Loading...
HomeMy WebLinkAbout16519 40th AVE NE Unit B152_BLD6694_2026 NPE-2 Series Tankless Water Heaters Premium Condensing Tankless Gas Water Heater Specification Sheet Certified design according to the latest ANSI Z21.10.3 - CSA 4.3 standards for both indoor and outdoor installations (with optional Outdoor Vent Kit) Compatible with 1/2" gas pipe up to 24 ft* equivalent length (*see Installation Manual for additional information) Compatible with 2" PVC vent up to 75 ft** and 3" Vent up to 150 ft** (**with no elbows) Gas Type Designed for use in Residential and Commercial applications Recirclation/ Main/Sub (see Space Heating below for available models and warranty terms) Flow Rate/Status Temperature Setting Gas Input Range Combustion/erroeCombustion/Error NPE-150S2 - 120,000 to 18,000 BTU/h NPE-180A2/S2 - 150,000 to 10,000 BTU/h Menu Button Up Button NPE-210A2/S2 - 180,000 to 12,000 BTU/h Back Button Down Button NPE-240A2/S2 - 199,900 to 13,300 BTU/h OK Button Hot Water Flow Rate Capacity (*based on 35°F temperature rise) NPE-150S2 - 6.8 GPM NPE-180A2/S2 - 8.4 GPM NPE-210A2/S2 - 10.1 GPM Certified Design Compatible with Multi-Line Control NPE-240A2/S2 - 11.2 GPM 2” PVC and 1/2” Gas Pipe Panel with Diagnostics TDR (Turndown Ratio) up to 15:1 Dual Primary and Secondary Stainless Steel Heat Exchangers for optimum efficiency and durability Built-In Advanced Multi-Line Control Panel with Setup Wizard allows adjustment of temperature settings and displays of Indoor and Outdoor operating status and error codes Venting Options TMTechnology - NPE-A2 models come with 2” Intake Cap built-in 0.5 gallon Buffer Tank and Recirculation Pump to provide 2" Coupling maximum hot water comfort (NaviCirc Crossover Valve optional) 2" Pipe Outdoor INTELLIGENT Preheating - recognizes hot water usage patterns to Vent Cap intelligently provide hot water to fixtures when needed Temperature Options - available temperature settings for Residential applications range from 97°F p to 140°F with high- temperature Commercial mode capable of up to 185°F Ready-Link Cascade Compatible for up to 32 units for increased hot water production Non-Direct Vent (Indoor) Non-Direct Vent (Outdoor) Common Vent Compatible - allows for cascade systems to use a Direct Vent (Indoor) single exhaust and/or intake pipe for up to 12 units with the use of the Common Vent Backflow Damper Collar Kit (#30014367A) Compatible with Wi-Fi Control (#PBCM-AS-001) Freeze Protection - maintains normal operation in cold weather * NPE-150S2 conditions when the unit is installed INDOORS and connected to power. Excluded For OUTDOOR installations: the ambient temperature at the installation location must be above 32°F (0°C) and below 125°F (52°C) Note Refer to the Installation Manual for additional Freeze Protection guidelines Uniform Energy Factor (listed models for use with Natural Gas and Propane) NPE-150S2 - 0.93 UEF NPE-180A2/210A2/240A2 - 0.95 UEF NPE-180S2/210S2/240S2 - 0.96 UEF Job Name: _____________________________________________ Compatible for use with Natural Gas (NG) and Propane (LP) Gas*** (*** requires installation of included Gas Conversion Kit by a qualified gas servicer) Location: ______________________________________________ Approved for installations on Manufactured Homes Engineer: _____________________________________________ Certified by CSA Group, NSF 5 and 372 Low Lead, AHRI Certified, SCAQMD Wholesaler: __________________________________________ (Rule 1146.2 Type 1 - Complies with 14 ng/J or 20 ppm NOx @ 3% O2) Contractor: ___________________________________________ Limited Warranty - 15-Year Heat Exchanger and 5-Year Parts (Residential)**** Model No.: _____________________________________________ 8-Year Heat Exchanger and 5-Year Parts (Commercial)**** Submitted to: _________________________________________ (**** full details of warranty terms available in the Navien manuals or website) Optional Accessories are available (see below) Condensate Neutralizer Plumb Easy Valve Set (3/4") Ready-Link 3" Vent Termination Remote Controller (GXXX001322 - Single Unit) NPE-2 Outdoor Vent Kit External Pump Wire (30009323A - Lead Free) Communication Cable Caps and Wall Flanges (30022717B) (GXXX001324 - Up to 6 Units) (30025801A) (GXXX001319) (30025812A - for Pipe Cover) (GXXX000546) (GXXX3873B) (GXXX001325 - Up to 16 Units) 1-NPE2-SS-001-1.1 NPE-2 Series Tankless Water Heaters Premium Condensing Tankless Gas Water Heater Front View Item NPE-150S2* NPE-180A2 NPE-180S2 NPE-210A2 NPE-210S2 NPE-240A2 NPE-240S2 Heat Capacity Natural Gas, 18,000-120,000 10,000-150,000 BTU/H 12,000-180,000 BTU/H 13,300-199,900 BTU/H (Input) Propane Gas BTU/H Uniform UEF (for NG & LP) 0.93 0.95 0.96 0.95 0.96 0.95 0.96 Energy Factor mm) 35 °F (19 °C) 6.8 GPM 8.4 GPM (32 L/m) 10.1 GPM (38 L/m) 11.2 GPM (42 L/m) (695 Temp Rise (25.8 L/m) (731 mm) 28.8 in27.4 in Flow Rate 45 °F (25 °C) 5.3 GPM 6.5 GPM (25 L/m) 7.8 GPM (30 L/m) 8.7 GPM (33 L/m) (DHW) Temp Rise (20 L/m) 67 °F (36 °C) 3.4 GPM 4.3 GPM 4.4 GPM 5.1 GPM 5.3 GPM 5.6 GPM 5.8 GPM Temp Rise (13 L/m) (16 L/m) (17 L/m) (19 L/m) (20 L/m) (21 L/m) (22 L/m) Dimensions 17.3 in (W) x 27.4 in (H) x 13.2 in (D) 62 lbs 73 lbs 68 Ibs 77 Ibs 73 lbs 77 Ibs 73 lbs Weight (28 kg) (33 kg) (31 kg) (35 kg) (33 kg) (35 kg) (33 kg) Installation Type Indoor or Outdoor Wall-Hung Venting Type Forced Draft Direct Vent Overhead View A B Ignition Electronic Ignition 10 mm) Water Pressure 15-150 PSI 1.5 in (38 mm) 14.3 in (364 mm) 0.4 in ( mm) Natural Gas Supply Pressure mm) (67 3.5 in WC-10.5 in WC 77 2.6 in (from source) in ( 3 Propane Gas Supply Pressure 8 in WC-13in WC (from source) 4.5 in (115 mm) 6.7 in (170 mm) Natural Gas Manifold Pressure –0.04 in WC - –0.03 in WC - –0.55 in WC –0.03 in WC - –0.76 in WC –0.03 in WC - –0.96 in WC (min-max) –0.40 in WC Propane Gas Manifold Pressure –0.03 in WC - –0.02 in WC - –0.55 in WC –0.02 in WC - –0.76 in WC –0.02 in WC - –0.96 in WC (min-max) –0.40 in WC Minimum Flow Rate 0.5 GPM (1.9 L/m), < 0.01 GPM (0.04 L/m) option for “A2” models** Supply Connections 3/ C D E F G Cold Water Inlet 4 in NPT Description Diameter Connection Hot Water A Air Intake 2 in Sizes Outlet 3/4 in NPT B Exhaust Gas Vent 2 in (731 mm) Gas Inlet 3/ 3 in 4 in NPT C Hot Water Outlet /4 in 28.8 Main Supply 120 V AC, 60 Hz D Gas Inlet 3/4 in 336 mm) E Recirculation Inlet 3/4 in 13.2 in ( Maximum mm) mm) Power Supply (166 61 mm) 61 Power 200 W (max 2 A), 350 W (max 4 A) with external pump connected F Condensate Outlet 1/ in in ( 2 in 6.5 2.4 in ( 2.4 Consumption G Cold Water Inlet 3/ 4 in 2.3 in (60 mm)3.0 in (77 mm) 8.3 in (212 mm) Casing Cold Rolled Carbon Steel 17.3 in (440 mm) Materials Heat Primary Heat Exchanger: Stainless Steel Exchangers Secondary Heat Exchanger: Stainless Steel NPE-180A2 / 210A2 / 240A2 2 in or 3 in PVC, CPVC, Approved Polypropylene and stainless steel Exhaust 2 in or 3 in Special Gas Vent Type BH (Class