Loading...
HomeMy WebLinkAbout18316 Cedarbough Loop_BLD5675_2025 i Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 591h Avenue NE • Arlington,WA 98223 • Phone (360)403-3551 Permit Number: BLD5675 Permit Type: Residential Mechanical Address/Parcel: 18316 Cedarbough Loop Completed (Month/Year): March 2024 Land Use ❑ Notice of Decision ❑ Bonding or Assignment of Funds ❑ Staff Report o Confidential Documents. Contact the ❑ Application City to obtain. ❑ Narrative ❑ Letters and Project Documents ❑ Legal Description ❑ Other: ❑ Vicinity Map ❑ Site Plan Civil ❑ Landscape Plan ❑ Issued Permit ❑ Complete Streets Checklist ❑ Application ❑ Traffic Impact Analysis ❑ Other Applications ❑ Snohomish County Traffic Mitigation Offer ❑ Construction Calculation Worksheet ❑ WSDOT Traffic Offer Form ❑ Approved Plans ❑ Tree Survey ❑ Review Comment Form ❑ Stormwater Drainage Report ❑ Letters and Project Documents ❑ Geotech Report ❑ Other Agency Permits ❑ Critical Area Evaluation Form ❑ Reports: ❑ SEPA Checklist o Drainage Report Pg: ❑ Public Notice Material o Stormwater Pg: ❑ Noticing and Related Documents o Geotech Pg: ❑ Water/Sewer Availability Certificate o All Other Reports ❑ Unanticipated Discovery Plan Form ❑ SEPA and Noticing Materials ❑ Aerial Photo of Site ❑ Inspections ❑ Proposed Building Materials ❑ As-Builts ❑ Lighting Plans and Lighting Cut Sheets ❑ Other: ❑ Color Elevations ❑ Design Matrix Building ❑ Plat Map ❑✓ Issued Permit ❑ Title Report ❑✓ Application ❑ Lot Closures ❑ Additional Applications ❑ Preliminary Civil Plans ❑ Approved Plans ❑ Archaeological Survey ❑ Site Plan o Confidential Documents. Contact the ❑ Letters and Project Documents City to obtain. ❑ Calculations ❑ Topography(Existing Conditions) ❑✓ Project Specification Manuals ❑ CC&R's ❑ Reports ❑ Deeds/Easements/Conveyances ❑ Certificate of Occupancy /Dedications ❑ Inspections ❑ Developer's Agreement ❑ Other: ❑ Recorded Copies Page 1 of 1 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 18316 CEDARBOUGH LOOP Permit#:5675 Parcel#:00738500402600 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:LIKE IN KIND GAS FURNACE CHANGE OUT Valuation:4412.00 OWNER APPLICANT CONTRACTOR LOFTIS RICHARD&WENDY CM HEATING CM HEATING INC 18316 CEDARBOUGH LOOP 1500 Industry St 1500 INDUSTRY ST STE 200 ARLINGTON,WA 98223 Everett EVERETT,WA 98203 4252590550 425-259-0550 LIC:604 949 023 EXP:07/31/2024 LIC:CMAU AP78ONH EXP:08/08/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: 2018 STORIES: 2 CONST.TYPE: VB DWELLING UNITS: OCC GROUP: R-3;Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return forma ed City of Arlington#3101. 1 O� 10/31/2023 A li Signa a Date Building Official Date CONDITIONS Adhere to approved mechanical equipment.Call for final inspection.Permit shall be onsite for inspection. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/31/2023 Processing/Technology $25.00 10/31/2023 Inspection $75.00 10/31/2023 Forced Air Heat 5 100 BTU/h $15.00 10/31/2023 Mechanical Base $25.00 Total Due: $140.00 Total Payment: $140.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail i RESIDENTIAL MECHANICAL APPLICATION • Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping. Please fill out all pages of this application and include all information. Type of Permit: ❑ New Installation ✓❑ Addition/Alteration/Repair ❑ Gas Piping Property Address. 18316 CEDARBOUGH LOOP Project Valuation: $4412 Lot#: Parcel ID No.: Preferred Contact: ❑ Owner O Contractor Project Description: LIKE IN KIND GAS FURNACE REPLACMENT Owner Name: MICHAEL HOVELAND Home No.: Email Address: HOLESHOT764@YAHOO.COM Cell No.: 2533200391 Mailing Address: 18316 CEDARBOUGH LOOP City: ARLINGTON State: WA Zip: 98223 Contractor Name: CM AIR PROS Office No.: 4252590550 Email Address: INSTALL@CMHEATING.COM Cell No.: Mailing Address: 1500 INDUSTRY ST SUITE200 City: EVERETT State: WA Zip: 98203 L&I Contractor License Number: CMAIRAP78ONH Expiration Date: 08/08/2024 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Gas Piping Information O Not Applicable ❑ CSST ❑ Brass ❑ Other Proposed Piping Material: ❑ Black Steel ❑ Galvanized Steel Proposed Piping Size: ❑ 1/2" ❑ 5/8" 713/4" ❑ 1" ❑ 11/2 ❑ 2" Distance from Meter to furthest Appliance: Total BTU's of all Appliances: MECHANICAL PERMIT FEES (per unit) Type of Fixture No. of Units Cost per Unit Subtotal Model No. Additional Plan Review fees x $75.00 = Air Cond.Unit<_100Btu h x $ 15.00 = Air Cond.Unit>10013tu h x $25.00 = Air Cond.Unit>50013tu h x $50.00 = Air Handling Units x $ 15.00 = Base Mechanical Fee 1 x $25.00 = $25.00 Boiler<10013tu h>3h x $ 15.00 = Boiler>1 million Btu/h<50hp x $25.00 = REV03.2022 Page 1 of 2 MECHANICAL PERMIT FEES (per unit) Boiler>1.5 million Btu h<50hp x $50.00 = Boiler>100Btu h 3-15h x $ 15.00 = Boiler>500Btu h 15-30hp x $25.00 = Commercial Hoods-Type I x $25.00 = Commercial Hoods-Type II x $50.00 = Diffusers x $ 15.00 = Dryer Ducting x $ 15.00 = Ductwork(drawings required) x $25.00 = Evaporative Coolers x $ 15.00 = Exhaust Ventilation Fans x $ 15.00 = Fireplace/Insert/Stove x $ 15.00 = Forced Air Heat<_100 Btu h 1 x $ 15.00 = $15 Forced Air Heat>100 Btu h x $25.00 = Gas Clothes Dryer x $ 15.00 = Gas Fired AC 15100 Btu h x $ 15.00 = Gas Fired AC>100 Btu h x $25.00 = Gas Fired AC>500 Btu h x $50.00 = Gas Pi in <_5 units x $ 15.00 = Gas Piping>5 units (plus<5 units x $2.00 = Heat Exchangers x $ 15.00 = Heat Pump-Condensing Unit x $25.00 = Hot Water Heat Coils x $ 15.00 = Miscellaneous Appliance-regulated by x $ 15.00 = mechanical code,not otherwise specified Pkg.Units<_100btu x $25.00 = Pkg.Units>100btu x $50.00 = Range/Cook top-Gas Fired x $ 15.00 = Refrigeration Unit<_100Btu h x $ 15.00 = Refrigeration Unit>100Btu h x $25.00 = Refrigeration.Unit>500Btu h x $50.00 = Re-inspection fee x $75.00 = Residential Range Hood x $ 15.00 = Unit Heaters:5 100 Btu h x $ 15.00 = Unit Heaters>100 Btu h x $25.00 = VAV Boxes(Variable Air Volume,part of air x $ 10.00 = conditioning system) Wall Heaters-Gas Fired x $25.00 = Water Heater-Gas Fired x $25.00 = Permit Fee $40 Inspection Fee $75.00 Processing/Technology Fee $25.00 Total $140.00 REV2.2020 Page 2 of 2 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated I hereby certify that I am the [-]Owner, ❑Applicant, 0 Contractor, and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington.A final inspection and approval shall be obtained when complete. KAILANA MONIZ 10/30/2023 Signature Print Name Date SAVE PRINT REV2.2020 Page 3 of 3 GM9SWIGOS80Air Conditioning&Heating HEATING INPUT:40,000-120,000 BTU/H SINGLE-STAGE, MULTI-SPEED ECM, MULTI-POSITION GAS FURNACE -- 80%AFUE �--r Contents Nomenclature........................................2 Product Specifications...........................3 Dimensions............................................5 Airflow Data...........................................7 Wiring Diagrams..................................19 Accessories..........................................20 ••• Minimum Filter Sizes ..........................20 wool Standard Features Cabinet Features • Heavy-duty aluminized-steel dual- Installation: diameter tubular heat exchanger — GM9S80-upflow, • Single-stage gas valve horizontal left or right • Durable Hot-surface igniter — GC9S80-downflow, • Quiet,single-speed draft induced horizontal left or right • Self-diagnostic control board • Convenient left or right connection • Color-coded low-voltage terminals for gas and electrical service • Multi-speed ECM blower motor • Heavy-gauge steel cabinet with durable baked-enamel finish • California Low NOx emissions models available • Foil faced insulated heat exchanger • Can no longer be installed in California's South Coast Air Quality Management District (SCAQMD)on or after October 1,2019. • AHRI Certified; ETL Listed LIFETIME 10 PARTS LTTI_ COMPANY WITH COMPANY WITH HEAT EXCXAN•ER LIMITED C I us DUALITY SYSTEM ENVIRONMENTAL SYSTEM CERTIFIED BY DNV GL CERTIFIED BV DNV GL L INITEO WARRANTY' YEAR WARRANTY' `""� IS09801= =ISO ISY1= Intertek -Mir * Complete warranty details available from your local dealer or at www.goodmanmfg.com.To receive the Lifetime Heat BBB_ Exchanger Limited Warranty(good for as long as you own your home)and 10-Year Parts Limited Warranty,online registration must be completed within 60 days of installation.Online registration is not required in California or Quebec. SS-GM9S80/GC9S80 www.goodmanmfg.com 05/22 Supersedes 08/21 NOMENCLATURE G M 9 C 80 060 3 B N ** 1 2 3 4 5,6 7,8,9 10 11 12 13,14 BRAND ENGINEERING G-Goodman®Brand Major/Minor Revisions A-Initial Release B-1st Revision CONFIGURATION NOX M-Upflow/Horizontal N=>40 NG/J NOx C-Downflow/Horizontal X=<40 NG/J NOx U=<14NG/J NOx MOTOR CABINET WIDTH 9-Nine Speed ECM A-14" C-21" B-17W' D-24X" GAS VALVE MAXIMUM CFM S-Single Stage 3-1200 CFM 4-1600 CFM C-Two Stage 5-2000 CFM AFUE MBTU/H 80-80%AFUE 92-92%AFUE 030-30,000 BTU/h 080-80,000 BTU/hz 96-96%AFUE 97-97%AFUE 040-40,000 BTU/h 100-100,000 BTU/h 060-60,000 BTU/h 120-120,000 BTU/h 2 www.goodmanmfg.com SS-GM9S80/GC9S80 GM9S80 PRODUCT SPECIFICATIONS HEATING CAPACITY Input 40,000 60,000 60,000 60,000 80,000 80,000 80,000 80,000 100,000 120,000 Natural Gas Output 32,000 48,000 48,000 48,000 64,000 64,000 64,000 64,000 80,000 96,000 LP Gas Output 32,000 48,000 48,000 48,000 64,000 64,000 64,000 64,000 80,000 96,000 AFUE' 80 80 80 80 80 80 80 80 80 80 Available AC @ 0.5"ESP 3 3 3 4 3 4 4 5 5 5 Temperature Rise Range(°F) 25-55 20-50 20-50 20-50 35-65 35-65 35-65 35-65 35-65 40-70 CIRCULATOR BLOWER Size (D x W) 10"x 6" 10"x 6" 10"x 8" 10"x 8" 10"x 8" 10"x 8" 10"x 10" 10"x 10" 10"x 10" 10"x 10" Horsepower @1075 RPM 0.5 0.5 0.5 0.75 0.5 0.75 0.75 0.75 0.75 1 Speed 9 9 9 9 9 9 9 9 9 9 Vent Diameter Z 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" No.of Burners 2 3 3 3 4 4 4 4 5 6 ELECTRICAL DATA Min.Circuit Ampacity a 8.7 8.7 8.7 12.45 8.7 12.45 12.45 12.45 12.45 15.3 Max.Overcurrent Device(amps)° 15 15 15 15 15 15 15 15 15 20 SHIP WEIGHT(LBS) 86 90 100 108 116 120 132 132 132 132 DOE AFUE based upon Isolated Combustion System(ICS) Z Vent and combustion air diameters may vary depending upon vent length.Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1(in the USA)and the Canada National Standard of Canada,CAN/CSA B149.1 and CAN/CSA B142.2(in Canada). s Minimum Circuit Ampacity=(1.25 x Circulator Blower Amps)+ID Blower amps.Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sizes. ° Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 115 VAC,60 Hz,single-phase electrical supply. • Gas Service Connection%"FPT • Important:Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. SS-GM9S80/GC9S80 www.goodmanmfg.com 3 GC9S80 PRODUCT SPECIFICATIONS HEATING CAPACITY Input 40,000 60,000 80,000 80,000 100,000 Natural Gas Output 32,000 48,000 64,000 64,000 80,000 LP Gas Output 32,000 48,000 64,000 64,000 80,000 AFUE' 80 80 80 80 80 Available AC @ 0.5"ESP 3 3 4 5 5 Temperature Rise Range(°F) 25-55 30-60 35-65 35-65 40-70 CIRCULATOR BLOWER Size (DxW) 10"X6" 10"X6" 10"X8" 101,X10" 101,X10" Horsepower @1075 RPM 1/2 1/2 3/4 1 1 Speed 9 9 9 9 9 Vent Diameter z 4" 4" 4" 4" 4" No.of Burners 2 3 4 4 5 ELECTRICAL DATA Min.Circuit Ampacity 3 8.7 8.7 12.45 15.3 15.3 Max.Overcurrent Device(amps)° 15 15 15 20 20 SHIP WEIGHT(LBS) 90 94 107 115 115 DOE AFUE based upon Isolated Combustion System(ICS) a Vent and combustion air diameters may vary depending upon vent length.Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1(in the USA)and the Canada National Standard of Canada,CAN/CSA B149.1 and CAN/CSA B142.2(in Canada). 3 Minimum Circuit Ampacity=(1.25 x Circulator Blower Amps)+ID Blower amps.Wire size should be determined in accor- dance with National Electrical Codes.Extensive wire runs will require larger wire sizes. ° Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size.May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 115 VAC,60 Hz,single-phase electrical supply. • Gas Service Connection%"FPT • Important:Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. 4 www.goodmanmfg.com SS-GM9S80/GC9S80 GM9S80 DIMENSIONS Alternate Gas Inlet Alt.Flue Outlet—Horizontal Left A 17/16' B i9i„ 33%" Alt.Gas Inlet 2U 235,6" Alt. High Voltage High-Voltage Inlet 0 13'/<<" Low-Voltage Inlet �/ 1 Alt.Low Voltage 28" 23" •. MODEL !IV19S800403A* 14" 12%" GM9S800804B* 17%" 16" GM9S800603A* 14" 12%" GM9S800804C* 21" 19'/:" GM9S8006036* 17%" 16" GM9S800805C* 21" 19'/:" GM9S8006046* 17%" 16" GM9S801005C* 21" 19'/:" GM9S800803B* 17%" 16" GM9S801205D* 24%" 23" NOTES • Line voltage wiring can enter through the right or left side of furnace. Low-voltage wiring can enter through the right or left side of furnace. • Conversion kits for high-altitude(4500+ft)natural gas operation are available. Contact your Goodman distributor or dealer for details. • Installer must supply the following gas line fittings,according to which entrance is used: Left:One 90°street elbow;one 2%"pipe nipple;one 90°elbow;straight pipe;one ground joint union Right:Straight pipe to reach gas valve MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS SIDES REAR FRONT' VENT 2 .• 1" 0" 3" 6" 1" 1" 24"clearance for serviceability recommended. 2 Single Wall Vent(SW)to be used only as a connector.Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1(in the USA)and the Canada National Standard of Canada,CAN/CSA B149.1 and CAN/CSA 8142.2(in Canada). Note:AMES80 approved for line contact in the horizontal position. SS-GM9S80/GC9S80 www.goodmanmfg.com 5 GC9S80 DIMENSIONS �— 28" A 19%" B High-Voltage Electrical Low-Voltage , Electrical 0 00 Gas Inlet 33 O 18%" 11W, o 0 0 NON-COMBUSTIBLE FLOOR GC9S800403A* 14" 12%" SBT14 GC9S800603A* 14" 12%" SBT14 GC9S800804B* 17%" 16" SBT17 GC9S800805C* 21" 19%" SBT17 GC9S801005C* 21" 19%" SBT21 NOTES • Line voltage wiring can enter through the right or left side of furnace. Low-voltage wiring can enter through the right or left side of furnace. • Conversion kits for high-altitude(4500+ft)natural gas operation are avail- able.Contact your Goodman distributor or dealer for details. MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS SIDES REAR FRONT' VENT 2 .• 1" 0" 3" 6" 1" 1" 24"clearance for serviceability recommended. Z Single Wall Vent(SW)to be used only as a connector.Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1(in the USA)and the Canada National Standard of Canada,CAN/CSA B149.1 and CAN/CSA B142.2(in Canada). Note:GMES80 approved for line contact in the horizontal position. 6 www.goodmanmfg.com SS-GM9S80/GC9S80 GM9S80 LOW STAGE COOLING AIRFLOW DATA COOLINGLOW STAGE • COLUMN)EXTERNAL STATIC PRESSURE,(INCHES WATER Rq R 658 585 545 495 444 390 332 151 F02 749 697 652 607 554 509 459 406 F03 925 881 840 800 760 721 681 645 F04^ 882 841 800 760 719 678 641 602 G M 9580 0403A* Y/Y1 F05 1330 1295 1273 1251 1223 1195 1168 1142 F06 1130 1090 1059 1022 991 957 926 895 F07 1158 1113 1090 1057 1024 996 964 935 F08 1270 1235 1208 1179 1147 1119 1088 1060 F09 1417 1380 1359 1336 1314 1288 1261 1238 F01 659 599 542 490 437 383 320 N/A F02 1268 1221 1188 1154 1122 1091 1060 1029 FOB 1087 1044 1008 973 938 905 871 841 F04^ 1118 1070 1033 997 963 929 896 865 G M 9S80 Y/Y1 F05 1308 1262 1224 1197 1167 1141 1117 1089 0603A* F06 868 823 780 741 699 662 624 584 F07 922 877 835 795 757 718 679 642 F08 1382 1341 1311 1291 1263 1234 1206 1177 F09 1492 1448 1409 1381 1354 1332 1310 1288 F01 720 660 614 542 468 413 359 313 F02 1289 1260 1232 1194 1161 1125 1087 1073 F03 1125 1089 1052 1013 973 947 909 863 F04^ 1252 1198 1153 1110 1069 1028 990 953 G M 9S80 Y/Y1 F05 922 872 830 786 736 683 616 565 0603B* F06 1146 1113 1076 1039 1002 969 933 891 F07 1370 1345 1317 1286 1260 1224 1187 1168 F08 1413 1386 1360 1330 1302 1270 1242 1211 F09 1544 1500 1459 1419 1387 1349 1317 1286 F01 764 695 630 559 485 415 3S8 N/A F02 1287 1235 1191 1147 1104 1062 1020 979 F03 1339 1301 1258 1217 1174 1131 1090 1048 F04^ 1396 1346 1298 1257 1217 1175 1135 1098 G M 9S80 