HomeMy WebLinkAbout18410 63rd Ave Ne_BLD6717_2026 Inspection DAILY FIELD REPORT Date AAR TESTING AND INSPECTION, INC. 10/13/2025 Report 7126 180th Ave NE, Suite C101, Redmond, WA 98052 | 425-881-5812 Number BAV101325B CLIENT INFORMATION PROJECT INFORMATION Contact Project No. 25-644 Company Project Name Address Address City City Contractor Five Star Mechanical Permit No. 6717 INSPECTION TYPE(S) STRUCTURE(S) / LOCATION(S) Structural Steel Welding Roof Support Angle and Deck Puddle Welds - Grid C.8/5.5. Weather Temperature (°F) Start Time End Time Sunny 55 12:00 PM 01:30 PM DRAWINGS / DOCUMENTS REFERENCED AHBL drawing/S1.1, 4/S4.2. AWS D1.1. INSPECTION OBSERVATION / REMARKS 1. I received a WABO welder card from Jerard J. Kolrud #W05085 expiration date 4/1/2026 of Northwest Erection & Fab. 2. I inspected the welds of new L5x5x5/16 L angles around penetration and cross member as shown on detail 4/S4.2. 3. 2" of bearing both sides and ends of angles with 3/16" fillet welds. Added clips in corners of cross member and welded all around with 3/16" fillet welds. 4. I observed decking welded with 5/8" diameter at valley bottoms to angle cross member. The decking pieces were also crimped. 5. The welds are visually acceptable according to AWS D1.1 visual acceptance criteria. Items inspected are in conformance with approved plans, specifications, and jurisdictional requirements Inspectors Inspectors Name Report Date Reviewers Reviewed By Reviewed Date Signature Brian Valukonis 10/13/2025 Signature Teajalam (TJ) Gounden e068c8ffca5bd98f-1760224347275 Inspection DAILY FIELD REPORT Date AAR TESTING AND INSPECTION, INC. 10/13/2025 Report 7126 180th Ave NE, Suite C101, Redmond, WA 98052 | 425-881-5812 Number BAV101325B PHOTOS Detail 4/S4.2. The roof opening. The 2" long fillet welded on the angle at a roof joist. The cross member Inspectors Inspectors Name Report Date Reviewers Reviewed By Reviewed Date Signature Brian Valukonis 10/13/2025 Signature Teajalam (TJ) Gounden e068c8ffca5bd98f-1760224347275 Inspection DAILY FIELD REPORT Date AAR TESTING AND INSPECTION, INC. 10/13/2025 Report 7126 180th Ave NE, Suite C101, Redmond, WA 98052 | 425-881-5812 Number BAV101325B Decking underside. A5/8" puddle weld. Inspectors Inspectors Name Report Date Reviewers Reviewed By Reviewed Date Signature Brian Valukonis 10/13/2025 Signature Teajalam (TJ) Gounden e068c8ffca5bd98f-1760224347275 Inspection DAILY FIELD REPORT Date AAR TESTING AND INSPECTION, INC. 10/13/2025 Report 7126 180th Ave NE, Suite C101, Redmond, WA 98052 | 425-881-5812 Number BAV101325B Crimped decking. Inspectors Inspectors Name Report Date Reviewers Reviewed By Reviewed Date Signature Brian Valukonis 10/13/2025 Signature Teajalam (TJ) Gounden e068c8ffca5bd98f-1760224347275 CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 18410 63RD AVE NE Permit #: 6717 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 31052200101000 DATE OF ISSUANCE. Scope of Work: Install factory made venting on a furnace Valuation: 104000.00 OWNER APPLICANT CONTRACTOR CASTING OPERATIONS LLC Five Star Mechanical Five Star Mechanical 21218 76TH AVE S 7509 Grange ST West 7509 