II, A/B/C) Supply Connections Venting Intake 2 in or 3 in PVC, CPVC, Approved Polypropylene and stainless steel Description Diameter C D E F 2 in or 3 in Special Gas Vent Type BH (Class II, A/B/C) A Air Intake 2 in Vent Clearances 0 in to combustibles B Exhaust Gas Vent 2 in High Elevation 10,100 feet for both NG or LP gas. Please refer to Installation Manual for additional details and instructions. C Hot Water Outlet 3/ 4 in D Gas Inlet 3/ Flame Rod, APS, Ignition Operation Detector, Water Temperature High Limit Switch, Exhaust Temperature High Limit Sensor, 4 in Safety Devices E Condensate Outlet 1/2 in 13.2 in (336 mm) mm) Power Surge Fuse, Burner High Limit Fuse, Vent Installation Detector (VID) (166 mm) F Cold Water Inlet 3/ 6.5 in in (61 4 in 2.4 in (61 mm) 2.4 * NPE-150S2 model not certified by EnergyStar ** Available for “A2” models configured in an optional ComfortFlow recirculation mode. Energy consumption will increase when the system is 2.3 in (60 mm) 11.3 in (289 mm) configured for recirculation. 17.3 in (440 mm) NPE-150S2 / 180S2 / 210S2 / 240S2 Gas-fired, tankless, condensing, wall-mounted water heater(s) shall be direct vent NPE-2 Series models as manufactured by Navien, Inc. and are certified by CSA Group to the latest edition of ANSI Standard Z21.10.3-CSA 4.3. Water heater(s) shall have a 15(5)-year limited Heat Exchanger warranty and 5(3)-year limited Parts warranty (8(5)-year Heat Exchanger and 5(3)-year Parts for Commercial use) per Navien Limited Warranty. Unit(s) shall be designed to burn natural gas and can be for use with propane when a Gas Conversion Kit is installed. ________ (qty). NPE water heater(s) shall have a nominal flow rate capacity of ________ GPM/GPH at ________°F rise with rated input of _____________ BTU/hr. Water heater(s) shall be vented with 2“ Schedule 40/80 PVC/CPVC, approved polypropylene and stainless steel vent pipe at a distance not to exceed 75’ (or equivalent) with each elbow equal to 8’ of pipe length or 3” Schedule 40/80 PVC/ CPVC, approved polypropylene and stainless steel vent pipe at a distance of 150’ (or equivalent) with each elbow equal to 5’ of pipe length. Water heater(s) is rated for 150 PSI working water pressure and 300 PSI test pressure. Gas supply pressure shall be 3.5" to 10.5” WC for natural gas and 8.0“ to 13.0” WC for propane. Unit(s) shall have a steel case, dual stainless steel heat exchangers, eco premixed burner, negative pressure gas valve, dual venturi, 3/4” inlet gas connection, 3/4” brass inlet/outlet water connections, water holding capacity of 0.6 gallons for the NPE-150S2, 1.0 gallon for the NPE-180A2 model (0.7 gallons for NPE-180S2 model), 1.2 gallons for the NPE-210A2/NPE-240A2 models (0.7 and 0.9 gallons for NPE-210S2 and NPE-240S2 models respectively), and a condensate collector. The NPE-180A2 model weighs 73 lbs (NPE-180S2 weighs 68 lbs), and the NPE-210A2/NPE-240A2 models weigh 77 lbs (NPE-210S2 and NPE-240S2 weigh 73 lbs) and the NPE-150S2 weigh 62lbs. Unit(s) shall include features such as an adjustment for installations at high elevation, temperature lockout, and temperature options from 97-120°F in 1°F intervals and 120-140°F in 1°F intervals. The unit(s) shall include additional temperature options of 140-185°F in 1°F intervals, for high temperature commercial applications. All NPE “A2” models shall include an internal circulation pump and 0.5-gallon buffer tank. The water heater(s) shall be controlled by