Y/Y1 F05 1185 1135 1088 1040 992 947 901 855 0604B* F06 1500 1460 1420 1360 1380 1294 1256 1219 F07 1591 1539 1493 1454 1416 1379 1347 1311 F08 1675 1622 1583 1545 1510 1474 1440 1402 F09 1790 1741 1701 1668 1631 1599 1567 1532 F01 710 646 580 515 432 367 314 274 F02 1298 1255 1216 1178 1140 1102 1067 1028 F03 1209 1166 1124 1083 1045 1005 964 923 F04^ 1138 1091 1045 1001 959 920 876 832 G M 9S80 Y/Y1 FOS 1391 1352 1314 1278 1241 1209 1175 1140 0803B* F06 977 931 880 836 785 734 683 626 F07 1036 985 940 895 848 799 751 705 F08 1456 1414 1376 1341 1302 1270 1238 1200 F09 1533 1488 1452 1415 1383 1350 1317 1286 Note:A DEFAULT SPEED SS-GM9S80/GC9S80 www.goodmanmfg.com 7 GM9S80 LOW STAGE COOLING AIRFLOW DATA (CONT.) COOLINGLOW STAGE EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) imp F01 841 657 595 522 439 367 315 N/A F02 1141 1089 1045 1001 958 914 869 823 F03 1311 1267 1226 1189 1150 1114 1072 1034 F04^ 1395 1347 1309 1270 1233 1199 1164 1125 G M 9S80 Y/Y1 F05 1490 1447 1407 1373 1336 1303 1269 1237 0804B* F06 1553 1510 1469 1435 1401 1368 1335 1300 F07 1593 1548 1508 1474 1440 1409 1376 1343 F08 1776 1735 1695 1661 1628 1601 1570 1542 F09 1853 1812 1773 1739 1708 1679 1650 1623 F01 831 750 671 588 501 405 348 300 F02 1214 1158 1103 1045 989 936 883 823 F03 1303 1249 1191 1136 1081 1028 974 928 F04^ 1426 1375 1324 1277 1229 1177 1124 1078 G M 9S80 Y/Y1 F05 1518 1465 1418 1372 1328 1284 1237 1195 0804C* F06 1588 1539 1494 1447 1401 1358 1313 1267 F07 1710 1666 1632 1595 1554 1512 1473 1431 F08 1785 1751 1717 1675 1639 1596 1557 1516 F09 1845 1805 1771 1733 1695 1655 1618 1576 F01 837 752 671 576 501 426 361 315 F02 1316 1270 1218 1166 1114 1061 1000 962 F03 1353 1323 1286 1235 1183 1131 1085 1040 F04^ 1587 1544 1506 1459 1416 1372 1323 1281 G M 9S80 Y/Y1 F05 1731 1673 1632 1587 1546 1506 1463 1421 0805C* F06 1794 1744 1709 1671 1632 1591 1555 1513 F07 1861 1805 1761 1720 1681 1642 1603 1565 F08 1910 1873 1839 1798 1761 1723 1686 1648 F09 2110 2055 2035 2003 1973 1946 1907 1890 F01 802 724 637 551 468 389 342 294 F02 1405 1356 1308 1262 1210 1182 1155 1102 F03 1574 1531 1484 1440 1392 1357 1306 1256 F04^ 1619 1575 1526 1489 1446 1404 1355 1313 1005c*G M Y/Y1 F05 1688 1641 1600 1557 1513 1477 1428 1381 F06 1811 1769 1730 1686 1649 1610 1572 1525 F07 1857 1812 1774 1733 1697 1662 1622 1586 F08 1892 1850 1805 1774 1735 1692 1658 1621 F09 2116 2073 2039 2005 1981 1945 1909 1879 F01 851 774 692 615 535 470 411 359 F02 1677 1629 1583 1540 1498 1449 1399 1349 F03 1537 1489 1444 1404 1365 1322 1272 1211 F04^ 1416 1365 1315 1267 1220 1163 1106 1048 G M 9S80 Y/Y1 F05 1154 1098 1043 983 932 874 819 755 1205D* F06 1806 1764 1729 1688 1654 1615 1578 1535 F07 1869 1816 1773 1731 1693 1661 1629 1589 F08 1947 1903 1865 1833 1802 1769 1 1743 1708 F09 2107 2066 2030 1996 1963 1932 1899 1867 Note:^DEFAULT SPEED 8 www.goodmanmfg.com SS-GM9S80/GC9S80 GM9S80 HIGH STAGE COOLING AIRFLOW DATA HIGH STAGE COOLING AIFLOW EXTERNAL STATIC PRESSURE,(INCHES WATER • F01 658 585 545 495 444 390 332 151 F02 749 697 652 607 554 509 459 406 F03 925 881 840 800 760 721 681 645 F04 882 841 800 760 719 678 641 602 G M 9S80 Y2 F05^ 1330 1295 1273 1251 1223 1195 1168 1142 0403A* F06 1130 1090 1059 1022 991 957 926 895 F07 1158 1113 1090 1057 1024 996 964 935 F08 1270 1235 1208 1179 1147 1119 1088 1060 F09 1417 1380 1359 1336 1314 1288 1261 1238 F01 659 599 542 490 437 383 320 N/A F02 1268 1221 1188 1154 1122 1091 1060 1029 F03 1087 1044 1008 973 938 905 871 841 F04 1118 1070 1033 997 963 929 896 865 G M 9S80 Y2 F05^ 1308 1262 1224 1197 1167 1141 1117 1089 0603A* F06 868 823 780 741 699 662 624 584 F07 922 877 835 795 757 718 679 642 F08 1382 1341 1311 1291 1263 1234 1206 1177 F09 1492 1448 1409 1381 1354 1332 1310 1288 F01 720 660 614 542 468 413 359 313 F02 1289 1260 1232 1194 1161 1125 1087 1073 F03 1125 1089 1052 1013 973 947 909 863 F04 1252 1198 1153 1110 1069 1028 990 953 G M 9S80 Y2 F05^ 922 872 830 786 736 683 616 565 0603B* F06 1146 1113 1076 1039 1002 969 933 891 F07 1370 1345 1317 1286 1260 1224 1187 1168 F08 1413 1386 1360 1330 1302 1270 1242 1211 F09 1544 1500 1459 1419 1387 1349 1317 1286 F01 764 695 630 559 485 415 358 N/A F02 1287 1235 1191 1147 1104 1062 1020 979 F03 1339 1301 1258 1217 1174 1131 1090 1048 F04 1396 1346 1298 1257 1217 1175 1135 1098 G M 9S80 Y2 F05^ 1185 1135 1088 1040 992 947 901 855 0604B* F06 1500 1460 1420 1360 1380 1294 1256 1219 F07 1591 1539 1493 1454 1416 1379 1347 1311 F08 1675 1622 1583 1545 1510 1474 1440 1402 F09 1790 1741 1701 1668 1631 1599 1567 1532 F01 710 646 580 515 432 367 314 274 F02 1298 1255 1216 1178 1140 1102 1067 1028 F03 1209 1166 1124 1083 1045 1005 964 923 F04 1138 1091 1045 1001 959 920 876 832 G M 9S80 Y2 F05^ 1391 1352 1314 1278 1241 1209 1175 1140 0803B* F06 977 931 880 836 785 734 683 626 F07 1036 985 940 895 848 799 751 705 F08 1456 1414 1376 1341 1302 1270 1238 1200 F09 1533 1488 1452 1415 1383 1350 1317 1286 Note:^DEFAULT SPEED SS-GM9S80/GC9S80 www.goodmanmfg.com 9 GM9S80 HIGH STAGE COOLING AIRFLOW DATA (CONT.) COOLINGHIGH STAGE EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) F01 841 657 595 522 439 367 315 N/A F02 1141 1089 1045 1001 958 914 869 823 F03 1311 1267 1226 1189 1150 1114 1072 1034 F04 1395 1347 1309 1270 1233 1199 1164 1125 G M9S80 Y2 F05^ 1490 1447 1407 1373 1336 