HomeMy WebLinkAbout5200 172nd St Ne Lot C Ste E_BLD5786_2025 i
Permit Packet Coversheet
Community and Economic Development
City of Arlington • 18204 591h Avenue NE • Arlington,WA 98223 • Phone (360)403-3551
Permit Number: BLD5786 Permit Type: Fire Alarm
Address/Parcel: 5200 172nd St Ne Lot C Ste E Completed (Month/Year): EXPIRED December 2024
Land Use
❑ Notice of Decision ❑ Bonding or Assignment of Funds
❑ Staff Report o Confidential Documents. Contact the
❑ Application City to obtain.
❑ Narrative ❑ Letters and Project Documents
❑ Legal Description ❑ Other:
❑ Vicinity Map
❑ Site Plan Civil
❑ Landscape Plan ❑ Issued Permit
❑ Complete Streets Checklist ❑ Application
❑ Traffic Impact Analysis ❑ Other Applications
❑ Snohomish County Traffic Mitigation Offer ❑ Construction Calculation Worksheet
❑ WSDOT Traffic Offer Form ❑ Approved Plans
❑ Tree Survey ❑ Review Comment Form
❑ Stormwater Drainage Report ❑ Letters and Project Documents
❑ Geotech Report ❑ Other Agency Permits
❑ Critical Area Evaluation Form ❑ Reports:
❑ SEPA Checklist o Drainage Report Pg:
❑ Public Notice Material o Stormwater Pg:
❑ Noticing and Related Documents o Geotech Pg:
❑ Water/Sewer Availability Certificate o All Other Reports
❑ Unanticipated Discovery Plan Form ❑ SEPA and Noticing Materials
❑ Aerial Photo of Site ❑ Inspections
❑ Proposed Building Materials ❑ As-Builts
❑ Lighting Plans and Lighting Cut Sheets ❑ Other:
❑ Color Elevations
❑ Design Matrix Building
❑ Plat Map ❑✓ Issued Permit
❑ Title Report ❑✓ Application
❑ Lot Closures ❑ Additional Applications
❑ Preliminary Civil Plans ❑✓ Approved Plans
❑ Archaeological Survey ❑ Site Plan
o Confidential Documents. Contact the ❑ Letters and Project Documents
City to obtain. ❑ Calculations
❑ Topography(Existing Conditions) ❑ Project Specification Manuals
❑ CC&R's ❑ Reports
❑ Deeds/Easements/Conveyances ❑ Certificate of Occupancy
/Dedications ❑ Inspections
❑ Developer's Agreement ❑ Other:
❑ Recorded Copies
Page 1 of 1
CITY OF ARLINGTON
18204 59th Avenue NE,Arlington,WA 98223
INSPECTIONS:360-403-3417-Permit Center:360-403-3551
- BUILDING PERMIT
5200 172ND ST NE LOT C STE.E Permit#:5786
Parcel#:31052700200203 PERMIT EXPIRES 180 DAYS AFTER
DATE OF ISSUANCE.
Scope of Work:Installation of a wireless communicator onto an existing fire alarm Valuation:6372.00
system.
OWNER APPLICANT CONTRACTOR
J AND B HOTEL PARTNERS,LLC Cascadia Electrical Solutions Cascadia Electrical Solutions LLC
17303 34TH PL W 1520 4th St 733 7th Ave Ste 211
LYNNWOOD,WA 98037 Marysville,WA,98270 Kirkland,WA 98033
3606402922 3606402922
LIC:603 497 631 EXP:04/30/2024
LIC:CASCAES856PN EXP:10/15/2025
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
LIC#: EXP: LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: FIRE ALARM CODE YEAR: 2018
STORIES: 2 CONST.TYPE: VB
DWELLING UNITS: OCC GROUP: R-2;Residential
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any
other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the
Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any
period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice
or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is
authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or
any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or
decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or
on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or
federal law,or any order,proclamation,guidance or decision of the Governor.
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK
AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE
STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND
ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN
MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.I13C110/IRC110.
SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on
your sales tax return form and coded City of Arlington#3101.
02/07/2024
Applicant Signature Date Building Official Date
- CONDITIONS ■
Approved job copy shall be onsite for inspections.Adhere to approved plans. Call for inspections.
The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property
owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or
community.The property owner shall be responsible for obtaining all necessary pennits and approvals from the relevant authorities
before commencing construction.The property owner shall ensure that the construction project complies with all applicable design
review requirements.
