Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
8607 217th Pl NE_BLD5172_2025
i Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 591h Avenue NE • Arlington,WA 98223 • Phone (360)403-3551 Permit Number: BLD5172 Permit Type: Residential Mechanical Address/Parcel: 8607 217th PI Ne Completed (Month/Year): August 2023 Land Use ❑ Notice of Decision ❑ Bonding or Assignment of Funds ❑ Staff Report o Confidential Documents. Contact the ❑ Application City to obtain. ❑ Narrative ❑ Letters and Project Documents ❑ Legal Description ❑ Other: ❑ Vicinity Map ❑ Site Plan Civil ❑ Landscape Plan ❑ Issued Permit ❑ Complete Streets Checklist ❑ Application ❑ Traffic Impact Analysis ❑ Other Applications ❑ Snohomish County Traffic Mitigation Offer ❑ Construction Calculation Worksheet ❑ WSDOT Traffic Offer Form ❑ Approved Plans ❑ Tree Survey ❑ Review Comment Form ❑ Stormwater Drainage Report ❑ Letters and Project Documents ❑ Geotech Report ❑ Other Agency Permits ❑ Critical Area Evaluation Form ❑ Reports: ❑ SEPA Checklist o Drainage Report Pg: ❑ Public Notice Material o Stormwater Pg: ❑ Noticing and Related Documents o Geotech Pg: ❑ Water/Sewer Availability Certificate o All Other Reports ❑ Unanticipated Discovery Plan Form ❑ SEPA and Noticing Materials ❑ Aerial Photo of Site ❑ Inspections ❑ Proposed Building Materials ❑ As-Builts ❑ Lighting Plans and Lighting Cut Sheets ❑ Other: ❑ Color Elevations ❑ Design Matrix Building ❑ Plat Map ❑✓ Issued Permit ❑ Title Report ❑✓ Application ❑ Lot Closures ❑ Additional Applications ❑ Preliminary Civil Plans ❑ Approved Plans ❑ Archaeological Survey ❑✓ Site Plan o Confidential Documents. Contact the ❑ Letters and Project Documents City to obtain. ❑ Calculations ❑ Topography(Existing Conditions) ❑✓ Project Specification Manuals ❑ CC&R's ❑ Reports ❑ Deeds/Easements/Conveyances ❑ Certificate of Occupancy /Dedications ❑ Inspections ❑ Developer's Agreement ❑ Other: ❑ Recorded Copies Page 1 of 1 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 8607 217TH PL NE Permit#: 5172 Parcel#:00943300001200 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:LIKE IN KIND FURNACE CHANGE OUT Valuation:3945.26 - APPLICANT CONTRACTOR PO LLC BARRON HEATING/MAKENNA BARRON HEATING&AC INC STEINKAMP 1059 STATE AVE STE D BARRON HEATING/5100 PACIFIC 5100 PACIFIC HWY STE 103 HWY MARYSVILLE,WA 98275 FERNDALE,WA,98248 FERNDALE,WA 98248 360-676-1131 360-676-1131 LIC:BARROHA179D7 FJP:10/23/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR ' BARRON HEATING&AC INC 5100 PACIFIC HWY STE 103 FERNDALE,WA 98248 360-676-1131 LIC#:BARROHA179D7 EXP: 10/23/2024 LIC#: EXP: 0� � JOB DESCRIPTION ' PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: _ ■ PERMIT APPROVAL _ The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC l0/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 03/17/2023 02/22i2023 Applicant Signature Date Building Official Date = CONDITIONS Adhere to approved appliance.Approved permit shall be onsite during installation. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES ■ ■ Date Description Fee Amount 03/17/2023 Processing/Technology $25.00 03/17/2023 Inspection $75.00 03/17/2023 Wchanical Base $25.00 03/17/2023 Gas Piping/Units $15.00 03/17/2023 Forced A Heats 100 BTU/h $15.00 03/17/2023 Credit Card Service $4.65 Total Due: $159.65 Total Payment: $159.65 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail i RESIDENTIAL MECHANICAL APPLICATION • Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping. Please fill out all pages of this application and include all information. Type of Permit: ❑ New Installation ✓❑ Addition/Alteration/Repair ❑ Gas Piping Property Address. 8607 217TH PLACE NORTHEAST Project Valuation: $3,945.26 Lot#: Parcel ID No.: 00943300001200 Preferred Contact: ❑ Owner O Contractor Project Description: LIKE IN KIND FURNACE CHANGE OUT Owner Name: PO LLC- WINDERMERE ARLINGTON RENTAL Home No.: 360-722-4875 Email Address: ASHLEYMATTESON@WINDERMERE.COM Cell No.: 206-853-3499 Mailing Address: 210 EAST BURKE AVENUE City: ARLINGTON State: WA Zip: 98223 Contractor Name: BARRON HEATING Office No.: 360-676-1131 Email Address: MAKENNAS@BARRONHEATING.COM Cell No.: Mailing Address: 5100 PACIFIC H WY City: FERN DALE State: WA Zip: 98248 L&I Contractor License Number: BARROHA179D7 Expiration Date: 10/23/24 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Gas Piping Information O Not Applicable ❑ CSST ❑ Brass ❑ Other Proposed Piping Material: ❑ Black Steel ❑ Galvanized Steel Proposed Piping Size: ❑ 1/2" ❑ s/s" 713/4" ❑ 1" ❑ 11/2 ❑ 2" Distance from Meter to furthest Appliance: Total BTU's of all Appliances: MECHANICAL PERMIT FEES (per unit) Type of Fixture No. of Units Cost per Unit Subtotal Model No. Additional Plan Review fees x $75.00 = Air Cond.Unit<_100Btu h x $ 15.00 = Air Cond.Unit>10013tu h x $25.00 = Air Cond.Unit>50013tu h x $50.00 = Air Handling Units x $ 15.00 = Base Mechanical Fee 1 x $25.00 = $25.00 Boiler<10013tu h>3h x $ 15.00 = Boiler>1 million Btu/h<50hp x $25.00 = REV03.2022 Page 1 of 2 MECHANICAL PERMIT FEES (per unit) Boiler>1.5 million Btu h<50hp x $50.00 = Boiler>100Btu h 3-15h x $ 15.00 = Boiler>500Btu h 15-30hp x $25.00 = Commercial Hoods-Type I x $25.00 = Commercial Hoods-Type II x $50.00 = Diffusers x $ 15.00 = Dryer Ducting x $ 15.00 = Ductwork(drawings required) x $25.00 = Evaporative Coolers x $ 15.00 = Exhaust Ventilation Fans x $ 15.00 = Fireplace/Insert/Stove x $ 15.00 = Forced Air Heat<_100 Btu h 1 x $ 15.00 = 15.00 ML180UH070E36A-EQP Forced Air Heat>100 Btu h x $25.00 = Gas Clothes Dryer x $ 15.00 = Gas Fired AC 15100 Btu h