Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6206 188th Ave Ne_BLD5609_2025
i Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 591h Avenue NE • Arlington,WA 98223 • Phone (360)403-3551 Permit Number: BLD5609 Permit Type: Commercial Mechanical Address/Parcel: 6206 188th Ave Ne Completed (Month/Year): EXPIRED December 2024 Land Use ❑ Notice of Decision ❑ Bonding or Assignment of Funds ❑ Staff Report o Confidential Documents. Contact the ❑ Application City to obtain. ❑ Narrative ❑ Letters and Project Documents ❑ Legal Description ❑ Other: ❑ Vicinity Map ❑ Site Plan Civil ❑ Landscape Plan ❑ Issued Permit ❑ Complete Streets Checklist ❑ Application ❑ Traffic Impact Analysis ❑ Other Applications ❑ Snohomish County Traffic Mitigation Offer ❑ Construction Calculation Worksheet ❑ WSDOT Traffic Offer Form ❑ Approved Plans ❑ Tree Survey ❑ Review Comment Form ❑ Stormwater Drainage Report ❑ Letters and Project Documents ❑ Geotech Report ❑ Other Agency Permits ❑ Critical Area Evaluation Form ❑ Reports: ❑ SEPA Checklist o Drainage Report Pg: ❑ Public Notice Material o Stormwater Pg: ❑ Noticing and Related Documents o Geotech Pg: ❑ Water/Sewer Availability Certificate o All Other Reports ❑ Unanticipated Discovery Plan Form ❑ SEPA and Noticing Materials ❑ Aerial Photo of Site ❑ Inspections ❑ Proposed Building Materials ❑ As-Builts ❑ Lighting Plans and Lighting Cut Sheets ❑ Other: ❑ Color Elevations ❑ Design Matrix Building ❑ Plat Map ❑✓ Issued Permit ❑ Title Report ❑✓ Application ❑ Lot Closures ❑ Additional Applications ❑ Preliminary Civil Plans ❑✓ Approved Plans ❑ Archaeological Survey ❑ Site Plan o Confidential Documents. Contact the ❑ Letters and Project Documents City to obtain. ❑ Calculations ❑ Topography(Existing Conditions) ❑✓ Project Specification Manuals ❑ CC&R's ❑ Reports ❑ Deeds/Easements/Conveyances ❑ Certificate of Occupancy /Dedications ❑ Inspections ❑ Developer's Agreement ❑ Other: ❑ Recorded Copies Page 1 of 1 CITY OF ARLINGTON • 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 6206 188TH AVE NE Permit#:5609 Parcel#:31052200100900 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:24kW Generator Installation on east side of laundry room building Valuation:3000.00 and connection to existing natural gas line. OWNER APPLICANT CONTRACTOR OTTO INVESTMENTS 1 LLC Arlington Electric,Inc. Arlington Electric,Inc 12470 NE 162ND ST 13310 240th St NE 13310 240th St NE WOODINVILLE,WA 98072 Arlington,WA 98223 Arlington,WA 98223 360-403-0515 360-403-0515 LIC:ARLINEI833QN EXP: 11/13/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL MECHANICAL CODE YEAR: 2018 STORIES: i CONST.TYPE: lA DWELLING UNITS: OCC GROUP: R-1;Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE - OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. �'1 a7 � 1 10/06/2023 Applicant Signature Date Building Official Date CONDITIONS Adhere to approved plans.Call for inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 1 010912 02 3 Web Only-Mechanical Commercial Plan Review $80.33 10/09/2023 Credit Card Service $2.41 10/09/2023 Gas Piping/Units $15.00 10/09/2023 Mechanical Misc. $15.00 Total Due: $112.74 Total Payment: $112.74 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail COMMERCIAL MECHANICAL APPLICATION Community&Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 •Phone(360)403-3551 This application is for new, addition,altered or replaced mechanical installation and new or altered gas piping and mustbe accompanied by ELECTRONIC CONSTRUCTION DRAWINGS and CUT SHEETS and/or information outlined in the MECHANICAL SUBMITTAL REQUIREMENTS,if applicable. Type of Permit: ❑ New Installation ❑ Addition ❑ Alteration ❑ Replaced © Gas Piping Type I and Type II Hood Systems required submittal of the Commercial Mechanical Addenda Property Address: 6206 188th St NE Project Valuation: Lot#: Parcel ID No.: 31052200100900 Preferred Contact: ❑ Owner O Contractor Project Description: 24kW Generator Installation and connection to existing natural gas line. Owner Name: Otto Investments LLC Office