Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20301 45TH DR NE_BLD1120_2026
RESIDENTIAL MECHANICAL PERMIT APPLICATION t�N Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:20301 45th Dr NE Project Description:Replacing gas furnace Owner: Julia Rersnyak Address. 20301 45th Dr NE City. Arlington StateyVA Zip Code: 98223 Phone. 425-780-3075 Email:juliarezrez@gmail.com Applicant: Ethan Onat Address. 3909 196th St SW City. Lynnwood State WA Zip Code: 98036 Phone. 206-378-6927 Email. eonat@washingtonenergy.com CONTRACTOR INFORMATION Contractor Name:Washington Energy Services Address: 3909 196th St SW City. Lynnwood State WA Zip Code: 98036 License Number-WASHIES851NS Expiration: 09/07/17 Phone: 206-378-6927 E m a i 1:eonat@was hi ngtonenergy.com STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 Y. RESIDENTIAL MECHANICAL PERMIT APPLICATION SING Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #312JAV06070 AFUE80% ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: [El Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances c��� Ik,�,d==,�366,<�sz,a,�dea,,,ee„e� Applicant Signature: Date: 08/12/2016 Applicant Printed Name: Ethan Kerem Onat I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:203411 45th Drive NF, Permit#:1120 Parcel N:00898600006400 Valuation:0.00 OWNER APPLICANT_ CONTRACTOR , Name KEI.LY MICHAEL A/NIAKOUS JULIA H Name:Ethan Onat Name:WASI11NGTON ENERGY SERVICES Address:20301 45TH DR NE Address:3909 196th St SW Address:3909 196th Street S W City,State Zip:ARLINGTON,WA 98223-4721 City,State Zip:Lynnwood,WA 98036 City,Slate'Zip:Lynnwood,WA 98036 Phone: Phone:206-378-6927 Phone:800-398-4663 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:WASHINGTON ENERGY SERVICES Name: Address:3909 I%lh Street SW Address: City,Stnte,Zip:Lynnwood,WA 98036 City,State,Zip: Phonc:$00.398-4663 Phone: LICa:WASHIES85INS EXP: 9/712017 I.ICN: EXP: JOB DESCRIPTION T PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: 2 CONST.TYPE: DWELLING UNITS: ] OCCCIROIIP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE.TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18,27. TI IIS APPL1CAT10N IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HISA IER DF.PU'fY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL.INSPECTION HAS BEEN MADE:AND APPROVAL OR A CERI-IFICA'I''.OF OCCUPANCY HAS BEEN GRANTED, IBCI l0/IRCI]0. SALES TAX N 'ICE:Sales tax relating to construction and construction materials in the City of Arlington re rt'd on your sales tax return form and coded City of r' gton tl3101, .� AV Alal ? 46 Z Si o are Print Name Date s Dale CONDITIONS Adhere to it tallation of model 9 312JAV06070. Duct testing is required per the 2015 Washington Energy Code R402.1.2 THIS PERMIT AUTIIORIZS ONLY THE WORK NOTED,THIS PERMIT COVERS WORK TO REDONE ON PRIVA t'E PROPERTY ONLY, ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,PXC,)WILL REQUIRE:SEPARATE PERMISSION, PERMIT FEES Date Description Fee Amount 8/12/2016 Furnace $25.00 8/12/2016 Mechanical Permit Base Fee $25.00 Total Due: $50.00 Total Payment: $50.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 ` PHONE; (360)403-3551 BUILDING PERMIT Address:20301 45th Drive NE Permit#:1120 Parcel#:00898600006400 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:KELLY MICHAEL A/MAKOUS JULIA H Name:Ethan Onat Name:WASHINGTON ENERGY SERVICES Address:20301 45TH DR NE Address:3909 196th St SW Address:3909 196th Street SW City,State Zip:ARLINGTON,WA 98223-4721 City,State Zip:Lynnwood,WA 98036 City,State Zip:Lynnwood,WA 98036 Phone: Phone:206-378-6927 Phone:800-398-4663 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:WASHINGTON ENERGY SERVICES Name: Address:3909 196th Street SW Address: City,State,Zip:Lynnwood,WA 98036 City,State,Zip: Phone:800-398-4663 Phone: LIC#:WASHIES85INS EXP: 9/7/2017 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: 2 CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington re 7t don your sales tax return form and coded City of Arlington#3101. Signature Print Name Date s Date CONDITIONS Adhere to installation of model # 312JAV06070. Duct testing is required per the 2015 Washington Energy Code R402.1.2 THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION, PERMIT FEES Date Description Fee Amount 8/12/2016 Furnace $25.00 8/12/2016 Mechanical Permit Base Fee $25.00 Total Due: $50.00 Total Payment: $50.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon I 4-Way Multipoise 312AAV/312JAV ® Induced Combustion Sizes 045 thru 155 Heating&Cooling Systems Gas Furnace Series A The 312AAV/JAV Two-stage 4-way Mulitpoise Gas Furnace offers outstanding comfort in an 80% AFUE furnace. You get the benifits of Perfect HeatTM: reduced drafts, reduced sound levels, longer cycles, less temperature swings between cycles, a less temperature differences between rooms, and �. improved indoor air quality. Plus, it features a la' law�ml lxw�ml lw� dehumidify mode and the ability to change continuous fan speeds from the thermostat. The 1_ftww�ml law 312AAV/JAV furnaces are approved for use with natural or propane gas, and the 312JAV is approved for use in Low NOx Air Management Districts. PWs80 STANDARD FEATURES " • Perfect HeatT"" operation Two-stage heating Very low operating sound through low-stage operation and noise elimination combustion system • Four-position furnace: upflow, horizontal right, horizontal left, downflow Thirteen different vent options Shorter in height - only 331/3" tall Media Filter Cabinet included • Microprocessor based "smart" control center Adapts heating stages to meet demand Continuous Fan speed adjustable from thermostat Adjustable heating air temperature rise LED diagnostics, non-volatile fault code memory, and self test feature 0 • Patented blocked vent safeguard to ensure --= proper furnace venting A02181 All models are Chimney Friendly when used with accessory vent kit DESIGN Ga<<e�G°r D%`,�� • Insulated blower compartment Heat pump compatible SP $P UL , : Hot surface Ignition (HSI) CERTIFIED CERTIFIED Aso 9001 #• consumer Rble for esidential through lthe Comfort PZ REGISTERED onsume QUALITY SYSTEM Credit Program MEETS DOE RESIDENTIAL CONSERVATION LIMITED WARRANTY CEFFICIENCY SERVICES PROGRAM STANDARDS, 20-year Warranty On "Super ST""" heat exchanger RATING CERTIFIED • 5-year arts warrant on all other components ama Before purchasing this appliance,read important y p y p energy cost and efficiency information available from your retailer. Form No. PDS 312A.45.2 8-7/8"' 26-1/8" (VENT CONNECTION) 5-1/4" 1-9/16" 2-9/16" 2-9/16" AIRFLOW JUNCTION BOX D 13/16" 19" 13/16" LOCATION F 4-13/16" OUTLET i --- i 7/8"DIA o000 ACCESSORY o000 8-7/16" 11/16" 0000 /2"DIA. 1/2"DIA THERMOSTAT o00o RIGHT HAND WIRE ENTRY o00o GAS ENTRY 0000 3-15/16" 0000 1/2"DIA.THERMOSTAT WIRE ENTRY LEFT HAND GAS 1-7/16" ENTRY ALTERNATE 33-5/16" P----------------- 24-7/8" JUNCTION BOX - --------- ' LOCATION(TYP) VENT OUTLET 5 PLACES(TYP) 14-7/8" 7/8"DIA.ACCESSORY 3-3/4" ( 7/8"DIA.ACCESSORY 11/16" L 21-5/8" _� 1-11/16" C BOTTOM INLET 22-1/16" 1" 24" SIDE INLET (CASING) NOTES: 1. Two additional 7/8-in.dia knockouts are located in the top plate. 2. Minimum return-air openings at furnace,based on metal duct. If flex duct is used, see flex duct manufacturer's recommendations for equivalent diameters. 3. Minimum return-air opening at furnace: a. For 800 CFM-16-in.round or 141/2 x 12-in.rectangle. b. For 1200 CFM-20-in.round or 14'/2 x 191/2-in.rectangle. c. For 1600 CFM-22-in.round or 141/2 x 22'/,6-in.rectangle. d. For airflow requirements above 1800 CFM,see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets,a combination of 1 side and the bottom,or the bottom only will ensure adequate return air openings for airnow requirements above 1800 CFM. A D E F VENT 31 IT/SIZE V (CABINET (SUPPLY (BOTTOM RETURN (BOTTOM CONS ZE ION SHIPPING WEIGHT WIDTH) WIDTH) WIDTH) VENT OUTLET) (see notes 1 &2) 024045 14-3/16 12-9/16 12-11/16 9-5/16 4 116 036045 14-3/16 12-9/16 12-11/16 9-5/16 4 119 024070 14-3/16 12-9/16 12-11/16 9-5/16 4 120 036070 14-3/16 12-9/16 12-11/16 9-5/16 4 124 048070 17-1/2 15-7/8 16-1/8 11-9/16 4 138 042090 17-1/2 15-7/8 16-1/8 11-9/16 4 136 048090 21 19-3/8 19-1/2 13-5/16 4 151 060090 21 19-3/8 19-1/2 13-5/16 4 156 036110 17-1/2 15-7/8 16-1/8 11-9/16 4 144 048110 21 19-3/8 19-1/2 13-5/16 4 158 066110 21 19-3/8 19-1/2 13-5/16 4 163 048135 21 19-3/8 19-1/2 13-5/16 4(note 1) 163 066135 24-1/2 22-7/8 23 15-1/16 4(note 1) 174 060155 24-1/2 22-7/8 23 15-1/16 4 note 1 181 1) 135 and 155 size furnaces require five-inch vents. Use a 4-5 inch vent adapter between furnace and vent stack. 