Grange St. West KENT, WA 98032 Lakewood, WA 98499 Lakewood, WA 98499 206-786-8278 206-786-8278 LIC: 601 937 083 EXP: 03/31/2026 LIC: FIVESM*010JT EXP: 05/01/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC #: EXP: LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL MECHANICAL CODE YEAR: 2021 STORIES: 1 CONST. TYPE: llA DWELLING UNITS: OCC GROUP: B; Business BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 10/23/2025 Applicant Signature Date Building Official Date CONDITIONS Adhere to approved plans. Permit shall be onsite for inspection. Call for inspections. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/23/2025 Web Only - Mechanical Commercial Plan Review $995.40 10/23/2025 Credit Card Service $29.86 10/23/2025 Processing/Technology $25.00 10/23/2025 Ductwork/Dryer Duct $25.00 10/23/2025 Gas Piping/Units $15.00 10/23/2025 Credit Card Service $1.95 Total Due: $1,092.21 Total Payment: $1,092.21 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail COMMERCIAL MECHANICAL APPLICATION Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping and must be accompanied by ELECTRONIC CONSTRUCTION DRAWINGS and CUT SHEETS and/or information outlined in the MECHANICAL SUBMITTAL REQUIREMENTS, if applicable. Type of Permit:  New Installation  Addition  Alteration  Replaced  Gas Piping Type I and Type II Hood Systems required submittal of the Commercial Mechanical Addenda Property Address: Project Valuation: Lot #: Parcel ID No.: Preferred Contact:  Owner  Contractor Project Description: Owner Name: Office No.: Email Address: Cell No.: Mailing Address: City: State: Zip: Contractor Name: Office No.: Email Address: Cell No.: Mailing Address: City: State: Zip: L&I Contractor License Number: Expiration Date: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured per IFGS, Section 415 • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of each appliance Gas Piping Specification and complete Schematic PAGE 3  Not Applicable  CSST Brass Other Proposed Piping Material: Black Steel Galvanized Steel Proposed Piping Size: ½”  ⅝”  ¾”  1”  1½”  2” Inlet Pressure: Pressure Drop: Specific Gravity: I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulation of the State of Washington. Signature Print Name Date REV03.2022 Page 1 of 3 MECHANICAL PERMIT FEES (per unit) Type of Fixture No. of Units Cost per Unit Subtotal Additional Plan Review fees x $ 75.00 = $ Air Conditioning Unit ≤ 100 Btu/h x $ 15.00 = $ Air Conditioning Unit > 100 Btu/h x $ 25.00 = $ Air Conditioning Unit > 500 Btu/hp x $ 50.00 = $ Air Handling Units x $ 15.00 = $ Base Mechanical Fee $ 25.00 $ 25.00 Boiler <100Btu/h >3hp x $ 15.00 = $ Boiler >1 million Btu/h<50hp x $ 25.00 = $ Boiler >1.5 million Btu/h<50hp x $ 50.00 = $ Boiler >100Btu/h 3-15hp x $ 15.00 = $ Boiler >500Btu/h 15-30hp x $ 25.00 = $ Commercial Hoods -Type I x $ 25.00 = $ Commercial Hoods -Type II x $ 50.00 = $ Diffusers x $ 15.00 = $ Dryer Ducting x $ 15.00 = $ Ductwork (drawings required) x $ 25.00 = $ Evaporative Coolers x $ 15.00 = $ Exhaust/Ventilation Fans x $ 15.00 = $ Fireplace/Insert/Stove x $ 15.00 = $ Forced Air Heat ≤100 Btu/h x $ 15.00 = $ Forced