x $ 15.00 = Gas Fired AC>100 Btu h x $25.00 = Gas Fired AC>500 Btu h x $50.00 = Gas Pi in <_5 units x $ 15.00 = Gas Piping>5 units (plus<5 units x $2.00 = Heat Exchangers x $ 15.00 = Heat Pump-Condensing Unit x $25.00 = Hot Water Heat Coils x $ 15.00 = Miscellaneous Appliance-regulated by x $ 15.00 = mechanical code,not otherwise specified Pkg.Units<_100btu x $25.00 = Pkg.Units>100btu x $50.00 = Range/Cook top-Gas Fired x $ 15.00 = Refrigeration Unit<_100Btu h x $ 15.00 = Refrigeration Unit>100Btu h x $25.00 = Refrigeration.Unit>500Btu h x $50.00 = Re-inspection fee x $75.00 = Residential Range Hood x $ 15.00 = Unit Heaters:5 100 Btu h x $ 15.00 = Unit Heaters>100 Btu h x $25.00 = VAV Boxes(Variable Air Volume,part of air x $ 10.00 = conditioning system) Wall Heaters-Gas Fired x $25.00 = Water Heater-Gas Fired x $25.00 = Permit Fee 15.00 Inspection Fee $75.00 Processing/Technology Fee $25.00 Total 115.00 REV2.2020 Page 2 of 2 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated I hereby certify that I am the [-]Owner, ❑Applicant, ❑Contractor, and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington.A final inspection and approval shall be obtained when complete. Signature Print Name Date SAVE PRINT REV2.2020 Page 3 of 3 I _ W • _Z 8606 21'08 a 86C2 L�� 00 N . : - IV Js N s map 86C °s �7 Z r 4 m ~ i _ - ftWIL 1 ,. -+ Google _ Map data 92023,Map data @2023 Unked States Tertna Privacy Sermi%edbw* Mft• GAS FURNACES ML180UHE LENNOXMERIT° SERIES Upflow/ Horizontal - Constant Torque Blower Motor - 60 Hz RESIDENTIAL Bulletin No.210825 July 2020 PROD UC T SPEC/FICA TONS Supersedes June 2020 o LENNDX �/ MrmRITO SERIES AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 1.5 to 5 Tons MODEL NUMBER IDENTIFICATION ML180UH07OXE36B Unit Type ---------------------- ------------------ 'Cabinet Width ML=Merit°Series ' ' ' ' ' ' A=14-1/2 in. B=17-1/2 in. Stages----------------- C=21 in. 1 =Single-Stage ; ; ; D=24 1/2 in. AF -------------UE Nominal Add-On Cooling Capacity 80=80% � i � � ` 36=1.5-3 tons 48=2.5-4 tons Configuration ---------- ; 60=3-5 tons UH=Upflow/Horizontal •--------- Blower Nominal Gas Heat Input ----------; E=High Efficiency Constant Torque Blower Motor 045=44,000 Btuh 070=66,000 Btuh 090=88,000 Btuh `--- Low NOx 110=110,000 Btuh X=Units meet California Nitrogen Oxides Standard(40 ng/J) 135=132,000 Btuh Indoor coils with the same letter designation physically match the furnace. FEATURE HIGHLIGHTS i o 1. Lennox DuralokTM Heat Exchanger Assembly 2. Inshot Burners / / - a 3. SureLight° Hot Surface Ignitor r O 4. Gas Control Valve 0 0 Q ' 5. Combustion Air Inducer 6. Flame Rollout Switches 7. Power Saver" Constant Torque Blower 8. SureLight° Integrated Furnace Control AF 9. Insulated Cabinet 10. Safety Interlock Switch h 4 11. Gas Piping And Electrical Inlets 1 � 80E FURNACES ARE NOT AVAILABLE IN CANADA! CONTENTS Approvals and Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 BlowerData . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Dimensions- Furnace/Coil Combined Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Dimensions-Optional Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Dimensions-Unit- Horizontal Position. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Dimensions-Unit-Upflow Position. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Gas Heat Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 High Altitude Derate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Installation Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Optional Accessories-Order Separately . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 ML180UHE/Page 2 APPROVALS AND WARRANTY APPROVALS • AHRI Certified • Tested and rated according to US DOE test procedures and FTC labeling regulations • "X" models approved by the California Energy Commission and meets California Nitrogen Oxides Standard (NOx) limits of 40 ng/J • ISO 9001 Registered Manufacturing Quality System • Blower data from unit tests conducted in Lennox Laboratory air test chamber California Only • These furnaces do not meet the South Coast Air Quality Management District(SCAQMD) Rule 1111 and San Joaquin Valley Air Pollution Control District(SJVAPCD) Rule 4905 NOx emission limit(14 ng/J) and cannot be installed within the SCAQMD and SJVAPCD areas • All "X"model furnaces are approved by the California Energy Commission and meets California Nitrogen Oxides Standard (NOx) limits of 40 ng/J WARRANTY • Heat Exchanger: • Limited twenty years in residential applications • Limited ten years in non-residential applications • All other covered components: • Limited five years in residential installations • Limited one year in non-residential installations NOTE- Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. FEATURES APPLICATIONS HEATING SYSTEM • Input capacities of 44,000,66,000, 88,000, 110,000 and O Lennox DuralokTM Heat Exchanger Assembly 132,000 Btuh • Heavy gauge aluminized steel heat exchanger • Energy efficiency(AFUE)-80% • Crimped seam clamshell type design • Compact cabinet • Designed for normal expansion and contraction • Upflow, horizontal-left or horizontal-right applications • Minimum resistance to air flow • Lennox add-on indoor coils, high-efficiency air cleaners • Laboratory life cycle tested in excess of industry and humidifiers can easily be added to furnace standards • Shipped factory assembled with all controls installed • Compact size permits low overall design of furnace and wired cabinet • Ready for installation in upflow or horizontal right-hand position without any modifications © Inshot Burners • Aluminized steel inshot burners provide efficient,trouble- NOTE- Horizontal left-hand position requires repositioning free operation of pressure switch. • Burner venturi mixes air and gas in correct proportion for • Removable bottom seal panel shipped in place for side proper combustion return air is easily removed for bottom/end return air . Burner assembly is removable from the unit as a single applications component for ease of service • Each unit factory test operated to ensure proper operation ®SureLight® Hot Surface Ignitor • Tough, reliable, long-life,trouble-free performance • Silicon nitride ignitor • Cemented to steatite block for protection against current leakage • Ignition leads are constructed of nickel plated copper and are enclosed in high temperature Teflon°insulation for dependable operation ML180UHE/Page 3 FEATURES HEATING SYSTEM (continued) BLOWER ®Gas Control Valve O Power Saver'" Constant Torque Blower Motor • 24 volt redundant combination gas control valve • Programmable high efficiency multi-speed blower motor. combines manual shut off switch (On-Off),automatic By maintaining constant torque output, blower motor electric valve(dual) and gas pressure regulation into a can deliver more uniform (but not constant)airflow over compact combination control the static pressure range ©Combustion Air Inducer • Programmable multi-speed operation is achieved by • Shaded pole heavy duty blower prepurges heat the use of an ECM (Electronically Commutated Motor) exchanger and safely vents flue products motor • Pressure switch proves blower operation before allowing • Leadless blower motor features simple plug-in gas valve to open connections • Operates only during heating cycle • Controlled by the Integrated Furnace Control • Direct access allows inducer assembly to be rotated 90' ' Blower speeds are easily changed on the integrated clockwise or counterclockwise to facilitate easy vent furnace control. See Blower Data tables attachment from either side of the cabinet in upflow Blower Assembly applications and from the top in horizontal applications • Lennox designed and built, direct drive blower 0 Flame Rollout Switches (2) • Each blower is statically and dynamically balanced as an • Factory installed on the front of the burner box assembly before installation in the unit • Switches provides protection from abnormal operating • Blower motor is resiliently mounted to blower assembly conditions • Blower is easily removed for servicing • Manual reset Limit Control • Primary limit is accurately located on vestibule panel • Automatic reset Optional Accessories High Altitude Pressure Switch Kit • Required on most units for proper unit operation at altitudes from 4,501 to 7500 ft. Natural Gas to LPG/Propane Conversion Kit • Required for field changeover from natural gas to LPG/ Propane LPG/Propane to Natural Gas Conversion Kit • Required for field changeover from LPG/Propane to natural gas Vent Adaptor(Upflow Applications Only) • Allows venting through a 6in. ) masonry chimney without the O52 mm need of a flue liner • Manual reset temperature sensor protects against n. �,7s 7 i n. abnormal operating conditions • Sensor wiring may be routed from either side of adaptor a� :"' • Minimum winter design temperatures: • -10°F when used with interior masonry chimneys • +5°F when used with exterior masonry chimneys NOTE-Refer to Winter Design Temperatures Map on page 8 for application information. Also refer to the installation instructions for detailed information. ML180UHE/Page 4 FEATURES CONTROLS Optional Accessories SureLight® Integrated Furnace Control iComfort° M30 Smart Wi-Fi Thermostat • Contains all necessary controls and relays to operate • Wi-Fi-enabled,electronic 7-day, universal, multi-stage, furnace programmable,touchscreen thermostat • Combustion air inducer is operated by the integrated • 4 Heat/2 Cool furnace control • Auto-changeover • Prior to ignition,a pre-purge cycle for 15 seconds is • Dual-fuel control with initiated optional outdoor sensor • After the main burners are turned off,a post-purge cycle • Controls dehumidification for 5 seconds is run during cooling mode and • Flame sensor assures safe and reliable operation humidification during • Should loss of flame occur the integrated furnace heating mode control will initiate 4 re-attempts at ignition before • Offers enhanced capabilities including humidification/ locking out unit operation for 60 minutes dehumidification/dewpoint measurement and control, • Watchguard type circuit automatically resets ignition Humiditrol°control, and equipment maintenance controls after one hour of continuous thermostat demand reminders after unit lockout,eliminating nuisance calls for service • Easy to read 4.3 in. color touchscreen (measured • Fan control consists of adjustable blower timed-off diagonally) delay(60,90, 120, 180 seconds-factory setting 90 • LCD display with backlight shows the current and set seconds) and fixed blower timed-on delay(30 seconds- temperature,time, inside relative humidity,system heating,2 seconds-cooling) status (operating mode and schedules) and outside • For air-conditioning applications, blower is automatically temperature(optional outdoor sensor required) energized on thermostat demand for cooling • Smooth Setback Recovery starts system early to • Control has low speed continuous blower speed setting achieve setpoint at start of program period for humidifier or air cleaner operation • Compressor short-cycle protection (5 minutes) • Two accessory terminals furnished for additional