Loading...
HomeMy WebLinkAbout17529 Osprey Rd_BLD5695_2025 i Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 591h Avenue NE • Arlington,WA 98223 • Phone (360)403-3551 Permit Number: BLD5695 Permit Type: Residential Plumbing Address/Parcel: 17529 Osprey Rd Completed (Month/Year): EXPIRED May 2024 Land Use ❑ Notice of Decision ❑ Bonding or Assignment of Funds ❑ Staff Report o Confidential Documents. Contact the ❑ Application City to obtain. ❑ Narrative ❑ Letters and Project Documents ❑ Legal Description ❑ Other: ❑ Vicinity Map ❑ Site Plan Civil ❑ Landscape Plan ❑ Issued Permit ❑ Complete Streets Checklist ❑ Application ❑ Traffic Impact Analysis ❑ Other Applications ❑ Snohomish County Traffic Mitigation Offer ❑ Construction Calculation Worksheet ❑ WSDOT Traffic Offer Form ❑ Approved Plans ❑ Tree Survey ❑ Review Comment Form ❑ Stormwater Drainage Report ❑ Letters and Project Documents ❑ Geotech Report ❑ Other Agency Permits ❑ Critical Area Evaluation Form ❑ Reports: ❑ SEPA Checklist o Drainage Report Pg: ❑ Public Notice Material o Stormwater Pg: ❑ Noticing and Related Documents o Geotech Pg: ❑ Water/Sewer Availability Certificate o All Other Reports ❑ Unanticipated Discovery Plan Form ❑ SEPA and Noticing Materials ❑ Aerial Photo of Site ❑ Inspections ❑ Proposed Building Materials ❑ As-Builts ❑ Lighting Plans and Lighting Cut Sheets ❑ Other: ❑ Color Elevations ❑ Design Matrix Building ❑ Plat Map ❑✓ Issued Permit ❑ Title Report ❑✓ Application ❑ Lot Closures ❑ Additional Applications ❑ Preliminary Civil Plans ❑ Approved Plans ❑ Archaeological Survey ❑ Site Plan o Confidential Documents. Contact the ❑ Letters and Project Documents City to obtain. ❑ Calculations ❑ Topography(Existing Conditions) ❑✓ Project Specification Manuals ❑ CC&R's ❑ Reports ❑ Deeds/Easements/Conveyances ❑ Certificate of Occupancy /Dedications ❑ Inspections ❑ Developer's Agreement ❑ Other: ❑ Recorded Copies Page 1 of 1 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 17529 OSPREY RD Permit#: 5695 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 00809200000700 DATE OF ISSUANCE. Scope of Work:LIKE FOR LIKE HWT CHANGE OUT Valuation: 3030.68 OWNER APPLICANT CONTRACTOR Ysaias Guerrero BARRON HEATING.COM BARRON HEATING&AC INC 17529 OSPREY RD 5100 PACIFIC HWY 5100 PACIFIC HWY STE 103 ARLINGTON,WA 98223-5953 FERNDALE,WA 98248 FERNDALE,WA 98248 360-676-1131 360-676-1131 LIC:600092564 EXP:03/31/2024 LIC:BARROHA179D7 EXP:10/23/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL PLUMBING CODE YEAR: 2018 STORIES: 1 CONST.TYPE: VB DWELLING UNITS: OCC GROUP: R-3;Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. MY [-/ $AIZTZOKf PETZM1777Kf� 11/14/2023 �Gr� 11/14/2023 Applicant Signature Date Building Official Date CONDITIONS Adhere to approved mechanical equipment.Call for final inspection.Permit shall be onsite for inspection. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/14/2023 Processing/Technology $25.00 11/14/2023 Inspection $75.00 11/14/2023 Plumbing Base $25.00 11/14/2023 Water Heater(Tank) $25.00 11/14/2023 Credit Card Service $4.50 Total Due: $154.50 Total Payment: $154.50 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail RESIDENTIAL PLUMBING APPLICATION • Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 This application is for new,repaired,altered or replaced plumbing installation for existing residences. Please fill out all pages of this application and include all information. The City of Arlington does not require a permit to stop leaks or clear stoppages,unless the piping is repaired,altered or replaced. Type of Permit: ❑ New Installation ❑ Addition 0 Alteration ❑ Repair Property Address: 17529 OSPREY ROAD Project Valuation: 3030.68 Lot#: 7 Parcel ID No.: 00809200000700 Preferred Contact: ❑ Owner ❑ Contractor Project Description:LIKE FOR LIKE 50gal NG HWT CHANGE OUT Owner