2) See Installation Instructions for complete installation requirements. 25" 23' -231' yl Opening with Flanges Bent 1�1-22°k" ~ 22 ln�~I Opening I I I I A I I Furnace Side 4-L 11 I Dud Side I I I 23 le' Centerline Screw Slots I�5 „ �11 Media/ A02210 Filter Cabinet A B 16" 17" 16" 20" 21" 20" 24" 25, 24" -2- INSTALLATION MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION DISTANCE MINIMALE EN POLICES AUX CONSTRUCTIONS COMBUSTIBLES This forced air furnace is equipped for use with This furnace is approved for UPFLOW,DOWNFLOW, and natural gas at altitudes 0-10,000 ft(0-3,050m). HORIZONTAL installations. An accessory kit, supplied by the Cette fournaise est approuv6e pour I"installation HORIZONTALE manuracturer,shall be used to convert to propane at la droulation d"air VERS LE HALT at VERS LE RAS. gas use or may be required for some natural gas T. applications. Clearance arrows Les f 6ches de degagement do not change with a ne changent pas aver This furnace is for indoor installation in a furnace orientation. a I"orientation de la fournaise. building constructed on site. This furnace may be installed on combustible Z� flooring in alcove or closet at minimum clearance as indicated by the diagram from combustible 0" $ 0" material. A R B A K u� This furnace may be used with a Type B-1 Vent R I E of obt and may be vented in corrrron with other gas- R E o�"aP 5� fired appliances. 0 Cette fournaise a air pulse est equipee eP PNZ s e pour utilisation aver gaz naturel et altitudes OE F ENTRET!aE comprises entre 0-3,050m(0-10,000 pi). s R Utiliser une trousse de conversion,fournle par �bj AVANT EN 30' le fabricant,pour passer au gaz propane ou pour *01, T 31M certaines installations au gaz naturel. 0 Cette fournaise est prevue pour titre N installee clans un batiment construit sur place. Clearance in inches Cette fournaise peut titre installee sur d D6gagement(po). un plancher combustible dans une alcove ou dans un garde-robe en respectant le minimum d'espace libre des mat6daux combustibles,tel Vent Clearance to combustibles: qu'indique sur le diagramme. For Single Wall vents 6 inches(6 po). Cette fournaise peut titre utilisee avec un For Type B-1 vent type 1 inch(1 po). conduit d"evacuation de Type B-1 ou connectee Degagement de I"event aver combustibles: Pour conduit d"evacuation a paroi simple 6 po(6 inches). au conduit oommun d"autres appareils a gaz. Pour conduit d"evacuation de Type B-1 1 1 inch). MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION DOWNFLOW POSITIONS: t Installation on non-combustible floors only. For Installation on combustible flooring only when installed on special base,Part No.KGASB0201ALL, Coil Assembly,Part No. CD5 or CK5,or Cal Casing,Part No.KCAKC. 0 18 inches front clearance required for alcove. * Indicates supply or return sides when furnace is in the horizontal position.Line contact only permissible between lines formed by intersections of the Top and two Sides of the furnace jacket,and building joists, studs or framing. DEGAGEMENT MINIMUM EN POLICES AVEC ELEMENTS DE CONSTRUCTION COMBUSTIBLES POUR LA POSITION COURANT DESCENDANT: t Pour "installation sur plancher noncombustible seulement. Pour I"installation sur un plancher combustible seulement quand on utilise la base sp6dale,piece no KGASB0201ALL, 1"ensemble serpentin,piece no CD5 ou CK5,ou le carter de serpentin,piece no KCAKC. 0 Dans une alcove,on dolt maintenir un degagement a I"avant de 18 po(450 mm). * La position indiqu6e conceme Ie cote d'entree ou de retou quand la foumaise est dans la position horizontale. Le contact nest perms qu"entre les lignes fomh6es par les intersections du dessus et des deux cotes de la chemise cle la fournaise et les solives,montant sous cadre de charpente. 327590-101 REV. B CONTROLS-THERMOSTATS AND ZONING Auto Changeover,°F/°C, 1-Stage Heat/1-Stage Cool-TSTATBBNAC01-B Auto Changeover,°F/°C,2-Stage Heat/1-Stage Cool-TSTATBBNHP01-13 THERMOSTAT-NON-PROGRAMMABLE Auto Changeover,°F/°C,2-Stage Heat/2-Stage Cool-TSTATBBN2S01-B in AC Mode,3-Stage Heat/2-Stage Cool in HP Mode Air Conditioner,1-Stage Heat/1-Stage Cool,Manual Changeover,°F/°C-TSTATBBBAC01 Heat Pump,2-Stage Heat/1-Stage Cool,Manual Changeover,°F/°C-TSTATBBBHP01 Auto Changeover,7-Day Programmable,°F/°C,1-Stage Heat/1-Stage Cool-TSTATBBPAC01-B Auto Changeover,7-Day Programmable,°F/°C,2-Stage Heat/1-Stage Cool-TSTATBBPHP01-B Auto Changeover,7-Day Programmable,°F/°C,2-Stage Heat/2-Stage Cool-TSTATBBP2SO 1-B THERMOSTAT-PROGRAMMABLE in AC Mode,3-Stage Heat/2-Stage Cool in HP Mode Dual Fuel Thermostat,includes Outdoor Air Temperature Sensor-TSTATBBPDF01-B Thermidistat Control-Non-Programmable/Programmable Thermostat-TSTATBBP RHO 1-B with Humidity Control(For use in Dual Fuel,AC,HP,and 2S applications.Includes Outdoor Air Temperature Sensor.) ZONING-2-ZONE ZONEBB2KIT01-B,ZONEKIT2ZBDP ZONING-4-ZONE ZONEBB4KITO1-B ZONING-8-ZONE ZONEBB8KIT01-B *Do not use in zoning heat pump applications. -3- SPECIFICATIONS UNIT SIZE 024045 036045 024070 036070 048070 042090 048090 PERFORMANCERATINGS AND 312JAV U flow;all 312AAV -High 44,000 44,000 66,000 66,000 66,000 88,000 88,000 Input Btuh -Low 29,000 29,000 43,500 43,500 43,500 58,000 58,000 Nonweatherized ICS 312JAVDownflow/Horizontal-High 42,000 42,000 63,000 63,000 63,000 84,000 84,000 -Low 29,000 29,000 43,500 43,500 43,500 58,000 58,000 312JAV U flow;all 312AAV -High 35,000 36,000 54,000 54,000 53,000 71,000 71,000 Output Capacity(Btuh)t -Low 23,000 23,000 36,000 36,000 35,000 47,000 47,000 Nonweatherized ICS 312JAVDownflow/Horizontal -High 34,000 34,000 51,000 51,000 51,000 68,000 68,000 -Low 23,000 23,000 36,000 36,000 35,000 47,000 47,000 AFUE t 80.0 80.0 80.0 80.0 80.0 80.0 80.0 Certified Temperature Rise Range°F High 30-60 20-50 40-70 30-60 25-55 40-70 30-60 Low 20-50 15-45 30-60 30-60 15-45 1 25-55 25-55 Certified External Static Pressure Heat/Cool 1 0.10/0.50 0.10/0.50 0.12/0.50 0.12/0.50 0.12/0.50 0.15/0.50 0.15/0.50 Airflow CFM t Heating High/Low 820/725 1030/860 790/685 885/695 1570/1045 1375/1195 1265/1030 Cooling 1 895 1175 1 955 1240 1605 1385 1755 ELECTRICAL Unit Volts-Hertz-Phase 115-60-1 Operating Voltage Range Min-Max 104-127 Maximum Unit Amps 5.4 7.1 5.1 7.3 10.1 8.1 9.9 Maximum Wire Length(Measured 1 Way in Ft) 49 38 51 37 27 34 28 Minimum Wire Size 14 Maximum Fuse or Ckt Bkr Size(Amps)*" 15 Transformer(24v) 40va External Control Heating 12va Power Available Cooling 35va Air Conditioning Blower Relay Standard CONTROLS Limit Control SPST Heating Blower Control Solid-State Time Operation Burners(Monoport) 2 2 3 3 3 4 4 Gas Connection Size 1/2-in.NPT GAS CONTROLS White Rodgers Gas Valve(Redundant) Min Inlet Pressure(In.wc) 4.5(Natural Gas) Max Inlet Pressure(In.wc) 13.6(Natural Gas) Ignition Device Hot Surface BLOWER Direct-Drive Motor HP(PSC) 1/5 1/3 1/5 1/3 1/2 1/3 1/2 Motor Full Load Amps 2.8 5.1 2.8 5.1 7.4 5.1 7.4 RPM(Nominal)-Speeds 1075-4 1075-5 1075-4 1075-5 1075-5 1075-4 1075-5 Blower Wheel Diameter x Width In. 10 x 6 10 x 6 10 x 6 10 x 6 11 x 8 10 x 8 10 x 10 *Gas input ratings are certified for elevations to 2000 ft.For elevations above 2000 ft,reduce ratings 4 percent for each 1000 ft above sea level.Refer to National Fuel Gas Code Table F4 or furnace Installation Instructions.In Canada,derate the unit 10 percent for elevations 2000 ft to 4500 ft above sea level. ** Time-delay type is recommended. tCapacity in accordance with U.S.Government DOE test procedures. t Airflow shown is for bottom only return-air supply for the as-shipped speed tap.For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required for each return-air supply. An airflow reduction of up to 