power • Up to four separate schedules are available plus supply requirements for 120 volt(less than 1 amp) Schedule IQT" power humidifiers and powered air cleaners • One-Touch Away Mode-A quick and easy way to set the • One additional terminal is furnished for power supply cooling and heating setpoints while away requirements for 24V(less than 0.5 amp) low voltage • Smart AwayTM-Uses geo-fencing technology accessories to determine when the homeowner is within a • Ignition control has single red LED to indicate status and predetermined distance from the home to operate the as an aid in troubleshooting system when leaving,away and arriving • Last five codes are stored in non-volatile memory • Wi-Fi remote monitoring and adjustment through a (accessible by recall button on control)for servicing home wireless network for desktop PCs, laptops and 24 Volt Transformer apps for smartphones or tablets • Factory installed on outside of control box • Smart home automation compatible with Amazon • 40VA transformer has fuse wired in series Alexa°, Google Assistant and IFTTT • Service Dashboard features online real-time monitoring Field Wiring Make-up Box of installed iComfort°thermostats • Furnished for line voltage wiring NOTE-See the iComfort° M30 Smart Wi-Fi Thermostat • Factory installed internally on left side of furnace Product Specifications bulletin in the Controls • Box may be installed on right side of furnace section for more information. Remote Outdoor Temperature Sensor • Used with the iComfort°M30 Smart Wi-Fi Thermostat • Outdoor sensor allows thermostat to display outdoor temperature NOTE-Sensor is required for the al Enhanced Dehumidification Accessory(EDA). Thermostat • Thermostat is not furnished with unit • Lennox Price Book for selection ML180UHE/Page 5 FEATURES CONTROLS (continued) CABINET Optional Accessories • Low-profile, narrow width allows easy installation Blower Relay Kit • Heavy-gauge,cold rolled steel construction (For Use With Two-Stage Outdoor Units) • Pre-painted cabinet finish • Allows furnace blower speed changes when matched • Flue outlet on top of cabinet for upflow applications, with two-stage air conditioners or heat pumps can be relocated to either side of cabinet for horizontal Furnace Twinning Kit applications • Required to operate two furnaces simultaneously • Flanges provided on supply air opening for ease of • Kit consists of twinning relays,quick connect terminals plenum connection or alignment with indoor coil and mounting hardware O• Insulated with foil faced insulation on sides and back of • Used for single-stage heating/single-stage cooling with heating compartment a single-stage thermostat • Sealed blower compartment Night Service Kit • Inner blower compartment access panel seals blower • Contains most commonly used service parts: compartment from air leakage • Furnace Control • Complete service access • Ignitor • Safety interlock switch automatically shuts off power to unit when blower compartment access panel is removed • Flame Sensor • Gas piping and electrical inlets are provided in both sides • Gas Valve of cabinet • Transformer Low Leakage Cabinet FILTER (Not Furnished) • All models have less than 2%air leakage • Filter and provisions for external mounting must be field • Meets ANSI/ASHRAE Standard 193-2010"Method provided of Test for Determining the Air Tightness of HVAC Equipment" Optional Accessories Bottom/Side Return Air Entry: Air Filter and Rack Kit for Horizontal Return Air(End) • Upflow/horizontal with bottom return air entry: Applications • Remove furnished bottom seal panel from cabinet • Washable or vacuum cleanable polyurethane frame type filter and external end return air rack • Upflow only with side return-air entry: • Rack has filter door for servicing • Corners are marked on either side of cabinet for return • Flanges on rack for duct connection air cut-out • Field installed • See dimension drawings • See dimension drawing NOTE-60C and 60D size units that require air volumes over 1800 cfm must have one of the following: Air Filter and Rack Kit for Upflow Side Return Air • Single side return air and Optional Return Air Base with NOTE-Not for use with Return Air Base transition that must accommodate required 20 x 25 x • Washable or vacuum cleanable polyurethane frame type 1 inch air filter to maintain proper velocity filter and external side return air rack available for field • Bottom return air installation • Return air from both sides • Available in single and ten pack kits • Bottom and one side return air • Rack has filter door for servicing • See Blower Performance Tables for additional • Flanges on rack for duct connection information • Field installs on either side of unit cabinet • See dimension drawing ML180UHE/Page 6 FEATURES CABINET(continued) High Performance Economizer Coil Match-Up (Commercial Applications Only) • All furnaces exactly match Lennox cased upflow indoor ' Designed for applications requiring outdoor air to be coils and horizontal indoor coils with same letter utilized in a commercial HVAC system designation (A, B,C, D) in model number • Allows the entry of fresh outdoor air for free cooling, • No adaptor required reducing the requirement for mechanical cooling • Engaging holes furnished on cabinet for alignment ' Heavy gauge galvanized steel cabinet lined with thick fiberglass insulation • Lennox uncased coils match furnaces without any Mixed air sensor,outdoor air sensor and 24VAC overhang but require an optional adaptor base or field transformer furnished fabricated transition to match furnace