HomeMy WebLinkAbout3506 168th St Ne_BLD6596_2026 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 3506 168TH ST NE Permit#:6596 PERMIT EXPIRES 180 DAYS AFTER Parcel#:31052800204200 DATE OF ISSUANCE. Scope of Work:Reconfigure existing ducting to supply air registers to new offices. Valuation:4400.00 OWNER APPLICANT CONTRACTOR Tom Rochon Right On Heating 6804 Bayview Dr.NW PO Box 758-2213 131st Ave NE Tulalip Lake Stevens,WA 98258 gWtr uG67 4253464825 425-335-4207 UC:602170524 1XP:1M1/2025 1414 MZ70 UC:RIGHTHM988CM EAR 02/14/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL MECHANICAL CODE YEAR: 2021 STORIES: I CONST.TYPE: VB DWELLING UNITS: OCC GROUP: M;Mercantile BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION.HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBCI 10/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 08/04/2025 Applicant a V V date/ Building Official Date i COMMERCIAL MECHANICAL APPLICATION • Community&Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping and must be accompanied by ELECTRONIC CONSTRUCTION DRAWINGS and CUT SHEETS and/or information outlined in the MECHANICAL SUBMITTAL REQUIREMENTS,if applicable. Type of Permit: ❑ New Installation ❑ Addition 0 Alteration ❑ Replaced ❑ Gas Piping Type I and Type II Hood Systems required submittal of the Commercial Mechanical Addenda Property Address: 3506 168th St NE Project Valuation: $4400.00 Lot#:2 Parcel ID No.: 31052800204200 Preferred Contact: 0 Owner O Contractor Convert existing branch back building to retail jewelry store.Adjust/relocate existing ducting for new retail office spaces. Project Description: Owner Name: WJ LLC (Wagner Jewelers -Jeff& Casey Wagner) Office No.: 360-653-8200 Email Address: jwagner871@aol.com & kcwagner32@hotmail.com Cell No.: Mailing Address: 9611 State Ave. city: Marysville state: WA Zip-98270 Contractor Name: Right on Heating Office No.: 425-335-4207 Email Address: contact@rightonheating.com Cell No.: Mailing Address: 2213 131 st Ave NE City: Lake Stevens State: WA zip: 98258 L&I Contractor License Number: RIGHTHM988CM Expiration Date: 02/14/2026 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured per IFGS,Section 415 • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of each appliance Gas Piping Specification and complete Schematic PAGE 3 O Not Applicable O CSST O Brass O Other Proposed Piping Material: O Black Steel O Galvanized Steel Proposed Piping Size: O 1/2" O 5/8 O 3/4" O 1" O 11/2 O 2" Inlet Pressure: Pressure Drop: Specific Gravity: I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above described property will be in accordance with the laws,rules and regulation of the State of Washington. 