HomeMy WebLinkAbout18325 E Country Club Dr_BLD5402_2025 i
Permit Packet Coversheet
Community and Economic Development
City of Arlington • 18204 591h Avenue NE • Arlington,WA 98223 • Phone (360)403-3551
Permit Number: BLD5402 Permit Type: Residential Plumbing
Address/Parcel: 18325 E Country Club Dr Completed (Month/Year): EXPIRED January 2024
Land Use
❑ Notice of Decision ❑ Bonding or Assignment of Funds
❑ Staff Report o Confidential Documents. Contact the
❑ Application City to obtain.
❑ Narrative ❑ Letters and Project Documents
❑ Legal Description ❑ Other:
❑ Vicinity Map
❑ Site Plan Civil
❑ Landscape Plan ❑ Issued Permit
❑ Complete Streets Checklist ❑ Application
❑ Traffic Impact Analysis ❑ Other Applications
❑ Snohomish County Traffic Mitigation Offer ❑ Construction Calculation Worksheet
❑ WSDOT Traffic Offer Form ❑ Approved Plans
❑ Tree Survey ❑ Review Comment Form
❑ Stormwater Drainage Report ❑ Letters and Project Documents
❑ Geotech Report ❑ Other Agency Permits
❑ Critical Area Evaluation Form ❑ Reports:
❑ SEPA Checklist o Drainage Report Pg:
❑ Public Notice Material o Stormwater Pg:
❑ Noticing and Related Documents o Geotech Pg:
❑ Water/Sewer Availability Certificate o All Other Reports
❑ Unanticipated Discovery Plan Form ❑ SEPA and Noticing Materials
❑ Aerial Photo of Site ❑ Inspections
❑ Proposed Building Materials ❑ As-Builts
❑ Lighting Plans and Lighting Cut Sheets ❑ Other:
❑ Color Elevations
❑ Design Matrix Building
❑ Plat Map ❑ Issued Permit
❑ Title Report ❑✓ Application
❑ Lot Closures ❑ Additional Applications
❑ Preliminary Civil Plans ❑ Approved Plans
❑ Archaeological Survey ❑ Site Plan
o Confidential Documents. Contact the ❑ Letters and Project Documents
City to obtain. ❑ Calculations
❑ Topography(Existing Conditions) ❑✓ Project Specification Manuals
❑ CC&R's ❑ Reports
❑ Deeds/Easements/Conveyances ❑ Certificate of Occupancy
/Dedications ❑ Inspections
❑ Developer's Agreement ❑ Other:
❑ Recorded Copies
Page 1 of 1
RESIDENTIAL MECHANICAL APPLICATION
Community and Economic Development
City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360)403-3551
This application is for new, addition, altered or replaced tnechardcal installation and new or altered gas piping.
Please fill out all pages of this application and include all information.
Type of Permit: ❑ New Installation 0 Addition/Alteration/Repair ❑ Gas Piping
Property Address: 18325 E COUNTRY CLUB DR Project Valuation: 1818
Lot#: Parcel ID No.: 00832900005200 preferred Contact: ❑Owner ;I Contractor
REMOVE/REPLACE GAS WATER HEATER
Project Description:
TAMMY DOWNES 4252993655
Owner Name: Home No.:
Email Address: P E RM ITS @ FASTWATE RH E ATE R.0 0 M Cell No.:
Mailing Address: 18325 E COUNTRY CLUB City: ARLINGTON State: WA Zip: 98223
Contractor Name: FAST WATE R HEATER Office No.: 4256367056
Email Address: P E RM ITS @ FASTWATE RH EATE R.0 O M Cell No.:
Mailing Address: 11715 N. C RE E K P KWY City: BOTH E LL State: WA Zip:
98011
L&I Contractor License Number: FASTWWH 948BC Expiration Date: 1-4-2024
• New gas piping requires a pressure test hooking to any appliance
• Sediment traps(drips)are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
• Proper Combustion air and venting required for all appliances
• A shut-off valve is required within 6 feet of all appliances
Gas Piping Information C7 Not Applicable
❑CSST ❑ Brass ❑ Other
Proposed Piping Material:
❑ Black Steel ❑ Galvanized Steel
Proposed Piping Size: ❑ 1/2" ❑ 5/s" ❑ 3/a." ❑ 1" ❑ 11/i" ❑ 2"
Distance from Meter to furthest Appliance: Total BTU's of all Appliances:
I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of
the above described property will be in accordance with the laws,rules and regulation of the State of Washington.
e5igneCd v�iJa Seaml�ejs�sp/oc�s.coam 0�
StgllQay:66c9J68cJ11fi952ea9fi41146e5J45�
1yGp print Name Date
T.111 FOR STAFF USE ONLY
PERMIT# ACCEPTED BY: DATE STAMP
REV03.2022 Page 1 of
MECHANICAL PERMIT FEES (per unit)
Type of Fixture No.of Units Cost per Unit Subtotal Model No.
