HomeMy WebLinkAbout3204 Smokey Point Dr_BLD826_2026 Model Number YSC060E3EMA**C00000000300000000000000000 Customer : . Project : . Name : . YSC060E3EMA0047 General Unit function DX cooling, gas heat Unit efficiency Standard efficiency Airflow Convertible configuration Airflow Application Downflow Design Airflow 2000 Evaporator rows 4.00 Fresh air selection Econ-dry bulb 0-100% 3hp Evaporator fin spacing 192 Evaporator face area 7.71 Tonnage 5 Ton Evaporator face velocity 259 Min. unit operating weight 613.0 Cooling Entering DB 80.00 Max. unit operating weight 824.0 Cooling Entering WB 67.00 Ent Air Relative Humidity 51.08 ASHRAE 90.1 Yes Ambient Temp 95.00 Rated capacity (AHRI) 60.00 Heating capacity Medium gas heat 3ph Heating EAT 70.00 Voltage 208-230/60/3 Design ESP 0.500 Major design sequence E - R-410A Main Cooling Tonnage 5 Ton Cooling Entering DB 80.00 Cooling Entering WB 67.00 Ent Air Relative Humidity 51.08 Ambient Temp 95.00 Evap Coil Leaving Air Temp (DB) 57.73 Evap Coil Leaving Air Temp (WB) 56.93 Cooling Leaving Unit DB 59.56 Cooling Leaving Unit WB 57.63 Gross Total Capacity 62.27 Gross Sensible Capacity 48.11 Gross Latent Capacity 14.16 Net Total Capacity 59.10 Net Sensible Capacity 44.94 Net Sensible Heat Ratio 0.76 Fan motor heat 3.17 Dew Point 56.41 Refrig charge (HFC-410A) - ckt 1 9.4 Saturated Discharge Temp Circuit 1 121.07 Saturated Suction Temp Circuit 1 52.21 Main Heating Heating capacity Medium gas heat 3ph Input Heating Capacity 80000.00 Output Heating Capacity 64000.00 Output Heating Cap. w/Fan 67171.27 Heating EAT 70.00 Heating LAT 99.90 Heating Delta T 29.90 Motor/Electrical Page 1 Voltage 208-230/60/3 Design ESP 0.500 Component SP 0.180 Total Static Pressure 0.680 Field supplied drive kit required None Indoor mtr operating power 0.964 Indoor RPM 1076 Indoor Motor Power 0.72 Outdoor Motor Power 402.6 Compressor Power 4.34 System Power 5.46 SEER @ AHRI 13.00 MCA 27.40 MOP 40.00 Compressor 1 RLA 15.90 Compressor 2 RLA 0.00 Condenser fan FLA 2.50 Evaporator fan FLA 5.00 Exhaust fan power 0.870 DX Cooling, Gas Heat 3-10 Ton Unit controls Electro mechanical controls 3ph Refrigeration controls Frostat and crankcase heater 3ph Page 2 Y4C Job Information . . . Tag YSC060E3EMA0047 Quantity 1 Model number YSC060E3EMA**C00000 00030000000000000000 0 Meets Unit Information Tonnage 5 Ton Unit function DX cooling, gas heat Min. unit operating weight 613.0 lb Max. unit operating weight 824.0 lb Design Airflow 2000 cfm Cooling Information Gross Total Capacity 62.27 MBh Gross Sensible Capacity 48.11 MBh Gross Latent Capacity 14.16 MBh Net Total Capacity 59.10 MBh Net Sensible Capacity 44.94 MBh Net Sensible Heat Ratio 0.76 Number Cooling Entering DB 80.00 F Cooling Entering WB 67.00 F Cooling Leaving Unit DB 59.56 F Cooling Leaving Unit WB 57.63 F Ambient Temp 95.00 F Heating Information Heating capacity Medium gas heat 3ph Input Heating Capacity 80000.00 Btuh Output Heating Capacity 64000.00 Btuh Heating EAT 70.00 F Heating LAT 99.90 F Heating Delta T 29.90 F Motor/Electrical Information Voltage 208-230/60/3 Design ESP 0.500 in H2O Indoor Motor Power 0.72 kW Indoor mtr operating power 0.964 hp Indoor RPM 1076 rpm Outdoor Motor Power 402.6 W Compressor Power 4.34 kW System Power 5.46 kW MCA 27.40 A MOP 40.00 A Compressor 1 RLA 15.90 A Evaporator fan FLA 5.00 A Condenser fan FLA 2.50 A Electrical values provided are estimated only and are subject to change without notice and may differ from nameplate values . Field installed low or high static drive kits may be needed. Please check the fan performance tables in the product catalog for application ranges. 12/26/2014 Page 1 of 1 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 General The units shall be convertible airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 115°F and 40°F. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil-faced, fire-retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8 inch, foil-faced, closed-cell insulation. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8 inch high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double-hemmed and gasket-sealed. The ribbed top adds extra strength and enhances water removal from unit top. Filters Throwaway filters shall be standard on all units. Optional 2-inch MERV 8 and MERV 13 filters shall also be available. Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Dual compressors are outstanding for humidity control, light load cooling conditions and system back-up applications. Dual compressors are available on 7½-10 ton models and allow for efficient cooling utilizing 3-stages of compressor operation for all high efficiency models. Notes: Crankcase heaters are optional on YSC (036, 048, 060, 072, 090, 102, 120); standard on YHC (036, 048, 060, 072, 092, 102, 120). Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120E, T/YHC092,102, 120E). