Loading...
HomeMy WebLinkAbout6205 188th Pl Ne_BLD6252_2025 i Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 591h Avenue NE • Arlington,WA 98223 • Phone (360)403-3551 Permit Number: BLD6252 Permit Type: Commercial Mechanical Address/Parcel: 6205 188th PI Ne Completed (Month/Year): Decemeber 2024 Land Use ❑ Notice of Decision ❑ Bonding or Assignment of Funds ❑ Staff Report o Confidential Documents. Contact the ❑ Application City to obtain. ❑ Narrative ❑ Letters and Project Documents ❑ Legal Description ❑ Other: ❑ Vicinity Map ❑ Site Plan Civil ❑ Landscape Plan ❑ Issued Permit ❑ Complete Streets Checklist ❑ Application ❑ Traffic Impact Analysis ❑ Other Applications ❑ Snohomish County Traffic Mitigation Offer ❑ Construction Calculation Worksheet ❑ WSDOT Traffic Offer Form ❑ Approved Plans ❑ Tree Survey ❑ Review Comment Form ❑ Stormwater Drainage Report ❑ Letters and Project Documents ❑ Geotech Report ❑ Other Agency Permits ❑ Critical Area Evaluation Form ❑ Reports: ❑ SEPA Checklist o Drainage Report Pg: ❑ Public Notice Material o Stormwater Pg: ❑ Noticing and Related Documents o Geotech Pg: ❑ Water/Sewer Availability Certificate o All Other Reports ❑ Unanticipated Discovery Plan Form ❑ SEPA and Noticing Materials ❑ Aerial Photo of Site ❑ Inspections ❑ Proposed Building Materials ❑ As-Builts ❑ Lighting Plans and Lighting Cut Sheets ❑ Other: ❑ Color Elevations ❑ Design Matrix Building ❑ Plat Map ❑✓ Issued Permit ❑ Title Report ❑✓ Application ❑ Lot Closures ❑ Additional Applications ❑ Preliminary Civil Plans ❑ Approved Plans ❑ Archaeological Survey ❑✓ Site Plan o Confidential Documents. Contact the ❑ Letters and Project Documents City to obtain. ❑ Calculations ❑ Topography(Existing Conditions) ❑✓ Project Specification Manuals ❑ CC&R's ❑ Reports ❑ Deeds/Easements/Conveyances ❑ Certificate of Occupancy /Dedications ❑ Inspections ❑ Developer's Agreement ❑ Other: ❑ Recorded Copies Page 1 of 1 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 6205 188TH PL NE Permit#:6252 Parcel#:31051500401203 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:Ductless heat pump(mini split)install Valuation:34904.00 APPLIC, CONTRACTOR CITY OF ARLINGTON AIRPORT Northern Comfort Heating&Cooling Northern Comfort Heating&Cooling 6205 188TH PL NE 19618 Jordan Rd. 19618 Jordan Rd ARLINGTON,WA 98223 Arlington,WA 98223 Arlington,Wa 98223 425-588-4139 4255884139 1IC:604-753-001 EXP:11/30/2025 LIC:NORTHCH7620J EXP:09/11/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL MECHANICAL CODE YEAR: 2021 STORIES: 2 CONST.TYPE: IUB DWELLING UNITS: OCC GROUP: B;Business BUILDINGS: OCC LOAD: PERMIT APPROVAL . The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. "iftXZq."-VAi+ti"'tt� 12/02/2024 12/02/2024 Applicant Signature Date Building Official Date _ CONDITIONS ' 3"concrete pad with seismic bracing attached.Provide electrical disconnect.Lines shall be insulated;use of adhesive tapes are prohibited.Adhere to approved appliances.Approved job copy shall be onsite for inspections;if applicable.Call for final inspection. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES ' Date Description Fee Amount 12/02/2024 Web Only-Nt chanical Commercial Plan Review $479.17 12/02/2024 Processing/Technology $25.00 12/02/2024 Heat Pump-Condensing Unit $25.00 12/02/2024 Mechanical Base $25.00 12/02/2024 Credit Card Service $14.38 Total Due: $568.55 Total Payment: $568.55 Balance Due: $0.00 _ CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail i COMMERCIAL MECHANICAL APPLICATION • Community&Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping and must be accompanied by ELECTRONIC CONSTRUCTION DRAWINGS and CUT SHEETS and/or information outlined in the MECHANICAL SUBMITTAL REQUIREMENTS,if applicable. Type of Permit: o New Installation ❑ Addition ❑ Alteration ❑ Replaced ❑ Gas Piping Type I and Type II Hood Systems required submittal of the Commercial Mechanical Addenda Property Address. 