Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
16410 Smokey Point Blvd Ste 101_BLD6019_2025
i Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 591h Avenue NE • Arlington,WA 98223 • Phone (360)403-3551 Permit Number: BLD6019 Permit Type: Fire Alarm Address/Parcel: 16410 Smokey Point Blvd Ste 101 Completed (Month/Year): EXPIRED December 2024 Land Use ❑ Notice of Decision ❑ Bonding or Assignment of Funds ❑ Staff Report o Confidential Documents. Contact the ❑ Application City to obtain. ❑ Narrative ❑ Letters and Project Documents ❑ Legal Description ❑ Other: ❑ Vicinity Map ❑ Site Plan Civil ❑ Landscape Plan ❑ Issued Permit ❑ Complete Streets Checklist ❑ Application ❑ Traffic Impact Analysis ❑ Other Applications ❑ Snohomish County Traffic Mitigation Offer ❑ Construction Calculation Worksheet ❑ WSDOT Traffic Offer Form ❑ Approved Plans ❑ Tree Survey ❑ Review Comment Form ❑ Stormwater Drainage Report ❑ Letters and Project Documents ❑ Geotech Report ❑ Other Agency Permits ❑ Critical Area Evaluation Form ❑ Reports: ❑ SEPA Checklist o Drainage Report Pg: ❑ Public Notice Material o Stormwater Pg: ❑ Noticing and Related Documents o Geotech Pg: ❑ Water/Sewer Availability Certificate o All Other Reports ❑ Unanticipated Discovery Plan Form ❑ SEPA and Noticing Materials ❑ Aerial Photo of Site ❑ Inspections ❑ Proposed Building Materials ❑ As-Builts ❑ Lighting Plans and Lighting Cut Sheets ❑ Other: ❑ Color Elevations ❑ Design Matrix Building ❑ Plat Map ❑✓ Issued Permit ❑ Title Report ❑✓ Application ❑ Lot Closures ❑ Additional Applications ❑ Preliminary Civil Plans ❑✓ Approved Plans ❑ Archaeological Survey ❑ Site Plan o Confidential Documents. Contact the ❑✓ Letters and Project Documents City to obtain. ❑ Calculations ❑ Topography(Existing Conditions) ❑✓ Project Specification Manuals ❑ CC&R's ❑ Reports ❑ Deeds/Easements/Conveyances ❑ Certificate of Occupancy /Dedications ❑ Inspections ❑ Developer's Agreement ❑ Other: ❑ Recorded Copies Page 1 of 1 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 _ BUILDING PERMIT Er 16410 SMOKEY POINT BLVD STE 101 Permit#:6019 Parcel#:31052900100800 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:WIRELESS COMMUNICATOR INSTALLATION Valuation:500.00 APPLICANT CONTRACTOR SMOKEY POINT PROFESSIONAL FIRE PROTECTION INC/DAVID Fire Protection,Inc GROUP LLP MOW 1505 E 5TH ST FIRE PROTECTION INC/17410 ASH PO Box 12642 WAY,Ste 8 ARLINGTON,WA 98223-1125 LYNNWOOD,WA 98037 Bothell,WA 98082 425.290.9600 425-290-9600 LIC:601848 346 EXP:01/31/2025 LIC:FIRFPI*021ML EXP:07/13/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: FIRE ALARM CODE YEAR: 2021 STORIES: I CONST.TYPE: IA DWELLING UNITS: OCC GROUP: B;Business BUILDINGS: OCC LOAD: - PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBCl l0/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 0 6 . 18 . 2 4 i � - 06/14/2024 Applicant Signature Date Building Official Date CONDITIONS 9 Approved job copy shall be onsite for inspections.Adhere to approved plans.Call for inspections. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 06/14/2024 Web Only-Fire System Plan Review $200.00 06/14/2024 Credit Card Service $6.00 06/14/2024 Processing/Technology $25.00 06/14/2024 FACP/Transmitter-Replace $125.00 Total Due: $356.00 Total Payment: $356.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail i FIRE ALARM PERMIT APPLICATION • Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 Type of Permit: ❑ New Installation ® System Modification ❑ Phased Installation 16410 SMOKEY PT BLVD Property Address: Suite No.: Project Valuation: $500 . 