1303 1269 1237 08046* F06 1553 1510 1469 1435 1401 1368 1335 1300 F07 1593 1548 1508 1474 1440 1409 1376 1343 F08 1776 1735 1695 1661 1628 1601 1570 1542 F09 1853 1812 1773 1739 1708 1679 1650 1623 F01 831 750 671 588 501 405 348 300 F02 1214 1158 1103 1045 989 936 883 823 F03 1303 1249 1191 1136 1081 1028 974 928 F04 1426 1375 1324 1277 1229 1177 1124 1078 G M9S80 Y2 F05^ 1518 1465 1418 1372 1328 1284 1237 1195 0804C* F06 1588 1539 1494 1447 1401 1358 1313 1267 F07 1710 1666 1632 1595 1554 1512 1473 1431 F08 1785 1751 1717 1675 1639 1596 1557 1516 F09 1845 1805 1771 1733 1695 1655 1618 1576 F01 837 752 671 576 501 426 361 315 F02 1316 1270 1218 1166 1114 1061 1000 962 F03 1353 1323 1286 1235 1183 1131 1085 1040 F04 1587 1544 1506 1459 1416 1372 1323 1281 G M9S80 Y2 F05^ 1731 1673 1632 1587 1546 1506 1463 1421 0805C* F06 1794 1744 1709 1671 1632 1591 1555 1513 F07 1861 1805 1761 1720 1681 1642 1603 1565 F08 1910 1873 1839 1798 1761 1723 1686 1648 F09 2110 2055 2035 2003 1973 1946 1907 1890 F01 802 724 637 551 468 389 342 294 F02 1405 1356 1308 1262 1210 1182 1155 1102 F03 1574 1531 1484 1440 1392 1357 1306 1256 F04 1619 1575 1526 1489 1446 1404 1355 1313 G M9S80 Y2 F05^ 1688 1641 1600 1557 1513 1477 1428 1381 1005C* F06 1811 1769 1730 1686 1649 1610 1572 1525 F07 1857 1812 1774 1733 1697 1662 1622 1586 F08 1892 1850 1805 1774 1735 1692 1658 1621 F09 2116 2073 2039 2005 1981 1945 1909 1879 F01 851 774 692 615 535 470 411 359 F02 1677 1629 1583 1540 1498 1449 1399 1349 F03 1537 1489 1444 1404 1365 1322 1272 1211 F04 1416 1365 1315 1267 1220 1163 1106 1048 G M9S80 Y2 F05^ 1154 1098 1043 983 932 874 819 755 1205D* F06 1806 1764 1729 1688 1654 1615 1578 1535 F07 1869 1816 1773 1731 1693 1661 1629 1589 F08 1947 1903 1865 1833 1802 1769 1743 1708 F09 2107 2066 2030 1996 1963 1932 1899 1867 RECOMMENDED AIRFLOW SPEEDS O.CONNECTION WITH 2 STAGE OUTDOOR MODELS Note:^DEFAULT SPEED FURNACE MODEL Y2 Y1 *M9S800805C* F08 F02 *M9S801205D* F06 F05 10 www.goodmanmfg.com SS-GM9S80/GC9S80 GM9S80 CIRCULATION AIRFLOW DATA CIRCULATION AIFLOW EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) Pill III IN F01 658 585 545 495 444 390 332 151 F02 749 697 652 607 554 509 459 4 66 F03 925 881 840 800 760 721 681 645 F04 882 841 800 760 719 678 641 602 G M 9S80 I G F05 1330 1295 1273 1251 1223 1195 1168 1142 0403A* F06 1130 1090 1059 1022 991 957 926 895 F07 1158 1113 1090 1057 1024 996 964 935 F08 1270 1235 1208 1179 1147 1119 1088 1060 F09 1417 1380 1359 1336 1314 1288 1261 1238 F01 659 599 542 490 437 383 320 N/A F02 1268 1221 1188 1154 1122 1091 1060 1029 F03 1087 1044 1008 973 938 905 871 841 F04 1118 1070 1033 997 963 929 896 865 G M 9580 0603A* G F05 1308 1262 1224 1197 1167 1141 1117 1089 F06 868 823 780 741 699 662 624 584 F07 922 877 835 795 757 718 679 642 F08 1382 1341 1311 1291 1263 1234 1206 1177 F09 1492 1448 1409 1381 1354 1332 1310 1288 F01 720 660 614 542 468 413 359 313 F02 1289 1260 1232 1194 1161 1125 1087 1073 F03 1125 1089 1052 1013 973 947 909 863 F04 1252 1198 1153 1110 1069 1028 990 953 G M 9S80 G F05 922 872 830 786 736 683 616 565 0603B* F06 1146 1113 1076 1039 1002 969 933 891 F07 1370 1345 1317 1286 1260 1224 1187 1168 F08 1413 1386 1360 1330 1302 1270 1242 1211 F09 1544 1500 1459 1419 1387 1349 1317 1286 F01 764 695 630 559 485 415 358 N/A F02 1287 1235 1191 1147 1104 1062 1020 979 F03 1339 1301 1258 1217 1174 1131 1090 1048 F04 1396 1346 1298 1257 1217 1175 1135 1098 G M 9S80 G F05 1185 1135 1088 1040 992 947 901 855 0604B* F06 1500 1460 1420 1360 1380 1294 1256 1219 F07 1591 1539 1493 1454 1416 1379 1347 1311 F08 1675 1622 1583 1545 1510 1474 1440 1402 F09 1790 1741 1701 1668 1631 1599 1567 1532 F01 710 646 580 515 432 367 314 274 F02 1298 1255 1216 1178 1140 1102 1067 1028 F03 1209 1166 1124 1083 1045 1005 964 923 F04 1138 1091 1045 1001 959 920 876 832 G M 9S80 G F05 1391 1352 1314 1278 1241 1209 1175 1140 0803B* F06 977 931 880 836 785 734 683 626 F07 1036 985 940 895 848 799 751 705 F08 1456 1414 1376 1341 1302 1270 1238 1200 F09 1533 1488 1452 1415 1383 1350 1317 1286 Note:A DEFAULT SPEED SS-GM9S80/GC9S80 www.goodmanmfg.com 11 GM9S80 CIRCULATION AIRFLOW DATA (CONT.) CIRCULATION • COLUMN)EXTERNAL STATIC PRESSURE,(INCHES WATER F01 841 657 595 522 439 367 !315 N/AF02 1141 1089 1045 1001 958 914 69 823 F03 1311 1267 1226 1189 1150 1114 1072 1034 F04 1395 1347 1309 1270 1233 1199 1164 1125 G M 9S80 G F05 1490 1447 1407 1373 1336 1303 1269 1237 0804B* F06 1553 1510 1469 1435 1401 1368 1335 1300 F07 1593 1548 1508 1474 1440 1409 1376 1343 F08 1776 1735 1695 1661 1628 1601 1570 1542 F09 1853 1812 1773 1739 1708 1679 1650 1623 F01 831 750 671 588 501 405 348 300 F02 1214 1158 1103 1045 989 936 883 823 F03 1303 1249 1191 1136 1081 1028 974 928 F04 1426 1375 1324 1277 1229 1177 1124 1078 G M 958*0804C* G F05 1518 1465 1418 1372 1328 1284 1237 1195 F06 1588 1539 1494 1447 1401 1358 1313 1267 F07 1710 1666 1632 1595 1554 1512 1473 1431 F08 1785 1751 1717 1675 1639 1596 1557 1516 F09 1845 1805 1771 1733 1695 1655 1618 1576 F01 837 752 671 576 501 426 361 315 F02 1316 1270 1218 1166 1114 1061 1000 962 F03 1353 1323 1286 1235 1183 1131 1085 1040 F04 1587 1544 1506 1459 1416 1372 1323 1281 G M 9S80 G F05 1731 1673 1632 1587 1546 1506 1463 1421 0805C* F06 1794 1744 1709 1671 1632 1591 1555 1513 F07 1861 1805 1761 1720 1681 