6205 188th Place Northeast Arlington, project Valuation: $34,904.69 Lot#: Parcel ID No.: 31051500401200 Preferred Contact: ■Owner 71 Contractor Project Description: Install 2 ductless mini-split systems with 6 indoor head units Owner Name: City of Arlington Maintenance - Josh Grindy Office No.: Email Address: jgrindy@arlingtonwa.gov Cell No.: Mailing Address: 6295 188th PI NE Cit ;Arlington State: W4 zi :98223 Contractor Name: Northern Comfort Heating & Cooling Office No.: 425-588-4139 Email Address: northerncomfort.wa@gmail.com Cell No.: Mailing Address: 19618 Jordan Rd City: Arlington State: WA zip: 98223 L&I Contractor License Number: NORTHCH7620J Expiration Date: 9/11/2026 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured per IFGS, Section 415 • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of each appliance Gas Piping Specification and complete Schematic PAGE 3 O Not Applicable O CSST O Brass O Other Proposed Piping Material: O Black Steel O Galvanized Steel Proposed Piping Size: O 1/2" O 5/8" O 3/4" O 1" O 11/2 O 2" Inlet Pressure: Pressure Drop: Specific Gravity: I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above described property will be in accordance with the laws,rules and regulation of the State of Washington. p.� William Greenberg 11/21/2024 Signature Print Name Date REV03.2022 Page 1 of 3 MECHANICAL PERMIT FEES (per unit Type of Fixture No.of Units Cost per Unit Subtotal Additional Plan Review fees x $ 75.00 = $ Air Conditioning Unit 15 100 Btu h x $ 15.00 = $ Air Conditioning Unit> 100 Btu h x $ 25.00 = $ Air Conditioning Unit> 500 Btu/hp x $ 50.00 = $ Air Handling Units x $ 15.00 = $ Base Mechanical Fee $ 25.00 $ 25.00 Boiler<100Btu h>3h x $ 15.00 = $ Boiler>1 million Btu/h<50hp x $ 25.00 = $ Boiler>1.5 million Btu/h<50hp x $ 50.00 = $ Boiler>100Btu h 3-15h x $ 15.00 = $ Boiler>500Btu h 15-30hp x $ 25.00 = $ Commercial Hoods-Type I x $ 25.00 = $ Commercial Hoods-Type II x $ 50.00 = $ Diffusers x $ 15.00 = $ Dryer Ducting x $ 15.00 = $ Ductwork(drawings required) x $ 25.00 = $ Evaporative Coolers x $ 15.00 = $ Exhaust Ventilation Fans x $ 15.00 = $ Fireplace/Insert/Stove x $ 15.00 = $ Forced Air Heat<_100 Btu h x $ 15.00 = $ Forced Air Heat>100 Btu h x $ 25.00 = $ Gas Clothes Dryer x $ 15.00 = $ Gas Fired Air Conditioning Unit 15 100 Btu h x $ 15.00 = $ Gas Fired Air Conditioning Unit> 100 Btu h x $ 25.00 = $ Gas Fired Air Conditioning Unit> 500 Btu/hp x $ 50.00 = $ Gas Pi in <_ 5 units x $ 15.00 = $ Gas Piping for each additional unit > 5 x $ 2.00 = $ Heat Exchangers x $ 15.00 = $ Heat Pump-Condensing Unit 2 x $ 25.00 = $ Hot Water Heat Coils x $ 15.00 = $ Miscellaneous Appliance-regulated by x $ 15.00 _ $ mechanical code,not otherwise specified Package Units:5 100 Btu > 100 Btu x $ 25.00 $50.00 = $ Range/Cook top-Gas Fired x $ 15.00 = $ Refrigeration Unit<_100Btu h x $ 15.00 = $ Refrigeration Unit>100Btu h x $ 25.00 = $ Refrigeration Unit>500Btu h x $ 50.00 = $ Re-inspection fee all x $ 75.00 = $ Unit Heaters <_ 100 Btu h x $ 15.00 = $ Unit Heaters >100 Btu h x $ 25.00 = $ Variable Air Volume Boxes (part of Air x $ 10.00 = $ Conditioning System) Wall Heaters-Gas Fired x $ 25.00 = $ Water Heater- Gas Fired x $ 25.00 = $ Permit Fee $ 50 Table 4-8; Plan Review Fee $ Processing/Technology Fee $25.00 Total $ 75.00 REV2.2024 Page 2 of 3 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated REV2.2024 Page 3 of 3 O�Tu 3o k closc� I I 9 i 1 I� 0 a 4 0 1 -- ---- — —f-- -}-1---- S honz t 3ok u�� L) N o fS-�G�S MSZ-GS06NA 111 BTU/H WALL-MOUNTED INDOOR Job Name: System Reference: Date: _ GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control • Dual Barrier Coating applied to the heat exchanger,vanes and fan to prevent hydrophilic and hydrophobic dirt build-up • Optional Microparticle Filter designed to capture PM2.5 �mrr The outdoor unit powers the indoor unit,and should a power outage occur, the system is automatically restarted when power returns • Quiet operation • Smart Set:recalls a preferred preset temperature setting at the touch of a button • Built-in backup/auxiliary heater control available • Multiple fan speed options:Quiet,Low,Medium,High,Super-high,Auto • Multiple control options available: o Back-lit screen handheld remote controller(provided with the unit) o kumo cloud®smart device app for remote access o Third-party interface options o Wired or wireless controllers