Loading...
HomeMy WebLinkAbout21125 SMOKEY POINT BLVD_BLD928_2026 18204 59th Ave. Arlington, WA 98223 REVIEW COMMENT FORM (360) 403-3500 Project Name: Stillaguamish Tribes Permit No.: 927 Review Date: 3/16 Contact: Josh Wells Phone No.: 360-722-4350 Review Phase: 1st Round Report Date: 3/9/16 Reviewing Dept.: CED Applicant: Emerald Fire DWG Issue Date: 3/7/16 # Rev. Dwg. or Add’l Ref. City Comment Response/Resolution Spec. Ref. Check off 1. CJY 1 of 1 Head Quantity inconsistent with plan As-builts (shop drawings) will be required √ 2. CJY 1 of 1 TJI flange supports for bracing – structural load Verify through structural drawings √ calculation conducted? 3. CJY 1 of 1 Sammy Screw depth at 2 ½ inches or bracing at 10’ Field verify √ 4. CJY 1 of 1 Sidewinder screws in TJI’s – engineering call out Confirmation required √ 5. CJY FP1.01 Bracing of riser required Field verify √ 6. CJY FP1.01 Draft stops required in soffits, eaves, etc. with dry pipe Field verify √ sprinklers not exceeding 160 cubic feet 7. CJY U1.0 8” DCVA requires testing Field verify √ 8. CJY U1.2 Thrust blocking and or restraint system required Field verify √ 9. CJY U1.2 Hydro-static, flow, flush, and purity tests required Field verify √ 10. CJY FA1.01 Pull Station and Smoke required in Sprinkler Room Field verify √ 11. CJY FA1.01 Provide Battery Backup calculations Upon system certification √ 12. CJY Specs Specs call out 18 smokes, 5 horn strobes, 12 strobes, 3 As-builts (shop drawings) required upon √ pull stations and the plans do not show locations of all the completion. appliances. Also, no wiring diagram (Class A or B)? 13. CJY Misc. Acceptance tests required on all life safety systems prior to occupancy. 14. 15. 16. 17. 18. 19. 20. 21. Page 1 of 2 18204 59th Ave. Arlington, WA 98223 REVIEW COMMENT FORM (360) 403-3500 Project Name: Stillaguamish Tribes Permit No.: 927 Review Date: 3/16 Contact: Josh Wells Phone No.: 360-722-4350 Review Phase: 1st Round Report Date: 3/9/16 Reviewing Dept.: CED Applicant: Emerald Fire DWG Issue Date: 3/7/16 # Rev. Dwg. or Add’l Ref. City Comment Response/Resolution Spec. Ref. Check off 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. Page 2 of 2 Permit #: 928 Permit Date: 03/08/16 Permit Type: FIRE ALARM Project Name: River Rock Convenience Store Applicant Name: Stillaquamish Tribe of Indians Applicant Address: P.O. Box 277 Applicant, City, State, Zip: Arlington, WA 98223 Contact: Josh Wells Phone: 360-403-9123 Email: jwells@stillaquamish.com Scope of Work: Valuation: 13000.00 Square Feet: 4590 Number of Stories: 2 Construction Type: Occupancy Group: ID Code: Permit Issued: Permit Expires: Form Permit Type: Status: IN PROCESS Assigned To: Kristin Foster Property Parcel # Address Legal Description Owner Name Owner Phone Zoning STILLAGUAMISH 699 Other 21125 SMOKEY POINT 31050800300100 TRIBE OF Miscellaneous BLVD INDIANS Services NEC Contractors Contractor Primary Contact Phone Address Contractor Type License License # 12617 108th CONSTRUCTION White Security Systems 405-402-0366 Labor & Industries WHITESS044JP Avenue NE CONTRACTOR 19010 61st Ave CONSTRUCTION Labor and Elite Electric 360-653-6135 ELITELE132B9 NE Unit 1 CONTRACTOR Industries Plan Reviews Date Review Type Description Assigned To Review Status Ok to issue permit with redlined drawings and Plan 03/08/2016 FIRE ALARM BUILDING Review Comment Letter. Fees Fee Description Notes Amount Photocopies $12.00 Fire Alarm Plan Review Fee Valuation: 13K $309.03 Fire System Plan Review Table 4-1 $100.00 Total $421.03 Attached Letters Date Letter Description 03/09/2016 Building Permit Notes Date Note Created By: The building and systems have been under construction for a few months and it appeared that 03/09/2016 Chris Young the Tribe opted not to submit for plan review and inspection services and now have. CJY Uploaded Files Date File Name 03/09/2016 1510488-Plan Review Comment Letter.docx 03/08/2016 1509011-BLD_928 Application.pdf