Air Heat >100 Btu/h x $ 25.00 = $ Gas Clothes Dryer x $ 15.00 = $ Gas Fired Air Conditioning Unit ≤ 100 Btu/h x $ 15.00 = $ Gas Fired Air Conditioning Unit > 100 Btu/h x $ 25.00 = $ Gas Fired Air Conditioning Unit > 500 Btu/hp x $ 50.00 = $ Gas Piping ≤ 5 units x $ 15.00 = $ Gas Piping for each additional unit > 5 x $ 2.00 = $ Heat Exchangers x $ 15.00 = $ Heat Pump-Condensing Unit x $ 25.00 = $ Hot Water Heat Coils x $ 15.00 = $ Miscellaneous Appliance - regulated by $ 15.00 $ x = mechanical code, not otherwise specified Package Units ≤ 100 Btu / > 100 Btu x $ 25.00/$50.00 = $ Range/Cook top-Gas Fired x $ 15.00 = $ Refrigeration Unit ≤100Btu/h x $ 15.00 = $ Refrigeration Unit >100Btu/h x $ 25.00 = $ Refrigeration Unit >500Btu/h x $ 50.00 = $ Re-inspection fee (all) x $ 75.00 = $ Unit Heaters ≤ 100 Btu/h x $ 15.00 = $ Unit Heaters >100 Btu/h x $ 25.00 = $ Variable Air Volume Boxes (part of Air $ 10.00 $ x = Conditioning System) Wall Heaters - Gas Fired x $ 25.00 = $ Water Heater - Gas Fired x $ 25.00 = $ Permit Fee $ Table 4-8; Plan Review Fee $ Processing/Technology Fee $25.00 Total $ REV2.2024 Page 2 of 3 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY  SCHEMATIC IS TO SCALE  SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated REV2.2024 Page 3 of 3 WEATHER CAP 3 44'-8 4 5 42'-8 PETTICOAT & SCREEN BY OTHERS 8 3 8'-2 4 5 6'-4 8 ROOF CURB BY OTHERS 8 5 37'-8 8 3 THIMBLE BY OTHERS 3016 BOTTOM OF OD ROOF DECK 5 32'-8 8 7 22'-1 8 UNINSULATED STACK NOTE: THE ENTIRE UNLINED STACK 3 34 MAX OD IS PAINTED TEMPERKOTE 850 16 HIGH TEMP SILVER 5 27'-8 8 AIR BREAK 5 22'-8 8 3 20'-8 4 35'-10 3 15'-8 4 AFTERBURNER CONTROL/EXCESS TEMP THERMOCOUPLE 3 3 20'-8 10'-84 4 INSULATED AFTERBURNER DRAWING SUBMITTED FOR APPROVAL 3 APPROVED AS SUBMITTED 5'-8 4 APPROVED WITH CHANGES RE-SUBMIT FOR REFERENCE ONLY SIGNATURE DATE 0 3 3 62 62 16 16 A0 06/10/25 KJS FOR APPROVAL No. DATE BY DESCRIPTION REVISION UNINSULATED STACK G.A. TITLE NOTICE: THIS PRINT IS OUR SC UNISULATED STACK GENERAL ARRANGEMENT PROPERTY AND SUBJECT TO 3/8" = 1' - 0" APPROX. 7,500 LBS. RETURN UPON DEMAND. ALL DRN RIGHTS OF DESIGN AND (1 REQ'D.) . INVENTION ARE RESERVED. KJS 06/10/25 SHEET DWG No REV TRU-HEAT BURNOUT FURNACE - 7 X 8 X 4 1 15660 LASALLE ST SOUTH HOLLAND IL 60473 CUST 1 17968GA2 A0 (708) 339-6810 www.armilcfs.com BLUE CASTINGS (ARLINGTON, WA) SHEET 1 OF 1 , 17968GA2 - Uninsulated Stack General Arrangement, 6/10/2025 4:08:33 PM WEATHER CAP 3 44'-8 4 5 42'-8 PETTICOAT & SCREEN BY OTHERS 8 3 8'-2 4 5 6'-4 8 ROOF CURB BY OTHERS 8 5 37'-8 8 3 THIMBLE BY OTHERS 3016 BOTTOM OF OD ROOF DECK 5 32'-8 8 7 22'-1 8 UNINSULATED STACK NOTE: THE ENTIRE UNLINED STACK 3 34 MAX OD IS PAINTED TEMPERKOTE 850 16 HIGH TEMP SILVER 5 27'-8 8 AIR BREAK 5 22'-8 8 3 20'-8 4 35'-10 3 15'-8 4 AFTERBURNER CONTROL/EXCESS TEMP THERMOCOUPLE 3 3 20'-8 10'-84 4 INSULATED AFTERBURNER DRAWING SUBMITTED FOR APPROVAL 3 APPROVED AS SUBMITTED 5'-8 4 APPROVED WITH CHANGES RE-SUBMIT FOR REFERENCE ONLY SIGNATURE DATE 0 3 3 62 62 16 16 A0 06/10/25 KJS FOR APPROVAL No. DATE BY DESCRIPTION REVISION UNINSULATED STACK G.A. TITLE NOTICE: THIS PRINT IS OUR SC UNISULATED STACK GENERAL ARRANGEMENT PROPERTY AND SUBJECT TO 3/8" = 1' - 0" APPROX. 