00 Lot#: Parcel ID No.: 31052900100800 Preferred Contact: M Owner XApplicant N Contractor Project Description: INSTALLATION OF A FIRE ALARM WIRELESS COMMUNICATOR. THE NEW COMMUNICATOR WILL BE TIED INTO THE EXISTING FACP Owner Name: CUMULUS PARK HEALTH Phone No.: 425 . 315 .2501 Email Address: ACAMPBELLFARR@SONITROLPACIFIC.COM Cell No.: Mailing Address: City: State: Zip: Applicant Name: DAVID MOW w/ FIRE PROTECTION INC Phone No.: 425 .290 . 9600 Email Address: DAVID@FPISEATTLE.COM Cell No.: 17410 ASH WAY 98037 Mailing Address: Ste 8 City: LYNNWOOD State: WA Zip: Contractor Name: FIRE PROTECTION INC Phone No.: 425.290 . 9600 Email Address: DAVID@FPISEATTLE.COM Cell No.: Mailing Address:17410 ASH WAY, Ste 8 City: LYNNWOOD State:WA Zip: 98037 L&I Contractor License Number: FIREPI*021ML Expiration Date: 07/14/2025 SUBMITTAL REQUIREMENTS: Provide Information on All Equipment to be Installed Prior to Installation Submit electronic files of the follow: ® Complete and Scaled Plans Specification Sheets L� Wiring Diagrams (Point to Point Wiring) ® Electrical Plans,if applicable NOTE: All Central Station Monitoring must be UL or FM listed. FIRE ALARM SYSTEMS (105.7.3) ** DEVICES include separate individual portions of a Fire Alarm System such as: Initiating Devices, Notification Appliances, Flow Switch, Supervisory Switches, Magnetic Door Hold-Open Devices, Remote Annunciators, Pull Stations, Beam Detectors, and other such devices. (Each piece is one device) PLAN REVIEW FEES -shall be paid at time of application submittal Less than $5,000.00 = $200.00 $5,000.00 &over-based on project valuation (Plan Review Fee is 65%of project valuation per Fee Calculation Table 4-1) REV2022 Pagel of 2 REINSPECTION / PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application - review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour(1 hour minimum) $75.00 TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 72) Number of Devices" Device Fee Subtotal 1to2 $ 75.00 = $ 3 to 5 $125.00 = $ 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $ 41 to 100 $375.00 = $ 101 to 200 $475.00 = $ > 200 $500.00 plus$50.00 per 100 additional devices(roundup) Total Number of Devices = $500.00 + $ _ $ FACP/ TRANSMITTER Modification $125.00 = $ 125 PERMIT FEE SUBTOTAL $ ❑ NEW COMMERCIAL SYSTEM (NFPA 72) Number of Devices" Device Fee Subtotal 1 to 100 $350.00 = $ 101 to 200 $475.00 = $ > 200 $500.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $500.00 + $ _ $ FACP/TRANSMITTER New $200.00 = $ PERMIT FEE SUBTOTAL $ 125 PERMIT FEE TOTAL $ PLAN REVIEW FEE $ Processing/Technology Fee $25.00 TOTAL $ 1 hereby certify that 1 am the ❑Owner, ®Applicant, JK]Contractor,and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington,and the City of Arlington. DAVID MOW 06 . 04 .24 Signature Print Name Date REV2.2024 Page 2 of 2 COMMERCIAL FIRE ALARM CONTROL PANEL EXISTING FIRE ALARM CONTROL PANEL Model 5204 Fire Alarm Control , Panel and Optional Digital Communicator M3 Silent Knight's 5204 is compact and easy to install Q o and service, delivering features you'd expect to find in systems costing much more. The Silent Knight Model 5204 Fire Alarm Control Panel is a local fire evacuation control panel designed for applications requiring manual and automatic fire alarm as well as water flow and sprinkler supervisory service. Description for amp current output available �- for external devices. The basic 5204 unit offers local fire Compatible with 2- and 4-wire alarm control for up to four zones smoke detectors as well as and central station communications water flow and sounding with the optional UL Listed Model devices. 