169'cfie.111 Thomas Rochon 07/01/25 Signature Print Name Date REV03.2022 Page 1 of 3 MECHANICAL PERMIT FEES (per unit Type of Fixture No.of Units Cost per Unit Subtotal Additional Plan Review fees x $ 75.00 = $ Air Conditioning Unit 15 100 Btu h x $ 15.00 = $ Air Conditioning Unit> 100 Btu h x $ 25.00 = $ Air Conditioning Unit> 500 Btu/hp x $ 50.00 = $ Air Handling Units x $ 15.00 = $ Base Mechanical Fee $ 25.00 $ 25.00 Boiler<100Btu h>3h x $ 15.00 = $ Boiler>1 million Btu/h<50hp x $ 25.00 = $ Boiler>1.5 million Btu/h<50hp x $ 50.00 = $ Boiler>100Btu h 3-15h x $ 15.00 = $ Boiler>500Btu h 15-30hp x $ 25.00 = $ Commercial Hoods-Type I x $ 25.00 = $ Commercial Hoods-Type II x $ 50.00 = $ Diffusers x $ 15.00 = $ Dryer Ducting 1 x $ 15.00 = $15.00 Ductwork(drawings required) 1 x $ 25.00 = $25.00 Evaporative Coolers x $ 15.00 = $ Exhaust Ventilation Fans 1 x $ 15.00 = $15.00 Fireplace/Insert/Stove x $ 15.00 = $ Forced Air Heat<_100 Btu h x $ 15.00 = $ Forced Air Heat>100 Btu h x $ 25.00 = $ Gas Clothes Dryer x $ 15.00 = $ Gas Fired Air Conditioning Unit 15 100 Btu h x $ 15.00 = $ Gas Fired Air Conditioning Unit> 100 Btu h x $ 25.00 = $ Gas Fired Air Conditioning Unit> 500 Btu/hp x $ 50.00 = $ Gas Pi in <_ 5 units x $ 15.00 = $ Gas Piping for each additional unit > 5 x $ 2.00 = $ Heat Exchangers x $ 15.00 = $ Heat Pump-Condensing Unit x $ 25.00 = $ Hot Water Heat Coils x $ 15.00 = $ Miscellaneous Appliance-regulated by x $ 15.00 _ $ mechanical code,not otherwise specified Package Units:5 100 Btu > 100 Btu x $ 25.00 $50.00 = $ Range/Cook top-Gas Fired x $ 15.00 = $ Refrigeration Unit<_100Btu h x $ 15.00 = $ Refrigeration Unit>100Btu h x $ 25.00 = $ Refrigeration Unit>500Btu h x $ 50.00 = $ Re-inspection fee all x $ 75.00 = $ Unit Heaters <_ 100 Btu h x $ 15.00 = $ Unit Heaters>100 Btu h x $ 25.00 = $ Variable Air Volume Boxes (part of Air x $ 10.00 = $ Conditioning System) Wall Heaters-Gas Fired x $ 25.00 = $ Water Heater- Gas Fired x $ 25.00 = $ Permit Fee $80.00 Table 4-8; Plan Review Fee $ Processing/Technology Fee $25.00 Total $ REV2.2024 Page 2 of 3 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated REV2.2024 Page 3 of 3 REVISIONS: Wagner Jewelers T . I . 3. 4. 5. 3506 168th St. NE Arlington, Washington 98223 PARCEL NO. 31052800204200 ABBREVIATIONS VICINITY MAP PROJECT PARTICIPANTS PROJECT DATA DRAWING INDEX OWNER: WJ,LLC-Contact Jeff Wagner&Casey Wagner JURISDICTION. City of Arington A0.1 Cover Sheet & AND (E) EXISTING L LENGTH SCD SEE CIVIL DRAWINGS 9611 State Ave.Ste E,Marysville,WA PROJECT ADDRESS 3506 168th St.NE A1.1 Existing Floor Plan/Demo Plan ANGLE EA EACH LAV LAVATORY SCH SCHEDULE Cell No.:360-202-7230 Arlington,WA.,98223 A2.1 Main Floor Plan @ AT ECB EROSION CONTROL BARRIER LF LINEAL FOOT SD SMOKE DETECTOR Email:jwagner871@aol.com 0 DIAMETER ELEC ELECTRICAL LPG LIQUID PROPANE GAS SECT SECTION kcwagner32@hotmail.com PARCEL NO. _ _ 31052800204200 DEGREE ENG ENGINEER(ING) LVL LAMINATED VENEER LUMBER SED SEE ELECTRICAL DRAWINGS CONTRACTOR: PCs Pioneer