Name: GUERRERO YSAIAS Home No.: 206-769-9809 Email Address: DWBSQRRL@YAHO.COM Cell No.: Mailing Address: 17529 OSPREY ROAD City: ARLINGTON State: WA Zip: 98223 Contractor Name: BARRON HEATING & A/C INC Office No.: 360-676-1131 Email Address: AMYE@BARRONHEATING.COM Cell No.: Mailing Address: 5100 PACIFIC HWY City: FERNDALE State: WA Zip: 98248 L&I Contractor License Number: BARROHA179D7 Expiration Date: 10/23/2024 • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) • Cross-Connection-Control may be required Proposed Interior Water Piping Size: ❑ 1/2" ❑ S/a" ❑ 3/4' ❑ 1" Proposed Interior Piping Material: ❑ CPVC ❑ Brass ❑ Copper ❑ PEX-AL-PEX ❑ PEX ❑ Galvanized Steel ❑ Other Proposed Exterior Water Piping Size: ❑ 1/2" ❑ S/a" ❑ 3/4" ❑ 1" ❑ 11/2 ❑ 2" Proposed Exterior Piping Material: ❑ PVC ❑ PE ❑ Copper ❑ PEX-AL-PEX ❑ PEX-AL-PE ❑ PEX ❑ Other Proposed Drain-Waste-Vent(DWV) ❑ Schedule 40 ABS DWV ❑ Copper ❑ Galvanized Steel ❑ Cast Iron Material: ❑ Schedule 40 PVC DWV ❑ Brass ❑ Other Proposed Drain-Waste-Vent(DWV) ❑ 1/2" ❑ s/e" ❑ 3/4" ❑ 1" ❑ 11/2 ❑ 2" ❑ 3" 04" Piping Size: PLUMBING PERMIT FEES (per fixture) Type of Fixture No.of Fixtures Cost per Fixture Subtotal Additional Plan Review fees x $75.00 = Alteration/repair piping x $15.00 = Backflow Assembly x $25.00 = Base Plumbing Fee 1 x $25.00 = $25.00 Bath Shower Combo x $ 15.00 = Building Main Waste x $25.00 = Clothes Washer x $ 15.00 = Dishwasher x $ 15.00 = REV03.2022 Pagel of 2 PLUMBING PERMIT FEES (per fixture) Drinking Fountain x $15.00 = Floor Drains x $15.00 = Grease Interceptor x $75.00 = Grease Trap x $25.00 = Hose Bibb x $15.00 = Icemaker Refri erator x $15.00 = Irrigation-per meter x $25.00 = Kitchen Sink&Disposal x $15.00 = Laundry Tray x $15.00 = Lavatory x $15.00 = Med Gas Pi in <-5 inlets outlets x $60.00 = Med Gas Piping>5 inlets/outlets(plus:5 5 x $5.00 = inlets outlets Miscellaneous-regulated by plumbing code,not x $15.00 = otherwise specified Pretreatment Interceptor x $15.00 = Re-inspection Fee x $75.00 = Roof Drains x $15.00 = Shower(only) x $15.00 = Sink bar,service,etc. x $15.00 = Toilets x $15.00 = Urinal x $15.00 = Vacuum Breakers x $25.00 = Water Heater 1 x $25.00 =25.00 MODEL NO.: RG250T6N Water Heater-Tankless x $25.00 = MODEL NO.: Permit Fee $25.0( Inspection Fee $75.00 Processing/Technology Fee $25.00 Total 125.00 I hereby certify that 1 am the❑ Owner, DApplicant, El Contractor,and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington,and the City of Arlington.A final inspection and approval shall be obtained when complete. A"V e&rd(&Y18"ram Amy EardIey 11 /13/2 Signature Print Name Date SAVE PRINT REV03.2022 Page 2 of 2 hR BRADFORD WHITE° W A T E R H E A T E R S Residential Atmospheric Vent Gas Water Heater The Atmospheric Vent FVIR Defender Safety System®Models Feature: Pj ■ Bradford White ICON System""*—Intelligent gas control with proven millivolt powered technology and built-in piezo igniter.A standard,off the shelf thermopile converts heat energy from the pilot flame into electrical energy to operate the gas valve and microprocessor. No need for external electricity. — Enhanced Performance—Proprietary algorithms provide enhanced First POP Hour Rating and tighter temperature differential. —Advanced Temperature Control System—Microprocessor constantly monitors and controls burner operation to maintain consistent and accurate water temperature levels. —Intelligent Diagnostics—An exclusive green LED light prompts the installer during start-up and provides ten different diagnostic codes to assist in troubleshooting. —Pilot On Indication—Flashing green LED provides positive indication that pilot is on. —Separate Immersed Thermowell—High-strength advanced polymer composite thermowell provides isolation between electric temperature sensor and surrounding water. No need to drain the tank when