7,500 LBS. RETURN UPON DEMAND. ALL DRN RIGHTS OF DESIGN AND (1 REQ'D.) . INVENTION ARE RESERVED. KJS 06/10/25 SHEET DWG No REV TRU-HEAT BURNOUT FURNACE - 7 X 8 X 4 1 15660 LASALLE ST SOUTH HOLLAND IL 60473 CUST 1 17968GA2 A0 (708) 339-6810 www.armilcfs.com BLUE CASTINGS (ARLINGTON, WA) SHEET 1 OF 1 , 17968GA2 - Uninsulated Stack General Arrangement, 6/10/2025 4:08:33 PM INSTALLATION REQUIREMENTS: Arlington, WA LOCATION: OXYGEN PROBE (130 FT. ABOVE SEA LEVEL) (SSI GOLD PROBE) NATURAL GAS FUEL: (1,000 BTU/CUBIC FOOT) 4,490 SCFH @ 2 PSIG AFTERBURNER BURNER 1,551 SCFM DILUTION AIR, MAKE-UP AIR: BURNERS IN REAR 1,034 SCFM COMBUSTION AIR 6.5 FLA @ 460 VAC, 3 PH, 60 HZ ELECTRICITY: 2" NPT GAS CONNECTION 65 kA SCCR PNEUMATIC AIR: 15 SCFM @ 80 PSI MIN. ELECTRICAL PANEL FURNACE = 23,000 LBS. 3 EST. SHIPPING WEIGHTS: AFTERBURNER = 7,000 LBS. 1 178 TOTAL = 29,100 LBS. 36 2 PAINT COLOR: PROCESS BLUE FURNACE SPECIFICATIONS: OPERATING CONTROL / EXCESS 450F - 2,200F 11 TEMPERATURE: TEMP. THERMOCOUPLE DOOR LIFTING / APPROX. 1 FT/SEC LOWERING SPEEDS 12 1 1 APPROX. 1842 15'-42 13 DRAWING SUBMITTED FOR APPROVAL 1 APPROVED AS SUBMITTED 1 107 84 60 4 APPROVED WITH CHANGES 16 RE-SUBMIT FOR REFERENCE ONLY DOOR OPEN SIGNATURE ROOF PENETRATION 9 & CLOSE BUTTONS DATE T.B.D. DOOR SWING ROOF PENETRATION 12 3/4 NPT PNUEMATIC TO BE DETERMINED CONNECTION 17 17 13 9 13 12 72 12 10" COMBUSTION AIR INLET STACK LIGHT AFTERBURNER 96 1 12'-9 SHIPPING LENGTH (OPENING WIDTH) COMBUSTION 4 SECTION A-A AIR BLOWER 49 SCALE 1 : 24 THERMOCOUPLE CONTROL/EXCESS TEMP THERMOCOUPLE (OPPOSITE SIDE) 1 1 APPROX. 618 *APPROX. 1.5 SEC 21 618 COMBUSTION PIPING RESIDENCE TIME *APPROX. 1.5 SECRESIDENCE TIME FURNACE DOOR AIR BLOWER ALLOWANCE PIPING IN "UP" POSITION ALLOWANCE SPLIT 3 4 LINE 1 60 X 72 X 38 SPLIT LINE 20'-82 WORK ZONE 20'-8 12 193 ROOF HT. T.B.D. 12 8 1 1 PNEUMATIC DOOR 114 9'-6 4 4 CYLINDER (SHIPPING 181.88 HEIGHT) DOOR ROOF HT. T.B.D. 15'-2 APPROX. OPEN/CLOSE 5 5 BUTTON 128 10'-8 8 8 1 1 38 102 8'-6 60** 4 4 SHIPPING HEIGHT OPENING) (FULL DOORA A 1 2 5'-9 9'-6 49 1 30 4 (PASS HT.) 6 PNEUMATIC DOOR 12 72 REF. 12 SAFETY LOCKS 6 4 TRAY HT. A0 05/21/25 KJS APPROVAL REQUEST 1387 11'-67 11'-8 SHIPPING WIDTH 96 OPENING WIDTH No. DATE BY DESCRIPTION 8 8 *RESIDENCE TIME SUGGESTED ELECTRONIC 3 6 PIER HT. REVISION ** NOTE: DOOR MAY ALSO 124 TITLE NOTICE: THIS PRINT IS OUR SC *RESIDENCE TIME SUGGESTED FOR PMMA BURNOUT. CHART BE OPENED TO ONLY 48" 8 FURNACE GENERAL ARRANGEMENT PROPERTY AND SUBJECT TO 3/4" = 1' - 0" RETURN UPON DEMAND. ALL FOR PMMA BURNOUT. RECORDER RIGHTS OF DESIGN AND DRNKJS 05/21/25 INVENTION ARE RESERVED. FURNACE GENERAL ARRANGEMENT SHEET DWG No REV TRU-HEAT BURNOUT FURNACE - 7 X 8 X 4 1 (1 REQ'D.) 15660 LASALLE ST SOUTH HOLLAND IL 60473 CUST 17968GA1 A0 (708) 339-6810 www.armilcfs.com BLUE CASTINGS (ARLINGTON, WA) 1 SHEET 1 OF 1 , 17968AGA1 - Furnace General Arrangement, 5/21/2025 2:02:48 PM NOTE STARTED WITH 16138 SEACAST STRETCHED WIDTH OF FCE BY 12" INCREASED iD OF AFTER BURNER FROM 32" TO 35" 5300 DENVER AVENUE SOUTH SEATTLE, WASHINGTON 98108 (206) 