5205 Digital Communicator. The Two 1.5 amp supervised 5204 provides 3 amp current for notification circuits external devices and two 1.5 amp programmable for steady, supervised notification circuits. The pulsing, temporal or supervisory system is compatible with both 2- Auxiliary outputs of 1.5 amp at and 4-wire smoke detectors. • 12 or 24 VDC and 175 mA at The 5204 includes an annunciator 12VDC (only) inside the cabinet for annunciation Smoke verification, pre-alarm Ci S?' At MI r` T and operation. LEDs are visible delayand cross-zoning minimize Auxilia output ����V without opening the cabinet. g fi3UILDING DEPARTMENT false alarms. 1.5A @ 2 or 24 vocA�P������ Operation keys include SILENCE, 175 mA 12VDC DIALER RESET, and DISPLAY Two general purpose relays (2.5A dry contact, Form C) Mechan al Specification�ID� TROUBLES. Dimensi rQATE toBY • Optional plug-in UL Listed digital 14-7/, W x 15-518"H x 4- Remote annunciation is available communicator (Model 5205) A through the optional Model 5230. (37.8 4s.8 x 16.IP&� NGES AUTHORIZED g P • U /downloadin reduces UNLESS APPROVED BY THE P 9 ( Color: d This four-wire annunciator can installation time) Telep r�,P&PING INSPECTOR perform the same operation as the h e Requi main system annunciator and • Programmable from on-board Type of Jack RJ31X(2 require features English-language LCD touchpad or optional remote Approvals: display. annunciator(Model 5230) UL 864 NFPA 72 Central Station Reporting reS FeatU Accu-Zone diagnostics for on- site troubleshooting. Loca test Fi • The 4 Class B zones are Sign linC T � interchan eable to Class A Specifications Auxi1 ry n yste 19 -Rem to Si n using the Model 7181 Zone Electrical Specifications: FCC Part 68 a Part 15 Converter. Primary AC: 120 VRMS @ 60 hz,2.5A CSFM:7165 0J59 117 SUN 0 4 2024 Total Accessory Load:3A @ 12 or 24 VDC • Fuseless design reduces service Notification Circuits: New York City:11EA 429-92-E calls. • Field selectable 24 or 12 VDC Two Class B e for st ad , ul VDC. S1i J:ly.4 v -����• Programmable for steady,pulsing,temporal 11,,•�� power supply. and supervisory for sprinkler systemT--��� supervision. • COMMERCIALALARM CONTROLPANEL Model 5204 Fire Alarm Control Panel and Optional Digital Communicator Engineering Specifications The contractor shall provide a completely electrically supervised fire alarm control system. The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, alarm notification devices and visual annunciators.An optional digital communicator shall transmit fire alarm,trouble and supervisory signals to a central station. The controller shall be UL Listed for use under NFPA 72 standards. It shall provide power and control for four supervised detection zones, 2 supervised notification circuits, and, optionally, an approved plug-in digital communicator.The controller shall be Silent Knight 5204 or equivalent. There shall be four Class B detection zones. Products of combustion detection may be either 2-or 4-wire and shall be cross- listed by UL for use on the system.The detection zones shall be programmable to(1)be cross zones so that two adjacent detectors must sense products of combustion, (2)automatically reset a detector to verify that smoke exists, and (3)see a single detector in alarm%before an alarm is sounded, and, optionally,transmit a signal to the central station. There shall be two 1.5 amp supervised alarm notification circuits.They shall cause the bells/horns to