Loading...
HomeMy WebLinkAbout17324 SMOKEY POINT DR_BLD964_2026 ✔ 17324 Smokey Point Dr A/C Condenser Replacement 2900 Nick Damianidis 4253288206 17324 Smokey Point Dr Arlington WA 98223 nickrivers@comcast.net Robert 4253594819 22029 161st ave se Monroe WA 98272 robert_ets@hotmail.com ETS 4253594819 22029 161st ave se Monroe WA 98272 robert_ets@hotmail.com 8/14/17 Energts025ph 1 04/07/2016 Robert Charles Rose 25HCE4 Comfort™ 14 Heat Pump with Puronr Refrigerant 1---1/2 to 5 Nominal Tons Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 14 SEER / 11.5 -- 11.7 EER / 8.2 HSPF S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound S Sound level as low as 69 dBA S Sound levels as low as 68 dBA with accessory sound blanket Comfort S System supports CôRt, Edger or standard thermostat controls Reliability S Puronr refrigerant -- environmentally sound, won’t deplete the ozone layer and low lifetime service cost. S Scroll compressor S Internal pressure relief valve S Internal thermal overload S High pressure switch S Loss of charge switch S Filter drier S Balanced refrigeration system for maximum reliability Durability Carrier heat pumps with Puronr refrigerant provide a collection of WeatherArmort protection package: features unmatched by any other family of equipment. The 25HCE4 has been designed utilizing Carrier’s Puron refrigerant. S Solid, durable sheet metal construction The environmentally sound refrigerant allows consumers to make a S Dense wire coil guard responsible decision in the protection of the earth’s ozone layer. S Baked--on powder paint NOTE: Ratings contained in this document are subject to Applications change at any time. Always refer to the AHRI directory S Long--line -- up to 250 feet (76.20 m) total equivalent length, up (www.ahridirectory.org) for the most up--to--date ratings information. to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.38 m) evaporator above condenser (See Longline Guide for more information.) S Low ambient (down to --20_F/--28.9_C) with accessory kit MODEL NUMBER NOMENCLATURE 1 2 34 5 6 7 8 910 1112 13 N N A A A/N N N N A/N A/N A/N N N 25 H C E 4 3 6 A 0 0 3 0 Product Product Major Cooling Grille Minor Tier SEER Open Open Voltage Series Family Series Capacity Variations Series 0=Not 0=Not 25 =HP H =RES HP C=Comfort E =Puron 4=14 SEER A=Dense Grille 3=208/230---1 0, 1, 2... Defined Defined Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program For verification of certification for individual products, go to www.ahridirectory.org. STANDARD FEATURES Feature 18 24 30 36 42 48 60 Puron Refrigerant X X X X X X X Scroll Compressor X X X X X X X FieldInstalledFilter Drier X X X X X X X Front Seating Service Valves X X X X X X X Internal Pressure Relief Valve X X X X X X X Internal Thermal Overload X X X X X X X Long Line capability X X X X X X X Low Ambient capability with Kit X X X X X X X Suction Line Accumulator X X X X X X X High Pressure Switch X X X X X X X Loss of Charge Switch X X X X X X X X= Standard 2 PHYSICAL DATA UNIT SIZE SERIES 18---30 24---30 30---30 36---31 42---30 48---30 60---30 Compressor Type Scroll REFRIGERANT Puron (R---410A) Control TXV (Puron Hard Shutoff) Outdoor Heating Piston # 42 46 49 57 61 65 73 Charge lb (kg) 5.3 (2.4) 5.6 (2.5) 6.4 (2.9) 7.67 (3.48) 8.25 (3.74) 8.68 (3.94) 10.6 (4.81) COND FAN Forwrard Swept or Propeller Type, Direct Drive Air Discharge Vertical Motor HP 1/12 1/10 1/4 1/5 1/4 1/4 1/4 Motor RPM 1100 1100 1100 1100 1100 1100 800 VALVE CONNECT.(In.ID) Vapor 5/8 5/8 3/4 3/4 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES* (In. OD) Rated Vapor 5/8 5/8 3/4 3/4 7/8 7/8 1---1/8 Max Liquid Line 3/8 *Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. Note: See unit Installation Instruction for proper installation. VAPOR LINE SIZING AND COOLING CAPACITY LOSS Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for HP systems with Puron refrigerant: Vapor Line Sizing and Cooling Capacity Losses -- Puronr Refrigerant 1-- Stage Heat Pump Applications Cooling Capacity Loss (%) Acceptable Total Equivalent Line Length (ft) Unit Nominal Size Vapor Line Standard Application Long Line Application Requries Accessories (Btuh) Diameters (In. OD) 25 50 80 80+ 100 125 150 175 200 225 250 (7.62) (15.2) (24.4) (24.4+) (30.48) (38.10) (45.72) (53.34) (60.96) (68.58) (76.20) 18000 1/2 1 2 3 3 4 6 7 8 9 10 12 1---Stage HP 5/8 0 0 1 1 1 1 2 2 3 3 3 24000 5/8 0 1 1 1 2 3 3 4 4 5 6 1---Stage HP 3/4 0 0 0 0 0 1 1 1 1 1 2 5/8 1 2 3 3 3 4 5 6 7 8 9 30000 3/4 0 0 1 1 1 1 2 2 2 3 3 1---Stage HP 7/8 0 0 0 0 0 1 1 1 1 1 1 5/8 1 2 4 4 5 6 7 9 10 11 13 36000 3/4 0 0 1 1 1 2 2 3 3 4 4 1---Stage HP 7/8 0 0 0 0 0 1 1 1 1 2 2 42000 3/4 0 1 2 2 2 3 4 4 5 6 6 1---Stage HP 7/8 0 0 1 1 1 1 2 2 2 3 3 48000 3/4 0 1 2 2 3 4 5 5 6 7 8 1---Stage HP 7/8 0 0 1 1 1 2 2 2 3 3 4 3/4 1 2 4 4 5 6 7 9 10 11 12 60000 7/8 0 1 2 2 2 3 4 4 5 5 6 1---Stage Puron HP 11/8 0 0 0 0 1 1 1 1 1 1 2 Standard Length = 80 ft. (24.4 m) or less total equivalent length Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Applica- tion Guidelines 3 REFRIGERANT PIPING LENGTH LIMITATIONS Maximum Line Lengths: The maximum allowable total equivalent length for heat pumps varies depending on the vertical separation. See the tables below for allowable lengths depending on whether the outdoor unit is on the same level, above or below the outdoor unit. Maximum Line Lengths for Heat Pump Applications MAXIMUM ACTUAL LENGTH MAXIMUM EQUIVALENT LENGTH{ MAXIMUM VERTICAL ft (m) ft (m) SEPARATION ft (m) Units on equal level 200 (61) 250 (76.2) N/A Outdoor unit ABOVE 200 (61) 250 (76.2) 200 (61) indoor unit Outdoor unit BELOW See Table ’Maximum Total Equivalent Length: Outdoor Unit BELOW Indoor Unit’ indoor unit { Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. Maximum Total Equivalent Length{ -- Outdoor Unit BELOW Indoor Unit HP with Puronr Refrigerant --- Maximum Total Equivalent Length{ Liquid Line Vertical Separation ft (m) Outdoor unit BELOW indoor unit; Size Diameter w/ TXV 0---20 21---30 31---40 41---50 51---60 61---70 71---80 (0 --- 6.1) (6.4 --- 9.1) (9.4 --- 12.2) (12.5 --- 15.2) (15.5 --- 18.3) (18.6 --- 21.3) (21.6 --- 24.4) 18000 HP with 3/8 250* 250* 250* 250* 250* 250* 250* Puron 24000 HP with 3/8 250* 250* 250* 250* 250* 250* 250* Puron 30000 HP with 3/8 250* 250* 250* 250* 250* 250* 250* Puron 36000 HP with 3/8 250* 250* 250* 250* 250* 250* 250* Puron 42000 HP with 3/8 250* 250* 250* 250* 250* 250* 150 Puron 48000 HP with 3/8 250* 250* 250* 250* 230 160 --- --- Puron 