HomeMy WebLinkAbout420 STILLAGUAMISH AVE_BLD1039_2026 420 Stilliguamish Ave Installation of new Heat Pump System Dale Cranmore 420 Stilliguamish Ave Arlington WA. 98223 360-435-2855 N/A Ken Salo 2120 Pacific Everett Wa 98201 425-252-3114 ken@essmwa.com Evergreen State Heat and AC 2120 Pacific Everett WA. 98201 EVERGSS022OT 10/10/17 425-252-3114 ken@essmwa.com 4TWV0024A1000B 10 ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ 06/01/2016 Ken Salo Submittal Variable Speed ComfortLink™ II Heat Pump 4TWV0024A1000A TAG:______________________________ SAFETY WARNING Onlyqualifiedpersonnel shouldinstallandservicetheequipment.Theinstallation,startingup,andservicingofheating,ventilating,andair- conditioningequipmentcanbehazardousandrequiresspecificknowledgeandtraining.Improperlyinstalled,adjustedoralteredequipment byanunqualifiedperson couldresultindeathor seriousinjury.Whenworkingontheequipment,observeallprecautionsintheliterature andonthetags,stickers,andlabelsthatareattachedtotheequipment. September 2013 4TWV0024A-SUB-1 ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. SERVICE PANEL LIQUID LINE SERVICE VALVE, “E” I.D. FEMALE BRAZED CONNECTION WITH 1/4” SAE FLARE PRESSURE TAP FITTING. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 (12”) FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED GAS LINE SERVICE VALVE, “D” I.D. FEMALE BRAZED CONNECTION WITH 1/4” SAE FLARE PRESSURE TAP FITTING. ELECTRICAL SERVICE PANEL 25 (1) 22.2 (7/8) DIA. HOLE LOW VOLTAGE 28.6 (1-1/8) DIA. K.O. WITH 22.2 (7/8) DIA. HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPPLY LIQUID LINE SERVICE VALVE, “E” I.D. FEMALE BRAZE CONNECTION WITH 1/4” SAE FLARE PRESSURE TAP FITTINGS. GAS LINE 1/4 TURN BALL SERVICE K.O. FOR ALTERNATE VALVE, “D” I.D. FEMALE BRAZED CONNECTION ELECTRICAL ROUTING WITH 1/4” SAE FLARE PRESSURE TAP FITTING. Model Base A B C D E F G H J K 1219 829 756 143 92 210 79 1035 4TWV0024A 3 16–5/8 10–3/8 (48) (32–5/8) (29–3/4) (5–5/8) (3–5/8) (8–1/4) (3–1/8) (40–3/4) SOUND POWER LEVEL A-WeightedSound FullOctaveSoundPower[dB] Model Mode Speed PowerLevel[dB(A)] 63Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz Cool Min 54 70.9 50.3 51.8 52.3 50.4 42.0 37.7 39.9 Cool Max 65 76.3 65.2 62.7 64.1 60.5 55.7 49.5 45.0 4TWV0024A Heat Min 60 69.8 52.9 52.8 57.5 55.2 51.9 47.4 46.5 Heat Max 69 75.9 66.0 64.7 67.3 65.6 57.0 52.2 47.7 Note:RatedinaccordancewithAHRIStandard270–2008 2 4TWV0024A-SUB-1 OUTDOORUNIT(a)(b) 4TWV0024A1000A Mechanical Specification Options POWERCONNS.—V/PH/HZ(c) 208/230/1/60 General MIN.BRCH.CIR.AMPACITY 17.0 The Outdoor Units are charged from the factory for BR.CIR.PROT.RTG.—MAX.(AMPS) 25 matched indoor section and up to 15 feet of piping. This unit is designed to operate at outdoor ambient COMPRESSOR SCROLL temperatures from 55° F to 120° F in cooling and from NO.USED—NO.SPEEDS 1–VARIABLE —10° F to 66° F in heating. Only AHRI approved indoor R.L.AMPS(d)—L.R.AMPS 11.5—10.2 matches are approved for use with these models. FACTORYINSTALLED ComfortLink™ II STARTCOMPONENTS(e) NA This outdoor unit contains the ComfortLink™ II digital INSULATION/SOUNDBLANKET YES communication with 2 wire connection to outdoor and Plug-n-Play set up. COMPRESSORHEAT YES OUTDOORFAN Casing DIA.(IN.)—NO.USED 23—1 Unit casing is constructed of heavy gauge. G60 galvanized steel and painted with a weather-resistant TYPEDRIVE—NO.SPEEDS DIRECT—VARIABLE powder paint on all louvers, panels, prepaint on all CFM@0.0IN.W.G.(f) 2680 other panels. Corrosion and weatherproof CMBP-G30 NO.MOTORS—HP 1—1/3 DuraTuff™ base. MOTORSPEEDR.P.M. 200—1200 Refrigerant Controls VOLTS/PH/HZ 208/230/1/60 Refrigeration system controls include condenser fan, F.L.AMPS 2.8 compressor contactor and high and low pressure switches. A factory supplied, field installed filter is OUTDOORCOIL—TYPE SPINEFIN™ standard. ROWS—F.P.I. 1—24 Compressor FACEAREA(SQ.FT.) 19.77 Inverter driven scroll compressor with 25 to 100% TUBESIZE(IN.) 3/8 output capacity on heat pumps and 30 to 100% output REFRIGERANT R410–A capacity on air conditioners. Noise enclosure LBS.