Loading...
HomeMy WebLinkAbout18660 58th Ave NE_BLD983_2026 ✔ 18660 58th Ave. NE 7500.00 19 1550 Stoddard International, LLC (360)435-6455 18660 58th Ave. NE Arlington Wa 98223 Gary Coltes (206)622-4656 (206)718-0908 gary.coltes@vikingsprinkler.net 3434 1st Ave. S. Seattle Wa. 98134 Viking Fire Protection (206)622-4656 3434 1st Ave. S. Seattle Wa. 98134 VIKINAS373NT 12/2016 04/19/2016 Gary Coltes Page 1 of 7 MICROMATIC® STANDARD TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION The Viking Micromatic® Standard Response Pendent VK102 Sprinkler is a small, ther- mosensitive, glass-bulb spray sprinkler available in several different finishes and tem- perature ratings to meet design requirements. The special Polyester, and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive at- mospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves the ENT coating as corrosion resistant. FM Global has no approval classification for Polyester coatings as corrosion resistant.) Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 VdS Approved: Certificate G414006 & G414004 LPCB Approved CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and UL Design Criteria on page 4 for cULus Listing requirements, and refer to Approval Chart 2 and FM Design Criteria on page 5 for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)† Maximum Working Pressure: 175 psi (12 bar) wwp Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2” NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4” (57 mm) † cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). Viking Technical Data may be found on The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). The Viking Corporation’s Web site at Material Standards: http://www.vikinggroupinc.com. Frame Casting: Brass UNS-C84400 or QM Brass The Web site may include a more recent Deflector: Phosphor Bronze UNS-C51000†† or Copper UNS-C19500 Bulb: Glass, nominal 5 mm diameter edition of this Technical Data Page. Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT coated Sprinklers: Belleville Spring - Exposed, Screw and Pipcap - ENT plated. ††Not for FM Approval. Ordering Information: (Also refer to the current Viking price list.) Order Micromatic® Standard Response Pendent VK102 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, Wax Coated = C, Wax Over Polyester = V-/W, ENT = JN Form No. F_031414 16.03.04 Rev 16.1 Replaces Form No. F_031414 Rev 15.3 (Removed Black PTFE) Page 2 of 7 MICROMATIC® STANDARD TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 212 °F (100 °C) = M, 286 °F (141 °C) = G, 360 °F (182 °C) = H, 500 °F (260 °C) = L, OPEN = Z (PTFE only). For example, sprinkler VK102 with a 1/2” thread, Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12987AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the “Sprinkler Accessories” section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000). B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B* (available since 2006) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool** Part No. 15915 (available since 2010.) D. Wrench for Wax Coated Sprinklers: Part No. 13577W/B* (available since 2006) *A ½” ratchet is required (not available from Viking). **Allows use from the floor by attaching a length of 1” diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Micromatic® Standard Response Pendent Sprinkler VK102 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Form No. F_031414 16.03.04 Rev 16.1 Page 3 of 7 MICROMATIC® STANDARD TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating1 Ceiling Temperature2 Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Extra High 360 °F (182 °C) 300 °F (149 °C) Mauve Ultra High3 500 °F (260 °C) 465 °F (240 °C) Black Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings4: White Polyester and Black Polyester in all temperature ratings. ENT in all temperature ratings ex- cept 135 °F (57 °C). Wax-Coated Brass and Wax over Polyester5 for sprinklers with the following temperature ratings: 155 °F (68 °C) Lt. Brown Wax 175 °F (79 °C) Brown Wax 200 °F (93 °C) Brown Wax 212 °F (100 °C) Dk. Brown Wax5 286 °F (141 °C) Dk. Brown Wax5 Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), response time may be severely retarded. 4 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. 