opening • See coil bulletin for additional information • Approved for California Title 24 building standards • ASHRAE 90.1-2010 compliant Optional Accessories • See separate Product Specifications bulletin for Horizontal Suspension Kit additional information and available control and sensor • Provides suspension of unit and indoor coil in horizontal options applications • Allows complete service access • Consists of corner mounted hanging brackets with vibration isolators, return air end support rail and hardware for assembly • Metal hanging straps must be field provided Return Air Base NOTE-On furnaces with side return air and condensate trap on the same side of the cabinet,a field fabricated transition or Return Air Base is required when using an IAQ product higher than 14-3/16 inches installed next to the unit and serviced from the front. IAQ products higher than 20 inches require a field fabricated transition. NOTE- Must be used for 60C and 60D size models with air volumes over 1800 cfm in upflow applications when only one side return is required. • Cabinet is shipped flat for easy field assembly • Pre-painted steel to match the furnace • See Dimension Drawing ML180UHE/Page 7 99% WINTER DESIGN TEMPERATURES FOR THE CONTIGUOUS UNITED STATES 5°F —10F 17T 0 —10F 27T 5°F —10F 37T m 17T 27T 37T This map is a necessarily generalized guide to temperatures in the contiguous Unites States.Temperatures shown for areas such as mountainous regions and large urban centers may not be accurate.The data used to develop this map was taken from the 1993 ASHRAE Fundamentals Handbook(Chapter 24,Table 1: Climate Conditions for the United States). Reprinted with permission from NFPA 54: National Fuel Gas Code 1999, National Fire Protection Association, Quincy, MA 02269.This reprinted material is not the complete and official position of the National Fire Protection Association on the referenced subject,which is represented only by the standard in its entirety. ML180UHE/Page 8 SPECIFICATIONS Gas Model No. ML180UH045E36A ML180UH07OE36A ML180UH07OE36B ML180UH090E48B Heating Model No. -Low Nox ML180UH045XE36A ML180UH07OXE36A ML180UH07OXE36B ML180UH09OXE48B Performance 'AFUE 80% 80% 80% 80% Input-Btuh 44,000 66,000 66,000 88,000 Output-Btuh 36,000 53,000 53,000 72,000 Temperature rise range-°F 15-45 40-70 40-70 35-65 Gas Manifold Pressure(in.w.g.) 3.5/ 10.0 3.5/10.0 3.5/ 10.0 3.5/10.0 Nat. Gas/LPG/Propane High Static-in.w.g. 0.50 0.50 0.50 0.50 Connections Flue connection-in. round 4 4 4 4 in. Gas pipe size IPS 1/2 1/2 1/2 1/2 Indoor Wheel nom.dia.x width-in. 10 x 8 10 x 10 10 x 10 10 x 10 Blower Motor Type DC Brushless DC Brushless DC Brushless DC Brushless Motor output-hp 1/2 1/2 1/2 3/4 Tons of add-on cooling 1.5-3 1.5-3 1.5-3 2.5-4 Air Volume Range-cfm 350- 1380 625- 1435 395- 1415 750- 1785 Electrical Voltage 120 volts-60 hertz- 1 phase Data Blower motor full load amps 6.8 6.8 6.8 8.4 Maximum overcurrent protection 15 15 15 15 Shipping Data lbs.- 1 package 111 111 127 142 SPECIFICATIONS Gas Model No. ML180UH09OE60C ML180UH11OE60C ML180UH135E60D Heating Model No. -Low Nox --- ML180UH11OXE60C --- Performance 'AFUE 80% 80% 80% Input-Btuh 88,000 110,000 132,000 Output-Btuh 72,000 90,000 107,000 Temperature rise range-°F 30-60 35-65 30-60 Gas Manifold Pressure (in. w.g.) 3.5/10.0 3.5/10.0 3.5/10.0 Nat. Gas/LPG/Propane High Static-in.w.g. 0.50 0.50 0.50 Connections Flue connection-in. round 4 4 4 in. Gas pipe size IPS 1/2 1/2 1/2 Indoor Wheel nom. dia.x width-in. 11-1/2 x 10 11-1/2 x 10 11 x 11 Blower Motor Type DC Brushless DC Brushless DC Brushless Motor output-hp 1 1 1 Tons of add-on cooling 3-5 3-5 3.5-5 Air Volume Range-cfm 990-2290 920-2315 1140-2495 Electrical Voltage 120 volts-60 hertz- 1 phase Data Blower motor full load amps 10.9 10.9 10.9 Maximum overcurrent protection 15 15 15 Shipping Data lbs.- 1 package 152 160 178 NOTE-Filters and provisions for mounting are not furnished and must be field provided. 'Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations.Isolated combustion system rating for non-weatherized furnaces. INSTALLATION CLEARANCES UPFLOW POSITION HORIZONTAL POSITION Vent Type Type B1 Type C Vent Type Type B1 Type C Sides 0(0) ' 0(0) End ' 2(51) ' 2(51) Rear 0 0 0 0 Rear 0 0 0 0 Top 1 25 1 25 Top 10(0) ' 0 0 Front 2-1/4 57 2-1/4 57 Front 2-1/4 57 2-1/4 57 Front service/alcove 24 610 24 610 Front service 24 610 24 610 Floor Combustible Combustible Floor Combustible Combustible Flue 1 1 25 6 152 Flue 1 1 25 6 152 NOTE-Air for combustion must conform to the methods outlined in the National NOTE-Air for combustion must conform to the methods outlined in the National Fuel Gas Code(NFPA 54/ANSI-Z223.1). Fuel Gas Code(NFPA 54/ANSI-Z223.1). NOTE-In the U.S.flue sizing must conform to the methods outlined in the NOTE-In the U.S.flue sizing must conform to the methods outlined in the current National Fuel Gas Code(NFPA 54/ANSI-Z223.1)or applicable current National Fuel Gas Code(NFPA 54/ANSI-Z223.1)or applicable provisions of local building codes. provisions of local building codes. Left side requires 4 in.if single wall vent is used on 14-1/2 in.cabinets,2 in.on Line contact installation permissible between jacket top or sides and building 17-1/2 in.cabinets. joists. ML180UHE/Page 9 OPTIONAL ACCESSORIES - ORDER SEPARATELY "A"Width "B"Width "C"Width "D"Width Models Models Models Models CABINET ACCESSORIES Horizontal Suspension Kit-Horizontal only 51 W10 51 W10 51 W10 51 W10 Return Air Base-Upflow only 65W75 50W98 50W99 51 W00 High Performance Economizer(Commercial Only) 1OU53 1OU53 1OU53 1 