890 1810 1705 1595 1480 1325 Med-Low 1800 1790 1770 1735 1695 1640 1570 1465 1345 1225 A filter is required for each return—air supply.Airflow performance includes 3/4 in.(19 mm)washable filter media such as contained in factory—authorized accessory filter rack.To determine airflow performance without this filter,assume an additional.1 available external static pressure. Indicates unstable operating conditions. 10 I �� ii I GUIDE SPECIFICATIONS Gas Furnace Inducer Motor 310AAV/JAV Inducer motor shall be soft mounted to reduce vibration General transmission. Draft Safeguard Switch SYSTEM DESCRIPTION Draft Safeguard Switch (blocked vent safeguard) shall Furnish a fixed capacity gas-fired be factory installed to reduce the possibility of vent gas furnace for use with natura gas or propane (factory infiltration due to a blocked or restricted vent pipe. authorized conversion kit required for propane); furnish Heat Exchangers cold air return plenum. Heat exchangers shall be a 4-Pass 20 gage aluminized QUALITY ASSURANCE steel of fold-and-crimp sectional design when applied Unit will be designed, tested and constructed to the operating under negative pressure. current ANSI Z 21.47/CSA 2.3 design standard for Controls gas-fired central furnaces. Control shall include a micro-processor non-volatile Unit will be 3rd party certified by CSA to the current memory based integrated electronic control board with at ANSI Z 21.47/CSA 2.3 design standard for gas-fired least 11 service troubleshooting codes displayed via central furnaces. enhanced flashing LED diagnostic light on the control, a Unit will carry the CSA Blue StarOO label. self-test feature that checks all major functions of the Unit efficiency testing will be performed per the current furnace within one minute, and a replaceable DOE test procedure as listed in the Federal Re ister. automotive-type circuit protection fuse. Multiple Unit will be certified for capacity and ezilency and operational settings available including, separate blower listed in the latest AHRI Consumer's Directory of speeds for heating, cooling, and continuous fan. Certified Efficiency Ratings. Continuous fan speed may be adjusted from the Unit shall carry the current Federal Trade Commission thermostat.Cooling airflow will be selectable between 350 Energy Guide efficiency label. or 400 CFM per ton of air conditioning. DELIVERY.STORAGE AND HANDLING OPERATING CHARACTERISTICS Unit shall be shipped as single package only and is Heating Capacity shall be Btuh input; stored and handled per unit manufacturer's Btuh output capacity. recommendations. Fuel Gas Efficiency shall be 80%AFUE. WARRANTY(for inclusion by specifying engineer) Air delivery shall be CFM minimum at U.S. and Canada only. Warranty certificate available 0.50 In.W.C.external static pressure. upon request. Dimensions shall be: depth in. (mm); Products width in. (mm); height in. (mm) EQUIPMENT (casing only). Height shall be in. (mm) with A/C coil and in. (mm) overall with Components shall include: slow-opening gas valve to plenum. reduce ignition noise, regulate gas flow, with electric ELECTRICAL REQUIREMENTS switch gas shut-off; flame proving sensor, hot surface Electrical supply shall be 115 volts, 60 Hz, igniter, pressure switch assembly, flame rollout switch, single-phase (nominal). Minimum wire size shall blower and inducer assembly, 40va transformer; be AWG; maximum fuse size or circuit breaker low-voltage(heating)(heating/cooling)thermostat. shall be Amps. Blower Wheel and Blower Motor SPECIAL FEATURES Galvanized blower wheel shall be centrifugal type, Refer to section of the product data sheet identifying statically and dynamically balanced.Blower motor of PSC accessories and descriptions for specific features and type shall be permanently lubricated with sealed bearings, available enhancements. of hp, and shall be multiple-speed direct drive. Blower motor shall be soft mounted to the blower scroll to reduce vibration transmission. Filters Furnace may have reusable-type filters. Filter shall be in(x) in.(mm). Casing Casing shall be of .030 in. (.76 mm) thickness minimum,pre-painted galvanized steel. ©2010 Bryant Heating&Cooling Systems s 7310 W.Morris St s Indianapolis,IN 46231 Printed in U S A. Edition Date:09/10 Catalog No. PDS310A.45.6 Manufacturer reserves the right to discontinue,or change at any time,specifications or designs without notice and without incurring obligations. Replaces:PDS 310A 45 5 12 t , 1 I Permit#: 1172 Permit Date: 10/12/16 Permit Type: RESIDENTIAL MECHANICAL Project Name: Carol Morales Applicant Name: Black Lion Heating and Air Conditioning Applicant Address: 11001 118th Place NE Applicant, City, State, Zip: Kirikland,WA 98033 Contact: Brenda Lopez Phone: 425-814-3944 Email: info@blacklionhvac.com Scope of Work: Replace Gas Furnace and Add A/C Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: Permit Expires: Form Permit Type: Status: EXPIRED Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning GLENEAGLE DIV.2 B FAULKINBURY 00809200002500 7722 KESTREL CRT PHASE 1 BLK 000 D-00 BRIAN/MORALES Residence Single Family -Detached LOT 25 CAROLINA Contractors Contractor Primary Contact Phone Address Contractor Type License License# BLACK LION 425-814-3944 11001 118TH PL CONSTRUCTION LABOR& BLACK LION HVAC HVAC NE CONTRACTOR INDUSTRIES BLACKLH873QQ Fees Fee Description Notes Amount Air Cond.Unit Btu/h<100>; $25.00 Btu/hp>500 Forced Air Heat fee per Btu $25.00 Mechanical Base Permit Fee $25.00 Total $75.00 Attached Letters Date Letter Description 10/13/2016 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 10/13/2016 Lynai Clark 61843960 cc $75.00 Outstanding Balance $0.00 Notes Date Note Created By: 12/12/2019 Permit not signed.Filed under address Raelynn Jones 10/13/2016 Bryant Furnace 310AAV Series E/Bryant AC 113A,SEER 13 Launa Black Uploaded Files Date File Name 10/12/2016 1889890-1172 Furnace Specs.pdf 10/12/2016 1889891-1172 Apnlication.pdf