ring steady/pulsing/ temporal through the premises until reset or silenced. The control shall be equipped with two auxiliary relays that shall be programmable to operate on (1)alarm, (2)trouble, (3)supervisory, (4)supervisory trouble and (5)system trouble.The relays shall maintain contact until cleared. The control shall have one on-board touchpad and shall support 3 remote annunciators. LEDs shall augment the display to clarify the system status to an operator.An integral touchpad shall be provided to operate, set up and interrogate the system. The optional plug-in digital communicator shall be UL Listed for use under NFPA 72 standards. It shall have the capability to supervise two telephone lines, seize the phone line and send the alarm signal on one or both lines without additional equipment. It shall be able to communicate to a central station in SIA, SK FSK(4/2), SK4/2 tone burst, SK 3/1, SESCOA 3/1, Radionics BFSK.The communicator shall sound a local trouble signal if the telephone service is interrupted for longer than 45 seconds and it shall transmit a signal indicating restoral of phone service.The optional digital communicator shall have the ability to send a test signal to the central station every 24 hours. The test signal shall be able to be transmitted at a specific time of day or night by setting a program within the communicator. The alarm signals transmitted to the central station shall indicate which zones are in alarm and which zones are in trouble. Restoral from an alarm shall also be transmitted by zone. Optional Accessories 5211 Auxiliary Relay 5220 Direct Connect Module 5230 Remote Annunciator Enables ground start phone lines. Used for city box and polarity Performs all the same functions as 4180 Status Display Module reversing direct wire applications. the on-board annunciator and Provides 16 outputs to give alarm 5541 Downloading Software and features an LCD English-language and trouble conditions by zone. 5530 Modem display and backlighting. Can be used to drive LED or For remote programming of 5204 5205 Digital Communicator graphic annunciators. Non- and other Silent Knight products Performs all the same functions as supervised. using an IBM PC or compatible the on-board annunciator and 7181 Fire Zone Converter computer. features LCD English-language Converts Class A zones to Class B display and backlighting. and vice versa. SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-446-6444 or in Minnesota 612-493-6435 FORM#350778, Rev.4/98 FAX: 612-493-6475 World Wide Web: http://www.silentknight.com Copyright©1998 Silent Knight NEW WIRELESS COMMUNICATOR 4WmTG7LAF02 / HW-TG7LVF02 CLSS-Enabled LTE Commercial Fire Alarm Communicators for AT&T° and Verizon° The dialer capture solution to connect commercial fire systems to central monitoring stations and the CLSS Cloud. Enabled by cooperation between Tel uard°and Honeywell',the HW-TG7L Fire Series starts with Telguard's modelTG-7FS and adds the powerful capabilities of Honeywell's Connected Life Safety Services(CLSS)Cloud. The CLSS LTE Fire Communicator transmits alarm signals from the fire panel over the LTE networks of AT&T(HW-TG7LAFO2)and Verizon(HW-TG7LVF02)to the designated monitoring station while leveraging connectivity with CLSS to enable powerfultools. Compliantwith 2019 and earlier editions of NFPA 72,the CLSS LTE Fire Communicator can f; serve as the sole communication path.For existing installations,all landlines dedicated to the master control unit can be replaced with a single CLSS LTE Fire Communicator