No.: Email Address: Cell No.: Mailing Address: 12470 NE 162ND ST City: Woodinville State: WA Zip:98072 i :98072 Contractor Name: Arlington Electric, Inc. office No.: 360-403-0515 Email Address: arlingtonelectric@msn.com Cell No.: Mailing Address: 13310 240th St NE City: Arlington State: WA Zip: 98223 L&I Contractor License Number: ARLINE1822BJ Expiration Date: 01/11/24 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured per IFGS,Section 415 • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of each appliance Gas Piping Specification and complete Schematic PAGE 3 ❑ Not Applicable ❑ CSST ❑ Brass O Other Proposed Piping Material: 0 Black Steel ❑ Galvanized Steel Proposed Piping Size: ❑ Y2" ❑ 5/8" O 3/4 ❑ 1" ❑ 1Y2" ❑ 2" Inlet Pressure: 7-14" we Pressure Drop: NA Specific Gravity: NA REV03.2022 Page 1 of 3 MECHANICAL PERMIT FEES (per unit Type of Fixture No.of Units Cost per Unit Subtotal Additional Plan Review fees x $75.00 = $ Air Cond.Unit<_100Btu h x $15.00 = $ Air Cond.Unit>100Btu h x $25.00 = $ Air Cond.Unit>50OBtu/hp x $50.00 = $ Air Handling Units x $ 15.00 = $ Base Mechanical Fee $25.00 $25.00 Boiler<100Btu >3h x $15.00 = $ Boiler>1 million Btu/h<50hp x $25.00 = $ Boiler>1.5 million Btu/h<50hp x $50.00 -- $ Boiler>100Btu 3-15h x $15.00 = $ Boiler>500Btu 15-301 x $25.00 = $ Commercial Hoods-Type I x $25.00 = $ Commercial Hoods-Type 11 x $50.00 = $ Diffusers x $15.00 = $ Dryer Ducting x $15.00 = $ Ductwork(drawings required) x $25.00 = $ Evaporative Coolers x $ 15.00 = $ Exhaust Ventilation Fans x $ 15.00 = $ Fireplace/Insert/Stove x $ 15.00 = $ Forced Air Heat<_100 Btu h x $ 15.00 = $ Forced Air Heat>100 Btu h x $ 25.00 = $ Gas Clothes Dryer x $ 15.00 = $ Gas Fired AC s100 Btu h x $ 15.00 = $ Gas Fired AC>100 Btu h x $25.00 = $ Gas Fired AC>500 Btu h x $50.00 = $ Gas Pipings 5 units 1 x $15.00 = $15 Gas Piping>5 units (plus<5 units x $2.00 = $ Heat Exchangers x $15.00 = $ Heat Pump-Condensing Unit x $25.00 = $ Hot Water Heat Coils x $15.00 = $ Miscellaneous Appliance-regulated by 1 x $ 15.00 _ $15 mechanical code not otherwise specified Pkg.Units s100btu x $25.00 = $ Pkg.Units>100btu x $ 50.00 = $ Range/Cook top-Gas Fired x $ 15.00 = $ Refrigeration Unit<_100Btu h x $ 15.00 = $ Refrigeration Unit>100Btu h x $25.00 = $ Refrigeration Unit>500Btu h x $50.00 = $ Re-inspection fee(all) x $75.00 = $ Unit Heaters s 100 Btu h x $15.00 = $ Unit Heaters>100 Btu h x $25.00 = $ VAV Boxes(Variable Air Volume,part of air x $ 10.00 $ conditioning system) Wall Heaters-Gas Fired x $25.00 = $ Water Heater-Gas Fired x $25.00 = $ Permit Fee $ Table 4-8; Plan Review Fee $ Processing/Technology Fee $25.00 Total $80.00 REV2.2020 Page 2 of 3 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE ❑✓ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE:Any interior pressure regulators must be indicated f\j COGS �11f;�G./ t f V� I hereby certify that am the❑owner,[]Applicant, ❑Contractor,and authorized to sign this application andthat the above information is correct and construction on,and the occupa cy and the use of the above-described property will be in accordance with the laws,rules and regulation of th fate of Washington, he City of Arlington.A final inspection and approval shall be obtained when complete. e�( iQl , a Signature Print Name Date REV2.2020 SAVE PRINT Page 3 of i c ��f� '�{�ey U�"�. �'����� '�' ,�14:.. am�. t ,_I 1 ` �;i J ��•�` ��� l�p� �9Ft.�ffl !�S� 1 I' � i i I �i(I I I'li ':: �� �}! � � I f - Mk 171 e a ► JJ �rl t t" r11T 3� 11§ ' � r a�� ����•� � III }u l a � ���� U; is -r r I } 1 r s F aftri - i T au - - it _ . L , ,v _ - - �i GAS CANX. PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE ® SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE:Any interior pressure regulators must be indicated CITY OF ARLIN TON BUILDING DEPARTM NT APPROVED DATE / 5IZ BY NO CHANGES AUTHJBYHE D UNLESS APPROVED BUILDING INSPE V4 I hereby certify that Iam the0owner,[]Applicant, QContractor,and authorized to sign this application and that the above information is correct and