7%may occur when using the factory-specified 4-5/16-inch wide,high efficiency media filter. ICS-Isolated Combustion System N/A-Not Applicable -4- SPECIFICATIONS UNIT SIZE 060090 036110 048110 066110 048135 066135 060155 RATINGS AND PERFORMANCE 312JAV Upflow;all 312AAV -High 88,000 110,000 110,000 110,000 132,000 132,000 154,000 Input Btuh* -Low 58,000 72,500 72,500 72,500 87,000 87,000 101,500 Nonweatherized ICS 312JAVDownflow/Horizontal-High 84,000 105,000 105,000 105,000 126,000 126,000 147,000 -Low 58,000 72,500 72,500 72,500 87,000 87,000 101,500 312JAV U flow•all 312AAV -High 71,000 89,000 89,000 89,000 107,000 107,000 124,000 Output Capacity(Btuh)t -Low 47,000 59,000 59,000 59,000 70,000 70,000 82,000 Nonweatherized ICS 312 AVD wnflow Horiz nt I -High 68,000 85,000 85,000 85,000 102,000 102,000 119,000 -Low 47,000 59,000 59,000 59,000 70,000 70,000 82,000 AFUE t 80.0 80.0 80.0 80.0 80.0 80.0 80.0 Certified Temperature Rise Range°F High 25-55 50-80 40-70 30-60 50-80 40-70 45-75 Low 15-45 30-60 25-55 20-50 30-60 25-55 30-60 Certified External Static Pressure Heat/Cool 1 0.15/0.50 1 0.20/0.50 1 0.20/0.50 0.20/0.80 0.20/0.50 0.20/0.50 0.20/0.50 Airflow CFM$ Heating High/Low 1580/1325 1 1335/1180 1 1290/1045 1555/1295 1525/1320 1865/1640 1790/1565 Cooling 2005 1355 1695 2200 1710 2110 2230 ELECTRICAL Unit Volts-Hertz-Phase 115-60-1 Operating Voltage Range Min-Max 104-127 Maximum Unit Amps 12.8 8.1 10.1 13.6 10.0 14.4 15.0 Maximum Wire Length(Measured 1 Way in Ft) 34 34 27 32 28 31 29 Minimum Wire Size 12 14 12 14 12 Maximum Fuse or Ckt Bkr Size(Amps)"' 20 15 20 15 20 Transformer(24v) 40va External Control Heating 12va Power Available Cooling 35va Air Conditioning Blower Relay Standard CONTROLS Limit Control SPST Heating Blower Control Solid-State Time Operation Burners(Monoport) 4 5 5 5 6 6 7 Gas Connection Size 1/2-in.NPT GAS CONTROLS White Rodgers Gas Valve(Redundant) Min Inlet Pressure(In.wc) 4.5 Natural Gas Max Inlet Pressure(In.wc) 13.6 Natural Gas Ignition Device Hot Surface BLOWER Direct-Drive Motor HP(PSC) 3/4 1/3 1/2 3/4 1/2 3/4 3/4 Motor Full Load Amps 11.0 5.2 7.4 11.0 7.9 11.1 11.1 RPM(Nominal)-Speeds 1075-5 1075-4 1075-5 1075-5 1075-4 1075-4 1075-4 Blower Wheel Diameter x Width(In.) 11 x 11 10 x 8 10 x 10 11 x 11 10 x 10 11 x 11 11 x 11 *Gas input ratings are certified for elevations to 2000 ft.For elevations above 2000 ft,reduce ratings 4 percent for each 1000 ft above sea level.Refer to National Fuel Gas Code Table F4 or furnace Installation Instructions.In Canada,derate the unit 10 percent for elevations 2000 ft to 4500 ft above sea level. ** Time-delay type is recommended. tCapacity in accordance with U.S.Government DOE test procedures. $Airflow shown is for bottom only return-air supply for the as-shipped speed tap.For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required for each return-air supply. An airflow reduction of up to 7%may occur when using the factory-specified 4-5/16-inch wide,high efficiency media filter. ICS-Isolated Combustion System N/A-Not Applicable -5- lit Ll LLL LLLLLI e O O O SEE NOTES:1,2,4,7,8,9 SEE NOTES:1,2,3,4,7,8,9 SEE NOTES:1,2,4,5,7,8,9 UPFLOW UPFLOW DOWNFLOW A02058 A02059 A02061 lluu-i i � � r�Ili ii i Ili ii Gi 'i j I I I I Ie e e e I e e o I I I I I I I I I I I _ SEE NOTES:1,2,3,4,5,7,8,9 SEE NOTES:1,2,3,4,5,7,8,9 SEE NOTES:1,2,4,5,6,7,8,9 DOWNFLOW DOWNFLOW DOWNFLOW A02060 A02063 A02062 Venting Notes 1.For cornnon vent,vent connector sizing and vent material•United States,latest edition ofthe National Fuel Gas Code(NFGC),ANSI Z223.1/NFPA54. In Canada,latest edition ofthe National Standards of Canada, Natural Gas and Propane Installation Code(NSCNGPIC),CSAB149.1-00. 2.Immediately increase to 5-inch vent connector outside fixmace casing when 5-inch vent connector required, refer to Note 1. 3. Side outlet vent for upflow and downflow installations must use Type B vent imrnediately affer exiting the furnace,except when KGAVGO101DFG is used in downflowposition. 4.Type B vent where required,refer to Note 1. 5.4"single wall vent must be used inside fixmace casing and the KGAVGO10lDFG Downflow Vent Guard Kit. 6.Accessory Downflow Vent(yard Kit,KGAVGOI O1DFG required in downflow installations with bottom vent configuration. 7.Chimney Adapter Kit required for exterior masonry chinmey applications. Refer to Chirmey Adapter Kit, KGACA02014FC and KGACA02015FC for sizing and complete application details. 8. Secure vent connector to furnace elbowwith(2)corrosion-resistant sheet metal screws,space approximately 1800 apart. 9. Secure all other single wall vent connector joints with(3)corrosion-resistant screws spaced approximately 1200 apart. Secure Type B vent connectors per vent connector manufacturer's recommendations. -6- 111W W 10 O 1 O a --- o 0 II III I 00. °o. SEE NOTES:1,2,4,5,7,8,9 HORIZONTAL RIGHT SEE NOTES:1,2,4,5,7,8,9 HORIZONTAL RIGHT A02068 A02070 o° loll li Ali I j III�I I i o. SEE NOTES:1,2,4,7,8,9 HORIZONTAL RIGHT A02069 W W 1\\ i III IIII II I � o .o ,a SEE NOTES:1,2,4,7,8,9 HORIZONTAL LEFT SEE NOTES:1,2,4,5, A02064 HORIZONTAL LEFT A02065 11lWWll ir 0 0 0 SEE NOTES:1,2,4,5,7,8,9 SEE NOTES:1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT A02067 A02066 -7- FACTORY-AUTHORIZED DESCRIPTION PART NO. 024045 036045 024070 036070 048070 042090 048090 060090 036110 048110 066110 048135 066135 060155 EZ Flex Media Filter with end EXPXXUNV0016 x x x x x x x caps-16 i n.(9 pack) EZ Flex Media Filter with end EXPXXUNV0020 x x x x x caps-20 i n.(9 pack) EZ Flex Media Filter with end EXPXXUNV0024 x x caps-24 i n.(6 pack) Replacement EZ Flex Filter-16 EXPXXFIL0016 x x x x x x x in.(10 pack) Replacement EZ Flex Filter-20 EXPXXFIL0020 x x x x x in.(10 pack) Replacement EZ Flex Filter-24 EXPXXFIL0024 x x in.(10 pack) Unframed filter,one inch-16x25 KGAW F1301 UFR x x x x x x s s x s s s s s KGAWF1306UFR(6-pack) Unframed filter,one inch- KGAWF1401UFR x x x x x 20x25 KGAWF1406UFR(6 pack) Unframed filter,one inch- KGAWF1501UFR x x 24x25 KGAWF1506UFR(6 pack) Twinning Kit KGATW0601HSI x x x x x x x x x x x x x x Combustible Floor Base(not required when evaporator coil KGASB0201ALL x x x x x x x x x x x x x x case is used) Downflow Vent Guard(not required when vent is routed KGAVG0101 DFG x x x x x x x x x x x x x x through cabinet) Vent Extension Kit(may be used when vent is routed through KGAVE0101 DNH x x x x x x x x x x x x x x cabinet in downflow) Chimney Adapter Kit-4 i nch KGACA02014FC x x x x x x x x x x x vent Chimney Adapter Kit-5 i nch KGACA02015FC x x x vent Natural-to-Propane Gas * KGANP2901ALL x x x x x x x x x x x x x x Conversion Kit(Single Kit) Propane-to-Natural Gas KGAPN2301ALL x x x x x x x x x x x x x x Conversion Kit(Single Kit) Gas Orifice Kit(Qty 50)Size 42 KGAHA0150N42 Gas Orifice Kit(Qty 50)Size 43 KGAHA0250N43 Gas Orifice Kit(Qty 50)Size 44 KGAHA0350N44 Gas Orifice Kit(Qty 50)Size 45 KGAHA0450N45 Gas Orifice Kit(Qty 50)Size 46 KGAHA0550N46 See Installation Instructions for model, Gas Orifice Kit(Qty 50)Size 47 KGAHA1550N47 Gas Orifice Kit(Qty 50)Size 48 KGAHA1650N48 altitude, and heat value usages. Gas Orifice Kit(Qty 50)Size 54 KGAHA0650P54 Gas Orifice Kit(Qty 50)Size 55 KGAHA0750P55 Gas Orifice Kit(Qty 50)Size 56 KGAHA0850P56 Gas Orifice Kit(Qty 50)1.25 mm KGAHA5750125 Gas Orifice Kit(Qty 50)1.30 mm KGAHA5750130 * Factory-authorized and field installed.Gas conversion kits are A.G.A./C.G.A.recognized. s 16x25 filters suitable for side return on all furnace sizes. AIR DELIVERY-CFM(With Filter)* RETURN-AIR EXTERNAL STATIC PRESSURE(In.wc) UNIT SIZE SPEED SUPPLY 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Bottom High 1120 1075 1020 960 895 815 720 605 455 340 024045 or Med-High 930 890 850 805 750 680 600 500 345 195 Side(s) Med-Low 820 785 750 700 650 585 505 400 235 --- Low 725 690 655 605 555 495 405 305 --- High 1465 1400 1325 1250 1175 1085 980 860 725 560 Bottom Med-High 1295 1260 1210 1155 1090 1015 930 830 700 545 036045 or Medium 1150 1120 1085 1040 985 920 835 740 620 510 Side(s) Med-Low 1030 1010 980 945 895 835 765 685 570 345 Low 860 835 810 780 745 700 635 555 445 260 Bottom High 1140 1105 