787-8500 6 5 4.7 4.5 4 3.8 3.5 3.2 3 2.3 2 1 THE PLANS AND SPECIFICATIONS HEREIN ARE OWNED BY AND FOR THE SOLE USE OF ACCO ENGINEERED SYSTEMS, INC. (“ACCO”), AND MAY NOT BE REPRODUCED OR USED BY OTHERS FOR ANY PURPOSE UNLESS AUTHORIZED BY ACCO IN WRITING. ACCO CANNOT ACCEPT ANY LIABILITY, WARRANTY, OR 340'-0" OVERALL OBLIGATION IN THE EVENT OF UNAUTHORIZED USE. 340'-0" OVERALL 40'-0" 14'-0" 22'-0" 25'-0" 7'-0" 30'-0" 18'-0" 6'-0" 40'-0" 12'-0" 36'-0" 7'-0" COTROL PANEL COTROL PANEL 5 PSI GAS METER 26,685 CFH 2" NG UP 4,560 CFH 2 1/2" NG 14" WC 22,125 CFH POWER TRANS EMERGENCY GENERATOR 1" CDA GR GAS 4 1 WATER CONNECTIONS WATER CONNECTIONS CDA BLOW DOWN A CDA CDA CDA 1 1 ET 1" ICW DN FOR 1 4" SW DN TO FLOOR WH-3 2" SW UP TO LV 4" LW DN TO 3" LW DN 3 HUB DRAIN FOR (1 FU) FLOOR HUB FLOOR HUB WH 1 1/4" ICW DN FIRE SPRINKLER DRAIN (8 FU) DRAIN (6 FU) SMOKE HOG 3 FOR HVAC BLOWDOWN (MAX: CDA DROP TO 16 FT AFF. MAKE UP EYEWASH 100 GPM) 2" LVTR LOCATE 9 FT FROM COLUMN A-4 3" LW CO TABLE TABLE 3/4" INDUSTRIAL WATERTABLE 4" SW CO 2" SV WATER DUST COLLECTOR DROP TO 10' AFF, VALVE 2" LVTR 4" LW CO (BY VATECH) AND CAP 3" DCW UP 3/4" INDUSTRIAL WATER LAV-1 2" LVTR BFP BFP TP-1 3/4" ICW DROP VALVE AND CAP TO CDA 3" LW CO FEED WATER SOFTENER 1" ICW 3/4" INDUSTRIAL 1 2 WATER DROP TO 10' FD-1 (2)2" SV UP CDA AFF, VALVE AND CAP PATTERN ASSEMBLY 4" SW UP TO WC ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW ICW WC-2 (4 FU) 3" LW DN TO TP-1 1 1/2" ICW 4" SW UP TO WCO 3" LW DN TO FLOOR HUB FLOOR HUB 1/2" DCW 1/2" TP UP 3/4" INDUSTRIAL 1 1/2" ICW 1 1/2" ICW CDA BLOW DOWN 1 1/2" ICW DRAIN (6 FU) DRAIN (6 FU) WATER DROP FOR TP WH CP ET 2 1 WH 3" LW CO TO 10' AFF 2" LVTR 1 1 1 P3.02 1 1/2" INDUSTRIAL A 3/4" ICW MS-1 3/4" COND TO MS WATER TO BFP-2 143863 2 SHEET NOTES: 2 1/2" NG 5 PSI 2" SVTR WC-2 WC-2 (2)2" SW UP 22,000 CFH 2 CDA BLOW DOWN (2)1/2" TP UP TO FD (4 FU) 1 CA DROP DOWN TO 10' AFF. NG TP-1 VALVE AND CAP FD-1 WC-1 FD-1 4" SW UP B ICW CART UR-1 2" SV UP 2 CA DROP FOR FUTURE. TEE ICW SHELL 1" ICW BOILERCLAVE CDA 1" CDA VALVE AND CAP LOCATED ICW VALVE AND CAP AT MAIN 2" SW UP TO 1 FT NORTH OF GRID B CDA INPUT LV (2 FU) LAV-1 1" DHW CDA LAV-1 DROP TO 10' AFF 1" CDA AREA OF WORK 1 1/4" DHW ICW VALVE AND CAP 2 1/2" 5 PSI NG 1" CDA KEYPLAN 1750 CFH 3" LW UP TO 1" CDA FLOOR HUB 4" SW CO DRAIN (6 FU) PATTERN SETTER 2" DCW 3/4" HWR 3" LW CO 2 B 2 NG TABLE 2" LVTR 3" CDA 3/4" INDUSTRIAL 1 1/2" CDA 3/4" HWR ICW 1" CDA WATER DROP TO 10' CDA BLOW DOWN ICW DEWAX FURNACE AFF, VALVE AND CAP 1" 5 PSI NG 1" 5 PSI NG CDA CDA CDA CDA CDA CDA CDA 2000 CFH VALVE AND CAP DROP 1" 5 PSI NG CDA FOR FUTURE USE VALVE AND CAP DROP 1000 CFH 1" 5 PSI NG FOR FUTURE USE 1" CDA 1" CDA ICW CDA 3" LW CO 1000 CFH 2 1/2" 5 PSI NG CDA 20,000 CFH NG NG NG NG NG NG NG LOAD &NG 3/4" INDUSTRIAL UNLOAD 1" INDUSTRIAL SLURRY PREPARATION 2 WATER DROP WH 1 WATER DROP TO 10' NG AFF, VALVE AND CAP 4" LW CO TO 10' AFF 5 P3.02 WH-5 FOR 4" LW CO CDA ICW UTILITY SINK 1 1 1 RINSE CDA BLOW DOWN 3" LW UP TO 1 FLOOR HUB 2" LVTR 2" LW UP SK (2 FU) DRAIN (6 FU) ICW 2" LVTR 3" LW UP TO ETCH FLOOR HUB 1 1/2" ICW CDA 1" CDA DRAIN (6 FU) 3/4" COND TO CDA HUB DRAIN