OU53 CONTROLS iComfort®M30 Smart Wi-Fi Thermostat 15Z69 15Z69 15Z69 15Z69 Remote Outdoor Air Temperature Sensor X2658 X2658 X2658 X2658 Blower Relay Kit(for two-stage outdoor units) 85W66 85W66 85W66 85W66 Furnace Twinning Kit 16W72 16W72 16W72 16W72 FILTERS Air Filter and Rack Kit Horizontal (end) 87L95 87L96 871_97 87L98 Size of filter- in. 14x25x1 18x25x1 20x25x1 25x25x1 Side Return Single 44.122 44J22 44J22 44J22 Ten Pack 66K63 66K63 66K63 66K63 Size of filter- in. 16x25x1 16x25x1 16x25x1 16x25x1 NIGHT SERVICE KIT Night Service Kit 84W47 I 84W47 84W47 84W47 VENTING Vent Adaptor—6 in.corm.size upflow applications only 18M79 18M79 18M79 18M79 'Cleanable polyurethane,frame-type filter. GAS HEAT ACCESSORIES High Altitude Natural Gas to LPG/Propane Natural Gas High Altitude Pressure Switch Kit LPG/Pro ane Kit to Natural Gas Kit Input p Orifice Kit 0 -4500 ft. 4501 -7500 ft. 7501 -10,000 ft. 0-7500 ft. 7501 -10,000 ft. 0-7500 ft. 7501 -10,000 ft. 045 No Change 80W52 80W51 11 K49 11 K44 73W81 73W37 070 No Change 80W52 80W51 11 K49 11 K44 73W81 73W37 090 No Change 80W52 80W51 11 K49 11 K44 73W81 73W37 110 No Change 80W52 80W52 11 K49 11 K44 73W81 73W37 135 No Change 80W52 80W51 11 K49 11 K44 73W81 73W37 HIGH ALTITUDE DERATE NOTE - Units may be installed at altitudes up to 2000 ft. above sea level without any modifications. At altitudes above 2000 ft. units must be derated to match information in the shaded areas shown below. NOTE-This is the only permissible derate for these units. Gas Manifold Pressure(Outlet) in.w.g. Line Pressure-in.w.g. Input 0-2000 Feet 2001 -4500 Feet 4501 -7500 Feet 7501 -10,000 ft. Minimum Natural LPG/ Natural LPG/ Natural LPG/ ' Natural LPG/ Natural LPG/ Maximum Gas Propane Gas Propane Gas Propane Gas Propane Gas Propane 045 3.5 10 3.2 10 3 10 3.5 10 4.5 11 13 070 3.5 10 3.2 10 2.8 10 3.5 10 4.5 11 13 090 3.5 10 3.2 10 2.7 9.6 3.5 10 4.5 11 13 110 3.5 10 3.5 10 3 9.6 3.5 10 4.5 11 13 135 3.5 10 3.5 10 2.9 9.6 3.5 10 4.5 11 13 Natural Gas High Altitude Orifice Kit required. ML180UHE/Page 10 DIMENSIONS - UNIT - UPFLOW POSITION � 3-1/8(79) 1 NOTE-60C and 60D size units that require air volumes over 1800 cfm must have one of the following: 1. Single side return air and Optional Return Air Base 'flu u u with transition that must accommodate required D 20 x 25 x 1 inch (508 x 635 x 25 mm)air filter to maintain proper velocity. + 2. Bottom return air. SUPPLY AIR 3. Return air from both sides. OPENING 4. Bottom and one side return air. FLUE OUTLET u n u u u See Blower Performance Tables for additional information. (TOP) ®®®® nnnnn 2 Flue outlet may be horizontal but furnace must be u u u u u vented vertically n u n u u 3 Optional External Side Return Air Filter Kit is not for use with the optional Return Air Base. 'OPTIONAL L ----------�EXTERNAL 23-3/4 —(603) SIDE RETURN 25 AIR FILTER KIT (635) (Either Side) TOP VIEW 3/4(19) 27-3/4 Front Panel (705) A 3-1/4(83) B 9/16(14) 3(76)Right 19-7/16 9/16 6-3/4(171)Left (494) (14) r2 FLUE OUTLET (Either Side) 9-1/8(232)Right 3OPTIONAL 8-5/8(219)Left jELECTRICAL INLET ®Baee®®B®e®®® (Either Side) ®8ae®o®a®B®a® EXTERNAL SIDE RETURN AIR FILTER KIT 0 0 0 0 0 0 0 0 0 0 0 o a (Either Side) 33 5-3/8(137)Right \GAS PIPING INLET ®a88a88a88®e e 8 a 8 8 a B e a B B a B (838) 2-3/16(56)Left (Either Side) �8a88aBeaBBae 0 o k O —————————ELECTRICAL/ INLET(Either Side) 23 —— — �1-1/2 ® 14-3/4 (584) (38) 375 ( ) 'Side Return 14 16 Air Opening (356) (406) (Either Side) ----------- 1-15/16(49) C � � 5/8 3/4 3/4 (16) 3-1/4 23-1/2 (19) (19) (83)� 1 (597) Bottom Return Bottom Return Air Opening Air Opening FRONT VIEW SIDE VIEW A B C D Model No. in. mm in. mm in. mm in. mm ML180UH045E36A 14-1/2 368 13-3/8 340 13 330 4-3/4 121 ML180UH07OE36A ML180UH07OE36B 17-1/2 446 16-3/8 416 16 406 6-1/4 159 ML180UH09OE48B ML180UH09OE60C 21 533 19-7/8 504 19-1/2 495 8 203 ML180UH11OE60C ML180UH135E60D 24-1/2 622 23-3/8 594 23 584 9-3/4 248 ML180UHE/Page 11 DIMENSIONS - UNIT - HORIZONTAL POSITION LEFT-HAND AIR DISCHARGE Flue outlet may be from end but furnace must be vented vertically GAS PIPING rINLET (Top or Bottom) 9-1/8(232)Top AIR 8-5/8(219)Bottom 4mFLOW ELECTRICAL INLET FLUE OUTLET (Top or Bottom) (Top) \� � 3/4(19) 3(76) +1 e Front Panel 6-3/4 5-3/8(137)Top II (171) 2-3/16(56)Bottom TOP VIEW 27-3/4 FLUE 33 27-3/4 (705) (14) OUTLET �(838)� 9 (705)�(3 ) .n.m. o Homo camm mmoC 9/16 19-7/16 onomo ccmm CCCC 4-1/4 �231/2 14 (494 0000o ccnC CCCa L ( ) ) 000no coon Cnaa 108 597 ....r .... .... ® AIR ( ) ( ) SUPPLY B A a... .... FLOW A C RETURN AIR AIR .... .... OPENING D .... .... OPENING .. m. an.. ...a .. mo END VIEW 3 1/'$ FRONT VIEW END VIEW (79) RIGHT-HAND AIR DISCHARGE 1 Flue outlet may be horizontal but GAS PIPING INLET furnace must be vented vertically (Top or Bottom) AIR ELECTRICAL INLET FLOW♦ �I6-314. 1 FLUE OUTLET (Top or Bottom) 171) (Top) 3/4(19) el Front Panel o � a 3(76) 2-3/16(56)Top 5-3/8(137)Bottom 8-5/8(219)Top TOP VIEW 9-1/8(232)Bottom 27-3/4 33 1 FLUE OUTLET 27-3/4 (705)� (838)� (End) 3-1/)8 (705)� .. oa mono ..an p °° °° 19-7/16 m 23-1/2 4-1/4 moo. .... (597) (108) an.. .... + (494) 9/16 AIR m... .... .... RETURN C' A FLOW♦ ® moo. .... A SUPPLY B (14) ...