5 Wax melting point is 170 °F (76 °C) for 212 °F (100 °C) and 286 °F (141 °C) temperature rated sprinklers. Protective Sprinkler Wrench Flat Clip Protective Sprinkler Cap Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_031414 16.03.04 Rev 16.1 Page 4 of 7 MICROMATIC® STANDARD TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 1 (UL) Micromatic® Standard Response Pendent Sprinkler VK102 Maximum 175 PSI (12 bar) WWP Sprinkler Thread Size Nominal Overall Length Listings and Approvals3 Base Part SIN K-Factor (Refer also to UL Design Criteria.) Number1 NPT BSP U.S. metric2 Inches mm cULus4 VdS LPCB 8 Standard Orifice 12987 VK102 1/2” 15 mm 5.6 80.6 2-1/4” 57 A1, B4, B1Y, C5, D3, E6, G6Z A2 A2, B4, B2Y F2, G2Y -- E7 12989 VK102 -- 15 mm 5.6 80.6 2-1/4” 57 A1, B4, B1Y, C5, D3, E6, G6Z A2 A2, B4, B2Y F2, G2Y -- -- NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 10139 VK102 1/2” 15 mm 5.6 80.6 2-1/4” 57 A1, B4, B1Y, C5, D3, E6, G6Z -- -- -- -- -- 10173 VK102 -- 15 mm 5.6 80.6 2-1/4” 57 A1, B4, B1Y, C5, D3, E6, G6Z A2 A2, B4, B2Y -- -- -- 18020 VK102 1/2” 15 mm 5.6 80.6 2-1/4” 57 A1, B4, B1Y, C5, D3, E6, G6Z A2 A2, B4, B2Y F2, G2X F29, 10 -- Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C), and 360 Approved Finishes °F (182 °C) 1 - Brass, Chrome, White Polyester5,6, and Black Approved Escutcheons B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 Polyester5,6 X - Recessed with the Viking Micromatic® Model °C), and 200 °F (93 °C) 2 - Brass, Chrome, White Polyester6, and Black Polyester6 E-1, E-2, or E-3 Recessed Escutcheon C - 286 °F (141 °C) 3 - Brass and Chrome Y - Standard surface-mounted escutcheon or the D - 500 °F (260 °C)7 4 - Wax-Coated Brass and Wax Over Polyester5 Viking Microfast® Model F-1 Adjustable Escutcheon E - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 5 - High Temperature 200 °F (93 °C) Wax Coating (corro- or recessed with the Viking Micromatic® Model E-1, E-2, or E-3 Recessed Escutcheon °C), 286 °F (141 °C), 360 °F (182 °C), and 500 sion resistant); maximum ambient temperature allowed at °F (260 °C)7 ceiling = 150 °F (65 °C) Z - Standard surface-mounted escutcheon or re- cessed with the Viking Micromatic® Model E-1 F - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 6 - ENT5 °C), 286 °F (141 °C), and 360 °F (182 °C) 7 - Chrome G - 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) Footnotes 1 Base part number is shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. 7 Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. 8 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-0021. 9 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. 10 MED Certified, RINA Certificate No. MED497705C5. DESIGN CRITERIA - UL (Also refer to Approval Chart 1.) cULus Listing Requirements: The Viking Micromatic® Standard Response Pendent Sprinkler VK102 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light, Ordinary, and Extra Hazard occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_031414 16.03.04 Rev 16.1 Page 5 of 7 MICROMATIC® STANDARD TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 (FM) Micromatic® Standard Response Pendent Sprinkler VK102 Maximum 175 PSI (12 bar) WWP Sprinkler Base Thread Size Nominal K-Factor Overall Length FM Approvals3 SIN Part Number1 NPT BSP U.S. metric (Refer also to Design Criteria below.) 2 Inches mm Standard Orifice 12987 VK102 1/2” 15 mm 5.6 80.6 2-1/4” 57 A1, B2, C3, D1, E4, G1Y, G4Z 12989 VK102 -- 15 mm 5.6 80.6 2-1/4” 57 A1, B2, C3, D1, E4, G1Y, G4Z NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 10139 VK102 1/2” 15 mm 5.6 80.6 2-1/4” 57 A1, B2, C3, D1, E4, G1Y, G4Z 10173 VK102 -- 15 mm 5.6 80.6 2-1/4” 57 A1, B2, C3, D1, E4, G1Y, G4Z 18020 VK102 1/2” 15 mm 5.6 80.6 2-1/4” 57 A1, B2, C3, D1, G1Y Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 212 °F (100 °C), 286 °F (141 °C), and 360 °F (182 °C) Approved Finishes Approved Escutcheons B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F 1 - Brass, Chrome, White Polyester4, and Y - Standard surface-mounted escutch- (93 °C), and 212 °F (100 °C) Black Polyester4 eon or the Viking Microfast® Model F-1 C - 286 °F (141 °C) 2 - Wax-Coated Brass (corrosion resistant) Adjustable Escutcheon or recessed with the D - 500 °F (260 °C)5 3 - High Temperature 200 °F (93 °C) Wax