because of its 5 or 60-minute supervision modes. HONEYWELL CONNECTED LIFE SAFETY SERVICES(CLSS) Honeywell CLSS is an innovative,all-in-one cloud platform that enables systems integrators and facilities managers to deliver an enhanced fire safety service,while maximizing the performance efficiencies offered by Honeywell's trusted detection and alarm systems.The CLSS platform enables users to: • Get a"bird's eye"view of all accounts TURBOCHARGED BY • Obtain real-time information on event generation,enabling diagnosis before dispatch HONEYWELL FORGED • Conduct tests and inspections using a mobile app(available in select markets) • Provide end users with multi-site asset information and event alerts A powerful software platform that enables Honeywell to provide real- TELGUARD INTERNET PORTAL time data and intelligence in its applications for connected buildings. Telguard makes adopting cellular easywith a secure internet portal that provides total account management of UL-listed Telguard cellular alarm communicators.Quickly access Telguard-based services 24/7. TELGUARD CELLULAR SERVICE Telguard Cellular Service provides AT&T and Verizon'LTE network coverage for allTelguard units.In Canada,cellular service maybe provided by Rogers,Bell,TELUS,orSaskTel. Telguard's Communication Center is UL compliant and provides seamless connectivity between the alarm panel,the Telguard family of products,and the central station.Telguard technical support provides a single point of contactfor both cellular service and Telguard product questions. FEATURES AND BENEFITS • Integration with CLSS enables monitoring • Minimizes false alarms by providing dual • Locking,red metal enclosure of event transmission data&management paths for self-tests • Two programmable supervisory trip outputs of device inventory from the CLSS mobile • Falls back to 3G/4G if an LTE network is not • Allows full data reporting for unlimited app and web portal(available only when available,for extended network coverage point-to-point signal details and maximum using Contact ID and point-based • 60-or 5-minute cellular supervision transmitting power for superior in-building reporting) available;180-seconds available in Canada penetration • Alarm format support for contact ID,SIA2, • Telephone line monitor built-in,with pulse(3x1,42),modem Ile,IIIa,and DMP standard line security • Certified for use on the AT&T and Verizon • Automatic self-test(daily or 6-hour) LTE networks • Available relay output fortripping the alarm ATW • Meets UL 864 requirements for sole control panel when a trouble condition primary or backup path communications occurs Honeywell I TELGUARD AMETEK' HW-TG7LAF02 / HW-TG7LVF02 TECHNICAL SPECIFICATIONS Electrical • EXDL-0:External Omnidirectional LTE • Power Consumption:40 mA(Standby) Antenna AT&T' •• • trademark of 160 mA(Transmission)with linksupervision • TP-PEM:Power&Expansion Module the AT&T •• L.P. enabled (supports 24V aux power from FACP to TG 7FS and multi le inputs) registered '' of • Source:l2 VAC,BUUmA UL listed plug-In P p ) transformer(included) STANDARDS AND CODES Canada.Bell Physical - • Y UL Listings: • Dimensions:7.5"(190.5 mm)H x 11.5"(292 864:Control units and accessories tar fire FORGE' registered trademarks mm)W x 3.5"(89 mm)D ' International, alarm systems • Shipping Weight:8lbs.