Specifications System Unit Type MSZ-GS06NA Cooling Capacity'' BTU/H 6,000 Heating Capacity2•' BTU/H 7,200 Voltage,Phase,Frequency 208/230,1,60 Guaranteed Voltage Range VAC 187-253 Electrical Voltage:Indoor-Outdoor,S1-S2 VAC 208/230 Voltage:Indoor-Outdoor,S2-S3 V DC 24 Short-circuit Current Rating[SCCR] kA 5 MCA A 1.0 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 30 Airflow Rate at Cooling,Dry CFM 134-160-222-307-381 Airflow Rate at Cooling,Wet CFM 121-144-200-276-343 Airflow Rate at Heating,Dry CFM 134-160-222-307-390 Sound Pressure Level[Cooling] dB[A] 19-22-30-37-45 Indoor Unit Sound Pressure Level[Heating] dB[A] 19-22-30-37-43 Drain Pipe Size In.[mm] 5/8[15.88] Coating on Heat Exchanger Dual Barrier Coating External Finish Color Munsell 1.OY 9.2/0.2 Unit Dimensions W X D X H:In.[mm] 31-7/16 x 9-1/8 x 11-5/8[798 x 232 x 2951 Package Dimensions W x D x H:In.[mm] 33-1/2 x 12 x 14[850 x 300 x 350] Unit Weight Lbs.[kg] 23[10.4] Package Weight Lbs.[kg] 26[11.5] Refrigerant Type R410A Gas Pipe Size O.D.[Flared] In.[mm] 3/8[9.52] Piping Liquid Pipe Size O.D.[Flared] In.[mm] 1/4[6.35] NOTES: Conditions 'Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 IDS,75 WB 2Heating at 47°F(Indoor//Outdoor) °F 70 DB,60 WB//47 DB,43 WB 'Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit.For reference to connected capacity charts,please refer Multi-zone Outdoor Unit Operational Performance. Specifications are subject to change without notice. ©2023 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. INDOOR UNIT ACCESSORIES: 16 BACnet®and Modbus®Interface ❑ PAC-UKPRC001-CN-1 CN24 Relay Kit ❑ CN24RELAY-KIT-CM3 IT Extender ❑ PAC-WHS011E-E kumo station®for kumo cloud® ❑ PAC-WHS01 HC-E Control Interface System Control Interface ❑ MAC-3341F-E Thermostat Interface ❑ PAC-US444CN-1 Thermostat Interface ❑ PAC-US445CN-1 USNAP Adapter ❑ PAC-WHS01UP-E Wireless Interface for kumo cloud® ❑ PAC-USWHS002-WF-2 Remote Sensor Wired Remote Sensor ❑ M21 EAA307 Wireless temperature and humitity sensor for kumo cloud® ❑ PAC-USWHS003-TH-1 Deluxe Wired MA Remote Controllert ❑ PAR40MAAU Wired Remote Controller Simple Ductless Wired Remote Controller ❑ PAC-SDW01 RC-1 Simple MA Remote Controllert ❑ PAC-YT53CRAU-J Touch MA Controllert ❑ PAR-CT01 MAU-SB kumo touch'RedLINK'Wireless Controller ❑ MHK2 Wireless Remote Controller Lockdown bracket for remote controller ❑ RCMKPICB Blue Diamond(Advanced)Mini Condensate Pump w/Reservoir&Sensor(208/230V)[recommended] ❑ X87-721 Blue Diamond(MicroBlue)Mini Condensate Pump(110/2081230V)up to 18,000 BTU/H ❑ X86-003 Blue Diamond Alarm Extension Cable-6.5 Ft. ❑ C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps ❑ C21-014 Blue Diamond Sensor Extension Cable—15 Ft. ❑ C13-103 Condensate Drain Pan Level Sensor/Control ❑ SS610E Fascia Kit for MicroBlue Pump,mounts the MicroBlue and sensor directly beneath indoor unit ❑ T18-016 Refco Condensate Pump(100-240 VAC) ❑ GOBI-11 Refco Condensate Pump(100-240 VAC)up to 120,000 BTU/H ❑ COMBI Sauermann Condensate Pump ❑ S130-230 Disconnect Switch (30A/600V/UL)[fits 2"X 4"utility box]-Black ❑ TAZ-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White ❑ TAZ-MS303W Filter Anti-allergy Enzyme Filter ❑ MAC-408FT-E Microparticle(PM2.5)Filter ❑ MAC-EMF515FT-E 15'x 1/4"x 15'/3/8"Lineset(Twin-Tube Insulation) ❑ MLS143812T-15 Lineset 30'x 1/4"x 30'/3/8"Lineset(Twin-Tube Insulation) ❑ MLS143812T-30 50'x 114"x 50'/3/8"Lineset(Twin-Tube Insulation) ❑ MLS143812T-50 65'x 1/4"x 65'/3/8"Lineset(Twin-Tube Insulation) ❑ MLS143812T-65 NOTES: tRequires MAC-3341F-E "M-Series EZ FIT®Recessed Ceiling Cassette,Floor-mount and Wall-mount Allows indoor units to connect to an MA Controller: Deluxe MA Remote Controller Simple MA Controller Touch MA Controller Specifications are subject to change without notice. ©2023 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. INDOOR UNIT DIMENSIONS: I6 Unit: inch 7/16xl Oblong hole 1/16xl3/I6 Oblong hole Installation late 3-1/8 8 7/8 8 7/8 3 1/8 31-7/16 30-15/16 1/4 0 6-I/8 6-I/8 2-3/8 13-5/16 13-9/16 2-1/8 9-1/8 Ai r i n al I hole m3 3/16 Indoor unit l� �J Installation Plate Pi in 1-3/4 1-15/16 24-3/8 �5-I5/8 4 3/16�= Drain hose 