Viking Micromatic® Model E-1, E-2, or E-3 Coating (corrosion resistant); maximum am- Recessed Escutcheon E - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F 5 bient temperature allowed at the ceiling = Z - Standard surface-mounted escutcheon (141 °C), 360 °F (182 °C), and 500 °F (260 °C) 150 °F (65 °C) or re- cessed with the Viking Micromatic® F - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) 4- ENT6 Model E-1 G - 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) Footnotes 1 Base part number is shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 Other colors are available on request with the same Approvals as the standard colors. 5 Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. 6 FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2.) FM Approval Requirements: The Viking Micromatic® Standard Response Pendent Sprinkler VK102 is is FM Approved as standard response Non-Storage pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_031414 16.03.04 Rev 16.1 Page 6 of 7 MICROMATIC® STANDARD TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Sprinkler wrench 13655W/B** for recessed pendent sprinklers ** A 1/2” ratchet is required (not available from Viking) Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Step 1: Carefully slide the wrench sideways around the deflector, ensuring engage- ment with the sprinklger wrench flats. Wax Coated Pendent Sprinkler Sprinkler wrench 13577W/B** must be used for installing wax coated sprinklers. ** A 1/2” ratchet is required Step 2: Carefully press the wrench upward and ensure engagement with the sprinkler wrench (not available from Viking) flats. Figure 3: Wrench 13577W/B for Wax Coated Sprinklers Form No. F_031414 16.03.04 Rev 16.1 Page 7 of 7 MICROMATIC® STANDARD TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Ceiling Opening Size: 2-5/16” (59 mm) minimum 1/2” 2-1/2” (64 mm) maximum (15 mm) NPT 2-1/8” (54 mm) 1-1/2” 2-3/16” 1-3/4” 2” (38 mm) (56 mm) (51 mm) Min. (45 mm) Max. Installed with a standard Installed with a Microfast Note: At maximum, adapter is 1/8” surface-mounted Model F-1 Adjustable exposed 1/2” (13 mm) from face escutcheon Escutcheon of ceiling Figure 4: Sprinkler Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Ceiling Opening Size: 2-5/16” (59 mm) minimum 2-1/2” (64 mm) maximum 2-1/8” 2-1/8” (54 mm) (54 mm) 1-1/8” 1-1/8” 1-3/4” (29 mm) 2”” (29 mm) (45 mm) Min. (51 mm) Min. Max. Max. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 5: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_031414 16.03.04 Rev 16.1 Replaces Form No. F_031414 Rev 15.3 (Removed Black PTFE) Permit #: 983 Permit Date: 04/20/16 Permit Type: FIRE SPRINKLER Project Name: Stoddard International Applicant Name: Viking Fire Protection Applicant Address: 3434 1st Ave S. Applicant, City, State, Zip: Seattle, WA 98134 Contact: Gary Coltes Phone: 206-718-0908 Email: gary.coltes@vikingsprinkler.net Scope of Work: Sprinkler addition/alteration Valuation: 7500.00 Square Feet: 1550 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 04/29/2016 Permit Expires: 10/29/2016 Form Permit Type: Status: LASERFICHE Assigned To: Kristin Foster Property Parcel # Address Legal Description Owner Name Owner Phone Zoning Stoddard 0235820 18660 58TH AVE NE International Contractors Contractor Primary Contact Phone Address Contractor Type License License # VIKING FIRE 3434 FIRST AVE CONSTRUCTION 206-622-4656 Labor & Industries VIKINAS373NT PROTECTION SOUTH CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status FS07. FIRE 06/14/2016 Approved SPRINKLER FINAL Plan Reviews Date Review Type Description Assigned To Review Status 04/20/2016 FIRE SPRINKLER BUILDING No comments for this review. 04/20/2016 FIRE SPRINKLER PW-WAT-REV Gus 04/20/2016 FIRE SPRINKLER no issues z.Tom Cooper Fees Fee Description Notes Amount Fire System Plan Review Table 4-1 $100.00 Fire Sprinkler System Commercial NFPA 13/13R $192.45 Total $292.45 Attached Letters Date Letter Description 04/29/2016 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 05/03/2016 Gary Coltes 59452517 cc $292.45 Outstanding Balance $0.00 Uploaded Files Date File Name 05/06/2016 1608090-Permit.pdf 04/20/2016 1576436-BLD_983 Plans.pdf 04/20/2016 1576120-BLD_983 Application.pdf 04/20/2016 1576119-BLD_983 Tech Data.pdf