TYP 2 1 1" CDA NG 2 1/2" 5 PSI NG KIT AREA VALVE AND CAP DROP TABLE CDA FOR FUTURE USE ICW 1 1/2" CDA 1 20,000 CFH 2" CDA CDA BLOW DOWN NG 1 C CDA CDA 2" LVTR 1" NG 14" WC 1 ICW DROP FOR UH-4 AT GRID 7 C 125 CFH PRE PRE CDA APPROX 8' 5" STAIRS MOVED 2 1/2" 5 PSI NG HEAT 2 HEAT 1 VALVE AND CAP FOR FUTURE USE 3" CDA 2"LV CDA F 4/7/2021 RECORD DRAWINGS AS ICW E 11/18/2020 100% CD AS D 11/13/2020 50% CD AS CDA BLOW DOWN x x x C 10/20/2020 100% DD AS x x LV ICW B 09/30/2020 PERMIT SET AS BACKTILTFURNACE REMOTE BOX 200D 201POT FURNACE TILT FPI REST FPI DEVELOPER MOLD LIFT LAV-1 TC LANCE 3/4" ICW (3)2" SW UP A 08/31/2020 50% DD AS HOIST x CDA FPI INSPECTION FD-1 BACKTILTFURNACE REMOTE BOX 200D 201POT LAV-1 FURNACE TO (6)LV TILT x VALVE AND FURNACE PROFILE FURNACE DRIVE CHARGER RAM RETRACTED DISABLETEACH 2 FURNACE PROFILE FURNACE DRIVE ENABLEEXECUTETC LANCE UP No. Date Description By CHARGER HOIST UP REMOTE BOX 200A CAP ABOVE (6 FU) LAV-1 x x x UR-1 UR-1 WC-1 WC-1 WC-2 Revisions OXYGEN PROBE DRAIN 2" SW UP LV (SSI GOLD PROBE) AFTERBURNER BURNER 4" LW UP TO FPI REST TO DF BURNERS IN REAR FLOOR HUB WALK IN BLAST 2" NPT GAS CONNECTION DRAIN (6 FU) DF-1 Project ELECTRICAL PANEL CDA 3 17 3612 8 CL 2" VTR LAV-1 LAV-1 WC-1 WC-1 WC-1 WC-2 232'-0" OVERALL ICW 4" LW CO 2 LAV-1 LV CASTING OPERATIONS CONTROL / EXCESS LAV-1 TEMP. THERMOCOUPLE FPI DRIER TP-1 FD-1 1 1 APPROX. 2 15'-42 13 ICW 1 2 LV 107 CDA 4 FPI EMULSIFIER 2" SW UP TO 1 1/2" CDA 6108 188TH STREET NE SK (2 FU) CDA SK-1 DOOR OPEN & CLOSE BUTTONS 2 ARLINGTON, WA 98223 DOOR SWING 4" SW DN 3/4 NPT PNUEMATIC 1" ICW VALVE CONNECTION AND CAP 1" ICW VALVE CDA CDA LV TO CO FPI AND CAP FOR 1" CDA 10" COMBUSTION 1" ICW FUTURE AIR INLET LC STACK LIGHT 1 12'-9 SHIPPING LENGTH COMBUSTION 4 Title AIR BLOWER ICW LV CDA 3/4" INDUSTRIAL 4" LW CO FPI RINSE WATER DROP 1 1/2" ICW VALVE 4" LW UP TO 2 FIRST FLOOR FOR PROCESS 2 TO 10' AFF FLOOR HUB PLUMBING PLAN WATER SYSTEMS DRAIN (8 FU) ICW LV SEE P2.01A FOR CONTINUATION FPI REST SEE P2.01A FOR CONTINUATION D NORTH SEE P2.01B FOR CONTINUATION CDA SEE P2.01B FOR CONTINUATION 2" LV X:\942190_CASTING OPERATIONS\004-E-PL\DWG\Presentation\942190_P2_01A 1" ICW CDA CDA 3" LW CO A.STIENS D.SHEARER Designed By Checked By A.STIENS R.FENTON Drawn By Project Manager FIRST FLOOR PLUMBING PLAN - NORTH 942190 Andrew Stiens 1 N SCALE: 1/8" = 1'-0" Job Number AS SHOWN P2.01A Scale 2021-04-07 03:59 PM PRE-ENGR JOIST MFR SHALL DESIGN TOP CHORD OF PRE-ENGR OMIT L 3 x 3 IF EDGE DIST JOIST FOR AXIAL SEISMIC FORCE LESS THAN 1'-0" SHOWN ON THE ROOF FRAMING DECK PENETRATION PLAN TO BE TRANSFERRED THRU 16" DIA (OR 16"x16") THE BEARING SEAT AND ACROSS OR LESS STEEL JOIST ATTACH METAL DECK TO STEEL JOIST THE JOIST GIRDER ALL EDGES OF FRAME PER SCHEDULE L 5 x 5 x 5 16 L 5 x 5 x 5 16 JOIST PRE-ENGR JOIST PER PLAN TO GIRDER 1/4 4 TYPICAL L 3 x 3 x 1 4 EA SIDE OF PENETRATION TACOMA SEATTLE SPOKANE TRI-CITIES 2215 North 30th Street, Suite 300, Tacoma, WA 98403 L 2 x 2 x 14 x 0'-4" 253.383.2422TEL 253.383.2572 FAX www.ahbl.comWEB AT CORNER EXTEND 2'-0" BEYOND PENE EA SIDE CASTING OPERATIONS 8'-0" MAX 188th St. Business Park ATTACH USING TYP DECK