1642 1603 1565 F08 1910 1873 1839 1798 1761 1723 1686 1648 F09 2110 2055 2035 2003 1973 1946 1907 1890 F01 802 724 637 551 468 389 342 294 F02 1405 1356 1308 1262 1210 1182 1155 1102 F03 1574 1531 1484 1440 1392 1357 1306 1256 F04 1619 1575 1526 1489 1446 1404 1355 1313 G M 9S80 G F05 1688 1641 1600 1557 1513 1477 1428 1381 1005C* F06 1811 1769 1730 1686 1649 1610 1572 1525 F07 1857 1812 1774 1733 1697 1662 1622 1586 F08 1892 1850 1805 1774 1735 1692 1658 1621 F09 2116 2073 2039 2005 1981 1945 1909 1879 F01 851 774 692 615 535 470 411 359 F02 1677 1629 1583 1540 1498 1449 1399 1349 F03 1537 1489 1444 1404 1365 1322 1272 1211 F04 1416 1365 1315 1267 1220 1163 1106 1048 G M 9S80 G F05 1154 1098 1043 983 932 874 819 755 1205D* F06 1806 1764 1729 1688 1654 1615 1578 1535 F07 1869 1816 1773 1731 1693 1661 1629 1589 F08 1947 1903 1865 1833 1802 1769 1743 1708 F09 2107 2066 2030 1996 1963 1932 1899 1867 Note:^DEFAULT SPEED 12 www.goodmanmfg.com SS-GM9S80/GC9S80 GM9S80 HEATING AIRFLOW DATA HEATING AIFLOW EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) F01^^ 658 N/A 585 N/A 545 N/A 495 N/A 444 G M 9S80 F02^ 749 40 697 42 652 45 607 49 554 0403A* w/w1 F03 925 32 881 34 840 35 800 37 760 F04 882 34 841 35 800 37 760 39 719 F01^^ 659 N/A 599 N/A 542 N/A 490 N/A 437 G M 9S80 F02^ 1268 35 1221 36 1188 37 1154 38 1122 0603A* w/W1 F03 1087 41 1044 43 1008 44 973 46 938 F04 1118 40 1070 42 1033 43 997 45 963 F01^^ 720 N/A 660 N/A 614 N/A 542 N/A 468 G M 9S80 F02^ 1289 34 1260 35 1232 36 1194 37 1161 0603B* w/W1 F03 1125 40 1089 41 1052 42 1013 44 973 F04 1252 36 1198 37 1153 39 1110 40 1069 F01^^ 764 N/A 695 N/A 630 N/A 559 N/A 485 G M 9S80 F02^ 1287 35 1235 36 1191 37 1147 39 1104 0604B* w/W1 F03 1339 33 1301 34 1258 35 1217 37 1174 F04 1396 32 1346 33 1298 34 1257 35 1217 F01^^ 710 N/A 646 N/A 580 N/A 515 N/A 432 G M 9S80 F02^ 1298 46 1255 47 1216 49 1178 50 1140 0803B* w/W1 F03 1209 49 1166 51 1124 53 1083 55 1045 F04 1138 52 1091 54 1045 57 1001 59 959 F01^^ 841 N/A 657 N/A 595 N/A 522 N/A 439 G M 9S80 F02^ 1141 52 1089 54 1045 57 1001 59 958 0804B* w/W1 F03 1311 45 1267 47 1226 48 1189 50 1150 F04 1395 42 1347 44 1309 45 1270 47 1233 F01^^ 831 N/A 750 N/A 671 N/A 588 N/A 501 G M 9S80 F02^ 1214 49 1158 51 1103 54 1045 57 989 0804C* w/W1 F03 1303 45 1249 47 1191 50 1136 52 1081 F04 1426 42 1375 43 1324 45 1277 46 1229 F01^^ 837 N/A 752 N/A 671 N/A 576 N/A 501 G M 9S80 F02^ 1316 45 1270 47 1218 49 1166 51 1114 0805C* w/W1 F03 1353 44 1323 45 1286 46 1235 48 1183 F04 1587 37 1544 38 1506 39 1459 41 1416 F01^^ 802 N/A 724 N/A 637 N/A 551 N/A 468 G M 9S80 F02^ 1405 53 1356 55 1308 57 1262 59 1210 1005C* W/W 1 F03 1574 47 1531 48 1484 50 1440 51 1392 F04 1619 46 1575 47 1526 49 1489 50 1446 F01^^ 851 N/A 774 N/A 692 N/A 615 N/A 535 G M 9S80 F02^ 1677 53 1629 55 1583 56 1540 58 1498 1205D* w/W1 F03 1537 58 1489 60 1444 62 1404 63 1365 F04 AA 1416 N/A 1365 N/A 1 1315 N/A 1267 N/A 1220 Note:^DEFAULT SPEED AA NOT RECOMMENDED FOR HEATING SS-GM9S80/GC9S80 www.goodmanmfg.com 13 GC9S80 LOW STAGE COOLING AIRFLOW DATA COOLINGLOW STAGE EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) F01 712 663 610 559 514 462 395 337 F02 1120 1081 1053 1022 990 955 918 887 F03 929 891 858 815 772 737 699 664 F04^ 1073 1031 1003 969 922 891 854 822 GC9S80 Y/Y1 F05 1212 1198 1161 1138 1103 1076 1037 1007 0403A* F06 871 830 789 743 702 665 628 583 F07 825 784 741 694 650 609 563 520 F08 1274 1252 1220 1195 1169 1145 1110 1084 F09 1362 1342 1307 1273 1252 1237 1211 1185 F01 706 655 604 555 505 455 395 328 F02 1035 991 951 913 876 844 807 770 F03 932 887 844 806 767 728 689 651 F04^ 897 851 808 764 725 686 646 603 GC9S80 Y/Y1 F05 1123 1077 1041 1006 973 941 907 875 0603A* F06 1155 1113 1074 1039 1006 974 945 913 F07 1255 1214 1181 1147 1116 1087 1056 1028 F08 1388 1331 1298 1266 1235 1207 1179 1151 F09 1421 1380 1348 1318 1289 1262 1233 1207 F01 760 697 636 569 481 402 349 300 F02 1286 1238 1196 1157 1117 1077 1036 998 F03 1393 1348 1308 1270 1230 1196 1158 1123 F04^ 1459 1414 1371 1336 1297 1264 1229 1193 GC9S80 Y/Y1 F05 1753 1713 1677 1642 1611 1576 1549 1518 0804B* F06 1309 1261 1218 1182 1142 1103 1064 1025 F07 1580 1534 1495 1459 1429 1390 1356 1324 F08 1523 1483 1438 1403 1370 1336 1299 1266 F09 1643 1599 1562 1525 1491 1462 1431 1394 F01 1022 813 674 585 511 431 334 282 F02 1453 1407 1332 1259 1190 1143 1064 1003 F03 1176 1105 1020 935 864 797 729 673 F04^ 1710 1660 1613 1560 1505 1424 1353 1296 GC9S80 I Y/Y1 F05 1843 1786 1747 1690 1643 1575 1497 1435 0805C* F06 1859 1819 1779 1734 1691 1641 1593 1520 F07 2028 1982 1946 1907 1861 1814 1749 1683 F08 2096 2045 2006 1974 1927 1882 1818 1765 F09 2203 2170 2138 2113 2074 2032 1990 1948 F01 956 777 675 587 468 377 324 296 F02 1460 1404 1350 1299 1251 1203 1150 1098 F03 1561 1499 1441 1385 1336 1289 1243 1197 F04^ 1628 1571 1521 1472 1425 1380 1337 1291 GC9S80 1005C* Y/Y1 F05 1714 1659 1611 1564 1519 1473 1432 1387 F06 1833 1784 1735 1688 1645 1605 1562 1520 F07 1899 1853 1804 1761 1720 1681 1640 1602 F08 1926 1894 1849 1807 1764 1720 1683 1642 F09 2222 2174 2132 2090 2053 2013 1976 1944 Note:^DEFAULT SPEED 14 www.goodmanmfg.com SS-GM9S80/GC9S80 GC9S80 HIGH STAGE COOLING AIRFLOW DATA COOLINGLOW STAGE • COLUMN)EXTERNAL STATIC PRESSURE,(INCHES WATER F01 712 663 610 559 514 462 395 337 F02 1120 1081 