1055 1010 955 885 815 715 545 390 024070 Med-High 915 885 855 825 785 725 655 530 420 280 or Med-Low 795 770 740 700 655 600 510 420 325 --- Side(s) Low 690 665 630 590 550 475 415 340 245 --- High 1440 1400 1355 1300 1240 1170 1090 1000 890 745 Bottom Med-High 1180 1165 1150 1125 1085 1030 970 890 785 645 036070 or Medium 1015 1020 1010 990 965 925 875 800 700 560 Side(s) Med-Low 885 885 880 865 845 815 770 700 605 475 Low 1 695 700 700 690 670 640 1 600 540 460 1 345 High 1840 1790 1730 1670 1605 1530 1450 1370 1275 1170 Bottom Med-High 1610 1575 1535 1485 1435 1370 1305 1230 1145 1055 048070 or Medium 1460 1430 1400 1360 1315 1260 1205 1130 1055 965 Side(s) Med-Low 1260 1240 1215 1180 1145 1100 1040 985 915 835 Low 1065 1040 1015 985 955 915 875 825 765 695 Bottom High 1650 1600 1535 1465 1385 1285 1175 1055 895 645 042090 or Med-High 1515 1485 1440 1380 1300 1220 1115 990 830 600 Side(s) Med-Low 1385 1360 1320 1260 1195 1120 1025 915 710 565 Low 1205 1180 1160 1120 1065 1005 925 810 630 510 High 2060 2000 1930 1835 1755 1620 1490 1315 1115 910 Bottom Med-High 1710 1695 1665 1585 1480 1390 1245 1110 955 775 048090 or Medium 1470 1475 1450 1390 1335 1230 1120 1005 855 690 Side(s) Med-Low 1260 1265 1245 1225 1165 1090 995 880 750 600 Low 1030 1025 1020 990 940 890 810 720 615 500 High 2380 2295 2205 2105 2005 1900 1775 1650 1510 1335 Bottom Med-High 2185 2115 2045 1960 1875 1770 1655 1535 1400 1240 Only Medium 1905 1865 1815 1740 1670 1590 1490 1390 1245 1110 Med-Low 1595 1565 1530 1485 1430 1355 1275 1160 1055 920 Low 1340 1310 1280 1225 1170 1120 1040 955 850 750 High 2485 2415 2330 2230 2135 2030 1920 1790 1645 1485 060090 Both Sides or Med-High 2175 2130 2070 2000 1930 1840 1740 1620 1495 1345 15ide&Bottom Medium 1845 1815 1770 1720 1655 1580 1500 1395 1270 1090 Med-Low 1540 1515 1475 1435 1385 1335 1270 1175 1045 915 Low 1280 1250 1220 1190 1155 1105 1035 945 845 745 High 2420 2345 2265 2165 2070 1960 1850 1720 1570 1420 Med-High 2160 2110 2045 1960 1885 1790 1695 1570 1445 1305 1 Side Only Medium 1850 1815 1765 1710 1635 1560 1480 1380 1250 1110 Med-Low 1530 1490 1455 1420 1375 1320 1250 1160 1055 905 Low 1 1290 1250 1220 1 1190 1155 1110 1 1040 950 835 1 740 Bottom High 1625 1575 1515 1445 1355 1260 1165 990 785 595 036110 or Med-High 1510 1470 1415 1355 1285 1185 1070 890 725 530 Side(s) Med-Low 1360 1335 1295 1250 1180 1100 985 810 670 475 Low 1195 1180 1155 1115 1065 980 860 740 605 410 High 2055 1990 1910 1815 1695 1575 1425 1230 1090 910 Bottom Med-High 1750 1725 1670 1605 1515 1400 1255 1120 975 785 048110 or Medium 1545 1525 1490 1445 1355 1260 1135 1020 880 750 Side(s) Med-Low 1300 1290 1275 1235 1165 1085 1005 895 750 620 Low 1050 1045 1015 975 1 935 1 880 1 815 715 610 1 515 * A filter is required for each return-air supply. Airflow performance includes 1"washable filter media such as contained in factory-authorized accessory filter rack. To determine airflow performance without this filter,assume an additional.1 available external static pressure. -Indicates unstable operating conditions. -9- AIR DELIVERY-CFM(With Filter)* RETURN-AIR EXTERNAL STATIC PRESSURE(In.wc) UNIT SIZE SPEED SUPPLY 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 High 2530 2460 2380 2285 2200 2085 1970 1835 1695 1545 Bottom Med-High 2225 2190 2135 2075 1995 1910 1805 1695 1565 1430 Only Medium 1895 1885 1865 1820 1770 1700 1610 1520 1410 1290 Med-Low 1565 1555 1535 1505 1465 1410 1350 1265 1175 1050 Low 1 1320 1295 1265 1235 1205 1160 1105 1035 950 870 Both Sides or High --- --- 2415 2330 2235 2125 1995 1860 1735 1605 066110 1 Side&Bottom Med-High 2205 2175 2120 2065 1975 1900 1790 1685 1580 1460 High 2485 2430 2360 2270 2175 2070 1950 1825 1685 1535 Med-High 2155 2135 2100 2040 1970 1885 1790 1680 1560 1420 1 Side Only Medium 1830 1830 1810 1780 1730 1665 1595 1505 1395 1275 Med-Low 1520 1505 1490 1470 1430 1385 1330 1250 1165 1055 Low 1275 1260 1240 1210 1180 1135 1090 1025 930 840 Bottom High 2090 2010 1930 1835 1710 1590 1470 1335 1025 835 048135 or Med-High 1790 1755 1705 1640 1550 1465 1360 1210 945 785 Side(s) Med-Low 1545 1525 1500 1450 1380 1315 1215 1005 855 670 Low 1325 1320 1295 1265 1210 1150 995 865 745 540 High 2485 2400 2310 2215 2110 2000 1880 1725 1535 1355 Bottom Med-High 2195 2150 2090 2000 1920 1825 1720 1565 1405 1255 Only Med-Low 1880 1850 1820 1780 1715 1635 1540 1415 1290 1160 Low 1640 1635 1615 1585 1530 1465 1370 1255 1150 1040 High --- --- 2385 2305 2195 2085 1960 1825 1670 1465 Both Sides or Med-High 2180 2145 2060 2010 1945 1865 1765 1660 1515 1325 066135 1 Side&Bottom Med-Low 1880 1850 1820 1780 1715 1635 1540 1415 1290 1160 Low 1640 1635 1615 1585 1530 1465 1370 1255 1150 1040 High 2320 2250 2155 2055 1970 1855 1725 1600 1450 1280 1 Side Only Med-High 2125 2065 1995 1910 1815 1710 1610 1490 1340 1175 Med-Low 1845 1825 1765 1710 1650 1570 1475 1370 1240 1100 Low 1640 1620 1580 1540 1485 1410 1330 1220 1080 960 High 2465 2430 2375 2305 2230 2110 2000 1865 1725 1545 Bottom Med-High 2115 2105 2075 2030 1980 1910 1830 1725 1590 1425 Only Med-Low 1800 1790 1770 1735 1695 1640 1570 1465 1345 1225 Low 1570 1565 1551 1525 1495 1445 1370 1270 1175 1070 Both Sides or High --- --- 2375 2285 2200 2105 1995 1870 1730 1570 060155 1Side&Bottom Med-High 2155 2135 2095 2040 1975 1895 1790 1685 1550 1400 1 Side Only High --- --- 2260 2180 2085 1975 1865 1740 1605 1455 Med-High 2140 2095 2040 1975 1890 1810 1705 1595 1480 1325 * A filter is required for each return-air supply. Airflow performance includes 1"washable filter media such as contained in factory-authorized accessory filter rack. To determine airflow performance without this filter,assume an additional.1 available external static pressure. -Indicates unstable operating conditions. -10- -11- SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS I Cancels:PDS 312A.45.1 Heating&Cooling Systems ©2003 Bryant Heating&Cooling Systems,7310 W.Morris St. Indpls.,IN 46231 PRINTED IN U.S.A. Catalog No.5231-202 02-03 BUILDING INSPECTION REPORT — MECHANICAL (RESIDENTIAL) Permit No. 1120 Address: 20301 45th Drive NE Contractor: Washington Energy Owner: Julia Rersnyak Date: 10/10/2016 ® APPROVAL ❑ PARTIAL APPROVAL ❑ CORRECTION ❑ OTHER APPLIANCE: Gas Furnace CO DETECTOR: N HEAT PUMP/AC UNIT: ❑ GAS PIPING: N DISCONNECT: ❑ DRIP LEG: N SEISMIC: ❑ VENTING: N 3" PAD: ❑ ACCESS: N INSULATION/PROTECTION: ❑ SHUT-OFF VALVE: N DUCTS: N/A L&I: Yes Date: 10/10/2016 Inspector: Kevin Olander ' CITY OF ARLINGTON a, 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:20301 451h Drive NF, Permit k;1120 Parcel N:00898600006400 Valuation:0.00 OWNER APPLICANT_ CONTRACTOR Nautc:KELLY MICHAEL A/MAKOUS JULIA H Name:Ethan Onat Name:WASI IINGTON ENERGY SERVICES Address:20301 45TH DR NE Address:3909 19611 St SW Address:3909 196th Street S W City,State Zip:ARLINGTON,WA 98223-4721 City,Stale Zip:Lynnwood,WA 98036 City,Slate Zip.Lynnwood,WA 98036 Phone: Phone:206-378-6927 Phonc:800-398-4663 MECI'IANICAL CONTRACTOR PLUMBING CONTRACTOR Name;WASHINGTON ENERGY SERVICES Noma Addrays:3909 196Ih SIrnG SW Address: City,Sint ,Zip;Lynnwood,WA 9803E City,State.%ip: Phonc.806-398-1663 I'llnew LICN:WASH IESSSINS HXP: 49/7/2017 LICN: EXP: JO40ESCRIPTION PERMIT TYPH: Residential Mechanical CODE YEAR: 2015 STORIES! 