Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
8203 VALLEY VIEW DR_BLD6655_2026
MIRIAM CHAVEZ 7/3/2025 Submittal Split System Heat Pump 5A6H5024A1000A NNoottee:: “Graphics in this document are for representation only. Actual model may differ in appearance.†March 2024 55AA66HH55002244AA--SSUUBB--11AA--EENN Outline Drawing Model Base A B C D E F G H J K 832 829 756 127 76 197 60 508 5A6H5024A 3 3/4 5/16 (32–3/4) (32–5/8) (29–3/4) (5) (3) (7–3/4) (2–3/8) (20) Sound Power Level A-Weighted Sound Full Octave Sound Power(dB) MODEL Power Level [dB(A)] 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 5A6H5024A 71 77 72 68 68 69 60 53 47 Note: Rated in accordance with AHRI Standard 270–2008 *For Reference Only 2 5A6H5024A-SUB-1A-EN Product Specifications OUTDOOR UNIT(a) (b) 5A6H5024A1000A (a) Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program, which is based on AHRI standard POWER CONNS. – V/PH/HZ(c) 208/230/1/60 210/240. MIN. BRCH. CIR. AMPACITY 13 (b) Rated in accordance with AHRI standard 270. (c) Calculated in accordance with Natl. Elec. Codes. Use only HACR BR. CIR. PROT. RTG. – MAX. (AMPS) 20 circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on COMPRESSOR DURATION® - SCROLL this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit NO. USED – NO. STAGES 1 – 1 selection current. VOLTS/PH/HZ 208/230/1/60 (e) No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. R.L. AMPS(d) – L.R. AMPS 9.1 - 59.0 Optional kit shown. FACTORY INSTALLED (f) Standard Air – Dry Coil – Outdoor (g) This value approximate. For more precise value see unit nameplate. START COMPONENTS(e) NO (Uses BAYKSKT263) (h) Reference the outdoor unit ship-with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software INSULATION/SOUND BLANKET NO pub # 32-3312-xx or refrigerant piping application guide SS- APG006-xx for long line sets or specialty applications (xx denotes COMPRESSOR HEAT NO latest revision). OUTDOOR FAN PROPELLER (i) The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of DIA. (IN.) – NO. USED 23 – 1 tested connecting line, and the smallest rated indoor evaporative coil match. Always verify proper system charge via subcooling (TXV/EEV) TYPE DRIVE – NO. SPEEDS DIRECT – 1 or superheat (fixed orifice) per the unit nameplate. CFM @ 0.0 IN. W.G.(f) 2980 NO. MOTORS – HP 1 – 1/8 MOTOR SPEED R.P.M. 850 VOLTS/PH/HZ 208/230/1/60 F.L. AMPS 0.64 OUTDOOR COIL – TYPE SPINE FIN™ ROWS – F.P.I. 1 – 24 FACE AREA (SQ. FT.) 18.75 TUBE SIZE (IN.) 3/8 REFRIGERANT CONTROL EXPANSION VALVE REFRIGERANT LBS. – R-454B (O.D. UNIT)(g) 4 LBS., 10 OZ FACTORY SUPPLIED YES LINE SIZE – IN. O.D. GAS(h) (i) 3/4 LINE SIZE – IN. O.D. LIQ. 5/16 CHARGING SPECIFICATIONS SUBCOOLING 12°F DIMENSIONS H X W X D CRATED (IN.) 38.1 x 30 x 33 WEIGHT SHIPPING (LBS.) 208 NET (LBS.) 174 5A6H5024A-SUB-1A-EN 3 Mechanical Specification Options GGeenneerraall CCoommpprreessssoorr The outdoor condensing units are factory charged with The compressor features internal over temperature and the system charge required for the outdoor condensing pressure protection. Other features include: Centrifugal unit, ten (10) feet of tested connecting line, and the oil pump and low vibration and noise. smallest rated indoor evaporative coil match. This unit CCoonnddeennsseerr CCooiill is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are The outdoor coil provides low airflow resistance and matched with a wide selection of air handlers and efficient heat transfer. The coil is protected on all