2-3/8m� — ; � � A I f 0 U t oM Insulation o1-9/16 10.1) c Liquid line o1/4 19-11/16(Flared connection o1/4) 2-3/I6 15/16 a Gas line o3/816-15/16 -3/1 6 (Flared connection:o3/8(GS06/09/12NA),o1/2(GS15NA)) Wireless remote Drain hose Insulation o1-1/8 O.D Connected part 05/8 O.D controller 1340 Satellite Boulevard Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com ETA�s FORM#MSZ-GS06NA-U1-202304 Intertek Specifications are subject to change without notice. ©2023 Mitsubishi Electric Trans,HVAC US LLC.All rights reserved. MSZ-GS09NA Job Name: System Reference: Date: _ GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control • Dual Barrier Coating applied to the heat exchanger,vanes and fan to prevent hydrophilic and hydrophobic dirt build-up • Optional Microparticle Filter designed to capture PM2.5 �mrr The outdoor unit powers the indoor unit,and should a power outage occur, the system is automatically restarted when power returns • Quiet operation • Smart Set:recalls a preferred preset temperature setting at the touch of a button • Built-in backup/auxiliary heater control available • Multiple fan speed options:Quiet,Low,Medium,High,Super-high,Auto • Multiple control options available: o Back-lit screen handheld remote controller(provided with the unit) o kumo cloud®smart device app for remote access o Third-party interface options o Wired or wireless controllers Specifications System Unit Type MSZ-GS09NA Cooling Capacity'' BTU/H 9,000 Heating Capacity2•' BTU/H 10,900 Voltage,Phase,Frequency 208/230,1,60 Guaranteed Voltage Range VAC 187-253 Electrical Voltage:Indoor-Outdoor,S1-S2 VAC 208/230 Voltage:Indoor-Outdoor,S2-S3 V DC 24 Short-circuit Current Rating[SCCR] kA 5 MCA A 1.0 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 30 Airflow Rate at Cooling,Dry CFM 134-160-222-307-381 Airflow Rate at Cooling,Wet CFM 121-144-200-276-343 Airflow Rate at Heating,Dry CFM 134-160-222-307-390 Sound Pressure Level[Cooling] dB[A] 19-22-30-37-43 Indoor Unit Sound Pressure Level[Heating] dB[A] 19-22-30-37-43 Drain Pipe Size In.[mm] 5/8[15.88] Coating on Heat Exchanger Dual Barrier Coating External Finish Color Munsell 1.OY 9.2/0.2 Unit Dimensions W X D X H:In.[mm] 31-7/16 x 9-1/8 x 11-5/8[798 x 232 x 2951 Package Dimensions W x D x H:In.[mm] 33-1/2 x 12 x 14[850 x 300 x 350] Unit Weight Lbs.[kg] 23[10.4] Package Weight Lbs.[kg] 26[11.5] Refrigerant Type R410A Gas Pipe Size O.D.[Flared] In.[mm] 3/8[9.52] Piping Liquid Pipe Size O.D.[Flared] In.[mm] 1/4[6.35] NOTES: Conditions 'Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 IDS,75 WB 2Heating at 47°F(Indoor//Outdoor) °F 70 DB,60 WB//47 DB,43 WB 'Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit.For reference to connected capacity charts,please refer Multi-zone Outdoor Unit Operational Performance. Specifications are subject to change without notice. ©2023 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. INDOOR BACnet®and Modbus®Interface PAC-UKPRC001-CN-1 CN24 Relay Kit CN24RELAY-KIT-CM3 IT Extender PAC-WHS011E-E kumo station®for kumo cloud® PAC-WHS01 HC-E Control Interface System Control Interface MAC-3341F-E Thermostat Interface PAC-US444CN-1 Thermostat Interface PAC-US445CN-1 USNAP Adapter PAC-WHS01 UP-E Wireless Interface for kumo cloud® PAC-USWHS002-WF-2 Remote Sensor Wired Remote Sensor M21 EAA307 Wireless temperature and humitity sensor for kumo cloud® PAC-USWHS003-TH-1 Deluxe Wired MA Remote Controllert PAR40MAAU Wired Remote Controller Simple Ductless Wired Remote Controller PAC-SDW01 RC-1 Simple MA Remote Controllert PAC-YT53CRAU-J Touch MA Controllert PAR-CT01 MAU-SB kumo touch'RedLINK'Wireless Controller MHK2 Wireless Remote Controller Lockdown bracket for remote controller RCMKPICB Blue Diamond(Advanced)Mini Condensate Pump w/Reservoir&Sensor(208/230V)[recommended] X87-721 Blue Diamond(MegaBlue Advanced)Condensate Pump w/Reservoir&Sensor X87-835 Blue Diamond Alarm Extension Cable—6.5 Ft. C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps C21-014 Blue Diamond Sensor Extension Cable—15 Ft. C13-103 Condensate Drain Pan Level Sensor/Control SS610E Fascia Kit for MicroBlue Pump,mounts the MicroBlue and sensor directly