60000 HP with 3/8 250* 225* 190 150 110 --- --- --- --- Puron * Maximum actual length not to exceed 200 ft (61 m) { Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. --- --- = outside acceptable range LONG LINE APPLICATIONS An application is considered Long Line when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units. For Heat Pump systems, the chart below shows when an application is considered Long Line. Beyond these lengths, long line accessories are required: HP WITH PURONr REFRIGERANT LONG LINE DESCRIPTION ft (m) Beyond these lengths, long line accessories are required Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor 3/8 80 (24.4) 20 (6.1) vertical or 80 (24.4) total 80 (24.4) Note: SeeLong LineGuideline for details 4 ACCESSORIES ORDER NUMBER DESCRIPTION 18---30 24---30 30---30 36---30 42---30 48---30 60---30 HC32GE234 BALL BEARING FAN MOTOR X HC34GE240 BALL BEARING FAN MOTOR X HC38GE219 BALL BEARING FAN MOTOR X HC40GE226 BALL BEARING FAN MOTOR X X X HC40GE228 BALL BEARING FAN MOTOR X KAACH1601AAA CRKC HTR KIT X X KAACH1701AAA CRKC HTR KIT X X X X KAACS0201PTC KIT PTC X X X X X X X KAAFT0101AAA FRZ THERM KIT X X X X X X X KAATD0101TDR TIME DELAY KIT X X X X X X X KHAIR0201AAA ISLN RELAY KIT X X X X X X X KHALS0401LLS SOL VALVE KIT X X X X X X X KHAOT0201SEC OUTDR THERM KIT X X X X X X X KHAOT0301FST OUTDR THERM KIT X X X X X X X KHASS0606MPK SNOW STAND KIT X X X X X X X KSACY0101AAA CYCLE PROTR KIT X X X X X X X KSAHS1701AAA HARD START KIT X X X X X X X KSALA0301410 LOW AMBIENT KIT X X X X X X X KSALA0601AAA MOTORMASTER KIT X X X X X X X KSASF0101AAA SPRT FEET KIT X X X X X KSASF0201AAA SPRT FEET KIT X X KSASH0601COP SOUND BLKT KIT X X X X X KSASH2101COP SOUND BLKT KIT X X KSATX0201PUR TXV KIT (for copper coils) X X X KSATX0301PUR TXV KIT (for copper coils) X X KSATX0501PUR TXV KIT (for copper coils) X X KSBTX0201PUR TXV KIT (for aluminum coils) X X X KSBTX0301PUR TXV KIT (for aluminum coils) X X KSBTX0401PUR TXV KIT (for aluminum coils) X X x = Accessory ACCESSORY THERMOSTATS Capabilities Heat Cooling Part Number Description Gas Electric Heat Pump Stages Stages TP---WEM01 CôR™, Wi---Fi Programmable Relative Humidity Thermostat X X X 4 2 TP---PRH01---A edge™ Programmable Relative Humidity Thermostat X X X 3 2 TP---PHP01 edge™ Programmable Thermostat (HP or AC) X X 3 2 TP---NRH01 edge™ Non---Programmable Relative Humidity Thermostat X X X 3 2 TP---NHP01 edge™ Non---Programmable Thermostat (HP or AC) X X 3 2 TC---WHS01 Wi---Fi® Programmable X X X 3 2 TC---PHP01 Programmable Thermostat (HP or AC) X X 3 2 TC---NHP01 Non---Programmable Thermostat (HP or AC) X X 3 2 TB---PHP01 Programmable Thermostat (HP or AC) X X 2 1 TB---NHP01 Non---Programmable Thermostat (HP or AC) X X 2 1 Thermostat Accessories Part Number Description Used With TP---EXP EXP Card for Programmable Thermostats TP---Pxx TSTATXXCNV10 Thermostat Conversion Kit (4 to 5 wire) 10 pack All Carrier branded thermostats TX---LBP01 LargeDecorativeBackplate TP---Pxx, TP---Nxx, TC---Pxx TX---MBP01 Medium Decorative Backplate TC---Nxx, TB---Pxx TX---SBP01 Small Decorative Backplate TB---Nxx 5 ACCESSORY USAGE GUIDELINE REQUIRED FOR LOW---AMBIENT REQUIRED FOR REQUIRED FOR Accessory COOLING APPLICATIONS SEA COAST APPLICATIONS LONG LINE APPLICATIONS* (Below 55F / 12.8C) (Within 2 miles / 3.22 km) Accumulator Standard Standard Standard Ball Bearing Fan Motor Yes{ No No Compressor Start Assist Capacitor and Yes Yes No Relay Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Hard Shutoff TXV Yes Yes No Isolation Relay Yes No No Liquid Line Solenoid Valve No See Long---Line Application Guideline No Motor MasterControl or Yes No No Low Ambient Switch Support Feet Recommended No Recommended * For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split---System Longline Application Guideline. { Additional requirement for Low---Ambient Controller (full modulation feature) MotorMasterr Control. Accessory Description and Usage (Listed Alphabetically) 1. Ball--Bearing Fan Motor 6. Isolation Relay A fan motor with ball bearings which permits speed reduction An SPDT relay which switches the low--ambient controller out of while maintaining bearing lubrication. the outdoor fan motor circuit when the heat pump switches to Usage Guideline: heating mode. Required on all units when using MotorMasterr Usage Guideline: 2. Compressor Start Assist -- Capacitor and Relay Required in all heat pumps where low ambient kit has been added. Start capacitor and relay gives a hard boost to compressor motor at each start up. 7. Liquid--Line Solenoid Valve (LLS) Usage Guideline: An electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It is to Required for reciprocating compressors in the following be installed at the outdoor unit to control refrigerant off cycle applications: migration in the heating mode. Long line Usage Guideline: Low ambient cooling An LLS is required in all long line heat pump Hard shut off expansion valve on indoor coil applications to control refrigerant off cycle migration in Liquid line solenoid on indoor coil the heating mode. See Long Line Guideline. Required for single--phase scroll compressors in the 8. Low--Ambient Pressure Switch Kit following applications: A long life pressure switch which is mounted to outdoor unit Long line service valve. It is designed to cycle the outdoor fan motor in order Low ambient cooling to maintain head pressure within normal operating limits. The Suggested for all compressors in areas with a history of control will maintain working head pressure at low--ambient low voltage problems. temperatures down to 0_F(--18_C) when properly installed. 3. Compressor Start Assist — PTC Type Usage Guideline: Solid state electrical device which gives a soft boost to the A Low--Ambient Pressure Switch or MotorMasterr compressor at each start--up. Low--Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55_F Usage Guideline: (12.8_C). Suggested in installations with marginal power supply. 