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE
PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,
MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
02/13/2024 Web Only-Fire System Plan Review $200.00
02/13/2024 Fire System Plan Review $126.42
02/13/2024 Credit Card Service $6.00
02/13/2024 Credit Card Service $3.79
02/13/2024 Processing/Technology $25.00
02/13/2024 FRCP/Transmitter-Replace $125.00
Total Due: $486.21
Total Payment: $486.21
Balance Due: $0.00
CALL FOR INSPECTIONS
Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
INSPECTION INFORMATION I Pass/Fail
i
FIRE ALARM PERMIT APPLICATION
• Community and Economic Development
City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551
Type of Permit: ❑ New Installation ✓❑ System Modification ❑ Phased Installation
5200 172nd St NE Arlington WA 98223
Property Address: Suite No.: NIA Project Valuation: 6372.00
Lot#: Parcel ID No.: 31052700200201 Preferred Contact: O Owner 0 Applicant
71 Contractor
Project Description:
Installation of an AES radio onto an existing fire alarm system.
Owner Name: Sunny Goutam LLC Phone No.:
Email Address: Cell No.:
Mailing Address: 5200 172nd St NE City: Arlington State: WA Zip: 98223
Applicant Name: Devin Dedman Phone No.: 360.640.2922
Email Address: info@cascadia-solutions.conl Cell No.:
Mailing Address: 1520 4th St City: Marysville State: WA Zip: 98270
Contractor Name: CasCadia Electrical Solutions LLC Phone No.: 425.493.3604
Email Address: info@CasCadia-solutions.com Cell No.:
Mailing Address: 1520 4th St city: Marysville State: WA Zip: 98270
L&I Contractor License Number: CASCAES856NP Expiration Date: 04/30/24
SUBMITTAL REQUIREMENTS: Provide Information on All Equipment to be Installed Prior to Installation
Submit electronic files of the follow:
❑ Complete and Scaled Plans
❑ Specification Sheets
❑ Wiring Diagrams (Point to Point Wiring)
❑ Electrical Plans,if applicable
NOTE: All Central Station Monitoring must be UL or FM listed.
FIRE ALARM SYSTEMS (105.7.3)
** DEVICES include separate individual portions of a Fire Alarm System such as: Initiating Devices,
Notification Appliances, Flow Switch, Supervisory Switches, Magnetic Door Hold-Open Devices, Remote
Annunciators, Pull Stations, Beam Detectors, and other such devices. (Each piece is one device)
PLAN REVIEW FEES -shall be paid at time of application submittal
Less than $5,000.00 = $100.00
$5,000.00 &over-based on project valuation
(Plan Review Fee is 65%of project valuation per Fee Calculation Table 4-1)
REV2022 Page 1 of 2
REINSPECTION / PHASED INSTALLATION INSPECTIONS
Submit Phasing Plan with Application - review and approval required
REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE
Reinspection/Phased Installation fee is charged per hour (1 hour minimum) $75.00
✓0 TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 72)
Number of Devices" Device Fee Subtotal
1to2 $ 75.00 = $
3 to 5 $125.00 = $
6 to 10 $175.00 = $
11 to 20 $225.00 = $
21 to 40 $300.00 = $
41 to 100 $375.00 = $
101 to 200 $475.00 = $
> 200 $500.00 plus$50.00 per 100 additional devices(round up)
Total Number of Devices = o $500.00 + $ _ $
FACP/TRANSMITTER Modification $125.00 = $ 125
PERMIT FEE SUBTOTAL $ 125
❑ NEW COMMERCIAL SYSTEM (NFPA 72)
Number of Devices" Device Fee Subtotal
1 to 100 $350.00 = $
101 to 200 $475.00 = $
> 200 $500.00 plus$50.00 per 100 additional devices(round up)
Total Number of Devices = $500.00 + $ _ $
FACP/TRANSMITTER New $200.00 = $
PERMIT FEE SUBTOTAL $
PERMIT FEE TOTAL $ 125
PLAN REVIEW FEE $
Processing/Technology Fee $25.00
TOTAL $
I hereby certify that I am the ❑ Owner, ❑Applicant, 0 Contractor,and authorized to sign this application and that the above
information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance
with the laws rules and regulation of the State of Washington,and the City of Arlington.
Devin Dedman 01 /22/24
Signature Print Name Date
SAVE PRINT
REV2022 Page 2 of 2
iAft
�'i
ES
CORPORATION
O _
7707 Fire Subscribers
IntelliNet
Feature Highlights
• Offers flexible power and configuration options.
Engineered for backward compatibility with legacy
systems.
Enables future ready capabilities.
• Provides instant Subscriber status through front
panel with Power and Trouble LEDs, a backlit LCD
display, and Menu/Silence button.