construction on,and the occupy ry and the use of the above-described property will be in accordance with the laws,rules and regulation of th tote of Washingro5woae City of Arlington,A final inspection and approval shall be obtained when complete. .4 l 71_-I+D., Signature Print Name Date REV2.2020 SAVE PRINT Page 3 of 3 CITY OF A,LINGT N E RAC® BUILDING DEPARTMENT APPROV�® UARDIAN® SERIES 20/22/24 kW DATE 3 BY idt ntial Standby Generators NO CHANGES AUTHORIZED UNLESS APPROVED BY THE Air-Cooled Gas Engine BUILDING INSPECTOR MEM-L r , Standby Power Rating INCLUDES: 0007038-I,G007039-1,3007038-3,G007039-3(Aluminum-Bisque)-20!M 60 H2: 0 True Power'" Electrical Technology G007042-2.0007043-2,G007042-3 G007043-3(Alun iinum-Bisquc)-22 MAI 60 Hz 3007209-0.G007210-0(Aluminum-Bisque)-24 kVv 60 H� • Two-line multilingual digital LCD Evolution'" controller (English/Spanish/French/Portuguese) • 200 amp service rated transfer switch available • Electronic governor _ • Standard Wi-Fig connectivity • System status&maintenance interval LED indicators • Sound attenuated enclosure • Flexible fuel line connector • Natural gas or LP gas operation GENERAC' • 5 Year limited warranty • Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in(457 mm)to a structure.` — `Must be located away from doors,windows,and fresh air intakes and in accordance with local codes. or C �L US Q�I hflps./lassels.swri.orgilibrary/DirecroryOttisledProducfs/ C(S `X a k" FTEST Cons(ruclionlnduslry/973_DoC_204_13204-01-01_Rev9pdf °S LISTED Note CETL or CUL certilication only applies to unbundled units and units packaged with limited circuit switches.Units packaged with the Smart Switch are ETL or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN &RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1% O TRUE POWER'" ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG11-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK°CONNECTIVITY:FREE with select Guardian Series Home standby O PWRVIEWT' TRANSFER SWITCH: The Generac PWRview Automatic Transfer generators, Mobile Link Wi-Fi allows users to monitor generator status from any- Switch integrates the PWRview energy monitor to provide real-time energy con- where in the world using a smartphone,tablet,or PC.Easily access information such sumption data that can help lower a home's electricity bill. Using a convenient as the current operating status and maintenance alerts. Users can connect an mobile app,homeowners can access energy usage and alert information while under account to an authorized service dealer for fast,friendly,and proactive service.With utility power or generator power.The PWRview energy monitor is a simple to use and Mobile Link,users are taken care of before the next power outage. low cost tool which helps save money over the life of the generator.Included with model G007210-0. Received l' GENERAC w GENERAC' PROMISE ® �®' ~`M .. PWR GENERAC' 20/22/24 kW Features and Benefits _ Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,lightweight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. PWRview Transfer Switch(if applicable) • PWRview energy monitor Energy usage at-a-glance. • Ability to view real-time energy consumption data Better understand the home's energy profile. • PWRview mobile app Access daily energy intelligence and insights. Evolution'" Controls • AUTO/MANUAUOFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. GENERACg 20/22/24 kW Features and Benefits Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. Installation System ' 1 • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(Wi-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAC� 20/22/24 kW Specifications Generator Model G007038-1 G007042-2 G007038-3 G007042-3 G007209-0 G007039-1 G007043-2 G007039-3 G007043-3 G007210-0 (20 kW) (22 kW) (20 kW) (22 kW) (24 kW) Rated maximum continuous power capacity(LP) 20,000 Wafts' 22.000 Wafts' 20,000 Watts' 22,000 Watts' 24,000 Watts' Rated maximum continuous power capacity(NG) 18,000 Watts' 19,500 Watts' 18,000 Watts' 19,500 Watts' 21,000 Watts' Rated voltage 240 Rated maximum continuous load current—240 volts(LP/NG) 83.