°° AIR .... .n.. AIR OPENING ..n. .... °°°°° OPENING ono .... CCC..CC°.. moo. .... Conan- 3/4 9/16 END VIEW (19) FRONT VIEW END VIEW (14) A B C D Model No. in. mm in. mm in. mm in. mm ML180UH045E36A 14-1/2 368 13-3/8 340 13 330 4-3/4 121 ML180UH07OE36A ML180UH07OE36B 17-1/2 446 16-3/8 416 16 406 6-1/4 159 ML180UH09OE48B ML180UH09OE60C 21 533 19-7/8 504 19-1/2 495 8 203 ML180UH11OE60C ML180UH135E60D 24-1/2 622 23-3/8 594 23 584 9-3/4 248 ML180UHE/Page 12 DIMENSIONS - OPTIONAL ACCESSORIES HORIZONTAL (END) FILTER KIT 1-1/4 24-3/4 (32) (16) (629) 5/g n Furnace Catalog A B (16 14t Cabinet Number Width in. mm in. mm B RETURN II A 87L95 14 356 12-3/4 324 A AIR OPENING B 87L96 18 457 16-3/4 425 5/8 AIR FLOW I I C 87L97 21 533 18-3/4 476 (16) 23-1/2 D 871-98 1 25 1 635 23-3/4 603 (597) AIR FILTER"" ULJ 5/8 (Furnished) (16) SIDE VIEW FRONT VIEW Optional Return Air Base (Upflow Applications Only - For use with A, B, C and D cabinets) pcccoocccooca FURNACE ®aa88aaaee®a/ FRONT eaaaeaaaaaaaa �aaaeaaaaaaae 0 0 I ——— --I IF BASE 3-1/4 1 23(584) IS USED �� Overall QED WITHOUT (83) (Maximum) 1 Minimum IAQ CABINET, 11 (279) INDOOR AIR A SINGLE 16 QUALITY RETURN AIR Unit side return air z Maximum 22-7/ 14(356) ) CABINET PLENUM Opening i Overall AIR FLOW (PCO, Filter MUST L—________ — Cabinet,etc.) COVER BOTH J (Maximum) UNIT AND e RETURN SIDE RETURN AIR BASE 1 7-1/4 5-5/8 AIR OPENINGS OPENINGS (184) (143) — Either Side \OPTIONAL 23 14-1/2(368)A Width(65W75) RETURN (584) 3/4 17-1/2(446)B Width(50W98) AIR BASE 26-7/8 (19) 21 (533)C Width(50W99) (683) 24-1/2(622)D Width(51W00) SIDE VIEW NOTE-Optional Side Return Air Filter Kits are not for use with Optional Return Air Base. Both the unit return air opening and the base return air opening must be covered by a single plenum or IAQ cabinet. Minimum unit side return air opening dimensions for units requiring 1800 cfm or more of air(W x H):23 x 11 in.(584 x 279 mm). The opening can be cut as needed to accommodate plenum or IAQ cabinet while maintaining dimensions shown. Side return air openings must be cut in the field.There are cutting guides stenciled on the cabinet for the side return air opening.The size of the opening must not extend beyond the markings on the furnace cabinet. 2 To minimize pressure drop,the largest opening height possible, up to 14 in. (356 mm), is preferred. ML180UHE/Page 13 DIMENSIONS - FURNACE/COIL COMBINED DIMENSIONS UPFLOW POSITION C35/CX35 C35 Model No Cased Uncased A B A B C35/CX35 in. mm in. mm in. mm in. mm C35/CX35-18/24A 16-1/2 419 49-1/2 1257 14-1/8 359 47-1/8 1197 C35/CX35-18/24B C35/CX35-24A 18-1/2 470 51-1/2 1308 16-3/8 416 49-3/8 1254 C35/CX35-24B 1 --- 20-1/2521 53-1/21359 --- --- --- --- 1 C35/CX35-30A C35/CX35-30B 22-1/2 572 55-1/2 1410 20-3/4 527 53-3/4 1365 C35/CX35-30/36A 11 C35/CX35-30/36B 24-1/2 622 57-1/2 1461 22-1/4 565 55-1/4 1403 B C35/CX35-30/36C C35/CX35-36A 24-1/2 622 57-1/2 1461 22-3/8 568 55-3/8 1407 33 C35/CX35-36B V --- 24-1/2622 57-1/2 1461 --- --- --- --- C35/CX35-4813 27-1/2 699 60-1/2 1537 26-1/4 667 59-1/4 1505 C35/CX35-48C ' °°oaQ000Qo 24-1/2 622 57-1/2 1461 ° C35/CX35-49C 29-1/2 749 62-1/2 1588 28-1/2 724 61-1/2 1562 C35/CX35-50/60C 27-1/2 699 60-1/2 1537 25-7/8 657 58-7/8 1495 --- 25-1/2 648 58-1/2 1486 --- --- --- --- CX35-60C 31-1/2 800 64-1/2 1638 30-5/8 778 63-5/8 1616 CX35-60D 29-1/2 749 62-1/2 1588 28 711 61 1549 HORIZONTAL POSITION Model No. A B in. mm in. mm CH35 CH35-18A, CH35-36A, 26-1/2 673 59-1/2 1511 B 33 CH35-24A, CH35-3613, (838) CH35-24B, CH35-36C, CH35-30B, CH35-42C, A CH35-48C CH35-30A, CH35-51C 31-1/2 880 64-1/2 1638 CH35-42B, ° CH35-48B, CHX35 I 8g8og gSogo s0000 CHX35-18A, CHX35-36A, 26-1/2 673 59-1/2 1511 CHX35-24A, CHX35-3613, "upS CHX35-24B, CHX35-36C, qoq CHX35-30B, CHX35-42C, CHX35-48C CHX35-30A, CHX35-51/61C, 31-1/2 880 64-1/2 1638 CHX35-42B, CHX35-60D CHX35-48B, ML180UHE/Page 14 BLOWER DATA ML180UH045E36A PERFORMANCE (Less Filter) External Air Volume/Watts at Various Blower Speeds Static High Medium-High Medium Medium-Low Low Pressure (Black) (Brown) (Blue) (Yellow) (Red) in•w•g• cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 1380 265 1155 165 995 120 975 115 945 105 0.10 1345 270 1120 175 950 120 880 105 865 100 0.20 1320 285 1080 190 900 125 805 105 700 85 0.30 1290 295 1055 200 875 135 750 110 640 90 0.40 1265 310 1010 205 825 145 710 120 595 95 0.50 1230 315 990 215 790 155 660 125 535 100 0.60 1190 330 945 230 750 165 630 135 500 110 0.70 1165 340 915 235 705 170 570 140 435 115 0.80 1130 350 880 245 670 180 535 150 380 120 ML180UH07OE36A PERFORMANCE(Less Filter) External Air Volume/Watts at Various Blower Speeds Static High Medium-High Medium Medium-Low Low Pressure (Black) (Brown) (Blue) (Yellow) (Red) in•w•g• cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 --- --- --- --- --- --- --- --- --- --- 0.10 1435 282 1215 178 1120 147 1095 133 930 88 0.20 1400 290 1170 187 1090 154 1050 141 875 98 0.30 1365 303 1145 198 1055 164 1025 153 845 102 0.40 1335 311 1105 206 1015 172 985 160 795 110 0.50 1310 325 1075 216 980 177 945 169 760 117 0.60 1285 341 1040 224 950 187 905 175 705 125 0.70 1250 344 1010 235 905 196 865 183 665 129 0.80 1215 354 975 244 860 204 830 191 625 136 ML180UH07OE36B PERFORMANCE(Less Filter) External Air Volume/Watts at Various Blower Speeds Static High Medium-High Medium Medium-Low Low Pressure (Black) (Brown) (Blue) (Yellow) (Red) in•w•g• cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 --- --- --- --- --- --- --- --- --- --- 0.10 1415 280 1295 170 1145 145 1130 130 955 95 0.20 1355 290 1225 185 1110 150 1080 140 885 100 0.30 1330 300 1190 200 1060 160 1035 155 825 110 0.40 1290 310 1155 205 1015 175 970 160 770 120 0.50 1245 325 1115 215 980 180 930 170 695 125 0.60 1225 335 1045 230 920 190 865 180 625 135 0.70 1190 350 1000 235 855 205 790 190 540 140 0.80 1160 365 925 245 790 205 735 200 445 145 ML180UH09OE48B PERFORMANCE(Less Filter) External Air Volume/Watts at Various Blower Speeds Static High Medium-High Medium