2 CONST.TYPE: DWELLING UNITS: I OCLGROUR 130ILDINGS; OCC LOAD. PERMIT APPIWAL. "n34 I A(iltlili'1'OCONIPLY WITI1 CITY AND S'I'A F LAWS REGULA LING CONSTRUC:'HON AND IN Ih IIN6 THIi WORK All1'!IOttIT.t:I� Tl-IFRF.BY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELAXING TO WORKNIEN'S COMPENSATION INSURANCE AND RCW 18,27. TI IIS APPLfCA I ION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OF'FICIAI:OR HIS/I IE1(DEPUTY AND ALL.FEES ARE PAID. IT IS UNLAWFOL TO USE OR OCCUPY A BUILDING OR STRUCTURI:UNTIL A FINAL INSPECTION HAS HFF;N MADE,AND APPROVAL OR A CER I'IF1C'ATLCE:.Sales F OCCUPANCY I[AS BEEN GRANTED. IBC 11011RC 110. , ,KS TA NC tax relating to construction and construction materials in the City of Arlingli a re'rrl-d on your saes tax return form and coded City of r glml 03101. AV SM re Print Name 7 Dale c Sate CONWIONS Adhere to it tallation of model 4 312JAV06070. Duct testing is required per the 2015 Washington Energy Code R402,1.2 THIS I'V I M T AUTHORIZS ONLY ME WORK NO'I'PD_.THIS PIiRMIT COVERS WORK"ro nE DONE ON PRl VA t L:PROPEK%Y ONLY. ANY C'ONSfRUCCION ON THE PUBLIC DOMAIN(CI IRM,$IDI-MALKS,DKIVLbVAYS,MAR01)I'!L N,IirC j WILL REQUIKf`,SI-PARATP,PURMISSION_ PERMIT FEES Date Description Fee Amount 8/12/2016 Furnace $25 00 8/12/2016 Mechanical Permit Base Fee $25.00 Total Due: s50.00 Toted Payment: $50.00 Balance Due: $0,00 CALL FOR INSPECTIONS BUILDING(360)4113-3417 When calling for an inspection please leave the following information: Perinit Number,Type of inspeclion being requested,and whether you prel'er morning or afternoon CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:20301 45th Drive NE Permit#:1120 Parcel#:00898600006400 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:KELLY MICHAEL A/MAKOUS JULIA H Name:Ethan Onat Name:WASHINGTON ENERGY SERVICES Address:20301 45TH DR NE Address:3909 196th St SW Address:3909 196th Street SW City,State Zip:ARLINGTON,WA 98223-4721 City,State Zip:Lynnwood,WA 98036 City,State Zip:Lynnwood,WA 98036 Phone: Phone:206-378-6927 Phone:800-398-4663 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:WASHINGTON ENERGY SERVICES Name: Address:3909 196th Street SW Address: City,State,Zip:Lynnwood,WA 98036 City,State,Zip: Phone:800-398-4663 Phone: LIC#:WASHIES85INS EXP: 9/7/2017 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: 2 CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington re rt on your sales tax return form and coded City of Arlington#3101. oqj Signature Print Name Date UIIRM446fDate CONDITIONS Adhere to installation of model# 312JAV06070. Duct testing is required per the 2015 Washington Energy Code R402.1.2 THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 8/12/2016 Furnace $25.00 8/12/2016 Mechanical Permit Base Fee $25.00 Total Due: $50.00 Total Payment: $50.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon _ �, r �, I 8/12/2016 WASHINGTON ENERGY SVCS CO LLC ) (Search L&I �lor place Ri��iis ;raz�e�; 1-1censing ^ Washington State Department of " Labor & Industries WASHINGTON ENERGY SVCS CO LLC Owner or tradesperson 3909 196TH STREET SW Principals LYNNWOOD,WA 98036 206-282-4700 OLSON,CRAIG E, PARTNERIMEMBER SNOHOMISH County OLSON,VERA A, PARTNER/MEMBER NG,YUN-KWAN WINNIE,AGENT Doing business as WASHINGTON ENERGY SVCS CO LLC WA UBI No. Business type 603 522 032 Limited Liability Company Governing persons CRAIG E OLSON LLC FIRST POINT; VERN A OLSON; FLicense Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. WASHIES851NS Effective—expiration 09/07/2015—09/07/2017 Bond North American Spec Ins Co $12,000.00 Bond account no. 2198899 Received by L&I Effective date 08/10/2015 09/07/2015 Expiration date Until Canceled Insurance United Specialty Insurance Com $1,000,000.00 Policy no. BV01673641 Received by L&I Effective date 04/29/2016 05/01/2016 Expiration date 05/01/2017 Insurance history https://secure.ini.wa.gov/verify/Detail.aspx?UBI=603522032&LIC=WASHIES851NS&SAW= 1/2 _ ' V 8/12/2016 WASHINGTON ENERGY SVCS CO LLC Savings l No savings accounts during the previous 6 ye.' ,,eriod. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations Infraction no. PZETDO0865 Satisfied Issue date RCW/WAC 05/06/2016 18.106.020 Violation city Violation amount LYNNWOOD $250.00 Type of violation PLUMBER INFRACTION Description Contractor employed a person to engage in the trade of plumbing without a current journeyman,specialty or trainee certificate, temporary permit or medical gas endorsement as required. Danny H Padilla Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. This company has multiple workers'comp accounts. Active accounts L&I Account ID Account is current. 224,000-17 Doing business as WENERGY LLC Estimated workers reported Quarter 2 of Year 2016"Greater than 100 Workers" L&I account representative T2/SUSAN BETTS(360)902-4828-Email:BETT235@lni.wa.gov Track this contractor Q Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. ©Washington State Dept.of Labor&Industries.Use of[his site is subject to the laws of the state of Washington, hftps://secure.I ni.wa.gov/verify/Detai l.aspx?U BI=603522032&LIC=WASH I ES851 N S&SAW= 2/2 i RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:20301 45th Dr NE Project Description:Replacing gas furnace Owner: Julia Rersnyak Address: 20301 45th Dr NE City:Arlington StateWA Zip Code: 98223 Phone: 425-780-3075 Email:juliarezrez@gmaii.com Applicant: Ethan Onat Address:3909 196th St SW City: Lynnwood State WA Zip Code: 98036 Phone: 206-378-6927 Email: eonat@washingtonenergy.com CONTRACTOR INFORMATION Contractor Name•Washington Energy Services Address:3909 196th St SW City: Lynnwood State WA Zip Code: 98036 License Number:WASHIES851 NS Expiration: 09/07/17 Phone:206-378-6927 Email:eonat@washingtonenergy.com Received STAFF USE ON � n AUG 11 2016 Permit #: l !mil/ Accepted by: Date: 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES [J� Furnace (80+) Model#312JAV06070 AFUE80% ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping Solid-Fuel Appliance Ill Other Gas Piping Information Not Applicable: 16 Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances 4�r+ wwU+r I0K.e�*,.w cX�«,� Applicant Signature: ----- Date; 08i12i2016 Applicant Printed Name: Ethan Kerem Onat I hereby certify that the above information is correct and that the construction, installation for the above mentioned pr000rty will be in accordance with the applicablslaws_of_the City_of_Arlington_and-the State of_Wash in-ton. 6/16LP Page 2 of 2 Alialm 4-Way Multipoise 312AAV/312JAV Induced Combustion Sizes 045 thru 155 Hating&Coft*shma Gas Furnace Series A The 312AAV/JAV Two-stage 4-way Mulitpoise Gas Furnace offers outstanding comfort in an 80% AFUE furnace. You get the benifits of Perfect HeatT"": reduced drafts, reduced sound levels, longer cycles, less temperature swings between cycles, �� ��■, �' less temperature differences between rooms, and improved indoor air quality. Plus, it features a dehumidify mode and the ability to change 1!!!� eftwom m.o continuous fan speeds from the thermostat. The ! e!mmul e!!mw9 ews 312AAV/JAV furnaces are approved for use with natural or propane gas, and the 312JAV is approved for use in Low NOx Air Management am Districts. P k STANDARD FEATURES • Perfect Heafm operation Two-stage heating Very low operating sound through low-stage operation and noise elimination combustion system Four-position furnace: upflow, horizontal right, horizontal left, downflow Thirteen different vent options Shorter in height-only 33'/3' tall Media Filter Cabinet included Microprocessor based "smart" control center Adapts heating stages to meet demand Continuous Fan speed adjustable from thermostat Adjustable heating air temperature rise LED diagnostics, non-volatile fault code memory, and self test feature ,; • Patented blocked vent safeguard to ensure proper furnace venting A02181 •All models are Chimney Friendly when used with accessory vent kit `°` `e�.� • Insulated blower compartment SA ' Heat pump compatible SP ��. . • Hot surface Ignition (HSI) ��: ,t,n :o� %900, .P�'� • Residential installations eligible for consumer financing through the Comfort REGISTERED QUALITY SYSTEM Credit Program MEETS DOE RESIDENTIAL CONSERVATION LIMITED WARRANTY EFFICIENCY SERVICES PROGRAM STANDARDS. 20-year warranty on "Super STM" heat exchanger RATING CERTIFIED 5-year arts warranty on all other components ama Before purchasing this appliance,read important y p ty p energy cost and efficiency information available from your retailer. Form No. PDS 312A.45.2 �8.718- — 28.1t8" VENT CONNEC7roN) S 114" 1-9/16"— zn� �2Art8' 2 9116" AIRFLOW JUNCTION BOX 19" 13/16" LOCATION D —13/16" F 4-13/16"— OUTLET 7/8'DIA I t ACCESSORY+ V. t. 8.7r16 RIGHT HAND 11/18' 1-1/2"DIA 1/2"DIA THERMOSTAT—,,,," ENTRY GAS ENTRY mill 3-15/16" 112"DIA THERMOSTAT WIRE ENTRY LEFT HAND GAS 1-7116` ENTRY ALTERNATE 33•116 24-719" JUNCTION BOX '7 LOCATION(TYP) VENT OUTLET 5 PLACES(TYP) 14.7/8- 718"DIA ACCESSORY 3-3/4" ( 7l8"DIA ACCESSORY ts_ 21-5/B" ,-11I16" C BOTTOM INLET 4P-1116" 1- 24' — SIDE INLET (CASING) NOTES: 1. Two additional'/a-in.dia knockouts are located in the top plate. 