ATTACHMENT METHOD AT EA MECH UNIT - DECK VALLEY - TYP BEAR ONE SIDE ON JOIST CL DECK SUPPORTS PRE-ENGR JOIST FOR OPENINGS 16" DIA (OR 16"x16") GIRDER PER PLAN L 5 x 5 x 5 16 OR LESS IN METAL ROOF DECK CUT DUCT PENETRATIONS THROUGH BRACE WHERE REQ'D BY DECK. NO ADDITIONAL SUPPORTS TYP 14800 NE NORTH WOODINVILLE WAY PRE-ENGR JOIST MFR, TYP REQUIRED 3/16 WOODINVILLE, WA AT CONTRACTOR'S OPTION: COPE ONE LEG AND BEND AS JST CONNECTION TO GIRDER STEEL JOIST OMIT COPED LEG AND BUTT SHOWN - TYP STEEL JOIST IS PART OF SFRS WELD L 4 x 4 TO L 5 x 5 2" 3/16 L 4 x 4 x 1 4 L 5 x 5 x 5 SECTION 16 2200333.20 1 MECHANICAL UNIT TYPICAL FRAMING SUPPORT 1" = 1'-0" 1 MEMBER 4" COPE DECK ATTACHMENT IS PART OF SFRS BOTTOM PERMIT SUBMITTAL LEG TYP MECH UNIT SUPPORT TOP OF PARAPET PER JUNE 24, 2020 ARCH 4 1" = 1'-0" ATTACH AND SPLICE LEDGER PER 3 S4.1 4'-0" MAX ROOF JST PER PLAN HSS 5x5x3/8" 1'-4" 1'-0" 1'-0" DECK PENETRATION ELEV PER ARCH 2" 10" 3/16 2" NOTICE: L 4 x 4 x 14 ALTERATION OF THIS DOCUMENT SHALL INVALIDATE THE PROFESSIONAL SEAL AND SIGNATURE. PUBLICATION OF THIS 5 C15 x 33.90, SPLICE DOCUMENT DOES NOT DEROGATE FROM RESERVED OWNERSHIP L 5 x 5 x 16 TYP RIGHTS IN IT. THIS DOCUMENT IS FOR USE ONLY FOR THE PROJECT PER 3 IDENTIFIED IN THE TITLE BLOCK AND IS NOT TO BE USED FOR EMB PL 3/4" x 12"x 12" 3/16 1 REPAIR, REMODEL OR ADDITION TO THAT PROJECT OR FOR ANY ATTACH METAL DECK TO 22" 3/16 S4.3 OTHER PROJECT. W/ (4) 5/8"DIA x 5" HSS ALL EDGES OF FRAME WHS AT 8" GA TO ADD C15 EQ SPACE AT PER SCHEDULE 5/16 9 EMBED 8'-0"OC MAX FOR OPENINGS GREATER THAN 16" DIA SUPPORT END PL 3/8"x4"x1'-3" W/ (2) 1 MEMBER 5/8" DIA EXP ANCHORS 4" (OR 16"x16") IN METAL ROOF DECK EMBED 5" KNIFE PL CONNECTION IS TYPICAL ROOF JOIST BEARING COPE PART OF SFRS WITHIN 18" OF PANEL EDGE DECK ATTACHMENT IS PART OF SFRS BOTTOM LEG SECTION TYP OPENING IN METAL ROOF DECK SECTION 2 3 5 1" = 1'-0" 1" = 1'-0" 1" = 1'-0" PANEL JOINT LOC VARIES 5 3/16 3 1/4 4 LEDGER PER S4.1 1 5/16 GIRDER BLKG PERS4.1 TOP OF PARAPET PER 3/16 5/16 12 ADD PL 3/8"x2"x1'-0" FOR DECK ARCH 1 1 1 SUPPORT 2"12"12" 3 1 1/4 3 TYP END WALL EMBED ROOF JST PER PLAN SPLICE PL 4 x 2 2 x 1'-8" 50KSI LOCATE AT TOP OF 4 W27 PER PLAN AT SIM BEVEL BACK EDGE TO FIT SNUG GIRDER (LOWER THANS4.1 5/16 6 TO ANGLE FACE REST) PRE-ENG JOIST SPLICE PL 3/8"x6"x0'-6" GIRDER PLAN 3" 1'-0" 1'-0" 1/4 3" L3x3x1/4"x0'3" W/ 3" PL 1/2"x6x0'-11" W/ ROOF FRAMING 1/2" DIA EXP END PL 3/8"x5"x0'-7" 3" ANCHOR, EMBED 4" HSS5x5x1/4"x0'-11 1/2" MIN. SPACE AT AT CENTER AND (2) 5/8" DETAILS 3"" 24"OC ALONG W27 DIA EXP ANCHORS 1'-01" 1" 112 EMBED 5" AT 8" GAGE 4 4" (2) PL 3/8"x4"x0-'6" 3 (6) 4" DIA A325-N BOLTS JST BEARING AT SIM, ONE TOP AND BTM 6" HSS ADD EMBEDS AND PL'S TO HSS PER 2 EMBED KNIFE PL 1/2" LAH CLR DLB - 5/16 TYP DO NOT WELD JOIST BOTTOM CHORD ALL PL'S AND WELDS ARE HSS COL PER FDN STRAP CONNECTION TO TO STABILIZER PL PART OF SFRS PLAN WALL IS PART OF SFRS STABILIZER PL 3/4"x6x0'-7" NOTCH HSS AT CL SECTION SECTION SECTION 1/4 6 7 8 S4.2 1" = 1'-0" 1" = 1'-0" 1" = 1'-0" 13 18 DATE: June 22, 2020 FILENAME: Q:\2020\2200333\20_STR\CAD\2200333S-40.dwg Q:\2020\2200333\20_STR\CAD\2200333S-40.dwg, 6/22/2020 