9. MotorMasterr Low--Ambient Controller 4. Crankcase Heater A fan--speed control device activated by a temperature sensor, An electric resistance heater which mounts to the base of the designed to control condenser fan motor speed in response to the compressor to keep the lubricant warm during off cycles. Improves saturated, condensing temperature during operation in cooling compressor lubrication on restart and minimizes the chance of mode only. For outdoor temperatures down to --20_F (--28.9_C), it liquid slugging. maintains condensing temperature at 100_F 10_F (37.8_C  Usage Guideline: 6.5_C). Required in low ambient cooling applications. Usage Guideline: Required in long line applications. A MotorMasterr Low Ambient Controller or Suggested in all commercial applications. Low--Ambient Pressure Switch must be used when 5. Evaporator Freeze Thermostat cooling operation is used at outdoor temperatures below 55_F (12.8_C). An SPST temperature--actuated switch that stops unit operation when evaporator reaches freeze--up conditions. Suggested for all commercial applications. Usage Guideline: Required when low ambient kit has been added. 6 Accessory Description and Usage (Listed Alphabetically) -- CONTINUED 10. Outdoor Air Temperature Sensor 14. Sound Hood Designed for use with Carrier Thermostats listed in this Wraparound sound reducing cover for the compressor. Reduces the publication. This device enables the thermostat to display the sound level by about 2 dBA. outdoor temperature. This device also is required to enable special Usage Guideline: thermostat features such as auxiliary heat lock out. Suggested when unit is installed closer than 15 ft. Usage Guideline: (4.577 m) to quiet areas, bedrooms, etc. Suggested for all Carrier thermostats listed in this Suggested when unit is installed between two houses less publication. than 10 ft. (3.05 m) apart. 11. Outdoor Thermostat 15. Thermostatic Expansion Valve (TXV) Bi--Flow An SPDT temperature--actuated switch which turns on A modulating flow--control valve which meters refrigerant liquid supplemental electric heaters when outdoor air temperature drops flow rate into the evaporator in response to the superheat of the below a user--selected set point. refrigerant gas leaving the evaporator. Usage Guideline: Usage Guideline: Electric supplemental heat applications in non--variable Accessory required to meet AHRI rating and system speed indoor units when electric heat staging is desired. reliability, where indoor not equipped. 12. Secondary Outdoor Thermostat Required in all heat pump applications designed with An SPDT temperature--actuated switch which turns on third--stage Puron refrigerant. of supplemental electric heaters when outdoor air temperature 16. Time--Delay Relay drops below the second--stage set point. An SPST delay relay which briefly continues operation of indoor Usage Guideline: blower motor to provide additional cooling after the compressor Outdoor thermostat applications where electric heater is cycles off. capable of 3--stage operation. Note: Most indoor unit controls include this feature. For those that 13. Snow Stand Rack do not, use the guideline below. Coated wire rack which supports unit 18 in. (457.2 mm) above Usage Guideline: mounting pad to allow for drainage from unit base. Accessory required to meet AHRI rating, where indoor Usage Guideline: not equipped. Suggested in the following applications: Heat pump installations in heavy snowfall areas. Heat pump installations in snow drift locations. Heat pump installations in areas of prolonged subfreezing temperatures. All commercial installations. 7 ELECTRICAL DATA MAX OPER VOLTS* COMPR FAN FUSE** or UNIT SIZE V/PH MCA CKT BRK MAX MIN LRA RLA FLA AMPS 18 48.0 9.0 0.50 11.8 20 24 62.9 10.9 0.60 14.2 25 30 72.5 13.5 1.40 18.3 30 36 208/230/1 253 197 75.0 15.1 1.10 20.0 30 42 105.5 15.5 1.40 24.0 40 48 108.0 19.0 1.40 25.2 40 60 144.2 24.4 1.52 32.0 50 * Permissible limits of the voltage range at which the unit will operate satisfactorily ** Time---Delay fuse. FLA --- Full Load Amps LRA --- Locked Rotor Amps MCA --- Minimum Circuit Amps RLA --- RatedLoadAmps NOTE: Control circuit is 24---V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. Complies with 2007 requirements of ASHRAE Standards 90.1 A--WEIGHTED SOUND POWER STANDARD TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment) UNIT SIZE RATING (dBA) 125 250 500 1000 2000 4000 8000 18 69 45 48 56 62 55 53 47 24 76 46 56 59 63 63 60 55 30 77 52 62 67 68 65 62 55 36 77 51 62 66 69 64 61 53 42 76 49 61 63 65 62 60 52 48 79 53 66 69 71 67 64 57 60 73 50 63 62 63 60 58 52 NOTE: Tested in accordance with AHRI Standard 270---08 (not listed in AHRI). A--WEIGHTED SOUND POWER WITH SOUND HOOD STANDARD TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment) UNIT SIZE RATING 125 250 500 1000 2000 4000 8000 18 68 47 48 56 61 55 52 46 24 74 47 57 59 62 61 58 51 30 77 52 62 67 67 65 62 54 36 76 52 62 66 67 64 60 52 42 74 50 61 63 64 61 58 49 48 79 54 66 69 70 67 64 56 60 73 51 64 62 63 59 56 49 NOTE: Tested in accordance with AHRI Standard 270---08 (not listed in AHRI). CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVICE) UNIT SIZE---SERIES REQUIRED SUBCOOLING ° F (° C) 18 11 (6.1) 24 11 (6.1) 30 10 (5.6) 36 10 (5.6) 42 10 (5.6) 48 14 (7.8) 60 15 (8.3) HP ONLY REPLACEMENT WITH PISTON INDOORS When the 25HCE4 is used as a replacement component in a system with a piston fan coil, use the indoor piston size specified below: PISTON SIZE UNIT SIZE FB4CNF FFM FPMA 18 0.052 0.050 0.050 24 0.057 0.057 0.056 30 0.067 0.070 0.067 36 0.070 0.072 0.069 42 0.078 48 0.084 60 =N/A 8 ring, refrigerant piping, and service. Allow 24 in. (609.6 mm) 18” (457.2 mm) clearance option described above is approved for outdoor units with wire grille coil guard only. Units When installing, allow sufficient space for airflow clearance, wiclearance to service end of unit and 48 in. (1219.2 mm) (above unit. For proper airflow, a 6–in. (152.4 mm) clearance on 1 side of unit and 12–in. (304.8 mm) on all remaining sides must be maintained. Maintain a distance of 24 in. (609.6 mm) between units or 18 in. (457.2 mm) if no overhang within 12 ft. (3.66 m) Position so water, snow, or ice from roof or eaves cannot fall directly on unit. NOTE:with louver panels require 24” (609.6 mm) between units. On rooftop applications, locate unit at least 6 in. (152.4 mm) above roof surface. DIMENSIONS -- ENGLISH 9 ring, refrigerant piping, and service. Allow 24 in. (609.6 mm) 18” (457.2 mm) clearance option described above is approved for outdoor units with wire grille coil guard only. Units When installing, allow sufficient space for airflow clearance, wiclearance to service end of unit and 48 in. (1219.2 mm) (above unit. For proper airflow, a 6–in. (152.4 mm) clearance on 1 side of unit and 12–in. (304.8 mm) on all remaining sides must be maintained. Maintain a distance of 24 in. (609.6 mm) between units or 18 in. (457.2 mm) if no overhang within 12 ft. (3.66 m) Position so water, snow, or ice