removing gas valve. ■ Advanced ScreenLok®Technology Flame Arrestor Design—Flame arrestor is designed to prevent ignition of flammable vapor outside of the water heater. ■ Resettable Thermal Switch—Proven and reliable bimetallic switch prevents burner and pilot operation in case of ongoing flammable vapors burning inside of the combustion chamber or restricted air flow. ■ Maintenance-Free—No regular cleaning of air inlet openings or flame arrestor is required under normal conditions. ■ Sight Window—Offers a view into the combustion chamber to observe the i operation of the pilot and burner. ■ Factory-Installed Hydrojet®Total Performance System—Sediment reducing a I device that also increases first hour rating of hot water while minimizing temperature build-up in tank. ■ Vitraglas® Lining—An exclusively engineered enamel formula that provides _ superior tank protection from the highly corrosive effects of hot water.This formula(Vitraglas°)is fused to the steel surface by firing at a temperature of over j 1600°F(871°C). —� ■ Insulation System—Non-CFC foam covers the sides and top of the tank, reducing heat loss.This results in less energy consumption, improved efficiencies, and jacket rigidity. Photo is of ■ Pedestal Base. RG240T6N ■ Water Connections-3/4" (19mm)NPT factory installed true dielectric fittings. ■ Factory-Installed Heat Traps. FEATURING: ■ Protective Magnesium Anode Rod. ■ 3x4"Snap Lock" Draft Diverter—Allows either 3" (76mm)or 4" (102mm)vent connections with inputs of 40,000 BTU/Hr. or less. Over 40,000 BTU/Hr. has the CON /� 4" (102mm) "Snap Lock" Draft Diverter. EsystemUP) ■ T&P Relief Valve—Installed. ■ Low Restrictive Brass Drain Valve—Durable tamper proof design. ■ NOx Emissions—Less than 40 ng/J. *May vary by region 6 or 10-Year Limited Tank Warranties/6 or 10-Year Limited Warranty on Component Parts. ca For more information on warranty, please visit www.bradfordwhite.com sw sP For products installed in USA,Canada,and Puerto Rico.Some states do not allow limitations on warranties.See complete copy of the warranty included with the heater. MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S.PATENTS:5,682,666;7,634,976;5,660,165;5,954,492;6,056,542;6,935,280;5,372,185;5,485,879;5,574,822;7,971,560;7,992,526;6,684,821; 6,442,178;7,334,419;7,866,168;7,270,087;7,007,748;5,596,952;6,142,216;7,699,026;5,341,770;7,337,517;7,665,211;7,665,210;7,063,132;7,063,133;7,559,293;7,900,589;5,943,984;8,082,888;5,988,117; 7,621,238;7,650,859;5,761,379;7,409,925;5,277,171;8,146,772;7,458,341;2,262,174.OTHER U.S.AND FOREIGN PATENT APPLICATIONS PENDING.CURRENT CANADIAN PATENTS:2,314,845;2,504,824;2,108,186; 2,143,031,2,409,271,2,548,958,2,112,515,2,476,685,2,239,007,2,092,105,2,107,012.Defender Safety System',ScreenLok^,Vitraglas®and Hydrojet®are registered trademarks of Bradford White'Corporation. 1101-B-1217 Residential Atmospheric Vent Gas Water Heater Atmospheric Vent Models Meet or exceed ASHRAE 90.1b(current standard)C.E.C.Listed NATURAL GAS AND LIQUID PROPANE GAS Recovery efficiency ranging up to 80 Nominal Recovery A B C D E F G H Approx. Model Capacity DOE 90'F Rise* Floor Jacket Vent Floor Floor Floor Floor Depth Shipping Number Rated First to Dia. Size to to to to Weight Storage Nat. LP Hour Uniform Nat. Nat. LP LP Flue T&P Gas Water Top of U.S. Imp. Volume BTU/Hr. BTU/Hr. Rating Energy U.S. Imp. U.S. Imp Conn. Conn. Conn. Conn. Heater Gal. Gal. (Gal.) Input Input (Gal.) Factor GPH GPH GPH GPH in. in. in. in. in. in. in. in. lbs. RG130T6N9 30 25 29 27,000 27,000 46 0.54 29 24 29 24 5915/16 16 3X4 493/4/563/a 1211/16 571/16 563/8 191/2 109 RG230T6N9 30 25 1 29 32,000 31,000 60 0.60 34 28 33 23 5915/16 1 18 3X4 497/8/563/8 1211/16 571/16 1 563/8 211/2 1 116 RG230S6N 30 25 29 30,000 32,000 49 0.54 32 37 32 27 491/4 20 3X4 385/s 1211/16 461/2 4511/16 231/2 113 RG140T6N• 