Construclion Services,Jim Fagerie CODE 2021 IBC WITH WASHINGTON # POUND OR NUMBER EQ EQUAL MAX MAXIMUM SF SQUARE FEET AMENDMENTS SQUARE FOOT EXT EXTERIOR MB MACHINE BOLT SH SINGLE HUNG 0""°"""°"""°'°""" ""°"'"` Contractor License No.PIONECS905NW AS ANCHOR BOLT FAU FORCED AIR UNIT MECH MECHANICAL SHT SHEET I ,M;"„",YP 0 Cell No.:425-508-2852 ABV ABOVE FD FLOOR DRAIN MFR MANUFACTURER SIM SIMILAR �O,aaaPo�",. Email:jim@pioneerconstructionservices.com ZONING. CC Commercial Corridor ACOUS ACOUSTIC FIE FIRE EXTINGUISHER MIN MINIMUM SL SLIDER DESIGNER: Tom Rochon LEGAL DESCRIPTION. .SEC 28 TWP 31 RGE 05 LOT 2 OF BSP REC AF ACT ACOUSTIC CEILING TILE FF FINISH FLOOR MISC MISCELLANEOUS SMD SEE MECHANICAL DRAWINGS a, „, o m 6804 Bayview Dr.NW 8804065010 AS AMD PER AF9502105002& AFF ABOVE FINISH FLOOR FG FULL GLASS MOD MODULAR SMS SHEET METAL SCREW _" " Tulalip,WA 98271 FURTHER AMD PER AF9507105005 TGW N 35FT ALUM ALUMINUM FHWS FLAT HEAD WOOD SCREW MTD MOUNTED SPD SEE PLUMBING DRAWINGS 0::4:, 1: '°^"9 o y m:p Cell No.:425-346-4825 s. '"' OF LOT 3 SD BSP BEING A PTN OF NW1/4 LESS ARCH ARCHITECTURAL FIN FINISH MTL METAL SPEC SPECIFICATIONS t Email:thomashrochon@gmail.com AWN AWNING FUR FLOOR MUL MULLED WINDOW SS STAINLESS STEEL :" ADDL IERd PER EC REC 5180558 PER & BD BOARD FOC FACE OF CONCRETE/COLUMN (N) NEW STD STANDARD a"'""' F"m°L1Pb1LP5➢ © PROJECT SITE: AM DRIER SWDREC2-BLA 1 REC PER CITY 03 BIF BIFOLD FOF FACE OF FRAMING/FINISH NG NATURAL GAS STK SELECT TIGHT KNOT .•mm.,"= °« 3506168th St.NE ARL BLA MN-99-0142-BLA REC AF799912035003 e h="wm.,m°per="� ° Arington,WA 98223 BLDG BLKG BUILDING BLOCKING FOIC FURNISHED BY OWNER,INSTALLED NIC NOT IN CONTRACT STL STEEL .,".,C O,a"^„.'" BLW BELOW BY CONTRACTOR NOM NOMINAL STRUC STRUCTURAL "g e m CONSTRUCTION TYPE TYPE VN BM BEAM FOS FACE OF STRUCTURE/STUD/STEEL NTS NOT TO SCALE STS SELF TAPPING SCREW ""W""`� -� SET BACKS. Front Yard ExI ng BTM BOTTOM FT FOOT OR FEET OC ON CENTER SV SHEET VINYL + m•°s,==_"�_ Side Yard Existing BUR BUILT-UP ROOFING FTG FOOTING OD OUTSIDE DIAMETER (T) TEMPERED •"�=o °"" L c CENTERLINE FX FIXED GLASS OPH OPPOSITE HAND T&G TONGUE&GROOVE °•°" sg`a Rear Yard Existing r CLG CEILING GA GAUGE OSB ORIENTED STRAND BOARD TBD TO BE DETERMINED MAXIMUM Existing CUR CLEAR GALV GALVANIZED PH PANIC HARDWARE TOC TOP OF CONCRETE BUILDING HEIGHT /A CMU CONCRETE MASONRY UNIT GLB GLULAM BEAM p PLATE Top TOP OF PLATE _ COL COLUMN GSM GALVANIZED SHEET METAL PLAM PLASTIC LAMINATE TOF TOP OF FLOOR ©";""oTc°°`�" L CCOMP CO POSITE GONC CONCRETE GYrPB GYPSUM GYPSUM WALLBOARD PR D PLYWOOD TTOS TO OF OW TOP OFWgLB/STEEL a BUILDING & LOT SIZE /�� Z 04 CONT CONTINUOUS HC HOLLOW CORE PSF POUNDS PER SQUARE FOOT TS TUBE STEEL EXISTING Y/ O CS CASEMENT HDR HEADER PT PRESSURE(PRESERVATIVE) TYR TYPICAL STRUCTURE to t' CPT CARPET HHS HEX HEAD SCREW TREATED UNO UNLESS NOTED OTHERWISE REMAIN .Existing Floor Area:3562 s.f. Q DBL DOUBLE HIM HOLLOW METAL REINF REINFORCING VERT VERTICAL DEMO DEMOLISH HORIZ HORIZONTAL RET RETAINING VIF VERIFY IN FIELD LOT SIZE AREA. . 