beneath indoor unit T18-016 Refco Condensate Pump(100-240 VAC) GOBI-11 Refco Condensate Pump(100-240 VAC)up to 120,000 BTU/H COMBI Sauermann Condensate Pump S130-230 Disconnect Switch (30A/600V/UL)[fits 2"X 4"utility box]-Black TAZ-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White TAZ-MS303W Filter Anti-allergy Enzyme Filter MAC408FT-E Microparticle(PM2.5)Filter MAC-EMF515FT-E NOTES: tRequires MAC-3341F-E "M-Series EZ FIT®Recessed Ceiling Cassette,Floor-mount and Wall-mount Allows indoor units to connect to an MA Controller: Deluxe MA Remote Controller Simple MA Controller Touch MA Controller Specifications are subject to change without notice. ©2023 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. INDOOR UNIT DIMENSIONS: I ' Unit: inch 7/16xl Oblong hole 1/16xl3/I6 Oblong hole Installation late 3-1/8 8 7/8 8 7/8 3 1/8 31-7/16 30-15/16 1/4 0 6-I/8 6-I/8 2-3/8 13-5/16 13-9/16 2-1/8 9-1/8 Ai r i n al I hole m3 3/16 Indoor unit l� �J Installation Plate Pi in 1-3/4 1-15/16 24-3/8 �5-I5/8 4 3/16�= Drain hose 2-3/8m� — ; � � A I f 0 U t oM Insulation o1-9/16 10.1) c Liquid line o1/4 19-11/16(Flared connection o1/4) 2-3/I6 15/16 a Gas line o3/816-15/16 -3/1 6 (Flared connection:o3/8(GS06/09/12NA),o1/2(GS15NA)) Wireless remote Drain hose Insulation o1-1/8 O.D Connected part 05/8 O.D controller 1340 Satellite Boulevard Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com ETA�s FORM#MSZ-GS09NA-U1-202304 Intertek Specifications are subject to change without notice. ©2023 Mitsubishi Electric Trans,HVAC US LLC.All rights reserved. Job Name: System Reference: Date: _ GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control • Dual Barrier Coating applied to the heat exchanger,vanes and fan to prevent hydrophilic and hydrophobic dirt build-up • Optional Microparticle Filter designed to capture PM2.5 �mrr The outdoor unit powers the indoor unit,and should a power outage occur, the system is automatically restarted when power returns • Quiet operation • Smart Set:recalls a preferred preset temperature setting at the touch of a button • Built-in backup/auxiliary heater control available • Multiple fan speed options:Quiet,Low,Medium,High,Super-high,Auto • Multiple control options available: o Back-lit screen handheld remote controller(provided with the unit) o kumo cloud®smart device app for remote access o Third-party interface options o Wired or wireless controllers Specifications System Unit Type MSZ-GS12NA Cooling Capacity'' BTU/H 12,000 Heating Capacity2•' BTU/H 14,400 Voltage,Phase,Frequency 208/230,1,60 Guaranteed Voltage Range VAC 187-253 Electrical Voltage:Indoor-Outdoor,S1-S2 VAC 208/230 Voltage:Indoor-Outdoor,S2-S3 V DC 24 Short-circuit Current Rating[SCCR] kA 5 MCA A 1.0 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 30 Airflow Rate at Cooling,Dry CFM 134-160-222-307-381 Airflow Rate at Cooling,Wet CFM 121-144-200-276-343 Airflow Rate at Heating,Dry CFM 134-160-222-307-390 Sound Pressure Level[Cooling] dB[A] 19-22-30-37-45 Indoor Unit Sound Pressure Level[Heating] dB[A] 19-22-30-37-43 Drain Pipe Size In.[mm] 5/8[15.88] Coating on Heat Exchanger Dual Barrier Coating External Finish Color Munsell 1.OY 9.2/0.2 Unit Dimensions W X D X H:In.[mm] 31-7/16 x 9-1/8 x 11-5/8[798 x 232 x 2951 Package Dimensions W x D x H:In.[mm] 33-1/2 x 12 x 14[850 x 300 x 350] Unit Weight Lbs.[kg] 23[10.4] Package Weight Lbs.[kg] 26[11.5] Refrigerant Type R410A Gas Pipe Size O.D.[Flared] In.[mm] 3/8[9.52] Piping Liquid Pipe Size O.D.[Flared] In.[mm] 1/4[6.35] NOTES: Conditions 'Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 IDS,75 WB 2Heating at 47°F(Indoor//Outdoor) °F 70 DB,60 WB//47 DB,43 WB 'Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit.For reference to connected capacity charts,please refer Multi-zone Outdoor Unit Operational Performance. Specifications are subject to change without notice. ©2023 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. INDOOR UNIT ACCESSORIES: BACnet®and Modbus®Interface PAC-UKPRC001-CN-1 CN24 Relay Kit CN24RELAY-KIT-CM3 IT Extender PAC-WHS011E-E kumo station®for kumo cloud® PAC-WHS01 HC-E Control Interface System Control Interface