2. Minimum return-air openings at furnace,based on metal duct. If flex duct is used, see flex duct manufacturer's recommendations for equivalent diameters. 3. Minimum return-air opening at furnace: a. For 800 CFM-16-in.round or 14% x 12-in.rectangle. b. For 1200 CFM-20-in.round or 141/2 x 19'/z-in.rectangle. c. For 1600 CFM-22-in.round or 14'6 x 22'1 -in.rectangle. d. For airflow requirements above 1800 CFM,see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets,a combination of 1 side and the bottom,or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM. A 0 E F VENT 312AAV/312JAV (CABINET (SUPPLY (BOTTOM (C.L.TOP& CONNECTION SHIPPING UNIT SIZE WIDTH) WIDTH) RETURN WIDTH) VENTOUTLET) (see notes 1&2)BOTTOM SIZE WEIGHT 024045 14-3i16 12-9/16 12-11116 9-5/16 4 116 036045 14-3/16 12-9115 12-11/16 9-5/16 4 119 024070 14-3/16 12-9116 12-11/16 9-5/16 4 120 036070 14-3/16 12-9116 12-11/16 9-5/16 4 124 048070 17-112 15-7/8 16-1i8 11-9/16 4 138 042090 17-V2 15-7/8 16-1/8 11-9/16 4 136 048090 21 19-3/8 19-1/2 13-5/16 4 151 060090 21 19-3/8 19-1/2 13-5116 4 156 036110 17-1/2 15-7/8 16-1/8 11-9/16 4 144 048110 21 19-3/8 19-1/2 13-5116 4 158 066110 21 19-3/8 19-1/2 13-5116 4 153 048135 21 19-3/8 19-1/2 13-5/16 4(note 1) 163 066135 24-112 22-718 23 15-1/16 4(note i) 174 060155 4- --22-7/8 23 Trsi116 hate-fi 181 1) 135 and 155 size furnaces require five-inch vents. Use a 4-5 inch vent adapter between furnace and vent stack. 2)See Installation Instructions for complete installation requirements. 25" 221. Ai is rw�xe 5d� OW SCe I • CeMrrline�54 ew Sbb (wSt•� Media/ A02210 Filler CabMel A B lb" it" b 20" 21" 20" 24" 25" 24" -2- INSTALLATION MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION DISTANCE MINIMALE EN POLICES AUX CONSTRUCTIONS COMBUSTIBLES This forced air furnace is equipped for use with This furnace is approved for UPFLOW,DOWMFLOW, and natural gas at altitudes 0-10,000 It(0-3,050m) HORIZONTAL installations. An accessory Idt, supplied by the Cette foumaise est approuvee pour I'installation HORIZONTALE rranufacturer,shall be used to convert to propane et la circulation d'air VERS LE HAUT et VERS LE RAS. gas use or may be required for some natural gas Clearance arrows 1" Les fleemes de degagernerr appThis licatithm furnace orientation I'odentatlon de la fournaise. ace is for indoor installation in a do not orange w sh a ne dwVent pas avec building constructed on site. & This furnace may be installed on combustible flooring in alcove or closet at rrinimum clearance as indicated by the diagram from combustible 0" 0" material. A u a c oe This furnace may be used with a Type B-1 Vent R R I E 1 N e �5e �o�e and may be vented in c TF nn with other gas- .e fired appliances. Fora µti m Cette fouaise a air pulse est equipee eP 0"Nit s E pour utilisation aver gaz naturel et altitudes Eym Rv,. comprises entre 0-3,050m(0-10,000 pi). s o` F R R�T i`k Utiliser une trousse de conversion,foumie par col E '''�,"T E'u 3 I le fabricard,pour passer au gaz propane ou pour *0" 3"wr certaines installations au gaz natural. 0 Cette foumaise est prewe pour Care installee clans un batirnent construit stir place. g Clearance in inches Cette foumaise peut titre installee sur oegagement un plancher combustible clans une alcove ou dens un garde-robe an respectant Is minimum d'espaoe Iibre des mat6daux combustibles,tel Vert Clearance to combustibles: qu'indique sur le diagramme. For Single Wall vents 6 inches(6 po). Cette foumaise peut titre utilisee aver un For Type B-1 vent type 1 inch(1 po). conduit d'evacuation de Type B-1 ou connectde D6ga9erneat de 1'event aver combustibles: au conduit common d'autres a IS a Pour conduit d'evaaration a pard simple 6 po(6 inches) pPar� 9az• Pour conduit d'evacuation de TvDe B-1 1 Do(1 inch). MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION DOWNFLOW POSITIONS: t Installation on rrorrconbustible floors only. For Installation on combustible flooring only when installed on special base,Part No.KGASBO201ALL, Cal Assembly,Part No. CD5 or CK5,or Cal Casing,Part No.KCAKC. 0 18 inches front clearance required for alcove. * Indicates supply or return sides when furnace is in the horizontal position.Line contact only permissible between lines formed by intersections of the Top and two Sides of the furnace jacket,and building joists, studs or framing. DEGAGEMENT MINIMUM EN POUCES AVEC ELEMENTS DE CONSTRUCTION COMBUSTIBLES POUR LA POSITION COURANT DESCENDANT: t Pour('installation sur plancher non combustible seulemrent. Pour l'installation sur un plancher corrbustible seulement quand on utilise la base sp6dale,pieoe n° KGASBO201ALL, I'ensemble serpentin,piece n° CD5 ou CK5,ou Is carter de serpentin,piece n° KCAKC. 0 Dans une alcove,on doit mairtenir un d6gagemert a I'avant de 18 po(450 mm). * La position indiqu6e conceme le cote d•entree ou de retou quand la foumaise est clans la position horizortale. Le contact nest permis qu'entre les lignes formees par Ies intersections du dessus et des deux cotes de la chernise de la foumaise et Ies wives,mhontant sous cadre de charpente. 327590-101 REV. B CONTROLS-THERMOSTATS AND ZONING Auto Changeover,°F/°C,1-Stage Heat/1-Stage Cool-TSTATBBNAC01-B Auto Changeover,°F/°C,2-Stage Heat/1-Stage Cool-TSTATBBNHP01-B THERMOSTAT-NON-PROGRAMMABLE Auto Changeover,°FNC,2-Stage Heat/2-Stage Cool-TSTATBBN2S01-B in AC Mode,3-Stage HeaU2-Stage Cool in HP Mode Air Conditioner,1-Stage Heat/1-Stage Cool,Manual Changeover,"FNC-TSTATBBBAC01 Heat Pump,2-Stage HeaN1-Stage Cool,Manual Changeover,°FNC-TSTATBBBHP01 Auto Changeover,7-Day Programmable,"FNC, 1-Stage Heat/1-Stage Cool-TSTATBBPACO I-B Auto Changeover,7-Day Programmable,`F/°C,2-Stage Heat/1-Stage Cool-TSTATBBPHP01-B Auto Changeover,7-Day Programmable,°FNC,2-Stage Heat/2-Stage Cool-TSTATBBP2S01-B THERMOSTAT-PROGRAMMABLE in AC Mode,3-Stage Heat/2-Stage Cool in HP Mode Dual Fuel Thermostat,includes Outdoor Air Temperature Sensor-TSTATBBPDF01-B ' Thermidistat Control-Non-Programmable/Programmable Thermostat-TSTATBBPRHOI-B with Humidity Control(For use in Dual Fuel,AC,HP,and 2S applications.Includes Outdoor Air Temperature Sensor.) ZONING-2-ZONE ZONEBB2KIT01-B,ZONEKIT2ZBDP ZONING-4-ZONE 70NEBB4KIT01-B ZONING-8-ZONE ZONEBBBKIT01-B 'Do not use in zoning heat pump applications. -3- SPECIFICATIONS UNIT SIZE 024045 036045 024070 036070 048070 042090 048090 RATINGS ■ PERFORMANCE 312JAV U flow:all 312AAV -High 44,000 44.000 66.000 66.000 66,000 88,000 88,000 Input Btuh* -Low 29,000 29,000 43,500 43,500 43,500 58,000 58,000 Nonweatherized ICS 312JAVDownflow/Horizontal-High 42,000 42,000 63,000 63,000 63,000 84,000 84,000 -Low 29.000 29,000 43,500 43,500 43,500 58,000 58,000 312JAV U flowf all 312AAV -High 35,000 36,000 54,000 54.000 53,000 71,000 71,000 Uutput Capacity(Btuh)t -Low 23,000 23,000 36,000 36,000 35,000 47,000 47,000 Nonweatherized ICS -High 34,000 34,000 51,000 51,000 51,000 68,000 68,000 -Low 23,000 23,000 36.000 36,000 35.000 47,000 47,000 AFUE t 80.0 80.0 80.0 60.0 80.0 80.0 80.0 Certified Temperature Rise Range°F High 30-60 20-50 40-70 30-60 25-55 40-70 30-60 Low 20-50 15-45 30-60 30-60 15-45 25-55 25-55 Certified External Static Pressure HeaUCool 0.10/0.50 0.10/0.50 0.12/0.50 0.1210.50 0.12/0.50 0.15/0.50 0.151050 Airflow CFM HeatingHigh/Low 820/725 1030/860 790/685 885/695 1570/1045 1375/1195 1265030 Cooling 895 1175 955 1240 1605 1385 1755 Ft Fr.TRlr.Al Unit Volts-Hertz-Phase 115-60-1 Operating Voltage Range Min-Max 104-127 Maximum Unit Amps 5.4 7.1 5.1 7.3 10.1 8.1 9.9 Maximum Wire Length(Measured 1 Way in Ft) 49 38 51 37 27 34 1 28 Minimum Wire Size 14 Maximum Fuse or Ckl Bkr Size(Amps)** 15 Trarisfurrner(24v) 40va External Control Heating 12va Power Available Cooling 35va Air Conditioning Blower Relay Standard CONTROLS Limit Control SPST Heating Blower Control Solid-State Time Operation Burners(Monoport) 2 2 3 3 3 4 4 Gas Connection Size 1/2-in.NPT GAS r.nNTRni White Rodgers Gas Valve(Redundant) Min Inlet Pressure(In.we) 4.5(Natural Gas) Max Inlet Pressure(In.wc) 