1053 1022 990 955 918 887 F03 929 891 858 815 772 737 699 664 F04 1073 1031 1003 969 922 891 854 822 GC9S80 0403A* Y2 F05^ 1212 1198 1161 1138 1103 1076 1037 1007 F06 871 830 789 743 702 665 628 583 F07 825 784 741 694 650 609 563 520 F08 1274 1252 1220 1195 1169 1145 1110 1084 F09 1362 1342 1307 1273 1252 1237 1211 1185 F01 706 655 604 555 505 455 395 328 F02 1035 991 951 913 876 844 807 770 F03 932 887 844 806 767 728 689 651 F04 897 851 808 764 725 686 646 603 GC9S80 Y2 F05^ 1123 1077 1041 1006 973 941 907 875 0603A* F06 1155 1113 1074 1039 1006 974 945 913 F07 1255 1214 1181 1147 1116 1087 1056 1028 F08 1388 1331 1298 1266 1235 1207 1179 1151 F09 1421 1380 1348 1318 1289 1262 1233 1207 F01 760 697 636 569 481 402 349 300 F02 1286 1238 1196 1157 1117 1077 1036 998 F03 1393 1348 1308 1270 1230 1196 1158 1123 F04 1459 1414 1371 1336 1297 1264 1229 1193 0804E* Y2 F05^ 1753 1713 1677 1642 1611 1576 1549 1518 8046 F06 1309 1261 1218 1182 1142 1103 1064 1025 F07 1580 1534 1495 1459 1429 1390 1356 1324 F08 1523 1483 1438 1403 1370 1336 1299 1266 F09 1643 1599 1562 1525 1491 1462 1431 1394 F01 1022 813 674 585 511 431 334 282 F02 1453 1407 1332 1259 1190 1143 1064 1003 F03 1176 1105 1020 935 864 797 729 673 F04 1710 1660 1613 1560 1505 1424 1353 1296 GC9S80 Y2 F05^ 1843 1786 1747 1690 1643 1575 1497 1435 0805C* F06 1859 1819 1779 1734 1691 1641 1593 1520 F07 2028 1982 1946 1907 1861 1814 1749 1683 F08 2096 2045 2006 1974 1927 1882 1818 1765 F09 2203 2170 2138 2113 2074 2032 1990 1948 F01 956 777 675 587 468 377 324 296 F02 1460 1404 1350 1299 1251 1203 1150 1098 F03 1561 1499 1441 1385 1336 1289 1243 1197 F04 1628 1571 1521 1472 1425 1380 1337 1291 GC9S80 Y2 F05^ 1714 1659 1611 1564 1519 1473 1432 1387 1005C* F06 1833 1784 1735 1688 1645 1605 1562 1520 F07 1899 1853 1804 1761 1720 1681 1640 1602 F08 1926 1894 1849 1807 1764 1720 1683 1642 F09 2222 2174 2132 2090 2053 2013 1976 1944 RECOMMENDED AIRFLOW SPEEDS FOR CONNECTION WITH 2 STAGE OUTDOOR MODELS Note:A DEFAULT SPEED FURNACE MODEL Y2 Y1 *C9S800805C* F08 F02 SS-GM9S80/GC9S80 www.goodmanmfg.com 15 GC9S80 CIRCULATION AIRFLOW DATA CIRCULATION • EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) F01 712 663 610 559 514 462 395 337 F02 1120 1081 1053 1022 990 955 918 887 F03 929 891 858 815 772 737 699 664 F04 1073 1031 1003 969 922 891 854 822 GC9S80 G F05 1212 1198 1161 1138 1103 1076 1037 1007 0403A* F06 871 830 789 743 702 665 628 583 F07 825 784 741 694 650 609 563 520 F08 1274 1252 1220 1195 1169 1145 1110 1084 F09 1362 1342 1307 1273 1252 1237 1211 1185 F01 706 655 604 555 505 455 395 328 F02 1035 991 951 913 876 844 807 770 F03 932 887 844 806 767 728 689 651 F04 897 851 808 764 725 686 646 603 GC9S80 0603A* G F05 1123 1077 1041 1006 973 941 907 875 F06 1155 1113 1074 1039 1006 974 945 913 F07 1255 1214 1181 1147 1116 1087 1056 1028 F08 1388 1331 1298 1266 1235 1207 1179 1151 F09 1421 1380 1348 1318 1289 1262 1233 1207 F01 760 697 636 569 481 402 349 300 F02 1286 1238 1196 1157 1117 1077 1036 998 F03 1393 1348 1308 1270 1230 1196 1158 1123 F04 1459 1414 1371 1336 1297 1264 1229 1193 GC9S80 G F05 1753 1713 1677 1642 1611 1576 1549 1518 0804B* F06 1309 1261 1218 1182 1142 1103 1064 1025 F07 1580 1534 1495 1459 1429 1390 1356 1324 F08 1523 1483 1438 1403 1370 1336 1299 1266 F09 1643 1599 1562 1525 1491 1462 1431 1394 F01 1022 813 674 585 511 431 334 282 F02 1453 1407 1332 1259 1190 1143 1064 1003 F03 1176 1105 1020 935 864 797 729 673 F04 1710 1660 1613 1560 1505 1424 1353 1296 GC9S80 G F05 1843 1786 1747 1690 1643 1575 1497 1435 0805C* F06 1859 1819 1779 1734 1691 1641 1593 1520 F07 2028 1982 1946 1907 1861 1814 1749 1683 F08 2096 2045 2006 1974 1927 1882 1818 1765 F09 2203 2170 2138 2113 2074 2032 1990 1948 F01 956 777 675 587 468 377 324 296 F02 1460 1404 1350 1299 1251 1203 1150 1098 F03 1561 1499 1441 1385 1336 1289 1243 1197 F04 1628 1571 1521 1472 1425 1380 1337 1291 1005C* G F05 1714 1659 1611 1564 1519 1473 1432 1387 005C F06 1833 1784 1735 1688 1645 1605 1562 1520 F07 1899 1853 1804 1761 1720 1681 1640 1602 F08 1926 1894 1849 1807 1764 1720 1683 1642 F09 2222 2174 2132 2090 2053 2013 1976 1944 Note:^DEFAULT SPEED 16 www.goodmanmfg.com SS-GM9S80/GC9S80 GC9S80 HEATING AIRFLOW DATA HEATING AIFLOW EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) F01AA 712 N/A 663 N/A 610 N/A 559 N/A 514 GC9S80 F02A 1120 26 1081 27 1053 28 1022 29 990 0403A* W/W1 F03 929 32 891 33 858 35 815 36 772 F04 1073 28 1031 29 1003 30 969 31 922 F01AA 706 N/A 655 N/A 604 N/A 555 N/A 505 GC9S80 F02A 1035 43 991 45 951 47 913 49 876 0603A* W/W1 F03 932 48 887 50 844 53 806 55 767 F04 AA 897 N/A 851 N/A 808 N/A 764 N/A 725 F01AA 760 N/A 697 N/A 636 N/A 569 N/A 481 GC9S80 F02A 1286 46 1238 48 1196 50 1157 51 1117 0804B* W/W1 F03 1393 43 1348 44 1308 45 1270 47 1230 F04 1459 41 1414 42 1371 43 1336 44 1297 F01AA 1022 N/A 813 N/A 674 N/A 585 N/A 511 GC9S80 W/W1 F02A 1453 41 1407 42 1332 45 1259 47 1190 0805C* F03 AA 1176 N/A 1105 N/A 1020 N/A 935 N/A 864 F04 1710 35 1660 36 1613 37 1560 38 1505 F01AA 956 N/A 777 N/A 675 N/A 587 N/A 468 GC9S80 F02A 1460 51 1404 53 1350 55 1299 57 1251 1005C* W/W1 F03 1561 47 1499 49 1441 51 1385 53 1336 F04 1 1628 1 46 1571 47 1521 49 1472 1 50 1 1425 Note:A DEFAULT SPEED AA NOT RECOMMENDED FOR HEATING SS-GM9S80/GC9S80 www.goodmanmfg.com 17 TEMPERATURE RISE RANGE CHART O - O v - � x - 00 11 - o v N x Q 00 = OM U � x - O LL - LL m u - O O - N r - m F- LU LL - H w o _ O O o c:) - O aO ON N = LLI a CD coo - O LLI C° - m o - tA a \ \\ - ~ o - a F- o - H D O_N - O D a o - O F- O - � O - ON, O - O - - O O � F- 00 - m O NN O LL - U - O - O C) - - O LO - O M p � 00 O- (D LO O O O O � M N 3SI�J 3bf11Vb3dW31 18 www.goodmanmfg.com SS-GM9S80/GC9S80 WIRING DIAGRAM A O r� TO =GND 115 VAC/10160 HZ n r l POWER SUPPLY WITH OVERCURRENT ID BLOWER PRESSURE SWITCH O J11-1 PROTECTION DEVICE HOT < z Ir L SURFACE < IGNITER IK r-i WARNING:DISCONNECT POWER BEFORE c Y ——N SERVICING.WIRING N W TO UNIT MUST BE DISCONNECT PROPERLY POLARIZED 2 CIRCUIT AND GROUNDED. 