55,846 s.f.or.78 acre(s) �\ j DET DETAIL HVAC HEATINGNENTILATION/ RHWS ROUND HEAD WOOD SCREW VPF VEGETATION PROTECTION FENCE W 0 DH DOUBLE HUNG AIR CONDITIONING RM ROOM VTO VENT TO OUTSIDE �•/ DIM DIMENSION ID INSIDE DIAMETER RO ROUGH OPENING W WIDTH r O DWG DRAWING INSUL INSULATION RWL RAINWATER LEADER W WITH t0 INT INTERIOR SC SOLID CORE WD WOOD L O WT WEIGHT M i SYMBOLS SITE PLAN a 168th St. NE DRAWING NUMBER � _ 174.70'REVISION REFERENCE / , REVISION NUMBER •;.fe`{Plarrigg'• •:{e)Plznieg •:• City g Arlington BUILDING SECTION X �•• •�-' ��'' '• "�'• '' •'���� �� Building Department OR WALL SECTION A4.1 SHEET NUMBER !• Exist. Property Owner g p REFERENCE MASONRY 1 Monument ;:(e)'Plz^)mg;• WJ LLC APPROVED n ;•::: 0 Exist.Light W Sign 7 Places) 4•:•'• I Site Address KevinOlander-07/30/2025 0 CONCRETE j Planting: 0 Places a ��.pl• M 3506 168th St.NE, DRAWING NUMBER STRUCTURAL Exisin Concrete •'.••• ♦••a REFERENCE 'I • '- '• 9 :' Arington,WA 98223 No changes authorized unless approved by EXTERIOR ELEVATION X GRIDS � T INSULATION(LOOSE OR BATT) -feJ Plantmg S dewalk •;:;1 REFERENCE A3.1 — (?I•pl?ning. Parcel No. the Building Official NOTE: INSULATION(RIGID) ��• 32'0" SHEET NUMBER ,_ •; 31052800204200 GRID LINES LOCATE FACE OF =•' $: 1 DRAWING NUning MBER FRAMING AND/OR ;;; 32'0" 170" 25'-0" -•14 b` FOUNDATION STEM WALLS EARTH 8sb° 8'fi" 25'-0" 18'-6" 1w 1/'8,, m I 42'-6" CZCO ercial Corridor INTERIOR ELEVATION UNO 4 A5.1 2 TRUE NORTH REFERENCE SHEET NUMBER SAND I PLASTER/MORTAR I-. ' ,{ o I. Legal Description 3 �ExPylon' q Existing •;.•� -O Sign 0 ,.1 N I SEC 28 TW P 31 RGE OS LOT 2 OF BSP REC AF NORTH ARROW Buildin DRAWING NUMBER NORTH { ,:•I 8804065010 AS AMD PER AF9502105002& ROCK FILL Footprint 3562 s.f. �' I FURTHER AMD PER AF9507105005 TGW N 35FT DETAIL REFERENCE m ® =o ' OF LOT 3 SD BSP BEING A PTN 32 0594 LESS AX.1 SHEET NUMBER ® METAL(LARGE SCALE) � 4 � � � t,� ADDL R/W PER SWD REC AF9303220594 8 AMD UP 7Rp 4 �16'a' O1I •'g, PER SWD REC AF9305180558 PER CITY OF ARL STAIR DIRECTION, #RISERS&TREADS 11T GYPSUM WALLBOARD r — — ,- BLA MN-99-0142-BLA REC AF799912035003 ROOM NAME 8 NUMBER ROOM FINISHED WOOD O 79-3• (e)Planing Lot Size ROOM NUMBER ® Y DOOR REFERENCE 101 O O .78 Acre or 33,977 s.f. 101X DOOR LETTER STRUCTURALWOOD E - •••.