Additional Plan Review fees x $75.00 =
Air Cond.Unit<_100Btu/h x $15.00 =
Air Cond.Unit>100Btu h x $25.00 =
Air Cond.Unit>500Btu/h x $50.00
Air Handling Units x $15.00 =
Base Mechanical Fee 1 x $25.00 = $25.00
Boiler<100Btu h>3 hp x $15.00 =
Boiler>1 million Btu/h<50hp x $25.00 =
Boiler>1.5 million Btu/h<50hp x $50.00 =
Boiler>100Btu 3-1 5hp x $15.00 =
Boiler>500Btu 15-30hp x $25.00 =
Commercial Hoods-Type I x $25.00 =
Commercial Hoods-Type II x $50.00 =
Diffusers x $15.00 =
Dryer Ducting x $15.00 =
Ductwork(drawings required) x $25.00 =
Evaporative Coolers x $15.00 =
Exhaust/Ventilation Fans x $15.00 =
Fireplace/Insert/Stove x $15.00 =
Forced Air Heat<_100 Btu h x $15.00 =
Forced Air Heat>100 Btu/h x $25.00 =
Gas Clothes Dryer x $15.00 =
Gas Fired AC<_100 Btu h x $15.00
Gas Fired AC>100 Btu x $25.00 =
Gas Fired AC> 500 Btu h x $50.00
Gas Pi in <_ 5 units x $15.00
Gas Piping> 5 units(plus<5 units x $2.00
Heat Exchangers x $15.00
Heat Pump-Condensing Unit x $25.00
Hot Water Heat Coils x $15.00
Miscellaneous Appliance-regulated by x $15.00
mechanical code,not otherwise specified
Pkg.Units<_100btu x $25.00 =
Pkg.Units>100btu x $50.00
Ran a Cook top-Gas Fired x $15.00
Refrigeration Unit<_100Btu/h x $15.00 =
Refrigeration Unit>100Btu h x $25.00
Refrigeration.Unit>500Btu h x $50.00 =
Re-inspection fee x $75.00 =
Residential Range Hood x $15.00 =
Unit Heaters 15 100 Btu x $15.00 =
Unit Heaters>100 Btu x $25.00 =
VAV Boxes(Variable Air Volume,part of air x $10.00
conditioning system)
Wall Heaters-Gas Fired x $25.00
Water Heater-Gas Fired 1 x $25.00 = $25.00
Permit Fee 25.00
Inspection Fee $75.00
Processing/Technology Fee $25.00
Total
REV2.2020 Page 2 of 2
PERFORMANCE PLUS 0
/ 1 1 ------- ----------------
0
The new degree of comfort®
The PERFORMANCE PLUS° atmospheric
gas water heaters are engineered for more
hot water at a low operating cost t
Efficiency Longer Life
.58- .65 UEF Premium grade anode rod provides
Performance long-lasting tank protection
FHR: 69-84 gallons High Altitude Compliant
Recovery: Up to 40.4 GPH at a All models certified up to 8,500 ft.
90' F rise, depending on model above sea level, some models
certified up to 10,200 ft. See
Diagnostic Valve specifications chart""
m Self powered diagnostic Plus...
gas control valve for ■Easy to light-no matches required
improved monitoring
and service ■Temperature and pressure relief valve
Low Emissions included
Eco-friendly burner, low NOx design 0 Low lead compliant
Meets 40 ng/J NOx requirements Warranty oagna,vc
Self-Cleaning 9-Year limited warranty for tank
and parts, 2-year full in-home labor
Fights sediment and warranty` '
mineral build-up `See written warranty for complete details
Reduces fuel costs Units meet or exceed ANSI requirements and have
0 been tested according to D.O.E.procedures.Units
Maintenance Free meet or exceed the energy efficiency requirements
Burner System of NAECA,ASHRAE standard 90,ICC Code and all
state energy efficiency performance criteria.
■Exclusive air/fuel shut-off device PERFORMANCE PLUS
■Maintenance free-no filter to clean Atmospheric
■Disables the heater in the presence of 40 and 50-Gallon Capacities
flammable vapor accumulation Up to 40,000 BTU/h
Combustion Shut-off System Flame Arrestor Plate on
Maintenance Free \ LEED Point=l
See specifications chart on back.
05/23 FORM NO.THD-P+HE Re 6
1 1
The new degree of comfort®
PERFORMANCE PLUS" Atmospheric Gas S• - •
Ht to Water Water7(LBS) (UEF)y
rm
Nominal Rated Gas Input Recovery First Hour Ht.to Tank Gas Vent Conn. Ht.to Side Conn. g
Gallon Gallon Model in Thous. in G.P.H. Rat ing Vent Height Diam. Conn. Size Center T&PValve Size or
juel.,T,pe Description Capacity Capacity Number Btu/h 9-F Rise (Gallons) A B C D E F G H
Tall 50 48 XG50T0911l 40 40.4 77 62-3/4 59-1/4 21-1/2 14 3or4 8 52-1/2 3/4 165 0.64
Tall 40 38 XG40T09HE4000** 40 40.4 84 63-3/4 60-1/4 19-1/2 14 3 or4 8 53-1/2 3/4 135 0.65
Short 40 39 XG40S09HE38U0** 38 38.4 69 53-3/4 50-1/4 21-1/2 14 3 8 44 3/4 125 0.58
Tall 50 48 XP50T09HE36U0 36 36.4 77 62-3/4 59-1/4 21-1/2 14 3 or 8 52-1/2 3/4 165 0.64
Tall 40 38 XP40T09HE36U0** 36 36.4 84 63-3/4 60-1/4 19-1/2 14 3 or4 8 53-1/2 3/4 135 0.65
Short 40 39 XP40S09HE36U0** 36 36.4 69 53-3/4 50-1/4 21-1/2 14 3 8 44 3/4 125 0.58
Uniform Energy Factor and rated gallon capacity based on Department of Energy(DOE)requirements.
**Models certified up to 12,500 ft.above sea level.
FLUE O ANODEROD
*. 0
HOT O H
WATER COLD
LEED Point 1 CONNECTION WATER- 1 1
1 1 CONNECTION
1 1
' F '1 1
it E If
3/4" N.P.T.
RELIEF
VALVE
OPENING
0
C
l4 B
1/2" G
D
In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice.
Rheem Water Heating • 1115 Northmeadow Parkway,Suite 100
Roswell,Georgia 30076 • www.rheem.com
05/23 FORM NO.THD-P+HE Rev.6