(3.63 kg) • 365:Police Station connected burglar TeIguar• is a • •trademark • Operating Environment:32°F(0°C)to alarm units and systems 122°F(500C);up to 95%humidity(non- 1610:Central station burglar alarm units; of the Telular Corporation, condensing) ' of Line security services Radio Transceiver • 985:Household fire warning systems TELUSI is - registered trademark of • Transmit Power:200 mW in all bands • 1023:Household burglar alarm systems the TELUS Corporation. • LTE Bands:2,4&17 ULC Listings(AT&T only)*: Verizon'is a registered trademark • 3G Bands:2&5 • S545:Canadian household fire warning • Antenna:9"dipole with 2dBi gain 12 ft of systems ofVerizonTrademark cable and universal mounting bracket • S304:Canadian commercial burglary alarm This document is not intended to be • FCC:Part 15,22,24,27 and 68 compliant systems used for installation purposes.We • S559:Equipment for fire signal receiving ORDERING INFORMATION - • • •• information centres and systems try to HW-TG7LAF02:CLSS LTE Fire • C0123:Canadian household burglaryalarmup-to-date and accurate. cannot We Communicator for AT&T systems coverapplications or HW-TG7LVF02:CLSS LTE Fire *In Canada,cellular data may be carried by anticipate all requirements.All Communicator for Verizon Rogers,Bell",TELUS',orSaskTel. specifications • - • Accessories Available from Telguard: Other: without notice. • Low Loss,High Performance Cables: NYC Fire Department Certificate of Country of origin:U.S.A. • ACD-12:12 ft(3.7m) Approval#6316 ♦ ACD-35:35 ft(10.7m) • Los Angeles Fire Department Approved ♦ ACD-50:50 ft(15.2m) • CSFM:7300-1402:0109,7300-1402:0500 ♦ ACD-100:100 ft(30.5m) Visit www.tetguard.com for the most current • HGDL-0:High Gain Directional LTE product listings. Antenna Dealers& Technicians Honeywell CLSS Facility Managers LTE Telguard ' ® Network Communication Center FACP CLSS LTE Central Emergency Fire Communicator Station Fire Response Landline(Optional) Honeywell International,Inc. www.fire,honeywell com I Telguard HON-62049 I B 104-21 Honeywell TELGUARD www.te[guard.com 72021 Horeywet,International he AMETEK' ter:UMU �, �/ `/ PAR HEN TH FFPISEATTLE.0 M 17410 Ash Way,Ste B Lynnwood,WA 98037 425-290-960D FPISEA 90-960 OM WIRELESS COMMUNICATOR INSTALLAT � ON no NFPA 000805173 OPEMTIONAL MATRIX TELGUAR ROY L CATS SHEET p SHEET DESCRIPTION p�QpOTECJ./, FA 0.0 FIRE ALARM : TELGUARD INSTALLATION o w S SYSTEM OUTPUTS J PROJECTrd�J NFPA yyC R ul N Flro 8a1My Cwllrol CEPS LC�rtrttld SupenbMq STfrtFpt 9 1 THE EXISTING THREE-STORY BUILDING IS NOT SPRINKLED AND HAS AN EXISTING ADDRESSABLE FIRE ALARM CONTROL PANEL(SILENT KNIGHT SK-5204)LOCATED IN THE MAIN HALL ELECTRICAL ROOM. 01473 L y 2. A NEW UL LISTED WIRELESS CELLULAR COMMUNICATOR ES TO HE UL LISTED SU IS BEING INSTALLED AT THE FACP.ALL SIGNALS WILL BE TRANSMITTED BY ZONES TO THE UL LISTED SUPERVISING STATION. 3 THE NEW CELLULAR COMMUNICATOR SHALL TRANSMIT THE EXISTING FACP ZONES 1$ - rR IF A NO CHANGES TO THE EXISTING SYSTEM WILL BE MADE NO ADDITIONAL WORK IS INCLUDED IN THIS SCOPE L • of gu e OWNER I TENANT FIRE ALARM CONTRACTOR V (—= SECURE PACIFIC CORPORATION FIRE PROTECTION INC A •4F`off,. djY 11 8220 NORTH INTERSTATE AVE 17410 ASH WAY, Ste B o F p PORTLAND, OR 97217 LYNNWOOD, WA 98037 0 o ry Q CONTACT: ADAM CAMPBELL FARR CONTACT: DAVID MOW .S 'e ho A, yy PHONE 425,315,2501 PHONE: 425,290.9600 >¢¢p ACAMPBELLFARR®SONITROLPACIFIC.COM DAVID®FPISEATTLE.COM s r SYSTEM INPUTS A a c o'ic F G:H F_ _ _ ° �j l•°� ...