� Existing Building Area (CONTINUOUS MEMBER) U) LLI EQUIPMENT NUMBER 101 0 ';,•I 3562 s.f. '1' WINDOW REFERENCE <X}�WINDOW TYPE STRUCTURAL WOOD W CENTER LINES,FLOOR LINES _ � (NON-CONTINUOUS MEMBER) Epp Existing Landscape Area AT EXTERIOR ELEVATIONS, `-4 Dumpstar 9994 J. ''/^ PROJECTED LINES ® PLYWOOD Enclosure V) WALL TYPE �x WALL TYPE - _ Existing Parking Driveway Area PROP yp.ERTY LINES,BOUNDARY '• '• : T •'••' 18,824 s.f. '1' LINES ® TILE(CERAMIC) - '•:•:' ''• LJJ I•'KEY NOTE REFERENCE REFERENCE NUMBER Existing Parking Stalls Provided > '7t .fey'planing•'• _ v HIDDEN LINES ------------ 18 •,'d9)Pld!tti�q •1 1 ADA Parking Stall O •..I 29 Standard Parking Stalls All U CASEWORK REFERENCE 101 SCHEDULE NUMBER BREAK LINES A 30 Total Existing Parking Stalls �' Legend DATE:06.20.24 2 5 DE SIGNED:TR - Existing Asphalt(18,824 s.f.) DRAWN:TR True Existing North Existing Concrete Sidewalks(993 s.f.) SHEET: �� SITE PLAN 0:! 1_� 0 Existing Landscape(9994 s.f.) L \ II' / Date:06.20.25 a A 0 . 1 1 III/ Scale: 1"=20'-0" REVISIONS: 1. 2. 3. 4. 5. - - - - - - - - - - - - I I I I I I I I I I I I I I I I I I I I 6'-6" 4._1„ R.O. ❑ ❑ Drive-up Window I Storage Room ` Tellers \ jVault J 71 z, I I I I I I II I V I II I II I I II I I I I �/� I I I I II I II I II I II I I II I I I IL N L--- L----'I L--- ----J �---J ---J W N=J _� ZtbJanitor J— JL--- e L—J r— - r— � r— -- r— — r— _Y Y_J to W. M• Closet I �____� �____� �____� `_____� L L J Q Ilm� m� IIr----------------------------------� q II II M w c IIII II O _jLi, Fire L Extinguisher S Hall (FE) W M Q V/ 3'0"x TO" I—— Lobby Lounge/ Kitchen 3'o"xTo" 4 -- F---a' Fire ❑ F \ Extinguisher (F.EJ r �— J L fi ——J � Elect — Panel L——J II Office p Supplies tt I I � h�t �ti 06 L -- a O Demolition L LL 00 FLOOR PLAN 0 2' 4' 6' a, Wall Types Scale:1/4"=1'-0" U) North Existing Wall to Remain X 4-01 Existing Wall to be Removed � t Existing Window to be Removed City of Arlington -1 _ Existing Door to be Removed Building Department DATE:06.20.24 �\ APPROVED }� DESIGNED:TR Kevin Olander-07/30/2025 DRAWN:TR No changes authorized unless approved by SHEET the Building Official L a A1 . 1 REVISIONS: 1. 2. 3. 4. 5. I I I I I I I I I I I I I I I I g•_0" I N w (2)2' x4'0" Picture Window Watch Night Workbench Deposit -------------- Eating Countertop Security Fire ( Server Extinguisher (F.E.) Teller Wagner Jewelers wave New ry 4 Check-out Sign Kitchen o+` Jewelers _ _ J Water "' V Dispensor Stackabl Coals —— -- 22"z 22„— — 22"x 22„ — ®——— — — V a u It 3'0"x TO" • L S k dw I 43 Washer/ I I I I Take-In 1'-4" 2'-„" 1-6" Dryer ITIf Tl if TI IT IT 2-6- 6--6" 2'-10 3'0"x TO" New 3'_0" '_0" 12'-0" -r' t,a-6" 32 L W Cq OO q p• 2-Eq.Spaces tq 33 O00 W. M. z a) rn No Changes No Changes —————————————————————T-————————— U Q ..+ 0 2�6,�x T0" 4titi 34 s O�Q00 30'x7.0" Closet 19 18 1 241 0 ®�13 1 Sitting Fire 2'6"x 7'0" L C S Extinguisher Area u'> (F.E.) w 23 Island 14 M Q I I 4-8 O52 52 52 52 si nelers 21 16 3'°^x T°" g 1 12 w 2: II I I � 4•-4^ 4s 35 22•• 3O• O. ----K-iosk 7 Goldsmith © -------------J -D-1-5 ------------ Q26 3 '0"x7.0" Jewelers Stations , ----------------- - -19 7.1„ Fire Extinguisher Sink (F.E.) 9 6-10" I L Elect. Panel 2: ® 30 O5 © O7 ® q Elect. 