from roof or eaves cannot fall directly on unit. NOTE:with louver panels require 24” (609.6 mm) between units. On rooftop applications, locate unit at least 6 in. (152.4 mm) above roof surface. DIMENSIONS -- SI 10 Wall 6” n of discharge air. (152.4) 12” 24” 24” (304.8) (609.6) Service (609.6) Service Wall 18” 12” (457.2) (304.8) 24” Wall (609.6) Service Clearances (various examples) 12” (304.8) 18” (457.2) 6” Wall 12” (152.4) (304.8) 24” (609.6) Service 24” (609.6) Service 18” Note: Numbers in ( ) = mm (457.2) : When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re--circulatio CLEARANCES IMPORTANT 11 kW 23.4 20.5 17.6 14.6 11.7 8.8 5.9 2.9 0.0 25HCE460FX4DNF061L25HCE448FB4CNP048L25HCE442FB4CNP042L25HCE436FB4CNP036L25HCE430FB4CNP030L25HCE424FB4CNP030L25HCE418FB4CNP018L BASED ON INDOOR ENTERING AIR AT 70◦F (21.1◦C) AND AT RATED CFM 1.1- 4.4 10.0 15.6 21.1 26.7 OUTDOOR TEMPERATURE 6.7- 12.2- 17.8- 10.0- 23.3- 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 0 80 70 60 50 40 30 20 10 F C BUILDING HEAT LOSS, UNIT INTEGRATED HEATING CAPACITY, MBTUH0 0 BALANCE POINT WORKSHEET 12 TESTED AHRI COMBINATION RATINGS NOTE: Ratings contained in this document are subject to change at any time. For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org Additional ratings and system combinations can be accessed via the Carrier database at: www.MyCarrierRatings.com For performance data at specific application &/or design conditions with various indoor unit combinations, the equipment performance calculator can be accessed at : http://rpmob.wrightsoft.com/ High Temp Low Temp Indoor Coil Model Cooling Model Number EER SEER HSPF Number Capacity E H ECOP HCOP Capacity Capacity 25HCE418A**30 FB4CNP018L 17,800 11.7 14 17,600 3.72 8.2 10,400 2.40 25HCE424A**30 FB4CNP030L 22,200 11.5 14 22,200 3.84 8.2 13,200 2.54 25HCE430A**30 FB4CNP030L 28,600 11.7 14 28,600 3.62 8.2 17,100 2.44 25HCE436A**31 FB4CNP036L 33,000 11.7 14 33,800 3.62 8.2 21,000 2.40 25HCE442A**30 FB4CNP042L 40,000 11.5 14 41,000 3.62 8.2 25,200 2.50 25HCE448A**30 FB4CNP048L 46,000 11.7 14 45,500 3.64 8.2 27,800 2.56 25HCE460A**30 FX4DN(B,F)061L 57,000 11.7 14 54,500 3.70 8.2 33,000 2.56 * AHRI = Air Conditioning, Heating & Refrigeration Institute * Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on: Cooling Standard: 80_F(27_C) db 67_F(19_C) wb indoor entering air temperature and 95_F(35_C) db air entering outdoor unit. High---Temp Heating Standard: 70_F(21_C) db indoor entering air temperature and 47_F(8_C) db 43° F (6_C) wb air entering outdoor unit. Low---Temp Heating Standard: 70_F(21_C) db indoor entering air temperature and 17_F (---8_C) db 15° F (---9_C) wb air entering outdoor unit. COP — Coefficient of Performance EER — Energy Efficiency Ratio HSPF — Heating Seasonal Performance Factor SEER — Seasonal Energy Efficiency Ratio 13 TotalKW**2.222.212.202.202.202.232.222.212.222.222.252.232.232.232.23 TotalKW**2.722.722.732.732.732.742.742.752.742.742.752.762.772.762.76 TotalKW**3.333.323.323.323.323.373.363.363.363.363.383.383.383.383.38 System System System Sens‡8.3910.6910.1913.1013.088.8811.4810.9213.5913.579.3512.2211.5913.9913.97 Sens‡11.1114.2513.6016.8316.8111.7615.2914.5617.4117.3912.3816.2615.4517.8817.86 Sens‡14.1518.1017.2521.3021.2715.2419.8418.8622.2822.2615.7020.5619.5122.6322.60 125 (51.7) 125 (51.7) 125 (51.7) Capacity MBtuh Capacity MBtuh Capacity MBtuh Total 15.5614.0612.9813.1013.0815.7714.2713.1913.5913.5715.9214.4413.3513.9913.97 Total 19.7717.9316.6216.8316.8120.0118.1816.8617.4117.3920.1818.3717.0517.8817.86 Total 25.2922.8621.1221.3021.2725.7123.2721.5222.2822.2625.8523.4121.6622.6322.60 TotalKW**1.971.961.951.951.951.981.971.971.971.972.001.991.981.981.98 TotalKW**2.412.422.422.422.422.432.432.442.442.442.442.452.462.452.45 TotalKW**2.982.982.972.972.973.023.023.013.013.013.033.033.033.033.03 System System System Sens‡8.8311.1510.6514.0013.989.3311.9511.3914.5414.529.8012.7112.0914.9914.97 Sens‡11.6514.8014.1517.8817.8612.3115.8615.1318.5318.5112.9416.8616.0519.0719.04 Sens‡14.8718.8217.9822.6722.6415.9720.6119.6323.7723.7416.4421.3520.3024.1524.13 115 (46.1) 115 (46.1) 115 (46.1) Capacity MBtuh Capacity MBtuh Capacity MBtuh Total 16.8615.2614.1014.0013.9817.1215.5114.3414.5414.5217.3115.7014.5314.9914.97 Total 21.3019.3317.9117.8817.8621.6019.6118.1918.5318.5121.8219.8418.4119.0719.04 Total 27.3024.6922.8222.6722.6427.8125.1823.2923.7723.7427.9925.3423.4524.1524.13 TotalKW**1.741.731.731.731.731.761.751.741.741.741.771.761.751.761.75 TotalKW**2.142.152.162.162.162.162.162.172.172.172.172.182.192.192.19 TotalKW**2.672.672.672.672.672.712.712.712.712.712.732.732.732.732.73 System System System Sens‡9.2611.5811.0813.7614.819.7612.3911.8415.4315.4110.2413.1612.5515.9315.91 Sens‡12.1515.3114.6618.7818.8112.8216.3815.6519.5519.5313.4617.4016.5920.1420.12 Sens‡15.5419.5018.6623.1723.8816.6621.3220.3425.1225.0917.1322.0721.0325.5525.52 105 (40.6) 105 (40.6) 105 (40.6) Capacity MBtuh Capacity MBtuh Capacity MBtuh Total 18.1016.4015.1614.9314.8118.4016.6915.4415.4315.4118.6316.9115.6615.9315.91 Total 22.7220.6219.1118.8818.8123.0720.9519.4319.5519.5323.3321.2019.6820.1420.12 Total 29.1526.3924.3924.0723.8829.7626.9524.9425.1225.0929.9627.1425.1225.5525.52 TotalKW**1.541.531.531.531.521.561.551.541.541.541.571.561.561.561.56 TotalKW**1.911.911.921.921.921.921.931.941.941.941.941.951.961.951.95 TotalKW**2.402.402.412.412.412.442.442.452.452.452.462.462.462.462.46 System System System 95 (35)Sens‡9.6611.9911.5014.2215.5810.1812.8212.2716.2716.2410.6613.6012.9916.8016.78 95 (35)Sens‡12.6215.7815.1418.7819.7013.3016.8716.1520.5020.4713.9417.9117.1021.1421.11 95 (35)Sens‡16.1620.1319.2923.9025.0117.3021.9721.0026.3626.3317.7822.7421.7126.8326.80 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) CONDENSER ENTERING AIR TEMPERATURES ° F (° C) CONDENSER ENTERING AIR TEMPERATURES ° F (° C) Capacity MBtuh Capacity MBtuh Capacity MBtuh Total 19.2717.4716.1615.8815.5819.6217.8016.4916.2716.2419.8818.0616.7416.8016.78 Total 24.0321.8220.2319.9319.7024.4422.2020.6020.5020.4724.7322.4920.8821.1421.11 Total 30.8727.9625.8625.4425.0131.5728.6026.4726.3626.3331.8128.8226.6926.8326.80 25HCE418 Outdoor Section With FB4CNP018L Indoor Section25HCE424 Outdoor Section With FB4CNP030L Indoor Section25HCE430 Outdoor Section With FB4CNP030L Indoor Section TotalKW**1.361.361.351.351.351.381.371.361.361.361.391.381.381.381.38 TotalKW**1.711.711.721.721.721.721.731.731.731.731.741.751.751.751.75 TotalKW**2.172.172.172.172.182.212.212.212.212.212.232.232.232.232.23 