Includes dual communication/multiple •
communication technology(reporting over RF and c U`
I P).
• Improves functionality with an adaptive Graphic User Interface(GUI)for programming via smartphones,tablets, and
PCs.
Key Benefits
Built upon the solid foundation of AES-IntelliNet°patented mesh radio technology for use in private licensed wireless
networks.
• Protects Subscriber units against unauthorized access and rogue activity with a password protected Dealer Code.
• Makes programming and streamlined troubleshooting easy with user friendly interface.
• Adds integrated supervision of 7794A AES-IntelliPro full data module.
• Provides versatile power options.
Models
SubscriberslntelfiNeOl 2.0 Fire
7707P-88-M IntelliNet 2.0 Fire Subscriber,8-Zone with Multiple Communication Technologies
(MCT), Red Enclosure
IntelliNet 2.0 Fire Subscriber,8-Zone with 7794A AES-IntelliPro and Integrated
7707P 88 ULP M Onboard Local Annunciator, plus Multiple Communication Technologies(MCT), Red Enclosure
IntelliNet 2.0 Fire Subscriber,4x4 Zone(4 Reversing Polarity,4 Supervised)with
7707P 44 M Multiple Communication Technologies(MCT), Red Enclosure
IntelliNet 2.0 Fire Subscriber,4x4 Zone(4 Reversing Polarity,4 Supervised)
7707P-44-ULP-M with 7794A AES-IntelliPro and Integrated oOnboard Local Annunciator, plus Multiple
Communication Technologies
MCT, Red Enclosure
aes-corp.com
Technical Specifications
DIMENSIONS ALARM SIGNAL INPUTS/ZONES ANNUNCIATOR
13"H x 8.5"W x 4.5"D 8 Individually programmable Integrated Local Annunciator
(33cm H x 21.5cm W x 11.4cm D) E.O.L.type zone inputs
• 4x4 Option with 4 reverse PROGRAMMING INTERFACE
WEIGHT polarity input and 4 Web browser capable device
• 15.85 Ibs(7.2 kilograms)with individually programmable accessible via smartphone,tablet,
12Ah battery E.O.L.type zone inputs laptop,or PC
• 7 Ibs(3.2 kilograms)excluding Optional 7794A AES-IntelliPro
battery for full data via Contact POWER OUTPUT
ID, Pulse, Modem Ile,and 2 or 5 Watts
RADIO FREQUENCY Modem Illa2 Contact AES for other options
Standard Frequency Range:
450-470 MHz UL LISTINGS ENCLOSURE MATERIAL
Contact AES for other UHF UL 864 Standard for Control Metal with paint finish
and VHF frequencies Units and Accessories for Fire
Alarm Systems, Edition 10 FINISH COLOR
ANTENNA ULC 5559-04 Equipment for Red
2.5 dB Tamper resistant antenna Fire Signal Receiving Centers
included and Systems, Edition 1 VISUAL INDICATORS
• Front panel LCD(2 x 20
POWER INPUT TROUBLE OUTPUT—ACK alphanumeric character backlit
• 16.5V AC Class 2 Transformer DELAY/ANTENNA CUT display)
Transformer not included Form C relay,fail secure, Power and Trouble LEDs(ALM,
• 24V DC External Regulated rated 24V DC 1A resistive, Trouble,Tx, Rx,WA)
Power Supply unsupervised Menu/Silence button
• 24V DC Regulated Power
Supply from FACP AUX Power RESET BUTTON
Located on main circuit board
BACKUP BATTERY
12 Ah with 7794A; 6 Ah without, OPERATING TEMPERATURE
UL recognized lead acid gel cell 32 to 120°F(0 to 49°C)
battery
Size based on Subscriber STORAGE TEMPERATURE
configuration 14 to 140'F(-10 to 60'C)
CURRENT CONSUMPTION RELATIVE HUMIDITY
Backup Battery Power 0 to 93%, non-condensing
• Standby=.190A
• Transmit=.752A PORTS
• Optional 7794A= .165A, (1) Ethernet
Standby and Alarm (2) USBs
f in o
aes-corp.com
AES Corporation 285 Newbury St. I Peabody, MA 01960 United States
O 2023 AES Corporationand AES-IntelliNet@ are registered trademarks ofAES Corporation. / - 10252023
ES
CORPORATION
7707 Fire Subscribers
Intell►Net -
Feature Highlights
Offers Flexible power and configuration options.