MAC-3341F-E Thermostat Interface PAC-US444CN-1 Thermostat Interface PAC-US445CN-1 USNAP Adapter PAC-WHS01 UP-E Wireless Interface for kumo cloud® PAC-USWHS002-WF-2 Remote Sensor Wired Remote Sensor M21 EAA307 Wireless temperature and humitity sensor for kumo cloud® PAC-USWHS003-TH-1 Deluxe Wired MA Remote Controllert PAR40MAAU Wired Remote Controller Simple Ductless Wired Remote Controller PAC-SDW01 RC-1 Simple MA Remote Controllert PAC-YT53CRAU-J Touch MA Controllert PAR-CT01 MAU-SB kumo touch'RedLINK'Wireless Controller MHK2 Wireless Remote Controller Lockdown bracket for remote controller RCMKPICB Blue Diamond(Advanced)Mini Condensate Pump w/Reservoir&Sensor(208/230V)[recommended] X87-721 Blue Diamond(MegaBlue Advanced)Condensate Pump w/Reservoir&Sensor X87-835 Blue Diamond Alarm Extension Cable—6.5 Ft. C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps C21-014 Blue Diamond Sensor Extension Cable—15 Ft. C13-103 Condensate Drain Pan Level Sensor/Control SS610E Fascia Kit for MicroBlue Pump,mounts the MicroBlue and sensor directly beneath indoor unit T18-016 Refco Condensate Pump(100-240 VAC) GOBI-11 Refco Condensate Pump(100-240 VAC)up to 120,000 BTU/H COMBI Sauermann Condensate Pump S130-230 Disconnect Switch (30A/600V/UL)[fits 2"X 4"utility box]-Black TAZ-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White TAZ-MS303W Filter Anti-allergy Enzyme Filter MAC408FT-E Microparticle(PM2.5)Filter MAC-EMF515FT-E NOTES: tRequires MAC-3341F-E "M-Series EZ FIT®Recessed Ceiling Cassette,Floor-mount and Wall-mount Allows indoor units to connect to an MA Controller: Deluxe MA Remote Controller Simple MA Controller Touch MA Controller Specifications are subject to change without notice. ©2023 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. INDOOR UNIT DIMENSIONS: Unit: inch 7/16xl Oblong hole 1/16xl3/I6 Oblong hole Installation late 3-1/8 8 7/8 8 7/8 3 1/8 31-7/16 30-15/16 1/4 0 6-I/8 6-I/8 2-3/8 13-5/16 13-9/16 2-1/8 9-1/8 Ai r i n al I hole m3 3/16 Indoor unit l� �J Installation Plate Pi in 1-3/4 1-15/16 24-3/8 �5-I5/8 4 3/16�= Drain hose 2-3/8m� — ; � � A I f 0 U t oM Insulation o1-9/16 10.1) c Liquid line o1/4 19-11/16(Flared connection o1/4) 2-3/I6 15/16 a Gas line o3/816-15/16 -3/1 6 (Flared connection:o3/8(GS06/09/12NA),o1/2(GS15NA)) Wireless remote Drain hose Insulation o1-1/8 O.D Connected part 05/8 O.D controller 1340 Satellite Boulevard Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com ETA�s FORM#MSZ-GS12NA-U1-202304 Intertek Specifications are subject to change without notice. ©2023 Mitsubishi Electric Trans,HVAC US LLC.All rights reserved. • MULTI-ZONE INVERTER HEAT-PUMP SYSTEM ­11­!�ECTFIU.S. Job Name: System Reference: Date: ® o MITSUBISHI �• a M_ELECTRIC 0 IIIIIIII��I �IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII i�, a MF � Illlllllllllllllllllllllllllllllllllllllllllllllli � 'IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII' ''��IIIIIIIIIIIIIIIIIiI lllllll llllllllll�l'' 9 FEATURES • Variable speed INVERTER-driven compressor • Optional base pan heater • Quiet outdoor unit operation as low as 52 dB(A) • High-pressure protection • Compressor thermal protection • Compressor overcurrent detection • Fan motor overheating/voltage protection • Blue Fin anti-corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life o Rated for 2,000 hours spraying time per ASTM B117 Standard Specifications are subject to change without notice. ©2023 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: • ' 1 I Maximum Capacity BTU/H 28,400 H 28,400 H 28,400 28,400 H 28,400 Cooling' Rated Capacity BTU/H 28,400 H 27,900//27,400 27,900 H 27,400 (Non-Ducted//Mix(Low-static)//Ducted Minimum Capacity BTU/H 11,600 H 11,300 H 11,000 11,900 H 12,200 (Low-static)I Mix(High-static)H Ducted Maximum Power Input W 4,040//4,000 H 3,960 4,045 H 4,050 (High-static)) Rated Power Input W 2,670//2,755 H 2,840 2,762//2,854 Power Factor(208V,230V) % 99.0,99.0 H 99.0,99.0 H 99.0,99.0 1 99.0,99.0 H 99.0,99.0 Maximum Capacity BTU/H 36,000//36,000 H 36,000 36,000//36,000 Heating at 47°F Rated Capacity BTU/H 28,600 H 28,100//27,600 28,100 H 27,600 (Non-Ducted//Mix(Low-static)//Ducted Minimum