1 CONNECTOR TO 115VAC/10/60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE C GY FLAME SENSOR WARNING: L rZ I x DISCONNECT POWER \. GAS VALVE HI BR BEFORE SERVICING. I .\ WIRING TO UNIT MUST BE PROPERLY POLARIZED AND I v t SOME UNITS MAY HAVE GROUNDED. olscoNNEcr 3 1 ROLL OUT SWITCH C m L-p PUI--PK--(D—c DOOR a SWITCH L J L J L J r' J E AUTO RESET PRIMARY m JUNCTION BOX LIMITCONTROL RD N GND C O .DOOR J un INDUCED AIR = DRAFT CIRCULATOR OJ BLOWER BLWR Y G A m y O z No C rDoFF BURNER COMPARTMENT GND LINE U JNEUT— to N BLOWER COMPARTMENT U 2 _ C ] AUTO RESET m HUM-0HIT rI-Ii AUXILIARY PK HUMIDIFIER $ O. LIMITCONTROL HUM __-_ O EAC �ELECTRONIC C O. AI`CLEANJRv .0 j N p IND O V`U BLWR ; U D NEUTRAL0 N _ t IND LO W HOTSURFACE w1E FE IGNITER O O m A�® FIAMESENSOR LINE 115VAC NEUTRAL IS O mm OVA CL z z P z $ TW RANSFORME J TH 131 24 VAC LM s U w RUN(IS C MANUAL SET ROL R LOUT LIMITS ITCH O H v RL1112) AUTO YLIMI BL TO AUTO RESET AUX LIMIT PRIMARY LIMIT I'] a OR RD ry I TO w F-DES BK YL rs > Fin Yi HLO It) Y m.[IRE 0PS15C NOO PRESS.SWITCHRELEFTTO RIGHT p V2 T R HLI(S) � G Z 11 C MVEu) < L7 p O G S EHUM �. x! N C MVC(11) C Q © F I GAS 5 rJ VALVE a WM11 R G C Y/Y1 Y2 O O To S B R OR ECM MTR BL INDOOR TO AIR CIRCULATOR AIR HARNESS ?N OD pp rn i G G Z Z j MICRO NJ BK _ BLWR GND 3 BK R o .3 C p x BJ� I INTERGRATED CONTROL MODULE a; E w [j� j] NOTES: h0 . ra GND 1.SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 PMRS. t>D 7 MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED R O CHASSIS BLOWER WHEN SERVICING. •L.1 CIRCULATOR BLOWER COMPARTMENT 3.IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE GROUND DOORSWITCH MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATERIAL pD (OPEN WH EN HAVING ATEMPERATURE RATING OF AT LEAST 105'0.USE COPPER y C a+ DOOR OPEN) CON.TORS ONLY. .UNIT MUST BE PER A ANENTLY GROUNDED AND CONFORM TO N.E.C. �i 5.TOO RECALL L CODESM.THE LAST 6 FAULTS,MOST RECENT TO LEAST RECENT, Seven Se ment Dis la DEPRESS SWITCH FOR MORE THAN 25ECON05 WHILE IN STANDBY N e ii 0/ Error Code Status e (NOTHERMosT—NPUTS) 0 N Internal Faults or IRQ Loss E E eE COLOR CODES: EQUIPMENT GND /07 O Lockout Due to Excessive Retries or Recycles E E 0 PK PINK FIELD GNDBR ROWN Pressure Switch Stuck Closed E E 1 WHBNHITE FIELD SPLICE Pressure Switch Open E E 2 BE BLUE SWITCH(TEMP.) Open High Limit Swit RD ch E E S GY GRAY IGNITER Flame Detected When no Flame Should be Present E E 4 RED L YELLOW SWITCH(PRESS.) Open Fuse E E 5 ORORANGE OVERCURRENT LOW Flame Signal E E 6 PU PURPLE PROT.DEVICE E Ignitor Relay FaultME E E L GIN GREEN JUNCTION BK BLACK Reversed Line Polarity orE E A TERMINAL -0- Internal Gas Valve ErrorE E b INTERNAL TO External Gas Valve ErrorE E C INTEGRATED CONTROL — Open Rollout SwitchE 1 1 .r ' � PLUG CONNECTION$ Ignitor OpenE E n 'r• LOW VOLTAGE(24V) Inducer Relay EmorE E j t LOWVOLTAGEFIELD— "�: HI VOLTAGE(115V) TWIN EmorE E H •�••��• Grounding Error 1 0 0140F02640-A HI VOLTAGE FIELD SS-GM9S80/GC9S80 www.goodmanmfg.com 19 ACCESSORIES AFE18-60A Fossil Fuel V V V V V V V V (Dual Fuel)Kit HANG20 High-Altitude V V V V V V V V V V Natural Gas Kit LPLP03 Low LP Gas V V V V V V V V V V Pressure Switch LPT-03 LP Conversion Kits V V V V V V V V V V MVK-01* Masonry Vent Kit V V V V V V V V V — * Masonry Vent Kit _ _ _ _ _ _ _ _ _ MVK 02 V (for 120k model only) * Upflow applications only MODEL SBT14 Downflow Sub-Base V V — — — 14" SBT17 Downflow Sub-Base _ _ V 17.5" SBT21 Downflow Sub-Base — — — V V 21" AFE18-60A Fossil Fuel(Dual V V V V V Fuel)Kit HANG20 High-Altitude Natu- V V V V V ral Gas Kit LPLP03 Low LP Gas Pressure V V V V V Switch LPT-03 LP Conversion Kits V V V V V MINIMUM FILTER SIZES Filter Size(in2) (1)16 x 25(Side)or (1)16 x 25(Side or Bottom) (1)16 x 25 (2)16 x 25(Side)or (2)16 x 25(Side)or (1)14 x 24(Bottom) (Side or Bottom)' (1)20 x 25(Bottom) (1)24 x 24(Bottom) MODEL# :0 GC9S80 GC9S80 GC9S80 4 i.i i . 00 Filter Size(in2) (2)10 x 20 or (2)14xX 20 or (2)14 x x 20 or (1)14 x 25(Top Return) (1)16 25(Top Return) (1)20 x 25(Top Return) MODEL# :0 GC9S80 GC9S80 4 0.0 : 0:0 Filter Size(in2) (1)16 x 25(Side)or (1)16 x 25 1-16 X 25 (1)14 x 24(Bottom) (Side or Bottom) (Side or Bottom)' Note: Other size filters of equal or greater surface area may be used;filters may also be centrally located. Use 2-16 x 25 filters on side returns or 20 x 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity. Our continuing commitment to quality products may mean a change in specifications without notice. 02022 DA/K/N COMFORT TECMNOLOQ/ESMANUFACTUR/NO.L.P. • Houston,Texas • Printed in the USA. 20 www.goodmanmfg.com SS-GM9S80/GC9S80