°°. CODE INFORMA ON w w°° �. Manual FM AIMm PupSleYon _VfT TELGUARD HW-TG7LA(V)F02 - AUTHORITY HAVING JURISDICTION CITY OF ARLINGTON n 2 Smoke Deteetora �, 2 REVISION RECORD S Unused 1 DATE DESCRIPTION FIRE CODE INTERNATIONAL FIRE CODE, 2021 EDITION 4 Unused I d BUILDING USE AND OCCUPANCY: (B) - NOT SPRINKLED op. S Unused I _ 6 I tl! S Unused S STANDARDS 2021 IBC/IFC, 2017 NFPA 70, 2016 NFPA 72, CITY OF ARLINGTON STANDARDS 7 Fim AM—AC Power Falluro _�' 7 CLASSIFICATION OF SUPERVISING STATION : CENTRAL SUPERVISING STATION L6 fka AlatmS f4m Low Battery E REMOTE SUPERVISING STATION : SECURE PACIFIC, EVERETT WA ti 1 op..o'cult 0 _ �; 1 9 PRIME FIRE ALARM CONTRACTOR : FIRE PROTECTION INC .10 Ground FeuK �. O'_H t0 EXISTING FIRE ALARM PANEL(SILENT KNIGHT SK-5204) A B C'O B F O -- _. PARCEL NUMBERS: 31052900100800 A OT TYPICAL WIRING AND INSTALLATION DETAILS 1. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL LOCAL ADOPTED CODES VICINITY 2. ALL CIRCUITS MUST BE TESTED FOR OPENS, CONTINUITY, SHORTS, AND GROUNDS 3. INSTRUCTIONS FOR THE OPERATING, TESTING AND MAINTENANCE OF THE SYSTEM, ALONG WITH RECORD ORAONGS OTHERWISE REFERRED TO AS("AS-BUILT")AND EQUIPMENT SPECIFICATIONS SHALL BE PROVIDED TO THE OWNER ONCE THE FIRE ALARM SYSTEM HAS BEEN ACCEPTED BY THE AHJ. . NITE PLAN 4. ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURES LISTING AND THE AUTHORITY HAVING JURISDICTION (NFPA72 10.14.2.1). 5. THE SYSTEM WILL BE 100%PRE-TESTED, AN NFPA 72 COMPLETION FORM WILL BE FILLED OUT AND DATE: 06103/2024 PROVIDED TO THE AHJ AND THE ELECTRICAL PERMITS MUST BE SIGNED OFF PRIOR TO THE FIRE FINAL INSPECTION. PROJECT NAME 6- THE CELLULAR COMMUNICATOR REQUIRES A DEDICATED 120VAC 20AMP CIRCUIT, A NOTICE PLACED IN THE FACP SHALL DIRECT PERSONNEL TO THE LOCATION OF THE ELECTRICAL PANEL THAT 15 SUPPLYING Arlington DEDICATED POWER TO THE SYSTEM (NFPA72, SECTION 10.5,5.1). THE DEDICATED CIRCUIT BREAKER THAT SERVES THE FIRE ALARM SYSTEM SHALL BE LABELED AND SECURED AGAINST TAMPERING WITH A RED BREAKER LOCKOUT(NFPA72, SECTION 10.5.a2). Q FACP J m N 9 �_ 16410 Smokey Point MICE INSTALLATION REQUIREMENTS W Z co = a Blvd, Arlington, °a WA 98223 as w z _ F: ALARV D-VICE INSTALLA 0\ RE06 REM�N-S Y CITY OF ARLINGTON wts�rw-ttto _j o ry BUILDING DEPARTMENT ='^� �e. D'�SFR _ z Marysville �" n vc- r 1 SVC.CMINIMUM I APPROVED I V a [,VFT) ANAY faeK M'�Kr•t llp ,2- RECEI NVAc nrTusFNs "1 I 14 SVGK Everett DATE 2 BY SHEET TITLE NO CHANGES AUTHORIZED JU 0 4 024 Yn E"t B2"AF.F as^ I 3 UNLESS APPROVED'BYTHE - = PROJECT DETAILS BUILDING INSPECTOR I SHEET NUMBER Mukilteo No[I�S:lei YYY aaa"' FA 0.0 FIRE PROTECTION, INC. PO BON 12642 MILL CREEK,WA 98082 14251 290-9600 OR 1-800-681-1125 FAX (4251353-4546 June 3,2024 CITYOFARLINGTON - FIRE PREVENTION RE; FACP Wireless Communicator Installation 1 . THE EXISTING THREE-STORY BUILDING IS NOT SPRINKLED AND HAS AN EXISTING ADDRESSABLE FIRE ALARM CONTROL PANEL (SILENT KNIGHT SK-5204) LOCATED IN THE MAIN HALL ELECTRICAL ROOM. 2 . A NEW UL LISTED WIRELESS CELLULAR COMMUNICATOR (HW-TG7LAF02/TG7LVF02) IS BEING INSTALLED AT THE FACP. ALL SIGNALS WILL BE TRANSMITTED BY ZONES TO THE UL LISTED SUPERVISING STATION. 3. THE NEW CELLULAR COMMUNICATOR SHALL TRANSMIT THE EXISTING FACP ZONES. 4 . NO CHANGES TO THE EXISTING SYSTEM WILL BE MADE, NO ADDITIONAL WORK IS INCLUDED IN THIS SCOPE. INSTALLATION COMPANY Fire Protection, Inc. 14710 ASH WAY, STE 8 . LYNNWOOD, WA. 98204 WSCL# FIREPI*021ML UL CERT #608242-002 SITE ADDRESS CUMULUS PARK HEALTH 16410 SMOKEY POINT BLVD, ARLINGTON, WA 98223 APPROVED UL MONITORING COMPANY Secure Pacific 8220 North Interstate Ave, Portland, OR 97217 1 . 800 . 934 . 9304 CONTRACTUAL RESPONSIBLE PARTIES Installation; Monitoring Fire Protection, Inc. Should you have any further questions, please feel free to contact me directly. DAVID MOW, SET NICET-IV #120904 VP of OPERATIONS/Designer