Capacity BTU/H 18,100 H 18,300 H 18,500 117,150 H 16,200 (Low-static)I Mix(High-static)H Ducted Maximum Power Input W 3,700 H 3,900 H 4,100 3,900 H 4,100 (High-static)) Rated Power Input W 2,149 H 2,185 H 2,220 2,198 H 2,247 Power Factor(208V,230V) % 99.0,99.0 H 99.0,99.0 H 99.0,99.0 1 99.0,99.0 H 99.0,99.0 Heating at 17°F' Maximum Capacity BTU/H 21,000 H 21,000 H 21,000121,000//21,000 (Non-Ducted H Mix(Low-static)H Ducted Rated Capacity BTU/H 18,600 H 18,200 H 17,800 1 18,200 H 17,800 (Low-static)I Mix(High-static)//Ducted Maximum Power Input W 2,860//2,910//2,960 12,910 H 2,960 (High-static)) Rated Power Input W 1,820 H 1,860 H 1,900 11,876 H 1,932 Heating at 5°F4 Maximum Capacity BTU/H 19,800 H 19,800 H 19,800 1 19,800//19,800 (Non-Ducted//Mix(Low-static)//Ducted (Low-static)I Mix(High-static)H Ducted Maximum Power Input W 3,100 H 3,205 H 3,310 13,205 H 3,310 (High-static)) SEER2 19.0 H 17.6 H 16.2 117.6 H 16.2 EER21 10.6 H 10.1 H 9.6 10.1H9.6 Efficiency HSPF2(IV) 10.0 H 9.4 H 8.8 9.4 H 8.8 (Non-Ducted H Mix(Low-static)//Ducted COP at 47°F' (Low-static)I Mix(High-static)H Ducted 3.9//3.75//3.6 3.75//3.6 (High-static)) COP at 17°F at Maximum Capacity3 2.15 H 2.11 H 2.07 2.12 H 2.08 COP at 5°F at Maximum Capacity4 1.87 H 1.81 H 1.75 1 1.81 H 1.75 ENERGY STAR®Certified No H No H No No H No Electrical Power Requirements Voltage,Phase, 208/230,1,60 Frequency Guaranteed Voltage Range VAC 187-253 Voltage:Indoor-Outdoor,S1-S2 VAC 208/230 Voltage:Indoor-Outdoor,S2-S3 V DC 24 Electrical Short-circuit Current Rating(SCCR) kA 5 Recommended Fuse/Breaker Size A 25 Recommended Wire Size(Indoor-Outdoor) AWG 14 Minimum Circuit Ampacity A 22.1 Maximum Overcurrent Protection A 25 Fan Motor Full Load Amperage A 2.43 Airflow Rate(Cooling/Heating) CFM 2,133/2,243 Refrigerant Control LEV Defrost Method Reverse Cycle Heat Exchanger Type Plate Fin Coil Heat Exchanger Coating Blue Fin Coating Sound Pressure Level,Cooling' dB(A) 52 Sound Pressure Level,Heating2 dB(A) 56 Compressor Type DC INVERTER-driven Twin Rotary Compressor Model SNB220FCGMC Compressor Rated Load Amps A 12 Outdoor unit Compressor Locked Rotor Amps A 13.7 Compressor Oil Type H Charge oz. FV50S H 23.7 Base Pan Heater Optional W:In.[mm] 37-13/32[950] Unit Dimensions D:In.[mm] 13[330] H:In.[mm] 31-11/32[796] W:In.[mm] 41-11132[1,0501 Package Dimensions D:In.[mm] 17-5/16[440] H:In.[mm] 38-31/32[990] Unit Weight Lbs.[kg] 142[64.3] Package Weight Lbs.[kg] 174[78.9] Cooling Intake Air Temp(Maximum/Minimum'") °FDB 115/14 Outdoor unit operating temperature Cooling Thermal Lock-out/Re-start Temperatures °FDB 10.4/14 range Heating Intake Air Temp(Maximum/Minimum) °FWB 65/5 Heating Thermal Lock-out/Re-start Temperatures °FDB 1.4/5 NOTES: AHRI Rated Conditions 'Cooling(Indoor H Outdoor) °F 80 DB,67 WB//95 DB,75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F(Indoor//Outdoor) °F 70 DB,60 WB//47 DB,43 WB 3Heating at 17°F(Indoor//Outdoor) °F 70 DB,60 WB//17 DB,15 WB Conditions 'Heating at 5°F(Indoor//Outdoor) °F 70 DB,60 WB//5 DB,4 WB `Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. `"5°F DB-115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected,please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%,the outdoor unit cannot provide more than 100%of the rated capacity.Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Low,mid and high external static pressure tests conducted at 0.1,0.3 and 0.5 in.w.g.respectively,according toAHRI 210/240.The external static pressures utilized have no bearing on the capabilities of the indoor unit;please refer to the indoor unit manual to select the correct external static pressure setting for the application. Specifications are subject to change without notice. ©2023 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: • ' 1 I Type R410A Pre-Charged Refrigerant Amount Lbs,oz 6.0,13.0 Refrigerant Maximum Pre-Charged Piping Length Ft.[m] 98.0[30.0] Additional Refrigerant Charge Per Additional Piping Length oz./Ft.[g/m] 0.216[20] Maximum Number of Connected IDU 3 Indoor unit connection Minimum Number of Connected IDU 2 Minimum connected capacity BTU/H 12,000 Maximum connected capacity BTU/H 36,000 Liquid Pipe Size O.D.