40 33 38 34,000 34,000 64 0.59 37 31 37 31 611/2 18 3X4 511/2/60 1211/1s 591/4 5711/16 211/2 132 RG240T6N6 40 33 38 40,000 36,000 75 0.64 43 36 34 33 60V16 20 3X4 501/a/565/a 1211/16 579/16 563/4 231/2 134 RG240S6N0 40 33 38 40,000 35,000 69 0.58 43 36 41 34 513/4 22 3X4 41/471/4 1211/16 493/16 483/16 251h 139 RG150T6N• 50 42 47 34,000 34,000 75 0.63 37 31 37 31 605/16 20 3X4 50/561/8 1211/16 575/8 563/4 231/2 150 RG250T6N9 50 42 48 40,000 35,000 81 0.63 43 36 41 34 605/16 22 3X4 497/8/57 1211/16 571/8 563/4 251/2 154 RG25OL6N 48 40 47 40,000 35,000 77 0.63 43 36 41 34 5111/16 24 3X4 405/s 1211/16 493/8 483/16 271/2 170 RG250S6N6 50 42 47 50,000 48,000 75 0.63 54 45 52 45 1 605/8 1 22 4 497/8/57 1 1211/16 1 575/8 1 563/4 251/2 1 167 Nominal Recovery A B C D E F G H Approx. Model Capacity DOE 50'C Rise* Floor Jacket Vent Floor Floor Floor Floor Depth Shipping Number Rated First to Dia. Size to to to to Weight Storage Nat. LP Hour Uniform Nat. LP Flue T&P Gas Water Top of Volume kW kW Rating Energy Liters/ Liters/ Conn. Conn. Conn. Conn. Healer Liters (Liters) Input Input (Liters) Factor Hour Hour mm. mm. mm. mm. mm. mm. mm. mm. kg. RG130T6N• 114 110 7.9 7.9 174 0.54 110 110 1522 406 76x102 1264/1432 322 1449 1432 495 49 RG230T6N6 114 110 9.4 9.1 227 0.60 129 125 1522 1 457 76x102 1 1267/1432 322 1 1449 1432 1 546 53 RG230S6N 114 110 8.8 9.4 186 0.54 121 121 1251 508 76x102 982 322 1181 1160 597 1 51 RG140T6N0 151 144 10.0 9.9 243 0.59 139 139 1562 457 76x102 1308/1524 322 1505 1472 546 60 RG240T6N• 151 144 11.7 10.6 284 0.64 163 129 1532 508 76x102 1273/1438 322 1462 1441 597 61 RG240S6N• 151 144 11.7 10.3 262 0.58 163 155 1314 559 76x102 1041/1200 322 1249 1224 648 63 RG150T6N• 189 178 10.0 9.9 284 0.63 139 139 1532 508 76x102 1270/1432 322 1464 1441 597 68 RG250T6N6 189 182 11.7 10.3 1 307 0.63 163 155 1532 559 76x102 1267/1448 322 1470 1441 648 77 RG250L6N 182 178 11.7 10.3 292 0.63 163 155 11316 610 76x102 1032 322 1254 1224 699 70 RG250S6N0 189 1 178 14.7 14.1 284 0.63 204 197 11540 559 102 1267/1448 322 1464 1441 648 76 Propane models feature a Titanium Stainless Steel propane burner.For Propane(LP)models change suffix"N"to"X". For 10 year models,change suffix from"6"to 10". * Based on manufacturer's rated recovery efficiency. •Models feature optional top T&P location and must be specified when ordering. C Note:RG230S6N and RG250L6N do not have top T&P option. Uniform Energy Factor and First Hour Rating is based on the latest AHRI directory listings. General: Meets NAECA Requirements. optional Top T&P Valve All gas water heaters are certified at 300 PSI test pressure (2068 kPa)and 150 PSI working pressure (1034 kPa).All water connections are 3%"NPT(19mm)on 8" O (203mm)centers.All gas connections are'A All models design-certified by CSA International(formerly F G D AGA/CGA),ANSI standard Z21.10.1 and peak performance H O * O F rated. Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Suitable for Water(Potable)Heating and Space Heating. E Toxic chemicals,such as those used for boiler treatment, B o shall NEVER be introduced into this system.This unit may o NEVER be connected to any existing heating system or component(s)previously used with a non-potable water heating appliance. BRADFO WHITE® W A T E R H E A T E R S Ambler,PA For U.S.and Canada field service,contact your professional installer or local Bradford White sales representative. Sales 800-523-2931•Fax 215-641-1670/Technical Support 800-334-3393•Fax 269-795-1089•Warranty 800-531-2111•Fax 269-795-1089 International:Telephone 215-641-9400•Telefax 215-641-9750/www.bradfordwhite.com BRADFORD WHITE" Sales/Technical Support 866-690-0961/905-203-0600•Fax 905-636-0666/www.bradfordwhite.com W A T E R H E A T E R S Built to be the BeStTM 02017,Bradford White Corporation.All rights reserved. 1101-B-1217 Printed in U.S.A.