13.6(Natural Gas) Ignition Device Hot Surface Direct-Drive Motor HP(PSC) 1/5 1/3 1/5 1/3 1/2 1/3 112 Motor Full Load Amps 2.8 5.1 2.8 5.1 7.4 5.1 7.4 RPM(Nominal)-Speeds 1075-4 1075-5 1075-4 1075-5 1 1075-5 1 1076-4 1075-5 Blower Wheel Diameter x Width In. 10 x 6 10 x 6 10 x 6 10 x 6 I 11 x 8 1 10 x 8 10 x 10 *Gas input ratings are certified for elevations to 2000 ft.For elevations above 2000 ft,reduce ratings 4 percent for each 1000 ft above sea level.Referto National Fuel Gas Code Table F4 or furnace Installation Instructions.In Canada,derate the unit 10 percent for elevations 2000 ft to 4500 ft above sea level. Time-delay type is recommended, tCapacity in accordance with U.S.Government DOE test procedures. $Airflow shown is for bottom only return-air supply for the as-shipped speed tap.For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required for each return-air supply. An airflow reduction of up to 7%may occur when using the factory-specified 4-5/16-inch wide,high efficiency media filter. ICS-Isolated Combustion System N/A-Not Applicable -4- SPECIFICATIONS UNIT SIZE 060090 036110 048110 066110 1 048135 066135 060155 RATINGS AND PERFORMANCE U flow;all 312AAV -High BB,000 110,000 110,000 110,000 132,000 132,000 154,000 Input Btuh* -Low 58,000 72,500 72,500 72,500 87,000 87,000 101,500 Nonweatherized ICS 312JAVDownflow/Horizontal-High 84,000 105,000 105,000 105,000 126,000 126,000 147,000 -Low 58,000 72,500 72,500 72,500 87,000 87,000 101,500 312JAV U flow•all 312AAV -High 71,000 89.000 89,000 89.000 107,000 107.000 124,000 Output Capacity(Btuh)t -Low 47.000 59,000 59.000 59,000 70.000 70,000 82.000 Nonweatherized ICS 312JAVDownflowlHorizontal-Hi h 1 2 1W.000 119,000 -Low 47.000 59,000 59,000 59,000 70,000 70,000 82,000 AFUE t 80.0 80.0 80.0 80.0 80.0 80.0 80.0 Certified Temperature Rise Range°F High 25-55 4 -7 0- 50-80 4 -7 45-75 Low 30-60 30-60 Certified External Static Pressure Heat/Cool 0.15/0.50 0.20J0.50 0.20/0.50 0.20/0.80 0.20/0.50 0.20/0.50 0.20/0.50 Airflow CFM$ HeatingHigh/Low 1580/1325 1335/1180 1290/1045 1555/1295 1525/1320 1865/1640 1790/1565 Cooling 1 2005 1 1355 1695 2200 1710 2110 2230 ELECTRICAL Unit Volts-Hertz-Phase 115-60-1 Operating Voltage Range Min-Max 104-127 Maximum Unit Amps 12.8 8.1 10.1 13.6 10.0 14.4 15.0 Maximum Wire Length(Measured 1 Way in Ft) 34 34 27 32 28 31 29 Minimum Wire Size 12 14 12 14 12 Maximum Fuse or Ckt Bkr Size(Amps)" 20 15 20 15 20 Transformer(24v) 40va External Control Heating 12va Power Available Cooling 35va Air Conditionin Blower Rela Standard CONTROLS Limit Control I SPST Heating Blower Control Solid-State Time O eration Burners(Monoport) 4 5 5 5 6 6 7 Gas Connection Size 1/2-in.NPT GAS CONTROLS White Rodgers Gas Valve(Redundant) Min Inlet Pressure(In.wc) 4.5 Natural Gas Max Inlet Pressure(In.wc) 13.6 Natural Gas) Ignition Device Hot Surface BLOWERDATA Direct-Drive Motor HP(PSC) 3/4 1/3 1/2 314 1/2 3/4 1 3/4 Motor Full Load Amps 11.0 5.2 7.4 11.0 7.9 11.1 11.1 RPM Nominal)-Speeds 1075-5 1075-4 1075-5 1075-5 1075-4 1075-4 1075-4 Blower Wheel Diameter x Width(In.) 11 x 11 10 x 8 10 x 10 11 x 11 10 x 10 11 x 11 11 x 11 * :j Gas input ratings are certified for elevations to 2000 ft.For elevations above 2000 ft,reduce ratings 4 percent for each 1000 ft above sea level.Referto National Fuel Gas Code Table F4 or furnace Installation Instructions.In Canada,derate the unit 10 percent for elevations 2000 ft to 4500 ft above sea level. Time-delay type is recommended. t Capacity in accordance with U.S.Government DOE test procedures. $Airflow shown is for bottom only return-air supply for the as-shipped speed tap.For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required for each return-air supply. An airflow reduction of up to 7%may occur when using the factory-specified 4-5/16-inch wide,high efficiency media filter- ICS-Isolated Combustion System N/A-Not Applicable -5- i �I =i 1 AI SEE NOTES:1,2,4,7,8,9 SEE NOTES:1,2,3,4,7,8,9 SEE NOTES:1,2,4,5,7,8,9 UPFLOW UPFLOW DOWNFLOW A02058 A02059 A02061 - i 1 F O 1 0 Q / I 1( t I I _ 1 SEE NOTES:1,2,3,4,5,7,8,9 SEE NOTES:1,2,3,4,5,7,8,9 SEE NOTES:1,2,4,5,6,7,8,9 DOWNFLOW DOWNFLOW DOWNFLOW A02060 A02063 A02062 Venting Notes 1. For common vent, vent connector sizing and vent material: United States, latest edition of the National Fuel Gas Code(NFGC),ANSI Z223.1/NFPA 54. In Canada, latest edition of the National Standards of Canada, Natural Gas and Propane Installation Code(NSCNGPIC), CSA B149.1-00. 2. Immediately increase to 5-inch vent connector outside furnace casing when 5-inch vent connector required, refer to Note 1. 3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace,except when KGAVG0101 DFG is used in downflow position. 4.Type B vent where required, refer to Note 1. 5.4"single wall vent must be used inside furnace casing and the KGAVG0101 DFG Downflow Vent Guard Kit. 6.Accessory Downflow Vent Guard Kit, KGAVG0101 DFG required in downflow installations with bottom vent configuration. 7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kit, KGACA02014FC and KGACA02015FC for sizing and complete application details. 8. Secure vent connector to furnace elbow with(2)corrosion-resistant sheet metal screws,space approximately 1801 apart. Secure-atf-othersingte-waf-ventconnectorjoints with-(3)-corrosion-res istant screws-spaced-approximately 1200 apart. Secure Type B vent connectors per vent connector manufacturer's recommendations. -6- uluiiP 4==Y _ O 0 i Jll 11 SEE NOTES:1,2,4,5,7,8,9 HORIZONTAL RIGHT SEE NOTES:1,2,4,5,7,8,9 HORIZONTAL RIGHT A02068 A02070 � - J i SEE NOTES:1,2,4,7,8,9 HORIZONTAL RIGHT A02069 ii7udi t 9 o SEE NOTES:1,2,4,7,8,9 HORIZONTAL LEFT SEE NOTES:1,2,4,5,7,8,9 A02064 HORIZONTAL LEFT A02065 uTw ur a o � O .e SEE NOTES:1,2,4,5,7,8,9 SEE NOTES:1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT A02067 A02066 -7- FACTORY-AUTHORIZED . ACCESSORIES DESCRIPTION PART NO. 024045 036M 024070 CM70 049070 042090 048090 060090 036110 04e110 G66110 048135 086135 060155 EZ Flex Media Filter with end EXPXXUNVO016 x x x x x x x caps-16 i n.(9 pack) EZ Flex Media Filter with end EXPXXUNVO020 x x x x x caps-201 n.(9 pack) EZ Flex Media Filter with end EXPXXUNVO024 x x caps-241 n.(6 pack) Replacement EZ Flex Filler-16 EXPXXFIL0016 x x x x x x x In.(10 pack) Replacement EZ Flex Filter-20 EXPXXFIL0020 x x x x x in.(10 pack) Replacement EZ Flex Filter-24 EXPXXFIL0024 x x in (10 pack) Unframed filter,one inch-16x25 KGAWF1301 UFR x x x x x x s s x s s s s s KGAWF1306UFR(6-pack) Unframed filter,one inch- KGAWF1401 UFR 20x25 x x x x x KGAWF1406UFR(6 pack) Unframed filter,one inch- KGAWF1501 UFR x x 24x25 KGAWF1506UFR(6 pack) Twinning Kit KGATW0601HSI x x x x x x x x x x x x x x Combustible Floor Base(not required when evaporator coil KGASB0201ALL x x x x x x x x x x x x x x case is used) Downflow Vent Guard(not required when vent is routed KGAVG0101 DFG x x x x x x x x x x x x x x through cabinet) Vent Extension Kit(may be used when vent is routed through KGAVE0101 DNH x x x x x x x x x x x x x x cabinet in downflow) Chimney Adapter Kit-4 i nch Kr,ACAn2n r.1AF Y Y Y Y Y Y Y vent -_ Chimney Adapter Kit-5 i nch KGACA02015FC x x x vent Natural-to-Propane Gas * KGANP2901ALL x x x x x x x x x x x x x x Conversion Kit(Single Kit) Propane-to-Natural Gas KGAPN2301ALL x x x x x x x x x x x x x x Conversion Kit(Single Kit) Gas Orifice Kit(Qty 50)Size 42 KGAHAO15ON42 Gas Orifice Kit(Qty 50)Size 43 KGAHA025ON43 Gas Orifice Kit(Qty 50)Size 44 KGAHA035ON44 Gas Orifice Kit(Qty 50)Size 45 KGAHA045ON45 Gas Orifice Kit(Qty 50)Size 46 KGAHA0550N46 See Installation Instructions for model, Gas Orifice Kit(Qty 50)Size 47 KGAHA1550N47 Gas Orifice Kit(Qty 50)Size 48 KGAHA1650Na6 altitude, and heat value usages. Gas-Orifice-Kit(Qty 50)-Size-54 -KGAHA0650P54 — Gas Orifice Kit(Qty 50)Size 55 KGAHA075OP55 Gas Orifice Kit(Qty 50)Size 56 KGAHAO85OP56 Gas Orifice Kit(Qty 50)1.25 mm KGAHA5750125 Gas Orifice Kit(Qty 50)1.30 mm KGAHA5750130 * Factory-authorized and field installed.Gas conversion kits are A.G.A./C.G.A.recognized. s 16x25 filters suitable for side return on all furnace sizes. -8_ AIR