—R-410A(O.D.UNIT)(g) 7lb—6oz minimizes sound levels and built in compressor protection protects compressor will reduce operating FACTORYSUPPLIED YES speed and current draw to maintain operation while LINESIZE—IN.O.D.GAS(h) 5/8 protecting the compressor. LINESIZE—IN.O.D.LIQ.(h) 3/8 Condenser Coil CHARGINGSPECIFICATIONS The Spine Fin™ outdoor coil provides low airflow SUBCOOLING 10° resistance and efficient heattransfer. The coil is DIMENSIONS HXWXD protected on all four sides by louvered panels. CRATED(IN.) 51.6X30.1X33 Low Ambient Cooling WEIGHT As manufactured, this system has built in freeze SHIPPING(LBS.) 227 protection that will allow cooling operation below 55°F but will reduce capacity or shut down completely to NET(LBS.) 206 prevent operation under adverse conditions. (a) CertifiedinaccordancewiththeAir-SourceUnitaryAir-conditioner Equipmentcertificationprogram,whichisbasedonAHRIstandard Comfort Control 210/240. The 950/850 Control is required and provides Plug-n- (b) RatedinaccordancewithAHRIstandard270. (c) CalculatedinaccordancewithNatl.Elec.Codes.UseonlyHACR Play setup and 3 wire connection. circuitbreakersorfuses. (d) ThisvalueshownforcompressorRLAontheunitnameplateandon thisspecificationsheetisusedtocomputeminimumbranchcircuit ampacityandmax.fusesize.Thevalueshownisthebranchcircuit selectioncurrent. (e) NAmeansnostartcomponents.Yesmeansquickstartkit components.PTCmeanspositivetemperaturecoefficientstarter. (f) StandardAir—DryCoil—Outdoor (g) Thisvalueapproximate.Formoreprecisevalueseeunitnameplate. (h) Max.linearlength150ft.;Max.lift—Suction50ft.;Max.lift—Liquid 50ft. 4TWV0024A-SUB-1 3 Notes Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.Trane.com. Tranehasapolicyofcontinuousproductandproductdataimprovementsandreservestherighttochangedesignandspecificationswithoutnotice. ©2013Trane 4TWV0024A-SUB-1 13Sep2013 Supersedes(New) BUILDING INSPECTION REPORT – MECHANICAL (RESIDENTIAL) Permit No. 1039 Address: 420 Stillaguamish Ave Contractor: Evergreen State Heat and A/C Owner: Dale Cranmore Date: 6/21/2016 ☒ APPROVAL ☐ PARTIAL APPROVAL ☐ CORRECTION ☐ OTHER APPLIANCE: Heat Pump CO DETECTOR: ☒ HEAT PUMP/AC UNIT: ☒ GAS PIPING: ☐ DISCONNECT: ☒ DRIP LEG: ☐ SEISMIC: ☒ VENTING: ☐ 3” PAD: ☒ ACCESS: ☒ INSULATION/PROTECTION: ☒ SHUT-OFF VALVE: ☐ DUCTS: N/A L&I: Yes Date: 6/21/2016 Inspector: Kevin Olander Permit #: 1039 Permit Date: 06/01/16 Permit Type: RESIDENTIAL MECHANICAL Project Name: Dale Cranmore Applicant Name: Evergreen State Heat and A/C Applicant Address: 2120 Pacific Ave Applicant, City, State, Zip: Everett, WA 98201 Contact: Ken Salo Phone: 425-252-3114 Email: ken@essmwa.com Scope of Work: Install new heat pump Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 06/01/2016 Permit Expires: 12/01/2016 Form Permit Type: Status: COMPLETE Assigned To: Kristin Foster Property Parcel # Address Legal Description Owner Name Owner Phone Zoning 420 STILLAGUAMISH CRANMORE DALE 111 Single Family 00411600200502 AVE L Residence - Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License # EVERGREEN STATE CONSTRUCTION Mark Payne 425-252-3114 2120 Pacific Ave COA 601-724-357 HEAT & A/C CONTRACTOR EVERGREEN STATE CONSTRUCTION Labor & Mark Payne 425-252-3114 2120 Pacific Ave EVERGSS022OT HEAT & A/C CONTRACTOR Industries Fees Fee Description Notes Amount Mechanical Base Permit Fee $25.00 Mechanical Fee (Enter Fixture Fee) $25.00 Total $50.00 Attached Letters Date Letter Description 06/01/2016 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 06/08/2016 Russell Kimball 59963219 cc $50.00 Outstanding Balance $0.00 Notes Date Note Created By: 06/08/2016 Emailed permit for signature. KF Kristin Foster 06/01/2016 Heat Pump Model #4TWV0024A1000B 10 HSPE Kristin Foster Uploaded Files Date File Name 06/21/2016 1687480-420 Stillaguamish Ave.docx 06/13/2016 1671674-1039_Permit.pdf 06/01/2016 1652602-1039_Application.pdf 06/01/2016 1652603-1039_Specs.pdf