Medium-Low Low Pressure (Black) (Brown) (Blue) (Yellow) (Red) in•w•g• cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 1785 380 1570 270 1440 220 1395 190 1190 120 0.10 1755 395 1535 275 1420 230 1350 205 1140 130 0.20 1730 415 1505 290 1380 245 1310 215 1110 145 0.30 1690 435 1460 305 1345 260 1275 230 1065 155 0.40 1645 440 1435 320 1310 270 1240 240 1010 165 0.50 1615 455 1395 335 1265 285 1180 255 955 180 0.60 1590 470 1350 350 1210 290 1150 265 915 185 0.70 1545 475 1300 360 1175 305 1095 275 860 200 0.80 N/A N/A 1270 370 1140 310 1040 285 820 210 ML180UHE/Page 15 BLOWER DATA ML180UH09OE60C PERFORMANCE (Less Filter) Air Volume/Watts at Different Blower Speeds Bottom Return Air, Side Return Air from Both Sides or Single Side Return Air-Air volumes in bold (over 1800 Return Air from Bottom and One Side. cfm)require Optional Return Air Base and field fabricated External transition to accommodate 20 x 25 x 1 in. air filter in order to Static maintain proper air velocity. Pressure in.w. Medium- Medium- Medium- Medium- g• High Medium Low High Medium Low (Black) High (Blue) Low (Red) (Black) High (Blue) Low (Red) (Brown) (Yellow) (Brown) (Yellow) cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 2255 640 1940 420 1750 310 1580 230 1485 185 2290 655 1980 425 1775 310 1605 235 1495 195 0.10 2200 655 1910 440 1705 315 1535 240 1385 190 2250 675 1945 445 1730 320 1555 245 1400 190 0.20 2150 675 11865 450 11655 340 1490 260 1340 205 2210 695 11885 465 11680 340 1510 265 1350 205 0.30 2125 695 1835 475 1635 355 1450 275 1285 215 2165 715 1850 475 1645 355 1470 275 1285 215 0.40 2090 715 1800 495 1585 370 1405 285 1235 230 2135 720 1810 490 1595 370 1410 290 1225 230 0.50 2060 735 1760 510 1545 385 1370 305 1200 245 2070 735 1765 515 1545 390 1370 305 1180 245 0.60 2020 750 1725 525 1515 405 1320 320 1145 255 2030 760 1715 530 1495 405 1325 320 1140 255 0.70 1980 765 1680 540 1465 420 1265 330 1105 270 1990 775 1685 540 14501 425 1265 330 1095 270 0.80 1935 785 1635 560 1420 435 1225 350 1055 285 1950 795 11645 560 1415 435 1225 345 1040 285 ML180UH11OE60C PERFORMANCE(Less Filter) Air Volume/Watts at Different Blower Speeds Bottom Return Air,Side Return Air with Return Air from Single Side Return Air-Air volumes in bold (over 1800 Both Sides or Return Air from Bottom and One Side. cfm)require Optional Return Air Base and field fabricated External transition to accommodate 20 x 25 x 1 in. air filter in order to Static maintain proper air velocity. Pressure in.w. Medium- Medium- Medium- Medium- g• High Medium Low High Medium Low (Black) High (Blue) Low (Red) (Black) High (Blue) Low (Red) (Brown) (Yellow) (Brown) (Yellow) cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 2230 635 1945 430 1715 295 1555 230 1470 185 2315 645 1990 415 1780 300 1610 230 1510 200 0.10 2180 655 1905 445 1690 305 1510 240 1340 175 2260 655 1945 425 1740 315 1550 240 1400 185 0.20 2135 680 1865 465 1630 330 1470 260 1280 190 2210 680 1895 450 1680 335 1510 255 1350 200 0.30 2090 695 1830 480 1595 345 1440 275 12351 200 21651 700 1850 465 1650 355 1455 275 1285 210 0.40 2050 715 1785 495 11550 360 1385 285 1175 210 2130 715 1830 485 1585 365 1395 285 1230 225 0.50 2025 730 1740 520 1500 375 1340 300 1130 225 2095 730 1770 500 15351 385 1365 300 1175 235 0.60 2010 750 1710 535 1470 390 1305 320 1080 240 2055 755 1725 515 1495 400 1305 315 1135 250 0.70 1965 755 1670 555 1420 410 1255 330 1015 255 2000 765 1675 535 1465 410 1255 325 1080 265 0.80 1905 785 1635 560 1380 425 1215 350 975 270 1965 785 1640 555 1400 425 1210 345 1025 275 ML180UHE/Page 16 BLOWER DATA ML180UH135E60D PERFORMANCE(Less Filter) Air Volume/Watts at Different Blower Speeds Bottom Return Air, Side Return Air with Return Air from Single Side Return Air-Air volumes in bold (over 1800 Both Sides or Return Air from Bottom and One Side. cfm)require Optional Return Air Base and field fabricated External transition to accommodate 20 x 25 x 1 in. air filter in order to Static maintain proper air velocity. Pressure in.w. Medium- Medium- Medium- Medium- g• High Medium Low High Medium Low (Black) High (Blue) Low (Red) (Black) High (Blue) Low (Red) (Brown) (Yellow) (Brown) (Yellow) cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 2495 755 2295 590 2045 435 1845 315 1650 230 2365 725 2295 575 2005 410 1820 300 1635 235 0.10 2440 780 2220 620 2015 445 1820 330 1615 245 2350 745 2210 595 2000 435 1745 320 1530 230 0.20 2390 790 2175 640 1935 470 1735 350 1550 255 2330 775 2175 625 1945 455 1730 330 1490 250 0.30 2360 805 2140 655 18951 490 1720 370 1485 275 2245 785 2135 645 1895 475 1655 355 1425 265 0.40 2285 835 2125 675 1850 510 1660 380 1455 290 2215 810 2085 660 1840 495 1600 375 1385 285 0.50 2240 860 2060 690 1815 535 1610 400 1415 310 2175 825 2045 680 1815 505 1590 390 1340 290 0.60 2225 865 2015 715 1785 550 1535 420 1330 320 2125 845 1995 700 1765 530 1525 405 1300 310 0.70 2160 895 1955 735 1755 570 1500 440 1265 340 2095 865 1950 710 1700 545 1485 420 1260 325 0.80 2105 905 1925 750 1715 580 1435 450 1215 345 2065 880 1890 725 1680 565 1415 445 1205 345 ML180UHE/Page 17 REVISIONS Sections Description of Change Blower Data Added wire colors for different motor speeds. STAR Zad CERTIFIED- LENNIN17XX Visit at nnox.com For thea latesstt t tecechnical information,www.LennoxPros.com Contact us at 1-800-4-LENNOX NOTE-Due to Lennox'ongoing commitment to quality,Specifications,Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation,adjustment,alteration,service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2020 Lennox Industries,Inc.