Engineered for backward compatibility with legacy '
systems. -
Enables future ready capabilities. '
Provides instant Subscriber status through front ..
panel with Power and Trouble LEDs, a backlit 1-CD
display, and Menu/Silence button.
Includes dual communication/multiple
communication technology(reporting over RF and O
�s n
I P).
Improves functionality with an adaptive Graphic User Interface(GUI)for programming via smartphones,tablets, and
PCs.
Key Benefits
Built upon the solid foundation of AES-IntelliNet-'patented mesh radio technolo gy'
networks.
�V�
Protects Subscriber units against unauthorized access and rogue activity with a p , 4
Makes programming and streamlined troubleshooting easy with user friendly int face. JAN 2 2 2024
Adds integrated supervision of 7794A AES-IntelliPro Full data module.
Provides versatile power options.
Models ......
lntelfiNeO 2.0 Fire Subscribers
IntelliNet 2.0 Fire Subscriber, 8-Zone .with Multiple Communication Technologies
7707P-88-M
(MCT), Red Enclosure
IntelliNet 2.0 Fire Subscriber,8-Zone with 7794A E -WtlAo Y In
7707P-88-ULP-M � �rQr�t 4��'Q1
Onboard Local Annunciator, plus Multiple Comm rucatic� v� �,. �t���NtTsure
IntelliNet 2.0 Fire Subscriber,4x4 Zone(4 Reversi ig Polarity, •
ED
7707P-44-M Multiple Communication Technologies(MCT),Re Enclosur.
IntelliNet 2.0 Fire Subscriber,4x4 Zone(4 Reversi ' h. .,, - _ - . .
with 7794A AES-IntelliPro and Integrated oOnbo 'd Local (j��+ll(/� 6 t Ij +f ' 4jZED
7707P 44 ULP M Communication Technologies UNLESS APPROVED BY THE
MCT, Red Enclosure BUILDING INSPECTOR
aes-corp.com
Technical Specifications
DIMENSIONS ALARM SIGNAL INPUTS/ZONES ANNUNCIATOR
13"H x 8.5"W x 4.5"D 8 Individually programmable Integrated Local Annunciator
(33cm H x 21.5cm W x 11.4cm D) E.O.L.type zone inputs
• 4x4 Option with 4 reverse PROGRAMMING INTERFACE
WEIGHT polarity input and 4 Web browser capable device
• 15.85 Ibs(7.2 kilograms)with individually programmable accessible via smartphone,tablet,
12Ah battery E.O.L.type zone inputs laptop, or PC
• 7 Ibs(3.2 kilograms)excluding Optional 7794A AES-IntelliPro
battery for full data via Contact POWER OUTPUT
ID, Pulse, Modem Ile,and 2 or 5 Watts
RADIO FREQUENCY Modem IIla2 ons
Standard Frequency Range;
450-470 MHz UL LISTINGS ENCLOSURE MATERIAL
Cor�iucr foa oche; H UL 864 Standard for Control Metal with paint finish
ui�cl VHS fr'equencie; Units and Accessories for Fire
Alarm Systems, Edition 10 FINISH COLOR
ANTENNA ULC S559-04 Equipment for Red
2.5 dB Tamper resistant antenna Fire Signal Receiving Centers
included and Systems, Edition 1 VISUAL INDICATORS
• Front panel LCD(2 x 20
POWER INPUT TROUBLE OUTPUT—ACK alphanumeric character backlit
• 16.5V AC Class 2 Transformer DELAY/ANTENNA CUT display)
iro;-sformer noc inciuo'eo` Form C relay,fail secure, • Power and Trouble LEDs(ALM,
• 24V DC External Regulated rated 24V DC 1A resistive, Trouble,Tx, Rx,WA)
Power Supply unsupervised • Menu/Silence button
24V DC Regulated Power
Supply from FACP AUX Power RESET BUTTON
Located on main circuit board
BACKUP BATTERY
12 Ah with 7794A; 6 Ah without, OPERATING TEMPERATURE
UL recognized lead acid gel cell 32 to 120oF(0 to 49°C)
battery
Cize busea STORAGE TEMPERATURE
cor��rg:;ro 'on 14 to 140°F(-10 to 60oC)
CURRENT CONSUMPTION RELATIVE HUMIDITY
Backup Battery Power 0 to 93%, non-condensing
Standby=.190A
Transmit= .752A PORTS
Optional 7794A= .165A, (1) Ethernet
Standby and Alarm (2)USBs
f in o
aes-corp.com
AES Corporation 285 Ne • Peabody, 01960 United States
0 2023 AES Corporationare registered trademarks of AES Corporation. 7707_Rev4.j 02S2023