System System System Sens‡10.0612.3911.9014.6416.3010.5813.2212.6715.7117.0111.0714.0113.4117.6317.60 Sens‡13.0816.2415.6019.2820.5213.7617.3416.6221.2721.3514.4118.3817.5922.0822.05 Sens‡16.7520.7219.8924.5526.0617.9022.5921.6227.3727.4818.3923.3722.3428.0227.98 85 (29.4) 85 (29.4) 85 (29.4) Capacity MBtuh Capacity MBtuh Capacity MBtuh # Total 20.3818.4817.1016.7816.3020.7718.8617.4717.2017.0121.0819.1517.7517.6317.60 Total 25.2822.9621.3020.9420.5225.7323.3821.7021.4521.3526.0823.7122.0222.0822.05 Total 32.4729.4227.2226.7426.0633.2530.1527.9127.6227.4833.5330.3928.1528.0227.98 TotalKW**1.201.191.191.191.191.211.201.201.201.201.221.221.211.211.21 TotalKW**1.531.531.531.531.541.551.551.551.551.551.561.571.571.571.57 TotalKW**1.971.971.971.971.972.002.012.012.012.012.022.022.032.032.03 System System System Sens‡10.4412.7712.2715.0316.9710.9613.6113.0616.1317.7311.4614.4113.8117.1118.36 Sens‡13.5116.6816.0419.7521.3114.2017.7917.0721.1722.2014.8618.8518.0522.9722.94 Sens‡17.3221.3020.4625.1527.0518.4823.1722.2127.5328.5518.9723.9622.9429.1829.10 75 (23.9) 75 (23.9) 75 (23.9) Capacity MBtuh Capacity MBtuh Capacity MBtuh Total 21.4319.4417.9917.6416.9721.8819.8618.4018.0817.7322.2220.1918.7118.4818.36 Total 26.4724.0622.3221.9221.3126.9724.5322.7722.4522.2027.3524.8923.1222.9722.94 Total 33.9730.8028.5127.9927.0534.8531.6129.2828.8828.5535.1531.8929.5529.1829.10 EWB EWB EWB °F (° C) °F (° C) °F (° C) 72 (22.2)67 (19.4)62 (16.7)57 (13.9)72 (22.2)67 (19.4)62 (16.7)57 (13.9)72 (22.2)67 (19.4)62 (16.7)57 (13.9) 72 (22.2)67 (19.4)62 (16.7)57 (13.9)72 (22.2)67 (19.4)62 (16.7)57 (13.9)72 (22.2)67 (19.4)62 (16.7)57 (13.9) 72 (22.2)67 (19.4)62 (16.7)57 (13.9)72 (22.2)67 (19.4)62 (16.7)57 (13.9)72 (22.2)67 (19.4)62 (16.7)57 (13.9) 63 (17.2)†† 63 (17.2)†† 63 (17.2)†† 63 (17.2)†† 63 (17.2)†† 63 (17.2)†† 63 (17.2)†† 63 (17.2)†† 63 (17.2)†† EVAPORATOR AIRCFM 525 600 675 EVAPORATOR AIRCFM 700 800 900 EVAPORATOR AIRCFM 875 1050 1125 DETAILED COOLING CAPACITIES See notes on page 16 14 TotalKW**3.853.843.843.843.843.903.893.883.883.883.943.933.923.933.93 TotalKW**4.985.005.015.015.015.025.035.045.045.045.055.065.085.075.07 TotalKW**5.355.335.325.325.325.405.385.375.385.375.455.445.425.435.43 System System System Sens‡16.5121.2920.3224.6524.6217.4022.7521.6625.4025.3718.2624.1022.8926.0025.98 Sens‡19.5725.0523.9529.8229.7820.6626.8125.5830.8230.7821.7028.4627.0931.6431.60 Sens‡22.3828.7927.5234.2134.1723.6030.7629.3535.3035.2624.7932.6431.0736.1736.13 125 (51.7) 125 (51.7) 125 (51.7) Capacity MBtuh Capacity MBtuh Capacity MBtuh Total 28.9726.3324.4124.6524.6229.2826.6224.7125.4025.3729.5026.8524.9326.0025.98 Total 35.1431.9829.6829.8229.7835.5732.3930.1030.8230.7835.8632.7130.4231.6431.60 Total 40.1336.5934.0034.2134.1740.5637.0134.4335.3035.2640.8637.3434.7836.1736.13 TotalKW**3.463.443.433.433.433.503.493.483.483.483.543.533.523.523.52 TotalSystemKW**4.384.384.384.384.384.414.424.424.424.424.444.454.454.454.45 TotalSystemKW**4.834.804.784.774.774.884.854.834.834.834.934.914.884.894.89 System Sens‡17.3722.1721.2126.3126.2818.2823.6722.5927.1627.1319.1525.0723.8727.8527.82 Sens‡20.7526.2625.1632.1532.0821.8528.0626.8333.2733.2322.9029.7528.4034.2134.17 Sens‡23.7530.1728.9136.8736.8024.9832.2030.7938.1038.0626.1934.1532.5839.1339.09 115 (46.1) 115 (46.1) 115 (46.1) Capacity MBtuh Capacity MBtuh Capacity MBtuh Total 31.3728.5226.4526.3126.2831.7628.8826.8127.1627.1332.0329.1427.0727.8527.82 Total 38.4835.0432.5432.1532.0839.0035.5533.0433.2733.2339.3835.9233.4334.2134.17 Total 44.0140.1037.2536.8736.8044.5540.6437.7838.1038.0644.9741.0438.2039.1339.09 TotalKW**3.103.093.083.083.083.143.133.133.123.123.193.173.173.173.17 TotalSystemKW**3.893.883.883.883.883.923.923.923.923.923.963.963.963.963.96 TotalSystemKW**4.374.344.314.314.304.424.394.374.374.374.474.454.424.434.43 System Sens‡18.2023.0122.0527.4027.8219.1224.5423.4728.8028.7720.0125.9824.7929.5729.54 Sens‡21.7927.3126.2232.5234.0322.9129.1427.9235.3635.3123.9730.8829.5336.4136.36 Sens‡24.9931.4230.1437.4039.0726.2533.4832.0640.5440.4927.4835.4833.9141.7141.66 105 (40.6) 105 (40.6) 105 (40.6) Capacity MBtuh Capacity MBtuh Capacity MBtuh Total 33.6330.5928.3828.0327.8234.1031.0328.8128.8028.7734.4531.3529.1229.5729.54 Total 41.3937.7035.0134.4834.0342.0338.3035.6135.3635.3142.4938.7536.0636.4136.36 Total 47.4643.2340.1239.5439.0748.1543.8740.7740.5440.4948.6744.3841.2841.7141.66 TotalKW**2.792.782.772.772.772.832.822.822.822.822.872.862.862.862.86 TotalKW**3.473.483.483.483.483.513.513.523.523.523.543.553.553.553.55 TotalKW**3.963.933.913.913.904.013.993.963.963.964.064.044.024.024.02 System System System 95 (35)Sens‡18.9623.7822.8228.3229.2019.9025.3424.2630.3130.2420.8026.8125.6231.1331.10 95 (35)Sens‡22.7228.2427.1533.5435.6823.8530.1028.8735.8237.0924.9331.8530.5138.3038.25 95 (35)Sens‡26.1132.5231.2338.6341.0527.3934.6233.1841.1742.6128.6436.6535.0743.9643.91 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) CONDENSER ENTERING AIR TEMPERATURES ° F (° C) CONDENSER ENTERING AIR TEMPERATURES ° F (° C) Capacity MBtuh Capacity MBtuh Capacity MBtuh Total 35.7032.4830.1429.6729.2036.2533.0030.6430.3130.2436.6633.3731.0031.1331.10 Total 43.9140.0037.1536.5135.6844.6440.7037.8337.3637.0945.2041.2238.3638.3038.25 Total 50.5546.0042.6741.9441.0551.3546.7743.4242.9042.6152.0047.3744.0243.9643.91 25HCE436 Outdoor Section With FB4CNP036L Indoor Section25HCE442 Outdoor Section With FB4CNP042L Indoor Section25HCE448 Outdoor Section With FB4CNP048L Indoor Section TotalKW**2.502.502.502.502.502.542.542.542.542.542.582.582.582.582.58 TotalSystemKW**3.123.133.143.143.143.153.173.173.183.183.183.203.213.213.21 TotalSystemKW**3.593.573.553.553.543.643.623.613.603.603.693.673.663.663.66 System Sens‡19.6724.5023.5429.1230.4620.6326.0725.0031.0231.5821.5327.5726.3832.5532.51 Sens‡23.5429.0727.9834.4137.1224.7030.9429.7236.8238.6325.7832.7231.3839.9739.89 Sens‡27.1233.5332.2339.6942.7628.4235.6634.2142.3944.4629.6837.7236.1345.9945.88 85 (29.4) 85 (29.4) 85 (29.4) CONTINUED Capacity MBtuh Capacity MBtuh Capacity MBtuh # Total 37.6134.2331.7631.2230.4638.2534.8232.3331.8931.5838.7235.2532.7532.5532.51 Total 46.1442.0339.0238.3237.1246.9842.8239.8039.2038.6347.6043.4140.3839.9739.89 Total 53.2748.4544.9244.1142.7654.2249.3545.7945.1044.4654.9550.0446.4745.9945.88 TotalKW**2.232.242.252.252.262.272.282.292.292.292.312.322.332.332.33 TotalKW**2.782.812.832.832.842.812.842.862.862.872.842.872.892.892.90 TotalKW**3.233.223.223.213.213.283.283.273.273.263.333.333.323.323.32 