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3-5 ton units (standard efficiency 3-phase or high efficiency 3-phase with optional motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3-5 ton units (1-phase or high efficiency 3-phase) have multispeed, direct drive motors. All 6-8½ ton units (standard efficiency) shall have belt drive motors with an adjustable idler-arm assembly for quick-adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All 10 tons and 7½-8½ (high efficiency) have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. The microchannel type condenser coil is standard for the T/YSC 10 ton models and 7½ ton high efficiency models. The microchannel type condenser coil is not offered on the 7½ ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube-to-fin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all-aluminum microchannel coils also help to reduce the unit weight. All-aluminum construction improves re-cyclability. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A removable, reversible, double-sloped condensate drain pan with through the base condensate drain is standard. Page 11 Controls Unit shall be completely factory-wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24V control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized microprocessor shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection. 24-volt electromechanical control circuit shall include control transformer and contactor High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory-installed as standard. An area shall be provided for replacement suction line driers. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field-installed kit) and also comply with the California requirement for low NOx emissions (Gas/Electric Only). Economizer This accessory shall be available with or without barometric relief. The assembly includes fully modulating 0-100 percent motor and dampers, minimum position setting, preset linkage, wiring harness with plug, spring return actuator and fixed dry bulb control. The barometric relief shall provide a pressure operated damper that shall be gravity closing and shall prohibit entrance of outside air during the equipment off cycle. Optional solid state or differential enthalpy control shall be available for either factory or field installation. The economizer arrives in the shipping position and shall be moved to the operating position by the installing contractor. Frostat This option is to be utilized as a safety device. The Frostat opens when temperatures on the evaporator coil fall below 10°F. The temperature will need to rise to 50°F before closing. This option should be utilized in low airflow or high outside air applications. (Cooling with Electric Heat Only.) Frostat This option is to be utilized as a safety device.The Frostat opens when temperatures on the evaporator coil fall below 10°F.The temperature will need to rise to 50°F before closing.This feature should be utilized in low airflow or high outside air applications (cooling only). Page 12 Permit #: 826 Permit Date: 10/23/15 Permit Type: COMMERCIAL MECHANICAL Project Name: Center Pointe Building, LLC Applicant Name: Smith Mechanical Applicant Address: 6146 Portal Way Applicant, City, State, Zip: Ferndale, WA 98248 Contact: Jared Murphy Phone: 360-815-6947 Email: jmurphy@smithmechanical.com Scope of Work: New RTU on existing roof curb Valuation: 18000.00 Square Feet: 0 Number of Stories: 1 Construction Type: Occupancy Group: ID Code: Permit Issued: 10/29/2015 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Launa Black Property Parcel # Address Legal Description Owner Name Owner Phone Zoning CENTERPOINTE 539 Other Retail 00645300000601 3204 SMOKEY POINT DR BUILDING LLC Trade NEC Contractors Contractor Primary Contact Phone Address Contractor Type License License # CONSTRUCTION Smith Mechanical Brad Ludwigsen 360 384 3203 6146 Portal Way COA 602003351 CONTRACTOR CONSTRUCTION Labor & Smith Mechanical Brad Ludwigsen 360 384 3203 6146 Portal Way SMITHMI004CA CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status R15. HVAC installation & duct 11/06/2015 MECHANICAL 11/06/2015 11/06/2015 BUILDING Approved sealing approved FINAL C10. 11/06/2015 MECHANICAL 11/06/2015 BUILDING Approved ROUGH-IN Plan Reviews Date Review Type Description Assigned To Review Status COMMERCIAL 10/23/2015 BUILDING MECHANICAL Fees Fee Description Notes Amount Gas Piping/Units Enter # of units $10.00 Mechanical Fee (Enter Fixture Fee) $25.00 Mechanical Base Permit Fee $25.00 Mechanical Commercial Plan Review Table 4-1 $250.00 Total $310.00 Attached Letters Date Letter Description 10/27/2015 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 10/29/2015 Centerpointe Building, LLC check #3312 Launa Black $310.00 Outstanding Balance $0.00 Uploaded Files Date File Name 01/22/2016 1435061-0110_001.pdf 01/22/2016 1435057-0109_001.pdf 01/22/2016 1435054-0108_001.pdf 10/29/2015 1344929-826_Issued Permit.pdf 10/23/2015 1337383-Mechanical Site Plan.pdf 10/23/2015 1337384-Mechanical_Permit_Application_CVXz0bKZy9DL3b.pdf 10/23/2015 1337385-3204_Dabestani TI mechanical plan.pdf 10/23/2015 1337386-3204_YSC060E3EMA0047_Submittal.pdf Google Maps https://www.google.com/maps/@48.1543418,-122.1869938,77m/data=!...    ✔ ✔ 3204 Smokey Point Dr. Set RTU on existing curb and install ductwork install for TI 18000 The Dabestani Group 360-653-9899 3204 Smokey Pt Dr Suite 202 Arlington WA 98223 mallorie@dabestanigroup.com Jared Murphy 360-815-6947 6146 Portal Way Ferndale WA 98248 jmurphy@smithmechanical.com Smith Mechanical 360-384-3203 6146 Portal Way Ferndale WA 98248 jmurphy@smithmechanical.com 1/29/16 SMITHMI004CA 1 1 10/21/2015 Jared Murphy