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3 100/87.5 ' of ' Total Harmonic Dislortion Less than 5% Main line circuit breaker 90 amp 100 amp 90 amp 100 amp 100 amp Phase 1 Number of rotor poles 2 Rated AC frequency 60 Hz Power factor 1.0 Battery requirement(not included) 12 Volts,Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum Unit weight(lb/kg) 448/203 466/211 436/198 445/202 455/206 Dimensions(L x W x H)in/cm 48 x 25 x 29/121.9 x 63.5 x73.7 Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load"' 67 67 67 67 67 Sound output in dB(A)al 23 It(7 m)with generator in Quiet-Test'"low-speed exercise mode' 55 57 55 57 57 Exercise duration 5 min Engine Engine type GENERAC G-Farce 1000 Series Number of cylinders 2 Displacement 999 cc Cylinder block Aluminum w/cast iron sleeve Valve arrangement Overhead valve Ignition system Solid-stale w/magneto Governor system Electronic Compression ratio 9.5:1 Starter 12 VDC Oil capacity including filter Approx.1.9 qt/18 L Operating rpm 3,600 Fuel consumption Natural gas fl3/h1 2 Load 204 5 78 228(6.46) 164(4.64) 203(5 75) Full Load 301(8.52) 327(9.26) 287(8.13) 306(8 66) Liquid propane tta/hr(gal/hr)[Uhr] 112 Load 87(2.37)[8.99] 92(2.53)[9.57] 86(2.36)[8.95] 92(2.53)[9.57] Full Load 130(3.56)[13,481 142(3.90)[14,77] 136(3.74)[14.151 142(3.90)[14.77] Note:Fuel pipe must be sited for lull load.Required luel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49--2.99 kPa)for LP gas For BTU content multiply It3Au x 2500(LP)or 1131hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m'AV x 37.26(NG). Controls Two-line plain text mullilingual LCD Simple user interface for ease of operation. Mode buttons:AUTO Automatic start on utility failure.Weekly,Bi-weekly,or Monthly selectable exerciser. MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place OFF Stops unit.Power is removed.Control and charger still operate. Ready to Run/Maintenance messages Standard Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) Utility Voltage Loss/Return to Utility adjustable(brownout setting) From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error warning Standard Run/Alarm/Maintenance logs 50 events each Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration), Starter lock-out Starter cannot re-engage until 5 sec after engine has stopped. Smarl Battery Charger Standard Charger FaulUMissing AC warning Standard Low Battery/Battery Problem Protection and Battery Condition indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurreni Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal FaulVlncorrecl Wiring protection Standard Common external fault capability Standard Field upgradable firmware Standard "Sound levels are taken from the Ifonl of the generator.Sound levels taken from other sides of one generator may be higher depending on installation parameters Rating definifions-Standby.Applicable for supplying emergency power for the duration of the utility power outage-No overload capability is available for this rating_(All ratings in accordance with BS5514,IS03046 and OIN6271).'Maximum kilovolt amps and current ate subject to and limited by such lawns as fuel BTUAnegajoule content,ambient temperature.altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%tor each 1.000 II(304.8 m)above sea level,and also will decrease apptoximately 1%for each 10'F(6'C)above 60 F(16"C). GENE-RAC' 20/22/24 kW Switch Options Service Rated Automatic Transfer Switch Features Model 13007039-1,G007039-3(20 kW) • Intelligently manages up to four air conditioner loads with no additional hardware. 