System System System Sens‡20.3625.1924.2329.8531.6321.3426.7725.7031.8532.8322.2528.2927.1133.9533.84 Sens‡24.3129.8528.7635.2238.4725.4831.7330.5237.7040.0726.5733.5332.1939.8941.40 Sens‡28.0534.4533.1540.6544.3329.3736.5935.1543.4446.1430.6538.6937.1045.9247.65 75 (23.9) 75 (23.9) 75 (23.9) Capacity MBtuh Capacity MBtuh Capacity MBtuh Total 39.4235.8733.2832.6831.6340.1336.5333.9233.3932.8340.6837.0434.4033.9533.84 Total 48.1843.9040.7840.0238.4749.1144.7741.6340.9540.0749.8145.4442.2841.7641.40 Total 55.7550.6846.9946.1044.3356.8051.6847.9547.1646.1457.6552.4848.7248.0947.65 EWB EWB EWB °F (° C) °F (° C) °F (° C) 72 (22.2)67 (19.4)62 (16.7)57 (13.9)72 (22.2)67 (19.4)62 (16.7)57 (13.9)72 (22.2)67 (19.4)62 (16.7)57 (13.9) 72 (22.2)67 (19.4)62 (16.7)57 (13.9)72 (22.2)67 (19.4)62 (16.7)57 (13.9)72 (22.2)67 (19.4)62 (16.7)57 (13.9) 72 (22.2)67 (19.4)62 (16.7)57 (13.9)72 (22.2)67 (19.4)62 (16.7)57 (13.9)72 (22.2)67 (19.4)62 (16.7)57 (13.9) 63 (17.2)†† 63 (17.2)†† 63 (17.2)†† 63 (17.2)†† 63 (17.2)†† 63 (17.2)†† 63 (17.2)†† 63 (17.2)†† 63 (17.2)†† EVAPORATOR AIR EVAPORATOR AIR EVAPORATOR AIR CFM 1050 1200 1350 CFM 1225 1400 1575 CFM 1400 1600 1800 DETAILED COOLING CAPACITIES See notes on page 16 15 TotalKW**5.995.965.945.945.946.066.036.016.026.026.126.096.076.096.09 System Sens‡29.9038.4436.7641.1941.1431.5541.1739.2942.5442.4933.1343.7441.6343.6343.58 125 (51.7) Capacity MBtuh Total 48.4344.1040.9841.1941.1448.9744.6441.5242.5442.4949.3345.0341.9143.6343.58 TotalKW**5.345.325.295.295.295.415.385.365.365.365.475.455.435.445.43 System Sens‡31.3639.9638.2843.8143.7433.0442.7240.8645.3245.2634.6445.3743.2846.5746.49 115 (46.1) Capacity MBtuh Total 52.1847.5844.2143.8143.7452.8348.1944.8545.3245.2653.3048.6745.3246.5746.49 C). _ TotalKW**4.784.764.744.734.734.854.824.804.804.804.914.894.874.874.87 System F(27 _ Sens‡32.7441.3439.6849.4246.0834.4444.1642.2947.8047.7436.0646.8344.7649.1749.12 105 (40.6) Capacity MBtuh Total 55.6150.7147.1346.4346.0856.3951.4547.8747.8047.7456.9651.9948.4149.1749.12 h and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. TotalKW**4.304.274.254.254.254.374.344.324.324.324.434.404.384.394.39 System C), deduct 835 Btuh _ 95 (35)Sens‡34.0142.6240.9650.8748.1735.7445.4743.6150.0849.9937.3748.1846.1151.5651.49 F(27_ CONDENSER ENTERING AIR TEMPERATURES ° F (° C) Capacity MBtuh Total 58.7553.5849.7948.9848.1759.6654.4350.6450.0849.9960.3255.0751.2651.5651.49 25HCE460 Outdoor Section With FX4DN(B,F)061L Indoor Section TotalKW**3.883.863.843.843.833.953.923.913.903.904.023.993.973.973.97 F edb. System _ Sens‡35.2143.8242.1652.1450.0836.9546.6944.8355.7852.0538.6149.4447.3853.7553.68 85 (29.4) C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80 _ F(27 CONTINUED _ Capacity MBtuh # Total 61.6956.2552.2751.3450.0862.7157.2153.2252.4752.0563.4857.9453.9353.7553.68 TotalKW**3.533.503.483.483.473.593.573.553.553.543.663.633.613.613.61 System C) entering air at the indoor coil. For sensible capacities at other than 80 _ F ewb). All other indoor air temperatures are at 80 F(27 _ Sens‡36.3644.9743.3153.3451.8738.1347.8846.0157.1453.9739.8050.6548.5855.8355.71 _ 75 (23.9) F edb/63 _ Capacity MBtuh Total 64.4758.7654.6053.5951.8765.6159.8655.6654.7953.9766.4760.6756.4655.8355.71 EWB °F (° C) 72 (22.2)67 (19.4)62 (16.7)57 (13.9)72 (22.2)67 (19.4)62 (16.7)57 (13.9)72 (22.2)67 (19.4)62 (16.7)57 (13.9) 63 (17.2)†† 63 (17.2)†† 63 (17.2)†† : When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.— Entering Wet Bulb EVAPORATOR AIR CFM 1750 2000 2250 At TVA rating indoor condition (75 Total and sensible capacities are net capacities. Blower motor heat has been subtracted.Sensible capacities shown are based on 80 DETAILED COOLING CAPACITIES{ } (245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80# Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240---2008. If additional tubing lengt** Sys. kw is total of indoor and outdoor unit kilowatts.{{NOTEEWB 16 TotalSys-temKW 1.531.471.431.611.551.501.691.621.58 2.062.001.952.162.102.052.262.202.15 2.512.432.412.622.530.002.732.642.62 3.022.942.883.153.073.023.293.223.16 Integ 24.1924.3224.3223.8424.0124.0523.4723.6823.75 29.5529.4929.2629.2329.2329.1028.9028.9328.88 37.9137.9037.8037.4837.510.0037.0137.1137.07 45.4946.2346.7044.7145.4746.0143.9244.6845.28 67 (19.4) Capacity MBtuhTotal 24.1924.3224.3223.8424.0124.0523.4723.6823.75 29.5529.4929.2629.2329.2329.1028.9028.9328.88 37.9137.9037.8037.4837.510.0037.0137.1137.07 45.4946.2346.7044.7145.4746.0143.9244.6845.28 TotalSys-temKW 1.441.401.371.511.471.441.581.541.51 1.981.921.892.082.021.982.182.122.08 2.402.342.322.502.442.422.602.542.52 2.812.762.742.932.882.853.063.002.98 Integ 21.0021.3521.5420.6120.9521.2120.2220.5520.82 26.0226.1926.2025.6225.8825.9625.2125.5325.68 33.4233.8433.8832.8833.4233.5332.3432.9333.08 39.2539.8740.3838.6039.2039.7037.9538.5439.03 57 (13.9) Capacity MBtuhTotal 21.0021.3521.5420.6120.9521.2120.2220.5520.82 26.0226.1926.2025.6225.8825.9625.2125.5325.68 33.4233.8433.8832.8833.4233.5332.3432.9333.08 39.2539.8740.3838.6039.2039.7037.9538.5439.03 TotalSys-temKW 1.351.311.291.411.381.361.481.451.42 1.881.841.821.961.931.912.062.022.00 2.262.222.222.352.312.312.452.412.40 2.662.632.612.772.742.722.892.852.84 Integ 17.8718.1318.3317.5417.8018.0117.2117.4617.67 22.2722.5522.7821.9522.2022.4221.6021.8622.08 28.5729.1029.2828.0928.6028.7927.6228.1128.30 33.8634.3234.7033.3533.8034.1932.8333.2833.66 47 (8.3) Capacity MBtuhTotal 17.8718.1318.3317.5417.8018.0117.2117.4617.67 22.2722.5522.7821.9522.2022.4221.6021.8622.08 28.5729.1029.2828.0928.6028.7927.6228.1128.30 33.8634.3234.7033.3533.8034.1932.8333.2833.66 TotalSys-temKW 1.271.241.231.331.311.291.401.371.36 1.791.761.741.871.841.831.961.931.92 2.142.112.112.232.202.202.322.302.29 2.552.532.522.652.632.632.772.752.74 Integ 13.7113.8914.0413.4513.6313.7813.1913.3713.52 17.2817.4917.6716.9917.1917.3716.7216.9117.07 22.1222.5022.6421.7422.1222.2621.3721.7421.88 26.5026.8427.1426.0926.4326.7225.6926.0226.31 37 (2.8) Capacity MBtuhTotal 15.0715.2615.4314.7814.9815.1414.4914.6914.86 18.9919.2219.4118.6718.8919.0818.3718.5818.76 24.3024.7324.8823.8924.3124.4623.4823.8924.04 29.1229.4929.8228.6729.0429.3628.2328.6028.91 TotalSys-temKW 1.211.191.181.271.251.241.331.311.30 1.711.701.691.801.781.771.881.861.85 2.042.022.022.132.112.112.222.202.20 2.452.442.442.552.542.552.662.652.65 Integ 11.1411.2811.4010.9011.0511.1710.6410.8010.93 14.3014.4614.6014.0414.2014.3513.8013.9714.10 18.1918.5018.6117.8818.1818.2917.5717.8617.97 