DELIVERY-CFM(With Filter)* S UNIT SIZE PEED RETURN-AIR EXTERNAL STATIC PRESSURE(In.wc) SUPPLY 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Bottom High 1120 1075 1020 960 895 815 720 605 455 340 024045 or Med-High 930 890 850 805 750 680 600 500 345 195 Side(s) Med-Low 820 785 750 700 650 585 505 400 235 — Low 725 690 655 605 555 495 405 305 — -- High 1465 1400 1325 1250 1175 1085 980 860 725 560 Bottom Med-Nigh 1295 1260 1210 1155 1090 1015 930 830 700 545 036045 or Medium 1150 1120 1085 1040 985 920 835 740 620 510 Side(s) Med-Low 1030 1010 980 945 895 835 765 685 570 345 Low 860 835 810 1 780 745 700 1 635 555 1 445 260 High 1140 1105 1055 1010 955 885 815 715 545 390 Bottom 024070 or Med-High 915 885 855 825 785 725 655 530 420 280 Side(s) Med-Low 795 770 740 700 655 600 510 420 325 — Low 690 665 630 590 550 475 415 340 245 — High 1440 1400 1355 1300 1240 1170 1090 1000 890 745 Bottom Med-High 1180 1165 1150 1125 1085 1030 970 890 785 645 036070 or Medium 1015 1020 1010 990 965 925 875 800 700 560 Side(s) Med-Low 885 885 880 865 845 815 770 700 605 475 Low 695 700 700 690 670 640 600 540 460 345 High 1840 1790 1730 1670 1605 1530 1450 1370 1275 1170 Bottom Med-High 1610 1575 1535 1485 1435 1370 1305 1230 1145 1055 048070 or Medium 1460 1430 1400 1360 1315 1260 1205 1130 1055 965 Side(s) Med-Low 1260 1240 1215 1180 1145 1100 1040 985 915 835 Low 1065 1040 1015 985 955 915 875 825 765 695 Bottom High 1650 1600 1535 1465 1385 1285 1175 1055 895 645 042090 or Med-High 1515 1485 1440 1380 1300 1220 1115 990 830 600 Side(s) Med-Low 1385 1360 1320 1260 1195 1120 1025 915 . 710 565 Low 1205 1180 1160 1 1120 1065 1005 1 925 810 630 510 High 2060 2000 1930 1835 1755 1620 1490 1315 1115 910 Bottom Med-High 1710 1695 1665 1585 1480 1390 1245 1110 955 775 048090 or Medium 1470 1475 1450 1390 1335 1230 1120 1005 855 690 Side(s) Med-Low 1260 1265 1245 1225 1165 1090 995 880 750 600 Low 1030 1025 1020 990 940 890 810 720 615 500 High 2380 2295 2205 2105 2005 1900 1775 1650 1510 1335 Bottom Med-High 2185 2115 2045 1960 1875 1770 1655 1535 1400 1240 Only Medium 1905 1865 1815 1740 1670 1590 1490 1390 1245 1110 Med-Low 1595 1565 1530 1485 1430 1355 1275 1160 1055 920 Low 1340 1310 1 1280 1225 1170 1 1120 1040 955 1 850 750 High 2485 2415 2330 2230 2135 2030 1920 1790 1645 1485 Both Sides or Med-High 2175 2130 2070 2000 1930 1840 1740 1620 1495 1345 060090 1 Side&Bottom Medium 1845 1815 1770 1720 1655 1580 1500 1395 1270 1090 Med-Low 1540 1515 1475 1435 1385 1335 1270 1175 1045 915 Law 1280 1250 1220 1190 1155 1105 1035 945 845 745 High 2420 2345 2265 2165 2070 1960 1850 1720 1570 1420 Med-High 2160 2110 2045 1960 1885 1790 1695 1570 1445 1305 1 Side Only Medium 1850 1815 1765 1710 1635 1560 1480 1380 1250 1110 Med-Low 1530 1490 1455 1420 1375 1320 1250 1160 1055 905 Low 1290 1250 1220 1 1190 1155 1110 1 1040 950 1 835 740 Bottom High 1625 1575 1515 1445 1355 1260 1165 990 785 595 036110 or Med-High 1510 1470 1415 1355 1285 1185 1070 890 725 530 Side(s) Med-Law 1360 1335 1295 1250 1180 1100 985 810 670 475 Low 1195 1180 1155 1115 1065 980 860 740 605 410 High 2055 1990 1910 1815 1695 1575 1425 1230 1090 910 Bottom Med-High 1750 1725 1670 1605 1515 1400 1255 1120 975 785 048110 or Medium 1545 1525 1490 1445 1355 1260 1135 1020 880 750 Side(s) Med-Low 1300 1290 1275 1235 1165 1085 1005 895 750 620 Low 1 1050 1 1045 1015 1 975 935 880 1 815 1 715 610 1 515 * A filter is required for each return-air supply.Airflow performance includes 1"washable filter media such as contained in factory-authorized accessory filter rack. To determine airflow performance without this Filter,assume an additional.1 available external static pressure. -Indicates unstable operating conditions. -9- AIR DELIVERY-CFM(With Filter)* RETURN-AIR EXTERNAL STATIC PRESSURE(In.wc) UNIT SIZE SPEED SUPPLY 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 High 2530 2460 2380 2285 2200 2085 1970 1835 1695 1545 Bottom Med-High 2225 2190 2135 2075 1995 1910 1805 1695 1565 1430 Only Medium 1895 1885 1865 1820 1770 1700 1610 1520 1410 1290 Med-Low 1565 1555 1535 1505 1465 1410 1350 1265 1175 1050 Low 1320 1295 1265 1235 1205 1160 1105 1035 950 870 Both Sides or High — — 2415 2330 2235 2125 1995 1860 1735 1605 066110 1Side&Bottom Med-High 2205 2175 2120 2065 1975 1900 1790 1685 1580 1460 High 2485 2430 2360 2270 7175 2070 1950 1825 1685 1535 Med-High 2155 2135 2100 2040 1970 1885 1790 1680 1560 1420 1 Side Only Medium 1830 1830 1810 1780 1730 1665 1595 1505 1395 1275 Med-Low 1520 1505 1490 1470 1430 1385 1330 1250 1165 1055 Low 1275 1260 1240 1210 1180 1135 1090 1025 930 840 Bottom High 2090 2010 1930 1835 1710 1590 1470 1335 1025 835 048135 or Med-High 1790 1755 1705 1640 1550 1465 1360 1210 945 785 Side(s) Med-Low 1545 1525 1500 1450 1380 1315 1215 1005 855 670 Low 1 1325 1320 1295 1265 1210 1150 1 995 865 745 540 High 2485 2400 2310 2215 2110 2000 1880 1725 1535 1355 Bottom Med-High 2195 2150 2090 2000 1920 1825 1720 1565 1405 1255 Only Med-Low 1880 1850 1820 1780 1715 1635 1540 1415 1290 1160 Low 1640 1635 1615 1585 1530 1465 1370 1255 1150 1040 High — — 2385 2305 2195 2085 1960 1825 1670 1465 Both Sides or Med-High 2180 2145 2060 2010 1945 1865 1765 1660 1515 1325 066135 1Side&Bottom Med-Low 1880 1850 1820 1780 1715 1635 1540 1415 1290 1160 Low 1640 1635 1615 1585 1530 1465 1370 1255 1150 1040 High 2320 2250 2155 2055 1970 1855 1725 1600 1450 1280 1 Side Only Med-High 2125 2065 1995 1910 1815 1710 1610 1490 1340 1175 Med-Low 1845 1825 1765 1710 1650 1570 1475 1370 1240 1100 Low 1640 1620 1580 1540 1485 1410 1330 1220 1080 960 High 2465 2430 2375 2305 2230 2110 2000 1865 1725 1545 Bottom Med-High 2115 2105 2075 2030 1980 1910 1830 1725 1590 1425 Only Med-Low 1800 1790 1770 1735 1695 1640 1570 1465 1345 1225 Low 1570 1565 1551 1525 1 1495 1445 1 1370 1270 1175 1070 Both Sides or High — -- 2375 2285 2200 2105 1995 1 1870 1730 1570 060155 1Side&Bottom Med-High 2155 2135 2095 2040 1975 1895 1790 1685 1550 1400 1 Side Only High — — 2260 2180 2085 1975 1865 1740 1605 1455 Med-High 2140 2095 2040 1975 1890 1810 1705 1595 1480 1325 A filter is required for each return-air supply. Airflow performance includes V washable filter media such as contained in factory-authorized accessory filter rack. To determine airflow performance without this filter,assume an additional.1 available external static pressure. -Indicates unstable operating conditions. -10- -11- SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS 1 tl Cancels:PDS 312A.45.1 "11g&Codug*d ma 02003 Bryant Heating&Cooling Systems,7310 W.Mords St Indpls.,IN 46231 PRINTED IN U.S.A. Catalog No.5231-202 02-03 Permit#: 1120 Permit Date: 08/12/16 Permit Type: RESIDENTIAL MECHANICAL Project Name: Julia Rersnyak Applicant Name: Ethan Onat Applicant Address: 3909 196th St SW Applicant, City, State, Zip: Lynnwood, WA 98036 Contact: Ethan Onat Phone: 206-378-6927 Email: eonat@washingtonenergy.com Scope of Work: Replace Gas Furnace Valuation: 0.00 Square Feet: 0 Number of Stories: 2 Construction Type: Occupancy Group: ID Code: Permit Issued: 08/12/2016 Permit Expires: 02/12/2017 Form Permit Type: Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning KELLY MICHAEL 00898600006400 20301 45TH DR NE A/MAKOUS JULIA Residence Single Family sidence-Detached H Contractors Contractor Primary Contact Phone Address Contractor Type License License# WASHINGTON Karen Matheney 2063786648 3909 196th Street CONSTRUCTION COA 603 522 032 ENERGY SERVICES SW CONTRACTOR WASHINGTON Karen Matheney 2063786648 3909 196th Street CONSTRUCTION Labor&WASHIES85INS ENERGY SERVICES SW CONTRACTOR Industries Fees Fee Description Notes Amount Forced Air Heat fee per Btu $25.00 Mechanical Base Permit Fee $25.00 Total $50.00 Attached Letters Date Letter Description 08/12/2016 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 08/12/2016 Craig Olson 60832241 cc $50.00 Outstanding Balance $0.00 Notes Date Note Created By: 08/12/2016 Model#312JAV06070 AFUE 80% Kristin Foster Uploaded Files Date File Name 10/12/2016 1889917-20301 45th Drive NE.docx 08/12/2016 1785518-1120 Issued Permit.pdf 08/12/2016 1785435-1120 Apnlication.pdf