58 2 0 Panel Polishing 3'0"x T0" UtiNew Jeffs lity Office Room Sink s7 59 Case 's hwt Y Office 37 —i 37 x T0" J I I a Proposed - O aD FLOOR PLAN 0 1' 2' 4' O WILL all Types Scale:1/4"=1'-0" North Existing Wall to Remain New Wall Construction City of Arlington 4_0 2x4 @ 16"o.c.w/5/6"GWe,Type X w/Sound Insulation Building Department (1) APPROVED (1) DATE:06.20.24 Kevin Olander-07/30/2025 4-0 DESIGNED:TR No changes authorized unless approved by DRAWN:TR the Building Official SHEET L a A2 . 1 Permit#: 6596 Permit Date: 07/02/25 Permit Type: COMMERCIAL MECHANICAL Project Name: Wagner Jewelers Tenant Improvement Applicant Name: Tom Rochon Applicant Address: 6804 Bayview Dr. NW Applicant, City, State, Zip: Tulalip Contact: Thomas Rochon Phone: 4253464825 Email: thomashrochon@gmail.com Scope of Work: Reconfigure existing ducting to supply air registers to new offices. Valuation: 4400.00 Square Feet: 3562 Number of Stories: 1 Construction Type: VB Occupancy Group: M; Mercantile ID Code: Permit Issued: 10/08/2025 Permit Expires: 04/07/2026 Form Permit Type: COMMERCIAL MECHANICAL Status: COMPLETE Assigned To: Hannah Hardwick Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 31052800204200 3506 168TH ST NE UNION BANK NA 611 Banking&Bank Related Functions Contractors Contractor Primary Contact Phone Address Contractor Type License License# Right On Heating Right on Heating 425-335-4207 PO Box 758-2213 CONSTRUCTION UBI 602 170 524 131 st Ave NE CONTRACTOR Right On Heating Right on Heating 425-335-4207 PO Box 758-2213 CONSTRUCTION L&I RIGHTHM988CM 131 st Ave NE CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status C 14. 03/12/2026 MECHANICAL O1/05/2026 BUILDING Approved FINAL Plan Reviews Date Review Type Description Assigned To Review Status 07/02/2025 COMMERCIAL BUILDING Approved MECHANICAL Fees Fee Description Notes Amount Enter 1 if permit is for commercial Web Only-Mechanical Commercial Plan mechanical $99.46 Review (Table 4-1) Credit Card Service $2.98 Processing/Technology $25.00 Dryer Ducting Enter#of units $15.00 Ductwork/Dryer Duct $25.00 ExhaustNentsNent Fans $15.00 Mechanical Base Permit Fee $25.00 Credit Card Service $3.15 Total $210.59 Attached Letters Date Letter Description 08/04/2025 Building Permit 07/02/2025 Web Form-Building Application Payments Date Paid By Description Payment Type Accepted By Amount 07/02/2025 Thomas Rochon 235943934 Hannah Hardwick $2.98 07/02/2025 XBP Conf: $99.46 235943934 08/04/2025 Thomas Rochon 239072290 $3.15 08/04/2025 XBP Con£ $105.00 239072290 Outstanding Balance $0.00 Notes Date Note Created By: 03/02/2026 sent expiration notice Hannah Hardwick Uploaded Files Date File Name 10/08/2025 28692867-2025 BLD6596 Issued Permit.pdf 07/02/2025 05dcb107b7dc68baa63fbOdc0e09bdf7 wagner jeweler permit set combined 062025.pdf 07/02/2025 c2df35a7e704209d22c744370d80226f wagner jewelers t.i. commercial mechanical .pdf