four furnace coils that are AHRI certified. The unit is certified sides by louvered panels. to UL 60335-2-40. Exterior is designed for outdoor LLooww AAmmbbiieenntt CCoooolliinngg application. As manufactured, this system has a cooling capacity to CCaassiinngg 55°F. The addition of an evaporator defrost control Unit casing is constructed of heavy gauge, galvanized permits operation to 40°F. The addition of an steel and painted with a weather-resistant powder evaporator defrost control with TXV permits low paint finish. The corner panels are prepainted. All ambient cooling to 30°F. panels are subjected to our 1,000 hour salt spray test. The addition of the BAYLOAM107A low ambient kit RReeffrriiggeerraanntt CCoonnttrroollss permits ambient cooling to 20°F. Refrigeration system controls include condenser fan, TThheerrmmoossttaattss – Cooling only and heat/cooling (manual compressor contactor and low and high pressure and automatic change over). Sub-base to match switches. A factory supplied, field installed liquid line thermostat and locking thermostat cover. drier is standard. 4 5A6H5024A-SUB-1A-EN About American Standard Heating and Air Conditioning American Standard has been creating comfortable and affordable living environments for more than a century. For more information, please visit www.americanstandardair.com. The AHRI Certified mark indicates company participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org. The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 5A6H5024A-SUB-1A-EN 14 Mar 2024 Supersedes (New) ©2024 American Standard Heating and Air Conditioning 9/3/2025 Permit #: 6655 Permit Date: 07/31/25 Permit Type: RESIDENTIAL MECHANICAL Project Name: Blackman Applicant Name: Seatown Electric Plumbing Heating and Air, LLC Applicant Address: 4200 78th St SW Applicant, City, State, Zip: Mukilteo, WA 98275 Contact: Miriam Chavez Phone: 206-848-5869 Email: miriamc@seatownservices.com Scope of Work: Heat pump replacement Valuation: 8500.00 Square Feet: 1302 Number of Stories: 1 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 09/03/2025 Permit Expires: 03/02/2026 Form Permit Type: RESIDENTIAL MECHANICAL Status: COMPLETE Assigned To: Kristin Foster Property Parcel # Address Legal Description Owner Name Owner Phone Zoning 100 SINGLE BLACKMAN 00910700007400 8203 VALLEY VIEW DR FAMILY LEONARD A RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License # SEATOWN ELETRIC 4200 78TH ST PLUMBING LABOR & PLUMBING HEATING 206.905.4946 SEATOEH7618M SW CONTRACTOR INDUSTRIES AND AIR SEATOWN ELETRIC 4200 78TH ST PLUMBING PLUMBING HEATING 206.905.4946 COA 603447624 SW CONTRACTOR AND AIR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status R15. 01/30/2026 MECHANICAL 02/03/2026 02/03/2026 BUILDING Approved FINAL Fees Fee Description Notes Amount Processing/Technology $25.00 Inspection $75.00 Heat Pump - Condensing Unit Enter # of units $25.00 Mechanical Base Permit Fee $25.00 Credit Card Service $4.50 Total $154.50 Attached Letters Date Letter Description 08/04/2025 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 08/01/2025 Seatown Electric 238927931 Hannah Hardwick $4.50 XBP Conf: 08/01/2025 $150.00 238927931 Outstanding Balance $0.00 Uploaded Files Date File Name 09/03/2025 28103947-20250903_BLD6655_IssuedPermit.pdf 07/31/2025 27608347-20250731_BLD6655_SitePlan 2.pdf 07/31/2025 27608020-20250731_BLD6655_SitePlan.png 07/31/2025 27608021-20250731_BLD6655_App.pdf 07/31/2025 27608022-20250731_BLD6655_Specs.pdf