22.1222.4022.6621.7722.0522.2921.3721.6821.93 27 (-2.i8) OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C)Capacity MBtuhTotal 12.5412.7012.8312.2812.4512.5811.9812.1612.30 16.1016.2816.4415.8115.9916.1615.5415.7315.88 20.4920.8320.9620.1320.4720.5919.7820.1120.23 24.9025.2325.5124.5124.8225.1024.0724.4124.69 TotalSys-temKW 1.141.131.131.201.191.181.251.241.24 1.651.641.641.721.711.711.801.791.79 1.951.951.952.042.032.042.112.122.12 2.342.352.362.432.442.452.532.532.55 25HCE418 Outdoor Section With FB4CNP018L Indoor Section25HCE424 Outdoor Section With FB4CNP030L Indoor Section25HCE430 Outdoor Section With FB4CNP030L Indoor Section25HCE436 Outdoor Section With FB4CNP036L Indoor Section Integ 8.949.089.208.658.798.918.358.498.61 12.0812.4312.5611.6411.8412.0511.2811.4611.61 15.6415.9015.9915.3415.6115.7114.6615.2815.39 18.6018.9419.2718.0618.3818.6617.5017.8218.10 17 (-8.3) Capacity MBtuhTotal 9.809.9610.099.499.649.779.159.319.44 13.2513.6313.7812.7712.9913.2112.3712.5712.73 17.1617.4417.5416.8217.1217.2316.0816.7616.87 20.4020.7721.1319.8120.1520.4719.2019.5419.85 TotalSys-temKW 1.091.091.091.141.141.141.191.191.19 1.591.581.591.661.651.661.731.731.73 1.871.881.881.951.951.962.022.032.04 2.262.272.292.342.362.382.432.452.47 Integ 6.846.957.046.576.686.786.276.396.48 9.659.809.939.309.459.598.959.109.22 12.4512.7512.8512.0412.3112.4211.6211.8911.99 15.1615.4415.6914.6214.9015.1514.0614.3414.58 7 (-13.9) Capacity MBtuhTotal 7.457.577.667.157.277.386.836.957.05 10.5110.6610.8110.1210.2910.439.749.9010.03 13.5513.8713.9913.1013.4013.5112.6412.9413.05 16.5016.8117.0815.9116.2216.4815.3015.6015.87 TotalSys-temKW 1.031.041.041.081.081.091.131.131.14 1.531.541.541.601.601.611.671.671.68 1.801.811.821.871.891.901.951.961.97 2.182.202.232.262.282.312.352.372.40 Integ 4.844.935.014.584.674.754.284.364.45 7.457.577.697.087.217.326.716.846.95 9.709.9510.049.279.519.608.849.079.16 11.8912.1312.3511.3211.5611.7710.7310.9711.18 -3 (19.4) Capacity MBtuhTotal 5.265.365.444.985.085.164.654.744.84 8.098.238.357.697.847.967.307.447.55 10.5410.8110.9110.0810.3410.449.619.869.95 12.9213.1913.4312.3012.5612.8011.6611.9212.15 CFM 525600675525600675525600675 700800900700800900700800900 875105011258751050112587510501125 105012001350105012001350105012001350 INDOOR AIR 65 70 75 65 70 75 65 70 75 65 70 75 EDB °F (° C) HEAT PUMP HEATING PERFORMANCE See notes on page 18 17 TotalSys-temKW 3.473.373.313.623.523.453.793.683.60 3.843.763.724.003.923.874.524.434.37 4.504.404.344.704.604.534.924.804.73 Integ 53.6953.5153.2453.0952.9952.7452.4752.4352.23 61.8762.4262.7861.0261.5961.9858.1858.8659.33 73.3173.5473.3972.4172.6972.6371.5071.8171.82 67 (19.4) Capacity MBtuhTotal 53.6953.5153.2453.0952.9952.7452.4752.4352.23 61.8762.4262.7861.0261.5961.9858.1858.8659.33 73.3173.5473.3972.4172.6972.6371.5071.8171.82 TotalSys-temKW 3.343.263.203.483.403.353.643.553.50 3.673.613.573.823.753.724.324.254.20 4.324.234.194.514.424.384.724.634.57 Integ 48.0248.2148.1847.4247.7047.7546.8347.1347.26 53.3654.1954.7752.5153.2853.9849.8950.6651.35 64.2964.9565.3163.4464.1464.5562.5963.3363.78 57 (13.9) Capacity MBtuhTotal 48.0248.2148.1847.4247.7047.7546.8347.1347.26 53.3654.1954.7752.5153.2853.9849.8950.6651.35 64.2964.9565.3163.4464.1464.5562.5963.3363.78 TotalSys-temKW 3.183.143.103.323.273.243.473.413.38 3.483.443.423.623.583.564.124.074.04 4.134.084.074.324.274.254.524.464.43 Integ 41.5842.1042.4541.0041.4941.9140.4140.8941.30 45.6846.2646.7545.0045.5646.0443.0043.5243.96 55.2255.8856.4654.5055.1555.7153.8054.4254.97 47 (8.3) in total Sys. kilowatts. Capacity MBtuhTotal 41.5842.1042.4541.0041.4941.9140.4140.8941.30 45.6846.2646.7545.0045.5646.0443.0043.5243.96 55.2255.8856.4654.5055.1555.7153.8054.4254.97 heaters should be added to those values to obtain total Sys. capacity. TotalSys-temKW 3.012.982.963.143.103.093.283.243.21 3.313.293.283.453.423.423.933.893.87 3.953.923.914.144.114.094.334.294.28 Integ 32.4532.8133.1232.0232.3532.6631.5731.9232.20 35.6736.1036.4535.2035.5835.9233.8234.1734.48 43.2343.7044.1242.7143.1743.5742.2042.6343.02 37 (2.8) Capacity MBtuhTotal 35.6636.0536.3935.1935.5535.8934.7035.0735.39 39.2039.6740.0638.6839.1039.4737.1637.5537.88 47.5148.0348.4846.9447.4447.8846.3746.8547.28 TotalSys-temKW 2.872.842.842.982.962.953.113.093.07 3.173.163.173.293.283.293.673.663.66 3.793.773.783.973.963.964.164.144.14 Integ 26.8827.1727.4626.4726.7627.0226.0726.3626.60 29.7630.0930.4029.1929.6229.9426.4226.8427.15 36.1136.4536.7735.6936.0536.3735.2335.6435.96 27 (-2.i8) OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C)Capacity MBtuhTotal 30.2630.6030.9129.8030.1330.4229.3529.6829.95 33.5033.8834.2232.8633.3533.7129.7530.2230.57 40.6641.0541.4040.1940.5940.9539.6740.1240.49 TotalSys-temKW 2.712.722.722.822.812.822.932.922.93 3.003.003.023.113.123.133.503.503.51 3.603.613.633.763.773.793.943.943.96 25HCE442 Outdoor Section With FB4CNP042L Indoor Section25HCE448 Outdoor Section With FB4CNP048L Indoor Section 25HCE460 Outdoor Section With FX4DN(B,F)061L Indoor Section Integ 22.6423.4823.7521.9322.2822.6021.3221.6521.93 24.4624.8525.2023.7524.1424.4721.7222.0722.34 30.2330.6831.0729.5429.9730.3628.8329.2729.65 17 (-8.3) Capacity MBtuhTotal 24.8325.7526.0524.0624.4424.7923.3823.7424.05 26.8227.2527.6426.0526.4726.8423.8324.2124.50 33.1633.6534.0732.4032.8733.3031.6232.1032.52 TotalSys-temKW 2.592.592.602.692.692.712.792.802.81 2.872.892.912.972.993.023.343.353.38 3.463.483.513.623.643.673.783.803.83 Integ 18.3118.6418.9117.6417.9418.2117.0017.2817.53 19.6620.0120.3318.9319.2719.5516.8317.1217.35 24.6725.0525.3924.0124.3924.7323.3023.6924.03 7 (-13.9) Capacity MBtuhTotal 19.9320.2820.5819.2019.5219.8218.5018.8019.07 21.4021.7822.1220.6020.9721.2818.3118.6318.88 26.8527.2627.6226.1326.5426.9125.3625.7826.15 TotalSys-temKW 2.482.502.512.582.592.612.682.692.71 2.752.782.812.852.872.913.193.223.25 3.333.363.403.483.513.553.633.673.71 Integ 14.3514.6414.8913.6013.8714.1012.8813.1313.34 15.0415.3615.6414.2514.5414.7612.0712.3012.49 19.4519.7920.1018.7519.0819.4018.0118.3518.65 -3 (19.4) Capacity MBtuhTotal 15.5915.9116.1914.7815.0715.3314.0014.2714.51 16.3516.6917.0015.4815.8016.0513.1113.3713.58 21.1421.5121.8420.3820.7421.0819.5819.9420.28 CFM 122514001575122514001575122514001575 140016001800140016001800140016001800 175020002250175020002250175020002250 : When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. —Entering Dry Bulb INDOOR AIR 65 70 75 65 70 85 65 70 75 EDB °F (° C) The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to obta