13007043-2,6007043-3(22 kW) _ No.of poles 2 • Up to eight additional large(240 VAC)loads can be managed when used in conjunction Current rating(amps) 200 with Smart Management Modules(SMMs). Voltage rating(VAC) 120/240,10 • Electrically operated,mechanically-held contacts for fast,clean connections. Utility voltage monitor(fixed)' • Rated for all classes of load,100%equipment rated,both inductive and resistive. -Pick-up 80% P -Dropout 65% • 2-pole,250 VAC contactors. Return to Utility' Approx.13 sec r • Service equipment rated,dual coil design. Exercises bi-weekly for 5 minutes" Standard ETL or UL listed Standard • Rated for both aluminum and copper conductors. Enclosure type NEMA/UL 3R • Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit breaker protected 22,000 • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Lug range 250 MCM-#6 "Function of Evolution controller Dimensions Exercise can be set to weekly,bi-weekly,or monthly wr 200 Amps 120/240,1e Open Transition Service Rated i Height Width Depth H1 H2 W1 W2 in 26.8 30.1 10.5 13.5 6.9 cm 67.95 1 76.43 26.67 34.18 17.5 j H2 "' Wire Ranges ' Conductor Lug Neutral Lug Ground Lug 250 MCM-#6 1 350 MCM-#6 2/0-#14 L oPPM PWRview Automatic Transfer Switch Features Model G007210-0(24 kW) • Integrated PWRview monitor provides real-time energy usage data through PWRview app. No.of poles 2 Current rating(amps) 200 • Intelligently manages up to four air conditioner loads with no additional hardware. Voltage rating(VAC) 120/240,10 • Up to eight additional large(240 VAC)loads can be managed when used in conjunction Utility voltage monitor(fixed)" with Smart Management Modules(SMMs). -Pick-up 80% -Dropout 65% • Electrically operated,mechanically-held contacts for fast,clean connections. Return to Utility' Approx.13 sec • Rated for all classes of load,100%equipment rated,both inductive and resistive. Exercises bi-weekly for 5 minutes' Standard • 2-pole,250 VAC contactors. ETL or UL listed Standard Enclosure type NEMA • Service equipment rated,dual coil design. Circuit breaker protected 22,000 • Rated for both aluminum and copper conductors. Lug range 250 MCM-#6 • Main contacts are silver plated or silver alloy to resist welding and sticking. "Function of Evolution controller Exercise can be set to weekly,bi-weekly,or monthly • NEMA 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. vn • Heavy duty Generac Contactor is an ETL recognized device. Dimensions 200 Amps 120/240,1 e Open Transition Service Rated Height Width N2 I m H1 H2 W1 VY2 Depth i in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 Wire Ranges Conductor Lug I Neutral Lug Ground Lug 250 MCM-#6 1 350 MCM-#6 210-#14 GENERAC3 20/22/24 kW Available Accessories _ Model# Product Description G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generale offers the recommended 26R wet cell battery for use with all air-cooled standby product(excluding PowerPact°). G007101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0°F(-18°C).(Not nec- essary for use with AGM-style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0°F(-18°C). G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be Contact Kit needed.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured (Standard on 22/24 kW) appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). G007005-0 Wi-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the Monitor LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce (100 amp) the overall size and cost of the system. G007169-0-4G LTE Mobile Link`"'Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using G007170-0-Wi-Fi/ Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us- Ethernet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. G007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & UPCs Model UPC 637 9�^'^l [ale a�nl 1216 mm G007038-1 696471074185 175,m G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 727-2mm [2e 6 inI G007042-3 6964710742018 G007043-2 696471074215 7mill G007043-3 696471074215 0 0 G007209-0 696471071511 G007210-0 696471078220 64a mm 1232 mm [25.5,nl [46.5 ml LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual far exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES- GENERAC3 Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com 9)2020 Generac Power Syslems,Inc.All rights reserved.All specifications are subject to change without notice.Part No.A0000937814 Rev.B 07/30/2020