an internal circuit board that monitors the inlet and outlet temperatures with installed thermistors, sensing and controlling flow rate to set point temperature with air-fuel ratio controls in order to maintain thermal combustion efficiency. Unit(s) shall include safety features such as flame sensor system, high limit sensors, overheat prevention device, freeze protection mode, and fan motor rotation detector. Multi- system (cascade) applications that require 2 to 32 units shall be installed by connecting the units using cable only connections (Ready Link). The water heater(s) exceeds the energy efficiency requirements of ASHRAE 90.1-2010 and is listed by SCAQMD Rule 1146.2 (Type 1) as compliant with Rule 1146.2 (Type 1) for Ultra Low NOx requirements of 14 ng/J or 20 ppm @ 3% O2. * Navien reserves the right to change specifications at any time without prior notice Navien, Inc. 20 Goodyear, Irvine, CA 92618 Ph: (949)420-0420 Fax: (949)420-0430 www.NavienInc.com 1-NPE2-SS-001-1.1 Permit #: 6694 Permit Date: 09/03/25 Permit Type: RESIDENTIAL PLUMBING Project Name: DO PLUMB PERMIT Applicant Name: CM HEATING Applicant Address: 1500 INDUSTRY ST #200 Applicant, City, State, Zip: EVERETT Contact: SABRINA KENNARD Phone: 4252590550 Email: PERMITS@CMHEATING.COM Scope of Work: WHOLE HOME REPIPE+TANKLESS Valuation: 18112.00 Square Feet: 1173 Number of Stories: 1 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 09/04/2025 Permit Expires: 03/03/2026 Form Permit Type: RESIDENTIAL PLUMBING Status: COMPLETE Assigned To: Kristin Foster Property Parcel # Address Legal Description Owner Name Owner Phone Zoning 105 SINGLE- 16519 40TH AVE NE UNIT 00866700015200 DO CHRISTOPHER FAMILY B152 CONDOMINIUMS Contractors Contractor Primary Contact Phone Address Contractor Type License License # 1500 INDUSTRY CONSTRUCTION Plumbing CM HEATING INC 425-259-0550 CMHEAHL750LP ST STE 200 CONTRACTOR Contractor 1500 INDUSTRY CONSTRUCTION Construction CM HEATING INC 425-259-0550 CMHEAHL751W ST STE 200 CONTRACTOR Contractor 1500 INDUSTRY CONSTRUCTION CM HEATING INC 425-259-0550 UBI 605890285 ST STE 200 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status AM NEEDED - R14. PLUMBING 02/03/2026 CHRISTOPHER 02/06/2026 02/04/2026 BUILDING Approved FINAL 4258794185 C08. PLUMBING 09/10/2025 09/15/2025 09/15/2025 BUILDING Completed ROUGH-IN Fees Fee Description Notes Amount Processing/Technology $25.00 Inspection $75.00 Bath/Shower Combo $30.00 Clothes Washer $15.00 Dishwasher $15.00 Hose Bib $30.00 Icemaker / Refrigerator $15.00 Lavatory Toilet & Sink Only $30.00 Plumbing Base Permit Fee $25.00 Sink (bar, service, etc.) $45.00 Toilets $30.00 Water Heater (Tankless) $25.00 Credit Card Service $10.80 Total $370.80 Attached Letters Date Letter Description 09/03/2025 Building Permit 09/03/2025 Web Form- Residential Plumbing Application Payments Date Paid By Description Payment Type Accepted By Amount 09/03/2025 Matt Zivanov 241948738 Hannah Hardwick $10.80 XBP Conf: 09/03/2025 $360.00 241948738 Outstanding Balance $0.00 Notes Date Note Created By: 02/02/2026 Expiration notice sent LaNay Hendrick 09/03/2025 All connections to be exposed for inspection. Inspection prior to cover. Call for inspection. Kristin Foster Uploaded Files Date File Name 09/04/2025 28122191-20250904_BLD6694_IssuedPermit.pdf 09/03/2025 d5e55c29e9b9b044ba44bc68414dfced_do_signed_app.pdf 09/03/2025 808feb209ae05254b69d2388ccba1dc3_npe-2_spec_sheet_0303023_00000002_6_.pdf