(Flared) In.[mm] A,B,C:1/4[A,B,C:6.35] Gas Pipe Size O.D.(Flared) In.[mm] A:1/2;B,C:3/8[A:12.72:B,C:9.52] Total Piping Length Ft.[m] 230[70] Piping Maximum Height Difference,ODU above IDU Ft.[m] 49[15] Maximum Height Difference,ODU below IDU Ft.[m] 49[15] Farthest Piping Length from ODU to IDU Ft.[m] 82[25] Maximum Number of Bends for IDU 70 NOTES: AHRI Rated Conditions 'Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB (Rated data is determined at a fixed compressor speed) 21-leating at 47°F(Indoor//Outdoor) °F 70 DB,60 WB//47 DB,43 WB 'Heating at 17°F(Indoor//Outdoor) °F 70 DB,60 WB//17 DB,15 WB Conditions 41-leating at 5°F(Indoor//Outdoor) °F 70 DB,60 WB//5 DB,4 WB 'Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. "5°F DB-1157 DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected,please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%,the outdoor unit cannot provide more than 100%of the rated capacity.Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Low,mid and high external static pressure tests conducted at 0.1,0.3 and 0.5 in.w.g.respectively,according toAHRI 210/240.The external static pressures utilized have no bearing on the capabilities of the indoor unit;please refer to the indoor unit manual to select the correct external static pressure setting for the application. Specifications are subject to change without notice. ©2023 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. OUTDOOR • ACCESSORIES: • ' 1 I Air Outlet Guide Air Outlet Guide(1 Piece) PAC-SH96SG-E Refrigeration Ball Valve-1/2" BV12FFS12 Ball Valve Refrigeration Ball Valve-1/4" BV14FFSI2 Refrigeration Ball Valve-3/8" BV38FFSI2 Refrigeration Ball Valve-5/8" BV58FFSI2 Control Wire M-Net Control Wire,1,000'Roll(16-AWG,Standard,Twisted Pair,Shielded,Jacketed-Plenum rated) CW162S-1000 M-Net Control Wire,250'Roll(16-AWG,Standard,Twisted Pair,Shielded,Jacketed-Plenum rated) CW162S-250 Drain Socket Drain Socket PAC-SG60DS-E Hail Guards Hail Guard HG-A9 M-NET Converter M-NET Converter PAC-IF01 MNT-E 14 Gauge,4 wire MiniSplit Cable-250 ft.roll S144-250 14 Gauge,4 wire MiniSplit Cable-250 ft.roll SW144-250 14 Gauge,4 wire MiniSplit Cable-50 ft.roll S144-50 Mini-Split Wire 14 Gauge,4 wire MiniSplit Cable-50 ft.roll SW144-50 16 Gauge,4 wire MiniSplit Cable-250 ft.roll S164-250 16 Gauge,4 wire MiniSplit Cable-250 ft.roll SW164-250 16 Gauge,4 wire MiniSplit Cable-50 ft.roll S164-50 16 Gauge,4 wire MiniSplit Cable-50 ft.roll SW164-50 Mounting Pad Condensing Unit Mounting Pad:16"x 36"x 3" ULTRILITEI Outdoor Unit 3-1/4 inch Mounting Base(Pair)-Plastic DSD-400P Adaptor:1/2"x 3/8" MAC-A455JP-E Port Adaptor Adaptor:1/2"x 5/8" MAC-A456JP-E Adaptor:3/8"x 1/2" MAC-A454JP-E Adaptor:3/8"x 5/8" PAC-SG76RJ-E 18"Single Fan Stand QSMS1801M 24"Single Fan Stand QSMS2401M Stand Condenser Wall Bracket QSWB2000M-1 Condenser Wall Bracket-Stainless Steel Finish QSWBSS Outdoor Unit Stand—12"High QSMS1201M Specifications are subject to change without notice. ©2023 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. OUTDOOR UNIT DIMENSIONS: MXZ-3C30NA4 Unit: inch (mm) 6-7/8' 23-5/8" Rear Air Intake 2-13/16' 9-1/16 4-19/32' 2-1/32° 3-1/16' 2-U Shaped Notched Hole 13/32' (Foundation Bolt M10) 3-3/32' zo in N M Side Air Intake* ad rn 6-01-5/16'Drain Hole m r b oaiscnar9e 13/32" 2-(15/32'x1-13/32') Oval Hale 1-1/32' 2-07/8°knockout hole (Foundation Bolt 110) 1-1/2' (Connectin wire hole) 1-5/8' 37-13/32" 31/32' 13, 19/32' 3-07/8°punched hole IConneding wire hole) Handle N m �� m NEW Handle O Handle Handle N O® rn Air Intake �® ua }unit c GAS LIO 1/8(06.52)FL RE m O® GAa}Unit g 6A5 3/8'(09.52)FLARE O® f 1 GAS}Unit A— GAAS 1/2'Im 2.7)FLARE v ? 1-11/32' 14-7/32" 1.FREE SPACE E E E O 3-15/16" or more i p 0 8 777TT 3-15/16" or more 13-25/32" or more 2.SERVICE SPACE o E `o E Conduit plates a Conduit connector 3-15/16" or more —„ SERVICE SPACE 13-25/32' ❑r more 13-25/32' or more Lock nut 1340 Satellite Boulevard Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com ETV us FORM#MXZ-3C30NA4-202311 Intertek Specifications are subject to change without notice. ©2023 Mitsubishi Electric Tirane HVAC US LLC.All rights reserved.