HEAT PUMP HEATING PERFORMANCE CONTINUED NOTE* The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted. The Btuh heating from supplement{ EDB 18 GUIDE SPECIFICATIONS AIR--COOLED, SPLIT--SYSTEM HEAT PUMP GENERAL 25HCE4 1--1/2 TO 5 NOMINAL TONS System Description Fans Outdoor--mounted, air--cooled, split--system heat pump unit — Condenser fan will be direct--drive propeller type, suitable for ground or rooftop installation. Unit consists of a discharging air upward. hermetic compressor, an air--cooled coil, propeller--type condenser — Condenser fan motors will be totally enclosed, 1--phase fan, and a control box. Unit will discharge supply air upward as type with class B insulation and permanently lubricated shown on contract drawings. Unit will be used in a refrigeration bearings. circuit to match up to a packaged fan coil or coil unit. — Shafts will be corrosion resistant. Quality Assurance — Fan blades will be statically and dynamically balanced. — Unit will be rated in accordance with the latest edition of — Condenser fan openings will be equipped with steel wire AHRI Standard 240. safety guards. — Unit will be certified for capacity and efficiency, and Compressor listed in the latest AHRI directory. — Compressor will be hermetically sealed. — Unit construction will comply with latest edition of — Compressor will be mounted on rubber vibration ANSI/ ASHRAE and with NEC. isolators. — Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit Condenser Coil will have C--UL approval. — Condenser coil will be air cooled. — Unit cabinet will be capable of withstanding Federal Test — Coil will be constructed of aluminum fins mechanically Method Standard No. 141 (Method 6061) 500--hr salt bonded to copper tubes which are then cleaned, spray test. dehydrated, and sealed. — Air--cooled condenser coils are pressure tested and the Refrigeration Components outdoor unit is leak tested. — Refrigeration circuit components will include liquid--line — Unit constructed in ISO9001 approved facility. shutoff valve with sweat connections, vapor--line shutoff Delivery, Storage, and Handling valve with sweat connections, system charge of Puronr — Unit will be shipped as single package only and is stored (R--410A) refrigerant, POE compressor oil, accumulator, and handled per unit manufacturer’s recommendations. and reversing valve. Warranty (for inclusion by specifying engineer) Operating Characteristics — The capacity of the unit will meet or exceed _____ Btuh — U.S. and Canada only. at a suction temperature of _____ _F/_C. The power PRODUCTS consumption at full load will not exceed _____ kW. Equipment — Combination of the unit and the evaporator or fan coil — Factory assembled, single piece, air--cooled heat pump unit will have a total net cooling capacity of _____ Btuh unit. Contained within the unit enclosure is all factory or greater at conditions of _____ CFM entering air wiring, piping, controls, compressor, refrigerant charge temperature at the evaporator at _____ _F wet bulb and Puronr (R--410A), and special features required prior to _____ _F/_C dry bulb, and air entering the unit at _____ field start--up. _F/_C. Unit Cabinet — The system will have a SEER of _____ Btuh/watt or greater at DOE conditions. — Unit cabinet will be constructed of galvanized steel, Electrical Requirements bonderized, and coated with a powder coat paint. — Available with dense grille only. — Nominal unit electrical characteristics will be _____ v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to _____ v. — Unit electrical power will be single point connection. — Control circuit will be 24v. Special Features — Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. 19 SYSTEM DESIGN SUMMARY 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01--in. wc. 2. Minimum outdoor operating air temperature without low--ambient operation accessory is 55_F (12.8_C). 3. Maximum outdoor operating air temperature for cooling mode is 125_F (51.7_C). 4. Minimum outdoor operating air temperature for heating mode is –30_F (–34.4_C). 5. Maximum outdoor operating air temperature for heating mode is 66_F (18.9_C). 6. For reliable operation, unit should be level in all horizontal planes. 7. For interconnecting refrigerant tube lengths greater than 80 ft (23.4 m) and/or elevation differences between indoor and outdoor units greater than 20 ft (6.1 m), consult Residential Piping and Longline Guideline and Service Manual available from equipment distribut- or. 8. If any refrigerant tubing is buried, provide a 6 in. (152.4 mm) vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in. (914.4 mm) may be buried without further consideration. Do not bury refrigerant lines longer than 36 in. (914.4 mm). 9. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. 10. Do not apply capillary tube indoor coils to these units. 11. Factory--supplied filter drier must be installed. Copyright 2015 Carrier Corp.S 7310 W. Morris St.S Indianapolis, IN 46231 Edition Date: 04/15 Catalog No:25HCE4---04PD Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: 25HCE4---03PD 20 Permit #: 964 Permit Date: 04/08/16 Permit Type: COMMERCIAL MECHANICAL Project Name: Nick Damianidis Applicant Name: Robert Rose Applicant Address: 22029 161st Ave SE Applicant, City, State, Zip: Monroe, WA 98272 Contact: Robert Rose Phone: 425-359-4819 Email: robert_ets@hotmail.com Scope of Work: Replace A/C Condenser Valuation: 2900.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Kristin Foster Property Parcel # Address Legal Description Owner Name Owner Phone Zoning 17324 SMOKEY POINT 581 Eating Places 00645300000800 OLYMPIA PIZZA DR (Restaurants) Contractors Contractor Primary Contact Phone Address Contractor Type License License # 22029 161st Ave MECHANICAL Energy Transfer Service Robert Rose 425-359-4819 Labor & Industries ENERGTS025PH SE CONTRACTOR Plan Reviews Date Review Type Description Assigned To Review Status COMMERCIAL 04/08/2016 BUILDING MECHANICAL Fees Fee Description Notes Amount Mechanical Fee (Enter Fixture Fee) $100.00 Mechanical Base Permit Fee $25.00 Mechanical Commercial Plan Review Table 4-1 $200.00 Total $325.00 Attached Letters Date Letter Description 04/11/2016 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 04/12/2016 robert rose 59134504 cc $325.00 Outstanding Balance $0.00 Notes Date Note Created By: 12/12/2019 Permit not signed. Filed under address Raelynn Jones Uploaded Files Date File Name 04/08/2016 1556919-BLD_964 Specs.pdf 04/08/2016 1556920-BLD_964 Application.pdf