9:30:14 AM, LHIGGINS, DWG To PDF.pc3 Permit #: 6717 Permit Date: 09/17/25 Permit Type: COMMERCIAL MECHANICAL Project Name: Arlington Amril Furnace venting install Applicant Name: Five Star Mechanical Applicant Address: 7509 Grange ST West Applicant, City, State, Zip: Lakewood, WA 98499 Contact: John Ware Phone: 206-786-8278 Email: johnw@fivestarmech.com Scope of Work: Install factory made venting on a furnace Valuation: 104000.00 Square Feet: 79000 Number of Stories: 1 Construction Type: llA Occupancy Group: B; Business ID Code: Permit Issued: 10/24/2025 Permit Expires: 04/29/2026 Form Permit Type: COMMERCIAL MECHANICAL Status: COMPLETE Assigned To: Hannah Hardwick Property Parcel # Address Legal Description Owner Name Owner Phone Zoning Section 22 Township 31 Range 05 Quarter NE PAR C CITY ARL BLA FILE NO CASTING 250 BUSINESS / 31052200101000 18410 63RD AVE NE PLN-587 REC AFN OPERATIONS LLC PROFESSIONAL 201909245004 BEING PTN NW1/4 NE1/4 SD SEC Contractors Contractor Primary Contact Phone Address Contractor Type License License # 7509 Grange St. CONSTRUCTION Five Star Mechanical John Ware 206-786-8278 UBI 601 937 083 West CONTRACTOR 7509 Grange St. CONSTRUCTION Labor and Five Star Mechanical John Ware 206-786-8278 FIVESM*010JT West CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status C08. GAS PIPING 10/28/2025 AM requested 10/29/2025 10/29/2025 BUILDING Approved ROUGH-IN Plan Reviews Date Review Type Description Assigned To Review Status COMMERCIAL 09/17/2025 BUILDING Approved MECHANICAL Fees Fee Description Notes Amount Enter 1 if permit is for commercial Web Only - Mechanical Commercial Plan mechanical $995.40 Review (Table 4-1) Credit Card Service $29.86 Processing/Technology $25.00 Ductwork/Dryer Duct $25.00 Gas Piping/Units Enter # of units $15.00 Credit Card Service $1.95 Total $1,092.21 Attached Letters Date Letter Description 10/23/2025 Building Permit 10/10/2025 Building Permit 09/17/2025 Web Form - Building Application Payments Date Paid By Description Payment Type Accepted By Amount 09/17/2025 John Ware 24259176 $29.86 XBP Conf: 09/17/2025 $995.40 243259176 10/10/2025 J Ware cc LaNay Hendrick $1.95 XBP Conf: 10/10/2025 $65.00 245512452 Outstanding Balance $0.00 Notes Date Note Created By: 03/02/2026 sent expiration notice Hannah Hardwick Uploaded Files Date File Name 10/24/2025 29033839-20250917_BLD6717_Approved Venting Drawing2.pdf 10/24/2025 29033840-20250917_BLD6717_ApprovedStructural Drawing.pdf 10/24/2025 29033841-20250917_BLD6717_ApprovedGas Piping.pdf 10/24/2025 29033842-20250917_BLD6717_Approved Venting Drawing.pdf 10/24/2025 29033843-20250917_BLD6717_Approved Vent.pdf 10/24/2025 29033784-2025_BLD6717_Issued Permit.pdf 09/17/2025 6e1d6c4d08d7ffc10a2b6e02707cfc78_gas_pipe_drawing.pdf 09/17/2025 1f14cb0b5d61ea86cde109908327ab9a_s4.2_-_structural_openings_details.pdf 09/17/2025 4fbef211b12c48f05129b61b2f9d508b_stack_venting_drawing.pdf 09/17/2025 d3708cf2b795de2d46cc84aa41bb37bb_20814771-commercial_mechanical_-_permit_application.pdf 09/17/2025 d5361d74163589bee7c2e5e7d54789a1_furnace_drawing.pdf 09/17/2025 4fbef211b12c48f05129b61b2f9d508b_stack_venting_drawing.pdf